501-1.2-1.12 POST LOCA COOLDOWN AND REV 0 DEPRESS URI ZATI ON STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTANE EMERGENCY INSTRUCTION SO-1l.2-1.12 POST LOCA COOLDOWN AND DEPRESSURIZATION I.

PURPOSE:

The purpose of this instruction is to bring the reactor coolant system temperature and pressure to or below 350 OF and 400 psig and attempt to restore pressurizer level following a Loss Of Reactor Coolant.

8205240462 820520 PDR ADOCK 05000206 PDR I of 10

501-1.2-1.12 POST LOCA COLDOWN AND REV 0 DEPRESSURIZATION 0

TEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE:

Foldout page should be open.

CAUTION If core exit TCs exceed 1200 OF or RCS hot leg temperatures exceed 700 OF, then go to SOI-1.2-14, RESPONSE TO IMADEQUATE CORE COOL IG.

CAUTION If RWST level reaches 21% or containment level greater than MINUS 3 FT, align SI system for cold leg injection per S01-1.2-1.13, TRANSFER TO COLD LEG INJECTION AND RECIRCULATION.

Compare RCS And Steam Header Pressure:

a. RCS pressure - GREATER
a. IF RCS pressure less TRAN OR EQUAL TO STEAM Than steam header HEADEr7PRESSURE.

pressure, THEN go to SO1-1.2-1.TTOSS OF REACTOR COOLANT, step

11.

2 of 10

DEPRESSURI ZATION

. SEACTION/EXPECTED RESPONSE ESPONSE NOT OBTAINE CAUTION If offsite powr is lost after SI is reset, manual SI initiation will be necessary to load safeguard equipment onto the diesel powered 4 KV busses.

2 Reset SI:

a. Reset SI at SLSS Surveillance Panels.
b. Verify lockout switches
b. Reset lockout.

RESET.

switches.

3 Establish Maximum Charging:

a. Reset non-running charging pump lockout.
b. Start second charcing punp.

3 of 10

501-1.2-1.12 POST LOCA COOLDOWN AND REV 0 DEPRESSURIZATION STEP ACTION/EXPECTED RESPONSE 1-RESPONSE NOT OBTAINED CAUTION Do not exceed total charging pump flow of 330 GPM to avoid potential damage to charging pumps.

4 Establish Charcing Flow Through SI Cod Leg Injecton Lines:

a. Align cold leg injection flow path:

MOV 356 - OPEN.

MOV 357 -

OPEN; MOV 358 -

OPEN.

MOV 18 -

OPEN.

MOV l9 -

OPEN.

b. Isolate normal charging f9ow path:

FCV 1112 -

CLOSED.

CV 304 -

CLOSED.

c. Place seal supply flow controllers, FC 1115 A, B AND C, on MANUAL AND adjust controller to estlETish 200 gpm to each loop with two pumfps running.

5 Check If Feed Pumps Can be Stopped:

a. RCS pressure -

INCREASES

a. IF RCS pressure does BY 200 PSI.

WEt increase by 200 psi, THEN do not stop feed pumps.

b. Stop feed pumps.

4 of 10

S01-1.2-1.12 POST LOCA COOLDOWN AND REV 0 DEPRESSURIZATION STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 6

Initiate RCS Cooldown To 350 OF:

a. Dump steam to condenser OR
1) Place steam dump controller PC 418 A on MANUAL CONTROL.
2) Place steam dump mode selector to - PRESSURE CONTROL ATMOS - CONDENSER.
3) Adjust drnping rate as necessary to maintain cooldown rate less than 50 OF/hr.
b. Maintain SG narrow range levels at approximately 500 during cooldown.

5 of 10

501-1.2-1.12 POST LOCA COOLDOWN AND REV 0 DEPRESSURIZATION ACTION/EXPECTED RESPONSE NOT OBTAINED 7

Check If Pressurizer Level can Be Re-established:

a. RCS pressure - AT LEAST
a. Go to step 11 until 300 PSIG GREATER THAN RCS pressure is STEAM HEADER PRESSURE.

300 psi greater than steam header pressure, THEN go to step 7b.

b. Re-establish pressu'rizer level:
1) Open one PORV.
2) WHEN pressurizer level
2) IF PORV cannot be is greater than 50%,

THEN

ETosed, THEN close close PORV.

its block valve.

c. Energize pressurizer heaters as necessary to increase pressurizer temperature 50 OF above core exit TCs.
1) Maintain pressurizer temperature greater than 50 OF above core exit TCs.

6 of 10

501-1.2-1.12 POST LOCA COOLDOWN AND REY 0 DEPRESSURIZATION

. STP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 8

Check Containment Pressure:

a. Containment pressure - LESS
a. IF high, THEN depress THAN 1.4 PSIG.

override ulibuttons for valves needed open as containment systems are placed inservice.

Go to step 9.

b. Depress Train A AND B containment isolation pushbutton.

