Docket No: 50-219 OYSTER CREEK GENERATING STATION UNIT 1 Annual Radiological Groundwater Protection Program Report 1 January Through 31 December 2013 Prepared By Teledyne Brown Engineering Environmental Services

-" Exelon Generation.

Oyster Creek Generating Station Forked River, NJ 08731 April 2014

L.

Table of Contents I. Sum m ary and Conclusions .............................................................................................. 1 I1. Introduction ............................................................................................................. 3 A. O bjectives of the RG PP ................................................................................ 4 B. Im plem entation of the O bjectives .................................................................. 6 C. Program Description ....................................................................................... 6 D. Characteristics of Tritium (H-3) ...................................................................... 7 II1. Program Description ................................................................................................ 7 A. Sam ple Analysis ............................................................................................ 7 B. Data Interpretation .......................................................................................... 8 C. Background Analysis ..................................................................................... 9 IV. Results and Discussion ......................................................................................... 11 A. Program Exceptions ..................................................................................... 11 B. G roundwater Results ..................................................................................... 12 C. Surface Water Results ............................. ....... 13 D. Precipitation Water Results ......................................................................... 14 E. Summary of Results - Inter-laboratory Comparison Program ...................... 15 F. Leaks, Spills, and Releases ......................................................................... 15 G . T re n d s ...................................................................................... t ........................ 15 H. Investigations ................................................................................................ 15 I. Actions Taken ................................................................................................ 15 V. References ................................................................................................................... 16

Appendices Appendix A Location Designation Tables Table A-1 Radiological Groundwater Protection Program - Sampling Locations, Oyster Creek Generating Station, 2013 Figures Figure A-1 Sampling locations - Selected Cohansey and Cape May Formation Wells, Oyster Creek Generating Station, 2013 Security-Related Information: Detailed maps of the Oyster Creek Generating Station have been withheld from public disclosure under 10 CFR 2.390 and N.J.S.A. 47:1A-1.1 Appendix B Data Tables Tables Table B-I.1 Concentrations of Tritium, Strontium-89, Strontium-90, Gross Alpha and Gross Beta in Groundwater Samples Collected as Part of the Radiological Groundwater Protection Program, Oyster Creek Generating Station, 2013.

Table B-1.2 Concentrations of Gamma Emitters in Groundwater Samples Collected as Part of the Radiological Groundwater Protection Program, Oyster Creek Generating Station, 2013.

Table B-1.3 Concentrations of "Hard-To-Detects" in Groundwater Samples Collected as Part of the Radiological Groundwater Protection Program, Oyster Creek Generating Station, 2013.

Table B-II.1 Concentrations of Tritium, Strontium-89, and Strontium-90 in Surface Water Samples Collected as Part of the Radiological Groundwater Protection Program, Oyster Creek Generating Station, 2013.

Table B-11.2 Concentrations of Gamma Emitters in Surface Water Samples Collected as Part of the Radiological Groundwater Protection Program, Oyster Creek Generating Station, 2013.

Table B-11.3 Concentrations of "Hard-To-Detects" in Surface Water Samples Collected as Part of the Radiological Groundwater Protection Program, Oyster Creek Generating Station, 2013.

Table B-Ill.1 Concentrations of Tritium in Precipitation Water Samples Collected as Part of the Radiological Groundwater Protection Program, Oyster Creek Generating Station, 2013.

ii

Summary and Conclusions This report on the Radiological Groundwater Protection Program (RGPP) conducted for the Oyster Creek Generating Station (OCGS) by Exelon Generation Company LLC (Exelon) covers the period 01 January 2013 through 31 December 2013.

This report covers groundwater and surface water samples collected from the environment, both on and off station property in 2013. In 2013, 1,457 analyses were performed on 721 samples from 60 locations.

There were three inadvertent releases of contaminated water into the groundwater during 2009. There is a plume located west of the turbine building and is monitored via a series of monitoring wells.

Gamma-emitting radionuclide K-40 was detected in three of the 63 groundwater well samples. The concentrations ranged from 67 to 127 pCi/L. Potassium-40 was detected in 420 surface water samples. The concentrations ranged from 103 to 639 pCi/L.

In the case of tritium, Exelon specified that its laboratories achieve a lower limit of detection 100 times lower than the drinking water limit specified by the United States Environmental Protection Agency (USEPA) (200 pCi/I versus 20,000 pCi/I).

As expected, tritium was detected in groundwater samples. The 2013 Tritium concentrations varied from <200 to 73,300 pCi/l. The well with the highest concentration was MW-67. The flow of groundwater is in the direction of the intake and discharge canals.

No detectable tritium (greater than the MDC) was found in surface water or precipitation samples collected from onsite and offsite monitoring locations during 2013.

Strontium-89 and strontium-90 were not detected in any groundwater or surface water samples during 2013.

Gross Alpha and Gross Beta analyses in the dissolved and suspended fractions were performed on groundwater samples during the second quarter sampling in 2013.

There were 48 samples taken from 43 groundwater well locations. Gross Alpha (dissolved) was detected in 13 samples and ranged from 0.4 to 4.3 pCi/L. Gross Alpha (suspended) was detected in 17 samples and ranged from 0.9 to 35.1 pCi/L. Gross Beta (dissolved) was detected in 47 samples and ranged from 1.2 to 48.1 pCi/L. Gross Beta (suspended) was detected in 14 samples and ranged from 1.8 to 89 pCi/L.

"Hard-To-Detect" analyses were performed on a select group of groundwater locations to establish baseline levels. The analyses for groundwater included Fe-55, Ni-63, Am-241, Cm-242, Cm-243/244, Pu-238, Pu-239/240, U-234, U-235, and U-238. U-234 and U-238 were detected in one sample at a concentration of 0.35 pCi/L and 0.19 pCi/L, respectively. All other Hard-To-Detect analyses were less than the MDC. Occasionally the isotopes of U-234 and U-238 are detected and are considered background.

II. Introduction The Oyster Creek Nuclear Generating Station consists of a single boiling water reactor (BWR) and turbine generator capable of producing 650 megawatts of electricity. The Station operates under Nuclear Regulatory Commission (NRC) renewed facility operating license number DPR-16. Brackish water from Barnegat Bay is supplied to the circulating water system. The circulating water system is designed to supply a continuous flow of water from Barnegat Bay through the plant to remove the waste heat released by the power cycle in the Main Condenser. The circulating water system is comprised of the intake canal from Barnegat Bay to the plant, the Main Condenser Circulating Water System, the dilution plant, and the discharge canal to Barnegat Bay. The dilution plant portion of the system minimizes the adverse effects of hot discharge water on aquatic life in the discharge canal and Barnegat Bay to meet the conditions of the Oyster Creek New Jersey Pollutant Discharge Elimination system (NJPDES)

Permit No. NJ0005550. Approximately 1 million gallons per minute of water are withdrawn from the intake canal for dilution and station use and returned to the discharge canal.

The Station is located in the Atlantic Coastal Plain physiographic province.

Topography in the region of the Station is a slightly undulating coastal plain having low relief. The land surface gradually rises from sea level at Barnegat Bay, which is located east of the Station, to approximately 50 feet above mean sea level (AMSL) 2 miles inland. This region of the coastal plain has numerous tidal marshes and is incised by easterly flowing streams and creeks. Elevations at the Station property west of Route 9 range from approximately 0 to 15 feet AMSL immediately adjacent to the intake and discharge canals to slightly more than 30 feet AMSL in the northwest portion of the Station property. The 132-acre developed portion of the Site located within the "horseshoe" formed by the intake and discharge canals west of Route 9 has an approximate average elevation of 20 feet AMSL. In the immediate vicinity of the intake and discharge canals, the Station property slopes steeply down to the canal. The average elevation of the surface water level in the intake and discharge canals is approximately 1-foot AMSL. The remaining 637-acre portion of the Station located east of Route 9 is primarily vegetated and undeveloped. The ground surface is relatively level except for the steep slopes at areas adjacent to the intake and discharge canals.

The three shallowest stratigraphic units in the vicinity of the Oyster Creek area in descending order are the Cape May Formation, the Cohansey Formation, and the Kirkwood Formation. Some of the Station structures are constructed to depths of approximately 50 feet below ground surface (bgs). Excavations were completed from grade, through the fill, Cape May Formation, Upper Clay, and into the Cohansey Formation during construction. Consequently, the bottoms of some Station structures are completed within the Cohansey Formation and some structures breach the Upper Clay.

The Cape May Formation regionally has an average thickness of 40 feet and at OCGS, the Cape May is described as a light gray to tan, medium- to fine-grained sand, with trace to some silt and occasional coarse sand. It is generally poorly compacted. The Cape May Formation varies from 0 to 21 feet in thickness based on historical boring logs. The variation principally is due to the varying amount of material excavated and replaced by fill during Station construction.

When present, the thickness of the Cape May generally ranges from 15 to 20 feet thick. The base of the Cape May generally is defined by the presence of a dark clay unit referred to as the Upper Clay unit. The Upper Clay is a stiff to hard, gray, plastic organic clay containing inclusions (also described as lenses or partings) of dense fine sand with trace to some organic silt. The deposits of fine sand within the Upper Clay layer have high relative densities and occur as lenses or inclusions.

The Cohansey Formation is primarily composed of a light-colored, fine- to very coarse-grained quartzose sand with lenses of silt and clay. Although most borings at the Station do not penetrate the entire Cohansey Formation, this formation appears to be approximately 60 to 80 feet thick at OCGS. A clay sequence, referred to at the Station as the "Lower Clay", marks the base of the Cohansey, which generally is present to approximately 90 to 100 feet bgs. The lower clay is a dense gray medium- to fine-grained sand containing trace to some organic silt and layers or inclusions of very stiff to hard gray organic clay.

The thickness of the lower clay is estimated to be approximately 10 to 20 feet in the vicinity of OCGS.

The Cohansey Formation is underlain by the Kirkwood Formation which consists of several stratigraphic units. The Kirkwood Formation is described as a medium- to fine-grained sand with trace silt. The thickness of this formation beneath the Station is unknown. The south domestic supply well terminates in the Kirkwood at a depth of 310 feet bgs. The Kirkwood thickness in Ocean County ranges from approximately 300 to 400 feet.

This report covers those analyses performed by Teledyne Brown Engineering (TBE) and Environmental Inc. (Midwest Labs) on samples collected in 2013.

A. Objectives of the RGPP The long-term objectives of the RGPP are as follows:

  • Ensure that the site characterization of geology and hydrology provides an understanding of predominant ground water gradients based upon current site conditions.

" Identify site risk based on plant design and work practices.

" Evaluate all SSCs that contain or could contain licensed material and for which there is a credible mechanism for the licensed material to reach groundwater.

" Evaluate work practices that involve licensed material and for which there is a credible mechanism for the licensed material to reach groundwater.

" Perform on-site monitoring to ensure timely detection of inadvertent radiological releases to ground water.

" Understand background concentrations of radioactive analytes outside of the REMP, as required.

" Evaluate return/re-use of previously discharged radioactive effluents in gaseous or liquid effluents that are returned from the environment to the operating nuclear power facility.

" Ensure controls are established for the selection, installation and retirement of monitoring wells.

" Perform remediation protocols to prevent migration of licensed material off-site and to minimize decommissioning impacts.

" Ensure that records of leaks, spills, remediation efforts are retained and retrievable to meet the requirements of 10 CFR 50.75(g).

" Ensure periodic communications are held on the RGPP with the designated State/Local officials.

" Ensure timely verbal and written reporting occurs if there is an inadvertent release of licensed materials to the soil, groundwater or surface water.

" Document and report all applicable RGPP data.

" Identify and resolve deficiencies via the Corrective Action Process as delineated in PI-AA-120 "Issue Identification and Screening Process".

" Perform program oversight to ensure effective implementation of the voluntary RGPP.

B. Implementation of the Objectives The objectives identified have been implemented at the Oyster Creek Generating Station through compliance with approved procedures EN-AA-408-4000, Radiological Groundwater Protection Program Implementation and site specific procedure EN-OC-408-4160, RGPP Reference Material for Oyster Creek Generating Station.

C. Program Description Samples for the OCGS site were collected for Exelon by on-site personnel and Normandeau Associates, Inc. This section describes the general collection methods used to obtain environmental samples for the OCGS RGPP in 2013. Sample locations can be found in Table A-i, Appendix A.

1. Sample Collection Samples of water are collected, managed, transported and analyzed in accordance with approved procedures. Both groundwater and surface water are collected. Sample locations, sample collection frequencies and analytical frequencies are controlled in accordance with approved station procedures.

Contractor and/or station personnel are trained in the collection, preservation management, and shipment of samples, as well as in documentation of sampling events.

2. Sample Analysis Samples are analyzed in accordance with approved procedures that are based on industry standards.
3. Quality Control Analytical laboratories are subject to internal quality assurance programs, industry cross-check programs, nuclear industry audits, as well as being certified by the State of New Jersey.
4. Data Interpretation Station personnel review and evaluate all analytical data deliverables as data is received. Analytical data results are reviewed by both station personnel and independent consultants, including a hydrogeologist, for adverse trends or changes to hydrogeologic conditions.

D. Characteristics of Tritium (H-3)

Tritium (chemical symbol H-3) is a radioactive isotope of hydrogen. The most common form of tritium is tritium oxide, which is also called "tritiated water." The chemical properties of tritium are essentially those of ordinary hydrogen.

Tritiated water behaves the same as ordinary water in both the environment and the body. Tritium can be taken into the body by drinking water, breathing air, eating food, or absorption through the skin. Once tritium enters the body, it disperses quickly and is uniformly distributed throughout the body. Tritium is excreted primarily through urine with a clearance rate characterized by an effective biological half-life of about 10 days.

Tritium is produced naturally in the upper atmosphere when cosmic rays strike air molecules. Tritium is also produced during nuclear weapons explosions, as a by-product in reactors producing electricity, and in special production reactors. Also, tritium was released into the atmosphere from Chernobyl in 1986. Like normal water, tritiated water is colorless and odorless. Tritiated water behaves chemically and physically like non-tritiated water in the subsurface, and therefore tritiated water will travel at the same velocity as the average groundwater velocity.

Tritium has a half-life of approximately 12.3 years. It decays spontaneously to helium-3 (He-3). This radioactive decay releases a beta particle (18.6 keV low-energy electron). The radioactive decay of tritium is the source of the health risk from exposure to tritium. Tritium is one of the least dangerous radionuclides because it emits very weak radiation and leaves the body relatively quickly. Since tritium is almost always found as water, it goes directly into soft tissues and organs. The associated dose to these tissues is generally uniform and is dependent on the water content of the specific tissue.

Il1. Program Description A. Sample Analysis This section describes the general analytical methodologies used by TBE to analyze the environmental samples for radioactivity for the Oyster Creek Generating Station RGPP in 2013. The sampling frequencies are increased if activity is detected.

In order to achieve the stated objectives, the current program includes the following analyses for groundwater, surface water, and precipitation water:

1. Gamma emitters
2. Strontium-89 and Strontium-90
3. Tritium
4. Gross Alpha, Dissolved and Suspended and Gross Beta, Dissolved and Suspended
5. Selected transuranics
6. Fe-55
7. Ni-63 B. Data Interpretation The radiological data collected prior to Oyster Creek Generating Station becoming operational, as well as background data from publicly available databases, were used as a baseline with which these operational data were compared. For the purpose of this report, Oyster Creek Generating Station was considered operational at initial criticality. Several factors were important in the interpretation of the data:
1. Lower Limit of Detection and Minimum Detectable Concentration The lower limit of detection (LLD) is defined as the smallest concentration of radioactive material in a sample that would yield a net count (above background) that would be detected with only a 5% probability of falsely concluding that a blank observation represents a "real" signal. The LLD is intended as a before the fact estimate of a system (including instrumentation, procedure and sample type) and not as an after the fact criterion for the presence of activity. All analyses were designed to achieve the required OCGS detection capabilities for environmental sample analysis.

The minimum detectable concentration (MDC) is defined as the smallest concentration of radioactive material in a sample that would yield a net count (above background) that would be detected with only a 5% probability of falsely concluding that a blank observation represents a "real" signal as an after the fact estimate of the presence of activity.

2. Laboratory Measurements Uncertainty The estimated uncertainty in measurement of tritium in environmental samples is frequently on the order of 50% of the measurement value.

Statistically, the exact value of a measurement is expressed as a range with a stated level of confidence. The convention is to report results with a 95% level of confidence. The uncertainty comes from calibration standards, sample volume or weight measurements, sampling uncertainty and other factors. Exelon reports the uncertainty of a measurement created by statistical process (counting error) as well as all sources of error (Total Propagated Uncertainty or TPU). Each result has two values calculated. Exelon reports the TPU by following the result with plus or minus (+/-) the estimated sample standard deviation, as TPU, that is obtained by propagating all sources of analytical uncertainty in measurements.

Analytical uncertainties are reported at the 95% confidence level.

C. Background Analysis

1. Background Concentrations of Tritium The purpose of the following discussion is to summarize background measurements of tritium in various media performed by others. Additional detail may be found by consulting references.
a. Tritium Production Tritium is created in the environment from naturally occurring processes both cosmic and subterranean, as well as from anthropogenic (i.e., man-made) sources. In the upper atmosphere, "cosmogenic" tritium is produced from the bombardment of stable nuclides and combines with oxygen to form tritiated water, which will then enter the hydrologic cycle. Below ground, "lithogenic" tritium is produced by the bombardment of natural lithium present in crystalline rocks by neutrons produced by the radioactive decay of naturally abundant uranium and thorium. Lithogenic production of tritium is usually negligible compared to other sources due to the limited abundance of lithium in rock. The lithogenic tritium is introduced directly to groundwater.

A major anthropogenic source of tritium and strontium-90 comes from the former atmospheric testing of thermonuclear weapons. Levels of tritium in precipitation increased significantly during the 1950s and peaked in 1963 with the signing of the limited test ban treaty. The Canadian heavy water nuclear power reactors, other commercial power reactors, nuclear research and weapons production continue to influence tritium concentrations in the environment. Also, tritium was released into the atmosphere from Chernobyl in 1986.

b. Precipitation Data Precipitation samples are routinely collected at stations around the world for the analysis of tritium and other radionuclides. One publicly available database that provides tritium concentrations in precipitation is the USEPA's RadNet database. RadNet provides tritium precipitation concentration data for samples collected at stations throughout the U.S. from 1978 up to and including 1996.

Tritium concentrations in precipitation in New Jersey from 1978 through 1996 have ranged from 600 pCi/I in 1979 to 0 pCi/I in 1996, with an average of 185 pCi/l. Tritium concentrations in wells may still be above the 200 pCi/I detection limit from the external causes described above.

Water from previous years and decades is naturally captured in groundwater, so some well water sources today are affected by the surface water from the 1960s that was elevated in tritium.

c. Surface Water Data Tritium concentrations are routinely measured in surface water bodies, including Oyster Creek and the Delaware River. New Jersey surface water data between 1978 and 1998 averaged 185 pCi/l.

The USEPA RadNet surface water data typically has a reported 'Combined Standard Uncertainty' of 2 standard deviations. This corresponds to a +/- 36 to +/-100 pCi/I confidence bound on each given reported measurement so that the typical surface water background data provided by RadNet may be subject to measurement uncertainty of up to 100 pCi/I.

The radio-analytical laboratory counts tritium results to an Exelon specified LLD of 200 pCi/I with a typical uncertainty of +/-100 pCi/I. Therefore, sample results reported by TBE near this LLD can not be distinguished from natural background concentrations in surface water.

IV. Results and Discussion A. Program Exceptions

1. Sample Anomalies There are no sample anomalies in 2013.
2. Missed Samples Exelon maintains a Radiological Groundwater Protection Program (RGPP) as part of the nuclear industry's voluntary groundwater protection initiative as described in NEI 07-07. As part of this program, samples are obtained routinely from monitoring wells and surface waters at Oyster Creek based on the frequencies outlined in station procedures. The following samples were not obtained as required by procedure:

MW-51

- Tritium, monthly

- Gamma, semi-annually

- Gross alpha, annually

- Gross beta, annually

- Select transuranics, annually

- Iron-55, annually

- Nickel-63, annually

- Strontium-89, annually

- Strontium-90, annually Immediate actions taken:

MW-51 was dry 12 out of 12 months during sampling events. MW-51 is checked for water each sampling event and no additional actions are required.

