5 pages follow ENCLOSURE 2 ATTACHMENT 9 SHINE MEDICAL TECHNOLOGIES, INC.
SHINE MEDICAL TECHNOLOGIES, INC. APPLICATION FOR CONSTRUCTION PERMIT RESPONSE TO ENVIRONMENTAL REQUESTS FOR ADDITIONAL INFORMATION AERMOD BUILDING DATA OUTPUT FILE
building_data BPIP model of SHINE production facility and surrounding buildings BPIP (Dated: 04274)
DATE : 8/ 6/2013 TIME : 16:10:30 BPIP model of SHINE production facility and surrounding buildings
================
BPIP PROCESSING INFORMATION:
================
The P flag has been set for preparing downwash related data for a model run utilizing the PRIME algorithm.
Inputs entered in METERS will be converted to meters using a conversion factor of 1.0000. Output will be in meters.
UTMP is set to UTMN. The input is assumed to be in a local X-Y coordinate system as opposed to a UTM coordinate system.
True North is in the positive Y direction.
Plant north is set to 0.00 degrees with respect to True North.
BPIP model of SHINE production facility and surrounding buildings PRELIMINARY* GEP STACK HEIGHT RESULTS TABLE (Output Units: meters)
Stack-Building Preliminary*
Stack Stack Base Elevation GEP** GEP Stack Name Height Differences EQN1 Height Value MAINPROC 20.12 17.00 25.50 65.00 MAINHEAT 20.12 17.00 25.50 65.00 ADMINHTR 6.40 5.00 7.25 65.00 SUPPHTR 7.90 7.00 35.50 65.00 WASTEHTR 7.00 6.00 36.50 65.00 DIESLHTR 6.70 5.00 37.50 65.00
- Results are based on Determinants 1 & 2 on pages 1 & 2 of the GEP Technical Support Document. Determinant 3 may be investigated for additional stack height credit. Final values result after Determinant 3 has been taken into consideration.
- Results were derived from Equation 1 on page 6 of GEP Technical Support Document. Values have been adjusted for any stack-building base elevation differences.
Note: Criteria for determining stack heights for modeling emission limitations for a source can be found in Table 3.1 of the GEP Technical Support Document.
BPIP (Dated: 04274)
DATE : 8/ 6/2013 TIME : 16:10:30 Page 1
building_data BPIP model of SHINE production facility and surrounding buildings BPIP output is in meters SO BUILDHGT MAINPROC 17.00 17.00 17.00 17.00 17.00 17.00 SO BUILDHGT MAINPROC 17.00 17.00 17.00 17.00 17.00 17.00 SO BUILDHGT MAINPROC 17.00 17.00 17.00 17.00 17.00 17.00 SO BUILDHGT MAINPROC 17.00 17.00 17.00 17.00 17.00 17.00 SO BUILDHGT MAINPROC 17.00 17.00 17.00 17.00 17.00 17.00 SO BUILDHGT MAINPROC 17.00 17.00 17.00 17.00 17.00 17.00 SO BUILDWID MAINPROC 