Annual Radioactive Effluent Release Report 2009 Oyster Creek Nuclear Generating Station
Oyster Creek 2009 Annual Radioactive Effluent Release Report ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT January 1, 2009 through December 31, 2009 EXELON GENERATION COMPANY, LLC OYSTER CREEK NUCLEAR GENERATING STATION DOCKET NO. 50-219 (Oyster Creek Nuclear Generating Station)
DOCKET NO. 72-15 (Independent Spent Fuel Storage Facility)
Submitted to The United States Nuclear Regulatory Commission Pursuant to Renewed Facility Operating License DPR-16
Oyster Creek 2009 Annual Radioactive Effluent Release Report TABLE OF CONTENTS SECTION PAGE EXECUTIVE
SUMMARY
1
- 1. Introduction 3
- 2. Supplemental Information 3
A Regulatory Limits 3
B Effluent Concentration Limits 4
C Average Energy 4
D Measurements and Approximations of Total Radioactivity 4
E Batch Releases 5
F Average Stream Flow 5
G Abnormal Releases 6
H Revisions to the ODCM 6
I Radiation Effluent Monitors Out of Service More Than 30 Days 7
J Changes to the Process Control Plan 7
K Releases from the Independent Spent Fuel Storage Facility 7
L ERRATA 7
Appendix A - Effluent and Waste Disposal Summary 9
Appendix B - Solid Waste and Irradiated Fuel Shipments 15 Appendix C - Radiological Impact to Man 21 Appendix D - Meteorological Data 25 Appendix E - ODCM Revisions 83 Appendix F-ERRATA 85 ii
Oyster Creek 2009 Annual Radioactive Effluent Release Report (Page Intentionally Left Blank) iii
Oyster Creek 2009 Annual Radioactive Effluent Release Report EXECUTIVE
SUMMARY
Effluents are strictly monitored to ensure that radioactivity released to the environment is as low as reasonably achievable and does not exceed regulatory limits. Effluent control includes the operation of monitoring systems, in-plant and environmental sampling and analyses programs, quality assurance programs for effluent and environmental programs, and procedures covering all aspects of effluent and environmental monitoring.
Both radiological environmental and effluent monitoring indicate that the operation of Oyster Creek Nuclear Generating Station (OCNGS) does not result in significant radiation exposure of people or the environment surrounding OCNGS and is well below the applicable levels set by the Nuclear Regulatory Commission (NRC) and the Environmental Protection Agency (EPA).
There were no planned liquid radioactive effluent releases above ODCM Lower Limit of Detection (LLD) during 2009.
There were three abnormal liquid releases during 2009 resulting in an estimated total exposure of < 0.001 mRem to the most limiting member of the public.
On February 9, 2009 less than 1 gallon of condensation from the B Isocondenser vent leaked onto the ground. The tritium in the condensed water was 2.19E+04 pCi/I. The contaminated soil was placed in drums for disposal. No doses were calculated since the spill was contained and soil disposed.
On April 15, 2009, in preparation for work inside the Emergency Service Water (ESW) vault, water was found inside the vault. As part of standard practices for water removal, the water was pumped into drums and sampled for gamma emitters, tritium, and pH. Samples indicated elevated levels of tritium and a leak was subsequently confirmed by a monitoring well in the area. The release of tritiated water was caused by small leaks in 8-inch and 10-inch carbon steel Condensate System lines.
On August 24, 2009 a leak was discovered inside the turbine building coming from the turbine building west wall penetration housing a six-inch Condensate Transfer line. The leakage was found coming from the six-inch pipe within the wall penetration. After excavation of the pipe penetration from outside the turbine building, water was observed leaking from the pipe penetration into the excavation pit. The puddled water was pumped into drums for subsequent disposal.
The maximum hypothetical calculated organ dose (GI-LLI) from iodines, tritium and particulates to any individual due to gaseous effluents was 6.56E-3 mrem, which was approximately 4.37E-02 percent of the annual limit. The maximum calculated gamma air dose in the UNRESTRICTED AREA due to noble gas effluents was 1.61 E-04 mrem, which was 1.61 E-03 percent of the annual limit.
For comparison, the background radiation dose averages approximately 300 mRem per year in the Central New Jersey area, which includes approximately 200 mrem from naturally occurring radon gas and100 mrem from background radiation.
The Independent Spent Fuel Storage Installation (ISFSI) is a closed system and the only 1
Oyster Creek 2009 Annual Radioactive Effluent Release Report exposure would be due to direct radiation. This includes iodines, particulates and noble gases.
Based on offsite TLD readings, dose due to direct radiation from the ISFSI was less than 1 mRem for 2009. Because it is a sealed unit, no radioactive material was released.
Additionally, comparison of environmental sampling results to iodine and particulate gaseous effluents released, showed no radioactivity attributable to the operation of OCNGS.
Both elevated and ground-level release paths were considered in this review, with total iodines released of 6.02E-04 Ci and total particulates with half-lives greater than 8 days released of 1.78E-04 Ci.
Joint Frequency Tables of meteorological data, per Pasquill Category, as well as for all stability classes, are included. All data was collected from the on-site Meteorological Facility. Data recoveries for the 380-foot data and the 33-foot data were 97.8 percent and 97.8 percent, respectively. The UFSAR commits to Regulatory Guide (RG) 1.23 for Meteorological Facility data recovery. RG 1.23 requires data recovery of at least 90% on an annual basis.
2
Oyster Creek 2009 Annual Radioactive Effluent Release Report
- 1.
Introduction In accordance with the reporting requirements of Technical Specification 3.6.E.1 applicable during the reporting period, this report summarizes the effluent release data for Oyster Creek Generating Station for the period January 1, 2009 through December 31, 2009. This submittal complies with the format described in Regulatory Guide 1.21, "Measuring, Evaluating and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water Cooled Nuclear Power Plants", Revision 1, June, 1974.
Meteorological data was reported in the format specified in Regulatory Guide 1.23, Revision 1, "Meteorological Monitoring Programs for Nuclear Power Plants".
All vendor results were received and included in the report calculations. Therefore the 2009 report is complete.
- 2.
Supplemental Information A.
Regulatory Limits:
Limit Units Receptor ODCM and 10 CFR 50, Appendix I Desian Obiective Limits
- 1. Noble Gases:
- a.
< 500
< 3000
- b.
<_5
<10
- c.
<10
< 20
- d.
<5
<15 mrem/yr mrem/yr mrad mrad mrad mrad Total Body Skin Air Gamma Air Beta Air Gamma Air Beta Total Body (Gamma)
Skin (Beta) mrem mrem
- 2. lodines, Tritium, Particulates with Half Life > 8 days:
- a.
< 1500 mrem/yr Any Organ ODCM Control 3.11.2:1 Quarterly air dose limits ODCM Control 3.11.2.2 Yearly air dose limits ODCM Control 3.11.2.2 10 CFR 50, Appendix I, Section II.B.2(b)
ODCM Control 3.11.2.1 Quarterly dose limits ODCM Control 3.11.2.3 Yearly dose limits ODCM Control 3.11.2.3 ODCM Control 3.11.1.1 Quarterly dose limits ODCM Control 3.11.1.2 Yearly dose limits ODCM Control 3.11.1.2
- b.
<7.5
- c.
<15 mrem mrem Any Organ Any Organ
- 3. Liquid Effluents
- a.
Concentration 10 CFR 20, Appendix B, Table 2 Column 2
- b.
< 1.5
<5
- c.
<-3
<_10 mrem mrem mrem mrem Total Body Any Organ Total Body Any Organ 3
Oyster Creek 2009 Annual Radioactive Effluent Release Report B.
Effluent Concentration Limits:
Gaseous dose rates rather than effluent concentrations are used to calculate permissible release rates for gaseous releases. The maximum permissible dose rates for gaseous releases are defined in ODCM Controls 3.11.2.1.
The Effluent Concentration Limit (ECL) specified in 10 CFR 20, Appendix B, Table 2, Column 2 for identified nuclides, were used to calculate permissible release rates and concentrations for liquid release per ODCM Controls 3.11.1.1. The total activity concentration at the Route 9 bridge for all dissolved or entrained gases was limited to
< 2E-04 gCi/mL.
C. Average Energy ()
The Oyster Creek ODCM limits the instantaneous dose equivalent rates due to the release of noble gases to less than or equal to 500 mrem/year to the total body and less than or equal to 3000 mrem/year to the skin. The average beta and gamma energies (T) of the radionuclide mixture in releases of fission and activation gases as described in Regulatory Guide 1.21, "Measuring, Evaluation, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants," may be used to calculate doses in lieu of more sophisticated software. The Oyster Creek radioactive effluent program employs the methodologies presented in U.S. NRC Regulatory Guide 1.109 "Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR Part 50, Appendix I," Revision 1, October 1977 and NUREG-0133, "Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants, October 1978.
Therefore, average energy (*) as described in Regulstory Guide 1.21 is not applicable to Oyster Creek.
D. Measurements and Approximations of Total Radioactivity:
- 1.
Fission and Activation Gases The method used for Gamma Isotopic Analysis is the Canberra Gamma Spectroscopy System with a gas Marinelli beaker. Airborne effluent gaseous activity was continuously monitored and recorded in accordance with ODCM Table 4.11.2.1.2-1. Additional grab samples were taken from the stack RAGEMS sample point and ground-level release sample points and analyzed at least monthly to determine the isotopic mixture of noble gas activity released for the month. The data from the noble gas radiation monitor were analyzed to report net noble gas effluent activity. If activity was found in the grab isotopic analysis, the isotopic mixture for the Noble Gas Monitor was determined from that isotopic mixture. If no activity is detected in the grab samples, Xe-135 is assumed to be the nuclide detected by the noble gas radiation monitor. Cross-check samples for the gas Marinelli were not performed in 2009. There were numerous non-gas cross-check samples that were performed in 2009. These cross-check samples gave assurance that the efficiency of the detectors had not changed.
- 2.
Particulates and lodines The method used for Gamma Isotopic Analysis is the Canberra Gamma Spectroscopy System with a particulate filter (47 mm) and charcoal cartridge, respectively. Particulate and iodine activity was continuously sampled and analyzed in accordance with ODCM Table 4.11.2.1.2-1. Charcoal and particulate samples are taken from the stack RAGEMS sample point and ground-level release sample points and analyzed at least weekly to determine the total activity released from the plant based on the average vent flow rates recorded for the sampling period.
4
Oyster Creek 2009 Annual Radioactive Effluent Release Report
- 3.
Liquid Effluents During 2009, there were no planned radiological liquid releases. Since there were no liquid discharges in 2009, there was no dose attributable to liquid effluents.
- 4.
Tritium in Gaseous Effluents:
Air from stack effluents was passed through a desiccant column and distilled to remove the tritiated water collected. An aliquot of the water from the distillate was analyzed using a liquid scintillation counter.
- 5.
