Page 129 07JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Docket Nos. 50-206, 50-361, 50-362 23 'Reporting period: January 1, 1980 to December 31, 1980 03 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported Ot.c of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements Table 1A 0

Direct Radiation Quarterly Composite (millirem)

-n Gamma Exposure 276 5.0000 24.111(105/268) Huntington Beach 31.075( 4/ 4) 21.350( 2/ 8) 0 IC (18.300-38.200) Generating Station (25.100-38.200) (19.900-22.800) 37 mi.

NW Table 1B Direct Radiation Annual Composite (millirem)

Gamma Exposure 69 5.0000 76.000( 16/ 67)

Huntington Beach 92.000( 1/ 1) <LLD ( 0/ 2) 0 (61.000-92.000) Generating Station (92.000-92.000) 37 mi.

NW Table 2 Airborne Weekly Composite (pCi/cu.m)

Gross Beta 520 0.0011 0.0373(146/468) Units 2/3 0.0458( 51/ 52) 0.0392( 48/ 52) 0 0.004- 0.178) Switchyard

( 0.008- 0.177) ( 0.010- 0.194) 0.13 mi.

NNE Table 3 Airborne Weekly Composite (pCi/cu.m) 1-131 520 0.0430 0.2500( 2/468) Units 2/3 0.2500( 2/ 52) <LLD ( 0/ 52) 0

( 0.140- 0.360) Switchyard

( 0.140- 0.360) 0.13 mi.

NNE

Page 130 07JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1. 1980 to December 31, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements Table 4A Airborne Quarterly Composite (PCi/cu.m)

Be-7 20 0.0540 0.0606( 16/ 16)

Huntington Beach 0.0745( 4/ 4) 0.0745( 4/ 4) 0 0.026- 0.117) Generating Station ( 0.038- 0.140) ( 0.038- 0.140) 37 mi.

NW 0.002- 0.006) SDG&E Offices

( 0.006- 0.006) 5.5 mi.

NW Generating Station ( 0.002- 0.002) ( 0.002- 0.002) 37 mi.

NW Co-58 20 0.0010

<LLD ( 0/ 16) ALL <LLD

<LLD ( 0/ 4) 0 Co-60 20 0.0010

<LLD ( 0/ 16) ALL <LLD

<LLD ( 0/ 4) 0 Cs-134 20 0.0010

<LLD ( 0/ 16) ALL <LLD

<LLD ( 0/ 4) 0 Cs-137 20 0.0010 0.0016( 2/ 16) NE Site Boundary 0.0021( 1/ 4) <LLD ( 0/ 4) 0 0.001- 0.002) Visitors Center

( 0.002- 0.002) 0.2 mi.

NNE Table 4A Airborne Quarterly Composite (PCi/cu.m)

Zr(Nb)-95 20 0.0010 0.0052( 4/ 16) San Clemente City 0.0110( 1/ 4) 0.0040( 1/ 4) 0 0.002- 0.011) SDG&E Offices

( 0.011- 0.011) ( 0.004- 0.004) 5.5 mi.

NW Table 4C Airborne Quarterly Composite (pCi/cu.m)

Gross Alpha 44 0.0003 0.0011( 11/ 40) Huntington Beach 0.0020( 4/ 4) 0.0020( 4/ 4) 0 0.000- 0.002) Generating Station ( 0.001- 0.004) ( 0.001- 0.004) 37 mi.

NW Sr-90 44 0.0030 0.0002( 1/ 40) San Clemente City 0.0002( 1/ 4) <LLD ( 0/ 4) 0 0.000- 0.000) SDG&E Offices

( 0.000- 0.000) 5.5 mi.

NW

Page 131 07JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Docket Nos. 50-206, 50-361. 50-362 Reporting period: January 1, 1980 to December 31, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements Table 5 Ocean Water Monthly Composite (pCi/1)

Co-58 24 4.9000 11.000( 1/ 18)

Station Discharge 11.000( 1/ 6) <LLD ( 0/ 6) 0 (11.000-11.000) Outfall - Unit 1 (11.000-11.000) 0.5 mi.

SSW Co-60 24 5.3000 6.0000( 1/ 18) Station Discharge 6.0000( 1/ 6) <LLD ( 0/ 6) 0 6.000- 6.000) Outfall - Unit 1 ( 6.000- 6.000) 0.5 mi.

SSW Cs-134 24 4.6000 380.00( 1/ 18) Station Discharge 380.00( 1/ 6) <LLD ( 0/ 6) 0 (380.00-380.00) Outfall - Unit 1 (380.00-380.00) 0.5 mi.

SSW Cs-137 24 3.7000 430.00( 1/ 18) Station Discharge 430.00( 1/ 6) <LD ( 0/ 6) 0 (430.00-430.00) Outfall Unit 1 (430.00-430.00) 0.5 mi.

SSW Fe-59 24 8.8000

<LLD ( 0/ 18) ALL <LLD

<LLD ( 0/ 6) 0 Table 5 Ocean Water Monthly Composite (pCi/1) 1-131 24 25.500

<LLD ( 0/ 18) ALL <LLD

<LLD ( 0/ 6) 0 Mn-54 24 3.7000

<LLD ( 0/ 18) ALL <LLD

<LLD ( 0/ 6) 0 Zn-65 24 7.6000

<LLD ( 0/ 18) ALL <LD

<LLD ( 0/ 6) 0 Table 5 Ocean Water Monthly Composite (pCi/1)

Zr(Nb)-95 24 7.3000

<LLD ( 0/ 18) ALL <LLD

<LLD ( 0/ 6) 0 Table 6 Ocean Water Bi-Monthly Composite (pCi/1)

Tritium 24 105.00 882.78( 18/ 18)

Station Discharge 903.33( 6/ 6) 841.67( 6/ 6) 0 (670.00-1340.0) Outfall - Unit 1 (670.00-1340.0) (640.00-1250.0) 0.5 mi.

