Duke EEnergy-Catawba Nuclear Station Units 1 and 2 ODCM Offsite Dose Calculation Manual 2010

PhDuke aEnergy Catawba Nuclear Station Units 1 and 2 OFFSITE DOSE CALCULATION MANUAL (ODCM)

Prepared By: C. D. Ingram Approved By: L. E. Haynes General Office Radiation Protection Corporate RP Manager, Nuclear GO Reviewed By: B. N. Kimray Approved By: G. T. Hamrick CNS Radiation Protection CNS Station Manager REVISION NUMBER EFFECTIVE YEAR 52 2010 0

Catawba Nuclear Station January, 2010 Offsite Dose Calculation Manual (ODCM)

Revision 52 TABLE OF CONTENTS Executive Summary.

Executive Summary-I 1.0 Radwaste Systems

1. -1 1.0.1 Liquid Radwaste Processing 1-1 1.0.2 Gaseous Radwaste Processing 1-4 1.0.2.1 Gas Collection System 1-4 1.0.2.2 Containment and Auxiliary Building Ventilation 1-4 1.0.2.3 Secondary Systems 1-5 2.0 Release Rate Calculations 2-1 2.0.1 Liquid Release Rate Limit Calculations 2-1 2.0.1.1 RL/RN Discharge Release Rate Limit Calculation.

2-1

.2.0.1.2 WC Discharge Continuous Releases 2-2 2.0.2 Gaseous Release Rate Limit Calculations.

2-5 2.0.2.1 Unit Vent Discharge Release Rate Limit Calculation 2-5 3.0 Setpoint Calculations 3-1 3.0.1 Liquid Radiation Monitor Setpoint Calculations 3-1 3.0.1.1 WMT,RMT and AMT Setpoints (EMF 49 and EMF 57) 3-12 3.0.1.2 Turbine Building Sump to WC Setpoints (EMF 31) 3-3 3.0.2 Gaseous Radiation Monitor Setpoint Calculations 3-6 3.0.2.1 Containment Air Release and Addition (VQ) Setpoints (EMF 39, EMF 36) 3-8 3.0.2.2 Containment Purge (VP) and Incore Purge (IP) Setpoints (EMF 39, EMF 36).

3-9 3.0.2.3 Waste Gas Decay Tank (WGDT) Setpoints (EMF 50, EMF 36) 3-10 4.0 Effluent Dose Models.

4-1 4.0.1 Liquid Effluent Dose Model for the Maximum Exposed Individual 4-1 4.0.2 Gaseous Effluent Dose Model for the Maximum Exposed Individual.

4-7 4.0.3 Direct Radiation 4-18 4.0.4 Effluent Apportionment 4-18 5.0 FuelCycle Calculations.

5-1 5.0.1 Milling 5-1 5.0.2 Conversion 5-1 5.0.3 Enrichment 5-1 5.0.4 Fuel Fabrication 5-1 5.0.5 Nuclear Power Production 5-2 5.0.6 Fuel Reprocessing 5-2 5.0.7 40CFR190 Total Dose Determination 5-2 6.0 Environmental Locations 6-1 6.0.1 Site Description and Sample Locations 6-1 6.0.2 Land Use Census Data 6-1 6.0.3 Catawba Meteorology: Relative Air Concentrations and Deposition 6-8 6.0.3.1 XOQDOQ Methodology and Assumptions 6-8 6.0.3.2 Meteorological Data 6-8 6.0.3.3 Annual XOQDOQ Comparison to the ODCM 6-9 7.0 Licensee Initiated Changes 7-1

Catawba Nuclear Station January, 2010 Offsite Dose Calculation Manual (ODCM)

Revision 52 Appendices Appendix A: Dose Factors for Exposure to a Semi-Infinite Cloud of Noble Gas.

A-1 Appendix B: Pi Dose Factors for use in the Gaseous Release Rate Limit Calculations B-1 Appendix C: Ai Adult Dose Factors for use in the Liquid Dose Calculations.

C-1 Appendix D: Ai Teen Dose Factors for use in the Liquid Dose Calculations D-1 Appendix E: Ai Child Dose Factors for use in the Liquid Dose Calculations E-1 Appendix F: Ai Infant Dose Factors for use in the Liquid Dose Calculations F-1 Appendix G: Ri Adult Dose Factors for use in the Gaseous Dose Calculations G-1 Appendix H: Ri Teen Dose Factors for use in the Gaseous Dose Calculations H-1 Appendix I: Ri Child Dose Factors for use in the Gaseous Dose Calculations I-1 Appendix J: Ri Infant Dose Factors for use in the Gaseous Dose Calculations J-1 LIST OF FIGURES 1.0-1 Liquid Radwaste System.

1-3 1.0-2 Gaseous Radwaste System (2 pages) 1..

-6 2.0-1. Liquid Radwaste Discharge Locations 2-3 2.0-2 Liquid Radwaste Discharge to Lake Wylie 2-4 2.0-3 Unit Vent Release Points.

2-8 6.0-1 Sampling Locations Map (Site Boundary).

6-5 6.0-2 Sampling Locations Map (Ten Mile Radius) 6-6 6.0-3 Land Use Census Map 6-7 LIST OF TABLES 3.0-1 EMF 49 and EMF 31 Cs-137 Equivalence Factors 3-4

.3.0-2 EMF 57 Cs-137 Equivalence Factors.

3-5 3.0-3 Xe-133 Equivalents.

3-I1 6.0-1 Sampling Locations 6-2 6.0-2 TLD Sites 6-3 6.0-3 Land Use Census Results.

6-4 6.0-4 CNS Atmospheric Stability Frequency (1988 - 1992) 6-9 6.0-5 CNS Frequency of Wind Direction and Speed (1988 - 1992) 6-9 6.0-6 CNS Limiting X/Q and D/Q Values (1988 - 1992) 6-10 6.0-7 CNS Delta-T Ranges per Vertical Separation Distances 6-10 6.0-8 Catawba X/Q Average Values (1988-1992) 6-11 6.0-9 Catawba D/Q Average Values (1988-1992) 6-12 ii

Catawba Nuclear Station January, 2010 Offsite Dose Calculation Manual (ODCM)

Revision 52 EXECUTIVE

SUMMARY

The Catawba Nuclear Station (CNS) Offsite Dose Calculation Manual (ODCM) provides the methodology and parameters to be used in the calculation of offsite doses due to normal operation radioactive liquid and gaseous effluents to assure compliance with the dose limitations of the Selected Licensee Commitments (SLCs, UFSAR Chapter 16) and Technical Specifications (TSs). These dose limitations assure that:

(1) the concentration of radioactive liquid effluents released from the site to the unrestricted area will be limited to 10 times the effluent concentration (EC) levels of IOCFR20, Appendix B, Table 2, and 2.OE-04 pCi/ml for dissolved and entrained noble gases (TS 5.5.5(a)(2), SLC 16.11-1);

(2) the exposures to any individual member of the public from radioactive liquid effluents will not result in doses greater than the ALARA design objectives of IOCFR50, Appendix I or the 10CFR20 limits (TS 5.5.5(a)(4), SLC 16.11-3);

(3) the dose rate at any time at the site boundary from radioactive gaseous effluents will be limited to: for noble gases; less than or equal to 500 mrem/yr to the whole body, and less than or equal to 3000 mrem/yr to the skin; and for iodine-131 and iodine-133, for tritium, and for all radioactive materials in particulate form with half-lives greater than 8 days; less than or equal to 1500 mrem/yr to any organ (TS 5.5.5(a)(7), SLC 16.11-6);

(4) the exposure to any individual member of the public from radioactive gaseous effluents will not result in doses greater than the ALARA design objectives of 10CFR50, Appendix I or the 10CFR20 limits (TS 5.5.5(a) (8 and 9), SLCs 16.11-8 and 16.11-9); and r

(5) the dose to any individual member of the public from the nuclear fuel cycle will not exceed the limits of 40CFR190 (TS 5.5.5(a)(10), SLC 16.11-12).

The methodology and parameters used to assure compliance with the dose limitations described above shall be used to prepare the radioactive liquid and gaseous effluent reports required.

by the SLCs and Technical Specifications. Dose calculations that.

demonstrate compliance with 40CFR190 will be considered to demonstrate Executive Summary - Page 1

Catawba Nuclear Station January, 2010 Offsite Dose Calculation Manual (ODCM)

Revision 52 compliance with the 10CFR20 0.1-rem annual dose limit. The ODCM also provides the methodology and parameters to be used in the calculation of radioactive liquid and gaseous effluent monitoring instrumentation alarm/trip setpoints to assure compliance with the concentration and dose rate limitations of the SLCs and 'Technical Specifications.

Normally RETDAS, a computer code that implements NUREG-0133 methodology, is used for the calculation of offsite doses, but the ODCM also provides a method for the calculation of offsite doses when RETDAS is not available.

The ODCM has been prepared as generically as possible in order to minimize the need for revisions. However, some changes to the ODCM such as land use census data are expected on an annual basis. Any changes to the methodology and parameters to be used in this ODCM shall be reviewed by knowledgeable individual(s), and approved by the Station Manager and the General Office Radiation Protection Manager prior to implementation. Changes to the ODCM. shall be submitted to the Nuclear Regulatory Commission in accordance with the SLCs and Technical Specifications.

The ODCM does not replace any station implementing procedures.

Programmatic controls for radioactive effluents and radiological environmental monitoring are contained in the Administrative Controls chapter of the Technical Specifications.

Procedural details for radioactive effluents and radiological environmental monitoring consisting of licensee commitments, applicability, remedial actions, surveillance requirements, and the bases for these requirements are contained in Section 16.11 of the SLCs.

Executive Summary - Page 2

Catawba Nuclear Station January, 2010 Offsite Dose Calculation Manual (ODCM)

Revision 52 1.0 RADWASTE SYSTEMS 1.0.1 LIQUID RADWASTE PROCESSING The liquid radwaste system at Catawba Nuclear Station is used to collect and treat liquid chemical and radiochemical byproducts of unit operation. The system produces effluents that can be reused in the plant or discharged in small, dilute quantities to the environment. The means of treatment vary with waste type and desired product in the various systems:

(A) Filtration - Waste sources may be filtered during processing.

(B) Adsorption - Adsorption of halides and organic chemicals by activated charcoal (carbon filter) may be used as needed in treating waste streams in the Liquid Radwaste System (WL). The carbon filter' is-designed to remove organophosphates and free chlorine. Activated charcoal need not be used when these chemicals are not present (e.g., phosphate detergents are not used at the station). Ion exchange resin or other media may be used in the carbon filter vessel as desired.

(C) Ion Exchange - Ion exchange is used to remove radioactive ions from solution, as in the case of the Floor and Equipment drain waste in WL, after removal of organics by carbon filtration (adsorption).

Ion exchange is also used in removing both radioactive and non-radioactive ions from evaporator distillates in order to purify the distillates for reuse as makeup water. Distillate from the Boron Recycle Evaporator in the Boron Recycle System (NB) can be treated by this method, as well as WL waste, and reactor bleed.

(D) Gas Stripping - Removal of gaseous radioactive fission products is accomplished in recycled water by the NB Evaporator.

(E) Distillation - Production of pure water from reactor coolant by boiling it away from the contaminated solution which it was originally contained is accomplished by the NB evaporator. Proper control of the process will yield water that can be reused for makeup. Polishing of this product can be achieved by ion exchange as discussed above.

(F) Concentration - In the NB Evaporator dissolved chemicals are concentrated in the lower shell as water is boiled away. The WL Evaporator is no longer utilized due to more cost effective process options for floor and equipment drains, e.g., ion exchange. In the NB Evaporator the dilute boron is normally concentrated to 4% so that it may be reused for makeup to the reactor coolant system.

Section 1 - Page I

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 Figure 1.0-1 is a schematic representation of the liquid radwaste system at Catawba.

Section 1 - Page 2

(

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

Figure 1.0-1 Catawba Nuclear Station Liquid Radwaste System January, 2010 Revision 52 Section 1 - Page 3

Catawba Nuclear Station January, 2010 Offsite Dose Calculation Manual (ODCM)

Revision 52 1.0.2 GASEOUS RADWASTE PROCESSING The Gaseous Waste System (WG) for Catawba is designed with the capability of processing the fission product gases from contaminated reactor coolant fluids resulting from operation. The design basis for the WG shown schematically in Figure 1.0-2 is the retention, through the plant lifetime, of all the gaseous fission products to be discharged from the reactor coolant system to the Chemical and Volume Control System (NV) and other plant systems to eliminate the need for intentional discharge of radioactive gases from the waste gas holdup tanks. Actual system operation is aimed at maximizing storage time for decay prior to infrequent releases. Unavoidable sources of low level radioactive gaseous discharge to the environment will be from periodic purging operations of the containment, and.through the secondary system air ejector.

With respect to the former, the potential contamination is expected to arise from non-recyclable reactor coolant leakage. With respect to the air ejector, the potential source of contamination will be from leakage of the reactor coolant to the secondary system through defects in steam generator tubes. The gaseous waste disposal system includes two waste gas compressors, two catalytic hydrogen recombiners, six gas decay storage tanks for use during normal power generation, and two gas-decay storage tanks for use during shutdown and startup operations, and for pressure relief.

1.0.2.1 GAS COLLECTION SYSTEM The gas collection system combines the waste hydrogen and fission gases from the volume control tanks, the boron recycle and liquid waste gas stripper evaporators, and other sources produced during normal operation or the gas collected during the shutdown degasification (high percentage of hydrogen), and cycles it through the catalytjc recombiners to convert hydrogen to water.

After -the water vapor is removed, the resulting gas stream is transferred from -the recombiner into the waste gas decay tanks (WGDTs), where the accumulated activity may be contained in' six approximately equal parts. From the decay tanks, the gas flows back to the compressor suction to complete the circuit.

1.0.2.2 CONTAINMENT AND AUXILIARY BUILDING VENTILATION 9

Non-recyclable reactor coolant leakage occurring either inside the containment or inside the auxiliary building will generate gaseous activity. Gases resulting from leakage inside the containment will be contained until the containment air is released through either the Containment Air Release and Addition System (VQ) or the Containment Purge System (VP). The containment atmosphere will be discharged through charcoal adsorbers and HEPA filters to reduce releases to the environment.

Gases resulting from leakage inside the auxiliary building are released, without further decay, to the atmosphere. The ventilation exhaust from potentially contaminated areas in the auxiliary building is passed through charcoal adsorbers and HEPA filters to reduce releases to the atmosphere upon a radiation monitor alarm.

Section 1 -Page 4

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 1.0.2.3 SECONDARY SYSTEMS Normally, condensate flow and steam generator blowdown will go parallel through 4 of the 5 condensate polishing demineralizers to remove activity and harmful ions from the water. Non-condensable gases will be taken from the secondary system by the condenser steam air ejector, and are passed through a radiation monitor to the unit vent.

Figure 1.0-2 is a schematic representation of the gaseous radwaste system at Catawba.

Section 1 - Page 5

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 01 Figure 1.0-2 Catawba Nuclear Station Gaseous Radwaste System Page 1 of 2 SUPPLY FANS AUXILIARY BUILDING SYSTEM ISHARED)

LEGEND, P

PREFILTER A

HIGH-EFFICIENCY PARTICULATE FILTER C

CHARCOAL ABSORBER

  • FUEL HANDLING AREA IS NDRMALLY UNFILTERED. UPON A RADIATION ALARM BY EMF-42.

THE EXHAUST WILL BE DIVERTED TO THE FILTER MOSE.

-POTENTIALLY CONTAMINATED AREAS OF THE AUXILIARY BUILDING ARE NORMALLY UNFILTERED. UPON A RADIATION ALARM BY ERF-4 1. THE EXHAUST WILL BE DIVERTED TO THE FILTERED MODE.

Section 1 - Page 6

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 Figure 1.0-2 Catawba Nuclear Station Gaseous Radwaste System Page 2 of 2 i

AUXILIARY MONITOR TANK. BUILDING 1

EMF 58 Section 1 - Page 7

Catawba Nuclear Station January, 2010 Offsite Dose Calculation Manual (ODCM)

Revision 52 2.0 RELEASE RATE CALCULATIONS 2.0.1 LIQUID RELEASE RATE LIMIT CALCULATIONS There are two liquid radwaste discharge points to the environment at Catawba; (1) the Low Pressure Service Water System (RL) and Nuclear Service Water System (RN) discharge point to Lake Wylie, and (2) the Conventional Waste Water Treatment System (WC) discharge point to Lake Wylie (See Figure 2.0-1).

2.0.1.1 RL/RN DISCHARGE RELEASE RATE LIMIT CALCULATION I

Liquid releases to Lake Wylie through the RL/RN pathway normally contain the radioactive releases from the site including effluents from the waste monitor tanks, recycle monitor tanks, and auxiliary monitor tanks. The RL/RN discharge point can also contain turbine building sump (TBS) releases, however TBS effluent is normally released through the WC discharge point. There are three RL pumps with a minimum flow rate of 19,000 gpm each, and four RN pumps with a minimum flow rate of 9,000 gpm each which provide the required dilution water needed for a release. Each release path has a radiation monitor (EMF) that is used to monitor the liquid effluent (See Figure 2.0-2).

To comply with Technical Specifications and Selected Licensee Commitments, and to assure that the concentration of radioactive liquid effluents released from the site to the unrestricted area is limited to 10 times the effluent concentrations (ECs) of 10CFR20, Appendix B, Table 2, Column 2, and 2.OE-04 pCi/ml for dissolved and entrained noble gases, the following release rate limit calculation shall be performed for liquid releases to Lake Wylie via the RL/RN discharge point:

f* F - (DF-1) Condition: DF> 1.0 Equation 2.1 where:

f the undiluted effluent flow, in gpm.

F the dilution flow available depending on the number of RL/RN pumps in service, in gpm for batch releases, e.g., Waste Monitor Tank.

DF required dilution factor to be applied to the undiluted effluent flow, unitless.

DF=c x Ci Equation 2.2 i (0 x EC*)

Section 2 - Page 1

Catawba Nuclear Station January, 2010 Offsite Dose Calculation Manual (ODCM)

Revision 52 Note:

If DF -< 1.0 then no dilution is required and the release rate is unrestricted.

If DF > 1.0 then dilution flow is required and the release rate is calculated using Equation 2.1. Equation 2.1 is used only when DF > 1.0.

a

= the most restrictive recirculation factor at equilibrium, (dimensionless). The recirculation factor accounts for the fraction of discharged water reused by the station. For Catawba the recirculation factor equals 1.0 since discharged liquid effluent is not reused by the station.

Ci the concentration of radionuclide, 'i', in the undiluted liquid effluent, in jtCi/ml.

ECi the concentration of radionuclide, 'i', from 10CFR20, Appendix B, Table 2, Column 2, in ptCi/ml. Note: if radionuclide, 'i', is a dissolved noble gas, then ECi

= 2.OOE-05 jiCi/ml.

2.0.1.2 WC DISCHARGE CONTINUOUS RELEASES Liquid releases\\ to Lake Wylie via the WC discharge point normally contain little measurable activity above background.

Although designed for continuous discharge, inputs to WC, primarily from the Unit 1 and Unit 2 turbine building sumps, are normally held up in one of three WC Ponds, then released as a batch. There is a composite sampler at the discharge to the lake. An EMF monitors the TBS/Condenser Drain output (See Figure 2.0-2). It is assumed that no activity is present in the TBS effluent until indicated by radiation monitoring measurements. If radioactivity is detected above the monitor's alarm setpoint, analternate discharge route may be used. A control room alarm indicates this radioactivity. At this time the discharge may be routed to WL for processing rather than through WC. Liquid effluent releases through WC typically account for less than 1% of tritium releases from Catawba.

Section 2 - Page 2

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

Figure 2.0-1 Liquid Radwaste Discharge Locations

'York Co

/

SNSW' K'

o D i:schrg

iJ'/* *,

Structure we f

1 v4 JRIR DAchrg January, 2010 Revision 52

.1<:)!

  • \\

/1

/1 Section 2 - Page 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

Figure 2.0-2 Liquid Radwaste Discharge to Lake Wylie January, 2010 Revision 52 Lake Wylie Lake Wylie 2

Q Section 2 - Page 4

Catawba Nuclear Station January, 2010 Offsite Dose Calculation Manual (ODCM)

Revision 52 2.0.2 GASEOUS RELEASE RATE LIMIT CALCULATIONS The two unit vents are the primary gaseous radioactive release points at Catawba. The.unit vents are the release points for waste gas decay tanks, containment building purges, auxiliary building ventilation, and the condenser air ejector (see Figure 2.0-3). Each unit vent has multi-range radiation monitors and flow rate measuring instrumentation..

There is one other separate gaseous effluent release point at Catawba, the Auxiliary Monitor Tank Building (AMTB), that is normally considered non-radioactive; that is, it is possible but unlikely that the effluent will contain measurable activity above background.

However, the potential for release of radioactive effluents remains with certain job evolutions that may take place in the AMTB. The process areas of the AMTB ventilation pass through particulate and charcoal filters.

The AMTB release point has an EMF, effluent sampler, and flow totalizer (see Figure 1.0-2).

2.0.2.1 UNIT VENT DISCHARGE RELEASE RATE LIMIT CALCULATION In order to comply with Technical Specifications and SLCs and to assure that the dose rate, at any time, at or beyond the site boundary due to radioactive materials released in gaseous effluents from the site is limited to: _< 500 mrem/yr to the total body, and < 3000 mrem/yr to the skin for the noble gases,- and is limited to _< 1500 mrem/yr to any organ for radioiodine and for radioactive materials in particulate form, and radionuclides other than noble gases with half lives greater than 8 days, the following release rate and radiation monitor setpoint calculations shall be performed for releases from the waste gas decay tanks and the containment building. The release rate calculations when solved for the flow rate,'f', are the release rates for noble gases and for radioiodines, particulates and other radionuclides with half-lives greater than 8 days.

The most conservative release rate calculated shall control the flow rate. The following equations are based on the site dose rate limits. When applied to the individual release points the site dose rate values are apportioned 49% to each unit vent and 2% to the AMTB vent assuring that simultaneous releases from all release points do not exceed the controlling release rate for a single point.

a. Noble Gases Total Body:

Y K, x x Q,j

< 500 mrem/yr Equation 2.3 SQ Skin:

I((Li+ 1.lM) x x Qi j < 3000 mrem/yr Equation 2.4 Section 2 - Page 5

Catawba Nuclear Station January, 2010 Offsite Dose Calculation Manual (ODCM)

Revision 52

b. Radioiodines, Particulates, and.Others Inhalation, Ingestion and Ground Organ Pathways:

Z X(Popi x W x Qi x E) < 1500 mrem/yr p

i To include both the food and ground organ dose and the inhalation organ dose the equation can be expanded to:

E E({(P pi f°°d/g x WD/Q + (POopi )nhal X WX/Q} x Q x E) < 1500 mrem/yr p

i Equation 2.5 where:

Ki the total body dose factor due to gamma emissions for each identified noble gas radionuclide, 'i', in mrem/yr per ýtCi/m 3 (See Appendix A).

Li

= the skin dose factor due to beta emissions for each identified noble gas radionuclide, 'i', in mrem/yr per pLCi/m 3 (See Appendix A).

Mi

=the air dose factor due to gamma emissions for each identified noble gas radionuclide, 'i', in mrad/yr per jiCi/m3 (See Appendix A).

Popi the dose parameter for radionuclides other than noble gases for the inhalation pathway, in mrem/yr per pCi/mr3 and for the food and ground plane pathways in (M 2 x (mrem/yr per VtCi/sec)) for organ, 'o', and radionuclide, 'i', (See Appendix B for the pathway specific dose commitment factors). Note: NUREG-1301, page 75, specifies use of the Child age group, Inhalation pathway, for the Popi values.

X/Q the highest calculated annual average dispersion parameter for any area at or beyond the site boundary in sec/mr3. For Catawba this value is 3.51 OE-5 sec/m3.

The location is the NNE sector at 0.5 mile. As discussed in Catawba UFSAR Section 2.1.1.3, the boundary for establishing gaseous effluent release limits is the exclusion area boundary (EAB). The EAB is defined as a 2500-ft. (-0.5 mile) radius from the station center.

W the highest calculated annual average dispersion or deposition parameter for estimating the maximum dose rate to an individual from the total inhalation, food, and ground plane pathways:

Wz/Q

= 3.51 OE-5 sec/m 3, for the inhalation pathway and the airborne H-3 food pathway. The location is the NNE sector at 0.5 mile.

Section 2-Page 6

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 WD/Q

= 1.078E-7 m-2, for the food and ground plane pathways. The location is the NNE sector at 0.5 mile.

Ei the filter removal factor for radionuclide, 'i', e.g., for 99% removal E1 = 0.01.

For VQ, VP and AMTB releases E- 0.1 for iodine, 0.01 for particulates. There is no filtration for WGDT releases.

Q

= the release rate of radionuclide, 'i", in gaseous effluentfrom all release points at the site, in jtCi/sec.

Qi'= kiC'f + k2 = 472 x Cf Equation 2.6 where:

C, = the concentration of radionuclide, 'i', in undiluted gaseous effluent, in ýtCi/ml.

f

= the undiluted effluent flow, in ft3/min.

k,

= conversion factor, 2.83E+04 cc/ft3.

k2 conversion factor, 60 sec/min.

Substituting the expression for Qj in Equation 2.6 into Equations 2.3, 2.4, and 2.5, and solving for the flow rate, 'f, in each equation gives:

Noble Gases - Total Body Maximum Release Rate:

fb<

500 472 x xIQ x

-(Ki x C,)

i Noble Gases - Skin Maximum Release Rate:

3000

]sk <

472 x x/Q x II(L + 1.1M) x c,]

i Radioiodines, Particulates, and Others - Organ Maximum Release Rate:

1500 f.r 472 x E

-({(XPop

)foodWgr X WDIQ + (p 0 i )inhal X WxIQ} X Ei x Ci) p I

fib, fik, and for, are calculated for each batch prior to release. The most limiting gaseous release rate is used to assure that no instantaneous dose rate limit is exceeded.

Section 2 - Page 7

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

Figure 2.0-3 Unit Vent Release Points January, 2010 Revision 52 UNIT VENT Condensote Steom A-i Ejectors Section 2 - Page 8

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 Derivations of Iodine, Particulate, and H-3 Dose Commitment, Factors (eopi)

Inhalation Pathway - Child Age Group Pi

= K'(BR )(DFA oi)

Formula: from NUREG-0133, page 25.

Where:

Popi Dose commitment factor for child age group, organ o, nuclide i, for the inhalation pathway (mrem/yr per pCi/m3). (See Appendix B for the pathway specific dose commitment factors).

K' Units conversion factor pCi/tCi (106).

BR Breathing rate for the child age group (m3/yr, from Regulatory Guide 1.109):

Child - 3700

(

DFAoi Organ inhalation dose conversion factor for child age group, organ o, nuclide i, (mrem/pCi), from Table E-9 of Regulatory Guide 1.109.

Section 2 - Page 9

Catawba Nuclear Station January, 2010 Offsite Dose Calculation Manual (ODCM)

Revision'52 3.0 SETPOINT CALCULATIONS 3.0.1 LIQUID RADIATION MONITOR SETPOINT CALCULATIONS Once the liquid release rate parameters have been established radiation monitor setpoints shall be calculated to assure that the concentration of radioactive liquid effluents released from the site to the unrestricted area is limited to ten times the effluent concentrations (ECs) of 10CFR20, Appendix B, Table 2, Column 2, and 2.OE-04 ltCi/ml for dissolved and entrained noble gases. By substituting the dilution factor (DF) from Equation 2.2 into Equation 2.1, solving for the undiluted liquid effluent concentration, Ci, and-accounting for the monitor background reading, the liquid radiation monitor setpoint can be readily obtained by multiplying Ci by the radiation monitor correlation factor, CFi, as follows:

Ci < (F + f) x(10 x EC1)

Equation 3.1 SP <

" (C, x CF,) + bkg Equation 3.2 where:

Ci

= the maximum allowable concentration of radionuclide, 'i', in the undiluted liquid effluent, in jiCi/ml.

SP = radiation monitor setpoint, in cpm.

CFj = radiation monitor correlation factor for radionuclide, 'i', in cpm/ViCi/ml.

bkg = background reading for the radiation monitor, in cpm.

All other parameters were previously defined.

Using conservative or "worst-case" parameters in Equation 3.1 and Equation 3.2 can provide a liquid radiation monitor setpoint that does not need to be revised for every release if activity is low enough to allow for this type of operation. Prior to the release to assure that the standard setpoints will not be exceeded for the batch release, the "Expected cpm" is calculated.

In general, liquid radiation monitors are calibrated to Cs-137, and their "Expected cpm" is calculated as follows:

Section 3 - Page 1

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January; 2010 Revision 52 CO - 137 =Z ~(C x Eq1)

Expected cpm =(Ccs-137 x CFcs6137) + bkg where:

CCcs-17

= Cs-137 equivalent concentration, in pCi/ml.

Equation 3.3 Eqj

= Cs-137 equivalence factor for each isotope, excluding tritium, to that of Cs-137 due to different gamma energies and abundance. This factor includes a 4-hour decay time due to the average time between sample and release. (See Table 3.0-1 and Table 3.0-2).

All other parameters were previously defined.

3.0.1.1 WMT. RMT, AND AMT SETPOINTS (EMF 49 AND EMF 57)

As shown on Figure 2.0-2, EMF 49 is the controlling radiation monitor for Waste Monitor Tank (WMT) and Recycle Monitor Tank (RMT) releases, and EMLF 57 is the controlling radiation monitor for Auxiliary Monitor Tank (AMT) releases. As discussed previously, standard setpoints are calculated for EMF 40 and EMF 57 based on "worst-case" parameters using Equation 3.1 and Equation 3.2 as follows:

C* < (F + f) x (10 x ECJ) c-xf C < (25,500 + 100) x (7 x 9.OE-07) < 1.613E-03 pCi/ml 1.0 x 100 SP < Z (C, x CF,) + bkg Trip2 1.613E-03 x 8.OOE+07 1.29E+05 cpm A Trip 2 setpoint of 1.20E+05 cpm is used for conservatism.

Trip 1 = Trip 2 x 0.7 = 8.40E+04 cpm Where:

25,500

= RL/RN minimum dilution flow available (gpm).

100

= Flow from WMT, RMT, or AMT (gpm).

Section 3 - Page 2

Catawba Nuclear Station January, 2010 Offsite Dose Calculation Manual (ODCM)

/ Revision 52 7

=

10CFR20, Appendix B, Table 2, Column 2, EC multiplier used for instantaneous liquid release rate concentration limit. Technical Specifications allow a multiplier of 10. A value of 7 is used for added conservatism.

9.OE-07 EC for Cs-134 which is the lowest effluent concentration value for any detectable radionuclide not known to be absent from the liquid effluent 1.0 The recirculation value for Catawba (unitless).

8.OOE+07 = The most restrictive radiation monitor correlation value between EMF 49 (3.45E+08 cpm/ýtCi/ml) and EMF 57,(8.OOE+07 cpm/pCi/ml).

Prior to the release to assure that the standard Trip 1 and Trip 2 setpoints are not exceeded for the batch release, the "Expected cpm" is calculated based on actual tank activity as previously shown in Equation 3.3. For the "Expected cpm" calculation the applicable EMF 49 or EMF 57 correlation value is used rather than the most restrictive value.

3.0.1.2 TURBINE BUILDING SUMP TO WC SETPOINTS (EMF 31)

As shown on Figure 2.0-2, EMF 31 is the controlling radiation monitor for releases from the Turbine Building Sump (TBS) to the Conventional Waste Water Treatment System (WC).

EMF 31 setpoints are used to terminate the release to WC if there is any detectable activity in the effluent. The setpoints are calculated using Equation 3.2 as follows:

Trip 2= 1.OE-06 x 3.45E+08 + bkg Trip 1 =Trip2 x 0.7 where:

1.OE-06

= Minimum detectable Cs-137 equivalent concentration, in RCi/ml.

3.45E+08

= EMF 31 Cs-137 correlation factor, in cpm/tCi/ml.

bkg

= Background reading from EMF 31.

To assure that the standard Trip 1 and Trip 2 setpoints are not exceeded for TBS releases, the "Expected cpm" is calculated based on actual TBS sample activity as previously shown in Equation 3.3.

Section 3 - Page 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 Table 3.0-1 EMF 49 and EMF 31 Cs-137 Equivalence Factors Isotope*:

Equivilencel Isotopes? 1Equivalence Isotope Equivalencer

Factor,
Factor,

']Factor Be-7 0.1282 Mo-99 0.3135 La-141 0.0132 F-18 0.5238 Tc-99m 0.5788 La-142 0.2785 Na-24 1.3013 Tc-101 0.00 Ce-141 0.4966 CI-38 0.0068 Ru-103 1.1798 Ce-143 0.7066 K-40 0.0913 Ru-105 0.8673 Ce-144 0.1321 Cr-51 0.1207' Ru-106

  • 0.4097 1-130 3.1610 Mn-54 1.0871 Ag-108m 3.2676 1-131 1.2074 Mn-56 0.4826 Ag-I 10m 3.5043 1-132 1.0137 Fe-59 0.9915 Cd-ll5 0.4739 1-133 1.0971 Co-57 0.8892 Cd-115m 0.0228 1-134 0.1396 Co-58 1.4883 In-115m 0.3048 1-135 0.8432 Co-60 1.8564 Sb-122 0.8691 Ar-41 0.1987 Cu-64 0.3577 Sb-124 2.0195 Kr-85 0.0054 Ni-65 0.1389 Sb-125 1.0467 Kr-85m 0.5240 Zn-65 0.5278 Sb-126 5.0018 Kr-87 0.1020 Zn-69m 0.9788 Sn-113 0.8413 Kr-88 0.4607 Se-75 1.9710 Sn-123 0.0062 Kr-89 0.00 Br-80m 0.0821 Sn-126 0.1747 Xe-131m

,0.0211 Br-82 3.3664 Te-125m 0.0023 Xe-133 0.0520 Br-83 0.0054 Te-127 0.0116 Xe-133m 0.1176 Br-84 0.0056 Te-127m 0.0005 Xe-135 0.8334 Br-85 0.00 Te-129 0.0122 Xe-135m 0.00 Rb-86 0.0873 Te-129m 0.0526 Xe-137 0.00 Rb-88 0.00 Te-131 0.0016 Xe-138 0.00 Rb-89 0.00 Te-131m 1.9281 Nd-147 0.3706 Sr-89 0.0002 Te-132 1.0302 Hf-181 1.7053 Sr-91 0.6398 Te-134 0.0402 W-187 0.8499 Sr-92 0.3415 Cs-134 2.5843 T1-208 0.00 Y-91 0.0028 Cs-136 3.1799 Bi-212 0.0140 Y-91m 0.0403 Cs-137 1.00 Bi-214 0.0003-Y-92 0.1281 Cs-138 0.0110 Pb-212

.0.4507 Y-93 0.1009 Ba-133 1.2331 Pb-214 0.0018 Zr-95 1.1163 Ba-139 0.0255 Ra-226 0.0386 Zr-97 1.1163 Ba-140 0.5022 Ac-228 0.8370 Nb-95 1.1114 Ba-141 0.0002 Th-228 0.0090 Nb-95m 0.2929 Ba-142 0.00 Np-239 0.8989 Nb-97 0.1164 La-140 2.0586 Section 3 - Page 4

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 Table 3.0-2 EMF 57 Cs-137 Equivalence Factors Isoto*p"e Equivalence E**I 6

!sotopef EEqquivaalencIs lalence Factor

!Factor.,

Factor Be-7 0.1462 Mo-99 0.2668 La-141 0.0155 F-18 0.5788 Tc-99m 0.00 La-142 0.2942 Na-24 0.8519 Tc-101 0.00 Ce-141 0.00 C1-38 0.0090 Ru-103 1.3368 Ce-143 0.7826 K-40 0.1094 Ru-105 0.8783 Ce-144 0.0273 Cr-51 0.1438 Ru-106 0.4429 1-130 3.3095 Mn-54 1.0617 Ag-108m 3.4473 1-131 1.4051 Mn-56 0.4992-Ag-110m 3.5179 1-132 1.0259 Fe-59 1.0556 Cd-115 0.5201 1-133 1.1857 Co-57 0.0022 Cd-115m 0.0235 1-134 0.1388 Co-58 1.4735 In-I15m 0.3631 1-135 0.9374 Co-60 2.0495 Sb-122 0.9218 Ar-41 0.2229 Cu-64 0.3954 Sb-124 2.1617 Kr-85 0.0059 Ni-65 0.1591 Sb-125 1.1308 Kr-85m 0.4280 Zn-65 0.5584 Sb-126 5.1762 Kr-87 0.1213 Zn-69m 1.1391 Sn-113 0.9971 Kr-88 0.5278 Se-75 1.3092 Sn-123 0.0066 Kr-89 0.00 Br-80m 0.0860 Sn-126 0.00 Xe-131m 0.0167 Br-82 3.4691 Te-125m 0.00 Xe-133 0.0006 Br-83 0.0059 Te-127 0.0134 Xe-133m 0.1172 Br-84 0.0053 Te-127m 0.0001 Xe-135 0.8564 Br-85 0.00 Te-129 0.0138 Xe-135m 0.00 Rb-86 0.0894 Te-129m -

0.0507 Xe-137 0.00 Rb-88 0.00 Te-131 0.0008 Xe-138 0.00 Rb-89 0.00 Te-131m 1.8463 Nd-147 0.2619 Sr-89 0.0002 Te-132 0.9766 Hf-181 1.4209 Sr-91 0.6460 Te-134 0.0408 W-187 0.8027 Sr-92 0.3900 Cs-134 2.5804 TI-208 0.00 Y-91 0.0031 Cs-136 3.1916

,Bi-212 0.0144 Y-91m 0.0439 Cs-137 1.00 Bi-214 0.0003 Y-92 0.1334 Cs-138 0.0120 Pb-212 0.4497 Y-93 0.1091 Ba-133 1.3648 Pb-214 0.0020 Zr-95 1.0909 Ba-139 0.0203 Ra-226 0.0320 Zr-97 1.1210 Ba-140 0.5307 Ac-228 0.8261 Nb-95,,

1.0821 Ba-141 0.0002 Th-228 0.0038 Nb-95m 0.2919 Ba-142 0.00 Np-239 0.3996 Nb-97 0.1164 La-140 2.3237 Section 3 - Page 5

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 0

3.0.2 GASEOUS RADIATION MONITOR SETPOINT CALCULATIONS In general, gaseous radiation monitors (EMFs) are calibrated to Xe-133, and for continuous release points, e.g., the two unit vents, are preset at a maximum value based on the 500 mrem/year total body gaseous release rate limit according to the following methodology. Note: when applied to the individual release points the 500 mrem/year site dose rate value is apportioned 49% to each unit vent and 2% to the Auxiliary Monitor Tank Building.

Kxe-133 X X/Q X Qxe-133 < 500 mrem/yr Solve for QXe-133:

500 Qxe -133 500 gxe-133 X z/Q Equation 3.4 From Equation 2.6:

QXe-133

= 472 x CXe-133 X f Equation 3.5 Substitute Equation 3.5 into Equation 3.4:

500 472 x CXe-133 X f Kxe-133 X x/Q Solve for Cxe-133:

CXe-133 500 472 x f x gce-133 X X/Q SP = (CXe-133 x CF) + bkg Equation 3.6 where:

Kxe-133 2.94E+02, the total body dose factor due to gamma emissions for Xe-133, in mrem/year per PtCi/m 3 (See Appendix A).

X/Q

=

the highest calculated annual average dispersion parameter for any area at or beyond the site boundary in sec/m 3. For Catawba this value is 3.5 1OE-5 sec/m 3. The location is the NNE sector at 0.5 mile.

QXe-133

= Xe-133 equivalent release rate limit for the noble gas total body dose pathway, in jtCi/sec.

Section 3 - Page 6

Catawba Nuclear Station January, 2010 Offsite Dose Calculation Manual (ODCM)

Revision 52 472

= conversion factor, (cc/ft3)/(sec/min).

CXe-133

= the maximum allowable Xe-133 equivalent concentration in the gaseous effluent, in p[Ci/cc.

f

= the gaseous effluent flow from the tank, building, or vent, in ft3/min.

SP

= radiation monitor setpoint, in cpm.

CF

= the Xe-133 equivalent monitor correlation factor, in cpm/ýtCi/cc.

bkg

= the radiation monitor background reading, in cpm.

Equation 3.6 provides the methodology to calculate the maximum setpoint for continuous releases such as for the unit vent radiation monitor EMF 36. However, most gaseous releases at Catawba are batch releases, e.g., Containment Purge (VP), in which the radiation monitor setpoint is calculated based on actual activity expected in the release.

For batch releases with a low activity release rate the expected monitor response is essentially no greater than background, and the trip setpoints are based on minimum detectable activity.

For batch releases where the effluent can contain activity significantly above background the following setpoint methodology is used:

CXe-133= Z(cG x Eq,)

Expected Cpm = (Cxe -133 x CFxe - 133) + bkg Equation 3.7 "Trip" setpoints are set based on a multiplier factor above the "expected" cpm calculated in Equation 3.7.

where:

CXe-133

= Xe-133 equivalent concentration, in ptCi/ml.

Eqi

= Xe-133 equivalence factor for each isotope, excluding tritium, to that of Xe-133 due to different beta energies and abundance. (See Table 3.0-3).

All other parameters were previously defined.

Section 3 - Page 7

Catawba Nuclear Station January, 2010 Offsite Dose Calculation Manual (ODCM)

Revision 52 3.0.2.1 CONTAINMENT AIR RELEASE AND ADDITION (VO)

SETPOINTS (EMF 39. EMF 36)

As shown on Figure 2.0-3, EMF 39 (when operable) and EMF 36 (when EMF 39 is inoperable) are the controlling radiation monitors for VQ releases from Containment to the Unit Vent. EMF 39 setpoints for VQ releases are calculated as follows:

Expected cpm = (Cxe - 13x CF) + bkg Trip 2 = (Cxe-133 x CF x 2.0) + bkg Trip] = Trip2 x 0.7 Where CF for EMF 39 = 2.70E+07 cpm/! tCi/ml.

For EMF 39 if the Xe-133 equivalent is < 2.OE-05 gtCi/ml, then 2.OE-05 ýtCi/ml is used in the Trip 1 and 2 setpoint calculations.

This is an indication of low' activity in containment, and normal EMF fluctuation may cause Trip 2 alarms and release termination. If EMF 39 is inoperable for a VQ release then the unit vent radiation monitor, EMF 36, is the controlling EMiF for the release.

When EMF 36 must be used as the controlling monitor for VQ releases only the "expected" cpm is calculated using the actual Xe-133 equivalent concentration, and the EMF counts are monitored manually during the VQ release. If the EMF 36 reading significantly exceeds the expected cpm then the release is manually terminated. The EMF 36 expected cpm from VQ activity is calculated as follows:

350 cfm x Cxe-133 x CFXe-133 Expected cpm =

+ bkg Ftuv where:

CXe.133

= Xe-133 equivalent concentration, in giCi/ml.

CFx,.133 = EMF 36 Xe-133 correlation factor, 2.70E+07 cpm/p.Ci/ml.

bkg

= Background reading from EMF 36.

350 cfm = Maximum VQ flow rate.

Fuv

= Current Unit Vent flow rate.

Section 3 - Page 8

Catawba Nuclear Station January, 2010 Offsite Dose Calculation Manual (ODCM)

Revision 52 3.0.2.2 CONTAINMENT PURGE (VP) AND INCORE PURGE (IP)

SETPOINTS (EMF 39. EMF 36)

As shown on Figure 2.0-3 EMF 39 (when operable) and EMF 36 (when EMF 39 is inoperable) are the controlling radiation monitors for VP and IP releases from Containment to the Unit Vent.

EMF 39 setpoints for VP and IP releases are calculated as follows:

Expected cpm = (Cxe -133 x CF) + bkg Trip 2 = (CXe-133 x CF x 2.0) + bkg Trip] = Trip 2 x 0.7 Where CF for EMF 39= 2.70E+07 cpm/ pCi/ml.

For EMF 39 if the Xe-133 equivalent is _<

4.37E-04 pCi/ml, then 4.37E-04 p.Ci/ml is used in the Trip 1 and 2 setpoint calculations.. A Xe-133 equivalent concentration of 4.37E-04 ptCi/ml equates to a dose rate of -5 mr/hr in containment. Typically the dose rate in containment during an outage is -1 or 2 mr/hr, but the higher setpoint based on -5 mr/hr prevents spurious VP trips due to normal evolutions that can occur in containment during the course of an outage. If EMF 39 is inoperable for a VP or IP release then the unit vent radiation monitor, EMF 36, is the controlling EMF for the release.

When EMF 36 must be used as the controlling monitor for VP or IP releases only the "expected" cpm is calculated using the actual Xe-133 equivalent concentration, and the EMF counts are monitored manually during the VP or IP release. If the EMF 36 reading significantly exceeds the expected cpm then the release is manually terminated. The EMF 36 expected cpm from VP or IP activity is calculated as follows:

2.6E+04 cfm x Cx-33 x CFXe-133 Expected cpm =

+ bkg Fuv where:

CXe-133

= Xe-i 33 equivalent concentration, in jiCi/ml.

CFxe-l3 3

= EMF 36 Xe-133 correlation factor, 2.70E+07 cpm/pCi/ml.

bkg

= Background reading from EMF 36.

2.6E+04 cfm = Maximum VP or IP flow rate.

FUV

= Current Unit Vent flow rate.

,Section 3 - Page 9

Catawba Nuclear Station January, 2010 Offsite Dose Calculation Manual (ODCM)

Revision52 3.0.2.3 WASTE GAS DECAY TANK (WGDT) SETPOINTS (EMF 50, EMF 36)

As shown on Figure 2.0-3, EMF 50 (when operable) and EMF 36 (when EMF 50 is not operable) are the controlling radiation monitors for WGDT releases to the Unit Vent.

EMF 50 setpoints are based on actual tank activity, and are calculated as follows:

Expected cpm = (Cxe-133 x CFxe-133) + bkg Trip 2 setpoint (Cxe -133 X CFXe -133 x 3.0) + bkg Trip] = Trip2 x 0.7 where:

CXe-133

= Xe-133 equivalent concentration, in ýiCi/ml.

CFxe-133 = EMF 50 Xe-133 correlation factor, 1.75E+08 cpm/pCi/ml.

bkg Background reading from EMF 50.

For EMF 50 if the Xe-133 equivalent concentration is < 1.OOE-05 plCi/ml, then 1.OOE-05 is used in the Trip 1 and Trip 2 setpoint calculations. This is an indication of a low activity tank, and normal EMF fluctuation may cause Trip 2 alarms and release termination.

The unit vent gas radiation monitor, EMF 36, is used as the controlling monitor for WGDT releases if EMF 50 is inoperable. When EMF 36 must be used as the controlling monitor for WGDT releases only the "expected" cpm is calculated using the actual Xe-133 equivalent concentration, and the EMF counts are monitored manually during the WGDT release. If the EMF 36 reading significantly exceeds the expected cpm then the release is manually terminated. The EMF 36 expected cpm from WGDT activity is calculated as follows:

=50 cfm x Cxe -133 x CFxe-133 Expected cpm

+ bkg Fuv" where:

CXe-133

= Xe-133 equivalent concentration, in jiCi/ml.

CFX,-133 = EMF 36 Xe-133 correlation factor, 2.70E+07 cpm/laCi/ml.

bkg

= Background reading from EMF 36.

50 cfin

= Maximum Waste Gas flow rate.

Fuv

= Current Unit Vent (Ul) flow rate.

Section 3 - Page 10

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 Table 3.0-3 Xe-133 Equivalents Isotop~e Equivalence~

Factor, Kr-83m 0.0 Kr-85m 2.14 Kr-85 2.56 Kr-87 2.93 Kr-88' 2.74 Kr-89 2.93 Kr-90 2.90 Xe-131m 1.65 Xe-133m 1.98 Xe-133 1.0 Xe-135m 0.56 Xe-135 2.63 Xe-137 2.93 Xe-138 2.93 Ar-41 2.93 Section 3 - Page 11

Catawba Nuclear Station January, 2010 Offsite Dose Calculation Manual (ODCM)

'Revision 52 4.0 EFFLUENT DOSE MODELS The effluent dose models used to show compliance with 10CFR50, Appendix I ALARA design objectives, 40CFR190 fuel cycle dose limits, and the dose values given in station SLCs are based on the methodology given in NUREG-0 133 and Regulatory Guide 1.109.

Dose contributions to the maximum individual shall be calculated at least every 31 days, quarterly, and annually using the RETDAS computer code which implements the ODCM methodology. RETDAS, Radioactive Effluent Tracking and Dose Assessment Software, is a database application designed by Canberra Industries, Inc. to automate many of the tasks required in the administration of effluent releases at Catawba. RETDAS performs normal operation effluent dose assessment using NUREG-0133 and Regulatory Guide 1.109 methodology.

Station long-term historical and dose projection calculations are performed periodically to determine the station's status with respect to meeting annual ALARA goals specified in the Catawba SLCs. Such calculations are used to verify that adequate margin remains during a report period to allow normal station and radwaste system operation, including anticipated operational occurrences, for the remainder of the report period without exceeding applicable goals. Station 31-day dose projections that are used to assess the need to reduce effluent releases with the Gaseous Waste (WG) or Liquid Waste (WL) systems as required in the Catawba SLCs are estimated by the previous month's calculated dose results:

Fuel cycle dose calculations shall be performed annually or as required by special reports.

Dose contributions shall be calculated using the RETDAS computer program.

4.0.1 LIQUID EFFLUENT DOSE MODEL FOR THE MAXIMUM EXPOSED INDIVIDUAL Of the possible exposure pathways in the aquatic environment, only three contribute significantly to the total dose; these pathways are ingestion of potable water and aquatic foods, and direct exposure from radioactivity-deposited on the shoreline.

The dose contribution from these pathways for measured quantities of radioactive materials identified in liquid effluents released to unrestricted areas shall be calculated for the maximum exposed individual in each age group using the methodology provided in this section.

There are two liquid discharge points to the environment at Catawba; (1) the Low Pressure Service Water System (RL) and Nuclear Service Water System (RN) discharge point to Lake Wylie, and (2)r the Conventional Waste Water Treatment System (WC) discharge point to Lake 'Wylie (See Figure 2.0-1).

Liquid dose calculations for the maximum exposed individual are performed and documented in the Annual Effluent Release Report for both locations using the applicable activity release and dilution data Section 4 - Page I

Catawba Nuclear Station January, 2010 Offsite Dose Calculation Manual (ODCM)

Revision 52 for each liquid effluent release point. The primary liquid effluent discharge point for Catawba is through RL/RN to Lake Wylie. In general, only low activity tritium releases

(<1% station total) occur through the WC discharge point to Lake Wylie.

Dose calculations are performed for each of the two liquid discharge points for dose reporting purposes. The highest calculated dose from the two dose calculations is used to define the maximum individual dose from liquid releases at Catawba.

Section 4 - Page. 2

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 Liquid Dose Calculations The following equation is used for calculating liquid dose individual at each of the two liquid effluent release points:

to the maximum exposed Doseoa = i (Aoapi p

i F,+fxo" f+F X Ci) x At x F, x 1

Dw Formula:, adapted from NUREG-0133, pages 15-17.

Where:

Doseoa The cumulative dose commitment for organ o and age group a, from the liquid effluent for the total time period, At. (mrem)

Aoapi Dose commitment factor for organ o, age group a, pathway p, and nuclide i (mrem/hr per ptCi/ml). (See Appendices C through F for age group and pathway specific dose commitment factors).

Ci The average concentration of nuclide i, in undiluted liquid effluent during the time period, At. ([tCi/ml)

At The length of time over which Ci and F, are averaged for all liquid releases. (hr)

F, The near field average dilution factor for Ci during the period of interest, At. Includes the recirculation factor. (dimensionless) f Average liquid radwaste flow during the period of interest, At. (gpm)

F Average dilution flow during the period of interest, At. (gpm)

RL/RN primary discharge location: RI/RN average dilution flow WC discharge location: 10% of RL/RN average dilution flow Y Recirculation factor.* (dimensionless)

D, Dilution factor from the near field area to the potable water intake; = 43.4 for Catawba. This factor applies to the potable water pathway only.

The factor is calculated by (Average Wylie Dam Flow (4453 cfs) +

Average Radwaste Flow (105 cfs)) divided by the (Average Radwaste Flow (105 cfs)). This value can be modified to account for deviations from average in a particular year, or for added conservatism such as accounting for minor radioactivity contributions from McGuire Nuclear Station. A Dw value of 10 is currently being used.

  • The recirculation factor accounts for the fraction of discharged water reused by the station. Liquid effluent discharge cannot be recirculated back into the Catawba station.

Therefore, the recirculation factor is 1.0 at Catawba.

Section 4 - Page 3

Catawba Nuclear Statiorn Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 Derivation of Liquid Dose Commitment Factors (Aoapi)

Potable Water Aoapi = 1.14 x 105 x Uaw x Oaoi x e-2tp Formula: from NUREG-0133, page 16, and Regulatory Guide 1109,

e.

p

.109-12.

mWhere:*

Aoapi Dose commitment factor for organ o, age group a, pathway p, and nuclide i, (mrem/hr per VCi/ml). (See Appendices C through F for age group and pathway specific dose commitment factors).

1.14x 105 Units conversion factor (pCi-yr-ml)/(jtCi-hr-kg).

Uaw Water consumption rate in liters per year for age group a. From Table E-5, Regulatory Guide 1.109.

Adult - 730 Teen - 510 Child - 510 Infant - 330 Daoi Dose factor for age group a, organ o, nuclide i, in mrem/pCi. From tables E-11 through E-14 of Regulatory Guide 1.109.

Xi Decay constant for nuclide i, in sec'.

tp Environmental transit time from release to receptor. Default =

4.32E+04 sec (12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />). From Regulatory Guide 1.109, Table E-15.

Section 4 - Page 4

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 Aquatic Foods

-p1.14xIO 5 xU B

o tp Aoap 1.4 x OSX Uf x BFi x Daoi x e-Formula:, from NUREG-0133, page 16, and Regulatory Guide 1.109, page 1.109-12..,

Where:.

Aoapi Dose commitment factor for organ o, age group a, pathway p, and nuclide i, (mrem/hr per pCi/ml).

(See Appendices C through F for age group and pathway specific dose commitment factors).

1.14x 105 Units conversion factor (pCi-yr-ml)/(pLCi-hr-kg).

Uaf Fish consumption rate for age group a (kg/yr). From Table E-5, Regulatory Guide 1.109.

Adult - 21 Teen - 16 Child - 6.9 Infant - 0 BFi Bioaccumulation factor for nuclide i, in fish, in units of pCi/kg per pCi/liter. From Table A-I of Regulatory Guide 1.109.

Daoi Dose factor for age group a, organ o, nuclide i, in mrem/pCi. From tables E-11 through E-14 of Regulatory Guide 1.109.

ki Decay constant for nuclide i, in sec-'.

tp Environmental transit time from release to receptor. Default=

8.64E+04 sec (1 day). From Regulatory Guide 1.109, Table E-15.

Section 4 - Page 5

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 Shoreline Sediment 1

Aoapi= 1.14x1 5 1OOxDFGoi xwxU0 s xI x e-t xx(1-e-tb)

Formula: adapted from Regulatory Guide 1.109, page4.109-14.

Where:

Aoapi Dose commitment factor for organ o, age group a, pathway p, and nuclide i, (mrem/hr per pCi/ml). (See Appendices C through F for age group and pathway specific dose commitment factors).

1.14x 105 Units conversion factor (pCi-yr-ml)/([tCi-hr-kg).

100 Proportionality constant used in the sediment radioactivity model, (liters/(m2-day).

DFGoi Ground plane dose conversion factor for organ o, nuclide i (mrem/hr per pCi/mi2), from Table E-6 of Regulatory Guide 1.109.

w Shoreline width factor. For Catawba = 0.3, from Table A-2, Regulatory Guide 1.109.

Uas Shoreline exposure rate for age group a (hr/yr), From Table E-5, Regulatory Guide 1.109.

Adult-12 Teen - 67 Child-14 Infant - 0 TiV2 Nuclide half life for nuclide i, in days.

,i Nuclide decay constant for nuclide i.

tp Average transit time to point of exposure (0 hours0 days <br />0 hours <br />0 weeks <br />0 months <br />).

tb Sediment exposure time (15 years). Page 1.109-14.

Section 4 - Page 6

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 4.0.2 GASEOUS EFFLUENT DOSE MODEL FOR THE MAXIMUM EXPOSED INDIVIDUAL The dose contributions from measured quantities of radioactive materials identified in gaseous effluent released to unrestricted areas shall be calculated for the maximum gamma and beta air dose from noble gases, and for the maximum exposed individual from radioiodines, particulates, and others using the following equations:

Gaseous Dose Calculations Noble Gas Dose Calculations Gamma Air Dose Dose, =3.17x10 8 xX/Qx-(M1 xQJ)

Formula: adapted from.NUREG-0133, page 28 Where:

Dose, Gamma air dose for the time period of interest (mrad).

3.17x 10-8 Inverse number of seconds in year (year/seconds).

Mi Gamma air dose factor due to gamma emissions for nuclide i (mrad/yr per _Ci/m3). (See Appendix A).

x/Q Thekhighest calculated annual average relative concentration for any area at or beyond the site boundary (sec/m 3). (See Table 6.0-8).

Qi Activity for nuclide i released during the time period of interest (ýtCi).

Beta Air Dose Dose = 3.17x10 8 xx/l x (NixQi)

Formula: adapted from NUREG-0133, page 28..

Where:

Dosep Beta air dose for the time period of interest (mrad).

3.17x 108 Inverse number of seconds in year (year/seconds).

Ni Beta air dose factor due to beta emissions for nuclide i (mrad/yr per

_ACi/m 3). (See Appendix A).

X/Q The highest calculated annual average relative concentration for any I area at or beyond the site boundary (sec/m 3). (See Table 6.0-8).

Qi Activity for nuclide i released during the time period of interest (ýtCi).

Section 4 - Page 7

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 Iodine, Particulates, and H-3 Dose Organ Dose Calculation Doseoa = 3.17x1O-8 xW x I (Roapi XQi) p i

Formula: adapted from N G-0133, pages 29& 30.

Where:

Doseoa The cumulative dose commitment to the total body or any organ o, for an individual of age group a (mrem).

3.17x 10-8 Inverse number of seconds in year (year/seconds).

Roapi Dose commitment factor for organ o, age group a, pathway p, and nuclide i. The units are based on whether a dispersion or deposition factor is used. When a X/Q is used the units are mrem/yr per VtCi/m 3'.

When a D/Q is used the units are (m2. mrem/yr) per p.Ci/sec. (See Appendices G through J for age group and pathway specific dose commitment factors).

W Dispersion (x/Q) or deposition factor (D/Q). The factor used is based upon the pathway. Note: x/Q is always used for tritium.

Pathway Factor Used Ground Plane Deposition D/Q (M-2 )

Inhalation x/Q (sec/m 3)

Vegetation D/Q (mi2 )

Grass/Cow/Milk D/Q (Mi 2)

Grass/Goat/Milk D/Q (M' 2)

Grass/Cow/Meat D/Q (mi2)

Qi Activity for nuclide i, released during the time period of interest (jtCi).