3. LLDs Not Met Required LLDs for Surface and Groundwater Isotope pCi/liter H-3 200 Mn-54 15 Co-58 15 Fe-59 30 Co-60 15 Zn-65 30 Nb-95 15 Zr-95 30 1-131 15 Cs-134 15 Cs-137 18 Ba-140 60 La-140 15 Pu-241 50 Fe-55 200 Ni-63 5 Sr-89 10 Sr-90 1 Gross Alpha (diss) 3 Gross Alpha (susp) 10 Gross Beta (diss) 4 Gross Beta (susp) 4 Transuranics 0.2 Indicated LLDs for shorter lived radionuclides were not met due to a time lag between taking the samples and analyzing the samples as indicated on table B-1.2 and B-11.2.

B. Groundwater Results Samples were collected from on-site locations in accordance with the station radiological groundwater protection program. As reported in CRA's 2011 Hydrogeologic Investigation Report, groundwater flow in the vicinity of the Torus Water Storage Tank and the Condensate Storage Tank is towards the intake and discharge canals.

Tritium Samples from 51 locations were analyzed for tritium activity (Table B-I.1, Appendix B). Tritium was detected in 52 of 245 samples.

The values ranged from < 200 to 73,300 pCi/I. The well with the highest concentration was MW-67 (Table B-1. 1, Appendix B).

Strontium Strontium-89 and strontium-90 were not detected in any location sampled in 2013. (Table B-1.1, Appendix B)

Gross Alpha and Gross Beta (dissolved and suspended)

Gross Alpha and Gross Beta analyses in the dissolved and suspended fractions were performed on groundwater samples during the second sampling in 2013.

There were 48 samples taken from 43 groundwater well locations.

Gross Alpha (dissolved) was detected in 13 samples and ranged from 0.4 to 4.3 pCi/L. Gross Alpha (suspended) was detected in 17 samples and ranged from 0.9 to 35.1 pCi/L. Gross Beta (dissolved) was detected in 47 samples and ranged from 1.2 to 48.1 pCi/L. Gross Beta (suspended) was detected in 14 samples and ranged from 1.8 to 89 pCi/L.

Gamma Emitters Gamma emitting nuclide K-40 was detected in three of 63 samples analyzed during 2013. The concentrations ranged from 67 to 127 pCi/L. (Table B-1.2, Appendix B).

"Hard-To-Detect" "Hard-To-Detect" analyses were performed on a select group of groundwater locations to establish background levels. The analyses for groundwater included Fe-55, Ni-63, Am-241, Cm-242, Cm-243/244, Pu-238, Pu-239/240, U-234, U-235, and U-238.

U-234 and U-238 were detected in one sample at a concentration of 0.35 pCi/L and 0.19 pCi/L, respectively. All other Hard-To-Detect analyses were less than the MDC. Occasionally the isotopes of U-234 and U-238 are detected and are considered background (Table B-1.3, Appendix B).

C. Surface Water Results Samples were collected from on-site locations in accordance with the station radiological groundwater protection program. Analytical results and anomalies are discussed below.

Tritium Samples from 4 locations were analyzed for tritium activity (Table B-II.1, Appendix B). No detectable tritium (greater than the LLD) was found in any surface water samples collected from onsite and offsite monitoring locations.

Strontium Strontium was not detected in 2013.

Gross Alpha and Gross Beta (dissolved and suspended)

Gross Alpha and Gross Beta analyses in the dissolved and suspended fractions are not required on a routine basis and were not analyzed in 2013.

Gamma Emitters Gamma emitting nuclide, naturally occurring potassium-40, was detected in the samples analyzed. (Table B-11.2, Appendix B)

'Hard-To-Detect" "Hard-To-Detect" analyses are not required on a routine basis and were not analyzed in 2013.

D. Precipitation Water Results Precipitation samples were collected from onsite and offsite locations in accordance with the station radiological groundwater protection program. Analytical results and anomalies are discussed below.

Tritium Samples from five locations were analyzed for tritium activity (Table B-Ill.1, Appendix B). No detectable tritium (greater than the LLD) was found in any precipitation water samples collected from onsite and offsite monitoring locations.

E. Summary of Results - Inter-Laboratory Comparison Program Inter-Laboratory Comparison Program results for TBE and Environmental Inc. (Midwest Labs) are presented in the 2013 Oyster Creek AREOR.

This report is part of the AREOR F. Leaks, Spills, and Releases There were no abnormal releases during 2013.

G. Trends Active remediation of tritium in groundwater due to the spills that occurred in 2009 was initiated in October 2010. Trending of the data due to active remediation is on-going. Overall the station has seen a decreasing trend in tritium values.

H. Investigations Conestoga Rovers and Associates performed an independent assessment of the tritium plume. The results of their assessment can be found in References 2 and 3.

1. Actions Taken
1. Compensatory Actions Active remediation of tritium in groundwater due to the spills that occurred in 2009 was initiated in October, 2010.
2. Installation of Monitoring Wells The following wells were installed in 2010 to better characterize and monitor the tritium plume and site hydrology.

Well Number Formation Well Installation Date W-581 Cohansey July W-591 Cohansey March W-601 Cohansey July W-61 I Cohansey July W-62 Cape May March W-63 I Cohansey July W-64 Cape May March W-65 Cape May March W-661 Cohansey July Well Number Formation Well Installation Date W-67 Cape May March W-681 Cohansey July W-691 Cohansey July W-701 Cohansey July W-71 Cape May August W-72 Cape May August W-73 Pumping well Cohansey October

3. Actions to Recover/Reverse Plumes Oyster Creek Generating Station is currently addressing the tritium in groundwater through pumping of groundwater out of W-73 into the intake structure.

V. References

1. Conestoga Rovers and Associates, Hydrogeologic Investigation Report, Fleetwide Assessment, Oyster Creek Generating Station, Forked River, New Jersey, Ref. No. 055875 (6), April 2011
2. Conestoga Rovers and Associates, Site Investigation Report, Oyster Creek Generating Station, Forked River, New Jersey, Ref. No. 055875 (4), August 2009
3. Conestoga Rovers and Associates, Remedial Investigation Workplan, Oyster Creek Generating Station, Forked River, New Jersey, Ref. No. 055875 (5),

October 2009 APPENDIX A LOCATION DESIGNATION

TABLE A-1: Radiological Groundwater Protection Program - Sampling Locations, Oyster Creek Generating Station, 2013 Oyster Creek Generating Station RGPP Sample Point List Well GPS RGPP Tritium Aquifer or Sample Identification Location Coordinates Depth Sample Alert Water Number (Northing/Easting) (ft) Point Value Body Designation Monitored North 358373.33 2,000 DWN Domestic 574672.98 300.0 B pCi/L Kirkwood Well South DWS Domestic 356955.90 145.0 B 2,000 Kirkwood WellWel574616.69 pCi/L E of ISFSI LW-- 357632.49 21.0 2,000 Cape May (microwave 575569.96 pCi/L zone)

E of ISFSI LW-2 357645.30 21.0 2,000 Cape May (microwave 575581.92 pCi/L zone)

E of ISFSI

- 357630.20 21.0 D 2000 Cape May LW-3 (microwave 575575.52 pCi/L zone)

East of ISFSI - 357652.78 49.0 D 2,000 Cohansey LW-4 (microwave 575573.75 pCi/L zone)

SW of 357380.76 2,000 MW-1A-2A MFOT 575043.44 24.0 D pCi/L Cape May moat East of 358551.94 2000 MW-1G-1A fueling 575308.91 20.0 1 p~i/L Cape May station East of 358550.57 45.0 2,000 Cohansey Mst-1G-1B fueling 575316.19 pCi/LL station Roadway - 357598.17 2000 MW-11-1A NW of 574412.70 19.0 D 2,000 Cape May TWSTof pCi/L Roadway - 357574.80 2,000 MW-1 I-2A SE of 17.5 Cape May TWST 574493.50 pCi/L MW-15K-1A Roadway - 357297.90 190 D 2,000 Intake 574469.50 . pCi/L Cape May Yard - W 357573.30 2000 MW-16D B574746.50 of MAC Building 57765pi/ 25.0 Cape May A-1

TABLE A-1 : Radiological Groundwater Protection Program - Sampling Locations, Oyster Creek Generating Station, 2013 Oyster Creek Generating Station RGPP Sample Point List Sample Well GPS Depth RGPP Tritium Aquifer or Identification Location Coordinates Sample Water (Northing/Easting) (ft) Point Alert Body Number Designation Value Monitored Finninger 2000 MW-24-2A Farm - 356838.52 18.0 Cape May near DSB 579470.94 pCi/L Finninger 356828.49 2,000 MW-24-3A Farm - 17.0 pCi/L Cape May near DSB 578969.05 17.0L Main MCD Condenser N/A N/A Weekly* H-3 2,000 Surface Discharge pCi/L Water SW-iSW1 Intake Canal N/A NA/AH-3 N/A SWNVeekly* 2,000 Surface pCi/L Water RT 9 2,000 Surface SW-2 South N/A N/A SW pCi/L2 Water Bridge SW-3 Fire Pond N/A N/A SW 2,000 Surface pCi/L Water Dilution W-1 Pump 357029.86 50.0 2,000 Cohansey Area - 574140.61 pCi/L West Bank W-1A North Yard 358311.70 50.0 2,000 Area 574679.00 pCi/L Cohansey W-1 B North Yard 358312.80 20.0 1 2,000 Cape May Area 574685.40 pCi/L West end 357149.22 60.0 2,000 W-1C of backsite 572741.00 pCi/L Cohansey W-1K West end 357151.55 150.0 2,000 Kirkwood of backsite 572728.77 pCi/L W-2 S of EDG 356965.65 57.0 2,000 Cohansey Bldg 574555.73 pCi/L Field - W 358105.00 2,000 W-2A of North 574348.60 50.0 pCi/L Cohansey Yard Bldg A-2

TABLE A-1 : Radiological Groundwater Protection Program - Sampling Locations, Oyster Creek Generating Station, 2013 Oyster Creek Generating Station RGPP Sample Point List Sample Well GPS RGPP Aquifer or Identification Location Coordinates Depth Sample Tritium Water Number (Northing/Easting) (ft) Point Alert Body Designation Value Monitored W-2B Field- Wf 358110.30 2,000 North Yard 574348.50 20.0 B pCi/L Cape May Building W-2C Forked 357923.67 60.0 2,000 River CT 573809.92 pCi/L Cohansey Site Forked 358030.88 150.0 2,000 W-2K River CT 573762.54 pCi/L Kirkwood Site W-3 Intake - 357173.00 24.0 D 2,000 Access 574499.10 pCi/L Cape May Road PlantCo W-3A 358067.92 50.0 2,000 W-3A Access 575664.22 pCi/L Cohansey Road Plant 358070.58 2,000 W-31 Access 575656.25 20.0 1 pCi/L Cape May Road Finninger 356595.30 60.0 2'000 W-3C Farm - N of 576663.33 Cohansey Discharge 5766L3Cohansey Finninger 356602.17 2,000 W-3K Farm ishre

- N of 576675.04 100.0 pCi/L Kirkwood Discharge Intake - 357176.40 2,000 W-4 Access 574497.70 55.0 D p/ Cohansey Road SE of 356913.30 W-4A OCAB 575387.10 50.0 B 2,000 Coh Building pCi/L ansey SE of W-4B OCAB 356916.40 20.0 B 2,000 Cape May Building 575388.90 pCilL W-4C~ FinningerCo Farmi-S of 359305.61 60.0 2,000 Farm - S of 575867.58 pCi/L Cohansey Finninger 359321.83 2,000 W-4K Farm - S of 575874.07 100.00 piL Kirkwood Intake A-3

TABLE A-1: Radiological Groundwater Protection Program - Sampling Locations, Oyster Creek Generating Station, 2013 Oyster Creek Generating Station RGPP Sample Point List Sample WelGS Well GPS Depth Sample RGPP Tritium Aquifer or Identification Location Coordinates Deth Sampl Trt Water (Northing/Easting) Designation Value Body Number Monitored NW Yard W-5 area, near Fire Water 357510.95 574374.05 20.5 D Cape May pCi/L Tank Finninger Farm - E 356758.59 60.0 B 2,000 Cohansey W-5C of dredge 580642.26 pCi/L spoils Finninger W-5K Farm - E 356743.81 150.0 B 2,000 Kirkwood of dredge 580646.48 pCi/L spoils NW Yard -

W-6 near Fire 357514.02 52.0 D 2,000 Cohansey Water 574373.77 pCi/L Tank Builing 57713.8 200 D2,000 W-7W7 Building NE- 4 574713.08 357074.46 20.0 D pCi/L Cape May Roadway - 357289.29 2000 W-9 NE of SAS 574892.74 20.0 D p0i/L Cape May Building NW of SAS 357286.29 60.0 D 2,000 Cohansey W-10 Building 574890.61 pCi/L Yard - NW 357669.10 2,000 W-12 of DWPC 574755.60 20.0 D Cape May Building Yard - NW 357666.00 50.0 D 2000 Cohansey W-13 of DWPC 574755.90 pCi/L Building Yard - SW 357702.41 2,000 Warehouse 575018.75 53.0 D pCi/L Cohansey Warehouse Yard - SW 357705.83 2,000 W-15 of 575017.70 20.0 D pCi/L Cape May Warehouse W-16 Yard - E of 357967.26 20.0 D 2,000 Cape May LLRW 574933.03 pCi/L W-17 Road/ Exit 358078.05 150.0 2,000 Kirkwood Near W-3A 575667.14 pCi/L A-4

TABLE A-1: Radiological Groundwater Protection Program - Sampling Locations, Oyster Creek Generating Station, 2013 Oyster Creek Generating Station RGPP Sample Point List GPS R PWell T Aquifer or Identification Number Location Coordinates Depth Sample riiu Water (Northing/Easting) (ft) Point Alert Body Designation Value Monitored Near 357005.78 2,000 W-18 EDG 574621.620.0 Cape May Building pCi/L Near 357077.912,000 W-19 EDG 3570 20.0 pCi/L Cape May Building 574633.23 22, Ce SW of 356927.46 2,000 W-20 EDG 574542.59 20.0 1 pCi/L Cape May Building Near 357009.152,000 W-21 EDG 574518.22 20.0 1 2,000 Cape May Building pCi/L Near 357024.50 2,000 W-22 EDG 574590.19 39.0 1 pCi/L Cape May Building Near 357054.89 2,000 W-23 EDG 574564.88 20.0 1 P6i/L Cape May Building South of TB TB357128.94 2,000 W-24 W of old 574650.77 19.0 D p2i/L Cape May Machine Shop Near 356962.59 2,000 W-25 EDG 574677.59 20.0 1 P6i/L Cape May Building Near 357006.60 2,000 W-26 EDG 574644.03 20.0 1 pCi/L Cape May Building Near 357042.43 W-27 EDG 574.20.0 2,000 Cape May Building 574636.35 pCi/L Near 356991.29 2,000 W-28 EDG 574573.64 19.5 1 pCi/L Cape May Building Near 357012.62 2,000 W-29 EDG 574568.69 19.5 1 pCi/L Cape May Building Near 357058.00 1.000 W-30 EDG 575.19.5 2,000 Cape May Building 574516.71 pCi/L A-5

TABLE A-1: Radiological Groundwater Protection Program - Sampling Locations, Oyster Creek Generating Station, 2013 Oyster Creek Generating Station RGPP Sample Point List Sample Well GPS Coodiats Depth RGPP Sample Tritium Aquifer or Identification Location Coordinates Water Number (Northing/Easting) (ft) Point Designation Alert Body Value Monitored W-31 Near EDG 357051.78 19.5 1 2,000 Cape May Building 574495.62 pCi/L W-32 Near EDG 356978.58 19.5 1 2,000 Cape May Building 574528.44 pCi/L W-33 Near EDG 357026.93 19.5 1 2000 Cape May Building 574499.17 pCi/L South of TB 32,000 W-34 W of old 357196.14 40.0 D p~i/L Cohansey Machine Shop Between MW-50 CST and Intake 357368.21 574436.80 20.0 E 2,000 pCi/L Cape May Structure MW-51 Near CST 357378.30 574480.80 20.0 2,000 pCi/L Cape May Near MW-52 Intake 357400.90 20.0 D 2,000 Cape May Structure 7 pCi/L Near end MW-53 of CW 357272.80 20.0 D 2000 Cape May discharge 574447.60 pCi/L piping Near 357276.20 MW-54 Intake 574311.70 20.0 ECape May Structure 574311CapepMay Between MW-55 CST and Intake 357354.88 574440.07 30.0 E 2,000 pCi/L Cape May Structure MW-561 Bytanks NaOCI 357305.30 574465.50 52.0 2,000 pCi/L Cohansey NearNer 357343.71 2,000 MW-571 Intake 574373.89 50.0 pCi/L Cohansey Structure Near 357346.70 2000 MW-581 Intake 574377.28 72.0 D Cohansey Structure 57437.28ansey A-6

TABLE A-1 : Radiological Groundwater Protection Program - Sampling Locations, Oyster Creek Generating Station, 2013 Oyster Creek Generating Station RGPP Sample Point List Well GPS Tt Aquifer or Identification Location Coordinates Depth Sample riium Water Number (Northing/Easting) (ft) Point Alert Body Designation. Value Monitored Intake MW-591 Roadway 357422.14 44.0 2000 Cohansey

- NW of 574406.38 pCi/L CST MW-601 Near Intake 357346.55 2,000 Structure 574373.88 92.0 D pCi/L Cohansey Between MW-611 CST and 357328.64 72.0 2000 Cohansey Intake 574444.45 pCi/L Structure NW MW-62 Corner of 357467.93 2,000 Turbine 574524.10 25.0 0 pCi/L Cape May Bldg Between MW-631 CST and 357329.40 2,000 Intake 574447.67 92.0 0 pCi/L Cohansey Structure Near 357343.96 MW-64 Intake 574377.88 25.0 E2,00 Cape May Structure p74377CapepMay Intake MW-65 Roadway 357421.00 25.0 D 2,000 Cape May

- NW of 574402.55 pCi/L CST SE of MW-661 Reactor 357320.44 80.0 D 2,000 Bldg 574889.18 pCi/L Cohansey West side 357401.99 2,000 MW-67 of Turbine 574540.38 25.0 E pCi/L Cape May Bldg SE of MW-681 Reactor 357323.83 100.0 D 2,000 Coh Bldg 574897.64 pCi/L ansey Yard -

NW of 357664.03 78.0 2000 Cohansey MW-691 DWPC 574760.93 pCi/L Building Yard -

NW of 357670.57 2,000 MW-701 DWPC 574759.18 98.0 pCi/L Cohansey Building S of 357365.52 2000 MW-71 Reactor 574841.89 25.0 D p2i/L Cape May Bldg A-7

TABLE A-1: Radiological Groundwater Protection Program - Sampling Locations, Oyster Creek Generating Station, 2013 Oyster Creek Generating Station RGPP Sample Point List Sample WelGS Well GPS Depth Sample RGPP Tritium Aquifer or Location Coordinates Water Identification Number (Northing/Easting) (ft) Point Alert Body Designation Value Monitored MW-72 N of Reactor 357549.87 2,000 Bldg 574788.52 25.0 pCi/L Cape May MW-73 Remediation Rem N/A N/A N/A N/A N/A System

  • Tritium sampling freequency based upon agreement made with the NJDEP on 4/26/13.

D = Daily W = Weekly M = Monthly S = Semi-annual B = Biennial A-8

I .