SSW

0 Page 132 07JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1, 1980 to December 31, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements Table 7 Ocean Water Quarterly Composite (pCi/1)

Tritium 8

102.00 1150.0( 2/ 6) Station.Discharge 1900.0( 1/ 2) <LLD ( 0/ 2) 0 (400.00-1900.0) Outfall - Unit 1 (1900.0-1900.0) 0.5 mi.

SSW Table 9B Drinking Water Monthly Composite (pCi/l)

Gross Alpha 36 0.2110 0.3500( 2/ 24) 0.6000( 1/ 12) 0.6000( 1/ 12) 0 0.300- 0.400) Huntington Beach

( 0.600- 0.600) ( 0.600- 0.600) 37 mi.

NW Gross Beta 36 0.7380 1.3458( 24/ 24) Tri-Cities Munic. 1.4833( 12/ 12) 1.1727( 11/ 12) 0 0.600- 2.700) Water Dist. Res.

( 0.800- 2.700) ( 0.800- 1.600) 8.7 mi.

NW Table 9C Drinking Water Monthly Composite (pCi/1)

Gross Alpha 36 0.4430 3.5000( 4/ 24) San Clemente 5.0000( 1/ 12) 3.0000( 4/ 12) 0 2.000- 5.000) Golf Course Well

( 5.000- 5.000) ( 2.000- 4.000) 3.5 mi.

NNW Gross Beta 36 1.4750 11.333( 24/ 24) Tri-Cities Munic. 11.750( 12/ 12) 8.0636( 11/ 12) 0 6.000-19.000) Water Dist. Res.

( 7.000-19.000) ( 3.700-13.000) 8.7 mi.

NW Table 90 Drinking Water Quarterly Composite (pCi/1)

Gross Alpha 12 0.2110 0.2000( 1/ 8) 0.4000( 1/ 4) 0.4000( 1/ 4) 0 0.200- 0.200) Huntington Beach

( 0.400- 0.400) ( 0.400- 0.400) 37 mi.

NW Gross Beta 12 0.7380 1.6125( 8/ 8) San Clemente 1.6750( 4/ 4) 1.3250( 4/ 4) 0 0.900- 2.300) Golf Course Well

( 0.900- 2.300) ( 0.900- 1.800) 3.5 mi.

NNW

Page 133 07JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1, 1980 to December 31, 1980 Type and Lower Limit All. Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements Table 9E Drinking Water Quarterly Composite (pCi/1)

Ba(La)-140 12 37.400

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 Co-58 12 5.1000

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 Co-60 12 5.4000

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 Cs-134 12 4.6000

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 Cs-137 12 3.7000

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 Table 9E Drinking Water Quarterly Composite (pCi/1)

Fe-59 12 9.5000

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 Gross Alpha 12 0.6320 3.0000( 1/ 8) Tri-Cities Munic. 3.0000( 1/ 4) 2.0000( 1/ 4) 0 3.000- 3.000) Water Dist. Res.

( 3.000- 3.000) ( 2.000- 2.000) 8.7 mi.

NW Gross Beta 12 0.6990 12.250( 8/ 8) San Clemente 12.500( 4/ 4) 8.2500( 4/ 4) 0 9.000-16.000) Golf Course Well

( 9.000-14.000) ( 6.000- 9.000) 3.5 mi.

NNW H-3 12 102.00 450.00( 2/ 8) Tri-Cities Munic. 600.00( 1/ 4) 500.00( 1/ 4) 0 (300.00-600.00) Water Dist. Res.

(600.00-600.00) (500.00-500.00) 8.7 mi.

NW 1-131 12 0.5100

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 Mn-54 12 3.7000

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 Zn-65 12 7.7000

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 Table 9E Drinking Water Quarterly Composite (pCi/1)

Zr(Nb)-95 12 7.7000

<LLD ( 0/ 8) ALL <LLD

<LLD 0/ 4) 0

0 Page 134 07JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1, 1980 to December 31, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements Table 10 Shoreline Sediment Semi-Annual Composite (pCi/g)

Co-58 8

0.0090

<LLD ( 0/ 6) ALL <LLD

<LLD ( 0/ 2) 0 Co-60 8

0.0090

<LLD ( 0/ 6) ALL <LLD

<LLD ( 0/ 2) 0 Cs-134 8

0.0080

<LLD ( 0/ 6) ALL <LLD

<LLD ( 0/ 2) 0 Cs-137 8

0.0070 0.0160( 2/ 6) San Onofre 0.0200( 1/ 2) <LLD ( 0/ 2) 0 0.012- 0.020) State Beach

( 0.020- 0.020) 0.6 mi.

SE Fe-59 8

0.0170

<LLD ( 0/ 6) ALL <LLD

<LLD ( 0/ 2) 0 Table 10 Shoreline Sediment Semi-Annual Composite (pCi/g) 1-131 8

0.0690

<LLD ( 0/ 6) ALL <LLD

<LLD ( 0/ 2) 0 Mn-54 8

0.0070

<LLD ( 0/ 6) ALL <LLD

<LLD ( 0/ 2) 0 Ra-226 8

0.0130 0.3383( 6/ 6) San Onofre 0.4600( 2/ 2) 0.2450( 2/ 2) 0 0.140- 0.700) State Beach

( 0.220- 0.700) ( 0.240- 0.250) 0.6 mi.

