ML102010290

From kanterella
Jump to navigation Jump to search
Inservice Testing Program Description: Safety-Related Seismic Restraints (Snubbers) for the Third 10-Year Interval
ML102010290
Person / Time
Site: South Texas  
Issue date: 07/13/2010
From: Ruvalcaba M
South Texas
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NOC-AE-10002565
Download: ML102010290 (2)


Text

Nuclear Operating Company South Texas Proect Electric Generating Station P0. Box 289 Wadsworth, Texas 77483 July 13, 2010 NOC-AE-10002565 File No.: G25 10 CFR 50.55a U. S. Nuclear Regulatory Commission Attention: Document Control Desk One White Flint North 11555 Rockville Pike Rockville, MD 20852 South Texas Project Units 1 & 2 Docket Nos. STN 50-498, STN 50-499 Inservice Testing Program

Description:

Safety-Related Seismic Restraints (Snubbers) for the Third 10-Year Interval Pursuant to 10 CFR 50.55a(g), STP Nuclear Operating Company (S,-PNOC) has updated the South Texas Project Inservice Testing (IST) snubber program for the third 10-year interval applicable to safety-related seismic restraints (snubbers) as described in Technical Requirements Manual Section 3/4.7.9.

The IST snubber program plan describes the programmatic aspects for snubber inservice testing to be implemented with the third 10-year interval beginning September 25, 2010.

The IST snubber program plan has been developed in accordance with the requirements of the 2004 Edition, No Addenda, of the ASME OM Code, Subsections ISTA and ISTD with the inspection requirements of Code Case OMN-13, revision 0. The IST snubber program plan complies with the limitations and modifications to these requirements as stated in 10 CFR 50.55a(b) related to implementation of the 2004 ASME OM Code. Therefore, NRC approval is not required prior to implementation.

There are no commitments included with this submittal.

If there are any questions, please contact either Mr. P. L. Walker at (361) 972-8392 or me at (361) 972-7904.

Marco Ruvalcaba

Manager, Testing and Programs Engineering PLW STI: 32689353

NOC-AE-1 0002565 Page 2 of 2 cc:

(paper copy)

(electronic copy)

Regional Administrator, Region IV U. S. Nuclear Regulatory Commission 612 East Lamar Blvd., Suite 400 Arlington, Texas 76011-8064 Mohan C. Thadani Senior Project Manager U.S. Nuclear Regulatory Commission One White Flint North (MS 8B1A) 11555 Rockville Pike Rockville, MD 20852 Senior Resident Inspector U. S. Nuclear Regulatory Commission P. 0. Box 289, Mail Code: MN1 16 Wadsworth, TX 77483 C. M. Canady City of Austin Electric Utility Department 721 Barton Springs Road Austin, TX 78704 John Ragan Catherine Callaway Jim von Suskil NRG South Texas LP A. H. Gutterman, Esquire Morgan, Lewis & Bockius LLP Mohan C. Thadani U. S. Nuclear Regulatory Commission Richard Pena E. Alarcon Kevin Polio City Public Service C. Mele City of Austin Jon C. Wood Cox Smith Matthews Richard A. Ratliff Texas Department of State Health Services Alice Rogers Texas Department of State Health Services