6 pages follow ENCLOSURE 2 ATTACHMENT 11 SHINE MEDICAL TECHNOLOGIES, INC.
SHINE MEDICAL TECHNOLOGIES, INC. APPLICATION FOR CONSTRUCTION PERMIT RESPONSE TO ENVIRONMENTAL REQUESTS FOR ADDITIONAL INFORMATION AERMOD TERRAIN DATA OUTPUT FILE
aermap
- AERMAP - VERSION 11103 08/09/13
- 13:36:13 CO STARTING TITLEONE Elevation data for SHINE DATATYPE DEM DATAFILE C:\\AERMOD\\AERMAP_EXE\\BELOIT_DEM.DEM DATAFILE C:\\AERMOD\\AERMAP_EXE\\JAIN_DEM.DEM DOMAINXY 333000 4720000 16 335000 4730000 16 ANCHORXY 0.0 0.0 333947 4720850 16 0 RUNORNOT RUN CO FINISHED SO STARTING LOCATION MAINPROC POINT -23 -34 843 LOCATION MAINHEAT POINT -15 -45 843 LOCATION ADMINHTR POINT -153 42 831 LOCATION SUPPHTR POINT 10 -115 833 LOCATION WASTEHTR POINT 41 -34 832 LOCATION DIESLHTR POINT 47 69 831 SO FINISHED RE STARTING
- Define site boundary DISCCART 302 294 DISCCART -147 308 DISCCART -373 94 DISCCART -422 -43 DISCCART -469 -207 DISCCART -241 -211 DISCCART -165 -267 DISCCART 309 DISCCART 68 -311 DISCCART 244 -218 DISCCART 302 -218 DISCCART 107 303 DISCCART -54 306 DISCCART -188 268 DISCCART -279 180 DISCCART -396 27 DISCCART -441 -128 DISCCART -435 -208 DISCCART -206 237 DISCCART -131 -285 DISCCART 0 -309 DISCCART 167 -258 DISCCART 300 -142 DISCCART 298 0
- Define site boundary grids out 100m; WEST BOUNDARY DISCCART -468.6376105 -205.5470893 DISCCART -493.6376105 -205.5470893 DISCCART -518.6376105 -205.5470893 DISCCART -543.6376105 -205.5470893 DISCCART -568.6376105 -205.5470893 DISCCART -463.2733923 -180.5470893 DISCCART -488.2733923 -180.5470893 DISCCART -513.2733923 -180.5470893 DISCCART -538.2733923 -180.5470893 DISCCART -563.2733923 -180.5470893 DISCCART -454.0079244 -155.5470893 DISCCART -479.0079244 -155.5470893 DISCCART -504.0079244 -155.5470893 DISCCART -529.0079244 -155.5470893 Page 1
aermap DISCCART -554.0079244 -155.5470893 DISCCART -448.15605 -130.5470893 DISCCART -498.15605 -130.5470893 DISCCART -523.15605 -130.5470893 DISCCART -548.15605 -130.5470893 DISCCART -440.1097226 -105.5470893 DISCCART -465.1097226 -105.5470893 DISCCART -490.1097226 -105.5470893 DISCCART -515.1097226 -105.5470893 DISCCART -540.1097226 -105.5470893 DISCCART -433.5263639 -80.5470893 DISCCART -458.5263639 -80.5470893 DISCCART -483.5263639 -80.5470893 DISCCART -508.5263639 -80.5470893 DISCCART -533.5263639 -80.5470893 DISCCART -426.2115209 -55.5470893 DISCCART -451.2115209 -55.5470893 DISCCART -476.2115209 -55.5470893 DISCCART -501.2115209 -55.5470893 DISCCART -526.2115209 -55.5470893 DISCCART -414.507772 -30.5470893 DISCCART -439.507772 -30.5470893 DISCCART -464.507772 -30.5470893 DISCCART -489.507772 -30.5470893 DISCCART -514.507772 -30.5470893 DISCCART -403.0478513 -5.547089302 DISCCART -428.0478513 -5.547089302 DISCCART -453.0478513 -5.547089302 DISCCART -478.0478513 -5.547089302 DISCCART -503.0478513 -5.547089302 DISCCART -399.3904297 19.4529107 DISCCART -424.3904297 19.4529107 DISCCART -449.3904297 19.4529107 DISCCART -474.3904297 19.4529107 DISCCART -499.3904297 