ML12088A404

From kanterella
Jump to navigation Jump to search
Entergy Pre-Filed Hearing Exhibit ENT000049, 0700.104-17, Rev. 2, Indian Point Energy Center Unit 3, FAC System Susceptibility Evaluation (SSE)
ML12088A404
Person / Time
Site: Indian Point  
Issue date: 10/14/2011
From: Doremus R
CSI Technologies
To:
Entergy Nuclear Operations, Atomic Safety and Licensing Board Panel
SECY RAS
Shared Package
ML12088A381 List:
References
RAS 22101, 50-247-LR, 50-286-LR, ASLBP 07-858-03-LR-BD01 0700.104-17, Rev 2
Download: ML12088A404 (200)


Text

ENT000049 Submitted: March 28, 2012 (S I TECHNOLOGIES, INC.

Consulting Engineers REPORT APPROVAL COVER SHEET Document

Title:

Indian Point Energy Center Unit 3 FAC System Susceptibility Evaluation (SSE)

Document No.:

0700.104-17 Client:

Entergy Nuclear Project No.:

0705.111 This report has been prepared in accordance with Section 4.4 of the CSI Quality System Manual, Revision 2.

Revision:

2 (For-Use) 200 pages Prepared: ~us (eSI)

Verified:

tJ,..z--~

Brant D. Yung I)

Approved: ~_

yan D. Doremus (CSI)

Date: /0/1:> If{

Date: IO/J?J/J I I

Date: I Q /1 Lf. 11 \\

i Approved: _________________ Date: ____ -'-

Ian D. Mew (IPEC)

(S I TECHNOLOGIES, INC.

Project Number:

Project Name:

Client:

Document

Title:

Document Number:

Rev.

Date 0

1211112009 1

1122/2010 2

1011412011 Revision Control Sheet 0705.111 IPEC FAC Support 2011 Entergy Nuclear Indian Point Energy Center Unit 3 FAC System Susceptibility Evaluation (SSE) 0700.104-17 Description of Changes Initial Issue-For Use Revision to incorporate new system list - For Use Revision to incorporate replacement history - For Use Consulting Engi1Jeers CSI Client Approval Approval B. Trudeau I. Mew B. Trudeau I. Mew f?. O"~J

Indian Point Energy Center Unit 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17 Revision 2 Issued For-Use October 14, 2011 prepared for:

Entergy Nuclear Indian Point Energy Center 450 Broadway Buchanan, NY 10511 prepared by:

CSI TECHNOLOGIES, INC.

1 Douglas Ave., Suite 300 Elgin, IL 60120

Copyright © 2011 CSI Technologies, Inc. All rights reserved.

The information in this document belongs to CSI Technologies, Inc. It may not be used, reproduced, or disclosed without the written approval of CSI Technologies, Inc.

Disclaimer and Limitation of Liability CSI Technologies, Inc. (CSI) has made efforts to ensure the accuracy and completeness of the information in this document. However, CSI makes no warranties of any kind (whether express, implied, or statutory) with respect to the information contained herein. CSI assumes no liability to any party for any loss or damage (whether direct or indirect) caused by any errors, omissions, or statements of any kind contained in this document.

Further, CSI assumes no liability arising from the application or use of the product, service, or results described herein and specifically disclaims any representation that the products, services, or results described herein do not infringe upon any existing or future intellectual property rights. Nothing herein grants the reader any license to make, use, or sell equipment or products constructed in accordance with this document. Finally, all rights and privileges related to any intellectual property right described herein are vested in the patent, trademark, or service mark owner, and no other person may exercise such rights without express permission, authority, or license secured from the patent, trademark, or service mark owner.

Trademarks CSI Technologies, Inc., the CSI logo, and other trademarks, service marks, and logos are registered or unregistered trademarks of CSI and its subsidiaries in the United States and in foreign countries. Other trademarks and service marks in this document are the property of their respective owners.

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Revision 2 Page 1 of 19 Table of Contents 1.

INTRODUCTION............................................................................................................................................... 2

2.

PURPOSE............................................................................................................................................................ 3

3.

SCOPE.................................................................................................................................................................. 4

4.

ASSUMPTIONS.................................................................................................................................................. 5

4.1.GENERAL ASSUMPTIONS................................................................................................................................ 5

4.2.SYSTEM, SUBSYSTEM, AND LINE SPECIFIC ASSUMPTIONS.............................................................................. 5

5.

METHODOLOGY.............................................................................................................................................. 7

5.1.SUSCEPTIBILITY EXCLUSION CRITERIA.......................................................................................................... 8

5.2.SUSCEPTIBLE NON-MODELED (SNM) CRITERIA.......................................................................................... 10

6.

RESULTS........................................................................................................................................................... 13

6.1.SYSTEM SUSCEPTIBILITY EVALUATION........................................................................................................ 13

6.2.SUBSYSTEM SUSCEPTIBILITY EVALUATION.................................................................................................. 13

6.3.LINE SUSCEPTIBILITY EVALUATION............................................................................................................. 14

6.4.COLOR-CODED FLOW DIAGRAMS................................................................................................................. 16

6.5.REVISION HISTORY....................................................................................................................................... 16

6.6.INDUSTRY FAC EXPERIENCE TABLE............................................................................................................ 16

6.7.FAC-SUSCEPTIBLE LINES CONTAINING ORIFICES........................................................................................ 16

7.

REFERENCES.................................................................................................................................................. 18

APPENDIX A:

SYSTEM SUSCEPTIBILITY EVALUATION REPORT APPENDIX B:

SUBSYSTEM SUSCEPTIBILITY EVALUATION REPORT APPENDIX C:

LINE SUSCEPTIBILITY EVALUATION REPORT APPENDIX D:

REVISION HISTORY ATTACHMENT A: INDUSTRY FAC EXPERIENCE TABLE ATTACHMENT B: REFERENCED CORRESPONDENCE AND COMMUNICATIONS

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Revision 2 Page 2 of 19

1.

Introduction Flow-Accelerated Corrosion (FAC) is a form of material degradation that results in thinning of the inside pipe wall in carbon steel piping and fittings under certain flow and chemistry conditions. If undetected, FAC may result in piping rupture and subsequent fatalities, injuries, equipment damage, unplanned plant shutdown, and transients that pose undesirable challenges to plant operators. Consequently, all US nuclear plants, including Indian Point, have FAC programs in place to detect and mitigate FAC before piping failure in accordance with Generic Letter 89-08 [7.1].

An effective FAC program includes three key elements: the System Susceptibility Evaluation (SSE), which defines and controls the program scope; the CHECWORKS computer model, which predicts wear rates for every modeled component; and the Susceptible Non-Modeled (SNM) Program, which prioritizes non-modeled but susceptible lines according to FAC potential.

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Revision 2 Page 3 of 19

2.

Purpose This document contains the development and results of an FAC System Susceptibility Evaluation (SSE) for Indian Point Energy Center Unit 3. Each plant system, subsystem, and line is classified as either susceptible or non-susceptible to FAC. Susceptible piping forms the scope of the Indian Point FAC program, while non-susceptible piping is excluded from the FAC program. Susceptible piping is further categorized as either modelable in the EPRI computer program CHECWORKS Steam/Feedwater Application (SFA) or non-modelable. Susceptible Non-Modeled (SNM) piping falls outside the capabilities of CHECWORKS SFA.

The purpose of this document is to:

  • Define the scope of the Flow-Accelerated Corrosion (FAC) program.
  • Identify all plant lines to be modeled in the EPRI computer program CHECWORKS Steam/Feedwater Application (SFA).
  • Identify all plant lines that form the scope of the Susceptible Non-Modeled (SNM) program.

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Revision 2 Page 4 of 19

3.

Scope The scope of this System Susceptibility Evaluation is all plant piping, which includes piping in all systems, subsystems, and lines. This document reflects the current operating status of the plant. Periodic review and update of this document is recommended by EPRIS Recommendations for an Effective Flow-Accelerated Corrosion Program, NSAC 202L [7.2].

Section 4 of this document contains a record of all assumptions made. Section 5 describes the methodology employed in this analysis. The results obtained are documented in Section 6 and in the Appendices. Finally, Section 7 includes a list of all references used in this analysis.

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Revision 2 Page 5 of 19

4.

Assumptions 4.1.

General Assumptions The following assumptions apply to all plant systems, subsystems, or lines.

4.1.1.

Piping with nominal pipe size less than or equal to 2 is assumed to be socket welded. Likewise, lines over 2 in diameter are assumed butt-welded.

4.1.2.

Wherever pipe class is unknown, carbon steel material is assumed.

4.1.3.

If a portion of a system, subsystem, or line is susceptible, then the entire system, subsystem, or line is considered susceptible. An exception is made for lines where valves are the only susceptible components. Since valves are inspected by the Preventative Maintenance or Corrective Action programs, they are considered outside the FAC program.

4.1.4.

Lines on the Indian Point P&IDs [7.3] containing normally closed valves are assumed to operate less than 2% of the time. Likewise, lines containing valves that are normally open are assumed to operate greater than 2% of the time. This assumption is used when specific valve information is not found in the System Descriptions [7.4] or in correspondence with Indian Point plant personnel [7.5].

4.1.5.

It is assumed that no normally closed valves leak, unless confirmed otherwise by plant operating history.

4.1.6.

Lines that exist in non-susceptible systems or subsystems are excluded from further analysis on the system or subsystem level, respectively.

These lines may or may not appear in the Appendices.

4.2.

System, Subsystem, and Line Specific Assumptions Assumptions and susceptibility decisions made specifically for a single system, subsystem, or line appear in the Comments field of the Susceptibility Evaluation reports in the Appendices.

4.2.1.

Instrumentation, level control lines, and indicator lines are assumed to have insufficient flow to be susceptible to FAC.

4.2.2.

Floor drains, miscellaneous capped drain and vent lines, and miscellaneous vent lines to the atmosphere are assumed to have insufficient flow to be susceptible to FAC (or operate infrequently).

4.2.3.

Multiple line names are used for the same line in cases where susceptibility changed along the line and in cases where relationships to CHECWORKS are simplified by separating sections of lines.

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Revision 2 Page 6 of 19 4.2.4.

The supply and return headers to the OSB building, line numbers 3-UH-178 and 3-UH-177, are continued on a drawing that could not be located by Indian Point personnel [7.5.3]. It was concluded that the continuations of these lines, as well as any lines fed by these headers, should be considered FAC-susceptible until proven otherwise.

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Revision 2 Page 7 of 19

5.

Methodology The methodology employed in this analysis consisted of a number of successive steps.

Each step is explained in detail in the following sections. A flowchart of the methodology used is included in the Figure 5.1.

Each plant system, subsystem, and line was reviewed against FAC susceptibility criteria and CHECWORKS modelability criteria (as defined in Section 5.1 and Section 5.2) to determine its susceptibility category. If an entire system or subsystem was determined to be non-susceptible, a line-by-line review was not conducted; however, where that was not the case, each line was evaluated and categorized accordingly and individually.

Excluded No further evaluation Yes Can be Modeled in CHECWORKS SNM Program CHECWORKS Modeled No Yes Figure 5.1 Susceptibility Evaluation Methodology All Plant Systems Meets System Susceptibility Exclusion Criteria Excluded No further evaluation Yes No Determine Subsystem Susceptibility No Meets Subsystem Susceptibility Exclusion Criteria Meets Line Susceptibility Exclusion Criteria Excluded No further evaluation Yes Determine Line Susceptibility No

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Revision 2 Page 8 of 19 5.1. Susceptibility Exclusion Criteria The criteria used to determine susceptibility to FAC was taken from Section 4.2 of EPRI NSAC 202L [7.2]. Systems, subsystems, and/or lines are not considered susceptible to FAC if one or more of the conditions discussed below apply.

5.1.1. FAC Resistant Material Stainless steel or low-alloy steel with chromium content equal or greater than 1.25% is FAC-resistant [7.2 and 7.6]. Lines or systems made or replaced with such materials are not sufficiently susceptible to FAC to warrant further analysis. It should be noted, however, that resistance to FAC does not ensure against other corrosion mechanisms such as cavitation or impingement. Therefore, even if components are replaced with FAC-resistant material, the root cause of wear should be determined before excluding the replaced components from the inspection program.

Wholesale replacement of a line with FAC resistant material would cause that line to be excluded from the FAC program. However, if one component on a line is susceptible, then the whole line was considered susceptible.

Piping material was obtained from the Piping Specifications [7.7], P&IDs

[7.3], and the Indian Point isometric drawings [7.8].

5.1.2. Superheated Steam Piping which transports superheated steam with no moisture content is classified as non-susceptible. According to EPRIs Recommendations for an Effective Flow-Accelerated Corrosion Program, FAC is known to occur only under flowing water or wet steam conditions, and has not been documented in superheated steam piping [7.2].

The PEPSE Model [7.9] was used as the primary source of operating condition information. Secondary information was found in the Piping Specification [7.7].

5.1.3. Single-Phase Piping at Low Temperature Piping with single-phase flow and an operating temperature below 200oF does not experience FAC and is classified as non-susceptible. No temperature exclusion exists for two-phase lines [7.2]. Other degradation mechanisms, such as cavitation, may occur at low temperatures but such mechanisms are outside the scope of this analysis.

Operating temperature was obtained from the PEPSE Model [7.9] as a first priority, followed by the operating conditions found in the Piping Specification [7.7].

5.1.4. Low Operating Frequency Piping that operates less than 2% of the plant operating time was deemed non-susceptible. In general, such piping does not experience the amount of flow required to make FAC a legitimate concern and is excluded from

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Revision 2 Page 9 of 19 further analysis in favor of piping with greater FAC susceptibility. Piping in this category includes lines with normally closed valves and those feeding or emerging from equipment which operate less than 2% of the plant operating time.

Exceptions to this rule are made when the operating frequency may be low, but the service is especially severe [7.2].

All lines excluded due to infrequent operation would be susceptible to FAC if operating frequency is increased above the 2% threshold.

Therefore, if operating frequency is increased, these lines should be reviewed for inclusion into the FAC Program.

Operating frequency was determined through information found in the System Descriptions [7.4], responses to questions posed to Indian Point personnel [7.5], and by valve position on the P&IDs [7.3]. See Assumption 4.1.4 for more details.

5.1.5. Combination Single-Phase Piping with Low Temperature and Operating Frequency This category is a derivative of the two previous susceptibility criteria described in Sections 5.1.3 and 5.1.4. It may be used for a system, subsystem, and/or a line that operates >2% of total plant operating time but only occasionally (<2% of the time) will the temperature of the single-phase fluid, within the piping, exceed 200°F. Thus, piping containing a single-phase flow that operates less than 2% of the time above 200°F is classified as non-susceptible to FAC.

5.1.6. Non-Water/Steam Piping Piping that transports fluids other than water or steam, such as air or oil, is not susceptible to FAC.

5.1.7. Dissolved Oxygen Concentration Lines containing water with high levels of dissolved oxygen (typically greater than 1000 ppb) are considered immune to FAC and can be excluded from further analysis [7.2]. Systems normally meeting this criterion include Service Water, Circulating Water, and Fire Protection.

5.1.8. Low or No Flow While instrumentation and/or sensing lines may operate continuously, they experience very limited fluid flow. Such piping does not experience the amount of flow required to make FAC a legitimate concern and is excluded from further analysis in favor of piping with greater FAC susceptibility.

5.1.9. Non-Piping Systems that do not contain piping (e.g. computer system) are excluded from the FAC program.

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Revision 2 Page 10 of 19 5.1.10. Piping Removed from Service Piping that has been removed from service and capped is excluded from the FAC program. Degradation mechanisms may occur in such piping, but for Flow-Accelerated Corrosion to occur, flow is required [7.2].

Table 5.1 provides a summary of the FAC susceptibility exclusion parameters discussed in this section. Also provided is the abbreviation used for each criterion.

Table 5.1 Susceptibility Exclusion Criteria Abbreviation Reason Description EM Material Excluded due to FAC-resistant Material EQ Superheated Excluded due to high steam Quality (superheated steam)

ET Single Phase, T<200°F Excluded due to Temperature EI Time <2%

Excluded due to Infrequent operation (note:

would be FAC susceptible if operated at a higher frequency)

EC Single Phase, T>200°F for time<2%

Excluded due to a Combination of infrequent operation above temperature threshold EW Non-water/steam Excluded due to no Water or steam present EO High D.O.

Excluded due to dissolved O2 content >1000 ppb EF Low or No Flow Excluded due to Low or No Flow EP Non-Piping Excluded due to no Piping components present ER Pipe Removed Excluded due to Removal of piping from service 5.2. Susceptible Non-Modeled (SNM) Criteria Each line that is not excluded due to criteria listed in Table 5.1 is determined to be susceptible to FAC. An explicit determination of suitability for CHECWORKS modeling was made for these lines. For each line that is susceptible but unsuitable for modeling, the basis for that determination was recorded. Lines are determined to be non-modelable in CHECWORKS if one or more of the conditions discussed below apply.

5.2.1. Weld Type Lines with socket-welded fittings are classified as non-modelable. Almost all small bore lines (less than or equal to 2 in diameter) are constructed using socket-welded fittings. The socket weld uses a fit-up gap of variable size. This gap can greatly impact turbulence in piping, which in turn has a

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Revision 2 Page 11 of 19 significant impact on wear rate. Since the size of the fit-up gap is unknown, CHECWORKS cannot accurately predict wear for socket-welded components [7.10].

For this analysis, all small bore lines were considered socket-welded and therefore non-modelable (see 4.1.1). In addition, the extremely large linear footage of small-bore lines and the often unknown thermodynamic conditions combine to make detailed modeling of small-bore piping inefficient and sometimes inaccurate.

5.2.2. Unknown Operating Conditions In cases where operating conditions cannot be accurately obtained or calculated, precise modeling cannot be performed. In addition to chemistry, CHECWORKS requires a value for flow, frequency of operation, and two thermodynamic values (pressure, temperature, quality, or enthalpy) to predict wear. The PEPSE Model was the primary source of flow and thermodynamic conditions [7.9]. Thermodynamic conditions were also obtained from the operating conditions found in the Piping Specification [7.7]. Operating frequency was determined by valve position and flow rate information on the P&IDs [7.3], from information found in System Descriptions [7.4], and through responses to questions posed to Indian Point personnel [7.5].

Where operating conditions were unknown or varied, the lines are classified as SNM.

5.2.3. Conditions outside CHECWORKS Modeling Capabilities Lines that operate with conditions outside of CHECWORKS modeling capabilities are considered SNM. For example, lines with entrained moisture or vent lines containing non-condensable gases are classified as non-modelable.

5.2.4. Visually Inspected Lines Lines that are visually inspected during outages do not require modeling.

For many plants, this criterion applies to the Turbine crossunder piping.

5.2.5. Localized FAC Susceptibility Lines that are classified as FAC susceptible only at a single location are deemed non-modelable. Examples include carbon steel nozzles and valves in a low alloy line.

5.2.6. High Steam Quality Lines that contain very high quality (but not superheated) steam are classified as SNM. Modeling such lines is of little value as CHECWORKS predictions would be trivial.

The PEPSE Model [7.9] was used as a primary source of steam quality.

The Pipe Specification [7.7] was used as a secondary source.

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Revision 2 Page 12 of 19 Table 5.2 provides a summary of the CHECWORKS model exclusion parameters discussed in this section. Also provided is the abbreviation used for each criterion.

Table 5.2 CHECWORKS Model Exclusion Criteria Abbreviation Reason Description NS Socket-welded Non-modeled due to Socket-welds NC Unknown conditions Non-modeled due to unknown or varying operating Conditions NM Conditions outside CHECWORKS modeling capabilities Non-modeled due to conditions outside CHECWORKS Modeling capabilities NV Visual inspections Non-modeled due to Visual inspections NL Localized FAC Non-modeled due to Localized FAC susceptibility NQ High Steam Quality Non-modeled due to high steam Quality resulting in CHECWORKS predictions of little value

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Revision 2 Page 13 of 19

6.

Results The following sections contain a description of the data found in the appendices.

6.1. System Susceptibility Evaluation The results of the System Susceptibility Evaluation appear in Appendix A, which lists all plant systems and classifies each as susceptible or non-susceptible to FAC. For those deemed non-susceptible, the reason for exclusion from the FAC program is provided. The following fields appear in this report.

6.1.1. System Code This field contains the common designation for the system.

6.1.2. System Name This field contains a brief description or name of the system.

6.1.3. Susceptible?

This field states if the system is FAC susceptible.

6.1.4. Exclusion Criteria (Excl. Crit.)

This field contains the reason why the system is non-susceptible to FAC (see Table 5.1).

6.1.5. Comments Pertinent information about the system appears in this field.

6.1.6. Reference References used in determining susceptibility appear in this field.

6.2. Subsystem Susceptibility Evaluation Susceptible systems were divided into subsystems by grouping lines of similar function. The results of the Subsystem Susceptibility Evaluation appear in Appendix B, where each subsystem included in a susceptible system is evaluated for its FAC susceptibility. For those deemed non-susceptible, the reason for exclusion from the FAC program is provided. The following fields appear in this report.

6.2.1. Subsystem Number This field contains the number of the subsystem, where a subsystem is a subset of the system piping with similar operating parameters. Subsystem names were created for this evaluation and include the unit number, common system designation and a sequential number in the following format.

A-BBBB-CC A

Unit Number BBBB System Abbreviation CC Sequential Number

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Revision 2 Page 14 of 19 Example: 3-BFD-01, 3-3EX-02, 3-5EST-01 6.2.2. Subsystem Name This field contains the name of the subsystem preceded by the system (represented by the system code) that it falls into.

6.2.3. Subsystem Boundary A description of the lines which are grouped in this subsystem is shown here.

6.2.4. Flow Diagram (P&ID)

This field lists the flow diagram(s) on which the subsystem is found.

6.2.5. FAC Susceptible? (FAC. Sus.?)

This field states if the subsystem is FAC susceptible.

6.2.6. Exclusion Criteria (Excl. Crit.)

This field contains the reason the subsystem is non-susceptible to FAC (see Table 5.1).

6.2.7. Comments Pertinent information about the subsystem appears in this field.

6.2.8. Reference References used in determining susceptibility appear in this field.

6.3. Line Susceptibility Evaluation Lines in FAC susceptible systems were placed into one of three categories:

  • Excluded lines (non-susceptible)
  • Susceptible lines to be modeled in CHECWORKS
  • Susceptible non-modeled (SNM) lines Appendix C contains the results of the line susceptibility evaluation for Indian Point Energy Center. Appendix C is organized into sections with Section A listing CHECWORKS modeled lines, Section B listing SNM program lines, and Section C listing excluded lines. For SNM lines, the reason for exclusion from the CHECWORKS model is provided. For excluded lines, the reason for exclusion from the FAC program is provided. Not every line in a non-susceptible subsystem was explicitly analyzed and therefore only selected lines will appear in the report (see Section 4.1.6).

The following fields appear in this report.

6.3.1. Line Number Indian Point does not maintain a complete piping line list. Therefore, line names needed to be created. The majority of main piping lines, depending

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Revision 2 Page 15 of 19 on susceptibility, were assigned a unique Line Number. The naming convention follows a format which includes unit number, system abbreviation, a sequential number, and, if necessary, a section designator used either for parts of the same line with different susceptibility characteristics or specifications or for preventing duplicate line names:

A-BBBB-CCC-D A

Unit Number BBBB System Abbreviation CCC Sequential Number D

Section Designator Examples: 3-2EX-019, 3-MS-093-A, 3-SB-020, 3-5EST-074-C 6.3.2. Size The diameter, in inches, of the majority of the line is listed here.

6.3.3. Flow Diagram (P&ID)

This field lists the flow diagram(s) on which the line is found.

6.3.4. Susceptibility Category (Sus. Cat.)

The susceptibility category is listed in this field. Table 6.1 defines the three susceptibility categories.

Table 6.1 Susceptibility Categories Abbreviation Category M

CHECWORKS Modeled S

Susceptible non-modeled (SNM)

E Excluded from the FAC program (non-susceptible) 6.3.5. Model Exclusion Criteria (Mod. Ex. Crit.)

This field appears only for SNM lines. It contains the reason each SNM line is not modeled in CHECWORKS (see Table 5.2).

6.3.6. Susceptibility Exclusion Criteria (FAC Ex. Crit.)

This field appears only for excluded lines. It contains the reason each excluded line is non-susceptible to FAC (see Table 5.1).

6.3.7. Comments Pertinent information about the line appears in this field.

6.3.8. Reference References used in determining susceptibility or modelability appear in this field.

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Revision 2 Page 16 of 19 6.3.9. Line Description This field contains a description of the line.

6.4. Color-Coded Flow Diagrams Flow diagrams of all FAC susceptible systems addressed in this document are included in the Color-Coded Flow Diagrams. The flow diagrams are color-coded based upon FAC susceptibility category and labeled to indicate line numbers.

Line numbers were added to the flow diagrams. See the Color-Coded Flow Diagrams Document 0700.104-19 for the color-code convention.

6.5. Revision History Changes made for each revision of this report are documented in Appendix D.

6.6. Industry FAC Experience Table Attachment A contains a table of important industry FAC events. This table was used as an aide in determining FAC susceptibility.

6.7. FAC-Susceptible Lines Containing Orifices As a subtask of the project, a list of FAC-susceptible lines containing orifices was gathered and is shown in Table 6.2 below.

Table 6.2 FAC Susceptible Lines Containing Orifices Line Number Line Description P&ID Coord.

3-AS-001 Aux Steam to RS-UH-1 9321-F-41443 E2 3-AS-003 Aux Steam to RS-HC-2 9321-F-41443 D5 3-AS-004 Aux Steam to RS-HC-4 9321-F-41443 D5 3-AS-005 Aux Steam to RS-HC-1 9321-F-41443 C5 3-AS-006 Aux Steam to RS-HX-1 9321-F-41443 D3 3-AS-007 Aux Steam to RS-HC-3 9321-F-41443 E5 3-AST-104 Aux Steam to and from AST-10 9321-F-27273 D6 3-AST-122 Aux Steam thru AST-12 to Cond Receiver 9321-F-27273 F4 3-AST-133 Aux Steam thru AST-21 to Cond Receiver 9321-F-27273 F5 3-AST-134 Aux Steam thru AST-20 to Cond Receiver 9321-F-27273 E4 3-AST-138 Aux Steam thru AST-13 9321-F-27273 D5 3-AST-139 Aux Steam thru AST-14 9321-F-27273 D5 3-AST-140 Aux Steam thru AST-15 9321-F-27273 D4 3-AST-141 Aux Steam thru AST-16 9321-F-27273 D4 3-AST-142 Aux Steam thru AST-17 9321-F-27273 D3 3-BD-048 Blowdown Tank vent to Atmosphere 9321-F-27293 F1 3-BD-055 SG Blowdown from Orifice upstream of Heat Exchanger #4 (A and B) 9321-F-24063 H6 3-BD-070 SG Blowdown to SGBDIX-1 9321-F-24063 E4 3-BD-085 SG Blowdown to SGBDIX-2 downstream of SGBDIX-1 drain 9321-F-24063 D5 3-BD-086 SG Blowdown to SGBDIX-3 downstream of SGBDIX-1 and SGBDIX-2 drain 9321-F-24063 C5 3-CD-007 Condensate to Steam Generator Blowdown HE #3 9321-F-20183 Sheet 2 D2 3-CD-032 Condensate from Header to BFP No. 31 9321-F-20183 Sheet 2 B4 3-CD-033 Condensate from Header to BFP No. 32 9321-F-20183 Sheet 2 B4 3-HD-001

  1. 31 HDP to Heater Drain Pump Header 9321-F-20223 Sheet 1 C4

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Revision 2 Page 17 of 19 Line Number Line Description P&ID Coord.

3-HD-002

  1. 32 HDP to Heater Drain Pump Header 9321-F-20223 Sheet 1 C5 3-MS-149 Main Steam Stop Valve drain to 33 Cond.

9321-F-20173 A5 3-MS-150 Main Steam Stop Valve drain to 33 Cond.

9321-F-20173 B5 3-MS-151 Header to 33 Cond.

9321-F-20173 A4 3-MSD-013 Reheater Drain Tank 31A Drain to Header 9321-F-20233 Sheet 1 C3 3-MSD-014 Reheater Drain Tank 32A Drain to Header 9321-F-20233 Sheet 1 C6 3-MSD-015 Reheater Drain Tank 33A Drain to Header 9321-F-20233 Sheet 1 D6 3-MSD-022 Reheater Drain Tank 31B Drain to Header 9321-F-20233 Sheet 2 F2 3-MSD-023 Reheater Drain Tank 32B Drain to Header 9321-F-20233 Sheet 2 D3 3-MSD-024 Reheater Drain Tank 33B Drain to Header 9321-F-20233 Sheet 2 D2 3-MSD-088 MS Drain Tank 31B Drain to Heater Drain Tank 9321-F-20233 Sheet 2 E8 3-MSD-089 MS Drain Tank 32B Drain to Heater Drain Tank 9321-F-20233 Sheet 2 E8 3-MSD-090 MS Drain Tank 33B Drain to Heater Drain Tank 9321-F-20233 Sheet 2 E8 3-PD-032 Moisture Preseparator 1B to Separation Chamber header 9321-F-20223 Sheet 1 H4 3-PD-033 Moisture Preseparator 1A to Separation Chamber header 9321-F-20223 Sheet 1 H4 3-PD-034 Moisture Preseparator 2B to Separation Chamber header 9321-F-20223 Sheet 1 H5 3-PD-035 Moisture Preseparator 2A to Separation Chamber header 9321-F-20223 Sheet 1 H6 3-SBF-006 Service Boiler Feed Pump 31 Low Flow Recirc line 9321-F-41293 F4 3-SBF-007 Service Boiler Feed Pump 32 Low Flow Recirc line 9321-F-41293 F3 3-UH-001 Aux Steam to Air Purge Heating Coils 9321-F-40573 E6 3-UH-220 Condensate Transfer Pump 31 Low Flow Recirc line 9321-F-41293 B2 3-UH-221 Condensate Transfer Pump 32 Low Flow Recirc line 9321-F-41293 C3 3-UHT-018 Aux Steam from RS-UH-1 thru steam trap UH-T-397 to Cond Receiver header 9321-F-41443 G6 3-UHT-019 Aux Steam from RS-HC-2 thru steam trap UH-T-409-2 to Cond Receiver header 9321-F-41443 G8 3-UHT-020 Aux Steam from RS-HC-4 thru steam trap UH-T-409-4 to Cond Receiver header 9321-F-41443 F8 3-UHT-021-A Aux Steam from RS-HC-3 thru steam trap UH-T-409-3 to Cond Receiver header 9321-F-41443 D8 3-UHT-022-A Aux Steam from RS-HC-1 thru steam trap UH-T-409-1 to Cond Receiver header 9321-F-41443 C8 3-UHT-023-A Aux Steam from RS-HX-1 thru steam trap UH-T-408-3 to Cond Receiver header 9321-F-41443 B8 3-UHT-228 Main Steam leak thru Steam Trap UH-T-11 to House Service Boiler Condensate Return Tank 9321-F-41283 B4

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Revision 2 Page 18 of 19

7.

References 7.1.

Erosion/Corrosion-Induced Pipe Wall Thinning, Generic Letter 89-08, U.S.

Nuclear Regulatory Commission (NRC), May 2, 1989.

7.2.

Recommendations for an Effective Flow-Accelerated Corrosion Program, EPRI NSAC 202L-R3, 1011838, May 2006.

7.3.

Indian Point Piping and Instrumentation Diagrams.

System (Drawing Title)

P&ID #

Rev #

Flow Diagram Symbols 9321-D-20163 6

Main Steam System 9321-F-20173 70 Condensate and Boiler Feed Pump System 9321-F-20183 Sheet 1 60 Condensate and Boiler Feed Pump System 9321-F-20183 Sheet 2 25 Boiler Feedwater System 9321-F-20193 57 Extraction Steam System 9321-F-20203 Sheet 1 7

Extraction Steam System 9321-F-20203 Sheet 2 27 Heater Vents and Drains 9321-F-20223 Sheet 1 34 Heater Vents and Drains 9321-F-20223 Sheet 2 9

Moisture Separator/Reheater Vents and Drains 9321-F-20233 Sheet 1 25 Moisture Separator/Reheater Vents and Drains 9321-F-20233 Sheet 2 13 Boiler Feed Pump Vents and Drains 9321-F-20243 15 Extraction Steam Traps 9321-F-20313 19 Main Steam Traps 9321-F-20413 25 Main Steam Traps 9321-F-20423 12 Steam Generator Blowdown Recovery System 9321-F-24063 11 Auxiliary Steam System 9321-F-27273 28 Steam Generator Blowdown 9321-F-27293 32 Auxiliary Steam Supply System 9321-F-40573 27 Auxiliary Steam Supply System 9321-F-41283 13 Auxiliary Steam Supply System 9321-F-41293 11 Auxiliary Steam System 9321-F-41443 5

Auxiliary Steam System 9321-F-41553 3

Auxiliary Steam System 9321-F-41563 3

Auxiliary Boiler/Reboiler Steam System 9321-F-41573 4

Gland Steam System B237144-4 Gland Steam System 9321-05-FP-2355

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Revision 2 Page 19 of 19 7.4.

Indian Point System Descriptions.

System Name SD No.

Steam Generators 1.2 Main and Reheat Steam 18.0 High Pressure and Low Pressure Steam Dumps 18.1 Extraction Steam Vents and Drains 19.0 Condensate 20.0 Main Feedwater 21.0 Steam Generator Water Level Control 21.1 Main Turbine & Generator Support Systems 26.1 Auxiliary Steam System 29.1 House Service Boiler 29.11 7.5.

Electronic correspondence between CSI and Indian Point personnel (see Attachment B).

7.5.1. Email from Chris Pott (CSI) to Ian Mew(IPEC) regarding information requests, dated 10/2/2009.

7.5.2. Conversation between Ian Mew (IPEC) and Chris Pott (CSI) regarding responses to information requests, dated 11/5/2009.

7.5.3. Conversation between Ian Mew (IPEC) and Chris Pott (CSI) regarding a missing P&ID, dated 11/17/2009.

7.6.

EPRI, Flow-Accelerated Corrosion in Power Plants, B. Chexal et al, EPRI TR-106611-R1, 1998.

7.7.

Indian Point Unit 3 Nuclear Power Plant, Specification for Pipe, Tube, Fittings,

& Fabrication of Piping and Tubing Assemblies. Specification No. TS-MS-024, Rev 2.

7.8.

Indian Point Isometric Drawings for FAC-susceptible piping, received by CSI on 4/3/2009.

7.9.

Indian Point New HPT, Tuned to TR-05097, 0.1% Moist High Pressure Turbine Expansion, Run Date 1/18/07.

7.10. CHECWORKS Steam/Feedwater Application Guidelines for Plant Modeling and Evaluation of Component Inspection Data. EPRI, Palo Alto, CA and CSI Technologies, Inc., Elgin, IL: 2009. 1019176 (For information only).

7.11. Indian Point FAC Program History Outage Reports, transmitted to CSI on 7/15/2009. (For information only).

7.12. Indian Point Unit 3 Nuclear Power Plant, Flow Accelerated Corrosion Susceptibility Review and Small-Bore & Augmented Monitoring Program.

Engineering Report No. IP3-RPT-MULT-03162, Rev 3 (For information only).

7.13. CHUG Industry Experience Documents (see Attachment A) (For information only).

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

System Susceptibility Evaluation Report Appendix A CSI TECHNOLOGIES, INC.

Report No. 0700.104-17, Appendix A, Revision 2 Page A-1 of 14

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

System Code System Name Susceptible?

Excl. Crit.

Comments Reference System Number CSI TECHNOLOGIES, INC.

Text19:

AS Auxiliary Steam Yes This system generates and distributes steam to the various auxiliaries requiring steam for operation.

Text19:

AST Auxiliary Steam Traps Yes This system consists of piping to and from steam traps associated with the Auxiliary Steam System P&ID Text19:

BD Steam Generator Blowdown Yes This system takes water from the steam generators for maintaining proper Steam Generator Chemistry. Also contains lines tagged as BDR.

P&ID Text19:

CD Condensate Pump Discharge Yes This system includes piping from some high temperature Feedwater Heaters.

TS-MS-024 Text19:

CT Condensate Storage & Transfer Yes Condensate transfer is used to ensure there is no raw water contamination of the condensate.

TS-MS-024 Addendum D Text19:

EST Extraction Steam Traps Yes This system consists of piping to and from steam traps associated with the Extraction Steam System P&ID Text19:

EX Extraction Steam Yes This system includes extraction steam to the Feedwater Heaters TS-MS-024 and Addendums Text19:

FW Main Feed Water Yes This system supplies feedwater to the steam generators.

TS-MS-024 Text19:

GS Gland Sealing Steam Yes This system supplies sealing steam to the HP, LP, and BFP Turbines.

P&ID Text19:

GST Gland Steam Traps Yes This system consists of piping to and from steam traps associated with the Gland Steam System P&ID Report No. 0700.104-17, Appendix A, Revision 2 Page A-2 of 14

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

System Code System Name Susceptible?

Excl. Crit.

Comments Reference System Number CSI TECHNOLOGIES, INC.

Text19:

HD Heater Drains & Vents Yes This system includes Feedwater Heater Drains and Vents, and piping from the Heater Drain Pumps to the Boiler Feed Pump suction.

P&ID Text19:

MS Main Steam Yes This system supplies steam to the HP and BFP Turbines and the MSRs.

TS-MS-024 Text19:

MSD Moisture Separator Reheater Drains Yes This system includes MSR Drains to the Heater Drain Tank, No. 35 Feedwater Heaters, and the Drains Collecting Tank P&ID Text19:

MST Main Steam Traps Yes This system consists of piping to and from steam traps associated with the Main Steam System P&ID Text19:

PD Moisture Preseparator Drains Yes This system removes moisture from piping upstream of the HP Turbine Crossunder Piping.

P&ID Text19:

RST Reheat Steam Traps Yes This system consists of piping to and from steam traps associated with the Reheat Steam System P&ID Text19:

SB Service Boiler Yes This system contains some steam piping from the Service Boiler.

TS-MS-024 Text19:

SBF Service Boiler Feed Pump Yes This system transfers water from the Deaerator to the Steam Drum TS-MS-024 Text19:

UH Condensate Return Unit Heaters to Service Boiler D Yes This system contains condensate from the condensate return unit heaters to the service boiler deaerator.

System Description 29.1 Text19:

UHT Condensate Return Unit Heater Steam Traps Yes This system includes all steam trap lines for the Condensate Return Unit Heaters to Service Boiler Deaerator system.

P&ID Text19:

VCD MSR Vent Chamber Discharge Yes This system contains steam from the MSRs.

TS-MS-024 Report No. 0700.104-17, Appendix A, Revision 2 Page A-3 of 14

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

System Code System Name Susceptible?

Excl. Crit.

Comments Reference System Number CSI TECHNOLOGIES, INC.

Text19:

A 4160 VAC No EP This is an electrical system that does not contain piping.

Text19:

AAC AAC EDG Controls & Excitation No EP This system does not contain piping.

Text19:

AAC Alternate AC Diesel Generator No EP This system contains only the generator and not the associated piping.

Text19:

AB Auxiliary Building No EP This system includes the building and not the associated piping.

Text19:

ABS Auxiliary Building Sump No ET This system handles low temperature water from floor drains.

Text19:

ABV Auxiliary Building Ventilations No EW This system vents non-condensable gases.

Text19:

AC Chill Water System No ET This system operates at under 200 degF Text19:

ACW Auxiliary Cooling Water No ET This system operates at under 200 degF Text19:

ADM Admin Building No EP This system includes the building and not the associated piping.

Text19:

ARMS Area Radiation Monitoring Systems No EP This system does not contain piping.

Text19:

B 480 VAC No EP This is an electrical system that does not contain piping.

Text19:

BA Breathing Air No EW This system does not contain water or steam.

Text19:

BMS Boron Management No EW This system does not contain water or steam.

Report No. 0700.104-17, Appendix A, Revision 2 Page A-4 of 14

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

System Code System Name Susceptible?

Excl. Crit.

Comments Reference System Number CSI TECHNOLOGIES, INC.

Text19:

BS Containment (Building) Spray No EI Containment spray only operates in emergency situations.

Text19:

CA Secondary Chemical Addition No EW This system does not contain water or steam.

Text19:

CCW Component Cooling Water System No ET This system provides low-temperature water to various equipment in the plant.

TS-MS-024 Addendum D Text19:

CEDM Control Element Drive Mechanism Control No EP This system does not contain piping.

