L-10-130, Remainder of Responses to NRC Staff Request for Additional Information Regarding Unit 2 Spent Fuel Pool Rerack Criticality Analyses

From kanterella
(Redirected from ML101610118)
Jump to navigation Jump to search

Remainder of Responses to NRC Staff Request for Additional Information Regarding Unit 2 Spent Fuel Pool Rerack Criticality Analyses
ML101610118
Person / Time
Site: Beaver Valley
(NPF-073)
Issue date: 06/01/2010
From: Harden P
FirstEnergy Nuclear Operating Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-10-130, TAC ME1079
Download: ML101610118 (51)


Text

V Withhold from Public Disclosure under 10CFR2.390 FENOC

'When'separated from Attachment 1, the remainder FirstEnergyof this submittal may be decontrolled.

P.O. Box 4 Shippingport, PA 15077 Paul A. Harden 724-682-5234 Site Vice President Fax: 724-643-8069 June 1, 2010 L-10-130 10 CFR 2.390 and 50.90 ATTN: Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555-0001

SUBJECT:

Beaver Valley Power Station, Unit No. 2 Docket No. 50-412, License No. NPF-73 Remainder of Responses to NRC Staff Request for Additional Information Reqardinq Unit 2 Spent Fuel Pool Rerack Criticality Analyses (TAC No. ME1079)

A license amendment request to revise the Beaver Valley Power Station Unit 2 Technical Specifications to support installation of high density fuel storage racks in the Unit 2 spent fuel pool was submitted on April 9, 2009 (Accession No. ML091210251),

and supplemented on June 15, 2009 (Accession No. ML091680614). With respect to the supporting criticality analysis for the amendment, the Nuclear Regulatory Commission (NRC) staff provided a request for additional information (RAI) by a letter dated February 16, 2010. Responses to a majority of the criticality analysis RAI items were provided in a letter dated March 18, 2010 (Accession No. ML100820165).

Responses to the remaining RAI items are provided in Attachment 1. A portion of the information in the responses is considered proprietary, therefore a nonproprietary version of the responses is provided in Attachment 2. Pursuant to 10 CFR 2.390, an affidavit from Holtec International, the owner of the information that is sought to be withheld from several of the responses, is provided as an enclosure to this letter.

Future correspondence will provide appropriate supplements to the license amendment request, as noted in the attachments.

There are no new regulatory commitments contained in this submittal. If there are any questions or if additional information is required, please contact Mr. Thomas A. Lentz, Manager - Fleet Licensing, at (330) 761-6071.

I declare under penalty of perjury that the foregoing is true and correct. Executed on June /

2010.

Paul A. Harden

Beaver Valley Power Station, Unit No. 2 L-10-130 Page 2 Attachments:

1. Response to RAI on Unit 2 Spent Fuel Pool Rerack Criticality Analysis

[PROPRIETARY VERSION OF THE RESPONSE]

2. Response to RAI on Unit 2 Spent Fuel Pool Rerack Criticality Analysis

[NONPROPRIETARY VERSION OF THE RESPONSE]

Enclosure:

10 CFR 2.390 Proprietary Affidavit from Holtec International cc: NRC Region I Administrator NRC Resident Inspector Office NRC Project Manager Director BRP/DEP Site Representative (BRP/DEP)

Enclosure L-1 0-130 10 CFR 2.390 Proprietary Affidavit from Holtec International Enclosure consists of five pages, exclusive of this cover page

UHoltec Center, 555 Lincoln Drive West, Marlton, NJ 08053 H O LT E C Telephone (856) 797-0900 INTERNATIONAL Fax (856) 797-0909 Holtec International Document ID 1702-6aff AFFIDAVIT PURSUANT TO 10 CFR 2.390 I, Tammy S. Morin, being duly sworn, depose and state as follows:

(1)

I have reviewed the information described in paragraph (2) which is sought to be withheld, and am authorized to apply for its withholding.

(2)

The information sought to be withheld is information provided in Attachment 1 to FirstEnergy Nuclear Operating Company (FENOC) Letter L-10-130, "Response to RAI on Unit 2 Spent Fuel Pool Re-rack Criticality Analysis". The Holtec proprietary information is in the responses to Request for Additional Information (RAI) items 18, 20, 22, 28, and 33 as marked.

(3)

In making this application for withholding of proprietary information of which it is the owner, Holtec International relies upon the exemption from disclosure set forth in the Freedom of Information Act ("FOIA"), 5 USC Sec. 552(b)(4) and the Trade Secrets Act, 18 USC Sec. 1905, and NRC regulations 10CFR Part 9.17(a)(4), 2.390(a)(4), and 2.390(b)(1) for "trade secrets and commercial or financial information obtained from a person and privileged or confidential" (Exemption 4). The material for which exemption from disclosure is here sought is all "confidential commercial information", and some portions also qualify under the narrower definition of "trade secret", within the meanings assigned to those terms for purposes of FOIA Exemption 4 in, respectively, Critical Mass Energy Project v. Nuclear Regulatory Commission, 975F2d871 (DC Cir. 1992),

and Public Citizen Health Research Group v. FDA, 704F2dl280 (DC Cir.

1983).

1 of 5

Holtec International Document ID 1702-6aff AFFIDAVIT PURSUANT TO 10 CFR 2.390 (4)

Some examples of categories of information which fit into the definition of proprietary information are:

a.

Information that discloses a process, method, or apparatus, including supporting data and analyses, where prevention of its use by Holtec's competitors without license from Holtec International constitutes a competitive economic advantage over other companies;

b.

Information which, if used by a competitor, would reduce his expenditure of resources or improve his competitive position in the design, manufacture, shipment, installation, assurance of quality, or licensing of a similar product.

c.

Information which reveals cost or price information, production, capacities, budget levels, or commercial strategies of Holtec International, its customers, or its suppliers;

d.

Information which reveals aspects of past, present, or future Holtec International customer-funded development plans and programs of potential commercial value to Holtec International;

e.

Information which discloses patentable subject matter for which it may be desirable to obtain patent protection.

The information sought to be withheld is considered to be proprietary for the reasons set forth in paragraph 4.b, above.

(5)

The information sought to be withheld is being submitted to the NRC in confidence. The information (including that compiled from many sources) is of a sort customarily held in confidence by Holtec International, and is in fact so held. The information sought to be withheld has, to the best of my knowledge and belief, consistently been held in confidence by Holtec International. No public disclosure has been made, and it is not available in public sources. All disclosures to third parties, including any required transmittals to the NRC, have 2 of 5

Holtec International Document ID 1702-6aff AFFIDAVIT PURSUANT TO 10 CFR 2.390 been made, or must be made, pursuant to regulatory provisions or proprietary agreements which provide for maintenance of the information in confidence. Its initial designation as proprietary information, and the subsequent steps taken to prevent its unauthorized disclosure, are as set forth in paragraphs (6) and (7) following.

(6)

Initial approval of proprietary treatment of a document is made by the manager of the originating component, the person most likely to be acquainted with the value and sensitivity of the information in relation to industry knowledge.

Access to such documents within Holtec International is limited on a "need to know" basis.

(7)

The procedure for approval of external release of such a document typically requires review by the staff manager, project manager, principal scientist or other equivalent authority, by the manager of the cognizant marketing function (or his designee), and by the Legal Operation, for technical content, competitive effect, and determination of the accuracy of the proprietary designation.

Disclosures outside Holtec International are limited to regulatory bodies, customers, and potential customers, and their agents, suppliers, and licensees, and others with a legitimate need for the information, and then only in accordance with appropriate regulatory provisions or proprietary agreements.

(8)

The information classified as proprietary was developed and compiled by Holtec International at a significant cost to Holtec International. This information is classified as proprietary because it contains detailed descriptions of analytical approaches and methodologies not available elsewhere. This information would provide other parties, including competitors, with information from Holtec International's technical database and the results of evaluations performed by Holtec International. A substantial effort has been expended by Holtec International to develop this information. Release of this information would improve a competitor's position because it would enable Holtec's competitor to copy our technology and offer it for sale in competition with our company, causing us financial injury.

3 of 5

Holtec International Document ID 1702-6aff AFFIDAVIT PURSUANT TO 10 CFR 2.390 (9)

Public disclosure of the information sought to be withheld is likely to cause substantial harm to Holtec International's competitive position and foreclose or reduce the availability of profit-making opportunities. The information is part of Holtec International's comprehensive spent fuel storage technology base, and its commercial value extends beyond the original development cost. The value of the technology base goes beyond the extensive physical database and analytical methodology, and includes development of the expertise to determine and apply the appropriate evaluation process.

The research, development, engineering, and analytical costs comprise a substantial investment of time and money by Holtec International.

The precise value of the expertise to devise an evaluation process and apply the correct analytical methodology is difficult to quantify, but it clearly is substantial.

Holtec International's competitive advantage will be lost if its competitors are able to use the results of the Holtec International experience to normalize or verify their own process or if they are able to claim an equivalent understanding by demonstrating that they can arrive at the same or similar conclusions.

The value of this information to Holtec International would be lost if the information were disclosed to the public. Making such information available to competitors without their having been required to undertake a similar expenditure of resources would unfairly provide competitors with a windfall, and deprive Holtec International of the opportunity to exercise its competitive advantage to seek an adequate return on its large investment in developing these very valuable analytical tools.

4 of 5

Holtec International Document ID 1702-6aff AFFIDAVIT PURSUANT TO 10 CFR 2.390 STATE OF NEW JERSEY

)

)

ss:

COUNTY OF BURLINGTON)

Ms. Tammy S. Morin, being duly sworn, deposes and says:

That she has read the foregoing affidavit and the matters stated therein are true and correct to the best of her knowledge, information, and belief.

Executed at Marlton, New Jersey, this 2 6th day of April, 2010.

Tammy S. Morin Holtec International Subscribed and sworn before me this e4 day of 2010.

NOT~j ARY C.

coI-<tcOfNf

  • S/

) e p i e ~

5 of 5 L-1 0-130 Response to RAI on Unit 2 Spent Fuel Pool Rerack Criticality Analysis Page 1 of 43 NONPROPRIETARY VERSION OF THE RESPONSE The Nuclear Regulatory Commission (NRC) staff provided a request for additional information (RAI) on the FirstEnergy Nuclear Operating Company (FENOC) license amendment request (LAR) for Unit 2 of the Beaver Valley Power Station (BVPS-2), regarding criticality analyses that support a spent fuel pool rerack. The NRC staff requests that were not previously responded to in the FENOC submittal dated March 18, 2010, are presented below in bold type, followed by the FENOC response. Triple brackets denote the start and end of proprietary information.

3. In Section 3.4, on page 3-7, the first bulleted item states, "A decrease of no more than 5% in Boron-10 (B-10), as determined by neutron attenuation, is acceptable. (This is equivalent to a requirement for no loss in boron within the accuracy of the measurement.)" This statement implies that [it] is acceptable to ignore a loss of up to 5% of the B-10 in the Metamic. It is not clear from the text provided in Section 4 that this acceptable loss of B-10 has been considered in the analysis.

Amend the analysis to consider the "acceptable" loss of B-10 or provide justification for not doing so.

Response

The 5 percent loss discussed in the RAI question represents the measurement uncertainty associated with the measurement of neutron attenuation (that is, boron-1 0 blackness) for the Metamic surveillance coupons. To account for this in the criticality analysis, the analysis will be re-performed with an additional uncertainty factor calculated by using a Metamic density that is 5 percent less than the nominal. Thus, the criticality analysis will contain two independent uncertainties associated with the boron-10 areal density in the Metamic poisons:

an uncertainty to address manufacturing tolerances in the boron-10 areal density (this was included in the original analysis), and a second uncertainty to address surveillance coupon blackness measurement uncertainty. A future supplement to the LAR will reflect the revised analysis.

14. Table 4.5.3 provides the core operating parameters used for CASMO depletion calculations. Was the analysis performed to show that these parameters are conservative and bounding? Note that consideration should be given to the full range of parameters experienced by all fuel currently stored and for fuel that will be stored in the future. Consider too that parameters that lead to spectral hardening and increased plutonium production also reduce depletion of thermal neutron L-10-130 Page 2 of 43 NONPROPRIETARY VERSION OF THE RESPONSE absorbing fission products. It should not just be assumed that anything that hardens the spectrum is conservative.

Provide the ranges of operating parameters affecting the CASMO depletion calculations and provide better justification for bounding values selected.

Response

NUREG/CR-6665, "Review and Prioritization of Technical Issues Related to Burnup Credit for LWR Fuel," provides guidance on the selection of operating parameters for spent fuel depletion calculations. The depletion calculations performed with the lattice analysis code CASMO-4 use operating parameters that harden the neutron spectrum. A harder neutron spectrum increases the production of Pu-239 and Pu-241 due to the increase in neutron capture by U-238. The harder neutron spectrum decreases the U-235 utilization due to the increase in the fission of Pu-239. These effects tend to increase the reactivity of the fuel. The following operating parameters for depletion calculations harden the neutron spectrum, with the exception of specific power and operating history, according to the guidance in NUREG/CR 6665:

Fuel temperature: A higher value increases Doppler broadening in U-238 and therefore increases production of plutonium.