Maximum individual organ dose is determined by calculating the organ dose at each of the X/Q and D/Q locations shown in Table 6.0-8 and Table 6.0-9 (144 locations), and then choosing the maximum dose. Dose is calculated only for pathways (e.g., garden, milk animal, etc.) that actually exist at each location as determined by the land use census shown in Table 6.0-3. As discussed in Catawba UFSAR Section 2.1.1.3, the boundary for establishing gaseous effluent release limits is the exclusion area boundary (EAB). The EAB is defined as a 2500-ft. (-0.5 mile) r'adius from the station center.

Section 4 - Page 8

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 Derivations of Iodine, Particulate, and H-3 Dose Commitment Factors (Roapi)

Ground Plane Deposition Pathway Roap= K'K"(SF)DFG, [(1-e jt Formula: from NUREG-0133, page 32.

Where:

Roapi Dose, commitment factor for organ o, age group a, nuclide i, for ground plane deposition pathway (m2 mrem/yr per 1iCi/sec). (See Appendices G through J for age group and pathway specific dose commitment factors).

K' Units conversion factor pCi/ptCi (106).

K" Units conversion factor 8760 hr/year.

SF Shielding factor (dimensionless) (0.7, from Regulatory Guide 1.109).

DFGoi Ground plane dose conversion factor for organ o, nuclide i (mremlhr per pCi/m2), from Table E-6 of Regulato 7 Guide, 1.109.

Xi Nuclide decay constant for nuclide~i (sec-),

t Exposure time, 4.73x 108 seconds (15 years).

Inhalation Pathway Roapi = K'(BRa)(DFAoi)a Formula: from NUREG-0133, page 31.

Where:

Roapi Dose commitment factor for organ o, age group a, nuclide i, for.

inhalation pathway (mrem/yr per PtCi/m 3). (See Appendices G.

through J for age group and pathway specific dose commitment factors).

K' Units conversion factor pCi/ýtCi (106).

BRa Breathing rate for age group (m3/yr), from Regulatory Guide 1.109:

Adult - 8000 Teen-8000 Child - 3700 Infant-1400 (DFAoj)a Organ inhalation factor dose conversion factor for organ o, nuclide i, age group a (mrem/pCi), from Tables E-7 through E-10 of Regulatory Guide 1.109.

Section 4-Page 9

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 Vegetation R

= K (Ir) x (DFL o)a x [ULfLe,AL + Ufge2Ith]

Formula: from NIJREG-0133 pae3.Where:

Roapi Dose commitment factor for organ o, age group a, nuclide i, for vegetation pathway (mEnmrem/yr per pCi/sec). (See Appendices G through J for age group and pathway specific dose commitment factors).

K' Units conversion factor pCi/ptCi (106).

r Fraction of deposited activity retained on vegetation, from Regulatory Guide 1.109.

1.0 for radioiodine.

0.2 for particulates.

Yv Vegetation areal density (kg/m 2) (2.0, from Regulatory Guide 1.109).

Xi Nuclide decay constant for nuclide i (sec-').

X*, Decay constant for removal of activity on leaf and plant surfaces by weathering (5.73x 10-7 sec-1, from NUREG-0 133).

(DFLoi)a Ingestion dose conversion factor for nuclide i, organ o, and age group a, from Tables E-11 through E-14 of Reg. Guide 1.109 (mrem/pCi).

ULa Consumption rate of fresh vegetation for age group a (kg/yr) (from Regulatory Guide 1.109).

Adult - 64 Teen - 42 Child - 26 Infant - 0 fL Fraction of annual intake of fresh leafy vegetation grown locally (1.0, from NUREG-0133).

tL Average time between harvest of leafy vegetation and consumption (8.6x1i0 4 seconds, (1 day), from Regulatory Guide 1.109).

USa Consumption rate of stored vegetation for age group a (kg/yr) (from Regulatory Guide 1.109).

Adult - 520 Teen - 630 Child - 520 Infant - 0 fg Fraction of annual intake of stored vegetation (0.76, from Regulatory Guide 1.109).

th Average time between harvest of stored vegetation and consumption I (5.18x106 seconds, (60 days), from Regulatory Guide 1.109).

Section 4 - Page 10

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 Vegetation - Tritium Roapi = K' K'"[UafL +US fg](DFLoi)a[O.75(O.5/H)]

Formula: from NUREG-0133, page 36.

Where:

Roapi Dose commitment factor for organ o, age group a, for vegetation pathway and tritium (mrem/yr per [tCi/m 3). (See Appendices G through J for age group and pathway specific dose commitment factors).

K' Units conversion factor pCi/tCi (106).

K.' Units conversion factor gm/kg (10*).

ULa Consumption rate of fresh vegetation for age group a (kg/yr) (from Regulatory Guide, 1.109).

Adult - 64 Teen - 42 Child - 26 Infant - 0 fL Fraction of annual intake of fresh leafy vegetation grown locally (1.0, from NUREG-0133).

Usa Consumption rate of stored vegetation for age group a (kg/yr) (from Regulatory Guide 1.109).

Adult - 520 Teen-630 Child - 520 Infant - 0 fg Fraction of annual intake of stored vegetation (0.76, from Regulatory Guide 1.109).

(DFLoi)a Ingestion dose conversion factor for nuclide i, organ o, and age group a, from Tables E-1 1 through E-14 of Regulatory Guide 1.109 (mrem/pCi).

0.75 Fraction of total feed that is water. (From NUREG-0 133).

0.5 Ratio of specific activity of feed grass water to atmospheric water.'

(From NUREG-0133).

H Absolute humidity of the atmosphere (8 gm/m 3, from Regulatory Guide 1.109).

Section 4 - Page II

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 Grass/Cow/Milk Roapi K'

F (U

) F,, (

DFL O) fp f, + (1 -e Ai+Yp Y,

Formula: from NULREG-0133, pages 32 & 33. Where:

Roapi Dose commitment factor for organ o, age group a, nuclide i,(for grass/cow/milk pathway (Mi2 mrem/yr per pCi/sec). (See Appendices G through J for age group and pathway specific dose commitment factors).

K' Units conversion factor pCi/ýtCi (106).

QF Cow consumption rate (50 kg/day, from Regulatory Guide 1.109)

.:Uap Consumption rate of cow milk for age group a (liters/yr, from Regulatory Guide 1.109).

Adult - 310 Teen-400 Child - 330 Infant - 300 r Fraction of deposited activity retained on cow's feed grass, (from Regulatory Guide 1.109).

1.0 for radioiodine.

0.2 for particulates.

Yp Agricultural productivity by unit area of pasture feed grass (0.7 kg/m2, from Regulatory Guide 1.109).

Ys Agricultural productivity by unit area of stored feed (2.0 kg/m2, from Regulatory Guide 1.109).

X* Nuclide decay constant for nuclide i (secl).

xw Decay constant for removal of activity on leaf and plant surfaces by weathering (5.73x 10-7 sec"1, from NUREG-0133).

(DFLoi)a Ingestion dose conversion factor for nuclide i, organ o, and age group a,from Tables E-1 1 through E-14 of Regulatory Guide 1.109 (mrem/pCi).

Fmi Stable element transfer coefficient for nuclide i, in days/liter, from Table E-I of Regulatory Guide 1.109 for cow milk.

f, Fraction of year that the cow is on pasture (1.0, from RG 1.109).

f, Fraction of the cow feed that is pasture grass while the cow is on pasture (1.0, from Regulatory. Guide 1.109).

tf Transport time for pasture to cow, to milk, to receptor (1.73E+05 seconds, from Regulatory Guide 1.109).

th Transport time from pasture, to harvest, to cow, to milk, to receptor (7.78E+06 seconds, from Regulatory Guide 1.109).

Section 4 - Page, 12

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 Grass/Cow/Milk - Tritium Roapi = K' K '" FmiQfUap ( FLio)a [0.75 (0.5 / H)]

Formula: from NUREG-Oi3.3, page 34.

Where:

Roapi Dose commitment factor for organ o, age group a, nuclide i, for grass/cow/milk pathway (mrem/yr per tCi/mn3). (See Appendices G through J for age group and pathway specific dose commitment factors).

K' Units conversion factor. pCi/tCi (106).

K.' Units conversion.factor gm/kg (10-).

/

QF Cow consumption rate (50 kg/day, from Regulatory Guide 1.109).

Uap Consumption rate of cow milk for age group a (liters/yr, from Regulatory Guide 1.109).

Adult - 310 Teen-400 Child - 330 Infant - 300 (DFLoi)a Ingestion dose conversion factor for nuclide i, organ o, and age group a, from Tables E-Il through E-14 of Regulatory Guide 1.109 (mrem/pCi).

Fmi Stable element transfer coefficient for nuclide i, in days/liter, from Table E-1 of Regulatory Guide 1.109 for cow milk.

0.75 Fraction of total feed that is water (from NUREG-0133).

0.5 Ratio of specific activity of feed grass water to atmospheric water

_(from NUREG-0133).

H Absolute humidity of the atmosphere (8 gm/m 3, from Regulatory Guide 1.109).

Section 4 - Page 13

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 Grass/Goat/Milk Roapi =K QF(gp)Fmi(r)(DFLoi)al fPfs

+

(

fPfs)e the

-jtf Ai +

w Yp Y,

Formula:, from NUREG-0133, pages 32 & 33. Where:

Roapi Dose commitment factor for organ o, age group a, nuclide i, for grass/goat/milk pathway (m2-mrem/yr per ptCi/sec). (See Appendices G through J for age group and pathway specific dose commitment factors).

K' Units conversion factor pCi/ýtCi (106).

/

QF Goat consumption rate (6 kg/day, from Regulatory Guide 1.109).

Uap Consumption rate of goat milk for age group a (liters/yr, from Regulatory Guide 1.109).

Adult - 310 Teen-400 Child - 330 Infant - 300 r Fraction of deposited activity retained on goat's feed grass, from Regulatory Guide 1. 109.

1.0 for radioiodine.

0.2 for particulates.

Yp Agricultural productivity by unit area of pasture feed grass (0.7 kg/M2, from Regulatory Guide 1.109).

Y, Agricultural productivity by unit area of stored feed (2.0 kg/m2, from Regulatory Guide 1.109).

X* Nuclide decay constant for nuclidei (seci).

X* Decay constant for removal of activity on leaf and plant surfaces by weathering (5.73x 10-7 sec-1, from NUREG-0133).

(DFLoi)a Ingestion dose conversion factor for nuclide i, organ o, and age group a, from Tables E-1 1 through E-14 of Regulatory Guide 1.109 (mrem/pCi).

Fmi Stable element transfer coefficient for nuclide i, in days/liter, from Table E-2 of Regulatory Guide 1.109 for goat milk.

fy Fraction of year that the goat is on pasture (1.0, from RG 1.109).

f, Fraction of the goat feed that is pasture grass while the goat is on pasture (1.0, from Regulatory Guide 1.109).

tf Transport time for pasture to goat, to milk, to receptor (1.73E+05 seconds, from Regulatory Guide 1.109).

th Transport time from pasture, to harvest, to goat, to milk, to receptor (7.78E+06 seconds, from Regulatory Guide 1.109).

Section 4 - Page 14

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 Grass/Goat/Milk - Tritium Roapi = K' K"' FmiQfUap (DFLoi)a [0.75(0.5 / H)]

Formula: from NUREG-0133, page 34.

Where:

Roapi Dose commitment factor for organ o, age group a, nuclide i, for grass/goat/milkpathway (mrem/yr per jtCi/m3). (See Appendices G through J for age group and pathway specific dose commitment factors).

K' Units.conversion factor pCi/Ci (106).

K"'

Units conversion factor gm/kg (10').

QF Goat consumption rate (6 kg/day, from Regulatory Guide 1.109).

Uap Consumption rate of goat milk for age group a (liters/yr, from Regulatory Guide 1.109).

Adult - 310 Teen-400 Child - 330 Infant - 300 (DFLoi)a Ingestion dose conversion factor for nuclide i, organ o, and age group a, from Tables E-11 through E-14 of Regulatory Guide 1.109 (mrem/pCi).

Fmi Stable element transfer coefficient for nuclide i, in days/liter, from Table E-2 of Regulatory Guide 1.109 for goat milk.

0.75 Fraction of total feed that is water (from NUREG-0 133).

0.5 Ratio of specific activity of feed grass water to atmospheric water (from NUREG-0133).

H Absolute humidity of the atmosphere (8 gm/m3, from Regulatory Guide 1.109).

Section 4 -Page 15

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 Grass/Cow/Meat Rapi K,QF(Uap)F (r)(DFL ff (1-fpfs)e-Ath j-Atf Formula: from NUREG-0133, pages 34,&,35.. Where:

Roapi Dose commitment factor for organ o, age group a, nuclide i, for 2

grass/cow/meat pathway (m.mrem/yr per jiCi/sec). (See Appendices G through J for age group and pathway specific dose commitment factors).

K' Units conversion factor pCi/ptCi (106).

QF Cow consumption rate (50 kg/day, from Regulatory Guide 1.109).

Uap Consumption rate of cow meat for age group a (kg/yr, from Regulatory Guide 1.109).

Adult - 110 Teen - 65 Child - 41 Infant - 0 r Fraction of deposited activity retained on cow's feed grass (from Regulatory Guide 1.109).

1.0 for radioiodine.

0.2 for particulates.

Yp Agricultural productivity by unit area of pasture feed grass (0.7 kg/m2, from Regulatory Guide 1.109).

Y, Agricultural productivity by unit area of stored feed (2.0 kg/m2, from Regulatory Guide 1.109).

ki Nuclide decay constant for nuclide i (sec).

X, Decay constant for removal of activity on leaf and plant surfaces by weathering (5.73x 10-7 sec"1, from NUREG-0133).

(DFLoi)a Ingestion dose conversion factor for nuclide i, organ o, and age group a, from Tables E-1 1 through E-14 of Regulatory Guide 1.109 (mrem/pCi).

Ffi Stable element transfer coefficient for nuclide i, in days/kg, from Table E-1 of Regulatory Guide 1.109 for cow meat.

f, Fraction of year that the cow is on pasture (1.0, from RG 1.109).

fs Fraction of the cow feed that is pasture grass while the cow is on pasture (1.0, from Regulatory Guide 1.109).

tf Transport time from pasture to receptor (1.73E+06 seconds, from Regulatory Guide 1.109).

th Transport time from crop field to receptor (7.78E+06 seconds, from Regulatory Guide 1.109).

Section 4 - Page 16

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 Grass/Cow/Meat - Tritium Roapi = K' K'" Ff QFUap (DFL oi) a [0.75(0.5 / H)]

Formula.:-.fromNUREG-133, ae5.

Where:

Roapi Dose commitment factor for organ o, age group a, nuclide i, for grass/cow/meat pathway (mrem/yr per ptCi/m 3). (See Appendices G through J for age group and pathway specific dose commitment factors).

K' Units conversion factor pCi/pCi (106).

K.' Units conversion factor gm/kg (103).

QF Cow consumption rate (50 kg/day, from Regulatory Guide 1.109).

Uap Consumption rate of cow meat for age group a (kg/yr, from Regulatory Guide 1.109).

Adult - 110 Teen - 65 Child-41 Infant - 0 (DFLoi)a Ingestion dose conversion factor for nuclide i, organ o, and age group a, from Tables E-1 1 through E-14 of Regulatory Guide 1.109 (mrem/pCi).

Ffi Stable element transfer coefficient for nuclide i, in days/liter, from Table E-1 of Regulatory Guide 1.109 for cow meat.

0.75 Fraction of total feed that is water (from NUREG-0 133).

0.5 Ratio of specific activity of feed grass water to atmospheric water (from NUREG-0133).

H Absolute humidity of the atmosphere (8 gm/rnm 3, from Regulatory I Guide 1.109).

/

Section 4 - Page 17

Catawba Nuclear Station January, 2010 Offsite Dose Calculation Manual (ODCM)

Revision 52 4.0.3 DIRECT RADIATION Direct radiation is that radiation from confined sources, and does not' include any eiternal component from radioactive effluents.

The Point Kernel method has been used to calculate offsite dose rates from radioactive materials stored in the refueling water storage tanks, reactor makeup water storage tanks, and temporary onsite radwaste storage tanks.

Dose calculations using this method performed for Catawba Nuclear Station indicate direct radiation doses are much less than 0.01 mrem/yr and, therefore, make a negligible contribution to individual dose. Likewise, direct and air-scatter radiation dose contributions from the onsite Independent Spent Fuel Storage Installation '(ISFSI) at Catawba have, been calculated and documented in the "Catawba Nuclear Site ISFSI 10CFR72.212 Evaluation" report. The estimated ISFSI cask loading schedule is given in three phases. For Phase I initial ISFSI cask loading began in July 2007 and is scheduled to be completed by the end of 2011.

Estimated dose rates at 50 specific locations including the Exclusion Area Boundary (EAB) are provided in the 10CFR72.212 evaluation report. The maximum dose rate at the EAB for Phase I from the Catawba ISFSI is calculated to be less than 0.1 mrem/yr.

Direct radiation doses will not, be calculated routinely.

4.0.4 EFFLUENT APPORTIONMENT For the Catawba Nuclear Station the effluent releases are apportioned equally to each unit for each site as recommended by Section 3.1 of NUREG-0133, because the shared radwaste treatment systems at each site make it impractical to accurately ascribe releases to a specific. reactor unit. For Annual Radiological Effluent Release Report purposes effluent releases are summed for each unit, and the maximum individual dose to the public is reported as a site total.

Section 4 -Page 18

Catawba Nuclear Station January, 2010 Offsite Dose Calculation Manual (ODCM)

Revision 52 5.0 FUEL CYCLE CALCULATIONS In accordance with the requirements of 40CFR190, the annual dose commitment to any member of the general public shall be calculated to assure that doses are limited to 25 millirems to the total body or any organ with the exception of the thyroid which is limited to 75 millirems.

In accordance with the requirements of the Selected Licensee Commitments, the annual dose commitment shall also be calculated any time that one of the quarterly dose limits of the Selected Licensee Commitments is exceeded; these annual dose commitments may not just be calculated for the calendar year.

The "Uranium fuel cycle" is defined in 40CFR Part 190.02(b) as:

"Uranium fuel cycle means the operations of milling of uranium ore, chemical conversion of uranium, isotopic enrichment of uranium, fabrication of uranium fuel, generation of electricity by a light-water-cooled nuclear power plant using uranium fuel, and reprocessing of spent uranium fuel, to the extent that these directly support the production of electrical power for public use utilizing nuclear energy, but excludes mining operations, operations at waste disposal sites, transportation of any radioactive material in support of these operations, and the reuse of recovered non-uranium special nuclear and by-product materials from the cycle."

Based on this definition of the fuel cycle and the information in 10CFR51, Table S-3, and Wash-1248, the radiological impact of the following operations has been assessed for Catawba Nuclear Station:

5.0.1 MILLING No milling operations occur within fifty miles of the Catawba Nuclear Station.

5.0.2 CONVERSION No uranium hexafluoride production occurs within fifty miles of the Catawba Nuclear Station.

5.0.3 ENRICHMENT No uranium enrichment operations occur within fifty miles of the Catawba Nuclear Station.

5.0.4 FUEL FABRICATION No fuel fabrication operations occur within fifty miles of the Catawba Nuclear Station.

Section 5 - Page 1

Catawba Nuclear Station January, 2010 Offsite Dose Calculation Manual (ODCM)

Revision 52 K

5.0.5 NUCLEAR POWER PRODUCTION The production of electricity for public use using light-water-cooled nuclear power stations results in increments of dose to individuals within fifty miles of any station due to liquid and gaseous effluent releases and direct radiation or skyshine. The increments of dose resulting from liquid and gaseous effluent releases will be calculated using the ODCM methodology implemented in the RETDAS computer program. The dose from direct radiation, skyshine, and radiation from the station storage facilities has been estimated using conservative assumptions (see Section 4.0.3).

In certain situations more than one nuclear power station site may contribute to the doses to be considered in making fuel cycle dose assessments in accordance with 40CFR190.

However, since the Catawba and McGuire nuclear stations are located approximately 30 miles apart the relative dose contribution from each site to the other is insignificant, and can be ignored in assessing compliance with 40CFR190.

5.0.6 FUEL REPROCESSING No fuel reprocessing operations occur within fifty miles of the Catawba Nuclear Station.

5.0.7 40CFR190 TOTAL DOSE DETERMINATION To summarize, only dose increments from nuclear power production operations (Section 5.0.5) need be considered in calculations to demonstrate compliance with the requirements of.40CFR190.

The fuel cycle dose assessments for Catawba Nuclear Station only include liquid and gaseous dose contributions from Catawba and dose from Catawba's ISFSI since no other uranium fuel cycle facility contributes significantly to Catawba's maximum exposed individual. For this dose assessment, the total body and maximum organ dose contributions to the maximum exposed individual from Catawba's liquid and gaseous effluents are estimated using the following calculations:

Dwb(T) = DRb(l) + Dwb(g)

Dmo(T) = Do(l) + Dmo(g) where:

Dwb(T) = Total estimated fuel cycle whole body dose commitment resulting from the combined liquid and gaseous effluents of Catawba during the calendar year of interest, in mrem.

Dmo(T) = Total estimated fuel cycle maximum organ dose commitment resulting from the combined liquid and gaseous effluents of Catawba during the calendar year of interest, in mrem.

Section 5 - Page 2

Catawba Nuclear Station January, 2010 Offsite Dose Calculation Manual (ODCM)

Revision 52 6.0 ENVIRONMENTAL LOCATIONS 6.0.1 SITE DESCRIPTION AND SAMPLE LOCATIONS Catawba Nuclear Station is located geographically near the center of a highly industrialized region of the Carolinas.

The land is predominantly rural non-farm with a small amount of land being used to support beef cattle and farming.

Recreation in the area is confined mostly to the lake and shores of Lake Wylie. The site is located in the northeastern portion of York County, South

Carolina, on a

peninsula bounded by Beaver Dam Creek Fish Sampling to the north, Big Allison Creek to the south, the main body of Lake Wylie to the east, and private property to the west.

The Duke Power Company Wylie Dam and Hydroelectric Station are located approximately 4.5 miles southeast of the site. Rock Hill, South Carolina and Charlotte, North Carolina are the nearest large cities.

The city limit of Rock Hill is located approximately 5.8 miles south-southeast of the site and the Charlotte city limit is located approximately 10.5 miles east-northeast of the site. The CNS site exclusion radiusis 2500 feet.

Table 6.0-1 and Table 6.0-2 define the sampling and TLD locations for the Catawba Radiological Monitoring Program.

Figure 6.0-1 and Figure 6.0-2 illustrate these locations as compared to Catawba Nuclear Station.

6.0.2 LAND USE CENSUS DATA The Annual Land Use Census, required by Selected Licensee Commitments, is performed to ensure that changes in the use of areas at or beyond the site boundary are identified, and that modifications to the Radiological Environmental Monitoring Program are made if required by changes in land use. This census satisfies the requirements of Section IV.B.3 of Appendix I to 10CFR50. Results are shown in Table 6.0-3 and Figure 6.0-3.

Section 6 - Page 1

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 TABLE 6.0-1 CATAWBA RADIOLOGICAL MONITORING PROGRAM SAMPLING LOCATIONS Table'6.0'1 Codes W

Weekly SM Semimonthly BW BiWeekly Q

Quarterly M

Monthly SA Semiannually C

Control Site Location DesCription*

Air Rad:&

Surface Drinking

- Shoreline Food Fishi Milk Broad,.'

Grourd.

Loctio "escnptio

.Part.-

Water;,

Water'

-ýýSedimient Products.

Leaf GWater 200 Site Boundary (0.63 mi NNE)

W M

201 Site Boundary (0.53 mi NE)

W M

205 Site Boundary (0.23 mi SW)

W 208 Discharge Canal (0.45 mi S)

M SA SA 210 Ebenezer Access (2.31 mi SE)

SA 211 Wylie Dam (4.06 mi ESE)

M 212 Tega Cay (3.32 mi E)

W 214 Rock Hill Water Supply (7.30 mi SSE)

M 215 C River Pointe - Hwy 49 (4.21 mi NNE)

M SA 216 C Hwy 49 Bridge (4.19 mi NNE)

SA 218 C Belmont Water Supply (13.5 mi NNE)

M_

221 C Dairy (14.5 mi NW)

SM 222 Site Boundary (0.70 mi N)

M 226 Site Boundary (0.48 mi S)

M 252 Residence (0.64 mi SW)

Q 253 Irrigated Gardens (1.90 mi SSE)

M(a) 254 Residence (0.82 mi N) 258 C Fairhope Road (9.84 mi W)

W M

(a) During Harvest Season (b) When Available

  • GPS data reflect approximate accuracy to within 2-5 meters. GPS field measurements were taken as close as possible to the item of interest.

Section 6 - Page 2

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 TABLE 6.0-2 CATAWBA RADIOLOGICAL MONITORING PROGRAM SAMPLING LOCATIONS (TLD SITES)

Site Location*

Distance Sector Site Location*

Distance Sectoi 200 SITE BOUNDARY 0.63 miles NNE 234 WACHOVIA BANK 4.50 miles E

201 SITE BOUNDARY 0.53 miles NE 235 LAKE WYLIE DAM 4.07 miles ESE SC WILDLIFE 203 SITE BOUNDARY 0.38 miles ESE 236 FEDERATION OFFICE 4.25 miles SE TWIN LAKES ROAD AND 204 SITE BOUNDARY.

0.48 miles SSW 237 HOMESTEAD ROAD 4.75 miles SSE PENNINGTON ROAD AND 205 SITE BOUNDARY 0.23 miles SW 238 WEST OAK ROAD 4.02 miles

,S CARTER LUMBER 206 SITE BOUNDARY 0.67 miles WNW 239 COMPANY 4.49 miles SSW 207 SITE BOUNDARY 0.95 miles NNW 240 PARAHAM ROAD 4.07 miles SW 212 SI TEGA CAY AIR SITE 3.32 miles E

241 CAMPBELL ROAD 4.58 miles WSW TRANSMISSION TOWER 217 C ROCK HILL AIR SITE 10.3 miles SSE 242 ON PARAHAM ROAD 4.56 miles W

222 SITE BOUNDARY 0.71 miles N

243 KINGSBERRY ROAD 4.39 miles WNW BETHEL 223 SITE BOUNDARY 0.57 miles E

244 ELEMENTARY SCHOOL 4.02 miles NW CROWDERS CREEK 225 SITE BOUNDARY 0.68 miles SE 245 BOAT LANDING 4.01 miles NNW CAROWINDS 226 SITE BOUNDARY 0.48 miles S

246 SI GUARD HOUSE 7.87 miles ENE 227 SITE BOUNDARY 0.52 miles WSW 247 C FORT MILL 7.33 miles ESE PIEDMONT 228 SITE BOUNDARY 0.61 miles W

248 SI MEDICAL CENTER 6.54 miles S

YORK COUNTY 229 SITE BOUNDARY 0.84 miles NW 249 SI OPERATIONS CENTER 7.17 miles S

RIVER HILLS YORK 230 COMMUNITY CHURCH 4.37 miles N

250 SI DUKE POWER OFFICE 10.4 miles WSW RIVER HILLS 231 FRONT ENTRANCE 4.21 miles NNE 251 C CLOVER 9.72 miles WNW 232 PLEASANT HILL ROAD 4.18 miles NE 255 SITE BOUNDARY 0.61 miles ENE ZOAR ROAD AND 233 THOMAS DRIVE 3.95 miles ENE 256 SITE BOUNDARY 0.58 miles SSE 258 FAIRHOPE ROAD 9.84 miles W

C = Control SI = Special Interest

  • GPS data reflect approximate accuracy to within 2-5 meters. GPS field measurements were taken as close as possible to the item of interest.

Section 6 - Page 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 TABLE 6.0-3 Catawba 2009 Land Use Census Results*

Land Use Census performed 7/15, 7/16/2009 Sector Distance Sector

,N eDistanice Nearest Residence 0.63 Nearest Residence 0.63

<N Nearest Garden (irrigated) 1.55 S

Nearest Garden 0.80 Nearest Milk Animal,

Nearest Milk Animal Nearest Residence 0.66 Nearest Residence 0.81 NNE Nearest Garden 4.39 ssw Nearest Garden 1.02 Nearest Milk Animal Nearest Milk Animal Nearest Residence 0.56 Nearest Residence 0.66 NE Nearest Garden 0.68 S

Nearest Garden 2.29 Nearest Milk Animal Nearest Milk Animal Nearest Residence 0.61 Nearest Residence 0.61 ENE Nearest Garden (irrigated) 0.61 WSW Nearest Garden 1.10 Nearest Milk Animal Nearest Milk Animal Nearest Residence 0.65 Nearest Residence 0.68 E

Nearest Garden 3.51 W

Nearest Garden 0.96 Nearest Milk Animal Nearest Milk Animal Nearest Residence 0.84 Nearest Residence 1.10 ESE Nearest Garden 3.70 Nearest Garden 1.87 Nearest Milk Animal-Nearest Milk Animal Nearest Residence 0.97

j Nearest Residence 1.39

'SE Nearest Garden (irrigated) 2.55 NW Nearest Garden 1.54 Nearest Milk Animal Nearest Milk Animal Nearest Residence 0.74 Nearest Residence 0.91 S

Nearest Garden 1.64 NNW Nearest Garden 221 Nearest Milk Animal Nearest Milk Animal 2

"-" indicates no occurrences within the 5 mile radius

  • The land use census identifies nearest pathways to the exclusion area boundary (EAB, - 0.5 mile) for each of the 16 sectors. Locations beyond the nearest pathway for each sector are assumed to contain that pathway for dose calculation purposes. For the 4.5-5.0 mile sector all pathways, i.e., residence, garden, milk animal (goat), and meat animal (cow), are assumed to exist for dose calculation purposes.
    • GPS data reflect approximate accuracy to within 2-5 meters. GPS field measurements were taken as close as possible to the item of interest.

Section 6 - Page 4

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 Figure 6.0-1 Sampling Locations Map (Site Boundary)

Section 6 - Page 5

January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

Figure 6.0-2 Sampling Locations Map (Ten Mile Radius)

I.

Catawba Nuclear Station Sampling Locations: Map (Ten Mile Radius)

Legend TLD Locations A

All Other Locations

/

Public Roads Rail Roads

,"*°/

County Boundary I Incorporated Areas Water Approximate location of features shown N

w

  • 0 1 2

3 Po n N

Miles.

Projection NCSP NAD27 Section 6 - Page 6

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 Figure 6.0-3 CNS 2009 Land Use Census Map Section 6 - Page 7

Catawba Nuclear Station January, 2010 Offsite Dose Calculation Manual (ODCM)

Revision 52 6.0.3 CATAWBA METEOROLOGY: RELATIVE AIR CONCENTRATIONS AND DEPOSITION Calculations of annually averaged air concentrations and deposition values from routine releases provide the air dispersion and deposition factors needed for dose assessment.

The methodology is based upon Regulatory Guide 1.111, as implemented by the NRC's computer model "XOQDOQ: Computer Program for the Meteorological Evaluation of Routine Effluent Releases at Nuclear Power Stations," NUREG/CR-2919, PNL-4380, September 1982. The calculation is documented in CNC-1 108.01-00-0002 "Annual Air Dispersion and Deposition Factors for Routine Releases (ODCM)."

Five years of hourly meteorological data from the onsite instruments are processed into a representative joint frequency distribution of winds and atmospheric stability for input into the XOQDOQ model (Version 2.0). Thus, the air dispersion and deposition factors (X/Q and D/Q) output by the model are based on a five-year climatology for the site.

6.0.3.1 XOODOO METHODOLOGY AND ASSUMPTIONS A continuous, routine release (non-purge) is simulated from each unit vent. The release type is treated as "ground-level" in the model, for which surrounding terrain elevations are not input. The locale does consist of gently rolling to flat terrain, so the default open terrain recirculation factor is applied in XOQDOQ [KOPT(8)=I]. This correction factor is recommended in RG 1.111 to adjust the straight-line airflow of the model for spatial and temporal variations that are produced by large-scale weather patterns.

In order for XOQDOQ to treat the plume as a ground-level release, the exit velocity and the inside diameter of the unit vent must be input as zero. The heat emission rate of each vent is also assumed to be zero, as recommended by the model. The height of the vent (38 m) above plant grade elevation (594 ft msl) is then used to determine the plume centerline height. Using the building height (41 m) and minimum cross-sectional area of the containment building (1616 m 2), XOQDOQ applies a building wake correction to the relative air concentrations from the ground level release.

)

Calculations of relative air concentrations and deposition are made for gridded receptor distances per directional sector. The model's default values for half-lives are used (i.e. no decay; 2.26 days for short-lived noble gases;,.and 8 days with depletion factors for all iodines [DECAYS(I)= 101; 2.26; -8.0]);

6.0.3.2 METEOROLOGICAL DATA Five years (1988-1992) of hourly, onsite meteorological data are used to produce the joint frequency distributions of wind speed and direction per stability class. The 10 m level winds are used. It is these joint frequency distributions which are input to the XOQDOQ model. Hours of calm winds are distributed by direction with the same frequency as the lowest "noncalm" wind speed class [KOPT(1)=I].

Thus, wind speed classes are established so that the lowest wind speed class is the starting threshold of the anemometer Section 6 - Page 8

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 (i.e. the "calm" wind speed class). The largest wind speed class has the upper bound of (5 m/s + max hourly wind speed).

Stability classes (A-G) are based on the vertical temperature gradient, measured by the hourly averaged delta-T variable.

6.0.3.3 ANNUAL XOODOO COMPARISON TO THE ODCM Each year, the prevailing winds and stability class frequencies for CNS are compared to the 5-year period (1988-1992) upon which the x,/Q and D/Q calculations have been made.

The 5-year climatology is summarized in Table 6.0-4 and Table 6.0-5 below. Since the comparison is being made to a 5-year climatology, significant differences should not occur in the meteorological variables of concern (i.e. winds and delta-T).

The meteorological comparison serves to verify this assumption.

Table 6.0-4 CNS Atmospheric Stability Frequency (1988-1992)

A

ýýB I C I

E FI -

GI IFrequencyI

(%)

10.9 4.3 5.5 31.1 26.9 10.3 10.9 Table 6.0-5 CNS Frequency of Wind Direction (From) and Speed (1988-1992)

Wind Direction Wind -Speed.

Wind Speed Sector Frequency (%)

Class (r/s Frequency (%)

N 10.1 CALM 0.9 NNE 8.6 0.45 - 0.74 m/s 3.6 NE 4.9 0.75 - 0.99 m/s 4.7 ENE 1.9 1.00 - 1.24 m/s 6.3 E

-1 1.25 - 1.49 m/s 9.7 ESE 1.4 1.50 - 1.99 m/s 17.5 SE 2.9 2.00 - 2.99 m/s 25.1 SSE 6.2 3.00 - 3.99 m/s 16.4 S

11.1 4.00 - 4.99 m/s 9.4 SSW 13.7 5.00 - 5.99 m/s 3.5 SW 9.6 6.00 - 7.99 m/s 1.6 WSW 5.2 8.00 - 9.99 m/s 0.1 W

4.1

> 9.99 m/s 1.9 WNW 4.8 NW 4.8 NNW 8.9 The joint frequency distributions of wind speed and direction versus atmospheric stability class are also determined from the annual data. to provide input to the XOQDOQ model.

Section 6 - Page 9

,J Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 Modeled z/Q and D/Q values for the 0.5 mile Exclusion Area Boundary at CNS are compared to the maximum of the (1988-1992) X/Q and D/Q values from all sectors.

If the newly calculated annual dispersion and deposition values do not result in a significant increase in the calculated offsite dose relative to the IOCFR50, Appendix I dose objectives then the 5-year x/Q and D/Q values used in the Annual Radiological Effluent Release Report (ARERR) are not revised. An increase in calculated offsite dose that is greater than five percent of the 10CFR50, Appendix I dose objectives would be considered significant enough to warrant a change iii the X/Q and D/Q values used in the ARERR. If an increasing trend in the annual X/Q and D/Q values compared to the 5-year values is noted then~a revised set of 5-year X/Q and D/Q values will be generated. These limiting values are listed in Table 6.0-6. The entire X/Q and D/Q list based on directional sector and distance is given in Table 6.0-8 and 6.0-9.

Table 6.0-6 CNS Limiting X/Q and D/Q Values (1988-1992)

(xQO/I~'

Distanfce

'Sect'o Maximum X/Q 3.5 1OE-5 0.5 mile EAB NNE Maximum D/Q 1.078E-7 0.5 mile EAB NNE Note:

The Catawba meteorological instruments were moved from the 40 m microwave tower to a new 60 m meteorological tower in June 1996. The taller tower became operational at 1900 hours0.022 days <br />0.528 hours <br />0.00314 weeks <br />7.2295e-4 months <br /> on June 11, 1996. Therefore, determination of atmospheric stability prior to this time uses the 30 m separation criteria shown in Table 6.0-7; while data after this time uses the 50.9 m separation criteria.

Table 6.0-7 CNS Delta-T Ranges per Vertical Separation Distances Stability 30,m separation Delta-T.*

50.9 inseparation Delta-T Class

'(between 40m-10m levels)

(betwieen 60.2mn,9;3m levels)

'Starting at 1900 hours0.022 days <br />0.528 hours <br />0.00314 weeks <br />7.2295e-4 months <br /> on June 1, 1996.

A dT< -0.57 dT < -0.97 B

-0.57 < dT < -0.51

-0.97 < dT < -0.87 C

-0.51 < dT < -0.45

-0.87 < dT < -0.76 D

-0.45 < dT < -0.15

-0.76 < dT < -0.25 E

-0.15 <dT < 0.45

-0.25 < dT < 0.76 F

0.45 < dT < 1.2 0.76 < dT < 2.04 G

1.2 < dT 2.04 < dT Section 6 - Page 10

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 Table 6.0-8 Catawba x/Q Average Values (1988-1992)

(sec/m 3)

Sector 0.5,1.0*

1.0-1.5 1.5-2.01 2.0*-25

'2.5-3.0 3.0-3.5 3.5-4.0 1 4.0-4.5 4.5-5.0 N

2.959E-05 7.879E-06 3.222E-06 1.768E-06 1.133E-06 7.978E-07 5.987E-07 4.701E-07 3.818E-07 NNE 3.510E-05 9.342E-06 3.814E-06 2.091E-06 1.338E-06 9.420E-07 7.066E-07 5.546E-07 4.503E-07 NE 2.927E-05 7.738E-06 3.166E-06 1.738E-06 1.114E-06 7.848E-07 5.891E-07 4.627E-07 3.359E-07 ENE 2.208E-05 5.813E-06 2.406E-06 1.330E-06 8.573E-07 6.065E-07 4.568E-07 3.598E-07 2.931E-07 E

1.858E-05 4.895E-06 2.032E-06 1.126E-06 7.266E-07 5.147E-07 3.880E-07 3.059E-07 2.493E-07 ESE 1.962E-05 5,223E-06 2.163E-06 1.197E-06 7.712E-07 5.457E-07 4.110E-07 3.238E-07 2.637E-07 SE 1.965E-05 5.167E-06 2.151E-06 1.194E-06 7.717E-'07 5.471E-07 4.128E-07 3.257E-07 2,656E-07 SSE 2.561E-05 6.751E-06 2.798E-06 1.548E-06 9.982E-07 7.064E-07 5.323E-07 4.194E-07 3.416E-07 S

1.552E-05 4.101E-06 1.642E-06 8.878E-07 5.624E-07 3.926E-07 2.924E-07 2.282E-07 1.843E-07 SSW 8.747E-06 2.267E-06 8.761E-07 4.621E-07 2.872E-07 1.973E-07 1.450E-07 1.118E-07 8.939E-08 SW 5.071E-06 1.328E-06 5.087E-07 2.666E-07 1.648E-07 1.127E-07 8.249E-08 6.340E-08 5.052E-08 WSW 3 265E-06 8.730E-07 3.413E-07 1.815E-07 1.135E-07 7.839E-08 5.786E-08 4.479E-08 3.592E-08 W

2.024E-06 5.307E-07 2.058E-07 1.088E-07 6.771E-08 4.657E-08 3.426E-08 2.644E-08

2. 15E-08 "WN 3.468E-06 9.193E-07 3.595E-07 1.913E-07 1.197E-07 8.267E-08 6.104E-08 4.727E-08 3.793E-08 NW 6.249E-06 1.680E-06 6.638E-07 3.558E-07 2.239E-07 1.555E-07 1.153E-07 8.959E-08 7.212E-08 NNW 1.406E-05 3.723E-06 1.508E-06 8.221E-07 5.242E-07 3.678E-07 2.752E-07 2.155E-07 1.747E-07
  • Units are in miles from the station. Each X/Q value is calculated at the closest location for the sector, e.g., 2.959E-05 sec/m 3 is the x/Q value at 0.5 miles (N) from the station.

As discussed in Catawba UFSAR Section 2.1.1.3, the boundary for establishing gaseous effluent release limits is the exclusion area boundary (EAB). The EAB is defined as a 2500-ft. (-0.5 mile) radius from the station center.

Section 6 - Page 11

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010, Revision 52 Table 6.0-9 Catawba D/Q Average Values (1988-1992)

(m-2)

Sector 0.5-1.V" 1.0-1.5 1.5 2.02.5 2.5-13.0 3.0-3.5,

-4.0, 4,0 4.5 4.5 5.0 N

8.799E-08 2.148E-08 7.715E-09 3.826E-09 2.253E-09 1.475E-09 1.038E-09 7.693E-10 5.928E-10 NNE 1.078E-07 2.630E-08 9.448E-09 4.686E-09 2.759E-09 1.807E-09 1.271E-09 9.421E-10 7.260E-10 NE 7.653E-08 1.868E-08 6.710E-09 3.328E-09 1.960E-09 1.283E-09 9.028E-10 6.691E-10 5.156E-10 ENE 4.135E-08 1.009E-08 3.626E-09 1.798E-09 1.059E-09' 6.933E-10 4.878E-10 3.615E-10 2.786E-10 E

3.246E-08 7.924E-09 2.846E-09 1.411E-09 8.311E-10 5.442E-10 3.829E-10 2.838E-10 2.187E-10 ESE 3.810E-08

,9.301E-09 3.341E-09 1.657E-09 9.755E-10 6.388E-10 4.495E-10 3.331E-10 2.567E-10 SE 3.799E-08 9.274E-09 3.331E-09 1.652E-09 9.727E-10 6.369E-10 4.482E-10 3.321E-10 2.560E-10 SSE 7.019E-08 1.713E-08 6.154E-09 3.052E-09 1.797E-09 1.177E-09 8.280E-10 6.136E-10 4.729E-10 S

7.881E-08 1.924E-08 6.910E-09 3.427E-09 2.018E-09 1.321E-09 9.297E-10 6.890E-10 5.310E-10 SSW 6.787E-08 1.657E-08 5.951E-09 2.951E-09

.1.738E-09 1.138E-09 8.007E-10 5.934E-10 4.573E-10 SW 3.877E-08 9.464E-09 3.399E-09 1.686E-09 9.926E-10 6.500E-10 4.573E-10 3.389E-10 2.612E-10 WSW 1.476E-08 3.604E-09 1.295E-09 6.420E-10 3.780E-10 2.475E-10 1.742E-10 1.291E-10 9.947E-11 W

7.895E-09 1.927E-09 6.922E-10 3.433E-10 2.021E-10 1.324E-10 9.313E-11 6.902E-11 5.319E-11 WNW 1.087E-08 2.654E-09 9.534E-10 4.728E-10 2.784E-10 1.823E-10 1.283E-10 9.507E-11 7.326E-11 NW 2.319E-08 5.661E-09 2.033E-09 1.008E-09 5.938E-10 3.888E-10 2.736E-10 2.027E-10 1.562E-10 NNW 4.863E-08 1.187E-08 4.264E-09 2.114E-09 1.245E-09 8.152E-10 5.736E-10 4.251E-10 3.276E-10

  • Units are in miles from the station. Each D/Q value is calculated at the closest location for the sector, e.g., 8.799E-08 m2 is the D/Q value at 0.5 miles (N) from the station.

As discussed in Catawba UFSAR Section 2.1.1.3, the boundary for establishing gaseous effluent release limits is the exclusion area boundary (EAB). The EAB is' defined as a 2500-ft. (-0.5 mile) radius from the station center.

Section 6 - Page 12

Catawba Nuclear Station January, 2010 Offsite Dose Calculation Manual (ODCM)

Revision 52 7.0 LICENSEE INITIATED CHANGES All changes made to the Catawba ODCM are reviewed by knowledgeable individual(s), and approved by the Station Manager 'and the General Office Radiation Protection Manager prior to implementation. The following changes do not adversely impact the accuracy or reliability of effluent, dose, or setpoint calculations.

Executive Summary - Page 1 Added Technical Specifications (TSs) and Selected Licensee Commitments (SLCs) references for the dose rate and dose limitation values listed in the Executive Summary.

Section 1 - Pages 1 and 2 Liquid radwaste system descriptions contained in (A) through (F) were modified to more accurately reflect current liquid radwaste system processes.

Section 1 - Page 6 Figure 1.0-2 was revised to remove iodine monitors EMF37 (unit vent) and EMF40 (containment) from the drawing. For the unit vent, a continuous unit vent iodine sample is pulled, and the charcoal filter cartridge is changed out weekly and counted. For containment releases a grab sample cartridge is used to measure iodine for each release. (Ref. C-09-03308)

Section 2 - Page 2 Revised sentence "At this time the discharge may be routed to the floor drain tank for processing or routed directly to the RL/RN discharge point rather than through WC" to "At this time the discharge may be routed to WL for processing rather than through WC" to more accurately reflect current liquid radwaste system processes.

Section 2 - Page 5 In last sentence of first paragraph changed the word "contains" to "has" for clarification purposes.

Corrected typographical error in last sentence on page 5 by removing the comma between the word "vent" and "and".

Section 2 - Page 7 Changed format of 4.72E+02 to 472 and 6.OE+01 to 60 to reduce potential confusion with the spacing in the exponential format.

Section 2 2 Page 8 Figure 2.0-3 was revised to remove iodine monitors EMF37 (unit vent) and EMF40 (containment) from the drawing. For the unit vent, a continuous unit vent iodine sample is pulled, and the charcoal filter cartridge is changed out weekly and counted. For containment releases a grab sample cartridge is used to measure iodine for each release. (Ref. C-09-03308)

Section 7 - Page 1

Catawba Nuclear Station January, 2010 Offsite Dose Calculation Manual (ODCM)

Revision 52 Section 3 - Page 2 Additional information was added to the definition of the Cs-137 equivalence factor for clarification and to be consistent with the McGuire and Oconee ODCMs. The following statement was added: "This factor includes a 4-hour decay time due to the average time between sample and release."

Section 3 - Pages 6 and 7 Changed format of 4.72E+02 to 472 to reduce potential confusion with the spacing in the exponential format.

Section 3 - Page 9 Substituted symbol, "-", for the word "approximately" in two places. This change allowed a space to be added before the "Expected cpm" equation.

Section 3 - Page 9 (cont.)

Changed "2.6E4" to "2.6E+04" to be consistent with exponential format in the rest of the ODCM.

Section 4 - Page 3 Changed the dilution factor from the near field area to the potable water intake from "217" to "10". More conservatism was added to this dilution factor to ensure that the potable water pathway dose model is conservative enough to account for deviations from average water flow in a particular year. Environmental water samples indicated that using a "21.7" value in the dose model does not always envelope the potable water dose pathway using actual environmental water sample activity concentrations.

Section 4 - Page 18 Changed the schedule estimate for Phase 1 initial ISFSI cask loading from completion in October 2009 to completion by the end of 2011.

Changed "Annual Effluent Release Report" to "Annual Radiological Effluent Release Report".

Section 5 - Page 1 In the paragraph defining the term "uranium fuel cycle" changed the word "or" to "of' to correct typographical error.

Section 6 - Page 4 Changed title of Table 6.0-3 to: "Catawba 2009 Land Use Census Results."

Land use census dates were changed to reflect 2009 census dates. The 2009 land use census was performed July 15-16, 2009, and the results were certified and made available for use on November 2, 2009.

Section 7-Page 2

Catawba Nuclear Station January, 2010 Offsite Dose Calculation Manual (ODCM)

Revision 52 Section 6 - Page 4 (cont.)

The distance (miles) for the NNW sector residence was changed from 1.00 to 0.91.

The distance (miles) for the NE sector garden was changed from 4.24 to 0.68.

The distance (miles) for the ESE sector garden was changed from 3.72 to 3.70.

The distance (miles) for the SW sector garden was changed from 2.55 to 2.29.

The distance (miles) for the WSW sector garden was changed from 2.04 to 1.10.

The distance (miles) for the WNW sector garden was changed from 1.47 to 1.87.

Section 6 - Page 5 Figure 6.0-1 was regenerated with higher resolution.

Section 6 - Page 6 Figure 6.0-2 was regenerated with higher resolution.

Section 6 - Page 7 Changed title of Figure 6.0-3 to "CNS 2009 Land Use Census Map."

Figure 6.0-3 was regenerated to depict 2009 census data and with higher resolution.

Section 6 - Page 9 Unbolded bolded data in Table 6.0-4 and Table 6.0-5 to make the data font in the tables consistent.

Section 7 - Page 3

0 January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX A Dose Factors for Exposure to a Semi-Infinite Cloud of Noble Gases*

Ki, l

,i N

Nuclide Total-BodY Skin Gamma Air.,

Beta Air

  • mrer/yr/

mremlyr/f mrad/yr/

j mrad/yr/

Ci/m 3 mCi/M 3

pCi/mr 3

__Ci/m3 AR-41 8.840E+03 2.690E+03 9.300E+03 3.280E+03 KR-83M 7.560E-02 0.OOOE+00 1.930E+01 2.880E+02 KR-85M 1.170E+03 1.460E+03 1.230E+03-1.970E+03 KR-85 1.610E+01 1.340E+03 1.720E+01 1.950E+03 KR-87 5.920E+03 9.730E+03 6.170E+03 1.030E+04 KR-88 1.470E+04 2.370E+03 1.520E+04 2.930E4-03 KR-89 1.660E+04 1.010E+04 1.730E+04 1.060E+04 KR-90 1.560E+04 7.290E+03 1.630E+04 7.830E+03 XE-131M 9.150E+01 4.760E+02 1.560E+02 1.11 OE+03 XE-133 M 2.510E+02 9.940E+02 3.270E+02 1.480E+03 XE-133 2.940E+02 3.060E+02 3.530E+02 1.050E+03 XE-135M 3.120E+03 7.110E+02 3.360E+03 7.390E+02 XE-135 1.810E+03 1.860E+03 1.920E+03 2.460E+03 XE-137 1.420E+03 1.220E+04 1.510E+03 1.270E+04 XE-138 8.830E+03 4.130E+03 9.210E+03 4.750E+03

    • Reference Regulatory Guide 1.109, Table B-1 Appendix A - Dose Factors for Exposure to a Semi-Infinite Cloud of Noble Gases - Page 1 of I

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX B P. fnagp VFkptare fnr 1111Q, in ti-p PAuganuu Dgi1tgg 1 Tfgimit-Cale"Intinne I

~

ASS *SS

~

U ~

'S'~~

St

5.4 Agegroup

CHILD Pathway:

Inhalation (INHL)

Units':',

mrem/yr / ýtCi/m 3 Nuclide Bone Liver Thyroid Kidney Lung Gilli Skin Total Body H-3 0.000E+00 1.120E+03 1.120E+03 1.120E+03 1.120E+03 1.120E+03 0.OOOE+00 1.120E+03 C-14 3.590E+04 6.730E+03 6.730E+03 6.730E+03 6.730E+03 6.730E+03 0.OOOE+00 6.730E+03 NA-24 1.610E+04 1.610E+04 1.610E+04 1.610E+04 1.610E+04 1.610E+04 0.OOOE+00 1.610E+04 P-32 2.600E+06 1.140E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.220E+04 0.OOOE+00 9.880E+04 CR-51 0.OOOE+00 0.000E+00 8.550E+01 2.430E+01 1.700E+04 1.080E+03 0.OOOE+00 1.540E+02 MN-54 0.OOOE+00 4.290E+04 0.000E+00 1.000E+04 1.580E+06 2.290E+04 O.OOOE+00 9.510E+03 MN-56 0.OOOE+00 1.660E+00 0.OOOE+00 1.670E+00 1.310E+04 1.230E+05 0.OOOE+00 3.120E-01 FE-55 4.740E+04 2.520E+04 0.OOOE+00 0.OOOE+00 1.11OE+05 2.870E+03 0.OOOE+00 7.770E+03 FE-59 2.070E+04 3.340E+04 0.OOOE+00 0.OOOE+00 1.270E+06 7.070E+04 0.OOOE+00 1.670E+04 CO-58 0.OOOE+00 1.770E+03 0.OOOE+00 0.OOOE+00 1.11OE+06 3.440E+04 0.OOOE+00 3.160E+03 CO-60 0.OOOE+00 1.310E+04 0.OOOE+00 0.OOOE+00 7.070E+06 9.620E+04 0.OOOE+00 2.260E+04 NI-63 8.210E+05 4.620E+04 0.OOOE+00 0.OOOE+00 2.750E+05 6.330E+03 0.OOOE+00 2.800E+04 NI-65 2.990E+00 2.960E-01 0.OOOE+00 0.OOOE+00 8.180E+03 8.400E+04 0.OOOE+00 1.640E-01 CU-64 0.000E+00 1.990E+00 0.OOOE+00 6.030E+00 9.580E+03 3.670E+04 0.OOOE+00 1.070E+00 ZN-65 4.260E+04 1.130E+05 0.OOOE+00 7.140E+04 9.950E+05 1.630E+04 0.000E+00 7.030E+04 ZN-69 6.700E-02 9.660E-02 0.OOOE+00 5.850E-02 1.420E+03 1.020E+04 0.OOOE+00 8.920E-03 BR-83 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 0.000E+00 4.740E+02 BR-84 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.480E+02 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.530E+01 RB-86 0.OOOE+00 1.980E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 7.990E+03 0.OOOE+00 1.140E+05 RB-88 0.OOOE+00 5.620E+02

.0.000E+00 0.OOOE+00 0.OOOE+00 1.720E+01 0.OOOE+00 3.660E+02 RB-89 0.OOOE+00 3:450E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.890E+00 0.OOOE+00 2.900E+02 SR-89 5.990E+05 0.000E+00 0.000E+00 0.OOOE+00 2.160E+06 1.670E+05 0.OOOE+00 1.720E+04 SR-90 1.010E+08 0.OOOE+00 0.000E+00 0.OOOE+00 1.480E+07 3.430E+05 0.OOOE+00 6.440E+06 SR-91 1.210E+02 0.OOOE+00 0.OOOE+00 0.000E+00 5.330E+04 1.740E+05 0.OOOE+00 4.590E+00 Appendix B Pi Child Inhalation - Page 1 of 3 0

0 0

January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX B Pi Dose Factors for use in the Gaseous Release Rate Limit Calculations Agegroup:

CHILD Pathway:

Inhalation (INHL)

Units:

mrem/yr /WCi/m 3

Nuclide Bone.

-Liver

.m.-Thy*roid.,

Kidney Lung Gilli Skin Total Body" SR-92 1.310E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.400E+04 2.420E+05 0.OOOE+00 5.250E-01 Y-90 4.11OE+03 0.OOOE+00 0.OOOE+/-00 0.OOOE+00 2.620E+05 2.680E+05 0.OOOE+00 1.11OE+02 Y-91 9.i40E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.630E+06 1.840E+05 0.OOOE+00 2.440E+04 Y-91M 5.070E-01 0.OOOE+00 0.000E+/-00, 0.OOOE+00 2.810E+03 1.720E+03 0.OOOE+00 1.840E-02 Y-92 2.030E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.390E+04 2.390E+05 0.OOOE+00 5.810E-01 Y-93 1.860E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 7.440E+04 3.880E+05 0.OOOE+00 5.11OE+00 ZR-95 1.900E+05 4.180E+04 0.OOOE+00 5.960E+04 2.230E+06 6.1 10E+04 0.OOOE+00 3.700E+04 ZR-97 1.880E+02 2.720E+01 0.000E+00 3.880E-01 1.130E+05 3.510E+05 0.OOOE+00 1.600E+01 NB-95 2.350E+04 9.180E+03 0.OOOE+00 8.620E+03 6.140E+05 3.700E+04 0.OOOE+00 6.550E+03 MO-99 0.OOOE+00 1.720E+02 0.OOOE+00 3.920E+02 1.350E+05 1.270E+05 0.OOOE+00 4.260E+01 TC-99M 1.780E-03 3.480E-03 0.OOOE+00 5.070E-02 9.510E+02 4.810E+03 0.OOOE+00 5.770E-02 TC-101 8.100E-05 8.510E-05 0.OOOE+00 1.450E-03 5.850E+02 1.630E+01 0.OOOE+00 1.080E-03 RU-103 2.790E+03 0.OOOE+00 0.OOOE+00 7.030E+03 6.620E+05 4.480E+04 0.OOOE+00 1.070E+03 RU-105 1.530E+00 0.OOOE+00 0.OOOE+00 1.340E+00 1.590E+04 9.950E+04 0.OOOE+00 5.550E-01 RU-106 1.360E+05 0.OOOE+00 0.OOOE+00 1.840E+05 1.430E+07 4.290E+05 0.OOOE+00 1.690E+04 AG-110M 1.690E+04 1.140E+04 0.OOOE+00 2.120E+04 5.480E+06 1.000E+05 0.OOOE+00 9.140E+03 TE-125M 6.730E+03 2.330E+03 1.920E+03 0.OOOE+00 4.770E+05 3.380E+04 0.OOOE+00 9.140E+02 TE-127 2.770E+00 9.510E-01 1.960E+00 7.070E+00 1.000E+04 5.620E+04 0.OOOE+00 6.100E-01 TE-127M 2.490E+04 8.550E+03 6.070E+03 6.360E+04 1.480E+06 7.140E+04 0.OOOE+00 3.020E+03 TE-129 9.770E-02 3.500E-02 7.140E-02 2.570E-01 2.930E+03 2.550E+04 0.OOOE+00 2.380E-02 TE-129M 1.920E+04 6.840E+03 6.330E+03 5.030E+04 1.760E+06 1.820E+05 0.OOOE+00 3.040E+03 TE-131 2.170E-02 8.440E-03 1.700E-02 5.880E-02 2.050E+03 1.330E+03 0.OOOE+00 6.590E-03 TE-131M 1.340E+02 5.920E+01 9.770E+01 4.OOOE+02 2.060E+05 3.080E+05 0.OOOE+00 5.070E+01 TE-132 4.81 OE+02 2.720E+02 3.170E+02 1.770E+03 3.770E+05 1.380E+05 0.OOOE+00 2.630E+02 11-130 8.180E+03 1.640E+04 1.850E+06 2.450E+04 0.OOOE+00 5.11OE+03 0.OOOE+00 8.440E+03 Appendix B Pi Child Inhalation - Page 2 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX B Pi Dose Factors for use in the Gaseous Release Rate Limit Calculations Agegroup:

CHILD Pathwway:

Inhalation (INHL)

Units:

mrem/yr / jiCi/m 3 Nuclide Bofie Liver

-. Thy'roid

.'Kidney Lung Gilli.