L -

w-¶Ke WIC r

I' Figure A-1 Sampling Locations - Selected Cohansey and Cape May Formation Wells, Oyster Creek Generating Station, 2013 A-9

Figure A-I Sampling Locations - Selected Cohansey and Cape May Formation Wells, Oyster Creek Generating Station. 2013 A-J0

APPENDIX B DATA TABLES

TABLE B-I.1 CONCENTRATIONS OF TRITIUM, STRONTIUM-89, STRONTIUM-90, GROSS ALPHA AND GROSS BETA IN GROUNDWATER SAMPLES COLLECTED AS PART OF THE RADIOLOGICAL GROUNDWATER PROTECTION PROGRAM, OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA COLLECTION SITE DATE H-3 Sr-89 Sr-90 Gr-A (Dis) Gr-A (Sus) Gr-B (Dis) Gr-B (Sus)

LW-3 01109/13

  • 166 LW-3 04/10/13
  • 177 < 0.3 1.2 +/- 0.8 < 0.8 < 1.7 LW-3 07/18/13
  • 157 LW-3 10/15/13
  • 156 LW-3 12/18/13 < 4.5 < 0.7 LW-4 01/09/13 < 178 LW-4 04/10/13
  • 177 < 0.3 < 0.6 1.4 +/- 0.5 < 1.6 LW-4 07/18/i13
  • 166 LW-4 10/15/13
  • 156 LW-4 12/18/13 < 6.2 < 0.9 MW-15K-lA 01/08/13
  • 171 MW-15K-IA 02/12/13
  • 173 MW-15K-1A 03/05/13
  • 164 MW-15K-1A 04/09/13
  • 158 < 7.8 < 0.9 < 0.6 1.2 +/- 0.7 3.2 +/- 0.8 < 1.7 MW-15K-iA 07/11/13
  • 196 MW-15K-1A 10/08/13
  • 193 MW-16D 01/09/13
  • 187 MW-16D 04/10/13
  • 180 < 1.9 < 0.6 11.7 +/- 1.6 < 1.6 MW-16D 07/17/13
  • 175 MW-16D 10/11/13
  • 190 MW-16D 12/17/13 < 6.0 < 0.7 MW-1A-2A 01/09/13
  • 177 MW-1A-2A 04/10/13
  • 176 < 0.8 <0.7 3.3 +/- 0.9 < 1.6 MW-1A-2A 07/17/13
  • 187 MW-1A-2A 10/15/13
  • 159 MW-1A-2A 12/18/13 < 5.6 < 0.8 MW-11-1A 01/08/13
  • 191 MW-11-1A 04/09/13
  • 179 0.9 +/- 0.4 1.1 +/- 0.7 2.9 +/- 0.7 6.0 +/- 1.4 MW-11-1A 07/17/13
  • 172 MW-11-1A 10/11/13 < 186 MW-11-1A 12/17/13 < 5.1 < 0.7 MW-1 I-2A 01/08/13
  • 177 MW-1 I-2A 04109/13
  • 179 <0.5 < 1.0 1.3 +/- 0.6 < 1.7 MW-1 1-2A 07/17/13
  • 176 MW- 11-2A 10/11/13
  • 190 MW- 1I-2A 12/17/13 < 5.2 < 0.6 MW-50 01/08/13 TBE 17200 +/- 1760 MW-50 01/08/13 TBE 16400 +/- 1680 MW-50 01/08/13 EIML 17112 +/- 369 MW-50 02/12/13 15300 +/- 1570 MW-50 03/05/13 8780 +/- 918 MW-50 04/08/13 TBE 9100 +/- 954 < 4.5
  • 0.7
  • 0.7 1.4 +/- 0.8 4.5 +/- 0.9 < 1.7 MW-50 04/08/13 TBE 8740 +/- 919 < 4.9
  • 0.9 <0.7 <1.1 4.8 +/- 0.9 3.1 +/- 1.3 MW-50 04/08/13 EIML 8558 +/- 270
  • 0.8 <0.5 MW-50 07/10/13 7950 +/- 841 MW-50 10/08/13 TBE 12700 +/- 1330 MW-50 10/08/13 TBE 10500 +/- 1090 MW-50 10/08/13 EIML 12974 +/- 333 MW-52 01/08/13
  • 163 MW-52 02/12/13
  • 174 MW-52 03/05/13
  • 166 MW-52 04/09/13
  • 156 < 0.7 < 0.4 12.7 +/- 1.2 5.9 +/- 1.5 B-I

TABLE B-I.1 CONCENTRATIONS OF TRITIUM, STRONTIUM-89, STRONTIUM-90, GROSS ALPHA AND GROSS BETA IN GROUNDWATER SAMPLES COLLECTED AS PART OF THE RADIOLOGICAL GROUNDWATER PROTECTION PROGRAM, OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA COLLECTION SITE DATE H-3 Sr-89 Sr-90 Gr-A (Dis) Gr-A (Sus) Gr-B (Dis) Gr-B (Sus)

MW-52 07/09/13

  • 172 MW-52 10/09/13
  • 189 MW-52 12/17/13 < 5.2 < 0.8 MW-53 01/09/13
  • 165 MW-53 02/12/13
  • 176 MW-53 03/05/13
  • 166 MW-53 04/09/13
  • 161 < 0.5 < 0.4 4.9 +/- 0.8 < 1.7 MW-53 07/11/13
  • 196 MW-53 10/08/13
  • 189 MW-53 12/18/13 < 6.3 < 0.6 MW-54 01/08/13
  • 166 MW-54 02/12/13
  • 174 MW-54 03/05/13
  • 175 MW-54 04/09/13
  • 158 < 7.3 < 0.7 < 1.8 2.0 +/- 1.1 48.1 +/- 2.4 5.9 +/- 1.8 MW-54 07/10/13 378 t 142 MW-54 10/08/13
  • 191 MW-55 01/08/13 1680 +/- 217 MW-55 02/12/13 584 +/- 136 MW-55 03/05/13 917 +/- 148 MW-55 04/08/13 1200 +/- 178 < 8.1 < 1.0 < 0.7 < 0.9 7.8 +/- 1.2 < 1.6 MW-55 07/11/13 1090 +/- 178 MW-55 10/08/13 TBE 3210 +/- 378 MW-55 10/08/13 TBE 3020 +/- 358 MW-55 10/08/13 EIML 3470 +/- 184 MW-561 01/08/13 TBE 6070 +/- 648 MW-561 01/08/13 TBE 5840 +/- 622 MW-561 01/08/13 EIML 6376 +/- 232 MW-561 02/12/13 4850 +/- 533 MW-561 03/05/13 4650 +/- 507 MW-561 04/08/13 TBE 5340 +/- 580 < 6.7
  • 0.9 0.6 +/- 0.3 < 1.0 4.1 +/- 0.7 < 1.6 MW-561 04/08/13 TBE 5270 +/- 575 < 8.4
  • 0.9 < 0.4 < 0.5 3.9 +/- 0.7 < 1.5 MW-561 04/08/13 EIML 6330 +/- 235 < 1.0
  • 0.6 MW-561 07/11/13 9150 +/- 959 MW-561 10/08/13 5560 +/- 601 MW-571 01/08/13 6400 +/- 677 MW-571 02/12/13 15200 +/- 1560 MW-571 03/05/13 13100 +/- 1340 MW-571 04/08/13 18700 +/- 1910 < 7.5 < 0.9 < 0.9 1.0 +/- 0.7 23.1 +/- 1.6 2.0 +/- 1.1 MW-571 07/09/13 TBE 11900 +/- 1240 MW-571 07/09/13 TBE 11700 +/- 1220 MW-571 07/09/13 EIML 14068 +/- 349 MW-571 10/08/13 TBE 773 +/- 153 MW-571 10/08/13 TBE 778 +/- 152 MW-571 10/08/13 EIML 1074 +/- 121 MW-581 01/08/13 < 167 MW-581 04/09/13 < 179 < 0.4 < 0.7 1.7 +/- 0.7 < 2.0 MW-581 07/09/13 < 170 MW-581 10/08/13 < 192 MW-581 12/16/13 < 6.7 < 0.7 MW-591 01/08/13 TBE < 195 MW-591 01/08/13 TBE < 173 MW-591 01/08/13 EIML 290 +/- 84 B-2

TABLE B-I.1 CONCENTRATIONS OF TRITIUM, STRONTIUM-89, STRONTIUM-90, GROSS ALPHA AND GROSS BETA IN GROUNDWATER SAMPLES COLLECTED AS PART OF THE RADIOLOGICAL GROUNDWATER PROTECTION PROGRAM, OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA COLLECTION SITE DATE H-3 Sr-89 Sr-90 Gr-A (Dis) Gr-A (Sus) Gr-B (Dis) Gr-B (Sus)

MW-591 04/09/13 TBE < 194 0.8 +/- 0.4 < 0.4 3.2 +/- 0.7 < 1.4 MW-591 04/09/13 TBE < 193 1.2 +/- 0.4 <0.4 4.5 +/- 0.8 < 1.5 MW-591 04/09/13 EIML < 145 MW-591 07/09/13 < 171 MW-591 10/09/13 < 190 MW-591 12117/13 < 5.5 < 0.7 MW-601 01/08/13 < 167 MW-601 04/09/13 < 179 < 0.2 <0.7 1.4 +/- 0.6 < 1.5 MW-601 07/09/13 < 168 MW-601 10/08/13 < 186 MW-601 12/16/13 < 4.6 < 0.6 MW-61 I 01/08/13 < 165 MW-611 04/09/13 < 175 < 2.0 < 0.8 < 0.4 0.9 +/- 0.6 2.2 +/- 0.6 < 1.5 MW-61 I 07/11/13 < 194 MW-611 10/08/13 < 190 MW-62 03/05/13 < 166 MW-62 04/08/13 < 175 < 1.2 < 0.7 12.8 +/- 1.4 < 1.7 MW-62 07/11/13 < 193 MW-62 10/09/13 < 187 MW-62 12/17/13 < 4.3 < 0.5 MW-631 01/08/13 < 168 MW-631 04/09/13 < 176 < 0.4 < 0.7 5.5 +/- 0.9 < 1.5 MW-631 07/11/13 < 193 MW-631 10/08/13 < 187 MW-631 12/16/13 < 6.0 < 0.6 MW-64 01/08/13 328 +/- 122 MW-64 02/12/13 217 +/- 118 MW-64 03/05/13 < 164 MW-64 04/09/13 < 159 < 8.4 < 0.7 1.7 +/- 1.0 28.8 +/- 9.9 8.4 +/- 2.2 89.0 +/- 11.8 MW-64 07/09/13 < 167 MW-64 10/08/13 < 184 MW-65 01/08/13 < 167 MW-65 02/12/13 < 171 MW-65 03/05/13 < 167 MW-65 04/09/13 < 158 1.1 +/- 0.6 < 0.4 5.4 +/- 1.1 < 1.4 MW-65 07/09/13 < 170 MW-65 10/09/13 < 189 MW-65 12/17/13 < 4.6 < 0.5 MW-661 01/09/13 < 196 MW-661 04/10/13 < 178 < 0.2 < 0.7 2.9 +/- 0.6 < 1.5 MW-661 07/10/13 < 170 MW-661 10/09/13 < 189 MW-661 12/17/13 < 5.5 < 0.6 MW-67 01/08/13 73300 +/- 6290 MW-67 02/12/13 14900 +/- 1540 MW-67 03/05/13 8030 +/- 845 MW-67 04/08/13 16600 +/- 1700 < 4.7 < 0.8 0.7 +/- 0.4 3.8 +/- 1.8 4.4 +/- 0.7 10.5 +/- 2.2 MW-67 07/09/13 TBE 18900 +/- 1920 MW-67 07/09/13 TBE 20900 +/- 2130 MW-67 07/09/13 EIML 23003 +/- 441 MW-67 10/09/13 11500 +/- 1210 MW-681 01/09/13 < 167 B-3

TABLE B-I.1 CONCENTRATIONS OF TRITIUM, STRONTIUM-89, STRONTIUM-90, GROSS ALPHA AND GROSS BETA IN GROUNDWATER SAMPLES COLLECTED AS PART OF THE RADIOLOGICAL GROUNDWATER PROTECTION PROGRAM, OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA COLLECTION SITE DATE H-3 Sr-89 Sr-90 Gr-A (Dis) Gr-A (Sus) Gr-B (Dis) Gr-B (Sus)

MW-681 04/10/13 < 179 0.4 +/- 0.2 < 0.7 1.5 +/- 0.6 < 1.5 MW-681 07/10/13 < 171 MW-681 10/09/13 < 191 MW-681 12/17/13 < 5.1 < 0.6 MW-691 01/09/13 < 197 MW-691 04/10/13 < 178 0.4 +/- 0.2 < 0.7 2.9 +/- 0.6 < 1.6 MW-691 07/10/13 < 171 MW-691 10/09/13 < 190 MW-691 12/17/13 <4.5 <0.8 MW-701 01/09/13 < 196 MW-701 04/10/13 < 178 < 0.3 < 0.7 8.5 +/- 0.8 < 1.5 MW-701 07/10/13 TBE < 172 MW-701 07/10/13 TBE < 196 MW-701 07/10/13 EIML < 159 MW-701 10/09/13 < 191 MW-701 12/17/13 <5.8 <0.6 MW-71 01/09/13 < 194 MW-71 04/10/13 < 179

  • 1.2
  • 0.7 6.9 +/- 1.1 < 2.0 MW-71 07/10/13 < 172 MW-71 10/09/13 < 187 MW-71 12/18/13 <7.3 <1.0 MW-72 01/09/13
  • 187 MW-72 04/10113
  • 175
  • 0.4
  • 0.7 10.5 +/- 1.0 < 1.5 MW-72 07/10/13
  • 172 MW-72 10/09/13
  • 190 MW-72 12/18/13 < 5.1 < 0.7 NDW 11/21/13
  • 188 SDW 10/10/13
  • 182 W-10 01/09/13
  • 179 W-10 04/10/13
  • 171
  • 0.5
  • 1.0 1.5 + 0.6 < 1.7 W-10 07/17/13
  • 185 W-10 10/15/13
  • 157 W-10 12/17/13 < 6.7 < 0.7 W-12 01/09/13
  • 182 W-12 04/10/13
  • 178
  • 0.7
  • 2.5 2.1 +/- 0.7 38.9 +/- 3.7 W-12 07/17/13
  • 163 W-12 10111/13
  • 150 W-12 12/17/13 < 5.6 < 0.9 W-13 01/09/13
  • 181 W-13 04/10/13
  • 179 < 0.6 <1.1 1.8 +/- 0.7 2.0 +/- 1.2 W-13 07/17/13
  • 174 W-13 10/11/13
  • 147 W-13 12/17/13 <7.7 <0.8 W-14 01/09/13
  • 185 W-14 04/09/13
  • 179 0.7 +/- 0.3 < 0.4 3.2 +/- 0.6 < 1.5 W-14 07/17/13
  • 174 W-14 10/11/13
  • 154 W-14 12/18/13 <7.1 <0.6 W-15 01/09/13
  • 184 W-15 04/09/13
  • 176 < 0.5 2.1 +/- 0.9 3.9 +/- 0.8 2.6 +/- 1.2 W-15 07/17/13
  • 176 W-15 10/11/13
  • 153 B-4

TABLE B-1.1 CONCENTRATIONS OF TRITIUM, STRONTIUM-89, STRONTIUM-90, GROSS ALPHA AND GROSS BETA IN GROUNDWATER SAMPLES COLLECTED AS PART OF THE RADIOLOGICAL GROUNDWATER PROTECTION PROGRAM, OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA COLLECTION SITE DATE H-3 Sr-89 Sr-90 Gr-A (Dis) Gr-A (Sus) Gr-B (Dis) Gr-B (Sus)

W-15 12/18/13 < 7.0 < 0.7 W-16 01/09/13

  • 182 W-16 04/10/13
  • 178 < 0.4 9.3 +/- 3.7 2.6 +/- 0.7 35.0 +/- 4.5 W-16 07/17/13
  • 175 W-16 10/15/13
  • 157 W-16 12/17/13 < 6.5 < 0.7 W-1A 04/11/13 < 179 W-24 01/09/13 TBEE < 185 W-24 01/09/13 TBEE < 188 W-24 01/09/13 EIN IL < 141 W-24 04/10/13 TBEE < 174 < 0.7 1.7 +/- 0.8 7.2 +/- 1.0 2.2 +/- 1.1 W-24 04/10/13 TBEE < 176 4.3 +/- 1.8 1.6 +/- 0.9 11.3 +/- 1.4 < 2.0 W-24 04/10/13 EIIMIL < 145 W-24 07/18/13 < 175 W-24 07/18/13 < 178 W-24 10/15/13 TB! E < 157 W-24 10/15/13 TB! E <153 W-24 10/15/13 EIV 1L < 147 W-24 12/16/13 < 7.4 < 0.9 W-2B 04/11/13 < 180 W-3 01/08/13 TB! E < 167 W-3 01/08/13 TB! E < 193 W-3 01/08/13 EINIL < 141 W-3 02/12/13 < 172 W-3 03/05/13 < 169 W-3 04/09/13 TB1E < 176 < 0.4 1.0 +/- 0.7 1.2 +/- 0.6 2.4 +/- 1.1 W-3 04/09/13 TB1E < 176 1.3 +/- 0.6 < 0.5 5.4 +/- 0.9 1.8 +/- 1.1 W-3 04/09/13 EIl IL < 145 W-3 07/09/13 TB1E < 172 W-3 07/09/13 TB! E < 171 W-3 07/09/13 EII IL < 159 W-3 10/08/13 TB! E < 188 W-3 10/08/13 TB! E < 186 W-3 10/08/13 EI!NIL < 155 W-3 12/16/13 < 7.9 < 0.7 W-34 01/09/13
  • 180 W-34 04/10/13
  • 179 < 1.0 1.2 +/- 0.6 17.8 +/- 1.5 < 1.5 W-34 07/18/13
  • 162 W-34 10/15/13
  • 189 W-34 12/16/13 < 8.6 < 0.8 W-4 01/08/13
  • 164 W-4 04/09/13
  • 158 < 0.6 < 0.3 2.4 +/- 0.8 < 1.7 W-4 07/09/13
  • 170 W-4 10/08/13
  • 186 W-4 12/16/13 < 9.0 < 0.8 W-4A 04/11/13
  • 181 W-4B 04/11/13
  • 179 W-5 01/08/13
  • 167 W-5 04/09/13
  • 192 < 0.4 1.2 +/- 0.7 4.5 +/- 0.8 < 1.6 W-5 07/09/13
  • 169 W-5 10/09/13
  • 191 W-5 12/17/13 < 6.9 < 0.6 B-5

TABLE B-I.1 CONCENTRATIONS OF TRITIUM, STRONTIUM-89, STRONTIUM-90, GROSS ALPHA AND GROSS BETA IN GROUNDWATER SAMPLES COLLECTED AS PART OF THE RADIOLOGICAL GROUNDWATER PROTECTION PROGRAM, OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA COLLECTION SITE DATE H-3 Sr-89 Sr-90 Gr-A (Dis) Gr-A (Sus) Gr-B (Dis) Gr-B (Sus)

W-5C 04/11/13 < 182 W-5K 04/11/13 TBE < 178 W-5K 04/11/13 TBE < 178 W-5K 04/11/13 EIML < 145 W-6 01/08/13 < 166 W-6 04/09/13 < 194 2.3 +/- 0.7 < 0.7 7.9 +/- 1.0 < 1.9 W-6 07/09/13 < 167 W-6 10/09/13 < 189 W-6 12/17/13 < 5.9 < 0.6 W-7 01/09/13

  • 175 W-7 04/10/13
  • 180 < 4.5 1.6 +/- 0.9 22.4 +/- 2.1 < 1.7 W-7 07/18/13
  • 176 W-7 10/15/13
  • 156 W-7 12/16/13 < 5.8 < 0.6 W-9 01/09/13
  • 179 W-9 04/10/13
  • 177
  • 1.4 < 1.0 10.1 +/- 1.4 < 1.7 W-9 07/17/13
  • 185 W-9 10/15/13
  • 156 W-9 12/17/13 < 6.3 < 0.7 B-6