The fuel temperature effect is burnup dependent and increases with burnup.

Moderator temperature: A higher value decreases moderator density slightly, reducing neutron thermalization and increasing neutron energy therefore hardening the neutron spectrum.

The moderator temperature effect increases with burnup.

Soluble boron: A higher cycle average soluble boron concentration absorbs more thermal neutrons therefore hardening the neutron spectrum.

The soluble boron effect is burnup dependent and increases with burnup.

Specific power and operating history: The effect of specific power and operating history does not have a clear trend and is dependent upon the spent fuel isotopic inventory used for burnup credit.

Based on the above conclusions from NUREG/CR 6665, the spent fuel storage rack criticality methodology calculates the spent fuel isotopic compositions with CASMO-4 using a single full power cycle, with a maximum fuel temperature (1516 degrees Fahrenheit (OF), equivalent to 150 percent of average hot full power fuel temperature), a maximum moderator temperature (638.33 OF, approximately 5 IF greater than the highest nodal end-of-cycle exposure-averaged moderator temperature seen to date at BVPS-2), maximum average soluble boron concentration (1050 parts per million (ppm), as discussed in the response to RAI 15 in the submittal dated March 18, 2010), and a typical specific power (40.4 Watts/gram (Wig), that is, thermal power divided by typical fuel mass). The maximum moderator temperature is a new value that will be used in L-10-130 Page 3 of 43 NONPROPRIETARY VERSION OF THE RESPONSE the revised criticality analysis; a future supplement to the LAR will reflect the revised analysis. The application of these parameters is conservative since they are applied to all depleted fuel used in the criticality analysis, irrespective of the axial or radial location of the fuel. As committed to in the letter dated March 18, 2010, a process will be established prior to receipt of the next reload batch of BVPS-2 fuel to ensure that the design features and operating parameters of fuel used in the future at BVPS-2 are consistent with the assumptions of the criticality analysis.

Sensitivity calculations were performed to demonstrate that the selected operating parameters were appropriate. The results show that the operating parameters are conservative and bounding. With respect to the possibility that parameters that lead to spectral hardening and increased plutonium production may also reduce depletion of thermal neutron absorbing fission products, the results of the sensitivity calculations show that if this effect is present it does not have a significant impact on the results. The results of these calculations are presented in the table below.

L-10-130 Page 4 of 43 NONPROPRIETARY VERSION OF THE RESPONSE Operating Parameter Calculations Using CASMO-4 Parameter Value Moderator T 0F 638.33 620 600 550 638.33 638.33 638.33 638.33 638.33 638.33 638.33 638.33 638.33 Fuel Temperature OF 1516 1516 1516 1516 1300 1000 1516 1516 1516 1516 1516 1516 1516 Soluble Boron ppm 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050 900 700 Power Density 40.4 40.4 40.4 40.4 40.4 40.4 38 35 30 45 50 40.4 40.4 Input File bv-opl-bv-op2-bv-op3-bv-op4-bv-op5-bv-op6-bv-op7-bv-op8-bv-op9-bv-oplO-bv-opll-bv-opl3-bv-opl4-wt%U-

{enr}

{enr}

{enr}

{enr}

{enr}

{enr}

{enr}

{enr}

{enr}

{enr}

{enr}

{enr}

{enr}

235 GWD/MTU kinf Delta Delta Delta Delta Delta Delta Delta Delta Delta Delta Delta Delta kinf 2

10 0.8926

-0.0033

-0.0059

-0.0101

-0.0013

-0.0033 0.0002 0.0005 0.0009

-0.0004

-0.0008

-0.0013

-0.0032 2

20 0.8312 -0.0071

-0.0127

-0.0222

-0.0028

-0.0071 0.0002 0.0004 0.0007

-0.0003

-0.0007

-0.0026

-0.0062 2

30 0.7836

-0.0104

-0.0188

-0.0329

-0.0041

-0.0101 0.0001 0.0002 0.0003

-0.0002

-0.0005

-0.0036

-0.0086 2

40 0.7489

-0.0129

-0.0232

-0.0402

-0.0048

-0.0121 0.0001 0.0001 0.0000

-0.0001

-0.0003

-0.0042

-0.0100 2

50 0.7254

-0.0143

-0.0258

-0.0442

-0.0052

-0.0130 0.0000 0.0000

-0.0001

-0.0001

-0.0002

-0.0045

-0.0108 2

60 0.7103

-0.0152

-0.0271

-0.0461

-0.0053

-0.0133 0.0000 0.0000

-0.0001 0.0000

-0.0002

-0.0046

-0.0109 3

10 0.9940

-0.0017

-0.0031

-0.0052

-0.0007

-0.0018 0.0002 0.0004 0.0008

-0.0003

-0.0007

-0.0006

-0.0013 3

20 0.9242

-0.0045

-0.0082

-0.0143

-0.0018

-0.0046 0.0002 0.0004 0.0009

-0.0004

-0.0008

-0.0014

-0.0032 3

30 0.8641

-0.0077

-0.0141

-0.0250

-0.0031

-0.0076 0.0001 0.0003 0.0006

-0.0003

-0.0006

-0.0022

-0.0053 3

40 0.8135

-0.0110

-0.0200

-0.0356

-0.0041

-0.0104 0.0001 0.0001 0.0002

-0.0002

-0.0004

-0.0031

-0.0072 3

50 0.7731

-0.0136

-0.0248

-0.0439

-0.0050

-0.0124 0.0000 0.0000

-0.0001

-0.0001

-0.0002

-0.0037

-0.0088 3

60 0.7430 -0.0154

-0.0279

-0.0489

-0.0054

-0.0136 0.0000

-0.0001

-0.0003 0.0000

-0.0001

-0.0041

-0.0098 4

10 1.0654

-0.0008

-0.0014

-0.0024

-0.0004

-0.0010 0.0002 0.0004 0.0007

-0.0003

-0.0006

-0.0002

-0.0006 4

20 0.9967

-0.0027

-0.0049

-0.0085

-0.0012

-0.0029 0.0002 0.0005 0.0010

-0.0004

-0.0008

-0.0007

-0.0017 4

30 0.9358

-0.0052

-0.0094

-0.0168

-0.0021

-0.0053 0.0002 0.0004 0.0008

-0.0004

-0.0007

-0.0013

-0.0030 4

40 0.8804 -0.0081

-0.0149

-0.0267

-0.0032

-0.0079 0.0001 0.0003 0.0004

-0.0003

-0.0006

-0.0020

-0.0046 4

50 0.8314

-0.0112

-0.0205

-0.0368

-0.0042

-0.0104 0.0001 0.0001 0.0000

-0.0001

-0.0003

-0.0026

-0.0062 4

60 0.7900

-0.0139

-0.0254

-0.0456

-0.0050

-0.0124 0.0000 0.0000

-0.0002 0.0000

-0.0002

-0.0032

-0.0077 5

10 1.1178

-0.0003

-0.0005

-0.0007

-0.0002

-0.0006 0.0001 0.0003 0.0007

-0.0003

-0.0005

-0.0001

-0.0002 5

20 1.0524 -0.0015

-0.0028

-0.0047

-0.0008

-0.0019 0.0002 0.0005 0.0010

-0.0004

-0.0008

-0.0004

-0.0009 5

30 0.9939

-0.0033

-0.0060

-0.0106

-0.0014

-0.0036 0.0002 0.0005 0.0010

-0.0004

-0.0008

-0.0007

-0.0017 5

40 0.9393

-0.0056

-0.0103

-0.0184

-0.0023

-0.0057 0.0002 0.0004 0.0007

-0.0003

-0.0007

-0.0012

-0.0028 5

50 0.8883

-0.0083

-0.0153

-0.0276

-0.0032

-0.0080 0.0001 0.0002 0.0003

-0.0002

-0.0005

-0.0017

-0.0041 5

60 0.8418

-0.0112

-0.0206

-0.0374

-0.0041

-0.0103 0.0000 0.0000

-0.0001

-0.0001

-0.0003

-0.0023

-0.0055 Table Note: 'Weight percent' is shown as'wt%' and fuel burnup using'gigawatt day per metric ton uranium' is shown as'GWD/MTU' in this submittal L-10-130 Page 5 of 43 NONPROPRIETARY VERSION OF THE RESPONSE

18. Section 4.2.1, first paragraph - the last sentence states: "This approach has been validated in [4.3] by showing that the cross sections result in the same reactivity in both CASMO-4 and MCNP4a."

This is not "validation". This cross-code comparison utilizing the same cross sections does not tell us anything about the potential composition and cross-section errors and associated biases introduced by the modeling of lumped fission products and use of lumped fission product cross sections.

What is the worth of the lumped fission products in the fuel storage racks? What fission products are included in the lumped fission products?

The "5% of the reactivity decrement" suggested by the Kopp memo does not cover modeling simplifications and approximations such as use of lumped fission products.

Eliminate or provide better justification for the use of lumped fission products. Justification for the use of the "lumped fission product" modeling simplification should include quantification of associated bias and bias uncertainty.

Response

The "validation" discussed in Section 4.2.1 of the Holtec Licensing Report regarding the transfer of nuclide number densities and lumped fission product (LFP) cross sections from CASMO-4 to the Monte Carlo N-Particle (MCNP) code MCNP4a was not intended to be a validation of the depletion capabilities of CASMO-4. Rather, it was intended to show that the data transfer itself was successful and that both codes, when using the same nuclide number densities and lumped fission product cross sections, produced very similar results.

The worth of the LFP is about 1 percent delta keff.

The lumped fission products used in CASMO-4 represent a limited population of fission products that are either slowly saturating fission products with burnup or never saturate. The slowly saturating lumped fission product's (SSFP) detailed isotopic characterization and the non-saturating lumped fission product's (NSFP) detailed isotopic characterization is presented in the two tables below (data taken from the chart of the nuclides and "Atlas of Neutron Resonances," S.F. Mughabghab, 5th Ed.).

L-10-130 Page 6 of 43 NONPROPRIETARY VERSION OF THE RESPONSE

-If L-10-130 Page 7 of 43 NONPROPRIETARY VERSION OF THE RESPONSE

))]

The use of the CASMO-4 LFP cross sections in MCNP may introduce an additional uncertainty to the final MCNP calculated reactivity. To account for this additional uncertainty, an analysis of cross section uncertainty data was performed to develop a cross section uncertainty factor that can be applied to the analysis. The LFP uncertainty factor will be applied to the final MCNP calculated reactivity by multiplying the uncertainty factor (that is, percent) by the reactivity decrement calculated from the reactivity difference between the MCNP calculation with LFPs and the MCNP calculation without LFPs.

The information presented in the above tables contains cross section data (including uncertainties) for total, scattering, and/or capture thermal cross sections, resonance cross sections, and U-235 fission product yields for each isotope. The determination L-1 0-130 Page 8 of 43 NONPROPRIETARY VERSION OF THE RESPONSE of the LFP uncertainty factor is performed in two different ways and summarized in the table below:

(([PROPRIETARY -

Summary of LFP Factor Calculation Method 1 Method 2 Cross Section Cross Section Cross Section Description (b)

Uncertainty (b)

Cross Section (b)

Uncertainty (b)

SSFP 5576.35 221.56 38.33 2.11 NSFP 834.99 75.29 12.79 1.06 Total 6411.33 296.85 51.11 3.17 Factor 4.63%

6.21%

95/95 9.26%

12.41%

For both methods the final result is determined at a 95/95 confidence interval. For both methods, the final result is between 9-13 percent. For additional conservatism, the final LFP factor is determined to be 15 percent. A future supplement to the LAR will reflect the revised analysis.

20. The text in Section 4.7.4, "Isotopic Compositions," describes modeling approximations related to calculation and use of burned fuel compositions. Provide additional detail in this section to clearly state the conditions used in the calculation of fuel compositions as a function of initial-enrichment and fuel burnup.

From the text in Section 4.7.4, it appears that assembly average compositions are used rather than pin-by-pin compositions. This minimizes the impact on reactivity of removing WABA rods from an assembly. During depletion, the WABA rods depress power/burnup locally until the WABA rods are removed. Provide additional detail describing and justifying the use of modeling approximations associated L-1 0-130 Page 9 of 43 NONPROPRIETARY VERSION OF THE RESPONSE with modeling burned fuel. Where appropriate, include biases and bias uncertainties associated with the modeling simplifications and approximations.