SE Zn-65 8

0.0140

<LLD ( 0/ 6) ALL <LLD

<LLD ( 0/ 2) 0 Table 10 Shoreline Sediment Semi-Annual Composite (pCi/g)

Zr(Nb)-95 8

0.0140

<LLD ( 0/ 6) ALL <LLD

<LLD ( 0/ 2) 0

Page 135 07JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1, 1980 to December 31, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements Table 11 Ocean Bottom Sediments Semi-Annual Composite (pCi/g) 0.260- 0.260) Unit 1 Outfall

( 0.260- 0.260) 0.6 mi.

W Co-58 10 0.0080 0.3042( 4/ 8) 0.5870( 2/ 2) <LLD (

0/ 2) 0 0.013-1.160) Unit 1 Outfall

( 0.014-1.160) 0.6 mi.

W Co-60 10 0.0080 2.0835( 4/ 8) 4.0570( 2/ 2) <LLD ( 0/ 2) 0 0.014-8.100) Unit 1 Outfall

( 0.014-8.100) 0.6 mi.

W Cs-134 10 0.0070

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 2) 0 Cs-137 10 0.0060 0.0325( 6/ 8) 0.0440( 1/ 2) 0.0430( 1/ 2) 0

( 0.014- 0.060) Unit 3 Outfall C

0.044- 0.044) ( 0.043- 0.043) 1.2 mi.

SSW Fe-59 10 0.0150

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 2) 0

Page 136 07JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1, 1980 to December 31, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements Table 11 Ocean Bottom Sediments Semi-Annual Composite (pCi/g) 1-131 10 0.0170

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 2) 0 Mn-54 10 0.0060 0.2525( 2/ 8) 0.4900( 1/ 2) <LLD ( 0/ 2) 0 0.015- 0.490) Unit 1 Outfall

( 0.490- 0.490) 0.6 mi.

W Ra-226 10 0.0120 0.3445( 8/ 8) 0.4650( 2/ 2) 0.1690( 2/ 2) 0 0.166- 0.740) Unit 2 Outfall

( 0.190- 0.740) ( 0.038- 0.300) 1.6 mi.

SW Zn-65 10 0.0120 0.2600( 1/ 8) 0.2600( 1/ 2) <LLD (

0/ 2) 0 0.260- 0.260) Unit 1 Outfall

( 0.260- 0.260) 0.6 mi.

W Table 11 Ocean Bottom Sediments Semi-Annual Composite (pCi/g)

Zr(Nb)-95 10 0.0120

<LLD (

0/ 8) ALL <LLD

<LID ( 0/ 2) 0 Table 12A Non-Migratory Marine Quarterly Composite (pCi/g) (flesh type) bay mussel Co-58 4

0.0070 0.0400( 3/ 4) 0.0470( 2/ 3) <LLD ( 0/ 0) 0 0.014- 0.080) Unit 1 Outfall

( 0.014- 0.080) 0.9 mi.

WSW bay mussel Co-60 4

0.0050 0.0383( 4/ 4) 0.1040( 1/ 1) <LLD ( 0/ 0) 0 0.010- 0.104) Units 2/3 Outfall

( 0.104- 0.104) 1.5 mi.

SSW bay mussel Cs-134 4

0.0040

<LLD ( 0/ 4) ALL <LLD

<LLD ( 0/ 0) 0 bay mussel Cs-137 4

0.0010 0.0060( 1/ 4) 0.0060( 1/ 3) <LLD ( 0/ 0) 0 0.006- 0.006) Unit 1 Outfall

( 0.006- 0.006) 0.9 mi.

WSW bay mussel Fe-59 4

0.0090

<LLD ( 0/ 4) ALL <LLD

<LLD 0/ 0) 0

0 Page 137 07JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1, 1980 to December 31, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements Table 12A Non-Migratory Marine Quarterly Composite (pCi/g) (flesh type)

(53.000-53.000) Unit 1 Outfall (53.000-53.000) 0.9 mi.

WSW bay mussel 1-131 4

0.0150

<LLD ( 0/ 4) ALL <LLD

<LLD ( 0/ 0) 0 bay mussel Mn-54 4

0.0030

<LLD ( 0/ 4) ALL <LLD

<LLD ( 0/

0) 0 Table 12A Non-Migratory Marine Quarterly Composite (pCi/g) (flesh type) bay mussel Sr-90 4

0.0200

<LLD ( 0/

4) ALL <LLD

<LLD ( 0/

0) 0 bay mussel Zn-65 4

0.0070

<LLD ( 0/

4) ALL <LLD

<LLD ( 0/ 0) 0 bay mussel Zr(Nb)-95 4

0.0070

<LLD ( 0/

4) ALL <LLD

<LLD 0/ 0) 0 black perch Co-58 12 0.0070

<LLD ( 0/

8) ALL <LLD

<LLD

( 0/ 4) 0 Table 12A Non-Migratory Marine Quarterly Composite (pCi/g) (flesh type) black perch Co-60 12 0.0050

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/

4) 0 black perch Cs-134 12 0.0040

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 black perch Cs-137 12 0.0010 0.0086( 7/ 8) 0.0110( 4/ 4) 0.0110( 4/ 4) 0 0.006- 0.010) Newport Beach

( 0.007- 0.014) ( 0.007- 0.014) 18.2 mi.

