Jan. 16, 2012 Page 1

of 2

MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2012-2351 USER INFORMATION:

GERLACH*ROSE M EMPL#:028401 CA#:

0363 Address: NUCSA2 Phone#:

254-3194 TRANSMITTAL INFORMATION:

TO:

GERLACH*ROSE M 01/16/2012 LOCATION:

NRC REGION 1 TECH SPECS FROM:

NUCLEAR RECORDS DOCUMENT CONTROL CENTER (NUCSA-2)

THE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU.

HARDCOPY USERS MUST ENSURE THE DOCUMENTS PROVIDED MATCH THE INFORMATION ON THIS TRANSMITTAL.

WHEN REPLACING THIS MATERIAL IN YOUR HARDCOPY MANUAL, ENSURE THE UPDATE DOCUMENT ID IS THE SAME DOCUMENT ID YOU'RE REMOVING FROM YOUR MANUAL.

TOOLS FROM THE HUMAN PERFORMANCE TOOL BAG SHOULD6'E*°*

UTILIZED TO ELIMINATE THE CHANCE OF ERRORS.

ATTENTION:

"REPLACE" directions do not affect the Table of Contents, Therefore no TOC will be issued with the updated material.

TSB2 -

TECHNICAL SPECIFICATIONS BASES UNIT 2 MANUAL REMOVE MANUAL TABLE OF CONTENTS DATE: 11/30/2011 ADD MANUAL TABLE OF CONTENTS DATE: 01/13/2012 CATEGORY:

DOCUMENTS TYPE: TSB2 bti

Jan. 16, 2012 Page 2

of 2

ID:

TEXT 3.4.3 REMOVE:

REV:2 ADD:

REV: 3 CATEGORY:

DOCUMENTS TYPE: TSB2 ID:

TEXT LOES REMOVE:

REV:104 ADD:

REV: 105 ANY DISCREPANCIES WITH THE MATERIAL PROVIDED, CONTACT DCS @ X3107 OR X3136 FOR ASSISTANCE.

UPDATES FOR HARDCOPY MANUALS WILL BE DISTRIBUTED WITHIN 3 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.

PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON COMPLETION OF UPDATES.

FOR ELECTRONIC MANUAL

USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.

SSES MANUAL Manual Name:

TSB2 Manual

Title:

TECHNICAL SPECIFICATIONS BASES UNIT 2 MANUAL Table Of Contents Issue Date:

01/13/2012 Procedure Name Rev TEXT LOES 105

Title:

LIST OF EFFECTIVE SECTIONS Issue Date 01/13/2012 Change ID Change Number TEXT TOC

Title:

TABLE OF CONTENTS 18 09/01/2010 K"

TEXT 2.1.1 4

Title:

SAFETY LIMITS (SLS)

REACTOR TEXT 2.1.2 1

Title:

SAFETY LIMITS (SLS)

REACTOR 05/06/201 CORE SLS 10/04/20Q 09 YSýTEMy (RCS)

PRESSURE SL TEXT 3.0 3

Title:

LIMITING CONDITION FOR C TEXT 3.1.1 1

Title:

REACTIVITY CONTROL,,SYSTI MARGIN (SDM)

TEXT 3.1.2

Title:

REACTIVITY TEXT 3.1.3

Title:

REACTIV'ITY, TEXT 3.1.4

Title:

REACTIVITY

\\> 0 11/18/2002 SYSTEMS REACTIVITY ANOMALIES 2

01/19/2009 SYSTEMS CONTROL ROD OPERABILITY 4

01/30/2009 CONTROL SYSTEMS CONTROL ROD SCRAM TIMES TEXT 3.1.5

Title:

REACTIVITY TEXT, 3.1.6

Title:

REACTIVITY 1

CONTROL SYSTEMS 2

CONTROL SYSTEMS 07/06/2005 CONTROL ROD SCRAM ACCUMULATORS 03/24/2005 ROD,.TTERN CONTROL Pagel of 8

Report Date: 01/16/1 Page J, of 8

Report Date: 01/16/1

SSES MANUAL Manual Name:

TSB2 Manual

Title:

TECHNICAL SPECIFICATIONS BASES UNIT 2 MANUAL TEXT 3.1.7

Title:

REACTIVITY CONTROL TEXT 3.1.8

Title:

REACTIVITY CONTROL TEXT 3.2.1

Title:

POWER DISTRIBUTION 3

10/04/2007 SYSTEMS STANDBY LIQUIDCONTROL (SLC)

SYSTEM 3

05/06/2009 SYSTEMS SCRAM DISCHARGE VOLUME (SDV)

VENT AND DRAIN VALVES 4

05/06/2009 LIMITS AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)

TEXT 3.2.2 3

05/06/2009

Title:

POWER DISTRIBUTION LIMITS MINIMUM CRITICAL POWER RATIO (MCPR)

TEXT 3.2.3 2

05/06/2009

Title:

POWER DISTRIBUTION LIMITS LINEAR HEAT GENERATION RATE LHGR TEXT 3.3.1.1 4

05/06/2009

Title:

INSTRUMENTATION REACTOR PROTECTION SYSTEM (RPS)

INSTRUMENTATION TEXT 3.3.1.2 2

01/19/2009

Title:

INSTRUMENTATION SOURCE RANGE MONITOR (SRM)

INSTRUMENTATION TEXT 3.3.2.1

Title:

INSTRUMENTATION TEXT 3.3.2.2

Title:

INSTRUMENTATION 2

04/09/2007 CONTROL ROD BLOCK INSTRUMENTATION 1

05/06/2009 FEEDWATER -

MAIN TURBINE HIGH WATER LEVEL TRIP INSTRUMENTATION TEXT 3.3.3.1 7

10/27/2008

Title:

INSTRUMENTATION POST ACCIDENT MONITORING (PAM)

INSTRUMENTATION TEXT 3.3.3.2 1

04/18/2005

Title:

INSTRUMENTATION REMOTE SHUTDOWN SYSTEM TEXT 3.3.4.1 1

05/06/2009

Title:

INSTRUMENTATION END OF CYCLE RECIRCULATION PUMP TRIP (EOC-RPT)

INSTRUMENTATION Page 2 of 8

Report Date: 01/16/12

SSES MANUAL Manual Name:

TSB2 Manual

Title:

TECHNICAL SPECIFICATIONS BASES UNIT 2 MANUAL TEXT 3.3.4.2 0

11/18/2002

Title:

INSTRUMENTATION ANTICIPATED TRANSIENT WITHOUT SCRAM RECIRCULATION PUMP TRIP (ATWS-RPT)

INSTRUMENTATION TEXT 3.3.5.'1

Title:

INSTRUMENTATION TEXT 3.3.5.2

Title:

INSTRUMENTATION TEXT 3.3.6.1

Title:

INSTRUMENTATION 4

08/20/2009 EMERGENCY CORE COOLING SYSTEM (ECCS)

INSTRUMENTATION 0

11/18/2002 REACTOR CORE ISOLATION COOLING (RCIC)

SYSTEM INSTRUMENTATION 4

05/06/2009 PRIMARY CONTAINMENT ISOLATION INSTRUMENTATION TEXT 3.3.6.2 4

09/01/2010

Title:

INSTRUMENTATION SECONDARY CONTAINMENT ISOLATION INSTRUMENTATION TEXT 3.3.7.1

Title:

INSTRUMENTATION INSTRUMENTATION 2

10/27/2008 CONTROL ROOM EMERGENCY OUTSIDE AIR SUPPLY (CREOAS)

SYSTEM TEXT 3.3.8.1 3

12/17/2007

Title:

INSTRUMENTATION LOSS OF POWER (LOP)

INSTRUMENTATION TEXT 3.3.8.2 0

11/18/2002

Title:

INSTRUMENTATION REACTOR PROTECTION SYSTEM (RPS)

ELECTRIC POWER MONITORING TEXT 3.4.1

Title:

REACTOR COOLANT TEXT 3.4.2

Title:

REACTOR COOLANT TEXT 3.4.3

Title:

REACTOR COOLANT TEXT 3.4.4

Title:

REACTOR COOLANT 4

07/20/2010 SYSTEM (RCS)

RECIRCULATION LOOPS OPERATING 2

07/20/2010 SYSTEM (RCS) JET PUMPS 3

01/13/2012 SYSTEM (RCS)

SAFETY/RELIEF VALVES (S/RVS) 0 1.1/18/2002 SYSTEM (RCS)

RCS OPERATIONAL LEAKAGE Page~

of ~

Report Date: 01/16/12 Page 3 of 8

Report Date: 01/16/12

SSES MANUTAL Manual Name:

TSB2 Manual

Title:

TECHNICAL SPECIFICATIONS BASES UNIT 2 MANUAL TEXT 3.4.5 3

03/10/2010

Title:

REACTOR COOLANT SYSTEM (RCS)

RCS PRESSURE ISOLATION VALVE (PIV) LEAKAGE TEXT 3.4.6 3

01/25/2011

Title:

REACTOR COOLANT SYSTEM (RCS)

RCS LEAKAGE DETECTION INSTRUMENTATION TEXT 3.4.7 2

10/04/2007

Title:

REACTOR COOLANT SYSTEM (RCS)

RCS SPECIFIC ACTIVITY TEXT 3.4.8

Title:

REACTOR COOLANT HOT SHUTDOWN TEXT 3.4.9

Title:

REACTOR COOLANT COLD SHUTDOWN 1

SYSTEM (RCS) 0 SYSTEM (RCS) 04/18/2005 RESIDUAL HEAT REMOVAL (RHR)

SHUTDOWN COOLING SYSTEM 11/18/2002 RESIDUAL HEAT REMOVAL (RHR) 05/06/2 009 RCS PRESSURE AND TEMPERATURE SHUTDOWN COOLING SYSTEM0 TEXT 3.4.10 3

Title:

REACTOR COOLANT SYSTEM (RCS)

(P/T) LIMITS TEXT 3.4.11 0

11/18/2002

Title:

REACTOR COOLANT SYSTEM (RCS)

REACTOR STEAM DOME PRESSURE TEXT 3.5.1 3

01/16/2006

Title:

EMERGENCY CORE COOLING SYSTEMS (ECCS)

AND REACTOR SYSTEM ECCS -

OPERATING TEXT 3.5.2 0

11/18/2002

Title:

EMERGENCY CORE COOLING SYSTEMS (ECCS)

AND REACTOR SYSTEM ECCS -

SHUTDOWN TEXT 3.5.3 2

07/09/2010

Title:

EMERGENCY CORE COOLING SYSTEMS (ECCS)

AND REACTOR SYSTEM RCIC SYSTEM CORE ISOLATION COOLING (RCIC)

CORE ISOLATION COOLING (RCIC)

CORE ISOLATION COOLING (RCIC)

TEXT 3.6.1.1

Title:

PRIMARY CONTAINMENT 4

11/09/2011 TEXT 3.6.1.2 1

05/06/2009

Title:

CONTAINMENT SYSTEMS PRIMARY CONtAINMENT AIR LOCK PageA of 8 Report Date: 01/16/12 Page I of 8

Report Date: 01/16/12

SSES MANUALI Manual Name:

TSB2 Manual

Title:

TECHNICAL SPECIFICATIONS BASES UNIT 2 MANUAL TEXT 3.6.1.3

Title:

CONTAINMENT TEXT 3.6.1.4

Title:

CONTAINMENT TEXT 3.6.1.5

Title:

CONTAINMENT TEXT 3.6.1.6

Title:

CONTAINMENT TEXT 3.6.2.1

Title:

CONTAINMENT TEXT 3.6.2.2

Title:

CONTAINMENT TEXT 3.6.2.3

Title:

CONTAINMENT TEXT 3.6.2.4

Title:

CONTAINMENT TEXT 3.6.3.1

Title:

CONTAINMENT TEXT 3.6.3.2

Title:

CONTAINMENT TEXT 3.6.3.3

Title:

CONTAINMENT TEXT 3.6.4.1

Title:

CONTAINMENT 11 04/14/2010 SYSTEMS PRIMARY CONTAINMENT ISOLATION VALVES (PCIVS) 1 05/06/2009 SYSTEMS CONTAINMENT PRESSURE 1

10/05/2005 SYSTEMS DRYWELL AIR TEMPERATURE 0

11/18/2002 SYSTEMS SUPPRESSION CHAMBER-TO-DRYWELL VACUUM BREAKERS 2

12/17/2007 SYSTEMS SUPPRESSION POOL AVERAGE TEMPERATURE 0

11/18/2002 SYSTEMS SUPPRESSION POOL WATER LEVEL 1

01/16/2006 SYSTEMS RESIDUAL HEAT REMOVAL (RHR)

SUPPRESSION POOL COOLING 0

11/18/2002 SYSTEMS RESIDUAL HEAT REMOVAL (RHR)

SUPPRESSION POOL SPRAY 2

06/13/20.06 SYSTEMS PRIMARY CONTAINMENT HYDROGEN RECOMBINERS 1

04/18/2005 SYSTEMS DRYWELL AIR FLOW SYSTEM 0

11/18/2002 SYSTEMS PRIMARY CONTAINMENT OXYGEN CONCENTRATION 7

1.0,04/2007 SYSTEMS SECONDARY CONTAINMENT Page~

of 8 Report Date: 01/16/12 Page a of 8

Report Date: 01/16/12

SSES M~ANUJAL Manual Name:

TSB2 Manual

Title:

TECHNICAL SPECIFICATIONS BASES UNIT 2 MANUAL TEXT 3.6.4.2 3

03/10/2010

Title:

CONTAINMENT SYSTEMS SECONDARY CONTAINMENT ISOLATION VALVES (SCIVS)

TEXT 3.6.4.3 4

09/21/2006

Title:

CONTAINMENT SYSTEMS STANDBY GAS TREATMENT (SGT)

SYSTEM TEXT 3.7.1

Title:

PLANT SYSTEMS ULTIMATE HEAT 4

04/05/2010 RESIDUAL HEAT REMOVAL SERVICE WATER (RHRSW)

SYSTEM AND THE SINK (UHS)

TEXT 3.7.2

Title:

PLANT TEXT 3.7.3

Title:

PLANT TEXT 3.7.4

Title:

PLANT TEXT 3.7.5

Title:

PLANT TEXT 3.7.6

Title:

PLANT TEXT 3.7.7

Title:

PLANT TEXT 3.8.1 2

05/02/2008 SYSTEMS EMERGENCY SERVICE WATER (ESW)

SYSTEM 1

01/08/2010 SYSTEMS CONTROL ROOM EMERGENCY OUTSIDE AIR SUPPLY (CREOAS)

SYSTEM 0

1'/18/2002 SYSTEMS CONTROL ROOM FLOOR COOLING SYSTEM 1

10/04/2007 SYSTEMS MAIN CONDENSER OFFGAS 3

01/25/2011 SYSTEMS MAIN TURBINE BYPASS SYSTEM 1

10/04/2007 SYSTEMS SPENT FUEL STORAGE POOL WATER LEVEL

8.

05/06/2009

Title:

ELECTRICAL POWER SYSTEMS AC SOURCES -

OPERATING TEXT 3.7.8 0

05/06/2009

Title:

MAINE TURBINE PRESSURE REGULATION SYSTEM TEXT 3.8.2 0

11/18/2002

Title:

ELECTRICAL POWER SYSTEMS-AC SOURCES -

SHUTDOWN Page~

of 8 Report Date: 01/16/12 Page 6 of.8 Report Date: 01/16/12

SSES MANUAL Manual Name:

TSB2 Manual

Title:

TECHNICAL SPECIFICATIONS BASES UNIT 2 MANUAL TEXT 3. 8.3

Title:

ELECTRICAL TEXT 3.8.4

Title:

ELECTRICAL TEXT 3.8.5

Title:

ELECTRICAL TEXT 3.8.6

Title:

ELECTRICAL TEXT 3.8.7

Title:

ELECTRICAL TEXT 3.8.8

Title:

ELECTRICAL TEXT 3.9.1

Title:

REFUELING TEXT 3.9.2

Title:

REFUELING TEXT 3.9.3

Title:

REFUELING TEXT 3.9.4

Title:

REFUELING TEXT 3.9.5

Title:

REFUELING POWER SYST POWER SYST POWER SYST POWER SYST POWER SYST POWER SYST OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS 2

04/14/2010

'EMS DIESEL FUEL OIL LUBE OIL AND STARTING AIR 3

01/19/2009

'EMS DC SOURCES -

OPERATING 1

12/14/2006

'EMS DC SOURCES -

SHUTDOWN 1

12/14/2006

'EMS BATTERY CELL PARAMETERS 3

03/31/2006

'EMS DISTRIBUTION SYSTEMS OPERATING 0

11/18/2002

'EMS DISTRIBUTION SYSTEMS SHUTDOWN 0

11/18/2002 REFUELING EQUIPMENT INTERLOCKS 1

09/01/2010 REFUEL POSITION ONE-ROD-OUT INTERLOCK 0

11/18/2002 CONTROL ROD POSITION 0

11/18/2002 CONTROL ROD POSITION INDICATION 0

11/18/2002 CONTROL ROD OPERABILITY -

REFUELING TEXT 3.9.6 1

10/04/2007

Title:

REFUELING OPERATIONS REACTOR PRESSURE VESSEL (RPV) WATER LEVEL Page2 at 8

Report Date: 01/16/12 Page 7 of 8

Report Date: 01/16/12

SSES MANUALs Manual Name:

  • TSB2 Manual

Title:

TECHNICAL SPECIFICATIONS BASES UNIT 2 MANUAL TEXT 3.9.7 0

11/18/2002

Title:

REFUELING OPERATIONS RESIDUAL HEAT REMOVAL (RHR)

HIGH WATER LEVEL TEXT 3.9.8 0

11/18/2002

Title:

REFUELING OPERATIONS RESIDUAL HEAT REMOVAL (RHR)

LOW WATER LEVEL TEXT 3.10.1

Title:

SPECIAL TEXT 3.10.2

Title:

SPECIAL TEXT 3.10.3

Title:

SPECIAL TEXT 3.10.4

Title:

SPECIAL TEXT 3.10.5

Title:

SPECIAL TEXT 3.10.6

Title:

SPECIAL TEXT 3.10.7

Title:

SPECIAL TEXT 3.10.8

Title:

SPECIAL OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS 1

01/23/2008 INSERVICE LEAK AND HYDROSTATIC TESTING OPERATION 0

11/18/2002 REACTOR MODE SWITCH INTERLOCK TESTING 0

11/18/2002 SINGLE CONTROL ROD WITHDRAWAL HOT SHUTDOWN 0

1ii/18/2002 SINGLE CONTROL ROD WITHDRAWAL -

COLD SHUTDOWN 0

11/18/2002 SINGLE CONTROL ROD DRIVE (CRD)

REMOVAL -

REFUELING 0

11/18/2002 MULTIPLE CONTROL ROD WITHDRAWAL REFUELING 1

03/24/2005 CONTROL ROD TESTING-OPERATING 2

04/09/2007 SHUTDOWN MARGIN (SDM)

TEST -

REFUELING Page~

of 8 Report Date: 01/16/12 Page a of 8

Report Date: 01/16/12

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision TOC Table of Contents 18 B 2.0 SAFETY LIMITS BASES Page TS / B 2.0-1 1

Pages TS / B 2.0-2 and TS / B 2.0-3 4

Page TS / B 2.0-4 6

Pages TS / B 2.0-5 through TS / B 2.0-8 1

B 3.0 LCO AND SR APPLICABILITY BASES Page TS / B 3.0-1 1

Pages TS / B 3.0-2 through TS / B 3.0-4 0

Pages TS / B 3.0-5 through TS / B 3.0-7 1

Page TS / B 3.0-8 3

Pages TS / B 3.0-9 through Page TS / B 3.0-11 2

Page TS / B 3.0-11a 0

Page TS / B 3.0-12 1

Pages TS / B 3.0-13 through TS / B 3.0-15 2

Pages TS / B 3.0-16 and TS / B 3.0-17 0

B 3.1 REACTIVITY CONTROL BASES Pages B 3.1-1 through B 3.1-4 0

Page TS / B 3.1-5 1

Pages TS / B 3.1-6 and TS / B 3.1-7 2

Pages B 3.1-8 through B 3.1-13 0

Page TS / B 3.1-14 1

Page TS / B 3.1-15 0

Page TS / B 3.1-16 1

Pages TS / B 3.1-17 through TS / B 3.1-19 0

Pages TS / B 3.1-20 and TS / B 3.1-21 1

Page TS / B 3.1-22 0

Page TS / B 3.1-23 1

Page TS / B 3.1-24 0

Pages TS / B 3.1-25 through TS / B 3.1-27 1

Page TS / B 3.1-28 2

Page TS / 3.1-29 1

Pages B 3.1-30 through B 3.1-33 0

Pages TS / B 3.1.34 through TS / B 3.1-36 1

Pages TS / B 3.1-37 and TS / B 3.1-38 2

Pages TS / B 3.1-39 and TS / B 3.1-40 2

Page TS / B 3.1-40a 0

Page TS / B 3.1-41 1

Page TS / B 3.1-42 2

SUSQUEHANNA

- UNIT 2 TS/BLOES-1 Revision 105 SUSQUEHANNA - UNIT 2 TS / B LOES-1.