Skin Total Body 1-131 4.810E+04 4.810E+04 1.620E+07 7.880E+04 0.000E+00 2.840E+03 0.OOOE+00 2.730E+04 1-132 2.120E+03 4.070E+03 1.940E+05 6.250E+03 0.000E+00 3.200E+03 0.OOOE+00 1.880E+03 1-133 1.660E+04 2.030E+04 3.850E+06 3.380E+04 0.OOOE+00 5.480E+03 0.OOOE+00 7.700E+03 1-134 1.170E+03 2.160E+03 5.070E+04 3.300E+03 0.OOOE+00 9.550E+02 0.OOOE+00 9.950E+02 1-135 4.920E+03 8.730E+03 7.920E+05 1.340E+04 0.000E+00 4.440E+03 0.OOOE+00 4.140E+03 CS-134 6.510E+05 1.010E+06 0.OOOE+00 3.300E+05 1.210E+05 3.850E+03 0.OOOE+00 2.250E+05 CS-136 6.510E+04 1.710E+05 0.OOOE+00 9.550E+04 1.450E+04 4.180E+03 0.OOOE+00 1.160E+05 CS-137 9.060E+05 8.250E+05 0.OOOE+00 2.820E+05 1.040E+05 3.620E+03 0.OOOE+00 1.280E+05 CS-138 6.330E+02 8.400E+02 0.OOOE+00 6.220E+02 6.81 OE+0 1 2.700E+02 0.OOOE+00 5.550E+02 BA-139 1.840E+00 9.840E-04 0.OOOE+00 8.620E-04 5.770E+03 5.770E+04 0.000E+00 5.360E-02 BA-140 7.400E+04 6.480E+01 0.OOOE+00 2.110E+01 1,740E+06 1.020E+05 0.OOOE+00 4.330E+03 BA-141 1.960E-01 1.090E-04 0.OOOE+00.

9.470E-05 2.920E+03 2.750E+02 0.OOOE+00 6.360E-03 BA-142 5.000E-02 3.600E-05 0.OOOE+00 2.910E-05 1.640E+03 2.740E+00 0.OOOE+00 2.790E-03 LA-140 6.440E+02 2.250E+02 0.OOOE+00 0.OOOE+00 1.830E+05 2.260E+05 0.OOOE+00 7.550E+01 LA-142 1.300E+00 4.110E-01 0.OOOE+00 0.OOOE+00 8.700E+03 7.580E+04 0.OOOE+00 1.290E-01 CE-141 3.920E+04 1.950E+04 0.OOOE+00 8.550E+03 5.440E+05 5.660E+04 0.OOOE+00 2.900E+03 CE-143 3.660E+02 1.990E+02 0.OOOE+00 8.360E+01 1.150E+05 1.270E+05 0.OOOE+00 2.870E+01 CE-144 6.770E+06 2.120E+06 0.OOOE+00 1.170E+06 1.200E+07 3.880E+05 6.000E+00 3.610E+05 PR-143 1.850E+04 5.550E+03 0.OOOE+00 3.OOOE+03 4.330E+05 9.730E+04 0.OOOE+00 9.140E+02 PR-144 5.960E-02 1.850E-02 0.OOOE+00 9.770E-03 1.570E+03 1.970E+02 0.OOOE+00 3.000E-03 ND-147 1.080E+04 8.730E+03 0.OOOE+00 4.810E+03 3.280E+05 8.210E+04 0.OOOE+00 6.810E+02 W-187 1.630E+01 9.660E+00 0.OOOE+00 0.OOOE+00 4.110E+04

9. 1OOE+04 0.OOOE+00 4.330E+00 NP-239 4.660E+02 3.340E+01 0.OOOE+00 9.730E+01 5.810E+04 6.400E+04 0.OOOE+00 2.350E+01 Appendix B Pi Child Inhalation - Page 3 of 3

January, 20 10 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX C Ai Adult Dose Factors for use in the Liquid Dose Calculations Agegroup:

ADULT Pathway:

Potable Water (PWtr)

'Units:

mrem/hr / gxCi/ml

~Niilide

~ Bn.'

LiverK Thyroid

~Kidneyp

>Lunig 7:

Gilli Ski T'Iotal[ Body.-,-

HL3 0.OOOE+00 8.740E+00 8.740E+00 8.740E+00 8.740E+00 8.740E+00 0.OOOE+00 8.740E+00 C-14 2.360E+02 4.730E+01 4.730E+01 4.730E+01 4.730E+01 4.730E+01 0.000E+00 4.730E+01 NA-24 8.140E+01 8.140E+01 8.140E+01 8.140E+01 8.140E+01 8.140E+01 0.000E+00 8.140E+01 P-32 1.570E+04 9.750E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.760E+03 0.OOOE+00 6.060E+02 CR-51 0.OOOE+00 0.OOOE+00 1.310E-01 4.820E-02 2.900E-01 5.500E+01 0.OOOE+00 2.190E-01 MN-54 0.OOOE+00 3.800E+02 0.OOOE+00 1.130E+02 0.OOOE+00 1.160E+03 0.OOOE+00 7.250E+01 MN-56 0.OOOE+00 3.800E-01 0.OOOE+00 4.820E-01 0.OOOE+00 1.210E+01 0.000E+00 6.740E-02 FE-55 2.290E+02 1.580E+02 0.OOOE+00 0.OOOE+00 8.820E+01 9.070E+01 0.OOOE+00 3.690E+01 FE-59 3.580E+02 8.420E+02 0.OOOE+00 0.OOOE+00 2.350E+02 2.810E+03 0.0.00E+00 3.230E+02 CO-58 0.OOOE+00 6.170E+01.

0.OOOE+00 0.OOOE+00 0.000E+00 1.250E+03 0.OOOE+00 1.380E+02 CO-60 0.OOOE+00 1.780E+02 0.OOOE+00 0.OOOE+00 O.OOOE+00 3.340E+03 0.OOOE+00 3.930E+02 NI-63 1.080E+04 7;500E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.560E+02 0.OOOE+00 3.630E+02 NI-65 1.620E+00 2.100E-01 0.OOOE+00 0.OOOE+00 O.OOOE+00 5.340E+00 0.OOOE+00 9.600E CU-64 0.OOOE+00 3.590E+00 0.OOOE+00 9.060E+00 0.OOOE+00 3.060E+02 0.OOOE+00 1.690E+00 ZN-65 4.020E+02 1.280E+03 0.OOOE+00 8.560E+02 0.OOOE+00 8.060E+02 0.OOOE+00 5.780E+02 ZN-69 1.070E-04 2.050E-04 0.OOOE+00 1.330E-04 0.OOOE+00 3.080E-05 0.OOOE+00 1.430E-05 BR-83 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.480E-01 0.OOOE+00 1.030E-01 BR-84 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.270E-12 0.OOOE+00 6;710E-07 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.380E-77 RB 0.000E+00 1.720E+03 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.400E+02 0.OOOE+00 8.030E+02 RB-88 0.OOOE+00 3.360E-12 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.640E-23 0.OOOE+00 1.780E-12 RB-89 0.OOOE+00 3.090E-14 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.790E-27 0.OOOE+00 2.170E-14 SR-89 2.550E+04 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.080E+03 0.OOOE+00 7.3 10E+02 SR-90 6.310E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.820E+04 0.OOOE+00" 1.550E+05 SR-91 1.960E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 9.350E+02 0.OOOE+00 7.930E+00 Appendix C Ai Adult Water - Page 1 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX C A. Advilf nn~c, Fauofnre fnr "ea in tho -F "inri 11n~i *lonl*finna S kt ttZt fl

.~O,

K tt~

K ~J t~S K

t~3 K SILKS K4Kt KK.K

.S tFJS,

~

K SaNta SASS KKJ Agegroup:

ADULT PathWay:

Potable Water (PWtr)

Units:

mrem/hr / ýCi/ml Nuclide Bonie '

Liver Thyro id

'kid ney

-ug Gil S

i&

'T tfAl ody SR'-92 8.290E+0o 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.640E+02 0.OOOE+00 3.590E-01 Y-90 7.030E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 7.460E+03 0.OOOE+00 1.890E-02 Y-91 1.170E+O1 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.420E+03 0.OOOE+00 3.120E-01 Y-91M 3.360E-07 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 9.860E-07 0.OOOE+00 1.300E-08 Y-92 6.710E-03 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.170E+02 0.OOOE+00 1.960E-04 Y-93 9.770E-02 0.060E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.100E+03 0.OOOE+00 2.700E-03 ZR-95 2.520E+00 8.070E-01 0.OOOE+00 1.270E+00 0.OOOE+00 2.560E+03 0.000E+00 5.460E-01 ZR-97 8.540E-02 1.720E-02 0.OOOE+00 2.600E-02 0.OOOE+/-00 5.340E+03 0.OOOE+00 7.880E-03 NB-95 5.130E-01 2.850E-01 0.OOOE+00 2.820E-01 0.OOOE+00 1.730E+03 0.OOOE+00 1.530E-01 MO-99 0.OOOE+00 3.160E+02 0.OOOE+00 7.160E+02 0.OOOE+00 7.330E+02 0.OOOE+00 6.020E+01 TC-99M 5.160E-03 1.460E-02 0.OOOE+00 2.210E-01 7.140E-03 8.630E+00 0.OOOE+00 1.860E-01 TC-101 1.130E-17 1.630E-17 0.OOOE+00 2.930E-16 8.320E-18 4.890E-29 0.OOOE+00 1.600E-16 RU-103 1.530E+01 0.OOOE+00 0.OOOE+00 5.820E+01 0.OOOE+00 1.780E+03 0.OOOE+00 6.570E+00 RU-105 1.970E-01 0.OOOE+00 0.OOOE+00 2.540E+00 0.000E+00 1.200E+02 0.OOOE+00 7.760E-02 RU-106 2.290E+02 0.OOOE+00 0.OOOE+00 4.410E+02 0.OOOE+00 1.480E+04 0.OOOE+00 2.890E+01 AG-110M 1.330E+01 1.230E+01 0.OOOE+00 2.420E+01 0.OOOE+00 5.020E+03 0.OOOE+00 7.300E+00 TE-125M 2.220E+02 8.030E+01 6.670E+01 9.020E+02 0.OOOE+00 8.850E+02 0.OOOE+00 2.970E+01 TE-127 3.780E+00 1.360E+00

-2.800E+00 1.540E+01 0.OOOE+00 2.980E+02 0.OOOE+00 8.170E-01 TE-127M 5.620E+02 2.010E+02 1.440E+02 2.280E+03 0.OOOE+00 1.880E+03 0.OOOE+00 6.840E+01 TE-129 1.920E-03 7.230E 1.480E-03 8.080E-03 0.OOOE+00 1.450E-03 0.OOOE+00 4.690E-04 TE-129M 9.470E+02 3.530E+02 3.250E+02 3.950E+03 0.OOOE+00 4.770E+03 0.OOOE+00 1.500E+02 TE-131 3.520E-09 1.470E-09 2.900E-09 1.540E-08 0.OOOE+00 4.990E-10 0.OOOE+00 1.11OE-09 TE-131M 1.090E+02 5.340E+01 8.450E+01 5.400E+02 0.OOOE+00 5.300E+03 0.OOOE+00 4.450E+01 TE-132 1.880E+02 1.220E+02 1.350E+02 1.170E+03 0.OOOE+00 5.770E+03 0.OOOE+00 1.140E+02 1-130 3.210E+01 9.460E+01 8.020E+03 1.480E+02 0.000E+00 8.140E+01 0.OOOE+00 3.730E+01 Appendix C Ai Adult Water - Page 2 of 3 I

January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX C Ai Adult Dose Factors for use in the Liquid Dose Calculations Agegroup:

ADULT Pathway:

Potable Water (PWtr) tiUnits`:,

mrem/hr / p.Ci/ml

.,',Nuclide

, Bone' Liver Thyroid

Kidne,
ung,

.Gi!!i.

skiii, 1 Total Body.

1-131 3.320E+02 4.740E+02 1.550E+05 8.130E+02 0.OOOE+00 1.250E+02 0.OOOE+00 2.720E+02 1-132 4.540E-01 1.220E+00 4.250E+01 1.940E+00 0.OOOE+00 2.280E-01 0.OOOE+00 4.250E-01 1-133 7.920E+01 1.380E+02 2.020E+04 2.400E+02 O.OOOE+00 1.240E+02 0.OOOE+00 4.200E+01 1-134 6.580E-04 1.790E-03 3.100E-02 2.840E-03 0.OOOE+00 1.560E-06 0.OOOE+00 6.390E-04 1-135 1.050E+01 2.750E+01 1.810E+03 4.400E+01 0.OOOE+00 3.100E+01 0.OOOE+00 1.010E+01 CS-134 5.170E+03 1.230E+04 0.OOOE+00 3.980E+03 1.320E+03 2.150E+02 0.OOOE+00

  • 1.010E+04 CS-136 5.280E+02 2.080E+03 0.OOOE+00 1.160E+03 1.590E+02 2.370E+02 0.OOOE+00 1.500E+03 CS-137 6.630E+03 9.070E+03 0.OOOE+00 3.080E+03 1.020E+03 1.760E+02 0.OOOE+00 5.940E+03 CS-138 8.450E-07 1.670E-06 0.000E+00 1.230E-06 1.210E-07 7.120E-12 0.OOOE+00 8.260E-07 BA-139 1.990E-02 1.420E-05 0.OOOE+00 1.330E-05 8.050E-06 3.530E-02 0.OOOE+00 5.830E-04 BA-140 1.640E+03 2.070E+00 0.OOOE+00 7.020E-01 1.180E+0'0 3.390E+03 0.OOOE+00 1.080E+02 BA-141 5.440E-12 4.120E-15 0.OOOE+00 3.830E-15 2.340E-15 2.570E-21 0.OOOE+00 1.840E-13 BA-142 6.290E-21 6.470E-24 0.OOOE+00 5.460E-24 3.660E-24 8.860E-39 0.OOOE+00 3.960E-22 LA-140 1.690E-01 8.530E-02 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.260E+03 0.OOOE+00 2.250E-02 LA-142 5.720E-05 2.600E-05 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.900E-01 0.OOOE+00 6.480E-06 CE-141 7.710E-01 5.210E-01 0.OOOE+00 2.420E-0 1 0.OOOE+00 1.990E+03 0.OOOE+00 5.910E-02 CE-143 1.070E-01 7.890E+01 0.OOOE+00 3.470E-02*

0.OOOE+00 2.950E+03 0.OOOE+00 8.730E-03 CE-144 4.060E+01 1.700E+01 0.OOOE+00 1.01OE+01 0.OOOE+00 1.370E+04 0.OOOE+00 2.180E+00 PR-143 7.460E-01 2.990E-01 0.OOOE+00 1.730E-01 0.000E+00 3.270E+03 0.OOOE+00 3.700E-02

-PR-144 7.350E-16 3.050E-16 0.OOOE+00 1.720E-16 0.OOOE+00 1.060E-22 0.OOOE+00 3.730E-17 ND-147 5.070E-01 5.860E-01 0.OOOE+00 3.430E-01 0.OOOE+00 2.810E+03 0.OOOE+00 3.510E-02 W-187.

6.050E+00 5.050E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.660E+03 0.OOOE+00 1.770E+00 NP-239 8.550E-02 8.400E-03 0,OO0E+00 2.620E-02 0.060E+00 1.720E+03 0.OOOE+00 4.630E-03 Appendix C Ai Adult Water - Page 3 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX C Ai Adult Dose Factors for use in the Liquid Dose Calculations Agegroup:

ADULT PatlWay:

Fresh Water Fish Sport (FFSP) ni ei/ml Nuclide Bone Liver Thyroid Kidney Lung.,

_Gilli Skin' Total Body H-3 0.OOOE+00 2.260E-01 2.260E-01 2.260E-01 2.260E-01 2.260E-01 0.000E+00 2.260E-01 C-14 3.130E+04 6.260E+03 6.260E+03 6.260E+03 6.260E+03 6.260E+03 0.000E+00 6.260E+03 NA-24 1.350E+02 1.350E+02 1.350E+02 1.350E+02 1.350E+02 1.350E+02 0.000E+00 1.350E+02 P-32 1.320E+06 8.210E+04 0.OOOE+00 0.000E+00 0.000E+00 1.480E+05 0.000E+00 5.100E+04 CR-51 0.OOOE+00 6.000E+00 7.420E-01 2.740E-01 1.650E+00 3.120E+02 0.OOOE+00 1.240E+00 MN-54 0.OOOE+00 4.370E+03 0.OOOE+00 1.300E+03 0.000E+00 1.340E+04 0.OOOE+00 8.330E+02 MN-56 0.OOOE+00 1.730E-01 0.OOOE+00 2.200E-01 0.OOOE+00 5.530E+00 0.000E+00 3.070E-02 FE-55 6.580E+02 4.550E+02 0.OOOE+00 0.000E+00 2.540E+02 2.610E+02 0.OOOE+00 1.060E+02 FE-59 1.020E+03 2.400E+03 0.OOOE+00 0.000E+00 6.720E+02 8.010E+03 O.OOOE+00 9.220E+02 CO-58 0.000E+00 8.830E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.790E+63 0.OOOE+00 1.980E+02 CO-60 0.000E+00 2.560E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.810E+03 0.OOOE+00 5.650E+02 NI-63 3.11OE+04 2.160E+03 0.000E+00 0.OOOE+00 0.OOOE+00 4.500E+02 0.OOOE+00-1.040E+03 NI-65 1.720E-01 2.230E-02 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.660E-01 0.000E+00 1.020E-02 CU-64 0.OOOE+00 2.680E+00 0.000E+00 6.760E+00 0.OOOE+00 2.290E+02 0.OOOE+00 1.260E+00 ZN-65 2.310E+04 7.350E+04 0.000E+00 4.920E+04 0.000E+00 4.630E+04 0.OOOE+00 3.320E+04 ZN-69 7.730E-07 1.480E-06 0.000E+00 9.610E-07 0.OOOE+00 2.220E-07 0.OOOE+00 1.030E-07 BR-83 0.000E+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 5.500E-02 0.000E+00 3.820E-02 BR-84 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 9.850E-18 0.000E+00 1.250E-12 BR-85 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 RB-86 0.OOOE+00 9.730E+04 0.OOOE+00 0.000E+00 0.OOOE+00 1.920E+04 0.000E+00 4.530E+04 RB-88 0.OOOE+00 1.290E-22 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.780E-33 0.000E+00 6.830E-23 RB-89 0.000E+00 1.640E-26 0.OOOE+00 0.000E+00 0.OOOE+00 9.560E-40 0.OOOE+00 1.160E-26 SR-89 2.180E+04 0.000E+00 0.OOOE+00 0.000E+00 0.000E+00 3.500E+03 0.OOOE+00 6.260E+02 SR-90 5.440E+05 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00 1.570E+04 0.000E+00 1.340E+05 SR-91 7.050E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 3.360E+02 0.OOOE+00 2.850E+00 Appendix C Ai Adult Fish - Page 1 of 3 0

0 January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX C A, Adult Dose Factors for use in the Liquid Dose Calculations Agegroup:

ADULT Pathway:.

Fresh Water Fish - Sport (FFSP)

Units:,

mrem/hr /Ci/ml

"_:Nuclide Bone..

.-Liver Thyroid

'jKidney Lung Gilli Skin.

Total Body, SR-92 3.320E-01 0.000E+00 0.000E+00 0.000E+00 0.000E+00 6.570E+00 0.000E+00 1.430E-02 Y-90 4.440E-01 0.000E+00 0.000E+00 0.OOOE+00 0.000E+00 4.710E+03 0.000E+00 1.190E-02 Y-91 8.340E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 4.590E+03 0.000E+00 2.230E-01 Y-91M 1.070E-11 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 3.150E-11 0.000E+00 4.150E-13 Y-92 4.600E-04 0.000E+00 0.000E+00 0.000E+00 0.000E+00 8.060E+00 0.000E+00 1.340E-05 Y-93 3.080E-02 0.OOOE+00 0.000E+00 0.000E+00 0.000E+00 9.770E+02 0.000E+00 8.500E-04 ZR-95 2.380E-01 7.620E-02 0.000E+00 1.200E-01 0.000E+00 2.410E+02 0.000E+00 5.160E-02 ZR-97 4.960E-03 1.000E-03 0.000E+00 1.510E-03 0.000E+00 3.100E+02 0.000E+00 4.570E-04 NB-95 4.380E+02 2.440E+02 0.000E+00 2.410E+02 0.000E+00 1.480E+06 0.000E+00 1.310E+02 MO-99 0.000E+00 8.020E+01 0.000E+00 1.820E+02 0.OOOE+00 1.860E+02 0.OOOE+00 1.530E+01 TC-99M 5.590E-04 1.580E-03 0.OOOE+00 2.400E-02 7.740E-04 9.340E-01 0.OOOE+00 2.010E-02 TC-101 2.610E-33 3.760E-33 0.OOOE+00 6.770E-32 1.920E-33 1.130E-44 0.006E+00 3.690E-32 RU-103 4.350E+00 0.OOOE+00 0.OOOE+00 1.660E+01 0.000E+00 5.080E+02 0.000E+00 1.870E+00 RU-105 8.670E-03 0.OOOE+00 0.000E+00 1.120E-01 0.OOOE+00 5.300E+00 0.OOOE+00 3.420E-03 RU-106 6.570E+01 0.OOOE+00 0.000E+00 1.270E+02 0.000E+00 4.250E+03 0.000E+00 8.320E+00 AG-110M 8.790E-01 8.130E-01 0.000E+00 1.600E+00 0.OOOE+00 3.320E+02 0.000E+00 4.830E-01 TE-125M 2.540E+03 9.190E+02 7.630E+02 1.030E+04 0.000E+00 1.010E+04 0.OOOE+00 3.400E+02 TE-127 1.790E+01 6.440E+00 1.330E+01 7.300E+01 0.000E+00 1.410E+03 0.OOOE+00 3.880E+00 TE-127M 6.440E+03 2.300E+03 1.650E+03 2.620E+04 0.OOOE+00 2.160E+04 0.000E+00 7.850E+02 TE-129 1.630E-05 6.120E-06 1.250E-05 6.850E-05 0.OOOE+00 1.230E-05 0.000E+00 3.970E-06 TE-129M 1.080E+04 4.020E+03 3.710E+03 4.500E+04 0.000E+00 5.430E+04 0.000E+00 1.710E+03 TE-131 8.710E-17 3.640E-17 7.160E-17 3.820E-16 0.000E+00 1.230E-17 0.000E+00 2.750E-17 TE-131M 9.5 10OE+02 4.650E+02 7.370E+02 4.710E+03 0.000E+00 4.620E+04 0.000E+00 3.880E+02 TE-132 1.950E+03 1.260E+03 1.390E+03 1.210E+04 0.000Eý+00 5.960E+04 0.000E+00 1.180E+03

.1-130 7.050E+00 2.080E+01 1.760E+03 3.250E+01 0.000E+00 1.790E+01 0.000E+00 8.210E+00 Appendix C Ai Adult Fish - Page 2 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX C Ai Adult Dose Factors for use in the Liquid Dose Calculations Agegroup:

ADULT Pathway:

Fresh Water Fish - Sport (FFSP) j Units:

mrem/hr / jCi/ml Nuclide

Bone, Liver

,-Thyroid Kidney Lung Gilli I Skin Total-Body, 1-131 1.370E+02 1.960E+02 6.420E+04 3.360E+02 0.OOOE+00 5.170E+01 0.OOOE+00 1.120E+02 1-132 5.270E-03 1.410E-02 4.940E-01 2.250E-02 0.000E+00 2.650E-03 0.OOOE+00 4.940E-03 1-133 2.290E+01 3.990E+01 5.860E+03 6.950E+01 0.000E+00 3.580E+01 0.OOOE+00 1.210E+01 1-134 2.120E-08 5.750E-08 9.960E-07 9.140E-08 0.OOOE+00 5.010E-11 0.OOOE+00 2.060E-08 1-135 1.290E+00 3.370E+00 2.220E+02 5.410E+00 0.OOOE+00 3.810E+00 0.OOOE+00 1.240E+00 CS-134 2.980E+05 7.080E+05 0.OOOE+00 2.290E+05 7.610E+04 1.240E+04 0.OOOE+00-5.790E+05 CS-136 2.960E+04 1.170E+05 0.OOOE+00 6.500E+04 8.900E+03 1.330E+04 0.OOOE+00 8.400E+04 CS-137 3.820E+05 5.220E+05 0.OOOE+00 1.770E+05 5.890E+04 1.010E+04 0.OOOE+00 3.420E+05 CS-138 8.940E-12 1.770E-11 0.OOOE+00 1.300E-11 1.280E-12 7.530E-17 0.OOOE+00 8.750E-12 BA-139 5.650E-06 4.030E-09 0.OOOE+00 3.760E-09 2.280E-09 1.OOOE-05 0.000E+00 1.660E-07 BA-140 1.840E+02 2.310E-01 0.OOOE+00 7.860E-02 1.320E-01 3.790E+02 0.OOOE+00 1.210E+01 BA-141 8.700E-25 6.580E-28 0.OOOE+00 6.120E-28 3.730E-28 4.100E-34 0.OOOE+00 2.940E-26 BA-142 2.570E-42 2.640E-45 0.OOOE+00 2.230E-45 1.490E-45 3.620E-60 0.OOOE+00 1.610E-43 LA-140 9.900E-02 4.990E-02 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.660E+03 0.OOOE+00 1.320E-02 LA-142 2.210E-07 1.0OOE-07 0.OOOE+00 0.OOOE+00 0.OOOE+00 7.330E-04 0.OOOE+00 2.500E-08 CE-141 2.190E-02 1.480E-02 0.OOOE+00 6.890E-03 O.OOOE+00 5.670E+01 0.000E+00 1.680E-03 CE-143 2.380E-03 1.760E+00 0.OOOE+00 7.760E-04 0.OOOE+00 6.590E+01 0.OOOE+00 1.950E-04 CE-144 1.170E+00 4.870E-01 0.OOOE+00 2.890E-01 0.OOOE+00 3.940E+02 0.000E+00 6.260E-02 PR-143 5.230E-0 1 2.100E-01 0.OOOE+00 1.210E-01 0.000E+00 2.290E+03 0.OOOE+00 2.590E-02 PR-144 1.550E-28 6.440E-29 0.OOOE+00 3.630E-29 0.OOOE+00 2.230E-35 0.000E+00 7.880E-30 ND-147 3.530E-01 4.080E-01 0.OOOE+00 2.390E-01 0.OOOE+00 1.960E+03 0.OOOE+00 2.440E-02 W-187 1.470E+02 1.230E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.030E+04 0.OOOE+00 4.300E+01 NP-239 2.120E-02 2.090E-03 0.OOOE+00 6.510E-03 0.OOOE+00 4.280E+02 0.OOOE+00 1.150E-03 Appendix C Ai Adult Fish - Page 3 of 3

0 January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX C Ai Adult Dose Factors for use in the Liquid Dose Calculations Agegr0o u:

ADULT Pathw-ay:

Shoreline Sediment (SHDp)

Units:,-

mrem/hr / gCi/ml Nuclhde Bone Liver Thyroid-

Kidney, Lung'

, *1Gili-7

'Skii<

Total BI dy' H-3 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.O0OE+00 C-14 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 NA-24 6.410E-01 6.410E-01 6.410E-01 6.410E-01 6.410E-01 6.410E-01 7.440E-01 6.410E-01 P-32 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 CR-51 2.500E-01 2.500E-01 2.500E-01 2.500E-01 2.500E-01 2.500E-01 2.960E-01 2.500E-01, MN-54 7.440E+01 7.440E+01 7.440E+01 7.440E+01 7.440E+O1 7.440E+01 8.720E+01 7.440E+01 MN-56 4.840E-02 4.840E-02 4.840E-02 4.840E-02 4.840E-02 4.840E-02 5.720E-02 4.840E-02 FE-55 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 FE-59 1.460E+01 1.460E+01 1.460E+01 1.460E+01 1.460E+01 1.460E+01

.720E+01 1.460E+01 CO-58 2.030E+01 2.030E+01 2.030E+01 2.030E+01 2.030E+01 2.030E+01 2.380E+01 2.030E+01 CO-60 1.150E+03 1.150E+03 1.150E+03 1.150E+03 1.150E+03 1.150E+03 1.360E+03 1.150E+03 NI-63 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 NI-65 1.590E-02 1.590E-02 1.590E-02 1.590E-02 1.590E-02 1.590E-02 1.850E-02 1.590E-02 CU-64 3.260E-02 3.260E-02 3.260E-02 3.260E-02 3.260E-02 3.260E-02 3.690E-02 3.260E-02 ZN-65 4.010E+01 4.010E+01 4.010E+01 4.010E+01 4.010E+01 4.010E+01 4.610E+01 4.010E+01 ZN-69 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 BR-83 2.620E-04 2.620E-04 2.620E-04 2.620E-04 2.620E-04 2.620E-04 3.800E-04 2.620E-04 BR-84 1.090E-02 1.090E-02 1.090E-02 1.090E-02 1.090E-02 1.090E-02 1.270E-02 1.090E-02 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RB-86 4.820E-01 4.820E-01 4.820E-01 4.820E-01 4.820E-01 4.820E-01 5.510E-01 4.820E-01 RB-88 1.780E-03 1.780E-03 1.780E-03 1.780E-03 1.780E-03 1.780E-03 2.030E-03 1.780E-03 RB-89 6.600E-03 6.600E-03 6.600E-03 6.600E-03 6.600E-03 6.600E-03 7.920E-03 6.600E-03 SR-89 1.160E-03 1.160E-03 1.160E-03 1.160E-03 1.160E-03 1.160E-03 1.350E-03 1.160E-03 SR-90 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 SR-91 1.150E-01 1.150E-01 1.150E-01 1.150E-01 1.150E-01 1.150E-01 1.350E-01 1.150E-01 Appendix C Ai Adult Shoreline Sediment - Page 1 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX C Ai Adult Dose Factors for use in the Liquid Dose Calculations Agegroup:

ADULT

-Pathway:

Shoreline Sediment (SHDp)

Uniits:

mrem/hr/ ICi/ml

-Nnclide Bone.

r-i

'Thyroid Kidney Lun Giii sii.

TotalBody SR-92 4.170E-02 4.170E-02 4.170E-02 4.1 70E-02 4..170E-02 4.170E-02 4.630E-02 4.170E-02 Y-90 2.410E-04 2.410E-04 2.410E-04 2.410E-04 2.410E-04 2.410E-04 2.850E-04 2.410E-04 Y-91 5.760E-02 5.760E-02 5.760E-02 5.760E-02 5.760E-02 5.760E-02 6.480E-02 5.760E-02 Y-91M 5.380E-03 5.380E-03 5.380E-03 5.380E-03 5.380E-03 5.380E-03 6.230E-03 5.380E-03 Y-92 9.680E-03 9.680E-03 9.680E-03 9.680E-03 9.680E-03 9.680E-03 1.150E-02 9.680E-03 Y-93 9.840E-03 9.840E-03 9.840E-03 9.840E-03 9.840E-03 9.840E-03 1.350E-02 9.840E-03 ZR-95 1.310E+01 1.310E+01

  • 1.310E+01 1.310E+01 1.310E+01 1.310E+01 1.520E+01 1.310E+01 ZR-97 1.590E-01 1.590E-01 1.590E-01 1.590E-01 1.590E-01 1.590E-01 1.850E-01 1.590E-01 NB-95 7.340E+00 7.340E+00 7.340E+00 7.340E+00 7.340E+00 7.340E+00 8.630E+00 7.340E+00 MO-99 2.140E-01 2.140E-01 2.140E-01 2.140E-01 2.140E-01 2.140E-01 2.480E-01 2.140E-01 TC-99M 9.880E-03 9.880E-03 9.880E-03 9.880E-03 9.880E-03 9.880E-03 1.130E-02 9.880E-03 TC-101 1.090E-03 1.090E-03 1.090E-03 1.090E-03 1.090E-03 1.090E-03 1.210E-03 1.090E-03 RU-103 5.810E+00 5.810E+00 5.810E+00 5.810E+00 5.810E+00 5.810E+00 6.780E+00 5.810E+00 RU-105 3.420E-02 3.420E-02 3.420E-02 3.420E-02 3.420E-02 3.420E-02 3.870E-02 3.420E-02 RU-106 2.270E+01 2.270E+01 2.270E+01 2:270E+01 2.270E+01 2.270E+01 2.720E+01 2.270E+01 AG-110M 1.850E+02 1.850E+02 1.850E+02 1.850E+02 1.850E+02 1.850E+02 2.150E+02 1.850E+02 TE-125M 8.330E-02 8.330E-02 8.330E-02 8.330E-02 8.330E-02 8.330E-02
1. 140E 8.330E-02 TE-127 1.600E-04 1.600E-04 1.600E-04 1.600E-04 1.600E-04 1.600E-04 1.760E-04 1.600E-04 TE-127M 4.920E-03 4.920E-03 4.920E-03 4.920E-03 4.920E-03 4.920E-03 5.810E-03 4.920E-03 TE-129 1.410E-03 1.41 OE-03 1.410E-03 1.410E-03 1.410E-03 1.410E-03 1.670E-03 1.410E-03 TE-129M 1.060E+00 1.060E+00 1.060E+00 1.060E+00 1.060E+00 1.060E+00 1.240E+00 1.060E+00 TE-131 1.570E-03 1.570E-03 1.570E-03 1.570E-03 1.570E-03 1.570E-03 1.850E+00 1.570E-03 TE-131M 4.310E-01 4.310E-01 4.310E-01 4.310E-01 4.310E-01 4.310E-01 5.080E-01 4.310E-01 TE-132 2.270E-0 1 2.270E-0 I 2.270E-01 2.270E-01 2.270E-0 1 2.270E-0 1 2.670E-0 1 2.270E-0 1 11-130 2.960E-01 2.960E-01 2.960E-01 2.960E-01 2.960E-01 2.960E-01 3.590E-01 2.960E-01 Appendix C Ai Adult Shoreline Sediment - Page 2 of 3 0

January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX C Ai Adult Dose Factors for use in the Liouid Dose Calculations Agegroup:

ADULT Pathway:

Shoreline Sediment (SHDp)

Units:

mrem/hr / jtCi/ml

-Nuclide Bone-'--

Liver

.-Thyroid

,Kidney,

-Lung Gilli

<Skiii Total Body 1-131 9.240E-01 9.240E-01 9.240E-01 9.240E-01 9.240E-01 9.240E-01 1.120E+00 9.240E-01 1-132 6.680E-02 6.680E-02 6.680E-02 6.680E-02 6.680E-02 6.680E-02 7.860E-02 6.680E-02 1-133 1.320E-01 1.320E-01 1.320E-01 1.320E-01 1.320E-01 1.320E-01 1.600E-01 1.320E-01 1-134 2.400E-02 2.400E-02 2.400E-02 2.400E-02 2.400E-02 2.400E-02 2.850E-02 2.400E-02 1-135 1.360E-01 1.360E-01 1.360E-01 1.360E-01 1.360E-01 1.360E-01 1.580E-01 1.360E-01 CS-134 3.680E+02 3.680E+02 3.680E+02 3.680E+02 3.680E+02 3.680E+02 4.300E+02 3.680E+02 CS-136 8.100E+00 8.100E+00 8.100E+00 8.100E+00 8.100E+00 8.100E+00 9.180E+00 8.100E+00 CS-137 5.520E+02 5.520E+02 5.520E+02 5.520E+02 5.520E+02 5.520E+02 6.440E+02 5.520E+02 CS-138 1.930E-02 1.930E-02 1.930E-02 1.930E-02 1.930E-02 1.930E-02 2.200E-02 1.930E-02 BA-139 5.680E-03 5.680E-03 5.680E-03 5.680E-03 5.680E-03 5.680E-03 6.390E-03 5.680E-03 BA-140 1.1 OOE+00 1.100E+00 1.100E+00 1.1 OOE+00 1.1 OOE+00 1.1 OOE+00 1.260E+00 1.100E+00 BA-141 2.240E-03 2.240E-03 2.240E-03 2.240E-03 2.240E-03 2.240E-03 2.550E-03 2.240E-03 BA-142 2.410E-03 2.41 OE-03 2.410E-03 2.4 1OE-03 2.410E-03 2.410E-03 2.740E-03 2.410E-ý03 LA-140 1.030E+00 1.030E+00 1.030E+00 1.030E+00 1.030E+00 1.030E+00 1.170E+00 1.030E+00 LA-142 4.080E-02 4.080E-02 4.080E-02 4.080E-02 4.080E-02 4.080E-02 4.890E-02

.4.080E-02 CE-141 7.330E-61 7.330E-01 7.330E-01 7.330E-01 7.330E-01 7.330E-01 8.270E-01 7.330E-01 CE-143 1.240E-01 1.240E-01 1.240E-01 1.240E-01 1.240E-01 1.240E-01

-1.410E-01 1.240E-01 CE-144 3.730E+00 3.730E+00 3.730E+00 3.730E+00 3.730E+00 3.730E+00 4.320E+00 3.730E+00 PR-143 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 PR-144 9.850E-05 9.850E-05 9.850E-05 9.850E-05 9.850E-05 9.850E-05 1.130E-04 9.850E-05 ND-147 4.510E-01 4.510E-01 4.510E-01 4.510E-01 4.510E-01 4.510E-01 5.410E-01 4.510E-0i W-187 1.260E-01 1.260E-01 1.260E-01 1.260E-01 1.260E-01 1.260E-01 1.470E-01 1.260E-01 NP-239 9.180E-02 9.180E-02 9.180E-02 9.180E-02 9.180E-02 9.180E-02 1.060E-01 9.180E-02 Appendix C Ai Adult Shoreline Sediment - Page 3 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX D Ai Teen Factors for use in the Liquid Dose Calculations Agegroup:,'

TEEN Pathway:

Potable Water (PWtr)

Units:

mrem/hr / jtCi/ml Nuclide Bone:--

Liver

'..Thyroid Kidney Lung Gilli Skin Total'Body H-3 0.000E+00 6.160E+00 6.160E+00 6.160E+00 6.160E+00 6.160E+00 0.OOOE+00 6.160E+00 C-14 2.360E+02 4.720E+01 4.720E+0 1 4.720E+01 4.720E+0 1 4.720E+01 0.OOOE+00 4.720E+-01 NA-24 7.690E+01 7.690E+01 7.690E+01 7.690E+01 7.690E+01 7.690E+01 0.000E+00 7.690E+01 P-32 1.570E+04 9.700E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.320E+03 0.OOOE+00 6.070E+02

ýCR-51 0.OOOE+00 0OOOE+00 1.150E-01 4.530E-02 2.950E-01 3.470E+01 0.OOOE+00 2.070E-01 MN-54 0.OOOE+00 3.430E+02 0.OOOE+00 1.020E+02 0.OOOE+00 7.030E+02 0.OOOE+00 6.790E+01 MN-56 0.OOOE+00 3.640E-01 0.OOOE+00 4.610E-01 0.OOOE+00 2.400E+01 0.OOOE+00 6.480E-02 FE-55 2.200E+02 1.560E+02 0.OOOE+00 0.OOOE+00 9.880E+01 6.740E+01 0.OOOE+00 3.630E+01 FE-59 3.390E+02 7.900E+02 0.OOOE+00 0.OOOE+00 2.490E+02 1.870E+03 O.OOOE+00 3.050E+02 CO-58 0.OOOE+00 5.620E+01 0.OOOE+00 0.OOOE+00 0.000E+00 7.750E+02 0.OOOE+00 1.300E+02 CO-60 0.OOOE+00 1.630E+02 0.OOOE+00 0.000E+00 0.OOOE+00 2.130E+03 0.OOOE+00 3.680E+02 NI-63 1.030E+04 7.270E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.160E+02 0.OOOE+00 3.490E+02 NI-65 1.610E+00 2.050E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.11OE+01 0.OOOE+00 9.350E-02 CU-64 0.OOOE+00 3.470E+00

>0.OOOE+00 8.770E+00 0.OOOE+00 2.690E+02 0.OOOE+00 1.630E+00 ZN-65 3.340E+02 1.160E+03 0.OOOE+00 7.430E+02 0.OOOE+00 4.920E+02 0.OOOE+00 5.420E+02 ZN-69 1.070t-04 2.040E-04 0.000E+00 1.330E-04 0.OOOE+00 3.760E-04 0.OOOE+00 1.430E-05 BR-83 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.030E-01 BR-84 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.500E-07 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 4.360E-77 RB-86 0.OOOE+00 1.700E+03 0.OOOE+00 0.OOOE+00 0.000E+00 2.520E+02 0.OOOE+00 7.990E+02 RB-88 0.OOOE+00 3.300E-12 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.830E-19 0.000E+00 1.760E-12 RB-89 0.OOOE+00 2.960E-14 0.OOOE+00 0.000E+00 0.OOOE+00 4.540E-23 0.OOOE+00 2:090E-14 SR-89 2.540E+04 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.030E+03 0.OOOE+00 7.280E+02 SR-90 4.830E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 1.350E+04 0.000E+00 1.190E+05 SR-91 1.950E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 8.850E+02 0.OOOE+00 7.760E+00 Appendix D Ai Teen Water - Page I of 3 0

0 January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX D Ai Teen Factors for use in the Liquid Dose Calculations Agegroup:

TEEN Pathway:

Potable Water (PWtr)

Units:

mrem/hr / jCi/ml Nuclide Bone

  • Liver -

' -Thy-roid,`

Kidney, Lung Gilli Skin'-

Total Body SR-92 8.220E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.090E+02 0.OOOE+00 3.500E-01 Y-90 7.OOOE-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.770E+03 0.OOOE+00 1.880E-02 Y-91 1.160E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.760E+03 0.OOOE+00 3.120E-01 Y-91M 3.330E-07 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 1.570E-05 0.OOOE+00 1.270E-08 Y-92 6.710E-03 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 1.840E+02 0.OOOE+00 1.940E-04 Y-93 9.760E-02 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.980E+03 0.OOOE+00 2.670E-03 ZR-95 2.380E+00 7.520E-01 0.OOOE+00 1.100E+00 0.OOOE+00 1.730E+03 0.OOOE+00 5.170E-01 ZR-97 8.420E-02 1.670E-02 0.000E+00 2.530E-02 0.OOOE+00 4.510E+03 0.OOOE+00 7.670E-03 NB-95 4.730E-01 2.630E-01 0.OOOE+00 2.540E-01 0.OOOE+00 1.120E+03 0.OOOE+00 1.440E-01 MO-99

.0.000E+00 3.090E+02 0.OOOE+00 7.070E+02 0.OOOE+00 5.530E+02 0.OOOE+00 5.890E+01 TC-99M 4.840E-03 1.350E-02 0.OOOE+00 2.010E-01 7.500E-03 8.870E+00 0.OOOE+00 1.750E-01 TC-101 1.120E-17 1.590E-17

/

0.OOOE+00 2.880E-16 9.700E-18 2.720E-24 0.OOOE+00 1.560E-16 RU-103 1.470E+01 0.OOOE+00 0.000E+00 5.180E+01 0.000E+00 1.230E+03 0.OOOE+00 6.280E+00 RU-105 1.940E-01 0.OOOE+00 0.OOOE+00 2.450E+00 0.OOOE+00 1.570E+02 O.OOOE+00 7.540E-02 RU-106 2.280E+02 0.OOOE+00 0.OOOE+00 4.390E+02 0.OOOE+00 1.090E+04 0.OOOE+00 2.870E+01 AG-I IOM 1.190E+01 1.130E+01 0.060E+00 2.150E+01 0.OOOE+00 3.160E+03 0.OOOE+00 6.850E+00 TE-125M 2.210E+02 7.980E+01 6.180E+01 0.OOOE+00 0.OOOE+00 6.530E+02 0.OOOE+00 2.960E+01 TE-127 3.790E+00 1.340E+00 2.610E+00 1.530E+01 0.OOOE+00 2.930E+02 0.000E+00 8.150E-0 1 TE-127M 5.600E+02 1.990E+02 1.330E+02 2.270E+03 0.OOOE+00 1.400E+03 0.OOOE+00 6.660E+01 TE-129 1.920E-03 7.150E-04 1.370E-03 8.040E-03 0.OOOE+00 1.050E-02 0.060E+00 4.660E-04 TE-129M 9.380E+02 3.480E+02 3.030E+02 3.920E+03 0.OOOE+00 3.520E+03 0.OOOE+00 1.480E+02 TE-131 3.490E-09 1.440E-09 2.690E-09 1.520E-08 0.000E+00 2.860E-10 0.OOOE+00 1.090E-09 TE-131M 1.080E+02 5.150E+01 7.750E+01 5.380E+02 0.OOOE+00 4.140E+03 0.OOOE+00 4.300E+01 TE-132 1.820E+02 1.150E+02 1.220E+02 1.11OE+03 0.OOOE+00 3.660E+03 0.000E+00 1.090E+02 1-130 3.050E+01 8.830E+01 7.200E+03 1.360E+02 O.OOOE+00 6.790E+01 0.OOOE+00 3.530E+01 Appendix D Ai Teen Water - Page 2 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual ((6DCM)

January, 2010 Revision 52 APPENDIX D Ai Teen Factors for use in the Liquid Dose Calculations Agegroup:

TEEN Pathway:

Potable Water (PWtr)

Units:

mrem/hr / pCi/ml Niclide Bone Live.-

r

'iThyroid, Kidney "Lung Gilli Skin Total Body 1-131 3.260E+02 4.560E+02 1.330E+05 7.850E+02 0.OOOE+00 9.020E+01 0.OOOE+00 2.450E+02 1-132 4.360E-01 1.140E+00 3.850E+01 1.800E+00 0.OOOE+00 4.970E-01 0.OOOE+00 4.100E-01 1-133 7.830E+01 1.330E+02 1.860E+04 2.330E+02 0.OOOE+00 1.010E+02 0.OOOE+00 4.050E+01 1-134 6.330E-04 1.680E-03 2.800E-02 2.640E-03 0.OOOE+00 2.210E-05 0.OOOE+00 6.020E-04 1-135 1.010E+01 2.600E+01 1.670E+03 4.100E+01 0.OOOE+00 2.880E+01 0.OOOE+00 9.630E+00 CS-134 4.860E+03 1.140E+04 0.OOOE+00 3.640E+03 1.390E+03 1.420E+02 0.OOOE+00 5.310E+03 CS-136 4.860E+02 1.910E+03 0.OOOE+00 1.040E+03 1.640E+02 1.540E+02 0.OOOE+00 1.290E+03 CS-137 6.510E+03 8.660E+03 0.OOOE+00 2.950E+03 1.150E+03 1.230E+02

,, 0.OOOE+00 3.020E+03 CS-138 8.300E-07 1.590E-06 0.000E+00 1.180E-06 1.370E-07 7.230E-10 0.OOOE+00 7.970E-07 BA-139 1.990E-02 1.400E-05 0.000E+00 1.320E-05 9.670E-06 1.780E-01 0.OOOE+00 5.810E-04 BA-140 1.610E+03 1.970E+00 0.OOOE+00 6.680E-01 1.320E+00 2.480E+03 0.OOOE+00 1.040E+02 BA-141 5.420E-12 4.050E-15 0.OOOE+00 3.760E-15 2.770E-15 1.150E-17 0.OOOE+00 I.810E-13 BA-142 6.170E-21 6.170E-24 0.OOOE+00 5.220E-24 4.100E-24 1.890E-32 0.OOOE+00 3.800E-22 LA-140 1.650E-01 8.090E-02 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.640E+03 0.OOOE+00 2.150E-02 LA-142 5.590E-05 2.480E-05 0.000E+QQ 0:000E+00 0.OOOE+00 7.550E-01 0.OOOE+00 6.180E-06 CE-141 7.650E-01 5.11OE-01 0.OOOE+00 2.400E-01 0.OOOE+00 1.460E+03 0.OOOE+00 5.870E-02 CE-143 1.060E-01 7.730E+01 0.OOOE+00 3.460E-02 0.OOOE+00 2.320E+03 0.OOOE+00 8.630E-03 CE-144 4.040E+01 1.670E+01 0.OOOE+00 9.990E+00 0.OOOE+00 1.020E+04 0.000E+00 2.170E+00 PR-143 7.420E-01 2.960E-01 0.OOOE+00 1.720E-01 0.OOOE+00 2.440E+03 0.OOOE+00 3.700E-02 PR-144 7.330E-16 3.OOOE-16 0.OOOE+00 1.720E-16 0.OOOE+00 8.080E-19 0.OOOE+00 3.720E-17 ND-147 5.280E-01 5.750E-01 0.OOOE+00 3.370E-01 0.OOOE+00 2.070E+03 0.OOOE+00 3.440E-02 W-187 5.990E+00 4.880E+00 0.000E+00 0.OOOE+00 0.OOOE+00 1.320E+03 0.OOOE+00 1.710E+00 NP-239 8.830E-02 8.330E-03 0.OOOE+00 2.61 QE-02 0.OOOE+00 1.340E+03 0.000E+00 4.630E-03 Appendix D Ai Teen Water - Page 3 of 3

0 January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX D Ai Teen Dose Factors for use in the Liquid Dose Calculations

, Agegroup:

TEEN Pathway:

Fresh Water Fish - Sport (FFSP) iUnits!5- ":

mrem/hr / ptCi/ml Nuncide Bone

-. Liv'er.

Thyroid :

Kidne

- Lung *Gi Ski' Total Body H;-3 0.OOOE+00 1.740E-01 1.740E-01 1.740E-01 1.740E-01 1.740E-01

  • 0.000E+00 1.740E-01 C-14 3.410Et04 6.810E+03 6.810E+03 6.810E+03 6.810E+03 6.810E+03 0.OOOE+00 6.810E+03 NA-24 1.390E+02 1.390E+02 1.390E+02 1.390E+02 1.390E+02 1.390E+02 0.OOOE+00 1.390E+02 P-32 1.440E+06 8.91 OE+04 0.OOOE+00 0.OOOE+00 0.000E+00 1.210E+05 0.OOOE+00 5.580E+04 CR-51 0.OOOE+00 0.OOOE+00 7.120E-01 2.810E-01 1.830E+00 2.150E+02 0.OOOE+00 1.280E+00 MN-54 0.OOOE+00 4.300E+03 0.OOOE+00 1.280E+03 0.OOOE+00 8.810E+03 0.OOOE+00 8.520E+02 MN-56 0.OOOE+00 1.810E-01 0.OOOE+00 2.300E-,01 0.OOOE+00 1.190E+01 0.OOOE+00 3.230E-02 FE-55 6.890E+02 4.880E+02 0.OOOE+00 0.OOOE+00 3.100E+02 2.11OE+02 0.OOOE+00 1.140E+02 FE-59 1.050E+03 2.460E+03 0.OOOE+00 0.OOOE+00 7.760E+02 5.820E+03 0.OOOE+00 9.500E+02 CO-58 0.OOOE+00 8.780E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.210E+03 0.OOOE+00 2.020E+02 CO-60 0.OOOE+00 2.560E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.340E+03 0.OOOE+00 5.770E+02 NI-63 3.230E+04 2.280E+03 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.630E+02 0.OOOE+00 1.090E+03 NI-65 1.860E-01 2.370E-02 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.290E+00 0.OOOE+00 1.080E-02 CU-64 0.OOOE+00 2.820E+00 0.OOOE+00 7.140E+00 0.OOOE+00 2.190E+02 0.OOOE+00 1.330E+00 ZN-65 2.100E+04 7.280E+04 0.OOOE+00 4.660E+04 0.OOOE+00 3.080E+04 0.OOOE+00 3.390E+04 ZN-69 8.410E-07 1.600E-06 0.OOOE+00 1.050E-06 0.OOOE+00 2.950E-06 0.000E+00 1.120E-07 BR-83 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.160E-02 BR-84 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.320E-12 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 RB-86 0.OOOE+00 1.050E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.550E+04 0.OOOE+00 4.920E+04 RB-88 0.OOOE+00 1.380E-22 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.180E-29 0.OOOE+00 7.360E-23 RB-89 0.OOOE+00 1.720E-26 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.630E-35 0.OOOE+00 1.220E-26 SR-89 2.370E+04 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.830E+03 0.OOOE+00 6.800E+02 SR-90 4.540E+05 0.OOOE+00 0.OOE+00 0.OOOE+00 0.OOOE+00 1.270E+04 0.OOOE+00 1.120E+05 SR-91 7.640E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.470E+02 0.OOOE+00 3.040E+00 Appendix D Ai Teen Fish - Page 1 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX D A: Teen Dose Factors for use in the inuid Dose Calculations A. Teen Dose Factors for use in the Linuid DoseCalculations SAgegroup:

TEEN Pathway:

Fresh Water Fish - Sport (FFSP) tiUnits:,

mrem/hr / xCi/ml

.Nuclide Bone Liver Thyroid -

Kidney Lung Gilli Skin "

Ttal Body SR-92 3.590E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 9.130E+00 0.OOOE+00 1.530E-02 Y-90 4.820E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.980E+03 0.OOOE+00 1.300E-02 Y-91 9.060E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.710E+03 0.OOOE+00 2.430E-01 Y-91M 1.160E-11 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.470E-10 0.OOOE+00 4.430E-13 Y-92 5.020E-04 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.380E+01 0.OOOE+00 1.450E-05 Y-93 3.350E-02 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.020E+03 0.OOOE+00 9.190E-04 ZR-95 2.450E-01 7.740E-02 0.OOOE+00 1.140E-01 0.OOOE+00 1.790E+02 0.OOOE+00 5.320E-02 ZR-97 5.330E-03 1.050E-03 0.OOOE+00 1.600E-03 0.OOOE+00 2.850E+02 0.OOOE+00 4.860E-04 NB-95 4.410E+02 2.450E+02 0.OOOE+00 2.370E+02 0.OOOE+00 1.050E+06 0.OOOE+00 1.350E+02 MO-99 0.000E+00 8.550E+01 0.OOOE+00 1.960E+02 0.OOOE+00 1.530E+02 0.OOOE+00 1.630E+01 TC-99M 5.720E-04 1.600E-03 0.OOOE+00 2.380E-02 8.860E-04 1.050E+00 0.OOOE+00 2.070E-02 TC-101 2.820E-33 4.010E-33 0.OOOE+00 7.240E-32 2.440E-33 6.840E-40 0.OOOE+00 3.930E-32 RU-103 4.570E+00 0.OOOE+00 0.OOOE+00 1.610E+01 0.OOOE+00 3.820E+02 0.OOOE+00 1.950E+00 RU-105 9.350E-03 0.OOOE+00 0.OOOE+00 1.180E-01 0.OOOE+00 7.550E+00 0.OOOE+00 3.630E-03 RU-106 7.140E+01 0.OOOE+00 0.OOOE+00 1.380E+02 0.OOOE+00 3.420E+03 0.000E+00 8.990E+00 AG-110M 8.580E-01 8.120E-01 0.OOOE+00 1.550E+00 0.0003E+00 2.280E+02 0.OOOE+00 4.940E-01 TE-125M 2.760E+03 9.950E+02 7.710E+02 0.OOOE+00 0.OOOE+00 8.150E+03 0.OOOE+00 3.690E+02 TE-127 1.960E+01 6.950E+00 1.350E+01 7.940E+01 0.000E+00 1.510E+03 0.OOOE+00 4.220E+00 TE-127M 7.010E+03 2.490E+03 1.670E+03 2.840E+04 0.OOOE+00 1.750E+04 0.OOOE+00 8.340E+02 TE-129 1.770E-05 6.600E-06 1.260E-05 7.430E-05 0.OOOE+00 9.680E-05 0.OOOE+00 4.310E-06 TE-129M 1.160E+04 4.320E+03 3.760E+03 4.870E+04 0.OOOE+00 4.370E+04 0.OOOE+00 1.840E+03 TE-131 9.400E-17 3.870E-17 7.240E-17 4.11 E-16 0.OOOE+00 7.710E-18 0.OOOE+00 2.940E-17 TE-131M 1.020E+03 4.900E+02 7.370E+02 5.11OE+03 0.OOOE+00 3.930E+04 0.OOOE+00 4.090E+02 TE-132 2.060E+03 1.300E+03 1.370E+03 1.250E+04 0.OOOE+00 4.130E+04 0.OOOE+00 1.230E+03 1-130 7.320E+00 2.120E+01 1.730E+03 3,260E+01 0.OOOE+00 1.630E+01 0.OOOE+00 8.460E+00 Appendix D Ai Teen Fish - Page 2 of 3

January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX D A_ Teen Dose Factors for use in the Liquid Dose Calculations Agegroup:

TEEN P~athway:

Fresh Water Fish - Sport (FFSP)

Units.:

mrem/hr / J4Ci/ml Nuclide Boneg Liver Thyroid' pKidney LUng

' Gilir.fSk'i Total Body, 1-131 1.470E+02 2.060E+02 6.OOOE+04 3.540E+02 0.OOOE+00 4.070E+01 0.OOOE+00 1.100E+02 1-132 5.520E-03 1.440E-02 4.870E-01 2.280E-02 0.OOOE+00 6.290E-03 0.000E+00 5.180E-03 1-133 2.470E+01 4.190E+01 5.850E+03 7.350E+01 0.OOOE+00 3.170E+01 0.OOOE+00 1.280E+01 1-134 2.220E-08 5.890E-08 9.810E-07 9.280E-08 0.000E+00 7.760E-10 0.OOOE+00 2.11OE-08 1-135 1.350E+00 3.480E+00 2.240E+02 5.490E+00 0.OOOE+00 3.850E+00 0.OOOE+00 1.290E+00 CS-134 3.050E+05 7.180E+05 0.000E+00 2.280E+05 8.710E+04 8.930E+03 0.OOOE+00 3.330E+05 CS-136 2.970E+04 1.170E+05 0.OOOE+00 6.370E+04 1.000E+04 9.410E+03 0.OOOE+00 7.860E+04 CS-137 4.090E+05 5.440E+05 0.OOOE+00 1.850E+05 7.190E+04 7.730E+03 0.OOOE+00 1.890E+05 CS-138 9.580E-12 1.840E-11 0.OOOE+00 1.360E-11 1.580E-12 8.340E-15 0.000E+00 9.190E-12 BA-139 6.170E-06 4.340E-09 0.000E+00 4.090E-09 2.990E-09 5.510E-05 0.000E+00 1.800E-07 BA-140 1.960E+02 2.410E-01 0.OOOE+00 8.160E-02 1.620E-01 3.030E+02 0.000E+00 1.260E+O1 BA-141 9.450E-25 7.050E-28 0.000E+00 6.550E-28 4.830E-28 2.010E-30 0.000E+00 3.150E-26 BA-142 2.750E-42 2.750E-45 0.000E+00 2.320E-45 1.830E-45 8.430E-54 0.OOOE+00 1.690E-43' LA-140 1.050E-01 5.160E-02 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.960E+03 0.000E+00 1.370E-02 LA-142 2.350E-07 1.040E-07 0.000E+00 0.OOOE+00 0.000E+00 3.180E-03 0.000E+00 2.600E-08 CE-141 2.370E-02 1.590E-02 0.000E+00 7.460E-03 0.OOOE+00 4.540E+01 0.000E+00 1.820E-03 CE-143 2.590E-03 1.880E+00 0.OOOE+00 8.450E-04 0.OOOE+00 5.660E+01 0.OOOE+00 2.100E-04 CE-144 1.270E+00 5.240E-01 0.OOOE+00 3.130E-01 0.OOOE+00 3.180E+02 0.OOOE+00 6.810E-02 PR-143 5.680E-01 2.270E-01 0.OOOE+00 1.320E-01 0.OOOE+00 1.870E+03 0.OOOE+00 2.830E-02 PR-144 1.690E-28 6.900E-29 0.OOOE+00 3.960E-29 0.OOOE+00 1.860E-31 0.000E+00 8.550E-30 ND-147 4.020E-01 4.370E-01 0.OOOE+00 2.560E-01 0.OOOE+00 1.580E+03 0.OOOE+00 2.620E-02 W-187 1.590E+02 1.300E+02 0.OOOE+00 0.000E+00 0.OOOE+00 3.510E+04 0.OOOE+00 4.540E+01 NP-239 2.390E-02 2.260E-03 0.OOOE+00 7.080E-03 0.OOOE+00 3.630E+02 0.000E+00 1.250E-03 Appendix D Ai Teen Fish - Page 3 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX D A, Teen Dose Factors for use in the Liquid Dose Calculations Agegroup-TEEN Pathway:

Shoreline Sediment (SHDp)

-Units:-

mrem/hr / jtCi/ml Nuclide

'Bone,,--' -

Liver Thyroid Kidney.