TABLE B-I.2 CONCENTRATIONS OF GAMMA EMITTERS IN GROUNDWATER SAMPLES COLLECTED IN THE VICINITY OF OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA SITE COLLECTION Be-7 K-40 Mn-54 Co-58 Fe-59 Co-60 Zn-65 Nb-95 Zr-95 1-131 Cs-134 Cs-137 Ba-140 La-140 DATE LW-3 04/10/13 < 49 < 38 <5 <5 <12 <5 < 11 <6 < 10 < 14 <5 <5 < 34 < 12 LW-4 04/10/13 < 39 < 39 <4 <4 <11 <4 <9 <5 <8 < 13 <4 <4 < 29 < 10 MW-15K-lA 04109/13 < 70 < 53 <7 <5 <11 <6 < 13 <7 < 14 < 14 <7 <7 <36 <9 MW-16D 04/10/13 < 36 < 85 <4 <4 <10 <5 <8 <5 <8 < 13 <4 <5 < 26 <8 MW-1A-2A 04/10/13 < 36 < 61 <4 <4 <8 <4 <5 <4 <8 < 10 <3 <4 < 24 <8 MW-11-1A 04/09/13 < 44 127 +/- 41 <4 <4 <10 <5 <8 <5 <9 < 15 <5 <5 < 30 < 12 MW-1 I-2A 04/09/13 < 36 < 34 <3 <4 <8 <4 <7 <4 <7 < 13 <3 <4 < 25 <8 MW-50 04/08/13 TBE < 24 < 31 <3 <3 <6 <3 <7 <3 <5 <5 <3 <3 < 15 <5 MW-50 04/08/13 TBE < 24 < 23 <3 <3 <5 <3 <5 <3 <5 <5 <3 <3 < 14 <4 MW-50 04/08/13 EIML < 23 < 52 <2 <2 <6 <2 <5 <2 <4 <8 <2 <2 < 17 <3 MW-52 04/09/13 < 64 < 54 <7 <6 <13 <6 < 14 <7 < 12 < 14 <8 <7 .< 34 < 10 MW-53 04/09/13 < 41 < 89 <5 <5 <11 <5 <9 <5 <8 < 10 <4 <5 < 26 <9 MW-54 04/09/13 < 45 < 65 <5 <6 <10 <6 < 13 <6 < 11 < 11 <5 <5 < 27 < 11 MW-55 04/08/13 < 35 < 72 <4 <4 <8 <4 <8 <4 <7 <8 <4 < 4 <. 20 <6 MW-561 04/08/13 TBE < 41 < 82 <4 <4 <9 <4 <7 <5 <6 <9 <4 <4 < 21 <6 MW-561 04/08/13 TBE < 32 < 37 <4 <3 <7 <4 <8 <4 <6 <7 <3 <4 < 18 <6 MW-561 04/08/13 EIML < 30 < 57 <2 <2 <7 <3 <4 <3 <5 < 13 <3 <2 < 20 <3 MW-571 04/08/13 < 29 < 26 <3 <3 <7 <3 <4 <3 <6 <7 <3 <3 < 16 <4 MW-581 04/09/13 < 43 < 39 <4 <5 <9 <5 <8 <5 <8 < 15 <4 <5 < 32 < 10 MW-591 04109/13 TBE < 40 < 88 <5 <5 <9 <5 < 10 <5 <8 <9 <4 < 5 < 24 <7 MW-591 04/09/13 TBE < 35 < 44 <4 <5 <9 <5 <9 <5 <8 <7 <4 <5 < 22 <7 MW-591 04/09/13 EIML < 25 < 42 <2 <2 <7 <2 <3 <2 <5 < 11 <2 <2 < 17 <4 MW-601 04/09/13 < 35 < 64 <3 <3 <8 <3 <6 <4 <6 < 11 <3 <4 < 23 <7 MW-611 04/09/13 < 29 < 26 <3 <3 <8 <3 <7 <3 <6 < 10 <3 <3 < 19 <8 MW-62 04/08/13 < 26 < 84 <3 <3 <6 <3 <6 <3 <6 <5 <3 <3 < 15 <5 MW-631 04/09/13 < 32 < 65 <3 <4 <7 <3 <7 <4 <7 < 10 <3 <4 < 22 <7 MW-64 04/09/13 < 60 < 59 <7 <8 <13 <6 < 12 <8 < 11 < 11 .< 6 <6 <34 < 11 MW-65 04/09/13 < 34 < 78 <4 <4 <8 <4 <8 <4 <6 <7 <3 <4 < 20 <6 MW-661 04/10/13 < 29 < 28 <3 <3 <8 <3 <6 <4 <6 < 11 <3 <3 < 24 <7 MW-67 04/08/13 < 19 < 59 <2 <2 <4 <2 <4 <2 <3 <4 <2 <2 < 11 <3 MW-681 04/10/13 < 38 < 74 <4 <5 <11 <4 < 10 <4 <8 < 14 <4 <4 < 30 < 10 MW-691 04/10/13 < 49 < 39 <4 <5 <8 <4 < 10 <5 <8 < 14 <4 <5 < 33 <9 MW-701 04/10/13 < 35 < 41 <5 <4 <10 <5 <8 <5 <7 < 12 <4 <4 < 31 <9 MW-71 04/10/13 < 48 < 104 <5 <6 <13 <6 < 12 <6 < 11 < 15 <5 <6 <36 < 13 MW-72 04/10/13 < 38 < 33 <4 <4 <9 <3 <8 <4 <7 < 13 <4 <4 < 26 <8 NDW 11/21/13 < 17 < 35 <1 <2 <4 <1 <3 <2 <3 < 23 <1 <2 < 28 <8 SDW 10/10/13 < 23 < 65 <3 <3 <5 <3 <4 <3 <4 < 12 <2 <2 < 24 <8 W-10 04/10/13 < 37 < 81 <3 <4 <9 <4 <8 <4 <8 < 11 <4 <5 < 22 <8 BOLDED VALUES INDICATE LLD WAS NOT MET DUE TO THE AGE OF THE SAMPLE AT TIME OF RECEIPT AT THE LABORATORY

TABLE B-1.2 CONCENTRATIONS OF GAMMA EMITTERS IN GROUNDWATER SAMPLES COLLECTED IN THE VICINITY OF OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA SITE COLLECTION Be-7 K-40 Mn-54 Co-58 Fe-59 Co-60 Zn-65 Nb-95 Zr-95 1-131 Cs-134 Cs-137 Ba-140 La-140 DATE W-12 04/10/13 < 48 < 58 < 5 < 6 <12 <5 <12 <5 <9 < 13 <5 <5 < 32 < 10 W-13 04/10/13 < 41 < 37 < 4 < 5 <10 <5 <7 <5 <7 < 11 <5 <5 < 27 < 10 W-14 04/09/13 < 37 < 31 < 4 < 4 <9 <4 <7 <5 <7 < 12 <4 <4 <27 <7 W-1 5 04/09/13 < 42 < 35 < 4 < 5 <10 <5 <7 <5 <8 < 14 <4 <4 < 30 <8 W-16 04/10/13 < 36 < 71 < 4 < 4 <8 <4 <7 <4 <6 < 11 <3 <4 <27 <8 W-1A 04/11/13 < 33 < 71 < 4 < 4 <9 <4 <8 <4 <7 < 10 <4 <<4 <24 < 7 W-24 04/10/13 TBE < 34 < 33 < 3 < 4 <7 <4 <7 <4 <6 < 10 <3 <4 <21 <7 W-24 04/10/13 TBE < 45 < 84 <4 < 4 <9 <4 <9 <5 <9 < 14 <4 <4 < 28 < 10 W-24 04/10/13 EIML < 27 < 44 < 2 < 2 <6 <3 <5 <2 <3 < 13 <2 <3 <26 <4 W-2B 04/11/13 < 48 < 31 < 5 < 5 <12 <5 <12 <6 <9 < 12 <5 <6 <29 < 11 W-3 04/09/13 TBE <40 < 29 < 4 < 4 <8 <4 <8 <4 <7 <8 <4 <4 <20 < 5 W-3 04/09/13 TBE < 38 73 46 < 4 < 4 <8 <4 <9 <4 <7 <8 <4 <4 <21 <5 W-3 04/09/13 EIML < 34 < 59 < 3 < 3 <9 <3 <5 <4 <5 < 10 <4 <3 <20 <4 80 W-34 04/10/13 < 36 < 85 < 4 < 4 <9 <4 <7 <4 <7 < 10 <3 <4 <25 <6 W-4 04/09/13 < 38 < 32 < 4 < 4 <10 <5 <10 <5 <8 <8 <4 <4 <21 <7 W-4A 04/11/13 < 48 < 76 < 6 < 7 <13 <8 <11 <7 <12 < 13 <6 <6 <36 <12 W-4B 04/11/13 < 38 < 30 < 4 < 3 <7 <3 <9 <4 <7 < 10 <4 <5 < 24 <9 W-5 04/09/13 < 52 < 103 < 6 < 5 <12 <6 < 13 <6 < 11 < 10 <5 <6 <30 <7 W-5C 04/11/13 < 49 < 50 < 5 < 5 <11 <5 < 12 < 5 < 10 < 15 <5 <5 < 30 < 7 W-5K 04/11/13 TBE < 41 < 86 < 5 < 4 <11 <4 <10 <5 <7 < 11 <4 <5 < 32 <9 W-5K 04/11/13 TBE < 39 < 80 < 4 < 4 <9 <5 <8 <4 <6 < 12 <5 <4 <26 <8 W-5K 04/11/13 EIML < 23 67+/-35 <3 < 2 <6 <1 <3 <3 <6 < 12 <2 <2 <27 <5 W-6 04/09/13 < 46 < 45 < 5 < 5 <11 <5 <10 <5 <8 <9 <5 <6 <26 < 7 W-7 04/10/13 < 47 < 43 < 5 < 5 <9 <5 <10 <5 <9 < 12 <4 <4 < 30 < 7 W-9 04/10/13 < 47 < 124 < 5 < 4 <12 <6 <9 <6 <9 < 14 <5 <5 < 35 < 10 BOLDED VALUES INDICATE LLD WAS NOT MET DUE TO THE AGE OF THE SAMPLE AT TIME OF RECEIPT AT THE LABORATORY

TABLE B-1.3 CONCENTRATIONS OF HARD TO DETECTS IN GROUNDWATER SAMPLES COLLECTED AS PART OF THE RADIOLOGICAL GROUNDWATER PROTECTION PROGRAM, OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA SITE COLLECTION Am-241 Cm-242 Cm-243/244 Pu-238 Pu-239/240 U-234 U-235 U-238 Fe-55 Ni-63 DATE MW-15K-1A 04/09113 < 0.14 < 0.06 < 0.07 < 0.02 < 0.03 < 0.09 < 0.04 < 0.07 < 133 < 3.8 MW-50 04/08/13 TBE < 0.07 < 0.04 < 0.03 < 0.05 .< 0.03 < 0.18 < 0.05 < 0.13 < 88 < 3.9 MW-50 04/08/13 TBE < 0.02 < 0.05 < 0.06 < 0.04 < 0.03 < 0.10 < 0.04 < 0.12 < 58 < 4.0 MW-50 04108/13 EIML < 0.20 - < 0.19 < 0.08 < 0.13 < 0.13 - < 0.12 < 770 < 115 MW-54 04/09/13 < 0.13 < 0.09 < 0.05 < 0.16 < 0.06 < 0.18 < 0.16 < 0.09 < 68 < 4.8 MW-55 04/08/13 < 0.06 < 0.03 < 0.02 < 0.07 < 0.07 < 0.04 < 0.03 < 0.02 < 97 < 3.8 MW-561 04/08/13 TBE < 0.05 < 0.02 < 0.02 < 0.13 < 0.05 < 0.12 < 0.06 < 0.08 < 149 < 3.8 MW-561 04/08/13 TBE < 0.03 < 0.02 < 0.01 < 0.03 < 0.08 < 0.14 < 0.10 < 0.08 < 94 < 3.9 MW-561 04/08/13 EIML < 0.22 - < 0.22 < 0.32 < 0.18 0.35 + 0.14 - 0.19 + 0.11 < 775 < 119 MW-571 04/08/13 < 0.03 < 0.02 < 0.05 < 0.02 < 0.02 < 0.12 < 0.11 < 0.15 < 102 < 3.8 MW-611 04/09/13 < 0.14 < 0.07 < 0.06 < 0.08 < 0.06 < 0.01 < 0.01 < 0.01 < 102 < 3.9 MW-64 04/09/13 < 0.10 < 0.07 < 0.19 < 0.02 < 0.02 < 0.14 < 0.12 < 0.14 < 126 < 4.7

,.0 MW-67 04/08/13 < 0.05 < 0.06 < 0.03 < 0.08 < 0.03 < 0.13 < 0.12 < 0.05 < 48 < 4.2

TABLE B-II.1 CONCENTRATIONS OF TRITIUM, STRONTIUM-89, AND STRONTIUM-90 IN SURFACE WATER SAMPLES COLLECTED AS PART OF THE RADIOLOGICAL GROUNDWATER PROTECTION PROGRAM, OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA COLLECTION SITE DATE H-3 SR-89 SR-90 MCD 01/01/13 < 169 MCD 01/02/13 < 170 MCD 01/03/13 < 167 MCD 01/04/13

  • 166 MCD 01/05/13 < 166 MCD 01/06/13 < 169 MCD 01/07/13 < 166 MCD 01/08/13
  • 168 MCD 01/09/13 < 167 MCD 01/10/13 < 177 MCD 01/11/13 < 182 MCD 01/12/13 < 176 MCD 01/13/13 < 176 MCD 01/14/13 < 177 MCD 01/15/13 < 181 MCD 01/16/13
  • 174 MCD 01/17/13
  • 179 MCD 01/18/13 < 180 MCD 01/19/13 < 179 MCD 01/20113
  • 178 MCD 01/21/13 < 180 MCD 01/22/13 < 180 MCD 01/23/13 < 186 MCD 01/24/13 < 179 MCD 01/25/13 < 181 MCD 01/26/13 < 178 MCD 01/27/13 < 183 MCD 01/28/13 < 190 MCD 01/29/13 < 186 MCD 01/30/13 < 191 MCD 01/31/13 < 193 MCD 02/01/13 < 190 MCD 02/02/13 < 188 MCD 02/03/13 < 190 MCD 02/04/13 < 188 MCD 02/05/13 < 192 MCD 02/06/13 < 188 MCD 02/07/13 < 188 MCD 02/08/13 < 189 MCD 02/09/13 < 181 MCD 02/10/13 < 174 MCD 02/11/13 < 177 MCD 02/12/13
  • 175 MCD 02/13/13 < 192 MCD 02/14/13 < 189 MCD 02/15/13 < 187 MCD 02/16/13 < 189 MCD 02/17/13 < 163 MCD 02/18/13 < 163 MCD 02/19/13 < 163 MCD 02/20/13 < 160 MCD 02/21/13 < 165 B-10

TABLE B-11.1 CONCENTRATIONS OF TRITIUM, STRONTIUM-89, AND STRONTIUM-90 IN SURFACE WATER SAMPLES COLLECTED AS PART OF THE RADIOLOGICAL GROUNDWATER PROTECTION PROGRAM, OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/-12 SIGMA COLLECTION SITE DATE H-3 SR-89 SR-90 MCD 02/22113 < 166 MCD 02/23/13 < 162 MCD 02/24/13 < 164 MCD 02/25/13 < 165 MCD 02/26/13 < 163 MCD 02/27/13 < 167 MCD 02/28/13 < 159 MCD 03/01/13 < 165 MCD 03/02/13 < 165 MCD 03/03/13 < 160 MCD 03/04/13 < 166 MCD 03/05/13 < 169 MCD 03/06/13 < 165 MCD 03/07/13 < 183 MCD 03/08/13 < 179 MCD 03/09/13 < 182 MCD 03/10/13 < 182 MCD 03/11/13 < 182 MCD 03/12/13 < 181 MCD 03/13/13 < 179 MCD 03/14/13 < 181 MCD 03/15/13 < 180 MCD 03/16/13 < 180 MCD 03/17/13 < 179 MCD 03/18/13 < 178 MCD 03/19/13 < 184 MCD 03/20/13 < 180 MCD 03/21/13 < 182 MCD 03/22/13 < 183 MCD 03/23/13 < 182 MCD 03/24/13 < 184 MCD 03/25/13 < 183 MCD 03/26/13 < 182 MCD 03/27/13 < 183 MCD 03/28/13 < 181 MCD 03/29/13 < 182 MCD 03/30/13 < 183 MCD 03/31/13 < 184 MCD 04/01/13 < 183 MCD 04/02/13 < 182 MCD 04/03113 < 183 MCD 04/04/13 < 183 MCD 04/05/13 < 186 MCD 04/06/13 < 181 MCD 04/07/13 < 180 MCD 04/08/13 < 182 MCD 04/09/13 < 184 MCD 04/10/13 < 182 MCD 04/11/13 < 174 MCD 04/12/13 < 184 MCD 04/13/13 < 183 MCD 04/14/13 < 182 B-II

TABLE B-II.1 CONCENTRATIONS OF TRITIUM, STRONTIUM-89, AND STRONTIUM-90 IN SURFACE WATER SAMPLES COLLECTED AS PART OF THE RADIOLOGICAL GROUNDWATER PROTECTION PROGRAM, OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA COLLECTION SITE DATE H-3 SR-89 SR-90 MCD 04/15/13 < 180 MCD 04/16/13 < 194 MCD 04/17/13 < 186 MCD 04/18/13 < 174 MCD 04/19/13 < 186 MCD 04/20/13 < 181 MCD 04/21/13 < 176 MCD 04/22/13

  • 185 MCD 04123/13 < 183 MCD 04/24/13 < 184 MCD 04/25/13 < 180 MCD 04/26/13 < 181 MCD 04/27/13 < 187 MCD 04/28/13 < 187 MCD 04/29/13 < 186 MCD 04/30/13 < 188 MCD 05/01/13 < 184 MCD 05/02/13 < 184 MCD 05/03/13 < 184 MCD 05/04/13
  • 195 MCD 05/05/13 < 190 MCD 05/06/13 < 194 MCD 05/07/13 < 183 MCD 05/08/13 < 185 MCD 05/09/13 < 188 MCD 05/10/13 < 184 MCD 05/11/13 < 184 MCD 05/12/13 < 193 MCD 05/13/13
  • 183 MCD 05/14/13 < 188 MCD 05/15/13 < 184 MCD 05/16/13 < 186 MCD 05/17/13 < 186 MCD 05/18/13 < 186 MCD 05/19/13
  • 184 MCD 05/20/13 < 188 MCD 05/21/13 < 187 MCD 05/22/13 < 187 MCD 05/23/13 < 189 MCD 05/24/13 < 180 MCD 05/25/13 < 168 MCD 05/26/13 < 189 MCD 05/27/13 < 165 MCD 05/28/13 < 194 MCD 05/29/13 < 192 MCD 05/30/13 < 188 MCD 05/31/13 < 175 MCD 06/01/13 < 172 MCD 06/02/13 < 175 MCD 06/03/13 < 177 MCD 06/04/13 < 175 MCD 06/05/13 < 176 B-12

TABLE B-II.1 CONCENTRATIONS OF TRITIUM, STRONTIUM-89, AND STRONTIUM-90 IN SURFACE WATER SAMPLES COLLECTED AS PART OF THE RADIOLOGICAL GROUNDWATER PROTECTION PROGRAM, OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA COLLECTION SITE DATE H-3 SR-89 SR-90 MCD 06/06/13 < 174 MCD 06/07/13 < 176 MCD 06/08/13 < 177 MCD 06/09/13