19.4529107 DISCCART -388.1743371 44.4529107 DISCCART -413.1743371 44.4529107 DISCCART -438.1743371 44.4529107 DISCCART -463.1743371 44.4529107 DISCCART -488.1743371 44.4529107 DISCCART -382.3224627 69.4529107 DISCCART -407.3224627 69.4529107 DISCCART -432.3224627 69.4529107 DISCCART -457.3224627 69.4529107 DISCCART -482.3224627 69.4529107 DISCCART -374.2761353 94.4529107 DISCCART -399.2761353 94.4529107 DISCCART -424.2761353 94.4529107 DISCCART -449.2761353 94.4529107 DISCCART -474.2761353 94.4529107 DISCCART -345.9920756 119.4529107 DISCCART -370.9920756 119.4529107 DISCCART -395.9920756 119.4529107 DISCCART -420.9920756 119.4529107 DISCCART -445.9920756 119.4529107 DISCCART -316.4888753 144.4529107 DISCCART -341.4888753 144.4529107 DISCCART -366.4888753 144.4529107 DISCCART -391.4888753 144.4529107 DISCCART -416.4888753 144.4529107 DISCCART -294.5443462 169.4529107 DISCCART -319.5443462 169.4529107 DISCCART -344.5443462 169.4529107 Page 2
aermap DISCCART -369.5443462 169.4529107 DISCCART -394.5443462 169.4529107 DISCCART -263.8220055 194.4529107 DISCCART -288.8220055 194.4529107 DISCCART -313.8220055 194.4529107 DISCCART -338.8220055 194.4529107 DISCCART -363.8220055 194.4529107 DISCCART -237.4885706 219.4529107 DISCCART -262.4885706 219.4529107 DISCCART -287.4885706 219.4529107 DISCCART -312.4885706 219.4529107 DISCCART -337.4885706 219.4529107 DISCCART -208.2291984 244.4529107 DISCCART -233.2291984 244.4529107 DISCCART -258.2291984 244.4529107 DISCCART -283.2291984 244.4529107 DISCCART -308.2291984 244.4529107 DISCCART -190.1859189 269.4529107 DISCCART -215.1859189 269.4529107 DISCCART -240.1859189 269.4529107 DISCCART -265.1859189 269.4529107 DISCCART -290.1859189 269.4529107 DISCCART -164.3401402 294.4529107 DISCCART -189.3401402 294.4529107 DISCCART -214.3401402 294.4529107 DISCCART -239.3401402 294.4529107 DISCCART -264.3401402 294.4529107 DISCCART -146.7845169 319.4529107 DISCCART -171.7845169 319.4529107 DISCCART -196.7845169 319.4529107 DISCCART -221.7845169 319.4529107 DISCCART -246.7845169 319.4529107
- END WEST WALL GRID
- SOUTH WALL GRID ON DIAGONAL SECTIONS DISCCART -240.6583359 -209.692167 DISCCART -240.6583359 -234.692167 DISCCART -240.6583359 -259.692167 DISCCART -240.6583359 -284.692167 DISCCART -240.6583359 -309.692167 DISCCART -205.5470893 -234.692167 DISCCART -205.5470893 -259.692167 DISCCART -205.5470893 -284.692167 DISCCART -205.5470893 -309.692167 DISCCART -205.5470893 -334.692167 DISCCART -171.4111551 -259.692167 DISCCART -171.4111551 -284.692167 DISCCART -171.4111551 -309.692167 DISCCART -171.4111551 -334.692167 DISCCART -171.4111551 -359.692167 DISCCART -128.4974093 -284.692167 DISCCART -128.4974093 -309.692167 DISCCART -128.4974093 -334.692167 DISCCART -128.4974093 -359.692167 DISCCART -128.4974093 -384.692167 DISCCART -83.63303871 -309.692167 DISCCART -83.63303871 -334.692167 DISCCART -83.63303871 -359.692167 DISCCART -83.63303871 -384.692167 DISCCART -83.63303871 -409.692167 DISCCART 67.54038403 -334.692167 DISCCART 67.54038403 -359.692167 DISCCART 67.54038403 -384.692167 DISCCART 67.54038403 -409.692167 Page 3
