MONTHYEARML24248A1712024-09-0303 September 2024 Proposed License Amendment Request - Temporary Service Water Supply to the Component Cooling Heat Exchangers IR 05000280/20240052024-08-26026 August 2024 Updated Inspection Plan for Surry Power Station, Units 1 and 2 (Report 05000280/2024005 and 05000281-2024005), Rev 1 ML24219A2372024-08-23023 August 2024 Issuance of Amendment Nos. 319 and 319, Adoption of TSTF-577, Rev. 1, Revised Frequencies for Steam Generator Tube Inspection, ML24207A0402024-08-21021 August 2024 Summary of July 17, 2024, Public Meeting - TS 3.7/3.14 AOT for SW Piping Maintenance IR 05000280/20240112024-08-13013 August 2024 Comprehensive Engineering Team Inspection Report 05000280/2024011 and 05000281/2024011 ML24164A0012024-08-12012 August 2024 Proposed Alternative Relief Request V-1 Inservice Testing of Pressure Isolation Valves (EPID l-2023-LLR-0060) IR 05000280/20240022024-08-0101 August 2024 Integrated Inspection Report 05000280/2024002 and 05000281/2024002 05000280/LER-2024-001, Troubleshooting Initiated Unknown Turbine Trip Feature in Control System2024-07-30030 July 2024 Troubleshooting Initiated Unknown Turbine Trip Feature in Control System ML24165A2782024-07-17017 July 2024 Issuance of Amendment Nos. 318 and 318, Reclassification of Regulatory Guide 1.97 Variable for Low Head Safety Injection ML24165A1232024-07-17017 July 2024 Proposed Alternative Relief Request P-1, P-2 Inservice Testing of Residual Heat and Containment Spray Pumps (EPID l-2023-LLR-0058) ML24190A4192024-07-0808 July 2024 Inservice Testing (IST) Program for Pumps and Valves Revised Sixth IST Interval Start Date and Updated Technical Specifications References for Alternative Request V-1 ML24179A2932024-07-0101 July 2024 Notification of Inspection and Request for Information for NRC Problem Identification and Resolution Inspection ML24178A2422024-06-25025 June 2024 2023 Annual Report of Emergency Core Cooling System (ECCS) Model, Changes Pursuant to the Requirements of 10 CFR 50.46 ML24177A2792024-06-20020 June 2024 Preparation and Scheduling of Operator Licensing Examinations ML24166A0622024-06-18018 June 2024 – Proposed Alternative Relief Request P-3, P-4 Inservice Testing of Boric Acid, Component Cooling Water Pumps ML24157A0542024-06-13013 June 2024 Audit Summary in Support of License Amendment Request for Proposed Reclassification of Low Head Safety Injection Flow Instrumentation Related to Regulatory Guide 1.97 ML24143A1622024-06-12012 June 2024 – Correction to Issuance of Amendment Nos. 297 and 280 and Surry Units 1 and 2, Correction to Issuance of Amendment Nos. 317 and 317, to Change Emergency Plan Staff Augmentation Times ML24170B0532024-06-10010 June 2024 DOM-NAF-2-P/NP-A, Revision 0.5, Reactor Core Thermal-Hydraulics Using the VIPRE-D Computer Code IR 05000280/20244032024-05-22022 May 2024 Information Request for the Cyber Security Baseline Inspection, Notification to Perform Inspection 05000280/2024403 and 05000281- 2024403 ML24141A2512024-05-20020 May 2024 Proposed License Amendment Request - Reclassification of Low Head Safety Injection Flow Indication Regulatory Guide 1.97 Variable - Supplemental Information ML24141A0482024-05-17017 May 2024 EN 56958_1 Ametek Solidstate Controls, Inc ML24136A2302024-05-13013 May 2024 Core 1 Cycle 33 Pattern Mdr Revision 0 ML24130A2032024-05-0909 May 2024 Proposed License Amendment Request Application to Revise Technical Specifications to Adopt TSTF-577, Revised Frequencies for Steam Generator Tube Inspections Supplemental Information ML24130A2492024-05-0909 May 2024 Submittal of Information in Support of Surry Power Station Unit 1 Thermal Shield Flexure Replacement Campaign ML24130A1192024-05-0707 May 2024 Inservice Test Program for Pumps and Valves Sixth Interval Update and Associated Relief and Alternative Requests - Response to Request for Additional Information Regarding Alternative Request V-1 ML24142A3852024-04-30030 April 2024 2023 Annual Radioactive Effluent Release Report IR 05000280/20240012024-04-30030 April 2024 Integrated Inspection Report 05000280-2024001 and 05000281-2024001 ML24122C6522024-04-30030 April 2024 Annual Radiological Environmental Operating Report ML24122B3032024-04-29029 April 2024 Associated Independent Spent Fuel Storage Installation, Revision to Emergency Plan Report of Change IR 05000280/20244022024-04-29029 April 2024 Security Baseline Inspection Report 05000280/2024402 and 05000281/2024402 ML24115A1952024-04-24024 April 2024 Notification of Surry Power Station Comprehensive Engineering