NW black perch Fe-59 12 0.0090

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 black perch H-3 Bound 12 1.4000 48.143( 7/ 8) 70.667( 3/ 4) 56.625( 4/

4) 0 (13.000-109.00) Unit 1 Outfall (13.000-109.00) ( 2.000-150.00) 0.9 mi.

WSW black perch 1-131 12 0.0150

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 black perch Mn-54 12 0.0030

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/

4) 0

Page 138 07JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1, 1980 to December 31, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements Table 12A Non-Migratory Marine Quarterly Composite (pCi/g) (flesh type) black perch Sr-90 12 0.0200

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 black perch Zn-65 12 0.0070

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 black perch Zr(Nb)-95 12 0.0070

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 keyhole limpet Ag-110m 4

0.0030 0.0597( 3/ 3) 0.0597( 3/ 3) 0.0200( 1/ 1) 0 0.033- 0.101) Units 2/3 Outfall ( 0.033- 0.101)

( 0.020- 0.020) 1.5 mi.

SSW Table 12A Non-Migratory Marine Quarterly Composite (pCi/g) (flesh type) keyhole limpet Co-58 4

0.0070 0.0540( 3/ 3) 0.0540( 3/ 3) <LLD (

0/ 1) 0 0.007- 0.101) Units 2/3 Outfall

( 0.007- 0.101) 1.5 mi.

SSW keyhole limpet Co-60 4

0.0050 0.0327( 3/ 3) 0.0327( 3/ 3) <LLD (

0/ 1) 0 0.021- 0.040) Units 2/3 Outfall ( 0.021- 0.040) 1.5 mi.

SSW keyhole limpet Cs-134 4

0.0040

<LLD (

0/ 3) ALL <LLD

<LLD ( 0/ 1) 0 keyhole limpet Cs-137 4

0.0010

<LLD ( 0/ 3) 0.0050( 1/ 1) 0.0050( 1/ 1) 0 Newport Beach

( 0.005- 0.005) ( 0.005- 0.005) 18.2 mi.

NW keyhole limpet Fe-59 4

0.0090

<LLD (

0/ 3) ALL <LLD

<LLD (

0/ 1) 0 Table 12A Non-Migratory Marine Quarterly Composite (pCi/g) (flesh type) keyhole limpet H-3 Bound 4

1.4000 1.8000( 1/ 3) 35.000( 1/ 1) 35.000( 1/ 1) 0 1.800- 1.800) Newport Beach (35.000-35.000) (35.000-35.000) 18.2 mi.

NW keyhole limpet 1-131 4

0.0150

<LLD ( 0/ 3) ALL <LLD

<LLD 0/ 1) 0 keyhole limpet Mn-54 4

0.0030

<LLD ( 0/ 3) ALL <LLD

<LLD ( 0/ 1) 0 keyhole limpet Sr-90 4

0.0200

<LLD ( 0/ 3) ALL <LLD

<LLD 0/ 1) 0

  • 0 Page 139 07JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1, 1980 to December 31, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements Table 12A Non-Migratory Marine Quarterly Composite (pCi/g) (flesh type) keyhole limpet Zn-65 4

0.0070

<LLD ( 0/ 3) ALL <LLD

<LLD ( 0/ 1) 0 keyhole limpet Zr(Nb)-95 4

0.0070

<LLD ( 0/ 3) ALL <LLD

<LLD ( 0/ 1) 0 0.170- 0.170) Unit 1 Outfall

( 0.170- 0.170) 0.9 mi.

WSW sea hare Co-58 4

0.0070 0.0430( 1/ 1) 0.0430( 1/ 1) <LLD ( 0/ 3) 0 0.043- 0.043) Unit 1 Outfall

( 0.043- 0.043) 0.9 mi.

WSW sea hare Co-60 4

0.0050 0.1380( 1/ 1) 0.1380( 1/ 1) 0.0140( 2/ 3) 0 0.138- 0.138) Unit 1 Outfall

( 0.138- 0.138) ( 0.012- 0.016) 0.9 mi.

WSW Table 12A Non-Migratory Marine Quarterly Composite (pCi/g) (flesh type) sea hare Cs-134 4

0.0040

<LLD ( 0/

1) ALL <LLD

<LLD ( 0/

3) 0 sea hare Cs-137 4

0.0010

<LLD ( 0/ 1) ALL <LLD

<LLD C 0/

3) 0 sea hare Fe-59 4

0.0090

<LLD ( 0/ 1) ALL <LLD

<LLD ( 0/

3) 0 sea hare 1-131 4

0.0150

<LLD ( 0/ 1) ALL <LLD

<LLD ( 0/

3) 0 sea hare Mn-54 4

0.0030

<LLD ( 0/

1) ALL <LLD

<LLD ( 0/

3) 0 Table 12A Non-Migratory Marine Quarterly Composite (pCi/g) (flesh type) sea hare Sr-90 4

0.0200

<LLD ( 0/ 1) ALL <LLD

<LLD ( 0/

3) 0 sea hare Zn-65 4

0.0070

<LLD ( 0/ 1) ALL <LLD

<LLD ( 0/

3) 0 sea hare Zr(Nb)-95 4

0.0070

<LLD ( 0/ 1) ALL <LLD

<LLD ( 0/

3) 0 0.020- 0.056) Unit 1 Outfall

( 0.056- 0.056) 0.9 mi.