Text19:

CF Chemical Feed No EW This system does not contain water or steam.

P&ID Text19:

CL Chlorination No EW This system does not contain water or steam.

P&ID Text19:

COMM Communications No EP This system does not contain piping.

Text19:

CP Cathodic Protection No EP This is an electrical system that does not contain piping.

Text19:

CPC Core Protection Calculators No EP This system does not contain piping.

Text19:

CPV Penetration Room Ventilation No EW This system vents non-condensable gases.

Text19:

CRDX Cardox (CO2 Fire Protection System)

No EW This system does not contain water or steam.

P&ID Text19:

CRV Control Room Ventilation No EW This system vents non-condensable gases.

Text19:

CS Condensate Pump Suction No ET This system transports low-temperature water from the Condensers to the Condensate Pump.

TS-MS-024 Text19:

CV Condenser Air Vents No EW This system does not contain water or steam.

TS-MS-024 Addendum D Report No. 0700.104-17, Appendix A, Revision 2 Page A-5 of 14

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

System Code System Name Susceptible?

Excl. Crit.

Comments Reference System Number CSI TECHNOLOGIES, INC.

Text19:

CVCS Chemical and Volume Control System No EM This system is comprised entirely of FAC-resistant piping.

TS-MS-024 Text19:

CVH Containment Vent Header No EW This system vents non-condensable gases.

Text19:

CW Circulating Water No EO This system provides river water to cool the steam in the condensers and temperature is below 200 degF.

TS-MS-024 Addendum D Text19:

D 125 VDC No EP This is an electrical system that does not contain piping.

Text19:

DA Diesel Generator Starting Air No EW This system does not contain water or steam.

TS-MS-024 Addendum D Text19:

DCH Drain Collection Header No EF Flow in this system is too low to facilitate FAC.

Text19:

DF Diesel Generator Fuel Oil No EW This system does not contain water or steam and temperature is below 200 degF.

TS-MS-024 Addendum D Text19:

DFAS Diverse Emergency Feed Actuation No EP This system does not contain piping.

Text19:

DSS Diverse Scram System No EP This system does not contain piping.

Text19:

DW Domestic Water No EO This system contains highly oxygenated water from the city supply.

Text19:

EC Plant Computer No EP This system does not contain piping.

Text19:

EDG Emergency Diesel Generator No EP This system does not contain piping.

Text19:

EDG EDG Controls & Excitation No EP This system does not contain piping.

Report No. 0700.104-17, Appendix A, Revision 2 Page A-6 of 14

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

System Code System Name Susceptible?

Excl. Crit.

Comments Reference System Number CSI TECHNOLOGIES, INC.

Text19:

EFW Emergency Feed Water No EI This system only operates in emergency situations.

Text19:

EHC Electro-Hydraulic (Mechanical)

No EP This system does not contain piping.

Text19:

EHC MFP EHC Controls No EP This system does not contain piping.

Text19:

EHC MTG EHC Controls No EP This system does not contain piping.

Text19:

EL Emergency Lighting (Safe Shutdown)

No EP This system does not contain piping.

Text19:

EOF Emergency Operations Facility No EP This system does not contain piping.

Text19:

ES ESFAS No EP This system does not contain piping.

Text19:

EXCT Main Generator Excitation &

Protection No EP This system does not contain piping.

Text19:

F Switchyard No EP This system does not contain piping.

Text19:

FD Fire Detection No EP This system does not contain piping.

Text19:

FHS Fuel Handling System No EW This system does not contain water or steam.

Text19:

FO Diesel Fuel Oil Storage and Transfer No EW This system does not contain water or steam.

P&ID Text19:

FP Spent Fuel Pool Cooling No ET This system operates at under 200 degF Text19:

FS Fire Protection (Water)

No ET This system uses low-temperature city water with high concentration of O2 P&ID Report No. 0700.104-17, Appendix A, Revision 2 Page A-7 of 14

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

System Code System Name Susceptible?

Excl. Crit.

Comments Reference System Number CSI TECHNOLOGIES, INC.

Text19:

FWCS Feed Water Control System No EF This system contains low-flow instrumentation lines.

Text19:

GCH Gas Collection Header No EW This system does not contain water or steam.

Text19:

GG Generator Gas No EW This system does not contain water or steam.

Text19:

GSO Hydrogen Seal Oil (Mechanical)

No EW This system does not contain water or steam.

Text19:

GZ Gaseous Radwaste No EW This system does not contain water or steam.

Text19:

H 6900 VAC No EP This is an electrical system that does not contain piping.

Text19:

H2 Hydrogen No EW This system does not contain water or steam.

Text19:

HAL Halon No EW This system does not contain water or steam.

Text19:

HPA Hydrogen Purge System No EW This system does not contain water or steam.

Text19:

HPSI High Pressure Safety Injection No EM Lines in this system are composed of FAC-resistant material.

Pipe Spec Text19:

HR H2 Recombiners No EW This system does not contain water or steam.

Text19:

HS Generator Hydrogen Supply No EW This system provides hydrogen to the steam generators.

P&ID Text19:

HT Heat Tracking No EP This system does not contain piping.

Text19:

IA Instrument Air No EW This system does not contain water or steam.

TS-MS-024 Addendum F1 Report No. 0700.104-17, Appendix A, Revision 2 Page A-8 of 14

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

System Code System Name Susceptible?

Excl. Crit.

Comments Reference System Number CSI TECHNOLOGIES, INC.

Text19:

IB Isophase Bus No EP This system does not contain piping.

Text19:

IBC Isophase Bus Cooling No ET This system operates at under 200 degF Text19:

IC Incore Instrumentation No EF This system contains low-flow instrumentation lines.

Text19:

ICC Reactor Vessel Level Monitoring &

CETs No EF This system contains low-flow instrumentation lines.

Text19:

IS Intake Structure No EO This system contains highly oxygenated water.

Text19:

JW Diesel Generator Jacket Water No EO This system is fed with raw water with high O2 content and does not exceed 200 degF.

TS-MS-024 Addendum D Text19:

K Annunciators No EP This system does not contain piping.

Text19:

LA 120/208 VAC Misc. Lighting &

Power Dist.

No EP This is an electrical system that does not contain piping.

Text19:

LLRW Low Level Radwaste Bldg No EP This system does not contain piping.

Text19:

LO Main Turbine Lube Oil No EW This system does not contain water or steam.

P&ID Text19:

LPSI Low Pressure Safety Injection No EM Lines in this system are composed of FAC-resistant material.

Pipe Spec Text19:

LRBV Low Level Radwaste Building Ventilation No EW This system vents non-condensable gases.

Text19:

LRW Liq Radwaste Mgmt No EW This system does not contain water or steam.

Text19:

MET Meteorological Instrumentation No EP This system does not contain piping.

Report No. 0700.104-17, Appendix A, Revision 2 Page A-9 of 14

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

System Code System Name Susceptible?

Excl. Crit.

Comments Reference System Number CSI TECHNOLOGIES, INC.

Text19:

MW City Water Make-Up No EO This system contains highly oxygenated water from the city supply and temperature does not exceed 200 degF.

TS-MS-024 Text19:

N2 Nitrogen No EW This system does not contain water or steam.

P&ID Text19:

NI Nuclear Instrumentation No EP This system does not contain piping.

Text19:

NT Neutralizing System No EP This system does not contain piping.

Text19:

PA Reactor Building Purge Air No EW This system does not contain water or steam.

Text19:

PASS Post Accident Sampling No EI This system only operates in post-accident conditions Text19:

PCA Penetration Cooling Air No EW This system does not contain water or steam and temperature is below 200 degF.

TS-MS-024 Addendum D Text19:

PH Plant Heating No EW This system does not contain water or steam.

Text19:

PMU Makeup Demineralizer System No ET This system operates at under 200 degF Text19:

PPS Plant Protection System No EP This system does not contain piping.

Text19:

PS Primary Sampling No EI This system operates less than 2% of plant operation Text19:

PW Primary Water No ET This system contains low-temperature water and is comprised of FAC-resistant material.

TS-MS-024 Text19:

RB Reactor Building No EP This system does not contain piping.

Report No. 0700.104-17, Appendix A, Revision 2 Page A-10 of 14

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

System Code System Name Susceptible?

Excl. Crit.

Comments Reference System Number CSI TECHNOLOGIES, INC.

Text19:

RBHV Reactor Building Ventilation No EW This system vents non-condensable gases.

Text19:

RCP Reactor Coolant Pumps No EP This system does not contain piping.

Text19:

RCS Reactor Coolant System No EM This system is comprised entirely of FAC-resistant piping.

TS-MS-024 Text19:

RDAC/S PING RDAC (Radiation Dose Assessment Computer)/SPING (S No EP This system does not contain piping.

Text19:

RHR Residual Heat Removal System No EM All lines in the RHR system are stainless steel.

Text19:

RMS Radiation Monitoring No EP This system does not contain piping.

Text19:

RPS Reactor Protection System No EP This system does not contain piping.

Text19:

RRS Reactor Regulating System No EP This system does not contain piping.

Text19:

RS Reheat Steam No EQ Reheater Steam provides superheated steam to the LP and BFP Turbines.

TS-MS-024 Text19:

RT Resin Transfer No EW This system does not contain water or steam.

Text19:

RWB Radwaste Building No EP This system does not contain piping.

Text19:

RX Reactor Core No EP This system does not contain piping.

Text19:

RZ Regen Waste No EP This system does not contain piping.

Text19:

SA Service Air No EW This system does not contain water or steam and temperature is below 200 degF.

TS-MS-024 Report No. 0700.104-17, Appendix A, Revision 2 Page A-11 of 14

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

System Code System Name Susceptible?

Excl. Crit.

Comments Reference System Number CSI TECHNOLOGIES, INC.

Text19:

SDBC Steam Dump Bypass Control System No EP This system does not contain piping.

Text19:

SDC Shutdown Cooling No EI This system only operates during shutdown.

Text19:

SEC Security No EP This system does not contain piping.

Text19:

SFP Spent Fuel Pit No ET The water in this system is low-temperature.

Text19:

SGS Stm. Gen. Secondary No EP This system does not contain piping.

Text19:

SI Safety Injection System No EM This system is comprised entirely of FAC-resistant piping.

TS-MS-024 Text19:

SMS Seismic Monitoring System No EP This system does not contain piping.

Text19:

SP Sample System No EM Sample piping at IPEC is stainless steel.

TS-MS-024 Text19:

SPDS Safety Parameter Display System No EP This system does not contain piping.

Text19:

SS Secondary Sampling No EM Sample piping at IPEC is stainless steel.

Pipe Spec Text19:

STP Sewage Treatment Plant No EP This system does not contain piping.

Text19:

SW Service Water No EO Service Water has a high concentration of dissolved oxygen.

P&ID Text19:

SWC Stator Water Cooling No ET This system operates at under 200 degF Text19:

SZ Solid Waste Management No EW This system does not contain water or steam.

Report No. 0700.104-17, Appendix A, Revision 2 Page A-12 of 14

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

System Code System Name Susceptible?

Excl. Crit.

Comments Reference System Number CSI TECHNOLOGIES, INC.

Text19:

TB Turbine Building No EP This system does not contain piping.

Text19:

TBS Turbine Building Sump No EF Flow in this system is too low to facilitate FAC.

Text19:

TBV Turbine Building Ventilation No EW This system vents non-condensable gases.

Text19:

TG Main Turbine & Generator No EP This system does not contain piping.

Text19:

TG MTG & MFPT Supervisory Instrumentation No EP This system does not contain piping.

Text19:

TS Traveling Screens No EP This system does not contain piping.

Text19:

VENT Miscellaneous Ventilation System No EW This system vents non-condensable gases.

Text19:

VLPM U3 Vibration & Loose Parts Monitoring System No EP This system does not contain piping.

Text19:

VS Condenser Vacuum No EW This system vents non-condensable gases.

Text19:

WCP Weld Channel Pressurization No EW This system does not contain water or steam.

P&ID Text19:

XFMR Main, Auxiliary & Startup Transformers No EP This system does not contain piping.

Text19:

Y Inverters & Vital 120 VAC No EP This is an electrical system that does not contain piping.

Report No. 0700.104-17, Appendix A, Revision 2 Page A-13 of 14

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

System Code System Name Susceptible?

Excl. Crit.

Comments Reference System Number CSI TECHNOLOGIES, INC.

Exclusion Criteria Legend:

EC EF EI EM EO EP EQ ER ET EW Excluded due to Combination of infrequent op above temp threshold Excluded due to low or no Flow Excluded due to Infrequent operation Excluded due to FAC-resistant Material Excluded due to high dissolved Oxygen content Exluded, does not contain Piping Excluded due to high steam Quality Excluded, Removed from service and "cut" and "capped" Excluded due to operating Temperature (single phase, < 200 deg F)

Excluded because system, subsytem, or line is non-Water Report No. 0700.104-17, Appendix A, Revision 2 Page A-14 of 14

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Subsystem Susceptibility Evaluation Report Appendix B CSI TECHNOLOGIES, INC.

Indian Point Unit 3 Report No. 0700.104-17, Appendix B, Revision 2 Page B-1 of 25

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Auxiliary Steam (AS), Unit 3 Subsystem Number Subsystem Name FAC Sus?

Excl.

Crit.

Comments Reference Subsystem Boundary P&ID No.

Text19:

3-AS-01 Auxiliary Steam to RS-HC-1 thru 4, RS-UH-1, and RS-HX-1 Yes P&ID 9321-F-41443, 9321-F-27273 Report No. 0700.104-17, Appendix B, Revision 2 Page B-2 of 25

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Auxiliary Steam Traps (AST), Unit 3 Subsystem Number Subsystem Name FAC Sus?

Excl.

Crit.

Comments Reference Subsystem Boundary P&ID No.

Text19:

3-AST-01 Auxiliary Steam Trap lines Yes P&ID 9321-F-4573 Report No. 0700.104-17, Appendix B, Revision 2 Page B-3 of 25

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Steam Generator Blowdown (BD), Unit 3 Subsystem Number Subsystem Name FAC Sus?

Excl.

Crit.

Comments Reference Subsystem Boundary P&ID No.

Text19:

3-BD-01 Steam Generator Blowdown to Blowdown Tank and Sample Cooler Yes P&ID 9321-F-27293 Sheet 1, 9321-F-24063, 9321-F-20183 Sheet 1

Text19:

3-BD-02 Steam Generator Blowdown from Sample Cooler to Steam Generator Blowdown Flash Tank No 31 No EM Sample lines are all SS TS-MS-024 9321-F-27293 Sheet 1 Report No. 0700.104-17, Appendix B, Revision 2 Page B-4 of 25

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Pump Discharge (CD), Unit 3 Subsystem Number Subsystem Name FAC Sus?

Excl.

Crit.

Comments Reference Subsystem Boundary P&ID No.

Text19:

3-CD-01 Condensate Lines Between Condensate Pumps and #32 Feedwater Heaters No ET Condensate is below 200 degF before passing through the #32 FWHs PEPSE 9321-F-20183 Text19:

3-CD-02 Condensate Lines Downstream of #32 Feedwater Heaters Yes PEPSE 9321-F-20183 Sheet 1 and 2, 9321-F-20193 Report No. 0700.104-17, Appendix B, Revision 2 Page B-5 of 25

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Storage & Transfer (CT), Unit 3 Subsystem Number Subsystem Name FAC Sus?

Excl.

Crit.

Comments Reference Subsystem Boundary P&ID No.

Text19:

3-CT-01 Lines from the Boiler Feed Pump Turbine Drip Tank to the Drip Tank Drain Pumps Yes Pipe Spec 9321-F-20243 Text19:

3-CT-02 All other Condensate Transfer lines No ET This system operates at below 200 degF TS-MS-024 Addendum D Multiple P&IDs Report No. 0700.104-17, Appendix B, Revision 2 Page B-6 of 25

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Extraction Steam Traps (EST), Unit 3 Subsystem Number Subsystem Name FAC Sus?

Excl.

Crit.

Comments Reference Subsystem Boundary P&ID No.

Text19:

3-3EST-01 LP Turbine Extraction Steam to #33 FWHs Steam Traps Yes P&ID 9321-F-20313 Text19:

3-4EST-01 Extraction Steam Lines upstream of Steam Traps No EQ Steam is superheated upstream of the steam traps.

P&IDs 9321-F-20313 Text19:

3-4EST-02 Steam Traps to the Steam Trap Drains Header from Extraction lines to #34 FWHs Yes PEPSE 9321-F-20313 Text19:

3-5EST-01 Extraction Steam to

  1. 35 FWHs Steam Traps Yes P&ID 9321-F-20203 Sheet 1, 9321-F-20313 Text19:

3-6EST-01 HP Turbine Extraction Steam to Extraction Steam Traps Yes P&ID 9321-F-20313 Text19:

3-6EST-02 Extraction Steam Trap Drain Headers to the Drains Collecting Tank Yes P&ID 9321-F-20313 Report No. 0700.104-17, Appendix B, Revision 2 Page B-7 of 25

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Extraction Steam (EX), Unit 3 Subsystem Number Subsystem Name FAC Sus?

Excl.

Crit.

Comments Reference Subsystem Boundary P&ID No.

Text19:

3-1EX-01 LP Turbine Extraction Steam to #31 Feedwater Heaters Yes PEPSE 9321-F-20203 Text19:

3-2EX-01 LP Turbine Extraction Steam to #32 Feedwater Heaters Yes PEPSE 9321-F-20203 Text19:

3-3EX-01 LP Turbine Extraction Steam to #33 Feedwater Heaters Yes PEPSE 9321-F-20203, 9321-F-20313 Text19:

3-3EX-02 Boiler Feed Pump Turbine Drains to Condensers Yes PEPSE 9321-F-20173, 9321-F-20243 Text19:

3-4EX-01 Extraction Steam Lines to #34 Feedwater Heaters No EQ Steam is superheated.

P&IDs 9321-F-20203, 9321-F-20313 Text19:

3-5EX-01 HP Turbine Crossunder Piping Leakoff Drains to Condensers Yes PEPSE 9321-F-20203 Text19:

3-5EX-02 Extraction Steam from Moisture Preseparators to #35 Feedwater Heaters Yes PEPSE 9321-F-20203, 9321-F-20313 Text19:

3-5EX-03 Small Bore Steam Drains to the Condenser via FCV-1156, 1164, 1165, and 1166.

No EI Control valves in these lines are normally closed.

P&IDs 9321-F-20203 Report No. 0700.104-17, Appendix B, Revision 2 Page B-8 of 25

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Extraction Steam (EX), Unit 3 Subsystem Number Subsystem Name FAC Sus?

Excl.

Crit.

Comments Reference Subsystem Boundary P&ID No.

Text19:

3-6EX-01 HP Turbine Extraction Steam to #36 Feedwater Heaters Yes PEPSE 9321-F-20203, 9321-F-20313 Report No. 0700.104-17, Appendix B, Revision 2 Page B-9 of 25

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Feed Water (FW), Unit 3 Subsystem Number Subsystem Name FAC Sus?

Excl.

Crit.

Comments Reference Subsystem Boundary P&ID No.

Text19:

3-FW-01 Feedwater Lines from the Boiler Feed Pumps to the Steam Generators Yes PEPSE 9321-F-20193 Text19:

3-FW-02 Auxiliary Feedwater Lines to Steam Generator No EI Auxiliary Feedwater only operates during startup, shutdown, and emergency conditions.

TS-MS-024 9321-F-20193 Text19:

3-FW-03 Boiler Feed Pump Recirc Lines to the Drains Collecting Tank No EM All lines in this subsystem have been replaced with CrMo.

SFA Model 9321-F-20193 Report No. 0700.104-17, Appendix B, Revision 2 Page B-10 of 25

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Gland Sealing Steam (GS), Unit 3 Subsystem Number Subsystem Name FAC Sus?

Excl.

Crit.

Comments Reference Subsystem Boundary P&ID No.

Text19:

3-GS-01 Gland Steam to and from HP, LP, and BFP Turbines Yes PEPSE 9321-F-20243, 9321-F-20313, 9321-05-FP-2355, B237144 Report No. 0700.104-17, Appendix B, Revision 2 Page B-11 of 25

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Gland Steam Traps (GST), Unit 3 Subsystem Number Subsystem Name FAC Sus?

Excl.

Crit.

Comments Reference Subsystem Boundary P&ID No.

Text19:

3-GST-01 Gland Steam to and from Steam Traps Yes PEPSE 9321-F-20243 Report No. 0700.104-17, Appendix B, Revision 2 Page B-12 of 25

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Heater Drains & Vents (HD), Unit 3 Subsystem Number Subsystem Name FAC Sus?

Excl.

Crit.

Comments Reference Subsystem Boundary P&ID No.

Text19:

3-1HD-01

  1. 31 Feedwater Heater Drain Lines Yes PEPSE 9321-F-20223 Sheet 2 Text19:

3-1HD-02

  1. 31 Feedwater Heater Vents Yes P&ID 9321-F-20223 Sheet 2 Text19:

3-2HD-01

  1. 32 Feedwater Heater Drain Lines Yes PEPSE 9321-F-20223 Sheet 2 Text19:

3-2HD-02

  1. 32 Feedwater Heater Vents Yes P&ID 9321-F-20223 Sheet 2 Text19:

3-3HD-01

  1. 33 Feedwater Heater Drain Lines Yes PEPSE 9321-F-20223 Sheet 2 Text19:

3-3HD-02

  1. 33 Feedwater Heater Vents No EM All lines in this subsystem have been replaced with CrMo.

IP3-RPT-MULT-03162, Rev.

3, Appendix B 9321-F-20223 Sheet 2 Text19:

3-4HD-01

  1. 34 Feedwater Heater Drain Lines Yes PEPSE 9321-F-20223 Sheet 2 Text19:

3-4HD-02

  1. 34 Feedwater Heater Vents Yes P&ID 9321-F-20223 Sheet 2 Text19:

3-5HD-01 Heater Drains from

  1. 35 Feedwater Heaters Yes PEPSE 9321-F-20223 Sheet 1 Text19:

3-5HD-02 Heater Vents from

  1. 35 Feedwater Heater and Heater Drain Tank vents to #35 Feedwater Heaters and Flas Yes PEPSE 9321-F-20223 Sheet 1 and 2 Report No. 0700.104-17, Appendix B, Revision 2 Page B-13 of 25

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Heater Drains & Vents (HD), Unit 3 Subsystem Number Subsystem Name FAC Sus?

Excl.

Crit.

Comments Reference Subsystem Boundary P&ID No.

Text19:

3-5HD-03 HDT Drains to Heater Drain Pumps and Condensers and Heater Drain Pump Vents to HDT Yes PEPSE 9321-F-20223 Sheet 1 and 2 Text19:

3-6HD-01 Heater Drains from

  1. 36 Feedwater Heaters Yes PEPSE 9321-F-20223 Sheet 1 and 2 Text19:

3-6HD-02 Heater Vents from

  1. 36 Feedwater Heater Yes PEPSE 9321-F-20223 Sheet 1, 9321-F-20313 Text19:

3-HD-01 Heater Drain Pump discharge to Boiler Feed Pumps Yes PEPSE 9321-F-20223, 9321-F-20183 Sheet 2 Report No. 0700.104-17, Appendix B, Revision 2 Page B-14 of 25

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Steam (MS), Unit 3 Subsystem Number Subsystem Name FAC Sus?

Excl.

Crit.

Comments Reference Subsystem Boundary P&ID No.

Text19:

3-MS-01 Main Steam from SG to HP Turbine, BFP Turbine, MSRs, Aux.

Steam, SJAEs, and Priming Ejectors.

Yes PEPSE 9321-F-20173, 9321-F-20233 Sheet 1 and 2, 9321-F-20413, 9321-F-20423, 9321-F-41573, 9321-F-41283 Text19:

3-MS-02 Main Steam to MSR Header Dumps to Condenser No EI Infrequent use - normally closed valve shown on P&ID P&ID 9321-F-20173 Text19:

3-MS-03 Main Steam to Auxiliary FW Turbine No EI Infrequent use - normally closed valve shown on P&ID P&ID 9321-F-20173 Text19:

3-MS-04 Turbine Steam Drains via PCV-1134, 1135, 1136, and 1137 No EI Control valves in these lines are normally closed.

P&ID 9321-F-20173 Text19:

3-MS-05 Drains from Main Steam to Swap Lab No EI Control valves in these lines are normally closed.

P&ID 9321-F-20173 Text19:

3-MS-06 Small Bore Turbine Steam Drains to the Condenser via FCV-1154, 1155, 1157, 1158, and 1159 No EI Control valves in these lines are normally closed.

IP3-RPT-Mult-03162 9321-F-20173 Text19:

3-MS-07 H.P. Cylinder Steam Heating and Seals No EI Control valves in line are closed during normal operation.

SD No. 18.0 9321-F-20173 Text19:

3-MS-08 Main Steam Supply to Gland Steam Header Yes P&ID 9321-F-20173, 9321-F-20313, 9321-F-20243 Text19:

3-MS-09 H.P. Turbine Control Valve Piping Yes P&ID 9321-05-FP-2355 Report No. 0700.104-17, Appendix B, Revision 2 Page B-15 of 25

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Steam (MS), Unit 3 Subsystem Number Subsystem Name FAC Sus?

Excl.

Crit.

Comments Reference Subsystem Boundary P&ID No.

Text19:

3-MS-10 HP Turbine Crossunder Piping to MSRs and condensers Yes PEPSE 9321-F-20203 Text19:

3-MS-11 Scavenging Steam from 6th Stage Extraction Steam No ER Source line shown capped on P&ID P&ID 9321-F-20233 Sheet 1 and 2 Report No. 0700.104-17, Appendix B, Revision 2 Page B-16 of 25

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Moisture Separator Reheater Drains (MSD), Unit 3 Subsystem Number Subsystem Name FAC Sus?

Excl.

Crit.

Comments Reference Subsystem Boundary P&ID No.

Text19:

3-MSD-01 Moisture Separator Drains to the Heater Drain Tank Yes PEPSE 9321-F-20233 Sheet 1 and 2 Text19:

3-MSD-02 Reheater Drains to

  1. 36 Feedwater Heaters Yes PEPSE 9321-F-20233 Sheet 1 and 2 Report No. 0700.104-17, Appendix B, Revision 2 Page B-17 of 25

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Steam Traps (MST), Unit 3 Subsystem Number Subsystem Name FAC Sus?

Excl.

Crit.

Comments Reference Subsystem Boundary P&ID No.

Text19:

3-MST-01 Main Steam lines surrounding Main Steam Traps Yes P&ID 9321-F-41573 Report No. 0700.104-17, Appendix B, Revision 2 Page B-18 of 25

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Moisture Preseparator Drains (PD), Unit 3 Subsystem Number Subsystem Name FAC Sus?

Excl.

Crit.

Comments Reference Subsystem Boundary P&ID No.

Text19:

3-PD-01 Moisture Preseparator Lines Yes PEPSE 9321-F-20223 Sheet 1 Report No. 0700.104-17, Appendix B, Revision 2 Page B-19 of 25

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Reheat Steam Traps (RST), Unit 3 Subsystem Number Subsystem Name FAC Sus?

Excl.

Crit.

Comments Reference Subsystem Boundary P&ID No.

Text19:

3-RST-01 Reheat Steam lines upstream of Steam Traps No EQ Reheat Steam is superheated upstream of the Steam Traps PEPSE 9321-F-20243 Text19:

3-RST-02 Reheat Steam from Steam Traps to Boiler Feed Pump Turbine Drip Tank Yes PEPSE 9321-F-20243 Report No. 0700.104-17, Appendix B, Revision 2 Page B-20 of 25

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Service Boiler (SB), Unit 3 Subsystem Number Subsystem Name FAC Sus?

Excl.

Crit.

Comments Reference Subsystem Boundary P&ID No.

Text19:

3-SB-01 Auxiliary Steam lines to and from the Reboiler No ER The Reboiler has been removed from service SD No. 18.0, IP3-RPT-MULT-03162 9321-F-41573 Text19:

3-SB-02 Service Boiler Lines Yes P&IDs 9321-F-41573, 9321-F-40573, 9321-F-20173, 9321-F-41283, 9321-F-41293 Report No. 0700.104-17, Appendix B, Revision 2 Page B-21 of 25

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Service Boiler Feed Pump (SBF), Unit 3 Subsystem Number Subsystem Name FAC Sus?

Excl.

Crit.

Comments Reference Subsystem Boundary P&ID No.

Text19:

3-SBF-01 Service Boiler lines from Deaerator to Steam Drum thru Service Boiler Feed Pumps Yes P&ID 9321-F-41293, 9321-F-41283 Report No. 0700.104-17, Appendix B, Revision 2 Page B-22 of 25

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Return Unit Heaters to Service Boiler D (UH), Unit 3 Subsystem Number Subsystem Name FAC Sus?

Excl.

Crit.

Comments Reference Subsystem Boundary P&ID No.

Text19:

3-UH-01 Auxiliary Steam Lines to Various Equipment Yes P&IDs 9321-F-40573, 9321-F-27273, 9321-F-41443, 9321-F-41553, 9321-F-41293, 9321-F-41283 Text19:

3-UH-02 Aux Steam to Radiation Monitor No ET Sample is cooled and therefore excluded P&IDs 9321-F-27273, 9321-F-41443 Report No. 0700.104-17, Appendix B, Revision 2 Page B-23 of 25

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Return Unit Heater Steam Traps (UHT), Unit 3 Subsystem Number Subsystem Name FAC Sus?

Excl.

Crit.

Comments Reference Subsystem Boundary P&ID No.

Text19:

3-UHT-01 Auxiliary Steam to Steam Traps Yes P&ID 9321-F-41553 Report No. 0700.104-17, Appendix B, Revision 2 Page B-24 of 25

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

MSR Vent Chamber Discharge (VCD), Unit 3 Subsystem Number Subsystem Name FAC Sus?

Excl.

Crit.

Comments Reference Subsystem Boundary P&ID No.

Text19:

3-VCD-01 Moisture Separator Reheater Vent Chamber Discharge Lines Yes PEPSE 9321-F-20233 Sheet 1 and 2, 9321-F-20203 Exclusion Criteria (Excl. Crit.) Legend:

EC EF EI EM EO EP EQ ER ET EW Excluded due to Combination of infrequent op above temp threshold Excluded due to low or no Flow Excluded due to Infrequent operation Excluded due to FAC-resistant Material Excluded due to high dissolved Oxygen content Exluded, does not contain Piping Excluded due to high steam Quality Excluded, Removed from service and "cut" and "capped" Excluded due to operating Temperature (single phase, < 200 deg F)

Excluded because system, subsytem, or line is non-Water Report No. 0700.104-17, Appendix B, Revision 2 Page B-25 of 25

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Line Susceptibility Evaluation Report Appendix C CSI TECHNOLOGIES, INC.

Indian Point Unit 3 Report No. 0700.104-17, Appendix C, Revision 2 Page C-1 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Auxiliary Steam (AS), Unit 3 Section B: SNM Program Lines 3-AS-01: Auxiliary Steam to RS-HC-1 thru 4, RS-UH-1, and RS-HX-1 Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-AS-001 1.25 S

Aux Steam to RS-UH-1 Operating conditions unknown.

P&ID NC 9321-F-41443 Text19:

3-AS-002 1

S Aux Steam to PRV Station Operating conditions unknown.

P&ID NC 9321-F-41443 Text19:

3-AS-003 2.5 S

Aux Steam to RS-HC-2 Operating conditions unknown.

P&ID NC 9321-F-41443 Text19:

3-AS-004 3

S Aux Steam to RS-HC-4 Operating conditions unknown.

P&ID NC 9321-F-41443 Text19:

3-AS-005 2.5 S

Aux Steam to RS-HC-1 Operating conditions unknown.

P&ID NC 9321-F-41443 Text19:

3-AS-006 2

S Aux Steam to RS-HX-1 Operating conditions unknown.

P&ID NC 9321-F-41443 Text19:

3-AS-007 2.5 S

Aux Steam to RS-HC-3 Operating conditions unknown.

P&ID NC 9321-F-41443 Text19:

3-AS-024 2.5 S

Header to Cond Receiver Operating conditions unknown.

P&ID NC 9321-F-41443 Text19:

3-AS-049 1.5 S

Cond Receiver exit through RS Pump 3

Operating conditions unknown.

P&ID NC 9321-F-41443 Text19:

3-AS-050 1.5 S

Cond Receiver exit through RS Pump 4

Operating conditions unknown.

P&ID NC 9321-F-41443 Text19:

3-AS-051 1.5 S

Drain to Condensate Receiver IP3V-138-0001 Operating conditions unknown.

P&ID NC 9321-F-41443, 9321-F-27273 Section C: Excluded Lines 3-AS-01: Auxiliary Steam to RS-HC-1 thru 4, RS-UH-1, and RS-HX-1 Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-AS-026 0.75 E

Valve TCV 390-1 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41443 Text19:

3-AS-028 0.75 E

Valve TCV 390-3 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41443 Text19:

3-AS-031 0.75 E

Valve TCV 390-5 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41443 Report No. 0700.104-17, Appendix C, Revision 2 Page C-2 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Auxiliary Steam (AS), Unit 3 Section C: Excluded Lines 3-AS-01: Auxiliary Steam to RS-HC-1 thru 4, RS-UH-1, and RS-HX-1 Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-AS-033 0.75 E

Valve TCV 390-4 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41443 Text19:

3-AS-039 0.75 E

Valve TCV 390-2 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41443 Text19:

3-AS-041 0.75 E

Valve PCV 401 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41443 Text19:

3-AS-044 0.75 E

Valve TCV 453 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41443 Text19:

3-AS-048 1

E Vent to Atmosphere Low to no flow in vent to atmosphere P&ID EF 9321-F-41443 Report No. 0700.104-17, Appendix C, Revision 2 Page C-3 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Auxiliary Steam Traps (AST), Unit 3 Section B: SNM Program Lines 3-AST-01: Auxiliary Steam Trap lines Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-AST-002 1.5 S

Aux Steam to AST-30 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-AST-010 0.75 S

Aux Steam to AST-26 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-AST-011 0.75 S

Aux Steam to AST-3 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-AST-012 0.75 S

Aux Steam from AST-26 to Cond Receiver Header Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-AST-013 0.75 S

Aux Steam from AST-3 to Cond Receiver Header Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-AST-104 1

S Aux Steam to and from AST-10 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-AST-115 1.5 S

Aux Steam from Primary Water Storage Tank through AST-19 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-AST-122 1

S Aux Steam thru AST-12 to Cond Receiver Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-AST-133 1

S Aux Steam thru AST-21 to Cond Receiver Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-AST-134 1

S Aux Steam thru AST-20 to Cond Receiver Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-AST-137 1

S Aux Steam thru AST-27 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-AST-138 1

S Aux Steam thru AST-13 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-AST-139 0.75 S

Aux Steam thru AST-14 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-AST-140 0.75 S

Aux Steam thru AST-15 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-AST-141 0.75 S

Aux Steam thru AST-16 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-AST-142 0.75 S

Aux Steam thru AST-17 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-AST-174 1

S Aux Steam thru AST-28 Operating conditions unknown.

P&ID NC 9321-F-27273 Report No. 0700.104-17, Appendix C, Revision 2 Page C-4 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Auxiliary Steam Traps (AST), Unit 3 Section B: SNM Program Lines 3-AST-01: Auxiliary Steam Trap lines Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-AST-236 2

S Aux Steam to Primary Water Storage Tank Operating conditions unknown.

P&ID NC 9321-F-27273 Section C: Excluded Lines 3-AST-01: Auxiliary Steam Trap lines Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-AST-004 0.75 E

AST-30 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-40573 Text19:

3-AST-014 0.75 E

AST-26 bypass Valve shown closed on P&ID.

P&ID EI 9321-F-40573 Text19:

3-AST-015 0.75 E

AST-3 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-40573 Text19:

3-AST-105 1

E AST-10 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-27273 Text19:

3-AST-123 1

E AST-12 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-27273 Text19:

3-AST-135 1

E AST-21 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-27273 Text19:

3-AST-136 1

E AST-20 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-27273 Text19:

3-AST-143 1

E AST-13 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-27273 Text19:

3-AST-144 0.75 E

AST-14 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-27273 Text19:

3-AST-145 0.75 E

AST-15 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-27273 Text19:

3-AST-146 0.75 E

AST-16 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-27273 Text19:

3-AST-147 0.75 E

AST-17 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-27273 Report No. 0700.104-17, Appendix C, Revision 2 Page C-5 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Steam Generator Blowdown (BD), Unit 3 Section B: SNM Program Lines 3-BD-01: Steam Generator Blowdown to Blowdown Tank and Sample Cooler Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-BD-001 2.5 S

SG 31 Blowdown via BD-1-2 Operating conditions unknown.

P&ID NC 9321-F-27293 Text19:

3-BD-002 2.5 S

SG 31 Blowdown via BD-1-1 Operating conditions unknown.

P&ID NC 9321-F-27293 Text19:

3-BD-004 2

S SG 32 Blowdown via BD-1-4 Operating conditions unknown.

P&ID NC 9321-F-27293 Text19:

3-BD-006 2

S SG 32 Blowdown via BD-1-3 Operating conditions unknown.

P&ID NC 9321-F-27293 Text19:

3-BD-008 2

S SG 33 Blowdown via BD-1-6 Small bore piping with unknown conditions.

P&ID NS 9321-F-27293 Text19:

3-BD-010 2

S SG 33 Blowdown via BD-1-5 Small bore piping with unknown conditions.

P&ID NS 9321-F-27293 Text19:

3-BD-011 2.5 S

SG 34 Blowdown via BD-1-8 Operating conditions unknown.

P&ID NC 9321-F-27293 Text19:

3-BD-012 2.5 S

SG 34 Blowdown via BD-1-7 Operating conditions unknown.

P&ID NC 9321-F-27293 Text19:

3-BD-013 1

S SG 31 Shell Drain Operating conditions unknown.

P&ID NC 9321-F-27293 Text19:

3-BD-015 1

S SG 32 Shell Drain Operating conditions unknown.

P&ID NC 9321-F-27293 Text19:

3-BD-017 1

S SG 33 Shell Drain Operating conditions unknown.

P&ID NC 9321-F-27293 Text19:

3-BD-019 1

S SG 34 Shell Drain Operating conditions unknown.

P&ID NC 9321-F-27293 Text19:

3-BD-020 4

S SG 31 Blowdown Operating conditions unknown.

P&ID NC 9321-F-27293 Text19:

3-BD-021 4

S SG 32 Blowdown Operating conditions unknown.

P&ID NC 9321-F-27293 Text19:

3-BD-022 4

S SG 33 Blowdown Operating conditions unknown.

P&ID NC 9321-F-27293 Text19:

3-BD-023 4

S SG 34 Blowdown Operating conditions unknown.

P&ID NC 9321-F-27293 Text19:

3-BD-024 0.5 S

SG 31 Blowdown drain Operating conditions unknown.

P&ID NC 9321-F-27293 Text19:

3-BD-025 0.5 S

SG 32 Blowdown drain Operating conditions unknown.

P&ID NC 9321-F-27293 Text19:

3-BD-026 0.5 S

SG 33 Blowdown drain Operating conditions unknown.

P&ID NC 9321-F-27293 Text19:

3-BD-027 0.5 S

SG 34 Blowdown drain Operating conditions unknown.

P&ID NC 9321-F-27293 Report No. 0700.104-17, Appendix C, Revision 2 Page C-6 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Steam Generator Blowdown (BD), Unit 3 Section B: SNM Program Lines 3-BD-01: Steam Generator Blowdown to Blowdown Tank and Sample Cooler Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-BD-037 4

S SG 31 Blowdown to SGB Heat Exchangers Operating conditions unknown.

P&ID NC 9321-F-27293 Text19:

3-BD-038 4

S SG 32 Blowdown to SGB Heat Exchangers Operating conditions unknown.

P&ID NC 9321-F-27293 Text19:

3-BD-039 4

S SG 33 Blowdown to SGB Heat Exchangers Operating conditions unknown.

P&ID NC 9321-F-27293 Text19:

3-BD-040 4

S SG 34 Blowdown to SGB Heat Exchangers Operating conditions unknown.

P&ID NC 9321-F-27293 Text19:

3-BD-045 4

S Header from SG 34 and SG 33 Blowdown to SGB Heat Exchangers Operating conditions unknown.

P&ID NC 9321-F-27293 Text19:

3-BD-046 4

S Header from SG 31, 33, and 34 Blowdown to SGB Heat Exchangers Operating conditions unknown.

P&ID NC 9321-F-27293 Text19:

3-BD-047 4

S Header from SG Blowdown to SGB Heat Exchangers Operating conditions unknown.