Composite Samples and Lower Limit of Detection (LLD)
Particulate air samples were composited monthly and analyzed for gross alpha, Sr-89 and Sr-90. These composites are submitted to an offsite vendor laboratory for analysis. The ODCM required lower limit of detection for liquid and airborne releases are as follows:
Liquid:
LLD Principal Gamma Emitters (Mn-54, Fe-59, Co-58, Co-60, Zn-65, 1-131, Ce-141, Cs-134, Cs-137) 5E-07 pCi/ml Principal Gamma Emitters (Mo-99, Ce-144) 1E-05 pCi/mI Dissolved and Entrained Gases 1 E-05 pCi/ml H-3 1 E-05 pCi/ml Gross Alpha 1 E-07 pCi/ml Sr-89, Sr-90 5E-08 pCi/ml Fe-55 1 E-06 pCi/mI Airborne LLD Principal Gamma Emitters (Kr-87, Kr-88, Xe-133, Xe-133m, Xe-135, Xe-138) 1E-04 pCi/ml H-3 1 E-06 pCi/ml 1-131 1 E-12 pCi/ml 1-133 1E-1O0 pCi/ml Principal Gamma Emitters (Mn-54, Fe-59, Co-58, Co-60, Zn-65, Mo-99, Cs-134, Cs-137, Ce-141, Ce-144) 1E-11 pCi/mI Gross Alpha 1E-11 pCi/ml Sr-89, Sr-90 1E-11 pCi/ml
- 6.
Estimated Total Error Present Procedure CY-AA-170-2100, Estimated Errors of Effluent Measurements, provides the methodology to obtain an overall estimate of the error associated with radioactive effluents.
E.
Batch Releases:
There were no batch releases of liquid or gaseous effluents during 2009.
F.
Average Stream Flow:
5
Oyster Creek 2009 Annual Radioactive Effluent Release Report There were no planned releases of liquid effluent in 2009. See the abnormal releases section for discharge canal flows used for calculations.
G. Abnormal Releases:
There were three abnormal liquid releases during 2009.
- 1.
On February 9, 2009 less than 1 gallon of condensation from the B Isocondenser vent leaked onto the ground. The tritium in the condensed water was 2.19E+04 pCi/I (8.29E-08 Ci). The contaminated soil was placed in drums for disposal. No doses were calculated since the spill was contained and soil disposed.
- 2.
On April 15, 2009, in preparation for work inside the Emergency Service Water (ESW) vault, water was found inside the vault. As part of standard practices for water removal, the water was pumped into drums and sampled for gamma emitters, tritium, and pH. Sample analysis identified tritium levels at 102,000 pCi/I. Investigation determined that the release of tritiated water was caused by leaks in the 8-inch and 10-inch carbon steel Condensate System lines. The root cause investigation determined that the piping leaks developed due to a corrosion mechanism known as anodic dissolution. Poor application of pipe coating left the buried pipes susceptible to this corrosion.
A bounding calculation of the doses was done. A total of 66 Ci of tritium was assumed to be released to the discharge canal over a 4 month period with a dilution flow of 500,000 gpm. The total body and organ doses were both 6.06E-04 mrem. Dose from this release is not included in the Liquid Effluents -
Summary of all Releases.
- 3.
On August 24, 2009 an eight to ten gallon per minute leak was discovered in the condenser bay. The leak was coming from the turbine building west wall penetration housing the Condensate Transfer CH-5 line, the six-inch Condensate Transfer Main Header. Two leaks were found in the pipe within the wall penetration. A tritium concentration of 1.08E+07 pCi/I was detected. The root cause investigation determined the cause to be galvanic corrosion.
A bounding calculation of the doses was done. A total of 2.06 Ci of tritium was assumed to be released to the discharge canal over a 7 day period with a dilution flow of 1 E+06 gpm. The total body and organ doses were both 9.36E-06mrem. Dose from this release is no included in the Liquid Effluents -
Summary of all Releases.
H. Revisions to the ODCM:
Revision 3 of CY-OC-170-301, Offsite Dose Calculation Manual was approved during April, 2009. A complete copy, along with detailed information justifying the changes, a determination that the changes did not reduce the accuracy or reliability of dose calculations or setpoint determination, and documentation of review and approval is in Appendix E.
The following is a summary of the changes made in Revision 3.
" Changes to REMP sample locations.
" Change the reporting level of 1-131 to 2 pCi/L
" Update X/Q and D/Q factors to average values from the last five years of met data.
" Use of the updated X/Q and D/Q factors in example dose calculations.
" Add a reference for a report from a vendor's hydrogeologic investigation report.
" A complete re-write of Table E-1 describing REMP sample stations.
" Updated maps of the 1-mile, 1 to 5-mile and greater than 5-mile rings showing REMP sample stations.
6
Oyster Creek 2009 Annual Radioactive Effluent Release Report Revision 4 of CY-OC-1 70-301, Offsite Dose Calculation Manual, was approved during September 2009. A complete copy, along with detailed information justifying the changes, a determination that the changes did not reduce the accuracy or reliability of dose calculations or setpoint determination, and documentation of review and approval is in Appendix E.
The following is a summary of the changes made in Revision 4.
" Administrative changes
" Added projected dose requirements for liquid and gas effluents
" Provided justification for liquid composite sampling methods
" Provided justification for gaseous tritium sampling quarterly
" Added limits for operation of the liquid and gas treatment systems
- 1. Radiation Effluent Monitors Out of Service More Than 30 Days Per ODCM Control 3.11, "Radioactive Liquid Effluent Monitoring Instrumentation" and Table 3.3.3.11-1 Radioactive Gaseous Effluent Monitoring Instrumentation", instrumentation requires:
With less than the minimum number of radioactive gaseous effluent monitoring instrumentation channels OPERABLE, take the ACTION shown in Table 3.3.3.11-1. Restore the inoperable instrumentation to OPERABLE status within the time specified in the ACTION or explain in the next Annual Radioactive Effluent Release Report why this inoperability was not corrected within the time specified.
The following is a discussion of instrumentation out of service for greater than 30 days:
The Service Water radiation monitor was out of service from 09/25/2008 to 11/06/2009 due to inoperable instrumentation. An investigation revealed that the monitor could not be repaired and that new components had to be manufactured.
J.
Revisions to the Process Control Plan:
There were no changes to the Process Control Plan in 2009.
K. Releases from the Independent Spent Fuel Storage Facility:
The Independent Spent Fuel Storage Installation (ISFSI) is a closed system and the only exposure would be due to direct radiation. This includes iodines, particulates, and noble gases. Based on offsite TLD readings, dose due to direct radiation from the ISFSI was less than 1 mRem for 2009. Because it is a sealed unit, no radioactive material was released L. Errata:
Revisions 6 and 7 of the Process Control Plan (PCP) (RW-AA-100) were approved June 2008 and December 2008 respectively. As required by Technical Specifications, complete copies of the procedures, along with a summary of changes are included in Appendix F.
The 2008 Annual Radioactive Effluent Release Report (ARERR) had errors. A revised 2008 ARERR is included in Appendix F.
7
Oyster Creek 2009 Annual Radioactive Effluent Release Report (Page Intentionally Left Blank) 8
Oyster Creek 2009 Annual Radioactive Effluent Release Report Appendix A Effluent and Waste Disposal Summary 9
Oyster Creek 2009 Annual Radioactive Effluent Release Report LIST OF TABLES PAGE Table A - 1 Gaseous Effluents - Summation of All Releases 11 Table A - 2 Gaseous Effluents for Release Point - Elevated 12 Table A - 3 Gaseous Effluents for Release Point - Ground Level 13 Table A - 4 Liquid Effluents - Summation of All Releases 14 10
Oyster Creek 2009 Annual Radioactive Effluent Release Report TABLE A -1 GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES A.
FISSION AND ACTIVATION GASES PERIOD 2009 Units Qtr 1 Qtr 2 Qtr 3 Qtr 4 Est. Total Error %
- 1. Total Release Ci 1.29E-07 6.48E-01 7.85E+00 6.86E+00 25
- 2. Averaae Release Rate for Period uCi/sec 1.66E-08 8.24E-02 9.88E-01 8.63E-01
- 3. Dose m rad
,1.17E-09 1.95E-05 9.58E-05 1.24E-04
-Gamma Air Dose
- Beta Air Dose mrad 1.50E-09 1.26E-05 6.76E-05 4.79E-05
- 4. Percent of ODCM Limit 2.34E-08 3.90E-04 1.92E-03 2.48E-03
- Gamma Air Dose
- Beta Air Dose 1.50E-08 I 1.26E-04 6.76E-04 4.79E-04 B.
IODINES Est. Total Units Qtr 1 Qtr 2 Qtr 3 Qtr 4 Erroral Error %
- 1. Total 131 Ci 2.73E-05 1.07E-04 2.23E-05 4.78E-06 25
- 2. Average Release Rate for Period pCi/sec 3.51 E-06 1.36E-05 2.80E-06 6.01 E-07
- 3. Percent of ODCM limit C.
PARTICULATES Est. Total Units Qtr 1 Qtr 2 Qtr 3 Qtr 4 Erroral Error %
- 1. Particulates with T 1/2 > 8 days Ci 1.71 E-05 1.22E-05 1.36E-04 1.27E-05 25
- 2. Average Release Rate for Period pCi/sec 2.20E-06 1.55E-06 1.71 E-05 1.60E-06
- 3. Percent of ODCM limit
- 4. Gross Alpha Radioactivity Ci
<LLD
<LLD I
<LLD
<LLD D.
TRITIUM Units Qtr 1 Qtr 2 Qtr 3 Qtr 4 Est. Total I
_Error
- 1. Total Release Ci 1.45E+00 2.97E+00 5.70E-01 4.87E-01 25
- 2. Average Release Rate for Period pCi/sec 1.87E-01 3.79E-01 7.17E-02 6.13E-02
[3. Percent of ODCM limit
[%
I E.
Iodine 131 & 133, Tritium & Particulate Units Qtr 1 Qtr 2 Qtr 3 Qtr 4
- 1. Organ Dose mrem 3.70E-04 8.63E-04 5.76E-03 4.54E-04
- 2. Percent of ODCM Limit 4.93E-03 1.15E-02 7.68E-02 6.05E-03
11
Oyster Creek 2009 Annual Radioactive Effluent Release Report TABLE A-2 GASEOUS EFFLUENTS FOR RELEASE POINT -
ELEVATED PERIOD 2009
- 1.