71.86 83.01 91.64 97.49 100.38 100.21 SO BUILDWID MAINPROC 97.00 90.85 85.58 94.40 100.35 103.25 SO BUILDWID MAINPROC 103.01 99.65 93.25 84.03 72.25 58.76 SO BUILDWID MAINPROC 71.86 83.01 91.64 97.49 100.38 100.21 SO BUILDWID MAINPROC 97.00 90.85 85.58 94.40 100.35 103.25 SO BUILDWID MAINPROC 103.01 99.65 93.25 84.03 72.25 58.76 SO BUILDLEN MAINPROC 94.40 100.35 103.25 103.01 99.65 93.25 SO BUILDLEN MAINPROC 84.03 72.25 58.76 71.86 83.01 91.64 SO BUILDLEN MAINPROC 97.49 100.38 100.21 97.00 90.85 85.58 SO BUILDLEN MAINPROC 94.40 100.35 103.25 103.01 99.65 93.25 SO BUILDLEN MAINPROC 84.03 72.25 58.76 71.86 83.01 91.64 SO BUILDLEN MAINPROC 97.49 100.38 100.21 97.00 90.85 85.58 SO XBADJ MAINPROC -11.23 -13.46 -15.27 -16.62 -17.46 -17.78 SO XBADJ MAINPROC -17.55 -16.79 -16.01 -28.62 -40.35 -50.86 SO XBADJ MAINPROC -59.82 -66.97 -72.08 -75.00 -75.65 -76.91 SO XBADJ MAINPROC -83.17 -86.89 -87.98 -86.40 -82.19 -75.48 SO XBADJ MAINPROC -66.48 -55.46 -42.75 -43.24 -42.66 -40.78 SO XBADJ MAINPROC -37.67 -33.41 -28.13 -22.00 -15.20 -8.67 SO YBADJ MAINPROC -7.31 -1.16 5.04 11.08 16.78 21.98 SO YBADJ MAINPROC 26.50 30.22 34.12 35.97 36.72 36.36 SO YBADJ MAINPROC 34.89 32.36 28.85 24.46 19.33 13.37 SO YBADJ MAINPROC 7.31 1.16 -5.04 -11.08 -16.78 -21.98 SO YBADJ MAINPROC -26.50 -30.22 -34.12 -35.97 -36.72 -36.36 SO YBADJ MAINPROC -34.89 -32.36 -28.85 -24.46 -19.33 -13.37 SO BUILDHGT MAINHEAT 17.00 17.00 17.00 17.00 17.00 17.00 SO BUILDHGT MAINHEAT 17.00 17.00 17.00 17.00 17.00 17.00 SO BUILDHGT MAINHEAT 17.00 17.00 17.00 17.00 17.00 17.00 SO BUILDHGT MAINHEAT 17.00 17.00 17.00 17.00 17.00 17.00 SO BUILDHGT MAINHEAT 17.00 17.00 17.00 17.00 17.00 17.00 SO BUILDHGT MAINHEAT 17.00 17.00 17.00 17.00 17.00 17.00 SO BUILDWID MAINHEAT 71.86 83.01 91.64 97.49 100.38 100.21 SO BUILDWID MAINHEAT 97.00 90.85 85.58 94.40 100.35 103.25 SO BUILDWID MAINHEAT 103.01 99.65 93.25 84.03 72.25 58.76 SO BUILDWID MAINHEAT 71.86 83.01 91.64 97.49 100.38 100.21 SO BUILDWID MAINHEAT 97.00 90.85 85.58 94.40 100.35 103.25 SO BUILDWID MAINHEAT 103.01 99.65 93.25 84.03 72.25 58.76 SO BUILDLEN MAINHEAT 94.40 100.35 103.25 103.01 99.65 93.25 SO BUILDLEN MAINHEAT 84.03 72.25 58.76 71.86 83.01 91.64 SO BUILDLEN MAINHEAT 97.49 100.38 100.21 97.00 90.85 85.58 SO BUILDLEN MAINHEAT 94.40 100.35 103.25 103.01 99.65 93.25 SO BUILDLEN MAINHEAT 84.03 72.25 58.76 71.86 83.01 91.64 SO BUILDLEN MAINHEAT 97.49 100.38 100.21 97.00 90.85 85.58 SO XBADJ MAINHEAT -1.79 -5.85 -9.74 -13.33 -16.52 -19.20 SO XBADJ MAINHEAT -21.30 -22.76 -24.01 -38.40 -51.63 -63.29 SO XBADJ MAINHEAT -73.02 -80.54 -85.61 -88.08 -87.87 -87.91 SO XBADJ MAINHEAT -92.61 -94.49 -93.51 -89.68 -83.13 -74.05 SO XBADJ MAINHEAT -62.72 -49.49 -34.75 -33.45 -31.38 -28.36 SO XBADJ MAINHEAT -24.47 -19.84 -14.60 -8.93 -2.98 2.33 SO YBADJ MAINHEAT 2.47 10.12 17.47 24.28 30.35 35.50 Page 2
