n- _U'Z Page 6

n0 03JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Docket Nos. 50-206, 50-361, 50-362 1>*.

Reporting period: January 1, 1969 to December 31, 1969 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements OO CI*C0 Table 2 Airborne Xj C.

Weekly Composite (pCi/cu.m)

Gross Beta 1,060 0.0011 0.2166(189/954) San Clemente City 0.2275( 88/106) <LLD ( 0/106) 0 0.040- 0.960) SDG&E Offices

( 0.060- 0.960) 5.5 mi.

NW Table 4A Airborne Quarterly Composite (pCi/cu.m)

Co-58 3

0.0010

<LLD ( 0/ 3) ALL <LLD

<LLD ( 0/ 0) 0 Co-60 3

0.0010

<LLD ( 0/ 3) ALL <LLD

<LLD ( 0/ 0) 0 Cs-134 3

0.0010

<LLD ( 0/ 3) ALL <LLD

<LLD ( 0/ 0) 0 Cs-137 3

0.0010

<LLD ( 0/ 3) ALL <LLD

<LLD C 0/

0) 0 Table 4A Airborne Quarterly Composite (pCi/cu.m)

Zr(Nb)-95 3

0.0010 0.0520( 3/ 3) Camp San Onofre 0.0580( 2/ 2) <LLD ( 0/ 0) 0 0.040- 0.076) Camp Pen.

C 0.040- 0.076) 1.8 mi.

NE Table 4C Airborne Quarterly Composite (pCi/cu.m)

Gross Alpha 11 0.0003

<LLD ( 0/ 10) ALL <LLD

<LLD ( 0/ 1) 0 Sr-90 11 0.0030

<LLD ( 0/ 10) ALL <LLD

<LLD ( 0/ 1) 0

Page 7 03JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1. 1969 to December 31, 1969 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements Table 9d Drinking Water Quarterly Composite (pCi/1)

Gross Alpha 15

<LLD ( 0/ 15) ALL <LLD

<LLD ( 0/ 0) 0 Gross Beta 15 3.1889( 9/ 15)

San Clemente 4.1600( 5/ 5) <LLD ( 0/ 0) 0 0.900-16.400) Golf Course Well

( 0.900-16.400) 3.5 mi.

NNW Table 9e Drinking Water Quarterly Composite (pCi/1)

Ba(La)-140 8

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 0) 0 Co-58 8

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 0) 0 Co-60 8

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 0) 0 Cs-134 8

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 0) 0 Cs-137 8

<LLD ( 0/ 8) ALL <LLD

<LLD C 0/ 0) 0 Table 9e Drinking Water Quarterly Composite (pCi/1)

Fe-59 8

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 0) 0 Gross Alpha 8

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 0) 0 Gross Beta 8

27.750( 8/ 8) San Clemente 28.250( 4/ 4) <LLD ( 0/ 0) 0 (21.000-34.000) Golf Course Well (22.000-34.000) 3.5 mi.

NNW H-3 8

1900.0( 2/ 8) San Clemente 2000.0( 1/ 4) <LLD ( 0/ 0) 0 (1800.0-2000.0) Golf Course Well (2000.0-2000.0) 3.5 mi.

NNW 1-131 8

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 0) 0 Mn-54 8

<LLD 0/

8) ALL <LLD

<LLD (0/

0) 0 Zn-65 8

<LLD

( 0/ 8) ALL <LLD

<LLD ( 0/ 0) 0

Page 8 03JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1, 1969 to December 31, 1969 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements Table 9e Drinking Water Quarterly Composite (pCi/1)

Zr(Nb)-95 8

<LLD ( 0/ 8) ALL <LLD

<LLD ( 0/ 0) 0