WSW

Page 140 07JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1, 1980 to December 31, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements Table 12A Non-Migratory Marine Quarterly Composite (pCi/g) (flesh type) sheep crab Co-58 3

0.0070 0.0440( 2/ 3) 0.0730( 1/ 1) <LLD ( 0/ 0) 0 0.015- 0.073) Unit 1 Outfall

( 0.073- 0.073) 0.9 mi.

WSW sheep crab Co-60 3

0.0050 0.0257( 3/ 3) 0.0510( 1/ 1) <LLD ( 0/ 0) 0 0.012- 0.051) Unit 1 Outfall

( 0.051- 0.051) 0.9 mi.

WSW sheep crab Cs-134 3

0.0040

<LLD ( 0/ 3) ALL <LLD

<LLD ( 0/ 0) 0 sheep crab Cs-137 3

0.0010

<LLD (

0/ 3) ALL <LLD

<LLD ( 0/ 0) 0 sheep crab Fe-59 3

0.0090

<LLD (

0/ 3) ALL <LLD

<LLD C 0/ 0) 0 1.000- 7.000) Units 2/3 Outfall ( 1.000- 7.000) 1.5 mi.

SSW Table 12A Non-Migratory Marine Quarterly Composite (pCi/g) (flesh type) sheep crab 1-131 3

0.0150

<LLD ( 0/ 3) ALL <LLD

<LLD ( 0/ 0) 0 sheep crab Mn-54 3

0.0030

<LLD ( 0/ 3) ALL <LLD

<LLD ( 0/ 0) 0 sheep crab Sr-90 3

0.0200

<LLD ( 0/ 3) ALL <LLD

<LLD ( 0/ 0) 0 Table 12A Non-Migratory Marine Quarterly Composite (pCi/g) (flesh type) sheep crab Zn-65 3

0.0070

<LLD ( 0/ 3) ALL <LLD

<LLD ( 0/ 0) 0 sheep crab Zr(Nb)-95 3

0.0070

<LLD ( 0/ 3) ALL <LLD

<LLD (

0/ 0) 0 sheephead Co-58 12 0.0070

<LLD ( 0/ 8) ALL <LLD

<LLD (

0/ 4) 0 sheephead Co-60 12 0.0050

<LLD ( 0/ 8) ALL <LLD

<LLD (

0/ 4) 0 sheephead Cs-134 12 0.0040

<LLD ( 0/ 8) ALL <LLD

<LLD (

0/ 4) 0

Page 141 07JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1, 1980 to December 31, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements Table 12A Non-Migratory Marine Quarterly Composite (pCi/g) (flesh type) sheephead Cs-137 12 0.0010 0.0102( 8/ 8) 0.0115( 4/ 4) 0.0075( 4/ 4) 0 0.004- 0.014) Units 2/3 Outfall ( 0.010- 0.014) ( 0.005- 0.010) 1.5 mi.

SSW sheephead Fe-59 12 0.0090

<LLD (

0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 sheephead H-3 Bound 12 1.4000 27.443( 7/ 8) 44.067( 3/ 4) 44.067( 3/ 4) 0 1.400-88.000) Newport Beach

(.8.200-94.000).(

8.200-94.000) 18.2 mi.

NW sheephead 1-131 12 0.0150

<LLD (

0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 sheephead Mn-54 12 0.0030

<LLD (

0/ 8)

ALL <LLD

<LLD ( 0/ 4) 0 Table 12A Non-Migratory Marine Quarterly Composite (pCi/g) (flesh type) sheephead Sr-90 12 0.0200

<LLD ( 0/

8) ALL <LLD

<LLD ( 0/ 4) 0 sheephead Zn-65 12 0.0070

<LLD ( 0/

8)

ALL <LLD

<LLD ( 0/ 4) 0 sheephead Zr(Nb)-95 12 0.0070

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 spiny lobster Ag-110m 9

0.0030 0.1360( 5/ 5) 0.1850( 2/ 2) 0.0200( 1/ 4) 0 0.048- 0.270) Units 2/3 Outfall ( 0.100- 0.270) ( 0.020- 0.020) 1.5 mi.

SSW

Page 142 07JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1, 1980 to December 31, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements Table 12A Non-Migratory Marine Quarterly Composite (pCi/g) (flesh type) spiny lobster Co-58 9

0.0070 0.0823( 3/ 5) 0.1500( 1/ 2) <LLD ( 0/ 4) 0 0.017- 0.150) Units 2/3 Outfall ( 0.150- 0.150) 1.5 mi.

SSW spiny lobster Co-60 9

0.0050 0.0762( 4/ 5) 0.1215( 2/ 3) <LLD ( 0/ 4) 0 0.018- 0.200) Unit 1 Outfall

( 0.043- 0.200) 0.9 mi.

WSW spiny lobster Cs-134 9

0.0040

<LLD ( 0/ 5) ALL <LLD

<LLD ( 0/ 4) 0 spiny lobster Cs-137 9

0.0010

<LLD ( 0/ 5) 0.0150( 1/ 4) 0.0150( 1/ 4) 0 Newport Beach

( 0.015- 0.015) ( 0.015- 0.015) 18.2 mi.

NW spiny lobster Fe-59 9

0.0090

<LLD ( 0/ 5) ALL <LLD

<LLD ( 0/ 4) 0 spiny lobster H-3 Bound 9

1.4000 26.650( 2/ 5) 51.000( 1/ 4) 51.000( 1/ 4) 0 8.300-45.000) Newport Beach (51.000-51.000) (51.000-51.000) 18.2 mi.