Response

To perform the criticality evaluation for spent fuel in MCNP4a, the isotopic composition of the fuel is calculated with the depletion code CASMO-4 and then specified as input data into MCNP4a. The depletion calculations are performed using bounding operating parameters as shown in RAI 14. The depletion calculations do not include any integral or non-integral reactivity control devices. The effect of integral or non-integral reactivity control devices is applied as a reactivity bias, which is discussed in RAI item 24. The CASMO-4 calculations to obtain the isotopic compositions for MCNP4a are performed for fuel with an initial enrichment of 2.0 weight percent U-235 to 5.0 weight percent U-235 in increments of 0.5 weight percent U-235. For each enrichment step, the depletion calculations determine the isotopic concentration in burnup steps of 2.5 GWD/MTU or less. The isotopic composition for any given burnup is then determined by linear interpolation. A complete list of the isotopes considered in the spent fuel composition is provided in the table below. The isotopic concentrations are determined at zero hour cooling time, without xenon, and the amount of Np-239 present is added as additional Pu-239 (as described in the response to RAI 25 in the submittal dated March 18, 2010). A future supplement to the LAR will reflect the revised text.

L-10-130 Page 10 of 43 NONPROPRIETARY VERSION OF THE RESPONSE

)PRIITARY -

I))

L-10-130 Page 11 of 43 NONPROPRIETARY VERSION OF THE RESPONSE With respect to the use of assembly average compositions, their use is appropriate because wet annular burnable absorber (WABA) rods are not included during depletion calculations that determine the isotopes used in the MCNP calculations.

Rather, a reactivity bias is determined to account for the potential reactivity effect of the WABA rods, as described in the response to RAI 21 in the submittal dated March 18, 2010, and in RAI 24.

22. As described in Section 4.7 and in other places in the report, CASMO-4 was used to provide rack keff sensitivity information. Considering that the storage rack is constructed of "fabricated" cells and "developed" cells (see Fig. 2.6.2), it is not obvious what the CASMO model looked like. Did CASMO model simplifications affect the results?

Describe the CASMO model used for fuel storage rack models. Where appropriate, include biases and uncertainties associated with CASMO model simplifications.

Response

As described in Figure 2.6.2 in the Holtec Licensing Report, the storage racks are constructed using developed cells and fabricated cells. Fabricated cells are storage rack cells that have four cell walls with neutron absorber held in place by sheathing on each exterior face of each cell wall. When a storage rack is built, four fabricated cells are connected (([PROPRIETARY -

=))]. The location in the center of the four fabricated cells is the developed cell.

This level of detail is not possible with the CASMO-4 code model. Rather, the CASMO-4 model uses a simplified geometry. The simplified model does not consider that the racks contain both developed cells and fabricated cells. Rather, the model evenly distributes the thickness of the storage cell wall and sheathing around the neutron absorber. The CASMO-4 model is a reflective model and therefore the reflective boundary is the centerline of the poison. See the figure below for a 2D representation of the CASMO-4 model.

L-10-130 Page 12 of 43 NONPROPRIETARY VERSION OF THE RESPONSE Ce 1 Wall Fuel Rod Moderaltor Poison L-10-130 Page 13 of 43 NONPROPRIETARY VERSION OF THE RESPONSE In order to show that the simplified CASMO-4 storage rack model is acceptable to use for tolerance c calculations were performed using both CASMO-4 and MCNP4a for three tolerances: (([PROPRIETARY -

fl]. The MCNP4a model does not contain the geometry simplifications inherent in the CASMO-4 model. The results of these calculations are shown in the table below and show that both codes calculate the same result within the uncertainty of the MCNP4a code results. Therefore, the use of the CASMO-4 code with a simplified storage rack model is acceptable to use for tolerance calculations. (([PROPRIETARY -

L-10-130 Page 14 of 43 NONPROPRIETARY VERSION OF THE RESPONSE The following information explains why use of a simplified MCNP4a model was also appropriate considering the same issue related to fabricated and developed cells.

The MCNP model does not consider that the racks contain both developed cells and fabricated cells. Rather, the MCNP model is a simplified model (([PROPRIETARY -

))]. The simplified MCNP4a model is shown in the first figure below.

A MCNP4a model with more detailed geometry was developed and is shown in the second figure below.

I))

L-1 0-130 Page 15 of 43 NONPROPRIETARY VERSION OF THE RESPONSE Sensitivity studies were performed to demonstrate that the reactivity effect of the MCNP model simplifications is within the uncertaint of the calculations.

))] The results are presented in the table below and the small delta kcaic values show that the model simplifications are acceptable.

(([PROPRIETARY -

24. Section 4.7.2 addressed the reactivity effect of fuel assembly reactivity control devices. There are three issues associated with the analysis described in this section:
a. It does not appear that depletion with control rods present was considered. Frequently, second-and third-cycle fuel is placed under control rods, some of which may be used to control reactor power.

Thus a realistic fuel depletion scenario could include first cycle depletion with burnable absorbers and second cycle of depletion with partially inserted control rods. Some plants have also included part-length absorbers rods in some peripheral locations to reduce neutron flux to reactor vessel welds. [In] low-leakage loading patterns, these peripheral locations frequently hold fuel that is being used for a third cycle.

Provide justification for modeling reactivity control devices throughout fuel assembly life.

Response: In the letter dated March 18, 2010, sub-item 24.a. was responded to, with the exception of the "part-length absorber rods" discussion. The following new information about part-length absorber rods is provided:

To address the potential impact of part-length absorber rods, sensitivity calculations were performed to determine the reactivity effect of part length integral fuel burnable absorbers (IFBA) and part length WABA rods. The results of the sensitivity studies show that the reactivity effect of cases using full length IFBA and full length WABA rods bound the cases that use part length IFBA and part length WABA rods. A complete description is provided in the response to RAI item 33. With respect to depletion with control rods, the only cycle that used control rods during depletion was Operating Cycle 1. During Cycle 1, control rods were minimally inserted for a short time. The potential reactivity effect due to the L-10-130 Page 16 of 43 NONPROPRIETARY VERSION OF THE RESPONSE operation with control rods inserted is offset by the reactivity bias for burnable absorbers applied to all fuel in the analysis. The fuel assemblies that contained the control rods that were inserted during Cycle 1 have never contained burnable absorbers. Since the reactivity bias for burnable absorbers is applied to all fuel, even fuel that physically never contained burnable absorbers, the analysis bounds the case of partial control rod insertion in Cycle 1.

b. It appears that IFBA and WABA were not modeled during depletion as being present in the same assembly. Does some mechanical feature or technical specification prevent them from being in the same assembly?

Provide justification for not modeling both in the same assembly.

Response: Sub-item 24.b was addressed in the letter dated March 18, 2010.

c. Some plants have used standard Pyrex glass burnable absorbers.

These absorbers deplete more slowly and can result in increased plutonium generation. Confirm that standard Pyrex glass burnable absorbers have not been used at BVPS-2. If they have been used, revise the analysis to address such use.

Response: Sub-item 24.c was addressed in the letter dated March 18, 2010.

26. Section 4.7.5 addresses uncertainty in depletion calculations. There is no basis in the Kopp memo to suggest that coverage of changes in fuel geometry during irradiation was intended. Uncertainty in keff due to random fuel geometry changes should be handled as variations in the parametric ranges of the analysis and included along with the other uncertainties. Variation in keff due to anticipated geometry changes during irradiation should be handled as a bias.

Confirm that the impacts of fuel geometry changes during irradiation are properly handled.

Response

During irradiation in light water reactors the fuel assemblies undergo physical changes associated with irradiation and residence time in an operating reactor.

Some of those changes are: fuel pellet densification, crud build up on the outside surface of the fuel rod, and changes to clad geometry due to collapse of the pellet/cladding gas gap in the fuel rod (i.e., clad creep-down) and fuel rod growth.

These fuel geometry changes are accounted for in the following way:

Pellet densification: The spent fuel rack criticality methodology already includes an increase in fuel pellet density that covers both fresh and spent fuel. Therefore no additional calculations are required.

Crud buildup: Crud buildup on the cladding increases the fuel-to-moderator ratio and therefore reduces reactivity. Thus, no additional calculations are required. Also, there has been no measureable crud-induced power shift L-10-130 Page 17 of 43 NONPROPRIETARY VERSION OF THE RESPONSE (CIPS) at BVPS-2 since original startup of the plant, which indicates that crud deposition on the fuel has not been significant.

Clad geometry: Both fuel rod growth and clad creep-down have the potential to decrease the fuel-to-moderator ratio, thus potentially increasing reactivity.

To address clad creep-down, the clad inner diameter (ID) was reduced such that the pellet-clad gap was 0.0001 inch, while simultaneously reducing the clad outer diameter (OD) to preserve overall clad volume. Then, to address clad thinning due to fuel rod growth, the clad OD was further reduced to allow for the maximum possible fuel rod growth. Calculations were performed to determine the reactivity impact of this "creep" model on the magnitude of the fuel tolerance uncertainties. The results are shown in the following six tables.

The maximum delta-k value of 0.0075 is essentially equivalent to the results of the fuel tolerance uncertainty calculations without the creep model (maximum delta-k of 0.0074) that was provided in Table 4.7.13 in the original Holtec Licensing Report. A future LAR supplement will reflect the revised analysis.

Reion 2 CASMO Calculations for Fuel Tolerane Uncertainties With Creep Rod Rod Clad Clad Clad Clad Fuel Fuel Fuel Description Ref Case Pitch -

Pitch -

OD +

OD -

ID+

ID -

Pellet Pellet Pellet Ent OD+

OD -

+

Stat B__mp Input File Combo ppm GWD/ EMn bv-cfw-b--cfla-v,-cftb-bv-cftc-v,-cftd-brv-cfte-bv-cfff-bv-cftg-bv-cfth-bv-,cfl i-20 MTU 20-0 20-0 20-0 20-0 20-0 20-0 20-0 20-0 20-0 0

0 0.0 2

0.9691 0.0006 -0.0077 -0.0012 0.0012 0.0011 -0.0011 0.0001

-0.0001 0.0073 0.0075 0

0.1 2

0.9660 0.0006 -0.0076 -0.0012 0.0012 0.0011 -0.0011 0.0001

-0.0001 0.0073 00075 0

2.0 2

0.9517 0.0006 -0.0078 -0.0011

.0011 0.0010 -0.0010 0.00021 -0,0002 0.0063 0.0070 0

4.0 2

0.9362 0.0006 -0.0079 -0.0011 0.0010 0.0009 -0.0009 0.0002

-0.0002 0.0066 0.0068 0

6.0 2

0.9198 0.0006 -0.0079 -0.0010 0.0009 0.0008 -0.0008 0.0002

-0.0002 0.0064 0.0066 0

&0 2

0.903S 0.0006 -0.0078 -0.0009 0.0009 0.0008 -0.0008 0.0003

-0.0003 0-0063 0.0064 0

10-0 2

0.8886 0.0006 -0.0078 -0.0008 0.0009 0.0007 -0.0007 0-0003

-0.0003 0.0061 0.0062 0

11.0 2

0-8913 0.0006 -0.0077 -0.0007 0.0007 0,0006 -0.0006 0.0004

-0.0004 0.0060 0.0061 0

12.5 2

0.8707 0.0006 -0.0077 -0.0007 0.0006 0.0006 -0.0006 0,0004 0004 0.0059 0.0060 0

15.0 2

0.8538 0.0005 -00076 -0.0005 0.0005 0.0005 -0.0005 0.0005

-0.0005 0.0057 0.0058 0

0._5 2

0.8377 0.0005 -0.0074 -0.0004 0.0004 0.0004 -0.0004 0.0006

-0.0006 0.0055 0.0056 0

20.0 2

0. 8S5 0.0005 -0.0073 -0.0003 0.0003 0.0003 -0.0003 0.0006

-0.0006 0.0052 0.0053 0

22.5 2

0.8082 0.0005 -0.0072 -0.0002 0.0002 0.0002 -0.0002 0.0007

-0.0007 0.0050 0.0051 0

25.0 2

0.7948 0.0005 -0.0071 -0.0001 0.0001 0.0001 -0.0001 0.0003

-0.000S 0.0047 0.0048 0

27.5 2

0.7823 0.0005 -0.0070 0.0000 0.0000 0.0000 0.0000 0.0009

-0.0009 0.0044 0.0045 0

30.0 2

0.7707 0.0005 -0.0070 0.0001 -0.0001 -0.0001 0.0001 0.0009

-0.0009 0.0041 0.0043 0

32.5 2

0.7599 0.0005 -0.0069 0.0002 -0.0002 -0.0002 0.0002 0.0010

-0.0010 0.0038 0.0040 0

35.0 2

0.7501 0.0005 -0.0069 0.0003 -0.0003 -0.0002 0.0002 0.0010

-0.0010 0.0035 0.0037 0

37.5 2

0.7411 0.0004 -0.0069 0.0003 -0.0003 -0.0003 0.0003 0.0011

-0.0011 0.0032 0.0035 0

42.5 2

0.7255 0.0005 -0.0068 0.0005 -0.0004 -0.0004 0.0004 0.0011

-0.0012 0.0027 0.0030 0

45.0 2

0.7189 0.0004 -0.0068 0.0005 -0.0005 -0.0004 0.0004 0-0012

-0.0012 0.0024 0.0028 0

47._5 2

0.7129 0.0004 -0.0069 0.0005 -0.0005 -0.0005 0.0005 0.0012

-0.0012 0.0021 0.0026 0

50.0 2

0.7075 0.0005 -0.0069 0.0006 -0.0006 -0.0005 0.0005 0.0012

-0.0012 0.0019 0.0024 0

52.5 2

0.7028 0.0004 -0.0069 0.0006 -0.0006 -0.0005 0.0005 0.M12

-0.0012 0.0017 0.0023 0

55.0 2

0.6985 0.0005 -0.0069 0.0006 -0.0006 -0.0005 0.0006 0.0013

-0.0013 0.0015 0.0022 0

57.5 2

0.6948 0.0005 -0.0070 0.0006 -0.0006 -0.0006 0.0006 0.0013

-0.0013 0.0013 0.0021 0

60.0 2

0.6915 0.0005 -0.0070 0.0007 -0.0007 -0.0006 0.0006 0.0013

-0.0013 0.0011 0.0020 Table Note: Enrichment is shown as 'Enr' in this submittal L-10-130 Page 18 of 43 NONPROPRIETARY VERSION OF THE RESPONSE Region2 CASMO Calculations forFuel Tolerance Uncertainties With Creep 1

1 1Fuel Fuel Fuel Rod Rod Clad Clad Clad Clad Description Ref Care Pitch Pitch-OD+

OD-I]+

ID-Pellet Pellet PelletEnt OD +

OD-

+

Stat.

