4 pages follow ENCLOSURE 2 ATTACHMENT 10 SHINE MEDICAL TECHNOLOGIES, INC.

SHINE MEDICAL TECHNOLOGIES, INC. APPLICATION FOR CONSTRUCTION PERMIT RESPONSE TO ENVIRONMENTAL REQUESTS FOR ADDITIONAL INFORMATION AERMOD TERRAIN DATA INPUT FILE

aermap CO STARTING TITLEONE Elevation data for SHINE DATATYPE DEM DATAFILE C:\\AERMOD\\AERMAP_EXE\\BELOIT_DEM.DEM DATAFILE C:\\AERMOD\\AERMAP_EXE\\JAIN_DEM.DEM DOMAINXY 333000 4720000 16 335000 4730000 16 ANCHORXY 0.0 0.0 333947 4720850 16 0 RUNORNOT RUN CO FINISHED SO STARTING LOCATION MAINPROC POINT -23 -34 LOCATION MAINHEAT POINT -15 -45 LOCATION ADMINHTR POINT -153 42 LOCATION SUPPHTR POINT 10 -115 LOCATION WASTEHTR POINT 41 -34 LOCATION DIESLHTR POINT 47 69 SO FINISHED RE STARTING

    • Define site boundary DISCCART 302 294 DISCCART -147 308 DISCCART -373 94 DISCCART -422 -43 DISCCART -469 -207 DISCCART -241 -211 DISCCART -165 -267 DISCCART 309 DISCCART 68 -311 DISCCART 244 -218 DISCCART 302 -218 DISCCART 107 303 DISCCART -54 306 DISCCART -188 268 DISCCART -279 180 DISCCART -396 27 DISCCART -441 -128 DISCCART -435 -208 DISCCART -206 237 DISCCART -131 -285 DISCCART 0 -309 DISCCART 167 -258 DISCCART 300 -142 DISCCART 298 0
    • Define site boundary grids out 100m; WEST BOUNDARY DISCCART -468.6376105 -205.5470893 DISCCART -493.6376105 -205.5470893 DISCCART -518.6376105 -205.5470893 DISCCART -543.6376105 -205.5470893 DISCCART -568.6376105 -205.5470893 DISCCART -463.2733923 -180.5470893 DISCCART -488.2733923 -180.5470893 DISCCART -513.2733923 -180.5470893 DISCCART -538.2733923 -180.5470893 DISCCART -563.2733923 -180.5470893 DISCCART -454.0079244 -155.5470893 DISCCART -479.0079244 -155.5470893 DISCCART -504.0079244 -155.5470893 DISCCART -529.0079244 -155.5470893 DISCCART -554.0079244 -155.5470893 DISCCART -448.15605 -130.5470893 DISCCART -498.15605 -130.5470893 Page 1

aermap DISCCART -523.15605 -130.5470893 DISCCART -548.15605 -130.5470893 DISCCART -440.1097226 -105.5470893 DISCCART -465.1097226 -105.5470893 DISCCART -490.1097226 -105.5470893 DISCCART -515.1097226 -105.5470893 DISCCART -540.1097226 -105.5470893 DISCCART -433.5263639 -80.5470893 DISCCART -458.5263639 -80.5470893 DISCCART -483.5263639 -80.5470893 DISCCART -508.5263639 -80.5470893 DISCCART -533.5263639 -80.5470893 DISCCART -426.2115209 -55.5470893 DISCCART -451.2115209 -55.5470893 DISCCART -476.2115209 -55.5470893 DISCCART -501.2115209 -55.5470893 DISCCART -526.2115209 -55.5470893 DISCCART -414.507772 -30.5470893 DISCCART -439.507772 -30.5470893 DISCCART -464.507772 -30.5470893 DISCCART -489.507772 -30.5470893 DISCCART -514.507772 -30.5470893 DISCCART -403.0478513 -5.547089302 DISCCART -428.0478513 -5.547089302 DISCCART -453.0478513 -5.547089302 DISCCART -478.0478513 -5.547089302 DISCCART -503.0478513 -5.547089302 DISCCART -399.3904297 19.4529107 DISCCART -424.3904297 19.4529107 DISCCART -449.3904297 19.4529107 DISCCART -474.3904297 19.4529107 DISCCART -499.3904297 19.4529107 DISCCART -388.1743371 44.4529107 DISCCART -413.1743371 44.4529107 DISCCART -438.1743371 44.4529107 DISCCART -463.1743371 44.4529107 DISCCART -488.1743371 44.4529107 DISCCART -382.3224627 69.4529107 DISCCART -407.3224627 69.4529107 DISCCART -432.3224627 69.4529107 DISCCART -457.3224627 69.4529107 DISCCART -482.3224627 69.4529107 DISCCART -374.2761353 94.4529107 DISCCART -399.2761353 94.4529107 DISCCART -424.2761353 94.4529107 DISCCART -449.2761353 94.4529107 DISCCART -474.2761353 94.4529107 DISCCART -345.9920756 119.4529107 DISCCART -370.9920756 119.4529107 DISCCART -395.9920756 119.4529107 DISCCART -420.9920756 119.4529107 DISCCART -445.9920756 119.4529107 DISCCART -316.4888753 144.4529107 DISCCART -341.4888753 144.4529107 DISCCART -366.4888753 144.4529107 DISCCART -391.4888753 144.4529107 DISCCART -416.4888753 144.4529107 DISCCART -294.5443462 169.4529107 DISCCART -319.5443462 169.4529107 DISCCART -344.5443462 169.4529107 DISCCART -369.5443462 169.4529107 DISCCART -394.5443462 169.4529107 DISCCART -263.8220055 194.4529107 Page 2