Team Inspection - U.S. NRC Inspection Report 05000280/2024011 and 05000281/2024011 ML24054A0142024-04-22022 April 2024 Issuance of Amendment Nos. 297 and 280, and Surry Power Station Unit Nos. 1 and 2, Issuance of Amendment Nos. 317 and 317, to Change Emergency Plan Staff Augmentation Times ML24108A1812024-04-15015 April 2024 Proposed License Amendment Request - Reclassification of Low Head Safety Injection Flow Indication Regulatory Guide 1.97 Variable Supplemental Information ML24095A2172024-04-12012 April 2024 – Review of the Spring 2023 Steam Generator Tube Inspection Report ML24088A2482024-03-26026 March 2024 Inservice Testing Program for Pumps and Valves Sixth Interval Update and Associated Relief and Alternative Requests- Response to Request for Additional Information ML24087A2082024-03-22022 March 2024 Proposed License Amendment Request Addition of Containment Limiting Condition for Operation and Surveillance Requirements ML24078A2642024-03-21021 March 2024 – Regulatory Audit in Support of License Amendment Request to Proposed Reclassification of Regulatory Guide 1.97 Variable for Low Head Safety Injection Flow Instrumentation ML24087A1522024-03-18018 March 2024 Annual Changes, Tests, and Experiments Report Regulatory Commitment Evaluation Report ML24023A5762024-03-0808 March 2024 Correction to Issuance of Amendment Nos. 315 and 315, Regarding Revised Emergency Plan for Relocation of the Technical Support Center IR 05000280/20230062024-02-28028 February 2024 Annual Assessment Letter for Surry Power Station, Units 1 and 2 - NRC Inspection Reports 05000280/2023006 and 05000281/2023006 ML24032A4712024-02-20020 February 2024 Exemption from Select Requirements of 10 CFR Part 73 - Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting ML24057A0612024-02-19019 February 2024 and Virgil C. Summer Power Nuclear Stations - Nuclear Property Insurance Coverage ML24051A1782024-02-19019 February 2024 Proposed License Amendment Request - Application to Revise Technical Specifications to Adopt TSTF-577, Revised Frequencies for Steam Generator Tube Inspections IR 05000280/20230042024-02-0909 February 2024 Integrated Inspection Report 05000280/2023004 and 05000281/2023004 IR 05000280/20244012024-02-0606 February 2024 Security Baseline Inspection Report 05000280/2024401, 05000281/2024401 and 07200002/2024401 ML23312A1922024-01-18018 January 2024 Issuance of Amendment Nos. 316 & 316 Regarding a Risk Informed Approach for Tornado Classification of the Fuel Handling Trolley Support Structure IR 05000280/20230102024-01-18018 January 2024 – Age Related Degradation Inspection Report 05000280-2023010 and 05000281-2023010 ML24003A9022024-01-0303 January 2024 Emergency Plan Revision - Relocation of the Technical Support Center (TSC) - Editorial Correction IR 05000280/20233012023-12-28028 December 2023 – NRC Operator License Examination Report 05000280/2023301 and 05000281/2023301 ML23283A3052023-12-20020 December 2023 Review of Appendix F to DOM-NAF2, Qualification of the Framatome ORFEO-GAIA and ORFEO-NMGRID CHF Correlations in the Dominion Energy VIPRE-D Computer Code (EPID L-2022-LLT-0003) (Nonproprietary) 2024-09-03
[Table view] |
Text
VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 May 1, 2013 United States Nuclear Regulatory Commission Serial No.13-264 Attention: Document Control Desk SPS LIC/CGL R0 Washington, DC 20555-0001 Docket No. 50-280 50-281 License No. DPR-32 DPR-37 VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNITS 1 AND 2 REQUEST FOR APPROVAL TO USE A SUBSEQUENT AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) CODE EDITION AND ADDENDA FOR EXAMINATION CATEGORIES B-L-1 AND C-B IN THE FOURTH INSERVICE INSPECTION (ISI) INTERVAL Pursuant to 10CFR50.55a(g)(4)(iv), Virginia Electric and Power Company (Dominion) requests NRC approval to use a subsequent ASME Code edition and addenda for the ASME Section XI, Examination Categories B-L-1 and C-B, in the fourth ISI interval for Surry Power Station Units 1 and 2. This request is consistent with NRC Regulatory Issue Summary 2004-12, "Clarification on Use of Later Editions and Addenda to the ASME OM Code and Section XI." NRC approval of the use of the later Code edition and addenda, as discussed in the Attachment, is requested by September 30, 2013 to support use of the later Code edition and addenda during the Surry Units 1 and 2 refueling outages in Fall 2013 and Spring 2014, respectively.
If you have any questions or require additional information, please contact Mrs. Candee Lovett at (757) 365-2178.