FISSION AND ACTIVATION GASES Nuclide Released Continuous Mode Units Qtr 1 Qtr 2 Qtr 3 Qtr 4 KR-85 Ci
<LLD
<LLD
<LLD
<LLD KR-85M Ci
<LLD
<LLD
<LLD
<LLD KR-87 Ci
<LLD
<LLD
<LLD
<LLD KR-88 Ci
<LLD
<LLD
<LLD
<LLD XE-131M Ci
<LLD
<LLD
<LLD
<LLD XE-1 33 Ci
<LLD
<LLD
<LLD
<LLD XE-1 33M Ci
<LLD
<LLD
<LLD
<LLD XE-1 35 Ci
<LLD 6.48E-01 7.85E+00 6.86E+00 XE-1 35M Ci
<LLD
<LLD
<LLD
<LLD XE-1 38 Ci
<LLD
<LLD
<LLD
<LLD KR-85 Ci
<LLD
<LLD
<LLD
<LLD Total for Period Ci
<LLD 6.48E-01 7.85E+00 6.86E+00
- 2.
IODINES Nuclide Released Continuous Mode Units Qtr 1 Qtr 2 Qtr 3 Qtr 4 1-131 Ci 2.73E-05 1.07E-04 2.23E-05 4.72E-06 1-133 Ci 2.96E-05 4.12E-04
<LLD
<LLD Total for Period Ci 5.69E-05 5.19E-04 2.23E-05 4.72E-06
- 3.
PARTICULATES (T 1/2 > 8 DAYS)
Nuclide Released Continuous Mode Units Qtr 1 Qtr 2 Qtr 3 Qtr 4 MN-54 Ci 6.83E-06 1.22E-05
<LLD
<LLD FE-59 Ci
<LLD
<LLD
<LLD
<LLD CO-58 Ci
<LLD
<LLD
<LLD
<LLD CO-60 Ci
<LLD
<LLD
<LLD
<LLD ZN-65 Ci
<LLD
<LLD
<LLD
<LLD SR-89 Ci 1.03E-05
<LLD
<LLD
<LLD SR-90 Ci
<LLD
<LLD
<LLD
<LLD ZR-95 Ci
<LLD
<LLD
<LLD
<LLD NB-95 Ci
<LLD
<LLD
<LLD
<LLD MO-99 Ci
<LLD
<LLD
<LLD
<LLD CS-1 34 Ci
<LLD
<LLD
<LLD
<LLD CS-137 Ci
<LLD
<LLD
<LLD
<LLD CE-141 Ci
<LLD
<LLD
<LLD
<LLD CE-144 Ci
<LLD
<LLD
<LLD
<LLD BA-140 Ci
<LLD
<LLD
<LLD
<LLD Total for Period Ci 1.71 E-05 1.22E-05
<LLD
<LLD 12
Oyster Creek 2009 Annual Radioactive Effluent Release Report TABLE A-3 GASEOUS EFFLUENTS FOR RELEASE POINT -
GROUND LEVEL
- 1.
FISSION AND ACTIVATION GASES PERIOD 2009 Nuclide Released Continuous Mode Units Qtr 1 Qtr 2 Qtr 3 Qtr 4 AR-41 Ci
<LLD
<LLD
<LLD
<LLD KR-85M Ci
<LLD
<LLD
<LLD
<LLD KR-87 Ci
<LLD
<LLD
<LLD
<LLD KR-88 Ci
<LLD
<LLD
<LLD
<LLD XE-133 Ci
<LLD
<LLD
<LLD
<LLD XE-1 33M Ci
<LLD
<LLD
<LLD
<LLD XE-135 Ci 1.29E-07
<LLD
<LLD
<LLD XE-1 35M Ci
<LLD
<LLD
<LLD
<LLD XE-1 38 Ci
<LLD
<LLD
<LLD
<LLD KR-85 Ci
<LLD
<LLD
<LLD
<LLD Total for Period Ci 1.29E-07
<LLD
<LLD
<LLD
- 2.
IODINES Nuclide Released Continuous Mode Units Qtr 1 Qtr 2 Qtr 3 Qtr 4 1-131 Ci
<LLD
<LLD
<LLD 5.78E-08 1-133 Ci 1.12E-07
<LLD
<LLD 9.63E-08 Total for Period Ci 1.12E-07
<LLD
<LLD 1.54E-07
- 3.
PARTICULATES (T 1/2 > 8 DAYS)
Nuclide Released Continuous Mode Units Qtr I Qtr 2 Qtr 3 Qtr 4 MN-54 Ci
<LLD
<LLD 1.31 E-05 8.71 E-06 FE-59 Ci
<LLD
<LLD
<LLD
<LLD CO-58 Ci
<LLD
<LLD
<LLD
<LLD CO-60 Ci
<LLD
<LLD 1.23E-04 4.OOE-06 ZN-65 Ci
<LLD
<LLD
<LLD
<LLD SR-89 Ci
<LLD
<LLD
<LLD
<LLD SR-90 Ci
<LLD
<LLD
<LLD
<LLD ZR-95 Ci
<LLD
<LLD
<LLD
<LLD NB-95 Ci
<LLD
<LLD
<LLD
<LLD MO-99 Ci
<LLD
<LLD
<LLD
<LLD CS-1 34 Ci
<LLD
<LLD
<LLD
<LLD CS-1 37 Ci
<LLD
<LLD
<LLD
<LLD CE-141 Ci
<LLD
<LLD
<LLD
<LLD CE-144 Ci
<LLD
<LLD
<LLD
<LLD Total for Period Ci
<LLD
<LLD 1.36E-04 1.27E-05 13
Oyster Creek 2009 Annual Radioactive Effluent Release Report TABLE A - 4 LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES PERIOD 2009 A.
FISSION AND ACTIVATION PRODUCTS Est. Total Units Qtr 1 Qtr 2 Qtr 3 Qtr 4 Erroral Error %
- 1. Total release (not including tritium, Ci
<LLD
<LLD
<LLD
<LLD N/A gasses & alpha)
- 2. Average diluted concentration during uCi/mI
<LLD
<LLD
<LLD
<LLD batch discharge for the period
- 3. Dose
- Whole Body mrem N/A N/A N/A N/A
- Organ mrem N/A N/A N/A N/A
- 4. % of ODCM Limit - Whole Body Dose*
N/A N/A N/A N/A
- Organ Dose*
N/A N/A N/A N/A B. TRITIUM I
Est. Total Units Qtr 1 Qtr 2 Qtr 3 Qtr 4 Erroral Error %
- 1. Total Release (Abnormal Releases)
Ci 8.29E-08 6.60E+01 2.06 N/A N/A
- 2. Average diluted concentration during uCi/mI N/A 3.84E-07 4.72E-08 N/A batch discharge for the period
%3.
of ODCM Limit - ECL N/A 3.84E-02 4.72E-03 N/A C. DISSOLVED AND ENTRAINED GASSES Est. Total Units Qtr 1 Qtr 2 Qtr 3 Qtr 4 Erroral Error %
- 1. Total release Ci
<LLD
<LLD
<LLD
<LLD N/A
- 2. Average diluted concentration during uCi/mI N/A N/A N/A N/A batch discharge for the period 3._%of ODCM Limit - ECL N/A N/A N/A N/A D. GROSS ALPHA RADIOACTIVITY T
Est. Total Units Qtr 1 Qtr 2 Qtr 3 Qtr 4 Erroral Error %
- 1. Total release Ci
<LLD
<LLD
<LLD
<LLD N/A
- 2. Average diluted concentration during uCi/mI N/A N/A N/A N/A batch discharge for the period Est. Total Units Qtr 1 Qtr 2 Qtr 3 Qtr 4 Error %
E. Volume of waste released (prior to dilution)
Liters N/A N/A N/A N/A N/A F.
Volume of dilution water used during Liters N/A N/A N/A N/A N/A period Percent of limit does not include abnormal releases 14
Oyster Creek 2009 Annual Radioactive Effluent Release Report Appendix B Solid Waste and Irradiated Fuel Shipments Solid waste shipped offsite for burial or disposal (not irradiated fuel) 1/1/09 - 12/31/09 15
Oyster Creek 2009 Annual Radioactive Effluent Release Report LIST OF TABLES PAGE Table 1. Types of Waste 17 Table 2. Estimate of Major Nuclide Composition (By Waste Type) 18 Table 3. Solid Wate (Disposition) 20 16
Oyster Creek 2009 Annual Radioactive Effluent Release Report
- 1. Type of waste Type of waste Unit 12 Month Period Estimated Error %
- a. Spent resin, filters sludges, evaporator bottoms, etc m3 5.13E+01 25%
Ci 5.21 E+01
- b. Dry compressible waste, contaminated equipment, etc. m3 3.28E+02 25%
Ci 6.01 E02
- c. Irradiated components, control rods, etc.
mC 0.OOE+00 25%
Ci 1.OOE+00 Ohr-Scrap Metal Im3 1 1.42E+02 1
25%
1Ci I2.80E-01 I
17
Oyster Creek 2009 Annual Radioactive Effluent Release Report
- 2.
Estimate of Major Nuclide Composition (By Waste Type)
Category A - Spent Resin, Filters, Sludges, Evaporator Bottoms, etc.
Waste Class Percent Waste Class Percent Isotope A
B Curiepe Abundance C
Abundance Curies*
Curies*
H-3 3.45E-02 0.143%
2.72E-02 0.097%
C-14 2.88E-01 1.195%
5.81E-01 2.081%
Mn-54 1.40E+00 5.820%
5.51 E-01 1.975%
Fe-55 7.30E+00 30.237%
5.62E+00 20.128%
Fe-59 4.47E-08 0.000%
Co-57 6.61 E-03 0.027%
Co-58 5.OOE-04 0.002%
1.08E-05 0.000%
Co-60 9.76E+00 40.445%
9.57E+00 34.273%
Ni-63 1.34E-01 0.556%
2.44E-01 0.875%
Zn-65 5.17E-01 2.142%
2.18E-01 0.781%
Sr-89 3.34E-06 0.000%
Sr-90 1.23E-02 0.051%
3.38E-02 0.121%
Zr-95 1.06E-06 0.000%
Nb-95 4.54E-09 0.000%
Tc-99 7.49E-03 0.031%
Ag-11im 3.17E-02 0.131%
4.63E-03 0.017%
Sb-125 1.89E-03 0.008%
Cs-134 3.1OE-02 0.129%
7.91 E-02 0.283%
Cs-1 37 4.57E+00 18.927%
1.10E+01 39.267%
Ce-144 2.70E-02 0.112%
6.34E-03 0.023%
Pu-238 2.58E-04 0.001%
3.15E-04 0.001%
Pu-239 1.01 E-04 0.000%
1.33E-04 0.000%
Pu-241 9.89E-03 0.041%
1.97E-02 0.071%
Am-241 2.80E-04 0.001%
1.04E-03 0.004%
Cm-242 6.97E-06 0.000%
Cm-243 1.47E-04 0.001%
5.01 E-04 0.002%
Totals 2.41 E+01 100.00%
2.80E+01 100.00%
- Activity is estimated 18
Oyster Creek 2009 Annual Radioactive Effluent Release Report Category B - Dry Compressible Waste, Contaminated Equipment, etc.