Bu__p Inp__ File Combo ppm GWD!D Eur bv-cftn-bv-cfta-bv-cftb-bv-cftc-by-cftd-bv-cfte-bv-cflf-bv-cftg-bv-cfth-bv-cfti-33

__MTU 35-0 35-0 35-0 35-0 35-0 35-0 35-0 35-0 35-0 0

0 0.0 3.5 1.1205 0-0009 -0.0121 -0.0014 0.0014 0012 -0.0012 0.0000 0.0001 0M0034 0.0040 0

0.1 3.5 1.1182 0.0009 -0.0120 -0.0014 0.0013 0.0012 -0.0012 -0.0001 0.0000 0.0034 0.0040 0

2.0 3.5 1.0979 0M0009 -0.0120 -0.0013 0,0013 0.0012 -0.0012 -0.0001 0.0000 0.0034 0.0039 0

4.0 315 1.0811 0.0009 -0.0119 -0.0013 0.0013 0.0011

-0.0011 -0.0001 0.0000 0.0034 0.0040 0

6.0 3.5 1.0640 0.0008 -0.011S -0.0013 0.0013 0.0011

-0.0011 0.0000 0.0000 0.0035 0.0040 0

8.0 3.5 1.0473 0.0008 -0.0118 -0.0012 0.0012 0.0011 -0.0011 0.0000 0.0000 0.0035 0.0040 0

10.0 3,5 1.0312 0.0008 -0.0116 -0.0012 0.0012 0.0010 -0.0011 0,0000 0.0000 0.0036 0.0040 0

11.0 3.5 1.0234 0.0008 -0.0116 -0.0012 0.0012 0.0010 -0.0010 0.0000 0.0000 0.0036 0.0040 0

12.5 3.5 1.0120 0.000

-0.0115 -0.0011 0.0011 0.0010 -0.0010 0.0000 0.0000 0.0036 0.0040 0

15.0 3.5 0.9937 0.t000

-0.0113 -0.0011 0.0011 0.0009 -0.0009 0.0001

-0.0001 0.0036 0.0040 0

17.5 3.5 0.9759 0.0008 -0.0111 -0.0010 0.0010 0.0009 -0.0009 0.0001

-0.0001 0.0037 0.0040 0

20.0 3.5 0.9586 0.0007 -0.0109 -0.0009 0.0009 0.0008 -0.0008 0.0001

-0.0002 0.0037 0.0039 0

22.5 3.5 0.9417 0.0007 -0.0107 -0.0008 0.0008 0.0007 -0.0007 OD002

-0.0002 0.0037 0.0039 0

25.0 3.5 0.9253 0.0007 -0.0105 -0.0007 0.0007 0.0006 -0.0006 0.0003

-0.0003 0.0037 0.0039 0

27.5 3.5 0.9093 0.0007 -0.0102 -0.0006 0.0006 0.0005 -0.0006 0.0003

-0.0004 0.0037 0.0039 0

30.0 3.5 0.8937 0..0007 -0.0100 -0.0005 0.0005 0.0005 -0.0005 0.0004

-0.0004 0.0037 0.0039 0

32.5 3,5 0.m785 0.0007 -0.0098 -0.0005 0.0004 0.0004 -0.0004 0.0005

-0.0005 0.0037 0.0038 0

35.0 3.5 0.S638 0.0006 -0.0096 -0.0004 0.0003 0.0003 -0.0003 0.0005

-0.0006 0,0037 0.0038 0

37.5 3.5 0.8495 0.0006 -0.0093 -0.0002 0.0002 0.0002 -0.0002 0.0006

-0.0006 0.0036 0.0037 0

42.5 3.5 0.3225 0.0006 -0.0090 -0.0001 0.0000 0.0000 0.0000 0.0008

-0.0008 0.0035 0.0036 0

45.0 3.5 0.8099 0.0006 -0,0088 0.0000 0.0000 0.0000 0.0000 0.0008

-0.0008 0.0033 0.0035 0

47.5 3.5 0.7978 0.0006 -0.0086 0.0001 -0.0001 -0.0001 0.0001 0.0009

-0.0009 0.0032 0.0034 0

50.0 3.5 0.7863 0.0005 -0.0084 0.0002 -0.0002 -0.0002 0.0002 0.0010

-0.0010 0.0031 0.0033 0

52.5 3.5 0.7755 0.0005 -0.0083 0.0003 -0.0003 -0.0003 0.0003 0.0010

-0.0010 0.0030 0.0032 0

55.0 3.5 0.7653 0..0005 -0.0082 0.0004 -0.0004 -0.0003 0.0003 0.0011

-0.0011 0.0028 0.0031 0

57.5 3.5 0.7558 0.0005 -0.0081 0.0004 -0004-0.0004 t0004 00 0.0011

-00011 0.0027 0.0030 0

60.0 3.5 0.7469 0.0005 -0.0080 0.0005 -0.0005 -0.0004 0.0004 0,0012

-0.0012 0.0025 0.0029 L-10-130 Page 19 of 43 NONPROPRIETARY VERSION OF THE RESPONSE Region 2 CASMIO Calculatios for Fuel Tolerance Uncertainties With Creep jJ Fuel IFuel Fuel Rod Rod Clad Clad Clad Clad F

Description Ref Care Pitch÷ Pitch -

OD +

OD -

ID+

ID -

Pellet Pellet Pellet Eni OD-OD -

Stat.

ppm,.Dp E cput File Combo ppm GWD/ Er bv-cft-bv-cfta-bt.-cftb-bv-cItc-bv-cftd-bv-cfte-bv-cftf-bv-cftg-bv-cfth-bv-cti-50 MTU 50-0 50-0 50.0 50-0 50-0 50-0 50-0 50-0 50-0 0

0 0.0 5

1.2003 0-0010 -00146 -0.0014 0.0014 0.0013 -0.0012 -0.0001 0.0002 0.0021 0.0030 0

0.1 5

1.1M95 0-0010 -0.0146 -0.0014 0.0014 0.0012 -0.0012 -0.0002 0.0002 0.0021 0.0030 0

2.0 5

1.177.5 0.0010 0145 -0.0014 0.0014 0.0012 -0.0012 -0.0002 0.0002 0.0021 0.0030 0

4.0 5

1.162)4 0.0010 -0.0144 -0.0014 0.0014 0.0012 -0.0012 -0.0002 0.0002 0.0021 0.0030 0

6.0 5

1.1471 0.0010 -0.0143 -0.0014 0.0014 0.0012 -0.0012 -0.0002 0.0002 0.0022 0.0030 0

8.0 5

1.1320 0.0010 -0.0142 -0.0014 0.0014 0.0012 -0.0012 -0.0002 0.0002 0002 0.0030 0

10.0 5

1.1173 0.0010 -0.0141 -0.0014 0.0014 0.0012 -0..0012 -0.0002 0.0002 0.0023 0.0031 0

11.0 5

1.1102 0.0010 -0.0140 -0.0014 0.0013 0.0012 -0.0012 -0.0002 0.0002 0.0023 0.0031 0

12.5 5

1.0997 0.0010 -0.0139 -0.0013 0.0013 0.0012 -0.0012 -0.0002 0.0002 0.0023 0.0031 0

15.0 5

1.0828 0.0009 -0.0138 -0.0013 0.0013 0.0011 -0.0011 -0.0001 0.0002 0.0024 0.0031 0

17.5 5

1.0664 0.0009 -0.0136 -0.0013 0.0012 0.0011 -0.0011 -0.0001 0.0001 0.0024 0.0031 0

20.0 5

1.0504 0.0009 -0.0135 -0.0012 0.0012 0.0011 -0.0011 -0.0001 0.0001 0.0025 0.0031 0

22.5 5

1.0348 0.0009 -0.0133 -0.0012 0.0011 0.0010 -0.0010 -0.0001 0.0001 0.0025 0.0031 0

25.0 5

1.0196 0.0009 -0.0131 -0.0011 0.0011 0.0010 -0.0010 -0.0001 0.0000 0.0026 0.0031 0

27.5 5

1.0046 0.0009 -0.0129 -0.0011 0.0010 0.0009 -0.0009 0.000 0.0000 0.0026 0.0031 0

30.0 5

0.9898 0.0008 0127 -0.0010 0.0010 0.0009 -0.0009 0.0000 0.0000 0.0027 0.0031 0

32.5 5

0.9751 0.000

-0.0125 -0.0009 0.0009 0.0003 -0.0008 0.0001

-0.0001 0.0027 0.0031 0

35.0 5

0.9607 0.0008 -0.0123 -0.0009 0.0008 O.0008 -0.0008 0.0001

-0.0001 0.0028 0.0031 0

37.5 5

0.9464 0.000S -0.0121 -0.0008 0.0008 0.0007 -0.0007 0.0002

-0.0002 0.0028 0.0031 0

42.5 5

0.9184 0.0008 -0.0116 -0.0006 0.0006 0.0006 -0.0005 0.0003

-0.0003 0.0028 0.0031 0

45.0 5

0.9047 0.0007 -00114 -0.0005 0.0005 0.0005 -0.0005 0.0003

-0.0003 0.0029 0.0030 0

47.5 5

0.8912 0.0007 -0.0111 -0.0005 0.0005 0.0004 -0.0004 0.0004

-0.0004 0.0029 0.0030 0

50.0 5

0.8779 0.0007 -0.0109 -0.0004 0.0004 0.0003 -0.0003 0.0005

-0.0005 0.0028 0.0030 0

52.5 5

0.8650 0.0007 -0.0107 -0.0003 0.0003 0.0003 -0.0002 0.0005

-0.0005 0.0029 0.0030 0

55.0 5

0.8523 0.0007 -0.0105 -0.0002 0.0002 0.0002 -0.0002 0.0006

-0.0006 0.0028 0.0030 0

57.5 5

0.8400 0..0006-0.0102 -0.0001 00001 0I0001 -0.0001 0.007

-0.0007 0.0028 0.0029 0

60.0 5

0.8280 0-0006 -00100 00000 0.000000000 00000 0.0007

-0.0008 0.0027 0.0029 L-10-130 Page 20 of 43 NONPROPRIETARY VERSION OF THE RESPONSE Reeion 2 CASMO Calculatiom for Fuel Tolerance Uncertainties With Creep Fuel Fuel Fuel Rod Rod Clad Clad Clad Clad Description RefCase Pit-ch' Pitch-OD+

OD-

]ID+

ID-Pellet Pellet PelletEw OD+

OD-

+

Stat.