P&ID NC 9321-F-27293, 9321-F-24063 Text19:

3-BD-048 18 S

Blowdown Tank vent to Atmosphere Operating conditions unknown.

P&ID NC 9321-F-27293 Text19:

3-BD-052 4

S Steam Generator Blowdown upstream of SGB Heat Exchanger #3 Operating conditions unknown.

P&ID NC 9321-F-24063 Text19:

3-BD-053 4

S Steam Generator Blowdown downstream of SGB Heat Exchanger

  1. 3 before Orifice Operating conditions unknown.

P&ID NC 9321-F-24063 Text19:

3-BD-055 4

S SG Blowdown from Orifice upstream of Heat Exchanger #4 (A and B)

Operating conditions unknown.

P&ID NC 9321-F-24063 Text19:

3-BD-056 4

S SG Blowdown downstream of HE #4 (A and B) to PCV 2 Operating conditions unknown.

P&ID NC 9321-F-24063 Text19:

3-BD-058 4

S SG Blowdown from PCV 2 to Pre-filters Operating conditions unknown.

P&ID NC 9321-F-24063 Text19:

3-BD-063 4

S SG Blowdown upstream of SGBDF-2 Operating conditions unknown.

P&ID NC 9321-F-24063 Report No. 0700.104-17, Appendix C, Revision 2 Page C-7 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Steam Generator Blowdown (BD), Unit 3 Section B: SNM Program Lines 3-BD-01: Steam Generator Blowdown to Blowdown Tank and Sample Cooler Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-BD-065 4

S SGBDF-2 to SGBDF-4 Operating conditions unknown.

P&ID NC 9321-F-24063 Text19:

3-BD-068 4

S SGBDF-4 to Ion Exchanger header Operating conditions unknown.

P&ID NC 9321-F-24063 Text19:

3-BD-069 4

S SG Blowdown header to Ion Exchangers (SGBDIX)

Operating conditions unknown.

P&ID NC 9321-F-24063 Text19:

3-BD-070 4

S SG Blowdown to SGBDIX-1 Operating conditions unknown.

P&ID NC 9321-F-24063 Text19:

3-BD-073 4

S SGBDIX-1 Drain header Operating conditions unknown.

P&ID NC 9321-F-24063 Text19:

3-BD-074 4

S SGBDIX-2 Drain to Resin Trap Operating conditions unknown.

P&ID NC 9321-F-24063 Text19:

3-BD-075 4

S SGBDIX-3 Drain to Resin Trap Operating conditions unknown.

P&ID NC 9321-F-24063 Text19:

3-BD-076 4

S SGBDIX-1 Drain to SGBDIX header Operating conditions unknown.

P&ID NC 9321-F-24063 Text19:

3-BD-077 4

S SGBDIX-2 Drain to SGBDIX header Operating conditions unknown.

P&ID NC 9321-F-24063 Text19:

3-BD-079 4

S SGBDIX-1 Drain upstream of SGBDIX-2 Operating conditions unknown.

P&ID NC 9321-F-24063 Text19:

3-BD-080 4

S SGBDIX-1 Drain upstream of SGBDIX-3 Operating conditions unknown.

P&ID NC 9321-F-24063 Text19:

3-BD-082 4

S SGBDIX-2 Drain upstream of SGBDIX-3 Operating conditions unknown.

P&ID NC 9321-F-24063 Text19:

3-BD-085 4

S SG Blowdown to SGBDIX-2 downstream of SGBDIX-1 drain Operating conditions unknown.

P&ID NC 9321-F-24063 Text19:

3-BD-086 4

S SG Blowdown to SGBDIX-3 downstream of SGBDIX-1 and SGBDIX-2 drain Operating conditions unknown.

P&ID NC 9321-F-24063 Text19:

3-BD-088 4

S SGBDIX-2 Resin Trap to Post Filter header Operating conditions unknown.

P&ID NC 9321-F-24063 Text19:

3-BD-089 4

S SGBDIX-3 Resin Trap to Post Filter header Operating conditions unknown.

P&ID NC 9321-F-24063 Report No. 0700.104-17, Appendix C, Revision 2 Page C-8 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Steam Generator Blowdown (BD), Unit 3 Section B: SNM Program Lines 3-BD-01: Steam Generator Blowdown to Blowdown Tank and Sample Cooler Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-BD-096 4

S SGBDIX-2 and 3 header to Post Filters Operating conditions unknown.

P&ID NC 9321-F-24063 Text19:

3-BD-097 4

S SGBDIX header to Post Filters Operating conditions unknown.

P&ID NC 9321-F-24063 Text19:

3-BD-100 4

S SG Blowdown to SGBDIX-5 Operating conditions unknown.

P&ID NC 9321-F-24063 Text19:

3-BD-101 4

S SG Blowdown to SGBDIX-6 Operating conditions unknown.

P&ID NC 9321-F-24063 Text19:

3-BD-102 4

S SGBDIX-5 header to Drain Collecting Tank Operating conditions unknown.

P&ID NC 9321-F-24063 Text19:

3-BD-103 4

S SGBDIX-6 header to Drain Collecting Tank Operating conditions unknown.

P&ID NC 9321-F-24063 Text19:

3-BD-104 4

S SG Blowdown to Drain Collecting Tank Operating conditions unknown.

P&ID NC 9321-F-24063, 9321-F-20183 Sheet 1 Section C: Excluded Lines 3-BD-01: Steam Generator Blowdown to Blowdown Tank and Sample Cooler Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-BD-003 2.5 E

SG 32 Blowdown via BD-1-4 Stainless Steel Piping P&ID EM 9321-F-27293 Text19:

3-BD-005 2.5 E

SG 32 Blowdown via BD-1-3 Stainless Steel Piping P&ID EM 9321-F-27293 Text19:

3-BD-007 2.5 E

SG 33 Blowdown via BD-1-6 Stainless Steel Piping P&ID EM 9321-F-27293 Text19:

3-BD-009 2.5 E

SG 33 Blowdown via BD-1-5 Stainless Steel Piping P&ID EM 9321-F-27293 Text19:

3-BD-014 1

E SG 32 Shell Drain Stainless Steel Piping P&ID EM 9321-F-27293 Text19:

3-BD-016 1

E SG 33 Shell Drain Stainless Steel Piping P&ID EM 9321-F-27293 Text19:

3-BD-018 1

E SG 34 Shell Drain Stainless Steel Piping P&ID EM 9321-F-27293 Report No. 0700.104-17, Appendix C, Revision 2 Page C-9 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Steam Generator Blowdown (BD), Unit 3 Section C: Excluded Lines 3-BD-01: Steam Generator Blowdown to Blowdown Tank and Sample Cooler Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-BD-028 4

E SG 31 Blowdown to SGB Flash Tank No 31 Valve shown closed on P&ID.

P&ID EI 9321-F-27293 Text19:

3-BD-029 4

E SG 32 Blowdown to SGB Flash Tank No 31 Valve shown closed on P&ID.

P&ID EI 9321-F-27293 Text19:

3-BD-030 4

E SG 33 Blowdown to SGB Flash Tank No 31 Valve shown closed on P&ID.

P&ID EI 9321-F-27293 Text19:

3-BD-031 4

E SG 34 Blowdown to SGB Flash Tank No 31 Valve shown closed on P&ID.

P&ID EI 9321-F-27293 Text19:

3-BD-032 2

E SG 31 Blowdown to Liquid Waste System Valve shown closed on P&ID.

P&ID EI 9321-F-27293 Text19:

3-BD-033 2

E SG 32 Blowdown to Liquid Waste System Valve shown closed on P&ID.

P&ID EI 9321-F-27293 Text19:

3-BD-034 2

E SG 33 Blowdown to Liquid Waste System Valve shown closed on P&ID.

P&ID EI 9321-F-27293 Text19:

3-BD-035 2

E SG 34 Blowdown to Liquid Waste System Valve shown closed on P&ID.

P&ID EI 9321-F-27293 Text19:

3-BD-036 3

E SG Blowdown header to Liquid Waste System Valve shown closed on P&ID.

P&ID EI 9321-F-27293 Text19:

3-BD-041 4

E SG 31 Blowdown HCV-1 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-27293 Text19:

3-BD-042 4

E SG 32 Blowdown HCV-2 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-27293 Text19:

3-BD-043 4

E SG 33 Blowdown HCV-3 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-27293 Text19:

3-BD-044 4

E SG 34Blowdown HCV-4 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-27293 Text19:

3-BD-049 0.38 E

Line to Sample Cooler from Blowdown Tank Vent via BD-220 Sample lines are SS TS-MS-024 EM 9321-F-27293 Text19:

3-BD-050 2

E Steam Generator Blowdown Flash Tank drain Valve shown closed on P&ID.

P&ID EI 9321-F-27293 Report No. 0700.104-17, Appendix C, Revision 2 Page C-10 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Steam Generator Blowdown (BD), Unit 3 Section C: Excluded Lines 3-BD-01: Steam Generator Blowdown to Blowdown Tank and Sample Cooler Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-BD-051 4

E Blowdown drain to SW drain Valve shown closed on P&ID.

P&ID EI 9321-F-27293, 9321-F-24063 Text19:

3-BD-054 4

E SG Blowdown HE #3 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-24063 Text19:

3-BD-057 4

E SG Blowdown HE #4 (A and B)

Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-24063 Text19:

3-BD-059 4

E PCV 2 Bypass line Valve shown closed on P&ID.

P&ID EI 9321-F-24063 Text19:

3-BD-060 4

E SG Blowdown Pre-filter and Ion Exchanger Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-24063 Text19:

3-BD-061 2

E SG Blowdown Relief Valve to Atmosphere Low to no flow in vent to atmosphere P&ID EF 9321-F-24063 Text19:

3-BD-062 4

E SG Blowdown upstream of SGBDF-1 Valve shown closed on P&ID.

P&ID EI 9321-F-24063 Text19:

3-BD-064 4

E SGBDF-1 to SGBDF-3 Valve shown closed on P&ID.

P&ID EI 9321-F-24063 Text19:

3-BD-066 4

E SGBDF Balance Line Valve shown closed on P&ID.

P&ID EI 9321-F-24063 Text19:

3-BD-067 4

E SGBDF-3 to Ion Exchanger header Valve shown closed on P&ID.

P&ID EI 9321-F-24063 Text19:

3-BD-071 4

E SG Blowdown to SGBDIX-2 Valve shown closed on P&ID.

P&ID EI 9321-F-24063 Text19:

3-BD-072 4

E SG Blowdown to SGBDIX-3 Valve shown closed on P&ID.

P&ID EI 9321-F-24063 Text19:

3-BD-078 4

E SGBDIX-3 Drain to SGBDIX header Valve shown closed on P&ID.

P&ID EI 9321-F-24063 Text19:

3-BD-081 4

E SGBDIX-2 Drain upstream of SGBDIX-1 Valve shown closed on P&ID.

P&ID EI 9321-F-24063 Text19:

3-BD-083 4

E SGBDIX-3 Drain upstream of SGBDIX-1 Valve shown closed on P&ID.

P&ID EI 9321-F-24063 Text19:

3-BD-084 4

E SGBDIX-3 Drain upstream of SGBDIX-2 Valve shown closed on P&ID.

P&ID EI 9321-F-24063 Report No. 0700.104-17, Appendix C, Revision 2 Page C-11 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Steam Generator Blowdown (BD), Unit 3 Section C: Excluded Lines 3-BD-01: Steam Generator Blowdown to Blowdown Tank and Sample Cooler Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-BD-087 4

E SGBDIX-1 Resin Trap to Post Filter header Valve shown closed on P&ID.

P&ID EI 9321-F-24063 Text19:

3-BD-090 2

E SGBDIX-1 Resin Rinse to Drain Valve shown closed on P&ID.

P&ID EI 9321-F-24063 Text19:

3-BD-091 2

E SGBDIX-2 Resin Rinse to Drain Valve shown closed on P&ID.

P&ID EI 9321-F-24063 Text19:

3-BD-092 2

E SGBDIX-3 Resin Rinse to Drain Valve shown closed on P&ID.

P&ID EI 9321-F-24063 Text19:

3-BD-093 4

E SGBDIX-1 Drain to Resin Trap Valve shown closed on P&ID.

P&ID EI 9321-F-24063 Text19:

3-BD-094 2

E SGBDIX-1 and 2 Resin Rinse to Drain Valve shown closed on P&ID.

P&ID EI 9321-F-24063 Text19:

3-BD-095 2

E SGBDIX Resin Rinse to Drain Valve shown closed on P&ID.

P&ID EI 9321-F-24063 Text19:

3-BD-098 1.5 E

Post Filter Bypass to Recycle Pump Valve shown closed on P&ID.

P&ID EI 9321-F-24063 Text19:

3-BD-099 2

E Recycle Pump exit to SGBDIX header Valve shown closed on P&ID.

P&ID EI 9321-F-24063 Report No. 0700.104-17, Appendix C, Revision 2 Page C-12 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Pump Discharge (CD), Unit 3 Section A: CHECWORKS Model Lines 3-CD-02: Condensate Lines Downstream of #32 Feedwater Heaters Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-CD-001 14 M

CD-02.1A FWH 32A to HDR:

Condensate from FWH 32-A to Condensate Header PEPSE 9321-F-20183 Sheet 1 Text19:

3-CD-002 14 M

CD-02.1B FWH 32B to HDR:

Condensate from FWH 32-B to Condensate Header PEPSE 9321-F-20183 Sheet 1 Text19:

3-CD-003 14 M

CD-02.1C FWH 32C to HDR:

Condensate from FWH 32-C to Condensate Header PEPSE 9321-F-20183 Sheet 1 Text19:

3-CD-004 20 M

CD-02.2 FWH 32 OUT HDR:

Condensate Header from FWHs 32-A and 32-B PEPSE 9321-F-20183 Sheet 1 Text19:

3-CD-005 24 M

CD-02.3 FWH 32 OUT HDR:

Condensate Header to #33 FWHs PEPSE 9321-F-20183 Sheet 1, 9321-F-20183 Sheet 2 Text19:

3-CD-006 24 M

CD-02.4 FWH 32 OUT HDR:

Condensate line to #33 FWHs PEPSE 9321-F-20183 Sheet 2 Text19:

3-CD-007 8

M CD-02.11 SGBD HX3 to FWH HDR:

Condensate to Steam Generator Blowdown HE #3 PEPSE 9321-F-20183 Sheet 2 Text19:

3-CD-008 8

M CD-02.5 FWH 32 OUT HDR:

Condensate from Steam Generator Blowdown HE #3 tube side to #33 FWHs PEPSE 9321-F-20183 Sheet 2 Text19:

3-CD-010 24 M

CD-02.9 FWH HDR to SGBD HX3:

Condensate line to #33 FWHs PEPSE 9321-F-20183 Sheet 2 Text19:

3-CD-013 24 M

CD-02.6 FWH 32 OUT HDR:

Condensate Header to FWHs 33-A and 33-B PEPSE 9321-F-20183 Sheet 2 Text19:

3-CD-017 14 M

CD-02.8C HDR to FWH 33C:

Condensate line to FWH 33-C PEPSE 9321-F-20183 Sheet 2 Report No. 0700.104-17, Appendix C, Revision 2 Page C-13 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Pump Discharge (CD), Unit 3 Section A: CHECWORKS Model Lines 3-CD-02: Condensate Lines Downstream of #32 Feedwater Heaters Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-CD-018 14 M

CD-02.8B HDR to FWH 33B:

Condensate line to FWH 33-B PEPSE 9321-F-20183 Sheet 2 Text19:

3-CD-019 14 M

CD-02.8A HDR to FWH 33A:

Condensate line to FWH 33-A PEPSE 9321-F-20183 Sheet 2 Text19:

3-CD-020 14 M

CD-03.1A FWH 33A to FWH 34A:

Condensate line to FWH 34-A PEPSE 9321-F-20183 Sheet 2 Text19:

3-CD-021 14 M

CD-03.1B FWH 33B to FWH 34B:

Condensate line to FWH 34-B PEPSE 9321-F-20183 Sheet 2 Text19:

3-CD-022 14 M

CD-03.1C FWH 33C to FWH 34C:

Condensate line to FWH 34-C PEPSE 9321-F-20183 Sheet 2 Text19:

3-CD-023 14 M

CD-04.1A FWH 34A to FWH 35A:

Condensate line to FWH 35-A PEPSE 9321-F-20183 Sheet 2 Text19:

3-CD-024 14 M

CD-04.1B FWH 34B to FWH 35B:

Condensate line to FWH 35-B PEPSE 9321-F-20183 Sheet 2 Text19:

3-CD-025 14 M

CD-04.1C FWH 34C to FWH 35C:

Condensate line to FWH 35-C PEPSE 9321-F-20183 Sheet 2 Text19:

3-CD-026 14 M

CD-05.1A FWH 35A to HDR:

Condensate from FWH 35-A to Condensate Header PEPSE 9321-F-20183 Sheet 2 Text19:

3-CD-027 14 M

CD-05.1B FWH 35B to HDR:

Condensate from FWH 35-B to Condensate Header PEPSE 9321-F-20183 Sheet 2 Text19:

3-CD-028 14 M

CD-05.1C FWH 35C to HDR:

Condensate from FWH 35-C to Condensate Header PEPSE 9321-F-20183 Sheet 2 Text19:

3-CD-029 24 M

CD-05.3 FWH 35 OUT HDR:

Condensate header from FWHs 35-A and 35-B PEPSE 9321-F-20183 Sheet 2 Report No. 0700.104-17, Appendix C, Revision 2 Page C-14 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Pump Discharge (CD), Unit 3 Section A: CHECWORKS Model Lines 3-CD-02: Condensate Lines Downstream of #32 Feedwater Heaters Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-CD-030 24 M

CD-05.4 FWH 35 OUT HDR:

Condensate Header to BFPs Upstream of Heater Drain Pump inlet PEPSE 9321-F-20183 Sheet 2 Text19:

3-CD-031 30 M

CD-06.1 FWH 35 OUT HDR:

Condensate Header to BFPs Downstream of Heater Drain Pump inlet PEPSE 9321-F-20183 Sheet 2 Text19:

3-CD-032 24 M

CD-06.2A HDR to BFP 31:

Condensate from Header to BFP No.

31 PEPSE 9321-F-20183 Sheet 2, 9321-F-20193 Text19:

3-CD-033 24 M

CD-06.2B HDR to BFP 32:

Condensate from Header to BFP No.

32 PEPSE 9321-F-20183 Sheet 2, 9321-F-20193 Section C: Excluded Lines 3-CD-02: Condensate Lines Downstream of #32 Feedwater Heaters Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-CD-009 1.5 E

CD-13 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-20183 Sheet 2 Text19:

3-CD-011 12 E

Feedwater Bypass line Valve shown closed on P&ID. FCV-1115/1116 leaking-by P&ID EI 9321-F-20183 Sheet 2 Text19:

3-CD-012 1.5 E

CD-19 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-20183 Sheet 2 Text19:

3-CD-014 1.5 E

CD-16-3 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-20183 Sheet 2 Text19:

3-CD-015 1.5 E

CD-16-2 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-20183 Sheet 2 Text19:

3-CD-016 1.5 E

CD-16-1 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-20183 Sheet 2 Text19:

3-CD-034 2

E CD-21-2 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-20183 Sheet 2 Report No. 0700.104-17, Appendix C, Revision 2 Page C-15 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Pump Discharge (CD), Unit 3 Section C: Excluded Lines 3-CD-02: Condensate Lines Downstream of #32 Feedwater Heaters Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-CD-035 2

E CD-21-1 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-20183 Sheet 2 Report No. 0700.104-17, Appendix C, Revision 2 Page C-16 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Storage & Transfer (CT), Unit 3 Section B: SNM Program Lines 3-CT-01: Lines from the Boiler Feed Pump Turbine Drip Tank to the Drip Tank Drain Pumps Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-CT-001 3

S Drain header to BFPT Drain Pumps Operating conditions unknown.

P&ID NC 9321-F-20243 Text19:

3-CT-002 3

S Drain to BFPT Drain Pump No 31 Operating conditions unknown.

P&ID NC 9321-F-20243 Text19:

3-CT-003 3

S Drain to BFPT Drain Pump No 32 Operating conditions unknown.

P&ID NC 9321-F-20243 Report No. 0700.104-17, Appendix C, Revision 2 Page C-17 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Extraction Steam Traps (EST), Unit 3 Section B: SNM Program Lines 3-3EST-01: LP Turbine Extraction Steam to #33 FWHs Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-3EST-016-A 2

S Extraction Steam to EST-14 Operating conditions unknown.

P&ID NS 9321-F-20313 Text19:

3-3EST-016-B 2

S EST-14 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20313 Text19:

3-3EST-017-A 2

S Extraction Steam to EST-15 Operating conditions unknown.

P&ID NS 9321-F-20313 Text19:

3-3EST-017-B 0.75 S

EST-15 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20313 Text19:

3-3EST-018-A 0.75 S

Extraction Steam to EST-16 Operating conditions unknown.

P&ID NS 9321-F-20313 Text19:

3-3EST-018-B 0.75 S

EST-16 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20313 Text19:

3-3EST-019-A 2

S Extraction Steam to EST-17 Operating conditions unknown.

P&ID NS 9321-F-20313 Text19:

3-3EST-019-B 2

S EST-17 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20313 Text19:

3-3EST-020-A 0.75 S

Extraction Steam to EST-18 Operating conditions unknown.

P&ID NS 9321-F-20313 Text19:

3-3EST-020-B 0.75 S

EST-18 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20313 Text19:

3-3EST-021-A 0.75 S

Extraction Steam to EST-19 Operating conditions unknown.

P&ID NS 9321-F-20313 Text19:

3-3EST-021-B 0.75 S

EST-19 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20313 Text19:

3-3EST-022-A 2

S Extraction Steam to EST-20 Operating conditions unknown.

P&ID NS 9321-F-20313 Text19:

3-3EST-022-B 2

S EST-20 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20313 Text19:

3-3EST-023-A 0.75 S

Extraction Steam to EST-21 Operating conditions unknown.

P&ID NS 9321-F-20313 Text19:

3-3EST-023-B 0.75 S

EST-21 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20313 Text19:

3-3EST-024-A 0.75 S

Extraction Steam to EST-22 Operating conditions unknown.

P&ID NS 9321-F-20313 Text19:

3-3EST-024-B 0.75 S

EST-22 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20313 Report No. 0700.104-17, Appendix C, Revision 2 Page C-18 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Extraction Steam Traps (EST), Unit 3 Section B: SNM Program Lines 3-4EST-02: Steam Traps to the Steam Trap Drains Header from Extraction lines to #34 FWHs Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-4EST-001 0.75 S

EST-5 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20313 Text19:

3-4EST-002 0.75 S

EST-6 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20313 Text19:

3-4EST-003 0.75 S

EST-7 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20313 Text19:

3-4EST-004 0.75 S

EST-8 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20313 Text19:

3-4EST-005 0.75 S

EST-9 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20313 Text19:

3-4EST-006 0.75 S

EST-10 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20313 Text19:

3-4EST-007 0.75 S

EST-11 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20313 Text19:

3-4EST-008 0.75 S

EST-12 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20313 Text19:

3-4EST-009 0.75 S

EST-13 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20313 3-5EST-01: Extraction Steam to #35 FWHs Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-5EST-020 0.75 S

H.P. Turbine crossunder piping through steam trap LPT 7 Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Text19:

3-5EST-021 0.75 S

H.P. Turbine crossunder piping steam trap bypass Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Text19:

3-5EST-022 0.75 S

Steam Trap LPT-7 Drain Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Text19:

3-5EST-026 0.75 S

H.P. Turbine crossunder piping through steam trap LPT 6 Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Text19:

3-5EST-027 0.75 S

H.P. Turbine crossunder piping steam trap bypass Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Text19:

3-5EST-028 0.75 S

Steam Trap LPT-6 Drain Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Report No. 0700.104-17, Appendix C, Revision 2 Page C-19 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Extraction Steam Traps (EST), Unit 3 Section B: SNM Program Lines 3-5EST-01: Extraction Steam to #35 FWHs Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-5EST-032 0.75 S

H.P. Turbine crossunder piping through steam trap LPT 9 Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Text19:

3-5EST-033 0.75 S

H.P. Turbine crossunder piping steam trap bypass Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Text19:

3-5EST-034 0.75 S

Steam Trap LPT-9 Drain Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Text19:

3-5EST-038 0.75 S

H.P. Turbine crossunder piping through steam trap LPT 8 Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Text19:

3-5EST-039 0.75 S

H.P. Turbine crossunder piping steam trap bypass Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Text19:

3-5EST-040 0.75 S

Steam Trap LPT-8 Drain Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Text19:

3-5EST-044 0.75 S

H.P. Turbine crossunder piping through steam trap LPT 11 Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Text19:

3-5EST-045 0.75 S

H.P. Turbine crossunder piping steam trap bypass Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Text19:

3-5EST-046 0.75 S

H.P. Turbine crossunder piping to Condenser 33 Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Text19:

3-5EST-050 0.75 S

H.P. Turbine crossunder piping through steam trap LPT 10 Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Text19:

3-5EST-051 0.75 S

H.P. Turbine crossunder piping steam trap bypass Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Text19:

3-5EST-052 0.75 S

H.P. Turbine crossunder piping to Condenser 33 Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Text19:

3-5EST-072-A 2

S Extraction Steam to EST-3 Operating conditions unknown.

P&ID NC 9321-F-20313 Text19:

3-5EST-072-B 0.75 S

EST-3 to Steam Trap Header Operating conditions unknown.

P&ID NC 9321-F-20313 Text19:

3-5EST-073-A 2

S Extraction Steam to EST-23 Operating conditions unknown.

P&ID NC 9321-F-20313 Report No. 0700.104-17, Appendix C, Revision 2 Page C-20 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Extraction Steam Traps (EST), Unit 3 Section B: SNM Program Lines 3-5EST-01: Extraction Steam to #35 FWHs Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-5EST-073-B 1

S EST-23 to Steam Trap Header Operating conditions unknown.

P&ID NC 9321-F-20313 Text19:

3-5EST-074-A 2

S Extraction Steam to EST-4 Operating conditions unknown.

P&ID NC 9321-F-20313 Text19:

3-5EST-074-B 1

S EST-4 to Steam Trap Header Operating conditions unknown.

P&ID NC 9321-F-20313 3-6EST-01: HP Turbine Extraction Steam to Extraction Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-6EST-015 2

S Extraction Steam to EST-1 and EST-1A Flow Conditions Unknown P&ID NS 9321-F-20313 Text19:

3-6EST-016 2

S Extraction Steam to EST-1 Flow Conditions Unknown P&ID NS 9321-F-20313 Text19:

3-6EST-017 2

S Extraction Steam to EST-1A Flow Conditions Unknown P&ID NS 9321-F-20313 Text19:

3-6EST-018 2

S EST-1 to Steam Trap Header Flow Conditions Unknown P&ID NS 9321-F-20313 Text19:

3-6EST-019 2

S EST-1A to Steam Trap Header Flow Conditions Unknown P&ID NS 9321-F-20313 Text19:

3-6EST-022 0.75 S

Extraction Steam to EST-2 Flow Conditions Unknown P&ID NS 9321-F-20313 Text19:

3-6EST-023 0.75 S

EST-2 to Steam Trap Header Flow Conditions Unknown P&ID NS 9321-F-20313 3-6EST-02: Extraction Steam Trap Drain Headers to the Drains Collecting Tank Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-6EST-026 6

S Drain Header from Extraction Steam Traps Operating conditions unknown.

P&ID NC 9321-F-20313 Report No. 0700.104-17, Appendix C, Revision 2 Page C-21 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Extraction Steam Traps (EST), Unit 3 Section C: Excluded Lines 3-3EST-01: LP Turbine Extraction Steam to #33 FWHs Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-3EST-016-C E

EST-14 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20313 Text19:

3-3EST-017-C E

EST-15 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20313 Text19:

3-3EST-018-C E

EST-16 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20313 Text19:

3-3EST-019-C E

EST-17 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20313 Text19:

3-3EST-020-C E

EST-18 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20313 Text19:

3-3EST-021-C E

EST-19 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20313 Text19:

3-3EST-022-C E

EST-20 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20313 Text19:

3-3EST-023-C E

EST-21 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20313 Text19:

3-3EST-024-C E

EST-22 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20313 3-5EST-01: Extraction Steam to #35 FWHs Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-5EST-072-C 0.75 E

EST-3 Bypass Line Valve shown closed on P&ID.

9321-F-20313 EI 9321-F-20313 Text19:

3-5EST-073-C 0.75 E

EST-23 Bypass Line Valve shown closed on P&ID.

9321-F-20313 EI 9321-F-20313 Text19:

3-5EST-074-C 1

E EST-4 Bypass Line Valve shown closed on P&ID.

9321-F-20313 EI 9321-F-20313 3-6EST-01: HP Turbine Extraction Steam to Extraction Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-6EST-020 2

E EST-1 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20313 Text19:

3-6EST-021 2

E EST-1A Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20313 Text19:

3-6EST-024 0.75 E

EST-2 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20313 Report No. 0700.104-17, Appendix C, Revision 2 Page C-22 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Extraction Steam Traps (EST), Unit 3 Section C: Excluded Lines 3-6EST-02: Extraction Steam Trap Drain Headers to the Drains Collecting Tank Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-6EST-025 4

E Drain from EST 1, 1A, 2, 3, 4, and 23 to Drain Collecting Tank Replaced with Chrome-moly IP3-RPT-MULT-03162 EM 9321-F-20313 Report No. 0700.104-17, Appendix C, Revision 2 Page C-23 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Extraction Steam (EX), Unit 3 Section A: CHECWORKS Model Lines 3-1EX-01: LP Turbine Extraction Steam to #31 Feedwater Heaters Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-1EX-001 26 M

EX-06.3A LP EXT 20 to FWH 31A:

No. 20 Extraction Steam to FWH 31A PEPSE 9321-F-20203 Sheet 2 Text19:

3-1EX-002 26 M

EX-06.1A LP EXT 19 to FWH 31A:

No. 19 Extraction Steam to FWH 31A PEPSE 9321-F-20203 Sheet 2 Text19:

3-1EX-003 26 M

EX-06.2A LP EXT 17 to FWH 31A:

No. 17 Extraction Steam to FWH 31A PEPSE 9321-F-20203 Sheet 2 Text19:

3-1EX-004 26 M

EX-06.4A LP EXT 18 to FWH 31A:

No. 18 Extraction Steam to FWH 31A PEPSE 9321-F-20203 Sheet 2 Text19:

3-1EX-005 26 M

EX-06.3B LP EXT 20 to FWH 31B:

No. 20 Extraction Steam to FWH 31B PEPSE 9321-F-20203 Sheet 2 Text19:

3-1EX-006 26 M

EX-06.1B LP EXT 19 to FWH 31B:

No. 19 Extraction Steam to FWH 31B PEPSE 9321-F-20203 Sheet 2 Text19:

3-1EX-007 26 M

EX-06.2B LP EXT 17 to FWH 31B:

No. 17 Extraction Steam to FWH 31B PEPSE 9321-F-20203 Sheet 2 Text19:

3-1EX-008 26 M

EX-06.4B LP EXT 18 to FWH 31B:

No. 18 Extraction Steam to FWH 31B PEPSE 9321-F-20203 Sheet 2 Text19:

3-1EX-009 26 M

EX-06.3C LP EXT 20 to FWH 31C:

No. 20 Extraction Steam to FWH 31C PEPSE 9321-F-20203 Sheet 2 Text19:

3-1EX-010 26 M

EX-06.1C LP EXT 19 to FWH 31C:

No. 19 Extraction Steam to FWH 31C PEPSE 9321-F-20203 Sheet 2 Text19:

3-1EX-011 26 M

EX-06.2C LP EXT 17 to FWH 31C:

No. 17 Extraction Steam to FWH 31C PEPSE 9321-F-20203 Sheet 2 Text19:

3-1EX-012 26 M

EX-06.4C LP EXT 18 to FWH 31C:

No. 18 Extraction Steam to FWH 31C PEPSE 9321-F-20203 Sheet 2 Report No. 0700.104-17, Appendix C, Revision 2 Page C-24 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Extraction Steam (EX), Unit 3 Section A: CHECWORKS Model Lines 3-2EX-01: LP Turbine Extraction Steam to #32 Feedwater Heaters Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-2EX-001 22 M

EX-05.1A LP EXT 16 to FWH 32A:

No. 16 Extraction Steam to FWH 32A PEPSE 9321-F-20203 Sheet 2 Text19:

3-2EX-002 22 M

EX-05.2A LP EXT 15 to FWH 32A:

No. 15 Extraction Steam to FWH 32A PEPSE 9321-F-20203 Sheet 2 Text19:

3-2EX-003 22 M

EX-05.1B LP EXT 16 to FWH 32B:

No. 16 Extraction Steam to FWH 32B PEPSE 9321-F-20203 Sheet 2 Text19:

3-2EX-004 22 M

EX-05.2B LP EXT 15 to FWH 32B:

No. 15 Extraction Steam to FWH 32B PEPSE 9321-F-20203 Sheet 2 Text19:

3-2EX-005 22 M

EX-05.1C LP EXT 16 to FWH 32C:

No. 16 Extraction Steam to FWH 32C PEPSE 9321-F-20203 Sheet 2 Text19:

3-2EX-006 22 M

EX-05.2C LP EXT 15 to FWH 32C:

No. 15 Extraction Steam to FWH 32C PEPSE 9321-F-20203 Sheet 2 3-3EX-01: LP Turbine Extraction Steam to #33 Feedwater Heaters Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-3EX-001 20 M

EX-04.1 LPEX14 to FWH33A HDR:

No. 14 Extraction Steam to FWH 33A PEPSE 9321-F-20203 Sheet 2 Text19:

3-3EX-002 20 M

EX-04.2 LPEX13 to FWH33A HDR:

No. 13 Extraction Steam to FWH 33A PEPSE 9321-F-20203 Sheet 2 Text19:

3-3EX-003 28 M

EX-04.4 LPEX FWH 33A IN HDR:

Extraction Steam header to FWH 33A PEPSE 9321-F-20203 Sheet 2 Text19:

3-3EX-004 20 M

EX-04.6 LP EXT to FWH 33A:

Extraction Steam to FWH 33A PEPSE 9321-F-20203 Sheet 2 Text19:

3-3EX-005 20 M

EX-04.7 LP EXT to FWH 33A:

Extraction Steam to FWH 33A PEPSE 9321-F-20203 Sheet 2 Text19:

3-3EX-006 20 M

EX-04.8 LPEX14 to FWH33B HDR:

No. 14 Extraction Steam to FWH 33B PEPSE 9321-F-20203 Sheet 2 Report No. 0700.104-17, Appendix C, Revision 2 Page C-25 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Extraction Steam (EX), Unit 3 Section A: CHECWORKS Model Lines 3-3EX-01: LP Turbine Extraction Steam to #33 Feedwater Heaters Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-3EX-007 20 M

EX-04.9 LPEX13 to FWH33B HDR:

No. 13 Extraction Steam to FWH 33B PEPSE 9321-F-20203 Sheet 2 Text19:

3-3EX-008 28 M

EX-04.11 LPEX FWH 33B IN HDR:

Extraction Steam header to FWH 33B PEPSE 9321-F-20203 Sheet 2 Text19:

3-3EX-009 20 M

EX-04.13 LP EXT 32 to FWH 33B:

Extraction Steam to FWH 33B PEPSE 9321-F-20203 Sheet 2 Text19:

3-3EX-010 20 M

EX-04.14 LP EXT 32 to FWH 33B:

Extraction Steam to FWH 33B PEPSE 9321-F-20203 Sheet 2 Text19:

3-3EX-011 20 M

EX-04.15 LPEX14 to FWH33C HDR:

No. 14 Extraction Steam to FWH 33C PEPSE 9321-F-20203 Sheet 2 Text19:

3-3EX-012 20 M

EX-04.16 LPEX13 to FWH33C HDR:

No. 13 Extraction Steam to FWH 33C PEPSE 9321-F-20203 Sheet 2 Text19:

3-3EX-013 28 M

EX-04.18 LPEX FWH 33C IN HDR:

Extraction Steam header to FWH 33B PEPSE 9321-F-20203 Sheet 2 Text19:

3-3EX-014 20 M

EX-04.21 LP EXT 31 to FWH 33C:

Extraction Steam to FWH 33C PEPSE 9321-F-20203 Sheet 2 Text19:

3-3EX-015 20 M

EX-04.22 LP EXT 31 to FWH 33C:

Extraction Steam to FWH 33C PEPSE 9321-F-20203 Sheet 2 3-3EX-02: Boiler Feed Pump Turbine Drains to Condensers Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-3EX-025 48 M

BFP #31 Drain to Condenser PEPSE 9321-F-20173 Text19:

3-3EX-026 48 M

BFP #32 Drain to Condenser PEPSE 9321-F-20173 Report No. 0700.104-17, Appendix C, Revision 2 Page C-26 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Extraction Steam (EX), Unit 3 Section A: CHECWORKS Model Lines 3-5EX-02: Extraction Steam from Moisture Preseparators to #35 Feedwater Heaters Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-5EX-063 28 M

EX-02.14 FWH 35 HEADER:

Crossunder piping from Moisture Preseparators to #35 Feedwater Heaters PEPSE 9321-F-20203 Sheet 1 Section B: SNM Program Lines 3-3EX-02: Boiler Feed Pump Turbine Drains to Condensers Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-3EX-027 1.5 S

Continuous Drain to #31 Condenser Operating conditions unknown.

P&ID NC 9321-F-20243 Text19:

3-3EX-028 1.5 S

Continuous Drain to #32 Condenser Operating conditions unknown.

P&ID NC 9321-F-20243 3-5EX-01: HP Turbine Crossunder Piping Leakoff Drains to Condensers Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-5EX-001 2

S Drip Pot from Moisture Preseparator 1A to Heater Drain Tank Vent Operating conditions unknown.

PEPSE NC 9321-F-20203 Sheet 1, 9321-F-20223 Sheet 1 Text19:

3-5EX-002 2

S Drip Pot from Moisture Preseparator 2A to Heater Drain Tank Vent Operating conditions unknown.

PEPSE NC 9321-F-20203 Sheet 1, 9321-F-20223 Sheet 1 Text19:

3-5EX-003 2

S Drip Pot from Moisture Preseparator 1B to Heater Drain Tank Vent Operating conditions unknown.

PEPSE NC 9321-F-20203 Sheet 1, 9321-F-20223 Sheet 1 Text19:

3-5EX-004 2

S Drip Pot from Moisture Preseparator 2B to Heater Drain Tank Vent Operating conditions unknown.

PEPSE NC 9321-F-20203 Sheet 1, 9321-F-20223 Sheet 1 Text19:

3-5EX-019 10 S

H.P. Turbine crossunder piping header to Condenser 31 Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Text19:

3-5EX-024 12 S

H.P. Turbine crossunder piping to Condenser 31 Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Report No. 0700.104-17, Appendix C, Revision 2 Page C-27 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Extraction Steam (EX), Unit 3 Section B: SNM Program Lines 3-5EX-01: HP Turbine Crossunder Piping Leakoff Drains to Condensers Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-5EX-025 10 S

H.P. Turbine crossunder piping header to Condenser 31 Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Text19:

3-5EX-030 12 S

H.P. Turbine crossunder piping to Condenser 31 Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Text19:

3-5EX-031 10 S

H.P. Turbine crossunder piping header to Condenser 32 Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Text19:

3-5EX-036 12 S

H.P. Turbine crossunder piping to Condenser 32 Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Text19:

3-5EX-037 10 S

H.P. Turbine crossunder piping header to Condenser 32 Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Text19:

3-5EX-042 12 S

H.P. Turbine crossunder piping to Condenser 32 Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Text19:

3-5EX-043 10 S

H.P. Turbine crossunder piping header to Condenser 33 Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Text19:

3-5EX-048 12 S

H.P. Turbine crossunder piping to Condenser 33 Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Text19:

3-5EX-049 10 S

H.P. Turbine crossunder piping header to Condenser 33 Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Text19:

3-5EX-054 12 S

H.P. Turbine crossunder piping to Condenser 33 Flow Conditions Unknown PEPSE NC 9321-F-20203 Sheet 1 Text19:

3-5EX-076 1.5 S

Crossunder piping leakoff to FCV-1156 Operating conditions unknown.

P&ID NS 9321-05-FP-2355 Text19:

3-5EX-077 1.5 S

Crossunder piping leakoff to FCV-1164 Operating conditions unknown.

P&ID NS 9321-05-FP-2355 Text19:

3-5EX-078 1.5 S

Crossunder piping leakoff to FCV-1157 Operating conditions unknown.

