Enclosure 2
- n q3 Page 1 03JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM
SUMMARY
0 Docket Nos. 50-206. 50-361. 50-362 Reporting period: January 1, 1967 to December 31, 1967 Type and Lower Limit All Indicator Location with Number of 0
Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)
Name, Distance Mean(f)
Mean(f)
Reported 0
of Measurement)
Performed (LLD)
Range and Direction Range Range Measurements Table 2 Airborne Weekly Composite (pCi/cu.m)
Kc m 2Gross Beta 1,070 0.0011 0.2003(179/963) San Clemente City 0.2653(100/107) 0.2326( 99/107) 0 0.040- 3.810) SDG&E Offices
( 0.040- 3.810) ( 0.040- 1.940) 5.5 mi.
NW Table 4A Airborne Quarterly Composite (pCi/cu.m)
Co-58 2
0.0010
<LLD ( 0/ 1) ALL <LLD
<LLD ( 0/ 1) 0 Co-60 2
0.0010
<LLD ( 0/ 1) ALL <LLD
<LLD ( 0/ 1) 0 Cs-134 2
0.0010
<LLD ( 0/ 1) ALL <LLD
<LLD ( 0/ 1) 0 Cs-137 2
0.0010
<LLD ( 0/ 1) ALL <LLD
<LLD ( 0/ 1) 0 Table 4A Airborne Quarterly Composite (pCi/cu.m)
Zr(Nb)-95 2
0.0010 0.0090( 1/ 1) Huntington Beach 0.0220( 1/ 1) 0.0220( 1/ 1) 0 0.009- 0.009) Generating Station ( 0.022- 0.022) ( 0.022- 0.022) 37 mi.
NW Table 9C Drinking Water Monthly Composite (pCi/1)
Gross Alpha 6
0.4430
<LLD (
0/ 4) ALL <LLD
<LLD 0/ 2) 0 Gross Beta 6
1.4750 20.850( 4/ 4) Tri-Cities Munic.
24.250( 2/ 2) <LID ( 0/ 2) 0 (15.300-29.700) Water Dist. Res.
(18.800-29.700) 8.7 mi.
NW
Page 2 03JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM
SUMMARY
Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1, 1967 to December 31, 1967 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)
Name, Distance Mean(f)
Mean(f)
Reported of Measurement)
Performed (LLD)
Range and Direction Range Range Measurements Table 9D Drinking Water Quarterly Composite (pCi/1)
Gross Alpha 18 0.2110
<LLD (
0/ 12)
ALL <LLD
<LLD ( 0/ 6) 0 Gross Beta 18 0.7380 1.3683( 12/ 12)
Tri-Cities Munic. 2.0767( 6/ 6) <LLD ( 0/ 6) 0 0.330- 4.100) Water Dist. Res.
( 0.880- 4.100) 8.7 mi.
NW Table 9E Drinking Water Quarterly Composite (pCi/1)
Ba(La)-140 8
37.400
<LLD ( 0/
- 8) ALL <LLD
<LLD ( 0/
- 0) 0 Co-58 8
5.1000
<LLD ( 0/ 8) ALL <LLD
<LLD C 0/ 0) 0 Co-60 8
5.4000
<LLD ( 0/ 8) ALL <LLD
<LLD ( 0/ 0) 0 Cs-134 8
4.6000
<LLD ( 0/ 8) ALL <LLD
<LLD ( 0/ 0) 0 Cs-137 8
3.7000
<LLD ( 0/ 8) ALL <LLD
<LLD ( 0/ 0) 0 Table 9E Drinking Water Quarterly Composite (pCi/1)
Fe-59 8
9.5000
<LLD ( 0/ 8) ALL <LLD
<LLD ( 0/ 0) 0 Gross Alpha 8
0.6320
<LLD ( 0/ 8) ALL <LLD
<LLD C 0/ 0) 0 Gross Beta 8
0.6990 19.587( 8/ 8) Tri-Cities Munic.- 22.625( 4/ 4) <LLD C 0/ 0) 0 5.300-29.700) Water Dist. Res.
(18.800-29.700) 8.7 mi.
NW H-3 8
102.00
<LLD ( 0/ 8) ALL <LLD
<LLD ( 0/ 0) 0 1-131 8
0.5100
<LLD ( 0/ 8) ALL <LLD
<LLD ( 0/ 0) 0 Mn-54 8
3.7000
<LLD ( 0/ 8) ALL <LLD
<LLD ( 0/ 0) 0 Zn-65 8
7.7000
<LLD ( 0/ 8) ALL <LLD
<LLD ( 0/ 0) 0
0 Page 3 03JUL91 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM
SUMMARY
Docket Nos. 50-206, 50-361, 50-362 Reporting period: January 1. 1967 to December 31, 1967 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)
Name, Distance Mean(f)
Mean(f)
Reported of Measurement)
Performed (LLD)
Range and Direction Range Range Measurements Table 9E Drinking Water Quarterly Composite (pCi/1)
Zr(Nb)-95 8
7.7000
<LLD ( 0/ 8) ALL <LLD
<LLD ( 0/ 0) 0