Annual Radioactive Effluent Release Report Revised 2008 Oyster Creek Nuclear Generating Station 1
Revised 2008 Annual Radioactive Effluent Release Report ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT January 1, 2008 through December 31, 2008 EXELON GENERATION COMPANY, LLC OYSTER CREEK NUCLEAR GENERATING STATION DOCKET NO. 50-219 (Oyster Creek Generating Station)
DOCKET NO. 72-15 (Independent Spent Fuel Storage Facility)
Submitted to The United States Nuclear Regulatory Commission Pursuant to Renewed Facility Operating License DPR-16 2
Revised 2008 Annual Radioactive Effluent Release Report TABLE OF CONTENTS SECTION
- 1.
Introduction
- 2.
Supplemental Information A
Regulatory Limits B
Effluent Concentration Limits C
Average Energy D
Measurements and Approximations of Total Radioactivity E
Abnormal Releases F
Revisions to the ODCM G
Radiation Effluent Monitors Out of Service More Than 30 Days H
Changes to the Process Control Plan I
Releases from the Independent Spent Fuel Storage Facility PAGE 6
6 6
7 7
7 8
9 9
9 9
Appendix A - Effluent and Waste Disposal Summary Appendix B - Solid Waste and Irradiated Fuel Shipments Appendix C - Radiological Impact to Man Appendix D - Meteorological Data 10 17 22 24 3
Revised 2008 Annual Radioactive Effluent Release Report EXECUTIVE
SUMMARY
Effluents are strictly monitored to ensure that radioactivity released to the environment is as low as reasonably achievable and does not exceed regulatory limits. Effluent control includes the operation of monitoring systems, in-plant and environmental sampling and analyses programs, quality assurance programs for effluent and environmental programs, and procedures covering all aspects of effluent and environmental monitoring.
Both radiological environmental and effluent monitoring indicate that the operation of Oyster Creek Nuclear Generating Station (OCNGS) does not result in significant radiation exposure of people or the environment surrounding OCNGS and is well below the applicable levels set by the Nuclear Regulatory Commission (NRC) and the Environmental Protection Agency (EPA).
There were no liquid radioactive effluent releases above ODCM LLDs during 2008.
Therefore there was no dose due to radiological liquid releases. Utilizing gaseous effluent data, the maximum hypothetical dose to any individual in the southeast sector of the plant (sector of predominant wind direction) was calculated using a mathematical model, which is based on the methods defined by the U.S. Nuclear Regulatory Commission. These methods accurately determine the types and quantities of radioactive materials being released to the environment.
The maximum hypothetical calculated organ dose (thyroid) from iodines and particulates to any individual due to gaseous effluents was 3.58E-3 mRem (0.00358 mRem), which was approximately 0.024 percent of the annual limit. The maximum calculated gamma air dose in the UNRESTRICTED AREA due to noble gas effluents was 3.66E-3 mRem (0.00366 mRem), which was 0.0366 percent of the annual limit.
The total maximum hypothetical organ dose (thyroid) received by any individual from gaseous effluents from OCNGS for the reporting period due to all radiological effluents is 3.58E-3 mRem (0.00358 mRem). This value is more than 83,000 times lower than the dose the average individual in the Oyster Creek area received from background radiation, including that from radon during the same time period. The background radiation dose averages approximately 300 mRem per year in the Central New Jersey area, which includes approximately 200 mRem/year from naturally occurring radon gas and100 mRem from background radiation.
The Independent Spent Fuel Storage Installation (ISFSI) is a closed system and the only exposure would be due to direct radiation. This includes iodines, particulates and noble gases. Based on offsite TLD readings, dose due to direct radiation from the ISFSI was less than 1 mRem for 2008. Because it is a sealed unit, no radioactive material was released.