_u____p Enput File bv-cfta-bv-ctkc-bv--cfte-Cmb ppm GWDi Enr bv-cftn-b0-

,v-cfib-I0-by-cftd-20-bv-cftf-bv-cftg-bv-cfth-bv-cfli-2 MTU 20-0 200 20-2000 20-20-2000 20-

,0 2000 20-2000 20-2000 2000 2.000 077 2000 2000

-1 2000 0.0 2

0.9691 0,0006 0077 -0.0012 0.0012 0.01 1 -0.0011 U.001

-0.0001

0. 00 73 0.0075 2000 0.1 2

0.9660 0.0006 -0.0076 -0.0012 0.0012 0.0011 -0.0011. 00001

-0.0001 0.0073 0.0075 200 2.0 2

0.9517 0.0006 -0.0078 -0.0011 0.0011 0.0010 -0.0010 0.0002

-0.0002 0.0068 0.0070 2000 4.0 2

0.9362 0.0006 -0.0079 -0.0011 0.0010 0.0009 -0.0009 0.0002

-0.0002 0.0066 0.0063 2000 6.0 2

0.9198 0.0006 -0.0079 -0.0010 0.0009 0.0008 -0.0008 0.0002

-0.0002 0.0064 0.0066 2000 8.0 2

0.9O38 0.0006 -0.007i -0.0009 0.0009 o.ooo0 0o0OS 0.0003

-0A003 0.0063 0.0064 2000 10.0 2

0.8886 0.0006 -0.0078-40008 0.0008 0.0007 -0.0007 0.0003

-0003 0.0061 0.0062 2000 11.0 2

0.8813 0.0006 -0.0077 -0.0007 0.0007 00006 -0.0006 0.0004

-0. 0004 0.0060 0.0061 2000 12.5 2

0.8707 0.0006 -0.0077 -O.007 0.0006 0.0006 -0.0006 0.0004

-0.0004 0.005-0.0060 2000 15.0 2

0.8538 0.0005 -0.0076 0005 0.005 0.0005 -0.0005 0.0005

-0.0005 0.0057 0.0058 2000 17.5 2

0.8377 0.0005 -0.0074 -0.0004 0.0004 0.0004 -0.0004 0.0006

-0.0006 0.0055 0.0056 2000 20.0 2

0.8225 0.0005 -0.0073 -0.0003 0.0003 0.0003 -0.0003 0.0006

-0.0006 0.0052 0.0053 2000 22.5 2

0.8082 0.0005 0072 -0.0002 0 0002 0.0002 -0.0002 0.0007

-0.0007 0.0050 0.0051 2000 25.0 2

0.7948 0.0005 -0.0071 0001 0.0001 0,0001 0001 0-0008 0008 0.0047 0.0048 2000 27.5 2

0.7823 0.0005 -0.0070 0.0000 0-0000 0.00 0.0000 0.000 4-0009 0.0044 0.0045 2000 30.0 2

0.7707 0.0005 0070 0.0001 -0.0001 -0.0001 0.0001 0.0009

-0.0009 0.0041 0.0043 2000 32.5 2

0.7599 0.0005 -0.0069 0.0002 -0.0002 -0.0002 0.0002 0.0010

-0.0010 0.0038 0.0040 2000 35.0 2

0.7501 0.0005 -0.0069 0.0003 -0.0003 -0..0002 0.0002 0.0010

-0.0010 0.00,35 0.0037 2000 37.5

-2 0.7411 0.0004 -0.0069 0.0003 -0.0003 -0.0003 0.0003 0.0011

-0.0011 0.0032 0.0035 2000 42.5 2

0.7255 0.0005 -0.0068 0.0005 -0.0004 -0.0004 0.0004 0.0011

-0.0012 0.0027 0.0030 2000 45.0 2

07189 0,0004 -00068 0.0005 -0.0005 -0.0004 00004 00012

-0 0012 0.0024 0.0028 2000 47.5 2

0.7129 0.0004 0069 0.0005 00005-0.0005 0-0005 0.0012 0012 0.0021 0.0026 2000 50.0 2

0M7075 0.0005 -0.0069 0.0006 -0.0006 -0.0005 0-0005 00012

-0.0012 0.0019 0.0024 2000 52.5 2

0.7028 00004 0069 0.0006 0006 -0.0005 00005 00012 0012 0.0017 0.0023 2000 55.0 2

0.69S5 0,0005 0069 0.0006 -0.0006 -0.0005 00006 0-0013

-0,0013 0.0015 00022 2000 57.5 2

0 6948 0,0005 10 0070 0.0006,-0.00061-0-0006 00006 0.0013

-0,0013 0.0013 0.0021 2000 60.0 2

0,6915 010005 -00070 0.0007 -00007 -0..0006 0.0006 0-0013 0013 0.0011 0.0020 L-10-130 Page 21 of 43 NONPROPRIETARY VERSION OF THE RESPONSE Region 2 CASMO Calculatiom for Fuel Tolerance Uncertainties With Creep Rod Rod Clad Clad' Clad Clad Fuel Fuel Fuel Description Ref Case Pitchi Pitch-OD+

OD -

ID +

ID -

Pellet Pellet Pellet En OD +

OD-

+/-

Stat.

Bubv a

Inp-t Fite Combo PPM GWDb-ca-Eur bv-cf-c-bv-cfd-

"cfte-bv-cftf-bv-cftg-bv-cfth-bv-cfli-35 plz~m W~i Embv-cfm 35-L-cflb

-20 3-NMlTU 35-0 35-2000 350005-

_3350 2003 35-2000 35-2000 35-2000 2000 1

2000 MOO0 2000 2000 0.0 3,5 1-1205 0.0009 -0.0121 -0.0014 0M0014 0.0012 -0,0012 0,0000 0.0001 0.0034 0.0040 2000 0.1 3.5 1,1182 0.0009 -0.0120 -0,0014 0.0013 0.0012 -0.0012 -0.0001 0.0000 0.0034 0.0040 2000 2.0 3.5 1.0979 0.0009 -0.0120 -0.0013 0.0013 0.0012 -0.0012 -0.0001 0.0000 0.0034 0.0039 2000 4.0 3.5 1.0811 0.0009 -00119 -0.0013 0.0013 0.00111 -001

-0.0001 0.0000 0.0034 0.0040 2000 6.0 3.5 1.0640 0.0008 -0.0118 -0.0013 0.0013 0,0011 -0.0011 00000 0.0000 0.0035 0.0040 2000 8.0 3.5 1.0473 0.0008 -0.0118 -0.0012 0.0012 0.0011 -0.0011 0.0000

,000 0.000.035 0.0040 2000 10.0 3.5 1.0312 0.0008 -0.0116 -0.0012 0.0012 0.0010 -0.0011 0.0000 0.0000 0.0036 0.0040 2000 11.0 3.5 1.0234 0.0008 -0.0116 -0.0012 0,0012 0.0010 -0.0010 0.0000 0.0000 0.0036 0.0040 2000 12.5 3.5 1.0120 0.0008 -0.0115 -0.0011 0.0011 0.0010 -0.0010 0.0000 0.0000 0.0036 0.0040 2000 15.0 3.5 0.9937 0.00081-0.0113 -0.0011 0.0011 0.0009 -0.0009 0.0001

-0.0001 0.0036 0.0040 2000 17.5 3.5 0.9759 0.0008 -0.0111 -0.0010 0.0010 0.0009 -0.0009 0.0001

-0.0001 0.0037 0,0040 2000 20.0 3.5 0.9586 0..0007 -0.0109 -0.0009 0.0009 0.0008 -0.0008 0.0001

-0.000.2 0.0037 0,0039 2000 22.5 3.5 0.9417 0,0007 -0.0107 -0.00 0.0008 0.0007 -0.0007 0.0002

-0.0002 0.0037 0.0039 2000 25.0 3.5 0.9253 0.0007 -0.0105 -00007 0.0007 00006 -0.0006 0.0003

-0.0003 0.0037 0.0039 2000 27.5 3.5 0.9003 0.0007 -0.0102 -0.0006 0.0006 0.0005 -00006 0.0003

-0.0004 0.0037 0.0039 2000 30.0 3.5 0.8937 0.0007-0.0100 -00005 0.0005 0_0005 -0.0005 0.0004

-0.0004 0.0037 0.0039 2000 32.5 3.5 0.8785 0.00071-0.0098 -0.0005 0.0004 0.0004 -0,0004 0.0005

-0.0005 0.0037 0.0038 2000 35.0 3.5 0.8638 0.0006 -0.0096 -0.0004 0.0003 0.0003 -0.0003 0.0005

-0.0006 0.0037 0.0038 2000 37.5 3.5 0.8495 0.0006 -0.0093 -0.0002 0.0002 0.0002 -010002 0.0006

-0.0006 0.0036 0.0037 2000- 415 3.5 0.8225 0.0006 -0.0090 -0.0001 0.0000 0.0000 0.0000 0.0OOS

-0.0008 0.0035 0.0036 2000 45.0 3.5 0.80P9 0.0006 -0.00S8 0.0000 0.0000 0.0000 0.0000 O.O00S

-0.0008 0.0033 0.0035 2000 47.5 3.5 0.7978 0.0006 -0.0086 0.0001 -0.0001 -0.0001 0.0001 0.0009

-0.0009 0.0032 0.0034 2000 50.0 3.5 0.7863 0.0005 -0.0084 0.0002 -0.0002 -0.0002 0.0002 0.0010

-0.0010 0.0031 0.0033 2000 52.5 3.5 0.7755 0.0005 -0.0083 0.0003 -0,0003 -0.0003 0.0003 0.0010

-0.0010 0.0030 0.0032 2000 55.0 3.5 0.7653 0.0005 -0.0082 0.0004 -0.0004 -0.0003 0.0003 0.0011

-0.0011 0.0028 0.0031 2000 57.5 3.5 0.7558 0.0005 -0.0081 0.0004 -0.0004 -0.0004 0.0004 0.0011

-0.0011 0.0027 0.0030 12000 60.0 3.5 0.7469 0.0005 -0.0080 0.0005 -0.0005 -0.0004 0.0004 0.0012

-0.0012 0.0025 0.0029 L-1 0-130 Page 22 of 43 NONPROPRIETARY VERSION OF THE RESPONSE Region 2 CASMO Calculations forFitel Tolerance Uncertainties With Creep

~

j Fuel Fuel Fuel Rd Ro~d Clad Clad Clad Clad 1ul Fel Fe Description Ref Case Pit Pit OD +

Ol+

D Pellet Pellet Pellet En Pitch + Pitch -

OD +

OD -

ID +

I I

OD-+

OD--

+DSta0.

___r__p Input File

~~bv-cfta bv-cftl

-- te-

¢*b ppm GWDI Ear bv-cftn-bv-cft by-cflb-b0-yc-cfid-bv-cft1.- bvy-fge-bv-cfth-- bv-cfli-5(

MTU 50-0 2000 50-2000 2000 50-2000

-000 50-2000 50-2000 50-2000 2000 2000 0.0 5

1.2003 0.0010 -0.0146 -0.0014 0.0014 0.0013 -0.0012 -0.0001 0.0002 0.0021 0.0030 1000 0.1 5

1.1985 0.0010 -0.0146 -0.0014 0.0014 0.0012 -0.0012 -0.0002 0.0002 0.0021 0.0030 2000 2.0 5

1.1775 0.0010 -0.0145 -0.0014 0.0014 0.0012 -0.0012 -0.0002 0.0002 0.0021 0.0030 2000 4.0 5

1.1624 0.001.0 -0.0144 -0.0014 0.0014 0.0012 -0.0012 -0.0002 0.0002 0.0021 0.0030 2000 6,0 5

1.1471 0.0010 -0.0143 -0.0014 0.0014 0.0012 -0.0012 -0.0002 0.0002 0-0022- 0.0030 M2000 80 5

1.1320 0.0010 -0.0142 -00014 0.0014 0.0012 -0.0012 -0.0002 0.0002 0.002 0.0030 2000 10.0 5

1.1173 0.0010 -0.0141 -0.0014 0.0014 0.0012 -0.0012 -0.0002 0.0002 0.0023 0.0031 2000 11.0 5

1.1102 0.0010 -0.0140 -0,0014 0.0013 0.0012 -0.0012 -0.0002 0.0002 0.0023 0.0031 2000 12.5 5

1.0997 0.0010 -00139 -0.0013 0.0013 0.0012 -0.0012 -0.0002 0.0002 0.00 0.0031 2000 15.0 5

1.0828 0.0009 -0.0138 -0.0013 0.0013 0.0011 -0.0011

-0.0001 0.0002 0.0024 0.0031 2000 17.5 5

1.0264 0.0009 -0.0136 -0M.0013 0.0012 0.0011 -0.0011

-0.0001 0.0001 0.0024 0.0031 2000 20.0 5

1.0504 0.0009 -0.0135 -0.0012 0.0012 0.0011

-0.0011 -0.0001 0.0001 0.0025 0.0031 2000 22.5 5

1.0348 0.0009 -0.0133 -0.0012 0.0011 0.0010 -0.0010 -0.0001 0.0001 0.0025 0.0031 2000 25.0 5

1.0196 0.0009 -0.0131 -0.0011 0.0011 0.0010 -0.0010 -0.0001 0.0000 0.0026 0.0031 2000 27.5 5

1M0046 0.0009 -0.0129 -0.0011 0.0010 0.0009 -0.0009 0.0000 0.0000 0.0026 0.0031 2000 30.0 5

0.989S 0.0008 -0.0127 -0.0010 0.0010 0.0009 -0.0009 0.0000 0.0000 0.0027 0.0031 2000 32.5 5

0.9751 0.0008 -0.0125 0009 0.0009 0.0008 -0.0008 0.0001

-0.0001 0.0027 0.0031 2000 35.0 5

0.9607 0.0008 -0.0123 -0.0009 0.0008 0.0008 -0.0008 0.0001

-0.0001 0.0028 0.0031 2000 37.5 5

0-9464 0.0008 -0.0121 -0.0008 0.0008 0.0007 -0.0007 0.0002

-0.0002 0.0028 0.0031 2000 42.5 5

0.9184 0.0008 -0.0116 -0.0006 0.0006 0.0006 -0.0005 0.0003

-0,0003 0.0028 0.0031 2000 45.0 5

0.9047 0.0007 -0.0114 -0.0005 0.0005 0.0005 -0.0005 0.0003

-0.0003 0.0029 0.0030 20001 47.5 5

0.8912 0.0007 -0.0111 -0.0005 0.0005 0.0004 -0.0004 0.0004

-0.0004 0.0029 0.0030 2000 50.0 5

0.8779 0.0007 -0.0109 -0.0004 0.0004 0.0003 -0.0003 0.0005

-0.0005 0.0028 0.0030 2000 52.5 5

0.8650 0.0007 -0.0107 -0.0003 0.0003 0.0003 -0.0002 0.0005

-0.0005 0.0029 0.0030 2000 55.0 5

0.8523 0.0007 -0.0105 -0.0002 0.0002 0.0002 -0.0002 0.0006

-0.0006 0.0028 0.0030 2000 57.5 5

0.S400 0.0006 -0.0102 A0.0001 0.0001 0.0001 -0.0001 0.0007

-0.0007 0.0028 0.0029 2000 60.0 5

0.8280 0.0006-0.0100 0.0000 0.0000 0.0000 0.0000 0.0007

-0.0008 0.0027 0.0029

28. Section 4.7.8 discussed temperature and water density effects. Clarify the source of the bias, the method by which the bias is calculated, and the justification for using CASMO to estimate the bias. Confirm that the calculational results shown in Table 4.7.15 reflect changes in both water density and temperature. Discuss how the temperature bias changes with the presence of soluble boron. If appropriate, include a revised temperature bias for soluble boron crediting.