Waste Class Waste Class Percent Isotope A
Percent B
Abundance Curies*
Abundance Curies*
H-3 7.83E-02 1.823%
2.04E-02 0.003%
C-14 1.78E-01 4.135%
1.05E-01 0.018%
Mn-54 2.89E-01 6.736%
7.41 E+00 1.242%
Fe-55 1.68E+00 39.224%
5.05E+02 84.675%
Co-57 1.17E-05 0.000%
1.84E-03 0.000%
Co-58 4.71E-04 0.011%
6.OOE-04 0.000%
Co-60 1.55E+00 36.066%
4.93E+01 8.262%
Ni-63 3.30E-02 0.768%
2.39E+00 0.400%
Zn-65 9.86E-02 2.296%
1.52E+00 0.255%
Sr-89 2.45E-05 0.001%
5.97E-07 0.000%
Sr-90 2.49E-03 0.058%
1.77E-01 0.030%
Tc-99 2.23E-05 0.001%
4.34E-02 0.007%
Ag-110m 5.81E-03 0.135%
5.78E-02 0.010%
Sb-125 2.53E-03 0.059%
Cs-134 1.25E-04 0.003%
1.60E-01 0.027%
Cs-137 3.64E-01 8.468%
2.98E+01 4.988%
Ce-144 7.48E-03 0.174%
2.33E-01 0.039%
Pu-238 1.36E-05 0.000%
3.59E-03 0.001%
Pu-239 9.85E-06 0.000%
1.07E-03 0.000%
Pu-240 9.66E-06 0.000%
6.63E-04 0.000%
Pu-241 1.64E-03 0.038%
2.37E-01 0.040%
Am-241 6.85E-05 0.002%
8.06E-03 0.001%
Cm-242 1.19E-06 0.000%
4.66E-05 0.000%
Cm-243 2.69E-05 0.001%
7.33E-03 0.001%
Cm-244 2.62E-05 0.001%
6.1OE-03 0.001%
Totals 4.29E+00 100.00%
5.96E+02 100.00%
- Activity is estimated Category C - Irradiated components, control rods, etc.
No Irradiated components, control rods, etc. shipped 19
Oyster Creek 2009 Annual Radioactive Effluent Release Report Category D - Other - Scrap Metal Waste Class Percent Isotope A
Curies*
Abundance H-3 2.70E-01 96.430%
C-14 8.07E-06 0.003%
Mn-54 1.34E-03 0.477%
Fe-55 4.66E-03 1.664%
Co-57 8.92E-07 0.000%
Co-58 3.56E-05.
0.013%
Co-60 2.16E-03 0.770%
Ni-63 2.18E-04 0.078%
Zn-65 5.98E-04 0.214%
Sr-89 1.85E-06 0.001%
Sr-90 1.89E-06 0.001%
Tc-99 1.70E-06 0.001%
Ag-11Om 3.33E-05 0.012%
Cs-1 34 9.52E-06 0.003%
Cs-1 37 9.30E-04 0.332%
Ce-144 6.30E-06 0.002%
Pu-238 4.15E-08 0.000%
Pu-239 1.41 E-08 0.000%
Pu-241 1.64E-06 0.001%
Am-241 4.44E-08 0.000%
Cm-242 2.53E-08 0.000%
Cm-243 2.81 E-08 0.000%
Total 2.80E-01 100.00%
- Activity is estimated
- 3.
Solid Waste (Disposition)
Number of Shipments Mode of Transportation Destination 18 Hittman Transport Co.
Barnwell Disposal Facility 10 Hittman Transport Co.
Duratek 2
Hittman Transport Co.
Duratek Radwaste Processing, Inc.
B. Irradiated Fuel Shipments (disposition).
There were no irradiated fuel shipments 20
Oyster Creek 2009 Annual Radioactive Effluent Release Report Appendix C Radiological Impact to Man 21
Oyster Creek 2009 Annual Radioactive Effluent Release Report (Page Intentionally Left Blank) 22
Oyster Creek 2009 Annual Radioactive Effluent Release Report Per ODCM Administrative Control 6.2, an assessment of radiation doses to the likely most exposed MEMBER OF THE PUBLIC from reactor releases and other nearby uranium fuel cycle sources (including doses from primary effluent pathways and direct radiation) for the previous calendar year must be made to show conformance with 40 CFR Part 190, Environmental Radiation Protection Standards for Nuclear Power Operation. For purposes of this calculation the following assumptions were made:
Gaseous Nearest resident was SE sector at 925 meters Actual meteorology and actual gaseous effluent releases were used All significant pathways were assumed to be present Occupancy factor was considered 100%.
Liquid There was no dose due to planned liquid releases.
A summary of gaseous and liquid radiation doses to most likely exposed MEMBER OF THE PUBLIC was as follows:
Location
% of EfletApplicable Estimated Age Location
%O Effluent A
cabe Dstmed AGru Distance Direction Applicable Limit Unit Organ Dose Group (meters)
(toward)
Limit Noble Gas Gamma-1.61 E-04 All 540 SSE 1.61 E-03 10 mrad Air Dose Noble Gas Beta-Air 9.65E-05 All 500 E
4.83E-04 20 mrad Dose Noble Gas Total Body 6.72E-05 All 5635 SSW 1.34E-03 5
mrem (Gamma)
Noble Gas Skin (Beta) 1.03E-04 All 5635 SSW 6.87E-04 15 mrem
- Iodine, Particulate GI-LLI 6.56E-03 Teen 1169 ESE 4.37E-02 15 mrem
& Tritium II Liquid Total body
<LLD
<LLD 925 SE
<LLD 3
mrem Liquid Organ
<LLD
<LLD 925 SE
<LLD 10 mrem Direct Total Body
<1 All 925 SE
<4 25 mrem Radiation Doses calculated were well below all ODCM and 40 CFR Part 190 limits of 75 mrem to the thyroid and 25 mrem to the total body and any other organ. The 40 CFR Part 190 limits for Kr-85, 1-129, Pu-239 and other alpha-emitting transuranic radionuclides with half-lives greater than one year were not exceeded.
The ODCM does not require population doses to be calculated.
There are no radiological environmental sample parameters or locations where it is not possible or practical to obtain samples.
New Jersey State Police were not present full time at the plant entrance.
23
Oyster Creek 2009 Annual Radioactive Effluent Release Report (Page Intentionally Left Blank) 24
Oyster Creek 2009 Annual Radioactive Effluent Release Report Appendix D Meteorological Data 25
Oyster Creek 2009 Annual Radioactive Effluent Release Report LIST OF METEOROLOGICAL DATA TABLES PAGE Table D - 1 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, January - March, 2009 27 Table D - 2 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, January - March, 2009 34 Table D - 3 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, April - June, 2009 41 Table D - 4 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, April - June, 2009 48 Table D - 5 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, July - September, 2009 55 Table D - 6 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, July-September, 2009 62 Table D - 7 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, October - December, 2009 69 Table D - 8 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, October - December, 2009 76 26
Table D - 1 Oyster Creek 2009 Annual Radioactive Effluent Release Report Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, January - March, 2009 Oyster Creek Alpha Period of Record: January -
March, 2009 Stability Class A -
Extremely Unstable -
15OFt-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 0
0 1
0 0
0 0
0 0
0 0
0 0
0 1
0 0
8 5
7 10 11 14 3
1 3
2 4
3 10 13 15 4
0 8-12 13-18 19-24
> 24 3
0 0
0 4
0 0
0 5
0 0
0 14 0
0 0
6 0
0 0
5 0
0 0
9 0
0 0
7 0
0 0
12 5
2 0
7 0
1 0
4 0
0 0
12 1
0 0
12 6
0 0
51 20 0
0 49 24 2
0 39 1
0 0
0 0
0 0
Total 11 9
13 24 17 19 12 8
22 10 8
16 28 84 91 44 0
Total 2
113 239 57 5
0 416 Hours of calm in Hours of missing this stability class:
wind measurements in this 0
stability class:
3 all stability classes:
Hours of missing stability measurements in 14 27
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 1 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, January - March, 2009 Oyster Creek Alpha Period of Record: January - March, 2009 Stability Class B - Moderately Unstable
- 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
0 1
0 0
0 3
0 0
1 0
0 4-7 8-12 13-18 19-24
> 24 Total 0
0 0
0 0
0 0
0 0
0 0
0 0
3 3
7 4
3 1
8 2
8 4
2 5
WSW W
NW NNW Variable Total 1
0 1
1 0
1 9
8 10 2
6 2
0 3
0 4
0 7
0 1
0 0
1 0
12 0
26 0
10 0
0 8
42 38 16 0
105 Hours of Hours of Hours of calm in missing missing this stability class:
wind measurements in this stability measurements in 0
stability class:
all stability cl 0
asses:
14 28
Oyster Creek 2009 Annual Radioactive Effluent Release Report Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, January - March, 2009 Table D - 1 Oyster Creek Alpha Period of Record: January -
March, 2009 Class C -
Slightly Unstable 15OFt-33Ft Winds Measured at 33 Feet Stability Delta-T (F)
Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 0
0 0
0 0
1 1
0 0
0 1
0 0
0 2
0 0
2 2
2 1
1 0
0 0
0 0
0 2
2 1
1 3
0 8-12 13-18 19-24
> 24 0
0 0
0 2
0 0
0 2
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 2
1 0
0 3
0 0
0 2
0 0
0 0
0 0
0 0
1 0
0 1
1 0
0 5
1 0
0 3
1 0
0 0
0 0
0 Total 2
4 4
1 1
1 1
0 3
3 3
2 3
3 9
7 0
Total 5
17 20 5
0 0
47 Hours of calm in Hours of missing this stability class:
wind measurements in this 0
stability class:
0 all stability classes:
Hours of missing stability measurements in 14 29
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 1 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, January - March, 2009 Oyster Creek Alpha Period of Record: January -
- March, 2009 Class D -
Neutral 15OFt-33Ft Winds Measured at 33 Feet Stability Delta-T (F)
Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 Total 2
13 4
2 5
2 1
5 3
2 3
2 10 7
7 7
0 17 27 39 12 5
5 9
13 19 8
6 5
14 15 24 23 0
18 8
15 5
4 2
4 4
10 8
4 5
7 24 36 12 0
1 1
0 0
0 1
0 1
5 2
1 4
6 1
12 1
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 2
0 0
38 49 58 19 14 10 14 23 37 20 14 16 37 47 81 43 0
Total 75 241 166 36 2
0 520 Hours of calm in Hours of missing this stability class:
wind measurements in this 0
stability class:
2 all stability classes:
Hours of missing stability measurements in 14 30
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 1 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, January - March, 2009 Oyster Creek Alpha Period of Record: January -
- March, 2009 Class E - Slightly Stable 150Ft-33Ft Winds Measured at 33 Feet Stability Delta-T (F)
Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 Total 0
6 8
4 3
2 0
7 7
4 5
6 17 10 12 11 0
6 7
4 2
4 1
2 13 17 13 16 28 38 64 53 31 0
1 0
6 3
2 1
0 2
13 18 10 14 35 43 39 12 0
7 13 18 9
9 4
2 22 40 35 31 52 93 124 113 54 0
Total 102 299 199 25 1
0 626 Hours of calm in this stability class:
Hours of missing wind measurements in this Hours of missing stability measurements in 1
stability class:
0 all stability classes:
14 31
