ML13317B660
| ML13317B660 | |
| Person / Time | |
|---|---|
| Site: | San Onofre |
| Issue date: | 12/31/1972 |
| From: | Southern California Edison Co |
| To: | |
| Shared Package | |
| ML13317B650 | List: |
| References | |
| NUDOCS 9108120280 | |
| Download: ML13317B660 (6) | |
Text
Page 21 n (
05JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM
SUMMARY
Docket Nos. 50-206, 50-361, 50-362 D>b3 Reporting period: January 1, 1972 to December 31, 1972 C f-0Type and Lower Limit All Indicator Location with Number of
')D Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)
Name, Distance Mean(f)
Mean(f)
Reported C 0 of Measurement)
Performed (LLD)
Range and Direction Range Range Measurements Table 2
.C)C-Airborne 3
Weekly Composite Gross Beta 380 0.0011 0.1008( 61/342) Camp San Onofre 0.1158( 31/ 38) <LLD ( 0/ 38) 0
( 0.010- 0.830) Camp Pen.
( 0.020- 0.830) 1.8 mi.
NE Table 4A Airborne Quarterly Composite (PCi/cu.m)
Co-58 4
0.0010
<LLD ( 0/ 4) ALL <LLD
<LLD ( 0/ 0) 0 Co-60 4
0.0010
<LLD ( 0/ 4) ALL <LLD
<LLD ( 0/ 0) 0 Cs-134 4
0.0010
<LLD ( 0/ 4) ALL <LLD
<LLD ( 0/ 0) 0 Cs-137 4
0.0010
<LLD ( 0/ 4) ALL <LLD
<LLD ( 0/ 0) 0 Table 4A Airborne Quarterly Composite (pCi/cu.m)
Zr(Nb)-95 4
0.0010 0.0195( 4/ 4) Camp San Onofre 0.0200( 2/ 2) <LLD ( 0/ 0) 0 0.010- 0.030) Camp Pen.
( 0.010- 0.030) 1.8 mi.
NE Table 4C Airborne Quarterly Composite (pCi/cu.m)
Gross Alpha 44 0.0003 0.0020( 7/ 40) Camp San Onofre 0.0025( 4/ 4) <LLD ( 0/ 4) 0
( 0.000- 0.006) Camp Pen.
( 0.001- 0.006) 1.8 mi.
NE Sr-90 44 0.0030
<LLD ( 0/ 40) ALL <LLD
<LLD ( 0/ 4) 0
Page 22 05JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM
SUMMARY
Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1, 1972 to December 31, 1972 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)
Name, Distance Mean(f)
Mean(f)
Reported of Measurement)
Performed (LLD)
Range and Direction Range Range Measurements Table 9d Drinking Water Quarterly Composite (pCi/1)
Gross Alpha 12
<LLD ( 0/ 12) ALL <LLD
<LLD ( 0/ 0) 0 Gross Beta 12 1.2857( 7/ 12) Tri-Cities Munic.
1.6000( 3/ 4) <LLD (
0/ 0) 0 0.600- 2.400) Water Dist. Res.
( 0.800- 2.400) 8.7 mi.
NW Table 9e Drinking Water Quarterly Composite (pCi/1)
Ba(La)-140 7
<LLD ( 0/ 7)
ALL <LLD
<LLD 0/ 0) 0 Co-58 7
<LLD ( 0/ 7)
ALL <LLD
<LLD ( 0/ 0) 0 Co-60 7
<LLD ( 0/
- 7) ALL <LLD
<LLD ( 0/
- 0) 0 Cs-134 7
<LLD ( 0/ 7) ALL <LLD
<LLD ( 0/
- 0) 0 Cs-137 7
<LLD ( 0/ 7) ALL <LLD
<LLD ( 0/
- 0) 0 Table 9e Drinking Water Quarterly Composite (pCi/1)
Fe-59 7
<LLD ( 0/ 7) ALL <LLD
<LLD ( 0/ 0) 0 Gross Alpha 7
11.000( 1/ 7) San Clemente 11.000( 1/ 4) <LLD ( 0/ 0) 0 (11.000-11.000) Golf Course Well (11.000-11.000) 3.5 mi.
