MONTHYEARML15043A3952015-02-0606 February 2015 Shine Medical Technologies, Inc. - Application for Construction Permit - Response to Request for Additional Information ML13309B6342013-10-0404 October 2013 Shine Medical Technologies, Inc. Application for Construction Permit Response to Environmental Requests for Additional Information, Enclosure 2, Attachment 37, PSAR Figure 19.2.2-1 Rev 1 ML13309B0052013-10-0404 October 2013 Shine Medical Technologies, Inc. Application for Construction Permit Response to Environmental Requests for Additional Information, Enclosure 2 Attachment 16 - Drawing 1-HM-SK-001, Rev a Shine Simplified Site ML13221A3652013-08-0808 August 2013 Attachment 18 - Figure 19.2.2-1, Revision 1, Isotope Production System High-Level Flow Diagram ML13309B0412013-02-10010 February 2013 Shine Medical Technologies, Inc. Application for Construction Permit Response to Environmental Requests for Additional Information, Enclosure 2 Attachment 19 - Draft Phase I Environmental Site Assessment (Stevens Point, Wi), Part 7 of 9 ML13309B6262012-08-0303 August 2012 Shine Medical Technologies, Inc., Application for Construction Permit Response to Environmental Requests for Additional Information, Enclosure 2 Attachment 24 - Seismic Hazard Assesment Report (Janesville) Rev 4, Part 2 of 2 ML13309B0402012-02-10010 February 2012 Shine Medical Technologies, Inc., Application for Construction Permit Response to Environmental Requests for Additional Information, Enclosure 2 Attachment 19 - Draft Phase I Environmental Site Assessment (Stevens Point, Wi), Part 6 of 9 ML13309B0392012-02-10010 February 2012 Shine Medical Technologies, Inc., Application for Construction Permit Response to Environmental Requests for Additional Information, Enclosure 2 Attachment 19 - Draft Phase I Environmental Site Assessment (Stevens Point, Wi), Part 5 of 9 ML13309B0382012-02-10010 February 2012 Shine Medical Technologies, Inc., Application for Construction Permit Response to Environmental Requests for Additional Information, Enclosure 2 Attachment 19 - Draft Phase I Environmental Site Assessment (Stevens Point, Wi), Part 4 of 9 ML13309B0372012-02-10010 February 2012 Shine Medical Technologies, Inc., Application for Construction Permit Response to Environmental Requests for Additional Information, Enclosure 2 Attachment 19 - Draft Phase I Environmental Site Assessment (Stevens Point, Wi) (Part 3 of 9) ML13309B0332012-02-10010 February 2012 Shine Medical Technologies, Inc., Application for Construction Permit Response to Environmental Requests for Additional Information, Enclosure 2 Attachment 19 - Draft Phase I Environmental Site Assessment (Stevens Point, Wi), Part 9 of 9 ML13309B0322012-02-10010 February 2012 Shine Medical Technologies, Inc., Application for Construction Permit Response to Environmental Requests for Additional Information, Enclosure 2 Attachment 19 - Draft Phase I Environmental Site Assessment (Stevens Point, Wi), Part 8 of 9 ML13309B6332004-08-31031 August 2004 Shine Medical Technologies, Inc. Application for Construction Permit Response to Environmental Requests for Additional Information, Enclosure 2, Attachment 36 - Southern Wisconsin Regional Land Use Drawing Rev 1 2015-02-06
[Table view] |
Text
ENCLOSURE 2 ATTACHMENT 37 SHINE MEDICAL TECHNOLOGIES, INC.
SHINE MEDICAL TECHNOLOGIES, INC. APPLICATION FOR CONSTRUCTION PERMIT RESPONSE TO ENVIRONMENTAL REQUESTS FOR ADDITIONAL INFORMATION PSAR FIGURE 19.2.2 ISOTOPE PRODUCTION SYSTEM HIGH-LEVEL FLOW DIAGRAM REVISION 1 1 page follows
Chapter 19 - Environmental Review Radioisotope Facility Description Figure 19.2.2-1 -Isotope Production System High-Level Flow Diagram Tritium Purification Abbreviations Tritium System 99 Mo- Molybdenum-99 D- Deuterium 1-'-
!;;o ~
FPs - Fission Products GJ"'C ::> LEU- Low enriched uranium
.~ c 0.
E '" Sol'n- Solution T - Tritium TSV- Target solution vessel UREX- Uranium extraction Neutron Driver Deuterium c:
E! .----------radiolytic gases, FPs- - - - - -- -- --..
'5QJ c:
1 recirculating gas, 1'4-- - - -- - -- recombined HzO, FPs- - - - - - - - 1 TSV Off-gas System Subcritical Assembly target Uranium sol'n Target Sol'n Preparation/
Adjustment
.--- - -FP no 99 Mo Extraction
[ Solid Waste J L----------------- FP ~--------------~ Radwaste Systems 1.-.-- - - -spent columns,._ _ _ _ _ _ _ _ _ _ __ _'l"---~
effluent 99 Mo Purification (LEU-modified 1 - - - - - -- - - - - -glassware, effluent, columns------'
Cintichem)
Product Packaging Punf1Pd Mo Prodta t SHINE Medical Technologies Rev. 1