aermap DISCCART -288.8220055 194.4529107 DISCCART -313.8220055 194.4529107 DISCCART -338.8220055 194.4529107 DISCCART -363.8220055 194.4529107 DISCCART -237.4885706 219.4529107 DISCCART -262.4885706 219.4529107 DISCCART -287.4885706 219.4529107 DISCCART -312.4885706 219.4529107 DISCCART -337.4885706 219.4529107 DISCCART -208.2291984 244.4529107 DISCCART -233.2291984 244.4529107 DISCCART -258.2291984 244.4529107 DISCCART -283.2291984 244.4529107 DISCCART -308.2291984 244.4529107 DISCCART -190.1859189 269.4529107 DISCCART -215.1859189 269.4529107 DISCCART -240.1859189 269.4529107 DISCCART -265.1859189 269.4529107 DISCCART -290.1859189 269.4529107 DISCCART -164.3401402 294.4529107 DISCCART -189.3401402 294.4529107 DISCCART -214.3401402 294.4529107 DISCCART -239.3401402 294.4529107 DISCCART -264.3401402 294.4529107 DISCCART -146.7845169 319.4529107 DISCCART -171.7845169 319.4529107 DISCCART -196.7845169 319.4529107 DISCCART -221.7845169 319.4529107 DISCCART -246.7845169 319.4529107

    • END WEST WALL GRID
    • SOUTH WALL GRID ON DIAGONAL SECTIONS DISCCART -240.6583359 -209.692167 DISCCART -240.6583359 -234.692167 DISCCART -240.6583359 -259.692167 DISCCART -240.6583359 -284.692167 DISCCART -240.6583359 -309.692167 DISCCART -205.5470893 -234.692167 DISCCART -205.5470893 -259.692167 DISCCART -205.5470893 -284.692167 DISCCART -205.5470893 -309.692167 DISCCART -205.5470893 -334.692167 DISCCART -171.4111551 -259.692167 DISCCART -171.4111551 -284.692167 DISCCART -171.4111551 -309.692167 DISCCART -171.4111551 -334.692167 DISCCART -171.4111551 -359.692167 DISCCART -128.4974093 -284.692167 DISCCART -128.4974093 -309.692167 DISCCART -128.4974093 -334.692167 DISCCART -128.4974093 -359.692167 DISCCART -128.4974093 -384.692167 DISCCART -83.63303871 -309.692167 DISCCART -83.63303871 -334.692167 DISCCART -83.63303871 -359.692167 DISCCART -83.63303871 -384.692167 DISCCART -83.63303871 -409.692167 DISCCART 67.54038403 -334.692167 DISCCART 67.54038403 -359.692167 DISCCART 67.54038403 -384.692167 DISCCART 67.54038403 -409.692167 DISCCART 67.54038403 -434.692167 DISCCART 67.54038403 -309.692167 DISCCART 67.54038403 -334.692167 Page 3

aermap DISCCART 67.54038403 -359.692167 DISCCART 67.54038403 -384.692167 DISCCART 67.54038403 -409.692167 DISCCART 112.4047546 -284.692167 DISCCART 112.4047546 -309.692167 DISCCART 112.4047546 -334.692167 DISCCART 112.4047546 -359.692167 DISCCART 112.4047546 -384.692167 DISCCART 165.0716245 -259.692167 DISCCART 165.0716245 -284.692167 DISCCART 165.0716245 -309.692167 DISCCART 165.0716245 -334.692167 DISCCART 165.0716245 -359.692167 DISCCART 210.9113075 -234.692167 DISCCART 210.9113075 -259.692167 DISCCART 210.9113075 -284.692167 DISCCART 210.9113075 -309.692167 DISCCART 210.9113075 -334.692167 DISCCART 246.0225541 -209.692167 DISCCART 246.0225541 -234.692167 DISCCART 246.0225541 -259.692167 DISCCART 246.0225541 -284.692167 DISCCART 246.0225541 -309.692167

    • END SOUTH WALL DIAGONAL GRIDS
    • REMAINING GRIDS AROUND SITE BOUNDARY GRIDCART GRID1 STA XYINC -521 30 40 291 10 40 END GRIDCART GRID2 STA XYINC -630 8 40 -219 13 40 END GRIDCART GRID3 STA XYINC -475 20 40 -470 6 40 END GRIDCART GRID4 STA XYINC 300 5 40 -400 20 40 END GRIDCART FINE5 STA XYINC -146 18 25 300 4 25 END GRIDCART FINE6 STA XYINC 300 4 25 -400 28 25 END GRIDCART FINE7 STA XYINC -467 9 25 -307 4 25 END GRIDCART FINE8 STA XYINC -82 6 25 -410 4 25 END GRIDCART FINE9 STA XYINC 250 2 25 -315 4 25 END RE FINISHED OU STARTING RECEPTOR RECFIL.OUT SOURCLOC SRCFIL.OUT OU FINISHED Page 4