P&ID NS 9321-05-FP-2355 Text19:

3-5EX-079 1.5 S

Crossunder piping leakoff to FCV-1165 Operating conditions unknown.

P&ID NS 9321-05-FP-2355 Report No. 0700.104-17, Appendix C, Revision 2 Page C-28 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Extraction Steam (EX), Unit 3 Section B: SNM Program Lines 3-5EX-01: HP Turbine Crossunder Piping Leakoff Drains to Condensers Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-5EX-080 S

Crossunder piping to Moisture Separator Outlet Line Operating conditions unknown.

P&ID NS 9321-05-FP-2355 Text19:

3-5EX-081 S

Crossunder piping to Moisture Separator Outlet Line Operating conditions unknown.

P&ID NS 9321-05-FP-2355 Text19:

3-5EX-082 S

Crossunder piping to Moisture Separator Outlet Line Operating conditions unknown.

P&ID NS 9321-05-FP-2355 Text19:

3-5EX-083 S

Crossunder piping to Moisture Separator Outlet Line Operating conditions unknown.

P&ID NS 9321-05-FP-2355 Text19:

3-5EX-085 1.5 S

Leakoff to Moisture Separation Operating conditions unknown.

P&ID NS 9321-05-FP-2355 3-5EX-02: Extraction Steam from Moisture Preseparators to #35 Feedwater Heaters Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-5EX-065-B 18 S

EX-02.16 HDR 35 to FWH 35A:

Feedwater Heater 35A Extraction Steam Inlet Nozzle This line represents the only susceptible component in the line.

IP3-RPT-MULT-03162, Rev.

3; SFA NL 9321-F-20203 Sheet 1 Text19:

3-5EX-066-B 18 S

EX-02.17 HDR 35 to FWH 35B:

Feedwater Heater 35B Extraction Steam Inlet Nozzle This line represents the only susceptible component in the line.

IP3-RPT-MULT-03162, Rev.

3; SFA NL 9321-F-20203 Sheet 1 Text19:

3-5EX-067-B 18 S

EX-02.19 HDR 35 to FWH 35C:

Feedwater Heater 35C Extraction Steam Inlet Nozzle This line represents the only susceptible component in the line.

IP3-RPT-MULT-03162, Rev.

3; SFA NL 9321-F-20203 Sheet 1 3-6EX-01: HP Turbine Extraction Steam to #36 Feedwater Heaters Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-6EX-001-A 12 S

EX-01.1 HP EXT to FWH 36 HDR:

HP Turbine Extraction Nozzle to #36 FWHs.

The nozzle is the only susceptible component in this line.

SFA Model NL 9321-F-20203 Sheet 1 Report No. 0700.104-17, Appendix C, Revision 2 Page C-29 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Extraction Steam (EX), Unit 3 Section B: SNM Program Lines 3-6EX-01: HP Turbine Extraction Steam to #36 Feedwater Heaters Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-6EX-002-A 12 S

EX-01.2 HP EXT to FWH 36 HDR:

HP Turbine Extraction Nozzle to #36 FWHs.

This nozzle is the only susceptible component in the line.

SFA Model NL 9321-F-20203 Sheet 1 Text19:

3-6EX-025 1

S FWH 36A Extraction Steam Line Drain Flow Conditions Unknown P&ID NS 9321-F-20203 Sheet 1 Text19:

3-6EX-026 1

S FWH 36B Extraction Steam Line Drain Flow Conditions Unknown P&ID NS 9321-F-20203 Sheet 1 Text19:

3-6EX-027 1.5 S

FWH 36A and 36B Extraction Steam Line Drain Header Flow Conditions Unknown P&ID NS 9321-F-20203 Sheet 1 Text19:

3-6EX-028 1

S FWH 36C Extraction Steam Line Drain Flow Conditions Unknown P&ID NS 9321-F-20203 Sheet 1 Text19:

3-6EX-029 2

S

  1. 36 FWH Extraction Steam Line Drain Header Flow Conditions Unknown P&ID NS 9321-F-20203 Sheet 1 Section C: Excluded Lines 3-5EX-01: HP Turbine Crossunder Piping Leakoff Drains to Condensers Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-5EX-023 10 E

H.P. Turbine crossunder to Condenser 31 FCV-1207 is shown closed on P&ID P&ID EI 9321-F-20203 Sheet 1 Text19:

3-5EX-029 10 E

H.P. Turbine crossunder to Condenser 31 FCV-1206 is shown closed on P&ID P&ID EI 9321-F-20203 Sheet 1 Text19:

3-5EX-035 10 E

H.P. Turbine crossunder to Condenser 32 FCV-1209 is shown closed on P&ID P&ID EI 9321-F-20203 Sheet 1 Text19:

3-5EX-041 10 E

H.P. Turbine crossunder to Condenser 32 FCV-1208 is shown closed on P&ID P&ID EI 9321-F-20203 Sheet 1 Report No. 0700.104-17, Appendix C, Revision 2 Page C-30 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Extraction Steam (EX), Unit 3 Section C: Excluded Lines 3-5EX-01: HP Turbine Crossunder Piping Leakoff Drains to Condensers Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-5EX-047 10 E

H.P. Turbine crossunder to Condenser 33 FCV-1211 is shown closed on P&ID P&ID EI 9321-F-20203 Sheet 1 Text19:

3-5EX-053 10 E

H.P. Turbine crossunder to Condenser 33 FCV-1210 is shown closed on P&ID P&ID EI 9321-F-20203 Sheet 1 Text19:

3-5EX-075 1.5 E

Line to Orifice Block Piping is Stainless Steel and Chrome-moly P&ID EM 9321-F-20203 Sheet 1, 9321-F-20173 Text19:

3-5EX-084 1.5 E

Balancing line leakoff to 3-MS-177 Replaced with Chrome-moly IP3-RPT-MULT-03162 EM 9321-05-FP-2355 3-5EX-02: Extraction Steam from Moisture Preseparators to #35 Feedwater Heaters Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-5EX-055 10 E

EX-02.2 PSEP 1A 10" to 35 HDR:

Crossunder piping header from Moisture Preseparator 1A to #35 FWH Line is clad with Stainless Steel IP3-RPT-MULT-03162, Rev.

3; SFA EM 9321-F-20203 Sheet 1 Text19:

3-5EX-056 10 E

EX-02.1 PSEP 2A 10" to 35 HDR:

Crossunder piping header from Moisture Preseparator 2A to #35 FWH Line is clad with Stainless Steel IP3-RPT-MULT-03162, Rev.

3; SFA EM 9321-F-20203 Sheet 1 Text19:

3-5EX-057 10 E

EX-02.9 PSEP 1B 10" to 35 HDR:

Crossunder piping header from Moisture Preseparator 1B to #35 FWH Line is clad with Stainless Steel IP3-RPT-MULT-03162, Rev.

3; SFA EM 9321-F-20203 Sheet 1 Text19:

3-5EX-058 10 E

EX-02.8 PSEP 2B 10" to 35 HDR:

Crossunder piping header from Moisture Preseparator 2B to #35 FWH Line is clad with Stainless Steel IP3-RPT-MULT-03162, Rev.

3; SFA EM 9321-F-20203 Sheet 1 Text19:

3-5EX-059 14 E

EX-02.4 PSEP2A 14" to 35 HDR:

Crossunder piping leakoff from Moisture Preseparator 2A to #35 FWH Line is clad with Stainless Steel IP3-RPT-MULT-03162, Rev.

3; SFA EM 9321-F-20203 Sheet 1 Report No. 0700.104-17, Appendix C, Revision 2 Page C-31 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Extraction Steam (EX), Unit 3 Section C: Excluded Lines 3-5EX-02: Extraction Steam from Moisture Preseparators to #35 Feedwater Heaters Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-5EX-060 14 E

EX-02.11 PSEP1B 14" to 35 HDR:

Crossunder piping leakoff from Moisture Preseparator 1B to #35 FWH Line is clad with Stainless Steel IP3-RPT-MULT-03162, Rev.

3; SFA EM 9321-F-20203 Sheet 1 Text19:

3-5EX-061 18 E

EX-02.6 PSEP 1A&2A to 35 HDR, EX-02.7 PSEP 1A&2A to 35 HDR:

Psep 2A to #35 FWHs Line is clad with Stainless Steel IP3-RPT-MULT-03162, Rev.

3; SFA EM 9321-F-20203 Sheet 1 Text19:

3-5EX-062 18 E

EX-02.12 PSEP 1B&2B to 35 HDR, EX-02.13 PSEP 1B&2B to 35 HDR:

Psep 2B to #35 FWHs Line is clad with Stainless Steel IP3-RPT-MULT-03162, Rev.

3; SFA EM 9321-F-20203 Sheet 1 Text19:

3-5EX-064 28 E

EX-02.15 FWH 35 HEADER:

Crossunder piping from Moisture Preseparators to 35A and 35B FWHs Line is clad with Stainless Steel IP3-RPT-MULT-03162, Rev.

3; SFA EM 9321-F-20203 Sheet 1 Text19:

3-5EX-065-A 18 E

EX-02.16 HDR 35 to FWH 35A:

Crossunder piping to Feedwater Heater 35A Line is clad with Stainless Steel IP3-RPT-MULT-03162, Rev.

3; SFA EM 9321-F-20203 Sheet 1 Text19:

3-5EX-066-A 18 E

EX-02.17 HDR 35 to FWH 35B:

Crossunder piping to Feedwater Heater 35B Line is clad with Stainless Steel IP3-RPT-MULT-03162, Rev.

3; SFA EM 9321-F-20203 Sheet 1 Text19:

3-5EX-067-A 18 E

EX-02.18 HDR 35 to FWH 35C:

Crossunder piping to Feedwater Heater 35C Line is clad with Stainless Steel IP3-RPT-MULT-03162, Rev.

3; SFA EM 9321-F-20203 Sheet 1 Text19:

3-5EX-068 1.5 E

Valve 5EX-5-1 bypass Valve shown closed on P&ID.

9321-F-20203 EI 9321-F-20203 Sheet 1 Text19:

3-5EX-069 1.5 E

Valve 5EX-5-2 bypass Valve shown closed on P&ID.

9321-F-20203 EI 9321-F-20203 Sheet 1 Text19:

3-5EX-070 1.5 E

Valve 5EX-5-3 bypass Valve shown closed on P&ID.

9321-F-20203 EI 9321-F-20203 Sheet 1 Text19:

3-5EX-071 1.5 E

Valve 5EX-5-1 bypass Valve shown closed on P&ID.

9321-F-20203 EI 9321-F-20203 Sheet 1 Report No. 0700.104-17, Appendix C, Revision 2 Page C-32 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Extraction Steam (EX), Unit 3 Section C: Excluded Lines 3-6EX-01: HP Turbine Extraction Steam to #36 Feedwater Heaters Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-6EX-001-B 12 E

EX-01.1 HP EXT to FWH 36 HDR:

HP Turbine Extraction Line to #36 FWHs.

This line is clad with Stainless Steel SFA Model EM 9321-F-20203 Sheet 1 Text19:

3-6EX-002-B 12 E

EX-01.2 HP EXT to FWH 36 HDR:

HP Turbine Extraction Line to #36 FWHs.

This line is clad with Stainless Steel SFA Model EM 9321-F-20203 Sheet 1 Text19:

3-6EX-003 18 E

EX-01.3 HP EXT FWH 36 HEADER:

HP Turbine Extraction Line to #36 FWHs.

This line is clad with Stainless Steel SFA Model EM 9321-F-20203 Sheet 1 Text19:

3-6EX-004 18 E

EX-01.4 HP EXT FWH 36 HEADER:

Extraction Steam header to FWH 36A and 36B This line is clad with Stainless Steel SFA Model EM 9321-F-20203 Sheet 1 Text19:

3-6EX-005 12 E

EX-01.5A HP EX HDR to FWH 36A:

Extraction Steam to FWH 36A Upstream of VCD tie-in.

This line is clad with Stainless Steel SFA Model EM 9321-F-20203 Sheet 1 Text19:

3-6EX-006 12 E

EX-01.5A HP EX HDR to FWH 36A:

Extraction Steam to FWH 36A Downstream of VCD tie-in.

This line is clad with Stainless Steel SFA Model EM 9321-F-20203 Sheet 1 Text19:

3-6EX-007 12 E

EX-01.5B HP EX HDR to FWH 36B:

Extraction Steam to FWH 36B Upstream of VCD tie-in.

This line is clad with Stainless Steel SFA Model EM 9321-F-20203 Sheet 1 Text19:

3-6EX-008 12 E

EX-01.5B HP EX HDR to FWH 36B:

Extraction Steam to FWH 36B Downstream of VCD tie-in.

This line is clad with Stainless Steel SFA Model EM 9321-F-20203 Sheet 1 Text19:

3-6EX-009 12 E

EX-01.5C HP EX HDR to FWH 36C:

Extraction Steam to FWH 36C Upstream of VCD tie-in.

This line is clad with Stainless Steel SFA Model EM 9321-F-20203 Sheet 1 Text19:

3-6EX-010 12 E

EX-01.5C HP EX HDR to FWH 36C:

Extraction Steam to FWH 36C Downstream of VCD tie-in.

This line is clad with Stainless Steel SFA Model EM 9321-F-20203 Sheet 1 Report No. 0700.104-17, Appendix C, Revision 2 Page C-33 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Extraction Steam (EX), Unit 3 Section C: Excluded Lines 3-6EX-01: HP Turbine Extraction Steam to #36 Feedwater Heaters Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-6EX-011 1

E 6EX-5-1 Bypass Line Valve shown closed on P&ID.

9321-F-20203 EI 9321-F-20203 Sheet 1 Text19:

3-6EX-012 1

E 6EX-5-2 Bypass Line Valve shown closed on P&ID.

9321-F-20203 EI 9321-F-20203 Sheet 1 Text19:

3-6EX-013 1

E 6EX-5-3 Bypass Line Valve shown closed on P&ID.

9321-F-20203 EI 9321-F-20203 Sheet 1 Text19:

3-6EX-014 1

E 6EX-1 Bypass Line Valve shown closed on P&ID.

9321-F-20203 EI 9321-F-20203 Sheet 1 Report No. 0700.104-17, Appendix C, Revision 2 Page C-34 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Feed Water (FW), Unit 3 Section A: CHECWORKS Model Lines 3-FW-01: Feedwater Lines from the Boiler Feed Pumps to the Steam Generators Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-FW-001 20 M

FW-01.1A BFP 31 to RCIRC T: BFP No. 31 Discharge Upstream of Recirc Line PEPSE 9321-F-20193 Text19:

3-FW-002 20 M

FW-01.2A BFP31 RCIRC T to HDR:

BFP No. 31 Discharge Downstream of Recirc Line PEPSE 9321-F-20193 Text19:

3-FW-003 20 M

FW-01.1B BFP 32 to RCIRC T: BFP No. 32 Discharge Upstream of Recirc Line PEPSE 9321-F-20193 Text19:

3-FW-004 20 M

FW-01.2B BFP32 RCIRC T to HDR:

BFP No. 32 Discharge Downstream of Recirc Line PEPSE 9321-F-20193 Text19:

3-FW-005 30 M

FW-01.3 BFP DISCHARGE HDR:

BFP Discharge Header to #36 FWHs Upstream of High Pr. FWH Bypass Line PEPSE 9321-F-20193 Text19:

3-FW-006 30 M

FW-01.3 BFP DISCHARGE HDR:

BFP Discharge Header to #36 FWHs Downstream of High Pr. FWH Bypass Line PEPSE 9321-F-20193 Text19:

3-FW-007 30 M

FW-01.4 BFP DISCHARGE HDR:

BFP Discharge Header to FWHs 36A and 36B PEPSE 9321-F-20193 Text19:

3-FW-008 18 M

FW-01.6A BFP HDR to FWH 36A:

Feedwater to FWH 36A PEPSE 9321-F-20193 Text19:

3-FW-009 18 M

FW-01.6B BFP HDR to FWH 36B:

Feedwater to FWH 36B PEPSE 9321-F-20193 Text19:

3-FW-010 18 M

FW-01.6C BFP HDR to FWH 36C:

Feedwater to FWH 36C PEPSE 9321-F-20193 Report No. 0700.104-17, Appendix C, Revision 2 Page C-35 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Feed Water (FW), Unit 3 Section A: CHECWORKS Model Lines 3-FW-01: Feedwater Lines from the Boiler Feed Pumps to the Steam Generators Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-FW-016 18 M

FW-02.1A FWH 36A to SG HDR:

Feedwater from FWH 36A PEPSE 9321-F-20193 Text19:

3-FW-017 18 M

FW-02.1B FWH 36B to SG HDR:

Feedwater from FWH 36B PEPSE 9321-F-20193 Text19:

3-FW-018 18 M

FW-02.1C FWH 36C to SG HDR:

Feedwater from FWH 36C PEPSE 9321-F-20193 Text19:

3-FW-019 30 M

FW-02.3 SG INLET HEADER:

Feedwater Header from FWH 36A and 36B PEPSE 9321-F-20193 Text19:

3-FW-020 30 M

FW-02.4 SG INLET HEADER: #36 FWH Feedwater Discharge Header Upstream of Bypass Line PEPSE 9321-F-20193 Text19:

3-FW-021 30 M

FW-02.4 SG INLET HEADER: #36 FWH Feedwater Discharge Header Downstream of Bypass Line PEPSE 9321-F-20193 Text19:

3-FW-023 18 M

FW-02.8A SG HDR to SG 31:

Feedwater to 31 Steam Generator PEPSE 9321-F-20193 Text19:

3-FW-025 18 M

FW-02.8B SG HDR to SG 32:

Feedwater to 32 Steam Generator PEPSE 9321-F-20193 Text19:

3-FW-027 18 M

FW-02.8D SG HDR to SG 33:

Feedwater to 33 Steam Generator PEPSE 9321-F-20193 Text19:

3-FW-029 18 M

FW-02.8C SG HDR to SG 34:

Feedwater to 34 Steam Generator PEPSE 9321-F-20193 Text19:

3-FW-031 30 M

FW-02.8D SG HDR to SG 33:

Feedwater Header to Steam Generators PEPSE 9321-F-20193 Text19:

3-FW-032 30 M

FW-02.8D SG HDR to SG 33:

Feedwater Header to Steam Generators PEPSE 9321-F-20193 Report No. 0700.104-17, Appendix C, Revision 2 Page C-36 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Feed Water (FW), Unit 3 Section A: CHECWORKS Model Lines 3-FW-01: Feedwater Lines from the Boiler Feed Pumps to the Steam Generators Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-FW-033 30 M

FW-02.6 SG INLET HEADER:

Feedwater Header to Steam Generators PEPSE 9321-F-20193 Text19:

3-FW-034 30 M

FW-02.6 SG INLET HEADER:

Feedwater Header to Steam Generators PEPSE 9321-F-20193 Text19:

3-FW-035 30 M

FW-02.5 SG INLET HEADER:

Feedwater Header to Steam Generators PEPSE 9321-F-20193 Text19:

3-FW-036 30 M

FW-02.5 SG INLET HEADER:

Feedwater Header to Steam Generators PEPSE 9321-F-20193 Text19:

3-FW-044-A 18 M

FW-02.8A SG HDR to SG 31:

Feedwater to 31 Steam Generator Upstream of BFD-6-1 PEPSE 9321-F-20193 Text19:

3-FW-044-B 18 M

FW-02.8A SG HDR to SG 31:

Feedwater to 31 Steam Generator Downstream of BFD-6-1 PEPSE 9321-F-20193 Text19:

3-FW-045-A 18 M

FW-02.8B SG HDR to SG 32:

Feedwater to 32 Steam Generator Upstream of BFD-6-2 PEPSE 9321-F-20193 Text19:

3-FW-045-B 18 M

FW-02.8B SG HDR to SG 32:

Feedwater to 32 Steam Generator Downstream of BFD-6-2 PEPSE 9321-F-20193 Text19:

3-FW-046-A 18 M

FW-02.8C SG HDR to SG 34:

Feedwater to 34 Steam Generator Upstream of BFD-6-4 PEPSE 9321-F-20193 Text19:

3-FW-046-B 18 M

FW-02.8C SG HDR to SG 34:

Feedwater to 34 Steam Generator Downstream of BFD-6-4 PEPSE 9321-F-20193 Report No. 0700.104-17, Appendix C, Revision 2 Page C-37 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Feed Water (FW), Unit 3 Section A: CHECWORKS Model Lines 3-FW-01: Feedwater Lines from the Boiler Feed Pumps to the Steam Generators Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-FW-047-A 18 M

FW-02.8D SG HDR to SG 33:

Feedwater to 33 Steam Generator Upstream of BFD-6-3 PEPSE 9321-F-20193 Text19:

3-FW-047-B 18 M

FW-02.8D SG HDR to SG 33:

Feedwater to 33 Steam Generator Downstream of BFD-6-3 PEPSE 9321-F-20193 Section B: SNM Program Lines 3-FW-01: Feedwater Lines from the Boiler Feed Pumps to the Steam Generators Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-FW-022 0.75 S

Feedwater to Sampling Upstream of BFD-1266-1 and 1266-2 Operating conditions unknown.

9321-F-20193 NS 9321-F-20193 Text19:

3-FW-024 6

S Feedwater FRV bypass line to 31 Steam Generator Operating conditions unknown.

9321-F-20193 NC 9321-F-20193 Text19:

3-FW-026 6

S Feedwater FRV bypass line to 32 Steam Generator Operating conditions unknown.

9321-F-20193 NC 9321-F-20193 Text19:

3-FW-028 6

S Feedwater FRV bypass line to 33 Steam Generator Operating conditions unknown.

9321-F-20193 NC 9321-F-20193 Text19:

3-FW-030 6

S Feedwater FRV bypass line to 34 Steam Generator Operating conditions unknown.

9321-F-20193 NC 9321-F-20193 Report No. 0700.104-17, Appendix C, Revision 2 Page C-38 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Feed Water (FW), Unit 3 Section C: Excluded Lines 3-FW-01: Feedwater Lines from the Boiler Feed Pumps to the Steam Generators Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-FW-011 1.5 E

BFD-3-1 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20193 Text19:

3-FW-012 1.5 E

BFD-3-2 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20193 Text19:

3-FW-013 1.5 E

BFD-3-3 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20193 Text19:

3-FW-014 18 E

High Pr. FWH Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20193 Text19:

3-FW-015 1.5 E

BFD-8 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20193 Text19:

3-FW-037 0.75 E

Drain from SG 33 Feedwater min-flow line.

Valve shown closed on P&ID.

P&ID EI 9321-F-20193 Text19:

3-FW-038 0.75 E

Drain from SG 34 Feedwater min-flow line.

Valve shown closed on P&ID.

P&ID EI 9321-F-20193 Text19:

3-FW-039 0.75 E

Drain from SG 32 Feedwater min-flow line.

Valve shown closed on P&ID.

P&ID EI 9321-F-20193 Text19:

3-FW-040 0.75 E

Drain from SG 11 Feedwater min-flow line.

Valve shown closed on P&ID.

P&ID EI 9321-F-20193 Text19:

3-FW-041 0.75 E

Drain from SG 33 & 34 Feedwater min-flow lines.

Valve shown closed on P&ID.

P&ID EI 9321-F-20193 Text19:

3-FW-042 0.75 E

Drain from SG 32, 33 & 34 Feedwater min-flow lines.

Valve shown closed on P&ID.

P&ID EI 9321-F-20193 Text19:

3-FW-043 0.75 E

Drain from Feedwater min-flow lines.

Valve shown closed on P&ID.

P&ID EI 9321-F-20193 3-FW-03: Boiler Feed Pump Recirc Lines to the Drains Collecting Tank Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-FW-048 6

E FW-04.1A BFP 31 RECIRC: BFP No. 31 Recirc to Drains Collecting Tank This line is CrMo.

SFA Database EM 9321-F-20193 Report No. 0700.104-17, Appendix C, Revision 2 Page C-39 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Feed Water (FW), Unit 3 Section C: Excluded Lines 3-FW-03: Boiler Feed Pump Recirc Lines to the Drains Collecting Tank Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-FW-049 6

E FW-04.1B BFP 32 RECIRC: BFP No. 32 Recirc to Drains Collecting Tank This line is CrMo.

SFA Database EM 9321-F-20193 Report No. 0700.104-17, Appendix C, Revision 2 Page C-40 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Gland Sealing Steam (GS), Unit 3 Section B: SNM Program Lines 3-GS-01: Gland Steam to and from HP, LP, and BFP Turbines Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-GS-001 6

S Gland Seal supply to BFP Turbines Flow Conditions Unknown PEPSE NC 9321-F-20243 Text19:

3-GS-005 4

S Steam to BFPT #32 Operating conditions unknown.

PEPSE NC 9321-F-20243 Text19:

3-GS-006 4

S Steam to BFPT #31 Operating conditions unknown.

PEPSE NC 9321-F-20243 Text19:

3-GS-007 3

S Steam to BFPT #32 Operating conditions unknown.

PEPSE NC 9321-F-20243 Text19:

3-GS-008 3

S Steam to BFPT #31 Operating conditions unknown.

PEPSE NC 9321-F-20243 Text19:

3-GS-017 3

S BFPT #32 Gland Steam Discharge Operating conditions unknown.

P&IDs NC 9321-F-20243 Text19:

3-GS-018 3

S BFPT #31 Gland Steam Discharge Operating conditions unknown.

P&IDs NC 9321-F-20243 Text19:

3-GS-021 6

S BFPT Gland Steam Discharge Header to Gland Condenser Operating conditions unknown.

P&IDs NC 9321-F-20243 Text19:

3-GS-022 2

S BFPT #31 Exhaust Cylinder Drain Operating conditions unknown.

P&ID NS 9321-F-20243 Text19:

3-GS-023 2

S BFPT #32 Exhaust Cylinder Drain Operating conditions unknown.

P&ID NS 9321-F-20243 Text19:

3-GS-024 3

S BFPT Exhaust Cylinder Drain header to Boiler Feed Pump Drip Tank Operating conditions unknown.

P&IDs NC 9321-F-20243 Text19:

3-GS-025 1

S BFPT Exhaust Cylinder Drain header line to Boiler Feed Pump Drip Tank vent Operating conditions unknown.

P&ID NS 9321-F-20243 Text19:

3-GS-026 3

S BFPT Drip Tank vent to Condenser

  1. 31 Operating conditions unknown.

P&ID NC 9321-F-20243 Text19:

3-GS-027 0.75 S

BFPT #32 Gland Steam Discharge Drain Operating conditions unknown.

P&ID NS 9321-F-20243 Text19:

3-GS-028 0.75 S

BFPT #31 Gland Steam Discharge Drain Operating conditions unknown.

P&ID NS 9321-F-20243 Text19:

3-GS-029 0.75 S

BFPT Gland Steam Discharge Header to Cylinder Drain Operating conditions unknown.

P&ID NS 9321-F-20243 Report No. 0700.104-17, Appendix C, Revision 2 Page C-41 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Gland Sealing Steam (GS), Unit 3 Section B: SNM Program Lines 3-GS-01: Gland Steam to and from HP, LP, and BFP Turbines Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-GS-030 12 S

Gland Seal Steam Header to HP and LP Turbines Operating conditions unknown.

P&ID NC B237144, 9321-05-FP-2355 Text19:

3-GS-031 10 S

Gland Seal to HP Turbine Operating conditions unknown.

P&ID NC 9321-05-FP-2355 Text19:

3-GS-032 10 S

Gland Seal to HP Turbine Operating conditions unknown.

P&ID NC 9321-05-FP-2355 Text19:

3-GS-033 6

S Gland Seal to LP Turbine 31 Operating conditions unknown.

P&ID NC 9321-05-FP-2355, 9321-F-20313 Text19:

3-GS-035 6

S Gland Seal to LP Turbine 31 Operating conditions unknown.

P&ID NC 9321-05-FP-2355, 9321-F-20313 Text19:

3-GS-037 6

S Gland Seal to LP Turbine 32 Operating conditions unknown.

P&ID NC 9321-05-FP-2355, 9321-F-20313 Text19:

3-GS-039 6

S Gland Seal to LP Turbine 32 Operating conditions unknown.

P&ID NC 9321-05-FP-2355, 9321-F-20313 Text19:

3-GS-041 6

S Gland Seal to LP Turbine 33 Operating conditions unknown.

P&ID NC 9321-05-FP-2355, 9321-F-20313 Text19:

3-GS-043 6

S Gland Seal to LP Turbine 33 Operating conditions unknown.

P&ID NC 9321-05-FP-2355, 9321-F-20313 Text19:

3-GS-045 6

S Gland Seal Return from HP Turbine Operating conditions unknown.

P&ID NC 9321-05-FP-2355, 9321-F-20313 Text19:

3-GS-046 6

S Gland Seal Return from HP Turbine Operating conditions unknown.

P&ID NC 9321-05-FP-2355, 9321-F-20313 Text19:

3-GS-047 S

Gland Seal Return from #31 LP Turbine Operating conditions unknown.

P&ID NC B237144 Text19:

3-GS-048 S

Gland Seal Return from #31 LP Turbine Operating conditions unknown.

P&ID NC B237144 Text19:

3-GS-049 S

Gland Seal Return from #32 LP Turbine Operating conditions unknown.

P&ID NC B237144 Report No. 0700.104-17, Appendix C, Revision 2 Page C-42 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Gland Sealing Steam (GS), Unit 3 Section B: SNM Program Lines 3-GS-01: Gland Steam to and from HP, LP, and BFP Turbines Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-GS-050 S

Gland Seal Return from #32 LP Turbine Operating conditions unknown.

P&ID NC B237144 Text19:

3-GS-051 S

Gland Seal Return from #33 LP Turbine Operating conditions unknown.

P&ID NC B237144 Text19:

3-GS-052 S

Gland Seal Return from #33 LP Turbine Operating conditions unknown.

P&ID NC B237144 Text19:

3-GS-053 S

Gland Seal return header to Gland Condenser Operating conditions unknown.

P&ID NC 9321-05-FP-2355, B237144 Text19:

3-GS-054 S

Gland Condenser Drain to Main Condenser Operating conditions unknown.

P&ID NC B237144 Text19:

3-GS-056 1

S Steam Discharge Header drain to waste header Operating conditions unknown.

P&ID NC B237144 Section C: Excluded Lines 3-GS-01: Gland Steam to and from HP, LP, and BFP Turbines Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-GS-019 0.75 E

BFPT #32 Gland Steam Floor Drain Low flow in waste drain P&ID EF 9321-F-20243 Text19:

3-GS-020 0.75 E

BFPT #31 Gland Steam Floor Drain Low flow in waste drain P&ID EF 9321-F-20243 Text19:

3-GS-034 2

E Gland Seal to floor drain Valve shown closed on P&ID.

P&ID EI 9321-F-20313 Text19:

3-GS-036 2

E Gland Seal to floor drain Valve shown closed on P&ID.

P&ID EI 9321-F-20313 Text19:

3-GS-038 2

E Gland Seal to floor drain Valve shown closed on P&ID.

P&ID EI 9321-F-20313 Text19:

3-GS-040 2

E Gland Seal to floor drain Valve shown closed on P&ID.

P&ID EI 9321-F-20313 Text19:

3-GS-042 2

E Gland Seal to floor drain Valve shown closed on P&ID.

P&ID EI 9321-F-20313 Report No. 0700.104-17, Appendix C, Revision 2 Page C-43 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Gland Sealing Steam (GS), Unit 3 Section C: Excluded Lines 3-GS-01: Gland Steam to and from HP, LP, and BFP Turbines Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-GS-044 2

E Gland Seal to drain collecting tank Valve shown closed on P&ID.

P&ID EI 9321-F-20313 Text19:

3-GS-055 E

Gland Condenser Waste Drain Valve normally closed.

Engineering Judgment EI B237144 Report No. 0700.104-17, Appendix C, Revision 2 Page C-44 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Gland Steam Traps (GST), Unit 3 Section B: SNM Program Lines 3-GST-01: Gland Steam to and from Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-GST-002 0.75 S

Steam to GST-1 Operating conditions unknown.

PEPSE NS 9321-F-20243 Text19:

3-GST-004 0.75 S

GST-1 Discharge to Header Operating conditions unknown.

PEPSE NS 9321-F-20243 Text19:

3-GST-009 0.75 S

Steam to GST-3 Operating conditions unknown.

PEPSE NS 9321-F-20243 Text19:

3-GST-011 0.75 S

GST-3 Discharge to Header Operating conditions unknown.

PEPSE NS 9321-F-20243 Text19:

3-GST-012 0.75 S

Steam to GST-2 Operating conditions unknown.

PEPSE NS 9321-F-20243 Text19:

3-GST-014 0.75 S

GST-2 Discharge to Header Operating conditions unknown.

PEPSE NC 9321-F-20243 Text19:

3-GST-015 2

S Header from GST-1 and 3 Operating conditions unknown.

PEPSE NC 9321-F-20243 Text19:

3-GST-016 2

S Gland Steam Trap Header to Boiler Feed Pump Drip Tank Operating conditions unknown.

PEPSE NC 9321-F-20243 Section C: Excluded Lines 3-GST-01: Gland Steam to and from Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-GST-003 0.75 E

GST-1 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-20243 Text19:

3-GST-010 0.75 E

GST-3 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-20243 Text19:

3-GST-013 0.75 E

GST-2 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-20243 Report No. 0700.104-17, Appendix C, Revision 2 Page C-45 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Heater Drains & Vents (HD), Unit 3 Section A: CHECWORKS Model Lines 3-1HD-01: #31 Feedwater Heater Drain Lines Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-1HD-001 12 M

FWH 31A to Condenser 33 via LCV 1124 Low temperature line with potential for flashing PEPSE 9321-F-20223 Sheet 2 Text19:

3-1HD-002 12 M

FWH 31B to Condenser 32 via LCV 1125 Low temperature line with potential for flashing PEPSE 9321-F-20223 Sheet 2 Text19:

3-1HD-003 12 M

FWH 31C to Condenser 31 via LCV 1126 Low temperature line with potential for flashing PEPSE 9321-F-20223 Sheet 2 3-2HD-01: #32 Feedwater Heater Drain Lines Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-2HD-001 12 M

HD-08.1A FWH 32A to FWH 31A:

FWH 32A Drain to FWH 31A Low temperature line with potential for flashing PEPSE 9321-F-20223 Sheet 2 Text19:

3-2HD-004 12 M

HD-08.1B FWH 32B to FWH 31B:

FWH 32B Drain to FWH 31B Low temperature line with potential for flashing PEPSE 9321-F-20223 Sheet 2 Text19:

3-2HD-007 12 M

HD-08.1C FWH 32C to FWH 31C:

FWH 32C Drain to FWH 31C Low temperature line with potential for flashing PEPSE 9321-F-20223 Sheet 2 3-3HD-01: #33 Feedwater Heater Drain Lines Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-3HD-001 8

M HD-06.1A FWH 33A to FWH 32A:

FWH 33A Drain to FWH 32A PEPSE 9321-F-20223 Sheet 2 Text19:

3-3HD-002 8

M HD-06.1B FWH 33B to FWH 32B:

FWH 33B Drain to FWH 32B PEPSE 9321-F-20223 Sheet 2 Text19:

3-3HD-003 8

M HD-06.1C FWH 33C to FWH 32C:

FWH 33C Drain to FWH 32C PEPSE 9321-F-20223 Sheet 2 Report No. 0700.104-17, Appendix C, Revision 2 Page C-46 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Heater Drains & Vents (HD), Unit 3 Section A: CHECWORKS Model Lines 3-4HD-01: #34 Feedwater Heater Drain Lines Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-4HD-001 6

M HD-04.1A FWH 34A to FWH 33A:

FWH 34A Drain to FWH 33A PEPSE 9321-F-20223 Sheet 2 Text19:

3-4HD-002 6

M HD-04.1B FWH 34B to FWH 33B:

FWH 34B Drain to FWH 33B PEPSE 9321-F-20223 Sheet 2 Text19:

3-4HD-003 6

M HD-04.1C FWH 34C to FWH 33C:

FWH 34C Drain to FWH 33C PEPSE 9321-F-20223 Sheet 2 3-5HD-01: Heater Drains from #35 Feedwater Heaters Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-5HD-001 10 M

HD-03.1A FWH 35A to HD TK: FWH 35A Drain to Heater Drain Tank PEPSE 9321-F-20223 Sheet 1 Text19:

3-5HD-002 10 M

HD-03.1B FWH 35B to HD TK: FWH 35B Drain to Heater Drain Tank PEPSE 9321-F-20223 Sheet 1 Text19:

3-5HD-003 10 M

HD-03.1C FWH 35C to HD TK: FWH 35C Drain to Heater Drain Tank PEPSE 9321-F-20223 Sheet 1 3-5HD-03: HDT Drains to Heater Drain Pumps and Condensers and Heater Drain Pump Vents to HDT Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-5HD-019 18 M

HD-10.1A HD TK to HD PMP 31:

HDT to #31 HDP PEPSE 9321-F-20223 Sheet 1 Text19:

3-5HD-020 18 M

HD-10.1B HD TK to HD PMP 32:

HDT to #32 HDP PEPSE 9321-F-20223 Sheet 1 Report No. 0700.104-17, Appendix C, Revision 2 Page C-47 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Heater Drains & Vents (HD), Unit 3 Section A: CHECWORKS Model Lines 3-6HD-01: Heater Drains from #36 Feedwater Heaters Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-6HD-001 10 M

HD-01.1A FWH 36A to HD TK: Drain from Feedwater Heater 36A to Heater Drain Tank PEPSE 9321-F-20223 Sheet 1 Text19:

3-6HD-002 10 M

HD-01.1B FWH 36B to HD TK: Drain from Feedwater Heater 36B to Heater Drain Tank PEPSE 9321-F-20223 Sheet 1 Text19:

3-6HD-003 10 M

HD-01.1C FWH 36C to HD TK:

Drain from Feedwater Heater 36C to Heater Drain Tank PEPSE 9321-F-20223 Sheet 1 3-HD-01: Heater Drain Pump discharge to Boiler Feed Pumps Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-HD-001 12 M

HD-11.1A HD PMP 31 to HDR: #31 HDP to Heater Drain Pump Header PEPSE 9321-F-20223 Sheet 1 Text19:

3-HD-002 12 M

HD-11.1B HD PMP 32 to HDR: #32 HDP to Heater Drain Pump Header PEPSE 9321-F-20223 Sheet 1 Text19:

3-HD-003 16 M

HD-12.2A HD PMP HDR to CD SYS:

Heater Drain Pump Header to Boiler Feed Pumps PEPSE 9321-F-20223 Sheet 1, 9321-F-20183 Sheet 2 Text19:

3-HD-004 16 M

HD-12.2A HD PMP HDR to CD SYS:

Heater Drain Pump Discharge to BFPs PEPSE 9321-F-20183 Sheet 2 Report No. 0700.104-17, Appendix C, Revision 2 Page C-48 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Heater Drains & Vents (HD), Unit 3 Section B: SNM Program Lines 3-1HD-02: #31 Feedwater Heater Vents Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-1HD-010 5

S FWH 31A 5" Vent to Condenser 33 Operating conditions unknown.

P&ID NC 9321-F-20223 Sheet 2 Text19:

3-1HD-011 5

S FWH 31B 5" Vent to Condenser 32 Operating conditions unknown.

P&ID NC 9321-F-20223 Sheet 2 Text19:

3-1HD-012 5

S FWH 31C 5" Vent to Condenser 31 Operating conditions unknown.

P&ID NC 9321-F-20223 Sheet 2 Text19:

3-1HD-013 1

S FWH 31A 1" Vent to Condenser 33 Operating conditions unknown.

P&ID NS 9321-F-20223 Sheet 2 Text19:

3-1HD-014 1

S FWH 31B 1" Vent to Condenser 32 Operating conditions unknown.

P&ID NS 9321-F-20223 Sheet 2 Text19:

3-1HD-015 1

S FWH 31C 1" Vent to Condenser 31 Operating conditions unknown.

P&ID NS 9321-F-20223 Sheet 2 3-2HD-02: #32 Feedwater Heater Vents Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-2HD-013 2.5 S

FWH 32A 2-1/2" Vent to Condenser 33 Operating conditions unknown.

P&ID NC 9321-F-20223 Sheet 2 Text19:

3-2HD-014 2.5 S

FWH 32B 2-1/2" Vent to Condenser 32 Operating conditions unknown.

P&ID NC 9321-F-20223 Sheet 2 Text19:

3-2HD-015 2.5 S

FWH 32C 2-1/2" Vent to Condenser 31 Operating conditions unknown.