Lun illi Skin Total Body, H-3 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 C-14 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 NA-24 3.580E+00 3.580E+00 3.580E+00 3.580E+00 3.580E+00 3.580E+00 4.150E+00 3.580E+00 P-32 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 CR-51 1.400E+00 1.400E+00 1.400E+00 1.400E+00 1.400E+00 1.400E+00 1.650E+00 1.400E+00 MN-54 4.150E+02 4.150E+02 4.150E+02 4.150E4-02 4.150E+02 4.150E+02 4.870E+02 4.150E+02 MIN-56 2.700E-01 2.700E-01 2.700E-01 2.700E-01 2.700E-01 2.700E-01 3.200E-01 2.700E-01 FE-55 0.OOOE+00 0.OOOE+00 0.000E+00 0000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 FE-59 8.180E+01 8.180E+01 8.180E+01 8.180E+01 8.180E+01 8.180E+01 9.610E+01 8.180E+01 CO-58

1. 140E+02
1. 140E+02
1. 140E+02
1. 140E+02 1.140E+02
1. 140E+02 1.330E+02
1. 140E+02 CO-60 6.440E+03 6.440E+03 6.440E+03 6.440E+03 6.440E+03 6.440E+03 7.580E+03 6.440E+03 NI-63 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 NI-65 8.900E-02 8.900E-02 8.900E-02 8.900E-02 8.900E-02 8.900E-02 1.030E-01 8.900E-02 CU-64 1.820E-01 1.820E-01 1.820E-01 1.820E-01 1.820E-01 1.820E-01 2.060E-01 1.820E-01 ZN-65 2.240E+02 2.240E+02 2.240E+02 2.240E+02 2.240E+02 2.240E+02 2.580E+02 2.240E+02 ZN-69 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0'OOOE+00 0.000E+00 BR-83 1.460E-03 1.460E-03 1.460E-03 1.460E-03 1.460E-03 1.460E-03 2.120E-03 1.460E-03 BR-84 6.070E-02 6.070E-02 6.070E-02 6.070E-02 6.070E-02 6.070E-02 7.080E-02 6.070E-02 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 "0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RB-86 2.690E+00 2.690E+00 2.690E+00 2.690E+00 2.690E+00 2.690E+00 3.080E+00 2.690E+00 RB-88 9.910E-03 9.910E-03 9.910E-03 9.910E-03 9.910E-03 9.910E-03 1.130E-02 9.910E-03 RB-89 3.680E-02 3.680E-02 3.680E-02 3.680E-02 3.680E-02 3.680E-02 4.420E-02 3.680E-02 SR-89 6.490E-03 6.490E-03 6.490E-03 6.490E-03 6.490E-03 6.490E-03 7.530E-03 6.490E-03 SR-90 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 SR-91 6.440E-01 6.440E-01 6.440E-01 6.440E-01 6.440E-01 6.440E-01 7.530E-01 6.440E-01 Appendix D Ai Teen Shoreline Sediment - Page 1 of 3 0
0 January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

Ai Teen Dose APPENDIX D Factors for use in the Liquid Dose Calculations m

Agegroup:

TEEN Pathway:

Shoreline Sediment (SHDp)

Units:

mrem/hr / jt&i/ml Nuclide' B6ne.`-ý"

Liver Thyroid Kidney Lng Gili.

Slinr Total Bodyt SR-92 2.330E-01 2.330E-01 2.330E-01 2.330E-01 2.330E-01 2.330E-01 2.590E-01 2.330E-01 Y-90 1.350E-03 1.350E-03 1.350E-03 1.350E-03 1.350E-03 1.350E-03 1.590E-03 1.350E-03 Y-91 3.220E-01 3.220E-01 3.220E-01 3.220E-01 3.220E-01 3.220E-01 3.620E-01 3.220E-01 Y-91M 3.010E-02 3.010E-02 3:010E-02 3.010E-02 3.010E-02 3.010E-02 3.480E-02

  • 3.010E-02 Y-92 5.41 OE-02 5.41 OE-02 5.41 OE-02 5.410E-02 5.410E-02 5.410E-02 6.420E-02 5.410E-02 Y-93.

5.500E-02 5.500E-02 5.500E-02 5.500E-02 5.500E-02 5.500E-02 7.520E-02 5.500E-02 ZR-95 7.330E+01 7.330E+01 7.330E+01 7.330E+01 7.330E+01 7.330E+01 8.510E+01 7.330E+01 ZR-97 8.870E-01 8.870E-01 8.870E-01 8.870E-01 8.870E-01 8.870E-01 1.030E+00 8.870E-01 NB-95 4.100E+01 4.100E+01 4.100E+01 4.100E+01 4.100E+01 4.100E+01 4.820E+01 4.100E+01 MO-99 1.200E+00 1.200E+00 1.200E+00 1.200E+00 1.200E+00 1.200E+00 1.390E+00 1.200E+00 TC-99M 5.520E-02 5.520E-02 5.520E-02 5.5.520E-0 2.520E-02 5.520E-02 6.320E-02 5.520E-02 TC-101 6.100E-03 6.100E-03 6.100E-03 6.100E-03 6.100E-03 6.100E-03 6.780E-03 6.100E-03 RU-103 3.250E+01 3.250E+01 3.250E+01 3.250E+01 3.250E+01 3.250E+01 3.790E+01 3.250E+01 RU-105 1.910E-01 1.910E-01 1.910E-01 1.910E-01 1.910E-01 1.910E-01 2.160E-01 1.910E-01 RU-106 1.270E+02 1.270E+02 1.270E+02 1.270E+02 1.270E+02 1.270E+02 1.520E+02 1.270E+02 AG-i 10M 1.030E+03 1.030E+03 1.030E+03 1.030E+03 1.030E+03 1.030E+03 1.200E+03 1.030E+03 TE-125M 4.650E-01 4.650E-01 4.650E-01 4.650E-01 4.650E-01 4.650E-01 6.380E-01 4.650E-01 TE-127 8.920E-04 8.920E-04 8.920E-04 8.920E-04 8.920E-04 8.920E-04 9.820E-04 8.920E-04 TE-127M 2.750E-02 2.750E-02 2.750E-02 2.750E-02 2.750E-02 2.750E-02 3.250E-02 2.750E-02 TE-129 7.860E-03 7.860E-03 7.860E-03 7.860E-03 7.860E-03 7.860E-03 9.300E-03 7.860E-03 TE-129M 5.930E+00 5.930E+00 5.930E+00 5.930E+00 5.930E+00 5.930E+00 6.930E+00 5.930E+00 TE-131 8.750E-03 8.750E-03 8.750E-03 8.750E-03 8.750E-03 8.750E-03 1.030E+01 8.750E-03 TE-131M 2.410E+00 2.410E+00 2.410E+00 2.410E+00 2.410E+00 2.410E+00 2.840E+00 2.410E+00 TE-132 1.270E+00 1.270E+00 1.270E+00 1.270E+00 1.270E+00 1.270E+00 1.490E+00 L270E+00 1-130 1.650E+00 1.650E+00 1.650E+00 1.650E+00 1.650E+00 1.650E+00 2.010E+00 1.650E+00 Appendix D Ai Teen Shoreline Sediment - Page 2 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX D A_ Teen Dose Factors for use in the Liquid Dose Calculations

  • Agegroup:

TEEN Pathway:

Shoreline Sediment (SHDp)

L Units:

  • mrem/hr / pCi/ml

'Nuclide"'-

Bone-".'

"',Liver Thyroid

'-:kidney Lung Giili Skinii. "7* ',otal Body 1-131 5.160E+00 5.160E+00 5.160E+00 5.160E+00 5.160E+00 5.160E+00 6.260E+00 5.160E+00 1-132 3.730E-01 3.730E-01 3.730E-01 3.730E-01 3.730E-01 3.730E-01 4.390E-01 3.730E-01 1-133 7.350E-01 7.350E-01 7.350E-01 7.350E-01 7.350E-01 7.350E-01 8.930E-01 7.350E-01 1-134 1.340E-01 1.340E-01 1.340E-01 1.340E-01 1.340E-01 1.340E-01 1.590E-01 1.340E-01 1-135 7.570E-01 7.570E-01 7.570E-01 7.570E-01 7.570E-01 7.570E-01 8.830E-01 7.570E-01 CS-134 2.060E+03 2.060E+03 2.060E+03 2.060E+03 2.060E+03 2.060E+03 2.400E+03 2.060E+03 CS-136 4.520E+01 4.520E+01 4.520E+01 4.520E+01 4.520E+O1 4.520E+01 5.130E+01 4.520E+01 CS-137 3.080E+03 3.080E+03 3.080E+03 3.080E+03 3.080E+03 3.080E+03 3.590E+03 3.080E+03 CS-138 1.080E-01 1.080E&01 1.080E-01 1.080E-01 1.080E-01 1.080E-01 1.230E-01 1.080E-01 BA-139 3.170E-02 3.170E-02 3.170E-02 3.170E-02 3.170E-02 3.170E-02 3.570E-02 3.170E-02 BA-140 6.150E+00 6.150E+00 6.150E+00 6.150E+00 6.150E+00 6.150E+00 7.030E+00 6.150E+00 BA-141 1.250E-02 1.250E-02 1.250E-02 1.250E-02 1.250E-02 1.250E-02 1.420E-02 1.250E-02 BA-142 1.340E-02 1.340E-02 1.340E-02 1.340E-02 1.340E-02 1.340E-02 1.530E-02 1.340E-02 LA-140 5.760E+00 5.760E+00 5.760E+00 5.760E+00 5.760E+00 5.760E+00

-6.530E+00 5.760E+00 LA-142 2.280E-01 2.280E-01 2.280E-01 2.280E-01 2.280E-01 2.280E-01 2.730E-01 2.280E-01 CE-141 4.090E+00 4.090E+00 4.090E+00 4.090E+00 4.090E+00 4.090E+00 4.620E+00 4.090E+00 CE-1.43 6.930E-01 6.930E-01 6.930E-01 6.930E-01 6.930E-01 6.930E-01 7.870E-01 6.930E-01 CE-144 2.080E+01 2.080E+01 2.080E+01 2.080E+01 2.080E+01 2.080E+01 2.410E+01 2.080E+01 PR-143 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 PR-144 5.500E-04 5.500E-04 5.500E-04 5.500E-04 5.500E-04 5.500E-04 6.320E-04 5.500E-04 ND-147 2.520E+00 2.520E+00 2.520E+00 2.520E+00 2.520E+00 2.520E+00 3.020E+00 2.520E+00 W-187 7.050E-01 7.050E-01 7.050E-01 7.050E-01 7.050E-01 7.050E-01 8.190E-01 7.050E-01 NP-239 5.130E-01 5.130E-01 5.130E-01 5.130E-01 5.130E-01 5.130E-01 5.930E-01 5.130E-01 Appendix D Ai Teen Shoreline Sediment - Page 3 of 3 0'

January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX E Ai Child Dose Factors for use in the Liouid Dose Calculations Agegroup:

CHILD "Pathway:

Potable Water (PWtr)

Units:.,

mrem/hr / pCi/ml Nuclide Bon-'

Liver,:','

Thyroid';

K'dney Lung.

Gilli iSkii Total BodT H-3 0.OOOE+00 1.180E+01 1.180E+01 1.180E+01 1.180E+01 1.180E+01 0.000E+00 1.180E+01 C-14 7.030E+02 1.41 OE+02 1.41 OE+02 1.410E+02 1.410E+02 1.410E+02 0.OOOE+00 1.410E+02 NA-24 1.940E+02 1.940E+02 1.940E+02 1.940E+02 1.940E+02 1.940E+02 0.OOOE+00 1.940E+02 P-32 4.680E+04 2.190E+03 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.290E+03 0.000E+00 1.800E+03 CR-51 0.OOOE+00 0.OOOE+00 2.840E-01 7.750E-02 5.180E-01 2.710E+01 0.OOOE+00 5.11OE-01 MN-54 0.OOOE+00 6.210E+02 0.OOOE+00 1.740E+02 0.OOOE+00 5.220E+02 0.OOOE+00 1.660E+02 MN-56 0.OOOE+00 7.700E-01 0.OOOE+00 9.320E-01 0.OOOE+00 1.120E+02 0.OOOE+00 1.740E-01 FE-55 6.680E+02 3.550E+02 0.OOOE+00 0.000E+00 2.010E+02 6.570E+01 0.000E+00 1.100E+02 FE-59 9.520E+02 1.540E+03 0.OOOE+00 0.OOOE+00 4.470E+02 1.600E+03 0.OOOE+00 7.670E+02 CO-58 0.OOOE+00 1.040E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.070E+02 0.OOOE+00 3.190E+02 CO-60 0.OOOE+00 3.080E+02 0.000E+00 0.OOOE+00 0.OOOE+00 1.700E+03 0.OOOE+00 9.070E+02 NI-63 3.130E+04 1.670E+03 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.130E+02 0.000E+00 1.060E+03 NI-65

.4.760E+00 4.480E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.490E+01 0.OOOE+00 2.610E-01 CU-64 0.OOOE+00 7.390E+00 0.OOOE+00 1.780E+01 0.OOOE+00 3.470E+02 0.OOOE+00 4.460E+00 ZN-65 7.950E+02 2.120E+03 0.OOOE+00 1'.340E+03 0.OOOE+00 3.720E+02 0.OOOE+00 1.320E+03 ZN-69 3.190E-04 4.610E-04 0.OOOE+00 2.800E-04 0.OOOE+00 2.900E-02 0.OOOE+00 4.260E-05 BR-83 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.060E-01 BR-84 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.O00E+00 1.780E-06 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.300E-76 RB-86 0.OOOE+00 3.820E+03 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.460E+02 0.OOOE+00 2.350E+03 RB-88 0.OOOE+00 7.360E-12 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.610E-13 0.000E+00 5.11OE-12 RB-89 0.OOOE+00 6.300E-14 0.OOOE+00 0.OOOE+00 0.000E+00 5.490E-16 0.OOOE+00 5.600E-14 SR-89 7.620E+04 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.950E+03 0.OOOE+00 2.180E+03 SR-90 9.880E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.330E+04 0.OOOE+00 2.5 1OE+05 SR-91 5.810E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.280E+03 0.OOOE+00 2.190E+01 Appendix E Ai Child Water - Page I of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX E A_ Child Dose Factors for use in the Liquid Dose Calculations Agegroup:

CHILD

--Pathway:

Potable Water (PWtr)

Units:-,

mrem/hr / gCi/ml Nuclide B6neý,

Liver Thyroid.

Kdneys

Lung, Gilli SkiSn TotalBody SR-92 2.430E+01 O.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 4.610E+02 0.000E+00 9.760E-01 Y-90 2.100E+00 0.OOOE+00 0.000E+00 0.000E+00 0.OOOE+00 5.980E+03 0.000E+00 5.620E-02 Y-91 3.480E+01 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00 4.640E+03 0.000E+00 9.310E-01 Y-91M 9.860E-07 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.930E-03 0.OOOE+00 3.590E-08 Y-92 2.000E-02 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 5.770E+02 0.000E+00 5.710E-04 Y-93 2.900E-01 0.000E+00 0.OOOE+00 0.000E+00 0.OOOE+00 4.330E+03 0.000E+00.

7.970E-03 ZR-95 6.710E+00 1.470E+00 0.OOOE+00 2.1 10E+00 0.OOOE+00 1.540E+03 0.000E+00 1.310E+00 ZR-97 2.480E-01 3.590E-02 0.000E+00 5.150E-02 0.OOOE+00 5.440E+03 0.OOOE+00 2.120E-02 NB-95 1.300E+00 5.040E-01 0.OOOE+00 4.740E-01 0.000E+00 9.330E+02 0.000E+00 3.600E-01 MO-99 O.OOOE+00 6.820E+02.

0.OOOE+00 1.460E+03 0.OOOE+00 5.640E+02 0.OOOE+00 1.690E+02 TC-99M 1.350E-02 2.640E-02 0.OOOE+00 3.840E-01 1.340E-02 1.500E+01 0.060E+00 4.380E-01 TC-101 3.330E-17 3.480E-17 0.OOOE+00 5.940E-16 1.840E-17 1.11OE-16 0.OOOE+00 4.410E-16 RU-103 4.210E+01 0.OOOE+00 0.OOOE+00 1.060E+02 0.OOOE+00 1.090E+03 0.OOOE+00 1.620E+01 RU-105 5.750E-01 0.OOOE+00 0.OOOE+00 5.060E+00 0.OOOE+00 3.750E+02 0.OOOE+00 2.090E-01 RU-106 6.800E+02 0.OOOE+00 0.OOOE+00 9.180E+02 0.OOOE+00 1.060E+04 0.OOOE+00 8.480E+01 AG-110M 3.130E+01 2.11OE+01 0.OOOE+00 3.940E+01 0.OOOE+00 2.510E+03 0.OOOE+00 1.690E+01 TE-125M 6.590E+02 1.790E+02 1.850E+02 0.OOOE+00 0.OOOE+00 6.360E+02 0.OOOE+00 8.780E+01 TE-127 1.130E+01 3.050E+00 7.820E+00 3.210E+01 0.OOOE+00 4.410E+02 0.OOOE+00 2.420E+00 TE-127M 1.670E+03 4.510E+02 4.OOOE+02 4.780E+03 0.OOOE+00 1.360E+03 0.OOOE+00 1.990E+02 TE-129 5.730E-03 1.600E-03 4.090E-03 1.680E-02 0.OOOE+00 3.570E-01 0.OOOEt00 1.360E-03 TE-129M 2.800E+03 7.830E+02 9.030E+02 8.230E+03 0.OOOE+00 3.420E+03 0.OOOE+00 4.350E+02 TE-131 1.040E-08 3.160E-09 7.930E-09 3.140E-08 0.000E+00 5.450E-08 0.OOOE+00 3.090E-09 TE-131 M 3.170E+02 1.100E+02 2.260E+02 1.060E+03 0.OOOE+00 4.450E+03 0.OOOE+00

1. 1 70E+02 TE-132 5.280E+02 2.340E+02 3.400E+02 2.170E+03 0.000E+00 2.350E+03 0.OOOE+00 2.820E+02 1-130 8.650E+01 1.750E+02 1.930E+04 2.610E+02 0.OOOE+00 8.180E+01 0.OOOE+00 9.010E+01 Appendix E Ai Child Water - Page 2 of 3

0 January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX E Ai Child Dose Factors for use in the Liouid Dose Calculations Agegroup:-

CHILD Pathway:,-

Potable Water (PWtr) tUinits:.-

mrem/hr / jtCi/ml Nuclide Bone Liver j

Thyroid Kidney.-.

.Lung Gillii Skin Total Body 1-131 9.580E+02 9.630E+02 3.190E+05 1.580E+03 -

0.OOOE+00 8.580E+01 0.OOOE+00 5.470E+02 1-132 1.250E+00 2.300E+00 1.070E+02 3.520E+00 0.000E+00 2.710E+00 0.OOOE+00 1.060E+00 1-133 2.310E+02 2.850E+02 5.300E+04 4.750E+02 0.OOOE+00 1.150E+02 0.OOOE+00 1.080E+02 1-134 1.820E-03 3.370E-03 7.760E-02 5.160E-03 0.000E+00 2.240E-03 0.000E+00 1.550E-03 1-135 2.890E+01 5.21 OE+0 1 4.61 OE+03 7.990E+01 O.OOOE+00 3.970E+01 0.000E+00 2.460E+01 CS-134 1.360E+04 2.230E+04 0.OOOE+00 6.920E+03 2.480E+03 1.200E+02 0.000E+00 4.710E+03 CS-136 1.330E+03 3.660E+03 0.OOOE+00 1.950E+03 2.910E+02 1.290E+02 0.OOOE+00 2.370E+03 CS-137 1.900E+04 1.820E+04 0.OOOE+00 5.930E+03 2.130E+03 1.140E+02 0.OOOE+00 2.690E+03 CS-138 2.440E-06 3.390E-06 0.OOOE+00 2.380E-06 2.570E-07 1.560E-06 O.OOOE+00 2.150E-06 BA-139 5.940E-02 3.170E-05 0.OOOE+00 2.770E-05 1.860E-05 3.430E+00 0.OOOE+00 1.720E-03 BA-140 4.700E+03 4.120E+00 0.OOOE+00 1.340E+00 2.460E+00 2.380E+03 0.OOOE+00 2.740E+02 BA-141 1.620E-11 9.050E-15 0.OOOE+00 7.830E-15 5.310E-14 9.210E-12 0.OOOE+00 5.260E-13 BA-142 1.800E-20 1.300E-23 0.OOOE+00 1.050E-23 7.630E-24 2.350E-22 0.OOOE+00 1.010E-21' LA-140 4.780E-01 1.670E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.650E+03 0.OOOE+00 5.630E-02 LA-142 1.640E-04 5.210E-05 0.000E+00 0.000E+00 0.000E+00 1.030E+01 0.000E+00 1.630E-05 CE-141 2.280E+00 1.140E+00 0.000E+00 4.990E-01 0.OOOE+00 1.420E+03 0.OOOE+00 1.690E-01 CE-143 3.160E-01 1.710E+02 0.OOOE+00 7.180E-02 0.OOOE+00 2.510E+03 0.OOOE+00 2.480E-02 CE-144 1.210E+02 3.790E+01 0.OOOE+00 2.100E+01 0.OOOE+00 9.870E+03 0.000E+00 6.450E+00 PR-143 2.230E+00 6.690E-01 0.000E+00 3.620E-01 0.OOOE+00 2.400E+03 0.OOOE+00 1.1 1OE-01 PR-144 2.200E-15 6.800E-161 0.OOOE+00 3.600E-16 0.OOOE+00 1.460E-12 0.OOOE+00 1.11OE-16 ND-147 1.570E+00 1.270E+00 0.OOOE+00 6.990E-01 0.OOOE+00 2.020E+03 0.OOOE+00 9.860E-02 W-187 1.760E+01 1.040E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.460E+03 0.OOOE+00 4.680E+00 NP-239 2.630E-01 1.890E-02 0.OOOE+00 5.470E-02 0.OOOE+00 1.400E+03 0.OOOE+00 1.330E-02 I

Appendix E Ai Child Water - Page 3 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

I January, 2010 Revision 52 APPENDIX E Ai Child Dose Factors for use in the Liquid Dose Calculations Agegroup:

CHILD Pathway:

Fresh Water Fish - Sport (FFSP)

Units:".

mrem/hr / jxCi/ml Nuclide Bone Liver Thyroid Kidney Lung Gilli.

Skin Total Body H-3 O.OOOE+00 1.440E-01 1.440E-01 1.440E-01 1.440E-01 1.440E-01 0.OOOE+00 1.440E-01 C-14 4.380E+04 8.760E+03 8.760E+03 8.760E+03 8.760E+03 8.760E+03 0.OOOE+00 8.760E+03 NA-24 1.510E+02 1.510E+02 1.510E+02 1.510E+02 1.510E+02 1.510E+02 0.000E+00 1.510E+02 P-32 1.850E+06 8.680E+04 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.130E+04 0.OOOE+00 7.150E+04 CR-51 0.OOOE+00 0.OOOE+00 7.580E-01 2.070E-01 1.380E+00 7.240E+O1 0.000E+00 1.370E+00 MIN-54 0.OOOE+00 3.360E+03 0.OOOE+00 9.420E+02 0.OOOE+00 2.820E+03 0.OOOE+00 8.950E+02 MN-56 0.OOOE+00 1.650E-01 0.OOOE+00 2.OOOE-01 0.OOOE+00 2.400E+01 0.OOOE+00 3.730E-02 FE-55 9.040E+02 4.790E+02 0.OOOE+00 0.OOOE+00 2.710E+02 8.880E+01 0.OOOE+00 1.490E+02 FE-59 1.280E+03 2.070E+03 0.OOOE+00 0.OOOE+00 5.990E+02 2.150E+03 0.OOOE+00 1.030E+03 CO-58 0.OOOE+00 7.010E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.090E+02 0.OOOE+00 2.150E+02 CO-60 0.OOOE+00 2.080E+02 0.000E+00 0.OOOE+00 0.000E+00 1.150E+03 0.OOOE+00 6.130E+02 NI 4.230E+04 2.270E+03 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.530E+02 0.OOOE+00 1.440E+03 NI-65 2.370E-01 2.230E-02 0.000E+00 0.OOOE+00 0.000E+00 2.740E+00 0.OOOE+00 1.300E-02 CU-64 0.000E+00 2.590E+00 0.OOOE+00 6.260E+00 0.000E+00 1.220E+02 0.OOOE+00 1.570E+00 ZN-65 2.150E+04 5.730E+04 0.000E+00 3.610E+04 0.OOOE+00 1.010E+04 0.000E+00 3.560E+04 ZN-69 1.080E-06 1.560E-06 0.OOOE+00 9.470E-07 0.OOOE+00 9.840E-05 0.OOOE+00 1.440E-07 BR-83 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.340E-02 BR-84 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.570E-12 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RB-86 0.OOOE+00 1.020E+05 0.000E+00 0.OOOE+00 0.OOOE+00 6.530E+03 0.OOOE+00 6.250E+04 RB-88 0.OOOE+00 1.330E-22 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.5 1OE-24 0.OOOE+00 9.220E-23 RB-89 0.OOOE+00 1.580E-26 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.370E-28 0.000E+00

'1.400E-26 SR-89 3.070E+04 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 1.190E+03 0.OOOE+00 8.780E+02 SR-90 4.010E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.400E+03 0.OOOE+00 1.020E+05 SR-91 9.800E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 2.160E+02 0.OOOE+00 3.700E+00 Appendix E Ai Child Fish - Page 1 of 3 0 j

0 January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX E Ai Child Dose Factors for use in the Liquid Dose Calculations Agegroupi:

CHILD Pathway:

Fresh Water Fish - Sport (FFSP) units:

mrem/hr gCi/mI Nuclide 1B3n"'

Liver 2

Thyroid Kidney

§ Lung Giili U>

USkiin 2 ToI'B6d; SR-92 4.580E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 8.670E+00 0.OOOE+00 1.840E-02 Y-90 6.240E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.780E+03 0.OOOE+00 1.670E-02 Y-91 1.170E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.560E+03 0.000E+00 3.130E-01 Y-91M 1.480E-11 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.900E-08 0.OOOE+00 5.390E-13 Y-92 6.440E-04 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+06 1.860E+01 0.OOOE+00 1.840E-05 Y-93 4.300E-02 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.420E+02 0.OOOE+00
1. 180E-03 ZR-95 2.980E-01 6.550E-02 0.OOOE+00 9.370E-02 0.OOOE+00 6.830E+01 0.OOOE+00 5.830E-02 ZR-97 6.780E-03 9.790E-04 0.OOOE+00 1.410E-03 0.000E+00 1.480E+,02 0.OOOE+00 5.780E-04 NB-95 5.210E+02 2.030E+02 0.OOOE+00 1.900E+02 0.OOOE+00 3.750E+05 0.OOOE+00 1.450E+02 MO-99 0.OOOE+00 8.130E+01 0.OOOE+00 1.740E+02 0.OOOE+00 6.720E+01 0.OOOE+00 2.010E+01 TC-99M 6.860E-04 1.350E-03 0.OOOE+00 1.950E-02 6.830E-04 7.650E-01 0.OOOE+00 2.230E-02 TC-101 3.610E-33 3.780E-33 0.OOOE+00 6.440E-32 2.OOOE-33 1.200E-32 0.OOOE+00 4.790E-32 RU-103 5.650E+001-0.OOOE+00.

0.OOOE+00 1.420E+01 0.OOOE+00 1.460E+02 0.OOOE+00 2.170E+00?

RU-105 1.190E-02 0.OOOE+00 0.OOOE+00 1.050E-01 0.OOOE+00 7.790E+00 "0.OOOE+00 4.330E-03 RU-106 9.190E+01 0.600E+00 0.OOOE+00 1.240E+02 0.OOOE+00 1.430E+03 0.OOOE+00 1.150E+01 AG-110M 9.720E-01 6.570E-01 0.000E+00 1.220E+00 0.OOOE+00 7.810E+01 0.OOOE+00 5.250E-01 TE-125M 3.540E+03 9.610E+02 9.950E+02 0.OOOE+00 O.OOOE+00 3.420E+03 0.OOOE+00 4.730E+02 TE-127 2.520E+01 6.800E+00 1.750E+01 7.170E+01 0.OOOE+00 9.850E+02 0.OOOE+00 5.410E+00 TE-127M 9.040E+03 2.430E+03 2.160E+03 2.580E+04 0.000E+00, 7.320E+03 0.OOOE+00 1.070E+03 TE-129 2.280E-05 6.370E-06 1.630E-05 6.680E-05 0.000E+00 1.420E-03 0.000E+00 5.420E-06 TE-129M 1.500E+04 4.190E+03 4'840E+03 4.41 OE+04 0.OOOE+00 1.830E+04 0.OOOE+00 2.330E+03 TE-131 1.210E-16 3.680E-17 9.220E-17 3.650E-16 0.OOOE+00 6.330E-16 0.000E+00 3.590E-17 TE-131M 1.300E+03 4.500E+02 9.250E+02 4.350E+03 0.OOOE+00 1.820E+04 0.OOOE+00 4.790E+02 TE-132 2.570E+03 1.140E+03 1.650E+03 1.050E+04 0.OOOE+00 1.140E+04 0.OOOE+00 1.370E+03 1-130 8.950E+00 1.810E+01 1.990E+03 2.700E+01 0.OOOE+00 8.460E+00 0.OOOE+00 9.320E+00 Appendix E Ai Child Fish - Page 2 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX E Ai Child Dose Factors for use in the Liquid Dose Calculations Agegroup:

CHILD Pathway:

Fresh Water Fish - Sport (FFSP)

Units:

mrem/hr / gCi/ml

~Nueidid jBone~

Liver ;

~Thyroid Kidney LAng

>Gilli

>Skin~

TotatBody

., ;*:*,Y

  • F resh

............i.&S o t( FP-.....

1-131 1.860E+02 1.870E+02 6.190E+04 3.070E+02 0.OOOE+00 1.670E+01 0.OOOE+00 1.060E+02 1-132 6.830E-03 1.250E-02 5.820E-01 1.920E-02 0.OOOE+00 1.480E-02 0.000E+00 5.770E-03 1-133 3.140E+0 1 3.880E+01 7.21 OE+03 6.470E+01 0.OOOE+00.

1.560E+01 0.OOOE+00 1.470E+01 1-134 2.750E-08 5.100E-08 1.170E-06 7.800E-08 0.OOOE+00 3.380E-08 0.OOOE+00 2.350E-08 1-135 1.670E+00 3.010E+00 2.660E+02 4.610E+00 0.OOOE+00 2.290E+00 0.000E+00 1.420E+00 CS-134 3.680E+05 6.040E+05 0.OOOE+00 1.870E+05 6.710E+04 3.250E+03 0.000E+00 1.270E+05 CS-136 3.51OE+04 9.640E+04 0.000E+00 5.130E+04 7.660E+03 3.390E+03 0.OOOE+00 6.240E+04 CS-137 5.140E+05 4.920E+05 0.OOOE+00 1.600E+05 5.770E+04 3.080E+03 0.000E+00 7.270E+04 CS-138 1.210E-11 1.690E-1 1 0.OOOE+00

1. 190E-1 1 1.280E-12 7.770E-12 0.OOOE+00 1.070E-11 BA-139 7.930E-06 4.230E-09 0.000E+00 3.700E-09 2.490E-09 4.580E-04 0.OOOE+00 2.300E-07 BA-140 2.480E+02 2.170E-01 0.OOOE+00

.7.060E-02 1.290E-01 1.250E+02 0.OOOE+00 1,450E+01 BA-141 1.210E-24 6.800E-28 0.OOOE+00 5.880E-28 3.990E-27 6.920tE-25 0.OOOE+00 3.950E-26 BA-142 3.460E-42 2.490E-45 0.OOOE+00 2.020E-45 1.470E-45 4.510E-44 0.OOOE+00 1.930E-43 LA-140 1.310E-01 4.590E-02 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.280E+03 0.OOOE+00 1.550E-02 LA-142 2.970E-07 9.470E-08 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.880E-02 0.OOOE+00 2.960E-08 CE-141 3.060E-02 1.520E-02 0.OOOE+00 6.680E-03 0.OOOE+00 1.900E+01 0.OOOE+00 2.260E-03 CE-143 3.320E-03 1.800E+00 0.OOOE+00 7.550E-04 0.000E+0O 2.640E+01 0.OOOE+00 2.610E-04 CE-144 1.630E+00 5.120E-01 0.OOOE+00 2.836E-01 0.OOOE+00 1.330E+02 0.000E+00 8.710E-02 PR-143 7.340E-01 2.200E-01 0.OOOE+00 1.190E-01 0.OOOE+00 7.920E+02 0.OOOE+00 3.640E-02 PR-144 2.180E-28 6.750E-29 0.OOOE+00 3.570E-29 0.OOOE+00 1.450E-25 0.OOOE+00 1.100E-29 ND-147 5.150E-01 4.170E-01 0.OOOE+00 2.290E-01 0.OOOE+00 6.610E+02 0.OOOE+00 31230E-02 W-187 2.016E+02 1.190E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.680E+04

.0.000E+00 5.350E+01 NP-239 3.080E-02 2.210E-03 0.OOOE+00 6.390E-03 0.OOOE+00 1.630E+02 0.OOOE+00 1.550E-03 Appendix E Ai Child Fish - Page 3 of 3 0

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

S January, 2010 Revision 52 APPENDIX E Ai Child Dose Factors for use in the Liquid Dose Calculations Agegroup:

CHILD Pathway:

Shoreline Sediment (SHDp)

Units:

mrem/hr / jtCi/ml Nuclide-

<BnLiver I

Thyrid,-

kifdney

~

Lung2 Gillij I

K kin9 Total I~dy~

H-3 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 C-14 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00 0.000E+00 NA-24 7.480E-01 7.480E-01 7.480E-01 7.480E-01 7.480E-01 7.480E-01 8.680E-01 7.480E-01 P-32 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 CR-5 1 2.920E-01 2.920E-01 2.920E-01 2.920E-01 2.920E-01 2.920E-01 3.450E-01 2.920E-01 MN-54 8.680E+01 8.680E+01 8.680E+01 8.680E+01 8.680E+01 8.680E+01 1.020E+02 8.680E+01 MN-56 5.650E-02 5.650E-02 5.650E-02 5.650E-02 5.650E-02 5.650E-02 6.680E-02 5.650E-02 FE-55 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 FE-59 1.710E+01 1,.710E+01 1.710E+01 1.710E+01 1.710E+01 1.710E+01 2.010E+01 1.710E+01 CO-58 2.370E+01 2.370E+01 2.370E+01 2.370E+01 2.370E+01 2.370E+01 2.780E+01 2.370E+01 CO-60 1.350E+03 1.350E+03 1.350E+03 1.350E+03 1.350E+03 1.350E+03 1.580E+03 1.350E+03 NI-63 0.OOOE+00 0.OOOE+00

+00 0.00E+00 0.000E+00 0.000E+00 0.000E+00 0.OOOE+00 NI-65 1.860E-02 1.860E-02 i.860E-02 1.860E-02 1.860E-02 1.860E-02 2.160E-02 1.860E-02r/

CU-64 3.800E-02 3.800E-02 3.800E-02 3.800E-02 3.800E-02

'3.800E-02 4.3 1OE-02 3.800E-02 ZN-65 4.680E+01 4.680E+01 4.680E+01 4.680E+01 4.680E+01 4.680E+01 5.380E+01 4.680E+01 ZN-69 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 BR-83 3.050E-04 3.050E-04 3.050E-04 3.050E-04 3.050E-04 3.050E-04 4.430E-04 3.050E-04 BR-84 1.270E-02 1.270E-02 1.270E-02 1.270E-02 1.270E-02 1.270E-02 1.480E-02 1.270E-02 BR-85 0.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 "

0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RB-86 5.630E-01 5.630E-01 5.630E-01 5.630E-01 5.630E-01 5.630E-01 6.430E-01 5.630E-01 RB-88 2.070E-03 2.070E-03 2.070E-03 2.070E-03 2.070E-03 2.070E-03 2.370E-03 2.070E-03 RB-89 7.700E-03 7.700E-03 7.700E-03 7.700E-03 7.700E-03 7.700E 9.240E 7.700E-03 SR-89 1.360E-03 1.360E-03 1.360E-03 1.360E-03 1.360E-03 1.360E-03 1.570E-03 1.360E-03 SR-90 0.OOOE+00 0.OOOE+00 0.OOOE+/-00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 SR-91 1.350E-01 1.350E-01 1.350E-01 1.350E-01 1.350E-01 1.350E-01 1.570E-01 1.350E-01 Appendix E Ai Child Shoreline Sediment - Page 1 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX E Ai Child Dose Factors for use in the Liquid Dose Calculations Agegroup:

CHILD Pathway:

Shoreline Sediment (SHDp)

UnitS:

mrem/hr / tCi/ml Nuclide

-Bone,ý Liver Thyrroid Kidney 5Lqng iGilli Skin Total Býodyý SR-92 4.860E-02 4.860E-02 4.860E-02 4.860E-02 4.860E-02 4.860E-02 5.410E-02 4.860E-02 Y-90 2.810E-04 2.810E-04 2.810E-04 2.810E-04 2.810E-04 2.810E-04 3.320E-04 2.810E-04 Y-91 6.720E-02 6.720E-02 6.720E-02 6.720E-02 6.720E-02 6.720E-02 7.560E-02 6.720E-02 Y-91M 6.280E-03 6.28.OE-03 6.280E-03 6.280E-03 6.280E-03 6.280E-03 7.270E-03 6.280E-03 Y-92 1.130E-02 1.130E-02 1.130E-02 1.130E-02 1.130E-02 1.130E-02

.1.340E-02 1.130E-02 Y-93 1.150E-02 1.150E-02 1.150E-02 1.150E-02 1.150E-02 1.150E-02 1.570E-02 1.150E-02 ZR-95 1.530E+01 1.530E+01 1.530E+01 1.530E+01 1.530E+01 1.530E+01 1.780E+01 1.530E+01 ZR-97 1.850E-01 1.850E-01 1.850E-01 1.850E-01 1.850E-01 1.850E-01 2.160E-01 1.850E-01 NB-95 8.560E+00 8.560E+00 8.560E+00 8.560E+00 8.560E+00 8.560E+00 1.010E+01 8.560E+00 MO-99 2.500E-01 2.500E-01 2.500E-01 2.500E-01 2.500E-01 2.500E-01 2.900E-01 2.500E-01 TC-99M 1.150E-02 1.150E-02 1.150E-02 1.150E-02 1.150E-02 1.150E-02 1.320E-02 1.150E-02 TC-101 1.270E-03 1.270E-03 1.270E-03 1.270E-03 1.270E-03 1.270E-03 1.420E-03 1.270E-03 RU-103 6.780E+00 6.780E+00 6.780E+00 6.780E+00 6.780E+00 6.780E+00 7.910E+00 6.780E+00 RU-105 3,990E-02 3.990E-02 3.990E-02 3.990E-02 3.990E-02 3.990E-02 4.520E-02 3.990E-02 RU-106 2.640E+0 I 2.640E+01 2.640E+01 2.640E+0 1 2.640E+01 2.640E+01 3.170E+01 2.640E+01 AG-110M 2.150E+02 2.150E+02 2.150E+02 2.150E+02 2.150E+02 2.150E+02 2.510E+02 2.150E+02 TE-125M 9.720E-02 9.720E-02 9.720E-02 9.720E-02 9.720E-02 9.720E-02 1.330E-01 9.720E-02 TE-127 1.860E-04 1.860E-04 1.860E-04 1.860E-04 1.860E-04 1.860E-04 2.050E-04 1.860E-04 TE-127M 5.740E-03 5.740E-03 5.740E-03 5.740E-03 5.740E-03 5.740E-03 6.780E-03 5.740E-03 TE-129 1.640E-03 1.640E-03 1.640E-03 1.640E-03 1.640E-03 1.640E-03 1.940E-03 1.640E-03 TE-129M 1.240E+00 1.240E+00 1.240E+00 1.240E+00 1.240E+00 i.240E+00 1.450E+00 1.240E+00 TE-131 1.830E-03 1.830E-03 1.830E-03 1.830E-03 1.830E-03 1.830E-03 2.160E+00 1.830E-03 TE-131M 5.030E-0I 5.030E-01 5.030E-01 5.030E-01 5.030E-01 5.030E-01 5.920E-01 5.030E-01 TE-132 2.650E-01 2.650E-01 2.650E-01 2.650E-01 2.650E-01 2.650E-01 3.120E-01 2.650E-01 1-130 3.450E-01 3.450E-01 3.450E-01 3.450E-01 3.450E-01 3.450E-01 4.190E-01 3.450E-01 Appendix E Ai Child Shoreline Sediment - Page 2 of 3

S S

January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX E Ai Child Dose Factors for use in the Liquid Dose Calculations Agegroup:

CHILD Pathw'ay:

Shoreline Sediment (SHDp)

Units:

mrem/hr / tCi/ml

-Nuclide,

'Bonex.ý

... Liver*

Thyroid Kidniey Lung*

.. Gilii

' Skht

'Total Body 1-131 1.080E+00 1.080E+00 1.080E+00 1.080E+00 1.080E+00 1.080E+00 1.310E+00 1.080E+00 1-132 7.800E-02 7.800E-02 7.800E-02 7.800E-02 7.800E-02 7.800E-02 9.180E-02 7.800E-02 1-133 1.540E-01 1.540E-01 1.540E-01 1.540E-01 1.540E-01 1.540E-01 1.870E-01 1.540E-01 1-134 2.800E-02 2.800E-02 2.800E-02 2.800E-02 2.800E-02 2:800E-02 3.320E-02 2.800E-02 1-135 1.580E-01 1.580E-01 1.580E-01 1.580E-01 1.580E-01 1.580E-01 1.850E-01 1.580E-01 CS-134 4.300E+02 4.300E+02 4.300E+02 4.300E+02 4.300E+02 4.300E+02 5.010E+02 4.300E+02 CS-136 9.450E+00 9.450E+00 9.450E+00 9.450E+00 9.450E+00 9.450E+00 1.070E+01 9.450E+00 CS-137 6.440E+02 6.440E+02 6.440E+02 6.440E+02 6.440E+02 6.440E+02 7.5 1OE+02 6.440E+02 CS-138 2.250E-02 2.250E-02 2.250E-02 2.250E-02 2.250E-02 2.250E-02 2.570E-02 2.250E-02 BA-139 6.630E-03 6.630E-03 6.630E-03 6.630E-03 6.630E-03 6.630E&03 7.460E-03 6.630E-03 BA-140 1.290E+00 1.290E+00 1.290E+00 1.290E+00 1.290E+00 1.290E+00 1.470E+00 1.290E+00 BA-141 2.610E-03 2.610E-03 2.610E-03 2.610E-03 2.610E-03 2.610E-03 2.980E-03 2.610E-03 BA:142 2.810E-03 2.810E-03 2.810E-03 2.810E-03 2.810E-03 2.810E-03 3.200E-03 2.810E-03-"-

LA-140 1.200E+00 1.200E+00 1.200E+00 1.200E+00 1.200E+00 1.200E+00 1.360E+00 1.200E+00 LA-142 4.760E-02 4.760E-02 4.760E-02 4.760E-02 4.760E-02 4.760E-02 5.710E-02 4.760E-02 CE-141 8.560E-01 8.560E-01 8.560E-01 8.560E-01 8.560E-01 8.560E-01 9.650E-01 8.560E-01 CE-143 1.450E-01 1.450E-01 1.450E-01 1.450E-01 1.450E-01 1.450E-01 1.650E-01 1.450E-01 CE-144 4.350E+00 4.350E+00 4.350E+00 4.350E+00 4.350E+00 4.350E+00 5.040E+00 4.350E+00 PR-143 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 0.OOOE+00 PR-144 1.150E-04 1.150E-04 1150E-04 1.150E-04 1.150E-04 1.150E-04 1.320E-04 1.150E-04 ND-147 5.260E-0 1 5.260E-0 1 5.260E-01 5.260E-01 5.260E-01 5.260E-01 6.31E-0 1 5.260E-0 1 W-187 1.470E-01 1.470E-01 1.470E-01 1.470E-01 1.470E-01 1.470E-01 1.710E-01 1.470E-01 NP-239 1.070E-01 1.070E-01 1.070E-01 1.070E-01 1.070E-01 1.070E-01 1.240E-01 1.070E-01 A

Appendix E Ai Child Shoreline Sediment - Page 3 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX F Ai Infant Dose Factors for use in the Liquid Dose Calculations AgegrouP:

INFANT

  • Pathway:

Potable Water (PWtr) ln ni:

mrem/hr / tCi/mI Nuclide Bone Liver Thyroid RKidney Lung Gilli Skin -

Total Body H-3 0.OOOE+00 1.160E+01 1.160E+01 1.160E+01 1.160E+01 1.160E+01 0.OOOE+00 1.160E+01 C-14 8.920E+02 1.900E+02 1.900E+02 1.900E+02 1.900E+02 1.900E+02 0.OOOE+00 1.900E+02 NA-24 2.190E+02 2.190E+02 2.190E+02 2,190E+02 2.190E+02 2.190E+02 0.OOOE+00 2.190E+02 P-32 6.240E+04 3.670E+03 0.OOOE+00 0.OOOE+00 0.OOOE+00 8.450E+02 0.OOOE+00 2.420E+03 CR-51 0.OOOE+00 O.OOOE+00 3.420E-01 7.470E-02 6.650E-01 1.530E+01 0.OOOE+00 5.240E-01 MN-54 0.OOOE+00 7.480E+02 O.OOOE+00 1.660E+02 0.OOOE+00 2.750E+02 0.OOOE+00 1.690E+02 MN-56 0.OOOE+00 1.220E+00 0.OOOE+00 1.050E+00 0.OOOE+00 1.11OE+02 0.000E+00 2.100E-01 FE-55 5.230E+02 3.380E+02 0.OOOE+00 0.OOOE+00 1.650E+02 4.290E+01

.0.OOOE+00 9.030E+01 FE-59 1.150E+03 2.010E+03 0.OOOE+00 0.OOOE+00 5.940E+02 9.590E+02 0.OOOE+00 7.910E+02 CO-58 0.OOOE+00 1.350E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.360E+02 0.000E+00 3.360E+02 CO-60 0.OOOE+00 4.060E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 9.670E+02 0.OOOE+00 9.590E+02 NI-63 2.390E+04 1.470E+03 0.OOOE+00 0.OOOE+00 0.OOOE+00 7.340E+01 0.OOOE+00 8.280E+02 NI-65 6.520E+00 7.380E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.620E+01 0.OOOE+00 3.360E-01 CU-64 0.OOOE+00 1.190E+01 0.OOOE+00 2.010E+01 0.OOOE+00 2.440E+02 0.OOOE+00 5.500E+00 ZN-65 6.910E+02 2.370E+03 0.OOOE+00 1.150E+03 0.OOOE+00 2.OOOE+03 0.OOOE+00 1.090E+03 ZN-69 4.390E-04 7.910E-04 0.OOOE+00 3.290E-04 0.OOOE+00 6.450E-02 0.OOOE+00 5.890E-05 BR-83 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.200E-01 BR-84 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00 2.220E-06 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.800E-76 RB-86 0.OOOE+00 6.280E+03 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.610E+02 0.OOOE+00 3.100E+03 RB-88 0.OOOE+00 1.250E-1 1 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.220E-11 0.OOOE+00 6.840E-12 RB-89 0.OOOE+00 9.960E-14 0.000E+00 0.OOOE+00 0.OOOE+00 3.390E-14 0.OOOE+00 6.860E-14 SR-89 9.380E+04 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.930E+03 0.OOOEtOO 2.690E+03 SR-90 6.960E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 8.690E+03 0.000E+00 1.770E+05 SR-91 7.830E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 9.270E+02 0.OOOE+00 2.830E+01 Appendix F Ai Infant Water - Page I of 3

-j

'01

0 January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX F Ai Infant Dose Factors for use in the Liquid Dose Calculations Agegroup:

INFANT

.Patfiway:

Potable Water (PWtr)

Units:'

mrem/hr / ýLCi/ml

.Nuclide 9B0ne Liver Thyroid Kidniey Lungk Gilli 2

'Skini-

^"Total Body-SR-92 3.350E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.610E+02 0.OOOE+00 1.240E+00 Y-90.

2.870E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.970E+03 0.OOOE+00 7.700E-02 Y-91 4.230E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 3.030E+03 0.OOOE+00 1.130E+00 Y-91M 1.350E-06 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.510E-03 0.OOOE+00 4.610E-08 Y-92 2.740E-02 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.240E+02 0.OOOE+00 7.710E-04 Y-93 4.010E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.170E+03 0.OOOE+00 1.090E-02 ZR-95 7.710E+00 1.880E+00 0.OOOE+00 2.020E+00 0.000E+00 9.350E+02 0.OOOE+00 1.330E+00 ZR-97 3.400E-01 5.840E-02 0.OOOE+00 5.890E-02 0.OOOE+00 3.720E+03 0.OOOE+00 2.670E-02 NB-95 1.560E+00 6.440E-01 0.OOOE+00 4.620E-01 0.OOOE+-00 5.440E+02 0.OOOE+00 3.720E-01 MO-99 0.OOOE+00 1.130E+03 0.OOOE+00 1.680E+03 0.OOOE+00 3.710E+02 0.000E+00 2.200E+02 TC-99M

.1.810E-02 3.740E-02 0.OOOE+00 4.020E-01 1.950E-02 1.090E+01 0.OOOE+00 4.820E-01 TC-101 4.570E-17 5.750E-17 O.OOOE+00 6.840E-16 3.140E-17 9.780E-15 0.OOOE+00 5.690E-16 RU-103 5.520E+01 0.000E+00 0.OOOE+00 1.150E+02 0.OOOE+00 6.710E+02 0.OOOE+00 1.850E+01 RU-105 7.850E-01 0.OOOE+00 0.OOOE+00 5.770E+00 0.OOOE+00 3.120E+02 0.OOOE+00 2.640E-01 RU-106 9.060E+02 0.OOOE+00 0.OOOE+00 1.070E+03 0.OOOE+00 6.880E+03 0.OOOE+00 1.130E+02 AG-110M 3.740E+01 2.730E+01 0.OOOE+00 3.910E+01 0.000E+00 1.420E+03 0.OOOE+00 1.810E+01 TE-125M 8.710E+02 2.910E+02 2.930E+02 0.OOOE+00 0.OOOE+00 4.150E+02 0.OOOE+00 1.180E+02 TE-127 1.550E+01 5.200E+00 1.260E+01 3.790E+01 0.OOOE+00 3.260E+02 0.OOOE+00 3.340E+00 TE-127M 2.190E+03 7.280E+02 6340E+02 5.400E+03 0.OOOE+00 8.850E+02 0.OOOE+00 2.660E+02 TE-129 7.860E-03

-2.710E-03 6.590E-03 1.960E-02 0.000E+00 6.280E-01 0.OOOE+00 1.840E-03 TE-129M 3.720E+03 1.280E+03 1.430E+03 9.310E+03 0.OOOE+00 2.220E+03 0.OOOE+00 5.730E+02 TE-131 1.420E-08 5.250E-09 1.270E-08 3.640E-08 0.OOOE+00 5.750E-07 0.OOOE+00 3.990E-09 TE-131M 4.330E+02 1.740E+02 3.540E+02 1.200E+03 0.OOOE+00 2.940E+03 0.OOOE+00 1.440E+02 TE-132 7.030E+02 3.480E+02 5.140E+02 2.180E+03 0.OOOE+00 1.290E+03 0.0O0E+00 3.250E+02 1-130 1.150E+02 2.530E+02 2.840E+04 2.780E+02 0.000E+00 5.430E+01 0.OOOE+00 1.020E+02 Appendix F Ai Infant Water - Page 2 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX F Ai Infant Dose Factors for use in the Liquid Dose Calculations

. Agegroup:

INFANT Pathway:

Potable Water (PWtr)

Units:,ý mrem/hr / j, Ci/ml Nuclide iBone Liver Thyroid.:

Kidney.

Lung i.

Gilli Skin Total Body 1-131 1.290E+03 1.520E+03 5.010E+05 1.780E+03 0.OOOE+00 5.440E+01 0.OOOE+00 6.700E+02 1-132 1.680E+00 3.410E+00 1.600E+02 3.800E+00 0.OOOE+00 2.760E+00 0.OOOE+00 1.210E+00 1-133 3.150E+02 4.590E+02 8.350E+04 5.400E+02 0.OOOE+00 7.770E+01 0.OOOE+00 1.340E+02 1-134 2.440E-03 4.990E-03 1.160E-01 5.580E-03 0.OOOE+00 5.160E-03 0.OOOE+00 1.780E-03 1-135 3.900E+01 7.750E+01 6.950E+03 8.640E+0 1 0.OOOE+00 2.800E+01 0.OOOE+00 2.830E+01 CS-134 1.420E+04 2.640E+04 0.OOOE+00 6.810E+03 2.790E+03 7.180E+01 0.OOOE+00 2.670E+03 CS-136 1.680E+03 4.950E+03 0.OOOE+00 1.970E+03 4.030E+02 7.510E+01.

0.OOOE+00 1.850E+03 CS-137 1.960E+04 2.300E+04 0.OOOE+00 6.170E+03 2.500E+03 7.190E+01 0.OOOE+00 1.630E+03 CS-138 3.330E-06 5.410E-06 0.OOOE+00 2.700E-06 4.210E-07 8.650E-06 0.OOOE+00 2.620E-06 BA-139 8.180E-02 5.420E-05 0.OOOE+00 3.260E-05 3.290E-05 5.180E+00 0.000E+00 2.370E-03 BA-140 6.260E+03 6.260E+00 0.OOOE+00 1.490E+00 3.840E+00 1.540E+03 0.OOOE+00 3.230E+02 BA-141 2.220E-1 1 1.520E-14 0.OOOE+00 9.140E-15 9.250E-15 2.710E-10 0.OOOE+00 7.000E-13 BA-142 2.460E-20 2.040E-23 0.000E+00 1.180E-23 1.240E-23 1.010E-19 0.OOOE+00 1.210E-21 LA-140 6.460E-01 2.550E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.990E+03 0.OOOE+00 6.550E-02 LA-142 2.220E-04 8.160E-05 0.000E+00 0.OOOE+00 0.OOOE+00 1.390E+01 0.OOOE+00 1.950E-05 CE-141 2.930E+00 1.790E+00 0.OOOE+00 5.510E-01 0.OOOE+00 9.230E+02 0.OOOE+00 2.100E-01 CE-143 4.330E-01 2.870E+02 0.OOOE+00 8.360E-02 0.OOOE+00 1.670E+03 0.OOOE+00 3.270E-02 CE-144

1. 120E+02 4.580E+/-01 0.OOOE+00 1.850E+01 0.OOOE+00 6.430E+03 0.OOOE+00 6.270E+00 PR-143 2.980E+00 1.110E+00 0.OOOE+00 4.140E-01 0.OOOE+00 1.570E+03 0.OOOE+00 1.480E-01 PR-144 3.020E-15 1.170E-15 0.OOOE+00 4.240E-16 0.OOOE+00 5.440E-11 0.000E+00 1.520E-16 ND-147 2.020E+00 2.070E+00 0.OOOE+00 7.980E-01 0.OOOE+00 1.310E+03 0.000E+00 1.270E-01 W-187 2.400E+01 1.670E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 9.790E+02 0.OOOE+00 5.760E+00 NP-239 3.600E-01 3.220E-02 0.OOOE+00 6.430E-02 0.OOOE+00 9.320E+02 0.OOOE+00 1.820E-02 Appendix F Ai Infant Water - Page 3 of 3

0 0

January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX G Ri Adult Dose Factors for use in the Gaseous Dose Calculations

'Agegroup:

ADULT Pathway-Grs/Cow/Milk (CMILK)

Units:

m2-mrem/yr / ptCi/sec; C/3 mrem/yr

/

(m-3 Nuclide

- Bone Liver Thyroid

- Kidneyý

]Lung., -

Gilli Skin Total Body.

H-3 0.OOOE+00 7.630E+02 7.630E+02 7.630E+02 7.630E+02 7.630E+02 0.OOOE+00 7.630E+02 C-14 2.630E+08 5.270E+07 5.270E+07 5.270E+07 5.270E+07 5.270E+07 0.OOOE+00 5.270E+07 NA-24 2.440E+06 2.440E+06 2.440E+06 2.440E+06 2.440E+06 2.440E+06 0.OOOE+00 2.440E+06 P-32 1.710E+10 1.060E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.920E+09 0.OOOE+00 6.610E+08 CR-51 0.OOOE+00 0.OOOE+00 1.710E+04 6.300E+03 3.790E+04 7.190E+06 0.OOOE+00 2.860E+04.

MN-54 0.OOOE+00 8.410E+06 0.OOOE+00 2.500E+06 0.OOOE+00 2.580E+07 0.OOOE+00 1.610E+06 MN-56 0.OOOE+00 4.090E-03 0.OOOE+00 5.190E-03 0.OOOE+00 1.310E-01 0.OOOE+00 7.260E-04 FE-55 2.510E+07 1.740E+07 0.OOOE+00 0.OOOE+00 9.680E+06 9.950E+06 0.OOOE+00 4.050E+06 FE-59 2.970E+07 6.980E+07 0.OOOE+00 0.OOOE+00 1.950E+07 2.330E+08 0.OOOE+00 2.680E+07 CO-58 0.OOOE+00 4.710E+06 0.OOOE+00 0.OOOE+00 0.OOOE+00 9.550E+07 0.OOOE+00 1.060E+07 CO-60 0.000E+00 1.640E+07 0.OOOE+00 0.000E+00 0.OOOE+00 3.080E+08 0.OOOE+00 3.620E+07 NI-63 6.730E+09 4.660E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 9.730E+07 0.OOOE+00 2.260E+08 NI-65 3.700E-01 4.810E-02 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.220E+00 0.OOOE+00 2.190E-02 CU-64 0.OOOE+00 2.380E+04 0.OOOE+00 6.010E+04 0.OOOE+00 2.030E+06 0.OOOE+00 1.120E+04.