Oyster Creek 2009 Annual Radioactive Effluent Release Report Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, January - March, 2009 Table D - 1 Stability Wind Oyster Creek Alpha Period of Record: January -
- March, 2009 Class F - Moderately Stable 15OFt-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 6
1 0
0 1
0 0
0 4
0 0
0 0
0 0
0 0
0 0
0 0
1 0
0 0
1 0
0 5
3 0
0 2
8 0
0 7
2 0
0 4
10 0
0 3
16 0
0 18 25 0
0 15 16 0
0 18 23 1
0 10 7
0 0
0 0
0 0
19-24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
> 24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
Total 7
1 4
0 0
1 1
8 10 9
14 19 43 31 42 17 0
Total 93 113 I
0 0
0 207 Hours of calm in this stability class:
0 Hours of missing wind measurements in this stability class:
0 Hours of missing stability measurements in all stability classes:
14 32
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 1 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating.Station, January - March, 2009 Oyster Creek Alpha Period of Record: January - March, 2009 Stability Class G - Extremely Stable
- 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24
> 24 Total N
NNE NE ENE E
1 3
1 0
0 1
0 5
4 0
0 0
0 0
0 0
0 1
0 S
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 1
0 0
0 0
5 1
3 1
wNw NW 4
11 2
26 18 28 13 46 12 17 16 0
0 0
0 0
0 0
0 0
13 0
44 0
41 0
58 0
33 Variable Total 6
0 154 3
0 65 0
9 0
0 0
219 Hours of calm in Hours of missing Hours of missing this stability class:
wind measurements in this stability measurements in 0
stability class:
0 all stability classes:
14 33
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 2 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, January - March, 2009 Oyster Creek Alpha Period of Record: January - March, 2009 Stability Class A - Extremely Unstable
- 380Ft-33Ft Delta-T (F)
Winds Measured at 380 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
.0 0
0 0
0 0
0 8-12 13-18 19-24
> 24 0
2 1
0 0
0 0
0 2
1 0
0 1
2 0
0 5
0 0
0 2
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
1 0
0 0
0 0
.0 0
4 0
0 0
1 0
9 0
0 9
1 1
7 2
0 0
0 0
0 Total 3
0 3
3 5
2 0
0 0
0 1
0 4
10 10 10 0
Total 0
0 11 18 12 10 51 Hours of calm in this stability class:
0 Hours of missing wind measurements in this stability class:
0 Hours of missing stability measurements in all stability classes:
14 34
Table D - 2 Oyster Creek 2009 Annual Radioactive Effluent Release Report Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, January-March, 2009 Oyster Creek Alpha Period of Record: January - March, 2009 Stability Class B - Moderately Unstable
- 380Ft-33Ft Delta-T (F)
Winds Measured at 380 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 Total 0
0 0
0 0
0 0
0 0
2 0
0 2
1 4
0 1
1 3
5 3
5 3
0 0
7 1
1 7
13 21 8
0 Total 0
3 23 26 20 7
79 Hours of calm in this stability class:
0 Hours of missing Hours of missing wind measurements in this stability class:
0 stability measurements in all stability classes:
14 35
Oyster Creek 2009 Annual Radioactive Effluent Release Report Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, January - March, 2009 Table D - 2 Oyster Creek Alpha Period of Record: January -
March, 2009 Class C
- Slightly Unstable 380Ft-33Ft Winds Measured at 380 Feet Stability Delta-T (F)
Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 2
0 1
2 1
0 0
0 0
1 1
0 0
0 0
0 8-12 13-18 19-24
> 24 6
2 0
0 2
0 0
0 3
2 0
0 3
2 0
0 4
0 0
0 3
0 0
0 5
1 0
0 3
0 0
0 3
1 0
0 1
1 1
4 3
1 0
0 1
3 0
0 2
1 0
1 8
11 9
7 5
8 11 7
0 2
3 0
0 0
0 0
Total 8
4 5
6 6
4 6
3 4
7 5
5 4
35 31 5
0 Total 0
8 52 35 24 19 138 Hours of calm in this stability class:
Hours of missing wind measurements in this Hours of missing stability measurements in 0
stability class:
all stability cl 2
asses:
14 36
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 2 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, January - March, 2009 Oyster Creek Alpha Period of Record: January -
- March, 2009 Stability Class D - Neutral 380Ft-33Ft Delta-T (F)
Winds Measured at 380 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24
> 24 Total N
NNE NE ENE 1
2 1
3 7
20 8
15 16 6
4 8
33 26 10 0
E ESE SE 2
3 3
1 1
5 8
4 4
5 2
9 8
11 3
1 5
5 3
3 0
0 0
2 0
37 0
45 0
78 0
27 0
21 0
10 0
21 0
18 0
41 SSE 1
11 S
WNW NW 2
1 0
5 18 15 4
19 12 0
2 11 1
3 11 8
10 55 2
8 0
16 3
26 0
12 20 8
9 11 60 1
2 0
0 5
13 22 40 22 103 5
36 36 45 52 176 NNW Variable Total 7
12 38 24 3
84 0
0 0
240 0
164 0
0 20 80 213 101 818 Hours of calm in this stability class:
0 Hours of missing wind measurements in this stability class:
3 Hours of missing stability measurements in all stability classes:
14 37
Table D - 2 Oyster Creek 2009 Annual Radioactive Effluent Release Report Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, January - March, 2009 Oyster Creek Alpha Period of Record: January - March, 2009 Stability Class E - Slightly Stable
- 380Ft-33Ft Delta-T (F)
Winds Measured at 380 Feet Wind Direction N
NNE NE ENE E
WNW NW NNW Variable Wind Speed (in mph) 1-3 4-7 8-12 13-18 19-24
> 24 Total 8
4 1
3 5
1 0
1 8
6 13 2
13 8
14 6
0 2
3 1
6 3
1 0
1 17 17 11 8
16 28 37 20 0
2 2
9 6
3 2
0 1
9 30 16 9
35 68 59 43 0
0 0
0 2
0 3
0 0
0 5
2 7
11 10 10 3
0 21 12 12 20 13 14 4
6 34 58 44 28 80 117 123 77 0
Total 13 39 93 171 294 53 663 Hours of calm in Hours of missing this stability class:
wind measurements in this 0
stability class:
0 all stability classes:
Hours of missing stability measurements in 14 38
Oyster Creek 2009 Annual Radioactive Effluent Release Report Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, January - March, 2009 Table D - 2 Oyster Creek Alpha Stability Wind Directior N
NNE NE ENE E
WNW NW NNW Variable Total Period of Record: January -
- March, 2009 Class F - Moderately Stable 380Ft-33Ft Delta-T (F)
Winds Measured at 380 Feet Wind Speed (in mph) 1-3 4-7 8-12 13-18 19-24
> 24 Total 1
0 1
0 0
1 0
0 0
1 1
1 1
0 0
0 0
8 1
0 0
1 1
0 1
0 0
0 1
1 3
1 0
0 2
0 1
2 0
0 1
1 2
0 0
0 0
1 0
0 0
1 0
0 0
0 0
1 0
0 4
0 11 0
0 0
0 0
0 0
1 2
2 2
3 1
2 8
1 3
10 7
2 3
12 1
3 10 4
2 14 4
24 19 3
21 11 3
6 28 2
23 2
20 5
21 6
28 6
56 1
37 3
40 0
0 0
0 0
7 18 29 71 106 26 257 Hours of calm in this stability class:
Hours of missing wind measurements in this Hours of missing stability measurements in 0
stability class:
0 all stability classes:
14 39
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 2 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, January - March, 2009 Oyster Creek Alpha Period of Record: January - March, 2009 Stability Class G - Extremely Stable
- 380Ft-33Ft Delta-T (F)
Winds Measured at 380 Feet Wind Direction N
NNE NE ENE E
WNW NW NNW Variable Wind Speed (in mph) 1-3 4-7 8-12 13-18 19-24
> 24 Total 3
8 9
2 0
0 0
3 9
8 6
12 20 30 13 12 0
Total 1
8 44 52 28 2
135 Hours of calm in Hours of missing this stability class:
wind measurements in this 0
stability class:
0 all stability classes:
Hours of missing stability measurements in 14 40
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 3 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, April - June, 2009 Oyster Creek Alpha Period of Record: April - June 2009 Stability Class A - Extremely Unstable
- 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Direction N
NNE Wind Speed (in mph) 4-7 8-12 13-18 19-24
> 24 Total 1-3 0
0 8
7 0
3 9
NE ENE E
ESE 0
12 0
20 32 0
15 23 0
21 28 0
0 0
2 0
0 0
0 0
0 5
19 8
19 S
5 26 21 0
0 0
0 0
0 0
0 3
0 0
0 6
0 0
0 0
9 0
8 0
10 0
21 0
54 0
38 0
49 0
24 0
30 0
5 0
12 13 0
16 27 0
3 2
8 0
9 W
1 4
34 0
28 0
45 0
53 0
36 0
30 0
5 14 17 NW NNW Variable Total 1
13 10 0
0 7
0 2
0 264 6
0 0
62 0
0 9
0 2
162 0
499 Hours of calm in this Hours of missing wind stability class:
measurements in this 0
stability class:
2 all stability classes:
Hours of missing stability measurements in 33 41
Table D - 3 Oyster Creek 2009 Annual Radioactive Effluent Release Report Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, April - June, 2009 Oyster Creek Alpha Period of Record: April - June 2009 Stability Class B - Moderately Unstable
- 15OFt-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24
> 24 Total N
NNE NE ENE E
0 1
0 0
0 1
0 1
0 1
0 0
2 0
0 1
0 0
5 4
3 4
7 2
1 4
1 3
3 0
3 4
4 0
2 0
0 3
5 1
0 3
7 2
3 1
1 0
3 1
0 0
0 0
1 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 9
2 5
2 6
4 7
9 0
WNW NW NNW Variable Total 0
0 0
0 0
0 0
0 4
6 4
4 3
7 6
0 7
48 32 0
91 Hours of calm in Hours of missing Hours of missing this stability class:
wind measurements in this stability measurements in 0
stability class:
0 all stability classes:
33 42
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 3 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, April - June, 2009 Oyster Creek Alpha Period of Record: April -
June 2009 Stability Class C - Slightly Unstable 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24
> 24 Total N
NNE NE ENE E
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 2
2 6
9 0
5 1
2 5
1 4
2 2
3 2
NNW Variable 4
0 Total 1
28 17 4
0 0
50 Hours of Hours of Hours of calm in missing missing this stability class:
wind measurements in this stability measurements in 0
stability class:
all stability cl 0
asses:
33 43
Oyster Creek 2009 Annual Radioactive Effluent Release Report Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, April - June, 2009 Table D - 3 Oyster Creek Alpha Period of Record: April - June 2009 Stability Class D - Neutral 150Ft-33Ft Winds Measured at 33 Feet Delta-T (F)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable Wind Speed (in mph) 1-3 4-7 8-12 13-18 19-24