aermap DISCCART 67.54038403 -434.692167 DISCCART 67.54038403 -309.692167 DISCCART 67.54038403 -334.692167 DISCCART 67.54038403 -359.692167 DISCCART 67.54038403 -384.692167 DISCCART 67.54038403 -409.692167 DISCCART 112.4047546 -284.692167 DISCCART 112.4047546 -309.692167 DISCCART 112.4047546 -334.692167 DISCCART 112.4047546 -359.692167 DISCCART 112.4047546 -384.692167 DISCCART 165.0716245 -259.692167 DISCCART 165.0716245 -284.692167 DISCCART 165.0716245 -309.692167 DISCCART 165.0716245 -334.692167 DISCCART 165.0716245 -359.692167 DISCCART 210.9113075 -234.692167 DISCCART 210.9113075 -259.692167 DISCCART 210.9113075 -284.692167 DISCCART 210.9113075 -309.692167 DISCCART 210.9113075 -334.692167 DISCCART 246.0225541 -209.692167 DISCCART 246.0225541 -234.692167 DISCCART 246.0225541 -259.692167 DISCCART 246.0225541 -284.692167 DISCCART 246.0225541 -309.692167
- END SOUTH WALL DIAGONAL GRIDS
- REMAINING GRIDS AROUND SITE BOUNDARY GRIDCART GRID1 STA XYINC -521 30 40 291 10 40 END GRIDCART GRID2 STA XYINC -630 8 40 -219 13 40 END GRIDCART GRID3 STA XYINC -475 20 40 -470 6 40 END GRIDCART GRID4 STA XYINC 300 5 40 -400 20 40 END GRIDCART FINE5 STA XYINC -146 18 25 300 4 25 END GRIDCART FINE6 STA XYINC 300 4 25 -400 28 25 END GRIDCART FINE7 STA XYINC -467 9 25 -307 4 25 END GRIDCART FINE8 STA XYINC -82 6 25 -410 4 25 END GRIDCART FINE9 STA XYINC 250 2 25 -315 4 25 END RE FINISHED OU STARTING RECEPTOR RECFIL.OUT SOURCLOC SRCFIL.OUT OU FINISHED Exiting DEMCHK Page 4
aermap Finished Reading Input DEM Data Exiting CHKADJ Exiting DOMCNV Exiting RECCNV Exiting SRCCNV Exiting CHKEXT Exiting DEMREC Exiting DEMSRC
- SETUP Finishes Successfully ***
- AERMAP - VERSION 11103 *** *** Elevation data for SHINE
- 08/09/13
- 13:36:13
- AERMAP SETUP OPTIONS
SUMMARY
- This Run Includes: 2 DEM File(s)
- This Run Includes: 1064 Receptor(s); and 6 Source(s)
- The Input Receptors and Sources Were Assigned a NADA Value of 0: No NAD Shifts Included in Calculations
- The Input Receptors and Sources Are Offset: 333947.00 meters East; 4720850.00 meters North from the User-specified Anchor Point at: 333947.00 meters East; 4720850.00 meters North; Zone 16
- Terrain heights were EXTRACTed from DEM data
- The Following Debug Output Files Have Been Automatically Generated:
DOMDETAIL.OUT - Details of User-specified Domain and Relation to DEM Files MAPDETAIL.OUT - Details Regarding Input DEM Files MAPPARAMS.OUT - Summary of DEM File Parameters and DEM File Adjacency
- AERMAP - VERSION 11103 *** *** Elevation data for SHINE
- 08/09/13
- 13:36:13
- Message Summary For AERMAP Execution ***
Summary of Total Messages --------
A Total of 0 Fatal Error Message(s)
A Total of 0 Warning Message(s)
A Total of 0 Informational Message(s)
- FATAL ERROR MESSAGES ********
- NONE ***
Page 5
aermap
- WARNING MESSAGES ********
- NONE ***
- AERMAP Finishes Successfully ***
Page 6