Very truly yours, N. L. Lane Site Vice President Surry Power Station Attachment - Request for Approval to Use a Subsequent ASME Code Edition and Addenda for Examination Categories B-L-1 and C-B in the Fourth ISI Interval Commitments made in this letter: None AC7-g-
Serial No.: 13-264 Docket No.: 50-280/281 Page 2 of 2 cc: U.S. Nuclear Regulatory Commission Region II Marquis One Tower 245 Peachtree Center Ave., NE Suite 1200 Atlanta, Georgia 30303 NRC Senior Resident Inspector Surry Power Station Ms. K. R. Cotton NRC Project Manager U. S. Nuclear Regulatory Commission One White Flint North Mail Stop 0 8G-9A 11555 Rockville Pike Rockville, Maryland 20852 Dr. V. Sreenivas NRC Project Manager U. S. Nuclear Regulatory Commission One White Flint North Mail Stop 0 8G-9A 11555 Rockville Pike Rockville, Maryland 20852
Serial No.: 13-264 Docket No.: 50-280/281 ATTACHMENT Request for Approval to Use a Subsequent ASME Code Edition and Addenda for Examination Categories B-L-1 and C-B in the Fourth ISI Interval Surry Power Station Units I and 2 Virginia Electric and Power Company (Dominion)
Serial No.: 13-264 Docket No.: 50-280/281 Attachment Page 1 of 2 Request for Approval to Use a Subsequent American Society of Mechanical Engineers (ASME) Code Edition and Addenda for Examination Categories B-L-1 and C-B in the Fourth Inservice Inspection (ISI) Interval Virginia Electric and Power Company (Dominion) requests NRC approval to use a subsequent ASME Code edition and addenda for the ASME Section Xl, Examination Categories B-L-1 and C-B, in the fourth ISI interval for Surry Power Station Units 1 and 2. This request is consistent with NRC Regulatory Issue Summary 2004-12, "Clarification on Use of Later Editions and Addenda to the ASME OM Code and Section Xl."
- 1. ASME Code Component(s) Affected The affected ASME Section Xl components are the Reactor Coolant Pump (RCP) casing welds (B-L-l) and the Residual Heat Removal (RHR) Heat Exchanger Reinforcement Plate Welds to Vessel (C-B).
- 2. Applicable Code Edition and Requirements The current ASME Section Xl Code of record for the fourth ISI interval for Surry Power Station Units 1 and 2 is the 1998 Edition, including 2000 Addenda.
- 3. Proposed Subsequent Code Edition and Requirements The subsequent Code edition and addenda proposed for the fourth interval of the ISI Program, Examination Categories B-L-1 and C-B, are ASME Section Xl, 2007 Edition, including 2008 Addenda. The 2008 Addenda of Section Xl has been incorporated into the regulations by reference, as published in the Federal Register on June 21, 2011 (76 FR 36232), and became effective July 21, 2011.
ASME Category B-L-1 welds were removed in the ASME Section Xl, 2007 Edition, 2008 Addenda because experience has not identified any failures in RCP casings.
The requirement for performing these examinations results in unnecessary radiation exposure for non-destructive examination (NDE) personnel.
Flaw Acceptance Standards for Class 2 austenitic Pressure Retaining Welds of Nozzles in Vessels (ASME Category C-B) exists in IWC-351 1, of the 2007 Edition, 2008 Addenda, "Standards for Examination Category C-B, Pressure Retaining
Serial No.: 13-264 Docket No.: 50-280/281 Attachment Page 2 of 2 Welds of Nozzles," by referring to Table IWB-3514.2. Acceptance criteria do not exist for the RHR Heat Exchangers using the current ASME Code Edition and Addenda of record for Surry Units 1 and 2.
Therefore, Dominion proposes to use the 2007 Edition through the 2008 Addenda for the Category B-L-1 welds and for Paragraph IWC-3511 in its entirety and with all associated references for the RHR Heat Exchanger C-B welds in the fourth ISI interval for Surry Units 1 and 2.
- 4. Related Requirements For the portion of the subsequent Code edition and addenda to be used, there are no related requirements, modifications, or limitations listed in 10CFR50.55a that apply to Paragraph IWC-3511 or Examination Category B-L-1, which was deleted from the proposed code edition and addenda.
- 5. Duration of Use of Proposed Subsequent Code Edition and Requirements This request is applicable for the remainder of the fourth 10-year ISI interval for Unit 1, which is scheduled to end December 13, 2013 (after the Fall 2013 refueling outage), and for Unit 2, which is scheduled to end May 9, 2014.
- 6. Precedent Similar approval for use of a subsequent ASME Code edition and addenda for Examination Category B-L-1 was requested by Palo Verde Nuclear Generating Station Units 1, 2, and 3 in a letter, dated 12/29/2011,
Subject:
Request for Approval to Use a Subsequent ASME Code Edition and Addenda for Examination Categories B-L-1, B-M-1, and C-G in the Third ISI Interval. Approval was granted by an NRC letter, dated 9/18/2012,