Southern California Edison Company

,gCE P.O. Box 8O 2244 WALNUT GROVE AVENUE q

ROSEMEAD. CALIFORNIA 91770 September 29, 1981 633 Dr. Tien-Yuh Chuang Lawrence Livermore National Laboratory P.O. Box 808 Livermore, California 94550 Gentlemen:

Subject:

Auxiliary Feedwater System Project San Onofre Nuclear Generating Station Unit 1

Reference:

Telephone discussion with Mr. G. J. Stawniczy dated September 23, 1981 This letter confirms information transmitted to you by Mr.

Stawniczy in the course of your telephone discussion of September 23.

1) Support 381-A-Gl-15; per drawing no. 518062-3, detail 14, this support is a biaxial guide (G-2),

and does not restrict motion along the axis of the pipe.

2)

The dimension between nodes 48 and 49, on the stress isometric for line no. 69-3"-EG is 2 ft. 10 in.

3)

The tie-in point for-'line 69-3"-EG, as shown in the enclosed isometric

sketch, at node' 1, is shown marked up on drawing no.

450339-0, also enclosed.

The distance between the anchor and the first elbow downstream is 2 ft. 5 1/4 in.

4) For the 14" expansion joint on line 721-14"-EG, the spring constant to be used for stress calculation is 1650 lbs. per inch compression and 825 lbs.

per inch tension.

This joint is a 14" garlock rubber expansion joint which has different spring rates in tension and compression.

S 81902701c~v(

/*

PDR ADOCK 05!00!02~

L4ML6

Dr. Tien-Yuh Chuang September 29, 1981 If you have any questions concerning the above information, please call Mr. Stawniczy directly, at (213) 572-3675.

Sincerely, R. C. Blaschke Project Engineer cc: C. Burger (NRC)

K. Herring (NRC)

S. Nowicki (NRC)

P. D. Smith (LLL)