Additionally, comparison of environmental sampling results to iodine and particulate gaseous effluents released, showed no radioactivity attributable to the operation of OCNGS. Both elevated and ground-level release paths were considered in this review, 4
Revised 2008 Annual Radioactive Effluent Release Report with total iodines released of 1.58 mCi and total particulates with half-lives greater than 8 days released of 0.339 mCi (1 mCi is one/one-thousandth of a Ci).
Joint Frequency Tables of meteorological data, per Pasquill Category, as well as for all stability classes, are included. All data was collected from the on-site Meteorological Facility. Data recoveries for the 380-foot data and the 33-foot data were 97.9 percent and 97.8 percent, respectively. The UFSAR commits to Regulatory Guide (RG) 1.23 for Meteorological Facility data recovery. RG 1.23 requires data recovery of at least 90%
on an annual basis.
5
Revised 2008 Annual Radioactive Effluent Release Report
- 1.
Introduction In accordance with the reporting requirements of Technical Specification 3.6.E.1 applicable during the reporting period, this report summarizes the effluent release data for Oyster Creek Generating Station for the period January 1, 2008 through December 31, 2008. This submittal complies with the format described in Regulatory Guide 1.21, "Measuring, Evaluating and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water Cooled Nuclear Power Plants", Revision 1, June, 1974.
Meteorological data was reported in the format specified in Regulatory Guide 1.23, Revision 1, "Meteorological Monitoring Programs For Nuclear Power Plants".
All vendor results were received and included in the report calculations. Therefore the 2008 report is complete.
- 2.
Supplemental Information A.
Regulatory Limits Limit Units Receptor ODCM and 10 CFR 50, Appendix I Desiqn Objective Limits
- 1. Noble Gases:
- a.
< 500
< 3000
- b.
<5
<10
- c.
<10
< 20
- d.
<5
<15 mrem/Yr mrem/Yr mRad mRad mRad mRad Total Body Skin Air Gamma Air Beta Air Gamma Air Beta mrem mrem Total Body (Gamma)
Skin (Beta)
- 2. lodines, Tritium, Particulates with Half Life > 8 days:
- a.
< 1500 mrem/Yr Any Organ
- b.
<7.5
- c.
<15 mrem mrem Any Organ Any Organ ODCM Control 3.11.2.1 Quarterly air dose limits ODCM Control 3.11.2.2 Yearly air dose limits ODCM Control 3.11.2.2 10 CFR 50, Appendix I,Section II.B.2(b)
ODCM Control 3.11.2.1 Quarterly dose limits ODCM Control 3.11.2.3 Yearly dose limits ODCM Control 3.11.2.3 ODCM Control 3.11.1.1 Quarterly dose limits ODCM Control 3.11.1.2 Yearly dose limits ODCM Control 3.11.1.2
- 3. Liquid Effluents
- a.
Concentration 10 CFR 20, Appendix B, Table 2 Column 2
- b.
< 1.5
<5
- c.
<3
<10 mrem mrem mrem mrem Total Body Any Organ Total Body Any Organ 6
Revised 2008 Annual Radioactive Effluent Release Report B.
Effluent Concentration Limits:
Gaseous dose rates rather than effluent concentrations are used to calculate permissible release rates for gaseous releases. The maximum permissible dose rates for gaseous releases are defined in ODCM Controls 3.11.2.1.
The Effluent Concentration Limit (ECL) specified in 10 CFR 20, Appendix B, Table 2, Column 2 for identified nuclides, were used to calculate permissible release rates and concentrations for liquid release per the Oyster Creek Offsite Dose Calculation Manual Control 3.11.1.1. The total activity concentration at the Route 9 bridge for all dissolved or entrained gases was limited to < 2E-04 lCi/mL.