ZN-65 1.370E+09 4.370E+09 0.OOOE+00 2.920E+09 0.000E+00 2.750E+09 0.OOOE+00 1.970E+09 ZN-69 2.090E-12 4.OOOE-12 0.OOOE+00 2.600E-12 0.OOOE+00 6.010E-13 0.OOOE+00 2.780E-13 BR-83 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.400E-01 0.000E+00 9.720E-02 BR-84 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.260E-28

.0003E+00 1.610E-23 BR-85 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 RB-86 0.OOOE+00 2.590E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.120E+08 0.000E+00 1.210E+09 RB-88 0.OOOE+00 2.140E-45 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.960E-56 O.OOOE+00 1.140E-45 RB-89 O.OOOE+00 4.330E-53 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.510E-66 0.000E+00 3.040E-53 SR-89 1.450E+09 0:OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.330E+08 0.OOOE+00 4.160E+07 SR-90 4.680E+10 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.350E+09 02000E+00 1.150E+10 SR-91 2.890E+04 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 1.380E+05 0.OOOE+00 1.170E+03 Appendix G Ri Adult Cow Milk - Page 1 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX G K Adult Dose Factors for use in the Gaseous Dose Calculations Agegroup:

ADULT Pathway:

Grs/Cow/Milk (CMILK)

Units:

m 2 mrem/yr / ýCi/sec;

_mrem/_r

/__Ci/m (H-3)

'Nuclide

- Bone Liver Thyroid Kidney Lung-Gilli Skin Total Body SR-92 4.880E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 9.680E+00 0.000E+00 2.11OE-02 Y-90 7.080E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 7.510E+05 0.OOOE+00 1.900E+00 Y-91 8.590E+03 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 4.730E+06 0.OOOE+00 2.300E+02 Y-91M 5.980E-20 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 1.760E-19 0.OOOE+00 2.320E-21 Y-92 5.580E-05 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 9.770E-01 0.OOOE+00 1.630E-06 Y-93 2.230E-01 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 7.090E+03 0.OOOE+00 6.170E-03 ZR-95 9.430E+02 3.030E+02 0.OOOE+00 4.750E+02 0.OOOE+00 9.590E+05 0.OOOE+00 2.050E+02 ZR-97 4.330E-01 8.740E-02 0.000E+00 1.320E-01 0.OOOE+00 2.710E+04 0.OOOE+00 4.OOOE-02 NB-95 8.260E+04 4.590E+04 0.OOOE+00 4.540E+04 0.OOOE+00 2.790E+08 0.OOOE+00 2.470E+04 MO-99 0.OOOE+00 2.480E+07 0.OOOE+00 5.610E+07 0.OOOE+00 5.740E+07 0.OOOE+00 4.710E+06 TC-99M 3.320E+00 9.380E+00 0.OOOE+00 1.420E+02 4.600E+00 5.550E+03 0.OOOE+00 1.200E+02 TC-101 2.590E-60 3.740E-60 0.000E+00 6.730E-59 1.910E-60 1.120E-71 0.OOOE+00 3.670E-59 RU-103 1.020E+03 0.OOOE+00 0.OOOE+00 3.890E+03 0.OOOE+00 1.190E+05 0.OOOE+00 4.390E+02 RU-105 8.570E-04 0.OOOE+00 0.OOOE+00 1.11 OE-02 0.OOOE+00 5.240E-01 0.OOOE+00 3.380E-04 RU-106 2.040E+04 0.000E+00 0.OOOE+00 3.940E+04 0.000E+00 1.320E+06 0.OOOE+00 2.580E+03 AG-110M 5.820E+07 5.390E+07 0.OOOE+00 1.060E+08 0.OOOE+00 2.200E+10 0.OOOE+00 3.200E+07 TE-125M 1.630E+07 5.900E+06 4.900E+06 6.630E+07 0.OOOE+00 6.500E+07 0.OOOE+00 2.180E+06 TE-127 6.530E+02 2.340E+02 4.840E+02 2.660E+03 0.OOOE+00 5.150E+04 0.OOOE+00 1.410E+02 TE-127M 4.580E+07 1.640E+07 1.170E+07 1.860E+08 0.OOOE+00 1.540E+08 0.OOOE+00 5.580E+06 TE-129 2.830E-10 1.060E-10 2.170E-10 1.190E-09 0.000E+00 2.130E-10 0.OOOE+00 6.880E-11 TE-129M 6.020E+07 2.250E+07 2.070E+07 2.510E+08 0.000E+00 3.030E+08 0.OOOE+00 9.530E+06 TE-131 3.600E-33 1.500E-33 2.960E-33 1.580E-32 0.OOOE+00 5.100E-34 0.OOOE+00 1.140E-33 TE-131M 3.610E+05 1.770E+05 2.800E+05 1.790E+06 0.OOOE+00 1.750E+07 0.OOOE+00 1.470E+05 TE-132 2.400E+06 1.550E+06 1.720E+06 1.500E+07 0.OOOE+00 7.350E+07 0.OOOE+00 1.460E+06 1-130 4.200E+05 1.240E+06 1.050E+08 1.930E+06 0.OOOE+00 1.070E+06 O.OOOE+00 4.890E+05

=~(

Appendix G Ri Adult Cow Milk - Page 2 of 3 S

I 0

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX G Ri Adult Dose Factors for use in the Gaseous Dose Calculations 0

January, 2010 Revision 52

':Agegroup:

ADULT

  • Pathway:.

Grs/Cow/Milk (CMILK) tUjnits:

m 2 mrem/yr / jtCi/sec; C/3

.mrem_

_r (H-3)Ci/m 3

Nuclide..

Bone i

Liver Thyroid

-.RKidney, Lun:g Gilii Skin TotalBBody 1-131 2.960E+08 4.230E+08 1.390E+11 7.260E+08 0.OOOE+00 1.120E+08 0.OOOE+00 2.430E+08 1-132 1.640E-01 4.390E-01 1.540E+01 7.OOOE-01 0.OOOE+00 8.250E-02 0.OOOE+00 1.540E-01 1-133 3.870E+06 6.730E+06 9.890E+08 -

1.170E+07 0.OOOE+00 6.050E+06 0.OOOE+00 2.050E+06 1-134 2.020E-12 5.480E-12 9.490E-11 8.710E-12 0.OOOE+00 4.770E-15 0.OOOE+00 1.960E-12 1-135 1.280E+04 3.360E+04 2.220E+06 5.390E+04 0.OOOE+00 3.800E+04 0.OOOE+00 1.240E+04 CS-134 5.650E+09 1.350E+10 0.OOOE+00 4.350E+09 1.450E+09 2.350E+08 0.000E+00 1.100E+10 CS-136 2.630E+08 1.040E+09 0.OOOE+00 5.780E+08 7.930E+07 1.180E+08 0.OOOE+00 7.480E+08 CS-137 7.380E+09 1.010E+10 0.OOOE+00 3.430E+09 1.140E+09 1.950E+08 0.OOOE+00 6.610E+09 CS-138 9.050E-24 1.790E-23 0.OOOE+00 1.310E-23 1.300E-24 7.620E-29 0.OOOE+00 8.850E-24 BA-139 4.420E-08 3.150E-I1 0.OOOE+00 2.940E-11 1.790E-11.

7.830E-08 0.OOOE+00 1.290E-09 BA-140 2.690E+07 3.380E+04 0.060E+00 1.150E4-04 1.930E+04 5.530E+07 0.OOOE+00 1.760E+06 BA-141 4.090E-46 3.090E-49 0.OOOE+00 2.880E-49 1.760E-49 1.930E-55 0.OOOE+00 1.380E-47 BA-142 2.640E-80 2.720E-83 0.000E+00 2.300E-83 1.540E-83 3.720E-98 0.OOOE+00 1.660E-81 LA-140 4.510E+00 2.270E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.670E+05 0.OOOE+00 6.010E-01 LA-142 1.860E-11 8.460E-12 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.170E-08 0.OOOE+00 2.110E-12 CE-141 4.840E+03 3.280E+03 0.OOOE+00 1.520E+03 0.OOOE+00 1.250E+07 0.OOOE+00 3.720E+02 CE-143 4.160E+01 3.070E+04 0.OOOE+00 1.350E+01 0.OOOE+00 1.150E+06 0.OOOE+00 3.400E+00 CE-144 3.580E+05 1.500E+05 O.000E+00 8.870E+04 0.OOOE+00 1.210E+08 0.OOOE+00 1.920E+04 PR-143 1.580E+02 6.330E+01 0.OOOE+00 3.660E+01 0.000E+00 6.920E+05 0.OOOE+00 7.830E+00 PR-144 5.870E-54 2.440E-54 0.OOOE+00 1.380E-54 0.OOOE+00 8.450E-61 0.OOOE+00 2.990E-55 ND-147 9.420E+01 1.090E+02 0.OOOE+00 6.360E+01 0.000E+00 5.220E+05 0.OOOE+00 6.510E+00 W-187 6.510E+03 5.450E+03 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.780E+06 0.OOOE+00 1.900E+03 NP-239 3.670E+00 3.610E-01 0.OOOE+00 1.130E+00 0.OOOE+00 7.410E+04 0.000E+00 1.990E-01 Appendix G Ri Adult Cow Milk - Page 3 of 3

0 Catawba Nuclear Station

/

Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX G R1 Adult Dose Factors for use in the Gaseous Dose Calculations Agegroup:

ADULT Pathway:

Grs/Goat/Milk (GMILK) units:

mZ*mrem/yr /

Ci/sec; C/3 mrem/Ci/m3 (H-3)

Nuclide Bone Liver Thyroid Kidney' Lung Gilli Skin To'tal Body H-3 0.OOOE+00 1.560E+03 1.560E+03 1.560E+03 1.560E+03 1.560E+03 0.000E+00 1.560E+03 C-14 2.630E+08 5.270E+07 5.270E+07 5.270E+07 5.270E+07 5.270E+07 0.000E+00 5.270E+07 NA-24 2.930E+05 2.930E+05 2.930E+05 2.930E+05 2.930E+05 2.930E+05 0.000E+00 2.930E+05 P-32 2.050E+10 1.280E+09 0.OOOE+00 0.000E+00 0.000E+00 2.310E+09 0.000E+00 7.930E+08 CR-51 0.000E+00 0.000E+00 2.050E+03 7.550E+02 4.550E+03 8.620E+05 0.000E+00 3.430E+03 MN-54 0.000E+00 1.010E+06 0.OOOE+00 3.000E+05 0.OOOE+00 3.090E+06 0.OOOE+00 1.930E+05 MN-56 0.OOOE+00 4.910E-04 0.OOOE+00 6.230E-04 0.OOOE+00 1.570E-02 0.000E+00.

8.710E-05 FE-55 3.260E+05 2.260E+05 0.OOOE+00 0.OOOE+00 1.260E+05 1.290E+05 0.000E+00 5.260E+04 FE-59 3.860E+05 9.070E+05 0.000E+00 0.000E+ý00 2.540E+05 3.020E+06 0.000E+00 3.480E+05 CO-58 0.OOOE+00 5.660E+05 0.000E+00 0.OOOE+00 0.000E+00 1.150E+07 0.OOOE+00 1.270E+06 CO-60 0.OOOE+00 1.970E+06 0.000E+00 00OO0E+00 0.000E+00 3.700E+07 0.OOOE+00 4.340E+06 NI-63 8.070E+08 5.600E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.170E+07 0.000E+00 2.710E+07 NI-65 4.440E-02 5.770E-03 0.000E+00 0.000E+00 0.OOOE+00 1.460E-01 0.000E+00 2.630E-03 CU-64 0.000E+00 2.660E+03 0.000E+00 6.700E+03 0.OOOE+00 2.260E+05 0.000E+00 1.250E+03 ZN-65 1.650E+08 5.240E+08 0.000E+00 3.500E+08 0.OOOE+00 3.300E+08 0.000E+00 2.370E+08 ZN-69 2.510E-13 4.800E-13 0.000E+00 3.120E-13 0.OOOE+00 7.210E-14 0.000E+00 3.340E-14 BR-83 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 1.680E-02 0.000E+00 1.170E-02 BR-84 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 1.520E-29 0.000E+00 1.930E-24 BR-85 0.000E+00 0.000E+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 0.000E+00 0.000E+00 RB-86 0.000E+00 3.110E+08 0.OOOE+00 0.000E+00 0.OOOE+00 6.140E+07 0.OOOE+00 1.450E+08 RB-88 0.OOOE+00 2.570E-46 0.OOOE+00 0.OOOE+00 0.000E+00 3.550E-57 0.000E+00 1.360E-46 RB-89 0.OOOE+00 5.190E-54 0.OOOE+00 0.000E+00 0.000E+00 3.020E-67 0.000E+00 3.650E-54 SR-89 3.050E+09 0.000E+00 0.000E+00 0.OOOE+00 0.OOOE+00 4.890E+08 0.000E+00 8.750E+07 SR-90 9.830E+10 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00 2.840E+09 0.000E+00 2.410E+10 SR-91 6;070E+04 0.000E+00 0.OOOE+00 0.000E+00 0.OOOE+00 2.890E+05 0.OOOE+00 2.450E+03 Appendix G Ri Adult Goat Milk - Page 1 of 3 0

0 0

January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX G R, Adult Dose Factors for use in the Gaseous Dose Calculations Agegroup:

ADULT Pathway:

Grs/Goat/Milk (GMILK)

Units:

m2.mrem/yr / l+/-Ci/sec; mrem/yr/

Ci/m (l-3)

Nuclide Bone Liv'e r T

Thy;roid

Kidney, Luiing..

GillO

-Skin Total Body SR-92 1.030E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 2.030E+01 0.OOOE+00 4.440E-02 Y-90 8.500E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 9.010E+04 0.OOOE+00 2.280E-01 Y-91 1.030E+03 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.670E+05 0.OOOE+00 2.760E+01 Y-91M 7.170E-21 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.11OE-20 0.OOOE+00 2.780E-22 Y-92 6.690E-06 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.170E-01 0.OOOE+00 1.960E-07 Y-93 2.680E-02 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 8.500E+02 0.OOOE+00 7.400E-04 ZR-95 1.130E+02 3.630E+01 0.OOOE+00 5.700E+01 0.OOOE+00 1.150E+05 0.o60E+00 2.460E+01 ZR-97 5.200E-02 1.050E-02 0.OOOE+00 1.580E-02 0.OOOE+00 3.250E+03 0.OOOE+00 4.800E-03 NB-95 9.910E+03 5.510E+03 0.OOOE+00 5.450E+03 0.OOOE+00 3.340E+07 0.OOOE+00 2.960E+03 MO-99 0.OOOE+00 2.970E+06 0.OOOE+00 6.730E+06 0.OOOE+00 6.890E+06 0.OOOE+00 5.660E+05 TC-99M 3.980E-01 1.130E+00-0.OOOE+00 1.710E+01 5.520E-01 6.660E+02 0.000E+00 1.430E+01 TC-101 3.11 OE-61 4.490E-61 0.OOOE+00 8.080E-60 2.290E-61 1.350E-72 0.OOOE+00 4.400E-60 RU-103 1.220E+02 0.OOOE+00 0.OOOE+00 4.660E+02 0.OOOE+00 1.430E+04 0.OOOE+00 5.260E+01 RU-105 1.030E-04 0.OOOE+00 0.OOOE+00 1.330E-03 0.OOOE+00 6.290E-02 0.OOOE+00 4.060E-05 RU-106 2.450E+03 0.OOOE+00 0.OOOE+00 4.730E+03 0.OOOE+00 1.580E+05 0.OOOE+00 3.100E+02 AG-110M 6.990E+06 6.460E+06 0.OOOE+00 1.270E+07 0.OOOE+00 2.640E+09 0.OOOE+00 3.840E+06 TE-125M 1.950E+06 7.080E+05 5.880E+05 7.950E+06 0.OOOE+00 7.800E+06 0.OOOE+00.

2.620E+05 TE-127 7.830E+01 2.810E+01 5.800E+01 3.190E+02 0.OOOE+00 6.180E+03 0.OOOE+00 1.700E+01 TE-127M 5.490E+06 1.960E+06 1.400E+06 2.230E+07 0.OOOE+00 1.840E+07 0.OOOE+00 6.690E+05 TE-129 3.390E-11 1.270E-11 2.600E-11 1.430E-10 0.OOOE+00 2.560E-11 0.OOOE+00 8.260E-12 TE-129M 7.220E+06 2.690E+06 2.480E+06 3.020E+07 0.OOOE+00 3.640E+07 0.OOOE+00 1.140E+06 TE-131 4.320E-34 1.810E-34 3.550E-34 1.890E-33 0.OOOE+00 6.120E-35 0.OOOE+00 1.360E-34 TE-131M 4.330E+04 2.120E+04 3.360E+04 2.150E+05 0.OOOE+00 2.100E+06 0.OOOE+00 1.770E+04 TE-132 2.880E+05 1.860E+05 2.060E+05 1.800E+06 0.OOOE+00 8.820E+06 0.OOOE+00 1.750E+05 11-130 5.040E+05 1.490E+06 1.260E+08 2.320E+06 0.OOOE+00 1.280E+06 0.OOOE+00 5.870E+05 Appendix G Ri Adult Goat Milk - Page 2 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX G R, Adult Dose Factors for use in the Gaseous Dose Calculations Agegroup:

ADULT Pathway:

Grs/Goat/Milk (GMILK) units:*'

m 2 mrem/yr / IiCi/sec; 3

m rem /cr /

jCi/m (H--3)

Nuclide Bone Liver i Thyroid

'Kidney Lung Gilii 2

Skin Total Body 1-131 3.550E+08 5.080E+08 1.670E+11 8.710E+08 0.OOOE+00 1.340E+08 0.OOOE+00 2.910E+08 1-132 1.970E-01 5.270E-01 1.840E+01 8.400E-01 0.OOOE+00 9.900E-02 0.OOOE+00 1.840E-01 1-133 4.640E+06 8.080E+06 1.190E+09 1.410E+07 0.000E+00 7.260E+06 0.OOOE+00 2.460E+06 1-134 2.420E-12 6.570E-12 1.140E-10 1.050E-11 0.OOOE+00 5.730E-15 0.OOOE+00 2.350E-12 1-135 1.540E+04 4.030E+04 2.660E+06 6-470E+04 O.OOOE+00 4.560E+04 0.OOOE+00 1.490E+04 CS-134 1.700E+10 4.040E+/-10 O.OOOE+00 1.310E+10 4.340E+09 7.060E+08 0.OOOE+00 3.300E+10 CS-136 7.900E+08 3.120E+09

  • 0.OOOE+00 1.730E+09 2.380E+08 3.540E+08 0.OOOE+00

,2.240E+09 CS-137 2.210E+10 3.030E+10 0.OOOE+00 1.030E+10 3.420E+09 5.860E+08 0.OOOE+00 1.980E+10 CS-138 2.710E-23 5.360E-23 0.OOOE+00 3.940E-23 3.890E-24 2.290E-28 0.OOOE+00 2.650E-23 BA-139 5.300E-09 3.780E-12 0.OOOE+00 3.530E-12 2.140E-12 9.400E-09 O.OOOE+00 1.550E-10 BA-140 3.230E+06 4.050E+03 0.000E+00 1.380E+03 2.320E+03 6.640E+06 0.OOOE+00 2.1 10E+05 BA-141 4.910E-47 3.710E-50 0.OOOE+00 3.450E-50 2.11 E-50 2.310E-56 O.OOOE+00 1.660E-48 BA-142 3.170E-81 3.260E-84 0.OOOE+00 2.750E-84 1.850E-84 6.OOOE+00 0.OOOE+00 2.OOOE-82 LA-140 5.410E-01 2.730E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.OOOE+04 0.OOOE+00 7.210E-02 LA-142 2.230E-12 1.010E-12 0.OOOE+00 0.OOOE+00 0.OOOE+00 7.410E-09 0.OOOE+00 2.530E-13 CE-141 5.810E+02 3.930E+02 0.OOOE+00 1.830E+02 0.OOOE+00 1.500E+06 0.OOOE+00 4.460E+01 CE-143 4.990E+00 3.690E+03 0.OOOE+00 1.620E+00 0.OOOE+00 1.380E+05 0.OOOE+00 4.080E-01 CE-144 4.290E+04 1.790E+04 0..OOOE+00 1.060E+04 0.OOOE+00 1.450E+07 0.OOOE+00 2.300E+03 PR-143 1.890E+01 7.600E+00 0.OOOE+00 4.390E+00 0.OOOE+00 8.300E+04 0.OOOE+00 9.390E-01 PR-144 7.050E-55 2.930E-55 0.OOOE+00 1.650E-55 0.OOOE+00 1.0101E-61 0.OOOE+00 3.580E-56 ND-147 1.130E+01 1.310E+01 0.OOOE+00 7.630E+00 0.00OE+00 6.270E+04 O.OOOE+00 7.810E-01 W-187 7.820E+02 6.530E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.140E+05 0.OOOE+00 2.280E+02 NP-239 4.410E-01 4.330E-02 0.OOOE+00 1.350E-01 0.OOOE+00 8.890E+03 0.OOOE+00 2.390E-02 Appendix G Ri Adult Goat Milk - Page 3 of 3 0

0 S

January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX G Ri Adult Dose Factors for use in the Gaseous Dose Calculations 2

Agegroup: -

ADULT

,Pathwvay:

Grs/Cow/Meat (CMEAT)

Units:, -

m mrem/yr / ItCi/sec; mrem/yr /Ci/m3

(-3)

Nuclide Bone:

Liver Throid'

]Kidney Lung Gilli Skin Total Body,--,

H-3 0.OOOE+00 3.250E+02 3.250E+02 3.250E+02 3.250E+02 3.250E+02 0.OOOE+00 3.250E+02 C-14 2.410E+08 4.830E+07 4.830E+07 4.830E+07 4.830E+07 4.830E+07 0.000E+00 4.830E+07 NA-24 1.360E-03 1.360E-03 1.360E-03 1.360E-03

.1.360E-03 1.360E-03 0.OOOE+00 1.360E-03 P-32 4.660E+09 2.900E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.240E+08 0.OOOE+00 1.800E+08 CR-51 0.OOOE+00 0.OOOE+00 4.2 1OE+03 1.550E+03 9.350E+03 1.770E+06 0.OOOE+00 7.050E+03 MN-54 0.OOOE+00 9.180E+06 0.OOOE+00 2.730E+06 0.000E+00 2.810E+07 0.OOOE+00 1.750E+06 MN-5 6 0.OOOE+00 1.320E-53 0.OOOE+00 1.680E-53 0.OOOE+00 4.220E-52 0.000E+00 2.350E-54 FE-55 2.930E+08 2.030E+08 0.OOOE+00 0.OOOE+00 1.130E+08 1.160E+08 0.OOOE+00 4.720E+07 FE-59 2.660E+08 6.240E+08 0.000E+00 0.000E+00 1.740E+08 2.080E+09 0.000E+00 2.390E+08 CO-58 0.OOOE+00 1.820E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.690E+08 0.OOOE+00 4.090E+07 CO-60 0.000E+00 7.520E+07 0.OOOE+00 0.000E+00 0.OOOE+00 1.410E+09 0.OOOE+00 1.660E+08 NI-63 1.890E+10 1.31 OE+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.730E+08 0.000E+00 6.330E+08 NI-65 2.250E-52 2.920E-53 0.OOOE+00 0.000E+00 0.OOOE+00 7.400E-52 0.OOOE+00 1.330E-53 CU-64 0.000E+00 2.710E-07 0.OOOE+00 6.830E-07 0.OOOE+00 2.310E-05 0.OOOE+00 1.270E-07 ZN-65 3.560E+08 1.130E+09 0.OOOE+00 7.570E+08.

0.000E+00 7.130E+08 0.OOOE+00 5.120E+08 ZN-69 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 BR-83 0.OOOE+00 0.OOOE+00 0.000E+0O 0.OOOE+00 0.OOOE+00 8.650E-57 0.OOOE+00 6.OOOE-57 BR-84 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 BR-85 0.OOOE+00 0.000E+00 0;OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00

  • 0.OOOE+00 RB-86 0.OOOE+00 4.870E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 9.600E+07 0.OOOE+00 2.270E+08 RB-88 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 RB-89 0.000E+06 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00 0.OOOE+00 0.000E+00 SR-89 3.020E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.840E+07 0.OOOE+00

.8.660E+06 SR-90 1.240E+10 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.590E+08 0.000E+00 3.050E+09 SR-91 1.520E-10 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 7.240E-10 0.OOOE+00 6.140E-12 Appendix G Ri Adult Cow Meat - Page 1 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX G K Adult Dose Factors for use in the Gaseous Dose Calculations Agegroup:

ADULT -

Pathway:

Grs/Cow/Meat (CMEAT)

Units:

m 2.mrem/yr / ýLCi/sec; mremlyr/ jtCi/m3 (11-3) yNuclide Bone Liver

-Thyioid Kidney Lung Gilli Skin T6tal Body SR-92 1.180E-49 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.340E-48 0.OOOE+00 5.100E-51 Y-90 1.080E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.140E+06 0.OOOE+00 2.890E+00 Y-91 1.130E+06 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.230E+08 0.OOOE+00 3.030E+04 Y-91M 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 Y-92 1.520E-39 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.660E-35 0.OOOE+00 4.430E-41 Y-93 4.690E-12 0.OOOE+00 0.OOOE+00 0.OOOE+00.

0.OOOE+00 1.490E-07 0.OOOE+00 1.300E-13 ZR-95 1.870E+06 6.010E+05

-0.000E+00 9.420E+05 O.OOOE+00 1.900E+09 0.OOOE+00 4.070E+05 ZR-97 2.070E-05 4.170E-06 0.OOOE+00 6.300E-06 0.000E+00 1.290E+00 0.OOOE+00 1.910E-06 NB-95 2.300E+06 1.280E+06 0.OOOE+00 1.260E+06 0.OOOE+00 7.760E+09 0.600E+00 6.870E+05 MO-99 0.OOOE+00 1.000E+05 0.OOOE+00 2.260E+05 0.OOOE+00 2.320E+05 0.OOOE+00 1.900E+04 TC-99M 4.450E-21 1.260E-20 0.OOOE+00 1.910E-19 6.150E-21 7.430E-18 0.OOOE+00 1.600E-19 TC-101 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RU-103 1.050E+08 0.OOOE+00 0.OOOE+00 4.010E+08 0.OOOE+00 1.230E+10 0.OOOE+00 4.530E+07 RU-105 5.780E-28 0.OOOE+00 0.OOOE+00 7.460E-27 0.OOOE+00 3.530E-25 0.000E+00 2.280E-28 RU-106 2.800E+09 0.OOOE+00 0.OOOE+00 5.400E+09 0.OOOE+00 1.810E+1 I 0.OOOE+00 3.540E+08 AG-110M 6.680E+06 6.180E+06 0.OOOE+00 1.220E+07 0.OOOE+00 2.520E+09 0.OOOE+00 3.670E+06 TE-125M 3.590E+08 1.300E+08 1.080E+08 1.460E+09 0.OOOE+00 1.430E+09 0.OOOE+00 4.810E+07 TE-127 2.120E-10 7.610E-11 1.570E-10 8.640E-10 0.OOOE+00 1.670E-08 0.000E+00 4.590E-11 TE-127M

1. 120E+09 3.990E+08 2.850E+08 4.530E+09 0.OOOE+00 3.740E+09 0.OOOE+00 1.360E+08 TE-129 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 0.OOOE+00 TE-129M 1.130E+09 4.230E+08 3.900E+08 4.730E+09 0.OOOE+00 5.71 OE+09 O.OOOE+00 1.790E+08 TE-131 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 TE-131M 4.510E+02 2.210E+02 3.490E+02 2.230E+03 0.OOOE+00 2.190E+04 0.OOOE+00 1.840E+02 TE-132 1.420E+06 9.180E+05 1.010E+06 8.840E+06 0.OOOE+00 4.340E+07 0.000E+00 8.620E+05 1-130 2.11 OE-06 6.220E-06 5.270E-04 9.700E-06 0.OOOE+00 5.350E-06 0.OOOE+00 2.450E-06 Appendix G Ri Adult Cow Meat - Page 2 of 3

0 January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX G Ri Adult Dose Factors for use in the Gaseous Dose Calculations Agegroup:

ADULT

Pathway:

Grs/Cow/Meat (CMEAT)

Units:

m.mrem/yr / ýXCisec; tS::

m2.mrem/yr

/ iCi/M 3 (H-3)

Niiclide

~Bone S

LiverK Thyroid ~

KidneyW

~Lng 1<

ili

~

Skin Total ilody 1-131 1.070E+07 1.540E+07 5.030E+09 2.630E+07 0.OOOE+00 4.050E+06 0.000E+00 8.800E+06 1-132 6.970E-59 1.860E-58 6.530E-57 2.970E-58 0.OOOE+00 3.500E-59 0.000E+00 6.530E-59 1-133 3.650E-01 6.350E-01 9.340E+01 1.110E+00 0.OOOE+00 5.710E-01 0.000E+00 1.940E-01 1-134 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00 1-135 4.420E-17 1.160E-16 7.640E-15 1.860E-16 0.OOOE+00 1.310E-16 0.000E+00 4.270E-17 CS-134 6.580E+08 1.560E+09 0.OOOE+O 0 5.060E+08 1.680E+08 2.740E+07 0.000E+00 1.280E+09 CS-136 1.210E+07 4.760E+07 0.OOOE+00 2.650E+07 3.630E+06 5.410E+06 0.OOOE+00 3.420E+07 CS-137 8.720E+08 1.190E+09 0.OOOE+00 4.050E+08 1.350E+08 2.310E+07 0.OOOE+00 7.810E+08 CS-138 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 BA-139 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 BA-140 2.870E+07 3.610E+04 0.000E+00 1.230E+04 2.070E+04 5.920E+07 0.OOOE+00 1.880E+06 BA-141-0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 BA-142 0.OOOE+00 0.000E+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00.

LA-140 3.710E-02 1.870E 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.370E+03 0.OOOE+00 4.940E-03 LA-142 3.470E-92 1.580E-92 0.OOOE+00 0.OOOE+00 0.000E+00 1.150E-88 0.OOOE+00 3.940E-93 CE-141 1.400E-+04 9.500E+03 0.OOOE+00 4.410E+03 0.OOOE+00 3.630E+07 0.000E+00 1.080E+03 CE-143 2.010E-02 1.480E+01 0.OOOE+00 6.530E-03 0.OOOE+00 5.550E+02 0.OOOE+00 1.640E-03 CE-144 1.460E+06 6.090E+05 0.OOOE+00 3.610E+05 0.000E+00 4.930E+08 0.OOOE+00 7.830E+04 PR-143 2.100E+04 8.410E+03 0.000E+00 4.850E+03 O.OOOE+00 9.180E+07 0.OOOE+00 1.040E+03 PR-144 0.060E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 ND-147 7.070E+03 8.170E+03 0.000E+00 4.780E+03 0.OOOE+00 3.920E+07 0.OOOE+00 4.890E+02 W-187 2.070E-02 1.730E-02 0.OOOE+00 0.OOOE+00 0.000E+00 5.660E+00 0.OOOE+00 6.040E-03 NP-239 2.590E-01 L 2.550E-02 0.OOOE+00 7.950E-02 0.OOOE+00 5.230E+03 0.000E+00 1.400E-02 Appendix G Ri Adult Cow Meat - Page 3 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX G R1 Adult Dose Factors for use in the Gaseous Dose Calculations Agegroup:

ADULT Pathway:

Vegetation (VEG)

Units:

m 2.mrem/yr / LCi/sec; Ci/m3 nmrem/yr (H-3)

Bone______

Liver_____

______________Lq Gilli<

Skin Total Body H-3 0.OOOE+00 -

2.260E+03 2.260E+03 2.260E+03 2.260E+03 2.260E+03 0.OOOE+00 2.260E+03 C-14 2.280E+08-4.550E+07 4.550E+07 4.550E+07 4.550E+07 4.550E+07 0.OOOE+00 4.550E+07 NA-24 2.690E+05 2.690E+05 2.690E+05 2.690E+05 2.690E+05 2.690E+05 0.OOOE+00 2.690E+05 P-32 1.400E+09 8.730E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.580E+08 0.OOOE+00 5.430E+07 CR-51 0.OOOE+00 0.OOOE+00 2.780E+04 1.020E+04 6.160E+04 1.170E+07 0.OOOE+00 4.640E+04 MN-54 0.OOOE+00 3.130E+08 0.OOOE+00 9.3 1OE+07 0.OOOE+00 9.590E+08 0.OOOE+00 5.970E+07 MN-56 0.OOOE+00 1.580E+01 0.OOOE+00 2.OOOE+01 0.OOOE+00 5.040E+02 0.OOOE+00 2.800E+00 FE-55 2.100E+08 1.450E+08 0.OOOE+00 0.OOOE+00 8.080E+07 8.3 1OE+07 0.OOOE+00 3.380E+07 FE-59 1.260E+08 2.960E+08 0.000E+00 0.OOOE+00 8.280E+07 9.880E+08 0.OOOE+00 1.140E+08

.CO-58 0.OOOE+00 3.070E+07 0.OOOE+00 0.OOOE+00 0.OOOE+0.0 6.230E+08 0.OOOE+00 6.890E+07 CO-60 0.000E+00 1.670E+08 0.OOOE+00 0.000E+00 0.OOOE+00 3.140E+09 0.OOOE+00 3.690E+08 NI-63 1.040E+10-7.210E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.500E+08 0.OOOE+00 3.490E+08 NI-65 6.150E+01 7.990E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.030E+02 0.000E+00 3.640E+00 CU-64 0.OOOE+00 9.200E+03 0.OOOE+00 2.320E+04 0.OOOE+00 7.840E+05 0.OOOE+00 4.320E+03 ZN-65 3.170E+08 1.010E+09 0.OOOE+00 6.750E+08 0.000E+00 6.360E+08 0.000E+00 4.560E+08 ZN-69 5.490E-06 1.050E-05 0.OOOE+00 6.830E-06 0.OOOE+00 1.580E-06 0.000E+00 7.310E-07 BR-83 O.OOOE+0O 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.470E+00 0.OOOE+00 3.110E+00 BR-84 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.940E-16 0.OOOE+00 2.480E-11 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RB-86 O.OOOE+00 2.190E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.330E+07 0.OOOE+00 1.020E+08 RB-88 0.OOOE+00 3.430E-22 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.740E-33 0.OOOE+00 1.820E-22 RB-89 0.OOOE+00 3.890E-26 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.260E-39 0.OOOE+00 2.730E-26 SR-89 9.970E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.600E+09 0.OOOE+00 2.860E+08 SR-90 6.050E+11 0.000E+00 0.000E+00 0.000E+00 0.OOOE+00 1.750E+10 0.000E+00 1.480E+1 1 SR 3.050E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.450E+06 0.OOOE+00 1.230E+04 Appendix G Ri Adult Vegetation - Page 1 of 3 0÷

0 January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX G Ri Adult Dose Factors for use in the Gaseous Dose Calculations Agegroup:

ADULT

!Pathway:

Vegetation (VEG)

Units:

nm 2 mrem/yr / ltCi/sec;

_:__",__mrem/

y r/

m (H-3)

'-Nuclide

'B,)one Liver-

Thyroid, Kidiiey,
Lun

,Gilli 4i.. i.

K TtlBody SR-92 4.270E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 8.450E+03 0.OOOE+00 1.850E+01 Y-90 1.330E+04 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.410E+08 0.OOOE+00 3.570E+02 Y-91 5.1101E+06 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 2.8 1OE+09 0.000E+00 1.370E+05 Y-91M 5.220E-09 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 1.530E-08 0.OOOE+00 2.020E-10 Y-92 9.150E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.600E+04 0.OOOE+00 2.680E-02 Y-93 1.700E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 5.380E+06 0.OOOE+00 4.680E+00 ZR-95 1.170E+06 3.770E+05 0.OOOE+00 5.910E+05 0.OOOE+00 1.190E+09 0.OOOE+00 2.550E+05 ZR-97 3.370E+02 6.810E+01 0.OOOE+00 1.030E+02 0.OOOE+00 2.11OE+07 0.OOOE+00 3.11OE+01 NB-95 1.420E+05 7.920E+04 0.OOOE+00 7.830E+04 0.OOOE+00 4.810E+08 0.OOOE+00 4.260E+04 MO-99 0.OOOE+00 6.150E+06 O.OOOE+00 1.390E+07 0.000E+00 1.430E+07 0.OOOE+00 1.170E+06 ITC-99M 3.100E+00 8.770E+06 0.OOOE+00 1.330E+02 4.300E+00 5.190E+03 0.OOOE+00 1.120E+02 TC-101 8.220E-31 1.180E-30 0.OOOE+00 2.130E-29 6.050E-31 3.560E-42 0.000E+00 1.160E-29 RU-103 4.770E+06 0.OOOE+00 0.OOOE+00 1.820E+07 0.OOOE+00 5.570E+08 0.OOOE+00 2.060E+06 RU-105 5.390E+01 0.OOOE+00 0.OOOE+00 6.960E+02 0.000E+00 3.290E+04 0.OOOE+00 2.130E+01 RU-106 1.930E+08 0.OOOE+00 0.OOOE+00 3.720Et08 0.OOOE+00 1.250E+10 0.OOOE+00 2.440E+07 AG-110M 1.050E+07 9.750E+06 0.OOOE+00 1.920E+07 0.OOOE+00 3.980E+09 0.OOOE+00 5.790E+06 TE-125M 9.660E+07 3.500E+07 2.900E+07 3.930E+08 0.OOOE+00 3.860E+08 0.OOOE+00 1.290E+07 TE-127 5.660E+03 2.030E+03 4.190E+03 2.310E+04 0.OOOE+00 4.470E+05 0.OOOE+00 1.220E+03 TE-127M 3.490E+08 1.250E+08 8.920E+07 1.420E+09 0.OOOE+00

1. 170E+09 0.OOOE+00 4.260E+07 TE-129 7.630E-04 2.870E-04 5.850E-04 3.210E-03 0.OOOE+00 5.760E-04 0.OOOE+00 1.860E-04 TE-129M 2.510E+08 9.380E+07 8.630E+07 1.050E+09 0.OOOE+00 1.270E+09 0.OOOE+00 3.980E+07 TE-131 1.500E-15 6.270E-16 1.230E-15 6.570E-15 0.OOOE+00 2.130E-16 0.OOOE+00 4.740E-16 TE-131M 9.120E+05 4.460E+05 7.060E+05 4.5201+06 0.OOOE+00 4.430E+07 0.OOOE+00 3.720E+05 TE-132.

4.300E+06 2.780E+06 3.070E+06 2.680E+07 0.OOOE+00 1.320E+08 0.OOOE+00 2.610E+06 1-130 3.920E+05 1.160E+06 9.810E+07 1.810E+06 0.OOOE+00 9.960E+05 0.OOOE+00 4.570E+05 I

Appendix G Ri Adult Vegetation - Page 2 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX G R1 Adult Dose Factors for use in the Gaseous Dose Calculations Agegroup:

ADULT Pathway:

Vegetation (VEG)

Units:

m 2.mrem/yr / pCi/sec; mrem/yr/

i/m 3 (-3)

Nuclide B6ne,:-:

Liver.

Thyroid Ki dne*

'Lung Gilai Skin Total Body 1-131 8.080E+07 1.160E+08 3.790E+1 0 1.980E+08 0.000E+00 3.050E+07 0.OOOE+00 6.620E+07 1-132 5.760E+01 1.540E+02 5.390E+03 2.450E+02 0.000E+00 2.890E+01 0.000E+00 5.390E+01 1-133 2.090E+06 3.630E+06 5.330E+08 6.330E+06 0.000E+00 3.260E+06 0.OOOE+00 1.11OE+06 1-134 9.650E-05 2.620E-04 4.540E-03 4.170E-04 0.000E+00 2.290E-07 0.OOOE+00 9.380E-05 1-135 3.900E-04 1.020E+05 6.730E+06 1.640E+05 O.000E+00 1.150E+05 0.OOOE+00 3.770E+04 CS-134 4.670E+09 1.110E+10 0.OOOE+00, 3.590E+09 1.190E+09 1-.940E+08 0.000E+00 9.080E+09 CS-136 4.270E+07 1.680E+08 0.OOOE+00 9.380E+07 1.290E+07 1.910E+07 0.000E+00 1.210E+08 CS-137 6.360E+09 8.700E+09 0.000E+00 2.950E+09 9.810E+08 1.680E+08 0.000E+00 5.700E+09 CS-138 3.920E-11 7.730E-11 0.000E+00 5.680E-11 5.610E-12 3.300E-16 0.000E+00 3.830E-11 BA-139 2.860E-02 2.030E-05 0.000E+00 1.900E-05 1.150E-05 5.060E-02 0.OOOE+00 8.360E-04 BA-140 1.280E+08 1.610E+05 0.OOOE+00 5.490E+04 9.240E+04.

2.650E+08 0.OOOE+00 8.420E+06 BA-141 1.150E-21 8.700E-25 0.OOOE+00 8.090E-25 4.940E-25 5.430E-31 0.000E+00 3.890E-23 BA-142 5.960E-39 6.120E-42 0.000E+00 5.170E-42 3.470E-42 8.390E-57 0.OOOE+00 3.750E-40 LA-140 1.980E+03 9.970E+02 0.OOOE+00 0.OOOE+00 0.000E+00 7.320E+07 0.000E+00 2.630E+02 LA-142 2.020E-04 9.190E-05 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.710E-01 0.000E+00 2.290E-05 CE-141 1.970E+05 1.330E+05 0.OOOE+00 6.190E+04 0.000E+00 5.100E+08 0.000E+00 1.510E+04 CE-143 9.980E+02 7.380E+05 0.OOOE+00 3.250E+02 0.OOOE+00 2.760E+07 0.000E+00 8.160E+01 CE-144 3.290E+07 1.380E+07 0.OOOE+00 8.160E+06 0.OOOE+00 1.110E+10 O.000E+00 1.770E+06 PR-143 6.260E+04 2.510E+04 0.000E+00 1.450E+04 0.OOOE+00 2.740E+08 0.000E+00 3.100E+03 PR-144 3.090E-26 1.280E-26 0.OOOE+00 7.230E-27 0.OOOE+00 4.440E-33 0.000E+00 1.570E-27 ND-147 3.330E+04 3.850E+04 0.000E+00 2.250E+04 0.OOOE+00 1.850E+08 0.000E+00 2.310E+03 W-187 3.800E+04 3.180E+04 0.OOOE+00 0.000E+00 0.OOOE+00 1.040E+07 0.000E+00 1.11OE+04 NP-239 1.430E+03 1.400E+02 0.000E+00 4.380E+02 0.OOOE+00 2.880E+07 0.OOOE+00 7.740E+01 Appendix G Ri Adult Vegetation - Page 3 of 3

j 0

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

,0 0

January, 2010 Revision 52 APPENDIX G Ri Adult Dose Factors for use in the Gaseous Dose Calculations Agegroup:

ADULT Pathway:

Inhalation (INHL)

Units:

mrem/yr / ýtCi/m 3 Kidk L"...

Total Body, Nuclide.

Bone-

Liver, Thyroid gKidney Lun Gilli 7Ski i<

Tota Bod H-3 0.OOOE+00 1.260E+03 1.260E+03 1.260E+03 1.260E+03 1.260E+03 0.000E+00 1.260E+03 C-14 1.820E+04 3.410E+03 3.410E+03 3.410E+03 3.410E+03 3.410E+03 0.OOOE+00 3.410E+03 NA-24 1.020E+04 1.020E+04 1.020E+04 1.020E+04 1.020E+04 1.020E+04 O.000E+00 1.020E+04 P-32 1.320E+06 7.710E+04 0.OOOE+00 0.OOOE+00 0.OOOE+00 8.640E+04 0.OOOE+00 5.010E+04 CR-51 0.OOOE+00 0.OOOE+00 5.950E+01 2.280E+01 1.440E+04 3.320E+03 0.OOOE+00 1.000E+02 MN-54 0.0O0E+00 3.960E+04 0.000E+00 9.840E+03 1.400E+06 7.740E+04 0.000E+00 6.300E+03 MN-56 0.OOOE+00 1.240E+00 0.OOOE+00 1.300E+00 9.440E+03 2.020E+04 0.OOOE+00 1.830E-01 FE-55 2.460E+04 1.700E+04 0.OOOE+00 0.OOOE+00 7.210E+04 6.030E+03 0.OOOE+00 3.940E+03 FE-59 1.180E+04 2.780E+04 0.000E+00 0.OOOE+00 1.020E+06 1.880E+05 0.OOOE+00 1.060E+04 CO-58 0.006E+00 -

1.580E+03 0.OOOE+00 0.OOOE+00 9.280E+05 1.060E+05 0.OOOE+00 2.070E+03 CO-60 0.OOOE+00 1.150E+04 0.OOOE+00 0.OOOE+00 5.970E+06 2.850E+05 0;000E+00 1.480E+04 NI-63 4.320E+05 3.140E+04 0.OOOE+00 0.OOOE+00 1.780E+05 1.340E+04 0.000E+00 1.450E+04 NI-65 1.540E+00 2.100E-01 0.OOOE+00 0.OOOE+00 5.600E+03 1.230E+04 0.OOOE+00 9.120E-02 CU-64 0.OOOE+00 1.460E+00 0.OOOE+00 4.620E+00 6.780E+03 4.900E+04 0.OOOE+00 6.150E-01 ZN-65 3.240E+04 1.030E+05 0.000E+00 6.900E+04 8.640E+05 5.340E+04 0.000E+00 4.660E+04 ZN-69 3.380E-02 6.510E-02 6.0003E+00 4.220E-02 9.200E+02 1'.630E+01 0.OOOE+00 4.520E-03 BR-83 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.OOOE+00 2.320E+02 0.OOOE+00 2.410E+02 BR-84 0.OOOEt00 0.000E+00 0.OOOE+00 0.000E+00 0.OOOE+00 1.640E-03 0.00OE+00 3.130E+02 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00

. 0.OOOE+00 1.280E+01 RB-86 0.OOOE+00 1.350E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.660E+04 0.OOOE+00 5.900E+04 RB-88 0.OOOE+00 3.870E+02 0.000E+00 0.OOOE+00 0.OOOE+00 3.340E-09 0.OOOE+00 1.930E+02 RB-89 0.OOOE+00 2.560E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 9.280E-12 0.OOOE+00 1.700E+02 SR-89 3.040E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.400E+06 3.500E+05 0.000E+00 8.720E+03 SR-90 9.920E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 9.600E+06 7.220E+05 0.OOOE+00 6.100E+06 SR-91 6.190E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.650E+04 1.910E+05 0.OOOE+00 2.500E+00 Appendix G Ri Adult Inhal ation - Page 1 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX G R. Adult Dose Factors for use in the Gaseous Dose Calculations Agegroup:

ADULT Pathway:

Inhalation (INHL)

. Units:.

mrem/yr / ýCi/m 3 Nuclide Bone Liver Thyroid Kidhey Lung.ý Giili Sin-Total Bo dy SR-92 6.740E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.650E+04 4.300E+04 0.OOOE+00 2.910E-01 Y-90 2.090E+03 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.700E+05 5.060E+05 0.OOOE+00 5.610E+01 Y-91 4.620E+05 0.OOOE+00 0.OOOE+00 0.000E+00 1.700E+06 3.850E+05 0.OOOE+00 1.240E+04 Y-91M 2.610E-01 0.000E+00 0.OOOE+00 0.OOOE+00 1.920E+03 1.330E+00 0.OOOE+00 1.020E-02 Y-92 1.030E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.570E+04 7.350E+04 0.OOOE+00 3.020E-01 Y-93 9.440E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.850E+04 4.220E+05 0.OOOE+00 2.610E+00 ZR-95 1.070E+05 3.440E+04 0.OOOE+00 5.420E+04 1.770E+06 1.500E+05 0.OOOE+00 2.330E+04 ZR-97 9.680E+01 1.960E+01 0.OOOE+00 2.970E+01 7.870E+04 5.230E+05 0.OOOE+00 9.040E+00 NB-95 1.410E+04 7.820E+03 0.OOOE+00 7.740E+03 5.050E+05 1.040E+05

(:OOOE+00 4.210E+03 MO-99 0.OOE+00 1.210E+02 0.OOOE+00 2.910E+02 9.120E+04 2.480E+05 0.OOOE+00 2.300E+01 TC-99M 1.030E-03 2.910E-03 0.OOOE+00 4.420E-02 7.640E+02 4.160E+03 0.000E+00 3.700E-02 TC-101 4.180E-05 6.020E-05 0.OOOE+00 1.080E-03 3.990E+02 1.090E-11 0.OOOE+00 5.900E-04 RU-103 1.530E+03 0.OOOE+00 0.OOOE+00 5.830E+03 5.050E+05 1.100E+05 0.OOOE+00 6.580E+02 RU-105 7.900E-0 1 0.OOOE+00 0.OOOE+00 1.020E+00 1.1 OOE+04 4.820E+04 0.OOOE+00 3.110E-01 RU-106 6.910E+04 0.OOOE+00 0.OOOE+00 1.340E+05 9.360E+06 9.120E+05 0.OOOE+00 8.720E+03 AG-110M 1.080E+04 1.000E+04 0.OOOE+00 1.970E+04 4.630E+06 3.020E+05 0.OOOE+00 5.940E+03 TE-125M 3.420E+03 1.580E+03 1.050E+03 1.240E+04 3.140E+05 7.060E+04 0.OOOE+00 4.670E+02 TE-127 1.400E+00 6.420E-01 1.060E+00 5.100E+00 6.510E+03 5.740E+04 0.OOOE+00 3.100E-01 TE-127M 1.260E+04 5.770E+03 3.290E+03 4.580E+04 9.600E+05 1.500E+05-0.OOOE+00 1.570E+03 TE-129 4.980E-02 2.390E-02 3.900E-02 1.870E-01 1.940E+03 1.570E+02 0.OOOE+00 1.240E-02 TE-129M 9.760E+03 4.670E+03 3.440E+03 3.660E+04 1.160E+06 3.830E+05 0.OOOE+00 1.580E+03 TE-131 1.11OE-02 5.950E-03 9.360E-03 4.370E-02 1.390E+03 1.840E+01 0.OOOE+00 3.590E-03 TE-131M 6.990E+01 4.360E+01 5.500E+01 3.090E+02 1.460E+05 5.560E+05 0.OOOE+00 2.900E+01 TE-132 2.600E+02 2.150E+02 1.900E+02 1.460E+03 2.880E+05 5.100E+05 0.OOOE+00 1.620E+02 1-130 4.580E+03 1.340E+04 1.140E+06 2.090E+04 0.OOOE+00 7.690E+03 0.OOOE+00 5.280E+03 Appendix G Ri Adult Inhalation - Page 2 of 3

January, 2(

Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX G Ri Adult Dose Factors for use in the Gaseous Dose Calculations Agegroup:

ADULT Pathway:

Inhalation (INHL) units:

mrem/yr / l+/-Ci/m 3 Nuclide

Bone,
  • Liero Thyroid Kidneys Lung lGillii
sii, TotaltBody 3 1-131 2.520E+04 3.580E+04 1.190E+07 6.130E+04 O.OOOE+00 6.280E+03 O.OOOE+00 2.050E+04 1-132 1.160E+03 3.260E+03 1.140E+05 5.180E+03 O.OOOE+00 4.060E+02 O.OOOE+00 "

1.160E+03 1-133 8.640E+03 1.480E+04 2.150E+06 2.580E+04 O.OOOE+00 8.880E+03 O.OOOE+00 4.520E+03 1-134 6.440E+02 1.730E+03 2.980E+04 2.750E+03 O.OOOE+00 1.010E+00 O.OOOE+00 6.150E+02 1-135 2.680E+03 6.980E+03 4.480E+05 1.11 OE+04 O.OOOE+00 5.250E+03 O.OOOE+00 2.570E+03 CS-134 3.730E+05 8.480E+05 O.OOOE+00 2.870E+05 9.760E+04 1.040E+04 O.OOOE+00 7.280E+05 CS-136 3.900E+04 1.460E+05 0.000E+00 8.560E+04 1.200E+04 1.170E+04 O.OOOE+00 1.100E+05 CS-137 4.780E+05 6.210E+05 O.OOOE+00 2.220E+05 7.520E+04 8.400E+03 0.000E+00 4.280E+05 CS-138 3.310E+02 6.210E+02 O.OOOE+00 4.800E+02 4.860E+01 1.860E-03 O.OOOE+00 3.240E+02 BA-139 9.360E-01 6.660E-04

  • O.OOOE+00 6.220E-04 3.760E+03 8.960E+02 O.OOOE+00 2.740E-02 BA-140 3.900E+04 4.900E+O1 O.OOOE+00 1.670E+01 1.270E+06 2.180E+05 O.OOOE+00 2.570E+03 BA-141 1.OOOE-01 7.530E-05 O.OOOE+00 7.OOOE-05 1.940E+03 1.160E-07 O.OOOE+00 3.360E-03 BA-142 2.630E-02 2.700E-05 O.OOOE+00 2.290E-05 1.190E+03 1.570E-16 O.OOOE+00 1.660E LA-140 3.440E+02 1.740E+02 O.OOOE+00 O.OOOE+00 1.360E+05 4.580E+05 O.OOOE+00 4.580E+01 LA-142 6.830E-01 3.100E-01 O.OOOE+00 O.OOOE+00 6.330E+03 2.110E+03 O.OOOE+00 7.720E-02 CE-141 1.990E+04 1.350E+04 O.OOOE+00 6.260E+03 3.620E+05 1.200E+05 O.OOOE+0"0 1.530E+03 CE-143 1.860E+02 1.380E+02 O.OOOE+00 6.080E+01 7.980E+04 2.260E+05 O.OOOE+00 1.530E+01 CE-144 3.430E+06 1.430E+06 O.OOOE+00 8.480E+05 7.780E+06 8.160E+05 O.OOOE+00 1.840E+05 PR-143 9.360E+03 3.750E+03 O.OOOE+00 2.160E+03 2.810E+05 2.000E+05 O.OOOE+00 4.640E+02 PR-144 3.010E-02 1.250E-02 O.OOOE+00 7.050E-03 1.020E+03 2.150E-08 O.OOOE+00 1.530E-03 ND-147 5.270E+03 6.100E+03 O.OOOE+00 3.560E+03 2.210E+05 1.730E+05 O.OOOE+00 3.650E+02 W-187 8

8.480E+00 7.080E+00 O.OOOE+00 O.OOOE+00 2.900E+04 1.550E+05 O.OOOE+00 2.480E+00 NP-239 2.300E+02 2.260E+01 O.OOOE+00 7.OOOE+01 3.760E+04 1.190E+05 O.OOOE+00 1.240E+01 Appendix G Ri Adult Inhalation - Page 3 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX G Ri Adult Dose Factors for use in the Gaseous Dose Calculations Agegroup:,

ADULT Pathway:

Ground Plane Deposition (GPD)

Units:

m2.mrem/yr / jiCi/sec Nuclide

'.Boine LiVer Thyroid.'

A'.Kidney:

Lun-,Giili Skin-,,

Total Body" H-3 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 C-14 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 NA-24 1.190E+07 1.190E+07 1.190E+07 1.190E+07 1.190E+07 1.190E+07 1.390E+07 1.190E+07 P-32 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 CR-51 4.660E+06 4.660E+06 4.660E+06 4.660E+06 4.660E+06 4.660E+06 5.510E+06 4.660E+06 MN-54 1.390E+09 1.390E+09 1.390E+09 1.390E+09 1.390E+09 1.390E+09 1.630E+09 1.390E+09 MN-56 9.020E+05 9.020E+05 9.020E+05 9.020E+05 9.020E+05 9.020E+05 1.070E+06 9.020E+05 FE-55 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.00OE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 FE-59 2.730E+08 2.730E+08 2.730E+08 2.730E+08 2.730E+08 2.730E+08 3.210E+08 2.730E+08 CO-58 3.790E+08 3.790E+08 3.790E+08 3.790E+08 3.790E+08 3.790E+08 4.440E+08 3.790E+08 CO-60 2.150E+10 2.150E+10 2.150E+10 2.150E+10 2.150E+10 2.150E+10 2.530E+10 2.150E+10 NI-63 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOQE+00 0.OOOE+00 0.OOOE+00 NI-65 2.970E+05 2.970E+05 2.970E+05 2.970E+05 2.970E+05 2.970E+05 3.450E+05 2.970E+05 CU-64 6.070E+05 6.070E+05 6.070E+05 6.070E+05 6.070E+05 6.070E+05 6.880E+05 6.070E+05 ZN-65 7.470E+08 7.470E+08 7.470E+08 7.470E+08 7.470E+08 7.470E+08 8.590E+08 7.470E+08 ZN-69 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 BR-83 4.870E+03 4.870E+03 4.870E+03 4.870E+03 4.870E+03 4.870E+03 7.080E+03 4.870E+03 BR-84 2.030E+05 2.030E+05 2.030E+05 2.030E+05 2.030E+05 2.030E+05 2.360E+05 2.030E+05 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RB-86 8.990E+06 8.990E+06 8.990E+06 8.990E+06 8.990E+06 8.990E+06 1.030E+07 8.990E+06 RB-88 3.310E+04 3.310E+04 3.310E+04 3.310E+04 3.310E+04 3.310E+04 3.780E+04 3.310E+04 RB-89 1.230E+05 1.230E+05 1.230E+05 1.230E+05 1.230E+05 1.230E+05 1.480E+05 1.230E+05 SR-89 2.160E+04 2.160E+04 2.160E+04 2.160E+04 2.160E+04 2.160E+04 2.510E+04 2.160E+04 SR-90 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 SR-91 2.150E+06 2.150E+06 2.150E+/-06 2.150E+06 2.150E+06 2.150E+06 2.510E+06 2.150E+06 Appendix G Ri Adult Ground Plane Deposition - Page 1 of 3 0

0 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

O January, 2010 Revision 52 APPENDIX G Ri Adult Dose Factors for use in the Gaseous Dose Calculations Agegroup:

ADULT Pathway:

Ground Plane Deposition (GPD)

Units:

m2*mrem/yr / *tCi/sec Nuclide Bone

.Liver'

,'Thyroid

-Kidney Lung Gilli Skin

-Total Body.

SR-92 7.770E+05 7.770E+05 7.770E+05 7.770E+05 7.770E+05 7.770E+05 8.630E+05 7.770E+05 Y-90 4.490E+03 4.490E+03 4.490E+03 4.490E+03 4.490E+03 4.490E+03 5.3 1OE+03 4.490E+03 Y-91 1.070E+06 1.070E+06 1.070E+06 1.070E+06 1.070E+06 1.070E+06 1.210E+06 1.070E+06 Y-91M 1.000E+05 1.000E+05 1.000E+05 1.000E+05 1.000E+05 1.000E+05 1.160E+05 1.000E+05 Y-92 1.800E+05 1.800E+05 1.800E+05 1.800E+05 1.800E+05 1.800E+05 2.140E+05 1.800E+05 Y-93 1.830E+05 1.830E+05 1.830E+05 1.830E+05 1.830E+05 1.830E+05 2.510E+05 1.830E+05 ZR-95 2.450E+08 2.450E+08 2.450E+08 2.450E+08 2.450E+08 2.450E+08 2.840E+08 2.450E+/--08 ZR-97 2.960E+06 2.960E+06 2.960E+06 2.960E+06 2.960E+06 2.960E+06 3.440E+06 2.960E+06 NB-95 1.370E+08 1.370E+08 1.370E+08 1.370E+08 1.370E+08 1.370E+08 1.610E+08 1.370E+08 MO-99 3.990E+06 3.990E+06 3.990E+06 3.990E+06 3.990E+06 3.990E+06

,4.630E+06 3.990E+06 TC-99M 1.840E+05 1.840E+05 1.840E+05 1.840E+05 1.840E+05 1.840E+05 2.11OE+05 1.840E+05 TC-101 2.040E+04 2.040E+04 2.040E+04 2.040E+04 2.040E+04 2.040E+04 2.260E+04 2.040E+04 RU-103 1.080E+08 1.080E+08 1.080E+08 1.080E+08 1.080E+08 1.080E+08 1.260E+08 1.080E+08' RU-105 6.360E+05 6.360E+05 6.360E+05 6.360E+05 6.360E+05 6.360E+05 7.210E+05 6.360E+05 -

RU-106 4.220E+08 4.220E+08 4.220E+08 4.220E+08 4.220E+08 4.220E+08 5.070E+08 4.220E+08 AG-11OM 3.440E+09 3.440E+09 3.440E+09 3.440E+09 3.440E+09 3.440E+09 4.010E+09 3.440E+09 TE-125M 1.550E+06 1.550E+06 1.550E+06 1.550E+06 1.550E+06 1.550E+06 2.130E+06 1.550E+06 TE-127 2.980E+03 2.980E+03 2.980E+03 2.980E+03 2.980E+03 2.980E+03 3.280E+03 2.980E+03 TE-127M 9.160E+04 9.160E+04 9.160E+04 9.160E+04 9.160E+04 9.160E+04 1.080E+05 9.160E+04 TE-129 2.620E+04 2.620E+04 2.620E+04 2.620E+04 2.620E+04 2.620E+04 3.100E+04 2.620E+04 TE-129M 1.980E+07 1.980E+07 1.980E+07 1.980E+07 1.980E+07 1.980E+07 2.310E+07 1.980E+07 TE-131 2.920E+04 2.920E+04 2.920E+04 2.920E+04 2.920E+04 2.920E+04 3.450E+07 2.920E+04 TE-131M 8.030E+06 8.030E+06 8.030E+06 8.030E+06 8.030E+06 8.030E+06 9.460E+06 8.030E+06 TE-132 4.230E+06 4.230E+06 4.230E+06 4.230E+06 4.230E+06 4.230E+06 4.980E+06 4.230E+06 11-130 5.'510E+06 5;510E+06 5.510E+06 5.510E+06 5.510E+06 5.510E+06 6.690E+06 5.510E+06 Appendix G Ri Adult Ground Plane Deposition - Page 2 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX G Ri Adult Dose Factors for use in the Gaseous Dose Calculations Agegroup:

ADULT Pathw'ay:

Ground Plane Deposition (GPD)

Units:

m 2.mrem/yr / XtCi/sec Nuclide Bone

`Liver Thyroid

- Kidney.