building_data SO YBADJ MAINHEAT 39.57 42.44 45.12 45.41 44.32 41.88 SO YBADJ MAINHEAT 38.17 33.30 27.42 20.71 13.36 5.37 SO YBADJ MAINHEAT -2.47 -10.12 -17.47 -24.28 -30.35 -35.50 SO YBADJ MAINHEAT -39.57 -42.44 -45.12 -45.41 -44.32 -41.88 SO YBADJ MAINHEAT -38.17 -33.30 -27.42 -20.71 -13.36 -5.37 SO BUILDHGT ADMINHTR 4.90 4.90 4.90 4.90 4.90 4.90 SO BUILDHGT ADMINHTR 4.90 4.90 4.90 4.90 4.90 4.90 SO BUILDHGT ADMINHTR 4.90 4.90 4.90 4.90 4.90 4.90 SO BUILDHGT ADMINHTR 4.90 4.90 4.90 4.90 4.90 4.90 SO BUILDHGT ADMINHTR 4.90 4.90 4.90 4.90 4.90 4.90 SO BUILDHGT ADMINHTR 4.90 4.90 4.90 4.90 4.90 4.90 SO BUILDWID ADMINHTR 39.73 42.17 43.32 43.16 41.69 38.95 SO BUILDWID ADMINHTR 35.03 30.04 24.14 30.04 35.03 38.95 SO BUILDWID ADMINHTR 41.69 43.16 43.32 42.17 39.73 36.09 SO BUILDWID ADMINHTR 39.73 42.17 43.32 43.16 41.69 38.95 SO BUILDWID ADMINHTR 35.03 30.04 24.14 30.04 35.03 38.95 SO BUILDWID ADMINHTR 41.69 43.16 43.32 42.17 39.73 36.09 SO BUILDLEN ADMINHTR 30.04 35.03 38.95 41.69 43.16 43.32 SO BUILDLEN ADMINHTR 42.17 39.73 36.09 39.73 42.17 43.32 SO BUILDLEN ADMINHTR 43.16 41.69 38.95 35.03 30.04 24.14 SO BUILDLEN ADMINHTR 30.04 35.03 38.95 41.69 43.16 43.32 SO BUILDLEN ADMINHTR 42.17 39.73 36.09 39.73 42.17 43.32 SO BUILDLEN ADMINHTR 43.16 41.69 38.95 35.03 30.04 24.14 SO XBADJ ADMINHTR -21.09 -20.75 -19.77 -18.20 -16.08 -13.46 SO XBADJ ADMINHTR -10.44 -7.10 -3.54 -4.07 -4.47 -4.74 SO XBADJ ADMINHTR -4.87 -4.84 -4.67 -4.36 -3.91 -3.35 SO XBADJ ADMINHTR -8.95 -14.28 -19.18 -23.49 -27.09 -29.86 SO XBADJ ADMINHTR -31.73 -32.64 -32.55 -35.67 -37.70 -38.58 SO XBADJ ADMINHTR -38.30 -36.85 -34.28 -30.67 -26.13 -20.79 SO YBADJ ADMINHTR -15.80 -16.61 -16.92 -16.72 -16.00 -14.80 SO YBADJ ADMINHTR -13.16 -11.11 -8.72 -6.07 -3.23 -0.30 SO YBADJ ADMINHTR 2.64 5.51 8.20 10.65 12.77 14.51 SO YBADJ ADMINHTR 15.80 16.61 16.92 16.72 16.00 14.80 SO YBADJ ADMINHTR 13.16 11.11 8.72 6.07 3.23 0.30 SO YBADJ ADMINHTR -2.64 -5.51 -8.20 -10.65 -12.77 -14.51 SO BUILDHGT SUPPHTR 6.40 6.40 6.40 6.40 6.40 6.40 SO BUILDHGT SUPPHTR 6.40 6.40 6.40 6.40 6.40 6.40 SO BUILDHGT SUPPHTR 6.40 6.40 17.00 