ML070730027

From kanterella
Jump to navigation Jump to search
Oak Ridge Institute for Science and Education - Letter Report for 18 Water Samples from the Vicinity of the Braidwood Nuclear Generating Station, Braidwood, Illinois (Inspection Report No. 050-00456/2007-003) (Rfta No.06-001)
ML070730027
Person / Time
Site: Braidwood 
Issue date: 03/07/2007
From: Condra D
Oak Ridge Institute for Science & Education
To: Snell W
Division of Nuclear Materials Safety III
References
FOIA/PA-2010-0209, IR-07-003, RFTA 06-001 IR-07-003
Download: ML070730027 (5)


Text

OAK RIDQE INSTITUTE FOR SCIENCE AND EDUCATION hlarch 7, 2007 llr. Wiham Snell L S. Nuclear Regulatory Commssion Regon I11 3133 W'arrenvdle Road 1.tslc. IL 60532-135 1

SUBJECT:

LETTER REPORT FOR 18 WATER SAMPLES FROM T H E VICINITY OF T H E BRAIDWOOD NUCLEAR GENERATING STATION, BRAIDWOOD, ILLINOIS

[INSPECTION REPORT NO. 050-00456/2007-0031 (RFTA NO.06-001)

Dear hlr. Snell:

'l'he Oak Ridge Institute for Science and Education (ORISE) received 18 water samples associated nith the Braidwood Generating Station on February 5, 2007. The samples were analyzed for tritium to a n average minimum detectable concentration of 180 pCi/L using a liquid scintillation analyzer. 'I'he chain-of-custody iden tified three water samples to be analyzed by gamma spectroscopy (GS). The sample identifications and collection data are presented in Table 1. The G S data are prcscntcd in 'l'able

2. The tritium data are presented in Table 3. The pertinent procedure references arc provided in the specific tables.

OKISE's Quality Control (QC) requirements were met for these analyses. The QC tiles arc arailablc for your review upon request.

My contact information IS listed below. You may also contact \\Vadc Irey at 865.576.9181 nith any c]ucsuons or comments.

Sincerely, y - 4 P&

f2 1Me Condra, hlanager I >aboratory l<llC:K'PI:ar C.

T. Carter, Nh.ISS/DK%.IEP 7518 E. Abelquist, ORISE E. Knox-Dawn, NRC/NhlSS/T\\XFN 8;\\23

s. I k k, ORISE Fde 1732 Distribution approval and concurrence :

Technical Aianagement Team hiember Quality hianager Initials

\\'oice: 865.241.32-12 Fax: 865241.3248 E-mail: Dalc.(;ondraOorau.or~

RECEIVE0 flAR

TABLE 1 NRC Region I11 Collection Collection Date ORISE Sample ID Sample ID Time 1732W0014 BD-07-1-14 12/20/06 NDI' 1732W0015 BD-07-1-15 12/20/06 NDP 1732W0016 BD-07-1-16 12/12/06 NDP 1732W0017 BD 1 - 17 01/16/07 NDI' 1732W0018 BD-07-1-18 01 / 17/07 NDl'

'No Jiti pro! dcd SAMPLE IDENTIFICATIONS AND COLLECTION DATA BRAIDWOOD NUCLEAR GENERATING STATION BRAIDWOOD, ILLINOIS

TABLE 2 ORISE Sample ID 1732W0005 1 7 32wOO 1 0 1732W0015 CONCENTRATIONS OF SELECTED GAMMA EMITTING RADIONUCLIDES IN SELECTED WATER SAMPLES BY GAMMA SPECTROSCOPY CP1, REVISION 15 BRAIDWOOD NUCLEAR GENERATING STATION BRAIDWOOD, ILLINOIS NRC Region I11 Radionuclide Concentrationsa (pCi/L)

Sample ID CO-58 CO-60 CS-134 cs-137 BD-07-1-05

-3.4 t 4.8b 2.4 k 3.0

-0.1 k 3.5 2.8 k 3.0 BD-07-1-10

-4.3 ? 4.5

-0.6 ? 3.1 0.3

& 3.3

-0.1 k 3.0 BD-07-1-15

-0.8 ? 3.2 0.1 k 2.3 0.0'

? 2.5 2.0 5 2.2

  • 'l'hc r.ingc (if h[lXs for thc sclectcd radionuclidcs IS 3 5 pC1/1. to 7.8 pCi/I,.

I'Clnccrt.iin[ics rcprrsciit thc 05"'0 confidence IcvcI, bascd on total propaptcd unccrtaintlcs

TABLE 3 1732W0003 1732W0004 1732W0005 1732W0006 CONCENTRATIONS OF TRITIUM IN WATER SAMPLES BY LIQUID SCINTILLATION ANALYSIS AP2, REVISION 15; CP4, REVISION 3 BRAIDWOOD NUCLEAR GENERATING STATION BRAIDWOOD, ILLINOIS BD-07-1-03

-10 k

100 180 BD-07-1-04 50 k

100, 180 BD-07-1-06 0'

k 100 180 BD-07-1-05 40 5

100 180 NRC Region 111 Tritium Concentrations, TPUs, Sample ORISE ID I Sample ID I

and MDCs" (pCi/L) 1732W0007 1732W0008 1732W0009 1732W0001 I

BD-07-1-01 I

90 k

l l O b 180 BD-07-1-07

-30 t

100 180 BD-07-1-08 50 k

100 180 BD-07-1-09 90 t

110 180 1 7 3 2 W O 0 ~ 1 B D ~ 1

-OF 1-10 t

100 180 1732W0010 1732W0011 1732W0012 1732LV0013

~~

BD-07-1-10 80 k

100 180 BD-07-1-11 20 5

100 180 BD 1 - 1 2 20 t

100 180 BD-07-1-13 30 5

100 180

~~

~~

1732W0014 1732W0015 1732W0016 1732W0017

~

BD-07-1-14

-1 0 5

100 180 BD-07-1-15 60 k

100 180 BD-07-1-16 10 2

100 180 BD-07-1-17 70 5

100 180

~~~

~~

~

1732W0018 I BD-07-1-18 1

250 2

110 180

~~

~~

~

'XI1X:s arc after the comma.

"llnccrtainocs rcprcscnt the 95"b confidence Icvcl, based on total propagatcd unccrtantics

'Zero values arc duc to rounding.