Revision 105

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision Pages TS / B 3.1-43 1

Page TS / B 3.1-44 0

Page TS / B 3.1-45 3

Page TS / B 3.1-46 0

Page TS / B 3.1-47 1

Pages TS / B 3.1-48 and TS / B 3.1-49 1

Page B 3.1-50 0

Page TS / B 3.1-51 3

B 3.2 POWER DISTRIBUTION LIMITS BASES Pages TS / B 3.2-1 and TS / B 3.2-2 2

Page TS / B 3.2-3 4

Page TS / B 3.2-4 1

Page TS / B 3.2-5 3

Page TS / B 3.2-6 4

Page TS / B 3.2-7 3

Pages TS / B 3.2-8 and TS / B 3.2-9 4

Pages TS / B 3.2-10 through TS / B 3.2-12 2

Page TS / B 3.2-13 1

B 3.3 INSTRUMENTATION Pages TS / B 3.3-1 through TS / B 3.3-4 1

Page TS / B 3.3-5 2

Page TS / B 3.3-6 1

Page TS / B 3.3-7 3

Page TS / B 3.3-8 4

Pages TS / B 3.3-9 through TS / B 3.3-13 3

Page TS / B 3.3-14 4

Pages TS / B 3.3-15 and TS / B 3.3-16 2

Pages TS / B 3.3-17 through TS / B 3.3-21 3

Pages TS / B 3.3-22 through TS / B 3.3-27 2

Page TS / B 3.3-28 3

Page TS / B 3.3-29 4

Pages TS / B 3.3-30 and TS / B 3.3-31 3

Pages TS / B 3.3-32 and TS / B 3.3-33 4

Page TS / B 3.3-34 2

Page TS / B 3.3-34a 1

Pages TS / B 3.3-34b through TS / B 3.3-34d 0

Page TS / B 3.3-34e 1

Pages TS / B 3.3-34f through TS / B 3.3-34i 0

Pages TS / B 3,3-35 and TS / B 3.3-36 2

Pages TS / B 3.3-37 and TS / B 3.3-38 1

SUSQUEHANNA - UNIT 2 TS / B] LOES-2 Revision 105

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision Page TS / B 3.3-39 2

Pages TS / B 3.3-40 through TS / B 3.3-43 2

Pages TS / B 3.3-44 through TS / B 3.3-54 3

Pages TS / B 3.3-54a through TS / B 3.3-54e 0

Page TS / B 3.3-55 1

Page B 3.3-56 0

Page TS / B 3.3-57 1

Page B 3.3-58 0

Page TS / B 3.3-59 1

Pages B 3.3-60 through B 3.3-63 0

Pages TS / B 3.3-64 and TS / B 3.3-65 2

Page TS / B 3.3-66 4

Page TS / B 3.3-67 3

Page TS / B 3.3-68 4

Page TS / B 3.3.69 5

Page TS / B 3.3-70 4

Page TS / B 3.3-71 3

Pages TS / B 3.3-72 and TS / B 3.3-73 2

Page TS / B 3.3-74 3

Page TS / B 3.3-75 2

Pages TS / B 3.3-75a and TS / B 3.3-75 b 6

Page TS / B 3.3-75c 5

Pages B 3.3-76 and TS / B 3.3-77 0

Page TS / B 3.3-78 1

Pages B 3.3-79 through B 3.3-81 0

Page TS / B 3.3-82 1

Page B 3.3-83 0

Pages TS / B 3.3-84 and TS / B 3.3-85 1

Page 3.3-86 0

Page TS / B 3.3-87 1

Page B 3.3-88 0

Page TS / B 3.3-89 1

Pages B 3.3-90 and B 3.3-91 0

Pages TS / B 3.3-92 through TS / B 3.3-103 1

Page TS / B 3.3-104 3

Pages TS / B 3.3-105 and TS/ B 3.3-106 1

Page TS / B 3.3-107 2

Page TS/ B 3.3-108 1

Page TS / B 3.3-109 2

Pages TS / B 3.3-110 through TS/B 3.3-112 1

Page TS / B 3.3-113 2

Page TS / B 3.3-114 1

Page TS / B 3.3-115 2

Page TS / B 3.3-116 3

Pages TS / B 3.3-117 and TS / B 3.3-118 2

SUSQUEHANNA

- UNIT 2 TS/BLOES-3 Revision 105 SUSQUEHANNA - UNIT 2 TS / B LOES-3 Revision 105

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision Pages TS / B 3.3-119 through TS / B 3.3-120 1

Pages TS / B 3.3-121 and TS / B 3.3-122 2

Page TS / B 3.3-123 1

Page TS / B 3.3-124 2

Page TS / B 3.3-124a 0

Page TS / B 3.3-125 1

Page TS / B 3.3-126 2

Page TS / B 3.3-127 3

Page TS / B 3.3-128 2

Pages TS / B 3.3-129 through TS / B 3.3-131 1

Page TS / B 3.3-132 2

Pages TS / B 3.3-133 and TS / B 3.3-134 1

Pages B 3.3-135 through B 3.3-137 0

Page TS / B 3.3-138 1

Pages B 3.3-139 through B 3.3-149 0

Pages TS/ B 3.3-150 and TS / B 3.3-151 1

Pages TS / B 3.3-152 through TS / B 3.3-154 2

Page TS / B 3.3-155 1

Pages TS / B 3.3-156 through TS / B 3.3-158 2

Pages TS / B 3.3-159 through TS / B 3.3-161 1

Page TS / B 3.3-162 1

Page TS / B 3.3-163 2

Page TS / B 3.3-164 1

Pages TS / B 3.3-165 and TS / B 3.3-166 2

Pages TS / B 3.3-167 and TS I B 3.3-168 1

Pages TS / B 3.3-169 and TS / B 3.3-170 2

Pages TS / B 3.3-171 through TS / B 3.3-177 1

Page TS / B 3.3-178 2

Page TS / B 3.3-179 3

Page TS / B 3.3-179a 2

Page TS / B 3.3-180 1

Page TS / B 3.3-181 3

Page TS / B 3.3-182 1

Page TS / B 3.3-183 2

Page TS / B 3.3-184 1

Page TS / B 3.3-185 4

Page TS / B 3.3-186 1

Pages TS / B 3.3-187 and TS /B 3.3-188 2

Pages TS / B 3.3-189 through TS / B 3.3-191 1

Page TS / B 3.3-192 0

Page TS / B 3.3-193 1

Pages TS / B 3.3-194 and TS / B 3.3-195 0

Page TS / B 3.3-196 2

SUSQUEHANNA

- UNIT 2 TS/BLOES-4 Revision 105 SUSQUEHANNA - UNIT 2 TS / B LOES-4 Revision 105

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision Pages TS / B 3.3-197 through TS / B 3.3-205 0

Page TS / B 3.3-206 1

Pages B 3.3-207 through B 3.3-209 0

Page TS / B 3.3-210 1

Page TS / B 3.3-211 2

Pages TS / B 3.3-212 and TS / B 3.3-213 1

Pages B 3.3-214 through B 3.3-220 0

B 3.4 REACTOR COOLANT SYSTEM BASES Pages TS / B 3.4-1 and TS / B 3.4-2 2

Pages TS / B 3.4-3 through TS / B 3.4-5 4

Pages TS / B 3.4-6 through TS / B 3.4-9 3

Page TS / B 3.4-10 1

Pages TS / B 3.4-11 and TS / B 3.4-12 0

Page TS / B 3.4-13 1

Page TS / B 3.4-14 0

Page TS / B 3.4-15 2

Pages TS / B 3.4-16 and TS / B 3.4-17 4

Page TS / B 3.4-18 2

Pages B 3.4-19 through B 3.4-23 0

Pages TS / B 3.4-24 through TS / B 3.4-27 0

Page TS / B 3.4-28 1

Page TS / B 3.4-29 3

Page TS / B 3.4-30 1

Page TS / B 3.4-31 0

Pages TS / B 3.4-32 and TS / B 3.4-33 1

Page TS / B 3.4-34 0

Pages TS / B 3.4-35 and TS / B 3.4-36 1

Page TS / B 3.4-37 2

Page B 3.4-38 1

Pages B 3.4-39 and B 3.4-40 0

Page TS / B 3.4-41 1

Pages B 3.4-42 through B 3.4-48 0

Page TS / B 3.4-49 3

Pages TS / B 3.4-50 through TS / B 3.4-52 2

Page TS / B 3.4-53 1

Pages TS / B 3.4-54 through TS / B 3.4-57 2

Pages TS / B 3.4-58 through TS / B 3.4-60 1

B 3.5 ECCS AND RCIC BASES Pages TS / B 3.5-1 and TS / B 3.5-2 1

Pages TS / B 3.5-3 through TS / B 3.5-6 2

Pages TS / B 3.5-7 through TS / B 3.5-10 1

Pages TS / B 3.5-11 and TS / B 3.5-12 2

Pages TS / B 3.6-13 and TS / B 3.5-14 1

SUSQUEHANNA - UNIT 2 TS / B LOES-5 Revision 105

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision Pages TS / B 3.5-15 and TS / B.3.5-16 2

Page TS / B 3.5-17 3

Page TS / B 3.5-18 1

Pages B 3.5-19 through B 3.5-24 0

Pages TS / B 3.5-25 through TS / B 3.5-27 1

Page TS / B 3.5-28 0

Page TS / B 3.5-29 1

Pages TS / B 3.5-30 and TS / B 3.5-31 0

B 3.6 CONTAINMENT SYSTEMS BASES Page TS / B 3.6-1 2

Page TS / B 3.6-1a 3

Page TS / B 3.6-2 4

Page TS / B 3.6-3 3

Page TS / B 3.6-4 4

Page TS / B 3.6-5 3

Page TS / B 3.6-6 4

Pages TS / B 3.6-6a and TS / B 3.6-6b 3

Page TS / B 3.6-6c 0

Page B 3.6-:7 0

Page TS /3.6-8 1

Pages B 3.6-9 through B 3.6-14 0

Page TS / B 3.6-15 3

Page TS / B 3.6-15a 0

Page TS / B 3.6-15b 3

Pages TS / B 3.6-16 and TS / B 3.6-17 2

Page TS / B 3.6-17a 0

Pages TS / B 3.6-18 and TS / B 3.6-19 1

Page TS / B 3.6-20 2

Page TS / B 3.6-21 3

Pages TS / B 3.6-21a and TS / B 3.6-21b 0

Pages TS / B 3.6-22 and TS / B 3.6-23 2

Pages TS / B 3.6-24 and TS / B 3.6-25 1

Pages TS / B 3.6-26 and TS / B 3.6-27 3

Page TS / B 3.6-28 7

Page TS / B 3.6-29 5

Page TS / B 3.6-29a 0

Page TS / B 3.6-30 2

Page TS / B 3.6-31 3

Pages TS / B 3.6-32 and TS / B 3.6-33 2

SUSQUEHANNA - UNIT 2 TS/BLOES-6 Revision 105 SUSQUEHANNA - UNIT 2 TS / B LOES-6 Revision 105

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision Page TS / B 3.6-34 1

Page TS / B 3.6-35 3

Pages TS / B 3.6-36 and TS / B 3.6-37 2

Page TS / B 3.6-38 3

Page TS / B 3.6-39 7

Page TS / B 3.6-40 1

Pages B 3.6-41 and B 3.6-42 0

Pages TS / B 3.6-43 and TS / B 3.6-44 1

Page TS / B 3.6-45 2

Pages TS / B 3.6-46 through TS / B 3.6-50 1

Page TS / B 3.6-51 2

Pages B 3.6-52 through B 3.6-55 0

Pages TS / B 3.6-56 and TS / B 3.6-57 2

Pages B 3.6-58 through B 3.6-62 0

Pages TS / B 3.6-63 and TS / B 3.6-64 1

Pages B 3.6-65 through B 3.6-68 0

Pages B 3.6-69 through B 3.6-71 1

Page TS / B 3.6-72 2

Pages TS / B 3.6-73 and TS / B 3.6-74 1

Pages B 3.6-75 and B 3.6-76 0

Page TS / B 3.6-77 1

Pages B 3.6-78 through B 3.6-82 0

Page TS / B 3.6-83 3

Page TS / B 3.6-84 2

Page TS / B 3.6-85 4

Page TS / B 3.6-86 through TS / B 3.6-87a 2

Page TS / B 3.6-88 4

Page TS / B 3.6-89 2

Page TS / B 3.6-90 3

Pages TS / B 3.6-91 through TS / B 3.6-95 1

Page TS / B 3.6-96 2

Pages TS / B 3.6-97 and TS / B 3.6-98 1

Page TS / B 3.6-99 3

Page TS / B 3.6-99a 0

Pages TS / B 3.6-100 and TS / B 3.6-101 1

Pages TS / B 3.6-102 and TS / B 3.6-103 2

Page TS / B 3.6-104 3

Page TS / B 3.6-105 2

Page TS / B 3.6-106 3

SUSQUEHANNA-UNIT2 TS / B] LOES-7 Revision 105

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision B 3.7 PLANT SYSTEMS BASES Page TS / B 3.7-1 3

Page TS / B 3.7-2 4

Pages TS / B 3.7-3 through TS / B 3.7-5 3

Page TS / B 3.7-5a 1

Page TS / B 3.7-6 3

Page TS / B 3.7-6a 2

Page TS / B 3.7-6b 1

Page TS / B 3.7-6c 2

Page TS / B 3.7-7 3

Page TS / B 3.7-8 2

Pages B 3.7-9 through B 3.7-11 0

Pages TS / B 3.7-12 and TS / B 3.7-13 2

Pages TS / B 3.7-14 through TS / B 3.7-18 3

Page TS / B 3.7-18a 1

Pages TS / B 3.7-18b through TS / B 3.7-18e 0

Pages TS / B 3.7-19 through TS / B 3.7-24 1

Pages TS / B 3.7-25 and TS / B 3.7-26 0

Page TS / B 3.7-27 4

Pages TS / B 3.7-28 and TS / B 3.7-29 3

Pages TS / B 3.7-30 and TS / B 3.7-31 1

Page TS / B 3.7-32 0

Page TS / B 3.7-33 1

Pages TS / B 3.7-34 through TS / B 3.7-37 0

B 3.8 ELECTRICAL POWER SYSTEMS BASES Page TS / B 3.8-1 1

Pages B 3.8-2 and B 3.8-3 0

Page TS / B 3.8-4 1

Pages TS / B 3.8-4a and TS / B 3.8-4b 0

Pages TS / B 3.8-5 and TS / B 3.8-6 3

Page TS / B 3.8-6a 1

Pages B 3.8-7 and B 3.8-8 0

Page TS / B 3.8-9 2

Pages TS / B 3.8-10 and TS / B 3.8-11 1

Pages B 3.8-12 through B 3.8-18 0

Page TS / B 3.8-19 1

Pages B 3.8-20 through B 3.8-22 0

Page TS / B 3.8-23 1

Page B 3.8-24 0

Pages TS / B 3.8-25 and TS / B 3.8-26 1

SUSQUEHANNA-UNIT2 TS/B LOES-8 Revision 105 SUSQUEHANNA - UNIT 2 TS / B LOES-8 Revision 105

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision Pages B 3.8-27 through B 3.8-35 0

Page TS / B 3.8-36 1

Page TS / B 3.8-37 0

Page TS / B 3.8-38 1

Pages TS / B 3.8-39 through TS / B 3.8-46 0

Page TS / B 3.8-47 1

Pages TS / B 3.8-48 through TS / B 3.8-50 0

Pages TS / B 3.8-51 through TS / B 3.8-53 1

Page TS / B 3.8-54 0

Page TS / B 3.8-55 1

Pages TS / B 3.8-56 through TS / B 3.8-59 2

Pages TS / B 3.8-60 through TS / B 3.8-64 3

Page TS / B 3.8-65 4

Page TS / B 3.8-66 5

Pages TS / B 3.8-67 and TS / B 3.8-68 4

Page TS / B 3.8-69 5

Pages TS / B 3.8-70 through TS / B 3.8-83 1

Pages TS / B 3.8-83A through TS / B 3.8-83D 0

Pages B 3.8-84 through B 3.8-85 0

Page TS / B 3.8-86 1

Page TS / B 3.8-87 2

Pages TS / B 3.8-88 through TS / B 3.8-93 1

Pages B 3.8-94 through B 3.8-99 0

B 3.9 REFUELING OPERATIONS BASES Pages TS / B 3.9-1 and TS / B 3.9-2 1

Pages TS / B 3.9-2a through TS / B 3.9-5 1

Pages TS / B 3.9-6 through TS / B 3.9-8 0

Pages B 3.9-9 through B 3.9-18 0

Pages TS / B 3.9-19 through TS / B 3.9-21 1

Pages B 3.9-22 through B 3.9-30 0

B 3.10 SPECIAL OPERATIONS BASES Page TS / B 3.10-1 2

Pages TS / B 3.10-2 through TS / B 3.10-5 1

Pages B 3.10-6 through B 3.10-32 0

Page TS / B 3.10-33 2

Page B 3.10-34 0

Page B 3.10-35 1

Pages B 3.10-36 and B 3.10-37 0

Page B 3.10-38 1

Page TS / B 3.10-39 2

TSB2 Text LOES.doc 1/10/20 12 SUSQUEHANNA - UNIT 2 TS / B LOES-9 Revision 105

PPL Rev. 3 S/RVs B 3.4.3 B 3.4 REACTOR COOLANT SYSTEM (RCS)

B 3.4.3 Safety/Relief Valves (S/RVs)

BASES BACKGROUND The ASME Boiler and Pressure Vessel Code requires the reactor pressure vessel be protected from overpressure during upset conditions by self-actuated safety valves. As part of the nuclear pressure relief system, the size and number of S/RVs are selected such that peak pressure in the nuclear system will not exceed the ASME Code limits for the reactor coolant pressure boundary (RCPB).