C. Average Energy ( E):
The Oyster Creek ODCM limits the instantaeneous dose equivalent rates due to the release of noble gases to less than or equal to 500 mrem/year to the total body and less than or equal to 3000 mrem/year to the skin. The average beta and gamma energies (T) of the radionuclide mixture in releases of fission and activation gases as described in Regulatory Guide 1.21, "Measuring, Evaluation, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants," may be used to calculate doses in lieu of more sophisticated software. The Oyster Creek radioactive effluent program employs the methodologies presented in U.S. NRC Regulatory Guide 1.109 "Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR Part 50, Appendix I,"
Revision 1, October 1977 and NUREG-0133, "Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants, October 1978. Therefore, average energies are not applicable to Oyster Creek.
D. Measurements and Approximations of Total Radioactivity:'
- 1.
Fission and Activation Gases The method used for Gamma Isotopic Analysis is the Canberra Gamma Spectroscopy System with a gas Marinelli beaker. Airborne effluent gaseous
'activity was continuously monitored and recorded in accordance with ODCM Table 4.11.2.1.2-1. Additional grab samples were taken from the stack RAGEMS sample point and ground-level release sample points and analyzed at least monthly to determine the isotopic mixture of noble gas activity released for the month. The data from the noble gas radiation monitor were analyzed to report net noble gas effluent activity. If activity was found in the grab isotopic analysis, the isotopic mixture for the Noble Gas Monitor was determined from that isotopic mixture.
- 2.
Particulates and lodines The method used for Gamma Isotopic Analysis is the Canberra Gamma Spectroscopy System with a particulate filter (47 mm) and/or charcoal cartridge, respectively. Particulate and iodine activity was continuously sampled and analyzed in accordance with ODCM Table 4.11.2.1.2-1. Charcoal and particulate samples are taken from the stack RAGEMS sample point and ground-level release sample points and analyzed at least weekly to determine the total activity released from the plant based on the highest vent flow rates recorded for the sampling period.
7
Revised 2008 Annual Radioactive Effluent Release Report
- 3.
Liquid Effluents During 2008, there were no radiological liquid releases. Since there were no liquid discharges in 2008, there was no dose attributable to liquid effluents.
- 4.
Tritium in Gaseous Effluents:
Air from stack effluents was passed through a desiccant column and distilled to remove the tritiated water collected. An aliquot of the water from the distillate was analyzed using a liquid scintillation counter.
- 5.
Composite Samples and Lower Limit of Detection (LLD)
Particulate air samples were composited monthly and analyzed for gross alpha, Sr-89 and Sr-90. These composites are submitted to an offsite vendor laboratory for analysis. The ODCM required lower limit of detection for liquid and airborne releases are as follows:
Liquid:
LLD Principal Gamma Emitters (Mn-54, Fe-59, Co-58, Co-60, Zn-65, 1-131, Ce-141, Cs-134, Cs-137) 5E-07 pCi/mI Principal Gamma Emitters (Mo-99, Ce-144) 1E-05 pCi/mI Dissolved and Entrained Gases 1 E-05 pCi/mI H-3 1E-05 pCi/ml Gross Alpha 1E-07 pCi/mI Sr-89, Sr-90 5E-08 pCi/mI Fe-55 1E-06 pCi/mI Airborne LLD Principal Gamma Emitters (Kr-87, Kr-88, Xe-133, Xe-133m, Xe-135, Xe-138) 1E-04 pCi/ml H-3 1E-06 pCi/ml 1-131 1 E-12 pCi/ml 1-133 1E-10 pCi/mI Principal Gamma Emitters (Mn-54, Fe-59, Co-58, Co-60, Zn-65, Mo-99, Cs-134, Cs-137, Ce-141, Ce-144) 1E-11 pCi/ml Gross Alpha 1E-11 pCi/ml Sr-89, Sr-90 1E-11 pCi/ml
- 6.
Estimated Total Error Present Procedure CY-AA-170-2100, Estimated Errors of Effluent Measurements, provides the methodology to obtain an overall estimate of the error associated with radioactive effluents.
E. Abnormal Releases:
There were no abnormal releases during 2008.
8
Revised 2008 Annual Radioactive Effluent Release Report F.
Revisions to the ODCM There were no revisions to the ODCM during 2008.