17.00 17.00 17.00 SO BUILDHGT SUPPHTR 17.00 6.40 6.40 6.40 6.40 6.40 SO BUILDHGT SUPPHTR 6.40 6.40 6.40 6.40 6.40 6.40 SO BUILDHGT SUPPHTR 6.40 6.40 6.40 6.40 6.40 6.40 SO BUILDWID SUPPHTR 50.01 53.13 54.64 54.49 52.69 49.28 SO BUILDWID SUPPHTR 44.38 38.13 30.72 37.65 43.92 48.85 SO BUILDWID SUPPHTR 52.31 54.17 93.25 84.03 72.25 58.76 SO BUILDWID SUPPHTR 71.86 53.13 54.64 54.49 52.69 49.28 SO BUILDWID SUPPHTR 44.38 38.13 30.72 37.65 43.92 48.85 SO BUILDWID SUPPHTR 52.31 54.17 54.39 52.95 49.91 45.60 SO BUILDLEN SUPPHTR 37.65 43.92 48.85 52.31 54.17 54.39 SO BUILDLEN SUPPHTR 52.95 49.91 45.60 50.01 53.13 54.64 SO BUILDLEN SUPPHTR 54.49 52.69 100.21 97.00 90.85 85.58 SO BUILDLEN SUPPHTR 94.40 43.92 48.85 52.31 54.17 54.39 SO BUILDLEN SUPPHTR 52.95 49.91 45.60 50.01 53.13 54.64 SO BUILDLEN SUPPHTR 54.49 52.69 49.28 44.38 38.13 30.72 SO XBADJ SUPPHTR -20.69 -27.01 -32.50 -37.01 -40.40 -42.56 SO XBADJ SUPPHTR -43.42 -42.97 -41.21 -43.21 -44.14 -43.73 SO XBADJ SUPPHTR -41.98 -38.97 -158.73 -162.41 -161.15 -157.91 SO XBADJ SUPPHTR -157.20 -16.91 -16.35 -15.29 -13.77 -11.83 SO XBADJ SUPPHTR -9.53 -6.94 -4.39 -6.79 -8.99 -10.92 SO XBADJ SUPPHTR -12.51 -13.72 -14.52 -14.87 -14.78 -14.23 Page 3
building_data SO YBADJ SUPPHTR 18.21 17.57 16.40 14.74 12.62 10.12 SO YBADJ SUPPHTR 7.32 4.29 1.13 -1.86 -5.05 -8.08 SO YBADJ SUPPHTR -10.86 -13.31 40.77 21.16 0.90 -19.63 SO YBADJ SUPPHTR -39.25 -17.57 -16.40 -14.74 -12.62 -10.12 SO YBADJ SUPPHTR -7.32 -4.29 -1.13 1.86 5.05 8.08 SO YBADJ SUPPHTR 10.86 13.31 15.36 16.95 18.01 18.41 SO BUILDHGT WASTEHTR 5.50 5.50 5.50 5.50 17.00 17.00 SO BUILDHGT WASTEHTR 17.00 17.00 17.00 17.00 17.00 17.00 SO BUILDHGT WASTEHTR 17.00 17.00 17.00 17.00 17.00 5.50 SO BUILDHGT WASTEHTR 5.50 5.50 5.50 5.50 17.00 17.00 SO BUILDHGT WASTEHTR 17.00 17.00 17.00 17.00 17.00 17.00 SO BUILDHGT WASTEHTR 17.00 17.00 17.00 17.00 17.00 5.50 SO BUILDWID WASTEHTR 20.14 24.55 28.21 31.02 100.38 100.21 SO BUILDWID WASTEHTR 97.00 90.85 85.58 94.40 100.35 103.25 SO BUILDWID WASTEHTR 103.01 99.65 93.25 84.03 72.25 15.12 SO BUILDWID WASTEHTR 20.14 24.55 28.21 31.02 100.38 100.21 SO BUILDWID WASTEHTR 97.00 90.85 85.58 94.40 100.35 103.25 SO BUILDWID WASTEHTR 103.01 99.65 93.25 84.03 72.25 15.12 SO BUILDLEN WASTEHTR 32.41 33.59 33.75 32.88 99.65 93.25 SO BUILDLEN WASTEHTR 84.03 72.25 58.76 71.86 83.01 91.64 SO BUILDLEN WASTEHTR 97.49 100.38 100.21 97.00 90.85 30.24 SO BUILDLEN WASTEHTR 32.41 33.59 33.75 32.88 99.65 93.25 SO BUILDLEN