NNW Gross Beta 7
23.429( 7/ 7) Tri-Cities Munic. 24.000( 3/ 3) <LLD ( 0/ 0) 0 (20.000-29.000) Water Dist. Res.
(22.000-27.000) 8.7 mi.
NW H-3 7
833.33( 3/ 7) Tri-Cities Munic. 900.00( 1/ 3) <LLD ( 0/ 0) 0 (400.00-1200.0) Water Dist. Res.
(900.00-900.00) 8.7 mi.
NW 1-131 7
<LLD ( 0/ 7) ALL <LLD
<LLD ( 0/ 0) 0 Mn-54 7
<LLD 0/
- 7) ALL <LLD
<LLD 0/
- 0) 0 Zn-65 7
<LLD ( 0/ 7) ALL <LLD
<LLD ( 0/
- 0) 0
Page 23 05JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM
SUMMARY
Docket Nos. 50-206, 50-361. 50-362 Reporting period: January 1, 1972 to December 31, 1972 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)
Name, Distance Mean(f)
Mean(f)
Reported of Measurement)
Performed (LLD)
Range and Direction Range Range Measurements Table 9e Drinking Water Quarterly Composite (pCi/1)
Zr(Nb)-95 7
<LLD (
0/ 7) ALL <LLD
<LLD ( 0/ 0) 0 Table 12a Non-Migratory Marine Quarterly Composite (pCi/g) 0.029- 0.680) Unit 1 Outfall
( 0.029- 0.680) 0.9 mi.
WSW Co-58 4
<LLD (
0/ 4) ALL <LLD
<LLD ( 0/ 0) 0 Co-60 4
0.0120( 1/ 4) 0.0120( 1/ 4) <LLD ( 0/ 0) 0 0.012- 0.012)
Unit 1 Outfall
( 0.012- 0.012) 0.9 mi.
WSW Cs-134 4
0.0130( 1/ 4) 0.0130( 1/ 4) <LLD ( 0/ 0) 0 0.013- 0.013)
Unit 1 Outfall
( 0.013- 0.013) 0.9 mi.
WSW Cs-137 4
0.0480( 1/ 4) 0.0480( 1/ 4) <LLD ( 0/ 0) 0 0.048- 0.048) Unit 1 Outfall
( 0.048- 0.048) 0.9 mi.
WSW Fe-59 4
<LLD ( 0/ 4) ALL <LLD
<LLD ( 0/ 0) 0 Table 12a Non-Migratory Marine Quarterly Composite (pCi/g) 3.200-61.300) Unit 1 Outfall
( 3.200-61.300) 0.9 mi.
WSW 1-131 4
<LLD ( 0/ 4) ALL <LLD
<LLD ( 0/ 0) 0 1.000- 3.530) Unit 1 Outfall
( 1.000- 3.530) 0.9 mi.
WSW Mn-54 4
<LLD ( 0/ 4) ALL <LLD
<LLD ( 0/ 0) 0
- 0 Page 24 05JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM
SUMMARY
Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1, 1972 to December 31, 1972 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)
Name, Distance Mean(f)
Mean(f),
Reported of Measurement)
Performed (LLD)
Range and Direction Range Range Measurements Table 12a Non-Migratory Marine Quarterly Composite (pCi/g)
Sr-90 4
<LLD ( 0/ 4) ALL <LLD
<LLD ( 0/ 0) 0 Zn-65 4
<LLD ( 0/ 4) ALL <LLD
<LLD ( 0/ 0) 0 Zr(Nb)-95 4
<LLD ( 0/ 4) ALL <LLD
<LLD ( 0/ 0) 0 Table 13B LOCAL CROPS Semi-Annual Composite (pCi/g)
(12.000-14.000) San Mateo Canyon (12.000-14.000) 2.6 mi.