  • 171 MCD 06/10/13 < 173 MCD 06/11/13 < 175 MCD 06/12/13 < 172 MCD 06/13/13 < 174 MCD 06/14/13 < 172 MCD 06/15/13 < 175 MCD 06/16/13 < 176 MCD 06/17/13 < 176 MCD 06/18/13 < 177 MCD 06/19/13 < 175 MCD 06/20/13 < 178 MCD 06/21/13 < 175 MCD 06/22/13 < 172 MCD 06/23/13 < 174 MCD 06/24/13
  • 167 MCD 06/25/13 < 177 MCD 06/26/13 < 176 MCD 06/27/13 < 176 MCD 06/28/13 < 175 MCD 06/29/13 < 174 MCD 06/30/13
  • 176 MCD 07/01/13 < 176 MCD 07/02/13 < 175 MCD 07/03/13 < 175 MCD 07/04/13 < 173 MCD 07/05/13
  • 175 MCD 07/06/13 < 192 MCD 07/07/13 < 193 MCD 07/08/13 < 194 MCD 07/09/13 < 195 MCD 07/10/13 < 194 MCD 07/11/13 < 194 MCD 07/12/13 < 190 MCD 07/13/13 < 188 MCD 07/14/13 < 188 MCD 07/15/13 < 192 MCD 07/16/13 < 192 MCD 07/17/13 < 194 MCD 07/18/13 < 195 MCD 07/19/13 < 194 MCD 07/20/13 < 196 MCD 07/21/13 < 195 MCD 07122/13 < 196 MCD 07/23/13 < 192 MCD 07/24/13 < 194 MCD 07/25/13 < 196 MCD 07/26/13 < 199 MCD 07/27/13 < 193 B-13

TABLE B-II.1 CONCENTRATIONS OF TRITIUM, STRONTIUM-89, AND STRONTIUM-90 IN SURFACE WATER SAMPLES COLLECTED AS PART OF THE RADIOLOGICAL GROUNDWATER PROTECTION PROGRAM, OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA COLLECTION SITE DATE H-3 SR-89 SR-90 MCD 07/28/13 < 193 MCD 07/29/13 < 194 MCD 07/30/13 < 188 MCD 07/31/13 < 186 MCD 08/01/13 < 191 MCD 08/02/13 < 190 MCD 08/03/13 < 194 MCD 08/04/13 < 195 MCD 08/05/13 < 196 MCD 08/06/13 < 194 MCD 08/07/13 < 194 MCD 08/08/13 < 195 MCD 08/09/13 < 195 MCD 08/10/13 < 190 MCD 08/11/13 < 196 MCD 08/12/13 < 194 MCD 08/13/13 < 194 MCD 08/14/13 < 193 MCD 08/15/13 < 192 MCD 08/16/13 < 191 MCD 08/17/13

  • 189 MCD 08/18/13 < 186 MCD 08/19/13 < 187 MCD 08/20/13 < 187 MCD 08/21/13 < 190 MCD 08/22/13 < 190 MCD 08/23/13 < 189 MCD 08/24/13 < 189 MCD 08/25/13 < 188 MCD 08/26/13 < 188 MCD 08/27/13 < 187 MCD 08/28/13 < 189 MCD 08/29/13 < 187 MCD 08/30/13 < 189 MCD 08/31/13
  • 190 MCD 09/01/13 < 166 MCD 09/02/13 < 172 MCD 09/03/13 < 161 MCD 09/04/13 < 166 MCD 09/05/13 < 163 MCD 09106/13 < 165 MCD 09/07/13 < 191 MCD 09/08/13 < 194 MCD 09/09/13 < 192 MCD 09/10/13 < 190 MCD 09/11/13
  • 190 MCD 09/12/13 < 190 MCD 09/13/13 < 191 MCD 09/14/13 < 191 MCD 09/15/13 < 188 MCD 09/16/13 < 189 MCD 09/17/13 < 189 B-14

TABLE B-II.1 CONCENTRATIONS OF TRITIUM, STRONTIUM-89, AND STRONTIUM-90 IN SURFACE WATER SAMPLES COLLECTED AS PART OF THE RADIOLOGICAL GROUNDWATER PROTECTION PROGRAM, OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA COLLECTION SITE DATE H-3 SR-89 SR-90 MCD 09/18/13 < 190 MCD 09/19/13 < 186 MCD 09/20/13 < 189 MCD 09/21/13 < 189 MCI) 09/22/13 < 184 MCD 09/23/13 < 188 MCD 09/24/13 < 187 MCD 09/25/13 < 164 MCD 09/26/13 < 165 MCD 09/27/13 < 164 MCD 09/28/13 < 165 MCD 09/29/13 < 165 MCD 09/30/13 < 162 MCD 10/01/13 < 166 MCD 10/02/13 < 167 MCD 10/03/13 < 192 MCD 10/04/13 < 188 MCD 10/05/13 < 193 MCD 10106/13 < 190 MCD 10/07/13 < 192 MCD 10/08/13 < 188 MCD 10/09/13 < 193 MCD 10/10/13 < 188 MCD 10/11/13 < 191 MCD 10/12/13 < 191 MCD 10/13/13 < 187 MCD 10/14/13 < 190 MCD 10/15/13 < 190 MCD 10/16/13 < 189 MCD 10/17/13 < 186 MCD 10/18/13 < 186 MCD 10/19/13 < 188 MCD 10/20/13 < 185 MCD 10/21/13 < 188 MCD 10/22/13 < 187 MCD 10/23/13 < 185 MCD 10/24/13 < 189 MCD 10/25/13 < 189 MCD 10/26/13 < 188 MCD 10/27/13 < 189 MCD 10/28/13 < 187 MCD 10/29/13 < 194 MCD 10/30/13 < 190 MCD 10/31/13 < 188 MCD 11101/13 < 191 MCD 11/02/13 < 189 MCD 11/03/13 < 189 MCD 11/04/13 < 182 MCD 11/05/13 < 187 MCD 11/06/13 < 188 MCD 11/07/13 < 190 MCD 11/08/13 < 186 B-15

TABLE B-II.1 CONCENTRATIONS OF TRITIUM, STRONTIUM-89, AND STRONTIUM-90 IN SURFACE WATER SAMPLES COLLECTED AS PART OF THE RADIOLOGICAL GROUNDWATER PROTECTION PROGRAM, OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA COLLECTION SITE DATE H-3 SR-89 SR-90 MCD 11/09/13

  • 187 MCD 11/10/13
  • 185 MCD 11/11/13
  • 188 MCD 11/12/13
  • 184 MCD 11/13/13
  • 186 MCD 11/14/13
  • 188 MCD 11/15/13
  • 184 MCD 11/16/13
  • 186 MCD 11/17/13
  • 188 MCD 11/18/13
  • 188 MCD 11/19/13
  • 188 MCD 11/20/13
  • 187 MCD 11/21/13
  • 174 MCD 11/22/13
  • 173 MCD 11/23/13
  • 169 MCD 11/24/13
  • 169 MCD 11/25/13
  • 177 MCD 11/26/13
  • 172 MCD 11/27/13
  • 171 MCD 11/28/13
  • 172 MCD 11/29/13
  • 170 MCD 11/30/13
  • 174 MCD 12/01/13
  • 170 MCD 12/02/13
  • 170 MCD 12/03/13
  • 174 MCD 12/04/13
  • 168 MCD 12/05/13
  • 178 MCD 12/06/13
  • 169 MCD 12/07/13
  • 173 MCD 12/08/13
  • 173 MCD 12/09/13
  • 181 MCD 12/10/13
  • 182 MCD 12/11/13
  • 194 MCD 12/12/13
  • 192 MCD 12/13/13
  • 193 MCD 12/14/13
  • 193 MCD 12/15/13
  • 191 MCD 12/16/13
  • 189 MCD 12/17/13
  • 193 MCD 12/18/13
  • 184 MCD 12/19/13
  • 190 MCD 12/20/13
  • 182 MCD 12/21/13
  • 181 MCD 12/22/13 <184 MCD 12/23/13
  • 177 MCD 12/24/13
  • 182 MCD 12/25/13
  • 181 MCD 12/26/13
  • 179 MCD 12/27/13 < 180 Sw-1 01/02/13 < 194 Sw-1 01/09/13 < 197 Sw-1 01/16/13 < 174 B-16

TABLE B-11.1 CONCENTRATIONS OF TRITIUM, STRONTIUM-89, AND STRONTIUM-90 IN SURFACE WATER SAMPLES COLLECTED AS PART OF THE RADIOLOGICAL GROUNDWATER PROTECTION PROGRAM, OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA COLLECTION SITE DATE H-3 SR-89 SR-90 Sw-1 01/23/13 < 177 Sw-1 01/30/13 < 175 Sw-1 02/06/13 < 176 Sw-1 02/13/13

  • 167 Sw-1 02/20/13 < 160 sw-1 02/27/13 < 166 Sw-1 03/06/13 < 165 Sw-1 03/13/13 < 180 Sw-1 03/20/13 < 177 Sw-1 03/27/13 < 175 Sw-1 04/03/13 < 177 Sw-1 04/10/13 < 190 Sw-1 04/17/13 < 167 Sw-1 04/24/13 < 168 Sw-1 05/01/13
  • 174 Sw-1 05/08/13 < 166 Sw-1 05/15/13 < 166 Sw-1 05/22/13 < 164 Sw-1 05/29/13 < 164 Sw-1 06105/13
  • 193 Sw-1 06/12/13 < 188 Sw-1 06/19/13 < 196 Sw-1 06/26/13 < 191 Sw-1 07/03/13 < 192 Sw-1 07/10/13 < 192 Sw-1 07/17/13 < 185 Sw-1 07/24/13 < 187 Sw-1 07/31/13 < 188 sw-1 08/07/13 < 186 Sw-1 08/14/13 < 190 Sw-1 08/21/13 < 183 Sw-1 08/28/13 < 185 Sw-1 09/04/13 < 182 Sw-1 09/11/13
  • 180 Sw-1 09/18/13
  • 180 Sw-1 09/25/13 < 173 Sw-1 10/02/13 < 182 Sw-1 10/09/13
  • 182 Sw-1 10/16/13
  • 189 Sw-1 10/23/13
  • 188 Sw-1 10/30/13
  • 188 Sw-1 11/06/13 < 188 sw-1 11113/13 < 188 Sw-I 11/20/13 < 184 Sw-1 11/27/13 < 190 Sw-i 12/04/13
  • 193 Sw-1 12/11/13
  • 190 Sw-1 12/19/13 < 178 Sw-1 12/27/13
  • 181 SW-2 01/09/13
  • 187 SW-2 04/11/13
  • 179 SW-2 07/09/13
  • 173 B-17

TABLE B-II.1 CONCENTRATIONS OF TRITIUM, STRONTIUM-89, AND STRONTIUM-90 IN SURFACE WATER SAMPLES COLLECTED AS PART OF THE RADIOLOGICAL GROUNDWATER PROTECTION PROGRAM, OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA COLLECTION SITE DATE H-3 SR-89 SR-90 I

SW-2 10/07/13 < 152 SW-2 12118/13 < 6.6 < 0.8 SW-3 01/09/13 189 SW-3 04/11/13 179 SW-3 07/10/13 192 SW-3 10/07113 152 B-18

TABLE B-II.2 CONCENTRATIONS OF GAMMA EMITTERS IN SURFACE WATER SAMPLES COLLECTED IN THE VICINITY OF OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA SITE COLLECTION Be-7 K-40 Mn-54 Co-58 Fe-59 Co-60 Zn-65 Nb-95 Zr-95 1-131 Cs-134 Cs-137 Ba-140 La-140 DATE MCD 01/01/13 < 50 224 +/- 83 < 5 <6 < 14 <5 <11 <6 <11 < 30 <* <b <54 < 19 MCD 01/02/13 < 48 332 +/- 82 < 5 <5 < 11 <5 <10 <6 <10 < 29 <4 <5 <52 < 14 MCD 01/03/13 < 45 266 +/- 76 < 4 < 5 < 11 <5 <9 <5 <9 < 24 <4 <5 <43 < 12 MCD 01/04/13 < 26 293 +/- 59 < 3 < 3 < 6 <2 <5 <3 <5 < 12 <2 <2 <25 <6 MCD 01/05/13 < 19 243 +/- 50 < 2 < 2 < 6 <2 <4 <2 <4 <9 <2 <2 <19 <6 MCD 01/06/13 < 22 201 +/- 34 < 2 < 3 < 5 <2 <5 <3 <4 < 11 <2 <2 <20 <7 MCD 01/07/13 < 25 306 +/- 64 < 2 < 3 < 6 <3 <5 <3 <5 < 11 <2 <3 <21 <6 MCD 01/08/13 < 31 223 +/- 49 < 3 < 3 < 8 <3 <7 <3 <6 < 12 <3 <3 <25 <8 MCD 01/09/13 < 27 242 +/- 52 < 3 < 3 < 6 <3 <5 <3 <5 < 13 <2 <3 <25 <8 MCD 01/10/13 < 18 266 +/- 54 < 2 < 2 < 5 <2 <3 <2- <4 < 50 <1 <2 <47 < 15 MCD 01/11/13 < 21 201 +/- 65 < 2 < 2 < 5 <1 <4 <2 <4 < 55 <1 <2 <50 < 17 MCD 01/12/13 < 20 228 +/- 45 < 1 < 2 < 5 <1 <3 <2 <4 <46 <1 <1 <47 < 13 MCD 01/13/13 < 29 173 +/- 75 < 2 < 3 < 7 <2 <5 <3 <5 <64 <2 <2 <67 < 19 MCD 01/14/13 < 23 316 +/- 64 < 2 < 2 < 5 <2 <4 <3 <4 < 49 <2 <2 <50 < 14 MCD 01/15/13 < 18 220 +/- 52 < 1 < 2 < 4 <1 <3 <2 <3 < 35 <1 <2 <37 < 12 MCD 01/16/13 < 29 183 +/- 57 < 2 < 3 < 7 <2 <4 <3 <5 < 51 <2 <2 <54 < 15 MCD 01/17/13 < 25 259 +/- 55 < 2 < 2 < 6 <2 <4 <3 <4 < 42 <2 <2 <48 < 14 MCD 01/18/13 < 26 290 +/- 79 < 2 < 2 < 7 <2 <4 <3 <5 < 52 <2 <2 <57 < 16 MCD 01/19/13 < 27 275 +/- 77 < 2 < 3 < 6 <2 <4 <3 <4 <53 <2 <2 <57 < 15 MCD 01/20/13 < 24 299 +/- 64 < 2 < 2 < 7 <3 <4 <2 <4 < 38 <2 <2 <47 < 15 MCD 01/21/13 < 26 223 +/- 57 < 2 < 3 < 6 <2 <4 <3 <5 < 39 <2 <2 <49 < 13 MCD 01/22/13 < 33 255 +/- 69 < 3 < 4 < 8 <3 <7 <4 <6 < 47 <3 <3 <58 < 21 MCD 01/23/13 < 26 262 +/- 66 < 2 < 3 < 7 <3 <4 <3 <5 < 39 <2 <2 <50 < 13 MCD 01/24/13 < 32 306 +/- 75 < 2 < 3 < 7 <3 <5 <3 <5 < 41 <3 <3 <50 < 13 MCD 01/25/13 < 16 294 +/- 46 < 2 < 2 < 4 <1 <3 <2 <3 < 13 <1 <2 <19 <6 MCD 01/26/13 < 28 342 +/- 68 < 3 < 3 < 7 <3 <6 <3 <5 < 21 <2 <3 <34 < 10 MCD 01/27/13 < 19 258 +/- 65 < 2 < 2 < 5 <2 <4 <2 <3 < 14 <2 <2 <23 <6 MCD 01/28/13 < 23 288 +/- 59 < 2 < 2 < 6 <3 <4 <3 <5 < 15 <2 <2 <25 <6 MCD 01/29/13 < 23 322 +/- 82 < 2 < 2 < 6 <2 <4 <3 <5 < 14 <2 <2 <23 <7 MCD 01/30/13 < 20 283 +/- 51 < 2 < 2 < 4 <2 <4 <2 <4 < 11 <2 <2 <21 <6 MCD 01/31/13 < 28 244 +/- 83 < 3 < 3 < 8 <3 <6 <3 <6 < 14 <3 <3 <30 <9 MCD 02/01/13 < 25 346 +/- 70 < 2 < 3 < 6 <2 <5 <3 <5 < 13 <2 <3 <24 <6 MCD 02/02/13 < 22 305 +/- 61 < 2 < 2 < 5 <2 <5 <3 <4 < 10 <2 <3 <20 <6 MCD 02/03/13 < 27 296 +/- 64 < 3 <3 < 6 <3 <5 <3 <5 < 11 <3 <3 <23 <7 MCD 02/04/13 < 22 268 +/- 61 < 2 < 2 < 5 <2 <5 <3 <4 <8 <2 <2 <16 <5 MCD 02/05/13 < 30 315 +/- 46 < 3 < 3 < 7 <3 <6 <4 <6 < 12 <3 <3 <25 <8 MCD 02/06/13 < 35 303 +/- 66 < 4 <4 < 9 <4 <8 <4 <7 < 13 <4 <4 <30 <8 MCD 02/07/13 < 42 287 +/- 66 < 4 < 4 < 9 <4 <9 <5 <8 < 14 <4 <4 <31 <9 BOLDED VALUES INDICATE LLD WAS NOT MET DUE TO THE AGE OF THE SAMPLE AT TIME OF RECEIPT AT THE LABORATORY

TABLE B-II.2 CONCENTRATIONS OF GAMMA EMITTERS IN SURFACE WATER SAMPLES COLLECTED IN THE VICINITY OF OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA SITE COLLECTION Be-7 K-40 Mn-54 Co-58 Fe-59 Co-60 Zn-65 Nb-95 Zr-95 1-131 Cs-134 Cs-137 Ba-140 La-140 DATE MCD 02/08/13 < 38 402 +/- 74 < 4 <4 <9 <5 <<9 <5 <8