NW spiny lobster 1-131 9

0.0150

<LLD ( 0/ 5) ALL <LLD

<LLD ( 0/ 4) 0

Page 143 07JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1, 1980 to December 31, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements Table 12A Non-Migratory Marine Quarterly Composite (pCi/g) (flesh type) spiny lobster Mn-54 9

0.0030

<LLD ( 0/ 5) ALL <LLD

<LLD ( 0/ 4) 0 spiny lobster Sr-90 9

0.0200

<LLD ( 0/ 5) ALL <LLD

<LLD ( 0/ 4) 0 spiny lobster Zn-65 9

0.0070

<LLD ( 0/ 5) ALL <LLD

<LLD ( 0/ 4) 0 Table 12A Non-Migratory Marine Quarterly Composite (pCi/g) (flesh type) spiny lobster Zr(Nb)-95 9

0.0070

<LLD ( 0/ 5) ALL <LLD

<LLD ( 0/ 4) 0 Table 12B Non-Migratory Marine Quarterly Composite (pCi/g) (bone type) bay mussel Co-58 4

0.0100

<LLD ( 0/ 4) ALL <LLD

<LLD ( 0/ 0) 0 bay mussel Co-60 4

0.0110

<LLD ( 0/ 4) ALL <LLD

<LLD ( 0/

0) 0 bay mussel Cs-134 4

0.0100

<LLD ( 0/ 4) ALL <LLD

<LLD ( 0/ 0) 0 bay mussel Cs-137 4

0.0080

<LLD ( 0/ 4) ALL <LLD

<LLD ( 0/

0) 0 bay mussel Fe-59 4

0.0200

<LLD C 0/ 4) ALL <LLD

<LLD 0/

0) 0 Table 12B Non-Migratory Marine Quarterly Composite (pCi/g) (bone type) bay mussel 1-131 4

0.0400

<LLD ( 0/ 4) ALL <LLD

<LLD ( 0/

0) 0 bay mussel Mn-54 4

0.0080

<LLD ( 0/ 4) ALL <LLD

<LLD ( 0/

0) 0 bay mussel Sr-90 4

0.0120

<LLD ( 0/ 4) ALL <LLD

<LLD ( 0/

0) 0 Table 128 Non-Migratory Marine Quarterly Composite (pCi/g) (bone type) bay mussel Zn-65 4

0.0160

<LLD ( 0/ 4) ALL <LLD

<LLD ( 0/

0) 0 bay mussel Zr(Nb)-95 4

0.0160

<LLD ( 0/ 4) ALL <LLD

<LLD ( 0/

0) 0 black perch Co-58 12 0.0100

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 black perch Co-60 12 0.0110

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 black perch Cs-134 12 0.0100

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0

Page 144 07JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1, 1980 to December 31, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements Table 12B Non-Migratory Marine Quarterly Composite (pCi/g) (bone type) black perch Cs-137 12 0.0080

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 black perch Fe-59 12 0.0200

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 black perch 1-131 12 0.0400

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 black perch Mn-54 12 0.0080

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 Table 12B Non-Migratory Marine Quarterly Composite (pCi/g) (bone type) black perch Sr-90 12 0.0120

<LLD ( 0/ 8) ALL <LLD

<LLD 0/ 4) 0 black perch Zn-65 12 0.0160

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 black perch Zr(Nb)-95 12 0.0160

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 keyhole limpet Co-58 4

0.0100 0.0360( 1/ 3) 0.0360( 1/ 3) <LLD ( 0/

1) 0 0.036- 0.036) Units 2/3 Outfall ( 0.036- 0.036) 1.5 mi.

SSW Table 12B Non-Migratory Marine Quarterly Composite (pCi/g) (bone type) keyhole limpet Co-60 4

0.0110 0.0140( 1/ 3) 0.0140( 1/ 3) <LLD ( 0/ 1) 0 0.014- 0.014) Units 2/3 Outfall ( 0.014- 0.014) 1.5 mi.

SSW keyhole limpet Cs-134 4

0.0100

<LLD ( 0/

3) ALL <LLD

<LLD ( 0/

1) 0 keyhole limpet Cs-137 4

0.0080

<LLD ( 0/

3) ALL <LLD

<LLD ( 0/

1) 0 keyhole limpet Fe-59 4

0.0200

<LLD ( 0/

3) ALL <LLD

<LLD ( 0/

1) 0 keyhole limpet 1-131 4

0.0400

<LLD ( 0/

3) ALL <LLD

<LLD ( 0/

1) 0 keyhole limpet Mn-54 4

0.0080

<LLD ( 0/

3) ALL <LLD

<LLD ( 0/

1) 0

Page 145 07JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1, 1980 to December 31, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements Table 12B Non-Migratory Marine Quarterly Composite (pCi/g) (bone type) keyhole limpet Sr-90 4

0.0120

<LLD ( 0/ 3) ALL <LLD

<LLD ( 0/ 1) 0 keyhole limpet Zn-65 4

0.0160

<LLD ( 0/ 3) ALL <LLD

<LLD ( 0/ 1) 0 keyhole limpet Zr(Nb)-95 4

0.0160

<LLD (

0/ 3) ALL <LLD

<LLD ( 0/ 1) 0 0.030- 0.030) Unit 1 Outfall 0.030- 0.030) 0.9 mi.