> 24 Total 7
6 13 2
2 0
8 9
7 4
2 3
3 1
5 7
0 9
24 47 36 26 17 14 18 20 14 12 13 6
8 10 18 0
6 17 45 28 18 7
6 18 20 6
7 1
5 0
5 6
0 0
3 5
6 1
0 0
2 10 1
0 1
0 2
0 0
0 31 22 50 110 72 47 24 28 47 57 25 21 18 14 11 20 31 0
Total 79 292 195 0
0 597 Hours of calm in this stability class:
0 Hours of missing wind measurements in this stabili Hours of missing stability measurements in all sta ty class:
bility cl 12 asses:
33 44
Table D - 3 Oyster Creek 2009 Annual Radioactive Effluent Release Report Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, April - June, 2009 Oyster Creek Alpha Period of Record: April - June 2009 Stability Class E - Slightly Stable 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 Total 6
13 14 9
9 5
7 13 6
5 17 7
7 6
9 8
0 9
8 24 11 9
17 7
13 25 55 48 40 19 16 20 18 0
0 1
3 0
1 2
5 7
9 9
7 11 7
3 6
0 15 22 41 20 20 24 19 33 40 69 72 60 43 32 32 32 0
Total 141 339 82 12 0
0 574 Hours of calm in Hours of missing Hours of missing this stability class:
wind measurements in this stability measurements in 1
stability class:
12 all stability classes:
33 45
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 3 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, April - June, 2009 Oyster Creek Alpha Period of Record: April - June Stability Class F - Moderately Stable Winds Measured at 33 Feet 2009 150Ft-33Ft Delta-T (F)
Wind Speed (in mph)
Wind Direction 1-3 4-7 N
1 NNE 0
NE 1
ENE 1
E 1
ESE 0
SE 1
SSE 2
S 2
SSW 5
SW 8
WSW 6
W 10 WNW 4
NW 6
NNW 1
Variable 0
1 0
1 0
1 0
0 0
1 5
30 18 8
11 9
5 0
8-12 13-18 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 19-24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
> 24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
Total 2
0 2
1 2
0 1
2 3
10 38 24 18 15 15 6
0 Total 49 90 0
0 0
0 139 Hours of calm in Hours of missing this stability class:
wind measurements in this 0
stability class:
2 all stability classes:
Hours of missing stability measurements in 33 46
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 3 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, April - June, 2009 Oyster Creek Alpha Period of Record: April - June Stability Class G -
Extremely Stable Winds Measured at 33 Feet 2009 15OFt-33Ft Delta-T (F)
Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 3
1 3
0 0
0 0
0 3
5 15 33 31 19 11 6
1 1
0 0
0 0
0 0
0 1
0 6
19 4
4 3
2 0
8-12 13-18 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 19-24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
> 24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
Total 4
1 3
0 0
0 0
0 4
5 21 52 35 23 14 8
1 Total 131 40 0
0 0
0 171 Hours of calm in this stability class:
0 Hours of missing wind measurements in this s Hours of missing stability measurements in a.
tability class:
11 stability cl 1
asses:
33 47
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 4 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, April - June, 2009 Oyster Creek Alpha Period of Record: April - June 2009 Stability Class A - Extremely Unstable 380Ft-33Ft Winds Measured at 380 Feet Delta-T (F)
Wind Speed (in mph)
Wind Direction 1-3 4-7 N
0 NNE 0
NE 0
ENE 0
E 0
ESE 0
SE 0
SSE 0
S 0
SSW 0
SW 0
WSW 0
W 0
WNW 0
NW 0
NNW 0
Variable 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 8-12 13-18 19-24
> 24 0
0 0
0 0
0 0
0 2
5 0
0 4
10 2
0 6
2 0
0 5
1 0
0 2
1 0
0 0
3 0
0 0
8 0
0 0
0 1
0 3
0 0
0 3
4 5
0 4
4 2
1 0
8 9
10 1
3 2
8 0
0 0
0 0
0 0
0 Total 0
0 7
16 8
6 3
3 8
1 3
12 11 27 14 0
0 Total 0
0 30 49 21 19 119 Hours of calm in Hours of missing this stability class:
0 wind measurements in this stability class:
0 Hours of missing stability measurements in all stability classes:
37 48
Table D - 4 Oyster Creek 2009 Annual Radioactive Effluent Release Report Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, April - June, 2009 Oyster Creek Alpha Period of Record: April - June 2009 Stability Class B - Moderately Unstable
- 380Ft-33Ft Delta-T (F)
Winds Measured at 380 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 Total 1
1 1
8 6
14 7
4 1
1 4
6 3
3 4
1 0
0 0
1 5
2 4
0 3
11 4
0 2
7 8
1 0
0 1
2 5
13 9
18 8
7 18 9
5 14 14 18 8
1 0
Total 0
9 65 48 20 8
150 Hours of calm in Hours of missing this stability class:
wind measurements in this 0
stability class:
all stability cl 0
asses:
Hours of missing stability measurements in 37 49
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 4 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, April - June, 2009 Oyster Creek Alpha Stability Wind Direction N
NNE NE ENE E
Period of Record: April -
June 2009 Class C - Slightly Unstable 380Ft-33Ft Delta-T (F)
Winds Measured at 380 Feet Wind Speed (in mph) 1-3 0
0 0
0 0
4-7 8-12 13-18 19-24
0 0
0 0
0 0
0 0
0 0
0 3
1 1
0 0
2 3
0 1
0 3
3 4
0 2
0 0
5 2
9 5
5 5
2 8
3 1
3 0
1 5
3 3
0 0
0 2
1 4
4 1
0 4
9 0
3 3
5 6
3 0
0 0
0 1
0 0
0 0
2 3
2 4
1 1
1 0
0 0
0 0
12 0
0 7
9 8
3 0
11 0
0 6
8 2
12 0
13 0
8 W
WNW NW NNW Variable Total 0
10 2
11 2
13 1
13 0
0 6
0 0
23 60 45 15 7
150 Hours of calm in Hours of missing Hours of missing this stability class:
wind measurements in this stability measurements in 0
stability class:
2 all stability classes:
37 50
Table D - 4 Oyster Creek 2009 Annual Radioactive Effluent Release Report Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, April - June, 2009 Oyster Creek Alpha Period of Record: April - June 2009 Stability Class D - Neutral
- 380Ft-33Ft Delta-T (F)
Winds Measured at 380 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 Total 6
13 38 11 14 17 12 8
17 9
5 5
6 6
5 6
0 17 9
37 20 31 23 23 13 20 19 9
3 8
2 7
14 0
14 7
30 36 13 13 8
6 13 29 20 14 13 2
5 16 0
4 2
17 28 7
1 1
10 13 15 9
6 9
8 3
3 0
0 0
29 11 7
0 0
0 1
10 0
0 9
11 3
2 0
41 32 152 107 73 55 45 38 65 83 43 28 45 29 25 41 0
Total 11 178 255 239 136 83 902 Hours of calm in Hours of missing this stability class:
wind measurements in this 0
stability class:
16 all stability classes:
Hours of missing stability measurements in 37 51
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 4 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, April - June, 2009 Oyster Creek Alpha Period of Record: April - June 2009 Stability Class E - Slightly Stable
- 380Ft-33Ft Delta-T (F)
Winds Measured at 380 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 Total 4
6 3
2 4
4 3
2 18 9
10 8
4 3
3 2
0 14 0
4 2
2 2
6 4
10 26 33 27 16 11 3
14 0
2 0
3 0
0 2
2 2
0 12 27 15 16 14 6
15 0
23 12 18 9
11 19 17 16 33 56 79 62 45 34 18 37 0
Total 10 65 85 174 116 39 489 Hours of calm in this stability class:
0 Hours of missing wind measurements in this stability class:
9 Hours of missing stability measurements in all stability classes:
37 52
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 4 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, April - June, 2009 Oyster Creek Alpha Period of Record: April - June 2009 Stability Class F - Moderately Stable
- 380Ft-33Ft Delta-T (F)
Winds Measured at 380 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 Total 3
3 1
0 0
0 0
1 3
5 5
9 6
3 6
10 0
1 0
0 0
0 0
0 0
0 0
17 19 9
4 12 2
0 6
6 8
6 3
4 2
8 5
6 35 35 28 11 27 12 0
Total 4
27 30 55 64 22 202 Hours of calm in this stability class:
1 Hours of missing wind measurements in this stability class:
2 Hours of missing stability measurements in all stability classes:
37 53
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 4 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, April - June, 2009 Oyster Creek Alpha Period of Record: April - June Stability Class G - Extremely Stable Winds Measured at 380 Feet 2009 38OFt-33Ft Delta-T (F)
Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 N
0 NNE 1
NE 1
ENE 0
E 0
ESE 0
SE 0
SSE 0
S 0
SSW 0
SW 0
WSW 0
W 0
WNW 1
NW 0
NNW 0
Variable 0
0 2
1 3
1 1
1 0
2 0
1 1
0 0
2 0
1 0
19-24 0
4 0
0 0
0 0
0 0
0 6
8 4
2 5
0 0
> 24 0
0 0
0 0
0 0
0 0
0 4
1 1
0 0
0 0
Total 0
10 3
9 2
3 3
2 2
3 15 12 14 12 14 1
0 Total 3
14 36 17 29 6
105 Hours of calm in Hours of missing this stability class:
wind measurements in this 0
stability class:
0 all stability classes:
Hours of missing stability measurements in 37 54
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 5 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, July - September, 2009 Oyster Creek Alpha Period of Record: July - September 2009 Stability Class A - Extremely Unstable
- 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction N
NNE 1-3 1
1 4-7 8-12 13-18 19-24
> 24 Total 8
5 0
4 NE ENE E
10 22 0
18 17 0
24 12 0
18 16 0
19 37 0
0 1
0 0
0 0
2 9
1 0
S 1
0 0
6 26 4
22 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
10 0
34 0
35 0
36 0
34 0
56 0
35 0
35 0
10 0
14 0
23 0
37 0
31 0
33 0
15 0
4 5
4 0
10 0
8 13 1
18 18 0
17 14 NW NNW Variable Total 0
28 2
12 5
1 0
216 2
0 0
0 0
0 15 0
0 0
0 7
209 0
447 Hours of calm in this Hours of missing wind stability class:
measurements in this 0
stability class:
0 all stability classes:
Hours of missing stability measurements in 132 55
Oyster Creek 2009 Annual Radioactive Effluent Release Report Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, July - September, 2009 Table D - 5 Oyster Creek Alpha Period of Record: July -
September 2009 Stability Class B - Moderately Unstable 150Ft-33Ft Winds Measured at 33 Feet Delta-T (F)
Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 Total 3
3 13 5
7 3
15 9
9 3
5 9
4 13 9
5 0
Total 14 58 38 5
0 0
115 Hours of calm in this stability class:
Hours of missing wind measurements in this Hours of missing stability measurements in 0