9 Check RCP Cooling:

a. RCP low CCW flow alarms
a. Manually adjust CCW RESET.

flow.

b. Verify RCP seal injection
b. Establish seal water.

flow established -

RCP THERMAL Place flow controilers BARRIER DELTA PRESSURES in AUTO set to POSITIVE.

maintain a positive delta pressure.

c. Open RCP seal return CV 527 AND CV 528.
d. Verify seal leakoff is
d. Place PCV 1115 A, B LESS THAN 4.5 GPM.

AND C in AUTO.

7 of 10

DEPRESSURIZATION STEP ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED CAUTI ON I RCPs must be tripped IF RCS pressure decreases to less than 300 psi above stiln header pressure.

10 Check If RCP Can Be Started:

a. RCS pressure - AT LEAST
a. Go to step 11 until 300 PSI GREATER THAN RCS pressure 300 psi STEAM HEADER PRESSURE.

creater than stea header pressure.

b. Pressurizer level - GREATER
b. Go to step 11 until THAN 50.

pressurizer level greater than 50%.

c. Start RCP A OR B per SO-4-3, REATOR COOLANT PUMP OPERATION.

11 Check RCS Temperature:

a. RCS temperature
a. IF RCS temperature is APPROXIMATELY 350 OF.

greater than 350 OF, THEN return to step E.

12 Check RCS Pressure:

a. RCS pressure - GREATER
a. IF pressure less than THAN 400 PSIG.

% PSIG, THEN go to step 15.

8 of 10

501-1.2-1.12 POST LOCA COOLDOW-N AND REV 0 DEPRESSURIZATION STP RACTION/EXPECTED

RESPONSE

NOT OBTAINED 13 Verify Feed Pump Operation:

a. Both feedwater pump breakers
a. Stop feed pumps.

OPEN.

14 Depressurize RCS:

a. Throttle FC 1115 A, B
a. IF unable to AND C OR normal pressurizer oepressurize, THEN use spay T depressurize RCS one PORV.

to 400 psig.

b. Attempt to maintain pressurizer level at approximately 501.

15 Evaluate Plant Status:

a. Determine if RHR
a. IF NOT, THEN return can be placed in So 01-1.2-1.0 service for cooldown LOSS OF REACTOR per 501-4-9, RESIDUAL COOLANT.

HEAT REMOVAL SYSTEM OPERATION.

-END H. E. MORGAN

MANAGER, STATION OPERATIONS 9 of 10

S01-1.2-1.12 Rev 0 MDTQOFI DRIEN AFc' P'UM~PRE.ART C TER:.

a.

IF a motor driver AFW pump trips on low discharoe pressure, THEN:

1)

Lower AFW'flow controllers.

2)

Reset AND restart pump.

SI TERMINATION CRITERIA FOLLOWING LOSS OF REACTOR COOLANT

a.

Terminate SI when ALL parameters listed below are met:

1)

RCS Pressure

- GREATER THAN 1400 PSIG.

2)

RCS Subcooling

- 40 oF.

3) Pressurizer Level

- GREATER THAN 501.

4) Heat Sink:

(a) SG Level

- 10% N. R.

OR (b) AFW Flow

- 250 GPM.

SI REINITIATION CRITERIA FOLLOWING LOSS OF REACTOR COOLANT

a.

Reinitiate SI if ANY ONE of the parameters listed below occurs:

1)

RCS Pressure LESS THAN 1400 PSIG.

2) RCS Subcooling LESS THAN 40 CF
3) Pressurizer Level LESS THAN 201.

COLD LEG RECIRCULATION SWITCHOVER CRITERIA

a. IF RWST level less than 211, THEN align SI systemr for cold leg injection and recirculation per O-1.2-T.T3, TRANSFER TO COLD LEG IWJECTION AND RECIRCULATION.

SYMPTOMS FOR RESPONSE TO IADEQUATE CORE COOLING

a.

Go to 501-1.2-14, RESPONSE TO INADEQUATE CORE COOLING, When ANY ONE of the following symptoms occur:

1)

Five or more core exit TCs -

GREATER THAN 1200 OF.

OR

2)

RCS hot leg temperatures -

GREATER THAN 700 oF.

SYMPTOMS FOR RESPONSE TO LOSS OF SECONDARY HEAT SINK

a.

Go to S01-1.2-15, RESPONSE TO LOSS OF SECONDARY HEAT SINK, IF AFW Flow is NOT AVAILABLE.

IF EVENTS REQUIRE IMPLEMENTATION OF THIS PROCEDURE

a. Notify Watch Engineer.
b. Notify Shift Technical Advisor.
c. Notify Shift Communicator.
d. Deterwine if event is classified as an energency and requires notification of offsite agencies and implementation of the Emergency Plan per 50123-VIII-11, RECOGNITION AND CLASSIFICATION OF EMERGENCIES.
e.

IF event is NOT classified as an emergency in d above THEN determine if fZtification of the NRC is required within one hour per S01-14-13, NOTIFICATION TO NRC OF SIGNIFICANT EVENTS.

10 of 10