WSW

Page 146 07JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1, 1980 to December 31, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements Table 128 Non-Migratory Marine Quarterly Composite (pCi/g) (bone type) sheep crab Co-58 3

0.0100 0.0410( 1/ 3) 0.0410( 1/ 1) <LLD ( 0/ 0) 0 0.041- 0.041) Unit 1 Outfall

( 0.041- 0.041) 0.9 mi.

WSW sheep crab Co-60 3

0.0110 0.0300( 1/ 3) 0.0300( 1/ 1) <LLD ( 0/

0) 0 0.030- 0.030) Unit 1 Outfall

( 0.030- 0.030) 0.9 mi.

WSW sheep crab Cs-134 3

0.0100

<LLD ( 0/ 3) ALL <LLD

<LLD ( 0/ 0) 0 sheep crab Cs-137 3

0.0080

<LLD ( 0/ 3) ALL <LLD

<LLD ( 0/ 0) 0 sheep crab Fe-59 3

0.0200

<LLD (

0/ 3) ALL <LLD

<LLD ( 0/ 0) 0 sheep crab 1-131 3

0.0400

<LLD (

0/ 3) ALL <LLD

<LLD ( 0/ 0) 0 sheep crab Mn-54 3

0.0080

<LLD (

0/ 3) ALL <LLD

<LLD ( 0/ 0) 0 Table 12B Non-Migratory Marine Quarterly Composite (pCi/g) (bone type) sheep crab Sr-90 3

0.0120

<LLD ( 0/

3) ALL <LLD

<LLD ( 0/ 0) 0 sheep crab Zn-65 3

0.0160

<LLD ( 0/

3) ALL <LLD

<LLD ( 0/ 0) 0 sheep crab Zr(Nb)-95 3

0.0160

<LLD ( 0/

3) ALL <LLD

<LLD ( 0/ 0) 0 Table 128 Non-Migratory Marine Quarterly Composite (pCi/g) (bone type) sheephead Co-58 12 0.0100

<LLD ( 0/

8) ALL <LLD

<LLD 0/ 4) 0 sheephead Co-60 12 0.0110

<LLD ( 0/

8) ALL <LLD

<LLD ( 0/ 4) 0 sheephead Cs-134 12 0.0100

<LLD ( 0/

8) ALL <LLD

<LLD C 0/ 4) 0 sheephead Cs-137 12 0.0080

<LLD ( 0/

8) ALL <LLD

<LLD C 0/ 4) 0 sheephead Fe-59 12 0.0200

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 sheephead 1-131 12 0.0400

<LLD ( 0/ 8) ALL <LLD

<LLD C 0/ 4) 0

0 Page 147 07JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1, 1980 to December 31, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements Table 12B Non-Migratory Marine Quarterly Composite (pCi/g) (bone type) sheephead Mn-54 12 0.0080

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 sheephead Sr-90 12 0.0120

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 sheephead Zn-65 12 0.0160

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 Table 12B Non-Migratory Marine Quarterly Composite (pCi/g) (bone type) sheephead Zr(Nb)-95 12 0.0160

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 4) 0 0.040- 0.130) Unit 1 Outfall

( 0.040- 0.130) 0.9 mi..WSW spiny lobster Co-58 9

0.0100 0.0450( 2/ 5) 0.0500( 1/ 3) <LLD ( 0/ 4) 0 0.040- 0.050) Unit 1 Outfall

( 0.050- 0.050) 0.9 mi.

WSW spiny lobster Co-60 9

0.0110 0.0650( 2/ 5) 0.1000( 1/ 3) <LLD ( 0/ 4) 0 0.030- 0.100) Unit 1 Outfall

( 0.100- 0.100) 0.9 mi.

WSW spiny lobster Cs-134 9

0.0100

<LLD (

0/ 5) ALL <LLD

<LLD ( 0/ 4) 0 spiny lobster Cs-137 9

0.0080

<LLD (

0/

5) ALL <LLD

<LLD ( 0/

4) 0 Table 12B Non-Migratory Marine Quarterly Composite (pCi/g) (bone type) spiny lobster Fe-59 9

0.0200

<LLD ( 0/ 5) ALL <LLD

<LLD ( 0/

4) 0 spiny lobster 1-131 9

0.0400

<LLD ( 0/ 5)

ALL <LLD

<LLD ( 0/ 4) 0 spiny lobster Mn-54 9

0.0080

<LLD ( 0/ 5) ALL <LLD

<LLD C 0/ 4) 0 spiny lobster Sr-90 9

0.0120

<LLD ( 0/ 5) ALL <LLD

<LLD 0/ 4) 0 Table 12B Non-Migratory Marine Quarterly Composite (pCi/g) (bone type) spiny lobster Zn-65 9

0.0160

<LLD ( 0/ 5) ALL <LLD

<LLD C 0/ 4) 0 spiny lobster Zr(Nb)-95 9

0.0160

<LLD C 0/ 5) ALL <LLD

<LLD ( 0/ 4) 0

  • 0 Page 148 07JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1, 1980 to December 31, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements Table 13A Local Crops Semi-Annual Composite (pCi/g) corn Co-58 2