  • 13 <4 <4 <28 <9 MCD 02/09/13 < 47 371 +/- 94 < 5 < 5 <11 <5 <10 <6 <10
  • 14 <5 <5 <33 < 10 MCD 02110/13 < 46 374 +/- 79 < 4 < 5 <9 <5 <9 <5 <9
  • 12 <5 <5 <30 <8 MCD 02/11/13 < 38 263 +/- 70 < 4 < 4 <9 <4 <9 <5 <8 < 10 <4 <5 <28 <8 MCD 02/12/13 < 27 272 +/- 83 < 3 < 3 <6 <3 <5 <3 <4 <6 <3 <3 <16 <4 MCD 02/13/13 < 16 253 +/- 45 < 2 < 2 <4 <1 <3 <2 <3
  • 14 <2 <2 <21 <7 MCD 02/14/13 < 19 250 +/- 65 < 2 < 2 <4 <2 <4 <3 <4 < 13 <2 <2 <24 <9 MCD 02/15/13 < 22 198 +/- 64 < 2 < 2 <5 <2 <4 <3 <4 < 15 <2 <2 <22 <6 MCD 02/16/13 < 22 266 +/- 58 < 2 < 2 <5 <3 <4 <3 <4
  • 15 <2 <2 <23 <8 MCD 02/17/13 < 25 249 +/- 72 < 2 < 2 <5 <2 <4 <3 <4 < 14 <2 <3 <22 <8 MCD 02/18/13 < 16 284 +/- 60 < 2 < 2 <4 <2 <3 <2 <3 < 10 <2 <2 <19 <6 MCD 02/19/13 < 30 260 +/- 97 < 3 < 4 <8 <3 <7 <4 <6
  • 14 <3 <3 <32 < 10 w MCD 02/20/13 < 26 321 +/- 67 < 3 < 2 <5 <3 <5 <2 <5
  • 13 <2 <3 <22 <6 MCD 02/21/13 < 25 264 +/- 63 < 3 < 3 <6 <3 <5 <3 <5
  • 12 <2 <3 <24 <6 MCD 02/22/13 < 24 278 +/- 62 < 3 < 2 <6 <2 <4 <2 < 5 <11 <2 <3 <21 <5 MCD 02/23/13 < 21 230 +/- 53 < 2 < 2 <5 <2 <5 <2 <4 <8 <2 <2 <18 <6 MCD 02/24/13 < 28 253 +/- 72 < 2 < 3 <5 <2 <5 <3 <5 <11 <3 <3 <21 <6 MCD 02/25/13 < 25 304 +/- 72 < 3 < 3 <5 <3 <6 <3 <5 <10 <2 <3 <22 <6 MCD 02/26/13 < 25 321 +/- 74 < 3 < 3 <6 <3 <6 <3 <5 <8 <3 <3 <20 <6 MCD 02/27/13 < 28 362 +/- 83 < 3 < 3 <6 <3 <6 <3 <5 <9 <3 <3 <22 <5 MCD 02/28/13 < 24 279 +/- 71 < 2 < 2 <6 <3 <5 <3 <5 <8 <2 <3 <17 <5 MCD 03/01/13 < 20 292 +/- 76 < 2 < 2 <5 <2 <5 <2 <4 <6 <2 <3 <13 <4 MCD 03/02/13 < 33 274 +/- 63 < 4 < 4 <8 <4 <8 <4 <7 <10 <3 <4 <24 <8 MCD 03/03/13 < 25 281 +/- 71 < 3 < 3 <6 <3 <5 <3 <5 <6 <2 <3 <16 <4 MCD 03/04/13 < 23 284 +/- 77 < 3 <2 <5 <3 <5 <3 <5 <5 <2 <3 <15 <5 MCD 03/05/13 < 18 346 +/- 64 <2 < 2 <4 <3 <4 <2 <4 <4 <2 <2 <11 <4 MCD 03/06/13 < 22 358 +/- 70 < 3 <3 <6 <3 <5 <3 <4 <4 <2 <3 <14 <5 MCD 03/07/13 < 22 255 +/- 44 <2 < 2 <6 <2 <3 <3 <4 <54 <1 <2 <48
  • 15 MCD 03/08/13 < 25 341 +/-71 <2 <2 <6 <3 <4 <3 <5 < 53 <2 <2 <54 < 21 MCD 03/09/13 < 27 316 +/- 50 <2 < 3 <6 <2 <4 <3 <5 < 58 <2 <2 <55 < 14 MCD 03/10/13 < 29 273 +/- 92 < 2 <3 <7 <3 <5 <3 <5 < 53 <2 <2 <58 < 14 MCD 03/11/13 < 26 348 +/- 76 <2 <2 <6 <2 <4 <3 <5 < 50 <2 <2 <51
  • 17 MCD 03/12/13 < 28 279 +/- 72 <2 <3 <7 <2 <5 <3 <5 < 52 <2 <2 <53 < 13 MCD 03/13/13 < 28 340 +/- 65 <2 <3 <6 <2 <5 <3 <5 <45 <2 <2 <54 < 12 MCD 03/14/13 < 26 333 +/- 70 <2 <3 <7 <2 <5 <3 <5 <40 <2 <2 <50 < 15 MCD 03/15/13 < 22 306 +/- 63 <2 <2 <6 <3 <4 <3 <5 <34 <2 <2 <41 < 13 MCD 03/16/13 < 29 352 +/- 79 < 2. <3 <7 <3 <5 <3 <6 < 38 <2 <3 <47 < 13 MCD 03/17/13 < 27 345 +/- 77 < 2 <3 <8 <2 <5 <3 <5 < 35 <2 <2 <41 < 13 BOLDED VALUES INDICATE LLD WAS NOT MET DUE TO THE AGE OF THE SAMPLE AT TIME OF RECEIPT AT THE LABORATORY

TABLE B-1I.2 CONCENTRATIONS OF GAMMA EMITTERS IN SURFACE WATER SAMPLES COLLECTED IN THE VICINITY OF OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA SITE COLLECTION Be-7 K-40 Mn-54 Co-58 Fe-59 Co-60 Zn-65 Nb-95 Zr-95 1-131 Cs-134 Cs-137 Ba-140 La- 140 DATE MCD 03/18/13 < 28 284 +/- 75 < 2 < 3 < 6 <2 <5 <3 <5 < 31 <2 <2 <41 < 13 MCD 03/19/13 < 25 224 +/- 62 < 2 < 2 < 7 <2 <5 <3 <5 < 26 <2 <2 <39 < 12 MCD 03/20/13 < 16 221 +/- 39 < 1 < 2 < 4 <1 <3 <2 <3 < 17 <1 <1 <25 <7 MCD 03/21/13 < 25 301 +/- 58 < 2 < 3 < 6 <2 <5 <3 <5 < 27 <2 <2 <38

  • 10 MCD 03/22/13 < 23 234 +/- 64 <2 <2 < 6 <2 <4 <3 <5 < 23 <2 <2 <31 < 10 MCD 03/23/13 < 19 204 +/- 52 < 2 < 2 < 5 <2 <4 <2 <3 < 16 <2 <2 <25 <7 MCD 03/24/13 < 23 223 +/- 66 < 2 < 3 <5 <2 <4 <3 <4 < 20 <2 <2 <28 <8 MCD 03/25/13 < 25 279 +/- 54 < 2 < 2 < 6 <2 <4 <3 <4 < 19 <2 <2 <29 <8 MCD 03/26/13 < 25 236 +/- 74 < 2 < 3 <7 <3 <5 <3 <5 < 17 <2 <2 <28 <7 MCD 03/27/13 < 23 348 +/- 69 < 2 < 2 <6 <2 <4 <3 <5 < 15 <2 <2 <26 <8 MCD 03/28/13 < 28 279 +/- 56 < 3 < 3 < 6 <3 <4 <3 <5 < 18 <2 <3 <27 <7 MCD 03/29/13 < 21 230 +/- 55 <2 < 2 < 5 <2 <4 <2 <4 < 12 <2 <2 <21 <6 MCD 03/30/13 < 16 188 +/- 52 < 2 < 2 < 3 <2 <4 <2 <3 <8 <2 <2 <17 <5 MCD 03/31/13 < 18 253 +/- 46 <2 < 2 < 4 <2 <4 <2 <4 < 11 <2 <2 <20 <5 MCD 04/01/13 < 20 234 +/- 55 <2 <2 <5 <2 <4 <2 <4 < 12 <2 <2 <21 <7 MCD 04/10/13 < 28 287 +/- 43 <2 < 2 < 8 <2 <3 <3 <5 < 222 <2 <2 < 120 < 38 MCD 04/11/13 < 42 351 +/- 73 < 3 < 4 < 11 <3 <6 <4 <8 < 278 <3 < 3 < 179 < 47 MCD 04/12/13 < 38 187 +/- 63 < 2 < 3 < 8 <2 <4 <4 <6 < 260 <2 <2 <148 < 36 MCD 04/13/13 < 35 299 +/- 71 < 2 < 4 < 9 <3 <5 <4 <6 < 218 <2 <2 < 140 < 42 MCD 04/14/13 < 42 385 +/- 74 < 3 <4 < 11 <3 <6 <4 <7 < 238 <3 <3 < 157 < 51 MCD 04/15/13 < 31 310 +/- 58 < 2 < 3 < 8 <2 <4 <3 <5 < 167 < 2 <2 < 111 <34 MCD 04/16/13 < 37 304 +/- 81 < 3 <4 < 11 <3 <7 <4 <8 < 190 <3 <3 < 149 <45 MCD 04/17/13 < 41 376 +/- 69 < 3 < 4 < 10 <2 <6 <4 <8 < 200 <3 <3 < 138 < 37 MCD 04/18/13 < 36 361 +/-67 <3 <4 <9 <3 <5 <4 <7 < 160 <3 <3 < 119 <34 MCD 04/19/13 < 39 319 +/- 69 < 3 < 3 <9 <2 <5 <4 <7 < 157 <2 <3 < 120 < 28 MCD 04/20/13 < 32 265 +/- 60 < 2 < 3 <7 <2 <5 <3 <6 < 107 <2 <2 <82 < 33 MCD 04/21/13 < 25 245 +/- 44 <2 < 3 <6 <2 .<4 <3 <4 < 96 <2 <2 <73 < 22 MCD 04/22/13 < 33 265 +/- 61 < 3 < 3 < 8 <3 <5 <3 <6 < 122 <2 <2 <93 < 23 MCD 04/23/13 < 37 167 +/- 68 < 3 < 3 <7 <3 <5 <4 <7 < 114 <2 <3 <96 <24 MCD 04/24/13 < 35 257 +/- 70 < 3 < 3 < 9 <3 <5 <4 <6 < 97 <2 <3 <86 < 26 MCD 04/25/13 < 39 286 +/- 77 < 3 < 4 < 11 <3 <7 <4 <8 < 104 <3 <3 <97 < 38 MCD 04/26/13 < 30 257 +/- 57 <2 < 3 < 7 <2 <5 <3 <6 < 75 <2 <2 <71 < 22 MCD 04/27/13 < 40 241 +/- 66 < 2 <4 < 10 <3 <6 <4 <7 < 344 <2 <3 < 193 < 58 MCD 04/28/13 < 35 370 +/- 75 < 3 <3 < 9 <3 <5 <4 <7 < 75 <3 <3 <79 < 22 MCD 04/29/13 < 31 301 +/- 70 < 2 <3 < 8 <2 <5 <4 <6 < 69 <3 <3 <68 < 21 MCD 04/30/13 < 25 248 +/- 51 < 2 < 2 < 5 <2 <3 <2 <4 < 47 <2 <2 <48 < 15 MCD 05/01/13 < 19 243 +/- 40 < 1 < 2 < 5 <1 <3 <2 <3 < 36 <1 <1 <39 < 11 MCD 05/02/13 < 24 198 +/- 56 < 2 < 2 < 6 <2 <4 <3 <4 <44 <2 <2 <46 < 13 BOLDED VALUES INDICATE LLD WAS NOT MET DUE TO THE AGE OF THE SAMPLE AT TIME OF RECEIPT AT THE LABORATORY

TABLE B-1I.2 CONCENTRATIONS OF GAMMA EMITTERS IN SURFACE WATER SAMPLES COLLECTED IN THE VICINITY OF OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER + 2 SIGMA SITE COLLECTION Be-7 K-40 Mn-54 Co-58 Fe-59 Co-60 Zn-65 Nb-95 Zr-95 1-131 Cs-134 Cs-137 Ba-140 La-140 DATE MCD 05/03/13 < 25 181 +/- 50 < 2 < 2 < 6 <2 <4 <3 <4 <43 <2 <2 <47 < 12 MCD 05/04/13 < 23 262 +/- 53 < 2 < 2 < 5 <2 <4 <2 <4 < 33 <2 <2 <38 < 13 MCD 05/05/13 < 20 244 +/- 43 < 2 < 2 < 5 <2 <3 <2 <4 < 28 <2 <2 <34 < 10 MCD 05/06/13 < 23 250 +/- 68 < 2 < 2 < 6 <2 <4 <2 <5 < 29 <2 <2 <36 < 14 MCD 05/07/13 < 18 242 +/- 46 < 2 < 2 < 4 <2 <3 <2 <4 < 22 <1 <2 <29 <9 MCD 05/08/13 < 25 274 +/- 60 < 2 < 3 < 7 <2 <5 <3 <5 < 26 <2 <2 <36 <11 MCD 05/09/13 < 26 263 +/- 55 < 2 < 3 < 5 <2 <4 <3 <4 < 27 <2 <2 <37 < 10 MCD 05/10/13 < 20 260 +/- 52 < 2 < 2 < 5 <2 <3 <2 <4 < 21 *<2 <2 <29 <8 MCD 05/11/13 < 24 294 +/- 60 < 2 < 3 < 6 <2 <4 <3 <5 < 22 <2 <2 <32 <11 MCD 05/12/13 < 14 250 +/- 42 < 1 < 1 < 3 <1 <3 <2 <2 < 13 <1 <1 <20 <5 MCD 05/13/13 < 17 269 +/- 53 < 2 <2 <4 <1 <3 <2 <3 < 15 <2 <2 <22 <7 MCD 05/14/13 < 19 258 +/- 59 < 2 < 2 < 4 <2 <3 <2 <4

  • 15 <1 <2 <23 <7 MCD 05/15/13 < 29 639 +/- 68 < 2 < 3 < 6 <3 <5 <3 <5 < 22 <2 <3 <34 <9 MCD 05/16/13 < 20 272 +/- 50 < 2 < 2 < 4 <2 <4 <2 <3
  • 13 <2 <2 <22 <7 MCD 05/17/13 < 20 240 +/- 81 < 2 < 2 < 5 <2 <5 <3 <4
  • 13 <2 <2 <25 <8 MCD 05/18/13 < 19 232 +/- 54 < 2 < 2 < 4 <2 <4 <2 <3 <11 <1 <2 <21 <7 MCD 05/19/13 < 28 252 +/- 77 < 3 < 3 < 7 <3 <6 <3 <6
  • 14 <2 <3 <27 < 10 MCD 05120/13 < 25 287 +/- 64 < 2 < 3 < 6 <3 <5 <3 <5
  • 14 <2 <2 <24 <7 MCD 05/21/13 < 23 322 +/- 68 < 2 < 2 < 5 <2 <4 <3 <4 <11 <2 <2 <21 <6 MCD 05/22/13 < 22 267 +/- 61 < 2 < 2 < 5 <3 <5 <3 <4 < 10 <2 <3 <21 <7 MCD 05/23/13 < 17 262 +/- 43 < 2 < 2 < 4 <1 <3 <2 <3 <8 <1 <2 <15 <5 MCD 05/24/13 < 27 268 +/- 69 < 3 < 3 < 5 <3 <5 <3 <5 < 12 <2 <3 <22 <6 MCD 05/25/13 < 24 235 +/- 66 <2 <2 <5 <2 <4 <3 <4
  • 10 <2 <3 <20 <5 MCD 05/26/13 < 20 314 +/- 64 < 2 < 2 < 5 <3 <4 <2 <4 <8 <2 <2 <17 <6 MCD 05/27/13 < 26 403 +/- 86 < 3 < 3 < 5 <3 <6 <3 <6 <9 <2 <3 <19 <6 MCD 05128/13 < 21 275 +/- 58 < 2 < 2 < 4 <2 <5 <2 <4 <7 <2 <2 <17 <4 MCD 05129/13 < 31 270 +/- 95 < 3 < 3 < 8 <4 <8 <4 <6 <9 <3 <3 <22 <7 MCD 05130/13 < 27 313 +/- 83 < 3 < 3 < 7 <3 <6 <3 <6 <8 <3 <3 <21 <5 MCD 05/31/13 < 34 229 +/- 87 < 3 < 4 < 10 <3 <6 <4 <6 < 141 < 2 < 3 < 114 < 33 MCD 06101/13 < 28 283 +/- 72 < 2 < 2 < 7 <2 <5 <4 <6 < 116 <2 <2 <98 < 29 MCD 06102/13 < 28 271 +/- 66 < 2 < 2 < 7 <2 <4 <3 <5 < 108 <2 <2 <88 < 22 MCD 06/03/13 < 35 421 +/- 81 < 2 < 3 < 9 <2 <5 <4 <6 < 115 <2 <2 <89 < 24 MCD 06/04/13 < 36 223 +/- 82 < 3 < 4 < 10 <3 <6 <4 <8 < 106 <2 <3 <98 < 30 MCD 06/05/13 < 19 279 +/- 49 < 2 < 2 < 4 <1 <3 <2 <4 < 81 <1 <1 <62 < 18 MCD 06/06/13 < 28 237 +/- 74 < 2 < 3 < 6 <2 <4 <3 <5 < 104 <2 <2 <70 < 28 MCD 06107/13 < 26 281 +/- 70 < 2 < 2 < 6 <2 <4 <3 <5 < 80 <2 <2 <79 < 23 MCD 06108/13 < 25 301 +/- 66 < 2 < 2 < 5 <2 <4 <3 <4 < 70 <2 <2 <69 < 16 MCD 06/09/13 < 30 310 +/- 73 < 2 < 3 < 7 <3 <5 <3 <5 < 75 <2 <2 <76 < 25 BOLDED VALUES INDICATE LLD WAS NOT MET DUE TO THE AGE OF THE SAMPLE AT TIME OF RECEIPT AT THE LABORATORY

TABLE B-11.2 CONCENTRATIONS OF GAMMA EMITTERS IN SURFACE WATER SAMPLES COLLECTED IN THE VICINITY OF OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA SITE COLLECTION Be-7 K-40 Mn-54 Co-58 Fe-59 Co-60 Zn-65 Nb-95 Zr-95 1-131 Cs-134 Cs-137 Ba-140 La-140 DATE MCD 06/10/13 < 31 214 +/- 84 < 2 < 3 < 8 <3 <5 <4 <5 < 77 <2 <2 <72 < 29 MCD 06/11/13 < 30 394 +/- 80 < 2 < 3 < 7 <2 <4 <3 <5 < 79 <2 <2 <75 < 22 MCD 06/12/13 < 26 317 +/- 64 < 2 < 3 < 7 <2 <4 <3 <5 < 59 <2 <2 <64 < 18 MCD 06/13/13 < 29 311 +/- 79 <2 <3 <6 <2 <5 <3 <5 < 62 <2 <2 <56 < 14 MCD 06/14/13 < 22 181 +/- 69 < 2 < 2 < 5 <2 <3 <2 <3 < 35 <1 <2 <40 < 10 MCD 06/15/13 < 18 248 +/- 43 < 1 < 2 < 5 <1 <3 <2 <3 < 36 <1 <1 <36 < 11 MCD 06/16/13 < 28 259 +/- 76 < 2 < 3 <7 <2 <5 <3 <5 < 51 <2 <2 <54 < 16 MCD 06/17/13 < 28 241 +/- 67 < 2 < 3 <6 <2 <4 <3 <5 < 43 <2 <2 <47 < 14 MCD 06/18/13 < 21 263 +/- 64 < 2 < 2 <5 <2 <3 <2 <4 < 33 <2 <2 <38 < 11 MCD 06/19/13 < 26 346+/-77 <2 <3 <7 <3 <5 <3 <5 < 40 <2 <2 <48 < 10 MCD 06/20/13 < 44 304 +/- 109 < 4 <4 < 9 <4 <8 <5 <7 < 53 <3 <4 <67 < 21 MCD 06/21/13 < 32 357 +/- 76 <3 < 3 < 8 <3 <6 <3 <7 <43 <2 <3 <49 < 14 MCD 06/22/13 < 31 301 +/- 72 < 3 < 3 < 6 <3 <6 <4 <6 < 38 <2 <3 <48 < 12 MCD 06/23/13 < 31 271 +/- 62 < 3 < 3 < 7 <2 <6 <4 <6 < 33 <3 <3 <42 < 14 MCD 06/24/13 < 24 221 +/- 62 < 2 < 2 < 5 <2 <4 <3 <5 < 22 <2 <2 <34 < 12 MCD 06/25/13 < 35 299 +/- 71 < 3 < 3 < 8 <3 <6 <4 <6 < 32 <3 <3 <45 < 10 MCD 06/26/13 < 31 322 +/- 73 <3 < 3 < 8 <3 <6 <3 <6 < 31 <2 <3 <42 < 13 MCD 06/27/13 < 28 291 +/- 86 < 3 < 3 < 7 <3 <5 <3 <6 < 26 <2 <3 <42 < 12 MCD 06/28/13 < 32 235 +/- 88 < 3 < 4 < 8 <3 <6 <4 <7 < 24 <3 <3 <44 < 13 MCD 06/29/13 < 32 422 +/- 78 < 3 < 3 < 8 <3 <5 <3 <6 < 25 .< 3 <3 <37 < 10 MCD 06/30/13 < 31 296 +/- 68 < 3 < 3 <6 <3 <6 <3 <6 < 22 <3 <3 <36 <8 MCD 07/01/13 < 21 247 +/- 58 < 2 < 2 < 6 <2 <5 <3 <5 < 14 <2 <2 <25 <9 MCD 07102/13 < 20 189 +/- 74 < 2 < 2 < 5 <2 <4 <3 <4 < 14 <2 <2 <24 <8 MCD 07/03/13 < 22 229 +/- 60 < 2 < 3 < 5 <3 <5 <3 <4 < 14 <2 <3 <24 <7 MCD 07104/13 < 21 231 +/- 77 < 2 < 2 < 5 <2 <5 <2 <4 < 12 <2 <2 <24 <8 MCD 07/05/13 < 28 255 +/- 85 <3 < 3 < 7 <3 <5 <3 <6 < 15 <3 <3 <29 <9 MCD 07/06/13 < 28 364+/-79 <3 <3 <7 <3 <6 <3 <6 < 12 <3 <3 <29 <9 MCD 07/07/13 < 28 274 +/- 75 <3 < 3 < 6 <3 <5 <3 <5 < 13 <3 < 3 <25 <7 MCD 07/08/13 < 23 256 +/- 60 <2 < 3 < 6 <3 <5 <3 <4 <8 <2 <3 <19 <7 MCD 07/09/13 < 14 244 +/- 39 < 1 < 1 < 3 <1 <3 <2 <3 <6 <1 <1 <13 <4 MCD 07/10/13 < 21 249 +/- 69 < 2 < 2 < 5 <2 <5 <3 <4 <9 <2 <2 <18 <5 MCD 07/11/13 < 20 257 +/- 62 < 2 < 2 < 5 <2 <4 <2 <4 <8 <2 <2 <17 <4 MCD 07/12/13 < 24 318 +/- 48 < 2 < 2 < 6 <2 <4 <3 <4 < 89 <2 < 2 <74 < 23 MCD 07/13/13 < 39 299 +/- 71 < 3 < 3 < 11 <3 <6 <4 <7 < 121 <3 < 3 < 103 < 24 MCD 07/14/13 < 34 222 +/- 70 < 3 < 4 < 8 <3 <5 <4 <7 < 109 <2 <3 <81 < 28 MCD 07/15/13 < 22 311 +/-68 <2 <2 <6 <2 <4 <3 <5 < 67 <2 <2 <58 < 14 MCD 07/16/13 < 42 376 +/- 81 < 4 < 4 < 11 <3 <7 <5 <8 < 102 <3 < 3 < 101 < 39 MCD 07/17/13 < 37 303 +/- 76 < 3 < 4 < 10 <3 <7 <4 <7 < 93 <3 <3 <91 < 31 BOLDED VALUES INDICATE LLD WAS NOT MET DUE TO THE AGE OF THE SAMPLE AT TIME OF RECEIPT AT THE LABORATORY