stability class:
0 all stability classes:
132 56
Table D - 5 Oyster Creek 2009 Annual Radioactive Effluent Release Report Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, July - September, 2009 Oyster Creek Alpha Period of Record: July - September 2009 Stability Class C - Slightly Unstable
- 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 Total Total 2
35 14 2
0 0
53 Hours of calm in this stability class:
Hours of missing wind measurements in this Hours of missing stability measurements in 0
stability class:
0 all stability classes:
132 57
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 5 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, July - September, 2009 Oyster Creek Alpha Period of Record: July - September 2009 Stability Class D - Neutral
- 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 Total 4
19 13 9
7 8
19 17 18 8
8 10 9
13 11 8
0 0
0 18 13 3
6 5
2 23 3
2 3
0 3
0 2
0 83 8
21 38 26 13 15 24 22 47 13 13 13 11 i9 14 11 0
Total 35 181 9
0 0
308 Hours of calm in Hours of missing this stability class:
wind measurements in this 0
stability class:
2 all stability classes:
Hours of missing stability measurements in 132 58
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 5 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, July - September, 2009 Oyster Creek Alpha Period of Record: July - September 2009 Stability Class E - Slightly Stable
- 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 7 8-12 13-18 19-24
> 24 Total N
NNE NE ENE E
WNW NW 10 3
0 2
0 4
5 15 10 30 30 10 4
18 16 2
12 10 4
20 7
17 6
17 6
2 0
0 13 0
26 0
80 0
41 0
24 0
30 0
26 0
23 0
58 0
53 0
59 0
58 0
48 0
16 0
40 0
19 10 33 15 10 38 13 43 17 40 24 22 5
3 1
2 0
0 0
0 9
7 19 21 4
15 NNW Variable 0
0 0
0 0
0 0
0 0
Total 154 351 92 17 0
614 Hours of calm in this stability class:
1 Hours of missing wind measurements in this stability class:
1 Hours of missing stability measurements in all stability classes:
132 59
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 5 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, July-September, 2009 Oyster Creek Alpha Period of Record: July - September 2009 Stability Class F - Moderately Stable
- 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable Total 1-3 4-7 8-12 13-18 19-24
> 24 Total 0
1 2
0 2
2 2
9 10 12 14 21 16 14 16 7
0 128 1
1 0
0 0
0 0
0 2
3 20 12 5
6 9
9 0
68 1
2 2
0 2
2 2
9 12 15 34 33 21 20 25 16 0
0 196 Hours of calm in this stability class:
0 Hours of missing wind measurements in this stabili Hours of missing stability measurements in all sta ty class:
0 bility classes:
132 60
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 5 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, July - September, 2009 Stability Wind Direction N
NNE NE ENE E
WNW NW NNW Variable Oyster Creek Alpha Period of Record: July -
September 2009 Class G - Extremely Stable 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph) 1-3 4-7 8-12 13-18 19-24
> 24 Total 2
0 1
0 0
2 1
2 5
6 18 98 80 38 39 8
0 2
0 1
0 0
2 1
2 5
6 20 115 83 42 47 13 0
Total 300 39 0
0 0
0 339 Hours of calm in this stability class:
Hours of missing Hours of missing wind measurements in this stability measurements in 0
stability class:
0 all stability classes:
132 61
Table D - 6 Oyster Creek 2009 Annual Radioactive Effluent Release Report Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, July - September, 2009 Oyster Creek Alpha Period of Record:. July - September 2009 Stability Class A - Extremely Unstable
- 380Ft-33Ft Delta-T (F)
Winds Measured at 380 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 Total Total 0
1 14 25 4
0 44 Hours of calm in this stability class:
Hours of missing wind measurements in this Hours of missing stability measurements in 0
stability class:
0 all stability classes:
134 62
Table D - 6 Oyster Creek 2009 Annual Radioactive Effluent Release Report Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, July - September, 2009 Oyster Creek Alpha Period of Record: July - September 2009 Stability Class B - Moderately Unstable
- 380Ft-33Ft Delta-T (F)
Winds Measured at 380 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 Total 1
0 5
7 10 11 13 11 1
4 3
1 3
9 10 3
0 0
0 6
3 1
3 0
4 15 1
2 1
7 4
5 1
0 4
0 11 13 13 16 16 15 18 8
8 2
12 15 15 6
0 Total 0
19 92 53 8
0 172 Hours of calm in this stability class:
0 Hours of missing wind measurements in this stabili ty class:
0 Hours of missing stability measurements in all stabi lity classes:
134 63
Oyster Creek 2009 Annual Radioactive Effluent Release Report Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, July - September, 2009 Table D - 6 Oyster Creek Alpha Period of Record: July -
September 2009 Class C - Slightly Unstable 380Ft-33Ft Winds Measured at 380 Feet Stability Delta-T (F)
Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24
> 24 Total N
NNE NE ENE E
WNW NW NNW Variable 1
1 5
3 6
4 8
16 6
3 2
3 4
7 13 7
0 4
2 16 12 11 12 13 21 15 14 8
10 18 18 23 14 0
Total 2
46 89 61 A
5 211 Hours of calm in this stability class:
0 Hours of missing wind measurements in this stability class:
0 Hours of missing stability measurements in all stability classes:
134 64
Oyster Creek 2009 Annual Radioactive Effluent Release Report Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, July - September, 2009 Table D - 6 Oyster Creek Alpha Period of Record: July -
September 2009 Stability Class D - Neutral 380Ft-33Ft Delta-T (F)
Winds Measured at 380 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24
> 24 Total N
NNE NE ENE E
WNW NW NNW Variable 2
5 8
3 13 12 9
5 7
6 8
2 1
2 3
10 0
3 9
19 6
7 12 23 28 32 14 10 7
7 11 20 7
0 1
5 30 36 17 10 17 12 26 30 12 13 11 11 7
11 0
1 0
8 15 8
2 2
2 4
17 1
1 3
2 1
0 0
0 0
20 40 0
0 0
0 0
0 0
0 0
0 0
0 0
9 20 86 101 48 36 51 48 70 68 31 25 24 26 31 30 0
Total 17 96 215 249 67 60 704 Hours of calm in Hours of missing this stability class:
wind measurements in this 0
stability class:
2 all stability classes:
Hours of missing stability measurements in 134 65
Oyster Creek 2009 Annual Radioactive Effluent Release Report Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, July-September, 2009 Table D - 6 Stability C
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable Oyster Creek Alpha Period of Record: July -
September 2009 flass E - Slightly Stable 380Ft-33Ft Delta-T (F)
Winds Measured at 380 Feet Wind Speed (in mph) 1-3 4-7 0
2 4
3 1
1 0
0 0
2 0
0 0
0 0
0 0
7 6
4 1
0 2
4 2
4 4
3 2
0 9
3 2
0 8-12 13-18 19-24
> 24 14 12 4
0 6
10 0
0 7
5 0
0 12 15 2
0 4
4 1
0 2
0 0
0 10 3
0 0
14 6
0 0
14 10 1
0 8
40 2
0 9
40 7
0 11 24 13 0
7 20 16 0
5 16 4
0 8
7 0
0 7
11 6
0 0
0 0
0 Total 37 24 20 33 10 5
17 22 29 56 59 50 43 34 18 26 0
Total 13 53 138 223 56 0
483 Hours of calm in this stability class:
0 Hours of missing wind measurements in this stability class:
1 Hours of missing stability measurements in all stability classes:
134 66
Table D - 6 Oyster Creek 2009 Annual Radioactive Effluent Release Report Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, July - September, 2009 Oyster Creek Alpha Period of Record: July - September 2009 Stability Class F - Moderately Stable
- 380Ft-33Ft Delta-T (F)
Winds Measured at 380 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 Total 12 6
2 4
0 0
0 3
8 5
7 7
8 14 4
6 0
8 2
2 0
0 0
0 0
0 4
9 8
11 21 18 10 0
3 1
0 0
0 0
0 0
0 0
6 16 6
13 5
10 0
24 16 6
6 0
3 0
4 9
12 27 35 30 50 30 29 0
Total 9
30 86 93 60 3
281 Hours of calm in Hours of missing this stability class:
wind measurements in this 0
stability class:
0 all stability classes:
Hours of missing stability measurements in 134 67
Oyster Creek 2009 Annual Radioactive Effluent Release Report Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, July - September, 2009 Table D - 6 Oyster Creek Alpha Stability Wind Direction N
NNE Period of Record: July -
September 2009 Class G -
Extremely Stable 380Ft-33Ft Delta-T (F)
Winds Measured at 380 Feet Wind Speed (in mph) 1-3 0
0 4-7 8-12 13-18 19-24
> 24 Total 1
2 1
5 NE ENE E
0 0
0 0
1 1
2 0
0 0
0 0
4 5
3 7
3 0
0 2
5 3
4 5
6 5
0 0
0 2
1 0
0 3
6 3
3 0
0 0
0 0
0 0
0 0
1 4
2 1
3 0
0 0
15 0
11 0
12 0
3 0
0 7
0 0
0 5
0 11 0
13 0
10 0
0 0
4 5
0 8
W 4
14 0
14 0
28 0
28 0
13 WNW 1
10 5
10 NW 1
0 0
1 2
0 3
2 0
7 1
0 0
0 8
0 Variable Total 4
45 63 47 17 0
176 Hours of calm in this stability class:
0 Hours of missing wind measurements in this stability class:
0 Hours of missing stability measurements in all stability classes:
134 68
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 7 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, October - December, 2009 Oyster Creek Alpha Stability Wind Directior Period of Record: October -
December 2009 Class A - Extremely Unstable 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph) 1l 1-3 4-7 8-12 13-18 19-24
> 24 Total N
NNE NE ENE E
0 0
0 0
0 0
1 0
0 0
0 0
0 7
1 0
0 0
8 0
12 0
0 0
0 0
0 0
0 0
7 6
1 4
9 7
2 7
3 S
8 15 8
25 1
9 WNW NW NNW Variable Total 0
12 24 10 0
0 0
0 0
0 0
10 0
24 0
42 0
46 0
12 0
0 9
0 3
0 0
0 0
0 1
83 92 24 0
200 Hours of calm in this stability class:
Hours of missing wind measurements in this Hours of missing stability measurements in 0
stability class:
1 all stability classes:
14 69
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 7 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, October - December, 2009 Oyster Creek Alpha Stability Period of Record: October - December 2009 Class B - Moderately Unstable 15OFt-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