The S/RVs are located on the main steam lines between the reactor vessel and the first isolation valve within the drywell. There are a total of 16 S/RVs of which any 14 are required to be OPERABLE. The S/RVs can actuate by either of two modes: the safety mode or the relief mode. In the safety mode (or spring mode of operation), the valve opens when.

steam pressure at the valve inlet overcomes the spring force holding the valve closed. This satisfies the Code requirement.

0 Each S/RV discharges steam through a discharge line to a point below the minimum water level in the suppression pool. Six S/RVs also serve as the Automatic Depressurization System (ADS) valves. The ADS requirements are specified in LCO 3.5.1, "ECCS-Operating."

APPLICABLE SAFETY ANALYSES The overpressure protection system must accommodate the most severe pressurization transient. Evaluations have determined that the most severe transient is the closure of all main steam isolation valves (MSIVs),

followed by reactor scram on high neutron flux (i.e., failure of the direct scram associated with MSIV position) (Ref. 1). For the purpose of the analyses, 14 of the 16 S/RVs are assumed to operate in the safety mode.

The analysis results demonstrate that the design S/R.V capacity is capable of maintaining reactor pressure below the ASME Code limit of 110% of vessel design pressure (110% x 1250 psig = 1375 psig). This LCO helps to ensure that the acceptance limit of 1375 psig is met during the Design Basis Event.

(continued)

SUSQUEHANNA - UNIT 2 TS /B 3.4-15 Revision 2

PPL Rev. 3 S/RVs B 3.4.3 BASES APPLICABLE From an overpressure standpoint, the design basis events are bounded SAFETY by the MSIV closure with flux scram event described above. Reference 2 ANALYSES discusses additional events that are expected to actuate the S/RVs.

(continued)

S/RVs satisfy Criterion 3 of the NRC Policy Statement (Ref. 4).

LCO The safety function of 14 of the 16 S/RVs are required to be OPERABLE to satisfy the assumptions of the safety analysis (Refs. 1 and 2). The requirements of this LCO are applicable only to the capability of the S/RVs to mechanically open to relieve excess pressure when the lift setpoint is exceeded (safety function).

The S/RV setpoints are established to ensure that the ASME Code limit on peak reactor pressure is satisfied. The ASME Code specifications require the lowest safety valve setpoint to be at or below vessel design pressure (1250 psig) and the highest safety valve to be set so that the total accumulated pressure does not exceed 110% of the design pressure for overpressurization conditions. The transient evaluations in the FSAR are based on these setpoints, but also include the additional uncertainty of + 3%, - 5 % of the nominal setpoint to provide an added degree of conservatism.

Operation with fewer valves OPERABLE than specified, or with setpoints outside the ASME limits, could result in a more severe reactor response to a transient than predicted, possibly resulting in the ASME Code limit on reactor pressure being exceeded.

APPLICABILITY In MODES 1, 2, and 3, all required S/RVs must be OPERABLE, since considerable energy may be in the reactor core and the limiting design basis transients are assumed to occur in these MODES. The S/RVs may be required to provide pressure relief to discharge energy from the core until such time that the Residual Heat Removal (RHR) System is capable of dissipating the core heat.

In MODE 4 reactor pressure is low enough that the overpressure limit is unlikely to be approached by assumed (continued)

SUSQUEHANNA - UNIT 2 TS / B 3.4-16 Revision 4

PPL Rev. 3 S/RVs B 3.4.3 BASES SURVEILLANCE SURVEQIR NENS SR 3.4.3.1 (continued)

REQUIREMENTS The Frequency of this Surveillance is established in accordance with the Inservice Testing Program.

REFERENCES

1. FSAR, Section 5.2.2.1.4.
2. FSAR, Section 15.
3. ASME Operation and Maintenance Code.
4. Final Policy Statement on Technical Specifications Improvements, July 22, 1993 (58 FR 39132).

SUSQUEHANNA - UNIT 2 TS / B 3.4-18 Revision 2

Jan. 16, 2012 Page 1

of 2

MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2012-2493 USER INFORMATION:

GERLACH*ROSE M EMPL#:028401 CA#:

0363 Address: NUCSA2 Phone#:

254-3194 TRANSMITTAL INFORMATION:

TO:

GERLACH*ROSE M 01/16/2012 LOCATION:

NRC REGION 1 TECH SPECS FROM:

NUCLEAR RECORDS DOCUMENT CONTROL CENTER (NUCSA-2)

THE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU.

HARDCOPY USERS MUST ENSURE THE DOCUMENTS PROVIDED MATCH THE INFORMATION ON THIS TRANSMITTAL.

WHEN REPLACING THIS MATERIAL IN YOUR HARDCOPY MANUAL, ENSURE THE UPDATE DOCUMENT ID IS THE SAME DOCUMENT ID YOU'RE REMOVING FROM YOUR MANUAL.

TOOLS FROM THE HUMAN PERFORMANCE TOOL BAG SHOULD *BE UTILIZED TO ELIMINATE THE CHANCE OF ERRORS.

ATTENTION:

"REPLACE" directions do not affect the Table of Contents, Therefore no TOC will be issued with the updated material.

TSBI -

TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL REMOVE MANUAL TABLE OF CONTENTS ADD MANUAL TABLE OF CONTENTS DATE: 11/30/2011 DATE: 01/13/2012 CATEGORY:

DOCUMENTS TYPE: TSBI Y

Jan. 16, 2012 Page 2

of 2

ID:

TEXT 3.4.3 ADD:

REV:

3 REMOVE:

REV:2 CATEGORY:

ID:

TEXT REMOVE:

DOCUMENTS TYPE: TSB1 LOES REV:102 ADD:

REV: 103 ANY DISCREPANCIES WITH THE MATERIAL PROVIDED, CONTACT DCS @ X3107 OR X3136 FOR ASSISTANCE.

UPDATES FOR HARDCOPY MANUALS WILL BE DISTRIBUTED WITHIN 3 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.

PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON COMPLETION OF UPDATES.

FOR ELECTRONIC MANUAL

USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.

SSES MANUJAL Manual Name:

TSB1 Manual

Title:

TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL Table Of Contents Issue Date:

01/13/2012 Procedure Name Rev TEXT LOES 103

Title:

LIST OF EFFECTIVE SECTIONS Issue Date 01/13/2012 Change ID Change Number TEXT TOC

Title:

TABLE OF CONTENTS 20 09/01/2010 TEXT 2. 1.1 5

Title:

SAFETY LIMITS (SLS)

REACTOR 05/06/2009 CORE' SLS TEXT 2.1.2 1

/'10/04/2007

Title:

SAFETY LIMITS (SLS)

REACTOR COOLANT SYSTEM (RCS)

PRESSURE S TEXT 3. 0

Title:

LIMITING CONDITION 3

0'8.0//2009 FOR OPERATION (LCO)

APPLICABILITY TEXT 3. 1.1

Title:

REACTIVITY TEXT 3.1.2

Title:

REACTIVITY TEXT 3.1.3

Title:

REACTIVITY TEXT 3.1.4

Title:

REACTIVITY TEXT 3.1.5

Title:

REACTIVITY TEXT 3.1.6

Title:

REACTIVITY 1

CONTROL SYSTEMS 0

CONTROL SYSTEMS 2

CONTROL SYSTEMS 04/18/2006 SHUTDOWN MARGIN (SDM) 11/15/2002 REACTIVITY ANOMALIES 01/19/2009 CONTROL ROD OPERABILITY 4

01/30/2009 CONTROL SYSTEMS CONTROL ROD SCRAM TIMES 1

CONTROL SYSTEMS 2

CONTROL SYSTEMS 07/06/2005 CONTROL ROD SCRAM ACCUMULATORS 04/18/2006 ROD PATTERN CONTROL Pagel of 8 Report Date: 01/16/12 Page I of 8 Report Date: 01/16/12

SSES MANUALJ Manual Name:

TSBl Manual

Title:

TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.1.7

Title:

REACTIVITY CONTROL TEXT 3.1.8

Title:

REACTIVITY CONTROL 3

04/23/2008 SYSTEMS STANDBY LIQUID CONTROL (SLC)

SYSTEM 3

05/06/2009 SYSTEMS SCRAM DISCHARGE VOLUME (SDV)

VENT AND DRAIN VALVES TEXT 3.2.1 2

04/23/2008

Title:

POWER DISTRIBUTION LIMITS AVERAGE PLANAR LINEAR HEAT GENERATION TEXT 3.2.2 3

05/06/2009

Title:

POWER DISTRIBUTION LIMITS MINIMUM CRITICAL POWER RATIO (MCPR)

TEXT 3,2.3 2

04/23/2008

Title:

POWER DISTRIBUTION LIMITS LINEAR HEAT GENERATION RATE (LHGR)

TEXT 3.3.1.1 4

04/23/2008

Title:

INSTRUMENTATION REACTOR PROTECTION SYSTEM (RPS)

INSTRUMENTATION TEXT 3,3.1.2 2

01/19/2009

Title:

INSTRUMENTATION SOURCE RANGE MONITOR (SRM)

INSTRUMENTATION TEXT 3.3.2.1 3

04/23/2008

Title:

INSTRUMENTATION CONTROL ROD BLOCK INSTRUMENTATION RATE (APLHGR)

TEXT 3.3.2.2 2

04/05/2010

Title:

INSTRUMENTATION FEEDWATER MAIN TURBINE HIGH WATER LEVEL TRIP INSTRUMENTATION TEXT 3.3.3.1 8

10/27/2008

Title:

INSTRUMENTATION POST ACCIDENT MONITORING (PAM)

INSTRUMENTATION TEXT 3.3.3.2

Title:

INSTRUMENTATION TEXT 3.3.4.1

Title:

INSTRUMENTATION 1

04/18/2005 REMOTE SHUTDOWN SYSTEM 1

04/23/2008 END OF CYCLE RECIRCULATION PUMP TRIP (EOC-RPT)

INSTRUMENTATION*

PageZ of 8

Report Date: 01/16/12 Page 2 of 8

Report Date: 01/16/12

SSES MANUAL Manual Name:

TSBI Manual

Title:

TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.3.4.2 0

11/15/2002

Title:

INSTRUMENTATION ANTICIPATED TRANSIENT WITHOUT SCRAM RECIRCULATION PUMP TRIP (ATWS-RPT)

INSTRUMENTATION TEXT 3.3.5.1

Title:

INSTRUMENTATION 3

08/20/2009 EMERGENCY CORE COOLING SYSTEM (ECCS)

INSTRUMENTATION TEXT 3.3.5.2 0

11/15/2002

Title:

INSTRUMENTATION REACTOR CORE ISOLATION COOLING (RCIC)

SYSTEM INSTRUMENTATION TEXT 3.3.6.1

Title:

INSTRUMENTATION TEXT 3.3.6.2

Title:

INSTRUMENTATION TEXT 3.3.7.1

Title:

INSTRUMENTATION INSTRUMENTATION TEXT 3.3.8.1

Title:

INSTRUMENTATION TEXT 3.3.8.2

Title:

INSTRUMENTATION 4

04/23/2008 PRIMARY CONTAINMENT ISOLATION INSTRUMENTATION 4

09/01/2010 SECONDARY CONTAINMENT ISOLATION INSTRUMENTATION 2

10/27/2008 CONTROL ROOM EMERGENCY OUTSIDE AIR SUPPLY (CREOAS)

SYSTEM 2

12/17/2007 LOSS OF POWER (LOP)

INSTRUMENTATION 0

11/15/2002 REACTOR PROTECTION SYSTEM (RPS)

ELECTRIC POWER MONITORING TEXT 3.4.1

Title:

REACTOR TEXT 3.4.2

Title:

REACTOR TEXT 3.4.3

Title:

REACTOR TEXT 3.4.4

Title:

REACTOR 4

04/27/2010 COOLANT SYSTEM (RCS)

RECIRCULATION LOOPS OPERATING 2

04/27/2010 COOLANT SYSTEM (RCS)

JET PUMPS 3

01/13/2012 COOLANT SYSTEM RCS SAFETY RELIEF VALVES S/RVS 0

11/15/2002 COOLANT SYSTEM (RCS)

RCS OPERATIONAL LEAKAGE Page~

of

  • ~

Report Date: 01/16/12 Page 3 of 8

Report Date: 01/16/12

SSSMANU7AL Manual Name:

TSB1 Manual

Title:

TECHNICAL SPECIFICATION BASES UNIT 1.MANUAL TEXT 3.4.5 1

01/16/2006

Title:

REACTOR COOLANT SYSTEM (RCS)

RCS PRESSURE ISOLATION VALVE (PIV) LEAKAGE TEXT 3.4.6 3

01/25/2011

Title:

REACTOR COOLANT SYSTEM (RCS)

RCS LEAKAGE DETECTION INSTRUMENTATION TEXT 3.4.7 2

10/04/2007

Title:

REACTOR COOLANT SYSTEM (RCS)

RCS SPECIFIC ACTIVITY TEXT 3.4. 8

Title:

REACTOR COOLANT HOT SHUTDOWN TEXT 3.4.9

Title:

REACTOR COOLANT COLD SHUTDOWN 1

SYSTEM (RCS) 0 SYSTEM (RCS) 04/18/2005 RESIDUAL HEAT REMOVAL (RHR)

SHUTDOWN COOLING SYSTEM 11/15/2002 RESIDUAL HEAT REMOVAL (RHR)

SHUTDOWN COOLING SYSTEM 04/23/2008 RCS PRESSURE AND TEMPERATURE (P/T) LIMITS TEXT 3.4.10 3

Title:

REACTOR COOLANT SYSTEM (RCS)

TEXT 3.4.11 0

11/15/2002

Title:

REACTOR COOLANT SYSTEM (RCS)

REACTOR STEAM DOME PRESSURE TEXT 3. 5. 1 2

01/16/2006

Title:

EMERGENCY CORE COOLING SYSTEMS (ECCS)

AND REACTOR SYSTEM ECCS -

OPERATING TEXT 3.5.2 0

11/15/2002

Title:

EMERGENCY CORE COOLING SYSTEMS (ECCS)

AND REACTOR SYSTEM ECCS -

SHUTDOWN TEXT 3.5.3 2

07/09/2010

Title:

EMERGENCY CORE COOLING SYSTEMS (ECCS)

AND REACTOR SYSTEM RCIC SYSTEM CORE ISOLATION COOLING (RCIC)

CORE ISOLATION COOLING (RCIC)

CORE ISOLATION COOLING (RCIC)

TEXT 3.6.1.1

Title:

PRIMARY CONTAINMENT 4

11/09/2011 TEXT 3.6.1.2 1

04/23/2008

Title:

CONTAINMENT SYSTEMS PRIMARY CONTAINMENT AIR LOCK Page4 of 8

Report Date: 01/16/12 Page 4 of

.8 Report Date: 01/16/12

SSES MANUAL Manual Name:

TSB1 Manual

Title:

TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.6.1.3 9

04/14/2010

Title:

CONTAINMENT SYSTEMS PRIMARY CONTAINMENT ISOLATION VALVES (PCIVS)

LDCN 3092 TEXT 3.6.1.4 1

04/23/2008

Title:

CONTAINMENT SYSTEMS CONTAINMENT PRESSURE TEXT 3.6.1.5 1

10/05/2005

Title:

CONTAINMENT SYSTEMS DRYWELL AIR TEMPERATURE TEXT 3.6.1.6 0

11/15/2002

Title:

CONTAINMENT SYSTEMS SUPPRESSION CHAMBER-TO-DRYWELL VACUUM BREAKERS TEXT 3.6.2.1 2

04/23/2008

Title:

CONTAINMENT SYSTEMS SUPPRESSION POOL AVERAGE TEMPERATURE TEXT 3.6.2.2 0

11/15/2002

Title:

CONTAINMENT SYSTEMS SUPPRESSION POOL WATER LEVEL TEXT 3.6.2.3 1

01/16/2006

Title:

CONTAINMENT SYSTEMS RESIDUAL HEAT REMOVAL (RHR)

SUPPRESSION POOL COOLING TEXT 3.6.2.4 0

11/15/2002

Title:

CONTAINMENT SYSTEMS RESIDUAL HEAT REMOVAL (RHR)

SUPPRESSION POOL SPRAY TEXT 3.6.3.1 2

06/13/2006

Title:

CONTAINMENT SYSTEMS PRIMARY CONTAINMENT HYDROGEN RECOMBINERS TEXT 3.6.3.2 1

04/18/2005

Title:

CONTAINMENT SYSTEMS DRYWELL AIR FLOW SYSTEM TEXT 3.6.3.3 0

11/15/2002

Title:

CONTAINMENT SYSTEMS PRIMARY CONTAINMENT OXYGEN CONCENTRATION TEXT 3.6.4.1 7

10'/04/2007

Title:

CONTAINMENT SYSTEMS SECONDARY CONTAINMENT Page 5 of 8 Report Date: 01/16/12

SSES MANUAL Manual Name:

TSB1 Manual

Title:

TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.6.4.2 3

03/10/2010

Title:

CONTAINMENT SYSTEMS SECONDARY CONTAINMENT ISOLATION VALVES (SCIVS)

TEXT 3.6.4.3 4

09/21/2006

Title:

CONTAINMENT SYSTEMS STANDBY GAS TREATMENT (SGT)

SYSTEM TEXT 3.7.1

Title:

PLANT SYSTEMS ULTIMATE HEAT 4

04/05/2010 RESIDUAL HEAT REMOVAL SERVICE WATER (RHRSW)

SYSTEM AND THE SINK (UHS)

TEXT 3.7.2

Title:

PLANT TEXT 3.7.3

Title:

PLANT TEXT 3.7.4

Title:

PLANT TEXT 3.7.5

Title:

PLANT TEXT 3.7.6

Title:

PLANT TEXT 3.7.7

Title:

PLANT 2

02/11/2009 SYSTEMS EMERGENCY SERVICE WATER (ESW)

SYSTEM 1

01/08/2010 SYSTEMS CONTROL ROOM EMERGENCY OUTSIDE AIR SUPPLY (CREOAS)

SYSTEM 0

11/15/2002 SYSTEMS CONTROL ROOM FLOOR COOLING SYSTEM 1

10/04/2007 SYSTEMS MAIN CONDENSER OFFGAS 2

04/23/2008 SYSTEMS MAIN TURBINE BYPASS SYSTEM 1

10/04/2007 SYSTEMS SPENT FUEL STORAGE POOL WATER LEVEL TEXT 3.7.8

Title:

PLANT SYSTEMS 0

04/23/2008 TEXT 3.8.1 6

05/06/2009

Title:

ELECTRICAL POWER SYSTEMS AC SOURCES -

OPERATING TEXT 3.8.2 0

11/15/2002

Title:

ELECTRICAL POWER SYSTEMS AC SOURCES -

SHUTDOWN.