Lung"

-Gilli' Skin Total Body 1-131 1.720E+07 1.720E+07 1.720E+07 1.720E+07 1.720E+07 1.720E+07 2.090E+07 1.720E+07 1-132 1.250E+06 1.250E+06 1.250E+06 1.250E+06 1.250E+06 1.250E+06 1.470E+06 1,250E+06 1-133 2.450E+06 2.450E+06 2.450E+06 2.450E+06 2.450E+06 2.450E+06 2.980E+06 2.450E+06 1-134 4.470E+05 4.470E+05 4.470E+05 4.470E+05 4.470E+05 4.470E+05 5.300E+05 4.470E+05 1-135 2.530E+06 2.530E+06 2.530E+06 2.530E+06 2.530E+06 2.530E+06 2.950E+06 2.530E+06 CS-134 6.860E+09 6.860E+09 6.860E+09 6.860E+09 6.860E+09 6.860E+09 8.OOOE+09 6.860E+09 CS-136 1.510E+08 1.510E+08 1.510E+08 1.510E+08 1.510E+08 1.510E+08 1.710E+08 1.510E+08 CS-137 1.030E+10 1.030E+10 1.030E+10 1.030E+10, 1.030E+10 1.030E+10 1.200E+10 1.030E+10 CS-138 3.590E+05 3.590E+05 3.590E+05 3.590E+05 3.590E+05 3.590E+05 4.100E+05 3.590E+05 BA-139 1.060E+05 1.060E+05 1.060E+05 1.060E+05 1.060E+05 1.060E+05 1.190E+05 1.060E+05 BA-140 2.050E+07 2.050E+07 2.050E+07 2.050E+07 2.050E+07 2.050E+07 2.350E+07 2.050E+07 BA-141 4.170E+04 4.170E+04 4.170E+04 4.170E+04 4.170E+04 4.170E+04 4.750E+04 4.170E+04 BA-142 4.490E+04 4.490E+04 4.490E+04 4.490E+04 4.490E+04 4.490E+04 5.11OE+04 4.490E+04 LA-140 1.920E+07 1.920E+07 1.920E+07 1.920E+07 1.920E+07 1.920E+07 2.180E+07 1.920E+07 LA-142 7.600E+05 7.600E+05 7.600E+05 7.600E+05 7.600E+05 7.600E+05 9.120E+05 7.600E+05 CE-141 1.370E+07 1.370E+07 1.370E+07 1.370E+07 1.370E+07 1.370E+07 1.540E+07 1.370E+07 CE-143 2.310E+06 2.310E+06 2.310E+06 2.310E+06 2.310E+06 2.310E+06 2.630E+06 2.310E+06 CE-144 6.950E+07 6.950E+07 6.950E+07 6.950E+07 6.950E+07 6.950E+07 8.040E+07 6.950E+07 PR-143 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 PR-144 1.830E+03 1.830E+03 1.830E+03 1.830E+/-03 1.830E+03 1.830E+03 2.11OE+03 1.830E+03 ND-147 8.390E+06 8.390E+06 8.390E+06 8.390E+06 8.390E+06 8.390E+06 1.010E+07 8.390E+06 W-187 2.350E+06 2.350E+06 2.350E+06 2.350E+06 2.350E+06 2.350E+06 2.730E+06 2.350E+06 NP-239 1.710E+06 1.710E+06 1.710E+06 1.710E+06 1.710E+06 1.710E+06 1.980E+06 1.710E+06 Appendix G Ri Adult Ground Plane Deposition - Page 3 of 3

0 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

R. Teen Dose January, 2010 Revision 52 APPENDIX H Factors for use in the Gaseous Dose Calculations Agegr'up:

TEEN Pathway:

Grs/Cow/Milk (CMILK)

'Units:

In 2.mrem/yr / pCi/sec;

  • '*mrem/'r

/ tCi/m3 (1--3)

Nuclide Bone Liver -

Thyroid

Kidney, Lug.

'"Gilli 7

  • Skin Total Bod*y H-3 0.OOOE+00 9.940E+02' 9.940E+02 9.940E+02 9.940E+02 9.940E+02 0.OOOE+00 9.940E+02 C-14 4.860E+08 9.720E+07 9.720E+07 9.720E+07 9.720E+07 9.720E+07 0.OOOE+00 9.720E+07 NA-24 4.260E+06 4.260E+06 4.260E+06 4.260E+06 4.260E+06 4.260E+06 0.OOOE+00 4.260E+06 P-32 3.150E+10 1.950E+09 0.OOOE+00 0.OOOE+00 0.000E+60.

2.650E+09 0.OOOE+00 1.220E+09 CR-51 0.OOOE+00 0.OOOE+00 2.770E+04 1.090E+04 7.130E+04 8.390E+06 0.OOOE+00 4.990E+04 MN-54 0.OOOE+00 1.400E+07 0.OOOE+00 4.180E+06 0.000E+00 2.870E+07 0.OOOE+00 2.780E+06 MN-56 9.6003E+00 7.250E-03 0.OOOE+00 9.180E-03 0.OOOE+00 4.770E-01 0.OOOE+00 1.290E-03 FE-55 4.450E+07 3.160E+07 0.OOOE+00 0.OOOE+00 2.OOOE+07 1.370E+07 0.OOOE+00 7.360E+06 FE-59 5.180E+07 1.210E+08 0.OOOE+00 0.OOOE+00 3.810E+07 2.860E+08 0.OOOE+00 4.670E+07 CO-58 0.OOOE+00 7.940E+06 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.090E+08 0.OOOE+00 1.830E+07 CO-60 0.OOOE+00 2.780E+07 0.OOOE+00 0.000E+00 0.OOOE+00 3.620E+08 0.OOOE+00 6.260E+07 NI-63 1.180E+10 8.350E+08 0,OOOE+00 0.OOOE+00 0.OOOE+00 1.330E+08 0.OOOE+00 4.01OE+08 NI-65 6.770E-01 8.650E-02 0.OOOE+00 0.000E+00 0.OOOE+00 4.690E+00 0.OOOE+00 3.940E-02 CU-64 0.OOOE+00 4.250E+04 0.OOOE+00 1.070E+05 0.OOOE+00 3.290E+06 0.OOOE+00 2.OOOE+04 ZN-65 2.110E+09 7.320E+09 0.OOOE+00 4.680E+09

-, 0.000E+00 3.100E+09 0.OOOE+00 3.410E+09 ZN-69 3.850E-12 7.330E-12 0.OOOE+00 4.790E-12 0.OOOE+00 1.350E-11' 0.OOOE+00 5.130E-13 BR-83 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.790E-01 BR-84 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 0.006E+00 0.OOOE+00 2.880E-23 BR-85 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.000E+00 RB-86 0.OOOE+00 4.730E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 7.OOOE+08 0.OOOE+00 2.220E+09 RB-88 0.OOOE+00 3.890E-45 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.330E-52 0.OOOE+00 2.070E-45 RB-89 0.OOOE+00 7.660E-53 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.170E-61 0.OOOE+00 5.420E-53 SR-89 2.670E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.190E+08 0.OOOE+00 7.660E+07 SR-90 6.610E+10 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1860E+09 0.OOOE+00 1.630E+10 SR-91 5.310E+04 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.410E+05 0.OOOE+00 2.11OE+03 Appendix H Ri Teen Cow Milk - Page 1 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX H R, Teen DoseFactors for use in the Gaseous Dose Calculations Agegroup.

TEEN Palthway:

Grs/Cow/Milk (CMILK)

Units:

m 2.mrem/yr / ýiCi/see; mrem/yr /

(HCam 3 (1.-)

Nuclide,.

Bone Liver Thyroid Kidney

. Lung

-Gilli Skin Total Body SR-92 8.940E-01 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 2.280E+01 0.OOOE+00 3.810E-02 Y-90 1.300E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.070E+06 0.000E+00 3.510E+00 Y-91 1.580E+04 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 6.480E+06 0.000E+00 4.240E+02 Y-91M 1.090E-19 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.170E-18 0.OOOE+00 4.180E-21 Y-92 1.030E-04 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 2.830E+00 0.OOOE+00 2.980E-06 Y-93 4.120E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.260E+04 0.OOOE+00 1.130E-02 ZR-95 1.650E+03 5.200E+02 0.000E+00 7.650E+02 0.OOOE+00 1.200E+06 0.OOOE+00 3.580E+02 ZR-97 7.880E-01 1.560E-01 0.OOOE+00 2.370E-01 0.OOOE+00 4.220E+04 0.OOOE+00 7.190E-02 NB-95 1.410E+05 7.810E+04 0.OOOE+00 7.570E+04 0.OOOE+00 3.340E+08 0.OOOE+00 4.300E+04 MO-99 0.OOOE+00 4.470E+07

-0.OOOE+00 1.020E+08 0.OOOE+00 8.010E+07 0.OOOE+00 8.530E+06 TC-99M 5.760E+00 1.610E+01 0.OOOE+00 2.390E+02 8.920E+00 1.050E+04 0.OOOE+00 2.080E+02 TC-101 4.740E-60 6.750E-60 0.OOOE+00 1.220E-58 4.110E-60 1.150E-66 0.OOOE+00 6.630E-59 RU-103 1.810E+03 0.OOOE+00 0.OOOE+00 6.380E+03 0.OOOE+00 1.510E+05 0.OOOE+00 7.740E+02 RU-105 1.560E-03 0.000E+00 0.OOOE+00 1.970E-02 0.OOOE+00 1.260E+00 0.OOOE+00 6.070E-04 RU-106 3.750E+04 0.000E+00 0.OOOE+00 7.240E+04 0.OOOE+00 1.800E+06 0.000E+00 4.730E+03 AG-110M 9.630E+07 9.110E+07 0.OOOE+00 1.740E+08 0.OOOE+00 2.560E+10 0.OOOE+00 5.540E+07 TE-125M 3.OOOE+07 1.080E+07 8.390E+06 0.OOOE+00 0.OOOE+00 8.860E+07 0.OOOE+00 4.020E+06 TE-127

.1.210E+03 4.290E+02 8.350E+02 4.900E+03 0.OOOE+00 9.340E+04 0.OOOE+00 2.600E+02 TE-127M 8.440E+07 2.990E+07 2.010E+07 3.420E+08 0.OOOE+00 2.100E+08 0.OOOE+00 1.000E+07 TE-129 5.200E-10 1.940E-10 3.720E-10 2.180E-09 0.OOOE+00 2.840E-09 0.OOOE+00 1.270E-10 TE-129M 1.100E+08 4.090E+07 3.550E+07 4.610E+08 0.OOOE+00 4.130E+08 0.OOOE+00 1.740E+07 TE-131 6.580E-33 2.710E-33 5.070E-33 2.880E-32 0.000E+00 5.400E-34 0.OOOE+00 2.060E-33 TE-131M 6.570E+05 3.150E+05 4.740E+05 3.290E+06 0.OOOE+00 2.530E+07 0.OOOE+00 2.630E+05 TE-132 4.290E+06 2.720E+06 2.870E+06 2.610E+07 0.OOOE+00 8.610E+07 0.OOOE+00 2.560E+06 1-130 7.380E+05 2.140E+06 1.740E+08 3.290E+06 0.OOOE+00 1.640E+06 0.OOOE+00 8.530E+05 Appendix H Ri Teen Cow Milk - Page 2 of 3

0 January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX H R, Teen Dose Factors for use in the Gaseous Dose Calculations Agegroup:

TEEN Pathway:..

Grs/Cow/Milk (CMILK) units:

m.mrem/yr / p.Ci/sec;

= :' :

~mrem/yr /(H~/3--3)

SNuclide

  • _
  • Bone Liver Thyroid Kidn'ey Lung1 <

Gilli7..

Skin TotalBody 1-131 5.370E+08 7.520E+08 2.190E+1I 1.290E+09 0.OOOE+00 1.490E+08 0.OOOE+00 4.040E+08 1-132 2.910E-01 7.620E-01 2.570E+01 1.200E+00 0.OOOE+00 3.320E-01 0.OOOE+00 2.740E-01 1-133 7.070E+06 1.200E+07 1.670E+09 2.100E+07 0.OOOE+00 9.070E+06 0.OOOE+00 3.660E+06 1-134 3.580E-12 9.500E-12 1.580E-10 1.500E-11 0.OOOE+00 1.250E-13 0.OOOE+00 3.410E-12 1-135 2.280E+04 5.870E+04 3.780E+06 9.270E+04 0.000E+00 6.510E+04 0.OOOE+00 2.180E+04 CS-134 9.820E+09 2.310E+10 0.OOOE+00 7.340E+09 2.800E+09 2.870E+08 0.OOOE+00 1.070E+10 CS-136 4.480E+08 1.760E+09 0.OOOE+00 9.600E+08 1.510E+08 1.420E+08 0.OOOE+00 1.180E+09 CS-137 1.340E+10 1.780E+10 0.OOOE+00 6.060E+09 2.350E+09 2.530E+08 0.OOOE+00 6.200E+09 CS-138 1.640E-23 3.150E-23 O.OOOE+00 2.330E-23 2.710E-24 1.430E-26 0.OOOE+00 1.580E-23 BA-139 8.170E 5.750E-11 0.OOOE+00 5.420E-11 3.960E-11 7.290E-07 0.OOOE+00 2.380E-09 BA-140 4.850E+07 5.950E+04 0.OOOE+00 2.020E+04 4.OOOE+04 7.480E+07 0.OOOE+00 3.130E+06 BA-141 7.520E-46 5.620E-49 0.OOOE+00 5.210E-49 3.850E-49 1.600E-51 0.OOOE+00 2.510E-47 BA-142 4.790E-80 4.790E-83 0.OOOE+00 4.050E-83 3.190E-83 1.470E-91 0.OOOE+00 2.950E-81 LA-140 8.100E+00 3.980E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.290E+05 0.OOOE+00 1.060E+00 LA-142 3.360E-1 1 1.490E-1 1 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.540E-07 0.000E+00 3.710E-12 CE-141 8.880E+03 5.930E+03 0.OOOE+00 2.790E+03 0.OOOE+00 1.700E+07 0.OOOE+00 6.810E+02 CE-143 7.640E+01 5.560E+04 0.OOOE+00 2.490E+01 0.OOOE+00 1.670E+06 0.OOOE+00 6.210E+00 CE-144 6.580E+05 2.720E+05 0.OOOE+00 1.630E+05 0.OOOE+00 1.660E+08 0.OOOE+00 3.540E+04 PR-143" 2.900E+02 1.160E+02 0.OOOE+00 6.730E+-01 0.OOOE+00 9.540E+05 0.OOOE+00

-1.440E+01 PR-144 1.080E-53 4.430E-54 0.OOOE+00 2.540E-54 0.OOOE+00 1.190E-56 0.000E+00 5.490E-55 ND-147 1.810E+02 1.970E+02 0.OOOE+00 1.160E+02 0.OOOE+00 7.1 10E+05 0.OOOE+00 1.180E+01 W-187 1.190E+04 9.710E+03 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.630E+06 0.OOOE+00 3.400E+03 NP-239 7.010E+00 6.610E-01 0.OOOE+00 2.070E+00 0.OOOE+00 1.060E+05 0.OOOE+00 3.670E-01 Appendix H Ri Teen Cow Milk - Page 3 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX H Ri Teen Dose Factors for use in the Gaseous Dose Calculations Agegroup:

TEEN' Pathway:

Grs/Goat/Milk (GMILK)

Units:

m 2"mrem/yr / pCi/sec; mrem/yr / p.Ci/m 3 (H-3)

Nuclide

-Bone Liver Tiyroid Kidney

Lung, Gilli' Skin Total Body H-3 0.OOOE+00 2.030E+03 2.030E+03 2.030E+03 2.030E+03 2.030E+03 0.OOOE+00 2.030E+03 C-14 4.860E+08 9.720E+07 9.720E+07 9.720E+07 9.720E+07 9.720E+07 0.OOOE+00 9.720E+07 NA-24 5.11OE+05 5.11OE+05 5.110E+05 5.11OE+05 5.11OE+05 5.11OE+05 0.OOOE+00 5.110E+05 P-32 3.780E+10 2.340E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.180E+09 0.OOOE+00 1.470E+09 CR-51 0.OOOE+00 0.OOOE+00 3.330E+03 1.3 1OE+03 8.550E+03 1.O1OE+06 0.000E+00 5.990E+03 MN-54 O.000E+00 1.680E+06 0.OOOE+00 5.020E+05 0.OOOE+00 3.450E+06 0.OOOE+00 3.340E+05 MN-56 0.OOOE+00 8.700E-04 0.OOOE+00 1.100E-03 0.OOOE+00 5.730E-02 0.OOOE+00 1.550E-04 FE-55 5.790E+05 4.11OE+05 0.OOOE+00 0.OOOE+00 2.600E+05 1.780E+05 0.OOOE+00 9.570E+04 FE-59 6.740E+05 1.570E+06 0.OOOE+00 0.OOOE+00 4.960E+05 3.720E+06 0.OOOE+00 6.070E+05 CO-58 0.OOOE+00 9.520E+05 0.OOOE+00 0.OOOE+00
  • 0.000E+00 1.310E+07 0.OOOE+00 2.190E+06 CO-60 0.OOOE+00 3.340E+06 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.350E+07 0.OOOE+00 7.520E+06 NI-63 1.420E+09 1.OOOE+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.590E+07 0.OOOE+00 4.810E+07 NI-65 8.120E-02 1.040E-02 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.630E-01 0.OOOE+00 4.730E-03 CU-64 0.OOOE+00 4.730E+03 0.OOOE+00 1.200E+04 0.000E+00 3.670E+05 0.OOOE+00 2.230E+03 ZN-65 2.530E+08 8.780E+08 0.OOOE+00 5.620E+08 0.OOOE+00 3.720E+08 0.OOOE+00 4.100E+08 ZN-69 4.620E-13 8.800E-13 0.OOOE+00 5.750E-13 0.OOOE+00 1.620E-12 0.OOOE+00 6.160E-14 BR-83 0.OOOE+00 0.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.150E-02 BR-84 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.450E-24 BR-85 0.OOOE+00 0.000E+00 0.OOOE+00 0:000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RB-86 0.OOOE+00 5.670E+08 0.OOOE+00 O.OOOE+00 0.000E+00 8.400E+07 0.OOOE+00 2.670E+08 RB-88 0.OOOE+00 4.670E-46 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.OOOE-53 0.OOOE+00 2.490E-46 RB-89 0.OOOE+00 9.190E-54 0.OOOE+00 0.OOOE+00 O.OOOE+00 1.410E-62 0.OOOE+00 6.500E-54 SR-89 5.620E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.690E+08 0.OOOE+00 1.610E+08 SR-90 1.390E+1 1 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.900E+09 0.OOOE+00 3.430E+10 SR-91 1.120E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.060E+00 5.060E+05 0.OOOE+00 4.440E+03 Appendix H Ri Teen Goat Milk - Page I of 3

0 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

Ri Teen Dose 0

January, 2010 Revision 52 APPENDIX H Factors for use in the Gaseous Dose Calculations 2.

-Agegroup:

TEEN Pathway:

Grs/Goat/Milk (GMILK)

Units:

mI mrem/yr / pCi/sec;

  • * ":-;., i*, '.i-mrem/yr (Hti/

30 -3)

Nuclide Bone

Liver, Thyroid Kidney Lung J Giii Skin Total Body SR-92 1.880E+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 4.780E+01 0.OOOE+00 8.OOOE-02 Y-90 1.560E+01 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 1.290E+05 0.OOOE+00 4.210E-01 Y-91 1.900E+03 0.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 7.770E+05 0.OOOE+00 5.080E+01 Y-91M 1.310E-20 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.200E-19 0.OOOE+00 5.020E-22 Y-92 1.240E-05 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.390E-01 0.OOOE+00 3.580E-07 Y-93 4.940E-02 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.510E+03 0.OOOE+00 1.360E-03 ZR-95 1.980E+02 6.250E+01 0.000E+00 9.180E+01 0.OOOE+00 1.440E+05 0.OOOE+00 4.300E+01 ZR-97 9.460E-02 1.870E-02 0.OOOE+00 2.840E-02 0.OOOE+00 5.070E+03 0.OOOE+00 8.620E-03 NB-95 1.690E+04 9.370E+03 O.OOOE+00 9.080E+03 0.OOOE+00 4.010E+07 0.OOOE+00 5.160E+03 MO-99 0.OOOE+00 5.370E+06

-0.OOOE+00 1.230E+07 0.OOOE+00 9.610E+06 0.OOOE+00 1.020E+06 TC-99M 6.910E-01 1.930E+00 0.OOOE+00 2.870E+61 1.070E+00 1.270E+03 0.OOOE+00 2.500E+01 TC-101 5.690E-61 8.100E-61 0.OOOE+00 1.460E-59 4.930E-61 1.380E-67 0.OOOE+00 7.950E-60 RU-103 2.170E+02 0.OOOE+00 0.OOOE+00 7.660E+02 0.OOOE+00 1.810E+04 0.OOOE+00 9.290E+01 RU-105 1.880E-04 0.OOOE+00 0.000E+00 2.370E-03 0.OOOE+00 1.520E-01 0.OOOE+00 7.290E-05 RU-106 4.500E+03 0.OOOE+00 0.OOOE+00 8.680E+03 0.OOOE+00 2.160E+05 0.OOOE+00 5.670E+02 AG-110M 1.160E+07 1.090E+07 0.OOOE+00 2.080E+07 0.OOOE+00 3.070E+09 O.OOOE+00 6.650E+06 TE-125M 3.600E+06 1.300E+06

'l_010E+06 0.OOOE+00 0.OOOE+00 1.060E+07 0.OOOE+00 4.820E+05 TE-127 1.450E+02 5.150E+01 1.OOOE+02 5.880E+02 0.000E+00 1.120E+04 0.OOOE+00 3.120E+01 TE-127M 1.010E+07 3.590E+06 2.410E+06 4.100E+07 0.OOOE+00 2.520E+07 0.OOOE+00 1.200E+06 TE-129 6.240E-11 2.330E-11 4.460E-11

.2.620E-10 0.OOOE+00 3.410E-10 O.OOOE+00 1.520E-11 TE-129M 1.320E+07 4.900E+06 4.260E+06 5.530E+07 0.OOOE+00 4.960E+07 0.OOOE+00 2.090E+06 TE-131 7.900E-34 3.260E-34 6.090E-34

.3.450E-33 0.000E+00 6.480E-35 0.OOOE+00 2.470E-34 TE-131M 7.880E+04 3.780E+04 5.690E+04 3.940E+05 0.OOOE+00 3.030E+06 0.OOOE+00 3.150E+04 TE-132 5.150E+05 3.260E+05 3A40E+05 3.130E+06 0.000E+00 1.030E+07 0.OOOE+00 3.070E+05 1-130 8.860E+05 2.560E+06 2.090E+08 3.950E+06 0.OOOE+00 1.970E+06 0.OOOE+00 1.020E+06 Appendix H Ri Teen Goat Milk - Page 2 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX H Ri Teen Dose Factors for use in the Gaseous Dose Calculations Agegroup:

TEEN PathwaYy:

Grs/Goat/Milk (GMILK)

Unit:

m 2 imrem/yr / *tCi/sec; C/3 r

mrem/Jr (HCi/m 0-3)

  • Nuclide Bone Liver

-Thyroid Kidney Lung 61 1Gi Skin Total Body 1-131 6.450E+08 9.030E+08 2.630E+11 1.550E+09 0.OOOE+00 1.790E+08 0.OOOE+00 4.850E+08 1-132 3.500E-01 9.150E-01 3.080E+01 1.440E+00 0.OOOE+00 3.980E-01 0.OOOE+00 3.280E-01 1-133 8.480E+06 1.440E+07 2.01OE+09 2.520E+07 0.OOOE+00 1.090E+07 0.OOOE+00 4.390E+06 1-134 4.300E-12 1.140E-11 1.900E-10 1.800E-11 0.OOOE+00 1.500E-13 0.OOOE+00 4.090E-12 1-135 2.740E+04 7.040E+04 4.530E+06 1.11OE+05 0.OOOE+00 7.810E+04 0.OOOE+00 2.610E+04 CS-134 2.940E+10 6.930E+10 0.OOOE+00 2.200E+10 8.410E+09 8.620E+08 0.OOOE+00 3.220E+10 CS-136 1.340E+09 5.290E+09 0.OOOE+00 2.880E+09 4.540E+08 4.260E+08 0.OOOE+00 3.550E+09 CS-137 4.020E+10 5.340E+10 0.OOOE+00 1.820E+10 7.060E+09 7.600E+08 0.OOOE+00 1.860E+10 CS-138 4.920E-23 9.450E-23 0.000E+00 6.980E-23 8.120E-24 4.290E-26 0.OOOE+00 4.730E-23 BA-139 9.800E-09 6.900E-12 0.OOOE+00 6.500E-12 4.750E-12 8.750E-08 0.OOOE+00 2.860E-10 BA-140 5.820E+06 7.130E+03 0.000E+00 2.420E+03 4.800E+03 8.980E+06 0.OOOE+00 3.750E+05 BA-141 9.030E-47 6.740E-50 0.O0OE+00 6.260E-50 4.610E-50 1.920E-52 0.OOOE+00 3.010E-48 BA-142 5.750E-81 5.750E-84 0.OOOE+00 4.860E-84 3.820E-84 1.760E-92 0.OOOE+00 3.540E-82 LA-140 9.720E-01 4.780E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.740E+04 0.OOOE+00 1.270E-01 LA-142 4.030E-12 1.790E-12 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.440E-08 0.OOOE+00 4.450E-13 CE-141 1.070E+03 7.120E+02 0.OOOE+00 3.350E+02 0.OOOE+00 2.040E+06 0.OOOE+00 8.170E+01 CE-143 9.170E+00 6.670E+03 0.OOOE+00 2.990E+00 0.OOOE+00 2.OOOE+05 0.OOOE+00 7.450E-01 CE-144 7.900E+04 3.270E+04 0.OOOE+00 1.950E+04 0.OOOE+00 1.990E+07 0.OOOE+00 4.240E+03 PR-143 3.480E+01 1.390E+01 0.OOOE+00 8.080E+00 0.OOOE+00 1.150E+05 0.OOOE+00 1.730E+00 PR-144 1.300E-54 5.320E-55 0.OOOE+00 3.050E:55 0.OOOE+00 1.430E-57 0.OOOE+00 6.590E-56 ND-147 2.170E+01 2.360E+01 0.OOOE+00 1.390E+01 0.OOOE+00 8.530E+04 0.OOOE+00 1.420E+00 W-187 1.430E+03 1.170E+03 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.150E+05 0.OOOE+00.

4.080E+02 NP-239 8.410E-01 7.930E-02 0.OOOE+00 2.490E-01 0.OOOE+00 1.280E+04 0.OOOE+00 4.410E-02 Appendix H Ri Teen Goat Milk - Page 3 of 3

S January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX H R1 Teen Dose Factors for use in the Gaseous Dose Calculations Agegroup:

TEEN Pathway:

Grs/Cow/Meat (CMEAT)

IUitS:

mZmrem/yr / laCi/sec; C/3 mrem/yr i(H-3)

Nuclide Bone Liver

" Thyroid Kidney Lung

,Giili

-'Skin Total'Body H-3 0.000E+00 1.940E+02 1.940E+02 1.940E+02 1.940E+02 1.940E+02 0.OOOE+00 1.940E+02 C-14 2.040E+08 4.080E+07 4.080E+07 4.080E+07 4.080E+07 4.080E+07 0.000E+00 4.080E+07 NA-24 1.0801-03 1.080E-03 1.080E-03 1.080E-03 1.080E-03 1.080E-03 0.000E+00 1.080E-03 P-32 3.930E+09 2.440E+08 0.OOOE+00 0.000E+00 0.OOOE+00 3.310E+08 0.000E+00 1.530E+08 CR-51 0.000E+00 0.OOOE+00 3.130E+03 1.240E+03 8.050E+03 9.470E+05 0.000E+00 5.640E+03 MN-54 0.OOOE+00 7.OOOE+06 0.OOOE+00 2.090E+06 0.OOOE+00 1.440E+07 0.OOOE+00 1.390E+06 MN-56 0.000E+00 1.070E-53 0.OOOE+00 1.360E-53 0.OOOE+00 7.070E-52 0.OOOE+00 1.910E-54 FE-55 2.380E+08 1.690E+08 0.OOOE+00 0.000E+00 1.070E+08 7.310E+07 0.000E+00 3.940E+07 FE-59 2.120E+08 4.950E+08 0.OOOE+00 0.OOOE+00 1.560E+08 1.170E+09 0.OOOE+00 1.910E+08 CO-58 0.OOOE+00 1.410E+07 0.OOOE+00 0.OOOE+00 0.000E+00 1.940E+08 0.OOOE+00 3.240E+07 CO-60 0.OOOE+00 5.830E+07 0.OOOE+00 0.000E+00 0.000E+00 7.600E+08 0.OOOE+00 1.310E+08 NI-63 1.520E+10 1.070E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.710E+08 0.OOOE+00 5.150E+08 NI-65 1.880E-52 2.410E-53 0.OOOE+00 0.000E+00 0.OOOE+00 1.300E-51 0.OOOE+00 1.160E-53 CU-64 0.000E+00 2.210E-07 0.OOOE+00 5.600E-07 0.OOOE+00 1.720E-05 0.OOOE+00 1.040E-07 ZN-65 2.500E+08 8.690E+08 0.OOOE+00 5.560E+08 0.OOOE+00 3.680E+08 0.OOOE+00 4.050E+08 ZN-69 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 BR-83 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00 5.070E-57 BR-84 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 RB-86 0.OOOE+00 4.070E+08 0.006E+00 0.OOOE+00 0.OOOE+00 6.020E+07 0.OOOE+00 1.910E+08 RB-88 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.006E+00 RB-89 0.0001+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 SR-89 2.550E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.030E+07 0.OOOE+00 7.290E+06 SR-90 8.050E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 2.260E+08 0.OOOE+00 1.990E+09 SR-91 1.280E-10 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 5.800E-10 0.OOOE+00 5.090E-12 Appendix H Ri Teen Cow Meat - Page I of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX H Ri Teen Dose Factors for use in the Gaseous Dose Calculations Agegroup:

TEEN Pathway:

Grs/Cow/Meat (CMEAT)

units m2.mrem/yr / +/-Ci/sec; mrem/yr / Ci/m H3)

Nuclide Bone Liver

-Thbyroid, Kidney

Lung,

--GilliI Skin Total Body SR-92 9.880E-50 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 2.520E-48 0.OOOE+00 4.210E-51 Y-90 9.060E+01 0.000E+00 0.OOOE+00 0.000E+00 0.OOOE+00 7.470E+05 0.000E+00 2,440E+00 Y-91 9.540E+05 0.OOOE+00 0.000E+00 O.000E+00 0.OOOE+00 3.910E+08 0.000E+00 2.560E+04 Y-91M 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00 0.000E+00 Y-92 1.280E-39 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 3.520E-35 0.000E+00 3.710E-41 Y793 3.960E-12 0.OOOE+00 0.000E+00 O.OOOE+00 0.OOOE+00 1.210E-07 0.OOOE+00 1.090E-13 ZR-95 1.500E+06 4.730E+05 0.OOOE+00 6,950E+05 0.OOOE+00 1.090E+09 0.OOOE+00 3.250E+05 ZR-97 1.720E-05 3.410E-06 0.OOOE+00 5.170E-06 0.OOOE+00 9.230E-01 0.OOOE+00 1.570E-06 NB-95 1.790E+06 9.950E+05 0.OOOE+00 9.650E+05 0.OOOE+00 4.260E+09 0.OOOE+00 5.480E+05 MO-99 0.OOOE+00 8.270E+04 0.OOOE+00 1.890E+05 0.OOOE+00 1.480E+05 0.OOOE+00 1.580E+04 TC-99M 3.530E-21 9.850E-21 0.OOOE+00 1.470E-19 5.470E-21 6.470E-18 0.OOOE+00 1.280E-19 TC-101 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RU-103 8.570E+07 0.OOOE+00 0.OOOE+00 3.020E+08 0.000E+00 7.160E+09 0.OOOE+00 3.660E+07 RU-105 4.830E-28 0.OOOE+00 0.OOOE+00 6.090E-27 0.OOOE+00 3.900E-25 0.OOOE+00 1.880E-28 RU-106 2.360E+09 0.OOOE+00 0.OOOE+00 4.550E+09 0.OOOE+00 1.130E+11 0.000E+00 2.970E+08 AG-110M 5.060E+06 4.790E+06 0.OOOE+00 9.130E+06 0.OOOE+00 1.340E+09 0.000E+00 2.910E+06 TE-125M 3.030E+08 1.090E+08 8.470E+07 0.OOOE+00 0.OOOE+00 8.940E+08 0.OOOE+00 4.050E+07 TE-127 1.800E-10 6.380E-11 1.240E-10 7.290E-10 0.OOOE+00 1.390E-08 0.OOOE+00 3.870E-11 TE-127M 9.410E+08 3.340E+08 2.240E+08 3.820E+09 0.OOOE+00 2.350E+09 0.OOOE+00 1.120E+08 TE-129 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 TE-129M 9.500E+08 3.530E+08 3.070E+08 3.970E+09 0.OOOE+00 3..570E+09 0.OOOE+00 1.500E+08 TE-131 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0,000E+00 TE-131M 3.760E+02 1.800E+02 2.71 OE+02 1.880E+03 0.OOOE+00 1.450E+04 0.OOOE+00 1.500E+02 TE-132 1.160E+06 7.360E+05 7.750E+05 7.060E+06 0.OOOE+00 2.330E+07 0.000E+00 6.920E+05 1-130 1.700E-06 4.910E-06 4.OOOE-04 7.560E-06 0.OOOE+00 3.770E-06 0.000E+00 1.960E-06 Appendix H Ri Teen Cow Meat - Page 2 of 3 S

January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX H R! Teen Dose Factors for use in the Gaseous Dose Calculations Agegrou4p:'

TEEN Pathway:

Grs/Cow/Meat (CMEAT)

Units:

In2 mrem/yr /

"Wi/sec;

  • -.Ult:;

mZmrem/yr /

.Ci/see;-3

Nucelide, B~one.

Liver Thyroid kidney fLuing

<7 illi<

<Skip Total Body 1-131 8.920E+06 1.250E+07 3.650E+09 2.150E+07 0.OOOE+00 2.470E+06 0.OOOE+00 6.710E+06 1-132 5.660E-59 1.480E-58 4.990E-57 2.330E-58 0.OOOE+00 6.450E-59 0.OOOE+00 5.320E-59 1-133 3.050E-01 5.180E-01 7.230E+01 9.090E-01 0.OOOE+00 3.920E-0 1 0.OOOE+00 1.580E-01 1-134 0.OOOE+00 0.009E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 1-135 3.600E-17 9.260E-17 5.960E-15 1.460E-16 0.OOOE+00 1.030E-16 0.OOOE+00 3.430E-17 CS-134 5.230E+08 1.230E+09 0.OOOE+00 3.910E+08 1.490E+08 1.530E+07 0.OOOE+00 5.710E+08 CS-136 9.400E+06 3.700E+07 0.000E+00 2.010E+07 3.170E+06 2.980E+06 0.000E+00 2.480E+07 CS-137 7.240E+08 9.630E+08 0.000E+00 3.280E+08 1.270E+08 1.370E+07 0.OOOE+00 3.360E+08 CS-138 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 BA-139 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 BA-140 2.380E+07 2.910E+04 0.OOOE+00 9.870E+03 1.960E+04 3.660E+07 0.OOOE+00 1.530E+06 BA-141 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 BA-142 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 LA-140 3.050E-02 1.500E-02 0.OOOE+00 0.OOOE+00 0.OOOE+00 8.610E+02 0.OOOE+00 3.990E-03 LA-142 2.870E-92 1.280E-92 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.880E-88 0.OOOE+00 3.180E-93 CE-141 1.180E+04 7.870E+03 0.OOOE+00 3.710E+03 0.OOOE+00 2.250E+07 0.000'E+00 9.040E+02 CE-143 1.690E-02 1.230E+01 0.OOOE+00 5.510E-03 0.OOOE+00 3.690E+02 0.OOOE+00 1.370E-03 CE-144 1.230E+06 5.080E+05 0.000E+00 3.040E+05 0.OOOE+00 3.090E+08 0.000E+00 6.600E+04 PR-143 1.760E+04 7.040E+03 0.OOOE+00 4.090E+03 0.OOOE+00 5.800E+07 0.OOOE+00 8.780E+02 PR-144 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 ND-147

.6.230E+03 6.770E+03 0.000E+00 3.980E+03 0.OOOE+00 2.440E+07 0.OOOE+00 4.060E+02 W-187 1.730E-02 1.410E-02 0.OOOE+00 0.OOOE+00 0.OOE+00 3.820E+00 0.000E+00 4.940E-03 NP-239 2.260E-01 2.140E-02 0.OOOE+00 6.700E-02 0.OOOE+00 3.440E+03 0.OOOE+00 1.190E-02 Appendix H Ri Teen Cow Meat - Page 3 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX H R1 Teen Dose Factors for use in the Gaseous Dose Calculations Agegroup:

TEEN Pathway:

Vegetation (VEG)

Units:

n m2.mrem/yr / PtCi/sec; mrem/__r /

_tCi/m3 (11-3)

Nuclfide

~Bonie Liver hroid

kidney, Lupngý Gill[

Skin~ ToitalBody H-3 0.000E+00 2.590E+03 2.590E+03 2.590E+03 2.590E+03 2.590E+03 0.OOOE+00 2.590E+03 C-14 3.690E+08 7.380E+07 7.380E+07 7.380E+07 7.380E+07 7.380E+07 0.OOOE+00 7.380E+07 NA-24 2.390E+05 2.390E+05 2.390E+05 2.390E+05 2.390E+05 2.390E+05 0.OOOE+00 2.390E+05 P-32 1.610E+09 9.970E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.350E+08 0.OOOE+00 6.240E+07 CR-51 0.OOOE+00 0.OOOE+00 3.430E+04 1.350E+04 8.810E+04 1.040E+07 0.OOOE+00 6.170E+04 MN-54 0.OOOE+00 4.540E+08 0.OOOE+00 1.360E+08 0.OOOE+00 9.320E+08 0.OOOE+00 9.010E+07 MN-56 0.OOOE+00 1.420E+01 0.OOOE+00 1.800E+01 0.OOOE+00

  • 9.360E+02 0.OOOE+00 2.530E+00 FE-55 3.260E+08 2.310E+08 0.OOOE+00 0.OOOE+00 1.470E+08 1.OOOE+08 0.OOOE+00 5.390E+07 FE-59 1.790E+08 4.190E+08 0.OOOE+00 0.OOOE+00 I.320E+08 9.900E+08 0.000E+00 1.620E+08 CO-58 0.OOOE+00 4.360E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.010E+08 0.OOOE+00 1.000E+08 CO-60 0.OOOE+00 2.490E+08 0.000E+00 0.OOOE+00 0.OOOE+00 3.240E+09 0.OOOE+00 5.600E+08 NI-63 1.610E+16 1.130E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.810E+08 0.OOOE+00 5.450E+08 NI-65 5.720E+01 7.310E+00 0.OOOE+00

" 0.OOOE+00 0.OOOE+00 3.970E+02 0.OOOE+00 3.330E+00 CU-64 0.OOOE+00 8.340E+03 0.OOOE+00 2.1 10E+04 0.OOOE+00 6.470E+05 0.OOOE+00 3.920E+03 ZN-65 4.240E+08 1.470E+09 0.OOOE+00 9.420E+08 0.OOOE+00 6.230E+08 0.OOOE+00 6.870E+08 ZN-69 5.140E-06 9.800E-06 0.000E+/-00E 6.400E-06 0.OOOE+00 4.810E-05 0.OOOE+00 6.860E-07 BR-83 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.910E+00 BR-84 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.250E-11 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RB-86 0.OOOE+00 2.740E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.050E+07 0.OOOE+00 1.290E+08 RB-88 0.000E+00 3.170E-22 O.OOOE+00 O.OOOE+00 0.OOOE+00 2.720E-29 O.OOOE+00 1.690E-22 RB-89 0.00OE+00 3.500E-26 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.360E-35 0.OOOE+00 2.470E-26 SR-89 1.510E+10 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.800E+09 0.OOOE+00 4.340E+08 SR-90 7.510E+1I1 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.110E+10 0.OOOE+00 1.850E+11 SR-91 2.850E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.290E+06 0.OOOE+00 1.130Et,04 Appendix H Ri Teen Vegetation - Page 1 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX H R! Teen Dose Factors for use in the Gaseous Dose Calculations 2

Agegrap:*

TEEN Pathway:

Vegetation (VEG)

Units:

In mrem/yr / J4Ci/sec;

    • i:

G.?:*, mrem/yr / tCi/m3 (-1-3)

Nuclide Bone Liver

'thyroid Kidney LugGilli<

Skin Total Body7 SR-92 3.970E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.010E+04 0.OOOE+00 1.690E+01 Y-90 1.240E+04 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 1.020E+08 0.OOOE+00 3.350E+02 Y-91 7.840E+06 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.210E+09 0.000E+00 2.100E+05 Y-91M 4.860E-09 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.290E-07 0.OOOE+00 1.860E-10 Y-92 8.600E-01 0.OOOE+00 0.OOOE+00 0,OOOE+00 0.OOOE+00 2.360E+04 0.OOOE+00 2.490E-02 Y-93 1.590E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.860E+06 0.OOOE+00 4.360E+00 ZR-95 1.720E+06 5.430E+05 0.OOOE+00 7.980E+05 0.OOOE+00 1.250E+09 0.OOOE+00 3.730E+05 ZR-97 3.120E+02 6.180E+01 0.OOOE+00 9.370E+01 0.OOOE+00 1.670E+07 0.OOOE+00 2.850E+01 NB-95 1.920E+05 1.070E+05 0.OOOE+00 1.030E+05 0.OOOE+00 4.560E+08 0.OOOE+00 5.870E+04 MO-99 0.OOOE+00 5.650E+06

-0.OOOE+00 1.290E+07 0.OOOE+00 1.010E+07 0.OOOE+00 1.080E+06 TC-99M 2.740E+00 7.630E+00 0.OOOE+00 1.140E+02 4.240E+00 5.010E+03 0.OOOE+00 9.890E+01 TC-101 7.640E-31 1.090E-30 0.OOOE+00 1.970E-29 6.620E-31 1.860E-37 0.OOOE+00 1.070E-29 RU-103 6.820E+06 0.OOOE+00 0.OOOE+00 2.400E+07 0.OOOE+00 5.700E+08 0.OOOE+00 2.920E+06 RU-105 5.OOOE+01 0.OOOE+00 0.OOOE+00 6.310E+02 0.000E+00 4.040E+04 0.OOOE+00 1.940E+0!-.-<

RU-106 3.100E+08 0.OOOE+00 0.OOOE+00 5.970E+08 0.OOOE+00 1.480E+10 0.OOOE+00 3.900E+07 --

AG-110M 1.520E+07 1.430E+07 0.OOOE+00 2.740E+07 0.OOOE+00 4.030E+09 0.OOOE+00 8.720E+06 TE-125M 1.480E+08 5.340E+07 4.140E+07 0.OOOE+00 0.OOOE+00 4.370E+08 0.000E+00 1.980E+07 TE-127 5.330E+03 1.890E+03 3.680E+03 2.160E+04 0.OOOE+00 4.120E+05 0.OOOE+00 1.150E+03 TE-127M 5.510E+08 1.960E+08 1.310E+08 2.240E+09 0.000E+00 1.370E+09 0.OOOE+00 6.560E+07

-TE-129 7.140E-04 2.660E-04 5.100E-04 3.OOOE-03 0.OOOE+00 3.910E-03 0.OOOE+00 1.740E-04 TE-129M 3.620E+08 1.340E+08 1.170E+08' 1.510E+09 0.OOOE+00 1.360E+09 0.OOOE+00 5.730E+07 TE-131 1.390E-15 5.750E-16 1.070E-15 6.100E-15 0.OOOE+00 1.140E-16 0.000E+00 4.360E-16 TE-131M 8.440E+05 4.050E+05 6.090E+05 4.220E+06 0.OOOE+00 3.250E+07 0.OOOE+00 3.380E+05 TE-132 3.910E+06 2.470E+06 2.610E+06 2.370E+07 0.OOOE+00 7.840E+07 0.OOOE+00 2.330E+06 1-130 3.510E+05 1.010E+06 8.280E+07 1.560E+06 0.OOOE+00 7.800E+05 0.OOOE+00 4.050E+05 Appendix H Ri Teen Vegetation - Page 2 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX H Ri Teen Dose Factors for use in the Gaseous Dose Calculations

,ýAgegroup:_'

TEEN

"-'Pathway:

Vegetation (VEG) 2nits:

.mrem/yr / tCi/sec; mrem/yr / itCi/m 3 (1H-3)

N...lide B

.<.Bon.e <Liver)

Thyroid Kidney Lung Gilli Skin Total Body 1-131 7.690E+07 1.080E+08 3.140E+10 1.850E+08 0.OOOE+00 2.130E+07 0.OOOE+00 5.780E+07 1-132 5.190E+01 1.360E+02 4.580E+03 2.140E+02 0.OOOE+00 5.920E+01 0.000E+00 4.880E+01 1-133 1.940E+06 3.290E+06 4.590E+08 5.760E+06 0.OOOE+00 2.490E+06 0.OOOE+00 1.OOOE+06 1-134 8.720E-05 2.310E-04 3.850E-03 3.640E-04 0.OOOE+00 3.050E-06 0.OOOE+00 8.310E-05 1-135 3.520E+04 9.070E+04 5.830E+06 1.430E+05 0.OOOE+00 1.OOOE+05 0.OOOE+00 3.360E+04 CS-134 7.100E+09 1.670E+10 0.OOOE+00 5.310E+09 2.030E+09 2.080E+08 0.OOOE+00 7.750E+09 CS-136 4.370E+07' 1.720E+08 0.OOOE+00 9.370E+07 1.480E+07 1.380E+07 0.OOOE+00 1.160E+08 CS-137 1.010E+10 1.350E+10 0.OOOE+00 4.590E+09 1.780E+09 1.920E+08 0.OOOE+00 4.690E+09 CS-138 3.610E-11 6.940E-11 0.OOOE+00 5.120E-11 5.960E-12 3.150E-14 0.OOOE+00 3.470E-11 BA-139 2.690E-02 1.890E-05 0.OOOE+00 1.780E-05 1.300E-05 2.400E-01 0.OOOE+00 7.830E-04 BA-140 1.380E+08 1.690E+05 0.OOOE+00 5.740E+04 1.140E+05 2.130E+08 0.OOOE+00 8.900E+06 BA-141 1.080E-21 8.040E-25 0.OOOE+00 7.460E-25 5.500E-25 2.290E-27 0.OOOE+00 3.590E-23 BA-142 5.490E-39 5.490E-42 0.OOOE+00 4.640E-42 3.650E-42 1.680E-50 0.OOOE+00 3.380E-40 LA-140 1.810E+03 8.880E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.100E+07 0.OOOE+00 2.360E+02 LA-142 1.850E-04 8.240E-05 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.510E+00 0.OOOE+00 2.050E-05 CE-141 2.830E+05 1.890E+05 0.000E+00 8.890E+04 O.OOOE+00 5.400E+08 0.OOOE+00 2.170E+04 CE-143 9.330E+02 6.790E+05 0.OOOE+00 3.040E+02 0.OOOE+00 2.040E+07 0.000E+00 7.580E+01 CE-144 5.270E+07 2.180E+07 0.000E+00 1.300E+07 0.OOOE+00 1.330E+i10 0.OOOE+00 2.830E+06

.PR-143 7.OOOE+04 2.800E+04 0.OOOE+00 1.630E+04 0.OOOE+00 2.300E+08 0.OOOE+00 3.490E+03 PR-144 2.900E-26 1.190E-26 0.OOOE+00 6.800E-27 0.OOOE+00 3.190E429 0.OOOE+00 1.476E-27 ND-147 3.620E+04 3.940E+04 0.OOOE+00 2.310E+04 0.OOOE+00 1.420E+08 0.OOOE+00 2.360E+03 W-187 3.540E+04 2.880E+04 0.OOOE+00 0.000E+00 0.OOOE+00 7.800E+06 0.OOOE+00 1.010E+04 NP-239 1.390E+03 1.310E+02 0.OOOE+00 4.100E+02 0.OOOE+00 2.100E+07 0.OOOE+00 7.260E+01 Appendix H Ri Teen Vegetation - Page 3 of 3

0 January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX H Ri Teen Dose Factors for use in the Gaseous Dose Calculations Agegroup:

TEEN Pathway:

Inhalation (INHL)

Units:,

mrem/yr / ýtCi/m 3

-Nuclide, LB j

4 iver ThyIroi a Kiony (INL Gi.. i S.ki.

Total dy H-3 O.OOOE+00 1.270E+03 1.270E+03 1.270E+03 1.270E+03 1.270E+03 0.OOOE+00 1.270E+03 C-14.

2.600E+04 4.870E+03 4.870E+03 4.870E+03 4.870E+03 4.870E+03 0.OOOE+00 4.870E+03 NA-24 1.380E+04 1.380E+04 1.380E+04 1.380E+04 1.380E+04 1.380E+04 0.OOOE+00 1.380E+04 P-32 1.890E+06 1.100E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 9.280E+04 0.OOOE+00 7.160E+04 CR-51 0.000E+00 0.OOOE+00 7.500E+01 3.070E+01 2.100E+04 3.OOOE+03 0.000E+00 1.350E+02 MN-54 0.OOOE+00 5.11OE+04 0.OOOE+00 1.270E+04 1.980E+06 6.680E+04 0.OOOE+00 8.400E+03 MN-56 0.OOOE+00 1.700E+00 0.OOOE+00 1.790E+00 1.520E+04 5.740E+04 0.OOOE+00 2.520E-01 FE-55 3.340E+04 2.380E+04 0.OOOE+00 0.OOOE+00 1.240E+05 6.390E+03 0.OOOE+00 5.540E+03 FE-59 1.590E+04 3.700E+04 0.OOOE+00 0.OOOE+00 1.530E+06 1.780E+05 O.OOOE+00 1.430E+04 CO-58 0.OOOE+00 2.070E+03 0.OOOE+00 0.OOOE+00 1.340E+06 9.520E+04 0.OOOE+00 2.780E+03 CO-60 0.OOOE+00 1.510E+04 0.OOOE+00 0.OOOE+00 8.720E+06 2.590E+05 0.OOOE+00 1.980E+04 NI-63 5.800E+05 4.340E+04 0.OOOE+00 O.OOOE+00 3.070E+05 1.420E-04 0.OOOE+00 1.980E+04 NI-65--

2.180E+00 2.930E-01 0.OOOE+00 0.OOOE+00 9.360E+03 3.670E+04 0.OOOE+00 1.270E-01 CU-64 0.OOOE+00 2.030E+00 0.OOOE+00 6.410E+00 1.11OE+04 6.140E+04 0.600E+00 8.480E-01 ZN-65 3.860E+04 1.340E+05 0.OOOE+00 8.640E+04 1.240E+06 4.660E+04 0.OOOE+00 6.240E++/-04 ZN-69 4.830E-02

, 9.200E-02 0.OOOE+00 6.020E-02 1.580E+03 2.850E+02 0.OOOE+00 6.460E-03 BR-83 0.OOOE÷00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.440E+02 BR-84 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.330E+02 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 1.830E+01 RB-86 0.OOOE+00 1.900E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.770E+04 0.OOOE+00 8.400E+04 RB-88 0.OOOE+00 5.460E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.920E-05 0.OOOE+00 21720E+02 RB-89 0.OOOE+00 3.520E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.380E-07 0.OOOE+00 2.330E+02 SR-89 4.340E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.420E+06 3.710E+05 0.OOOE+00 1.250E+04 SR-90 1.080E+08 0.000E+00 0.000E+00 0.OOOE+00 1.650E+07 7.650E+05 0.OOOE+00 6.680E+06 SR-91 8.800E+01 0.OOOE+00 O.OOOE+00 0.OOOE+00 6.070E+04 2.590E+05 0.OOOE+00 3.510E+00 Appendix H Ri Teen Inhalation - Page 1 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX H R_ Teen Dose Factors for use in the Gaseous Dose Calculations Agegrioup:i TEEN P~athway :

Inhalation (INHL)

Units:

mrem/yr /.Ci/m 3 Nuclide

ýBone.