TABLE B-11.2 CONCENTRATIONS OF GAMMA EMITTERS IN SURFACE WATER SAMPLES COLLECTED IN THE VICINITY OF OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA SITE COLLECTION Be-7 K-40 Mn-54 Co-58 Fe-59 Co-60 Zn-65 Nb-95 Zr-95 1-131 Cs-134 Cs-137 Ba-140 La-140 DATE MCD 07/18/13 < 23 345 +/- 64 < 2 < 3 < 6 <2 <4 <3 <5 <54 <2 <2 <55 <15 MCD 07/19/13 < 39 294 +/- 72 < 3 <4 < 10 <3 <6 <4 <8 < 83 <3 <3 <80 < 23 MCD 07/20/13 < 22 295 +/- 69 < 2 < 2 < 6 <2 <4 <2 <4 < 43 <2 <2 <49 < 11 MCD 07/21/13 < 20 341 +/-51 <2 <2 <4 <1 <3 <2 <3 < 36 <1 <2 <37

  • 12 MCD 07/22/13 < 29 327 +/- 67 < 2 < 3 <6 <2 <4 <3 <5 <54 <2 <2 <57
  • 13 MCD 07/23/13 < 25 237 +/- 76 < 2 < 3 < 6 <2 <4 <3 <5 < 44 <2 <2 <47
  • 13 MCD 07/24/13 < 20 295 +/- 64 < 2 < 2 < 4 <2 <3 <3 <4 < 31 <2 <2 <36
  • 12 MCD 07/25/13 < 29 369 +/- 86 < 3 <3 < 10 <3 <6 <3 <6 <43 <2 <2 <52
  • 18 MCD 07/26/13 < 29 429 +/- 78 < 3 < 3 < 6 <3 <5 <4 <6 < 37 <3 <2 <50
  • 15 MCD 07/27/13 < 26 300 +/- 68 < 2 < 3 < 6 <2 <4 <3 <5 < 32 <2 <2 <36 <11 MCD 07/28/13 < 23 280 +/- 75 < 2 < 3 < 6 <2 <4 <3 <5 <32 <2 < 2 <43 < 12 MCD 07/29/13 < 22 304 +/- 66 < 2 < 2 < 5 <2 <4 <2 <4 < 23 < 2 <2 <28 <7 MCD 07/30/13 < 18 301 +/- 47 < 2 < 2 < 4 <1 <3 <2 <3 < 12 <2 <2 <20 <6 MCD 07/31/13 < 18 311 +/-66 <2 <2 <4 <2 <4 <2 <4
  • 13 <2 <2 <24 <7 MCD 08/01/13 < 20 229:+/- 58 < 2 < 2 < 4 <2 <4 <2 <4
  • 12 <2 <2 < 20 < 5 MCD 08/02/13 < 18 233 +/- 57 < 2 < 2 < 5 <3 <4 <2 <4 <11 r2 <2 <20 <6 MCD 08/03/13 < 24 293 +/- 69 < 3 <3 < 6 <3 <6 <3 <5
  • 13 <2 <3 <25 <9 MCD 08/04/13 < 23 305 +/- 64 < 2 < 2 < 6 <2 <4 <2 <4
  • 12 <2 <2 <21 <7 MCD 08/05/13 < 21 242 +/- 55 < 2 <2 < 4 <2 <4 <2 <4
  • 10 <2 <2 <19 <5 MCD 08/06/13 < 22 204 +/- 65 < 2 < 2 < 5 <2 <5 <2 <4
  • 10 <2 <2 <20 <5 MCD 08/07/13 < 16 260 +/- 50 < 2 <2 < 4 <2 <4 <2 <3 <7 <2 <2 <15 <4 MCD 08/08/13 < 20 349 +/- 50 < 2 <2 < 4 <2 <4 <3 <4 <9 <2 <2 <19 <6 MCD 08/09/13 < 24 264 +/- 65 < 3 <3 < 6 <2 <5 <3 <5 <11 <2 <3 <21 <6 MCD 08/10/13 < 26 200 +/- 66 < 3 < 3 < 6 <3 <5 <3 <5 < 10 <3 <3 <20 <6 MCD 08/11/13 < 23 337 +/- 68 < 2 < 3 < 5 <3 <5 <2 <5 <8 <2 <2 <19 <6 MCD 08/12/13 < 30 263 +/- 87 < 4 < 4 < 8 <4 <8 <4 <7 < 10 < 3 <4 <23 <8 MCD 08/13/13 < 28 259 +/- 86 < 3 < 3 < 7 <3 <5 <3 <6 <9 <3 <3 <23 <7 MCD 08/14/13 < 27 296 +/- 77 < 3 < 3 < 6 <3 <6 <3 <6 <8 <3 < 3 <19 < 6 MCD 08/15/13 < 26 263 +/- 75 < 3 < 2 < 6 <3 <5 <3 <5 <7 <3 < 3 <17 <4 MCD 08/16/13 < 21 299 +/- 60 < 2 < 2 < 5 <2 <5 <3 <4 <5 <2 <2 <14 <4 MCD 08/17/13 < 14 308 +/- 53 < 2 < 2 < 3 <1 <3 <2 <2 <4 <1 <2 <10 <3 MCD 08/18/13 < 21 269 +/- 75 < 2 < 2 < 5 <3 <4 <3 <4 <5 <2 <2 <14 <4 MCD 08/19/13 < 19 302 +/- 69 < 2 < 2 <4 <2 <4 <2 <4 <5 <2 <2 <12 <3 MCD 08/20/13 < 36 261 +/- 70 < 2 < 3 < 9 <2 <5 <3 <6 < 506 < 2 < 2 < 235 < 62 MCD 08/21/13 < 35 340+/-71 <2 <3 <8 <2 <3 <3 <6 < 425 < 2 < 2 < 225 < 53 MCD 08/22/13 < 43 278 +/- 107 < 3 < 4 < 12 <3 <6 <5 <9 < 557 < 2 < 3 < 235 < 61 MCD 08/23/13 < 37 429 +/- 91 < 3 <4 < 13 <3 <5 <4 <7 < 466 <3 < 2 < 235 < 75 MCD 08/24/13 < 30 256 +/- 70 < 2 < 3 < 8 <2 <3 <3 <5 < 415 <2 <2 < 177 < 50 BOLDED VALUES INDICATE LLD WAS NOT MET DUE TO THE AGE OF THE SAMPLE AT TIME OF RECEIPT AT THE LABORATORY

TABLE B-11.2 CONCENTRATIONS OF GAMMA EMITTERS IN SURFACE WATER SAMPLES COLLECTED IN THE VICINITY OF OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA SITE COLLECTION Be-7 K-40 Mn-54 Co-58 Fe-59 Co-60 Zn-65 Nb-95 Zr-95 1-131 Cs-134 Cs-137 Ba-140 La- 140 DATE MCD 08/25/13

  • 27 258 +/- 63 < 2 < 3 < 8 <2 <4 <3 <5 < 331 <2 < 2 < 143 < 47 MCD 08/26/13
  • 23 274 +/- 57 < 2 < 2 < 6 <2 <3 <2 <5 < 235 < 1 < 1 < 124 < 42 MCD 08/27/13 <34 230 +/- 82 < 3 <4 < 10 <2 <5 <4 <7 < 328 < 2 < 2 < 205 < 57 MCD 08/28/13
  • 25 239 +/- 56 < 2 < 2 < 7 <1 <4 <2 <5 < 217 <1 < 1 <127 <34 MCD 08/29/13
  • 25 210 +/-63 <2 <2 <6 <2 <3 <3 <5 < 236 < 1 < 2 < 135 < 29 MCD 08/30/13
  • 27 314 +/- 66 < 2 < 3 < 6 <2 <4 <3 <5 < 206 < 2 < 2 < 116 < 40 MCD 08/31/13
  • 30 392 +/- 74 <2 <3 <7 <2 <4 <3 <5 < 228 <2 < 2 < 118 <34 MCD 09/01/13
  • 30 305 +/- 62 < 2 < 3 < 8 <2 <4 <3 <6 < 226 < 2 < 2 < 123 < 33 MCD 09/02/13
  • 29 268 +/- 70 < 2 < 3 < 8 <2 <4 <3 <4 < 195 <2 < 2 < 122 <40 MCD 09/03/13 < 24 267 +/- 62 < 2 < 2 < 7 <2 <4 <2 <4 < 147 <2 <2 <93 < 23 MCD 09/04/13 < 22 311 +/-67 <1 <2 <6 <2 <4 <3 <4 < 128 <1 <2 <93 < 32
  • MCD 09/05/13
  • 32 280 +/- 83 < 2 < 3 <2 <5 <3 < 155 <2 <2 < 37

< 9 <7 < 125 MCD 09/06/13

  • 30 395 +/- 77 < 2 < 2 < 8 <2 <4 <3 <5 < 152 < 2 < 2 < 114 < 31 MCD 09/07/13
  • 25 286 +/- 59 < 2 < 2 < 6 <2 <3 <3 <4 < 116 <2 <2 <87 < 21 MCD 09/08/13
  • 27 315 +/-66 <2 <2 <6 <2 <4 <3 <5 < 112 <2 <2 <88 < 23 MCD 09/09/13
  • 21 291 +/-157 < 1 < 2 < 5 <1 <3 <2 <4 < 80 <1 <2 <70 < 22 MCD 09/10/13
  • 32 255 +/- 76 < 2 <3 < 10 <2 <5 <4 <5 < 124 <2 <2 <98 < 28 MCD 09/11/13
  • 27 254 +/- 76 < 2 < 3 < 8 <2 <5 <3 <5 < 110 <2 <2 <89 < 18 MCD 09/12/13
  • 24 283 +/- 66 < 2 < 2 < 6 <2 <4 <3 <4 < 80 <2 <2 <64 < 24 MCD 09/13/13
  • 32 264 +/- 96 < 3 <4 < 10 <3 <6 <4 <7 < 102 <3 <3 <93 < 33 MCD 09/14/13 < 29 356 80 < 2 < 3 < 7 <2 <4 <3 <6 <84 <2 <2 <80 < 20 MCD 09/15/13 < 26 371 +/-79 < 2 < 3 < 7 <2 <4 <3 <5 < 76 <2 <2 <66 < 25 MCD 09/16/13 < 27 294 86 < 2 < 3 < 8 <2 <5 <3 <6 < 71 <2 <2 <76 < 23

.MCD 09/17/13

  • 27 296 79 < 2 < 3 < 7 <3 <5 <3 <5 < 81 <2 <2 <70
  • 15 MCD 09/18/13 < 26 342 72 < 2 < 3 < 6 <2 <5 <2 <4 < 65 <2 <2 <58 < 18 MCD 09/19/13
  • 23 317 +/-64 <2 <2 <6 <2 <4 <2 <4 <54 <2 <2 <56 < 14 MCD 09120/13
  • 30 248 +/- 92 < 3 < 3 < 8 <3 <4 <3 <6 < 63 <2 <2 <64 < 24 MCD 09/21/13
  • 27 395 +/- 79 < 2 < 2 <5 <2 <4 <2 <4 < 52 <2 <2 <54 <13 MCD 09/22/13
  • 27 330 +/- 77 < 2 < 3 <6 <2 <4 <3 <5 <44 <2 <2 <50
  • 15 MCD 09123/13
  • 28 340 +/- 89 < 2 < 3 < 6 <2 <4 <3 <5 <48 <2 <2 <54
  • 16 MCD 09/24/13 *19 317 +/- 63 < 2 < 2 < 6 <2 <3 <2 <4 < 32 <2 <2 <35 <11 MCD 09/25/13
  • 28 344 +/- 86 < 2 < 3 < 6 <3 <4 <3 <5 < 51 <2 <2 <59 < 10 MCD 09/26/13
  • 20 379 +/- 81 < 2 < 2 <5 <2 <4 <2 <4 < 30 <2 <2 <41 < 13 MCD 09/27/13
  • 29 229 +/- 94 < 2 <3 < 8 <3 <5 <3 <6 < 39 <2 <3 <53 <9 MCD 09/28/13
  • 27 364 +/- 87 < 2 < 3 < 6 <2 <4 <3 <6 < 38 <2 <2 <44 < 11 MCD 09/29/13
  • 25 337 +/- 83 < 2 < 3 < 6 <2 <4 <2 <4 < 26 <2 <2 <36 <7 MCD 09/30/13 < 26 295 +/- 78 < 2 <3 < 6 <2 <4 <3 <5 < 31 <2 <2 <40 < 10 MCD 10/01/13
  • 21 325 +/-:67 < 2 <2 < 5 <2 <4 <2 <4 < 20 <2 <2 <29 <7 BOLDED VALUES INDICATE LLD WAS NOT MET DUE TO THE AGE OF THE SAMPLE AT TIME OF RECEIPT AT THE LABORATORY

TABLE B-II.2 CONCENTRATIONS OF GAMMA EMITTERS IN SURFACE WATER SAMPLES COLLECTED IN THE VICINITY OF OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA SITE COLLECTION Be-7 K-40 Mn-54 Co-58 Fe-59 Co-60 Zn-65 Nb-95 Zr-95 1-131 Cs-134 Cs-137 Ba-140 La-140 DATE MCD 10/02/13 < 24 258 +/- 79 < 2 < 2 <5 <2 <4 <2 <4 < 23 <2 <2

  • 38 <7 MCD 10/03/13 < 22 294 +/- 72 < 2 < 2 <5 <2 <3 <2 <5 < 19 <2 <2
  • 28 <10 MCD 10/04/13 < 20 373 +/- 67 < 2 < 2 <5 <2 <4 <2 <4 < 16 <1 <2
  • 25 <8 MCD 10/05/13 < 27 294 +/- 93 < 2 < 3 <7 <3 <5 <3 <5 < 20 <2 <2 < 35 <9 MCD 10/06/13 < 22 445 +/- 85 < 2 < 2 <5 <2 <4 <3 <4 < 17 <2 <2
  • 31 <6 MCD 10/07/13 < 20 346 +/- 77 < 2 < 2 <5 <2 <4 <2 <4
  • 14 <2 <2
  • 23 <6 MCD 10/08/13 < 20 368 +/- 71 < 2 < 2 <5 <2 <3 <2 <4
  • 14 <2 <2
  • 23 <6 MCD 10/09/13 < 21 329 +/- 63 < 1 < 2 <4 <1 <3 <2 <3 <11 <1 <2 < 19 <5 MCD 10/10/13 < 42 265 +/- 78 < 2 < 4 <14 <2 <5 <4 <6
  • 550 <2 <2 < 265 < 82 MCD 10/11/13 < 29 122 +/- 67 < 2 < 3 <9 <2 <4 <3 <5
  • 405 <2 <2 < 192 < 55 MCD 10/12/13 < 36 251 +/- 73 < 2 < 3 <10 <2 <4 <4 <6 < 465 <2 <2 < 202 < 56 MCD 10/13/13 < 27 254 +/- 59 < 2 < 3 <7 <2 <3 <3 <6 < 341 <2 <2 < 157 < 50 MCD 10/14/13 < 31 369 +/- 76 < 2 < 3 <9 <2 <4 <4 <5 < 361 <2 <2 < 186 < 59 tz MCD 10/15/13 < 30 236 +/- 66 < 2 < 3 <8 <2 <3 <3 <5 < 381 <1 <2 < 207 < 58 MCD 10/16/13 < 35 263 +/- 83 < 2 < 4 <9 <2 <5 <4 <7 < 422 <2 <2 < 216 < 65 MCD 10/17/13 < 30 265 +/- 67 < 2 < 3 <9 <2 <4 <3 <5 < 352 <2 <2 < 177 < 59 MCD 10/18/13 < 29 272 +/- 60 < 2 < 2 <7 <1 <3 <3 <5 < 355 <2 <2 < 166 <43 MCD 10/19/13 < 27 243 +/- 65 < 2 < 3 <9 <2 <4 <3 <4 < 343 <2 <2 < 175 <48 MCD 10/20/13 < 27 132 +/- 61 < 1 < 2 <6 <1 <4 <2 <5 < 287 <1 <1 < 124 < 44 MCD 10/21/13 < 32 257 +/- 49 <2 < 3 <6 <2 <4 <3 <5 < 319 <2 <2 < 164 < 39 MCD 10/22/13 < 28 246 +/- 67 <2 < 2 <7 <2 <3 <3 <5 < 252 <1 <2 < 139 < 49 MCD 10/23/13 < 25 273 +/- 65 <2 < 2 <7 <2 <3 <3 <4 < 238 <2 <2 < 128 <44 MCD 10/24/13 < 47 419 +/- 104 < 3 < 5 <11 <3 <6 <5 <8 < 398 <3 <3 < 215 < 61 MCD 10/25/13 < 24 103 +/- 58 < 1 < 2 <5 <1 <3 <3 <4 < 163 <1 <1 < 98 < 30 MCD 10/26/13 < 24 243 +/- 61 < 2 < 2 <6 <1 <4 <3 <4 < 184 <1 <2 < 107 < 29 MCD 10/27/13 < 41 464 +/- 99 < 2 < 4 <9 <2 <5 <4 <7 < 289 <2 <3 < 159 <45 MCD 10/28/13 < 26 337 +/- 77 < 2 < 3 <7 <2 <4 <3 <5 < 66 <2 <2 < 64 < 17 MCD 10/29/13 < 26 322 +/- 68 < 2 < 2 <6 <2 <4 <3 <5 < 58 <2 <2 < 52 < 14 MCD 10/30/13 < 20 294 +/- 59 < 1 < 2 <4 <2 <3 <2 <4 < 41 <1 <2
  • 40 < 12 MCD 10/31/13 < 25 348 +/- 75 < 2 < 3 <5 <1 <3 <2 <4 < 52 <1 <2 < 44
  • 12 MCD 11/01/13 < 18 340 +/- 70 < 2 < 2 <4 <2 <4 <2 <4 < 33 <1 <2 < 39
  • 14 MCD 11/02/13 < 22 305 +/- 65 < 2 < 2 <6 <2 <4 <2 <4 < 41 <2 <2 < 45 <12 MCD 11/03/13 < 19 116 +/- 62 < 2 < 2 <4 <2 <3 <2 <4 < 26 <1 <2
  • 28 < 11 MCD 11/04/13 < 22 307 +/- 64 < 2 < 2 <6 <2 <3 <3 <4 < 47 <2 <2 < 47 < 14 MCD 11/05/13 < 19 304 +/- 63 < 2 < 2 <5 <2 <4 <2 <3 < 41 <1 <2
  • 42 < 13 MCD 11/06/13 < 18 333 +/- 57 <2 < 2 <4 <2 <3 <2 <4 < 32 <1 <2 < 35 < 11 MCD 11/07/13 < 26 340 +/- 77 <2 < 3 <7 <2 <5 <3 <5 < 42 <2 <2
  • 52 < 18 MCD 11/08/13 < 17 121 +/- 58 < 2 < 2 <5 <2 <3 <2 <3 < 30 <1 <2
  • 32 < 10 BOLDED VALUES INDICATE LLD WAS NOT MET DUE TO THE AGE OF THE SAMPLE AT TIME OF RECEIPT AT THE LABORATORY