Pages of 8

Report Date: 01/16/12 Page 6 of 8

Report Date: 01/16/12

SES MANUAL Manual Name:

TSB1 Manual

Title:

TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.8.3

Title:

ELECTRICAL TEXT 3.8.4

Title:

ELECTRICAL TEXT 3.8.5

Title:

ELECTRICAL TEXT 3.8.6

Title:

ELECTRICAL TEXT 3.8.7

Title:

ELECTRICAL TEXT 3.8.8

Title:

ELECTRICAL 2

04/14/2010 POWER SYSTEMS DIESEL FUEL OIL, LUBE OIL, AND STARTING AIR 3

01/19/2009 POWER SYSTEMS DC SOURCES -

OPERATING 1

12/14/2006 POWER SYSTEMS DC SOURCES -

SHUTDOWN 1

12/14/2006 POWER SYSTEMS BATTERY CELL PARAMETERS 1

10/05/2005 POWER SYSTEMS DISTRIBUTION SYSTEMS OPERATING 0

1i/15/2002 POWER SYSTEMS DISTRIBUTION SYSTEMS SHUTDOWN TEXT 3. 9. 1

Title:

REFUELING TEXT 3.9.2

Title:

REFUELING TEXT 3.9.3

Title:

REFUELING TEXT 3.9.4

Title:

REFUELING TEXT 3.9.5

Title:

REFUELING TEXT 3.9.6

Title:

REFUELING OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS 0

11/15/2002 REFUELING EQUIPMENT INTERLOCKS 1

09/01/2010 REFUEL POSITION ONE-ROD-OUT INTERLOCK 0

11/15/2002 CONTROL ROD POSITION 0

11/15/2002 CONTROL ROD POSITION INDICATION 0

11/15/2002 CONTROL ROD OPERABILITY -

REFUELING 1

10/04/2007 REACTOR PRESSURE VESSEL (RPV)

WATER LEVEL Pagel of 8

Report Date: 01/16/12 Page 7 of 8

Report Date: 01/16/12

SSES MANUAL Manual Name:

TSB1.

Manual

Title:

TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.9.7 0

11/15/2002

Title:

REFUELING OPERATIONS RESIDUAL HEAT REMOVAL (RHR)

HIGH WATER LEVEL TEXT 3.9.8 0

11/15/2002

Title:

REFUELING OPERATIONS RESIDUAL HEAT REMOVAL (RHR)

LOW WATER LEVEL TEXT 3.10.1

Title:

SPECIAL TEXT 3.10.2

Title:

SPECIAL TEXT 3.10.3

Title:

SPECIAL TEXT 3.10.4

Title:

SPECIAL TEXT 3.10.5

Title:

SPECIAL TEXT 3.10.6

Title:

SPECIAL TEXT 3.10.7

Title:

SPECIAL TEXT 3.10.8

Title:

SPECIAL OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS 1

01/23/2008 INSERVICE LEAK AND HYDROSTATIC TESTING OPERATION 0

11/15/2002 REACTOR MODE SWITCH INTERLOCK TESTING' 0

11/15/2002 SINGLE CONTROL ROD WITHDRAWAL HOT SHUTDOWN 0

11/15/2002 SINGLE CONTROL ROD WITHDRAWAL COLD SHUTDOWN 0

11/15/2002 SINGLE CONTROL ROD DRIVE (CRD)

REMOVAL REFUELING 0

11/15/2002 MULTIPLE CONTROL ROD WITHDRAWAL REFUELING 1

04/18/2006 CONTROL ROD TESTING -

OPERATING 1

04/12/2006 SHUTDOWN MARGIN (SDM)

TEST-REFUELING Pae f8RprtDt:0/61 Page 8 of 8

Report Date: 01/16/12

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision TOC Table of Contents 20 B 2.0 SAFETY LIMITS BASES Page B 2.0-1 0

Page TS / B 2.0-2 3

Page TS / B 2.0-3 5

Page TS / B 2.0-4 3

Page TS / B 2.0-5 5

Page TS / B 2.0-6 1

Pages TS / B 2.0-7 through TS / B 2.0-9 1

B 3.0 LCO AND SR APPLICABILITY BASES Page TS / B 3.0-1 1

Pages TS / B 3.0-2 through TS / B 3.0-4 0

Pages TS / B 3.0-5 through TS / B 3.0-7 1

Page TS / B 3.0-8 3

Pages TS / B 3.0-9 through TS / B 3.0-11 2

Page TS / B 3.0-11 a 0

Page TS / B 3.0-12 1

Pages TS / B 3.0-13 through TS / B 3.0-15 2

Pages TS / B 3.0-16 and TS / B 3.0-17 0

B 3.1 REACTIVITY CONTROL BASES Pages B 3.1-1 through B 3.1-4 0

Page TS / B 3.1-5 1

Pages TS / B 3.1-6 and TS / B 3.1-7 2

Pages B 3.1-8 through B 3.1-13 0

Page TS / B 3.1-14 1

Page B 3.1-15 0

Page TS / B 3.1-16 1

Pages B 3.1-17 through B 3.1-19 0

Pages TS / B 3.1-20 and TS / B 3.1-21 1

Page TS / B 3.1-22 0

Page TS / B 3.1-23 1

Page TS / B 3.1-24 0

Pages TS / B 3.1-25 through TS / B 3.1-27 1

Page TS / B 3.1-28 2

Page TS / B 3.1-29 1

Pages B 3.1-30 through B 3.1-33 0

Pages TS / B 3.3-34 through TS / B 3.3-36 1

Pages TS / B 3.1-37 and TS / B 3.1-38 2

Pages TS / B 3.1-39 and TS / B 3.1-40 2

Page TS / B 3.1-40a 0

Pages TS / B 3.1-41 and TS / B 3.1-42 2

SUSQUEHANNA

- UNIT I TSIBLOES-1 Revision 103 SUSQUEHANNA - UNIT 1 TS / B LOES-1 Revision 103

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision Page TS / B 3.1.43 1

Page TS / B 3.1-44 0

Page TS / B 3.1-45 3

Pages TS / B 3.1-46 through TS / B 3.1-49 1

Page TS / B 3.1-50 0

Page TS / B 3.1-51 3

B 3.2 POWER DISTRIBUTION LIMITS BASES Page TS / B 3.2-1 2

Pages TS / B 3.2-2 and TS / B 3.2-3 3

Pages TS / B 3.2-4 and TS / B 3.2-5 2

Page TS / B 3.2-6 3

Page B 3.2-7 1

Pages TS / B 3.2-8 and TS / B 3.2-9 3

Page TS / B 3.2.10 2

Page TS / B 3.2-11 3

Page TS / B 3.2-12 1

Page TS / B 3.2-13 2

B 3.3 INSTRUMENTATION Pages TS /.B 3.3-1 through TS / B 3.3-4 1

Page TS / B 3.3-5 2

Page TS / B 3.3-6 1

Page TS / B 3.3-7 3

Page TS / B 3.3-7a 1

Page TS / B 3.3-8 4

Pages TS / B 3.3-9 through TS / B 3.3-12 3

Pages TS / B 3.3-12a 1

Pages TS / B 3.3-12b and TS / B 3.3-12c 0

Page TS / B 3.3-13 1

Page TS / B 3.3-14 3

Pages TS / B 3.3-15 and TS / B 3.3-16 1

Pages TS / B 3.3-17 and TS / B 3.3-18 4

Page TS / B 3.3-19 1

Pages TS / B 3.3-20 through TS / B 3.3-22 2

Page TS / B 3.3-22a 0

Pages TS / B 3.3-23 and TS / B 3.3-24 2

Pages TS / B 3.3-24a and TS / B 3.3-24b 0

Page TS / B 3.3-25 3

Page TS / B 3.3-26 2

Page TS / B 3.3-27 1

Pages TS / B 3.3-28 through TS / B 3.3-30 3

Page TS / B 3.3-30a 0

SUSQUEHANNA

- UNIT 1 TS/BLOES-2 Revision 103 SUSQUEHANNA - UNIT 1 TS / B LOES-2 Revision 103

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision Page TS / B 3.3-31 4

Page TS / B 3.3-32 5

Pages TS / B 3.3-32a 0

Page TS / B 3.3-32b 1

Page TS I B 3.3-33 5

Page TS I B 3.3-33a 0

Page TS / B 3.3-34 1

Pages TS / B 3.3-35 and TS / B 3.3-36 2

Pages TS / B 3.3-37 and TS / B 3.3-38 1

Page TS / B 3.3-39 2

Pages TS / B 3.3-40 through TS / B 3.3-43 1

Page TS / B 3.3-44 4

Pages TS / B 3.3-44a and TS / B 3.3-44b 0

Page TS / B 3.3-45 3

Pages TS / B 3.3-45a and TS / B 3.3-45b 0

Page TS / B 3.3-46 3

Pages TS / B 3.3-47 2

Pages TS / B 3.3-48 through TS / B 3.3-51 3

Pages TS / B 3.3-52 and TS / B 3.3-53 2

Page TS / B 3-3-53a 0

Page TS / B 3.3-54 4

Page TS / B 3.3-55 2

Pages TS / B 3.3-56 and TS / B 3.3-57 1

Page TS / B 3.3-58 0

Page TS / B 3.3-59 1

Page TS / B 3.3-60 0

Page TS / B 3.3-61 1

Pages TS / B 3.3-62 and TS / B 3.3-63 0

Pages TS / B 3.3-64 and TS / B 3.3-65 2

Page TS / B 3.3-66 4

Page TS / B 3.3-67 3

Page TS / B 3.3-68 4

Page TS / B 3.3-69 5

Pages TS / B 3.3-70 4

Page TS / B 3.3-71 3

Pages TS / B 3.3-72 and TS / B 3.3-73 2

Page TS / B 3.3-74 3

Page TS / B 3.3-75 2

Page TS / B 3.3-75a 6

Page TS / B 3.3-75b 7

Page TS / B 3.3-75c 5

SUSQUEHANNA - UNIT 1 TS / B LOES-3 Revision 103

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision Pages B 3.3-76 through 3.3-77 0

Page TS / B 3.3-78 1

Pages B 3.3-79 through B 3.3-81 0

Page B 3.3-82 1

Page B 3.3-83 0

Pages B 3.3-84 and B 3.3-85 1

Page B 3.3-86 0

Page B 3.3-87 1

Page B 3.3-88 0

Page B 3.3-89 1

Page TS / B 3.3-90 1

Page B 3.3-91 0

Pages TS / B 3.3-92 through TS / B 3.3-100 1

Pages TS / B 3.3-101 through TS / B 3.3-103 0

Page TS / B 3.3-104 2

Pages TS / B 3.3-105 and TS / B 3.3-106 0

Page TS / B 3.3-107 1

Page TS / B 3.3-108 0

Page TS / B 3.3-109 1

Pages TS / B 3.3-110 and TS / B 3.3-111

.0 Pages TS / B 3.3-112 and TS I B 3.3-112a 1

Pages TS / B 3.3-113 through TS / B 3.3-115 1

Page TS / B 3.3-116 3

Page TS / B 3.3-117 1

Pages TS / B 3.3-118 through TS / B 3.3-122 0

Pages TS / B 3.3-123 and TS / B 3.3-124 1

Page TS / B 3.3-124a 0

Page TS / B 3.3-125 0

Pages TS / B 3.3-126 and TS / B 3.3-127 1

Pages TS / B 3.3-128 through TS/ B 3.3-130 0

Page TS / B 3.3-131 1

Pages TS / B 3.3-132 through TS/ B 3.3-134 0

Pages B 3.3-135 through B 3.3-137 0

Page TS / B 3.3-138 1

Pages B 3.3-139 through B 3.3-149 0

Pages TS / B 3.3-150 and TS / B 3.3-151 1

Pages TS / B 3.3-152 through TS/ B 3.3-154 2

Page TS / B 3.3-155 1

Pages TS / B 3.3-156 through TS / B 3.3-158 2

Pages TS / B 3.3-159 through TS I B 3.3-162 1

Page TS / B 3.3-163 2

Pages TS / B 3.3-164 and TS / B 3.3-165 1

Pages TS I B 3.3-166 and TS / B 3.3-167 2

SUSQUEHANNA

- UNIT I TS/BLOES-4 Revision 103 SUSQUEHANNA - UNIT 1 TS / B LOES-4 Revision 103

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision Pages TS / B 3.3-168 and TS / B 3.3-169 1

Page TS / B 3.3-170 2

Pages TS / B 3.3-171 through TS / B 3.3-177 1

Pages TS / B 3.3-178 through TS / B 3.3-179a 2

Pages TS / B 3.3-179b and TS / B 3.3-179c 0

Page TS / B 3.3-180 1

Page TS / B 3.3-181 3

Page TS / B 3.3-182 1

Page TS / B 3.3-183 2

Page TS / B 3.3-184 1

Page TS / B 3.3-185 4

Page TS / B 3.3-186 1

Pages TS / B 3.3-187 and TS / B 3.3-188 2

Pages TS / B 3.3-189 through TS / B 3.3-191 1

Page TS / B 3.3-192 0

Page TS / B 3.3-193 1

Pages TS / B 3.3-194 and TS / B 3.3-195 0

Page TS / B 3.3-196 2

Pages TS / B 3.3-197 through TS / B 3.3-204 0

Page TS / B 3.3-205 1

Pages B 3.3-206 through B 3.3-209 0

Page TS / B 3.3-210 1

Pages B 3.3-211 through B 3.3-219 0

B 3.4 REACTOR COOLANT SYSTEM BASES Pages B 3.4-1 and B 3.4-2 0

Pages TS / B 3.4-3 and Page TS / B 3.4-4 4

Page TS / B 3.4-5 3

Pages TS / B 3.4-6 through TS / B 3.4-9 2

Page TS / B 3.4-10 1

Pages TS / 3.4-11 and TS / B 3.4-12 0

Page TS / B 3.4-13 1

Page TS / B 3.4-14 0

Page TS / B 3.4-15 2

Pages TS / B 3.4-16 and TS / B 3.4-17 4

Page TS / B 3.4-18 2

Pages B 3.4-19 through B 3.4-27 0

Pages TS / B 3.4-28 through TS / B 3.4-30 1

Page TS / B 3.4-31 0

Pages TS / B 3.4-32 and TS / B 3.4-33 1

Page TS / B 3.4-34 0

Pages TS / B 3.4-35 and TS / B 3.4-36 1

Page TS / B 3.4-37 2

Page TS / B 3.4-38 1

SUSQUEHANNA - UNIT 1 TS / B LOES-5 Revision 103

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision Pages B 3.4-39 and B 3.4-40 0

Page TS / B 3.4-41 1

Pages B 3.4-42 through B 3.4-48 0

Page TS / B 3.4-49 3

Page TS / B 3.4-50 1

Page TS / B 3.4-51 3

Page TS / B 3.4-52 2

Page TS / B 3.4-53 1

Pages TS / B 3.4-54 through TS / B 3.4-56 2

Page TS / B 3.4-57 3

Pages TS / B 3.4-58 through TS / B 3.4-60 1

B 3.5 ECCS AND RCIC BASES Pages B 3.5-1 and B 3.5-2 0

Page TS / B 3.5-3 2

Page TS / B 3.5-4 1

Page TS / B 3.5-5 2

Page TS / B 3.5-6 1

Pages B 3.5-7 through B 3.5-10 0

Page TS / B 3.5-11 1

Page TS / B 3.5-12 0

Page TS / B 3.5-13 1

Pages TS / B 3.5-14 and TS / B 3.5-15 0

Pages TS / B 3.5-16 through TS / B 3.5-18 1

Pages B 3.5-19 through B 3.5-24 0

Page TS / B 3.5-25 through TS / B 3.5-27 1

Page TS / B 3.5-28 0

Page TS / B 3.5-29 1

Pages TS / B 3.5-30 and TS / B 3.5-31 0

B 3.6 CONTAINMENT SYSTEMS BASES Page TS/B 3.6-1 2

Page TS / B 3.6-1a 3

Page TS / B 3.6-2 4

Page TS / B 3.6-3 3

Page TS / B 3.6-4 4

Pages TS / B 3.6-5 and TS / B 3.6-6 3

Page TS / B 3.6-6a 2

Page TS / B 3.6-6b 3

Page TS / B 3.6-6c 0

Page B 3.6-7 0

Page B 3.6-8 1

Pages B 3.6-9 through B 3.6-14 0

Page TS / B 3.6-15 2

Page TS / B 3.6-15a 0

Page TS / B 3.6-15b 2

SUSQUEHANNA

- UNIT 1 TSIB LOES-6 Revision 103 SUSQUEHANNA - UNIT 1 TS / B LOES-6 Revision 103

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision Pages TS / B 3.6-16 and TS / B 3.6-17 1

Page TS / B 3.6-17a 0

Pages TS / B 3.6-18 and TS / B 3.6-19 0

Page TS / B 3.6-20 1

Page TS / B 3.6-21 2

Page TS / B 3.6-22 1

Page TS / B 3.6-22a 0

Page TS / B 3.6-23 1

Pages TS / B 3.6-24 and TS / B 3.6-25 0

Pages TS / B 3.6-26 and TS / B 3.6-27 2

Page TS / B 3.6-28 7

Page TS / B 3.6-29 2

Page TS / B 3.6-30 1

Page TS / B 3.6-31 3

Pages TS / B 3.6-32 and TS / B 3.6-33 1

Pages TS / B 3.6-34 and TS / B 3.6-35 0

Page TS / B 3.6-36 1

Page TS / B 3.6-37 0

Page TS / B 3.6-38 3

Page TS / B 3.6-39 2

Page TS / B 3.6-40 6

Page B 3.6-41 1

Pages B 3.6-42 and B 3.6-43 3

Pages TS / B 3.6-44 and TS / B 3.6-45 1

Page TS / B 3.6-46 2

Pages TS / B 3.6-47 through TS / B 3.6-51 1

Page TS / B 3.6-52 2

Pages TS I B 3.6-53 through TS / B 3.6-56 0

Page TS / B 3.6-57 1

Page TS / 3.6-58 2

Pages B 3.6-59 through B 3.6-63 0

Pages TS / B 3.6-64 and TS / B 3.6-65 1

Pages B 3.6-66 through B 3.6-69 0

Pages TS / B 3.6-70 through TS / B 3.6-72 1

Page TS / B 3.6-73 2

Pages TS / B 3.6-74 and TS / B 3.6-75 1

Pages B 3.6-76 and B 3.6-77 0

Page TS / B 3.6-78 1

Pages B 3.6-79 through B 3.3.6-83 0

Page TS / B 3.6-84 3

Page TS I B 3.6-85 2

Page TS / B 3.6-86 4

SUSQUEHANNA

- UNIT 1 TS I B LOES-7 Revision 103 SUSQUEHANNA - UNIT 1 TS / B LOES-7 Revision 103