Response

The source of the bias is related to the temperature at which the cross sections are evaluated in MCNP4a and the temperature at which the analysis is performed in MCNP4a. CASMO-4 is used to estimate the bias because the moderator temperature is easily changed in CASMO-4 (thus making it useful for parametric studies), and the water density is calculated by the CASMO-4 code for the given water temperature. The CASMO-4 benchmark that was provided as Enclosure A to the letter dated June 15, 2009, includes experiments at various temperatures, L-1 0-130 Page 23 of 43 NONPROPRIETARY VERSION OF THE RESPONSE demonstrating that CASMO-4 adequately models the effects of changing moderator temperature. Additional explanation is provided below. With respect to the results of the moderator temperature coefficient calculations presented in Table 4.7.15 of the Holtec Licensing Report, those results reflect both changes in moderator density and temperature. These results are used to determine the most reactive moderator density for use in MCNP keff calculations.

The effect of soluble boron on the temperature bias is shown in the table below. The results show that the temperature bias decreases with borated water, and therefore pure water bounds that for borated water. The results presented in the table below were calculated using the methodology explained in greater detail below.

L-1 0-130 Page 24 of 43 NONPROPRIETARY VERSION OF THE RESPONSE (Thlriilntinn of t1~e T~rnn~rnhhzTe Bi~ CASMO4 paraleter T = 39.2 F T = 80.33 F va % U235 ppm gx%,dnu inut file kinf input file delta kinf 2

0 0.0 bv-pftb2-20-0 0.9688 bv-pftb3-20-O

-0.0043 2

0 10.0 bv-pftb2-20-0 0.8926 bv-pffb3-20-0

-0.0027 2

0 20.0 bv-pftb2-20-0 0.8312 bv-pffb3-20-0

-0.0017 2

0 30.0 bv-pflb2-20-0 0.7836 bv-pftb3-20-0

-0.0009 3

0 0.0 bv-pftb2-30-0 1.0818 bv-pftb3-30-0

-0.0035 3

0 10.0 bv-pftb2-30-0 0.9940 b-v-pftb3-30-0

-0.0028 3

0 20.0 bv-pftb2-30-0 0.9242 bv-pftb3-30-0

-0.0022 3

0 30.0 bv-pftb2-30-0 0.8641 bv-pftb3-30-0

-0.0015 3

0 40.0 bv-pftb2-30-0 0.8135 bv-pffb3-30-0

-0.0010 4

0 0.0 bv-pftb2-40-0 1.1519 bv-pftb3-40-0

-0.0029 4

0 10.0 bv-pftb2-40-O 1.0654 bv-pfib3-40-0

-0.0027 4

0 20.0 bi-pftb240-0 0.9967 bv-pfb340-

-00023 4

0 30.0 bv-pftb2-40-0 0.9358 bv-pf3-40-0

-0.0019 4

0 40.0 bv-pfb2-40-0 0.8804 bv-pffb3-40-0

-0.0014 5

0 0.0 bv-pftb2-50-0 1.2004 I,-pftb3-50-0

-0.0025 5

0 10.0 bv-pftb2-50-0 1.1178 bv-pffbo3-50-0

-0.0025 5

0 20.0 bv-pftb2-50-0 1.0524 bv-pftb3-50-0

-0.0023 5

0 30.0 bvL-pftb2 0.9939 bv-pftb3-50-_

-0.0020 5

0 40.0 bv-pftb2-50-0 0.9393 bv-pf~t3-50-0 0017 5

0 50.0 bv-pftb2-50-0 0.8883 bv-pfo3-50-0

-0.0013 5

0 60.0 bv-pftb2-50-0 0.8418 bv-pftb3-50-O

-0.0010 2

2000 0.0 bv-pftb2-20-2000 0.7044 bv-pftb3-20-20

-0.0020 2

2000 10.0 bv-pftb2-20-2000 0.6744 bv-pftb3-20-20

-0.0005 2

2000 20.0 bv-pt~b2-20-2000 0.6360 bv-pftb3-20-20

-0.0003 2

2000 30.0 bv-pftb2-20-2000 0.6044 bv-pftb3-20-20 0.0007 3

2000 0.0 bv-pftb2-30-2000 0.8340 bv-pflb3-30-20

-0.0006 3

2000 10.0 bv-pfb2-30-2000 0.7807 bv-pftb3-30-20O

-0.0008 3

2000 20.0 bv-pftb2-30-2000 0.-790 bv-pftb3-30-2001

-0.0002 3

2000 30.0 bv-pftb2-30-2000 0.6828 bv-pftb3-30-20 0.0002 3

2000 40.0 bv-pftb2-30-2000 0.6436 bv-pftb3-30-20 0,0006 4

2000 0.0 bv-pftb2-40-2000 0.9228 bv-pftb3-40-20

-0.0013 4

2000 10.0 bv-pftb2-40-2000 0.8626 bv-pftb340-20(

-0.0009 4

2000 20.0 bv-pftb2-40-2000 0.8079 bv-pftb3-40-20

-0.0095 4

2,000 30.0 bv-plftb2-40-2000 0.7579 bv-pfltb3-40-20

--0.0002 4

2000 40.0 by-pib2-40-2000 0.7114 bv-pftt3-40-20 0.0002 5

2000 0.0 bv-pftb2-_S0-2000 0.9880 bv-pftb3-50-20

-0.0010 5

2000 0.0 bv-pftb2-50-2000 0.9265 bv-pft3-50-20

-0.0009 5

2000 20.0 bv-pftb2-50-2000 0.9721 bv-pftb3-50-20

-0.0006 5

2000 30.0 bv-pftb2-50-2000 0.8218 bv-pftb3-50-20

-0.0004 5

2000 40.0 bv-pftb2-50-2000 0.7742 bv-pftb3-50-200C

-0.0001 5

2000 50.0 bv-pftb2-50-2000 0.7297 bv-pftb3-50-20 0.0002 5

2000 50.0 bv-pftb2-50-2000 0.6895 bv-pftb3-50-20 0.0004 nmM

-0.0043 L-10-130 Page 25 of 43 NONPROPRIETARY VERSION OF THE RESPONSE i((PROPRIETARY -

I L-10-130 Page 26 of 43 NONPROPRIETARY VERSION OF THE RESPONSE L-10-130 Page 27 of 43 NONPROPRIETARY VERSION OF THE RESPONSE 0

The cases and calculations presented above allow the following conclusions:

0 MPROPRIETARY -

" The temperature bias determined with CASMO-4 for a low temperature essentially bounds that determined with MCNP.

" (([PROPRIETARY-Additional sensitivity calculations were performed to calculate the temperature bias using CASMO-4. The results are presented in the table on page 24 entitled "Calculation of the Temperature Bias CASMO-4," and show that the temperature bias L-10-130 Page 28 of 43 NONPROPRIETARY VERSION OF THE RESPONSE is 0.0043. This new temperature bias uses the above discussed methodology and is larger than the temperature bias in the LAR because the new calculations fix the moderator density to match that used in MCNP4a calculations and include calculations that cover the range of initial enrichment and burnup combinations.

This revised bias will be included in the determination of the final burnup versus enrichment values in a future supplement to the LAR.

L-10-130 Page 29 of 43 NONPROPRIETARY VERSION OF THE RESPONSE

(([PROPRIETARY -

L-10-130 Page 30 of 43 NONPROPRIETARY VERSION OF THE RESPONSE L-10-130 Page 31 of 43 NONPROPRIETARY VERSION OF THE RESPONSE L-10-130 Page 32 of 43 NONPROPRIETARY VERSION OF THE RESPONSE L-1 0-130 Page 33 of 43 NONPROPRIETARY VERSION OF THE RESPONSE L-1 0-130 Page 34 of 43 NONPROPRIETARY VERSION OF THE RESPONSE 1]

L-10-130 Page 35 of 43 NONPROPRIETARY VERSION OF THE RESPONSE

33. It appears that the purpose of Tables 4.7.8 and 4.7.10 is to produce an estimate for the bias introduced by not modeling the IFBA and the IFBAs with WDRs during the depletion calculations, Since the storage racks do not take credit for the presence of IFBA, it would seem that this table should show only the impact of the presence of IFBA during the depletion calculations. All of the results should have been restarts in the rack geometry with IFBA B-10 and WDRs removed. Consequently all "Ref."

values and associated k. values at zero burnup should have been the same.

It also appears that the columns for IFBA with four and eight WDRs includes the IFBA B-10. This creates large negative Ak values in the last column. So this approach uses the IFBA B-10 to reduce the Ak values, thus indirectly taking credit for IFBA B-10. This is probably not appropriate without further justification. Justify crediting the residual IFBA B-10 in the calculation of the depletion bias.

The calculations were done only with fuel having initial enrichment of 3.4 wt%. Justify not performing the calculations for the range of initial enrichments and IFBA loadings permitted.

Response

This response is applicable to both RAI item 33 and RAI item 34.

Tables 4.7.8 through 4.7.10 in the Holtec Licensing Report calculate the reactivity bias associated with the use of integral and non-integral absorbers or reactivity control devices. The calculations shown in Table 4.7.8 through 4.7.10 are not used for any other purpose other than to determine the reactivity bias that is applied to the final keff. No credit is taken for the presence of either integral or non-integral absorbers in calculations to determine keff in the spent fuel storage rack calculations.

Instead, the maximum positive difference from the results of the calculations shown in Tables 4.7.8 through 4.7.10 is applied as a reactivity bias to keff. Therefore, the restarts in the storage rack geometry are only applicable to the determination of the bias.

Non-integral reactivity devices (WABA) are separate rods that can be inserted and removed from the fuel, and, therefore, may not be physically present in the storage rack geometry. However, integral absorbers (IFBA) are by definition part of the fuel pellet. The peak reactivity effect is expected after the removal of WABA rods and after the depletion of the initial IFBA B-10 content. Therefore, the IFBA cases were calculated with the IFBA included in the composition within the rack geometry as it is physically impossible to remove. However, additional sensitivity calculations are presented here to demonstrate that removing the IFBA for the restart calculation has no impact (in CASMO-4 this is done by setting the B-10 concentration for the IFBA layer to zero). However, IFBA is not credited because the results are used to L-10-130 Page 36 of 43 NONPROPRIETARY VERSION OF THE RESPONSE determine a reactivity bias that is applied as a penalty to the final keff, not in the determination of a kcaic or isotopic compositions.

Additional calculations were also performed and the results are presented below for the IFBA case to demonstrate that the calculations that were presented in Table 4.7.8 of the Holtec Licensing Report were the bounding configuration.