G. Radiation Effluent Monitors Out of Service More Than 30 Days Per ODCM Control 3.11, "Radioactive Liquid Effluent Monitoring Instrumentation" and Table 3.3.3.11-1 Radioactive Gaseous Effluent Monitoring Instrumentation",
instrumentation requires:
With less than the minimum number of radioactive gaseous effluent monitoring instrumentation channels OPERABLE, take the ACTION shown in Table 3.3.3.11-1.
Restore the inoperable instrumentation to OPERABLE status within the time specified in the ACTION or explain in the next Annual Radioactive Effluent Release Report why this inoperability was not corrected within the time specified.
The following is a discussion of instrumentation out of service for greater than 30 days:
The Service Water radiation monitor was out of service from 09/25/2008 to 12/31/2008 due to inoperable instrumentation. An investigation revealed that the monitor could not be repaired and that new components had to be manufactured.
H. Changes to the Process Control Plan Revisions 6 and 7 of the Process Control Plan (PCP) (RW-AA-100) were approved June 2008 and December 2008 respectively. Complete copies of the procedures, along with a summary of changes are included in this mailing.
- 1. Releases from the Independent Spent Fuel Storage Facility The Independent Spent Fuel Storage Installation (ISFSI) is a closed system and the only exposure would be due to direct radiation. This includes iodines, particulates, and noble gases. Based on offsite TLD readings, dose due to direct radiation from the ISFSI was less than lmRem for 2008. Because it is a sealed unit, no radioactive material was released.
9
Revised 2008 Annual Radioactive Effluent Release Report Appendix A Effluent and Waste Disposal Summary 10
Revised 2008 Annual Radioactive Effluent Release Report LIST OF TABLES PAGE Table A - 1 Gaseous Effluents - Summation of All Releases 13 Table A - 2 Gaseous Effluents for Release Point-Elevated 14 Table A - 3 Gaseous Effluents for Release Point - Ground Level 15 Table A - 4 Liquid Effluents - Summation of All Releases 16 11
Revised 2008 Annual Radioactive Effluent Release Report (Page Intentionally Left Blank) 12
Revised 2008 Annual Radioactive Effluent Release Report TABLE A -1 GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES A.
FISSION AND ACTIVATION GASSES PERIOD 2008 Est. Total Units Qtr 1 Qtr 2 Qtr 3 Qtr 4 Erroral Error %
- 1. Total Release Ci 1.54E0 1.98E0 3.33E0 7.03E-1 25
- 2. Average Release Rate for Period uCi/sec 1.96E-1 2.52E-1 4.19E-1 8.84E-2
- 3. Dose m rad 3.81 E-5 3.13E-5 7.83E-5 3.57E-3
- Gamma Air Dose
- Beta Air Dose mrad 1.94E-5 2.85E-5 4.95E-5 4.57E-3
- 4. Percent of ODCM Limit 7.62E-4 6.26E-4 1.57E-3 7.14E-2
- Gamma Air Dose
- Beta Air Dose 1.94E-4 2.85E-4 4.95E-4 4.57E-2 B.
IODINES Est. Total Units Qtr 1 Qtr 2 Qtr 3 Qtr 4 Error %
- 1. Total 131 Ci 1.58E-4 2.03E-4 3.13E-5 3.30E-5 25
- 2. Average Release Rate for Period uCi/sec 2.01 E-5 2.58E-5 3.94E-6 4.15E-6 C.
PARTICULATES I
Est. Total Units Qtr 1 Qtr 2 Qtr 3 Qtr 4 Erroral Error %
- 1. Particulates with T 1/2 > 8 days Ci 1.11E-4 1.04E-4 2.61E-5 9.80E-5 25
- 2. Average Release Rate for Period uCi/sec 1.42E-5 1.32E-5 3.28E-6 1.23E-5
- 3. Gross Alpha Radioactivity Ci
<LLD
<LLD
<LLD
<LLD D.