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision Pages TS / B 3.6-87 through TS / B 3.6-88a 2

Page TS / B 3.6-89 4

Page TS / B 3.6-90 2

Page TS / B 3.6-91 3

Pages TS / B 3.6-92 through TS / B 3.6-96 1

Page TS / B 3.6-97 2

Pages TS / B 3.6-98 and TS / B 3.6-99 1

Page TS / B 3.6-100 3

Page TS / B 3.6-100a 0

Pages TS / B 3.6-101 and TS / B 3.6-102 1

Pages TS I B 3.6-103 and TS / B 3.6-104 2

Page TS / B 3.6-105 3

Page TS / B 3.6-106 2

Page TS / B 3.6-107 3

B 3.7 PLANT SYSTEMS BASES Pages TS / B 3.7-1 3

Page TS / B 3.7-2 4

Pages TS / B 3.7-3 through TS / B 3.7-5 3

Page TS / B 3.7-5a 1

Page TS / B 3.7-6 3

Page TS / B 3.7-6a 2

Page TS / B 3.7-6b 1

Page TS / B 3.7-6c 2

Page TS / B 3.7-7 3

Page TS / B 3.7-8 2

Pages TS / B 3.7-9 through TS / B 3.7-11 1

Pages TS / B 3.7-12 and TS / B 3.7-13 2

Pages TS / B 3.7-14 through TS / B 3.7-18 3

Page TS / B 3.7-18a 1

Pages TS / B 3.7-18b through TS / B 3.7-18e 0

Pages TS / B 3.7-19 through TS / B 3.7-23 1

Page TS / B 3.7-24 1

Pages TS / B 3.7-25 and TS / B 3.7-26 0

Pages TS / B 3.7-27 through TS / B 3.7-29 5

Page TS / B 3.7-30 2

Page TS / B 3.7-31 1

Page TS / B 3.7-32 0

Page TS / B 3.7-33 1

Pages TS / B 3.7-34 through TS / B 3.7-37 0

SUSQUEHANNA

- UNIT 1 TS/B LOES-8 Revision 103 SUSQUEHANNA - UNIT 1 TS / B LOES-8 Revision 103

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision B 3.8 ELECTRICAL POWER SYSTEMS BASES Page TS / B 3.8-1 3

Pages TS / B 3.8-2 and TS / B 3.8-3 2

Page TS / B 3.8-4 3

Pages TS / B 3.8-4a and TS / B 3.8-4b 0

Page TS / B 3.8-5 5

Page TS / B 3.8-6 3

Pages TS / B 3.8-7 through TS/B 3.8-8 2

Page TS / B 3.8-9 4

Page TS / B 3.8-10 3

Pages TS / B 3.8-11 and TS / B 3.8-17 2

Page TS / B 3.8-18 3

Pages TS / B 3.8-19 through TS / B 3.8-21 2

Pages TS / B 3.8-22 and TS / B 3.8-23 3

Pages TS / B 3.8-24 through TS / B 3.8-37 2

Pages B 3.8-38 through B 3.8-44 0

Page TS / B 3.8-45 1

Pages TS / B 3.8-46 through TS / B 3.8-48 0

Pages TS / B 3.8-49 through TS / B 3.8-51 1

Page TS / B 3.8-52 0

Page TS / B 3.8-53 1

Pages TS / B 3.8-54 through TS / B 3.8-57 2

Pages TS / B 3.8-58 through TS / B 3.8-61 3

Pages TS / B 3.8-62 and TS / B 3.8-63 5

Page TS I B 3.8-64 4

Page TS / B 3.8-65 5

Pages TS / B 3.8-66 through TS / B 3.8-77 1

Pages TS / B 3.8-77A through TS / B 3.8-77C 0

Pages B 3.8-78 through B 3.8-80 0

Page TS / B 3.8-81 1

Pages B 3.8-82 through B 3.8-90 0

B 3.9 REFUELING OPERATIONS BASES Pages TS / B 3.9-1 and TS / B 3.9-1a 1

Pages TS / B 3.9-2 through TS / B 3.9-5 1

Pages TS / B 3.9-6 through TS / B 3.9-8 0

Pages B 3.9-9 through B 3.9-18 0

Pages TS / B 3.9-19 through TS / B 3.9-21 1

Pages B 3.9-22 through B 3.9-30 0

SUSQUEHANNA

- UNIT I TS/B LOES-9 Revision 103 SUSQUEHANNA - UNIT 1 TS / B LOES-9 Revision 103

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision B 3.10 SPECIAL OPERATIONS BASES Page TS / B 3.10-1 2

Pages TS / B 3.10-2 through TS / B 3.10-5 1

Pages B 3.10-6 through B 3.10-31 0

Page TS / B 3.10-32 2

Page B 3.10-33 0

Page TS / B 3.10-34 1

Pages B 3.10-35 and B 3.10-36 0

Page TS / B 3.10-37 1

Page TS / B 3.10-38 2

TSB1 Text LOES.doc 1/10/2012 SUSQUEHANNA - UNIT 1SUSQUEHANNA - UNIT 1 TS / B LOES-1 0 Revision 103 TS, / B LOES-1 0 Revision 103

PPL Rev. 3 S/RVs B 3.4.3 B 3.4 REACTOR COOLANT SYSTEM (RCS)

B 3.4.3 Safety/Relief Valves (SIRVs)

BASES BACKGROUND The ASME Boiler and Pressure Vessel Code requires the reactor pressure vessel be protected from overpressure during upset conditi6ns by self-actuated safety valves. As part of the nuclear pressure relief system, the size and number of S/RVs are selected such that peak pressure in the nuclear system will not exceed the ASME Code limits for the reactor coolant pressure boundary (RCPB).

The S/RVs are located on the main steam lines between the reactor vessel and the first isolation valve within the drywell. There are a total of 16 S/RVs of which any 14 are required to be OPERABLE. The S/RVs can actuate by either of two modes: the safety mode or the relief mode. In the safety mode (or spring mode of operation), the valve opens when steam pressure at the valve inlet overcomes the spring force holding the valve closed. This satisfies the Code requirement.

Each S/RV discharges steam through a discharge line to a point below the minimum water level in the suppression pool. Six S/RVs also serve as the Automatic Depressurization System (ADS) valves. The ADS requirements are specified in LCO 3.5.1, "ECCS-Operating."

APPLICABLE SAFETY ANALYSES The overpressure protection system must accommodate the most severe pressurization transient. Evaluations have determined that the most severe transient is the closure of all main steam isolation valves (MSIVs),

followed by reactor scram on high neutron flux (i.e., failure of the direct scram associated with MSIV position) (Ref. 1). For the purpose of the analyses, 14 of the 16 S/RVs are assumed to operate in the safety mode.

The analysis results demonstrate that the design S/RV capacity is capable of maintaining reactor pressure below the ASME Code limit of 110% of vessel design pressure (110% x 1250 psig = 1375 psig). This LCO helps to ensure that the acceptance limit of 1375 psig is met during the Design Basis Event.

(continued)

SUSQUEHANNA - UNIT 1 TS I B 3.4-15 Revision 2

PPL Rev. 3 S/RVs B 3.4.3 BASES APPLICABLE From an overpressure standpoint, the design basis events are bounded SAFETY by the MSIV closure with flux scram event described above. Reference 2 ANALYSES discusses additional events that are expected to actuate the S/RVs.

(continued)

S/RVs satisfy Criterion 3 of the NRC Policy Statement (Ref. 4).

LCO The safety function of 14 of the 16 S/RVs are required to be OPERABLE to satisfy the assumptions of the safety analysis (Refs. 1 and 2). The requirements of this LCO are applicable only to the capability of the S/RVs to mechanically open to relieve excess pressure when the lift setpoint is exceeded (safety function).

The S/RV setpoints are established to ensure that the ASME Code limit on peak reactor pressure is satisfied. The ASME Code specifications require the lowest safety valve setpoint to be at or below vessel design pressure (1250 psig) and the highest safety valve to be set so that the total accumulated pressure does not exceed 110% of the design pressure for overpressurization conditions. The transient evaluations in the FSAR are based on these setpoints, but also include the additional uncertainty of + 3%, - 5% of the nominal setpoint to provide an added degree of conservatism.

Operation with fewer valves OPERABLE than specified, or with setpoints outside the ASME limits, could result in a more severe reactor response to a transient than predicted, possibly resulting in the ASME Code limit on reactor pressure being exceeded.

APPLICABILITY In MODES 1, 2, and 3, all required SIRVs must be OPERABLE, since considerable energy may be in the reactor core and the limiting design basis transients are assumed to occur in these MODES. The S/RVs may be required to provide pressure relief to discharge energy from the core until such time that the Residual Heat Removal (RHR) System is capable of dissipating the core heat.

In MODE 4 reactor pressure is low enough that the overpressure limit is unlikely to be approached by assumed (continued)

SUSQUEHANNA - UNIT 1 TS / B 3.4-16 Revision 4

PPL Rev. 3 S/RVs B 3.4.3 BASES APPLICABILITY operational transients or accidents. In MODE 5, the reactor vessel head is (continued) unbolted or removed and the reactor is at atmospheric pressure. The S/RV function is not needed during these conditions.

ACTIONS A.1 and A.2 With less than the minimum number of required S/RVs OPERABLE, a transient may result in the violation of the ASME Code limit on reactor pressure. If the safety function of one or more required S/RVs is inoperable, the plant must be brought to a MODE in which the LCO does not apply. To achieve this status, the plant must be brought to MODE 3 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and to MODE 4 within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. The allowed Completion Times are reasonable, based on operating experience, to reach required plant conditions from full power conditions in an orderly manner and without challenging plant systems.

SURVEILLANCE SR 3.4.3.1 REQUIREMENT The Surveillance requires that the required S/RVs will open at the pressures assumed in the safety analysis of Reference 1. The demonstration of the S/RV safe lift settings must be performed during shutdown, since this is a bench test, to be done in accordance with the Inservice Testing Program. The lift setting pressure shall correspond to ambient conditions of the valves at nominal operating temperatures and pressures. The S/RV setpoint is + 3%, - 5% of the nominal setpoint for OPERABILITY. Requirements for accelerated testing are established in accordance with the Inservice Test Program. Any of the 16 S/RVs, identified in this Surveillance Requirement, with their associated setpoints, can be designated as the 14 required S/RVs. This maintains the assumptions in the overpressure analysis.

A Note is provided to allow up to two of the required 14 S/RVs to be physically replaced with S/RVs with lower setpoints until the next refueling outage. This provides operational flexibility which maintains the assumptions in the over-pressure analysis.

(continued)

SUSQUEHANNA - UNIT 1 TS / B 3.4-17 Revision 4

PPL Rev. 3 S/RVs B 3.4.3 BASES SURVEILLANCE SR 3.4.3.1 (continued)

REQUIREMENTS The Frequency of this Surveillance is established in accordance with the Inservice Testing Program.

REFERENCES

1. FSAR, Section 5.2.2.1.4.
2. FSAR, Section 15.
3. ASME Operation and Maintenance Code.
4. Final Policy Statement on Technical Specifications Improvements, July 22, 1993 (58 FR 39132).

SUSQUEHANNA - UNIT 1 TS / B 3.4-18 Revision 2

Jan. 16, 2012 Page 1

of 2

MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2012-2515 USER INFORMATION:

GERLACH*ROSE M EMPL#:028401 CA#:

0363 Address: NUCSA2 Phone#:

254-3194 TRANSMITTAL INFORMATION:

TO:

GERLACH*ROSE M 01/16/2012 LOCATION:

NRC REGION 1 TECH SPECS FROM:

NUCLEAR RECORDS DOCUMENT CONTROL CENTER (NUCSA-2)

THE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU.

HARDCOPY USERS MUST ENSURE THE DOCUMENTS PROVIDED MATCH THE INFORMATION ON THIS TRANSMITTAL.

WHEN REPLACING THIS MATERIAL IN YOUR HARDCOPY MANUAL, ENSURE THE UPDATE DOCUMENT ID IS THE SAME DOCUMENT ID.OU'RE REMOVING FROM YOUR MANUAL.

TOOLS FROM THE HUMAN PERFORMANCE TOOL BAG SHOULD:*BE UTILIZED TO ELIMINATE THE CHANCE OF ERRORS.

ATTENTION:

"REPLACE" directions do not affect the Table of Contents, Therefore no TOC will be issued with the updated material.

TS2 -

PP&L SUSQUEHANNA STEAM ELECTRIC STATION TECHNICAL SPECIFICATIONS UNIT 2 MANUAL REMOVE MANUAL TABLE OF CONTENTS ADD MANUAL TABLE OF CONTENTS DATE: 04/20/2011 DATE: 01/13/2012

Jan.

16, 2012 Page 2

of 2

CATEGORY:

DOCUMENTS TYPE:

TS2 ID:

TEXT 3.4.3 ADD:

REV: 2 REMOVE:

REV:1 CATEGORY:

ID:

TEXT REMOVE:

DOCUMENTS TYPE:

TS2 LOES REV:39 ADD:

REV:

40 ANY DISCREPANCIES WITH THE MATERIAL PROVIDED, CONTACT DCS @ X3107 OR X3136 FOR ASSISTANCE.

UPDATES FOR HARDCOPY MANUALS WILL BE DISTRIBUTED WITHIN 3 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.

PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON COMPLETION OF UPDATES.

FOR ELECTRONIC MANUAL

USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.

SSES MANUAL Manual Name:

TS2 Manual

Title:

PP&L SUSQUEHANNA STEAM ELECTRIC STATION TECHNICAL SPECIFICATIONS UNIT 2 MANUK Table Of Contents Issue Date:

0 Procedure Name TEXT LOES

Title:

LIST OF EF

)1/13/2012 Rev 40 FECTIVE SECTIONS Issue Date 01/13/2012 Change ID Change Number TEXT TOC

Title:

TEXT 1.1

Title:

TEXT 1.2

Title:

TEXT 1.3

Title:

TEXT 1.4

Title:

9 01/23/2008 TABLE OF CONTENTS USE AND APPLICATION USE AND APPLICATION USE AND APPLICATION USE AND APPLICATION 3

05/06/2009 DEFINITIONS 0

11/14/2002 LOGICAL CONNECTORS 0

11i4./2002 COMPLETION TIMES 1

01/19/2009 FREQUENCY 4

05/06/2009 TEXT 2.0

Title:

SAFETY LIMITS SLS TEXT 3.0

Title:

2 10/12/2006 FOR OPERATION (LCO)

APPLICABILITY/SURVEILLANCE REQUIREMENT LIMITING CONDITION (SR)

APPLICABILITY TEXT 3.1.1

Title:

REACTIVITY CONTROL TEXT 3.1.2

Title:

REACTIVITY CONTROL 0

11/14/2002 SYSTEMS SHUTDOWN MARGIN SDM 0

11/14/2002 SYSTEMS REACTIVITY ANOMALIES TEXT 3.1.3 1

01/19/2009

Title:

REACTIVITY CONTROL SYSTEMS CONTROL ROD OPERABILITY Pagel of 9

Report Date: 01/16/12 Page I of 9

Report Date: 01/16/12

SSES MANUAL Manual Name:

TS2 Manual

Title:

PP&L SUSQUEHANNA STEAM ELECTRIC STATION TECHNICAL SPECIFICATIONS UNIT 2 MA1 TEXT 3. 1.4

Title:

REACTIVITY TEXT 3.1.5

Title:

REACTIVITY TEXT 3.1.6

Title:

REACTIVITY TEXT 3.1.7

Title:

REACTIVITY TEXT 3.1.8

Title:

REACTIVITY 2

01/30/2009 CONTROL SYSTEMS CONTROL ROD SCRAM TIMES 0

11/14/2002 CONTROL SYSTEMS CONTROL ROD SCRAM ACCUMULATORS 0

11/14/2002 CONTROL SYSTEMS ROD PATTERN CONTROL 3

10/04/2007 CONTROL SYSTEMS STANDBY LIQUID CONTROL (SLC)

SYSTEM 1

10/19/2005 CONTROL SYSTEMS SCRAM DISCHARGE VOLUME (SDV)

VENT AND DRAIN VALVES 1

05/06/2009 TEXT 3.2.1

Title:

POWER DISTRIBUTION LIMITS AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)

TEXT 3.2.2

Title:

POWER DISTRIBUTION 1

05/06/2009 LIMITS MINIMUM CRITICAL POWER RATIO (MCPR)

TEXT 3.2.3 1

05/06/2009

Title:

POWER DISTRIBUTION LIMITS LINEAR HEAT GENERATION RATE (LHGR)

TEXT 3.3.1.1 3

05/06/2009

Title:

INSTRUMENTATION REACTOR PROTECTION SYSTEM RPS INSTRUMENTATION TEXT 3.3.1.2 0

11/14/2002

Title:

INSTRUMENTATION SOURCE RANGE MONITOR (SRM)

INSTRUMENTATION TEXT 3.3.2.1 1

04/09/2007

Title:

INSTRUMENTATION CONTROL ROD BLOCK INSTRUMENTATION TEXT 3.3.2.2 1

05/06/2009

Title:

INSTRUMENTATION FEEDWATER -

MAIN TURBINE HIGH WATER LEVEL TRIP INSTRUMENTATIO W

Page 2 of

.9 Report Date: 01./16/12

SSES MANUAL Manual Name:

TS2 Manual

Title:

PP&L SUSQUEHANNA STEAM ELECTRIC STATION TECHNICAL SPECIFICATIONS UNIT 2 MANUA TEXT 3.3.3.1 2

06/13/2006

Title:

INSTRUMENTATION POST ACCIDENT MONITORING (PAM)

INSTRUMENTATION TEXT 3.3.3.2 1

04/18/2005

Title:

INSTRUMENTATION REMOTE SHUTDOWN SYSTEM TEXT 3.3.4.1 1

05/06/2009

Title:

INSTRUMENTATION END OF CYCLE RECIRCULATION PUMP TRIP (EOC-RPT)

INSTRUMENTATION TEXT 3.3.4.2 0

11/14/2002

Title:

INSTRUMENTATION ANTICIPATED TRANSIENT WITHOUT SCRAM RECIRCULATION PUMP TRIP (ATWS-RPT)

INSTRUMENTATION TEXT 3.3.5.1 4

12/15/2009

Title:

INSTRUMENTATION EMERGENCY CORE COOLING SYSTEM (ECCS)

INSTRUMENTATION TEXT 3.3.5.2

Title:

INSTRUMENTATION 0

11/14/2002 REACTOR CORE ISOLATION COOLING (RCIC)

