REGULATORY I FORMATION-DISTRIBUTION SYSTEM (RIDS)

ACCESSION NR:8110280129-DOC.DATE: 81/10/19 NOTARIZED: NO 90CKEWT #

FACILf:50-206 San Onofre Nuclear Station, Unit 1,. Southern, Californ 05000206 AUTHINAMEJ AUTHOR AFFILIATION BLASCHKE,-R.C.

Southern California Edison Co.

RECIP.JAMPi REC1PIENT AFFILIATION CHUANGrT!,Y.

Lawrence Li'vermore Laboratory

SUBJECT:

Forwards adil info required forzanalysis of auxiliary feedwater pipingsysoperiS10928 1tr. ain stop:valve for turbine supplied, by WestinghouseList of unavaailaolelinifo emd,

DISTRIBUTION CODEi:

AD0DIS COPIES RECEilVEO:LUTR ENC; j SIZE:-I TITLE: Seneral Distribution fori after Issuance of Operating, License NOTES:1 cy eacni:SEP Section Leader & J Wanchett (Region V) 05000206 REC'I IENT1 COPIES RECIPIENT COPITES 10' CODE/NAMEi LTTR ENCLU 10 CODEVNAME:

LTTRI ENCLU ACTION:-

OR3 #5 BC 01 13 13 INTERNAL;:

ELt) 1 0

I&E 06 2

2 NRR/DHFS DEPY05 1

1

,NRR/DL DIR 1

14 SS BR 1

0 RAD ASMT BR 1

1 RES. FIL O'

1 1

EXTERNAL;:

ACRS 09 16 16 LPDR 03 1

1 NRC PDR 02' 1

1

NSIC, 05 1

1 NTIS 1

1 PRb TOTAL NUA48E!R OF COPIES' REQUIRED;. L'TTR ENCL

Southern California Ediso Company P.O. BOX 800 2244 WALNUT GROVE AVENUE ROSEMEAD.

CALIFORNIA 91770 October 19, 1981 SCE/LLL-18

? JU Dr. Tien-Yuh Chuang U0)\\)j Lawrence Livermore National Laboratory U,

J AII i

P.O. Box 808 Livermore, California 94550 Gentlemen:

Subject:

Information Request, Auxiliary Feedwater Piping Systems San Onofre Nuclear Generating Station Unit 1 Per your letter dated September 28,

1981, I have enclosed (as listed in Attachment I) the majority of additional information required for your analysis.

Unfortunately, some of the information you requested is not available and,' therefore, will not be provided.

The information not provided is also listed in Attachment I.

Isometrics for the line numbers specified in items la, 1b, 1c, id, and 5 of your letter are provided when they are available. I have enclosed the related plan and section drawings from which isometrics can be developed if isometrics are not available.

In regards to Items 2 and 5 of your letter, the most efficient way to obtain the information you have requested, is for you to contact the suppliers directly.

The enclosed valve numbers should aid you in obtaining the desired descriptions.

The main stop val'e for the turbine is supplied by Westinghouse.

Finally, in reference to your question in Item 4, we confirm that those lines are supported.

If you have any questions on any of this information, please let me know.

Sincerely, O(

R. C. Blaschke Project Engineer Enelosures cc:

(w/Attachment 1)

C. Burger (NRC)

K. Herring (NRC)

S. Nowicki (NRC)

P. D. Smith (LLL)

REQUESTED SOURCE OF INFORMATION INFORMATION K

INFORMATION REQUEST PROVIDED NOT PROVIDED Piping Stress Isometrics Item I (a)

Steam line 2-214"-EG Steam System Line Numbers (i)

Isometrics 334530 (ii) 334531 Steam Line from Stop Valve to Turbine Westinghouse Drawing Isometrics 671-J-410 Sht. 1 to 7 Plan & Section 568588 568586 Item I'(b)

Discharge Branch Piping (i)

Line 381-3" Isometric 5180592 334758 334754 Plan & Section 568631 5161062 (ii)

Line 397-3" Isometric 5180592 714060 334753 Plan Section 568631 Item I (c) i Condensate Storage Supply Isometric 334763 Plan & Section 568631 568632 568634 568630 Item I (d) i Fire Protection System Plan & Section 568692 568694 568644 567774

REQUESTED SOURCE OF INFORMATION INFORMATION INFORMATION REQUEST PROVIDED NOT PROVIDED Valve Dimension, Weight II M-18669 Master Valve List Stop Valve Yoke Length and Operator Sheet Numbers 10, 13, 20, 48 (Information not Weight

& 70 available)

M-18690 Control Valve Data Sheets CV-13, CV-113, CV-77 CV-79, RV-1, RV-3, & RV-9 Pipe Schedule III (a)

M-28041 Line Designation List Sheets 19 of 34, 20 of 34, 12 of 17, 24 of 34, 16 of 17 7 of 14, & 28 of 30 III (b)

M-028041 Line Designation List Sheets 1 of 14, 2 of 14, 9 of 14, 2 of 14, 9 of 14, & 12 of 15 Relief Valve Information V

Plan & Section Drawing 568589 Isometric Line Designation List (Not available)

Sheets 10 of 15, 11 of 15 M-18690 Control Valve Data Sheets RV-1-RV-9, CV-76 thru CV-79 KEvans:npe