TRITIUM Units Qtr 1 Qtr 2 Qtr 3 Qtr 4 Est. Total Error %
25
.1. Total Release Ci 5.37E+00 5.91E+00 1.01E+01 6.24E+00
- 2. Average Release Rate for Period UCi/sec 6.82E-01 7.52E-01 1.27E+00 7.85E-01 E.
Iodine 131 & 133, Tritium & Particulate Units Qtr 1 Qtr 2 Qtr 3 Qtr 4
- 1. Organ Dose mrem 8.65E-4 1.33E-3 5.OOE-4 1.17E-3
- 2. Percent of ODCM Limit 1.15E-2 1.77E-2 6.67E-3 1.56E-2
13
Revised 2008 Annual Radioactive Effluent Release Report TABLE A - 2 GASEOUS EFFLUENTS FOR RELEASE POINT -
ELEVATED PERIOD 2008
- 1.
FISSION AND ACTIVATION GASSES Nuclide Released Continuous Mode Units Qtr 1 Qtr 2 Qtr 3 Qtr 4 KR-85 Ci
<LLD
<LLD
<LLD
<LLD KR-85M Ci
<LLD
<LLD
<LLD
<LLD KR-87 Ci
<LLD
<LLD
<LLD
<LLD KR-88 Ci
<LLD
<LLD
<LLD
<LLD XE-131M Ci
<LLD
<LLD
<LLD
<LLD XE-133 Ci
<LLD
<LLD
<LLD
<LLD XE-133M Ci
<LLD
<LLD
<LLD
<LLD XE-135 Ci 1.54E0 1.98E0 3.33E0 8.76E-2 XE-1 35M Ci
<LLD
<LLD
<LLD
<LLD XE-1 38 Ci
<LLD
<LLD
<LLD
<LLD Total for Period Ci 1.54E0 1.98E0 3.33E0 8.76E-2
- 2.
IODINES Nuclide Released Continuous Mode Units Qtr 1 Qtr 2 Qtr 3 Qtr 4 1-131 Ci 1.58E-4 2.03E-4 3.13E-5 1.59E-5 1-133 Ci 5.34E-4 4.25E-4 1.75E-4 2.17E-5 Total for Period Ci 6.92E-4 6.28E-4 2.06E-4 3.76E-5
- 3.
PARTICULATES (T 1/2 > 8 DAYS)
Nuclide Released Continuous Mode Units Qtr 1 Qtr 2 Qtr 3 Qtr 4 MN-54 Ci 1.51 E-5 1.87E-5
<LLD
<LLD FE-59 Ci
<LLD
<LLD
<LLD
<LLD CO-58 Ci
<LLD
<LLD
<LLD
<LLD CO-60 Ci
<LLD
<LLD
<LLD 7.17E-6 ZN-65 Ci
<LLD
<LLD
<LLD
<LLD SR-89 Ci 9.64E-5 8.51 E-5 2.61 E-5 6.42E-5 SR-90 Ci
<LLD
<LLD
<LLD
<LLD ZR-95 Ci
<LLD
<LLD
<LLD
<LLD NB-95 Ci
<LLD
<LLD
<LLD
<LLD MO-99 Ci
<LLD
<LLD
<LLD
<LLD CS-1 34 Ci
<LLD
<LLD
<LLD
<LLD CS-1 37 Ci
<LLD
<LLD
<LLD
<LLD CE-1 41 Ci
<LLD
<LLD
<LLD
<LLD CE-144 Ci
<LLD
<LLD
<LLD
<LLD BA-140 Ci
<LLD
<LLD
<LLD 2.66E-5 Total for Period Ci 1.11 E-4 1.04E-4 2.61 E-5 9.80E-5 14
Revised 2008 Annual Radioactive Effluent Release Report TABLE A - 3 GASEOUS EFFLUENTS FOR RELEASE POINT -
GROUND LEVEL PERIOD 2008
- 1.