CASMO-4 Results for Reactivity Comparison of Calculations with and without I FBA Reference Case (no IFBA)

IFBA (IFBA B-10 removed in storage rack IFBA Delta kinf Delta kinf gwd/

(I FBA -

(IFBA -

mtu wt%

Input File kinf

  1. IFBA Input File kinf no IFBA) # FBA Input File kinf no IFBA) 10 3

bv-dep-30-0-rack-creep 0.9940 100 bv-ifbal0O-out-30-0 0.9955 0.0015 100 bv-ifbalOO-30-0-rack-cree 0.9670

-0.0271 15 3

bv-dep-30-0-rack-creep 0.9577 100 bv-ifbalOO-out-30-0 0.9598 0.0020 100 bv-ifbalOO-30-0-rack-cree 0.9499

-0.0079 20 3

bv-dep-30-0-rack-creep 0.9242 100 bv-ifbalOO-out-30-0 0.9263 0.0021 100 bv-ifbalOO-30-0-rack-cree 0.9231

-0.0011 25 3

bv-dep-30-0-rack-creep 0.8930 100 bv-ifbalOO-out-30-0 0.8951 0.0021 100 bv-ifbalOO-30-0-rack-cree 0.8941 0.0011 30 3

bv-dep 0-rack-creep 0.8641 100 bv-ifbalO0-out-30-0 0.8661 0.0020 100 bv-ifbal00-30-0-rack-cree 0.8658 0.0017 45 3

bv-dep-30-0-rack-creep 0.7920 100 bv-ifbalOO-out-30-0 0.7935 0.0015 100 bv-ifbal00-30-0-rack-cree 0.7935 0.0015 60 3

bv-dep-30-0-rack-creep 0.7430 100 bv-ifbal00-out-30-0 0.7438 0.0008 100 bv-ifbal00-30-0-rack-cree 0.7438 0.0008 10 4

bv-dep-40-0-rack-creep 1.0655 100 bv-ifbalOO-out-40-0 1.0650

-0.0004 100 bv-ifbal00--40-0-rack-cree 1.0258

-0.0396 15 4

bv-dep-40-0-rack-creep 1.0298 100 bv-ifbal00-out-40-0 1.0301 0.0002 100 bv-ifbal00-40-0-rack-cree 1.0126

-0.0173 20 4

bv-dep-40-0-rack-creep 0.9967 100 bv-ifbalOO-out-40-0 0.9973 0.0006 100 bv-ifbal00-40-0-rack-cree 0.9899

-0.0068 25 4

bv-dep-40-0-rack-creep 0.9655 100 bv-ifbalOO-out-40-0 0.9663 0.0008 100 bv-ifbal00-40-0-rack-creed 0.9633

-0.0022 30 4

bv-dep-40-0-rack-creep 0.9358 100 bv-ifbalO0-out-40-0 0.9367 0.0009 100 bv-ifbal00-40-0-rack-creeý 0.9355

-0.0003 45 4

bv-dep-40-0-rack-creep 0.8550 100 bv-ifbal0O-out-40-0 0.8561 0.0011 100 bv-ifbal00--40-0-rack-creed 0.8560 0.0010 60 4

bv-dep-40-0-rack-creep 0.7900 100 bv-ifbal0O-out-40-0 0.7910 0.0009 100 hv-ifbal00-40-0-rack-cree 0.7910 0.0009 10 5

bv--dep-50-0-rack-creep 1.1178 100 bv-ifbalOO-out-50-0 1.1163 -0.0015 100 bv-ifbalOO-50-0-rack-cree 1.0701

-0.0477 15 5

bv-dep-50-0-rack-creep 1.0840 100 bv-ifbalO0-out-50-0 1.0830 -0.0010 100 bv-ifbal0O-50-0-rack-creeli 1.0589

-0.0251 20 5

bv-dep-50-0-rack-creep 1.0524 100 bv-ifbal0O-out-50-0 1.0518 -0.0006 100 bv-ifbalO0-50-0-rack-creep 1.0398

-0.0126 25 5

bv-dep-50-0-rack-creep 1.0226 100 bv-ifbalOO-out-50-0 1.0223 -0.0003 100 bv-ifbal0O-50-0-rack-cree 1.0165

-0.0061 30 5

bv-dep-50-0-rack-creep 0.9940 100 bv-ifbalOO-out-50-0 0.9939 -0.0001 100 bv-ifbalOO-50-0-rack-creer 0.9911

-0.0028 45 5

bv-dep-50-0-rack-cree 0.9133 100 bv-ifbal00-out-50-0 0.9137 0.0004 100 bv-ifbal00-50-0-rack-cree 0.9134 0.0001 60 5

bv-dep-50-0-rack-creep 0.8419 100 bv-ifbal0O-out-50-0 0.8424 0.0005 100 bv-ifbal00-50-0-rack-creer 0.8424 0.0005 10 3.8 bv-dep-38-0-rack-creep 1.0530 200 bv-ifba200-out-38-0 1.0534 0.0005 200 bv-ifba200-38-0-rack-creer 0.9878

-0.0652 15 32 8 bv-dep-38-0-rack-creep 1.0171 200 bv-ifba200-out-38-0 1.0188 0.0017 200 bv-ifba200-38-5-ack-cree 0.9907

-0.0263 20 3.8 bv-dep-38-0-rack-creep 0.9837 200 bv-ifba200-out-38-0 0.9861 0.0023 200 bv-ifba200-38-0-rack-creef 0.9747

-0.0091 25 3.8 bv-dep-38-0-rack-creep 0.9524 200 bv-ifba200-out-38-0 0.9550 0.0026 200 bv-ifba200-38-0-rack-creel 0.9506

-0.0018 30 3.8 bv-dep-38-0-rack-creep 0.9226 200 bv-ifba200-out-38-0 0.9254 0.0028 200 bv-ifba200-38-0-rack-creed 0.9237 0.0011 45 3.8 bv-dep-38-0-rack-creep 0.8426 200 bv-ifba200-out-38-0 0.8455 0.0029 200 bv-ifba200-38-0-rack-creed 0.8454 0.0028 60 3.8 bv-dep-38-0-rack-creep 0.7800 200 bv-ifba200-out-38-0 0.7823 0.0023 200 bv-ifba200-38-0-rack-creed 0.7823 0.0023 10 4.5 bv-dep-45-0-rack-creep 1.0935 200 bv-ifba200-out-45-0 1.0922 -0.0013 200 bv-ifba200-45-0-rack-cree 1.0161

-0.0775 15 4.5 bv-dep-45-O-rack-creep 1.0587 200 bv-ifba200-out-45-0 1.0586

-0.0001 200 bv-ifba200-45-0-rack-creeF 1.0218

-0.0370 20 4.5 bv-dep-45-O-rack--creeo 1.0263 200 bv-ifba200-out-45-0 1.0270 0.0006 200 bv-ifba200-45-0-rack--cree:

1.0100

-0,0164 25 4.5 bv-dep-45-0-rack-creep 0.9958 200 bv-ifba200-out-45-0 0.9969 0.0011 200 bv-ifba200-45-0-rack-creel 0.9893

-0.0065 30 4.5 bv-dep-45-0-rack-creep 0.9665 200 bv-ifba200-out-45-0 0.9679 0.0014 200 bv-ifba200-45-0.-rack-creec 0.9646

-0.0018 45 4.5 bv-dep-45-0-rack-creep 0.8851 200 bv-ifba200-out-45-0 0.8871 0.0020 200 bv-ifba200--45-0-rack-creeF 0.8869 0.0018 60 4.5 bv-dep-45-0-rack-creep 0.8159 200 bv-ifba200-out-45-0 0.8180 0.0021 200 bv-ifba200-45-0-rack-cree d

0.8179 0.0020 10 4.5 bv-dep-45-0-rack-creep 1.0935 200 bv-ifba200-out 0

1.0922

-0.0013 200 bv-ifba200-45-0-rack-cree 1.0161

-0.0775 15 4.5 bv-dep-45-0-rack-creep 1.0587 200 bv-ifba200-out-45-0 1.0586

-0.0001 200 bv-ifba200-45-0-rack-cree

ý 1.0218

-0.0370 20 4.5 bv-dep-45-0-rack-creep 1.0263 200 bv-ifba200-out-45-0 1.0270 0.0006 200 bv-ifba200-45-0-rack-cree 1.0100

-0.0164 25 4.5 bv-dep-45-0-rack-creep 0.9958 200 bv-ifba200-out-45-0 0 29969 0.0011 200 bv-ifba200-45-0-rack-cree d

0.9893

-0.0065 30 4.5 bv-dep-45-0-rack-creep 0.9665 200 bv-ifba200-out-45-0 0.9679 0.0014 200 bv-ifba200-45-0-rack-cree 0.9646

-0.0018 45 4.5 bv-dep-45-0-rack-creep 0.8851 200 bv-ifba200-out-45-0 0.8871 0.0020 200 bv-ifba200-45-0-rack-cree 0.8869 0.0018 60 4.5 bv-dep-45-0-rack-creep 0.8159 200 bv-ifba200-out-45-0 0.8180 0.0021 200 bv-ifba200-45-0-rack-cree 0.8179 0.0020 251.51 vde-4-0rakcre.95820 v-fb20-ut max

.96 0.001129 0

maxba0-5--ak-re 0 8 0.0028 max 0.0029 max 0.0028 L-10-130 Page 37 of 43 NONPROPRIETARY VERSION OF THE RESPONSE Results of the CASMO-4 Calculations ofthe IFBA Bias IFBA Pins 0

0 0

100 100 128 128 200 200 wt% U-235 30 38 50 30 30 38

  • 10 50 50 50 input file/

bvdba5-bvdba5-bvdba5-bvifbalO delta bvifbalO delta bvifbal2 delta bvifbal2 delta bvifba20 delta bvifba20 delta max delta gwd/mtu 30 38 50 0-30-rai kinf O-50-rai kinf 8-30-rai kinf 8-50-rai kinf 0-38-rai kinf 0-50-rai kinf kinf 0.0 1.0779 1.1358 1.1958 0.8918

-0.1860 1.0450

-0.1508 0.8433

-042346 1.0006

-0.1952 0.8405

-0.2953 0.9276

-0.2682

-0.1508 0.1 1.0754 1.1336 1.1940 0.8924

-0.1830 1.0448 -0.1492 0.8447

-0.2306 1.0010

-0.1931 0.8423

-0.2913 0.9287

-0.2653

-0.1492 2.0 1.0560 1.1131 1.1732 0.9255

-0.1304 1.0534

-0.1197 0.8924

-0.1635 1.0190

-0,1542 0.8912

-0.2219 0.9598

-0.2134

-0.1197 4.0 1.0389 1.0967 1.1581 0.9491

-0.0899 1.0629

-0.0952 0.9272

-0.1117 1.0364

-0.1217 0.9313

-0.1654 0.9884

-0.1697

-0.0899 6.0 1.0215 1.0799 1.1427 0.9613

-0.0603 1.0678

-0.0749 0.9474 -0.0741 1.0477

-0.0950 0.9589

-0.1211 1.0092

-0.1336 -0.0603 8.0 1.0046 1.0636 1.1277 0.9654

-0.0392 1.0692

-0.0584 0.9571

-0.0475 1.0543

-0.0734 0.9767

-0.0869 1.0237

-0.1040

-0.0392 10.0 0.9885 1.0478 1.1130 0.9638

-0.0247 1.0679

-0.0451 0.9591

-0.0294 1.0570

-0.0560 0.9868

-0.0611 1.0330

-0.0800

-0.0247 11.0 0.9806 1.0402 1.1059 0.9614

-0.0192 1.0665

-0.0395 0.9580 -0.0226 1.0572

-0.0487 0.9895

-0.0508 1.0360

-0.0699 -0.0192 12.5 0.9692 1.0290 1.0955 0.9564

-0.0128 1.0633

-0.0321 0.9544

-0.0148 1.0561

-0.0393 0.9911

-0.0380 1.0387

-0.0567 -0.0128 15.0 0.9509 1.0111 1.0787 0.9452

-0.0057 1.0562

-0.0225 0.9447

-0.0062 1.0516 -0.0270 0.9888

-0.0223 1.0393

-0.0394

-0.0057 17.5 0.9331 0.9936 1.0623 0.9316

-0.0015 1.0470

-0.0153 0.9319

-0.0012 1.0443

-0.0181 0.9816

-0.0120 1.0358

-0.0266 -0.0012 20.0 0.9160 0.9767 1.0465 0.9168 0.0009 1.0363

-0.0101 0.9175 0,0016 1.0348

-0.0117 0.9714

-0.0053 1.0291

-0.0173 0.0016 22.5 0.8993 0.9602 1.0310 0.9015 0.0022 1.0246

-0.0064 0.9024 0.0031 1.0239

-0.0071 0.9592

-0.0010 1.0203

-0.0107 0.0031 25.0 0.8833 0.9441 1.0159 0.8862 0.0029 1.0121

-0.0038 0.8871 0.0039 1.0119

-0.0040 0.9458 0.0017 1.0098

-0.0061 0.0039 27.5 0.8677 0.9284 1.0010 0.8710 0.0033 0.9991

-0.0019 0.8720 0.0043 0.9993

-0.0018 0.9317 0.0033 0.9982

-0.0028 0.0043 30.0 0.8528 0.9130 0.9863 0.8562 0.0034 0.9858 -0.0006 0.8572 0.0045 0.9861