WASTEHTR 84.03 72.25 58.76 71.86 83.01 91.64 SO BUILDLEN WASTEHTR 97.49 100.38 100.21 97.00 90.85 30.24 SO XBADJ WASTEHTR -27.79 -27.77 -26.90 -25.22 -66.49 -73.20 SO XBADJ WASTEHTR -77.69 -79.82 -80.01 -91.64 -100.49 -106.29 SO XBADJ WASTEHTR -108.85 -108.11 -104.08 -96.89 -86.76 -3.28 SO XBADJ WASTEHTR -4.62 -5.82 -6.85 -7.66 -33.16 -20.05 SO XBADJ WASTEHTR -6.34 7.57 21.25 19.78 17.48 14.64 SO XBADJ WASTEHTR 11.36 7.73 3.87 -0.11 -4.09 -26.96 SO YBADJ WASTEHTR -2.50 -4.47 -6.31 -7.96 57.92 53.98 SO YBADJ WASTEHTR 48.39 41.34 34.12 24.85 14.83 4.36 SO YBADJ WASTEHTR -6.25 -16.67 -26.57 -35.68 -43.69 0.45 SO YBADJ WASTEHTR 2.50 4.47 6.31 7.96 -57.92 -53.98 SO YBADJ WASTEHTR -48.39 -41.34 -34.12 -24.85 -14.83 -4.36 SO YBADJ WASTEHTR 6.25 16.67 26.57 35.68 43.69 -0.45 SO BUILDHGT DIESLHTR 17.00 17.00 17.00 17.00 17.00 17.00 SO BUILDHGT DIESLHTR 17.00 5.20 5.20 5.20 5.20 5.20 SO BUILDHGT DIESLHTR 5.20 5.20 5.20 5.20 5.20 5.20 SO BUILDHGT DIESLHTR 17.00 17.00 5.20 5.20 5.20 5.20 SO BUILDHGT DIESLHTR 5.20 5.20 5.20 5.20 5.20 5.20 SO BUILDHGT DIESLHTR 5.20 5.20 5.20 5.20 5.20 5.20 SO BUILDWID DIESLHTR 71.86 83.01 91.64 97.49 100.38 100.21 SO BUILDWID DIESLHTR 97.00 16.18 15.36 16.65 17.44 17.69 SO BUILDWID DIESLHTR 17.41 16.60 15.28 13.50 11.31 8.78 SO BUILDWID DIESLHTR 71.86 83.01 15.04 16.29 17.04 17.28 SO BUILDWID DIESLHTR 16.99 16.18 15.36 16.65 17.44 17.69 SO BUILDWID DIESLHTR 17.41 16.60 15.28 13.50 11.31 8.78 SO BUILDLEN DIESLHTR 94.40 100.35 103.25 103.01 99.65 93.25 SO BUILDLEN DIESLHTR 84.03 11.31 8.78 11.23 13.34 15.04 SO BUILDLEN DIESLHTR 16.29 17.04 17.28 16.99 16.18 15.36 SO BUILDLEN DIESLHTR 94.40 100.35 17.69 17.41 16.60 15.28 SO BUILDLEN DIESLHTR 13.50 11.31 8.78 11.23 13.34 15.04 SO BUILDLEN DIESLHTR 16.29 17.04 17.28 16.99 16.18 15.36 SO XBADJ DIESLHTR -124.82 -134.19 -139.47 -140.52 -137.29 -129.90 SO XBADJ DIESLHTR -118.56 -4.60 -4.33 -6.51 -8.49 -10.21 SO XBADJ DIESLHTR -11.63 -12.69 -13.36 -13.63 -13.49 -13.41 SO XBADJ DIESLHTR 30.43 33.84 -13.84 -13.13 -12.03 -10.56 SO XBADJ DIESLHTR -8.77 -6.71 -4.45 -4.72 -4.85 -4.83 Page 4
building_data SO XBADJ DIESLHTR -4.66 -4.35 -3.91 -3.35 -2.69 -1.95 SO YBADJ DIESLHTR 43.74 29.39 14.16 -1.51 -17.13 -32.23 SO YBADJ DIESLHTR -46.35 5.40 5.73 5.65 5.40 4.99 SO YBADJ DIESLHTR 4.43 3.73 2.92 2.02 1.05 0.06 SO YBADJ DIESLHTR -43.74 -29.39 -2.69 -3.48 -4.17 -4.72 SO YBADJ DIESLHTR -5.14 -5.40 -5.73 -5.65 -5.40 -4.99 SO YBADJ DIESLHTR -4.43 -3.73 -2.92 -2.02 -1.05 -0.06 Page 5