FISSION AND ACTIVATION GASSES Nuclide Released Continuous Mode Units Qtr 1 Qtr 2 Qtr 3 Qtr 4 AR-41 Ci
<LLD
<LLD
<LLD
<LLD KR-85M Ci
<LLD
<LLD
<LLD
<LLD KR-87 Ci
<LLD
<LLD
<LLD
<LLD KR-88 Ci
<LLD
<LLD
<LLD
<LLD XE-1 33 Ci
<LLD
<LLD
<LLD
<LLD XE-133M Ci
<LLD
<LLD
<LLD
<LLD XE-135 Ci
<LLD
<LLD
<LLD 6.15E-1 XE-1 35M Ci
<LLD
<LLD
<LLD
<LLD XE-1 38 Ci
<LLD
<LLD
<LLD
<LLD Total for Period Ci
<LLD
<LLD
<LLD 6.15E-1
- 2.
IODINES Nuclide Released Continuous Mode Units Qtr I Qtr 2 Qtr 3 Qtr 4 1-131 Ci
<LLD
<LLD
<LLD 1.71 E-5 1-133 Ci
<LLD
<LLD
<LLD
<LLD Total for Period Ci
<LLD
<LLD
<LLD 1.71 E-5
- 3.
PARTICULATES (T 1/2 > 8 DAYS)
Nuclide Released Continuous Mode Units Qtr 1 Qtr 2 Qtr 3 Qtr 4 MN-54 Ci
< LLD
< LLD
< LLD
< LLD
< LLD
< LLD
< LLD CO-58 Ci
< LLD
< LLD
< LLD
< LLD
< LLD
< LLD
< LLD ZN-65 Ci
< LLD
< LLD
< LLD
< LLD SR-89 Ci
< LLD
< LLD
< LLD
< LLD
< LLD
< LLD
< LLD ZR-95 Ci
< LLD
< LLD
< LLD
< LLD NB-95 Ci
< LLD
< LLD
< LLD
< LLD
< LLD
< LLD
< LLD CS-134 Ci
< LLD
< LLD
< LLD
< LLD
< LLD
< LLD
< LLD CE-141 Ci
< LLD
< LLD
< LLD
< LLD CE-144 Ci
< LLD
< LLD
< LLD
< LLD Total for Period Ci
< LLD
< LLD
< LLD
< LLD 15
Revised 2008 Annual Radioactive Effluent Release Report TABLE A - 4 LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES PERIOD 2008 A.
FISSION AND ACTIVATION PRODUCTS Est. Total Units Qtr 1 Qtr 2 Qtr 3 Qtr 4 Error %
- 1. Total release (not including tritium, Ci N/A N/A N/A N/A N/A gasses & alpha)
- 2. Average diluted concentration during uCi/ml N/A N/A N/A N/A batch discharge for the period
- 3. Dose
- Whole Body mrem N/A N/A N/A N/A
- Organ mrem N/A N/A N/A N/A
- 4. % of ODCM Limit - Whole Body Dose*
N/A N/A N/A N/A
- Organ Dose*
N/A N/A N/A N/A B. TRITIUM Est. Total Units Qtr 1 Qtr 2 Qtr 3 Qtr 4 Error Error %
- 1. Total Release Ci N/A N/A N/A N/A N/A
- 2. Average diluted concentration during uCi/ml N/A N/A N/A N/A batch discharge for the period
N/A N/A N/A N/A C. DISSOLVED AND ENTRAINED GASSES Est. Total Units Qtr 1 Qtr 2 Qtr 3 Qtr 4 Erroral Error %
- 1. Total release Ci N/A N/A N/A N/A N/A
- 2. Average diluted concentration during uCi/ml N/A N/A N/A N/A batch discharge for the period 3 %of ODCM Limit - ECL N/A N/A N/A N/A D. GROSS ALPHA RADIOACTIVITY Units Qtr 1 Qtr 2 Qtr 3 Qtr 4 Est. Total Error %
- 1. Total release Ci N/A N/A N/A N/A N/A
- 2. Average diluted concentration during uCi/mI N/A N/A N/A N/A batch discharge for the period Units Qtr 1 Qtr 2 Qtr 3 Qtr 4 Est. Total Error %
E. Volume of waste released (prior to Liters N/A N/A N/A N/A N/A dilution)
F. Volume of dilution water used during Liters N/A N/A N/A N/A N/A period I
Percent of limit includes tritium.
