ML110490540

From kanterella
Jump to navigation Jump to search

Correction of Typographical Error in Safety Evaluation Report Related to License Renewal
ML110490540
Person / Time
Site: Palo Verde  
Issue date: 03/03/2011
From: Lisa Regner
License Renewal Projects Branch 2
To: Edington R
Arizona Public Service Co
Regner L M, NRR/DLR, 415-1906
References
Download: ML110490540 (3)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 March 3, 2011 Mr. Randall K. Edington Executive Vice President Nuclear!

Chief Nuclear Officer Mail Station 7602 Arizona Public Service Company P.O. Box 52034 Phoenix, AZ 85072-2034

SUBJECT:

PALO VERDE NUCLEAR GENERATING STATION, UNITS 1,2, AND 3 CORRECTION OF TYPOGRAPHICAL ERROR IN SAFETY EVALUATION REPORT RELATED TO LICENSE RENEWAL (TAC NOS. ME0254, ME0255 AND ME0256)

Dear Mr. Edington:

By letter dated December 11,2008, as supplemented by letter dated April 14, 2009, Arizona Public Service Company submitted an application pursuant to Title 10 of the Code of Federal Regulations, Part 54, to renew Operating License Nos. NPF-41, NPF-51, and NPF-74 for the Palo Verde Nuclear Generating Station, Units 1, 2, and 3, respectively. On January 11, 2011, the staff issued the "Safety Evaluation Report Related to License Renewal of Palo Verde Nuclear Generating Station, Units 1, 2, and 3" (SER).

On page 4-29 of the SER, an editorial error was made where the operating-basis earthquake (OBE) stress and the ground-motion range lower stress were reversed. The second paragraph in SER Section 4.3.1.3.1 should read:

The applicant states that for design purposes, the safe-shutdown earthquake (SSE) is based on a 0.20 gravity ground-motion stress, and the OBE is based on a 0.10 gravity ground-motion stress. The applicant states that for the purposes of evaluating actual earthquake events, an SSE is defined as an earthquake that results in a categorization of eight on a Mercalli intensity scale seven (i.e., results in ground-motion ranging stresses ranging from 0.15 gravity to 0.33 gravity). An OBE is defined as an earthquake that results in a categorization of seven on a Mercalli intensity scale (I.e., results in ground-motion stresses ranging from 0.072 gravity to 0.15 gravity). The applicant summarizes that, as of 2008, only seven minor earthquakes have occurred and that the strongest of these earthquakes resulted in ground-motion stresses of only approximately 0.015 gravity. The applicant states that there have not been any recorded SSE or OBE events to date. [emphasis added]

R. Edington

- 2 This editorial error only affected the specified page of the SER and does not change the U.S. Nuclear Regulatory Commission staff's conclusions regarding the license renewal application.

Sincerely, Lisa M. Regner, Senior Project Manager Projects Branch 2 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-528, 50-529, and 50-530 cc: Distribution via Listserv

R. Edington

- 2 This editorial error only affected the specified page of the SER and does not change the U.S. Nuclear Regulatory Commission staffs conclusions regarding the license renewal application.

Docket Nos. 50-528, 50-529, and 50-530 cc: Distribution via Listserv DISTRIBUTION:

HARD COPY:

DLRRF E-MAIL:

PUBLIC RidsNrrDlr Resource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RidsNrrDlrRarb Resource RidsNrrDlrRasb Resource RidsNrrDlrRapb Resource RidsNrrDlrRpob Resource RidsNrrDciCvib Resource RidsNrrDciCpnb Resource RidsNrrDciCsgb Resource RidsNrrDraAfpb Resource ADAMS Accession No. ML110490540 Sincerely, IRA!

Lisa M. Regner, Senior Project Manager Projects Branch 2 Division of License Renewal Office of Nuclear Reactor Regulation RidsNrrDraApla Resource RidsNrrDeEmcb Resource RidsNrrDeEeeb Resource RidsNrrDssSrxb Resource RidsNrrDssSbpb Resource RidsNrrDssScvb Resource RidsOgcMailCenter Resource RidsOpaMail Resource L. Regner D. Drucker R. Hall B. Mizuno, OGC J. H. Bashore, RIV G. Pick, RIV PB2:DLR OFFICE PM:RPB2:DLR

DLR PM:RPB2:DLR NAME LRegner SFigueroa DWrona LRegner 3/1/11 3/1/11 3/3/11 11 OFFICIAL AGENCY RECORD