SYSTEM INSTRUMENTATION TEXT 3.3.6.1 3

05/06/2009

Title:

INSTRUMENTATION PRIMARY CONTAINMENT ISOLATION INSTRUMENTATION TEXT 3.3.6.2 0

11/14/2002

Title:

INSTRUMENTATION SECONDARY CONTAINMENT ISOLATION INSTRUMENTATION TEXT 3.3.7.1

Title:

INSTRUMENTATION INSTRUMENTATION 0

11/14/2002 CONTROL ROOM EMERGENCY OUTSIDE AIR SUPPLY (CREOAS)

SYSTEM TEXT 3.3.8.1 1

03/31/2006

Title:

INSTRUMENTATION LOSS OF POWER (LOP)

INSTRUMENTATION TEXT 3.3.8.2 0

11/14/2002

Title:

INSTRUMENTATION REACTOR PROTECTION SYSTEM (RPS)

ELECTRIC POWER MONITORING TEXT 3.4.1 3

04Q/b9/2007

Title:

REACTOR COOLANT SYSTEM (RCS)

RECIRCULATION LOOPS OPERATING Page3 of

-a Report Date: 01/16/12

SSES MANUAL Manual Name:

TS2 Manual

Title:

PP&L SUSQUEHANNA STEAM ELECTRIC STATION TECHNICAL SPECIFICATIONS UNIT 2 MA*

TEXT 3.4.2

Title:

REACTOR TEXT 3.4.3

Title:

REACTOR TEXT 3.4.4

Title:

REACTOR TEXT 3.4.5

Title:

REACTOR TEXT 3.4.6

Title:

REACTOR TEXT 3.4.7

Title:

REACTOR TEXT 3.4.8

Title:

REACTOR 1

COOLANT SYSTEM (RCS) 2 COOLANT SYSTEM (RCS) 0 COOLANT SYSTEM (RCS) 0 COOLANT SYSTEM (RCS) 1 COOLANT SYSTEM (RCS) 1 COOLANT SYSTEM (RCS) 05/06/2009 JET PUMPS 01/13/2012 SAFETY/RELIEF VALVES (S/RVS) 11/14/2002 RCS OPERATIONAL LEAKAGE 11/14/2002 RCS PRESSURE ISOLATION VALVE (PIV)

LEAKAGE 04/18/2005 RCS LEAKAGE DETECTION INSTRUMENTATION 04/18/2005 RCS SPECIFIC ACTIVITY 1

04/18/2005 COOLANT SYSTEM (RCS)

RESIDUAL HEAT REMOVAL (RHR)

SHUTDOWN COOLING SYSTEM HOT SHUTDOWN TEXT 3.4.9

Title:

REACTOR COOLANT COLD SHUTDOWN TEXT 3.4.10

Title:

REACTOR COOLANT TEXT 3.4.11

Title:

REACTOR COOLANT TEXT 3.5.1 0

SYSTEM (RCS) 11/14/2002 RESIDUAL HEAT REMOVAL (RHR)

SHUTDOWN COOLING SYSTEM 3

05/06/2009 SYSTEM (RCS) RCS PRESSURE AND TEMPERATURE (P/T) LIMITS 0

11/14/2002 SYSTEM (RCS)

REACTOR STEAM DOME PRESSURE 1

04/18/2005

Title:

EMERGENCY CORE COOLING SYSTEMS (ECCS)

AND REACTOR CORE ISOLATION COOLING (RCIC)

SYSTEM ECCS -

OPERATING TEXT 3.5.2 0

11/14/2002

Title:

EMERGENCY CORE COOLING SYSTEMS (ECCS)

AND REACTOR CORE ISOLATION COOLING (RCICW SYSTEM ECCS -

SHUTDOWN

Pae4o, Rpr ae:0/61 Page 4

.of 9 Report Date: 01/16/12

SSES MANUAL Manual Name:

TS2 Manual

Title:

PP&L SUSQUEHANNA STEAM ELECTRIC STATION TECHNICAL SPECIFICATIONS UNIT 2 MANUK TEXT 3.5.3 1

04/18/2005

Title:

EMERGENCY CORE COOLING SYSTEMS (ECCS)

AND REACTOR CORE ISOLATION COOLING (RCIC)

SYSTEM RCIC SYSTEM TEXT 3.6.1.1

Title:

CONTAINMENT TEXT 3.6.1.2

Title:

CONTAINMENT TEXT 3.6.1.3

Title:

CONTAINMENT TEXT 3.6.1.4

Title:

CONTAINMENT TEXT 3.6.1.5

Title:

CONTAINMENT TEXT 3.6.1.6

Title:

CONTAINMENT TEXT 3.6.2.1

Title:

CONTAINMENT TEXT 3.6.2.2

Title:

CONTAINMENT TEXT 3.6.2.3

Title:

CONTAINMENT TEXT 3.6.2.4

Title:

CONTAINMENT TEXT 3.6.3.1

Title:

CONTAINMENT 0

11/14/2002 SYSTEMS PRIMARY CONTAINMENT 0

11/14/2002 SYSTEMS PRIMARY CONTAINMENT AIR LOCK 2

05/06/2009 SYSTEMS PRIMARY CONTAINMENT ISOLATION VALVES (PCIVS) 0 11/14/2002 SYSTEMS CONTAINMENT PRESSURE 0

11/14/2002 SYSTEMS DRYWELL AIR TEMPERATURE 0

11/14/2002 SYSTEMS SUPPRESSION CHAMBER-TO-DRYWELL VACUUM BREAKERS 0

11/14/2002 SYSTEMS SUPPRESSION POOL AVERAGE TEMPERATURE 0

11/14/2002 SYSTEMS SUPPRESSION POOL WATER LEVEL 0

11/14/2002 SYSTEMS RESIDUAL HEAT REMOVAL (RHR)

SUPPRESSION POOL COOLING 0

11/14/2002 SYSTEMS RESIDUAL HEAT REMOVAL (RHR)

SUPPRESSION POOL SPRAY 2

06/13/2006 SYSTEMS PRIMARY CONTAINMENT HYDROGEN RECOMBINERS Page 5.

of 9 Report Date: 01/16/12 Page5 of 9

Report Date: 01/16/12

SSES MANUTAL Manual Name:

TS2 Manual

Title:

PP&L SUSQUEHANNA STEAM ELECTRIC STATION TECHNICAL SPECIFICATIONS UNIT 2 TEXT 3.6.3.2 1

04/18/2005

Title:

CONTAINMENT SYSTEMS DRYWELL AIR FLOW SYSTEM TEXT 3.6.3.3 0

11/14/2002

Title:

CONTAINMENT SYSTEMS PRIMARY CONTAINMENT OXYGEN CONCENTRATION TEXT 3.6.4.1 3

03/16/2006

Title:

CONTAINMENT SYSTEMS SECONDARY CONTAINMENT TEXT 3.6.4.2 0

11/14/2002

Title:

CONTAINMENT SYSTEMS SECONDARY CONTAINMENT ISOLATION VALVES (SCIVS)

TEXT 3.6.4.3 1

10/24/2005

Title:

CONTAINMENT SYSTEMS STANDBY GAS TREATMENT (SGT)

SYSTEM TEXT 3.7.1 1

05/02/2008

Title:

PLANT SYSTEMS RESIDUAL HEAT REMOVAL SERVICE WATER (RHRSW)

SYSTEM AND THE ULTIMATE HEAT SINK (UHS)

TEXT 3.7.2

Title:

PLANT TEXT 3.7.3

Title:

PLANT TEXT 3.7.4

Title:

PLANT TEXT 3.7.5

Title:

PLANT TEXT 3.7.6

Title:

PLANT TEXT 3.7.7

Title:

PLANT 0

11/14/2002 SYSTEMS EMERGENCY SERVICE WATER (ESW)

SYSTEM 1

01/08/2010 SYSTEMS CONTROL ROOM EMERGENCY OUTSIDE AIR SUPPLY (CREOAS)

SYSTEM 0

11/14/2002 SYSTEMS CONTROL ROOM FLOOR COOLING SYSTEM 0

11/14/2002 SYSTEMS MAIN CONDENSER OFFGAS 2

05/06/2009 SYSTEMS MAIN TURBINE BYPASS SYSTEM 0

11/./4/2002 SYSTEMS SPENT FUEL STORAGE POOL WATER LEVEL Page~

of 9

Report Date: 01/16/12 Page 6 of 9

Report.Date: 01/16/12

SSES MANUA-L Manual Name:

TS2 Manual

Title:

PP&L SUSQUEHANNA STEAM ELECTRIC STATION TECHNICAL SPECIFICATIONS UNIT 2 MANUA TEXT 3.7.8 0

05/06/2009

Title:

MAIN TURBINE PRESSURE REGULATION SYSTEM TEXT 3.8.1

Title:

ELECTRICAL TEXT 3.8.2

Title:

ELECTRICAL TEXT 3.8.3

Title:

ELECTRICAL TEXT 3.8.4

Title:

ELECTRICAL TEXT 3.8.5

Title:

ELECTRICAL TEXT 3.8.6

Title:

ELECTRICAL TEXT 3.8.7

Title:

ELECTRICAL TEXT 3.8.8

Title:

ELECTRICAL TEXT 3.9.1 4

02/28/2008 POWER SYSTEMS AC SOURCES -

OPERATING 1

10/05/2005 POWER SYSTEMS AC SOURCES -

SHUTDOWN 0

11/14/2002 POWER SYSTEMS DIESEL FUEL OIL, LUBE OIL, AND STARTING AIR 3

01/19/2009 POWER SYSTEMS DC SOURCES -

OPERATING 1

12/14/2006 POWER SYSTEMS DC SOURCES -

SHUTDOWN 1

12/14/2006 POWER SYSTEMS BATTERY CELL PARAMETERS 2

03/31/2006 POWER SYSTEMS DISTRIBUTION SYSTEMS -

OPERATING 0

11/14/2002 POWER SYSTEMS DISTRIBUTION SYSTEMS -

SHUTDOWN 0

11/14/2002

Title:

REFUELING OPERATIONS REFUELING EQUIPMENT INTERLOCKS TEXT 3.9.2 0

11/14/2002

Title:

REFUELING OPERATIONS REFUEL POSITION ONE-ROD-OUT INTERLOCK TEXT 3.9.3 0

11/14/2002

Title:

REFUELING OPERATIONS CONTROL ROD POSITION Pae f9RprtDt:0/61 Page 7 of 9

Report Date: 01/16/12

SSES MANUJAL Manual Name:

TS2 Manual

Title:

PP&L SUSQUEHANNA STEAM ELECTRIC STATION TECHNICAL SPECIFICATIONS UNIT 2 TEXT 3.9.4

Title:

REFUELING TEXT 3.9.5

Title:

REFUELING TEXT 3.9.6

Title:

REFUELING TEXT 3.9.7

Title:

REFUELING TEXT 3.9.8

Title:

REFUELING TEXT 3.10.1

Title:

SPECIAL 0O TEXT 3.10.2

Title:

SPECIAL 01 TEXT 3.10.3

Title:

SPECIAL 01 TEXT 3.10.4

Title:

SPECIAL 0O TEXT 3.10.5

Title:

SPECIAL 0O TEXT 3.10.6

Title:

SPECIAL 01 TEXT 3.10.7

Title:

SPECIAL 01 OPERATION OPERATION OPERATION OPERATION OPERATIOIN

?ERATIONS

?ERATIONS PERATIONS

?ERATIONS

?ERATIONS PERATIONS PERATIONS 0

11/14/2002 IS CONTROL ROD POSITION INDICATION 0

11/14/2002 IS CONTROL ROD OPERABILITY -

REFUELING 0

11/14/2002 IS REACTOR PRESSURE VESSEL (RPV)

WATER LEVEL 0

11/14/2002 IS RESIDUAL HEAT REMOVAL (RHR)

HIGH WATER LEVEL 0

11/14/2002 IS RESIDUAL HEAT REMOVAL (RHR)

LOW WATER LEVEL 1

01/23/2008 INSERVICE LEAK AND HYDROSTATIC TESTING OPERATION 0

11/14/2002 REACTOR MODE SWITCH INTERLOCK TESTING 0

11/14/2002 SINGLE CONTROL ROD WITHDRAWAL -

HOT SHUTDOWN 0

11/14/2002 SINGLE CONTROL ROD WITHDRAWAL -

COLD SHUTDOWN 0

11/14/2002 SINGLE CONTROL ROD DRIVE (CRD)

REMOVAL -

REFUELING 0

11/14/2002 MULTIPLE CONTROL ROD WITHDRAWAL -

REFUELING 0

114.4/2002 CONTROL ROD TESTING -

OPERATING Pae f9RprtDt:0/61 Page 8 of

.9 Report Date: 01/16/12

SSES MANUAL Manual Name:

TS2 Manual

Title:

PP&L SUSQUEHANNA STEAM ELEC6ýTRIC STATION TECHNICAL SPECIFICATIONS UNIT 2 MANUK TEXT 3.10.8 2

12/15/2009

Title:

SPECIAL OPERATIONS SHUTDOWN MARGIN (SDM)

TEST -

REFUELING TEXT 4.0

Title:

TEXT 5.1

Title:

TEXT 5.2

Title:

TEXT 5.3

Title:

TEXT 5.4

Title:

TEXT 5.5

Title:

TEXT 5.6

Title:

TEXT 5.7

Title:

1 05/24/2007 DESIGN FEATURES ADMINISTRATIVE CONTROLS 1

ADMINISTRATIVE CONTROLS 0

ADMINISTRATIVE CONTROLS 0

ADMINISTRATIVE CONTROLS 11/14/2002 RESPONSIBILITY 10/09/2009 ORGANIZATION 11/14/2002 UNIT STAFF QUALIFICATIONS 11/14/2002 PROCEDURES 5

01/08/2010 CONTROLS PROGRAMS AND MANUALS ADMINISTRATIVE 05/06/2009 REPORTING REQUIREMENTS ADMINISTRATIVE CONTROLS 0

11/14/2002 CONTROLS HIGH RADIATION AREA ADMINISTRATIVE TEXT APPENDIX B 0

11/14/2002

Title:

ENVIRONMENTAL PROTECTION PLAN NON-RADIOLOGICAL Pages of 9 Report Date: 01/16/12 Page 9 of 9

Report Date: 01/16/12

SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 40 LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS)

Section Title Amendment TOC Table of Contents TS/TOC-1 223 TS/TOC-2 211 TS/TOC-3 223 TS/TOC-4 210 1.0 USE AND APPLICATION 1.1 Definitions Page 1.1-1 151 Pages 1.1-2 and 1.1-3 216 Page 1.1-4 151 Page 1.1-5 220 Page 1.1-6 224 Pages 1.1-7 and 1.1-8 151 1.2 Logical Connectors Pages 1.2-1 through 1.2-3 151 1.3 Completion Times Pages 1.3-1 through 1.3-13 151 1.4 Frequency Pages 1.4-1 through 1.4-3 151 Pages TS / 1.4-4 and TS / 1.4-5 229 2.0 SAFETY LIMITS (SLs)

Page TS /2.0-1 230 Pages TS / 2.0-2 and 2.0-3 154 3.0 LIMITING CONDITION FOR OPERATION (LCO) APPLICABILITY/

SURVEILLANCE REQUIREMENT (SR) APPLICABILITY Page TS /3.0-1 213 Page TS / 3.0-2 195 Page TS /3.0-3 213 Page TS /3.0-4 179 Page TS / 3.0-5 195 3.1 REACTIVITY CONTROL SYSTEMS Pages 3.1-1 through 3.1-7 151 Page TS 3.1-8 229 Page 3.1-9 151 Page TS 3.1-10 229 Page 3.1-11 151 SUSQUEHANNA - UNIT 2 TS / LOES-1 Effective Date 01 /10/2012

SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 40 LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS)

Section Title Amendment Page TS /3.1-12 214 Page TS / 3.1-13 228 Pages 3.1-14 through 3.1-19 151 Pages 3.1-20 and 3.1-21 217 Page TS /3.1-22 217 Page 3.1-23 217 Page 3.1-24 151 Page TS / 3.1-25 199 Page 3.1-26 151 3.2 POWER DISTRIBUTION LIMITS Pages 3.2-1 through 3.2-6 224 3.3 INSTRUMENTATION Page 3.3-1 207 Pages 3.3-2 through 3.3-6 224 Pages TS / 3.3-7 and TS / 3.3-8 224 Page 3.3-9 224 Pages 3.3-10 through 3.3-15 151 Page 3.3-16 220 Page 3.3-17 151 Page TS / 3.3-18 220 Page 3.3-19 151 Page TS / 3.3-20 220 Page 3.3-21 224 Page 3.3-22 151 Page TS / 3.3-23 195 Page 3.3-24 151 Pages TS / 3.3-25 and TS I 3.3-26 211 Page TS /3.3-27 195 Pages 3.3-28 and 3.3-29 151 Pages 3.3-30 through 3.3-32 224 Pages TS / 3.3-37 through TS / 3.3-41 155 Page TS / 3.3-42 202 Pages TS / 3.3-43 and TS / 3.3-44 155 Page TS / 3.3-45 234 Pages TS / 3.3-46 and TS / 3.3-47 196 SUSQUEHANNA-UNIT2 TS / LOES-2 Effective Date 01 /10/2012

SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 40 LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS)

Section Title Amendment Pages 3.3-48 through 3.3-51 151 Page TS /3.3-52 188 Pages 3.3-53 through 3.3-55 151 Page TS / 3.3-56 166 Page TS / 3.3-57 224 Pages 3.3-58 through 3.3-60 151 Page 3.3-61 216 Page TS /3.3-62 188 Pages 3.3-63 through 3.3-71 151 Pages TS / 3.3-72 through TS / 3.3-74 208 Pages 3.3-75 through 3.3-77 151 3.4 REACTOR COOLANT SYSTEM (RCS)

Page TS / 3.4-1 207 Pages TS / 3.4-2 through TS / 3.4-5 192 Page 3.4-6 151 Pages 3.4-7 and 3.4-8 224 Page TS / 3.4-9 237 Pages 3.4-10 through 3.4-13 151 Pages TS / 3.4-14 and TS / 3.4-15 195 Page 3.4-16 151 Page TS / 3.4-17 195 Page 3.4-18 151 Page TS / 3.4-19 195 Pages 3.4-20 through 3.4-25 151 Page TS /3.4-26 174 Pages 3.4-27 and 3.4-28 224 Page 3.4-29 151 Pages TS /3.4-30 through TS I 3.4-30b 209 Page 3.4-31 151 3.5 EMERGENCY CORE COOLING SYSTEMS (ECCS) AND REACTOR CORE ISOLATION COOLING (RCIC) SYSTEM Page TS / 3.5-1 195 Pages 3.5-2 through 3.5-11 151 Page TS /3.5-12 195 Pages 3.5-13 and 3.5-14 151 SUSQUEHANNA

- UNIT 2 TS / LOES-3 Effective Date 01/10/2012 SUSQUEHANNA - UNIT 2 TS / LOES-3 Effective Date 01/10/2012

SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 40 LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS)

Section Title Amendment 3.6 CONTAINMENT SYSTEMS Page 3.6-1 151 Page TS / 3.6-2 171 Pages 3.6-3 through 3.6-7 151 Page TS /3.6-8 170 Page 3.6-9 151 Pages TS / 3.6-10 and TS /3.6-11 170 Pages 3.6-12 and 3.6-13 151 Page TS / 3.6-14 200 Page TS / 3.6-15 231 Pages 3.6-16 through 3.6-20 151 Page TS /3.6-21 173 Pages 3.6-22 through 3.6-25 151 Page TS / 3.6-26 181 Pages 3.6-27 through 3.6.29 151 Pages TS / 3.6-30 and TS / 3.6-31 211 Page TS /3.6-32 195 Pages 3.6-33 and 3.6-34 151 Pages TS / 3.6-35 and TS / 3.6-36 203 Page TS / 3.6-37 205 Pages 3.6-38 through 3.6-42 151 Pages TS / 3.6-43 and TS / 3.6-44 203 3.7 PLANT SYSTEMS Page TS / 3.7-1 224 Page TS / 3.7-2 180 Page TS / 3.7-3 224 Pages TS / 3.7-3a through TS / 3.7-3d 224 Pages 3.7-4 and 3.7-5 151 Pages TS / 3.7-6 through TS / 3.7-9 232 Pages 3.7-10 through 3.7-14 151 Page TS / 3.7-15 224 Page TS /3.7-16 193 Page 3.7-17 151 Pages TS / 3.7-18 and TS / 3.7-19 224 3.8 ELECTRICAL POWER SYSTEMS Page TS / 3.8-1 225 Page TS /3.8-2 202 Pages 3.8-3 through 3.8-7 151 Page TS /3.8-8 159 SUSQUEHANNA

- UNIT 2 TS I LOES-4 Effective Date 01/10/2012 SUSQUEHANNA - UNIT 2 TS, / LOES-4 Effective Date 01 /10/2012

SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 40 LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS)

Section Title Amendment Pages 3.8-9 through 3.8-18 151 Page TS / 3.8-19 202 Pages 3.8-20 through 3.8-22 151 Page TS / 3.8-23 157 Page TS / 3.8-24 151 Page TS /3.8-25 157 Pages TS / 3.8-26 and TS / 3.8-26a 227 Page TS / 3.8-27 227 Pages TS / 3.8-28 and TS / 3.8-29 215 Page TS / 3.8-30 227 Pages TS / 3.8-31 through TS / 3.8-33 215 Pages 3.8-34 through 3.8-37 151 Pages TS /3.8-38 through TS /3.8-43 215 Pages TS / 3.8-44 through TS / 3.8-46 208 Pages 3.8-47 through 3.8-53 151 3.9 REFUELING OPERATIONS Pages 3.9-1 through 3.9-15 151 3.10 SPECIAL OPERATIONS Page TS / 3.10-1 223 Pages 3.10-2 through 3.10-19 151 Page TS / 3.10-20 234 Page TS /3.10-21 207 Pages 3.10-22 and 3.10-23 151 4.0 DESIGN FEATURES Page TS / 4.0-1 184 Pages 4.0-2 and 4.0-3 151 Page TS / 4.0-4 221 5.0 ADMINISTRATIVE CONTROLS Pages 5.0-1 and 5.0-2 151 Pages TS / 5.0-3 and TS / 5.0-4 233 Pages 5.0-5 through 5.0-7 151 Page TS / 5.0-8 188 Page TS / 5.0-9 183 Page 5.0-10 151 Page TS / 5.0-11 219 Pages 5.0-12 and 5.0-13 151 SUSQUEHANNA

- UNIT 2 TS / LOES-5 Effective Date 01/10/2012 SUSQUEHANNA - UNIT 2 TS, / LOES-5 Effective Date 01 /10/2012

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS)

PPL Rev. 40 Section Title Amendment Page TS / 5.0-14 Page 5.0-15 Pages TS / 5.0-16 and TS / 5.0-17 Page TS / 5.0-18 Page TS / 5.0-18a Pages TS / 5.0-18b and TS / 5.0-18c Page TS / 5.0-19 Page TS / 5.0-20 Pages TS / 5.0-21 through TS / 5.0-23 Page TS / 5.0-23a Pages TS / 5.0-24 through TS / 5.0-27 Appendix B Environmental Protection Plan TS2 Text LOES 01/10/2012 186 151 183 224 219 232 210 183 224 194 184 162 SUSQUEHANNA - UNIT 2 TS / LOES-6 Effective Date 01 /10/2012

PPL Rev. 2 S/RVs 3.4.3 3.4 REACTOR COOLANT SYSTEM (RCS) 3.4.3 Safety/Relief Valves (S/RVs)

LCO 3.4.3 APPLICABILITY:

The safety function of 14 S/RVs shall be OPERABLE.

MODES 1, 2, and 3.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.1 One or more required A.1 Be in MODE 3.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> S/RVs inoperable.

AND A.2 Be in MODE 4.

36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> SUSQUEHANNA - UNIT 2 3.4-8 Amendment M1, 224

PPL Rev. 2 S/RVs 3.4.3 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY i

SR 3.4.3.1 Verify the safety function lift setpoints of the required S/RVs are as follows:

NOTE -------------------------

Up to two inoperable required S/RVs may be replaced with spare OPERABLE S/RVs having lower setpoints until the next refueling outage.

In accordance with the Inservice Testing Program Number of S/RVs 2

6 8

Setpoint (psig) 1175 (Ž1117 and

  • 1210) 1195 (Ž1136 and *<

1230) 1205 (Ž!

1145 and *<

1241)

Following testing, lift settings shall be within

+/-1%.

SUSQUEHANNA - UNIT 2 TS / 3.4-9 Amendment 475, 237

Jan. 16, 2012 Page 1

of 2

MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2012-2337 USER INFORMATION:

GERLACH*ROSE M EMPL#:028401 CA#:

0363 Address: NUCSA2 Phone#:

254-3194 TRANSMITTAL INFORMATION:

TO:

GERLACH*ROSE M 01/16/2012 LOCATION:

NRC REGION 1 TECH SPECS FROM:

NUCLEAR RECORDS DOCUMENT CONTROL CENTER (NUCSA-2)

THE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU.

HARDCOPY USERS MUST ENSURE THE DOCUMENTS PROVIDED MATCH THE INFORMATION ON THIS TRANSMITTAL.

WHEN REPLACING THIS MATERIAL IN YOUR HARDCOPY MANUAL, ENSURE THE UPDATE DOCUMENT ID IS THE SAME DOCUMENT ID YOU'RE REMOVING FROM YOUR MANUAL.

TOOLS FROM THE HUMAN PERFORMANCE TOOL BAG SHOULD,

'.BAE UTILIZED TO ELIMINATE THE CHANCE OF ERRORS.

ATTENTION:

"REPLACE" directions do not affect the Table of Contents, Therefore no TOC will be issued with the updated material.

TSI -

PP&L SUSQUEHANNA STEAM ELECTRIC STATION TECHNICAL SPECIFICATIONS UNIT 1 MANUAL REMOVE MANUAL TABLE OF CONTENTS ADD MANUAL TABLE OF CONTENTS DATE: 04/20/2011 DATE: 01/13/2012

Jan. 16, 2012 Page 2

of 2

CATEGORY:

DOCUMENTS TYPE: TSI ID:

TEXT 3.4.3 REMOVE:

REV:I ADD:

REV:

2 CATEGORY:

ID:

TEXT REMOVE:

DOCUMENTS TYPE: TS1 LOES REV:35 ADD:

REV:

36 ANY DISCREPANCIES WITH THE MATERIAL PROVIDED, CONTACT DCS @ X3107 OR X3136 FOR ASSISTANCE.

UPDATES FOR HARDCOPY MANUALS WILL BE DISTRIBUTED WITHIN 3 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.

PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON COMPLETION OF UPDATES.

FOR ELECTRONIC MANUAL

USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.

SSES MANUJAL Manual Name:

TS1 Manual

Title:

PP&L SUSQUEHANNA STEAM ELECTRIC STATION TECHNICAL SPECIFICATIONS UNIT 1 MANUK Table Of Contents Issue Date:

0 Procedure Name TEXT LOES

Title:

LIST OF EF

)1/13/2012 FECTIVE SECT Rev Issue Date 36 01/13/2012 IONS 8

01/23/2008 Change ID Change Number TEXT TOC

Title:

TEXT 1.1

Title:

TEXT 1.2

Title:

TEXT 1.3

Title:

TEXT 1.4

Title:

TABLE OF CONTENTS USE AND APPLICATION USE AND APPLICATION USE AND APPLICATION USE AND APPLICATION 2

05/02/2008 DEFINITIONS 0

11/06/2002 LOGICAL CONNECTORS 0

11/06/2002 COMPLETION TIMES 1

01/19/2009 FREQUENCY 4

05/02/2008 TEXT 2.0

Title:

SAFETY LIMITS SLS TEXT 3.0

Title:

2 10/12/2006 FOR OPERATION (LCO) APPLICABILITY/SURVEILLANCE REQUIREMENT LIMITING CONDITION (SR)

APPLICABILITY TEXT 3.1.1 0

11/06/2002

Title:

REACTIVITY CONTROL SYSTEMS SHUTDOWN MARGIN (SDM)

TEXT 3.1.2

Title:

REACTIVITY CONTROL 0

1/i06/2002 SYSTEMS REACTIVITY ANOMALIES TEXT 3.1.3 1

01/19/2009

Title:

REACTIVITY CONTROL SYSTEMS-CONTROL ROD OPERABILITY Pagel of 9 Report Date: 01/16/12 Page 1 of 9

Report Date: 01/16/12

SSES MANUJAL Manual Name:

TS1 Manual

Title:

PP&L SUSQUEHANNA STEAM ELECTRIC STATION TECHNICAL SPECIFICATIONS UNIT 1 TEXT 3.1.4

Title:

REACTIVITY TEXT 3.1.5

Title:

REACTIVITY TEXT 3.1.6

Title:

REACTIVITY TEXT 3.1.7

Title:

REACTIVITY TEXT 3.1.8

Title:

REACTIVITY 2

CONTROL SYSTEMS 0

CONTROL SYSTEMS 01/30/2009 11/06/2002 CONTROL ROD SCRAM ACCUMULATORS 0

11/06/2002 CONTROL SYSTEMS ROD PATTERN CONTROL 3

05/02/2008 CONTROL SYSTEMS STANDBY LIQUID CONTROL (SLC)

SYSTEM 1

10/19/2005 CONTROL SYSTEMS SCRAM DISCHARGE VOLUME (SDV)

VENT AND DRAIN VALVES 1

05/02/2008 TEXT 3.2. 1

Title:

POWER DISTRIBUTION LIMITS AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)

TEXT 3.2.2 1

05/02/2008

Title:

POWER DISTRIBUTION LIMITS MINIMUM CRITICAL POWER RATIO (MCPR)

TEXT 3.2.3 1

05/02/2008

Title:

POWER DISTRIBUTION LIMITS LINEAR HEAT GENERATION RATE (LHGR)

TEXT 3.3.1.1 3

05/02/2008

Title:

INSTRUMENTATION REACTOR PROTECTION SYSTEM (RPS)

INSTRUMENTATION TEXT 3.3.1.2 0

11/06/2002

Title:

INSTRUMENTATION SOURCE RANGE MONITOR (SRM)

INSTRUMENTATION TEXT 3.3.2.1 2

05/02/2008

Title:

INSTRUMENTATION CONTROL ROD BLOCK INSTRUMENTATION TEXT 3.3.2.2 1

05/0.2/2008

Title:

INSTRUMENTATION FEEDWATER MAIN TURBINE HIGH WATER LEVEL TRIP INSTRUMENTATION Page 2 of 9

Report. Date: 01/16/12

SSES MANUAL Manual Name:

TS1 Manual

Title:

PP&L SUSQUEHANNA STEAM ELECTRIC STATION TECHNICAL SPECIFICATIONS UNIT 1 MANUKJ TEXT 3.3.3.1 2

06/13/2006

Title:

INSTRUMENTATION POST ACCIDENT MONITORING (PAM)

INSTRUMENTATION LDCN 2930 TEXT 3.3.3.2 1

04/18/2005

Title:

INSTRUMENTATION REMOTE SHUTDOWN SYSTEM TEXT 3.3.4.1 1

05/02/2008

Title:

INSTRUMENTATION END OF CYCLE RECIRCULATION PUMP TRIP (EOC-RPT)

INSTRUMENTATION TEXT 3.3.4.2 0

11/14/2002

Title:

INSTRUMENTATION ANTICIPATED TRANSIENT WITHOUT SCRAM RECIRCULATION PUMP TRIP (ATWS-RPT)

INSTRUMENTATION TEXT 3.3.5.1 3

12/15/2009

Title:

INSTRUMENTATION EMERGENCY CORE COOLING SYSTEM (ECCS)

INSTRUMENTATION TEXT 3.3.5.2 0

11/14/2002

Title:

INSTRUMENTATION REACTOR CORE ISOLATION COOLING (RCIC)

SYSTEM INSTRUMENTATION TEXT 3.3.6.1 4

05/02/2008

Title:

INSTRUMENTATION PRIMARY CONTAINMENT ISOLATION INSTRUMENTATION TEXT 3.3.6.2 0

11/14/2002

Title:

INSTRUMENTATION SECONDARY CONTAINMENT ISOLATION INSTRUMENTATION TEXT 3.3.7.1 0

11/14/2002

Title:

INSTRUMENTATION CONTROL ROOM EMERGENCY OUTSIDE AIR SUPPLY (CREOAS)

SYSTEM INSTRUMENTATION TEXT 3.3.8.1 0

11/14/2002

Title:

INSTRUMENTATION LOSS OF POWER (LOP)

INSTRUMENTATION TEXT 3.3.8.2 0

11/14/2002

Title:

INSTRUMENTATION REACTOR PROTECTION SYSTEM (RPS)

ELECTRIC POWER MONITORING TEXT 3.4.1

Title:

REACTOR COOLANT 3

03/,.i/2006 SYSTEM (RCS)

RECIRCULATION LOOPS OPERATING Page~

of 9

Report Date: 01/16/12 Page 3 of 9

Report Date: 01/16/12

SSES MANUAL Manual Name:

TS1 Manual

Title:

PP&L SUSQUEHANNA STEAM ELECTRIC STATION TECHNICAL SPECIFICATIONS UNIT 1 TEXT 3.4.2

Title:

REACTOR TEXT 3.4.3

Title:

REACTOR TEXT 3.4.4

Title:

REACTOR TEXT 3.4.5

Title:

REACTOR TEXT 3.4.6

Title:

REACTOR TEXT 3.4.7

Title:

REACTOR 1

COOLANT SYSTEM (RCS) 2 COOLANT SYSTEM (RCS) 05/02/2008 JET PUMPS 01/13/2012 SAFETY/RELIEF VALVES (S/RVS) 0 11/14/2002 COOLANT SYSTEM (RCS)

RCS OPERATIONAL LEAKAGE 0

11/14/2002 COOLANT SYSTEM (RCS)

RCS PRESSURE ISOLATION VALVE (PIV) LEAKAGE 1

04/18/2005 COOLANT SYSTEM (RCS)

RCS LEAKAGE DETECTION INSTRUMENTATION 1

COOLANT SYSTEM (RCS) 04/18/2005 RCS SPECIFIC ACTIVITY TEXT 3.4. 8

Title:

REACTOR COOLANT HOT SHUTDOWN TEXT 3.4.9

Title:

REACTOR COOLANT COLD SHUTDOWN 1

04/18/2005 SYSTEM (RCS)

RESIDUAL HEAT REMOVAL (RHR)

SHUTDOWN COOLING SYSTEM 0

11/14/2002 SYSTEM (RCS)

RESIDUAL HEAT REMOVAL (RHR)

SHUTDOWN COOLING SYSTEM TEXT 3.4.10 2

05/02/2008

Title:

REACTOR COOLANT SYSTEM (RCS)

RCS PRESSURE AND TEMPERATURE (P/T) LIMITS TEXT 3.4.11 0

11/14/2002

Title:

REACTOR COOLANT SYSTEM (RCS)

REACTOR STEAM DOME PRESSURE TEXT 3.5. 1 1

04/18/2005

Title:

EMERGENCY CORE COOLING SYSTEM (ECCS)

AND REACTOR CORE ISOLATION COOLING (RCIC)

SYSTEM ECCS OPERATING TEXT 3.5.2 0

1171,4/2002

Title:

EMERGENCY CORE COOLING SYSTEM (ECCS)

AND REACTOR CORE ISOLATION COOLING SYSTEM ECCS SHUTDOWN (RCIC)@*

Page4 of 9

Report Date: 01/16/12 Page 4 1 of 9

Report Date: 01/16/12

SSES MANUJAL Manual Name:

TS1 Manual

Title:

PP&L SUSQUEHANNA STEAM ELECTRIC STATION TECHNICAL SPECIFICATIONS UNIT 1 MANUK TEXT 3.5.3 1

04/18/2005

Title:

EMERGENCY CORE COOLING SYSTEM (ECCS)

AND REACTOR CORE ISOLATION COOLING (RCIC)

SYSTEM RCIC SYSTEM TEXT 3.6.1.1

Title:

CONTAINMENT TEXT 3.6.1.2

Title:

CONTAINMENT TEXT 3.6.1.3

Title:

CONTAINMENT TEXT 3.6.1.4

Title:

CONTAINMENT TEXT 3.6.1.5

Title:

CONTAINMENT TEXT 3.6.1.6

Title:

CONTAINMENT TEXT 3.6.2.1

Title:

CONTAINMENT TEXT 3.6.2.2

Title:

CONTAINMENT TEXT 3.6.2.3

Title:

CONTAINMENT TEXT 3.6.2.4

Title:

CONTAINMENT TEXT 3.6.3.1

Title:

CONTAINMENT 0

11/14/2002 SYSTEMS PRIMARY CONTAINMENT 0

11/14/2002 SYSTEMS PRIMARY CONTAINMENT AIR LOCK 3

05/06/2009 SYSTEMS PRIMARY CONTAINMENT ISOLATION VALVES (PCIVS) 0 11/14/2002 SYSTEMS CONTAINMENT PRESSURE 0

11/i4/2002 SYSTEMS DRYWELL AIR TEMPERATURE 0

11/14/2002 SYSTEMS SUPPRESSION CHAMBER TO DRYWELL VACUUM BREAKERS 0

11/14/2002 SYSTEMS SUPPRESSION POOL AVERAGE TEMPERATURE 0

11/14/2002 SYSTEMS SUPPRESSION POOL WATER LEVEL 0

11/14/2002 SYSTEMS RESIDUAL HEAT REMOVAL (RHR)

SUPPRESSION POOL COOLING 0

11/14/2002 SYSTEMS RESIDUAL HEAT REMOVAL (RHR)

SUPPRESSION POOL SPRAY 2

Q6/13/2006 SYSTEMS PRIMARY CONTAINMENT HYDROGEN RECOMBINERS Pages of.9.