16
Revised 2008 Annual Radioactive Effluent Release Report Appendix B Solid Waste and Irradiated Fuel Shipments 17
Revised 2008 Annual Radioactive Effluent Release Report (Page Intentionally Left Blank) 18
Revised 2008 Annual Radioactive Effluent Release Report Solid waste shipped offsite for burial or disposal (not irradiated fuel) 1/1/08 - 12/31/08
- 1. Type of waste Type of waste Uni 12 Month Period Estimated Error %
- a. Spent resin, filters sludges, evaporator bottoms, etc m3 2.14E1 25%
Ci 4.54E1
- b. Dry compressible waste, contaminated equipment, etc. m3 1 4.43E2 25%
ICi I 1.94E-1
- c. Irradiated components, control rods, etc.
Im 3
1.52E-121 25%
1Ci I 2.07E4 I
- d. Other (Describe) m 1.18E1 25%
Oil Filter Media Ci 5.65E1
- 2. Estimate of Major Nuclide Composition (By Waste Type)
Category A - Spent Resin, Filters, Sludges, Evaporator Bottoms, etc.
Waste Class Waste Class Waste Class A
Percent B
Percent C
Percent Isotope Curies
- Abundance Curies
- Abundance Curies*
Abundance Co-60 1.46E+00 34.8 1.29E+01 31.4 1.OOE+04 48.3 Cs-137 1.26E+00 30.1 1.93E+01 47.0 1.89E-02 9.13E-05 Fe-55 1.03E+00 24.6 5.99E+00 14.6 9.48E+03 45.8 Mn-54 2.15E-01 5.128 1.07E+00 2.60 2.62E+02 1.27 Zn-65 1.01 E-01 2.409 2.42E-01 0.589
<LLD N/A C-14 6.73E-02 1.605 7.88E-01 1.92 1.46E+00 7.06E-03 Ni-63 2.88E-02 0.687 3.89E-01 0.946 9.43E+02 4.58 Cs-1 34 1.21 E-02 0.289 2.70E-01 0.657
<LLD N/A H-3 4.14E-03 0.099 7.27E-02 0.177 7.OOE-01 3.38E-03 Sr-90 3.84E-03 0.092 5.91E-02 0.144 5.91E-05 2.86E-7 Ag-110m 3.51E-03 0.084
<LLD N/A
<LLD N/A Ce-144 3.48E-03 0.083 1.62E-02 0.040 1.58E-04 7.64E-07 Pu-241 2.39E-03 0.057
<LLD N/A
<LLD N/A Co-57 5.25E-04 0.013
<LLD N/A
<LLD N/A Totals 4.19 100.0 4.11 E+01 100.1 2.07E+04 100.0
- Activity is estimated 19
Revised 2008 Annual Radioactive Effluent Release Report Category B - Dry Compressible Waste, Contaminated Equipment, etc.
Waste Class A Percent Isotope Curies
- Abundance Fe-55 9.03E-02 46.53 Co-60 4.34E-02 22.36 Mn-54 2.62E-02 13.50 Cs-137 1.89E-02 9.74 Zn-65 1.25E-02 6.44 Ni-63 8.05E-04 0.41 Co-58 6.22E-04 0.32 Ag-110m 6.04E-04 0.31 Cs-134 2.08E-04 0.11 Ce-144 1.58E-04 0.08 Other 3.83E-04 0.20 Totals 1.94E-01 100.0
- Activity is estimated Category C - Irradiated components, control rods, etc.
