NUREG 1307 Public Meeting Revised Table A-4
ML12312A419
Person / Time
Site: Braidwood  Constellation icon.png
Issue date: 11/07/2012
From:
NRC/NRR/DIRS/IFIB
To:
Simpson, Jo Ann, 301-415-8388
References
NUREG-1307, Rev 15
Download: ML12312A419 (3)


Text

Class A, B, C & GTCC Waste Disposal Processed Waste Disposal PLANT TYPE CAPACITY (MWe)

METHOD DOCKET NO.

ADAMS NO.2 Volume (Thousands ft3)

Volume (Thousands ft3)

Braidwood 1:

PWR 1178 50-456 ML100120241 - 01/11/2010 Scenario 1 DECON 114 192 Scenario 2 SAFSTOR 106 223 Braidwood 2:

PWR 1152 50-457 ML100120241 - 01/11/2010 Scenario 1 DECON 114 192 Scenario 2 SAFSTOR 106 223 Byron 1:

PWR 1164 50-454 ML093210130 - 11/16/2009 Scenario 1 DECON 115 189 Scenario 2 SAFSTOR 107 222 Byron 2:

PWR 1136 50-455 ML093210130 - 11/16/2009 Scenario 1 DECON 115 189 Scenario 2 SAFSTOR 107 222 Columbia Generating Station (PNNL Study)b BWR 1100 DECON 50-397 534 Not applicable Cooper:

BWR 830 50-298 ML083580119 - 12/15/2008 Scenario 1 2014 DECON 239 320 Scenario 2 2014 SAFSTOR 229 385 Diablo Canyon 1:

PWR 1122 50-275 ML050960544 - 02/12/2002 Scenario 1 DECON 116 Not available Scenario 2 SAFSTOR 102 Not available Diablo Canyon 2:

PWR 1118 50-323 ML050960544 - 02/12/2002 Scenario 1 SAFSTOR 110 Not available Scenario 2 DECON 124 Not available Duane Arnold:

BWR 580 50-331 ML100540029 - 01/27/2010 Scenario 1 DECON 401 Not available Scenario 2 SAFSTOR 401 Not available DOCUMENTATION FOR THE 2012 UPDATE OF NUREG-1307, REVISION 15, "REPORT ON WASTE BURIAL CHARGES"1 Total Volume of Waste Generated Percent of Processed Waste Percent of Direct Disposal (Direct + Vendor Disposal)

(Vendor Disposal Option)

(Direct Disposal) 306 62.74%

37.26%

329 67.88%

32.12%

306 62.74%

37.26%

329 67.88%

32.12%

304 62.17%

37.83%

329 67.57%

32.43%

304 62.17%

37.83%

329 67.57%

32.43%

559 57.25%

42.75%

614 62.70%

37.30%

534 Not available 100.00%

110 Not available 100.00%

124 Not available 100.00%

116 Not available 100.00%

102 Not available 100.00%

401 Not available 100.00%

401 Not available 100.00%

Class A, B, C & GTCC Waste Disposal Processed Waste Disposal PLANT TYPE CAPACITY (MWe)

METHOD DOCKET NO.

ADAMS NO.2 Volume (Thousands ft3)

Volume (Thousands ft3)

Hope Creek BWR 1061 SAFSTOR ML091820277 - 06/23/2009 228 233 Kewaunee:

PWR 556 DECON 50-305 ML091880777 - 06/16/2006 97 13 LaSalle 1:

BWR 1118 50-373 ML092400244 - 08/27/2009 Scenario 1 DECON 171 552 Scenario 2 SAFSTOR 118 659 LaSalle 2:

BWR 1120 50-374 ML092400244 - 08/27/2009 Scenario 1 DECON 191 606 Scenario 2 SAFSTOR 136 713 Monticello BWR 572 DECON 50-263 ML0613806380 - 05/05/2006 100 291 Oyster Creek:

BWR 619 50-219 ML041130434 - 04/14/2004 Scenario 1 DECON 310 386 Scenario 2 SAFSTOR 266 457 Palisades PWR 778 SAFSTOR 50-255 ML062840446 - 10/10/2006 169 326 Pilgrim BWR 685 SAFSTOR 50-293 ML082170672 - 07/16/2008 199 409 Prairie Island 1 PWR 551 DECON 50-282 ML082260425 - 08/08/2008 110 55 Prairie Island 2 PWR 545 DECON 50-306 ML082260425 - 08/08/2008 110 55 Salem 1 PWR 1174 DECON 50-272 ML081050556 - 04/07/2008 105 73 Salem 2 PWR 1130 DECON 50-311 ML081050556 - 04/07/2008 113 74 Three Mile Island 1:

PWR 819 50-289 ML091170630 - 02/11/2009 Scenario 1 DECON 223 180 Scenario 2 SAFSTOR 186 248 Trojan (PNNL Study)a PWR 1130 DECON 291 Not applicable Vermont Yankee:

BWR 620 50-271 ML080430658 - 02/06/2008 Scenario 1 DECON 334 340 Scenario 2 SAFSTOR 349 347 DOCUMENTATION FOR THE 2012 UPDATE OF NUREG-1307, REVISION 15, "REPORT ON WASTE BURIAL CHARGES"1 Total Volume of Waste Generated Percent of Processed Waste Percent of Direct Disposal (Direct + Vendor Disposal)

(Vendor Disposal Option)

(Direct Disposal) 461 49.46%

723 76.35%

23.65%

110 11.42%

88.58%

25.58%

797 76.04%

23.96%

849 83.98%

16.02%

777 84.81%

15.19%

495 65.83%

34.17%

696 55.50%

44.50%

723 63.15%

36.85%

165 33.33%

66.67%

608 67.24%

32.76%

60.36%

403 44.68%

55.32%

165 33.33%

66.67%

178 40.92%

59.08%

49.52%

696 49.91%

50.09%

434 57.20%

42.80%

291 Not available 100.00%

50.54%

674 50.48%

187 39.64%

391 74.42%

LLW Volume (ft3)

Full Service Disposal Facility Percent of Total Volume Nuclear Power Plant Reactor Type Reactory Capacity (Mwe)

Plant Docket Number

Reference:

ADAMS Number - Date 1 Decommissioning Scenario Vendor Processed/

Recycled Clive, Utah Disposal Facility Class A Class B Class C Greater Than Class C Total Vendor Direct Disposal Full Service Direct Disposal Braidwood 1 PWR 1178 50-456 ML100120241 - 01/11/2010 DECON 192,800 102,300 0

4,050 459 505 300,100 64.2%

35.6%

1.5%

Delayed DECON 215,600 89,700 0

3,130 459 505 309,400 69.7%

30.2%

1.2%

SAFSTOR 216,600 100,700 0

2,630 470 505 320,900 67.5%

32.3%

1.0%

Braidwood 2 PWR 1152 50-457 ML100120241 - 01/11/2010 DECON 190,900 112,300 0

3,960 459 505 308,100 62.0%

37.9%

1.4%

Delayed DECON 229,200 89,800 0

3,130 459 505 323,100 70.9%

28.9%

1.1%

SAFSTOR 230,300 100,300 0

2,630 470 505 334,200 68.9%

30.9%

0.9%

Byron 1 PWR 1164 50-454 ML093210130 - 11/16/2009 DECON 192,800 106,200 0

4,050 459 505 304,100 63.4%

36.4%

1.5%

Delayed DECON 215,600 93,100 0

3,130 459 505 312,800 68.9%

30.9%

1.1%

SAFSTOR 217,400 103,500 0

2,630 470 505 324,500 67.0%

32.9%

1.0%

Byron 2 PWR 1136 50-455 ML093210130 - 11/16/2009 DECON 186,000 112,700 0

3,960 459 505 303,700 61.2%

38.6%

1.5%

Delayed DECON 225,600 89,900 0

3,130 459 505 319,600 70.6%

29.3%

1.1%

SAFSTOR 227,300 100,000 0

2,630 470 505 330,900 68.7%

31.2%

0.9%

Cooper BWR 830 50-298 ML083580119 - 12/15/2008 2014 DECON 319,800 232,900 0

3,880 976 508 558,000 57.3%

42.6%

0.9%

2014 Delayed DECON 384,300 206,400 0

1,380 344 508 592,900 64.8%

35.1%

0.3%

2014 SAFSTOR 384,700 226,300 0

1,380 344 508 613,200 62.7%

37.2%

0.3%

2034 DECON 319,800 232,900 0

3,650 1,205 508 558,000 57.3%

42.6%

0.9%

2034 Delayed DECON 384,300 198,700 0

4,110 470 508 588,100 65.3%

34.6%

0.8%

2034 SAFSTOR 384,700 226,000 0

1,250 470 508 612,900 62.8%

37.2%

0.3%

Diablo Canyon 1 PWR 1122 50-275 ML050960544 - 02/12/2002 DECON NA2 0

98,652 16,260 574 604 NA2 NA2 NA2 100.0%

SAFSTOR NA2 0

93,981 7,050 584 604 NA2 NA2 NA2 100.0%

Diablo Canyon 2 and Common PWR 1118 50-323 ML050960544 - 02/12/2002 DECON NA2 0

107,868 15,270 574 604 NA2 NA2 NA2 100.0%

SAFSTOR NA2 0

101,957 7,310 584 604 NA2 NA2 NA2 100.0%

Duane Arnold BWR 580 50-331 ML100540029 - 01/27/2010 DECON 0

395,500 0

3,220 1,365 823 400,900 0.0%

99.8%

1.1%

SAFSTOR 0

398,800 0

2,100 2,015 0

402,900 0.0%

100.0%

1.0%

Delayed DECON 0

395,600 0

3,220 975 823 400,600 0.0%

99.8%

1.0%

Delayed SAFSTOR 0

398,700 0

2,400 1,625 0

402,700 0.0%

100.0%

1.0%

Hope Creek BWR 1061 ML091820277 - 06/23/2009 SAFSTOR 233,100 98,000 104,111 20,950 918 851 457,900 50.9%