P&ID NC 9321-F-20223 Sheet 2 Text19:

3-2HD-016 1

S FWH 32A 1" Vent to Condenser 33 Operating conditions unknown.

P&ID NS 9321-F-20223 Sheet 2 Text19:

3-2HD-017 1

S FWH 32B 1" Vent to Condenser 32 Operating conditions unknown.

P&ID NS 9321-F-20223 Sheet 2 Text19:

3-2HD-018 1

S FWH 32C 1" Vent to Condenser 31 Operating conditions unknown.

P&ID NS 9321-F-20223 Sheet 2 Text19:

3-2HD-019 6

S FWH 32A High Level Dump to Condenser 33 Operating conditions unknown.

P&ID NC 9321-F-20223 Sheet 2 Text19:

3-2HD-020 6

S FWH 32B High Level Dump to Condenser 32 Operating conditions unknown.

P&ID NC 9321-F-20223 Sheet 2 Text19:

3-2HD-021 6

S FWH 32C High Level Dump to Condenser 31 Operating conditions unknown.

P&ID NC 9321-F-20223 Sheet 2 Report No. 0700.104-17, Appendix C, Revision 2 Page C-49 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Heater Drains & Vents (HD), Unit 3 Section B: SNM Program Lines 3-3HD-01: #33 Feedwater Heater Drain Lines Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-3HD-007 8

S FWH 33A drain condenser bypass line to FWH 32 A Flow Conditions Unknown PEPSE NC 9321-F-20223 Sheet 2 Text19:

3-3HD-010 8

S FWH 33A Drain to Condenser 33 Flow Conditions Unknown PEPSE NC 9321-F-20223 Sheet 2 3-4HD-02: #34 Feedwater Heater Vents Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-4HD-015 1

S FWH 34A 1" Vent Operating conditions unknown.

P&ID NS 9321-F-20223 Sheet 2 Text19:

3-4HD-016 1

S FWH 34B 1" Vent Operating conditions unknown.

P&ID NS 9321-F-20223 Sheet 2 Text19:

3-4HD-017 1

S FWH 34C 1" Vent Operating conditions unknown.

P&ID NS 9321-F-20223 Sheet 2 Text19:

3-4HD-018 2

S 2" Vent Header from FWH 34A and 34B Operating conditions unknown.

P&ID NS 9321-F-20223 Sheet 2 Text19:

3-4HD-019 2

S 2" Vent Header from #34 FWHs to Condenser 32 Operating conditions unknown.

P&ID NS 9321-F-20223 Sheet 2 Text19:

3-4HD-020 1.5 S

FWH 34A 1.5" Vent Operating conditions unknown.

P&ID NS 9321-F-20223 Sheet 2 Text19:

3-4HD-021 1.5 S

FWH 34B 1.5" Vent Operating conditions unknown.

P&ID NS 9321-F-20223 Sheet 2 Text19:

3-4HD-022 1.5 S

FWH 34C 1.5" Vent Operating conditions unknown.

P&ID NS 9321-F-20223 Sheet 2 Text19:

3-4HD-023 2

S 2" Vent Header from FWH 34A and 34B Operating conditions unknown.

P&ID NS 9321-F-20223 Sheet 2 Text19:

3-4HD-024 3

S 3" Vent Header from #34 FWHs to Condenser 32 Operating conditions unknown.

P&ID NC 9321-F-20223 Sheet 2 Report No. 0700.104-17, Appendix C, Revision 2 Page C-50 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Heater Drains & Vents (HD), Unit 3 Section B: SNM Program Lines 3-5HD-02: Heater Vents from #35 Feedwater Heater and Heater Drain Tank vents to #35 Feedwater Heaters and Flas Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-5HD-004 10 S

Heater Drain Tank vent to FWH 35A Operating conditions unknown.

PEPSE NC 9321-F-20223 Sheet 1 Text19:

3-5HD-005 10 S

Heater Drain Tank vent to FWH 35B Operating conditions unknown.

PEPSE NC 9321-F-20223 Sheet 1 Text19:

3-5HD-006 10 S

Heater Drain Tank vent to FWH 35C Operating conditions unknown.

PEPSE NC 9321-F-20223 Sheet 1 Text19:

3-5HD-007 12 S

Heater Drain Tank vent to Flash Tank Operating conditions unknown.

PEPSE NC 9321-F-20223 Sheet 1 Text19:

3-5HD-008 12 S

Heater Drain Tank vent to Flash Tank Operating conditions unknown.

PEPSE NC 9321-F-20223 Sheet 1 Text19:

3-5HD-009 1.25 S

FWH 35A Vent header to condenser No. 33 Operating conditions unknown.

PEPSE NC 9321-F-20223 Sheet 1 Text19:

3-5HD-010 1.25 S

FWH 35B Vent header to condenser No. 33 Operating conditions unknown.

PEPSE NC 9321-F-20223 Sheet 1 Text19:

3-5HD-011 1.25 S

FWH 35C Vent header to condenser No. 33 Operating conditions unknown.

PEPSE NC 9321-F-20223 Sheet 1 Text19:

3-5HD-012 2

S Vent line from 35A and 35B Feedwater Heaters to condenser Operating conditions unknown.

PEPSE NC 9321-F-20223 Sheet 1 Text19:

3-5HD-013 2.5 S

Vent from #35 Feedwater Heaters to Condenser No.33 Operating conditions unknown.

PEPSE NC 9321-F-20223 Sheet 1, 9321-F-20223 Sheet 2 Text19:

3-5HD-014 6

S FWH 35A vent header to Flash Tank Operating conditions unknown.

PEPSE NC 9321-F-20223 Sheet 1 Text19:

3-5HD-015 6

S FWH 35B vent header to Flash Tank Operating conditions unknown.

PEPSE NC 9321-F-20223 Sheet 1 Text19:

3-5HD-016 6

S FWH 35C vent header to Flash Tank Operating conditions unknown.

PEPSE NC 9321-F-20223 Sheet 1 Text19:

3-5HD-017 10 S

FWH 35B and 35C to Flash Tank Operating conditions unknown.

PEPSE NC 9321-F-20223 Sheet 1 Text19:

3-5HD-018 10 S

Vent from #35 Feedwater Heaters to Flash Tank Operating conditions unknown.

PEPSE NC 9321-F-20223 Sheet 1 Report No. 0700.104-17, Appendix C, Revision 2 Page C-51 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Heater Drains & Vents (HD), Unit 3 Section B: SNM Program Lines 3-5HD-03: HDT Drains to Heater Drain Pumps and Condensers and Heater Drain Pump Vents to HDT Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-5HD-021 2

S

  1. 31 HDP vent to HDT Operating conditions unknown.

P&ID NS 9321-F-20223 Sheet 1 Text19:

3-5HD-022 2

S

  1. 32 HDP vent to HDT Operating conditions unknown.

P&ID NS 9321-F-20223 Sheet 1 3-6HD-02: Heater Vents from #36 Feedwater Heater Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-6HD-020 12 S

FWH 36A vent to Flash Tank Operating conditions unknown.

PEPSE NC 9321-F-20223 Sheet 1 Text19:

3-6HD-021 12 S

FWH 36A vent to Flash Tank Operating conditions unknown.

PEPSE NC 9321-F-20223 Sheet 1 Text19:

3-6HD-022 12 S

FWH 36B vent to Flash Tank Operating conditions unknown.

PEPSE NC 9321-F-20223 Sheet 1 Text19:

3-6HD-023 12 S

FWH 36B vent to Flash Tank Operating conditions unknown.

PEPSE NC 9321-F-20223 Sheet 1 Text19:

3-6HD-024 12 S

FWH 36C vent to Flash Tank Operating conditions unknown.

PEPSE NC 9321-F-20223 Sheet 1 Text19:

3-6HD-025 12 S

FWH 36C vent to Flash Tank Operating conditions unknown.

PEPSE NC 9321-F-20223 Sheet 1 Text19:

3-6HD-028 16 S

Flash Tank drain to Discharge Tunnel Operating conditions unknown.

PEPSE NC 9321-F-20223 Sheet 1 Section C: Excluded Lines 3-1HD-01: #31 Feedwater Heater Drain Lines Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-1HD-004 12 E

FWH 31A to Condenser 33 via LCV 1124A Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Text19:

3-1HD-005 12 E

FWH 31B to Condenser 32 via LCV 1125A Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Text19:

3-1HD-006 12 E

FWH 31C to Condenser 31 via LCV 1126A Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Report No. 0700.104-17, Appendix C, Revision 2 Page C-52 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Heater Drains & Vents (HD), Unit 3 Section C: Excluded Lines 3-1HD-02: #31 Feedwater Heater Vents Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-1HD-007 6

E FWH 31A High Level Dump to Condenser 33 High level dumps operate infrequently P&ID EI 9321-F-20223 Sheet 2 Text19:

3-1HD-008 6

E FWH 31B High Level Dump to Condenser 32 High level dumps operate infrequently P&ID EI 9321-F-20223 Sheet 2 Text19:

3-1HD-009 6

E FWH 31C High Level Dump to Condenser 31 High level dumps operate infrequently P&ID EI 9321-F-20223 Sheet 2 3-2HD-01: #32 Feedwater Heater Drain Lines Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-2HD-002 12 E

HD-09.3A FWH 32A to FWH 31A:

FWH 32A Drain to FWH 31A Line replaced with Stainless Steel SFA Model EM 9321-F-20223 Sheet 2 Text19:

3-2HD-003 12 E

HD-09.4A FWH 32A to FWH 31A:

FWH 32A Drain to FWH 31A Line replaced with Stainless Steel SFA Model EM 9321-F-20223 Sheet 2 Text19:

3-2HD-005 12 E

HD-09.3B FWH 32B to FWH 31B:

FWH 32B Drain to FWH 31B Line replaced with Stainless Steel SFA Model EM 9321-F-20223 Sheet 2 Text19:

3-2HD-006 12 E

HD-09.4B FWH 32B to FWH 31B:

FWH 32B Drain to FWH 31B Line replaced with Stainless Steel SFA Model EM 9321-F-20223 Sheet 2 Text19:

3-2HD-008 12 E

HD-09.3C FWH 32C to FWH 31C:

FWH 32C Drain to FWH 31C Line replaced with Stainless Steel SFA Model EM 9321-F-20223 Sheet 2 Text19:

3-2HD-009 12 E

HD-09.4C FWH 32C to FWH 31C:

FWH 32C Drain to FWH 31C Line replaced with Stainless Steel SFA Model EM 9321-F-20223 Sheet 2 Text19:

3-2HD-010 8

E FWH 32A Drain to Condenser 33 Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Text19:

3-2HD-011 8

E FWH 32B Drain to Condenser 32 Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Text19:

3-2HD-012 8

E FWH 32C Drain to Condenser 31 Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Report No. 0700.104-17, Appendix C, Revision 2 Page C-53 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Heater Drains & Vents (HD), Unit 3 Section C: Excluded Lines 3-3HD-01: #33 Feedwater Heater Drain Lines Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-3HD-004 8

E FWH 33A Drain to Condenser 33 Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Text19:

3-3HD-005 8

E FWH 33B Drain to Condenser 32 Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Text19:

3-3HD-006 8

E FWH 33C Drain to Condenser 31 Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Text19:

3-3HD-008 8

E FWH 33B Condenser 32 bypass to FWH 32B Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Text19:

3-3HD-009 8

E FWH 33C Condenser 31 bypass to FWH 32C Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Text19:

3-3HD-011 8

E FWH 33B Drain to Condenser 32 Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Text19:

3-3HD-012 8

E FWH 33C Drain to Condenser 31 Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 3-3HD-02: #33 Feedwater Heater Vents Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-3HD-013 1

E FWH 33A 1" Vent Replaced with Chrome-moly IP3-RPT-MULT-03162 EM 9321-F-20223 Sheet 2 Text19:

3-3HD-014 1

E FWH 33B 1" Vent Replaced with Chrome-moly IP3-RPT-MULT-03162 EM 9321-F-20223 Sheet 2 Text19:

3-3HD-015 1

E FWH 33C 1" Vent Replaced with Chrome-moly IP3-RPT-MULT-03162 EM 9321-F-20223 Sheet 2 Text19:

3-3HD-016 1.5 E

1.5" Vent From FWH 33A and 33B Replaced with Chrome-moly IP3-RPT-MULT-03162 EM 9321-F-20223 Sheet 2 Text19:

3-3HD-017 2

E 2" Vent From #33 FWHs to Condenser #31 Replaced with Chrome-moly IP3-RPT-MULT-03162 EM 9321-F-20223 Sheet 2 Text19:

3-3HD-018 2

E 2" Vent from FWH 33A Line replaced with Chrome-Moly in 3R12.

IP3-RPT-MULT-03162, Rev.

3, Appendix B EM 9321-F-20223 Sheet 2 Text19:

3-3HD-019 2

E 2" Vent from FWH 33B Line replaced with Chrome-Moly in 3R12.

IP3-RPT-MULT-03162, Rev.

3, Appendix B EM 9321-F-20223 Sheet 2 Text19:

3-3HD-020 2

E 2" Vent from FWH 33C Line replaced with Chrome-Moly in 3R12.

IP3-RPT-MULT-03162, Rev.

3, Appendix B EM 9321-F-20223 Sheet 2 Report No. 0700.104-17, Appendix C, Revision 2 Page C-54 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Heater Drains & Vents (HD), Unit 3 Section C: Excluded Lines 3-3HD-02: #33 Feedwater Heater Vents Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-3HD-021 2

E 2" Vent through orifice 3HD-RO-39-1 Line replaced with Chrome-Moly in 3R12.

IP3-RPT-MULT-03162, Rev.

3, Appendix B EM 9321-F-20223 Sheet 2 Text19:

3-3HD-022 2

E 2" Vent through orifice 3HD-RO-39-2 Line replaced with Chrome-Moly in 3R12.

IP3-RPT-MULT-03162, Rev.

3, Appendix B EM 9321-F-20223 Sheet 2 Text19:

3-3HD-023 2

E 2" Vent through orifice 3HD-RO-39-3 Line replaced with Chrome-Moly in 3R12.

IP3-RPT-MULT-03162, Rev.

3, Appendix B EM 9321-F-20223 Sheet 2 Text19:

3-3HD-024 2

E 2" Vent orifice 3HD-RO-39-1 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Text19:

3-3HD-025 2

E 2" Vent orifice 3HD-RO-39-2 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Text19:

3-3HD-026 2

E 2" Vent orifice 3HD-RO-39-3 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Text19:

3-3HD-027 2

E FWH 33A 2" Vent Header Line replaced with Chrome-Moly in 3R12.

IP3-RPT-MULT-03162, Rev.

3, Appendix B EM 9321-F-20223 Sheet 2 Text19:

3-3HD-028 2

E FWH 33B 2" Vent Header Line replaced with Chrome-Moly in 3R12.

IP3-RPT-MULT-03162, Rev.

3, Appendix B EM 9321-F-20223 Sheet 2 Text19:

3-3HD-029 2

E FWH 33C 2" Vent Header Line replaced with Chrome-Moly in 3R12.

IP3-RPT-MULT-03162, Rev.

3, Appendix B EM 9321-F-20223 Sheet 2 Text19:

3-3HD-030 3

E 3" Vent Header from FWH 33A and 33B Line replaced with Chrome-Moly in 3R12.

IP3-RPT-MULT-03162, Rev.

3, Appendix B EM 9321-F-20223 Sheet 2 Text19:

3-3HD-031 4

E 4" Vent Header from #33 FWHs Line replaced with Chrome-Moly in 3R12.

IP3-RPT-MULT-03162, Rev.

3, Appendix B EM 9321-F-20223 Sheet 2 Text19:

3-3HD-032 8

E FWH 33A Relief Valve Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Text19:

3-3HD-033 8

E FWH 33B Relief Valve Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Text19:

3-3HD-034 8

E FWH 33C Relief Valve Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Text19:

3-3HD-035 12 E

Relief Valve Header from FWH 33C and 33B Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Report No. 0700.104-17, Appendix C, Revision 2 Page C-55 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Heater Drains & Vents (HD), Unit 3 Section C: Excluded Lines 3-3HD-02: #33 Feedwater Heater Vents Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-3HD-036 12 E

  1. 33 FWH Relief Valve vent to Discharge Tunnel Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 3-4HD-01: #34 Feedwater Heater Drain Lines Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-4HD-004 6

E FWH 34A drain bypass to condenser Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Text19:

3-4HD-005 6

E FWH 34B drain bypass to condenser Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Text19:

3-4HD-006 6

E FWH 34C drain bypass to condenser Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Text19:

3-4HD-007 6

E FWH 34A drain to condenser #33 Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Text19:

3-4HD-008 6

E FWH 34B drain to condenser #32 Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Text19:

3-4HD-009 6

E FWH 34C drain to condenser #31 Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 3-4HD-02: #34 Feedwater Heater Vents Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-4HD-010 8

E FWH 34A Relief Valve Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Text19:

3-4HD-011 8

E FWH 34B Relief Valve Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Text19:

3-4HD-012 8

E FWH 34C Relief Valve Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Text19:

3-4HD-013 12 E

Relief Valve Header from FWH 34C and 34B Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Text19:

3-4HD-014 12 E

  1. 34 FWH Relief Valve vent to Discharge Tunnel Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 2 Report No. 0700.104-17, Appendix C, Revision 2 Page C-56 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Heater Drains & Vents (HD), Unit 3 Section C: Excluded Lines 3-5HD-03: HDT Drains to Heater Drain Pumps and Condensers and Heater Drain Pump Vents to HDT Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-5HD-023 24 E

Heater Drain Tank drain to Condensers Line operates less than 2% of the time P&ID EI 9321-F-20223 Sheet 1, 9321-F-20223 Sheet 2 Text19:

3-5HD-024 24 E

HDT Drain Header to Condensers 31 and 32 Line operates less than 2% of the time P&ID EI 9321-F-20223 Sheet 2 Text19:

3-5HD-025-A 14 E

HDT Drain to LCV-1127D Line operates less than 2% of the time. It has been noted that LCV 1127D leaks P&ID EI 9321-F-20223 Sheet 2 Text19:

3-5HD-025-B 14 E

LCV-1127D to Condenser 31 Line operates less than 2% of the time. It has been noted that LCV 1127D leaks P&ID EI 9321-F-20223 Sheet 2 Text19:

3-5HD-026 8

E LCV-1127D Bypass Line Line operates less than 2% of the time P&ID EI 9321-F-20223 Sheet 2 Text19:

3-5HD-027-A 14 E

HDT Drain to LCV-1127C Line operates less than 2% of the time P&ID EI 9321-F-20223 Sheet 2 Text19:

3-5HD-027-B 14 E

LCV-1127C to Condenser 32 Line operates less than 2% of the time P&ID EI 9321-F-20223 Sheet 2 Text19:

3-5HD-028 8

E LCV-1127C Bypass Line Line operates less than 2% of the time P&ID EI 9321-F-20223 Sheet 2 Text19:

3-5HD-029-A 14 E

HDT Drain to LCV-1127B Line operates less than 2% of the time P&ID EI 9321-F-20223 Sheet 2 Text19:

3-5HD-029-B 14 E

LCV-1127B to Condenser 33 Line operates less than 2% of the time P&ID EI 9321-F-20223 Sheet 2 Text19:

3-5HD-030 8

E LCV-1127B Bypass Line Line operates less than 2% of the time P&ID EI 9321-F-20223 Sheet 2 Text19:

3-5HD-031 2

E Fill Line from HDT Drain to Condensers to Moisture Preseparator drain Line operates less than 2% of the time P&ID EI 9321-F-20223 Sheet 2, 9321-F-20223 Sheet 1 3-6HD-01: Heater Drains from #36 Feedwater Heaters Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-6HD-004 1

E Drain header from Feedwater 36A to Condenser Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 1 Text19:

3-6HD-005 1.25 E

Drain header from Feedwater 36A to Condenser Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 1 Report No. 0700.104-17, Appendix C, Revision 2 Page C-57 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Heater Drains & Vents (HD), Unit 3 Section C: Excluded Lines 3-6HD-01: Heater Drains from #36 Feedwater Heaters Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-6HD-006 1.25 E

Drain header from Feedwater 36A to Condenser Line replaced with Chrome-Moly in 3R11.

IP3-RPT-MULT-03162, Rev.

3, Attachment B EM 9321-F-20223 Sheet 1 Text19:

3-6HD-007 1.25 E

Bypass of valves 6HD-28-1 and 6HD-30-1 Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 1 Text19:

3-6HD-008 1.25 E

Drain from Feedwater Heater 36A towards Condenser Line replaced with Chrome-Moly in 3R11.

IP3-RPT-MULT-03162, Rev.

3, Attachment B EM 9321-F-20223 Sheet 1 Text19:

3-6HD-009 1

E Drain header from Feedwater 36B to Condenser Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 1 Text19:

3-6HD-010 1.25 E

Drain header from Feedwater 36B to Condenser Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 1 Text19:

3-6HD-011 1.25 E

Drain header from Feedwater 36B to Condenser Line replaced with Chrome-Moly in 3R11.

IP3-RPT-MULT-03162, Rev.

3, Attachment B EM 9321-F-20223 Sheet 1 Text19:

3-6HD-012 1.25 E

Bypass of valves 6HD-28-2 and 6HD-30-2 Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 1 Text19:

3-6HD-013 2

E Drain from Feedwater Heaters 36A and 36B to Condenser Line replaced with Chrome-Moly in 3R11.

IP3-RPT-MULT-03162, Rev.

3, Attachment B EM 9321-F-20223 Sheet 1 Text19:

3-6HD-014 1

E Drain header from Feedwater 36C to Condenser Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 1 Text19:

3-6HD-015 1.25 E

Drain header from Feedwater 36C to Condenser Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 1 Text19:

3-6HD-016 1.25 E

Drain header from Feedwater 36C to Condenser Line replaced with Chrome-Moly in 3R11.

IP3-RPT-MULT-03162, Rev.

3, Attachment B EM 9321-F-20223 Sheet 1 Text19:

3-6HD-017 1.25 E

Bypass of valves 6HD-28-3 and 6HD-30-3 Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 1 Text19:

3-6HD-018 1.25 E

Drain header from Feedwater 36C to Condenser Line replaced with Chrome-Moly in 3R11.

IP3-RPT-MULT-03162, Rev.

3, Attachment B EM 9321-F-20223 Sheet 1 Text19:

3-6HD-019 2.5 E

Drain from #36 Feedwater heaters to No 33 Condenser Line replaced with Chrome-Moly in 3R11.

IP3-RPT-MULT-03162, Rev.

3, Attachment B EM 9321-F-20223 Sheet 1, 9321-F-20223 Sheet 2 Report No. 0700.104-17, Appendix C, Revision 2 Page C-58 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Heater Drains & Vents (HD), Unit 3 Section C: Excluded Lines 3-6HD-02: Heater Vents from #36 Feedwater Heater Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-6HD-029 E

Flash Tank vent to atmosphere Low to no flow in vent to atmosphere PEPSE EF 9321-F-20223 Sheet 1 Text19:

3-6HD-030 E

Flash Tank vent to atmosphere Low to no flow in vent to atmosphere PEPSE EF 9321-F-20223 Sheet 1 Report No. 0700.104-17, Appendix C, Revision 2 Page C-59 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Steam (MS), Unit 3 Section A: CHECWORKS Model Lines 3-MS-10: HP Turbine Crossunder Piping to MSRs and condensers Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-MS-183 32 M

HP Turbine Crossunder to Moisture Preseparator 1A PEPSE 9321-F-20203 Sheet 1 Text19:

3-MS-184 32 M

HP Turbine Crossunder to Moisture Preseparator 1B PEPSE 9321-F-20203 Sheet 1 Text19:

3-MS-185 32 M

HP Turbine Crossunder to Moisture Preseparator 2A PEPSE 9321-F-20203 Sheet 1 Text19:

3-MS-186 32 M

HP Turbine Crossunder to Moisture Preseparator 2B PEPSE 9321-F-20203 Sheet 1 Text19:

3-MS-187 32 M

Moisture Preseparator 1A to MSR Header PEPSE 9321-F-20203 Sheet 1 Text19:

3-MS-188 32 M

Moisture Preseparator 1B to MSR Header PEPSE 9321-F-20203 Sheet 1 Text19:

3-MS-189 32 M

Moisture Preseparator 2A to MSR Header PEPSE 9321-F-20203 Sheet 1 Text19:

3-MS-190 32 M

Moisture Preseparator 2B to MSR Header PEPSE 9321-F-20203 Sheet 1 Text19:

3-MS-191 45.5 M

Moisture Preseparator Header to A MSRs PEPSE 9321-F-20203 Sheet 1 Text19:

3-MS-192 45.5 M

Moisture Preseparator Header to B MSRs PEPSE 9321-F-20203 Sheet 1 Text19:

3-MS-193 37 M

Moisture Preseparator Header to MSR 31A and 32A PEPSE 9321-F-20203 Sheet 1 Text19:

3-MS-194 37 M

Moisture Preseparator Header to MSR 31B and 32B PEPSE 9321-F-20203 Sheet 1 Text19:

3-MS-195 26.5 M

Moisture Preseparator Header to MSR 31A PEPSE 9321-F-20203 Sheet 1 Text19:

3-MS-196 26.5 M

Moisture Preseparator Header to MSR 32A PEPSE 9321-F-20203 Sheet 1 Report No. 0700.104-17, Appendix C, Revision 2 Page C-60 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Steam (MS), Unit 3 Section A: CHECWORKS Model Lines 3-MS-10: HP Turbine Crossunder Piping to MSRs and condensers Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-MS-197 26.5 M

Moisture Preseparator Header to MSR 33A PEPSE 9321-F-20203 Sheet 1 Text19:

3-MS-198 26.5 M

Moisture Preseparator Header to MSR 31B PEPSE 9321-F-20203 Sheet 1 Text19:

3-MS-199 26.5 M

Moisture Preseparator Header to MSR 32B PEPSE 9321-F-20203 Sheet 1 Text19:

3-MS-200 26.5 M

Moisture Preseparator Header to MSR 33B PEPSE 9321-F-20203 Sheet 1 Section B: SNM Program Lines 3-MS-01: Main Steam from SG to HP Turbine, BFP Turbine, MSRs, Aux. Steam, SJAEs, and Priming Ejectors.

Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-MS-005 28 S

Main Steam from Steam Generator 31 Shell High quality main steam line.

PEPSE NQ 9321-F-20173, 9321-F-20173 Text19:

3-MS-006 28 S

Main Steam from Steam Generator 32 Shell High quality main steam line.

PEPSE NQ 9321-F-20173, 9321-F-20173 Text19:

3-MS-007 28 S

Main Steam from Steam Generator 33 Shell High quality main steam line.

PEPSE NQ 9321-F-20173, 9321-F-20173 Text19:

3-MS-008 28 S

Main Steam from Steam Generator 34 Shell High quality main steam line.

PEPSE NQ 9321-F-20173, 9321-F-20173 Text19:

3-MS-009 24 S

Line from 3-MS-005 to Seal Steam and MSR Header.

High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-010 24 S

Line from 3-MS-006 to Gland Seal Steam and MSR B Header.

High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-011 20 S

Gland Seal Steam, MSR B, and Aux.

Steam Header.

High quality main steam line.

PEPSE NQ 9321-F-20173 Report No. 0700.104-17, Appendix C, Revision 2 Page C-61 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Steam (MS), Unit 3 Section B: SNM Program Lines 3-MS-01: Main Steam from SG to HP Turbine, BFP Turbine, MSRs, Aux. Steam, SJAEs, and Priming Ejectors.

Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-MS-012 20 S

Main Steam Balancing Line between 3-MS-005 and 3-MS-007 High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-013 24 S

Line from 3-MS-005 to MSR A Header High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-014 24 S

Line from 3-MS-008 to MSR A Header High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-015 20 S

MSR A, BFP Turbine, SJAE, and Priming Ejector Header High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-016 28 S

Main Steam from Steam Gen No 31 to HP Turbine Inlet High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-017 28 S

Main Steam from Steam Gen No 32 to HP Turbine Inlet High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-018 28 S

Main Steam from Steam Gen No 33 to HP Turbine Inlet High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-019 28 S

Main Steam from Steam Gen No 34 to HP Turbine Inlet High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-024 12 S

Main Steam to Reheater Steam Control Station A.

High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-025 8

S Reheater Steam Control Station A line to PCV 1175-1 High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-026 8

S Reheater Steam Control Station A line to PCV 1175-2 High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-028 12 S

Reheater Steam Header A High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-029 6

S Reheater Header to MSR 33A High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-030 6

S Reheater Header to MSR 32A High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-031 6

S Reheater Header to MSR 31A High quality main steam line.

PEPSE NQ 9321-F-20173 Report No. 0700.104-17, Appendix C, Revision 2 Page C-62 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Steam (MS), Unit 3 Section B: SNM Program Lines 3-MS-01: Main Steam from SG to HP Turbine, BFP Turbine, MSRs, Aux. Steam, SJAEs, and Priming Ejectors.

Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-MS-032 1

S PCV-1175-1 Leakoff Line to Condenser Unknown operating conditions P&ID NC 9321-F-20173, 9321-F-20233 Sheet 1 Text19:

3-MS-034 2

S PCV-1175-1 and PCV-1175-2 Leakoff Line to Condenser Unknown operating conditions P&ID NC 9321-F-20233 Sheet 1 Text19:

3-MS-035 12 S

Main Steam to Reheater Steam Control Station B.

High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-036 8

S Reheater Steam Control Station B line to PCV 1175-3 High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-037 8

S Reheater Steam Control Station B line to PCV 1175-4 High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-038 1

S Reheater Steam Control Station B bypass line to PCV 1109 High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-039 12 S

Reheater Steam Header B High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-040 6

S Reheater Header to MSR 31B High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-041 6

S Reheater Header to MSR 32B High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-042 6

S Reheater Header to MSR 33B High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-044 1

S PCV-1175-3 Leakoff Line to Condenser Unknown operating conditions P&ID NC 9321-F-20173, 9321-F-20233 Sheet 2 Text19:

3-MS-045 2

S PCV-1175-3 and PCV-1175-4 Leakoff Line to Condenser Unknown operating conditions P&ID NC 9321-F-20233 Sheet 2 Text19:

3-MS-046 1

S Reheater Cal. Line High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-047 4

S Main Steam to BFP #32 Turbine High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-048 4

S Main Steam to BFP #31 Turbine High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-049 6

S Main Steam to SJAEs and Priming Ejectors High quality main steam line.

PEPSE NQ 9321-F-20173 Report No. 0700.104-17, Appendix C, Revision 2 Page C-63 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Steam (MS), Unit 3 Section B: SNM Program Lines 3-MS-01: Main Steam from SG to HP Turbine, BFP Turbine, MSRs, Aux. Steam, SJAEs, and Priming Ejectors.

Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-MS-050 3

S SJAE Steam Supply Upstream of PCV 1132 High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-051 3

S SJAE Steam Supply Downstream of PCV 1132 Operating conditions unknown.

PEPSE NC 9321-F-20173 Text19:

3-MS-053 3

S SJAE Header Operating conditions unknown.

PEPSE NC 9321-F-20173 Text19:

3-MS-054 2

S Header to SJAE 31 Operating conditions unknown.

PEPSE NC 9321-F-20173 Text19:

3-MS-055 2

S Header to SJAE 32 Operating conditions unknown.

PEPSE NC 9321-F-20173 Text19:

3-MS-056 2

S Header to SJAE 33 Operating conditions unknown.

PEPSE NC 9321-F-20173 Text19:

3-MS-057 S

SJAE Steam Supply via 131-1 Operating conditions unknown.

PEPSE NC 9321-F-20173 Text19:

3-MS-058 S

SJAE Steam Supply via 131-2 Operating conditions unknown.

PEPSE NC 9321-F-20173 Text19:

3-MS-059 S

SJAE Steam Supply via 131-3 Operating conditions unknown.

PEPSE NC 9321-F-20173 Text19:

3-MS-060 S

SJAE Steam Supply via 131-4 Operating conditions unknown.

PEPSE NC 9321-F-20173 Text19:

3-MS-061 S

SJAE Steam Supply via 132-1 Operating conditions unknown.

PEPSE NC 9321-F-20173 Text19:

3-MS-062 S

SJAE Steam Supply via 132-2 Operating conditions unknown.

PEPSE NC 9321-F-20173 Text19:

3-MS-063 S

SJAE Steam Supply via 131-5 Operating conditions unknown.

PEPSE NC 9321-F-20173 Text19:

3-MS-064 S

SJAE Steam Supply via 131-6 Operating conditions unknown.

PEPSE NC 9321-F-20173 Text19:

3-MS-065 S

SJAE Steam Supply via 131-7 Operating conditions unknown.

PEPSE NC 9321-F-20173 Text19:

3-MS-066 S

SJAE Steam Supply via 131-8 Operating conditions unknown.

PEPSE NC 9321-F-20173 Text19:

3-MS-067 S

SJAE Steam Supply via 132-3 Operating conditions unknown.

PEPSE NC 9321-F-20173 Text19:

3-MS-068 S

SJAE Steam Supply via 132-4 Operating conditions unknown.

PEPSE NC 9321-F-20173 Text19:

3-MS-069 S

SJAE Steam Supply via 131-9 Operating conditions unknown.

PEPSE NC 9321-F-20173 Report No. 0700.104-17, Appendix C, Revision 2 Page C-64 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Steam (MS), Unit 3 Section B: SNM Program Lines 3-MS-01: Main Steam from SG to HP Turbine, BFP Turbine, MSRs, Aux. Steam, SJAEs, and Priming Ejectors.

Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-MS-070 S

SJAE Steam Supply via 131-10 Operating conditions unknown.

PEPSE NC 9321-F-20173 Text19:

3-MS-071 S

SJAE Steam Supply via 131-11 Operating conditions unknown.

PEPSE NC 9321-F-20173 Text19:

3-MS-072 S

SJAE Steam Supply via 131-12 Operating conditions unknown.

PEPSE NC 9321-F-20173 Text19:

3-MS-073 S

SJAE Steam Supply via 132-5 Operating conditions unknown.

PEPSE NC 9321-F-20173 Text19:

3-MS-074 S

SJAE Steam Supply via 132-6 Operating conditions unknown.

PEPSE NC 9321-F-20173 Text19:

3-MS-080 12 S

Balancing line between Steam supply lines from Steam Gen No 32 and 34 High quality main steam line.

PEPSE NQ 9321-F-20173 Text19:

3-MS-081 3

S MS-HCV-416-1 leakoff to condenser Operating conditions unknown.

P&ID NC 9321-F-20173 Text19:

3-MS-082 3

S MS-HCV-416-2 leakoff to condenser Operating conditions unknown.

P&ID NC 9321-F-20173 Text19:

3-MS-083 3

S MS-HCV-416-3 leakoff to condenser Operating conditions unknown.

P&ID NC 9321-F-20173 Text19:

3-MS-084 3

S MS-HCV-416-4 leakoff to condenser Operating conditions unknown.

P&ID NC 9321-F-20173 Text19:

3-MS-149 0.75 S

Main Steam Stop Valve drain to 33 Cond.

Operating conditions unknown.

P&ID NS 9321-F-20173 Text19:

3-MS-150 0.75 S

Main Steam Stop Valve drain to 33 Cond.

Operating conditions unknown.

P&ID NS 9321-F-20173 Text19:

3-MS-151 2

S Header to 33 Cond.

Operating conditions unknown.

P&ID NC 9321-F-20173 Text19:

3-MS-162 4

S Main Steam Header to Aux. Steam Upstream of PCV-1257 High quality main steam line.

PEPSE NQ 9321-F-20173, 9321-F-41573 Text19:

3-MS-166 3

S PCV-1257 Bypass High quality main steam line.

PEPSE NQ 9321-F-41573 Text19:

3-MS-168 1

S Main Steam to Mud Drum High quality main steam line.

PEPSE NQ 9321-F-20173, 9321-F-41283 Text19:

3-MS-169 3

S Main Steam to Mud Drum High quality main steam line.

PEPSE NQ 9321-F-41283 Text19:

3-MS-170 3

S Main Steam to Mud Drum High quality main steam line.

PEPSE NQ 9321-F-41283 Report No. 0700.104-17, Appendix C, Revision 2 Page C-65 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Steam (MS), Unit 3 Section B: SNM Program Lines 3-MS-01: Main Steam from SG to HP Turbine, BFP Turbine, MSRs, Aux. Steam, SJAEs, and Priming Ejectors.

Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-MS-173 2.5 S

Main Steam vent to Service Boiler Blowdown Tank roof vent High quality main steam line.

PEPSE NQ 9321-F-41283 3-MS-08: Main Steam Supply to Gland Steam Header Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-MS-152 4

S Main Steam Supply to Gland Seal Regulator Station High quality main steam line.

PEPSE NC 9321-F-20173, 9321-F-20313 Text19:

3-MS-153-A 3

S Gland Seal Steam Supply upstream of PCV-1211 High quality main steam line.

PEPSE NC 9321-F-20313, B237144 Text19:

3-MS-153-B 12 S

Gland Seal Steam Supply downstream of PCV-1211 Operating conditions unknown.

P&ID NC 9321-F-20313, B237144 Text19:

3-MS-157 12 S

Header to Condenser drains Operating conditions unknown.

P&ID NC 9321-F-20313 Text19:

3-MS-157-A 6

S Drain to No. 33 Condenser Operating conditions unknown.

P&ID NC 9321-F-20313 Text19:

3-MS-157-B 0.75 S

Drain to No. 33 Condenser Operating conditions unknown.

P&ID NS 9321-F-20313 Text19:

3-MS-159 12 S

Main Steam to Gland Seal Steam Header.

Operating conditions unknown.

P&ID NC 9321-F-20313, B237144 Text19:

3-MS-160 6

S Gland Steam to Boiler Feed Pump Turbines Flow Conditions Unknown PEPSE NC 9321-F-20313, 9321-F-20243 3-MS-09: H.P. Turbine Control Valve Piping Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-MS-174 S

LH Control Valve Stem Leak-off Lines Operating conditions unknown.

P&ID NS 9321-05-FP-2355 Text19:

3-MS-175 S

RH Control Valve Stem Leak-off Lines Operating conditions unknown.

P&ID NS 9321-05-FP-2355 Text19:

3-MS-176 1.5 S

Upper LH HP Turbine Feed Leakoff Operating conditions unknown.

P&ID NS 9321-05-FP-2355 Report No. 0700.104-17, Appendix C, Revision 2 Page C-66 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Steam (MS), Unit 3 Section B: SNM Program Lines 3-MS-09: H.P. Turbine Control Valve Piping Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-MS-177 1.5 S

Lower LH HP Turbine Feed Leakoff Operating conditions unknown.

P&ID NS 9321-05-FP-2355 Text19:

3-MS-178 1.5 S

Upper RH HP Turbine Feed Leakoff Operating conditions unknown.

P&ID NS 9321-05-FP-2355 Text19:

3-MS-179 1.5 S

Lower LH HP Turbine Feed Leakoff Operating conditions unknown.

P&ID NS 9321-05-FP-2355 Text19:

3-MS-182 1.5 S

HP Turbine Drain Operating conditions unknown.

P&ID NS 9321-05-FP-2355 Text19:

3-MS-201 S

LP Leakoff from Valve Stems to Gland Condenser Operating conditions unknown.

P&ID NC 9321-05-FP-2355, B237144 Section C: Excluded Lines 3-MS-01: Main Steam from SG to HP Turbine, BFP Turbine, MSRs, Aux. Steam, SJAEs, and Priming Ejectors.

Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-MS-020 1.5 E

Main Steam from Gen No 31 bypass to HP Turbine Valve shown closed on P&ID.

P&ID EI 9321-F-20173 Text19:

3-MS-021 1.5 E

Main Steam from Gen No 32 bypass to HP Turbine Valve shown closed on P&ID.

P&ID EI 9321-F-20173 Text19:

3-MS-022 1.5 E

Main Steam from Gen No 33 bypass to HP Turbine Valve shown closed on P&ID.

P&ID EI 9321-F-20173 Text19:

3-MS-023 1.5 E

Main Steam from Gen No 34 bypass to HP Turbine Valve shown closed on P&ID.

P&ID EI 9321-F-20173 Text19:

3-MS-027 1

E Reheater Steam Control Station A bypass line to PCV 1108 Valve shown closed on P&ID.

P&ID EI 9321-F-20173 Text19:

3-MS-033 1

E PCV-1175-2 Leakoff Line to Condenser Valves are closed for Unit 2 System Description 18.

EI 9321-F-20173, 9321-F-20233 Sheet 1 Text19:

3-MS-043 1

E PCV-1175-4 Leakoff Line to Condenser Valves are closed for Unit 2 System Description 18.