TABLE B-II.2 CONCENTRATIONS OF GAMMA EMITTERS IN SURFACE WATER SAMPLES COLLECTED IN THE VICINITY OF OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA SITE COLLECTION Be-7 K-40 Mn-54 Co-58 Fe-59 Co-60 Zn-65 Nb-95 Zr-95 1-131 Cs-134 Cs-137 Ba-140 La-140 DATE MCD 11/09/13 < 21 322 +/- 72 <2 < 2 < 5 <2 <3 <2 <4 <34 <2 <2 <35 <9 MCD 11/10/13 < 20 363 +/- 63 < 1 < 2 < 4 <2 <3 <2 <4 < 30 <2 <2 <34 <8 MCD 11/11/13 < 21 270 +/- 75 <2 < 2 < 5 <1 <4 <2 <4 < 32 <2 <2 <38 <11 MCD 11/12/13 < 21 262 +/- 74 <2 <2 < 5 <2 <4 <2 <4 < 31 <2 <2 <39 <10 MCD 11/13/13 < 18 298 +/- 70 < 2 < 2 < 5 <2 <4 <2 <4 < 26 <2 <2 <31 <10 MCD 11/14/13 < 16 279 +/- 57 < 1 < 2 < 4 <2 <3 <2 <3 < 17 <1 <1 <24 <:9 MCD 11/15/13 < 23 315 +/- 72 < 2 < 2 < 6 <2 <4 <3 <4 < 37 <2 <2 <44 <11 MCD 11/16/13 < 20 293 +/- 50 < 2 < 2 < 4 <2 <3 <2 <4 < 32 <1 <1 <35 < 10 MCD 11/17/13 < 20 275 +/- 59 < 2 < 2 < 5 <2 <4 <2 <4 < 33 <1 <2 <36 < 11 MCD 11/18/13 < 18 261 +/- 59 < 2 < 2 < 5 <2 <3 <2 <3 < 29 <1 <2 <33 <11 MCD 11/19/13 < 24 346 +/- 82 < 2 < 3 < 6 <2 <4 <3 <5 < 30 <2 <2 <39 <11 MCD 11/20/13 < 14 156 +/- 56 < 1 < 2 < 4 <1 <3 <1 <3 < 18 <1 <1 <24 <8 MCD 11/21/13 < 34 216 +/- 64 < 3 < 3 < 7 <3 <5 <3 <6 < 117 <2 <2 <91 < 27 MCD 11/22/13 < 41 216 +/- 87 < 3 < 5 < 11 <4 <7 <4 <9 < 122 <3 <3 <119 <34 MCD 11/23/13 < 37 351 +/- 76 < 3 < 3 < 7 <2 <5 <3 <7 < 120 <2 <2 <97 < 28 MCD 11/24/13 < 39 277 +/- 63 < 3 < 4 < 9 <3 <6 <4 <7 < 114 <3 <3 <92 < 23 MCD 11/25/13 < 20 269 +/- 60 < 1 < 2 < 4 <1 <4 <2 <3 < 51 <1 <2 <46 < 17 MCD 11/26/13 < 37 228 +/- 77 < 3 < 3 < 9 <3 <6 <4 <7 < 96 <2 <3 <90 < 23 MCD 11/27/13 < 33 242 +/- 70 < 3 < 3 < 7 <3 <5 <4 <6 < 87 <2 <3 <80 < 23 MCD 11/28/13 < 40 274 +/- 85 < 3 < 4 < 9 <3 <6 <5 <7 < 87 <3 <3 <89 < 22 MCD 11/29/13 < 33 370 +/- 80 < 3 < 4 < 9 <2 <6 <4 <6 < 69 <2 <3 <81 < 20 MCD 11/30/13 < 23 377 +/- 71 < 2 < 2 < 5 <2 <3 <2 <4 <45 <2 <2 <48 < 14 MCD 12/01/13 < 26 264 +/- 72 < 2 < 2 < 6 <2 <4 <3 <5 <44 <2 <2 <47 <15 MCD 12/02/13 < 31 321 +/-68 <2 <3 <7 <2 <6 <3 <6 <54 <2 <2 <60 <11 MCD 12/03/13 < 24 232 +/- 72 < 2 < 2 < 5 <2 <4 <3 <4 < 39 <2 <2 <47 < 12 MCD 12/04/13 < 28 256 +/- 78 < 2 < 2 < 6 <2 <4 <3 <5 <46 <2 <2 <48 < 11 MCD 12/05/13 < 19 227 +/- 64 < 2 < 3 < 5 <2 <4 <2 <4 < 35 <2 <2 <42 <13 MCD 12/06/13 < 25 198 +/- 84 < 2 < 3 < 7 <2 <4 <3 <6 < 44 <2 <2 <50 < 15 MCD 12/07/13 < 20 272 +/- 67 < 2 < 2 < 5 <1 <4 <2 <4 < 35 <2 <2 <37

  • 10 MCD 12/08/13 < 61 354 +/- 95 < 5 < 6 < 14 <5 <10 <7 <12 < 87 <5 <5 <103 < 29 MCD 12/09/13 < 23 222 +/- 69 < 2 < 2 < 5 <2 <4 <3 <4 < 28 <2 <2 <40 < 10 MCD 12/10/13 < 17 248 +/- 57 < 1 < 2 < 5 <1 <3 <2 <3 < 20 <1 <2 <25 <8 MCD 12/11/13 < 21 217 +/- 63 < 2 < 2 < 5 <2 <4 <2 <4 < 23 <2 <2 <34 < 10 MCD 12/12/13 < 18 201 +/- 62 < 1 < 2 < 5 <1 <3 <2 <3 < 18 <1 <1 <25 <7 MCD 12/13/13 < 21 177 +/- 77 < 2 < 2 < 6 <2 <4 <2 <5 < 21 <2 <2 <32 < 11 MCD 12/14/13 < 21 258 +/- 70 < 2 < 2 < 4 <2 <3 <2 <4 < 19 <2 <2 <27 <6 MCD 12/15/13 < 19 216 +/- 60 < 2 < 2 < 4 <2 <3 <2 <3 < 16 <2 <2 <24 <7 MCD 12/16/13 < 20 286 +/- 62 < 2 < 2 < 4 <2 <4 <2 <4 < 17 <2 <2 <27 <7 BOLDED VALUES INDICATE LLD WAS NOT MET DUE TO THE AGE OF THE SAMPLE AT TIME OF RECEIPT AT THE LABORATORY

TABLE B-1I.2 CONCENTRATIONS OF GAMMA EMITTERS IN SURFACE WATER SAMPLES COLLECTED IN THE VICINITY OF OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA SITE COLLECTION Be-7 K-40 Mn-54 Co-58 Fe-59 Co-60 Zn-65 Nb-95 Zr-95 1-131 Cs-134 Cs-137 Ba-140 La- 140 DATE MCD 12/17/13 < 26 278 +/- 75 <2 < 3 <6 <2 < 4 <3 <5 < 66 <2 <2 <66 < 15 MCD 12/18/13 < 24 272+/-77 <2 <2 <6 <2 <4 <3 <5 < 58 <2 <2 <62 < 13 MCD 12/19/13 < 24 241 +/-70 <2 <3 <5 <2 <4 <3 <5 < 52 <2 <2 <51 < 15 MCD 12/20/13 < 23 328 +/- 63 < 1 <2 <5 <2 <3 <2 <4 < 42 <1 <2 <44 < 11 MCD 12/21/13 < 23 277 +/- 62 < 2 < 2 <6 < 2 < 3 <3 <4 <43 <2 <2 <45 < 14 MCD 12/22/13 < 23 319 +/-65 <2 <2 <5 <2 <4 <2 <4 < 37 <1 <2 <41 <8 MCD 12/23/13 < 21 296 +/- 66 < 2 < 2 <5 < 2 < 4 <2 <4 < 35 <1 <2 <38 < 13 MCD 12/24/13 < 20 310 +/-65 <2 <2 <4 <2 <3 <2 <4 < 32 <2 <2 <38 < 10 MCD 12/25/13 < 17 248 +/- 58 < 1 < 1 < 4 < 1 < 3 <2 <3 < 21 <1 <2 <27 <7 MCD 12/26/13 < 23 418 +/-72 <2 <2 <6 <2 <4 <2 <4 < 35 <2 <2 <43 < 12 MCD 12/27/13 < 18 274 +/-64 <2 <2 <4 <2 <4 <2 <4 < 26 <2 <2 <31 <8 SW-i 01/02/13 < 42 228 +/- 65 <4 <4 < 10 <4 < 8 <5 <8 < 26 <4 <4 <44 < 11 SW-i 01/09/13 < 43 <47 <5 < 5 < 12 < 5 < 10 <6 <9 < 16 <4 <5 <34 < 12 SW-i 01/16113 < 29 247 +/- 62 < 2 < 3 <5 <2 < 5 <3 <5 < 50 <2 <2 <55 < 13 00 SW-i 01/23/13 < 13 229 +/- 38 < 1 < 1 <3 < 1 <2 <2 <3 < 14 <1 <1 <21 <5 SW-i 01/30/13 < 21 305 +/- 56 < 2 < 2 < 5 <2 < 4 <2 <4 < 15 <2 <2 <24 <6 SW-i 02/06/13 < 32 210+/-57 <4 <3 <8 <3 <7 <4 <6 < 13 <3 <3 <27 <9 SW-i 02/13/13 < 15 319+/-55 <1 <2 <4 <1 <2 <2 <2 < 14 <1 <1 <20 <5 Sw-i 02/20/13 < 31 325 +/- 87 < 3 < 3 <8 < 3 <6 <4 <6 < 17 <3 <3 <31 <9 SW-i 02/27/13 < 26 329 +/-73 <2 <3 <5 <2 <5 <3 <5 <9 <3 <3 <21 <5 SW-i 03/06/13 < 22 344 +/-68 <3 <2 <5 <3 <5 <3 <5 <5 <2 <3 <13 <4 Sw-i 03/13/13 < 23 207 +/- 46 < 2 < 3 <6 <2 <4 <3 <5 < 33 <2 <2 <40 < 12 SW-i 03/20/13 < 28 318 +/-63 <2 <3 <6 <2 <6 <3 <5 < 23 <2 <3 <32 < 11 SW-i 03/27/13 < 27 285 +/- 68 < 3 <3 <6 <2 < 5 <3 <5 < 13 <2 <3 <25 <7 SW-i 04/03/13 < 22 282 +/- 71 <2 <2 <5 <3 < 5 <3 <4 <6 <2 <3 <14 <4 SW-i 04/10/13 < 42 314+/-64 <3 <4 <11 <2 <5 <5 <7 < 476 < 2 < 3 < 229 < 58 SW-i 04/17/13 < 39 284 +/- 73 < 3 <4 < 11 <3 <5 <4 <7 < 272 <2 < 3 < 166 < 50 Sw-i 04/24/13 < 31 271 +/-63 <2 <3 <8 <3 <5 <4 <6 < 135 <2 < 3 < 108 < 33 SW-i 05/01/13 < 18 257 +/- 44 < 1 <2 <4 < 1 <3 <2 <3 < 45 <1 <1 <42 < 14 SW-i 05/08/13 < 22 337 +/- 64 < 2 < 2 <6 < 3 <4 <3 <4 < 31 <2 <2 <39 < 14 SW-i 05/15/13 < 24 289 +/- 59 <2 < 3 <6 <2 <4 <3 <5 <25 <2 <2 <34 <9 SW-i 05/22/13 < 28 343 +/-67 <3 <3 <7 <3 <5 <3 <5 < 15 <2 <3 <28 <9 SW-i 05/29/13 < 30 432 +/- 86 <3 <3 <7 <3 <6 <3 <6 < 10 <3 <3 <23 <7 SW-i 06/05/13 < 26 249 +/-64 <2 <3 <7 <2 <4 <3 <5 < 134 < 2 < 2 < 95 < 30 SW-i 06/12/13 < 28 222 +/- 78 < 2 < 3 < 8 <2 <4 <3 <6 < 88 < 2 <2 < 75 < 22 SW-i 06/19/13 < 25 298 +/-66 <2 <2 <5 <2 <3 <3 <4 < 46 < 2 < 2 < 50 < 13 SW-i 06/26/13 < 24 300 +/- 59 < 2 <3 <6 <2 <4 <3 <5 < 27 < 2 < 2 < 37 < 10 SW-i 07/03/13 < 18 275 +/- 61 <2 <2 <4 <2 <4 <2 <4 < 12 < 2 <2 < 21 <6 BOLDED VALUES INDICATE LLD WAS NOT MET DUE TO THE AGE OF THE SAMPLE AT TIME OF RECEIPT AT THE LABORATORY

TABLE B-11.2 CONCENTRATIONS OF GAMMA EMITTERS IN SURFACE WATER SAMPLES COLLECTED IN THE VICINITY OF OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA SITE COLLECTION Be-7 K-40 Mn-54 Co-58 Fe-59 Co-60 Zn-65 Nb-95 Zr-95 1-131 Cs-134 Cs-137 Ba-140 La-140 DATE SW-1 07/10/13 < 17 320 +/- 56 <2 < 2 < 4 <2 <4 <2 <3 <7 <2 <2 <15 <5 SW-1 07/17/13 < 19 130 +/- 56 <2 < 2 < 4 <2 <3 <2 <4 < 56 < 1 < 2 < 53 < 12 SW-1 07/24/13 < 30 286 +/- 101 < 3 <4 <9 <3 <6 <3 <7 < 50 < 3 < 3 < 61 < 18 SW-1 07/31/13 < 29 426 +/- 86 <2 < 3 < 6 <3 <5 <3 <6 < 30 < 2 < 3 < 36 < 13 SW-1 08/07/13 < 19 305 +/- 65 < 2 < 2 < 5 <2 <4 <2 <4 < 12 <2 <2 <23 <7 Sw-1 08/14/13 < 23 256 +/- 72 <2 < 2 < 5 <2 <4 <2 <5 <8 <2 <2 <18 <5 SW-1 08/21/13 < 34 289 +/- 64 <2 <3 < 10 <2 <4 <3 <5 < 945 <2 < 1 < 287 < 79 SW-1 08/28/13 < 33 255 +/- 68 <2 < 3 < 9 <2 <4 <3 <5 < 519 <2 < 2 < 188 < 65 SW-1 09/04/13 < 22 350 +/- 55 < 2 < 2 < 7 <2 <4 <2 <5 < 236 < 1 < 1 < 124 < 35 Sw-1 09/11/13 < 31 214 +/- 83 < 2 < 4 < 8 <2 <5 <3 <6 < 173 < 2 < 2 < 119 < 39 Sw-1 09/18/13 < 27 447+/-81 <2 <2 <6 <2 <3 <3 <5 < 99 < 2 < 2 < 84 < 15 SW-1 09/25/13 < 21 307 +/- 68 < 2 < 2 < 5 <2 <4 <2 <4 <45 <1 <2 <45 < 10 SW-1 10/02/13 < 23 256 +/- 73 < 2 < 2 < 5 <2 <4 <2 <4 < 28 < 2 < 2 < 36 <8 F0 SW-1 10/09/13 < 17 270 +/- 62 < 1 < 2 < 4. <2 <3 <2 <3 <12 <1 <1 <20 <6 Sw-1 10/16/13 < 33 257 +/- 67 < 2 < 3 < 7 <1 <4 <3 <5 < 459 < 2 < 2 < 203 < 53 SW-1 10/23/13 < 29 316 +/- 72 < 2 < 3 < 7 <2 <4 <3 <5 < 272 < 2 < 2 < 144 < 45 Sw-1 10/30/13 < 27 354 +/- 74 < 2 < 3 < 7 <2 <4 <3 <6 < 151 < 2 < 2 < 123 < 29 Sw-1 11106/13 < 26 301 +/- 57 < 2 < 2 < 6 <2 <4 <3 <5 < 92 < 2 < 2 < 75 < 18 Sw-1 11/13/13 < 23 289 +/- 60 < 2 < 2 < 5 <2 <4 <2 <4 <54 <2 <2 <46 < 15 Sw-1 11/20/13 < 21 277 +/- 76 < 2 < 2 < 5 <2 <4 <2 <4 <25 <2 <2 <34 < 11 Sw-1 11/27/13 < 24 275 +/- 66 < 2 < 2 < 5 <2 <4 <2 <4 < 74 < 2 < 2 < 60 < 20 SW-1 12/04/13 < 24 222 +/- 83 < 2 < 3 < 7 <2 <4 <3 <6 < 52 < 2 < 2 < 56 < 15 SW-1 12/11/13 < 25 286 +/- 73 < 2 < 2 < 5 <2 <4 <2 <4 < 28 <2 < 2 < 36 <9 Sw-1 12/19/13 < 29 260 +/- 79 < 2 < 3 <6 <2 <4 <3 <5 < 62 < 2 < 2 < 68 < 14 Sw-1 12/27/13 < 22 315 +/-66 <2 <2 <4 <2 <4 <3 <4 < 29 <2 < 2 < 34 < 10 SW-2 04/11/13 < 45 239 +/- 66 < 5 < 5 < 10 <5 <9 <6 <8 < 14 < 5 < 5 < 31 < 11 SW-3 04/11/13 < 31 <35 <3 <3 <7 <3 <8 <4 <7 <8 <3 <4 <22 < 10 BOLDED VALUES INDICATE LLD WAS NOT MET DUE TO THE AGE OF THE SAMPLE AT TIME OF RECEIPT AT THE LABORATORY

TABLE B-II.3 CONCENTRATIONS OF HARD-TO-DETECTS IN SURFACE WATER SAMPLES COLLECTED AS PART OF THE RADIOLOGICAL GROUNDWATER PROTECTION PROGRAM, OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA SITE COLLECTION Am-241 Cm-242 Cm-243/244 Pu-238 Pu-239/240 U-234 U-235 U-238 Fe-55 Ni-63 PERIOD NONE FOR 2013

,0

TABLE B-Ill.1 CONCENTRATIONS OF TRITIUM IN PRECIPITATION WATER SAMPLES COLLECTED AS PART OF THE RADIOLOGICAL GROUNDWATER PROTECTION PROGRAM, OYSTER CREEK GENERATING STATION, 2013 RESULTS IN UNITS OF PCI/LITER +/- 2 SIGMA COLLECTION SITE DATE H-3 2 01/10/13 < 181 2 04/11/13 < 167 2 07/11/13 < 197 2 10/07/13 < 197 3 01/10/13 < 180 3 04/11/13 < 167 3 07/11/13 < 194 3 10/07/13 < 199 4 01/10/13 < 184 4 04/11/13 < 166 4 07/11/13 < 187 4 10/07/13 < 200 5 02/12/13 < 178 5 04/11/13 < 165 5 07/11/13 < 193 5 10/07/13 < 197 6 01/10/13 < 183 6 04/11/13 < 167 6 07/11/13 < 186 6 10/07/13 < 198 B-3I