Liver~

Thyroid Kidney Lkng

~

G'illi Skin A Total Body SR-92 9.520E+00 0.OOOE+00 O.000E+00 0.000E+00 2.740E+04 1.190E+05 0.000E+00 4.060E-01 Y-90 2.980E+03 0.000E+00 0..OOOE+00 0.000E+00 2.930E+05 5.590E+05 0.000E+00 8.000E+01 Y-91 6.610E+05 0.000E+00 0.OOOE+00 0.000E+00 2.940E+06 4.090E+05 0.000E+00 1.770E+04 Y-91M 3.700E-01 0.000E+00 0.000E+00 0.OOOE+00 3.200E+03 3.020E+01 0.000E+00 1.420E-02 Y-92 1.470E+01 0.000E+00 0.000E+00 0.OOOE+00 2.680Et04 1.650E+05 0.000E+00 4.290E-01 Y-93 1.350E+02 0.000E+00 0.OOOE+00 0.000E+00 8.320E+04 5.790E+05 0.000E+00 3.720E+00 ZR-95 1.460E+05 4.580E+04 0.000E+00 6.740E+04 2.690E+06 1.490E+05 0.000E÷00 3.150E+04 ZR-97 1.380E+02 2.720E+01 0.000E+00 4.120E+01 1.300E+05 6.300E+05 0.OOOE+00 1.260E+01 NB-95 1.860E+04 1.030E+04 0.OOOE+00 1.000E+04 7.510E+05 9.680E+04 0.000E+00 5.660E+03 MO-99 0.OOOE+00 1.690E+02 0.OOOE+00 4.11 OE+02 1.540E+05 2.690E+05 0.000E+00 3.220E+01 TC-99M 1.380E-03 3.860E-03 0.000E+00 5.760E-02 1.150E+03 6.130E+03 0.000E+00 4.990E-02 TC-101 5.920E-05 8.400E-05 0.000E+00 1.520E-03 6.670E+02 8.720E-07 0.000E+00 8.240E-04 RU-103 2.100E+03 0.000E+00 0.000E+00 7.430E+03 7.830E+05 1.090E+05 0.000E+00 8.960E+02 RU-105 1.120E+00 0.000E+00 0.OOOE+00 1.410E+00 1.820E+04 9.040E+04 0.000E+00 4.340E-01 RU-106 9.840E+04 0.000E+00 0.000E+00 1.900E+05 1.610E+07 9.600E+05 0.000E+00 1.240E+04 AG-110M 1.380E+04 1.310E+04 0.000E+00 2.500E+04 6.750E+06 2.730E+05 0.000E+00 7.990E+03 TE-125M 4.880E+03 2.240E+03 1.400E+03 0.OOOE+00 5.360E+05 7.500E+04 0.OOOE+00 6.670E+02 TE-127 2.010E+00 9.120E-0 1 1.420E+00 7.280E+00

1. 120E+04 8.080E+04 0.000E+00 4.420E-01 TE-127M 1.800E+04 8.160E+03 4.380E+03 6.540E+04 1.660E+06 1.590E+05 0.000E+00 2.180E+03 TE-129 7.100E-02 3.380E-02 5.180E-02 2.660E-01 3.300E+03 1.620E+03 0.OOOE+00 1.760E-02 TE-129M 1.390E+04 6.580E+03 4.580E+03 5.190E+04 1.980E+06 4.050E+05 0.000E+00 2.250E+03 TE-131 1.580E-02 8.320E-03 1.240E-02 6.180E-02 2.340E+03 1.510E+01 0.000E+00

-5.040E-03 TE-131M 9.840E+01 6.010E+01 7.250E+01 4.390E+-02 2.380E+05 6.210E+05 0.000E+00 4.020E+01 TE-132 3.600E+02 2.900E+02 2.460E+02 1.950E+03 4.490E+05 4.630E+05 0.000E+00 2.190E+02 11-130 6.240E+03 1.790E+04 1.490E+06 2.750E+04 0.OOOE+00 9.120E+03 0.000E+00 7.170E+03 Appendix H Ri Teen Inhalation-Page 2 of 3 0

S

0 January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

Ri Teen Dose APPENDIX H Factors for use in the Gaseous Dose Calculations Agegroup:

TEEN Pathway:

Inhalation (INHL)

U1nits:

mrem/yr / gtCi/m 3 3Nuclide

~Bone Liver

Thyrqtd Kidneyr Lung Gilli

~

Skin

~.Total Bodyý,,

1-131 3.540E+04 4.910E+04 1.460E+07 8.400E+04 0.OOOE+00 6.490E+03 0.OOOE+00 2.640E+04 1-132 1.590E+03 4.380E+03 1.510E+05 6.920E+03 O.OOOE+00 1.270E+03 0.OOOE+00 1.580E+03 1-133 1.220E+04 2.050E+04 2.920E+06 3.590E+04 0.OOOE+00 1.030E+04 0.OOOE+00 6.220E+03 1-134 8.880E+02 2.320E+03 3.950E+04 3.660E+03 0.OOOE+00 2.040E+01 0.OOOE+00 8.400E+02 1-135 3.700E+03 9.440E+03 6.210E+05 1.490E+04 0.OOOE+00 6.950E+03 0.OOOE+00 3.490E+03 CS-134 5.020E+05 1.130E+06 0.000E+00 3.750E+05 1.460E+05 9.760E+03 0.000E+00 5.490E+05 CS-136 5.150E+04 1.940E+05 0.006E+00 1.100E+05 1.780E+04 1.090E+04 0.OOOE+00 1.370E+05 CS-137 6.700E+05 8.480E+05 0.OOOE+00 3.040E+05 1.210E+05 8'.480E+03 0.OOOE+00 3.11OE+05 CS-138 4.660E+02 8.560E+02 0.OOOE+00 6.620E+02 7.870E+01 2.700E-01 0.OOOE+00 4.460E+02 BA-139 1.340E+00 9.440E-04 0.OOOE+00 8.880E-04 6.460E+03 6.450E+03 0.OOOE+00 3.900E-02 BA-140 5.470E+04 6.700E+01 0.OOOE+00 2.280E+01 2.030E+06 2.290E+05-0.OOOE+00 3.520E+03 BA-141 1.420E-01 1.060E-04 0.OOOE+00 9.840E-05 3.290E+03 7.460E-04 0.OOOE+00 4.740E-03 BA-142 3.700E-02 3.700E-05 0.OOOE+00 3.140E-05 1.910E+03 4.790E-10 0.OOOE+00 2.270E-03 LA-140 4.790E+02 2.360E+02 0.OOOE+00 0.OOOE+00 2.140E+05 4.870Eq-05 0.OOOE+00 6.260E+01 LA-142 9.600E-01 4.250E-01 0.OOOE+00 0.OOOE+00 1.020E+04

.1.200E+04 0.OOOE+00 1.060E-0i CE-141 2.840E+04 1.900E+04 0.OOOE+00 8.880E+03 6.140E+05 1.260E+05 0.OOOE+00 2.170E+03 CE-143 2.660E+02 1.940E+02 0.OOOE+00 8.640E+01 1.300E+05 2.550E+05 0.OOOE+00 2.160E+01 CE-144 4.890E+06 2.020E+06 0.OOOE+00 1.210E+06 1.340E+07 8.640E+05 0.000E+00 2.620E+05 PR-143 1.340E+04 5.310E+03 0.OOOE+00 3.090E+03 4.830E+05 2.140E+05 0.OOOE+00 6.620E+02 PR-144 4.300E-02 1.760E-02 0.OOOE+00 1.010E-02 1.750E+03 2.350E-04 0.OOOE+00 2.180E-03 ND-147 7.860E+03 8.560E+03 0.OOOE+00 5.020E+03 3.720E+05 1.820E+05 0.OOOE+00 5.130E+02 W-187 1.20.OE+0 1 9.760E+00 0.OOOE+00 0.000E+00 4.740E+04 i.770E+05 0.OOOE+00 3.430E+00 NP-239 3.380E+02 3.190E+01 O.OOOE+00 1.000E+02 6.490E+04 1.320E+05 0.OOOE+00 1.770E+01 Appendix H Ri Teen Inhalation - Page.3 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX H Ri Teen Dose Factors for use in the Gaseous Dose Calculations Agegroup:

TEEN Pathway:

Ground Plane Deposition (GPD)

Units:

i 2 mrem/yr

ý/iCi/sec

'Nuclide on Liver Thnyrmid Kidney Lung Gilli mkiemy T H-3 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00 0.OOOE+00 0.OOOE+00 C-14 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.000E+00 0.000E+00 0.OOOE+00 NA-24 1.190E+07 1.190E+07 1.190E+07 1.190E+07 1.190E+07 1.190E+07 1.390E+07 1.190E+07 P-32 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 CR-51 4.660E+06 4.660E+06 4.660E+06 4.660E+06 4.660E+06 4.660E+06 5.510E+06 4.660E+06 MN-54 1.390E+09 1.390E+09 1.390E+09 1.390E+09 1.390E+09 1.390E+09 1.630E+09 1.390E+09 MN-56 9.020E+05 9.020E+05 9.020E+05 9.020E+05 9.020E+05 9.020E+05 1.070E+06 9.020E+05 FE-55

.0.000E+00 0.OOOE+00 0.000E+00 0.006E+00 0.000E+00 0.000E+00 0.OOOE+00 0.OOOE+00 FE-59 2.730E+08 2.730E+08 2.730E+08 2.730E+08 2.730E+08 2.730E+08 3.210E+08 2.730E+08 CO-58 3.790E+08 3.790E+08 3.790E+08 3.790E+08 3.790E+08 3.790E+08 4.440E+08 3.790E+08 CO-60

-2.150E+10 2.150E+10 2.150E+10 2.150E+10 2.150E+10 2.150E+10 2.530E+10 2.150E+10 NI-63 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.OOOE+00 NI-65 2.970E+05 2.970E+05 2.970E+05 2.970E+05 2.970E+05 2.970E+05 3.450E+05 2.970E+05 CU-64 6.070E+/-05 6.070E+05 6.070E+05 6.070E+05 6.070E+05 6.070E+05 6.880E+05 6.070E+05 ZN-65 7.470E+08 7.470E+08 1.470E+08 7.470E+08 7.470E+08 7.470E+08 8.590E+08 7.470E+08 ZN-69 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00' 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 BR-83 4.870E+03 4870E+03 4.870E+03 4.870E+03 4.870E1+03 4.870E+03 7.080E+03 4.870E+03 BR-84 2.030E+05 2.030E+05 2.030E+05 2.030E+05 2.030E+05 2.030E+05 2.360E+05 2.030E+05 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 RB-86 8.990E+06 8.990E+06 8.990E+06 8.990E+06 8.990E+06 8.990E+06 1.030E+07 8.990E+06 RB-88 3.310E+04 3.310E+04 3.310E+04 3.310E+04 3.310E+04 3.310E+04 3.780E+04 3.310E+04 RB-89 1.230E+05 1.230E+05 1.230E+05 1.230E+05 1.230E+05 1.230E+05 1.480E+05 1,230E+05 SR-89 2.160E+04 2.160E+04 2.160E+04 2.160E+04 2.160E+04 2.160E+04 2.510E+04 2.160E+04 SR-90 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00 0.000E+00 0.OOOE+00 0.OOOE+00 SR-91 2.150E+06 2.150E+06 2.150E+06 2.150E+06 2.150E+06 2.150E+06 2.510E+06 2.150E+06 Appendix H Ri Teen Ground Plane Deposition - Page 1 of 3 i

0 January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX H Ri Teen Dose Factors for use in the Gaseous Dose Calculations Agegroup:

TEEN "Pathiway:-

Ground Plane Deposition (GPD)

Un its;:

m2 mrem/yr / pCi/sec Nuclide Bone Liver Thyroid Kidney' Lung' Gilli 7

Skin Total Body SR-92 7.770E+05 7.770E+05 7.770E+05 7.770E+05 7.770E+05 7.770E+05 8.630E+05 7.770E+05 Y-90 4.490E+03 4.490E+03 4.490E+03 4.490E+03 4.490E+03 4.490E+03 5.3 1OE+03 4.490E+03 Y-91 1.070E+06 1.070E+06 1.070E+06 1.070E+06 1.070E+06 1.070E+06 1.210E+06 1.070E+06 Y-91M 1.000E+05 1.000E+05 1.OOOE+05 1.000E+05 1.000E+05 1.000E+05 1.160E+05 1.000E+05 Y-92 1.800E+05 1.800E+05 1.800E+05 1.800E+05 1.800E+05 1.800E+05 2.140E+05 1.800E+05 Y-93 1.830E+05 1.830E+05 1.830E+05 1.830E+05_-

1.830E+05 1.830E+05 2.510E+05 1.830E+05 ZR-95 2.450E+08 2.450E+08 2.450E+08 2.450E+08 2.450E+08 2.450E+08 2.840E+08 2.450E+08 ZR-97 2.960E+06 2.960E+06 2.960E+06 2.960E+06 2.960E+06 2.960E+06 3.440E+06 2.960E+06 NB-95 1.370E+08 1.370E+08 1.370E+08 1.370E+08 1.370E+08 1.370E+08 1.610E+08 1.370E+08 MO-99 3.990E+06 3.990E+06 3.990E+06 3.990E+06 3.990E+06 3.990E+06 4.630E+06 3.990E+06 TC-99M 1.840E+05 1.840E+05 1.840E+05 1.840E+05 1.840E+05 1.840E+05 2.11OE+05 1.840E+05 TC-101 2.040E+04 2.040E+04 2.040E+04 2.040E+04 2.040E+04 2.040E+04 2.260E+04 2.040E+04 RU-103 1.080E+08 1.080E+08 1.080E+08 1.080E+08 1.080E+08 1.080E+08 1.260E+08 1.080E+08 RU-105 6.360E+05 6.360E+05 6.360E+05 6.360E+05 6.360E+05 6.360E+05 7.210E+05 6.360E+05 RU-106 4.220E+08 4.220E+08 4.220E+08 4.220E+08 4.220E+08 4.220E+08 5.070E+08 4.220E+08 AG-i IOM 3.440E+09 3.440E+09 3.440E+09 3.440E+09 3.440E+09 3.440E+09 4.010E+09 3.440E+09 TE-125M 1.550E+06 1.550E+06 1.550E+06 1.550E+06 1.550E+06 1.550E+06 2.130E+06 1.550E+06 TE-127 2.980E+03 2.980E+03 2.980E+03 2.980E+03 2.980E+03 2.980E+03 3.280E+03 2.980E+03 TE-127M 9.160E+04 9.160E+04 9.160E+04 9.160E+04 9.160E+04 9.160E+04 1.080E+05 9.160E+04 TE-129 2.620E+04 2.620E+04 2.620E+04 2.620E+04 2.620E+04 2.620E+04 3'100E+04 2.620E+04 TE-129M 1.980E+07 1.980E+07 1.980E+07 1.980E+07 1.980E+07 1.980E+07 2.31 OE+07 1.980E+07 TE-131 2.920E+04 2.920E+04 2.920E+04 2.920E+04 2.920E+04 2.920E+04 3.450E+07 2.920E+04 TE-131M 8.030E+06 8.030E+06 8.030E+06 8.030E+06 8.030E+06 8.030E+06 9.460E+06 8.030E+06 TE-132 4.230E+06 4.230E+06 4.230E+06 4.230E+06 4.230E+06 4.230E+06 4.980E+06 4.230E+06 11-130 5.510E+06 5.510E+06 5.510E+06 5.510E+06 5.510E+06 5.510E+06 6.690E+06 5.510E+06 Appendix H Ri Teen Ground Plane Deposition - Page 2 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX H Ri Teen Dose Factors for use in the Gaseous Dose Calculations

.Agegroup:

TEEN Pathway:

Ground Plane Deposition (GPD)

Units:"'ý m 2mrem/yr / gCi/sec Nuclide Bone Liver Thyroid Kidney Lung

  • Gilli Skin' Total Body 1-131 1.720E+07 1.720E+07 1.720E+07 1.720E+07 1.720E+07 1.720E+07 2.090E+07 1.720E+07 1-132 1.250E+06 1.250E+06 1.250E+06 1.250E+06 1.250E+06 1.250E+06 1.470E+06 1.250E+06 1-133 2.450E+06 2.450E+06 2.450E+06 2.450E+06 2.450E+06 2.450E+06 2.980E+06 2.450E+06 1-134 4.470E+05 4.470E+05 4.470E+05 4.470E+05 4.470E+05 4.470E+05 5.300E+05 4.470E+05 1-135 2.530E+06 2.530E+06 2.530E+06 2.530E+06 2.530E+06 2.530E+06 2.950E+06 2.530E+06 CS-134 6.860E+09 6.860E+09 6.860E+09 6.860E+09 6.860E+09 6.860E+09 8.OOOE+09 6.860E+'09 CS-136 1.510E+08 1.510E+08 1.510E+08 1.510E+08 1.510E+08 1.510E+08 1.710E+08--

1.510E+08 CS-137 1.030E+10 1.030E+10 1.030E+10 1.030E+10 1.030E+10 1.030E+10 1.200E+10 1.030E+10 CS-138 3.590E+05 3.590E+05 3.590E+05 3.590E+05 3.590E+05 3.590E+05 4.100E+05 3.590E+05 BA-139 1.060E+05 1.060E+05 1.060E+05 1.060E+05 1.060E+05 1.060E+05 1.190E+05 1.060E+05 BA-140 2.050E+07 2.050E+07 2.050E+07 2.050E+07 2.050E+07 2.050E+07 2.350E+07 2.050E+07 BA-141 4.170E+04

.4.170E+04 4.170E+04 4.170E+04 4.170E+04 4.170E+04 4.750E+04 4.170E+04 BA-142 4.490E+04 4.490E+04 4.490E+04 4.490E+04 4.490E+04 4.490E+04 5.110E+04 4.490E+04 LA-140 1.920E+07 1.920E+07 1.920E+07 1.920E+07 1.920E+07 1.920E+07 2.180E+07 1.920E+07 LA-142 7.600E+05 7.600E+05 7.600E+05 7.600E+05 7.600E+05 7.600E+05 9.120E+05 7.600E+05 CE-141 1.370E+07 1.370E+07 1.370E+07 1.370E+07 1.370E+07 1.370E+07 1.540E+07 1.370E+07 CE-143 2.310E+06 2.310E+06 2.310E+06 2.310E+06 2.310E+06 2.310E+06 2.630E+06 2.310E+06 CE-144 6.950E-07 6.950E+07 6.950E+07 6.950E+07 6.950E+07 6.950E+07 8.040E+07 6.950E+07 PR-143 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 PR-144 1.830E+03 1.830E+03 1.830E+03 1.830E+03 1.830E+03 1.830E+03 2.110E+03 1.830E+03 ND-147 8.390E+06 8.390E+06 8.390E+06 8.390E+06 8.390E+06 8.390E+06 1.010E+07 8.390E+06 W-187 2.350E+06 2.350E+06 2.350E+06 2.350E+06 I 2.350E+06 2.350E+06 2.730E+06-2.350E+06 NP-239 1.710E+06 1.710E+06 1.710E+06 1.710E+06 1.710E+06 1.710E+06 1.980E+06 1.710E+06 I,

Appendix H Ri Teen Ground Plane Deposition - Page 3 of 3 0

January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX I Ri Child Dose Factors for use in the Gaseous Dose Calculations

-Agegi~oup:

CHILD Patfiwaiy:

Grs/Cow/Milk (CMILK)

UnIits:mme/r/'isc 3

______mrem/yr C/m (H-3 NulieBone Liver' Thyri Ki ney

~

Ln, ih Skin"'

TotalI Body H-3 0.OOOE+00 1.570E+03 1.570E+03 1.570E+03 1.570E+03 1.570E+03 0.OOOE+00 1.570E+03 C-14 1.190E+09 2.390E+08 2.390E+08 2.390E+08 2.390E+08 2.390E+08 0.OOOE+00 2,390E+08 NA-24 8.850E+06 8.850E+06 8.850E+06 8.85013+06 8.850E+06 8.850E+06 0.OOOE+00 8.850E+06 P-32 7.780E+10 3.640E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.150E+09 0.OOOE+00 3.OOOE+/-09 CR-51 0.OOOE+00 0.OOOE+00 5.650E+04 1.540E+04 1.030E+05 5.400E+06 0.OOOE+00 1.020E+05 MN-54 0.000E+00 2.100E+07 0.OOOE+00 5.880E+06 0.OOOE+00 1.760E+/-07 0.OOOE+00 5.590E+0'6 MIN-56 0.OOOE+00 1,260E-02 0.OOOE+00 1.530E-02 0.006E+00 1.830E+00 0.OOOE+00 2.860E-03 FE-55

1. 120E+08 5.930E+07 0.000E+00 0.OOOE+/-00 3.350E+07
1. 100E+07 0.OOOE+00 1.840E+07 FE-59 1.200E+08 1.950E+/-08 0.OOOE+00 0.OOOE+00 5.640E+/-07 2.030E+08 0.OOOE+/-00 9.690E+07 CO-58 0.OOOE+00 1.210E+/-07 0.OOOE+00 0.OOOE+00 0.OOOE+/-00 7.070E+07 0.OOOE+/-00 3.710E+07 CO-60 0.600E+00 4.320E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.390E+08 0.OOOE+00 1.270E+08 NI-63 2.960E+ 10 1.590E+09 0.OOOE+00 0.000E+00 0.OOOE+00 1.070E+08 0.OOOE+00 1.0IOE+09 NI-65 1.660E+00 1.560E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.910E+01 0.OOOE+00 9.100E-02 CU-64 0.000E+00 7.460E+04 0.OOOE+00 1.800E+05 0.OOOE+00 3.500E+06 0.OOOE+00 4.5 10E+04 ZN-65 4.1 30E+09
1. 100E+/-10 0.OOOE+00 6.940E+09 0.OOOE+00 1.930E+09 0.OOOE+00 6.850E+09-ZN-69 9.460E-12 1.370E-1 1 0.OOOE+00 8.300E-12 0.OOOE+00 8.620E-10 0.OOOE+00 1.260E-12 BR-83 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+/-00 0.OOOE+00 4.400E-01 BR-84 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+/-00 0.OOOE+00 0.OOOE+00 0.000E+ 00 6.5.10E-23 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE-f-0 0.OOOE+00 0.OOOE+00 0.OOOE+00 RB-86 0.OOOE+00 8.770E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.640E+08 0.000E+00 5.390E+09 RB3-88 0.OOOE+00 7.160E-45 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.5 1 OE-46 0.OOOE+00 4.970E-45 RB-89 0.OOOE+00 1.340E-52 0.OOOE+00 0.OOOE+00 0.OOOE+00
1. 170EI-54 0.OOOE+00
1. 190E-52 SR-89 6.620E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.560E+08 0.OOOE+00 1.890E+08 SR-90 1.120E+11 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+0O 1.510E+09 0.OOOE+00 2.830E+10 SR-91 1.300E+05 0.OOOE+00 0.OOOE+00 0.060E+00 0.OOOE+00 2.880E+05 0.OOOE+00 4.920E+03 Appendix I Ri Child Cow Milk - Page 1 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX I Ri Child Dose Factors for use in the Gaseous Dose Calculations 2

Agegroup:

CHILD Pathway:

Grs/Cow/Milk (CMILK)

Units.:.

m mrem/yr /,Ci/sec;

.mrem/yr

/ tCi/m3 (*--3)

Nuclide, Bone "

Liver Thrid Kidney Lung Gilli

,-Skin TotalBody SR-92 2.180E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.130E+01 0.000E+00 8.750E-02 Y-90 3.220E+02 0.OOOE+00 0.OOOE+00 O.OOOE+00 0.OOOE+00 9.170E+05 0.OOOE+00 8.620E+00 Y-91 3.900E+04 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.200E+06 0.OOOE+00 1.040E+03 Y-91M 2.670E-19 0.000E+00 0.000E+00 0.000E+00 0.000E+00 5.240E-16 0.000E+00 9.730E-21 Y-92 2.530E-04 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 7.3101E+00 0.OOOE+00 7.240E-06 Y-93 1.010E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.510E+04 0.OOOE+00 2.780E-02 ZR-95 3.830E+03 8.420E+02 0.OOOE+00 1.210E+03 0.OOOE+00 8.790E+05 0.OOOE+00 7.500E+02 ZR-97 1.920E+00 2.770E-01 0.OOOE+00 3.980E-01 0.OOOE+00 4.200E+04 0.OOOE+00 1.640E-01 NB-95 3.180E+05 1.240E+05 0.OOOE+00 1.160E+05 0.OOOE+00 2.290E+08 0.OOOE+00 8.840E+04 MO-99 0.OOOE+00 8.140E+07 0.OOOE+00 1.740E+08 0.OOOE+00 6.730E+07 0.OOOE+00 2.010E+07 TC-99M 1.320E+01 2.590E+01 0.OOOE+00 3.760E+02 1.320E+01 1.470E+04 0.OOOE+00 4.290E+02 TC-101 1.160E-59 1.220E-59 0.OOOE+00 2.080E-58 6.440E-60 3.870E-59 0.OOOE+00 1.540E-58 RU-103 4.280E+03 0.OOOE+00 0.OOOE+00 1.080E+04 0.OOOE+00 1.11OE+05 0.OOOE+00 1.650E+03 RU-105 3.820E-03 0.OOOE+00 0.OOOE+00 3.360E-02 0.OOOE+00 2.490E+00 0.OOOE+00 1.390E-03 RU-106 9.240E+04 0.OOOE+00 0.OOOE+00 1.250E+05 0.OOOE+00 1.440E+06 0.OOOE+00 1.150E+04 AG-1 IOM 2.090E+08 1.410E+08 0.OOOE+00 2.630E+08 0.OOOE+00 1.680E+10 0.OOOE+00 1.130E+08 TE-125M 7.380E+07 2.OOOE+07 2.070E+07 0.OOOE+00 0.OOOE+00 7.120E+07 0.OOOE+00 9.840E+06 TE-127 2.980E+03 8.020E+02 2.060E+03 8.470E+03 0.OOOE+00 1.160E+05 0.OOOE+00 6.380E+02 TE-127M 2.080E+08 5.600E+07 4.970E+07 5.930E+08 0.OOOE+00 1.680E+08 0.OOOE+00 2.470E+07 TE-129 1.280E-09 3.580E-10 9.160E-10 3.750E-09 0.OOOE+00 7.990E-08 0.OOOE+00 3.050E-10 TE-129M 2.710E+08 7.580E+07 8.750E+07 7.970E+08 0.000E+00 3.310E+08 0.OOOE+00 4.210E+07 TE-131 1.620E-32 4.920E-33 1.240E-32 4.890E-32 0.000E+00 8.490E-32 0.OOOE+00 4.8101E-33 TE-131M 1.600E+06 5.530E+05 1.140E+06 5.350E+06 0.OOOE+00 2.240E+07 0.OOOE+00 5.890E+05 TE-132 1.020E+07 4.530E+06 6.600E+06 4.210E+07 0.OOOE+00 4.570E+07 0.OOOE+00 5.480E+06 1-130 1.730E+06 3.490E+06 3.840E+08 5.220E+06 0.000E+00 1.630E+06 0.OOOE+00 1.800E+06 Appendix I Ri Child Cow Milk - Page 2 of 3 0

0

January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX I R1 Child Dose Factors for use in the Gaseous Dose Calculations Agegroup:

CHILD Pathway:

Grs/Cow/Milk (CMILK)

Units:

m2.mrem/yr / ptCi/sec; mrem/yr / CiM H-3

- Njdide, Bone LiVer

'thyroid Kidneys Lung GAilli Skin Total Bd 1-131 1.300E+09 1.310E+09 4.330E+11 2.150E+09 0.OOOE+00 1.170E+08 0.OOOE+00 7.450E+08 1-132 6.890E-01 1.270E+00 5.870E+01 1.940Et00 0.OOOE+00 1.490E+00 0.000E+00 5.820E-01 1-133 1.720E+07 2.120E+07 3.940E+09 3.540E+07 0.OOOE+00 8.560E+06 0.OOOE+00 8.030E+06 1-134*-

8.480E-12 1.570E-11 3.620E-10 2.410E-11 0.000E+00 1.040E-11 0.OOOE+00 7.250E-12 1-135 5.400E+04 9.720E+04 8.610E+06 1.490E+05 0.OOOE+00 7.400E+04 0.OOOE+00 4.600E+04, CS-134 2.260E+10 3.720E+10 0.OOOE+00 1.150E+10 4.130E+09 2.OOOE+08 O.OOOE+00 7.840E+09 CS-136 1.010E+09 2.780E+09 0.OOOE+00 1.480E+09 2.210E+08 9.770E+07 0.000E+00 1.800E+09 CS-137 3.220E+10 3.090E+10 0.OOOE+00 1.010E+10 3.620E+09 1.930E+08

-0.OOOE+00 4.550E+09 CS-138 3.980E-23 5.530E-23 0.000E+00 3.890E-23 4.190E-24 2.550E-23 0.OOOE+00 3.510E-23 BA-139 2.010E-07 1.070E-10 0.000E+00 9.360E-11 6.300E-11 1.160E-05 0.OOOE+00 5.820E-09 BA-140 1.170E+08 1.030E+05 0.OOOE+00 3.340E+04 6.120E+04 5.930E+07 0.OOOE+00 6.840E+06 BA-141 1.850E-45 1.040E-48 0.000E+00 8.960E-49 6.090E-48 1.050E-45 0.OOOE+00 6.020E-47 BA-142 1.150E-79 8.3101E-83 0.OOOE+00 6.720E-83 4.890E-83 1.510E-81 0.OOOE+00 6.450E-81 LA-140 1.940E+01 6.780E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.890E+05 0.OOOE+00 2.290E+00 LA-142 8.100E-11 2.580E-11 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.120E-06 0.OOOE+00 8.090E-12 CE-141.

2.190E+04 1.090E+04 0.OOOE+00 4.780E+03 0.OOOE+00 1.360E+07 0.OOOE+00 1.620E+03 CE-143 1.870E+02 1.020E+05 0.OOOE+00 4.260E+01 0.OOOE+00 1.490E+06 0.OOOE+00 1.470E+01 CE-144 1.620E+06 5.090E+05 0.OOOE+00 2.820E+05 0.OOOE+00 1.330E+08 0.OOOE+00 8.660E+04 PR-143 7.180E+02 2.160E+02 0.OOOE+00 1.170E+02 0.OOOE+00 7.750E+05 0.OOOE+00 3.560E+01 PR-144 2.680E-53 8.290E-54 0.OOOE+00 4.380E-54 0.OOOE+00 1.780E-50 0.OOOE+00 1.350E-54 ND-147 4.450E+02 3.600E+02 0.OOOE+00 1.980E+02 0.000E+00 5.700E+05 0.OOOE+00 2.790E+01 W-187 2.890E+04 1.710E+04 0.OOOE+00 0.OOOE+00 0.000E+00 2.400E+06 0.OOOE+00 7.670E+03 NP-239, 1.720E+01 1.240E+00 0.OOOE+00 3.580E+00 0.OOOE+00 9.170E+04 0.OOOE+00 8.710E-01 Appendix I Ri Child Cow Milk - Page 3 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX I Ri Child Dose Factors for use in the Gaseous Dose Calculations Agegroup:

CHILD Pathway:

Grs/Goat/Milk (GMILK)

Units:

m2 mrem/yr / ýCi/sec;

____mrem/yr

/ [tCi/m 3 (H-3)

Niicide>

Bone Liv~er Thyr~oid Kidney Luong Gilli Skini Total'Body~

H-3 O.OOOE+00 3.200E+03 3.200E+03 3.200E+03 3.200E+03 3.200E+03 0.OOOE+00 3.200E+03 C-14 1.190E+09 2.390E+08 2:390E+08 2.390E+08 2.390E+08 2.390E+08 0.OOOE+00 2.390E+08 NA-24 1.060E+06 1.060E+06 1.060E+06 1.060E+06 1.060E+06 1.060E+06 0.OOOE+00 1.060E+06 P-32 9.330E+10 4.370E+09 0.OOOE+00 0,OOOE+00 0.OOOE+00 2.580E+09 0.OOOE+00 3.600E+09 CR-51 0.OOOE+00 0.OOOE+00 6.780E+03 1.850E+03 1.240E+04 6.480E+05 0.OOOE+00 1.220E+04 MN-54 0.OOOE+00 2.520E+06 0.OOOE+00 7.060E+/-05 0.OOOE+00 2.11OE+06 0.OOOE+00 6.700E+05 MN-56 0.OOOE+00 1.520E-03 0.OOOE+00 1.840E-03 0.OOOE+00 2.200E-01 0.OOOE+00 3.430E-04 FE-55 1.450E+06 7.710E+05 0.OOOE+00 0.OOOE+00 4.360E+05-1.430E+05 0.OOOE+00 2.390E+05 FE-59 1.560E+06 2.530E+06 0.OOOE+00 0.OOOE+00 7.330E+05 2.630E+06 0.OOOE+00 1.260E+06 CO-58 0.OOOE+00 1.450E+06 0.OOOE+00 0.OOOE+00 0.OOOE+00 8.490E+06 0.OOOE+00 4.450E+06 CO-60 0.OOOE+00 5.180E+06 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.870E+07 0.OOOE+00 1.530E+07 NI-63 3.560E+09 1.900E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.280E+07 0.OOOE+00 1.210E+08 NI-65 1.990E-01 1.870E-02 0.OOOE+00 0.OOOE+00

- 0.OOOE+00 2.290E+00 0.OOOE+00 1.090E-02 CU-64 0.OOOE+00 8.320E+03 0.OOOE+00 2.010E+04 0.OOOE+00 3.900E+05

-0.OOOE+00 5.020E+03 ZN-65 4.960E+08 1.320E+09 0.OOOE+00 8.330E+08 0.OOOE+00 2.320E+08 0.OOOE+00 8.220E+08 ZN-69 1.140E-12 1.640E-12 0.OOOE+00 9.960E-13 0.OOOE+00 1.030E-10 0.OOOE+00 1.520E-13 BR-83 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.280E-02 BR-84 0.OOOE+00 0.OOOE+00 0.OOOE+00

- 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 7.820E-24 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RB-86 0.000E+00 1.050E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.770E+07 0.OOOE+00 6.470E+08 RB-88 0.OOOE+00 8.590E-46 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.210E-47 0.OOOE+00 5.970E-46 RB-89 0.OOOE+00 1.610E-53 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.410E-55 0.OOOE+00 1.430E-53 SR-89 1.390E+10 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 5.380E+08 0.OOOE+00 3.970E+08 SR-90 2.350E+1 1 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.160E+09 0.000E+00 5.950E+10 SR-91 2.740E+05 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 6.040E+05 0.OOOE+00 1.030E+04 Appendix I Ri Child Goat Milk - Page 1 of 3 0

b

0.

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX I R1 Child Dose Factors for use in the Gaseous Dose Calculations Agegroup:,.

CHILD PathWay:

Grs/Goat/Milk (GMILK)

Units:

m2 mrem/yr / ptCi/sec; S-

"mrem/yr*

C/m 3 -

Nucide Bone....

Live" Th(roid Kidney Lung

-Gilli Skin Total Body SR-92 4.580E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 8.680E+01 0.OOOE+00 1.840E-01 Y-90 3.870E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 1.100E+05 0.OOOE+00 1.030E+00 Y-91 4.680E+03 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.240E+05 0.OOOE+00 1.250E+02 Y-91M 3.210E-20 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.280E-17 0.000E+00 1.170E-21 Y-92 3.040E-05 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 8.770E-01 0.OOOE+00 8.690E Y-93 1.210E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.810E+03 0.000E+00 3.330E-03 ZR-95 4.600E+02 1.010E+02 0.OOOE+00 1.450E+02 0.OOOE+00 1.050E+05 0.OOOE+00 9.OOOE+01 ZR-97 2.300E-01 3.330E-02 0.OOOE+00 4.780E-02 0.OOOE+00 5.040E+03 0.OOOE+00 1.960E-02 NB-95 3.810E+04 1.490E+04 0.OOOE+00 1.400E+04 0.OOOE+00 2.750E+07 0.OOOE+00 1.060E+04 MO-99 0.OOOE+00 9.760E+06 0.OOOE+00 2.090E+07 0.OOOE+00 8.080E+06 0.OOOE+00 2.420E+06 TC-99M 1.590E+00 3.11OE+00 0.OOOE+00 4.520E+01 1.580E+00 1.770E+03 0.OOOE+00 5.150E+01 TC-101 1.400E-60 1.460E-60 0.OOOE+00 2.490E-59 7.720E-61 4.640E-60 0.OOOE+00 1.850E-59 RU-103 5.140E+02 0.OOOE+00 0.OOOE+00 1.290E+03 0.OOOE+00 1.330E+04 0.OOOE+00 1.980E+02 RU-105 4.580E-04 0.OOOE+00 0.OOOE+00 4.030E-03 0.OOOE+00 2.990E-01 0.OOOE+00 1.660E RU-106 1.110E+04 0.OOOE+00 0.OOOE+00 1.500E+04 0.OOOE+00 1.720E+05 0.OOOE+00 1.380E+03 AG-110M 2.510E+07 1.690E+07 0.OOOE+00 3.150E+07 0.OOOE+00 2.010E+09 0.000E+00 1.350E+07 TE-125M 8.850E+06 2.400E+06 2.480E+06 O.OOOE+00 0.OOOE+00 8.540E+06 0.OOOE+00 1.180E+06 TE-127 3.570E+02 9.630E+01 2.470E+02 1.020E+03 0.OOOE+00 1.390E+04 0.OOOE+00 7.660E+61 TE-127M 2.500E+07 6.720E+06 5,970E+06 7.120E+07 0.OOOE+00 2.020E+07 0.OOOE+00 2.960E+06 TE-129 1.540E-10 4.300E-11 1.100E-10 4.510E-10 0.OOOE+00 9.590E-09 0.000E+00 3.660E-11 TE-129M 3.260E+07 9.090E+06 1.050E+07 9.560E+07 0.OOOE+00 3.970E+07 0.OOOE+00 5.060E+06 TE-131 1.940E-33 5.910E-34 1.480E-33 5.860E-33 0.OOOE+00 1.020E-32 0.OOOE+00 5.710E-34 TE-131M 1.920E+05 6.640E+04 1.360E+05 6.420E+05 0.OOOE+00 2.690E+06 0.OOOE+00 7.060E+04 TE-132 1.230E+06 5.440E+05 7.920E+05 5.050E+06 0.OOOE+00 5.480E+06 0.OOOE+00 6.570E+05 1-130 2.070E+06 4.190E+06 4.610E+-08 6.260E+06 0.000E+00 1.960E+06 0.OOOE+00 2.160E+06 Appendix I Ri Child Goat Milk - Page 2 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX I R: Child Dose Factors for use in the Gaseous Dose Calculations Agegroup:

CHILD Pathway:

Grs/Goat/Milk (GMILK)

Units:'

m 2.mrem/yr / PCi/sec; mrem/yr / jtCi/m 3 (H-3)

-Nuclide Bone

" Liver Thyroid -

Kidney Lung

.Gilli Skin Total Body 1-131 1.560E+09 1.570E+09 5.200E+1 1 2.580E+09 0.OOOE+00 1.400E+08 0.000E+00 8.940E+08 1-132 8.270E-01 1.520E+00 7.050E+01 2.330E+00 0.OOOE+00 1.790E+00 0.OOOE+00 6.990E-01 1-133 2.060E+07 2.550E+07 4.730E+09 4.250E+07 0.OOOE+00 1.030E+07 0.OOOE+00 9.640E+06 1-134 1.020E-11 1.890E-11 4.350E-10 2.890E-11 0.000E+00 1.250E-11 0.OOOE+00 8.700E-12 1-135 6.480E+04 1.170E+05 1.030E+07 1.790E+05 0.000E+00 8.880E+04 0.000E+00 5.520E+04 CS-134 6.790E+10 1.11OE+l 0.OOOE+00 3.450E+10 1.240E+10 6.010E+08 0.OOOE+00 2.350E+10 CS-136 3.030E+09 8.340E+-09 0.OOOE+00 4.440E+09 6.630E+08 2.930E+08 0.000E+00 5.400E+09 CS-137 9.670E+10 9.260E+10 0.OOOE+00 3.020E+10 1.090E+10 5.800E+08.

0.OOOE+00 1.370E+10 CS-138 1.190E-22 1.660E-22 0.OOOE+00 1.170E-22 1.260E-23 7.640E-23 0.000E+00 1.050E-22 BA-139 2.410E-08 1.290E-11 0.OOOE+00 1.120E-11 7.560E-12 1.390E-06 0.OOOE+00 6.980E-10 BA-140

\\ 1.410E+07 1.230E+04 0.000E+00 4.010E+03 7.340E+03 7.120E+06 0.000E+00 8.200E+05 BA-141 2.220E-46 1.240E-49 0.OOOE+00 1.080E-49 7.300E-49 1.270E-46 0.000E+00 7.230E-48 BA-142 1.390E-80 9.970E-84 0.OOOE+00 8.070E-84 5.870E-84 1.810E-82 0.OOOE+00 7.740E-82 LA-140 2.330E+00 8.140E-01 0.000E+00 0.OOOE+00 0.OOOE+00 2.270E+04 0.000E+00 2.740E-01 LA-142 9.730E-12 3.100E-12 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.140E-07 0.OOOE+00 9.710E-13 CE-141 2.620E+03 1.310E+03 0.OOOE+00 5.740E+02 0.OOOE+00 1.630E+06 0.OOOE+00 1.940E+02 CE-143 2.250E+01 1.220E+04 0.OOOE+00 5.120E+00 0.OOOE+00 1.790E+05 0.OOOE+00 1.770E+00 CE-144 1.950E+05-6.11OE+04 0.OOOE+00 3.380E+04 0.OOOE+00 1.590E+07 0.OOOE+00 1.040E+04 PR-143 8.620E+01 2.590E+÷1 0.OOOE+00 1.400E+01 0.OOOE+00 9.300E+04 0.OOOE+00 4.280E+00 PR-144 3.220E-54 9.950E-55 0.OOOE+00 5.260E-55 0.OOOE+00 2.140E-51 0.OOOE+00 1.620E-55 ND-147 5.330E+01 4.320E+01 0.OOOE+00 2.370E+01 0.OOOE+00 6.850E+04 0.OOOE+00 3.350E+00 W-187 3.470E+03 2.050E+03 0.OOOE+00 0.OOOE+00 0.00OE+00 2.880E+05 0.OOOE+00 9.210E+02 NP-239 2.070E+00 1.490E-01 0.000E+00 4.300E-01 0.000E+00 1.1OOE+04 0.OOOE+00 1.040E-01 Appendix I Ri Child Goat Milk - Page 3 of 3 10

.0 January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX I Ri Child Dose Factors for use in the Gaseous Dose Calculations Agegroup:

CHILD Pathway:

Grs/Cow/Meat (CMEAT)

Units:

m2.mrem/yr / pCi/sec;

_/Ci/m3

--3)

Nuclide -

Bone

LiWr, Thyroid

' Kidney Lung Gilli Skin Total Body.

H-3 0.OOOE+00 2.340E+02 2.340E+02 2.340E+02 2.340E+02 2.340E+02 0.OOOE+00 2.340E+02 C-14 3.830E+08 7.670E+07 7.670E+07 7.670E+07 7.670E+07 7.670E+07 0.OOOE+00 7.670E+07 NA-24 1.720E-03 1.720E-03 1.720E-03 1.720E-03 1.720E-03 1.720E-03 0.OOOE+00 1.720E-03 P-32 7.420E+09 3.470E+08 0.OOOE+00 0.OOOE+00 0.000E+00 2.050E+08 0.OOOE+00 2.860E+08 CR-51 0.OOOE+00 0.OOOE+00 4.880E+03 1.330E+03 8.91OE+03 4.660E+05 0.OOOE+00 8.790E+03 MN-54 0.OOOE+00 8.010E+06 0.OOOE+00 2.250E+06 0.OOOE+00 6.720E+06 0.OOOE+00 2.130E+06 MN-56 0.OOOE+00 1.430E-53 0.OOOE+00 1.730E-53 0.OOOE+00 2.070E-51 0.000E+00 3.230E-54 FE-55 4.570E+08 2.420E+08 0.OOOE+00 0.OOOE+00 1.370E+08 4.490E+07 0.OOOE+00 7.5 1OE+07 FE-59 3.760E+08 6.090E+08 0.OOOE+00 0.OOOE+00 1.770E+08 6.340E+08 0.OOOE+00 3.030E+08 CO-58 0.OOOE+00 1.640E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 9.580E+07 0.OOOE+00 5.020E+07 CO-60 O.OOOE+00 6.930E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.840E+08 0.OOOE+00 2.040E+08 NI-63 2.910E+10 1.560E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.050E+08 0.OOOE+00 9.910E+08 NI-65 3.520E-52 3.310E-53 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.060E-51 0.OOOE+00 1.930E-53 CU-64 0.OOOE+00 2.970E-07 0.OOOE+00 7.180E-07 0.OOOE+00 1.390E-05 0.OOOE+00 1.800E ZN-65 3.750E+08 1.000E+09 0.OOOE+00 6.300E+08 0.OOOE+00 1.760E+08 0.OOOE+00 6.220E+08 ZN-69 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 BR-83 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 9.520E-57 BR-84 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.00OE+00 RB-86 0.OOOE+00 5.770E+08 0.OOOE+00 0.OOOE+00 O.OOOE+00 3.710E+07 0.OOOE+00 3.550E+08 RB-88 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 RB-89 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 SR-89 4.820E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.870E+07 0.OOOE+00 1.380E+07 SR-90 1.040E+10 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.400E+08 0.OOOE+00 2.640E+09 SR-91 2.400E-10 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 5.300E-10 0.OOOE+00 9.050E-12 Appendix I Ri Child Cow Meat - Page 1 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX I Ri Child Dose Factors for use in the Gaseous Dose Calculations Agegroup:

CHILD Pathway':

Grs/Cow/Meat (CMEAT)

Units:

m 2.mrem/yr / gtCi/sec;

"________r_________

_______mrem/yr

( HtCi/m 3 0--3)

Nuclide Bone Liver Thyroid Kidne"y Lung Gilli Skin Total Body, SR-92 1.850E-49 0.000E+00 0.000E+00 0.000E+00 0.OOOE+00 3.490E-48 0.000E+00 7.400E-51 Y-90 1.710E+02 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 4.880E+05 0.000E+00 4.590E+00 Y-91 1.800E+06 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 2.400E+08 0.000E+00 4.820E+04 Y-91M 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 o.000E+00 0.OOOE+00 0.000E+00 0.OOOE+00 Y-92 2.410E-39 O.OOOE+00 0.000E+00 0.000E+00 0.000E+00 6.960E-35 0.000E+00 6.890E-41 Y-93 7.440E-12 0.OOOE+00 0.000E+00 0.000E+00 O.OOOE+00 1.11OE-07 0.000E+00 2.040E-13 ZR-95 2.660E+06 5.850E+05

- 0.000E+00 8.380E+05 0.000E+00 6.110E+08 0.OOOE+00 5.210E+05 ZR-97 3.200E-05 4.630E-06 0.000E+00 6.650E-06 0.OOOE+00 7.010E-01 0.OOOE+00 2.730E-06 NB-95 3.100E+06 1.210E+06 0.000+E00 1.130E+06 0.OOOE+00 2.230E+09 0.000E+00 8.620E+05 MO-99 0.000E+00 1.150E+05 0.000E+00 2.460E+05 0.OOOE+00 9.510E+04 0.000E+00 2.840E+04 TC-99M 6.190E-21 1.210E-20 0.OOOE+00 1.760E-19 6.160E-21 6.910E-18 0.000E+00 2.010E-19 TC-101 0.OOOE+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.OOOE+00 RU-103 1.550E+08 0.000E+00 0.000E+00 3.900E+08 0.000E+00 4.010E+09 0.000E+00 5.960E+07 RU-105 9.020E-28 0.OOOE+00 0.000E+00 7.930E-27 0.000E+00 5.890E-25 0.000E+00 3.270E-28 RU-106 4.440E+09 0.000E+00 0.000E+00 5.990E+09 0.000E+00 6.900E+10 0.000E+00 5.540E+08 AG-110M 8.390E+06 5.670E+06 0.000E+00 1.060E+07 0.000E+00 6.740E+08 0.000E+00 4.530E+06 TE-125M 5.690E+08 1.540E+08 1.600E+08 0.000E+00 0.OOOE+00 5.490E+08 0.000E+00 7.590E+07 TE-127 3.380E-10 9.120E-11 2.340E-10 9.630E-10 0.OOOE+00 1.320E-08 0.OOOE+00 7.260E-11 TE-127M 1.770E+09 4.780E+08 4.240E+08 5.060E+09 0.OOOE+00 1.440E+09 0.OOOE+00 2:110E+08 TE-129 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00 0.OOOE+00 0.000E+00 TE-129M 1.790E+09 5.OOOE+08 5.770E+08 5.260E+09 0.000E+00 2.180E+09 0.000E+00 2.780E+08 TE-131 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 TE-131M 7.OOOE+02 2.420E+02 4.980E+02 2.340E+03 0.000E+00 9.820E+03 0.000E+00 2.580E+02 TE-132 2.120E+06 9.380E+05 1.370E+06 8.710E+06 0.000E+00 9.450E+06 0.OOOE+00 1.130E+06 1-130 3.030E-06 6.130E-06 6.750E-04 9.160E-06 0.000E+00 2.870E-06 0.000E+00 3.160E-06 Appendix I Ri Child Cow Meat - Page 2 of 3

0 January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX I Ri Child Dose Factors for use in the Gaseous Dose Calculations Agegroup:

CHILD Pathway:

Grs/Cow/Meat (CMEAT)

Units:

m 2.mrem/yr / jxCi/sec; C/3 mrem/yr /tim3(H-3).

Nuclide Bone Liver Thyroid Kidney,,

Lung Gilli'.

Skin

'Tojai.Bodqy 1-131 11650E+07 1.660E+07 5.500E+09 2.730E+07 0.OOOE+00 1.480E+06 0.OOOE+00 9.460E+06 1-132 1.020E-58 1.880E-58, 8.730E-57 2.880E-58 0.OOOE+00 2.210E-58 0.OOOE+00 8.650E-59 1-133 5.670E-01 7.020E-01 1.300E+02 1.170E+00 0.OOOE+00 2.830E-01 0.OOOE+00 2.660E-01 1-134 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1-135 6.510E-17 1.170E-16 1.040E-14 1.800E-16 0.OOOE+00 8.930E-17 0.OOOE+00 5.550E-17 CS-134 9.220E+08 1.510E+09 0.OOOE+00 4.690E+08 1.680E+08 8.160E+06 0.OOOE+00 3.190E+08 CS-136 1.620E+07 4.460E+07 0.OOOE+00 2.370E+07 3.540E+06 1.570E+06 0.000E+00 2.880E+07 CS-137 1.330E+09 1.280E+09 0.000E+00 4.160E+08 1.500E+08 7.990E+06 0.OOOE+00 1.880E+08 CS-138 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 BA-139 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 BA-140 4.380E+07 3.840E+04 0.OOOE+00.

1.250E+04 2.290E+04 2.220E+07 0.OOOE+00 2.560E+06 BA-141 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 BA-142 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00

  • .OOOE+00 LA-140 5.590E-02 1.950E-02 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.440E+02 0.OOOE+00 6.580E-03 LA-142 5.300E-92 1.690E-92 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.350E-87 0.OOOE+00 5.290E-93 CE-141 2.220E+04 1.11OE+04 0.OOOE+00 4.850E+03 0.OOOE+00 1.380E+07 0.OOOE+00 1.640E+03 CE-143 3.170E-02 1.720E+01 0.OOOE+00 7.210E-03, 0.OOOE+00 2.520E+02 0.OOOE+00 2.490E-03 CE-144 2.320E+06 7.260E+05 0.OOOE+00 4.020E+05 0.OOOE+00 1.890E+08 0.OOOE+00 1.240E+05 PR-143 3.340E+04 1.000E+04 0.OOOE+00 5.430E+03 0.OOOE+00 3.600E+07 0.000E+00 1.660E+03 PR-144 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 ND-147 1.170E+04 9.470E+03 0.OOOE+00 5.190E+03 0.OOOE+00 1.500E+07 0.OOOE+00 7.330E+02 W-187 3.210E-02 1.900E-02 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.670E400 0.OOOE+00 8.530E-03 NP-239 4.260E-01 3.060E-02 0.OOOE+00 8.850E-02 0.OOOE+00 2.260E+03 0.OOOE+00 2.150E-02 Appendix I Ri Child Cow Meat - Page 3 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX I Ri Child Dose Factors for use in the Gaseous Dose Calculations 2

Agegroup:

CHILD Pathway:

Vegetation (VEG)

Units:"

m mrem/yr /

-Ci/sec; mrem/ycr /.tCi/m 3 (--3)

Nuclide Bon'e Liver Thyroid Kidney Lung GilIL.

Skin

-TotaioBody H-3 0.OOOE+00 4.010E+03 4.010E+03 4.010E+03 4.010E+03 4.010E+03 0.OOOE+00 4.010E+03 C-14 8.890E+08 1.780E+08 1.780E+08 1.780E+08 1.780E+08 1.780E+08 0.OOOE+00 1.780E+08 NA-24 3.730E+05 3.730E+05 3.730E+05 3.730E+05 3.730E+05 3.730E+05 0.OOOE+00 3.730E+05 P-32 3.370E+09 1.580E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 9.310E+07 0.OOOE+00 1.300E+08 CR-51 0.OOOE+00 0.OOOE+00 6.500E+04 1.780E+04 1.190E+05 6.210E+06 0.000E+00 1.170E+05 MN-54 0.OOOE+00 6.650E+08 0.OOOE+00 1.860E+08 0.OOOE+00 5.580E+08 0.OOOE+00 1.770E+08 MN-56 0.OOOE+00 1.860E+01 0.OOOE+00 2.250E+01 0.000E+00 2.700E+03 0.OOOE+00 4.200E+00 FE-55 8.010E+08 4.250E+08 0.OOOE+00 0.OOOE+00 2.400E+08 7.870E+07 0.OOOE+00 1.320E+08 FE-59 3.980E+08 6.430E+08 0.OOOE+00 0.OOOE+00 1.860E+08 6.700E+08 0.OOOE+00 3.200E+08 CO-58 0.OOOE+00 6.440E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.760E+08 0.OOOE+00 1.970E+08 CO-60 0.OOOE+00 3.780E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.100E+09 0.OOOE+00 1.120E+09 NI-63 3.950E+10 2.11OE+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.420E+08 0.OOOE+00 1.340E+09 NI-65 1.050E+02 9.890E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.210E+03 0.OOOE+00 5.770E+00 CU-64 0.OOOE+00 1.100E+04 0.000E+00 2.660E+04 0.600E+00 5.160E+05 0.OOOE+00 6.640E+03 ZN-65 8.130E+08 2.160E+09 0.OOOE+00 1.360E+09 O.OOOE+00 3.800E+08 0.OOOE+00 1.350E+09 ZN-69 9.490E-06 1.370E-05 0.OOOE+00 8.320E-06 0.OOOE+00 8.640E-04' 0.OOOE+00 1.270E-06 BR-83 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.370E+00 BR-84 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 0.OOOE+00 0.000E+00 3.820E-1 1 BR-85 0.000E+00 0.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RB-86 0.OOOE+00 4.520E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.910E+07 0.OOOE+00 2.780E+08 RB-88 0.OOOE+00 4.380E-22 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.150E-23 0.OOOE+00 3.040E-22 RB-89 0.OOOE+00 4.6 1OE-26 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.020E-28 0.OOOE+00.

4.090E-26 SR-89 3.600E+10 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.390E+09 0.OOOE+00 1.030E+09 SR-90 1.240E+12 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.670E+10 0.000E+00 3.150E+11 SR-91 5.240E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.160E+06 0.OOOE+00 1.980E+04 L

Appendix I Ri Child Vegetation - Page 1 of 3

e Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM) 0 January, 2010 Revision 52 APPENDIX I R_ Child Dose Factors for use in the Gaseous Dose Calculations

'Agiegroup:

CHILD Pathway::

Vegetation (VEG)

Units:

m2,mrem/yr / gCi/sec;

___i__mrem/yr

/(

-3)

Nuclide.

Bone Liver Thyroid Kidney Lung Gilli' Skin Total Body SR-92 7.280E+02 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 1.380E+04 0.OOOE+00 2.920E+01 Y-90 2.310E+04 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 6.570E+07 0.OOOE+00 6.180E+02 Y-91 1.860E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.480E+09 0.OOOE+00 4.990E+05 Y-91M 8.910E-09 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.740E-05 0.OOOE+00 3.240E-10 Y-92 1.580E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.580E+04 0.OOOE+00 4.530E-02 Y-93 2.930E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.370E+06 0.000E+00 8.040E+00 ZR-95 3.860E+06 8.480E+05 0.OOOE+00 1.210E+06 0.OOOE+00 8.850E+08 0.OOOE+00 7.550E+05 ZR-97 5.700E+02 8.240E+01 0.OOOE+00 1.180E+02 0.OOOE+00 1.250E+07 0.OOOE+00 4.860E+01 NB-95 4.11OE+05 1.600E+05 0.OOOE+00 1.500E+05 O.OOOE+00 2.960E+08 0.OOOE+00 1.140E+05 MO-99 0.OOOE+00 7.710E+06 0.OOOE+00 1.650E+07 0.OOOE+00 6.380E+06 0.OOOE+00 1.910E+06 TC-99M 4.710E+00 9.230E+00 0.OOOE+00 1.340E+02 4.690E+00 5.260E+03 0.OOOE+00 1.530E+02 TC-101 1.410E-30 1.470E-30 0.OOOE+00 2.51 OE-29 7.780E-31 4.680E-30 0.OOOE+00 1.870E-29 RU-103 1.530E+07 0.OOOE+00 0.OOOE+00 3.860E+07 0.OOOE+00 3.970E+08 0.OOOE+00 5.900E+06 RU-105 9.160E+01 0.OOOE+00 0.OOOE+00 8.050E+02 0.000E+00 5.980E+04 0.OOOE+00 3.320E+01 RU-106 7.450E+08 0.OOOE+00 0.OOOE+00 1.010E+09 0.OOOE+00 1.160E+10 0.OOOE+00 9.300E+07 AG-110M 3.210E+07 2.170E+07 0.OOOE+00 4.040E+07.

0.OOOE+00 2.580E+09 0.000E+00 1.730E+07 TE-125M 3.510E+08 9.500E+07 9.840E+07 0.OOOE+00 0.OOOE+00 3.380E+08 0.000E+00 4.670E+07 TE-127 9.850E+03 2.650E+03 6.810E+03 2.800E+04 0.000E+00 3.850E+05 0.OOOE+00 2.11OE+03 TE-127M 1.320E+09.

3.560E+08 3.160E+08 3.770E+09 0.OOOE+00 1.070E+09 0.OOOE+00 1.570E+08 TE-129 1.320E-03 3.690E-04 9.430E-04 3.870E-03 0.000E+00 8.230E-02 0.OOOE+00 3.140E-04 TE-129M 8.410E+08 2.350E+08 2.710E+08 2.470E+09 0.OOOE+00 1.030E+09 0.OOOE+00 1.310E+08 TE-131 2.570E-15 7.830E-16 1.960E-15 7.770E-15 0.OOOE+00 1.350E-14 0.OOOE+00 7.640E-16 TE-131M 1.540E+06 5.330E+05

1. 1OOE+06 5.160E+06 0.000E+00 2.160E+07 0.OOOE+00 5.680E+05 TE-132 7.000E+06 3.100E+06 4.5 1OE+06 2.880E+07 0.OOOE+00 3.120E+07 O.OOOE+00 3.740E+06 1-130 6.160E+05 i.240E+06 1.370E+08 1.860E+06 0.OOOE+00 5.820E+05 0.OOOE+00 6.410E+05 Appendix I Ri Child Vegetation - Page 2 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX I R_ Child Dose Factors for use in the Gaseous Dose Calculations Agegroup:

CHILD Pathway:

Vegetation (VEG)

ý' ý-Units:

m.mrem/yr / tCi/sec;

mrem/yr

/(Ci/m 3 (H-3)

Nuclide Bone Liver Thyroid

-ý,Kidney.

Lung Gilli' K

Skin, Total Body 1-131 1.430E+08 1.440E+08 4.750E+10 2.360E+08 0.000E+00 1.280E+07 0.000E+00 8.170E+07 1-132 9.220E+-01 1.690E+02 7.860E+03 2.590E+02 0.000E+00 1.990E+02 0.000E+00 7.790E+01 1-133 3.530E+06 4.370E+06 8.1 10E+08 7.280E+06 O.000E+00 1.760E+06 0.000E+00 1.650E+06 1-134 1.550E-04 2.880E-04 6.620E-03 4.400E-04 0.000E+00 1.910E-04 0.OOOE+00 1.320E-04 1-135 6.260E+04 1.130E+05 9.970E+06 1.730E+05 0.000E+00 8.580E+04 0.000E+00 5.330E+04 CS-134 1.600E+10 2.630E+10 0.000E+00 8.150E+09 2.930E+09 1.420E+08 0.000E+00 5.550E+09 CS-136 8.240E+07 2.270E+08 0.000E+00 1.210E+08 1.800E+07 7.960E+06 0.000E+00 1.470E+08 CS-137 2.390E+10 2.290E+10 0.000E+00 7.460E+09 2.680E+09 1.430E+08 0.000E+00 3.380E+09 CS-138 6.570E-11 9.130E-11 0.000E+00 6.430E-I 1 6.920E-12 4.210E-11 0.000E+00 5.790E-11 BA-139 4.950E-02 2.640E-05 0.000E+00 2.3 10E-05 1.560E-05 2.860E+00 0.000E+00 1.440E-03 BA-140 2.770E+08 2.420E+05 0.OOOE+00 7.890E+04 1.450E+05 1.400E+08 0.000E+00 1.610E+07 BA-141 1.990E-21 1.11OE-24 0.000E+00 9.620E-25 6.530E-24 1.130E-21 0.000E+00 6.460E-23 BA-142 9.930E-39 7.150E-42 0.000E-00 5.780E-42 4.200E-42 1.300E-40 0.000E+00 5.540E-40 LA-140 3.250E+03 1.130E+03 0.000E+00 0.000E+00 0.000E+00 3.160E+07 0.000E+00 3.820E+02 LA-142 3.360E-04 1.070E-04 0.000E+00 0.OOOE+00 0.OOOE+00 2.120E+01 0.000E+00 3.350E-05 CE-141 6.560E+05 3.270E+05 0.OOOE+00 1.430E+05 0.OOOE+00 4.080E+08 0.OOOE+00 4.860E+04 CE-143 1.720E+03 9.310E+05 0.000E+00 3.910E+02 0.OOOE+00 1.360E+07 0.000E+00 1.350E+02 CE-144 1.270E+08 3.980E+07 0.OOOE+00 2.210E+07 0.000E+00 1.040E+10 0.000E+00 6.780E+06 PR-143 1.460E+05 4.370E+04 0.OOOEI+00 2.370E+04 0.000E+00 1.570E+08 0.000E+00 7.230E+03 PR-144 5.380E-26 1.660E-26 0.OOOE+00 8.800E-27 0.OOOE+00 3.580E-23 0.000E+00 2.710E-27 ND-147 7.150E+04 5.790E+04 0.OOOE+00 3.180E+04 0.OOOE+00 9.170E+07 0.OOOE+00 4.480E+03 W-187 6.430E+04 3.810E+04 0.000E+00 0.OOOE+00 0.000E+00 5.350E+06 0.000E+00 1.710E+04 NP-239 2.560E+03 1.840E+02 0.000E+00 5 310E+02 0.OOOE+00 1.360E+07 0.OOOE+00 1.290E+02 Appendix I Ri Child Vegetation - Page 3 of 3

0 January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

Ri Child Dose APPENDIX I Factors for use in the Gaseous Dose Calculations Agegroup:

CHILD Pathway:

Inhalation (INHL)

Units:.P mrem/yr / ptCi/m3 Nuclide

!Bfnegi Liver Thyroid

,*Kidney

Lung, Gilli'

!ASidn""{

TotalBody H-3 0.OOOE+00 1.120E+03 1.120E+03 1.120E+03 1.120E+03 1.120E+03 0.OOOE+00 1.120E+03 C-14 3.590E+04 6.730E+03 6.730E+03 6.730E+03 6.730E+03 6.730E+03 0.OOOE+00 6'730E+03 NA-24 1.610E+04 1.610E+04 1.610E+04 1.610E+04 1.610E+04 1.610E+04 0.OOOE+00 1.610E+04 P-32 2.600E+06 1.140E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.220E+04 0.OOOE+00 9.880E+04 CR-51 0.OOOE+00 0.OOOE+00 8.550E+01 2.430E+01 1.700E+04 1.080E+03 0.OOOE+00 1.540E+02.