0.0010

<LLD ( 0/

1) ALL <LLD

<LLD ( 0/

1) 0 corn Co-60 2

0.0020

<LLD ( 0/ 1) ALL <LLD

<LLD ( 0/

1) 0 corn Cs-134 2

0.0010

<LLD ( 0/ 1) ALL <LLD

<LLD ( 0/ 1) 0 corn Cs-137 2

0.0010

<LLD ( 0/ 1) ALL <LLD

<LLD ( 0/ 1) 0 corn 1-131 2

0.0090

<LLD ( 0/ 1) ALL <LLD

<LLD ( 0/

1) 0 Table 13A Local Crops Semi-Annual Composite (pCi/g) corn Zr(Nb)-95 2

0.0020

<LLD ( 0/ 1) ALL <LLD

<LLD ( 0/

1) 0 tomato Co-58 2

0.0010

<LLD ( 0/ 1) ALL <LLD

<LLD ( 0/

1) 0 tomato Co-60 2

0.0020

<LLD ( 0/ 1) ALL <LLD

<LLD ( 0/

1) 0 Table 13A Local Crops Semi-Annual Composite (pCi/g) tomato Cs-134 2

0.0010

<LLD ( 0/ 1) ALL <LLD

<LLD ( 0/ 1) 0 tomato Cs-137 2

0.0010

<LLD ( 0/

1) ALL <LLD

<LLD ( 0/ 1) 0 tomato 1-131 2

0.0090

<LLD ( 0/

1) ALL <LLD

<LLD ( 0/ 1) 0 tomato Zr(Nb)-95 2

0.0020

<LLD ( 0/

1) ALL <LLD

<LLD ( 0/ 1) 0 Table 13B Local Crops Semi-Annual Composite (pCi/g) corn H-3 Bound 2

0.2540 110.00( 1/ 1) 300.00( 1/ 1) 300.00( 1/ 1) 0 (110.00-110.00) SE of Oceanside (300.00-300.00) (300.00-300.00) 22 mi.

SE corn Sr-90 2

0.0005

<LLD ( 0/

1) ALL <LLD

<LLD (

0/ 1) 0 tomato H-3 Bound 2

0.2540 86.000( 1/ 1) 110.00( 1/ 1) 110.00( 1/ 1) 0 (86.000-86.000) SE of Oceanside (110.00-110.00) (110.00-110.00) 22 mi.

SE tomato Sr-90 2

0.0005

<LLD ( 0/ 1) ALL <LLD

<LLD (

0/ 1) 0

Page 149 07JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1, 1980 to December 31. 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements Table 14 Soil Samples Annual Composite (pCi/g)

Co-58 5

0.0100

<LLD ( 0/ 4) ALL <LLD

<LLD ( 0/ 1) 0 Co-60 5

0.0110

<LLD ( 0/ 4) ALL <LLD

<LLD ( 0/ 1) 0 Cs-134 5

0.0090

<LLD ( 0/ 4) ALL <LLD

<LLD ( 0/ 1) 0 Cs-137 5

0.0070 0.0400( 2/ 4) Huntington Beach 0.0600( 1/ 1) 0.0600( 1/ 1) 0 0.020- 0.060) Generating Station ( 0.060- 0.060) ( 0.060- 0.060) 37 mi.

NW 1-131 5

0.0210

<LLD ( 0/ 4) ALL <LLD

<LLD (

0/ 1) 0 Table 14 Soil Samples Annual Composite (pCi/g)

Sr-89 5

0.0070

<LLD ( 0/ 4) ALL <LLD

<LLD (

0/ 1) 0 Sr-90 5

0.0070 0.0350( 2/ 4) Camp San Onofre 0.0500( 1/ 1) 0.0300( 1/ 1) 0 0.020- 0.050) Camp Pen.

( 0.050- 0.050) ( 0.030- 0.030) 2.5 mi.

NE Zr(Nb)-95 5

0.0150

<LLD ( 0/ 4) ALL <LLD

<LLD (

0/ 1) 0 Table 15 Kelp Semi-Annual Composite (pCi/g) macrocystis p.

Co-58 8

0.0090

<LLD ( 0/ 6) ALL <LLD

<LLD ( 0/ 2) 0 macrocystis p.

Co-60 8

0.0100

<LLD ( 0/ 6) ALL <LLD

<LLD ( 0/ 2) 0 macrocystis p.

Cs-134 8

0.0080

<LLD ( 0/ 6)

ALL <LLD

<LLD ( 0/ 2) 0 macrocystis p. Cs-137 8

0.0060

<LLD ( 0/ 6)

ALL <LLD

<LLD ( 0/ 2) 0 macrocystis p.

Fe-59 8

0.0180

<LLD ( 0/ 6)

ALL <LLD

<LLD ( 0/ 2) 0

Page 150 07JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1, 1980 to December 31, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements Table 15 Kelp Semi-Annual Composite (pCi/g) 1.600- 1.600) Kelp Bed

( 1.600- 1.600) 3.8 mi.

WNW macrocystis p.

1-131 8

0.0200 0.0132( 4/ 6) San Onofre 0.0240( 1/ 2) 0.0085( 2/ 2) 0 0.006- 0.024) Kelp Bed

( 0.024- 0.024) ( 0.008- 0.009) 1.5 mi.

SSW macrocystis p. Mn-54 8

0.0070

<LLD ( 0/ 6) ALL <LLD

<LLD ( 0/ 2) 0

Page 151 07JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1, 1980 to December 31, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements Table 15 Kelp Semi-Annual Composite (pCi/g) macrocystis p. Zn-65 8

0.0140

<LLD (

0/ 6) ALL <LLD

<LLD (

0/ 2) 0 macrocystis p. Zr(Nb)-95 8

0.0140 0.0190( 3/ 6) San Onofre 0.0230( 1/ 2) 0.0180( 1/ 2) 0 0.014- 0.023) Kelp Bed

( 0.023- 0.023) ( 0.018- 0.018) 1.5 mi.

SSW