Report Date: 01/16/12 Page 5 of 9

Report Date: 01/16/12

SSES MANUJAL Manual Name:

TS1 Manual

Title:

PP&L SUSQUEHANNA STEAM ELECTRIC STATION TECHNICAL SPECIFICATIONS UNIT 1 TEXT 3.6.3.2 1

04/18/2005

Title:

CONTAINMENT SYSTEMS DRYWELL AIR FLOW SYSTEM TEXT 3.6.3.3 0

11/14/2002

Title:

CONTAINMENT SYSTEMS PRIMARY CONTAINMENT OXYGEN CONCENTRATION TEXT 3.6.4.1 3

03/16/2006

Title:

CONTAINMENT SYSTEMS SECONDARY CONTAINMENT TEXT 3.6.4.2 0

11/14/2002

Title:

CONTAINMENT SYSTEMS SECONDARY CONTAINMENT ISOLATION VALVES (SCIVS)

TEXT 3.6.4.3 1

10/24/2005

Title:

CONTAINMENT SYSTEMS STANDBY GAS TREATMENT (SGT)

SYSTEM TEXT 3.7.1 1

05/02/2008

.Title: PLANT SYSTEMS RESIDUAL HEAT REMOVAL SERVICE WATER (RHRSW)

SYSTEM AND THE ULTIMATE HEAT SINK (UHS)

TEXT 3.7.2

Title:

PLANT TEXT 3.7.3

Title:

PLANT TEXT 3.7.4

Title:

PLANT TEXT 3.7.5

Title:

PLANT TEXT 3.7.6

Title:

PLANT TEXT 3.7.7

Title:

PLANT 0

11/14/2002 SYSTEMS EMERGENCY SERVICE WATER (ESW)

SYSTEM 1

01/08/2010 SYSTEMS CONTROL ROOM EMERGENCY OUTSIDE AIR SUPPLY (CREOAS)

SYSTEM 0

11/14/2002 SYSTEMS CONTROL ROOM FLOOR COOLING SYSTEM 0

11/14/2002 SYSTEMS MAIN CONDENSER OFFGAS 2

05/02/2008 SYSTEMS MAIN.TURBINE BYPASS SYSTEM 0

11/14/2002 SYSTEMS SPENT FUEL STORAGE POOL WATER LEVEL Page6 of 9 Report Date: 01/16/12 Page 6 of

.9 Report Date: 01/16/12

SSES MANUAL Manual Name:

TS1 Manual

Title:

PP&L SUSQUEHANNA STEAM ELECTRIC STATION TECHNICAL SPECIFICATIONS UNIT 1 MANUA:

TEXT 3.7.8

Title:

EXTENDED POWER UPRATE 0

05/02/2008 TEXT 3. 8.1

Title:

ELECTRICAL TEXT 3.8.2

Title:

ELECTRICAL TEXT 3.8.3

Title:

ELECTRICAL TEXT 3.8.4

Title:

ELECTRICAL TEXT 3.8.5

Title:

ELECTRICAL TEXT 3.8.6

Title:

ELECTRICAL TEXT 3.8.7

Title:

ELECTRICAL TEXT 3.8.8

Title:

ELECTRICAL 4

POWER SYSTEMS 1

POWER SYSTEMS 0

POWER SYSTEMS 05/24/2007 AC SOURCES OPERATING 10/05/2005 AC SOURCES SHUTDOWN 11/14/2002 DIESEL FUEL OIL LUBE LDCN 3586 OIL AND STARTING AIR 3

01/19/2009 POWER SYSTEMS DC SOURCES OPERATING 1

12/14/2006 POWER SYSTEMS DC SOURCES SHUTDOWN 1

12/14/2006 POWER SYSTEMS BATTERY CELL PARAMETERS 1

10/05/2005 POWER SYSTEMS DISTRIBUTION SYSTEMS OPERATING 1

10/05/2005 POWER SYSTEMS DISTRIBUTION SYSTEMS SHUTDOWN TEXT 3.9.1 0

11/14/2002

Title:

REFUELING OPERATIONS REFUELING EQUIPMENT INTERLOCKS TEXT 3.9.2 0

11/14/2002

Title:

REFUELING OPERATIONS REFUEL POSITION ONE ROD OUT INTERLOCK TEXT 3.9.3 0

11/1,4/2002

Title:

REFUELING OPERATIONS CONTROL ROD POSITION Page 7 of ~

Report Date: 01/16/12 Page 7 of 9

Report Date: 01/16/12

SSES MANUAL Manual Name:

TS1 Manual

Title:

PP&LSUSQUEHANNA STEAM ELECTRIC STATION TECHNICAL SPECIFICATIONS UNIT 1 TEXT 3.9.4

Title:

REFUELING TEXT 3,9.5

Title:

REFUELING TEXT 3,9.6

Title:

REFUELING TEXT 3.9.7

Title:

REFUELING TEXT 3.9.8

Title:

REFUELING TEXT 3.10.1

Title:

SPECIAL 0O TEXT 3.10.2

Title:

SPECIAL 01 TEXT 3.10.3

Title:

SPECIAL 0O TEXT 3.10.4

Title:

SPECIAL 01 TEXT 3.10.5

Title:

SPECIAL 01 TEXT 3.10.6

Title:

SPECIAL 01 TEXT 3.10.7

Title:

SPECIAL 0O OPERATIONS OPERATION, OPERATION OPERATION OPERATION

?ERATIONS

?ERATIONS

?ERATIONS PERATIONS

?ERATIONS

?ERATIONS

?ERATIONS 0

11/14/2002 IS CONTROL ROD POSITION INDICATION 0

11/14/2002 IS CONTROL ROD OPERABILITY REFUELING 0

11/14/2002 IS REACTOR PRESSURE VESSEL (RPV) WATER LEVEL 0

11/14/2002 IS RESIDUAL HEAT REMOVAL (RHR)

HIGH WATER LEVEL 0

11/14/2002

.S RESIDUAL HEAT REMOVAL (RHR)

LOW WATER LEVEL 1

01/23/2008 INSERVICE LEAK AND HYDROSTATIC TESTING OPERATION 0

11/14/2002 REACTOR MODE SWITCH INTERLOCK TESTING 0

11/14/2002 SINGLE CONTROL ROD WITHDRAWAL HOT SHUTDOWN 0

11/14/2002 SINGLE CONTROL ROD WITHDRAWAL COLD SHUTDOWN 0

11/14/2002 SINGLE CONTROL ROD DRIVE (CRD)

REMOVAL REFUELING 0

11/14/2002 MULTIPLE CONTROL ROD WITHDRAWAL REFUELING 0

1:1'./14/2002 CONTROL ROD TESTING OPERATING Page~

of 9 Report Date: 01/16/12 Page 8 of 9

Report Date: 01/16/12

SSES MANUAL Manual Name:

TS1 Manual

Title:

PP&L SUSQUEHANNA STEAM ELECTRIC STATION TECHNICAL SPECIFICATIONS UNIT 1 MANUA TEXT 3.10.

Title:

TEXT 4.0

Title:

TEXT 5.1

Title:

TEXT 5.2

Title:

TEXT 5.3

Title:

TEXT 5.4

Title:

TEXT 5.5

Title:

TEXT 5.6

Title:

TEXT 5.7

Title:

.8 2

12/15/2009 SPECIAL OPERATIONS SHUTDOWN MARGIN (SDM)

TEST REFUELING 2

05/24/2007 DESIGN FEATURES ADMINISTRATIVE ADMINISTRATIVE ADMINISTRATIVE ADMINISTRATIVE ADMINISTRATIVE 0

11/14/2002 CONTROLS RESPONSIBILITY 1

10/09/2009 CONTROLS ORGANIZATION 0

11/14/2002 CONTROLS UNIT STAFF QUALIFICATIONS 0

CONTROLS 5

CONTROLS 11/14/2002 PROCEDURES 01/08/2010 PROGRAMS AND MANUALS 7

05/02/2008 ADMINISTRATIVE CONTROLS REPORTING REQUIREMENTS 0

11/14/2002 ADMINISTRATIVE CONTROLS HIGH RADIATION AREA TEXT APPENDIX B 0

11/14/2002

Title:

ENVIRONMENTAL PROTECTION PLAN NON RADIOLOGICAL Pages of 9 Report Date: 01/16/12 Page 9 of 9

Report Date: 01/16/12

SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 36 LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS)

Section Title Amendment TOC Table of Contents TS/TOC-1 242 TS/TOC-2 234 TS/TOC-3 245 TS/TOC-4 233 1.0 USE AND APPLICATION 1.1 Definitions Page 1.1-1 178 Pages 1.1-2 and 1.1-3 239 Page 1.1-4 178 Page 1.1-5 242 Page 1.1-6 246 Pages 1.1-7 and 1.1-8 178 1.2 Logical Connectors Pages 1.2-1 through 1.2-3 178 1.3 Completion Times Pages 1.3-1 through 1.3-13 178 1.4 Frequency Pages 1.4-1 through 1.4-3 178 Pages TS / 1.4-4 and TS / 1.4-5 250 2.0 SAFETY LIMITS (SLs)

Page TS / 2.0-1 246 Pages 2.0-2 and 2.0-3 186 3.0 LIMITING CONDITION FOR OPERATION (LCO) APPLICABILITY/

SURVEILLANCE REQUIREMENT (SR) APPLICABILITY Page TS / 3.0-1 236 Page TS / 3.0-2 219 Page TS / 3.0-3 236 Page TS / 3.0-4 205 Page TS / 3.0-5 219 3.1 REACTIVITY CONTROL SYSTEMS Pages 3.1-1 through 3.1-7 178 Page TS / 3.1-8 250 Page 3.1-9 178 Page TS / 3.1-10 250 Page 3.1-11 178 SUSQUEHANNA - UNIT 1 TS / LOES-1 Effective Date 01 A 0/2012

SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 36 LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS)

Section Title Amendment Page TS /3.1-12 237 Page TS /3.1-13 249 Pages 3.1-14 through 3.1-19 178 Pages 3.1-20 and 3.1-21 240 Page TS / 3.1-22 240 Page 3.1-23 240 Page 3.1-24 178 Page TS / 3.1-25 222 Page 3.1-26 178 3.2 POWER DISTRIBUTION LIMITS Pages 3.2-1 through 3.2-6 246 3.3 INSTRUMENTATION Page TS / 3.3-1 230 Pages TS 1 3.3-2 and TS / 3.3-3 246 Page 3.3-4 178 Pages TS / 3.3-5 through TS /3.3-9 246 Pages 3.3-10 through 3.3-15 178 Page 3.3-16 242 Page 3.3-17 178 Page TS / 3.3-18 through TS / 3.3-20 242 Page 3.3-21 246 Page 3.3-22 178 Page TS /3.3-23 219 Pages TS / 3.3-24 and TS / 3.3-25 234 Page TS /3.3-26 219 Pages 3.3-27 and 3.3-28 178 Pages 3.3-29 through 3.3-31 246 Pages 3.3-32 through 3.3-40 178 Page TS / 3.3-41 225 Pages TS / 3.3-42 and TS / 3.3-43 181 Page TS / 3.3-44 254 Page TS 1 3.3-45 204 Pages TS / 3.3-46 and TS / 3.3-47 220 Pages 3.3-48 through 3.3-51 178 Page TS / 3.3-52 213 Pages 3.3-53 through 3.3-55 178 Page TS / 3.3-56 191 SUSQUEHANNA

- UNIT 1 TS / LOES-2 Effective Date 01/10/2012 SUSQUEHANNA - UNIT 1 TS / LOES-2 Effective Date 01 /10/2012

SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 36 LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS)

Section Title Amendment Page TS / 3.3-57 246 Pages 3.3-58 through 3.3-60 178 Page 3.3-61 239 Page TS /3.3-62 213 Pages 3.3-63 through 3.3-77 178 3.4 REACTOR COOLANT SYSTEM (RCS)

Page TS 1 3.4-1 230 Pages TS / 3.4-2 through TS / 3.4-5 217 Page 3.4-6 178 Pages 3.4-7 and 3.4-8 246 Page TS / 3.4-9 257 Pages 3.4-10 through 3.4-13 178 Pages TS / 3.4-14 and TS / 3.4-15 219 Page 3-4-16 178 Page TS / 3.4-17 219 Page 3.4-18 178 Page TS /3.4-19 219 Pages 3.4-20 through 3.4-25 178 Page TS / 3.4-26 200 Pages 3.4-27 and 3.4-28 246-Page TS /3.4-29 178 Pages TS / 3.4-30 through TS / 3.4-30b 232 Page 3.4-31 178 3.5 EMERGENCY CORE COOLING SYSTEMS (ECCS) AND REACTOR CORE ISOLATION COOLING (RCIC) SYSTEM Page TS / 3.5-1 219 Pages 3.5-2 through 3.5-11 178 Page TS / 3.5-12 219 Pages 3.5-13 and 3.5-14 178 3.6 CONTAINMENT SYSTEMS Pages 3.6-1 through 3.6-7 178 Page TS / 3.6-8 195 Page TS /3.6-9 178 Pages TS /3.6-10 and TS / 3.6-11 195 Pages TS /3.6-12 and TS / 3.6-13 178 Page TS / 3.6-14 223 Page TS / 3.6-15 251 Pages 3.6-16 through 3.6-20 178 SUSQUEHANNA

- UNIT I TS/LOES-3 Effective Date 01/10/2012 SUSQUEHANNA - UNIT 1 TS / LOES-3 Effective Date 01/10/2012

SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 36 LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS)

Section Title Amendment Page TS / 3.6-21 198 Pages 3.6-22 through 3.6-25 178 Page TS / 3.6-26 207 Pages 3.6-27 through 3.6-29 178 Pages TS / 3.6-30 and TS / 3.6-31 234 Page TS / 3.6-32 219 Pages 3.6-33 and 3.6-34 178 Pages TS / 3.6-35 and TS / 3.6-36 226 Page TS / 3.6-37 229 Pages 3.6-38 through 3.6-42 178 Pages TS / 3.6-43 and TS / 3.6-44 226 3.7 PLANT SYSTEMS Page TS /3.7-1 246 Page TS / 3.7-2 206 Page TS / 3.7-3 246 Pages TS / 3.7-3a through TS / 3.7-3d 246 Pages 3.7-4 and 3.7-5 178 Pages TS / 3.7-6 through TS /3.7-9 252 Pages 3.7-10 through 3.7-14 178 Page TS / 3.7-15 246 Page TS / 3.7-16 218 Page 3.7-17 178 Pages 3.7-18 and TS / 3.7-19 246 3.8 ELECTRICAL POWER SYSTEMS Page TS / 3.8-1 219 Page TS / 3.8-2 225 Page TS / 3.8-3 243 Page TS / 3.8-4 214 Page 3.8-5 178 Page TS /.3.8-6 185 Pages 3.8-7 through 3.8-16 178 Page TS / 3.8-17 225 Pages 3.8-18 and 3.8-19 178 Page TS / 3.8-20 183 Page TS / 3.8-21 178 Page TS / 3.8-22 183 Pages TS / 3.8-23 and TS / 3.8-23a 248 Page TS / 3.8-24 248 Page TS / 3.8-25 238 SUSQUEHANNA

- UNIT I TS / LOES-4 Effective Date 01 /1 0/2012 SUSQUEHANNA - UNIT 1.

TS / LOES-4 Effective Date 01 /10/2012

SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 36 LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS)

Section Title Amendment Page TS / 3.8-26 248 Pages TS / 3.8-27 and TS / 3.8-28 238 Pages 3.8-29 and 3.8-30 178 Pages TS / 3.8-31 through TS / 3.8-36 238 Page TS / 3.8-37 225 Pages 3.8-38 through 3.8-40 178 Page TS / 3.8-41 225 Pages 3.8-42 and 3.8-43 178 3.9 REFUELING OPERATIONS Pages 3.9-1 through 3.9-15 178 3.10 SPECIAL OPERATIONS Page TS /3.10-1 245 Pages 3.10-2 through 3.10-19 178 Page TS / 3.10-20 254 Page TS / 3.10-21 230 Pages 3.10-22 and 3.10-23 178 4.0 DESIGN FEATURES Page TS / 4.0-1 216 Pages 4.0-2 and 4.0-3 178 Page TS / 4.0-4 243 5.0 ADMINISTRATIVE CONTROLS Pages 5.0-1 and 5.0-2 178 Pages TS / 5.0-3 and TS / 5.0-4 253 Pages 5.0-5 through 5.0-7 178 Page TS / 5.0-8 212 Page TS / 5.0-9 209 Page 5.0-10 178 Page TS / 5.0-11 241 Pages 5.0-12 and 5.0-13 178 Page TS / 5.0-14 211 Page 5.0-15 178 Pages TS /5.0-16 and TS / 5.0-17 209 Page TS / 5.0-18 246 Page TS / 5.0-18A 241 Pages TS / 5.0-18B and TS / 5.0-18C 252 Page TS / 5.0-19 233 SUSQUEHANNA

- UNIT I TS / LOES-5 Effective Date 01/10/2012 SUSQUEHANNA - UNIT 1 TS / LOES-5 Effective Date 01/10/2012

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS)

PPL Rev. 36 Section Title Amendment Page TS / 5.0-20 Page TS / 5.0-21 through TS / 5.0-23 Page TS / 5.0-24 Page TS / 5.0-25 Pages 5.0-26 through 5.0-30 Appendix B Environmental Protection Plan 209 246 209 186 178 188 TSlText LOES 1/10/2012 SUSQUEHANNA

- UNIT I TSILOES-6 Effective Date 01/1 0/2012 SUSQUEHANNA - UNIT I TS / LOES-6 Effective Date 01 /10/2012

PPL Rev. 2 S/RVs 3.4.3 3.4 3.4.3 LCO 3 APPLIC ACTIOI REACTOR COOLANT SYSTEM (RCS)

Safety/Relief Valves (S/RVs)

.4.3 The safety function of 14 S/RVs shall be OPERABLE.

'ABILITY:

MODES 1, 2, and 3.

CONDITION REQUIRED ACTION COMPLETION TIME A.1 One or more required A.1 Be in MODE 3.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> S/RVs inoperable.

AND A.2 Be in MODE 4.

36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> SUSQUEHANNA - UNIT 1 3.4-8 Amendment IX, 246

PPL Rev. 2 S/RVs 3.4.3 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.4.3.1 Verify the safety function lift setpoints of the required SIRVs are as follows:


NOTE Up to two inoperable required S/RVs may be replaced with spare OPERABLE S/RVs having lower setpoints until the next refueling outage.

In accordance with the Inservice Testing Program Number of S/RVs 2

6 8

Setpoint (Psiq) 1175 (Ž1117 and*_< 1210) 1195 (Ž1136 and

  • 1230) 1205 (Ž1145 and < 1241)

Following testing, lift settings shall be within

+/-1%.

SUSQUEHANNA - UNIT 1 TS / 3.4-9 Amendment 294, 257