EI 9321-F-20173, 9321-F-20233 Sheet 2 Report No. 0700.104-17, Appendix C, Revision 2 Page C-67 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Steam (MS), Unit 3 Section C: Excluded Lines 3-MS-01: Main Steam from SG to HP Turbine, BFP Turbine, MSRs, Aux. Steam, SJAEs, and Priming Ejectors.

Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-MS-052 2

E PCV 1132 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20173 Text19:

3-MS-075-A 6

E Main Steam to Priming Ejectors Header Upstream of PCV 1133 Priming Ejectors are only used during startup ( infrequent use)

P&ID EI 9321-F-20173 Text19:

3-MS-075-B 6

E Main Steam to Priming Ejectors Header Downstream of PCV 1133 Priming Ejectors are only used during startup ( infrequent use)

P&ID EI 9321-F-20173 Text19:

3-MS-075-C 6

E PCV 1133 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20173 Text19:

3-MS-076 6

E Priming Ejector Header to PE 32 and 33 Priming Ejectors are only used during startup ( infrequent use)

P&ID EI 9321-F-20173 Text19:

3-MS-077 3

E Priming Ejectors Header to PE 31 Priming Ejectors are only used during startup ( infrequent use)

P&ID EI 9321-F-20173 Text19:

3-MS-078 3

E Priming Ejectors Header to PE 32 Priming Ejectors are only used during startup ( infrequent use)

P&ID EI 9321-F-20173 Text19:

3-MS-079 3

E Priming Ejectors Header to PE 33 Priming Ejectors are only used during startup ( infrequent use)

P&ID EI 9321-F-20173 Text19:

3-MS-164 1

E MS-71 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41573 Text19:

3-MS-167 4

E Vent off of Aux Steam Header Valve shown closed on P&ID.

P&ID EI 9321-F-41573 Text19:

3-MS-171 2

E TCV 133 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41283 Text19:

3-MS-172 1

E PCV 1151 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41283 3-MS-08: Main Steam Supply to Gland Steam Header Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-MS-154-A 3

E Gland Seal Steam Supply upstream of PCV-1212 Valve shown closed on P&ID.

P&ID EI 9321-F-20313, B237144 Text19:

3-MS-154-B 0.5 E

MS-192 bypass to Gland Seal Steam Supply Valve shown closed on P&ID.

P&ID EI 9321-F-20313 Report No. 0700.104-17, Appendix C, Revision 2 Page C-68 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Steam (MS), Unit 3 Section C: Excluded Lines 3-MS-08: Main Steam Supply to Gland Steam Header Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-MS-154-C 2

E Drain to condenser Valve shown closed on P&ID.

P&ID EI 9321-F-20313 Text19:

3-MS-154-D 12 E

Gland Seal Steam Supply downstream of PCV-1212 Valve shown closed on P&ID.

P&ID EI 9321-F-20313, B237144 Text19:

3-MS-155 3

E PCV-1211 and 1212 bypass line Valve shown closed on P&ID.

P&ID EI 9321-F-20313, B237144 Text19:

3-MS-156-A 10 E

Vent to Atmosphere Valve shown closed on P&ID.

P&ID EI 9321-F-20313 Text19:

3-MS-156-B 8

E Vent to Atmosphere Valve shown closed on P&ID.

P&ID EI 9321-F-20313 Text19:

3-MS-158-A 2

E Drain from H.P. Turbine to Condenser No. 33 Valve shown closed on P&ID.

P&ID EI 9321-F-20313 Text19:

3-MS-158-B 2

E Drain from H.P. Turbine to Condenser No. 33 Valve shown closed on P&ID.

P&ID EI 9321-F-20313 Text19:

3-MS-161 2

E Gland Steam to Drain Collecting Tank Valve shown closed on P&ID.

P&ID EI 9321-F-20313 3-MS-09: H.P. Turbine Control Valve Piping Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-MS-180 1.5 E

HP Turbine Drain from Far Side Inlet Replaced with Chrome-moly IP3-RPT-MULT-03162 EM 9321-05-FP-2355 Text19:

3-MS-181 1.5 E

HP Turbine Drain from Near Side Inlet Replaced with Chrome-moly IP3-RPT-MULT-03162 EM 9321-05-FP-2355 Report No. 0700.104-17, Appendix C, Revision 2 Page C-69 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Moisture Separator Reheater Drains (MSD), Unit 3 Section A: CHECWORKS Model Lines 3-MSD-01: Moisture Separator Drains to the Heater Drain Tank Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-MSD-043 12 M

MSD-01.1A_1 MSEP 31A to HDR:

MSR 31A drain PEPSE 9321-F-20233 Sheet 1 Text19:

3-MSD-044 12 M

MSD-01.1A_2 MSEP 31A to HDR:

MSR 31A drain PEPSE 9321-F-20233 Sheet 1 Text19:

3-MSD-045 12 M

MSD-01.1A_3 MSEP 31A to HDR:

MSR 31A drain PEPSE 9321-F-20233 Sheet 1 Text19:

3-MSD-046 12 M

MSD-01.2A MSEP 31A DR HDR:

MSR 31A drain header to MS Drain Tank PEPSE 9321-F-20233 Sheet 1 Text19:

3-MSD-047 12 M

MSD-01.3A HDR to MSEP TK 31A:

MSR 31A drain to MS Drain Tank PEPSE 9321-F-20233 Sheet 1 Text19:

3-MSD-048 12 M

MSD-01.6A_1 MSEP 32A to HDR:

MSR 32A drain PEPSE 9321-F-20233 Sheet 1 Text19:

3-MSD-049 12 M

MSD-01.6A_2 MSEP 32A to HDR:

MSR 32A drain PEPSE 9321-F-20233 Sheet 1 Text19:

3-MSD-050 12 M

MSD-01.6A_3 MSEP 32A to HDR:

MSR 32A drain PEPSE 9321-F-20233 Sheet 1 Text19:

3-MSD-051 12 M

MSD-01.7A MSEP 32A DR HDR:

MSR 32A drain header to MS Drain Tank PEPSE 9321-F-20233 Sheet 1 Text19:

3-MSD-052 12 M

MSD-01.8A HDR to MSEP TK 32A:

MSR 32A drain to MS Drain Tank PEPSE 9321-F-20233 Sheet 1 Text19:

3-MSD-053 12 M

MSD-01.11A_1 MSEP 33A to HDR:

MSR 33A drain PEPSE 9321-F-20233 Sheet 1 Text19:

3-MSD-054 12 M

MSD-01.11A_2 MSEP 33A to HDR:

MSR 33A drain PEPSE 9321-F-20233 Sheet 1 Text19:

3-MSD-055 12 M

MSD-01.11A_3 MSEP 33A to HDR:

MSR 33A drain PEPSE 9321-F-20233 Sheet 1 Report No. 0700.104-17, Appendix C, Revision 2 Page C-70 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Moisture Separator Reheater Drains (MSD), Unit 3 Section A: CHECWORKS Model Lines 3-MSD-01: Moisture Separator Drains to the Heater Drain Tank Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-MSD-056 12 M

MSD-01.12A MSEP 33A DR HDR:

MSR 33A drain header to MS Drain Tank PEPSE 9321-F-20233 Sheet 1 Text19:

3-MSD-057 12 M

MSD-01.13A HDR to MSEP TK 33A:

MSR 33A drain to MS Drain Tank PEPSE 9321-F-20233 Sheet 1 Text19:

3-MSD-058 12 M

MSD-01.1B_1 MSEP 31B to HDR:

MSR 31B drain PEPSE 9321-F-20233 Sheet 2 Text19:

3-MSD-059 12 M

MSD-01.1B_2 MSEP 31B to HDR:

MSR 31B drain PEPSE 9321-F-20233 Sheet 2 Text19:

3-MSD-060 12 M

MSD-01.1B_3 MSEP 31B to HDR:

MSR 31B drain PEPSE 9321-F-20233 Sheet 2 Text19:

3-MSD-061 12 M

MSD-01.2B MSEP 31B DR HDR:

MSR 31B drain header to MS Drain Tank PEPSE 9321-F-20233 Sheet 2 Text19:

3-MSD-062 12 M

MSD-01.3B HDR to MSEP TK 31B:

MSR 31B drain to MS Drain Tank PEPSE 9321-F-20233 Sheet 2 Text19:

3-MSD-063 12 M

MSD-01.6B_1 MSEP 32B to HDR:

MSR 32B drain PEPSE 9321-F-20233 Sheet 2 Text19:

3-MSD-064 12 M

MSD-01.6B_2 MSEP 32B to HDR:

MSR 32B drain PEPSE 9321-F-20233 Sheet 2 Text19:

3-MSD-065 12 M

MSD-01.6B_3 MSEP 32B to HDR:

MSR 32B drain PEPSE 9321-F-20233 Sheet 2 Text19:

3-MSD-066 12 M

MSD-01.7B MSEP 32B DR HDR:

MSR 32B drain header to MS Drain Tank PEPSE 9321-F-20233 Sheet 2 Text19:

3-MSD-067 12 M

MSD-01.8B HDR to MSEP TK 32B:

MSR 32B drain to MS Drain Tank PEPSE 9321-F-20233 Sheet 2 Report No. 0700.104-17, Appendix C, Revision 2 Page C-71 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Moisture Separator Reheater Drains (MSD), Unit 3 Section A: CHECWORKS Model Lines 3-MSD-01: Moisture Separator Drains to the Heater Drain Tank Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-MSD-068 12 M

MSD-01.11B_1 MSEP 33B to HDR:

MSR 33B drain PEPSE 9321-F-20233 Sheet 2 Text19:

3-MSD-069 12 M

MSD-01.11B_2 MSEP 33B to HDR:

MSR 33B drain PEPSE 9321-F-20233 Sheet 2 Text19:

3-MSD-070 12 M

MSD-01.11B_3 MSEP 33B to HDR:

MSR 33B drain PEPSE 9321-F-20233 Sheet 2 Text19:

3-MSD-071 12 M

MSD-01.12B MSEP 33B DR HDR:

MSR 33B drain header to MS Drain Tank PEPSE 9321-F-20233 Sheet 2 Text19:

3-MSD-072 12 M

MSD-01.13B HDR to MSEP TK 33B:

MSR 33B drain to MS Drain Tank PEPSE 9321-F-20233 Sheet 2 3-MSD-02: Reheater Drains to #36 Feedwater Heaters Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-MSD-007 6

M RHD-01.1A_1 RH 31A to TK 31A:

Reheater 31A to Reheater Drain Tank PEPSE 9321-F-20233 Sheet 1 Text19:

3-MSD-008 6

M RHD-01.3A_1 RH 32A to TK 32A:

Reheater 32A to Reheater Drain Tank PEPSE 9321-F-20233 Sheet 1 Text19:

3-MSD-009 6

M RHD-01.10A_1 RH 33A to TK 33A:

Reheater 33A to Reheater Drain Tank PEPSE 9321-F-20233 Sheet 1 Text19:

3-MSD-010 6

M RHD-01.1B_1 RH 31B to TK 31B:

Reheater 31B to Reheater Drain Tank PEPSE 9321-F-20233 Sheet 2 Text19:

3-MSD-011 6

M RHD-01.3B_1 RH 32B to TK 32B:

Reheater 32B to Reheater Drain Tank PEPSE 9321-F-20233 Sheet 2 Text19:

3-MSD-012 6

M RHD-01.10B_1 RH 33B to TK 33B:

Reheater 33B to Reheater Drain Tank PEPSE 9321-F-20233 Sheet 2 Report No. 0700.104-17, Appendix C, Revision 2 Page C-72 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Moisture Separator Reheater Drains (MSD), Unit 3 Section A: CHECWORKS Model Lines 3-MSD-02: Reheater Drains to #36 Feedwater Heaters Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-MSD-013 6

M RHD-01.1A_2 TK 31A to A HDR:

Reheater Drain Tank 31A Drain to Header PEPSE 9321-F-20233 Sheet 1 Text19:

3-MSD-014 8

M RHD-01.3A_2 TK 32A to A HDR:

Reheater Drain Tank 32A Drain to Header PEPSE 9321-F-20233 Sheet 1 Text19:

3-MSD-015 6

M RHD-01.10A_2 TK 33A to A HDR:

Reheater Drain Tank 33A Drain to Header PEPSE 9321-F-20233 Sheet 1 Text19:

3-MSD-016 10 M

RHD-02.8A TK A HDR to FWH 36:

Reheater Drain Tank Header Downstream of Reheater 32A and 33A Inlet PEPSE 9321-F-20233 Sheet 1 Text19:

3-MSD-017 10 M

RHD-02.9A TK A HDR to FWH 36:

"A" Reheater Drain Tank Header to

  1. 36 FWHs PEPSE 9321-F-20233 Sheet 1, 9321-F-20233 Sheet 2 Text19:

3-MSD-018 8

M RHD-02.10A TK A HDR to FWH 36:

"A" Reheater Drain Tank Header to FWH 36A and 36B PEPSE 9321-F-20233 Sheet 2 Text19:

3-MSD-019 6

M RHD-02.11A A HDR to FWH 36A:

"A" Reheater Drain Tank Header to FWH 36A PEPSE 9321-F-20233 Sheet 2 Text19:

3-MSD-020 6

M RHD-02.13A A HDR to FWH 36B:

"A" Reheater Drain Tank Header to FWH 36B PEPSE 9321-F-20233 Sheet 2 Text19:

3-MSD-021 6

M RHD-02.15A A HDR to FWH 36C:

"A" Reheater Drain Tank Header to FWH 36C PEPSE 9321-F-20233 Sheet 2 Text19:

3-MSD-022 6

M RHD-01.1B_2 TK 31B to B HDR:

Reheater Drain Tank 31B Drain to Header PEPSE 9321-F-20233 Sheet 2 Report No. 0700.104-17, Appendix C, Revision 2 Page C-73 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Moisture Separator Reheater Drains (MSD), Unit 3 Section A: CHECWORKS Model Lines 3-MSD-02: Reheater Drains to #36 Feedwater Heaters Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-MSD-023 10 M

RHD-01.3B_2 TK 32B to B HDR:

Reheater Drain Tank 32B Drain to Header PEPSE 9321-F-20233 Sheet 2 Text19:

3-MSD-024 6

M RHD-01.10B_2 TK 33B to B HDR:

Reheater Drain Tank 33B Drain to Header PEPSE 9321-F-20233 Sheet 2 Text19:

3-MSD-025 8

M RHD-02.7B TK B HDR to FWH 36:

Reheater Drain Tank Header Downstream of Reheater 31B and 33B Inlet PEPSE 9321-F-20233 Sheet 2 Text19:

3-MSD-026 10 M

RHD-02.8B TK B HDR to FWH 36:

"B" Reheater Drain Tank Header to

  1. 36 FWHs PEPSE 9321-F-20233 Sheet 2 Text19:

3-MSD-027 10 M

RHD-02.9B TK B HDR to FWH 36:

"B" Reheater Drain Tank Header to FWH 36A and 36B PEPSE 9321-F-20233 Sheet 2 Text19:

3-MSD-028 6

M RHD-02.10B B HDR to FWH 36A:

"B" Reheater Drain Tank Header to FWH 36A PEPSE 9321-F-20233 Sheet 2 Text19:

3-MSD-029 6

M RHD-02.12B B HDR to FWH 36B:

"B" Reheater Drain Tank Header to FWH 36B PEPSE 9321-F-20233 Sheet 2 Text19:

3-MSD-030 6

M RHD-02.14B B HDR to FWH 36C:

"B" Reheater Drain Tank Header to FWH 36C PEPSE 9321-F-20233 Sheet 2 Report No. 0700.104-17, Appendix C, Revision 2 Page C-74 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Moisture Separator Reheater Drains (MSD), Unit 3 Section B: SNM Program Lines 3-MSD-01: Moisture Separator Drains to the Heater Drain Tank Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-MSD-073 2.5 S

MS Drain Tank 31A vent to MSR Operating conditions unknown.

PEPSE NC 9321-F-20233 Sheet 1 Text19:

3-MSD-074 2.5 S

MS Drain Tank 32A vent to MSR Operating conditions unknown.

PEPSE NC 9321-F-20233 Sheet 1 Text19:

3-MSD-075 2.5 S

MS Drain Tank 33A vent to MSR Operating conditions unknown.

PEPSE NC 9321-F-20233 Sheet 1 Text19:

3-MSD-076 2.5 S

MS Drain Tank 31B vent to MSR Operating conditions unknown.

PEPSE NC 9321-F-20233 Sheet 2 Text19:

3-MSD-077 2.5 S

MS Drain Tank 32B vent to MSR Operating conditions unknown.

PEPSE NC 9321-F-20233 Sheet 2 Text19:

3-MSD-078 2.5 S

MS Drain Tank 33B vent to MSR Operating conditions unknown.

PEPSE NC 9321-F-20233 Sheet 2 Text19:

3-MSD-079-A 8

S MSD-01.4A TK 31A to HD TK: MS Drain Tank 31A Drain Header The nozzle is the only susceptible component in the line.

SFA Model NL 9321-F-20233 Sheet 1 Text19:

3-MSD-080-A 8

S MSD-01.9A TK 32A to HD TK: MS Drain Tank 32A Drain Nozzle The nozzle is the only susceptible component in this line.

SFA Model NL 9321-F-20233 Sheet 1 Text19:

3-MSD-081-A 8

S MSD-01.14A TK 33A to HD TK: MS Drain Tank 33A Drain Nozzle The nozzle is the only susceptible component in this line.

SFA Model NL 9321-F-20233 Sheet 1 Text19:

3-MSD-082-A 8

S MSD-01.4B TK 31B to HD TK: MS Drain Tank 31B Drain Nozzle The nozzle is the only susceptible component in this line.

SFA Model NL 9321-F-20233 Sheet 2 Text19:

3-MSD-083-A 8

S MSD-01.9B TK 32B to HD TK: MS Drain Tank 32B Drain Nozzle The nozzle is the only susceptible component in this line.

SFA Model NL 9321-F-20233 Sheet 2 Text19:

3-MSD-084-A 8

S MSD-01.14B TK 33B to HD TK: MS Drain Tank 33B Drain Nozzle The nozzle is the only susceptible component in this line.

SFA Model NL 9321-F-20233 Sheet 2 Text19:

3-MSD-085-B 6

S MSD-01.4A TK 31A to HD TK: MS Drain Tank 31A Drain Nozzle to Heater Drain Tank The nozzle is the only susceptible component in this line.

SFA Model NL 9321-F-20233 Sheet 1 Text19:

3-MSD-086-B 6

S MSD-01.9A TK 32A to HD TK: MS Drain Tank 32A Drain Nozzle to Heater Drain Tank The nozzle is the only susceptible component in this line.

SFA Model NL 9321-F-20233 Sheet 1 Report No. 0700.104-17, Appendix C, Revision 2 Page C-75 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Moisture Separator Reheater Drains (MSD), Unit 3 Section B: SNM Program Lines 3-MSD-01: Moisture Separator Drains to the Heater Drain Tank Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-MSD-087-B 6

S MSD-01.14A TK 33A to HD TK: MS Drain Tank 33A Drain Nozzle to Heater Drain Tank The nozzle is the only susceptible component in this line.

SFA Model NL 9321-F-20233 Sheet 1 Text19:

3-MSD-088 6

S MSD-01.4B TK 31B to HD TK: MS Drain Tank 31B Drain to Heater Drain Tank FAC susceptibility is localized in only a few components in this line.

SFA Model NL 9321-F-20233 Sheet 2, 9321-F-20233 Sheet 1 Text19:

3-MSD-089 6

S MSD-01.9B TK 32B to HD TK: MS Drain Tank 32B Drain to Heater Drain Tank FAC susceptibility is localized in only a few components in this line.

SFA Model NL 9321-F-20233 Sheet 2, 9321-F-20233 Sheet 1 Text19:

3-MSD-090 6

S MSD-01.14B TK 33B to HD TK: MS Drain Tank 33B Drain to Heater Drain Tank FAC susceptibility is localized in only a few components in this line.

SFA Model NL 9321-F-20233 Sheet 2, 9321-F-20233 Sheet 1 3-MSD-02: Reheater Drains to #36 Feedwater Heaters Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-MSD-001 2.5 S

Reheater Drain Tank 31A Vent to MSR Operating conditions unknown.

P&ID NC 9321-F-20233 Sheet 1 Text19:

3-MSD-002 2.5 S

Reheater Drain Tank 32A Vent to MSR Operating conditions unknown.

P&ID NC 9321-F-20233 Sheet 1 Text19:

3-MSD-003 2.5 S

Reheater Drain Tank 33A Vent to MSR Operating conditions unknown.

P&ID NC 9321-F-20233 Sheet 1 Text19:

3-MSD-004 2.5 S

Reheater Drain Tank 31B Vent to MSR Operating conditions unknown.

P&ID NC 9321-F-20233 Sheet 2 Text19:

3-MSD-005 2.5 S

Reheater Drain Tank 32B Vent to MSR Operating conditions unknown.

P&ID NC 9321-F-20233 Sheet 2 Text19:

3-MSD-006 2.5 S

Reheater Drain Tank 33B Vent to MSR Operating conditions unknown.

P&ID NC 9321-F-20233 Sheet 2 Text19:

3-MSD-031 6

S Reheater 31A to Condenser 33 Operating conditions unknown.

P&ID NC 9321-F-20233 Sheet 1 Report No. 0700.104-17, Appendix C, Revision 2 Page C-76 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Moisture Separator Reheater Drains (MSD), Unit 3 Section B: SNM Program Lines 3-MSD-02: Reheater Drains to #36 Feedwater Heaters Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-MSD-032 6

S Reheater 32A to Condenser 32 Operating conditions unknown.

P&ID NC 9321-F-20233 Sheet 1 Text19:

3-MSD-033 8

S Reheater 33A to Condenser 33 Operating conditions unknown.

P&ID NC 9321-F-20233 Sheet 1 Text19:

3-MSD-034 6

S Reheater 31B to Condenser 31 Operating conditions unknown.

P&ID NC 9321-F-20233 Sheet 2 Text19:

3-MSD-035 6

S Reheater 32B to Condenser 32 Operating conditions unknown.

P&ID NC 9321-F-20233 Sheet 2 Text19:

3-MSD-036 6

S Reheater 33B to Condenser 31 Operating conditions unknown.

P&ID NC 9321-F-20233 Sheet 2 Section C: Excluded Lines 3-MSD-01: Moisture Separator Drains to the Heater Drain Tank Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-MSD-079-B 8

E MSD-01.4A TK 31A to HD TK: MS Drain Tank 31A Drain Header This line has been replaced with CrMo.

SFA Model EM 9321-F-20233 Sheet 1 Text19:

3-MSD-080-B 8

E MSD-01.9A TK 32A to HD TK: MS Drain Tank 32A Drain Header This line has been replaced with CrMo.

SFA Model EM 9321-F-20233 Sheet 1 Text19:

3-MSD-081-B 8

E MSD-01.14A TK 33A to HD TK: MS Drain Tank 33A Drain Header This line has been replaced with CrMo.

SFA Model EM 9321-F-20233 Sheet 1 Text19:

3-MSD-082-B 8

E MSD-01.4B TK 31B to HD TK: MS Drain Tank 31B Drain Header This line has been replaced with CrMo.

SFA Model EM 9321-F-20233 Sheet 2 Text19:

3-MSD-083-B 8

E MSD-01.9B TK 32B to HD TK: MS Drain Tank 32B Drain Header This line has been replaced with CrMo.

SFA Model EM 9321-F-20233 Sheet 2 Text19:

3-MSD-084-B 8

E MSD-01.14B TK 33B to HD TK: MS Drain Tank 33B Drain Header This line has been replaced with CrMo.

SFA Model EM 9321-F-20233 Sheet 2 Text19:

3-MSD-085-A 6

E MSD-01.4A TK 31A to HD TK: MS Drain Tank 31A Drain to Heater Drain Tank This line has been replaced with CrMo.

SFA Model EM 9321-F-20233 Sheet 1 Report No. 0700.104-17, Appendix C, Revision 2 Page C-77 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Moisture Separator Reheater Drains (MSD), Unit 3 Section C: Excluded Lines 3-MSD-01: Moisture Separator Drains to the Heater Drain Tank Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-MSD-086-A 6

E MSD-01.9A TK 32A to HD TK: MS Drain Tank 32A Drain to Heater Drain Tank This line has been replaced with CrMo.

SFA Model EM 9321-F-20233 Sheet 1 Text19:

3-MSD-087-A 6

E MSD-01.14A TK 33A to HD TK: MS Drain Tank 33A Drain to Heater Drain Tank This line has been replaced with CrMo.

SFA Model EM 9321-F-20233 Sheet 1 Text19:

3-MSD-091 6

E MS Drain Tank 31A Drain to Drains Collecting Tank Line only operates during startup, shutdown, and high-level conditions.

System Description 18.0, Rev. 5, pg. 23 EI 9321-F-20233 Sheet 1 Text19:

3-MSD-092 6

E MS Drain Tank 32A Drain to Drains Collecting Tank Line only operates during startup, shutdown, and high-level conditions.

System Description 18.0, Rev. 5, pg. 23 EI 9321-F-20233 Sheet 1 Text19:

3-MSD-093 6

E MS Drain Tank 33A Drain to Drains Collecting Tank Line only operates during startup, shutdown, and high-level conditions.

System Description 18.0, Rev. 5, pg. 23 EI 9321-F-20233 Sheet 1 Text19:

3-MSD-094 6

E MS Drain Tank 31B Drain to Drains Collecting Tank Line only operates during startup, shutdown, and high-level conditions.

System Description 18.0, Rev. 5, pg. 23 EI 9321-F-20233 Sheet 2 Text19:

3-MSD-095 6

E MS Drain Tank 32B Drain to Drains Collecting Tank Line only operates during startup, shutdown, and high-level conditions.

System Description 18.0, Rev. 5, pg. 23 EI 9321-F-20233 Sheet 2 Text19:

3-MSD-096 6

E MS Drain Tank 33B Drain to Drains Collecting Tank Line only operates during startup, shutdown, and high-level conditions.

System Description 18.0, Rev. 5, pg. 23 EI 9321-F-20233 Sheet 2 Report No. 0700.104-17, Appendix C, Revision 2 Page C-78 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Steam Traps (MST), Unit 3 Section B: SNM Program Lines 3-MST-01: Main Steam lines surrounding Main Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-MST-085-A 1.5 S

Main steam to MST-1 High quality main steam line.

PEPSE NS 9321-F-20413 Text19:

3-MST-085-B 1.5 S

MST-1 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20413 Text19:

3-MST-086-A 1.5 S

Main steam to MST-2 High quality main steam line.

PEPSE NS 9321-F-20413 Text19:

3-MST-086-B 1.5 S

MST-2 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20413 Text19:

3-MST-087-A 1.5 S

Main steam to MST-3 High quality main steam line.

PEPSE NS 9321-F-20413 Text19:

3-MST-087-B 1.5 S

MST-3 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20413 Text19:

3-MST-088-A 1.5 S

Main Steam from Drain Pot to MST-4 High quality main steam line.

PEPSE NS 9321-F-20413 Text19:

3-MST-088-B 1

S Main Steam from MS-1-34 US Leakoff to MST-4.

High quality main steam line.

PEPSE NS 9321-F-20413 Text19:

3-MST-088-C 1.5 S

MST-4 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20413 Text19:

3-MST-089-A 1.25 S

Main Steam from MS-1-31 US Leakoff to MST-5 High quality main steam line.

PEPSE NS 9321-F-20413 Text19:

3-MST-089-B 1.25 S

MST-5 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20413 Text19:

3-MST-090-A 1

S Main Steam from MS-1-31 US Leakoff to MST-6 High quality main steam line.

PEPSE NS 9321-F-20413 Text19:

3-MST-090-B 1

S MST-6 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20413 Text19:

3-MST-091-A 1

S Main Steam from MS-2-31 DS Leakoff to MST-8 High quality main steam line.

PEPSE NS 9321-F-20413 Text19:

3-MST-091-B 1

S MST-8 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20413 Text19:

3-MST-092-A 1

S Main Steam from MS-2-32 DS Leakoff to MST-9 High quality main steam line.

PEPSE NS 9321-F-20413 Text19:

3-MST-092-B 1

S MST-9 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20413 Report No. 0700.104-17, Appendix C, Revision 2 Page C-79 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Steam Traps (MST), Unit 3 Section B: SNM Program Lines 3-MST-01: Main Steam lines surrounding Main Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-MST-093-A 1

S Main Steam from MS-1-32 US Leakoff to MST-10 High quality main steam line.

PEPSE NS 9321-F-20413 Text19:

3-MST-093-B 1

S MST-10 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20413 Text19:

3-MST-094-A 1

S Main Steam from MS-1-32 US Leakoff to MST-12 High quality main steam line.

PEPSE NS 9321-F-20413 Text19:

3-MST-094-B 1

S MST-12 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20413 Text19:

3-MST-095-A 1

S Main Steam from MS-1-33 US Leakoff to MST-13 High quality main steam line.

PEPSE NS 9321-F-20413 Text19:

3-MST-095-B 1

S MST-13 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20413 Text19:

3-MST-096-A 1

S Main Steam from MS-1-33 US Leakoff to MST-14 High quality main steam line.

PEPSE NS 9321-F-20413 Text19:

3-MST-096-B 1

S MST-14 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20413 Text19:

3-MST-097-A 1

S Main Steam from MS-2-33 US Leakoff to MST-16 High quality main steam line.

PEPSE NS 9321-F-20413 Text19:

3-MST-097-B 1

S MST-16 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20413 Text19:

3-MST-098-A 1

S Main Steam from MS-1-34 US Leakoff to MST-18 High quality main steam line.

PEPSE NS 9321-F-20413 Text19:

3-MST-098-B 1

S MST-18 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20413 Text19:

3-MST-099-A 1

S Main Steam from MS-2-34 DS Leakoff to MST-20 High quality main steam line.

PEPSE NS 9321-F-20413 Text19:

3-MST-099-B 1

S MST-20 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20413 Text19:

3-MST-100-A 1.5 S

Main Steam to MST-21 High quality main steam line.

PEPSE NS 9321-F-20413 Text19:

3-MST-100-B 1.5 S

MST-21 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20413 Text19:

3-MST-101-A 1.5 S

Main Steam to MST-22 High quality main steam line.

PEPSE NS 9321-F-20413 Report No. 0700.104-17, Appendix C, Revision 2 Page C-80 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Steam Traps (MST), Unit 3 Section B: SNM Program Lines 3-MST-01: Main Steam lines surrounding Main Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-MST-101-B 1.5 S

MST-22 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20413 Text19:

3-MST-102-A 1.5 S

Main Steam to MST-23 High quality main steam line.

PEPSE NS 9321-F-20413 Text19:

3-MST-102-B 1.5 S

MST-23 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20413 Text19:

3-MST-103-A 1

S Main Steam to MST-24 via Steam Dump Lines Pressurized line with flow to steam trap.

PEPSE NS 9321-F-20413 Text19:

3-MST-103-B 1

S MST-24 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20413 Text19:

3-MST-104-A 1

S Main Steam to MST-25 via Steam Dump Lines Pressurized line with flow to steam trap.

PEPSE NS 9321-F-20413 Text19:

3-MST-104-B 1

S MST-25 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20413 Text19:

3-MST-105-A 1.25 S

Main Steam to MST-26 via Steam Dump Lines Pressurized line with flow to steam trap.

PEPSE NS 9321-F-20423 Text19:

3-MST-105-B 1.25 S

MST-26 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20423 Text19:

3-MST-106-A 1

S Main Steam to MST-27 via Steam Dump Lines Pressurized line with flow to steam trap.

PEPSE NS 9321-F-20413 Text19:

3-MST-106-B 1.25 S

MST-27 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20413 Text19:

3-MST-107-A 1.25 S

Main Steam to MST-28 via Steam Dump Lines Pressurized line with flow to steam trap.

PEPSE NS 9321-F-20423 Text19:

3-MST-107-B 1.25 S

MST-28 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20423 Text19:

3-MST-108-A 1.25 S

Main Steam to MST-29 via Steam Dump Lines Pressurized line with flow to steam trap.

PEPSE NS 9321-F-20423 Text19:

3-MST-108-B 1.25 S

MST-29 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20423 Text19:

3-MST-109-A 1

S Main Steam to MST-30 High quality main steam line.

PEPSE NS 9321-F-20423 Text19:

3-MST-109-B 1

S MST-30 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20423 Report No. 0700.104-17, Appendix C, Revision 2 Page C-81 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Steam Traps (MST), Unit 3 Section B: SNM Program Lines 3-MST-01: Main Steam lines surrounding Main Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-MST-110-A 1

S Main Steam to MST-31 High quality main steam line.

PEPSE NS 9321-F-20423 Text19:

3-MST-110-B 1

S MST-31 to Header Operating conditions unknown.

P&ID NS 9321-F-20423 Text19:

3-MST-110-D 1

S Header to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20423 Text19:

3-MST-111-A 1

S Main Steam to MST-32 High quality main steam line.

PEPSE NS 9321-F-20423 Text19:

3-MST-111-B 1

S MST-32 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20423 Text19:

3-MST-112-B 1

S MST-33 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20423 Text19:

3-MST-113-A 1.25 S

Main Steam to MST-34 High quality main steam line.

PEPSE NS 9321-F-20423 Text19:

3-MST-113-B 1.25 S

MST-34 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20423 Text19:

3-MST-114-A 1

S Main Steam to MST-35 High quality main steam line.

PEPSE NS 9321-F-20423 Text19:

3-MST-114-B 1

S MST-35 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20423 Text19:

3-MST-115-A 1

S Main Steam to MST-36 High quality main steam line.

PEPSE NS 9321-F-20413 Text19:

3-MST-115-B 1

S MST-36 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20413 Text19:

3-MST-116-A 1

S Main Steam to MST-37 High quality main steam line.

PEPSE NS 9321-F-20423 Text19:

3-MST-116-B 1

S MST-37 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20423 Text19:

3-MST-117-A 1

S Main Steam to MST-38 High quality main steam line.

PEPSE NS 9321-F-20423 Text19:

3-MST-117-B 1

S MST-38 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20423 Text19:

3-MST-118-A 1

S Main Steam to MST-39 High quality main steam line.

PEPSE NS 9321-F-20423 Text19:

3-MST-118-B 1

S MST-39 to Header Operating conditions unknown.

P&ID NS 9321-F-20423 Text19:

3-MST-118-D 1.25 S

Header to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20423 Text19:

3-MST-119-A 1

S Main Steam to MST-40 High quality main steam line.

PEPSE NS 9321-F-20423 Report No. 0700.104-17, Appendix C, Revision 2 Page C-82 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Steam Traps (MST), Unit 3 Section B: SNM Program Lines 3-MST-01: Main Steam lines surrounding Main Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-MST-119-B 1

S MST-40 to Header Operating conditions unknown.

P&ID NS 9321-F-20423 Text19:

3-MST-120-A 1

S Main Steam to MST-41 High quality main steam line.

PEPSE NS 9321-F-20413 Text19:

3-MST-120-B 1

S MST-41 to Header Operating conditions unknown.

P&ID NS 9321-F-20413 Text19:

3-MST-121-A 1.25 S

Main Steam to MST-42 via Steam Dump Lines Pressurized line with flow to steam trap.

PEPSE NS 9321-F-20423 Text19:

3-MST-121-B 1.25 S

MST-42 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20423 Text19:

3-MST-122-A 1.25 S

Main Steam to MST-43 via Steam Dump Lines Pressurized line with flow to steam trap.

PEPSE NS 9321-F-20423 Text19:

3-MST-122-B 1.25 S

MST-43 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20423 Text19:

3-MST-123-A 1.25 S

Main Steam to MST-44 via Steam Dump Lines Pressurized line with flow to steam trap.

PEPSE NS 9321-F-20423 Text19:

3-MST-123-B 1.25 S

MST-44 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20423 Text19:

3-MST-124-A 1.25 S

Main Steam to MST-45 via Steam Dump Lines Pressurized line with flow to steam trap.

PEPSE NS 9321-F-20423 Text19:

3-MST-124-B 1.25 S

MST-45 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20423 Text19:

3-MST-125-A 1

S Main Steam to MST-46 via Steam Dump Lines Pressurized line with flow to steam trap.

PEPSE NS 9321-F-20423 Text19:

3-MST-125-B 1

S MST-46 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20423 Text19:

3-MST-126-A 1

S Main Steam to MST-47 via Steam Dump Lines Pressurized line with flow to steam trap.

PEPSE NS 9321-F-20423 Text19:

3-MST-126-B 1

S MST-47 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20423 Text19:

3-MST-127-A 1

S Main Steam to MST-48 High quality main steam line.

PEPSE NS 9321-F-20423 Text19:

3-MST-127-B 1

S MST-48 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20423 Report No. 0700.104-17, Appendix C, Revision 2 Page C-83 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Steam Traps (MST), Unit 3 Section B: SNM Program Lines 3-MST-01: Main Steam lines surrounding Main Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-MST-128-A 1

S Main Steam to MST-49 High quality main steam line.

PEPSE NS 9321-F-20423 Text19:

3-MST-128-B 1

S MST-49 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20423 Text19:

3-MST-129-A 1

S Main Steam to MST-50 High quality main steam line.

PEPSE NS 9321-F-20423 Text19:

3-MST-129-B 1

S MST-50 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20423 Text19:

3-MST-130-A 1

S Main Steam to MST-51 High quality main steam line.

PEPSE NS 9321-F-20423 Text19:

3-MST-130-B 1

S MST-51 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20423 Text19:

3-MST-131-A 1

S Main Steam to MST-52 High quality main steam line.

PEPSE NS 9321-F-20423 Text19:

3-MST-131-B 1

S MST-52 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20423 Text19:

3-MST-132-B 1

S MST-56 to Steam Trap Header Operating conditions unknown.

PEPSE NC 9321-F-20423 Text19:

3-MST-133-B 1

S MST-57 to Steam Trap Header Operating conditions unknown.

PEPSE NC 9321-F-20423 Text19:

3-MST-134-B 1

S MST-58 to Steam Trap Header Operating conditions unknown.

PEPSE NC 9321-F-20423 Text19:

3-MST-135-B 1

S MST-59 to Steam Trap Header Operating conditions unknown.

PEPSE NC 9321-F-20423 Text19:

3-MST-136-A 1

S Steam to MST-60 Operating conditions unknown.

PEPSE NC 9321-F-20423 Text19:

3-MST-136-B 1

S MST-60 to Header Operating conditions unknown.

PEPSE NC 9321-F-20423 Text19:

3-MST-137-A 1

S Steam to MST-61 Operating conditions unknown.

PEPSE NC 9321-F-20423 Text19:

3-MST-137-B 1

S MST-61 to Steam Trap Header Operating conditions unknown.

PEPSE NC 9321-F-20423 Text19:

3-MST-138-A 1

S Steam to MST-62 Operating conditions unknown.

PEPSE NC 9321-F-20423 Text19:

3-MST-138-B 1

S MST-62 to Steam Trap Header Operating conditions unknown.

PEPSE NC 9321-F-20423 Text19:

3-MST-139-A 1

S Steam to MST-63 Operating conditions unknown.

PEPSE NC 9321-F-20423 Text19:

3-MST-139-B 1

S MST-63 to Steam Trap Header Operating conditions unknown.

PEPSE NC 9321-F-20423 Report No. 0700.104-17, Appendix C, Revision 2 Page C-84 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Steam Traps (MST), Unit 3 Section B: SNM Program Lines 3-MST-01: Main Steam lines surrounding Main Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-MST-140-A 1

S Steam to MST-64 High quality main steam line.

PEPSE NS 9321-F-20413 Text19:

3-MST-140-B 1

S MST-64 to Header Operating conditions unknown.

P&ID NS 9321-F-20413 Text19:

3-MST-140-D 1

S Header to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20413 Text19:

3-MST-141-A 1

S Steam to MST-65 Operating conditions unknown.

PEPSE NS 9321-F-20413 Text19:

3-MST-141-B 1

S MST-65 to Header Operating conditions unknown.

P&ID NS 9321-F-20413 Text19:

3-MST-143-A 1

S Steam to MST-80 High quality main steam line.

PEPSE NS 9321-F-20423 Text19:

3-MST-143-B 1

S MSt-80 to Steam Trap Header Operating conditions unknown.

P&ID NS 9321-F-20423 Text19:

3-MST-163-A 0.75 S

Main Steam to MST-70 High quality main steam line.