NW cabbage Sr-90 2
0.0005
<LLD ( 0/ 2) ALL <LLD
<LLD ( 0/ 0) 0 (22.000-22.000) San Mateo Canyon (22.000-22.000) 2.6 mi.
NW cauliflower Sr-90 1
0.0005
<LLD ( 0/ 1) ALL <LLD
<LLD C 0/ 0) 0 celery Sr-90 1
0.0005
<LLD ( 0/ 1) ALL <LLD
<LLD ( 0/ 0) 0 Table 13B LOCAL CROPS Semi-Annual Composite (pCi/g)
(19.000-19.000) San Mateo Canyon (19.000-19.000) 2.6 mi.
NW cucumber Sr-90 2
0.0005
<LLD ( 0/ 2) ALL <LLD
<LLD ( 0/ 0) 0 (16.000-27.000) San Mateo Canyon (16.000-27.000) 2.6 mi.
NW tomato Sr-90 3
0.0005
<LLD (
0/ 3) ALL <LLD
<LLD ( 0/ 0) 0 Table 15 Kelp Semi-Annual Composite (pCi/g) macrocystis p.
Ce-144 2
0.0250 0.0147( 1/ 1) San Onofre 0.0147( 1/ 1) 0.0119( 1/ 1) 0 0.015- 0.015) Kelp Bed C
0.015- 0.015) ( 0.012- 0.012) 1.5 mi.
SSW macrocystis p.
Co-58 2
0.0090
<LLD ( 0/ 1) ALL <LLD
<LLD C 0/ 1) 0 macrocystis p.
Co-60 2
0.0100
<LLD ( 0/ 1) ALL <LLD
<LLD C 0/ 1) 0 macrocystis p.
Cs-134 2
0.0080
<LLD (
0/ 1) ALL <LLD
<LLD ( 0/ 1) 0
Page 25 05JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM
SUMMARY
Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1, 1972 to December 31, 1972 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)
Name, Distance Mean(f)
Mean(f)
Reported of Measurement)
Performed (LLD)
Range and Direction Range Range Measurements macrocystis p. Cs-137 2
0.0060 0.0078( 1/ 1) San Onofre 0.0078( 1/ 1) 0.0059( 1/ 1) 0 0.008- 0.008) Kelp Bed
( 0.008- 0.008) ( 0.006- 0.006) 1.5 mi.
SSW macrocystis p.
Fe-59 2
0.0180
<LLD (
0/ 1) ALL <LLD
<LLD (
0/ 1) 0
Page 26 05JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM
SUMMARY
Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1, 1972 to December 31, 1972 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)
Name, Distance Mean(f)
Mean(f)
Reported of Measurement)
Performed (LLD)
Range and Direction Range Range Measurements Table 15 Kelp Semi-Annual Composite (pCi/g) macrocystis p.
1-131 2
0.0200
<LLD ( 0/ 1) ALL <LLD
<LLD ( 0/ 1) 0 macrocystis p. K-40 2
0.0770 1.5700( 1/ 1) 2.2800( 1/ 1) 2.2800( 1/ 1) 0 1.570- 1.570) Newport Beach
( 2.280- 2.280) ( 2.280- 2.280) 15.6 mi.
NW macrocystis p. Mn-54 2
0.0070
<LLD ( 0/ 1) ALL <LLD
<LLD ( 0/ 1) 0 Table 15 Kelp Semi-Annual Composite (PCi/g) macrocystis p. Zn-65 2
0.0140
<LLD ( 0/ 1) ALL <LLD
<LLD ( 0/ 1) 0 macrocystis p. Zr(Nb)-95 2
0.0140
<LLD ( 0/ 1) 0.0297( 1/ 1) 0.0297( 1/ 1) 0 Newport Beach
( 0.030- 0.030) ( 0.030- 0.030) 15.6 mi.
NW