Waste Class C Percent Isotope Curies
- Abundance Co-60 1.OOE+04 4.83E+01 Fe-55 9.48E+03 4.58E+01 Ni-63 9.43E+02 4.56E+00 Mn-54 2.62E+02 1.27E+00 Ni-59 4.86E+00 2.35E-02 C-14 1.46E+00 7.06E-03 Co-58 1.46E+00 7.06E-03 H-3 7.OOE-01 3.38E-03 Nb-94 2.04E-02 9.86E-05 Cs-137 1.89E-02 9.13E-05 Tc-99 1.06E-02 5.12E-05 Ce-144 1.58E-04 7.64E-07 Sr-90 5.91 E-05 2.86E-07 Pu-241 3.52E-05 1.70E-07 Am-241 1.04E-06 5.03E-09 Pu-238 9.39E-07 4.54E-09 Cm-243 7.55E-07 3.65E-09 Cm-242 5.71 E-07 2.76E-09 Pu-239 3.12E-07 1.51E-09 Totals 2.07E+04 100.0
- Activity is estimated 20
Revised 2008 Annual Radioactive Effluent Release Report
- 3.
Solid Waste (Disposition)
Number of Shipments Mode of Transportation Destination 8
Hitman Transport Co.
Barnwell Waste Management 7
Hitman Transport Co.
Duratek 3
Hitman Transport Co.
Duratek Radwaste Processing, Inc.
B. Irradiated Fuel Shipments (disposition). There were no irradiated fuel shipments.
21
Revised 2008 Annual Radioactive Effluent Release Report Appendix C Radiological Impact to Man 22
Revised 2008 Annual Radioactive Effluent Release Report Per ODCM Administrative Control 6.2, an assessment of radiation doses to the likely most exposed MEMBER OF THE PUBLIC from reactor releases and other nearby uranium fuel cycle sources (including doses from primary effluent pathways and direct radiation) for the previous calendar year must be made to show conformance with 40 CFR Part 190, Environmental Radiation Protection Standards for Nuclear Power Operation. For purposes of this calculation the following assumptions were made:
Gaseous Nearest resident was SE sector at 925 meters Actual meteorology and actual gaseous effluent releases were used.
All significant pathways were assumed to be present Occupancy factor was considered 100%.
Liquid There was no dose due to liquid releases.
A summary of gaseous and liquid radiation doses to most likely exposed MEMBER OF THE PUBLIC was as follows:
Applicable Estimated Age Location
% of EffAluent Organ Ese Ge Distance Direction Applicable Limit Unit Organ Dose Group (meters)
(toward)
Limit Noble Gas Gamma -
3.66E-03 All 405 E
3.66E-02 10 mrad Air Dose Noble Gas Beta - Air 4.63E-03 All 405 E
2.32E-02 20 mrad Dose Noble Gas Total Body 4.22E-04 All 925 SE 8.44E-03 5
mrem (Gamma)
Noble Gas Skin (Beta) 1.06E-03 All 925 SE 7.07E-3 15 mrem
& Tritium Liquid Total body 0
N/A N/A 0
3 mrem Liquid Organ 0
N/A N/A 0
10 mrem Direct Diat Total Body
<1 All 925 SE
< 4 25 mrem Radiation Doses calculated were well below all ODCM and 40 CFR Part 190 limits of 75 mrem to the thyroid and 25 mrem to the total body and any other organ. The 40 CFR Part 190 limits for Kr-85, 1-129, Pu-239 and other alpha-emitting transuranic radionuclides with half-lives greater than one year were not exceeded.
The ODCM does not require population doses to be calculated.
There are no radiological environmental sample parameters or locations where it is not possible or practical to obtain samples.
New Jersey State Police were not present full time at the plant entrance.
23
Revised 2008 Annual Radioactive Effluent Release Report Appendix D Meteorological Data Provided in original Submittal 24