PEPSE NQ 9321-F-41573 Text19:

3-MST-163-B 0.75 S

MST-70 to Steam Trap Header Unknown conditions in line PEPSE NS 9321-F-41573 Section C: Excluded Lines 3-MST-01: Main Steam lines surrounding Main Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-MST-085-C E

MST-1 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20413 Text19:

3-MST-086-C E

MST-2 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20413 Text19:

3-MST-087-C E

MST-3 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20413 Text19:

3-MST-088-D E

MST-4 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20413 Text19:

3-MST-089-C E

MST-5 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20413 Text19:

3-MST-090-C E

MST-6 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20413 Text19:

3-MST-091-C E

MST-8 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20413 Report No. 0700.104-17, Appendix C, Revision 2 Page C-85 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Steam Traps (MST), Unit 3 Section C: Excluded Lines 3-MST-01: Main Steam lines surrounding Main Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-MST-092-C E

MST-9 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20413 Text19:

3-MST-093-C E

MST-10 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20413 Text19:

3-MST-094-C E

MST-12 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20413 Text19:

3-MST-095-C E

MST-13 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20413 Text19:

3-MST-096-C E

MST-14 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20413 Text19:

3-MST-097-C E

MST-16 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20413 Text19:

3-MST-098-C E

MST-18 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20413 Text19:

3-MST-099-C E

MST-20 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20413 Text19:

3-MST-100-C E

MST-21 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20413 Text19:

3-MST-101-C E

MST-22 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20413 Text19:

3-MST-102-C E

MST-23 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20413 Text19:

3-MST-103-C E

MST-24 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20413 Text19:

3-MST-104-C E

MST-25 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20413 Text19:

3-MST-105-C E

MST-26 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-106-C E

MST-27 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20413 Text19:

3-MST-107-C E

MST-28 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-108-C E

MST-29 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-109-C E

MST-30 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-110-C E

MST-31 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-111-C E

MST-32 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Report No. 0700.104-17, Appendix C, Revision 2 Page C-86 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Steam Traps (MST), Unit 3 Section C: Excluded Lines 3-MST-01: Main Steam lines surrounding Main Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-MST-112-A 1

E Steam to MST-33 Line only operates during startup P&ID EI 9321-F-20423 Text19:

3-MST-112-C E

MST-33 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-113-C E

MST-34 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-114-C E

MST-35 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-115-C E

MST-36 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20413 Text19:

3-MST-116-C E

MST-37 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-117-C E

MST-38 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-118-C E

MST-39 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-119-C E

MST-40 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-120-C E

MST-41 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20413 Text19:

3-MST-121-C E

MST-42 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-122-C E

MST-43 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-123-C E

MST-44 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-124-C E

MST-45 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-125-C E

MST-46 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-126-C E

MST-47 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-127-C E

MST-48 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-128-C E

MST-49 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-129-C E

MST-50 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-130-C E

MST-51 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Report No. 0700.104-17, Appendix C, Revision 2 Page C-87 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Steam Traps (MST), Unit 3 Section C: Excluded Lines 3-MST-01: Main Steam lines surrounding Main Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-MST-131-C E

MST-52 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-132-A 1

E Steam to MST-56 Line only operates during startup P&ID EI 9321-F-20423 Text19:

3-MST-132-C E

MST-56 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-133-A 1

E Steam to MST-57 Line only operates during startup P&ID EI 9321-F-20423 Text19:

3-MST-133-C E

MST-57 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-134-A 1

E Steam to MST-58 Line only operates during startup P&ID EI 9321-F-20423 Text19:

3-MST-134-C E

MST-58 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-135-A 1

E Steam to MST-59 Line only operates during startup P&ID EI 9321-F-20423 Text19:

3-MST-135-C E

MST-59 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-136-C E

MST-60 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-137-C E

MST-61 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-138-C E

MST-62 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-139-C E

MST-63 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-140-C E

MST-64 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20413 Text19:

3-MST-141-C E

MST-65 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20413 Text19:

3-MST-142-A 0.75 E

Steam to MST-79 Valve shown closed on P&ID.

P&ID EI 9321-F-20413 Text19:

3-MST-142-B 0.75 E

MST-79 to Condenser No 33 Valve shown closed on P&ID.

P&ID EI 9321-F-20413 Text19:

3-MST-142-C E

MST-79 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20413 Text19:

3-MST-143-C E

MST-80 Bypass Line Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Text19:

3-MST-165 0.75 E

MST-70 Bypass via MS-266 Valve shown closed on P&ID.

P&ID EI 9321-F-41573 Report No. 0700.104-17, Appendix C, Revision 2 Page C-88 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Main Steam Traps (MST), Unit 3 Section C: Excluded Lines 3-MST-01: Main Steam lines surrounding Main Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-MST-166 3

E Main Steam Trap Header Replaced with Chrome-moly IP3-RPT-MULT-03162, Rev.

3, Appendix B EM 9321-F-20413, 9321-F-20423 Text19:

3-MST-167 4

E Main Steam Trap Header to connection with 3-MST-169 Replaced with Chrome-moly IP3-RPT-MULT-03162, Rev.

3, Appendix B EM 9321-F-20423 Text19:

3-MST-168 2

E Main Steam Traps Header to Main Header Replaced with Chrome-moly TS-MS-024 Addendum D EM 9321-F-20423 Text19:

3-MST-169 2

E Main Steam Traps Main Header to Drains Collecting Tank Replaced with Chrome-moly TS-MS-024 Addendum D EM 9321-F-20423 Text19:

3-MST-170 4

E Main Steam Traps Main Header Drain to Discharge Tunnel Valve shown closed on P&ID.

P&ID EI 9321-F-20423 Report No. 0700.104-17, Appendix C, Revision 2 Page C-89 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Moisture Preseparator Drains (PD), Unit 3 Section A: CHECWORKS Model Lines 3-PD-01: Moisture Preseparator Lines Line Number Size (in.)

Sus.

Cat.

Comments Reference P&ID No.

Line Description Text19:

3-PD-032 10 M

PD-01.1 PRESEP 1B DR to HDR:

Moisture Preseparator 1B to Separation Chamber header PEPSE 9321-F-20223 Sheet 1 Text19:

3-PD-033 10 M

PD-01.3 PRESEP 1A DR to HDR:

Moisture Preseparator 1A to Separation Chamber header PEPSE 9321-F-20223 Sheet 1 Text19:

3-PD-034 10 M

PD-01.5 PRESEP 2B DR to HDR:

Moisture Preseparator 2B to Separation Chamber header PEPSE 9321-F-20223 Sheet 1 Text19:

3-PD-035 10 M

PD-01.7 PRESEP 2A DR to HDR:

Moisture Preseparator 2A to Separation Chamber header PEPSE 9321-F-20223 Sheet 1 Text19:

3-PD-036 16 M

PD-02.2 PRESEP HDR to HD TK:

1A and 1B MPS to Separation Chamber PEPSE 9321-F-20223 Sheet 1 Text19:

3-PD-037 16 M

PD-02.3 PRESEP HDR to HD TK:

1A, 1B, and 2A MPS to Separation Chamber PEPSE 9321-F-20223 Sheet 1 Text19:

3-PD-038 16 M

PD-02.4 PRESEP HDR to HD TK:

Moisture Preseparators to Separation Chamber PEPSE 9321-F-20223 Sheet 1 Text19:

3-PD-040 16 M

PD-02.4 PRESEP HDR to HD TK:

Separation Chamber to Loop Seal PEPSE 9321-F-20223 Sheet 1 Report No. 0700.104-17, Appendix C, Revision 2 Page C-90 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Moisture Preseparator Drains (PD), Unit 3 Section C: Excluded Lines 3-PD-01: Moisture Preseparator Lines Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-PD-039 3

E Separation Chamber vent to HDT vent line to FWH 35A Line was constructed with Chrome-Moly IP3-RPT-MULT-03162, Rev.

3, Appendix B EM 9321-F-20223 Sheet 1 Text19:

3-PD-041 16 E

PD-02.4 PRESEP HDR to HD TK:

Loop Seal to Heater Drain Tank Valve shown closed on P&ID.

P&ID EI 9321-F-20223 Sheet 1 Text19:

3-PD-042 1

E Vent from Loop Seal to Heater Drain Tank Line operates less than 2% of the time P&ID EI 9321-F-20223 Sheet 1 Report No. 0700.104-17, Appendix C, Revision 2 Page C-91 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Reheat Steam Traps (RST), Unit 3 Section B: SNM Program Lines 3-RST-02: Reheat Steam from Steam Traps to Boiler Feed Pump Turbine Drip Tank Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-RST-001 0.75 S

RST-1 to BFP Turbine Drip Tank Header Operating conditions unknown.

P&ID NC 9321-F-20243 Text19:

3-RST-002 0.75 S

RST-2 to BFP Turbine Drip Tank Header Operating conditions unknown.

P&ID NC 9321-F-20243 Text19:

3-RST-003 0.75 S

RST-3 to BFP Turbine Drip Tank Header Operating conditions unknown.

P&ID NC 9321-F-20243 Text19:

3-RST-004 2

S Reheat Steam Trap Header to BFP Turbine Drip Tank Operating conditions unknown.

P&ID NC 9321-F-20243 Report No. 0700.104-17, Appendix C, Revision 2 Page C-92 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Service Boiler (SB), Unit 3 Section B: SNM Program Lines 3-SB-02: Service Boiler Lines Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-SB-002 10 S

Main Steam Header to Aux Steam line Operating conditions unknown.

P&ID NC 9321-F-41283 Text19:

3-SB-003 10 S

Main Steam Header to Aux Steam line Operating conditions unknown.

P&ID NC 9321-F-41283 Text19:

3-SB-004 10 S

Aux Steam to Desuperheater Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-SB-006 6

S Steam from Steam Drum towards Desuperheater Operating conditions unknown.

P&ID NC 9321-F-41283 Text19:

3-SB-008 3

S Aux Steam to Condenser Water Box Lifting Jets Air Ejectors and Seal Steam Header Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-SB-016 1

S Aux Steam Traps AST26 and AST-3 to Cond Receiver Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-SB-017 4

S Aux Steam header to Condenser Water Box Lifting Jets Air Ejectors Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-SB-018 3

S Header to Air Ejector # 31 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-SB-019 3

S Header to Air Ejector # 32 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-SB-020 2.5 S

Header to AST-5 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-SB-021 1

S AST-5 to Cond Receiver Header Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-SB-023 10 S

Desuperheater to Air Purge Heating Coils Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-SB-032 0.75 S

Steam Drum drain to House Service Boiler Blowdown tank Operating conditions unknown.

P&ID NC 9321-F-41283 Text19:

3-SB-037 8

S Steam Drum header to Deaerator, Aux Steam Supply, and Steam Trap assembly Operating conditions unknown.

P&ID NC 9321-F-41283 Report No. 0700.104-17, Appendix C, Revision 2 Page C-93 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Service Boiler (SB), Unit 3 Section B: SNM Program Lines 3-SB-02: Service Boiler Lines Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-SB-038 3

S Steam Drum to Deaerator Operating conditions unknown.

P&ID NC 9321-F-41283, 9321-F-41293 Text19:

3-SB-039 8

S Steam Drum to Aux Steam Supply Operating conditions unknown.

P&ID NC 9321-F-41283 Text19:

3-SB-052 4

S Aux Steam to Aux Boiler Building Operating conditions unknown.

P&ID NC 9321-F-41283, 9321-F-41563 Text19:

3-SB-053 1

S Aux Steam to Aux Boiler Building through PCV 101 Operating conditions unknown.

P&ID NC 9321-F-41283 Text19:

3-SB-055 4

S Upper Boiler Room Steam header to various equipment Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-SB-056 2.5 S

Aux Steam header to Unit Heaters 1 and 2 Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-SB-057 2

S Aux Steam to HSB-UH 1 thru TCV 221 Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-SB-058 1

S Aux Steam to HSB-UH 2 thru TCV 222 Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-SB-065 0.75 S

Aux Steam to HSB-UH 3 thru TCV 223 Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-SB-068 0.75 S

Aux Steam to HSB-UH 4 thru TCV 224 Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-SB-072 1.5 S

Aux Steam header to various Unit Heaters Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-SB-073 1

S Aux Steam header to Unit Heaters 5-7 Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-SB-074 0.75 S

Aux Steam to HSB-UH 5 Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-SB-075 0.75 S

Aux Steam to HSB-UH 6 Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-SB-076 0.75 S

Aux Steam to HSB-UH 7 Operating conditions unknown.

P&ID NC 9321-F-41563 Report No. 0700.104-17, Appendix C, Revision 2 Page C-94 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Service Boiler (SB), Unit 3 Section B: SNM Program Lines 3-SB-02: Service Boiler Lines Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-SB-077 1.5 S

Aux Steam to HSB-UH 16 Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-SB-078 0.75 S

Aux Steam to HSB-UH 17 Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-SB-090 1

S Aux Steam header to Unit Heater 8, 9, and 10 Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-SB-091 0.75 S

Aux Steam to HSB-UH 8 Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-SB-092 0.75 S

Aux Steam to HSB-UH 9 Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-SB-093 0.75 S

Aux Steam to HSB-UH 10 Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-SB-101 1.25 S

Aux Steam to HSB-UH 11, and 13, 15, and 18 Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-SB-102 0.75 S

Aux Steam to HSB-UH 11 Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-SB-103 1.25 S

Aux Steam header to Unit Heaters Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-SB-104 1

S Aux Steam header to Unit Heaters 13, 15, and 18 Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-SB-105 1

S Aux Steam to HSB-UH 14 Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-SB-106 0.75 S

Aux Steam to HSB-UH 13 Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-SB-107 0.75 S

Aux Steam to HSB-UH 18 Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-SB-108 0.75 S

Aux Steam to HSB-UH 15 Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-SB-109 0.75 S

Unit heater Bypass to Condensate Return Tank header Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-SB-116 1.5 S

Condensate Return Tank header Operating conditions unknown.

P&ID NC 9321-F-41563, 9321-F-41293 Text19:

3-SB-122 3

S Aux Steam to HSB-HC 1A and 1B Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-SB-123 2.5 S

Aux Steam to HSB-HC 1A Operating conditions unknown.

P&ID NC 9321-F-41563 Report No. 0700.104-17, Appendix C, Revision 2 Page C-95 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Service Boiler (SB), Unit 3 Section B: SNM Program Lines 3-SB-02: Service Boiler Lines Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-SB-124 2.5 S

Aux Steam to HSB-HC 1B Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-SB-127 2

S HSB-HC return header to Condensate Return Tank Operating conditions unknown.

P&ID NC 9321-F-41563, 9321-F-41293 Text19:

3-SB-131 1.5 S

HSB-UH return to Condensate Receiver Operating conditions unknown.

P&ID NC 9321-F-41563, 9321-F-42083 Text19:

3-UHT-050 0.75 S

Steam Trap "D" to Condensate Receiver Operating conditions unknown.

P&ID NC 9321-F-41283 Text19:

3-UHT-050-A 0.75 S

Steam Trap "D" to Condensate Receiver Operating conditions unknown.

P&ID NC 9321-F-41283 Section C: Excluded Lines 3-SB-02: Service Boiler Lines Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-SB-001 3

E Auxiliary Steam from PCV-1257 Due to pressure drop across PCV 1257 this line is superheated P&ID EQ 9321-F-41573, 9321-F-40573, 9321-F-41283 Text19:

3-SB-009 4

E Aux Steam to Seal Steam Header Valve shown closed on P&ID.

P&ID EI 9321-F-40573, 9321-F-20173 Text19:

3-SB-022 1

E AST-5 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-40573 Text19:

3-SB-024 0.75 E

Steam Drum drain to header Valve shown closed on P&ID.

P&ID EI 9321-F-41283 Text19:

3-SB-025 0.75 E

Steam Drum drain to header Valve shown closed on P&ID.

P&ID EI 9321-F-41283 Text19:

3-SB-026 1

E Steam drum drain header to Service Boiler Blowdown tank Valve shown closed on P&ID.

P&ID EI 9321-F-41283 Text19:

3-SB-027 1

E Steam Drum drain back to Deaerator thru Steam Trap SBBD-T-1 Valve shown closed on P&ID.

P&ID EI 9321-F-41283 Report No. 0700.104-17, Appendix C, Revision 2 Page C-96 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Service Boiler (SB), Unit 3 Section C: Excluded Lines 3-SB-02: Service Boiler Lines Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-SB-028 1

E Steam drain drum to Deaerator header Valve shown closed on P&ID.

P&ID EI 9321-F-41283 Text19:

3-SB-029 1

E Steam drain drum to Deaerator header Valve shown closed on P&ID.

P&ID EI 9321-F-41283 Text19:

3-SB-030 3

E Drain header from Steam Drum to Deaerator Valve shown closed on P&ID.

P&ID EI 9321-F-41283, 9321-F-41293 Text19:

3-SB-031 0.75 E

Steam Trap SBBD-T-1 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41283 Text19:

3-SB-033 8

E Steam Drum vent to roof Low to no flow in vent to atmosphere P&ID EF 9321-F-41283 Text19:

3-SB-034 8

E Steam Drum vent to roof Low to no flow in vent to atmosphere P&ID EF 9321-F-41283 Text19:

3-SB-035 0.75 E

Steam drum vent to roof drain Low to no flow in line P&ID EF 9321-F-41283 Text19:

3-SB-036 0.75 E

Steam drum vent to roof drain Low to no flow in line P&ID EF 9321-F-41283 Text19:

3-SB-040 2

E PCV 109 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41293 Text19:

3-SB-043 1

E Valve SB-64 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41283 Text19:

3-SB-044 1

E Valve SB-65 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41283 Text19:

3-SB-047 8

E House Service Boiler Blowdown Tank vent to the roof Low to no flow in vent to atmosphere P&ID EF 9321-F-41283 Text19:

3-SB-048 3

E House Service Boiler Blowdown Tank drain to pit Low to no flow in line P&ID EF 9321-F-41283 Text19:

3-SB-049 1

E HSBB Tank vent to roof drain to pit Low to no flow in line P&ID EF 9321-F-41283 Text19:

3-SB-054 4

E Aux Steam to Aux Boiler Building bypassing PCV 1152 Valve shown closed on P&ID.

P&ID EI 9321-F-41283 Text19:

3-SB-059 2

E TCV 221 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41563 Text19:

3-SB-128 2.5 E

TCV 27 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41563 Report No. 0700.104-17, Appendix C, Revision 2 Page C-97 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Service Boiler (SB), Unit 3 Section C: Excluded Lines 3-SB-02: Service Boiler Lines Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-SB-132 1

E Condensate Pump 21 Suction from Condensate Receiver Temperature of condensate leaving Condensate receiver is below 200 degF P&ID ET 9321-F-41563 Text19:

3-SB-133 1

E Condensate Pump 22 Suction from Condensate Receiver Temperature of condensate leaving Condensate receiver is below 200 degF P&ID ET 9321-F-41563 Text19:

3-SB-134 1

E Condensate Pump 21 to Condensate Return Tank header Temperature of condensate leaving Condensate receiver is below 200 degF P&ID ET 9321-F-41563 Text19:

3-SB-135 1

E Condensate Pump 22 to Condensate Return Tank header Temperature of condensate leaving Condensate receiver is below 200 degF P&ID ET 9321-F-41563 Text19:

3-UHT-051 0.75 E

Steam Trap "D" Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41283 Text19:

3-UHT-051-A 0.75 E

Steam Trap "D" Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41283 Report No. 0700.104-17, Appendix C, Revision 2 Page C-98 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Service Boiler Feed Pump (SBF), Unit 3 Section B: SNM Program Lines 3-SBF-01: Service Boiler lines from Deaerator to Steam Drum thru Service Boiler Feed Pumps Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-SBF-006 1

S Service Boiler Feed Pump 31 Low Flow Recirc line Operating conditions unknown.

P&ID NC 9321-F-41293 Text19:

3-SBF-007 1

S Service Boiler Feed Pump 32 Low Flow Recirc line Operating conditions unknown.

P&ID NC 9321-F-41293 Section C: Excluded Lines 3-SBF-01: Service Boiler lines from Deaerator to Steam Drum thru Service Boiler Feed Pumps Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-SBF-001 6

E Deaerator to Service Boiler Feed Pumps Suction header Temperature does not exceed 200 degF PEPSE ET 9321-F-41293 Text19:

3-SBF-002 4

E Suction for Service Boiler Feed Pump 31 Temperature does not exceed 200 degF PEPSE ET 9321-F-41293 Text19:

3-SBF-003 4

E Suction for Service Boiler Feed Pump 32 Temperature does not exceed 200 degF PEPSE ET 9321-F-41293 Text19:

3-SBF-004 4

E Service Boiler Feed Pump 31 to header Temperature does not exceed 200 degF PEPSE ET 9321-F-41293 Text19:

3-SBF-005 4

E Service Boiler Feed Pump 32 to header Temperature does not exceed 200 degF PEPSE ET 9321-F-41293 Text19:

3-SBF-008 4

E Service Boiler Feed Pumps header to Steam Drum Temperature does not exceed 200 degF PEPSE ET 9321-F-41293, 9321-F-41283 Text19:

3-SBF-009 1

E Deaerator Recirc line Valve shown closed on P&ID.

P&ID EI 9321-F-41293 Text19:

3-SBF-010 3

E LCV 2031 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41283 Text19:

3-SBF-011 0.75 E

Boiler Feed Pump drain to Service Boiler Blowdown Tank Valve shown closed on P&ID.

P&ID EI 9321-F-41283 Report No. 0700.104-17, Appendix C, Revision 2 Page C-99 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Return Unit Heaters to Service Boiler D (UH), Unit 3 Section B: SNM Program Lines 3-UH-01: Auxiliary Steam Lines to Various Equipment Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-UH-001 10 S

Aux Steam to Air Purge Heating Coils Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UH-003 0.75 S

AST-30 to Cond. Receiver Header Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UH-005 2.5 S

Header to Dirty and Clean oil Tanks Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UH-006 2

S Aux Steam to Dirty and Clean Oil Tanks Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UH-008 2

S Aux Steam to Oil Tanks through PCV 1291 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UH-009 2

S PCV 1291 Bypass Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UH-010 2

S Header to Oil Tanks Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UH-011 2

S Aux Steam to Dirty Oil Tank Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UH-012 2

S Aux Steam to Clean Oil Tank Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UH-015 1.5 S

header from Oil tanks to waste drain Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UH-018 8

S Desuperheater outlet header to various unit heaters Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UH-060 2

S Unit Heater header to Cond Receiver Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UH-061 4

S Unit Heater header to Cond Receiver Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UH-062 2

S Unit Heater header to Cond Receiver Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UH-063 2

S Unit Heater header to Cond Receiver Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UH-076 10 S

Aux Steam header to Air Purge heating Coils and Air Temp Units Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UH-077 6

S Aux Steam header to Air Purge heating Coils and Air Temp Units Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UH-078 4

S Header to Air Purge Heating Coils Operating conditions unknown.

P&ID NC 9321-F-40573 Report No. 0700.104-17, Appendix C, Revision 2 Page C-100 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Return Unit Heaters to Service Boiler D (UH), Unit 3 Section B: SNM Program Lines 3-UH-01: Auxiliary Steam Lines to Various Equipment Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-UH-079 2

S Aux Steam through valve UH-129-1 to Air Purge heating Coil Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UH-080 2

S Aux Steam through valve UH-129-2 to Air Purge heating Coil Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UH-085 3

S Air Purge Heating Coil Unit Heater header to Cond Receiver Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UH-086 3

S Fuel Storage Building Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UH-087 3

S Aux Steam to Air Temp Unit # 32 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UH-088 3

S Aux Steam to Air Temp Unit # 31 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UH-089 1.5 S

Steam from Air Temp Unit #32 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UH-090 1.5 S

Steam from Air Temp Unit # 31 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UH-096 10 S

Aux Steam header to Primary Auxiliary building Operating conditions unknown.

P&ID NC 9321-F-40573, 9321-F-27273 Text19:

3-UH-098 2

S Aux Steam to and from UHT-563 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-102 1

S Aux Steam to and from UHT-2-4 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-103 1

S Aux Steam from Unit Heaters to Cond Receiver Header Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-106 6

S Aux Steam to various equipment Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-107 4

S Aux Steam header to Unit Heaters Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-108 4

S Aux Steam header to Unit Heaters and Water Storage Tanks Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-109 2

S Aux Steam to Unit heaters and Batching Mix Tank Operating conditions unknown.

P&ID NC 9321-F-27273 Report No. 0700.104-17, Appendix C, Revision 2 Page C-101 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Return Unit Heaters to Service Boiler D (UH), Unit 3 Section B: SNM Program Lines 3-UH-01: Auxiliary Steam Lines to Various Equipment Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-UH-110 3

S Aux Steam to Air Heating Coils Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-111 4

S Aux Steam to Air Temp Unit and Steam Heating Coils Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-112 6

S Aux Steam to Refueling Water Storage Tank Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-113 2

S Aux Steam header to Primary Water Storage Tank No. 31 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-114 4

S Aux Steam from Refueling Water Storage Tank Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-119 2

S Aux Steam to Batching Mix Tank Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-121 0.75 S

Aux Steam from Batching Mix Tank Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-148 1

S Aux Steam from Steam Traps to Cond Receiver Header Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-149 4

S Aux Steam header from Steam Traps to Cond Receiver Header Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-153 2

S Aux Steam to Air Temp Unit Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-155 3

S Aux Steam to Air Heating Coils thru valve UH 114-1 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-156 3

S Aux Steam to Air Heating Coils thru valve UH 114-2 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-157 3

S Aux Steam to Air Heating Coils thru valve UH 114-3 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-158 3

S Header to Air Heating Coils Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-159 2

S Aux Steam to Air Heating Coil 31 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-160 2

S Aux Steam to Air Heating Coil 32 Operating conditions unknown.

P&ID NC 9321-F-27273 Report No. 0700.104-17, Appendix C, Revision 2 Page C-102 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Return Unit Heaters to Service Boiler D (UH), Unit 3 Section B: SNM Program Lines 3-UH-01: Auxiliary Steam Lines to Various Equipment Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-UH-161 2

S Aux Steam to Air Heating Coil 33 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-162 0.75 S

Aux Steam thru UHT-731 to Air Heating Coil return lines Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-163 1.5 S

Aux Steam from Air Heating Coil 31 upstream of valve UH-723 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-164 1.5 S

Aux Steam from Air Heating Coil 32 upstream of valve UH-725 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-165 1.5 S

Aux Steam from Air Heating Coil 33 upstream of valve UH-727 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-169 0.5 S

Aux Steam thru Thermostatic Air Vent UH-126 to Condensate Receiver Pit Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-170 0.5 S

Aux Steam thru Thermostatic Air Vent UH-749 to Condensate Receiver Pit Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-171 0.5 S

Aux Steam thru Thermostatic Air Vent UH-750 to Condensate Receiver Pit Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-172 1.5 S

Header to Cond Receiver IP3V-138-0001 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-173 4

S Aux Steam to Steam Heating Coils in Radioactive Machine Shop Operating conditions unknown.

P&ID NC 9321-F-27273, 9321-F-41443 Text19:

3-UH-177 2

S Aux Steam Supply to Outage Support Building Operating conditions unknown.

P&ID NC 9321-F-40573, 9321-F-80793 Text19:

3-UH-178 1

S Condensate Return from Outage Support Building Operating conditions unknown.

P&ID NC 9321-F-80793, 9321-F-40573 Text19:

3-UH-183 6

S Aus Steam to Administration Service Building Operating conditions unknown.

P&ID NC 9321-F-40573, 9321-F-41553 Report No. 0700.104-17, Appendix C, Revision 2 Page C-103 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Return Unit Heaters to Service Boiler D (UH), Unit 3 Section B: SNM Program Lines 3-UH-01: Auxiliary Steam Lines to Various Equipment Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-UH-184 2.5 S

Aux Steam to Heat Exchanger and Steam Trap assembly Operating conditions unknown.

P&ID NC 9321-F-41553 Text19:

3-UH-185 4

S Aux Steam to Hot Water Heater and Steam Trap assembly Operating conditions unknown.

P&ID NC 9321-F-41553 Text19:

3-UH-186 1.5 S

Aux Steam to Humidifiers and steam trap assemblies Operating conditions unknown.

P&ID NC 9321-F-41553 Text19:

3-UH-187 6

S Aux Steam to Heat Exchanger AS HX-1 Operating conditions unknown.

P&ID NC 9321-F-41553 Text19:

3-UH-190 2

S Aux Steam to Heat Exchanger AS HX-2 Operating conditions unknown.

P&ID NC 9321-F-41553 Text19:

3-UH-192 1.5 S

Aux Steam to Humidifier AS HU-1 Operating conditions unknown.

P&ID NC 9321-F-41553 Text19:

3-UH-194 1.5 S

Aux Steam to Humidifier AS HU-2 Operating conditions unknown.

P&ID NC 9321-F-41553 Text19:

3-UH-196 4

S Aux Steam to Hot Water Heater Operating conditions unknown.

P&ID NC 9321-F-41553 Text19:

3-UH-211 4

S Header to Cond Receiver Operating conditions unknown.

P&ID NC 9321-F-41553 Text19:

3-UH-220 1

S Condensate Transfer Pump 31 Low Flow Recirc line Operating conditions unknown.

P&ID NC 9321-F-41293 Text19:

3-UH-221 1

S Condensate Transfer Pump 32 Low Flow Recirc line Operating conditions unknown.

P&ID NC 9321-F-41293 Text19:

3-UH-236 2

S Aux Steam from Refueling Water Storage Tank to Cond. Receiver Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UH-237 2.5 S

Unit Heater header to Cond Receiver Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UH-238 2.5 S

Unit Heater header to Cond Receiver Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UH-239 3

S Aux Steam from Deaerator Overflow Trap to House Service Boiler Aux Steam from Steam Trap UH-T-303 dumps into this line making it susceptible P&ID NC 9321-F-41293 Report No. 0700.104-17, Appendix C, Revision 2 Page C-104 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Return Unit Heaters to Service Boiler D (UH), Unit 3 Section C: Excluded Lines 3-UH-01: Auxiliary Steam Lines to Various Equipment Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-UH-017 1

E Drain to Trench Low to no flow in line P&ID EF 9321-F-40573 Text19:

3-UH-019 10 E

Aux Steam vent to atmosphere Low to no flow in line P&ID EF 9321-F-40573 Text19:

3-UH-020 1

E Aux Steam drain to waste Low to no flow in line P&ID EF 9321-F-40573 Text19:

3-UH-116 4

E TCV-1116 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-27273 Text19:

3-UH-117 1.5 E

TCV-1115 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-27273 Text19:

3-UH-118 4

E PCV-1250 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-27273 Text19:

3-UH-120 2

E PCV-1251 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-27273 Text19:

3-UH-150 0.5 E

Cond Receiver IP3V-138-0002 to Cond Receiver IP3V-138-0001 thru Pump 33A Temperature in line does not exceed 200 degF PEPSE ET 9321-F-27273 Text19:

3-UH-151 0.5 E

Cond Receiver IP3V-138-0002 to Cond Receiver IP3V-138-0001 thru Pump 33B Temperature in line does not exceed 200 degF PEPSE ET 9321-F-27273 Text19:

3-UH-152 1.5 E

Header to Cond Receiver IP3V-138-0001 Temperature in line does not exceed 200 degF PEPSE ET 9321-F-27273 Text19:

3-UH-154 2

E Aux Steam return from Air Temp Unit Valve shown closed on P&ID.

P&ID EI 9321-F-27273 Text19:

3-UH-175 3

E Cond Receiver to House Service Boiler Cond Receiver Tank Temperature in line does not exceed 200 degF PEPSE ET 9321-F-27273, 9321-F-40573 Text19:

3-UH-176 0.5 E

Aux Steam to Radiation Monitor Temperature in line does not exceed 200 degF PEPSE ET 9321-F-27273 Text19:

3-UH-179 6

E Cond Receiver to House Service Boiler Condensate Return Tank Temperature does not exceed 200 degF PEPSE ET 9321-F-40573 Text19:

3-UH-180 3

E Cond Receiver to House Service Boiler Condensate Return Tank through pump 32 Temperature does not exceed 200 degF PEPSE ET 9321-F-40573 Report No. 0700.104-17, Appendix C, Revision 2 Page C-105 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Return Unit Heaters to Service Boiler D (UH), Unit 3 Section C: Excluded Lines 3-UH-01: Auxiliary Steam Lines to Various Equipment Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-UH-181 3

E Cond Receiver to House Service Boiler Condensate Return Tank through pump 31 Temperature does not exceed 200 degF PEPSE ET 9321-F-40573 Text19:

3-UH-182 4

E Header to House Service Boiler Condensate Return Tank Temperature does not exceed 200 degF PEPSE ET 9321-F-40573, 9321-F-41293 Text19:

3-UH-203 1.25 E

PCV 2052 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41553 Text19:

3-UH-204 1.5 E

TCV 1206 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41553 Text19:

3-UH-205 3

E TCV 675 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41553 Text19:

3-UH-208 4

E TCV 1300 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41553 Text19:

3-UH-212 2

E Cond Receiver Vent Low to no flow in line PEPSE EF 9321-F-41553 Text19:

3-UH-213 2.5 E

Cond Receiver to House Service Boiler Condensate Return Tank Temperature does not exceed 200 degF PEPSE ET 9321-F-41553 Text19:

3-UH-214 2.5 E

Cond Receiver to House Service Boiler Condensate Return Tank Temperature does not exceed 200 degF PEPSE ET 9321-F-41553 Text19:

3-UH-215 2.5 E

Cond Receiver header to House Service Boiler Condensate Return Tank Temperature does not exceed 200 degF PEPSE ET 9321-F-41553, 9321-F-41293 Text19:

3-UH-216 6

E Service Boiler Condensate Transfer Pump 31 Suction Temperature does not exceed 200 degF PEPSE ET 9321-F-41293 Text19:

3-UH-217 6

E Service Boiler Condensate Transfer Pump 32 Suction Temperature does not exceed 200 degF PEPSE ET 9321-F-41293 Text19:

3-UH-218 4

E Condensate Transfer Pump 31 to Deaerator header Temperature does not exceed 200 degF PEPSE ET 9321-F-41293 Text19:

3-UH-219 4

E Condensate Transfer Pump 32 to Deaerator header Temperature does not exceed 200 degF PEPSE ET 9321-F-41293 Report No. 0700.104-17, Appendix C, Revision 2 Page C-106 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Return Unit Heaters to Service Boiler D (UH), Unit 3 Section C: Excluded Lines 3-UH-01: Auxiliary Steam Lines to Various Equipment Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-UH-222 4

E Condensate Transfer Pump header to deaerator Temperature does not exceed 200 degF PEPSE ET 9321-F-41293 Text19:

3-UH-223 3

E Service Boiler overflow drain Low to no flow in line P&ID EF 9321-F-41293 Text19:

3-UH-224 2

E Service Boiler drain Valve shown closed on P&ID.

P&ID EI 9321-F-41293 Text19:

3-UH-225 2

E Service Boiler drain Valve shown closed on P&ID.

P&ID EI 9321-F-41293 Text19:

3-UH-226 3

E Service Boiler vent to roof Low to no flow in line P&ID EF 9321-F-41293 Text19:

3-UH-227 2.5 E

Valve UH-319 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41293 Text19:

3-UH-230 4

E Deaerator vent to roof/drain Low to no flow in line P&ID EF 9321-F-41293 Text19:

3-UH-231 1

E Deaerator vent to roof Low to no flow in line P&ID EF 9321-F-41293 Text19:

3-UH-232 1

E Deaerator vent to roof - orifice bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41293 Text19:

3-UH-233 4

E Deaerator overflow drain to Service Boiler Condensate Return Tank Infrequent use of overflow line P&ID EI 9321-F-41293 Text19:

3-UH-234 0.38 E

Deaerator overflow trap return to deaerator Replaced with Chrome-moly IP3-RPT-MULT-03162 EM 9321-F-41293 Text19:

3-UH-235 1

E Air Heating Coils to Condensate Receiver Pit Piping is copper P&ID EM 9321-F-27273 Report No. 0700.104-17, Appendix C, Revision 2 Page C-107 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Return Unit Heater Steam Traps (UHT), Unit 3 Section B: SNM Program Lines 3-UHT-01: Auxiliary Steam to Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-UHT-007-A 1

S Aux Steam to trap UH-T-2-19 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-007-B 1

S Trap UH-T-2-19 to Cond. Receiver Header Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-008 1.5 S

Aux Steam thru Steam Trap and valve UH-469 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-41443 Text19:

3-UHT-009 0.75 S

Aux Steam thru Steam Trap UH-T-408-5 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-41443 Text19:

3-UHT-010 0.75 S

Aux Steam thru Steam Trap UH-T-409-5 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-41443 Text19:

3-UHT-011 0.75 S

Aux Steam thru Steam Trap UH-T-408-4 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-41443 Text19:

3-UHT-012 1

S Aux Steam thru Steam Trap UH-T-408-6 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-41443 Text19:

3-UHT-013 0.75 S

Aux Steam thru Steam Trap UH-T-408-9 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-41443 Text19:

3-UHT-013-A 0.75 S

Clean Oil Tank drain to trap UH-T 28 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-013-B 0.75 S

Trap UH-T-1-28 to waste header Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-014 0.75 S

Aux Steam thru Steam Trap UH-T-408-7 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-41443 Text19:

3-UHT-014-A 0.75 S

Dirty Oil drain to trap UH-T-1-29 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-014-B 0.75 S

Trap UH-T-1-29 to waste header Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-015 0.75 S

Aux Steam thru Steam Trap UH-T-408-8 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-41443 Report No. 0700.104-17, Appendix C, Revision 2 Page C-108 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Return Unit Heater Steam Traps (UHT), Unit 3 Section B: SNM Program Lines 3-UHT-01: Auxiliary Steam to Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-UHT-016 0.75 S

Aux Steam thru Steam Trap UH-T-408-2 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-41443 Text19:

3-UHT-016-A 1

S Aux Steam to trap UH-T-2-18 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-016-B 1

S Trap UH-T-2-18 to Cond. Receiver Header Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-017 0.75 S

Aux Steam thru Steam Trap UH-T-407-2 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-41443 Text19:

3-UHT-018 1

S Aux Steam from RS-UH-1 thru steam trap UH-T-397 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-41443 Text19:

3-UHT-019 1

S Aux Steam from RS-HC-2 thru steam trap UH-T-409-2 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-41443 Text19:

3-UHT-020 1.25 S

Aux Steam from RS-HC-4 thru steam trap UH-T-409-4 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-41443 Text19:

3-UHT-021 1

S Aux Steam to and from UH-T-589 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-021-A 1.25 S

Aux Steam from RS-HC-3 thru steam trap UH-T-409-3 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-41443 Text19:

3-UHT-022 1

S Aux Steam to and from UH-T-1-1 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-022-A 1.25 S

Aux Steam from RS-HC-1 thru steam trap UH-T-409-1 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-41443 Text19:

3-UHT-023 1

S Aux Steam to and from UH-T-1-2 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-023-A 0.75 S

Aux Steam from RS-HX-1 thru steam trap UH-T-408-3 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-41443 Report No. 0700.104-17, Appendix C, Revision 2 Page C-109 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Return Unit Heater Steam Traps (UHT), Unit 3 Section B: SNM Program Lines 3-UHT-01: Auxiliary Steam to Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-UHT-024 1

S Aux Steam to and from UH-T-1-3 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-025 1

S Aux Steam to and from UH-T-1-4 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-026 1

S Aux Steam to and from UH-T-1-5 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-027 1

S Aux Steam to and from UH-T-2-17 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-028 1

S Aux Steam to and from UH-T-1-25 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-029 1

S Aux Steam to and from UH-T-1-26 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-030 1

S Aux Steam to and from UH-T-1-27 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-031 1

S Aux Steam to and from UH-T-1-24 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-032 1

S Aux Steam to and from UH-T-1-22 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-033 1

S Aux Steam to and from UH-T-1-23 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-034 1

S Aux Steam to and from UH-T-2-28 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-035 1

S Aux Steam to and from UH-T-1-21 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-036 1

S Aux Steam to and from UH-T-1-20 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-037 1

S Aux Steam to and from UH-T-2-27 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-038 1

S Aux Steam to and from UH-T-1-19 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-039 1

S Aux Steam to and from UH-T-1-18 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-040 1

S Aux Steam to and from UH-T-2-25 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-041 1

S Aux Steam to and from UH-T-1-17 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-041-A 1

S Aux Steam thru Steam Trap UH-T-26 to Deaerator overflow drain Operating conditions unknown.

P&ID NC 9321-F-41293 Text19:

3-UHT-042 1

S Aux Steam to and from UH-T-1-30 Operating conditions unknown.

P&ID NC 9321-F-40573 Report No. 0700.104-17, Appendix C, Revision 2 Page C-110 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Return Unit Heater Steam Traps (UHT), Unit 3 Section B: SNM Program Lines 3-UHT-01: Auxiliary Steam to Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-UHT-043 1

S Aux Steam to and from UH-T-1-11 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-044 1

S Aux Steam to and from UH-T-1-10 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-045 1

S Aux Steam to and from UH-T-1-7 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-045-A 1

S Aux Steam thru Steam Trap UH-T-303 to House Service Boiler Condensate Return Tank header Operating conditions unknown.