-0.0003 0,9174 0.0044 0.9858

-0.0005 0.0045 32.5 0.8384 0.8980 0.9719 0.8419 0.0035 0.9722 0.0003 0.8429 0.0045 0.9727 0.0008 0.9030 0.0050 0.9729 0.0011 0.0050 35.0 0.8247 0.8833 0.9576 0.8281 0.0035 0.9585 0.0010 0.8291 0.0044 0.9591 0.0015 0.8887 0.0054 0.9598 0.0022 0.0054 37.5 0.8116 0.8690 0.9435 0.8150 0.0034 0.9449 0.0014 0.8159 0.0044 0.9455 0.0020 0.8746 0.0056 0.9465 0.0030 0.0056 40.0 0.7991 0.8551 0.9296 0.8024 0.0033 0.9313 0.0017 0.8034 0.0042 0.9319 0.0024 0.8608 0.0057 0.9331 0.0035 0.0057 42.5 0.7873 0.8417 0.9158 0.7906 0.0032 0.9178 0.0020 0.7914 0.0041 0.9184 0.0026 0.8474 0.0058 0,9197 0.0039 0.0058 45.0 0.7763 0.8287 0.9023 0.7794 0.0031 0.9044 0.0021 0.7802 0.0039 0.9051 0.0028 0.8344 0.0057 0,9065 0.0042 0.0057 47.5 0.7659 0.8162 0.8890 0.7688 0.0030 0.8912 0,0022 0.7696 0.0038 0.8919 0.0029 0.8219 0.0057 0.8934 0.0044 0.0057 50.0 0.7562 0.8043 0.8760 0.7590 0.0028 0.8783 0.0023 0.7598 0.0035 0.8789 0.0030 0.8098 0.0056 0,8805 0.0045 0.0056 52.5 0.7473 0.7929 0.8632 0.7499 0.0027 0.8655 0.0023 0.7506 0.0034 0.8662 0.0030 0.7983 0.0055 0,8678 0.0046 0.0055 55.0 0.7390 0.7821 0.8507 0.7415 0.0025 0.8531 0.0024 0.7421 0.0032 0.8538 0.0031 0.7873 0.0053 0,8554 0.0046 0.0053 57.5 0.7314 0.7718 0.8386 0.7337 0.0023 0.8410 0.0024 0.7343 0.0030 0.8417 0.0031 0.7770 0.0051 0.8433 0.0046 0.0051 60.0 0.7244 0.7622 0.8269 0.7266 0.0022 0.8292 0.0024 0.7272 0.0028 0.8299 0.0031 0.7671 0.0049 0.8315 0.0046 0.0049 max 0.0058 L-10-130 Page 38 of 43 NONPROPRIETARY VERSION OF THE RESPONSE With respect to RAI 34, additional calculations were performed with the WABA cases to demonstrate that the peak reactivity effect is the same even when the WABA rods are left in the rack model. This is done because in the LAR Table 4.7.11 calculations the WABA rods were left in the rack model during restart calculations. Calculations were performed with the WABA removed during the restart to demonstrate that the calculations in Table 4.7.11 (maximum value of 0.0062) captured the bounding result.

Results of the CASMO-4 Calculations of WABA Bias Dependence on Number of WABA Rods and Fuel Enrichment (WABA removed for rack restart)

WABA Rods 0

12 20 n/a 0

12 1

16 nla Enrichment 2.6 3.0 wt% U-235 In put File bvdb5-bvwabal bvwaba2 bvdb5-30 bvwabal bvwabal Inputile 26 2-26-rai 0-26-rai Delta-k 2-30-rai 6-30-rai Delta-k Burnup (max -

(max -

Max (GWD/MTU)

Ref k-inf k-inf ref)

Ref k-inf k-inf ret)

Delta-k 0.0 1.0400 1.0400 1.0400 0.0000 1.0779 1.0779 1.0779 0.0000 0.0000 0.1 1.0373 1.0373 1.0374 0.0000 1.0754 1.0754 1.0754 0.0000 0.0000 2.0 1.0192 1.0198 1.0203 0.0011 1.0560 1.0564 1.0566 0.0006 0.0011 4.0 1.0022 1.0034 1.0043 0.0021 1.0389 1.0398 1.0401 0.0012 0.0021 6.0 0.9849 0.9867 0.9879 0.0030 1.0215 1.0229 1.0233 0.0018 0.0030 8.0 0.9680 0.9704 0.9719 0.0038 1.0046 1.0065 1.0070 0.0024 0.0038 10.0 0.9520 0.9547 0.9565 0.0045 0.9885 0.9907 0.9913 0.0029 0.0045 11.0 0.9442 0.9470 0.9489 0.0047 0.9806 0.9829 0.9836 0.0030 0.0047 12.5 0.9328 0.9359 0.9379 0.0051 0.9692 0.9717 0.9725 0.0033 0.0051 15.0 0.9147 0.9182 0.9205 0.0058 0.9509 0.9538 0.9547 0.0038 0.0058 17.5 0.8972 0.9009 0.9034 0.0062 0.9331 0.9363 0.9373 0.0041 0.0062 20.0 0.8804 0.8840 0.8863 0.0060 0.9160 0.9191 0.9200 0.0041 0.0060 22.5 0.8642 0.8676 0.8698 0.0055 0.8993 0.9023 0.9032 0.0039 0.0055 25.0 0.8488 0.8519 0.8540 0.0052 0.8833 0.8861 0.8869 0.0037 0.0052 27.5 0.8340 0.8370 0.8389 0.0049 0.8677 0.8704 0.8712 0.0035 0.0049 30.0 0.8200 0.8227 0.8246 0.0047 0.8528 0.8554 0.8562 0.0034 0.0047 32.5 0.8066 0.8093 0.8111 0.0044 0.8384 0.8409 0.8417 0.0033 0.0044 35.0 0.7940 0.7965 0.7983 0.0042 0.8247 0.8271 0.8279 0.0032 0.0042 37.5 0.7822 0.7846 0.7862 0.0040 0.8116 0.8139 0.8146 0.0031 0.0040 40.0 0.7712 0.7734 0.7750 0.0038 0.7991 0.8013 0.8021 0.0030 0.0038 max 0.0062 With respect to the range of enrichments and device loading, the fuel assemblies used at BVPS-2 have either had no integral or non-integral reactivity control devices or have had one of the following configurations with respect to integral and non-integral reactivity control devices: water displacement rods (WDR), WABA, IFBA, and IFBA and WDR configurations. No other types have been used or are anticipated to be used. As committed to in the letter dated March 18, 2010, a process is being established to ensure that the design features and operating parameters of fuel used in the future at BVPS-2 are consistent with the assumptions of the criticality analysis.

L-10-130 Page 39 of 43 NONPROPRIETARY VERSION OF THE RESPONSE The following table summarizes the use of integral and non-integral absorbers, and includes assembly enrichment for each case:

Listing of the Range of Integral and Non-integral Absorber Configurations Region Enrichment wt% U-235 (Integral or Non-integral) 1 2.105 0

2, 2A 2.602 12, 16, 20 WABA locations 3

3.099 12, 16 WABA locations 3.407 100 IFBA and 4 WDR 3.407 128 IFBA 3.407 128 IFBA and 8 WDR 3.798 100 IFBA and 4 WDR 3.798 128 IFBA 3.798 128 IFBA and 4 WDR 3.798 32 IFBA 3.798 64 IFBA 3.599 128 IFBA 5A, 5B, 5C 3.820 128 IFBA 4.201 0, 100, 128 IFBA 3.607 64, 80, 128 IFBA 4.015 0, 80 IFBA 3.604 0, 48, 128 IFBA 4.008 48, 80 IFBA 3.608 64, 80, 128 IFBA 4.210 64, 128 IFBA 4.012 64, 128 IFBA 4.401 64, 104, 128 IFBA 3.804 80, 104, 128 IFBA 4.193 64 IFBA 4.201 0, 80, 128 IFBA 4.801 32,104 IFBA 4.201 128 IFBA 4.795 48, 64, 104, 128 IFBA 4.397 48, 104 IFBA 4.946 48, 104 IFBA 4.196 32, 104 IFBA 4.787 48, 104 IFBA 4.600 32, 128 IFBA 4.950 80, 104, 128 IFBA 4.400 64, 104, 128 IFBA 4.950 64, 104 IFBA 4.200 80, 104, 128 IFBA 4.800 64, 80 IFBA L-1 0-130 Page 40 of 43 NONPROPRIETARY VERSION OF THE RESPONSE Summarizing the above table:

WABA enrichment range:

2.602 to 3.099 weight percent U-235 WDR enrichment range:

3.407 to 3.798 weight percent U-235 IFBA enrichment range:

3.407 to 4.950 weight percent U-235 Based on the data presented in the above table, the calculation results shown in Tables 4.7.8 through 4.7.10 cover the range of device loading and fuel assembly enrichments. Therefore, the calculation results in Tables 4.7.8 through 4.7.10 present the subset of possibilities that demonstrate the bounding configurations.

Based on the information presented in the above table, initial enrichment and integral and non-integral configurations were selected to show trends in reactivity effect with respect to loading and enrichment, and also to bound the range of possible configurations. Table 4.7.10 shows the bounding IFBA case, which includes 8 WDRs and 128 IFBA pins. This is the lowest enrichment, maximum loading case and is bounding of all IFBA and WDR configurations. However, as shown in Table 4.7.11, the WABA loading is more limiting and was therefore selected for determination of the bias. The bias itself was selected from this table as the maximum reactivity difference case, at 17.5 GWD/MTU.

Based on the information presented in the table above entitled "Listing of the Range of Integral and Non-integral Absorber Configurations," the calculation results in Table 4.7.8 through 4.7.10 were performed to determine the reactivity effect of the integral and non-integral absorbers with the objective of determining a reactivity bias to be applied to all fuel assemblies. The analysis was performed in this manner to be conservative. This is conservative because not all fuel used integral or non-integral absorbers and the IFBA actually results in a negative reactivity effect for fuel that does not have sufficient burnup. Furthermore, this is conservative because as can be seen from the above table, only fuel regions 2 and 3 used WABA, and the WABA sensitivity calculations showed the greatest positive reactivity effect in the storage racks and set the reactivity bias higher than what would normally be applied for the WDR, IFBA, and IFBANWDR cases. Thus, the final keff includes fresh fuel in the calculation, and this reactivity bias is also being applied to fresh fuel.

Finally, additional clarification is provided to confirm that the reactivity bias calculations were bounding of the part length absorber case. Sensitivity calculations were done with part length IFBA and part length WABA rods. The guidance found in NUREG/CR-6760, "Study of the Effect of Integral Burnable Absorbers for PWR Burnup Credit," concludes that part length IFBA may bound the full length IFBA in the spent fuel storage rack. The study performed in NUREG/CR-6760 determines the spent fuel isotopic composition for fuel with and without IFBA. These compositions are then modeled with a 3D code like MCNP with a segmented axial burnup profile.

The sensitivity study performed for this response follows a similar methodology.

(([PROPRIETARY -

L-1 0-130 Page 41 of 43 NONPROPRIETARY VERSION OF THE RESPONSE WABA rods bound the cases that use part length IFBA and WABA rods.

In evaluating the studies performed in NUREG/CR-6760 for both full-length and part-length IFBA rods, it appears that the reason that part-length IFBA rods produced a larger (more positive) IFBA reactivity effect was that there was considerable residual IFBA remaining in the ends of the full-length IFBA rods, even at high assembly-average -burnups (i.e., the IFBA never completely burned out of the full-length rods because of the low fluxes at the ends of the rods). In fact, this residual effect was sufficiently large that the NUREG/CR-6760 study showed a negative IFBA reactivity effect at all burnups for full-length IFBA rods (in Table 10 of the NUREG). For this criticality analysis, the IFBA reactivity effect is calculated using a two-dimensional model in which there are no "end effects", since the assembly is essentially modeled as infinite in the axial direction. In this two-dimensional model, the IFBA completely burns out. With no residual IFBA present, the positive IFBA reactivity effect is maximized. Therefore, the two-dimensional model used in this analysis to determine the IFBA reactivity effect will produce bounding results.

L-10-130 Page 42 of 43 NONPROPRIETARY VERSION OF THE RESPONSE I fn Ir L-10-130 Page 43 of 43 NONPROPRIETARY VERSION OF THE RESPONSE I-1

34. Table 4.7.11 has a problem that is similar to that observed in Table 4.7.10.

The k. values presented from 0 to 15 GWd/MTU appear to include the worth of the WABA rods. In Table 4.7.11, it is clearly not appropriate to include the effects of the presence of the WABA rods in the bias calculations. Table 4.7.11 should have shown the impact of depletion with WABAs present, but the k. values presented should have been from restarts in rack geometry with WABAs removed.

Revise the analysis to correctly calculate the bias associated with depleting fuel with WABA present or justify not doing so. Secondly, justify not performing the calculations for the full range of initial enrichments and WABA loadings permitted.

Response

Information is provided in the response to RAI item 33, above.