1-3 0
0 0
0 0
4-7 8-12 13-18 19-24
WNW 0
0 0
0 2
0 0
0 0
1 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
3 4
7 3
0 2
3 1
3 4
2 5
8 NW NNW Variable Total 3
8 0
7 5
0 6
0 0
0 0
0 0
0 23 0
17 0
13 0
0 3
44 35 16 0
98 Hours of calm in Hours of missing Hours of missing this stability class:
wind measurements in this stability measurements in 0
stability class:
I all stability classes:
14 70
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 7 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, October - December, 2009 Oyster Creek Alpha Period of Record: October -
December 2009 Stability Class C - Slightly Unstable
- 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24
> 24 Total N
0 0
0 0
0 0
0 NNE 0
0 0
0 0
0 0
NE 0
4 1
0 0
0 5
ENE 0
1 0
0 0
0 1
E 0
2 0
0 0
0 2
ESE 0
0 0
0 0
0 0
SE 0
0 0
0 0
0 0
SSE 0
0 0
0 0
0 0
S 0
0 1
4 0
0 5
SSW 0
0 0
1 0
0 1
SW 0
0 0
0 0
0 0
WSW 0
1 0
0 0
0 1
W 0
0 1
1 0
0 2
WNW 1
3 8
0 0
0 12 NW 0
0 5
2 0
0 7
NNW 3
1 0
0 0
0 4
Variable 0
0 0
0 0
0 0
Total 4
12 16 8
0 0
40 Hours of calm in this stability class:
0 Hours of missing wind measurements in this stability class:
0 Hours of missing stability measurements in all stability classes:
14 71
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 7 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, October - December, 2009 Oyster Creek Alpha Period of Record: October - December 2009 Stability Class D - Neutral
- 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 Total 10 48 32 3
1 4
5 1
8 4
2 4
10 15 15 26 0
22 45 25 9
3 1
3 3
5 2
3 2
8 17 23 12 0
39 100 64 22 6
5 10 7
20 9
5 9
21 44 49 46 0
Total 45 188 183 40 0
0 456 Hours of calm in Hours of missing Hours of missing this stability class:
wind measurements in this stability measurements in 0
stability class:
0 all stability classes:
14 72
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 7 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, October - December, 2009 Oyster Creek Alpha Period of Record: October -
December 2009 Stability Class E - Slightly Stable
- 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 14 11 2
2 0
2 1
5 3
6 4
4 11 5
9 7
0 21 35 19 16 14 5
6 16 14 10 16 20 46 47 35 26 0
8-12 13-18 19-24
> 24 10 0
0 0
32 35 3
0 31 5
0 0
28 12 0
0 5
4 0
0 11 5
0 0
7 3
0 0
12 1
1 0
11 10 0
0 9
5 0
0 12 1
0 0
2 2
0 0
19 3
0 0
31 5
0 0
40 9
0 0
13 0
0 0
0 0
0 0
Total 45 116 57 58 23 23 17 35 38 30 33 28 79 88 93 46 0
Total 86 346 273 100 4
0 809 Hours of calm in this stability class:
0 Hours of missing wind measurements in this stability class:
2 Hours of missing stability measurements in all stability classes:
14 73
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 7 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, October - December, 2009 Oyster Creek Alpha Period of Record: October -
December 2009 Stability Class F - Moderately Stable
- 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 Total 3
1 1
1 1
0 0
2 0
1 11 13 13 15 14 6
0 3
1 2
5 1
0 1
1 5
5 3
24 31 31 27 7
0 6
4 3
6 2
0 1
3 7
6 14 38 44 46 41 13 0
Total 82 147 2
3 0
0 234 Hours of calm in this stability class:
Hours of missing wind measurements in this Hours of missing stability measurements in 0
stability class:
0 all stability classes:
14 74
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 7 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, October - December, 2009 Oyster Creek Alpha Period of Record: October - December 2009 Stability Class G - Extremely Stable
- 150Ft-33Ft Delta-T (F)
Winds Measured at 33 Feet Wind Direction N
NNE NE ENE E
WNW NW NNW Variable Wind Speed (in mph) 1-3 4-7 8-12 13-18 19-24
> 24 Total 3
1 2
1 1
0 0
4 3
5 9
63 55 49 37 13 0
0 0
0 0
0 1
0 1
0 0
4 31 21 15 14 19 0
3 1
2 1
1 1
0 5
3 5
13 94 76 64 51 32 0
Total 246 106 0
0 0
0 352 Hours of calm in Hours of missing this stability class:
wind measurements in this 0
stability class:
1 all stability classes:
Hours of missing stability measurements in 14 75
Table D - 8 Oyster Creek 2009 Annual Radioactive Effluent Release Report Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, October - December, 2009 Oyster Creek Alpha Period of Record: October -
December 2009 Stability Class A - Extremely Unstable
- 380Ft-33Ft Delta-T (F)
Winds Measured at 380 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable Total 1-3 4-7 8-12 13-18 19-24
> 24 Total 0
7 Hours of calm in Hours of missing this stability class:
0 wind measurements in this stab)ility class:
0 stability classes:
Hours of missing stability measurements in all 14 76
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 8 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, October - December, 2009 Oyster Creek Alpha Period of Record: October -
December 2009 Stability Class B - Moderately Unstable 380Ft-33Ft Winds Measured at 380 Feet Delta-T (F)
Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 Total 0
4 3
4 0
0 2
0 1
5 1
1 11 13 21 6
0 Total 0
4 20 28 13 7
72 Hours of calm in this stability class:
0 Hours of missing wind measurements in this stability class:
0 Hours of missing stability measurements in all stability classes:
14 77
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 8 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, October - December, 2009 Oyster Creek Alpha Period of Record: October -
December 2009 Stability Class C - Slightly Unstable 380Ft-33Ft Delta-T (F)
Winds Measured at 380 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
1-3 0
0 0
0 0
4-7 8-12 13-18 19-24
> 24 Total 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
2 3
7 2
1 2
3 1
1 2
0 3
1 6
WNW NW NNW Variable 2
3 3
10 2
3 10 6
0 0
4 8
6 0
1 11 5
24 9
28 2
21 0
0 0
0 Total 0
18 41 25 21 20 125 Hours of Hours of Hours of calm in missing missing this stability class:
wind measurements in this stability measurements in 0
stability class:
0 all stability classes:
14 78
Table D.- 8 Oyster Creek 2009 Annual Radioactive Effluent Release Report Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, October - December, 2009 Oyster Creek Alpha Period of Record: October -
December 2009 Stability Class D - Neutral
- 380Ft-33Ft Delta-T (F)
Winds Measured at 380 Feet Wind Speed (in mph)
Wind Direction N
NNE NE ENE E
WNW NW NNW Variable 1-3 4-7 8-12 13-18 19-24
> 24 Total 8
3 4
7 5
2 4
2 5
4 7
2 1
5 7
12 0
8 22 40 13 4
3 10 1
4 9
6 2
3 16 13 18 0
18 42 54 3
6 3
3 8
6 7
1 4
11 22 21 24 0
20 28 32 21 7
2 0
9 6
5 3
5 3
24 53 20 0
2 25 28 7
13 0
3 1
1 22 2
0 3
17 33 8
0 58 120 158 52 35 10 21 21 23 47 19 13 21 84 127 83 0
892 Total 6
78 172 233 238 165 Hours of calm in this stability class:
Hours of missing wind measurements in this Hours of missing stability measurements in 0
stability class:
3 all stability classes:
14 79
Oyster Creek 2009 Annual Radioactive Effluent Release Report Table D - 8 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, October - December, 2009 Oyster Creek Alpha Period of Record: October -
December 2009 Stability Class E - Slightly Stable 380Ft-33Ft Delta-T (F)
Winds Measured at 380 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24
> 24 Total N
NNE NE ENE E
ESE 1
1 0
0 1
6 11 15 7
12 15 2
1 2
0 0
0 0
0 S
1 1
0 2
0 1
0 2
0 1
4 1
1 0
3 10 2
27 44 8
21 10 2
2 2
4 2
4 5
3 2
0 10 11 4
49 4
15 3
4 2
3 9
5 9
5 21 6
17 7
16 2
10 1
23 2
18 4
41 2
21 5
34 8
99 5
65 0
47 1
W WNW NW NNW Variable Total 0
2 2
0 0
2 5
11 2
9 17 4
26 55 2
19 36 5
15 26 0
0 0
199 0
0 8
33 65 189 104 598 Hours of calm in Hours of missing Hours of missing this stability class:
wind measurements in this stability measurements in 1
stability class:
1 all stability classes:
14 80
Oyster Creek 2009 Annual Radioactive Effluent Release Report Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, October - December, 2009 Table D - 8 Oyster Creek Alpha Stability Wind Directior Period of Record: October -
December 2009 Class F -
Moderately Stable 380Ft-33Ft Delta-T (F)
Winds Measured at 380 Feet Wind Speed (in mph) 1 1-3 4-7 8-12 13-18 19-24
> 24 Total N
0 2
2 7
10 NNE NE ENE E
10 2
23 0
22 0
14 0
0 0
0 0
0 0
0 3
5 1
2 3
4 1
7 W
WNW NW NNW Variable Total 0
0 0
0 0
1 2
1 2
0 0
12 10 3
9 21 0
20 1
24 6
41 8
57 6
48 3
10 35 4
12 24 0
0 0
0 0
5 23 40 69 115 23 275 Hours of calm in this Hours of missing wind stability class:
0 measurements in this stability class:
0 Hours of missing stability measurements in all stability classes:
14 81
Table D - 8 Oyster Creek 2009 Annual Radioactive Effluent Release Report Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Nuclear Generating Station, October - December, 2009 Oyster Creek Alpha Period of Record: October -
December 2009 Stability Class G - Extremely Stable 380Ft-33Ft Delta-T (F)
Winds Measured at 380 Feet Wind Speed (in mph)
Wind Direction 1-3 4-7 8-12 13-18 19-24
> 24 Total N
NNE NE ENE E
WNW NW NNW Variable 4
11 2
0 0
0 0
2 1
1 2
10 5
16 17 2
0 10 1
0 0
0 1
1 0
3 1
8 14 10 7
9 0
7 17 25 5
1 1
0 2
5 4
7 14 27 24 33 30 24 0
Total 4
26 30 73 72 14 219 Hours of calm in this stability class:
Hours of missing wind measurements in this Hours of missing stability measurements in 0
stability class:
1 all stability classes:
14 82
Oyster Creek 2009 Annual Radioactive Effluent Release Report Appendix E ODCM Revisions CY-OC-170-301 Revision 3 CY-OC-170-301 Revision 4 83
Oyster Creek 2009 Annual Radioactive Effluent Release Report 84
Oyster Creek 2009 Annual Radioactive Effluent Release Report Appendix F ERRATA 85