P&ID NC 9321-F-41283, 9321-F-41293 Text19:

3-UHT-046 1

S Aux Steam to and from UH-T-1-6 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-047 1

S Aux Steam to and from UH-T-2-22 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-048 1

S Aux Steam to and from UH-T-1-8 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-049 1

S Aux Steam to and from UH-T-1-9 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-052 1

S Aux Steam to and from UH-T-1-12 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-053 1

S Aux Steam to and from UH-T-1-13 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-054 1

S Aux Steam to and from UH-T-1-14 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-055 1

S Aux Steam to and from UH-T-1-15 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-056 1

S Aux Steam to and from UH-T-2-23 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-057 1

S Aux Steam to and from UH-T-1-16 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-058 1

S Aux Steam to and from UH-T-2-26 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-059 1

S Aux Steam to and from UH-T-2-29 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-060 1.5 S

HSB-UH 1 Steam to Condensate Receiver thru Steam Trap UH-T-597-1 Operating conditions unknown.

P&ID NC 9321-F-41563 Report No. 0700.104-17, Appendix C, Revision 2 Page C-111 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Return Unit Heater Steam Traps (UHT), Unit 3 Section B: SNM Program Lines 3-UHT-01: Auxiliary Steam to Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-UHT-061 0.75 S

HSB-UH 2 Steam to Condensate Receiver thru Steam Trap UH-T-599-1 Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-UHT-062 0.75 S

HSB-UH 1 and 2 thru Steam Trap UH-T-601 to Condensate receiver Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-UHT-064 1

S Aux Steam to and from UH-T-7-1 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-065 1

S Aux Steam to and from UH-T-7-2 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-066 2

S Aux Steam to and from UH-T-8-1 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-066-A 0.75 S

Aux Steam from HSB-UH 3 thru Steam Trap UH-T-599-2 to House Service Boiler Condensate Return Tank Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-UHT-067 2

S Aux Steam header to Unit Heaters Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-068 1

S Aux Steam to and from UH-T-7-8 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-069 1

S Aux Steam to and from UH-T-7-7 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-069-A 0.75 S

Aux Steam from HSB-UH 4 thru Steam Trap UH-T-599-3 to House Service Boiler Condensate Return Tank Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-UHT-070 1

S Aux Steam to and from UH-T-7-6 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-071 1

S Aux Steam to and from UH-T-7-5 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-071-A 0.75 S

HSB-UH 4 to House Service Boiler Condensate Return tank thru Steam Trap UH-T-599-17 Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-UHT-072 1

S Aux Steam to and from UH-T-7-4 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-073 1

S Aux Steam to and from UH-T-7-3 Operating conditions unknown.

P&ID NC 9321-F-40573 Report No. 0700.104-17, Appendix C, Revision 2 Page C-112 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Return Unit Heater Steam Traps (UHT), Unit 3 Section B: SNM Program Lines 3-UHT-01: Auxiliary Steam to Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-UHT-074 1

S Aux Steam to and from UH-T-8-2 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-075 1

S Aux Steam to and from UH-T-8-3 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-079 0.75 S

HSB-UH 5-7, 16 and 17 thru UH-T-600 to Condensate Receiver Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-UHT-080 0.75 S

HSB-UH 5 thru UH-T-599-4 to Condensate Receiver Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-UHT-081 2

S Aux Steam to and from UH-T-9-3 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-081-A 0.75 S

HSB-UH 6 thru UH-T-599-5 to Condensate Receiver Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-UHT-082 2

S Aux Steam to and from UH-T-9-4 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-082-A 0.75 S

HSB-UH 7 thru UH-T-599-6 to Condensate Receiver Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-UHT-083-A 0.75 S

HSB-UH 16 thru UH-T-598-1 to Condensate Receiver Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-UHT-084-A 1

S HSB-UH 17 thru UH-T-599-14 to Condensate Receiver Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-UHT-091 2

S Aux Steam to and from UH-T-3-2 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-092 2

S Aux Steam to and from UH-T-3-1 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-093 1.5 S

Aux Steam to and from UH-T-6-1 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-094 0.75 S

Aux Steam to and from UH-T-2-2 Operating conditions unknown.

P&ID NC 9321-F-40573 Text19:

3-UHT-094-A 0.75 S

HSB-UH 8-10 thru UH-T-599-18 to Condensate Receiver Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-UHT-095 1

S Aux Steam to and from UH-T-3-2 Operating conditions unknown.

P&ID NC 9321-F-40573 Report No. 0700.104-17, Appendix C, Revision 2 Page C-113 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Return Unit Heater Steam Traps (UHT), Unit 3 Section B: SNM Program Lines 3-UHT-01: Auxiliary Steam to Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-UHT-095-A 0.75 S

HSB-UH-8 thru UH-T-599-7 to Condensate receiver Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-UHT-096 0.75 S

HSB-UH-9 thru UH-T-599-8 to Condensate receiver Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-UHT-097 2

S Aux Steam to and from UH-T-2-11 Operating conditions unknown.

P&ID NC 9321-F-40573, 9321-F-27273 Text19:

3-UHT-097-A 0.75 S

HSB-UH-10 thru UH-T-599-9 to Condensate receiver Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-UHT-098 8

S Aux Steam header to Unit Heaters Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UHT-100 1

S Aux Steam to and from UHT-2-15 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UHT-101 1

S Aux Steam to and from UHT-6-2 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UHT-110 0.75 S

Unit Heater thru Steam Trap UH-T-599-20 to Condensate Return Tank header Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-UHT-111 0.75 S

HSB-UH 11 thru Steam Trap UH-T-599-10 to Condensate Return Tank header Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-UHT-112 0.75 S

HSB-UH-14 thru Steam Trap UH-T-599-12 to Condensate Return Tank header Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-UHT-113 0.75 S

HSB-UH 13 thru Steam Trap UH-T-599-11 to Condensate Return Tank header Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-UHT-114 0.75 S

HSB-UH 18 thru UH-T-599-15 to Condensate Return Tank header Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-UHT-115 0.75 S

HSB-UH 15 thru Steam Trap UH-T-599-13 to Condensate Return Tank header Operating conditions unknown.

P&ID NC 9321-F-41563 Report No. 0700.104-17, Appendix C, Revision 2 Page C-114 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Return Unit Heater Steam Traps (UHT), Unit 3 Section B: SNM Program Lines 3-UHT-01: Auxiliary Steam to Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-UHT-124 1

S Aux Steam to and from UHT-2-7 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UHT-125 1

S Aux Steam to and from UHT-2-14 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UHT-125-A 2

S Aux Steam from HSB-HC-1A thru Steam Trap UH-T-597-2 to HSB-HC return header Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-UHT-126 1

S Aux Steam to and from UHT-2-9 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UHT-126-A 2

S Aux Steam from HSB-HC-1B thru Steam Trap UH-T-597-3 to HSB-HC return header Operating conditions unknown.

P&ID NC 9321-F-41563 Text19:

3-UHT-127 1

S Aux Steam to and from UHT-2-10 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UHT-128 1

S Aux Steam to and from UHT-2-5 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UHT-129 1

S Aux Steam to and from UHT-2-6 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UHT-130 1

S Aux Steam to and from UHT-2-8 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UHT-131 1

S Aux Steam to and from UHT-2-13 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UHT-132 1

S Aux Steam to and from UHT-2-12 Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UHT-136 0.75 S

Aux Steam thru Steam Trap UH-T-599-16 Operating conditions unknown.

PEPSE NC 9321-F-41563 Text19:

3-UHT-166 1.5 S

Aux Steam downstream of valve UH-723 thru UHT-10-1 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UHT-167 1.5 S

Aux Steam downstream of valve UH-725 thru UHT-10-2 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-27273 Text19:

3-UHT-168 1.5 S

Aux Steam downstream of valve UH-727 thru UHT-10-3 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-27273 Report No. 0700.104-17, Appendix C, Revision 2 Page C-115 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Return Unit Heater Steam Traps (UHT), Unit 3 Section B: SNM Program Lines 3-UHT-01: Auxiliary Steam to Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-UHT-188 1.5 S

Aux Steam thru Steam Trap UH-T-620-2 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-41553 Text19:

3-UHT-189 0.75 S

Aux Steam thru Steam Trap UH-T-617-1 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-41553 Text19:

3-UHT-191 0.75 S

Aux Steam thru Steam Trap UH-T-618 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-41553 Text19:

3-UHT-193 0.75 S

Aux Steam thru Steam Trap UH-T-617-3 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-41553 Text19:

3-UHT-195 1

S Aux Steam thru Steam Trap UH-T-619 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-41553 Text19:

3-UHT-197 0.75 S

Aux Steam thru Steam Trap UH-T-617-2 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-41553 Text19:

3-UHT-198 0.75 S

Aux Steam from Humidifier AS HU-2 thru Steam Trap UH-T-617-4 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-41553 Text19:

3-UHT-199 2

S Aux Steam from Hot Water heater thru Steam Trap UH-T-622 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-41553 Text19:

3-UHT-200 0.75 S

Aux Steam from Humidifier AS HU-1 thru Steam Trap UH-T-617-5 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-41553 Text19:

3-UHT-201 1

S Aux Steam from Heat Exchanger As HX-2 thru Steam Trap UH-T-620-1 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-41553 Text19:

3-UHT-202 2.5 S

Aux Steam from Heat Exchanger As HX-1 thru Steam Trap UH-T-621 to Cond Receiver header Operating conditions unknown.

P&ID NC 9321-F-41553 Report No. 0700.104-17, Appendix C, Revision 2 Page C-116 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Return Unit Heater Steam Traps (UHT), Unit 3 Section B: SNM Program Lines 3-UHT-01: Auxiliary Steam to Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-UHT-228 1.5 S

Main Steam leak thru Steam Trap UH-T-11 to House Service Boiler Condensate Return Tank Operating conditions unknown.

P&ID NC 9321-F-41283, 9321-F-41293 Section C: Excluded Lines 3-UHT-01: Auxiliary Steam to Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-UHT-025-A 0.75 E

Steam Trap UH-T-379 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41443 Text19:

3-UHT-027-A 0.75 E

Steam Trap UH-T-409-2 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41443 Text19:

3-UHT-029-A 0.75 E

Steam Trap Bypass through valve UH-471 Valve shown closed on P&ID.

P&ID EI 9321-F-41443 Text19:

3-UHT-030-A 0.75 E

Steam Trap UH-T-409-4 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41443 Text19:

3-UHT-032-A 0.75 E

Steam Trap UH-T-408-5 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41443 Text19:

3-UHT-034-A 0.75 E

Steam Trap UH-T-409-3 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41443 Text19:

3-UHT-035-A 0.75 E

Steam Trap UH-T-408-4 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41443 Text19:

3-UHT-036-A 0.75 E

Steam Trap UH-T-409-5 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41443 Text19:

3-UHT-037-A 0.75 E

Steam Trap UH-T-408-6 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41443 Text19:

3-UHT-038-A 0.75 E

Steam Trap UH-T-409-1 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41443 Text19:

3-UHT-040-A 0.75 E

Steam Trap UH-T-408-3 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41443 Text19:

3-UHT-042-A 1

E Steam trap UH-T-26 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41293 Text19:

3-UHT-042-B 0.75 E

Steam Trap UH-T-408-2 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41443 Report No. 0700.104-17, Appendix C, Revision 2 Page C-117 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Return Unit Heater Steam Traps (UHT), Unit 3 Section C: Excluded Lines 3-UHT-01: Auxiliary Steam to Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-UHT-043-A 0.75 E

Steam Trap UH-T-407-2 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41443 Text19:

3-UHT-045-B 0.75 E

Steam Trap UH-T-408-9 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41443 Text19:

3-UHT-046-A 1

E Steam Trap UH-T-303 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41283 Text19:

3-UHT-046-B 0.75 E

Steam Trap UH-T-408-7 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41443 Text19:

3-UHT-047-A 0.75 E

Steam Trap UH-T-408-8 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41443 Text19:

3-UHT-063 1.5 E

Steam Trap UH-T-597-1 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41563 Text19:

3-UHT-064-A 0.75 E

Steam Trap UH-T-599-1 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41563 Text19:

3-UHT-067-A 0.75 E

Steam Trap UH-T-599-2 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41563 Text19:

3-UHT-070-A 0.75 E

Steam Trap UH-T-599-3 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41563 Text19:

3-UHT-083 2

E UH-T-9-3 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-40573 Text19:

3-UHT-084 2

E UH-T-9-4 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-40573 Text19:

3-UHT-085 0.75 E

UH-T-599-4 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41563 Text19:

3-UHT-086 0.75 E

UH-T-599-5 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41563 Text19:

3-UHT-087 0.75 E

UH-T-599-6 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41563 Text19:

3-UHT-088 0.75 E

UH-T-599-14 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41563 Text19:

3-UHT-089 1

E UH-T-598-1 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41563 Text19:

3-UHT-098-A 0.75 E

UH-T-599-7 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41563 Text19:

3-UHT-099 0.75 E

UH-T-599-8 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41563 Text19:

3-UHT-100-A 0.75 E

UH-T-599-9 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41563 Text19:

3-UHT-117 0.75 E

UH-T-599-10 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41563 Report No. 0700.104-17, Appendix C, Revision 2 Page C-118 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

Condensate Return Unit Heater Steam Traps (UHT), Unit 3 Section C: Excluded Lines 3-UHT-01: Auxiliary Steam to Steam Traps Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-UHT-118 0.75 E

UH-T-599-12 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41563 Text19:

3-UHT-119 0.75 E

UH-T-599-11 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41563 Text19:

3-UHT-120 0.75 E

Uh-T-599-15 bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41563 Text19:

3-UHT-121 0.75 E

UH-T-599-13 bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41563 Text19:

3-UHT-129-A 1

E Steam Trap UH-T-597-3 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41563 Text19:

3-UHT-130-A 1

E Steam Trap UH-T-597-2 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41563 Text19:

3-UHT-206 0.75 E

Steam Trap UH-T-620-1 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41553 Text19:

3-UHT-207 1.5 E

Steam Trap UH-T-622 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41553 Text19:

3-UHT-209 1.5 E

Steam Trap UH-T-620-2 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41553 Text19:

3-UHT-210 2

E Steam Trap UH-T-621 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41553 Text19:

3-UHT-229 1

E Steam Trap UH-T-11 Bypass Valve shown closed on P&ID.

P&ID EI 9321-F-41283 Report No. 0700.104-17, Appendix C, Revision 2 Page C-119 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

MSR Vent Chamber Discharge (VCD), Unit 3 Section B: SNM Program Lines 3-VCD-01: Moisture Separator Reheater Vent Chamber Discharge Lines Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-VCD-001 3

S MSR 31A Vent Chamber Discharge Exact Conditions Unknown PEPSE NC 9321-F-20233 Sheet 1 Text19:

3-VCD-002 3

S MSR 32A Vent Chamber Discharge Exact Conditions Unknown PEPSE NC 9321-F-20233 Sheet 1 Text19:

3-VCD-003 3

S MSR 33A Vent Chamber Discharge Exact Conditions Unknown PEPSE NC 9321-F-20233 Sheet 1 Text19:

3-VCD-004 3

S MSR 31B Vent Chamber Discharge Exact Conditions Unknown PEPSE NC 9321-F-20233 Sheet 2 Text19:

3-VCD-005 3

S MSR 32B Vent Chamber Discharge Exact Conditions Unknown PEPSE NC 9321-F-20233 Sheet 2 Text19:

3-VCD-006 3

S MSR 33B Vent Chamber Discharge Exact Conditions Unknown PEPSE NC 9321-F-20233 Sheet 2 Text19:

3-VCD-010 3

S Vent Chamber Discharge Header to FWH 36A Exact Conditions Unknown PEPSE NC 9321-F-20233 Sheet 1, 9321-F-20203 Sheet 1 Text19:

3-VCD-011 3

S Vent Chamber Discharge Header to FWH 36A Exact Conditions Unknown PEPSE NC 9321-F-20233 Sheet 1, 9321-F-20203 Sheet 1 Text19:

3-VCD-012 3

S Vent Chamber Discharge Header to FWH 36B Exact Conditions Unknown PEPSE NC 9321-F-20233 Sheet 1, 9321-F-20203 Sheet 1 Text19:

3-VCD-013 3

S Vent Chamber Discharge Header to FWH 36C Exact Conditions Unknown PEPSE NC 9321-F-20233 Sheet 2, 9321-F-20203 Sheet 1 Text19:

3-VCD-014 3

S Vent Chamber Discharge Header to FWH36B Exact Conditions Unknown PEPSE NC 9321-F-20233 Sheet 2, 9321-F-20203 Sheet 1 Text19:

3-VCD-015 3

S Vent Chamber Discharge Header to FWH 36C Exact Conditions Unknown PEPSE NC 9321-F-20233 Sheet 2, 9321-F-20203 Sheet 1 Text19:

3-VCD-016 3

S Vent Chamber Discharge to Condenser No 31 Exact Conditions Unknown PEPSE NC 9321-F-20233 Sheet 1 Text19:

3-VCD-017 3

S Vent Chamber Discharge to Condenser No 31 Exact Conditions Unknown PEPSE NC 9321-F-20233 Sheet 1 Text19:

3-VCD-018 3

S Vent Chamber Discharge to Condenser No 33 Operating conditions unknown.

PEPSE NC 9321-F-20233 Sheet 1 Report No. 0700.104-17, Appendix C, Revision 2 Page C-120 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

MSR Vent Chamber Discharge (VCD), Unit 3 Section B: SNM Program Lines 3-VCD-01: Moisture Separator Reheater Vent Chamber Discharge Lines Line Number Size (in.)

Sus.

Cat.

Comments Reference Mod.

Ex. Crit.

P&ID No.

Line Description Text19:

3-VCD-022 3

S Vent Chamber Discharge to Condenser No 31 Exact Conditions Unknown PEPSE NC 9321-F-20233 Sheet 1 Text19:

3-VCD-023 3

S Vent Chamber Discharge to Condenser No 31 Exact Conditions Unknown PEPSE NC 9321-F-20233 Sheet 1 Text19:

3-VCD-024 3

S Vent Chamber Discharge to Condenser No 33 Operating conditions unknown.

PEPSE NC 9321-F-20233 Sheet 1 Text19:

3-VCD-025 3

S Vent Chamber Discharge to Condenser No 31 Exact Conditions Unknown PEPSE NC 9321-F-20233 Sheet 2 Text19:

3-VCD-026 3

S Vent Chamber Discharge to Condenser No 31 Exact Conditions Unknown PEPSE NC 9321-F-20233 Sheet 2 Text19:

3-VCD-027 3

S Vent Chamber Discharge to Condenser No 32 Operating conditions unknown.

PEPSE NC 9321-F-20233 Sheet 2 Section C: Excluded Lines 3-VCD-01: Moisture Separator Reheater Vent Chamber Discharge Lines Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-VCD-007 3

E Vent Chamber Discharge Header to FWH 36A Piping replaced with Chrome-moly P&ID EM 9321-F-20233 Sheet 1 Text19:

3-VCD-008 3

E Vent Chamber Discharge Header to FWH 36A Piping replaced with Chrome-moly P&ID EM 9321-F-20233 Sheet 1 Text19:

3-VCD-009 3

E Vent Chamber Discharge Header to FWH 36B Piping replaced with Chrome-moly P&ID EM 9321-F-20233 Sheet 1 Text19:

3-VCD-019 3

E Vent Chamber Discharge to Condenser No 31 Piping replaced with Stainless Steel P&ID EM 9321-F-20233 Sheet 1 Text19:

3-VCD-020 3

E Vent Chamber Discharge to Condenser No 31 Piping replaced with Stainless Steel P&ID EM 9321-F-20233 Sheet 1 Report No. 0700.104-17, Appendix C, Revision 2 Page C-121 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

MSR Vent Chamber Discharge (VCD), Unit 3 Section C: Excluded Lines 3-VCD-01: Moisture Separator Reheater Vent Chamber Discharge Lines Line Number Size (in.)

Sus.

Cat.

Comments Reference FAC Ex. Crit.

P&ID No.

Line Description Text19:

3-VCD-021 3

E Vent Chamber Discharge to Condenser No 33 Piping replaced with Stainless Steel P&ID EM 9321-F-20233 Sheet 1 Report No. 0700.104-17, Appendix C, Revision 2 Page C-122 of 123

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

CSI TECHNOLOGIES, INC.

FAC Exclusion Criteria (FAC Ex. Crit.) Legend:

EC EF EI EM EO EP EQ ER ET EW Excluded due to Combination of infrequent op above temp threshold Excluded due to low or no Flow Excluded due to Infrequent operation Excluded due to FAC-resistant Material Excluded due to high dissolved Oxygen content Exluded, does not contain Piping Excluded due to high steam Quality Excluded, Removed from service and "cut" and "capped" Excluded due to operating Temperature (single phase, < 200 deg F)

Excluded because system, subsytem, or line is non-Water Susceptibility Category (Sus. Cat.) Legend:

M S

E CHECWORKS Modeled Susceptible, not modeled Excluded from the FAC program (non-susceptible)

Model Exclusion Criteria (Mod. Ex. Crit.) Legend:

NC NL NM NQ NS NV Not modeled due to unknown or varying operating Conditions Not to be modeled due to Localized FAC susceptibility Non-Modelable due to conditions outside CHECWORKS Modeling capabilities Not to be modeled due to high steam Quality, CHECWORKS predictions are of little value Non-modelable due to Socket-welded fittings Not to be modeled because line is Visually inspected Report No. 0700.104-17, Appendix C, Revision 2 Page C-123 of 123

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Appendix D, Revision 2 Page D-1 of 5 Appendix D Revision History

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Appendix D, Revision 2 Page D-2 of 5 Revision 0 Initial Issue of document.

Revision 1 Systems, subsystem names, and line names were updated to incorporate the new system list.

Revision 2 SSE was updated to incorporate line replacements. Tables D.1 and D.2 below detail the changes:

Table D.1 Subsystem Changes







 

 

   





    

   

 !

"##$%&'$()*

 +!*,  -

./



    

   

 !

.,% 

Table D.2 Line Changes

'   

 

 

   



'         

 !

., 



'         

 !

., 

0

'         

 !

., 

)

'         

 !

., 

1

'         

 !

., 

2

'         

 !

., 

(1

'         

 !

"##$%&'$()*

 +!*,  -

(2

'         

 !

"##$%&'$()*

 +!*,  -



'         

 !

"##$%&'$()*

 +!*,  -

(

'         

 !

"##$%&'$()*

 +!*,  -



'         

 !

"##$%&'$()*

 +!*,  -



'         

 !

"##$%&'$()*

 +!*,  -

3

'         

 !

"##$%&'$()*

 +!*,  -

1

'         

 !

"##$%&'$()*

 +!*,  -

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Appendix D, Revision 2 Page D-3 of 5

'   

 

 

   

2

'         

 !

"##$%&'$()*

 +!*,  -



'         

 !

"##$%&'$()*

 +!*,  -

(

'         

 !

"##$%&'$()*

 +!*,  -

04500

'         

 !

., 

0450)

'         

 !

., 

04503

'         

 !

., 

04501

'         

 !

., 

04502

'         

 !

., 

045)

'         

 !

., 

045)(

'         

 !

., 

045)

'         

 !

., 

045)6

'         

 !

., 

045)0

'         

 !

 

045)0,!

., 

045)0-

,       77 !

., 

045))

'         

 !

 

045)),!

., 

045))-

,       77 !

., 

045)3

'         

 !

 

045)3,!

., 

045)3-

,       77 !

., 

)45(

'         

 !

 

)45(-!

., 

)45(,

,       77 !

., 

)45

'         

 !

 

)45-!

., 

)45,

,       77 !

., 

)45

'         

 !

., 

)456

'         

 !

., 

)450

'         

 !

., 

)45)

'         

 !

., 

)453

'         

 !

., 

)451

'         

 !

., 

)452

'         

 !

., 

)45(

'         

 !

., 

))

'         

 !

"##$%&'$()*

 +!*,  -

)1

'         

 !

"##$%&'$()*

 +!*,  -

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Appendix D, Revision 2 Page D-4 of 5

'   

 

 

   

)((

'         

 !

"##$%&'$()*

 +!*,  -

)(

'         

 !

"##$%&'$()*

 +!*,  -

)()

'         

 !

"##$%&'$()*

 +!*,  -

)(1

'         

 !

"##$%&'$()*

 +!*,  -

)(2

'         

 !

"##$%&'$()*

 +!*,  -

./61

'         

 !

., 

./62

'         

 !

., 

%32

'         

 !

 

%32-!

., 

%32,

,       77 !

., 

%1

'         

 !

 

%1-!

., 

%1,

,       77 !

., 

%1(

'         

 !

 

%1(-!

., 

%1(,

,       77 !

., 

%1

'         

 !

 

%1-!

., 

%1,

,       77 !

., 

%1

'         

 !

 

%1-!

., 

%1,

,       77 !

., 

%16

'         

 !

 

%16-!

., 

%16,

,       77 !

., 

%10

'         

 !

 

%10,!

., 

%10-

,       77 !

., 

%1)

'         

 !

 

%1),!

., 

%1)-

,       77 !

., 

%13

'         

 !

 

%13,!

., 

%13-

,       77 !

., 

%11

'    %  7 .,     !

., 

%12

'    %  7 .,     !

., 

%2

'    %  7 .,     !

., 

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Appendix D, Revision 2 Page D-5 of 5

'   

 

 

   

%2(

'        8   !



   

(1!* +!0*!

%2

'        8   !



   

(1!* +!0*!

%2

'        8   !



   

(1!* +!0*!

%26

'        8   !



   

(1!* +!0*!

%20

'        8   !



   

(1!* +!0*!

%2)

'        8   !



   

(1!* +!0*!

%$())

'         

 !

"##$%&'$()*

 +!*,  -

%$()3

'         

 !

"##$%&'$()*

 +!*,  -

#2

'         

 !

"##$%&'$()*

 +!*,  -

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Attachment A, Revision 2 Page Attach A-1 of 6 Attachment A Industry FAC Experience Table

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Attachment A, Revision 2 Page Attach A-2 of 6 Industry experience is an important factor in the identification of systems, subsystems, and lines susceptible to Flow-Accelerated Corrosion (FAC). A table of important industry events and their applicability to Indian Point 3 was compiled using the following sources:

  • Recommendations for an Effective Flow-Accelerated Corrosion Program, EPRI NSAC 202L-R3, 2006.
  • EPRI, Flow-Accelerated Corrosion in Power Plants, B. Chexal et al, EPRI TR-106611-R1, 1998.
  • CHUG Plant Experience Database, Revision 2, December 1995.
  • 26th CHUG Meeting Presentation by Jeff Horowitz "Review and Lessons Learned from Historical FAC Failures".
  • 31st CHUG Meeting Presentation by Aaron Kelley "Unit 1 #2 LP Heater ES Nozzles".
  • 32th CHUG Meeting Presentation by Doug Munson "Update on Mihama-3".
  • 33rd CHUG Meeting Presentation by Aaron Kelley "Results of L2R10 Inspections at LaSalle Unit 2".
  • 33rd CHUG Meeting Presentation by Whit Gallman "Unisolable Steam Leak Downstream of Valve 2HM-23".
  • CHUG Conference Meeting Minutes, FAC Experience Reports, and Presentations.
  • FACnet Email Message Archive.
  • Secondary Pipe Rupture (9 August 2004, Mihama Unit 3, Kansai EPC), WANO EAR TYO 04-013, October 8, 2004.
  • Information Notice 82-2: Failures in Turbine Exhaust Lines, U.S. Nuclear Regulatory Commission (NRC), July 9, 1982.
  • Information Notice 86-106: Feedwater Line Break, U.S. Nuclear Regulatory Commission (NRC), December 16, 1986.
  • Information Notice 86-106, Supplement 1: Feedwater Line Break, U.S. Nuclear Regulatory Commission (NRC), February 13, 1987.
  • Information Notice 86-106, Supplement 2: Feedwater Line Break, U.S. Nuclear Regulatory Commission (NRC), March 18, 1987.
  • NRC Bulletin No. 87-01: Thinning of Pipe Walls in Nuclear Power Plants, U.S.

Nuclear Regulatory Commission (NRC), July 9, 1987.

Nuclear Regulatory Commission (NRC), August 4, 1987.

April 22, 1988.

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Attachment A, Revision 2 Page Attach A-3 of 6

  • Information Notice 86-106, Supplement 3: Feedwater Line Break, U.S. Nuclear Regulatory Commission (NRC), November 10, 1988.
  • Erosion/Corrosion-Induced Pipe Wall Thinning, Generic Letter 89-08, U.S. Nuclear Regulatory Commission (NRC), May 2, 1989.
  • Investigation into Flow-Accelerated Corrosion at Low Temperatures, Document 1015070, Electric Power Research Institute (EPRI), November 2007.
  • Flow-Accelerated Corrosion - The Entrance Effect, Document 1015072, Electric Power Research Institute (EPRI), November 2007.
  • Erosive Attack, Technical Update 1015071, Electric Power Research Institute (EPRI),

November 2007.

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Attachment A, Revision 2 Page Attach A-4 of 6 Item Number System Location/Area Plant Plant Type Year Notes 1

All Downstream of Flow Orifices and Flow Meters Many

BWR, PWR Failures reported in piping immediately downstream of orifices and flow meters. This is a generic issue applicable to all systems.

2 All Downstream of Control Valves (level control valves)

Millstone 2&3, Surry

BWR, PWR Many plants reported instances of FAC degradation and some significant failures (Millstone 2&3, Surry). This is a generic issue applicable to all systems.

3 All Downstream of Leaking Valves and Steam Traps Many All Leaking valves and steam traps may be found by plant thermal performance evaluation. Downstream piping may experience severe conditions and may have been excluded from FAC Program due to infrequent operation. This is a generic issue applicable to all systems.

4 All Miscellaneous Drains to Common Headers into Condenser Many All Extensive industry exp in miscellaneous drain headers from steam drains to the condenser. In addition to FAC, these headers are susceptible to liquid impingement erosion and/or flashing/cavitation as explained in EPRI Erosive Attack Technical Update 1015071.

5 Condensate Feedwater Pump Suction Surry Unit 2 PWR 1986 Pipe rupture at Surry Unit 2. Occurred in 18" OD, Tnom = 0.5" elbow upstream of feedwater pumps (first elbow off header to FWP). T=374 deg F.

6 Condensate Condensate (between 4th highest pressure FWH and dearator)

Mihama PWR 2004 Failure in condensate system at Mihama. Occurred in 22" pipe downstream of flow measuring orifice. 284 deg F 7

Extraction Steam (or Bleed Steam)

Extraction Steam (All stages carrying wet steam)

Oconee, Vermont
Yankee, Trojan, Zion, Browns Ferry
BWR, PWR 1982 Failures in steam lines due to FAC. All extraction stages carrying wet steam are susceptible to FAC. In general, all plants have experience with thinning in the extraction steam system (plants listed appeared in NRC Information Notice 82-22) 8 Extraction Steam (or Bleed Steam)

HP Extraction 2nd Stage ANO 2 PWR 1989 Fishmouth failure at ANO 2. Occurred in 14" OD, 2-phase flow. Failure at Zion (1988), Oconee (1982).

9 Extraction Steam (or Bleed Steam)

HP Extraction Sequoyah 2 PWR 1993 Fishmouth failure at Sequoyah 2. Occurred in 10" straight pipe downstream of tee in HP extraction.

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Attachment A, Revision 2 Page Attach A-5 of 6 Item Number System Location/Area Plant Plant Type Year Notes 10 Extraction Steam (or Bleed Steam)

Extraction (4th Stage)

Fort Calhoun PWR 1997 Fishmouth rupture at Fort Calhoun in third elbow (12" bent pipe R/D =

5) downstream of turbine in extraction steam system. Section of upstream piping had been replaced in 1985 due to FAC; this downstream section was not inspected. 411 deg F, 2 phase 11 Extraction Steam (or Bleed Steam)

Extraction (carbon steel components in Cr-Mo/Stainless/etc line)

LaSalle BWR 2004 Failure of LP Heater inlet nozzles (carbon steel nozzles in Cr-Mo line).

Also through-walls on carbon steel pup piece on bellows assembly in Cr-Mo line (bellows was stainless steel). The conclusion from these events is that to be non-susceptible to FAC the entire line (incl. nozzles, valves, pup pieces, etc.) must be of FAC-resistant material.

12 Feedwater Feedwater Pump Outlet

& DS of CVs Oyster Creek BWR 1978 Thinning caused by FAC at Oyster Creek in 1978. Cracking observed at feedwater pump outlet and downstream of flow/level control valves.

13 Feedwater Feedwater Pump Discharge Navajo Fossil 1982 Pipe rupture at Navajo. Occurred in 10" OD, Tnom = 0.365" elbow downstream of boiler feed pump. T=360 deg F.

14 Feedwater Final Feedwater (Safety-Related)

Trojan PWR 1987 Extensive thinning to min acceptable wall thickness at Trojan in safety related feedwater (and non-safety related). High velocity and large counterbores exacerbated FAC.

15 Feedwater Feedwater at Flow Measurement Orifice Loviisa PWR 1990 Rupture at Loviisa. Occurred in feedwater system at flow measurement orifice.

16 Feedwater Feedwater Pleasant Prairie Fossil 1995 Instantaneous double-ended pipe break at Pleasant Prairie. Occurred in 12" feedwater line downstream of valve station and upstream of economizer and boiler.

17 Feedwater Control Valve Bypass Lines San Onofre and Diablo Canyon

BWR, PWR Serious thinning at San Onofre and Diablo Canyon (could be valve leakage, left open at full power-high velocity, or infrequent but severe conditions).

18 Feedwater Feedwater Pump Min Flow (Recirculation)

Lines Many All Feedwater pump min flow lines to condenser have experienced significant degradation.

19 Heater Drain Heater Drain Pump Recirc (Bypass)

Millstone 2 PWR 1995 Failure at Millstone 2. Occurred in 8" recirc line from heater drain pump to heater drain tank. Line operated during startup only (0-30% power).

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Attachment A, Revision 2 Page Attach A-6 of 6 Item Number System Location/Area Plant Plant Type Year Notes 20 Heater Vents Feedwater Heater Vents to Condenser

ANO, Kewaunee,
McGuire, Point Beach, Waterford
PWR, BWR Extensive FAC-induced thinning found throughout this system at many plants. Some plants have replaced the entire system with non-susceptible material (stainless steel or Cr-Mo).

21 Main Steam Cross-Under Piping (also called Cold Reheat, HP Turbine to Moisture Separator)

North Anna, ANO, Point Beach, D.C.

Cook

BWR, PWR Significant FAC in cross-under piping at North Anna, ANO, and Point Beach. Some plants have small amounts of Cu/Cr in this lines which significantly reduces FAC.

22 Moisture Separator Drain Moisture Separator Drain Tank Drain Millstone 3 PWR 1990 Catastrophic failure at Millstone 3. Occurred in 6" OD Moisture Sep.

Drain Tank drain immediately downstream of level CV. 380 deg F, 0%

quality.

23 Reheater Drain Reheater Drain Tank Drain Millstone 2 PWR 1991 Rupture at Millstone 2. Occurred in 8" Reheater Drain Tank drain immediately downstream of level CV. 463 deg F, 0% quality.

24 Reheater Drain First Stage Reheater Drain Callaway PWR 1999 Failure at Callaway just downstream of long horizontal section in first stage reheater drain. 417 deg F, 4.5% quality 25 Reheater Drain Moisture Separator Reheater Drain/Vent to Drain Tank (Scavenging Steam)

McGuire PWR 2005 Unisolable steam leak occurred in 2" line that vents wet steam from MSR to drain tank. Flashing contributed to wear (pressure drop caused by "tortuous path" through many fittings in line). 540 deg F, wet steam 26 Multiple Systems Deoxygenated lines operating at 120ºF South Texas Project, Palo Verde, Surry

PWR, BWR Some plants have experienced Low-Temperature FAC wear in deoxygenated, neutral water at about 120ºF as per EPRI Technical Report 1015170 Investigation into Flow-Accelerated Corrosion at Low Temperatures.

27 Multiple Systems Multiple Locations Diablo

Canyon, Salem, V. C.

Summer

PWR, BWR Pipes made of corrosive material have shown high corrosion rates downstream of welds connecting non-resistant material to the resistant material.

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Attachment B, Revision 2 Page Attach B-1 of 4 Attachment B Referenced Correspondence and Communications

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Attachment B, Revision 2 Page Attach B-2 of 4 Email from Chris Pott (CSI) to Ian Mew (IPEC) regarding information requests, dated 10/2/2009.

CSI Document 0700.104.C.014

Ian, My name is Chris Pott and I am one of the engineers working on the SSE/SNM Analysis for Indian Point along with Ryan Doremus. Ive completed most of the work on the IPEC3 SSE/SNM but need a few items in order to complete the rest of the documents. Any additional information for Unit 3 would be helpful. The questions that I have are as follows:
1. Could I get any P&IDs that would contain Gland Seal Piping for Unit 3? A document I found that would be useful was B237144-4 for Unit 2 which shows the Drain and Gland Seal for the low and high pressure turbines. A similar P&ID for Unit 3 would be excellent.
2. I have been using the flow diagram symbols list associated with Unit 2 but have noticed that the P&IDs for Unit 3 reference a Unit 3 Flow Diagrams List. This List would help me to complete the Systems List for the SSE/SNM. Could you please send the diagram 9321-D-20163?
3. In addition to the above requests, I have noticed a few other P&IDs I need to complete the SSE/SNM. Could you please send the following P&IDs:
1. "Auxiliary Steam Supply and Condensate Return System," Dwg. No. 9321-F-40573.
2. "Auxiliary Boiler Reboiler Steam System," Dwg. No. 9321-F-41573.
3. Sheet 1 of 2 House Boiler Bldg. Aux. Steam Supply System," Dwg. No. 9321-F-41283.
4. 9321-F-20343
5. 9321-F-20323
6. 9321-F-41443 sheet 1
4. Lastly, IP3-RPT-MULT-03162 references several System Descriptions Documents. These SDs would help clarify lines on the SSE/SNM that I need. Could you please send the following System Descriptions:
1. Unit No.3, System Description No. 7, "Steam Generator Blowdown System.
2. Unit No.3, System Description No. 18, "Main Steam Reheat Steam System.
3. Unit No.3, System Description No. 18.1, "Main Dumps and Low Pressure Bypass Dumps.
4. Unit No.3, System Description No. 19, "Extraction Steam Vents and Drains.
5. Unit No.3, System Description No. 21, "Feedwater System.
6. Unit No.3, System Description No. 26, "Main Turbine Generator.
7. Unit No.3, System Description No. 29, "Auxiliary Steam System.
8. Unit No. 3, System Description No. 29.11, House Service Boiler.
9. Unit No.3, System Description, "Steam Generator Blowdown Recovery System.

If you have any questions, let me know.

Thank you, Christopher R. Pott Engineer CSI Technologies, Inc.

847-836-3000 x792

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Attachment B, Revision 2 Page Attach B-3 of 4 Conversation between Ian Mew (IPEC) and Chris Pott (CSI) regarding responses to information requests, dated 11/5/2009.

CSI Document # 0700.104.C.015 On November 5, 2009 a telephone conversation was held between Chris Pott (CSI) and Ian Mew (IPEC) to discuss data that was needed to finish the Unit 3 SSE/SNM. The data, which consisted of 14 system descriptions and 7 drawings was then delivered to CSI via the CSI FTP site and filed into the IPEC 3 input data folder.

CSI TECHNOLOGIES, INC.

Indian Point 3 FAC System Susceptibility Evaluation (SSE)

Report No. 0700.104-17, Attachment B, Revision 2 Page Attach B-4 of 4 Conversation between Ian Mew (IPEC) and Chris Pott (CSI) regarding a missing P&ID, dated 11/17/2009.

0700.104.C.017 In a conversation with Ian Mew on Thursday, Nov 19,2009, it was discovered that a particular drawing, 9321-F-80793 could not be located. The issue involved with this is that there is an auxiliary steam header going from the auxiliary steam supply system to this drawing and a condensate return header coming from this drawing. It was determined the steam supply entering the drawing, which shows the Outage Support Building, is susceptible, non-modelable, at a Consequence of Failure level of 2. Because the drawing cannot be located, the lines could not be analyzed. It should be noted that the Aux Steam lines in the Outage Support Building are potentially susceptible to FAC and should be treated as such until proven otherwise.