48.9%

27.5%

Kewaunee PWR 556 50-305 ML091880777 - 06/16/2006 DECON 12,700 71,000 21,967 1,690 1,299 168 108,800 11.7%

88.2%

22.9%

Delayed DECON 12,700 71,000 21,967 1,690 1,299 168 108,800 11.7%

88.2%

22.9%

LaSalle 1 BWR 1118 50-373 ML092400244 - 08/27/2009 DECON 552,400 160,700 0

5,150 1,435 671 720,300 76.7%

23.2%

0.9%

Delayed DECON 657,800 96,900 0

4,510 631 671 760,500 86.5%

13.4%

0.7%

SAFSTOR 659,500 112,000 0

1,750 652 671 774,600 85.1%

14.8%

0.3%

LaSalle 2 BWR 1120 50-374 ML092400244 - 08/27/2009 DECON 606,300 180,800 0

5,270 1,435 671 794,500 76.3%

23.6%

0.8%

Delayed DECON 710,900 115,500 0

4,510 631 671 832,200 85.4%

14.5%

0.6%

SAFSTOR 712,500 130,100 0

1,750 652 671 845,700 84.2%

15.7%

0.3%

Monticello BWR 572 50-263 ML061380638 - 05/05/2006 DECON 290,500 87,200 0

7,970 804 408 386,900 75.1%

24.8%

2.3%

Oyster Creek BWR 619 50-219 ML041130434 - 04/14/2004 DECON 386,300 227,800 64,220 11,820 631 411 691,200 55.9%

44.0%

11.1%

Delayed DECON 462,200 203,600 36,478 6,690 287 411 709,700 65.1%

34.8%

6.1%

SAFSTOR 456,600 221,900 32,733 6,410 287 411 718,300 63.6%

36.4%

5.5%

Palisades PWR 778 50-255 ML062840446 - 10/10/2006 SAFSTOR 325,800 113,200 38,469 3,770 115 495 481,900 67.6%

32.3%

8.8%

Pilgrim BWR 685 50-293 ML082170672 - 07/16/2008 SAFSTOR 408,600 183,400 0

3,310 287 480 596,100 68.5%

31.4%

0.6%

Prairie Island 1 PWR 551 50-282 ML082260425 - 08/08/2008 DECON 132,000 68,700 0

2,470 918 512 204,600 64.5%

35.2%

1.7%

Prairie Island 2 PWR 545 50-306 ML082260425 - 08/08/2008 DECON 156,600 80,000 0

2,470 918 512 240,500 65.1%

34.7%

1.4%

Salem 1 PWR 1174 50-272 ML081050556 - 04/07/2008 DECON 72,800 84,200 0

13,150 459 613 171,200 42.5%

57.1%

7.9%

Salem 2 PWR 1130 50-311 ML081050556 - 04/07/2008 DECON 74,400 91,500 0

13,170 459 613 180,100 41.3%

58.4%

7.6%

Three Mile Island 1 PWR 819 50-289 ML091170630 - 02/11/2009 DECON 179,900 215,900 0

4,890 517 580 401,800 44.8%

55.1%

1.3%

Delayed DECON 247,800 167,600 0

2,630 517 580 419,200 59.1%

40.7%

0.8%

SAFSTOR 248,300 181,100 0

2,820 517 580 433,400 57.3%

42.6%

0.8%

Vermont Yankee BWR 620 50-271 ML080430658 - 02/06/2008 2012 DECON 2017 340,000 322,500 0

4,070 574 466 667,600 50.9%

49.0%

0.7%

2032 DECON 2017 340,000 322,000 0

4,400 746 466 667,600 50.9%

49.0%

0.8%

2012 DECON 2057 340,000 322,500 0

4,070 574 466 667,600 50.9%

49.0%

0.7%

2032 DECON 2042 340,000 322,000 0

4,400 746 466 667,600 50.9%

49.0%

0.8%

2012 SAFSTOR 2017 346,300 333,800 0

1,130 230 466 681,900 50.8%

49.2%

0.2%

2032 SAFSTOR 2017 346,300 329,700 0

2,750 605 466 679,800 50.9%

49.0%

0.5%

2012 SAFSTOR 2057 347,500 342,300 0

1,130 230 466 691,600 50.2%

49.7%

0.2%

2032 SAFSTOR 2042 347,500 340,900 0

1,130 230 466 690,300 50.3%

49.6%

0.2%