MN-54 0.OOOE+00 4.290E+04 0.OOOE+00 1.000E+04 1.580E+06 2.290E+04 0.OOOE+00 9.510E+03 MN-56 0.000E+00 1.660E+00 0.OOOE+00 1.670E+00 1.310E+04 1.230E+05 0.OOOE+00 3.120E-01 FE-55 4.740E+04 2.520E+04 0.OOOE+00 0.OOOE+00 1.11OE+05 2.870E+03 0.OOOE+00, 7.770E+03 FE-59 2.070E+04 3.340E+04 0.OOOE+00 0.OOOE+00 1.270E+06 7.070E+04 0.OOOE+00 1.670E+04 CO-58 0.OOOE+00 1.770E+03 0.OOOE+00 0.OOOE+00 1.11OE+06 3.440E+04 0.OOOE+00 3.160E+03 CO-60 0.OOOE+00 1.310E+04 0.OOOE+00 0.OOOE+00 7.070E+06 9.620E+04 0.000E+00 2.260E+04 NI-63 8.210E+05 4.620E+04 0.OOOE+00 0.OOOE+00 2.750E+05 6.330E+03 0.OOOE+00 2.800E+04 NI-65 2.990E+00 2.960E-01 0.OOOE+00 0.OOOE+00 8.180E+03 8.400E+04 0.OOOE+00

'1.640E-01 CU-64 0.000E+00 1.990E+00 0.OOOE+00 6.030E+00 9.580E+03 3.670E+04 0.OOOE+00 1.070E+00 ZN-65 4.260E+04 1.130E+05 0.OOOE+00 7.140E+04 9.950E+05 1.630E+04 0.OOOE+00 7.030E+04 ZN-69 6.700E-02 9.660E-02 0.OOOE+00 5.850E-02 1.420E+03 1.020E+04 0.OOOE+00 8.920E-03 BR-83 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.740E+02 BR-84 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 5.480E+02 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.530E+01 RB-86 0.006E+00 1.980E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 7.990E+03 0.000E+00 1.140E+05 RB-88 0.OOOE+00 5.620E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.720E+01 0.OOOE-+00 3.660E+02 RB-89 0.000E+00 3.450E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.890E+00 0.OOOE+00 2.900E+02 SR-89 5.990E+05 0.000E+00 0.OOOE+00 0.OOOE+00 2.160E+06 1.670E+05 0.OOOE+00 1.720E+04 SR-90 1.O1OE+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.480E+07 3.430E+05

,O.OOOE+00 6.440E+06 SR-91 1.210E+02 0.OOOE+00

'0.OOOE-00 0.OOOE+00 5.330E+04 1.740E+05 0.OOOE+00 4.590E+00 Appendix I Ri Child Inhalation - Page I of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX I R, Child Dose Factors for use in the Gaseous Dose Calculations Agegroup:

CHILD Pathway; Inhalation (INHL)

Units:

mrem/yr / ýCi/m3

'Nuclide Bone.-

Liver,-

Thyroid Kidney

]

Lng.

Gili, Skin, Total Body SR-92 1.310E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.400E+04 2.420E+05 0.OOOE+00 5.250E-01 Y-90 4.1101E+03 0.OOOE+00 0.000E+00 0.OOOE+00 2.620E+05 2.680E+05 0.OOOE+00 1.11OE+02 Y-91 9.140E+05 0.000E+00 0.OOOE+00 0.OOOE+00 2.630E+06 1.840E+05 0.OOOE+00 2.440E+04 Y-91M 5.070E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.810E+03 1.720E+03 0.OOOE+00 1.840E-02 Y-92 2.030E+01 0.OOOE+00 0.OOOE+00 0:OOOE+00 2.390E+04 2.390E+05 0.OOOE+00 5.810E-01 Y-93 1.860E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 7.440E+04 3.880E+05 0.000E+00 5.11OE+00 ZR-95 1.900E+05 4.180E+04 0.OOOE+00 5.960E+04 2.230E+06 6.11OE+04-0.OOOE+00 3.700E+04 ZR-97 1.880E+02 2.720E+01 0.000E+00 3.880E+01 1.130E+05 3.510E+05 0.000E+00 1.600E+01 NB-95 2.350E+04 9.180E+03 0.000E+00 8.620E+03 6.140E+05 3.700E+04 O.OOOE+00 6.550E+03 MO-99 0.OOOE+00 1.720E+02 0.OOOE+00

.3.920E+02 1.350E+05 1.270E+05 0.OOOE+00 4.260E+01 TC-99M i.780E-03 3.480E-03 0.000E+00 5.070E-02 9.510E+02 4.810E+03 0.OOOE+00 5.770E-02 TC-101 8.100E-05 8.510E-05 0.000E+00

  • 1.450E-03 5.850E+02 1.630E+01 0.OOOE+00 1.080E-03 RU-103 2.790E+03 0.OOOE+00 0.OOOE+00 7.030E+03 6.620E+05 4.480E+04 0.OOOE+00 1.070E+03 RU-105 1.530E+00 0.OOOE+00 0.OOOE+00 1.340E+00 1.590E+04 9.950E+04 0.OOOE+00 5.550E-01 RU-106 1.360E+05 O.OOOE+00 0.OOOE+00 1.840E+05 1.430E+07 4.290E+05 0.OOOE+00 1.690E+04 AG-110M 1.690Eq-04 1.140E+04 0.OOOE+00 2.120E+04 5.480E+06 1.000E+05 0.OOOE+00 9.140E+03 TE-125M 6.730E+03 2.330E+03 1.920E+03 0.OOOE+00 4.770E+05 3.380E+04 0.OOOE+00 9.140E+02 TE-127 2.770E+00 9.510E-01 1.960E+00 7.070E+00 1.000E+04 5.620E+04 0.OOOE+00 6.100E-01 TE-127M 2.490E+04 8.550E+03 6.070E+03 6.360E+04 1.480E+06 7.140E+04 0.OOOE+00 3.020E+03 TE-129 9.770E-02 3.500E-02 7.140E-02 2.570E-01 2.930E+03 2.550E+04 0.OOOE+00 2.380E-02 TE-129M 1.920E+04 6.840E+03 6.330E+03 5.030E+04 1.760E+06 1.820E+05 0.OOOE+00 3.040E+03 TE-131 2.170E-02 8.440E-03 1.700E-02 5.880E-02 2.050E+03 1.330E+03 0.OOOE+00 6.590E-03 TE-131M 1.340E+02 5.920E+01 9.770E+01 4.OOOE+02 2.060E+05 3.080E+05 0.000E+00 5.070E+01 TE-132 4.810E+02 2.720E+02 3.170E+02 1.770E+03-3.770E+05 1.380E+05 0.000E+00 2.630E+02 11-130 8.180E+03 1.640E+04 1.850E+06 2.450E+04 0.OOOE+00 5.11OE+03 0.OOOE+00 8.440E+03 Appendix I Ri Child Inhalation - Page 2 of 3

January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX I Ri Child Dose Factors for use in the Gaseous Dose Calculations

',Agegroup:

CHILD Pathway:

Inhalation (INI-L)

Units:

mrem/yr / pCi/m 3 Nuclide Bone; Ie.

Liver Thyroid K idney fLun Gilli 1 Skin,,

Totail'd y 1-131 4.810E+04 4.810E-+04 1.620E+07 7.880E+04 0.000E+00 2.840E+03 0.OOOE+00 2.730E+04 1-132 2.120E+03 4.070E+03 1.940E+05 6.250E+03 0.000E+00 3.200E+03 0.OOOE+00 1.880E+03 1-133 1.660E+04 2.030E+04 3.850E+06 3.380E+04 0.OOOE+00 5.480E+03 0.OOOE+00 7.700E+03 1-134 1.170E+03 2.160E+03 5.070E+04 3.300E+03 0.OOOE+00 9.550E+02 0.OOOE+00 9.950E+02 1-135 4.920E+03 8.730E+03 7.920E+05 1.340E+04 0.OOOE+00 4.440E+03 0.OOOE+00 4.140E+03 CS-134 6.510E+05 1.01OE+06 0.OOOE+00 3.300E+05 1.210E+05 3.850E+03 0.OOOE+00 2.250E+05 CS-136 6.510E+04 1.710E+05 0.OOOE+00 9.550E+04 1.450E+04 4.180E+03 0.OOOE+00 1:160E+05 CS-137 9.060E+05 8.250E+05 0.OOOE+00 2.820E+05 1.040E+05 3.620E+03 0.OOOE+00 1.280E+05 CS-138 6.330E+02 8.400E+02 0.OOOE+00 6.220E+02 6.810E+01 2.700E+02 0.OOOE+00 5.550E+02 BA-139 1.840E+00 9.840E-04 0.OOOE+00 8.620E-04 5.770E+03 5.770E+04 0.OOOE+00 5.360E-02 BA-140 7.400E+04 6.480E+01 0.OOOE+00 2.11 OE+01 1.740E+06 1.020E+05 0.OOOE+00 4.330E+03 BA-141 1.960E-01 1.090E-04 0.OOOE+00 9.470E-05 2.920E+03 2.750E+02 0.OOOE+00 6.360E-03 BA-142 5.OOOE-02 3.600E-05 0.OOOE+00 2.910E-05 1.640E+03 2.740E+00 0.OOOE+00 2.790E-03 LA-140 6.440E+02 2.250E+02 0.OOOE+00 O.OOOE+00 1.830E+05 2.260E+05 0.OOOE+00 7.550E+01 LA-142 1.300E+00 4.11OE-01 0.OOOE+00 0.OOOE+00 8.700E+03 7.580E+04 0.000E+00 1.290E-01 CE-141 3.920E+04 1.950E+04 0.OOOE+00 8.550E+03 5.440E+05 5.660E+04 0.OOOE+00 2.900E+03 CE-143 3.660E+02 1.990E+02 0.OOOE+00 8.360E+01 1.150E+05 1.270E+05 0.OOOE+00 2.870E+01 CE-144 6.770E+06 2.120E+06 0.OOOE+00 1.170E+06 1.200E+07 3.880E+05 0.OOOE+00 3.610E+05 PR-143 1.850E+04 5.550E+03.

0.OOOE+00 3.OOOE+03 4.330E+05 9.730E+04 0.OOOE+00 9.140E+02 PR-144 5.960E-02 1.850E-02 0.OOOE+00 9.770E-03 1.570E+03 1.970E+02 0.OOOE+00 3.OOOE-03 ND-147 1.080E+04 8.730E+03 O.OOOE+00 4.810E+03 3.280E+05 8.210E+04 0.OOOE+00 6.810E+02 W-187 1.630E+01 9.660E+00 0.OOOE+00 0.OOOE+00 4.11OE+04 9.100E+04 0.OOOE+00 4.330E+00 NP-239 4:660E+02 3.340E+01 0.OOOE+00 9.730E+01 5.810E+04 6.400E+04 0.OOOE+00 2.350E+01 Appendix I Ri Child Inhalation - Page 3 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX I R1 Child Dose Factors for use in the Gaseous Dose Calculations Agegroup:.

CHILD Pathway:

Ground Plane Deposition (GPD)

Units:

m2.mrem/yr / pCi/sec Nuclide',-.,Bone Liveir Thyrod" Kdney LUng Gilli Skin T6talBody, H-3 0.000E+00 0.000E+00" 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 C-14 0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 0.000E+00 0.OOOE+00 0.000E+00 0.000E+00 NA-24 1.190E+07 1.190E+07 1.190E+07 1.190E+07 1.190E+07 1.190E+07 1.390E+07 1.190E+07 P-32 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 CR-5 1 4.660E+06 4.660E+06 4.660E+06 4.660E+06 4.660E+06 4.660E+06 5.510E+06 4.660E+06 MN-54 1.390E+09 1.390E+09 1.390E+09 1.390E+09 1.390E+09 1.390E+09 1.630E+09 1.390E+09 MN-56 9.020E+05 9.020E+05 9.020E+05 9.020E+05 9.020E+05 9.020E+05 1.070E+06 9.020E+05 FE-55 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 FE-59 2.730E+08 2.730E+08 2.730E+08 2.730E+08 2.730E+08 2.730E+08 3.210E+08 2.730E+08 CO-58 3.790E+08 3.790E+08 3.790E+08 3.790E+08 3.790E+08 3.790E+08 4.440E+08 3.790E+08 CO-60 2.150E+10 2.150E+10 2.150E+10 2.150E+10 2.150E+10 2.150E+10 2.530E+10 2.150E+10 NI-63 0.000E+00 0.OOOE+00 0.000E+00 0.000E+00 0.000E+00 0.OOOE+00 0.000E+00 0.000E+00 NI-65 2.970E+05 2.970E+05 2.970E+05 2.970E+05 2.970E+05 2.970E+05 3.450E+05 2.970Et05 CU-64 6.070E+05 6.070E+05 6.070E+05 6.070E+05 6.070E+05 6.070E+05 6.880E+05 6.070E+05 ZN-65 7.470E+08 7.470E+08 7.470E+08 7.470E+08 7.470E+08 7.470E+08 8.590E+08 7.470E+08 ZN-69 0.OOOE+00 0.000E+00 0.000E+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 0.OOOE+00 BR-83 4.870E+03 4.870E+03 4.870E+03 4.870E+03 4.870E+03 4.870E+03 7.080E+03 4.870E+03 BR-84 2.030E+05 2.030E+05 2.030E+05 2.030E+05 2.030E+05 2.030E+05 2.360E+05 2.030E+05 BR-85 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00 0.OOOE+00 RB-86 8.990E+06 8.990E+06 8.990E+06 8.990E+06 8.990E+06 8.990E+06 1.030E+07 8.990E+06 RB-88 3.310E+04 3.310E+04 3.310E+04 3.310E+04 3.310E+04 3.310E+04 3.780E+04 3.310E-l+04 RB-89 1.230E+05 1.230E+05 1.230E+05 1.230E+05 1.230E+05 1.230E+05 1.480E+05 1.230E+05 SR-89 2.160E+04 2.160E+04 2.160E+04 2.160E+04 2.160E+04 2.160E+04 2.510E+04 2.160E+04 SR-90 0.000E+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 SR-91 2.150E+06 2.150E-+06.

2.150E+06 2.150E+06 2.150E+06 2.150E+06 2.510E+06 2.150E+06

)

Appendix I Ri Child Ground Plane Deposition - Page 1 of 3 0

January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX I R. Child Dose Factors for use in the Gaseous Dose Calculations

)

Agegroup:

CHILD Pathway:

Ground Plane Deposition (GPD)

Units:,

m 2mrem/yr / PCi/sec Nuclide Bone Liver..'

Thyroid Kidney.

Lung Skin TOtal Body SR-92 7.770E+05 7.770E+05 7.770E+05 7.770E+05 7.770E+05 7.770E+05 8.630E+05 7.770E+05

,Y-90 4.490E+03 4.490E+03 4.490E+03 4.490E+03 4.490E+03 4.490E+03 5.310E+03 4.490E+03 Y-91 1.070E+06 1.070E+06 1.070E+06 1.070E+06 1.070E+06 1.070E+06 1.210E+06 1.070E+06 Y-91M 1.000E+05 1.000E+05 1.000E+05 1OOOE+05 1.000E+05 1.000E+05 1.160E+05 1.000E+05 Y-92 1.800E+05 1.800E+05 1.800E+05 1.800E+05 1.800E+05 1.800E+05 2.140E+05 1.800E+05 Y-93 1.830E+05 1.830E+05 1.830E+05 1.830E+05 1.830E+05 1.830E+05 2.510E+05 1.830E+05 ZR-95 2.450E+08 2.450E+08 2.450E+08 2.450E+08 2.450E+08 2.450E+08 2.840E+08 2.450E+08 ZR-97 2.960E+06 2.960E+06 2.960E+06 2.960E+06 2.960E+06 2.960E+06 3.440E+06 2.960E+06 NB-95 1.370E+08 1.370E+08 1.370E+08 1.370E+08 1.370E+08 1.370E+08 1.610E+08 1.370E+08 MO-99 3.990E+06 3.990E+06 3.990E+06 3.990E+06 3.990E+06 3.990E+06 4.630E+06 3.990E+06 TC-99M 1.840E+05 1.840E+05 1.840E+05 1.840E+05 1.840E+05 1.840E+05 2.1 10E+05 1.840E+05 TC-101 2.040E+04 2.040E+04 2.040E+04 2.040E+04 2.040E+04 2.040E+04 2.260E+04 2.040E+04 RU-103 1.080E+08 1.080E+08 1.080E+08 1.080E+08 1.080E+08 1.080E+08 1.260E+08 1.080E+08 RU-105 6.360E+05 6.360E+05 6.360E+05 6.360E+05:

6.360E+05 6.360E+05 7.210E+05 6.360E+05 RU-106 4.220E+08 4.220E+08 4.220E+08 4.220E+08 4.220E+08 4.220E+08 5.070E+08 4.220E+08 AG-110M 3.440E+09 3.440E+09 3.440E+09 3.440E+09 3.440E+09 3.440E+09 4.010E+09 3.440E+09 TE-125M 1.550E+06 1.550E+06 1.550E+06 1.550E+06 1.550E+06 1.550E+06 2.130E+06 1.550E+06 TE-127 2.980E+03 2.980E+03 2.980E+03 2.980E+03 2.980E+03 2.980E+03 3.280E+03 2.980E+03 TE-127M 9.160E+04 9.160E+04 9.160E+/-04 9.160E+04 9.160E+04 9.160E+04 1.080E+05

.9.160E+04 TE-129 2.620E+04 2.620E+04 2.620E+04 2.620E+04 2.620E+04 2.620E+04 3.100E+04 2.620E+04 TE-129M 1.980E+07-1.980E+07 1.980E+07 1.980E+07 1.980E+07 1.980E+07 2.3 10E+07 1.980E+07 TE-131 2.920E+04 2.920E+04 2.920E+04 2.920E+04 2.920E+04 2.920E+04 3.450E+07 2.920E+04 TE-131M 8.030E+06 8.030E+06 8.030E+06 8.030E+06 8.030E+06 8.030E+06 9.460E+06 8.030E+06 TE-132 4.230E+06 4.230E+06 4.230E+06 4.230E+06.

4.230E+06 4.230E+06 4.980E+06 4.230E+06 11-130 5.510E+06 5.5 1OE+06 5.5 1OE+06 5.510E+06 5.5 1OE+06 5.5 1OE+06 6.690E+06 5.510E+06 Appendix I Ri Child Ground Plane Deposition - Page 2 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX I R, Child Dose Factors for use in the Gaseous Dose Calculations Agegroup:

CHILD Pathway:

Ground Plane Deposition (GPD)

Units:

m2 mrem/yr / JLCi/sec Nuclide Bone Liver Thiyroid Kidney Lung.

-Gilli:

'Skin

Total Body 1-131 1.720E+07 1.720E+07 1.720E+07 1.720E+07 1.720E+07 1.720E+07 2.090E+07 1.720E+07 1-132 1.250E+06 1.250E+06 1.250E+06 1.250E+06 1.250E+06 1.250E+06 1.470E+06 1.250E+06 1-133 2.450E+06 2.450E+06 2.450E+06 2.450E+06 2.450E+06 2.450E+06 2.980E+06 2.450E+06 1-134 4.470E+05 4.470E+05 4.470E+05 4.470E+05 4.470E+05 4.470E+05 5.300E+05 4.470E+05 1-135 2.530E+06 2.530E+06 2.530E+06 2.530E+06 2.530E+06 2.530E+06 2.950E+06 2.530E+06 CS-134 6.860E+09 6.860E+09 6.860E+09 6.860E+09 6.860E+09 6.860E+09 8.OOOE+09 6.860E+09 CS-136 1.510E+08 1.510E+08 1.510E+08 1.510E+08 1.510E+08 1.510E+08 1.710E+08 1.510E+08 CS-137 1.030E+10 1.030E+10 1.030E+10 1.030E+10 1.030E+10 1.200E+10 1.030E+10 CS-138 3.590E+05 3.590E+05 3.590E+05 3.590E+05 3.590E+05 3.590E+05 4.100E+05 3.590E+05 BA-139 1.060E+05 1.060E+05 1.060E+05 1.060E+05 1.060E+05 1.060E+05 1.190E+05 1.060E+05 BA-140 2.050E+07 2.050E+07 2.050E+07 2.050E+07 2.050E+07 2.050E+07 2.350E+07 2.050E+07 BA-141 4.170E+04 4.170E+04 4.170E+04 4.170E+04 4.170E+04 4.170E+04 4.750E+04 4.170E+04 BA-142 4.490E+04 4.490E+04 4.490E+04 4.490E+04 4.490E+04 4.490E+04 5.1 10E+04 4.490E+04 LA-140 1.920E+07 1.920E+07 1.920E+07 1.920E+07 1.920E+07 1.920E+07 2.180E+07 1.920E+07 LA-142 7.600E+05 7.600E+05 7.600E+05 7.600E+05 7.600E+05 7.600E+05 9.120E+05 7.600E+05 CE-141 1.370E+07 1.370E+07 1.370E+07 1.370E+07 1.370E+07 1.370E+07 1.540E+07 1.370E+07 CE-143 2.310E+06 2.310E+06 2.310E+06 2.310E+06 2.310E+06 2.310E+06 2.630E+06 2.310E+06 CE-144 6.950E+07 6.950E+07 6.950E+07 6.950E+07 6.950E+07 6.950E+07 8.040E+07 6.950E+07 PR-143 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00' PR-144 1.830E+03 1.830E+03 1.830E+03 1.830E+03 1.830E+03 1.830E+03 2.11OE+03 1.830E+03 ND-147 8.390E+06 8.390E+06 8.390E+06 8.390E+06 8.390E+06 8.390E+06 1.010E+07 8.390E+06 W-187 2.350E+06 2.350E+06 2.350E+06 2.350E+06 2.350E+06 2.350E+06 2.730E+06 2.350E+06 NP-239 1.710E+06 1.710E+06 1.710E+06 1.710E+06 1.710E+06 1.710E+06 1.980E+06 1.710E+06 Appendix I Ri Child Ground Plane Deposition 7 Page 3 of 3 0

January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX J Ri Infant Dose Factors for use in the Gaseous Dose Calculations

,Agegroup:

INFANT Pathway:

Grs/Cow/Milk (CMILK)

Units:'

m2.mrem/yr / *tCi/sec; mrem/yr /tCi/m 3 (H--3)

Nuiclide&

Bone: -

Livei*

Thyroid

Kidney, Liihg:
:Gilli Skin Total Body H-3 0.000E+00 2.380E+03 2.380E+03 2.380E+03 2.380E+03 2.380E+03 0.OOOE+00 2.380E+03 C-14 2.340E+09 5.OOOE+08 5.OOOE+08 5.OOOE+08 5.OOOE+08 5.OOOE+08 0.OOOE+00 5.OOOE+08 NA-24 1.540E+07 1.540Et07 1.540E+07 1.540E+07 1.540E+07 1.540E+07 0.OOOE+00 1.540E+07 P-32 1.600E+1 1 9.430E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.J 7OE+09 0.OOOE+00 6.210E+09 CR-51 0.OOOE+00 0.OOOE+00 1.050E+05 2.300E+04 2.050E+05 4.700E+06 0.OOOE+00 1.610E+05 MN-54 O.OOOE+00 3.900E+07 0.OOOE+00 8.640E+06 0.000E+00 1.430E+07 0.000E+00 8.840E+06 MN 0.OOOE+00 3.100E-02 0.OOOE+00 2.660E-02 0.OOOE+00 2.810E+00 0.OOOE+00 5.340E-03 FE-55 1.350E+08 8.730E+07 0.OOOE+00 0.OOOE+00 4.270E+07 1.11OE+07 0.OOOE+00 2.330E+07 FE-59 2.240E+08 3.920E+08 0.OOOE+00 0.OOOE+00 1.160E+08 1.870E+08 0.OOOE+00 1.540E+08 CO-58 0.OOOE+00 2.420E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.040E+07 0.OOOE+00 6.050E+07 CO-60 0.OOOE+00 8.820E+07 0.OOOE+00 0.000E+00 0.OOOE+00 2.100E+08 0.OOOE+00 2.080E+08 NI-63 3.490E+10 2.160E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.070E+08 0.OOOE+00 1.210E+09 NI-65 3.510E+00 3.970E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.020E+01 0.OOOE+00 1.800E-01 CU-64 0.OOOE+00 1.850E+05 0.OOOE+00 3.140E+05 0.OOOE+00 3.810E+06 0.OOOE+00 8.590E+04 ZN-65 5.550E+09 1.900E+10 0.OOOE+00 9.230E+09 0.OOOE+00 1.610E+10 0.OOOE+00 8.780E+09 ZN-69 2.020E-11 3.630E-11 0.OOOE+00 1.510E-11 0.OOOE+00 2.960E-09 0.OOOE+00 2.700E-12 BR-83 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 9.340E-01 BR-84 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.260E-22 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RB-86 0.000E+00 2.230E+10 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.690E+08 0.OOOE+00 1.100E+10 RB-88 0.OOOE+00 1.880E-44 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.830E-44 0.OOOE+00 1.030E-44 RB-89 0.OOOE+00 3.290E-52 0.OOOE+00 O.OOOE+00 0.OOOE+00 1.120E-52 0.OOOE+00 2.260E-52 SR-89 1.260E+10 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.590E+08 0.OOOE+00 3.610E+08 SR-90 1.220E+1 1 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.520E+09 0.OOOE+00 3.100E+10 SR-91 2.720E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.220E+05 0.000E+00 9.830E+03 Appendix J Ri Infant Cow Milk - Page 1 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX J R1 Infant Dose Factors for use in the Gaseous Dose Calculations

/

Agegroup:,

INFANT Pathway:

Grs/Cow/Milk (CMILK)

Units:

m2-mrem/yr / tCi/sec;

_mrem/yr

/(HCi/m 3(11-3)

Nuclide" Bone.

Liver Thyroid Kidney

-Lun'g Gilli Skin Total.Body SR-92 4.640E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.OOOE+01 0.OOOE+00 1.720E-01 Y-90 6.810E+02 0.OOOE+00 0.600E+00 0.OOOE+00 0.OOOE+00 9.410E+05 0.OOOE+00 1.830E+04 Y-9L 7.330E+04 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.250E+06 0.OOOE+00 1.950E+03 Y-91M 5.670E-19 0.OOOE+00 0.000E+00 0.000E+00 0.OOOE+00 1.890E-15 0.000E+00 1.930E-20 Y-92 5.380E-04 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 1.030E+01 0.0OOE+00 1.510E-05 Y-93 2.160E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.700E+04 0.OOOE+00 5.870E-02 ZR-95 6:800E+03 1.660E+03 0.OOOE+00 1.790E+03 0.OOOE+00 8.260E+05 0.OOOE+00 1.180E+03 ZR-97 4.060E+00 6.970E-01 0.OOOE+00 7.030E-01 O.OOOE+00 4.450E+04 0.OOOE+00 3.180E-01 NB-95 5.930E+05 2.440E+05 0.OOOE+00 1.750E+05 0.OOOE+00 2.060E+08 0.OOOE+00 1.410E+05 MO-99 0.OOOE+00 2.080E+08 0.OOOE+00 3.11 OE+08 0.OOOE+00 6.850E+07 0.OOOE+00 4.060E+07 TC-99M 2.750E+01 5.670E+01 0.OOOE+00 6.100E+02 2.960E+01 1.650E+04 0.OOOE+00 7.300E+02 TC-101 2.470E-59 3.110E-59 0.OOOE+00 3.700E-58 1.700E-59 5.280E-57 0.OOOE+00 3.080E-58 RU-103 8.670E+03 0.000E+00 0.OOOE+00 1.800E+04 0.OOOE+00 1.050E+05 0.OOOE+00 2.900E+03 RU-105 8.050E-03 0.OOOE+00 0.OOOE+00 5.920E-02 0.OOOE+00 3.200E+00 0.OOOE+00 2.710E-03 RU-106 1.900E+05 0.OOOE+00 0.OOOE+00 2.250E+05 0.OOOE+00 1.4.40E+06 0.OOOE+00 2.380E+04 AG-110M 3.860E+08 2.820E+08 0.OOOE+00 4.030E+08 0.OOOE+00 1.460E+10 0.OOOE+00 1.860E+08 TE-125M 1.510E+08 5.040E+07 5.070E+07 0.000E+00 0.OOOE+00 7.180E+07 0.OOOE+00 2.040E+07 TE-127 6.320E+03 2.120E+03 5.140E+03 1.540E+04 0.OOOE+00 1.330E+05 0.OOOE+00 1.360E+03 TE-127M 4.210E+08 1.400E+08 1.220E+08 1.040E+09 0.OOOE+00 1.700E+08 0:OOOE+00 5.100E+07 TE-129 2.720E-09 9.380E-10 2.280E-09 6.770E-09 0,0OOE+00 2.170E-07 0.OOOE+00 6.350E-10 TE-129M 5.570E+08

- 1.910E+08 2.140E+08 1.390E+09 0.000E+00 3.330E+08 0.OOOE+00 8.580E+07 TE-131 3.430E-32 1.270E-32 3.060E-32 8.760E-32 0.OOOE+00 1.380E-30 0.OOOE+00 9.610E-33 TE-131M 3.380E+06 1.360E+06 2.750E+06 9.350E+06 0.000E+00 2.290E+07 0.000E+00 1.120E+06 TE-132 2.11OE+07 1.040E+07 1.540E+07 6.530E+07 0.OOOE+00 3.870E+07 0.OOOE+00 9.750E+06 1-130 3.550E+06 7.81 OE+06 8.750E+08 8.580E+06 0.OOOE+00 1.670E+06 0.000E+00 3.130E+06 Appendix J Ri Infant Cow Milk - Page 2 of 3

0 January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX J Ri Infant Dose Factors for use in the Gaseous Dose Calculations 2

Agegroup:

INFANT Pathway:

Grs/Cow/Milk (CMILK)

Units:

m 2mrem/yr / J4Ci/sec; mrem/yr /.tCi/m3 (H-3)

NiicidO

, Bone.

LiveVr

-Thyrojid~

Kidney ILun~gK iGlilli< 1 Skin Tota B~ody 1-131 2.720E+09 3.200E+09 1.050E+12 3.740E+09 0.OOOE+00

.1.140E+08 0.OOOE+00 1.410E+09 1-132 1.430E+00 2.900E+00 1.360E+02 3.240E+00 0.000E+00 2.350E+00 0.OOOE+00 1.030E+00 1-133 3.630E+07 5.280E+07 9.600E+09 6.210E+07 0.OOOE+00 8.930E+06 0.OOOE+00 1.550E+07 1-134 1.760E-11 3.600E-11 8.400E-10 4.030E-11 0.OOOE+00 3.720E-11 0.OOOE+00 1.280E-11 1-135 1.120E+05 2.230E+05 2.OOOE+07 2.490E+05 0.OOOE+00 8.080E+04 0.OOOE+00 8.140E+04 CS-134 3.650E+10 6.800E+10 0.OOOE+00 1.750E+10 7.180E+09 1.850E+08 0.OOOE+00 6.870E+09 CS-136 1.980E+09 5.810E+09 0.OOOE+00 2.320E+09 4.740E+08 8.820E+07 0.OOOE+00 2.170E+09 CS-137 5.150E+10 6.020E+10 0.OOOE+00 1.620E+10 6.550E+09 1.880E+08 0.OOOE+00 4.270E+09 CS-138 8.390E-23 1.360E-22 0.OOOE+00 6.800E-23 1.060E-23 2.180E-22 0.OOOE+00 6.610E-23 BA-139 4.270E-07 2.830E-10 0.OOOE+00

-1.700E-10 1.720E-10 2.710E-05 0.OOOE+00 1.240E-08 BA-140 2.410E+08 2.410E+05 0.OOOE+00 5.720E+04 1.480E+05 5.920E+07 0.OOOE+00 1.240E+07 BA-141 3.930E-45 2.690E-48 0.OOOE+00 1.620E-48 1.640E-48 4.800E-44 0.OOOE+00 1.240E-46 BA-142 2.430E-79 2.020E-82 0.OOOE+00 1.160E-82 1.220E-82 1.OOOE-78 0.OOOE+00 1.200E-80 LA-140 4.050E+01 1.600E+01 0.OOOE+00 0.000E+00 0.OOOE+00 1.880E+05 0.000E+00 4.1 10E+00 LA-142 1.700E-10 6.250E-11 0.003E+00 0.000E+00 0.OOOE+00 1.060E-05 0.OOOE+00 1.500E-11 CE-141 4.340E+04 2.640E+04 0.OOOE+00 8.150E+03 0.OOOE+00 1.370E+07 0.OOOE+00 3.11OE+03 CE-143 3.970E+02 2.630E+05 0.OOOE+00 7.670E+01 0.OOOE+00 1.540E+06 0.OOOE+00 3.OOOE+01 CE-144 2.330E+06 9.520E+05 0.OOOE+00 3.850E+05 0.OOOE+00 1.330E+08 0.OOOE+00 1.300E+05 PR-143 1.490E+03 5.550E+02 0.OOOE+00 2.060E+02 0.OOOE+00 7.840E+05 0.000E+00 7.360E+01 PR-144 5.690E-53 2.200E-53 0.OOOE+00 7.980E-54 0.OOOE+00 1.020E-48 0.000E+00 2.870E-54 ND-147 8.810E+02 9.050E+02 0.OOOE+00 3.490E+02 0.OOOE+00 5.740E+05 0.OOOE+00 5.550E+01 W-187 6.080E+04 4.230E+04 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.480E+66 0.OOOE+00 1.460E+04 NP-239 3.650E+01 3.260E+00 0.OOOE+00 6.510E+00 0.OOOE+00 9.430E+04 0.OOOE+00 1.840E+00 Appendix J Ri Infant Cow Milk - Page 3 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

Rh Infant Dose January, 2010 Revision 52 APPENDIX J Factors for use in the Gaseous Dose Calculations W. Infant DoseFactors for use in the Gaseous Dose Calculations Agegroup:

INFANT Pathway:

Grs/Goat/Milk (GMILK)

Units: -

m 2.mrem/yr / XCi/sec;

__mrem/yr

/ iCi/m3 (H-3)

.Nuc.ide.

gone.

Liver TliyroId.

.Kio.ey Lunig..

Gilli Skin TotalBo Id 11y H-3 0.OOOE+00 4.860E+03 4.860E+03 4.860E+03 4.860E+03 4.860E+03 0.OOOE+00 4.860E+03 C-14 2.340E+09 5.OOOE+08 5.OOOE+08 5.OOOE+08 5.000E+08 5.OOOE+08 0.OOOE+00 5'.OOOE+08 NA-24 1.850E+06 1.850E+06 1.850E+06 1.850E+06 1.850E+06 1.850E+06 0.OOOE+00 1.850E+06 P-32 1.920E+1 1 1.130E+10 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.600E+09 0.OOOE+00 7.460E+09 CR-51 0.OOOE+00 0.OOOE+00 1.260E+04 2.760E+03 2.460E+04 5.640E+05 0.OOOE+00 1.940E+04 MN-54 0.OOOE+00 4.680E+06 0.OOOE+00 1.040E+06 0.OOOE+00 1.720E+06 0.OOOE+00 1.060E+06 MN-56 0.OOOE+00 3.720E-03 O.OOOE+00 3.190E-03 O.OOOE+00 3.380E-01 0.OOOE+00 6.410E-04 FE-55 1.760E+06 1:130E+06 0.OOOE+00 O.OOOE+00 5.550E+05 1.440E+05 0.OOOE+00 3.030E+05 FE-59 2.920E+06 5.100E+06 0.OOOE+00 0.OOOE+00 1.510E+06 -

2.430E+06 0.OOOE+00 2.010E+06 CO-58 0.OOOE+00 2.910E+06 0.OOOE+00 0.OOOE+00 0.OOOE+00 7.250E+06 0.OOOE+00 7.260E+06 CO-60 0.OOOE+00 1.060E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.520E+07 0.000E+06 2.500E+07 NI-63 4.190E+09 2.590E+08 0.OOOE+00 0.OOOE+00 0.000E+00 1.290E+07 0.OOOE+00 1.450E+08 NI-65 4.210E-01 4.760E-02 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.620E+00 0.OOOE+00 2.170E-02 CU-64 0.OOOE+00 2.070E+04 0.OOOE+00 3.500E+04 0.OOOE+00 4.240E+05 0.OOOE+00 9.570E+03 ZN-65 6.660E+08 2.280E+09 0.OOOE+00 1.11OE+09 0.000E+00 1.930E+09 0.OOOE+00 1.050E+09 ZN-69 2.420E-12 4.360E-12 0.OOOE+00 1.810E-12 0.OOOE+00 3.550E-10 0.000E+00 3.240E-13 BR-83 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 1.120E-01 BR-84 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 1.510E-23 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RB-86 0.OOOE+00 2.670E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.830E+07 0.OOOE+00 1.320E+09 RB-88 0.OOOE+00 2.250E-45 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.190E-45 0.OOOE+00 1.230E-45 RB-89 0.000E+00 3.940E-53 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.340E-53, 0.OOOE+00 2.720E-53 SR-89 2.640E+10 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 5.430E+08 0.OOOE+00 7.580E+08 SR-90 2.550E+1 I 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 3.190E+09 0.OOOE+00 6.500E+10 SR-91 5.700E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.750E+05 0.OOOE+00 2.060E+04 Appendix J Ri Infant Goat Milk - Page 1 of 3

January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX J Ri Infant Dose Factors for use in the Gaseous Dose Calculations Agegroup:,

INFANT Pathway:

Grs/Goat/Milk (GMILK) 2 l"Units:

m2mrem/yr / p.Ci/sec;

-.i* *:

mrem/yr/

(Ci/mi1--3)

Nuclide

.Bone

  • ,Liver..-..'

Thyroid- -'Kidne)ey Lung]-

GiliI*i SkinOj dTta

Boy, SR-92 9.750E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.050E+02 0.OOOE+00 3.620E-01 Y-90 8.170E+01 0.000E+00 0.000E+00 0.OOOE+00 0.OOOE+00 1.130E+05 6.OOOE+00 2.190E+00 Y-91 8.790E+03 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.300E+05 0.OOOE+00 2.340E+02 Y-91M 6.810E-20 0.000E+00 0.000E+00 0.OOOE+00 0.OOOE+00 2.270E-16 0.OOOE+00 2.320E-21 Y-92 6.450E-05 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.230E+00 0.OOOE+00 1.810E-06 Y-93 2.590E-01 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 2.040E+03 0.OOOE+00 7.050E-03 ZR-95 8.170E+02 1.990E+02 0.OOOE+00 2.140E+02 0.OOOE+00 9.910E+04 0.OOOE+00 1.410E+02 ZR-97 4.870E-01 8.360E-02 0.000E+00 8.430E-02 0.OOOE+00 5.340E+03 0.OOOE+00 3.820E-02 NB-95 7.120E+04 2.930E+04 0.OOOE+00 2.100E+04 0.000E+00 2.480E+07 0.000E+00 1.700E+04 MO-99 0.000E+00 2.500E+07 0.OOOE+00 3.730E+07 0.000E+00 8.220E+06 0.000E+00 4.870E+06 TC-99M 3.300E+00 6.800E+00 0.OOOE+00 7.320E+01 3.550E+00 1.970E+03 0.000E+00 8.760E+01 TC-101 2.960E-60 3.730E-60 0.OOOE+00 4.440E-59 2.030E-60 6.340E-58 0.OOOE+00 3.690E-59 RU-103 1.040E+03 O.OOOE+00 0.OOOE+00 2.170E+03 0.OOOE+00 1.270E+04 0.000E+00 3.480E+02 RU-105 9.660E-04 0.OOOE+00 0.000E+00 7.11 OE-03 0.OOOE+00 3.840E-01 0.OOOE+00 3.250E-04 RU-106 2.280E+04 0.000E+00 0.OOOE+00 2.700E+04 0.OOOE+00 1.730E+05 0.OOOE+00 2.850E+03 AG-i IOM 4.630E+07 3.380E+07 0:000E+00 4.830E+07 0.OOOE+00 1.750E+09 0.000E+00 2.240E+07 TE-125M 1.810E+07 6.050E+06 6.090E+06 0.OOOE+00 0.OOOE+00 8.620E+06 0.000E+00 2.450E+06 TE-127 7.580E+02 2.540E+02 6.170E+02 1.850E+03 0.OOOE+00 1.590E+04 0.000E+00 1.630E+02 TE-127M 5.050E+07 1.680E+07 1.460E+07 1.240E+08 0.OOOE+00 2.040E+07 0.OOOE+00 6.120E+06 TE-129 3.260E-10 1.130E-10 2.740E-10 8.130E-10 0.OOOE+00 2.610E-08 0.OOOE+00 7.620E-11 TE-129M 6.690E+07 2.290E+07 2.570E+07 1.670E+08 0.OOOE+00 3.990E+07 0.000E+00 1.030E+07 TE-131 A.11OE-33 1.520E-33 3.670E-33 1.050E-32 0.OOOE+00 1.660E-31 0.000E+00 1.150E-33 TE-131M 4.050E+05 1.630E+05 3.3 1OE+05 1.120E+06 0.OOOE+00 2.750E+06 0.000E+00 1.350E+05 TE-132 2.530E+06 1.250E+06 1.850E+06 7.840E+06 0.OOOE+00 4.640E+06 0.OOOE+00 1.170E+06.

1-130 4.260E+06 9.370E+06 1.050E+09 1.030E+07 0.OOOE+00 2.010E+06 0.OOOE+00 3.760E+06 Appendix J Ri Infant Goat Milk - Page 2 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX J R1 Infant Dose Factors for use in the Gaseous Dose Calculations 2

Agegroup:

INFANT Pathway:

Grs/Goat/Milk (GMILK)

Units:

m mrem/yr / JtCi/sec; mrem/ycr / Ci/m 3 1-3)

Nuclide Bone Liver Thyroid Kidney Lungý Gilli Skin

,Ttal Body 1-131 3.260E+09 3.850E+09 1.260E+12 4.490E+09 0.OOOE+00 1.370E+08 0.OOOE+00 1.690E+09 1-132 1.720E+00 3.480E+00 1.630E+02 3.890E+60 0.OOOE+00 2.820E+00 0.000E+00 1.240E+00 1-133 4.350E+07 6.340E+07 1.150E+10 7.450E+07 0.000E+00 1.070E+07 0.OOOE+00 1.860E+07 1-134 2.11OE-11 4.320E-11 1.010E-09 4.830E-I1 0.000E+00 4.470E-11 O.000E+00 1.540E-11 1-135 1.350E+05 2.680E+05 2.400E+07 2.990E+05 0.OOOE+00 9.700E+04 0.OOOE+00 9.770E+04 CS-134 1.090E+1I 2.040E+11 0.OOOE+00 5.250E+10 2.150E+10 5.540E+08 0.OOOE+00 2.060E+10 CS-136 5.930E+09 1.740E+10 0.OOOE+00 6.950E+09 1.420E+09 2.650E+08 0.OOOE+00 6.5 1OE+09 CS-137 1.540E+11 1.810E+11 0.OOOE+00 4.850E+10 1.960E+10 5.650E+08 0.OOOE+00 1.280E+10 CS-138 2.520E-22 4.090E-22 0.OOOE+00 2.040E-22 3.190E-23 6.540E-22 0.OOOE+00 1.980E-22 BA-139 5.130E-08 3.400E-1 0.OOOE+00 2.040E-1I 2.060E-1I 3.250E-06 0.OOOE+00 1.480E-09 BA-140 2.890E+07 2.890E+04 0.OOOE+00 6.870E+03 1.780E+04 7.100E+06 0.OOOE+00 1.490E+06 BA-141 4.720E-46 3.230E-49 0.OOOE+00 1.940E-49 1.960E-49 5.760E-45 0.OOOE+00 1.490E-47 BA-142 2.920E-80 2.430E-83 0.OOOE+00 1.400E-83 1.470E-83 1.200E-79 0.OOOE+00 1.440E-81 LA-140 4.860E+00 1.920E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.250E+04 0.OOOE+00 4.930E-01 LA-142 2.040E-1 1 7.500E-12 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.270E-06 0.OOOE+00 1.790E-12 CE-141 5.200E+03 3.170E+03 0.OOOE+00 9.790E+02 0.000E+00 1.640E+06 0.000E+00 3.740E+02 CE-143 4.760E+01 3.160E+04.

0.OOOE+00 9.200E+00 0.OOOE+00 1.840E+05 0.OOOE+00 3.600E+00 CE-144 2.790E+05 1.140E+05 0.OOOE+00 4.620E+04 0.OOOE+00 1.600E+07 0:000E+00 1.560E+04 PR-143 1.780E+02 6.670E+01 0.OOOE+00 2.480E+01 0.OOOE+00 9.410E+04 0.OOOE+00 8.840E+00 PR-144 6.830E-54 2.640E-54 0.OOOE+00 9.570E-55 0.006E+00 1.230E-49 0.OOOE+00 3.440E-55 ND-147 1.060E+02 1.090E+02 O.OOOE+00 4.190E+01 0.OOOE+00 6.880E+04 0.OOOE+00 6.650E+00 W-187 7.300E+03 5.070E+03 0.OOOE+00 0.000E+00 0.OOOE+00 2.980E+05 0.OOOE+00 1.750E+03 NP-239 4.380E+00 3.910E-01 0.OOOE+00 7.810E-01 0.OOOE+00 1.130E+04 0.000E+00 2.210E-01 Appendix J Ri Infant Goat Milk - Page 3 of 3

0 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX J R1 Infant DoseFactors for use in the Gaseous Dose Calculations Agegroup:

INFANT Pathway:

Inhalation (INHL)

Units:

mrem/yr / jt&i/m 3 Nuclide Bo11ni e' Liver., A hyroid Ki,.Vdney Lu.

AA GI

' Skin:

ioa oy H-3 0.OOOE+00 6.470E+02 6.470E+02 6.470E+02 6.470E+02 6.470E+02 0.OOOE+00 6.470E+02 C-14 2.650E+04 5.310E+03 5.310E+03 5.310E+03 5.310E+03 5.310E+03 0.OOOE+00 5.310E+03 NA-24 1.060E+04 1.060E+04 1.060E+04 1.060E+04 1.060E+04 1.060E+04 0.OOOE+00 1.060E+04 P-32 2.030E+06 1.120E+05 0.OOOE+00 0.000E+00 0.OOOE+00 1.610E+04 0.OOOE+00 7.740E+04 CR-5 1 O.000E+00 0.OOOE+00 5.750E+01 1.320E+01 1.280E+04 3.570E+02 0.OOOE+00 8.950E+01 MN-54 0.OOOE+00 2.530E+04 0.OOOE+00 4.980E+03 1.000E+06 7.060E+03 0.OOOE+00 4.980E+03 MN-56 0.OOOE+00 1.540E+00 0.OOOE+00 1.100E+00 1.250E+04 7.170E+04 0.000E+00 2.210E-01.

FE-55 1.970E+04 1.170E+04 0.OOOE+00 0.OOOE+00 8.690E+04 1.090E+03 0.OOOE+00 3.330E+03 FE-59 1:360E+04 2.350E+04 0.OOOE+00 0.OOOE+00 1.010E+06 2.480E+04 0.00OE+00 9.480E+03 CO-58 0.000E+00 1.220E+03 0.OOOE+00 0.OOOE+00 7.770E+05 1.11OE+04 0.OOOE+00 1.820E+03 CO-60 0.OOOE+00 8.020E+03 0.000E+00 0.OOOE+00 4.510E+06 3.190E+04 0.OOOE+00 1.180E+04 NI-63 3.390E+05 2.040E+04 0.OOOE+00 0.OOOE+00 2.090E+05 2.420E+03 0.OOOE+00 1.160E+04 NI-65 2.390E+00 2.840E-01 0.OOOE+00 0.OOOE+00 8.120E+03 5.010E+04 0.OOOE+00>

1.230E-01 CU-64 O.OOOE+00 1.880E+00 0.OOOE+00 3.980E+00 9.300E+03 1.500E+04 0.OOOE+00 7.740E-01 ZN-65 1.930E+04 6.260E+04 0.OOOE+00 3.250E+04 6.470E+05 5.140E+04 0.OOOE+00 3.11OE+04 ZN-69 5.390E-02 9.670E-02 0.OOOE+00 4.020E-02 1.470E+03 1.320E+04 0.OOOE+00 7.180E-03 BR-83 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 3.810E+02 BR-84 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.000E+02 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 2.040E+01 RB-86 0.OOOE+00 1.900E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.040E+03 0.000E+00 8.820E+04 RB-88 0.OOOE+00 5.570E+02 0.OOOE+00 0.OOOE+00 O.000E+00 3.390E+02 0.000E+00 2.870E+02 RB-89 0.0003E+00 3.210E+02 0.OOOE+00 0.OOOE+00 O.OOOE+00 6.820E+01 0.OOOE+00 2.060E+02 SR-89 3.980E+05 0.OOOE+00 0.000E+00 0.OOOE+00 2.030E+06 6.400E+04 0.OOOE+00 1.140E+04 SR-90

,4.090E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.120E+07 1.3 10E+05 0.OOOE+00 2.590E+06 SR-91 9.560E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.260E+04 7.340E+04 0.OOOE+00 3.460E+00 Appendix J Ri Infant Inhalation - Page 1 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX J R1 Infant Dose Factors for use in the Gaseous Dose Calculations Agegrouip:

INFANT Pathway:

Inhalation (INHL)

UnitS:

mrem/yr / giCi/m 3 Nuclide:'

Bone': ?

Liver Thyroid

-kdney Luig<

Gilli sKin <9

  • TotaI Body*

SR-92 1.050E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.380E+04 1.400E+05 0.OOOE+00 3.910E-01 Y-90 3.290E+03 0.OOOE+00 0.006E+00 0.OOOE+00 2.690E+05 1.040E+05 0.OOOE+00 8.820E+01 Y-91 5.880E+05 0.000E+00 0.OOOE+00 0.OOOE+00 2.450E+06 7.030E+04 0.OOOE+00 1.570E+04 Y-91M 4.070E-01 0.000E+00 0.OOOE+00 0.OOOE+00 2.790E+03 2.350E+03 0.OOOE+00 1.390E-02 Y-92 1.640E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.450E+04 1.270E+05 0.OOOE+00 4.610E-01 Y-93 1.500E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 7.640E+04 1.670E+05 0.OOOE+00 4.070E+00 ZR-95 1.150E+05 2.790E+04 0.OOOE+00 3.110E+04 1.750E+06 2.170E+04 0.OOOE+00 2.030E+04 ZR-97 1.500E+02 2.560E+01 0.OOOE+00 2.590E+01 1.100E+05 1.400E+05 0.OOOE+00 1.170E+01 NB-95 1.570E+04 6.430E+03 0.OOOE+00 4.720E+03 4.790E+05 1.270E+04 0.OOOE+00 3.780E+03 MO-99 0.OOOE+00 1.650E+02 0.OOOE+00 2.650E+02 1.350E+05 4.870E+04 0.OOOE+00 3.230E+01 TC-99M 1.400E-03 2.880E-03 0.OOOE+00 3.11OE-02 8.110E+02 2.030E+03 0.OOOE+00 3.720E-02 TC-101 6.510E-05 8.230E-05 0.OOOE+00 9.790E-04 5.840E+02 8.440E+02 0.OOOE+00 8.120E-04 RU-103 2.020E+03 0.OOOE+00 0.OOOE+00 4.240E+03 5.520E+05 1.610E+04 0.OOOE+00 6.790E+02 RU-105 1.220E+00 0.OOOE+00 0.OOOE+00 8.990E-01 1.570E+04 4.840E+04 0.OOOE+00 4.100E-01 RU-106 8.680E+04 0.OOOE+00 0.OOOE+00 1.070E+05 1.160E+07 1.640E+05 0.OOOE+00 1.090E+04 AG-110M 9.980E+03 7.220E+03 0.OOOE+00 1.090E+04 3.670E+06 3.300E+04 0.OOOE+00 5.OOOE+03 TE-125M 4.760E+03 1.990E+03 1.620E+03 0.OOOE+00 4.470E+05 1.290E+04 0.OOOE+00 6;580E+02 TE-127 2.230E+00 9.530E-01 1.850E+00 4.860E+00 1.030E+04 2.440E+04 0.000E+00 4.890E-01 TE-127M 1.670E+04 6.900E+03 4.870E+03 3.750E+04 1.310E+06 2.730E+04 0.OOOE+00 2.070E+03 TE-129 7.880E-02 3.470E-02 6.750E-02 1.750E-01 3.OOOE+03 2.630E+04 0.000E+00 1.880E-02 TE-129M 1.410E+04 6.090E+03 5.470E+03 3.180E+04 1.680E+06 6.900E+04 0.OOOE+00 2.230E+03 TE-131 1.740E-02 8.220E-03 1.580E-02 3.990E-02 2.060E+03 8.220E+03 0.OOOE+00 5.OOOE-03 TE-131M 1.070E+02 5.500E+01 8.930E+01 2.650E+02 1.990E+05 1.190E+05 0.OOOE+00 3.630E+01 TE-132 3.720E+02 2.370E+02 2.790E+02 1.030E+03 3.400E+05 4.410E+04 0.OOOE+/-00 1.760E+02 1-130

.6.360E+03 1.390E+04 1.600E+06 1.530E+04 0.OOOE+00 1.990E+03 0.OOOE+00 5.570E+03 Appendix J Ri Infant Inhalation - Page 2 of 3 9

-1 January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX J Ri Infant Dose Factors for use in the Gaseous Dose Calculations Agegroup:.

INFANT Pathway:

Inhalation (INHL)

Units".;,

mrem/yr / ýtCi/m 3 Nulide "Boiie K:

Liver Thyroid Kidney Lug Gilli

Skin".

Tot

_d a

oy.

1-131 3.790E+04 4.440E+04 1.480E+07 5.180E+04 0.OOOE+00 1.060E+03 0.OOOE+00 1.960E+04 1-132 1.690E+03 3.540E+03 1.690E+05 3.950E+03 0.OOOE+00 1.900E+03 0.OOOE+00 1.260E+03 1-133 1.320E+04 1.920E+04 3.560E+06 2.240E+04 0.OOOE+00 2.160E+03 0.OOOE+00 5.600E+03 1-134 9.210E+02 1.880E+03 4.450E+04 2.090E+03 0.OOOE+00 1.290E+03 0.OOOE+00 6.650E+02 1-135 3.860E+03 7.600E+03 6.960E+05 8.470E+03 0.000E+00 1.830E+03 0.OOOE+00 2.770E+03 CS-134 3.960E+05 7.030E+05 0.OOOE+00 1.900E+05 7.970E+04 1.330E+03 0.OOOE+00 7.450E+04 CS-136 4.830E+04 1.350E+05 0.OOOE+00 5.640E+04 1.180E+04 1.430E+03 0.OOOE+00 5.290E+04 CS-137 5.490E+05 6.120E+05 0.000E+00 1.720E+05 7.130E+04 1.330E+03 0.OOOE+00 4.550E+04 CS-138 5.050E+02 7.810E+02 0.OOOE+00 4.100E+02 6.540E+01 8.760E+02 0.OOOE+00 3.980E+02 BA-139 1.480E+00 9.840E-04 0.OOOE+00 5.920E-04 5.950E+03 5.100E+04 0.000E+00 4.300E-02 BA-140 5.600E+04 5.600E+01 0.OOOE+00

.1.340E+01 1.600E+06 3.840E+04 0.OOOE+00 2.900E+03 BA-141 1.570E-01 1.080E-04 0.OOOE+00 6.500E-05 2.970E+03 4.750E+03 0.OOOE+00 4.970E-03 BA-142 3.980E-02 3.300E-05 0.000E+00 1.900E-05 1.550E+03 6.930E+02 0.000E+00.

1.960E-03 LA-140 5.050E+02 2.OOOE+02 0.OOOE+00 0.OOOE+00 1.680E+05 8.480E+04 0.OOOE+00 5.150E+01 LA-142 1.030E+00 3.770E-01 0.OOOE+00 0.OOOE+00 8.220E+03 5.950E+04 0.OOOE+00 9.040E-02 CE-141 2.770E+04 1.670E+04 0.OOOE+00 5.250E+03 5.170E+05 2.160E+04 0.OOOE+00 1.990E+03 CE-143 2.930E+02 1.930E+02 0.OOOE+00 5.640E+01 1.160E+05 4.970E+04 0.OOOE+00 2.21OE++/-01 CE-144

.3.190E+06 1.210E+06 0.OOOE+00 5.380E+05 9.840E+06 1.480E+05-0.OOOE+00 1.760E+05 PR-143 1.400E+04 5.240E+03 0.OOOE+00 1.970E+03 4.330E+05 3.720E+04 0.OOOE+00 6.990E+02 PR-144 4.790E-02 1.850E-02 0.OOOE+00 6.720E-03 1.610E+03 4.280E+03 0.OOOE+00 2.410E-03 ND-147 7.940E+03 8.130E+03 0.OOOE+00 3.150E+03 3.220E+05 3.120E+04 0.OOOE+00 5.000E+02 W-187 1.300E+01 9.020E+00 O.OOOE+00 0.OOOE+00 3.960E+04 3.560E+04 0.OOOE+00 3.120E+00 NP-239 3.710E+-02 3.320E+01 0.OOOE+00 6.620E+01 5.950E+04 2.490E+04 O.OOOE+00 1.880E+01 Appendix J Ri Infant Inhalation - Page 3 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX J K Infant Dose Factors for use in the Gaseous Dose Calculations Agegroup:

INFANT Pathway:

Ground Plane Deposition (GPD)

Units:,

I m2.mrem/yr / jtCi/sec

'Nuclide-;

Bone Liver

'Thyroid

Kidney, (L

- Gilli Skin :9 Total Body=i H-3 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 C-14 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 0.OOOE+00 NA-24 1.190E+07 1.190E+07 1.1 90E+07 1.190E+07

1. 190E1+07 1.190E+07 1.390E+07 1.1 90E+07 P-32 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+06 0.OOOE+00 CR-51 4.660E+06 4.660E+06 4.660E+06 4.660E+06 4.660E+06 4.660E+06 5.5 1OE+06 4.660E+06 MN-54 1.390E+09 1.390E+09 1.390E+09 1,390E+09 1.390E+09 1.390E+09 1.630E+09 1.390E+09 MN-56 9.020E+05 9.020E+05 9.020E+05 9.020E+05 9.020E+05 1.070E+06 9.020E+05 FE-55 0.OOOE+00 0.000E+00 0.000E+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 FE-59 2.730E+08 2.730E+08 2.730E+08 2.730E+08 2.730E+08 2.730E+08 3.210E+08 2.730E+08 CO-58 3.790E+08 3.790E+08-3.790E+08 3.790E+08 3.790E+08 3.790E+08 4.440E+08 3.790E+08 CO-60 2.150E+10 2.150E+10 2.150E+10 2.150E+10 2.150E+10+

2.150E+10 2.530E+10 2.150E+10 NI-63 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 NI-65 2.970E+05 2.970E+05 2.970E+05 2.970E+05 2.970E+05 2.970E+05 3.450E+05 2.970E+05 CU-64 6.070E+05 6.070E+05 6.070E+05 6.070E+05 6.070E+05 6.070E+05 6.880E+05 6.070E+05 ZN-65 7.470E+08 7.470E+08 7.470E+08 7.470E+08 7,470E+08 7.470E+08 8.590E+08 7.470E+08 ZN-69 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 BR-83 4.870E+03 4.870E+03 4.870E+03 4.870E+03 4.870E+03 4.870E+03 7.080E+03 4.870E+03 BR-84 2.030E+05 2.030E+05 2.030E+05 2.030E+05 2.030E+05 2.030E+05 2.360E+05 2.030E+05 BR-85 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 RB-86 8.990E+06 8.990E+06 8.990E+06 8.990E+06 8.990E+06 8.990E+06 1.030E+07

'8.990E+06 RB-88 3.310E+04 3.310E+04 3.310E+04 3.310E+04 3.310E+04 3.310E+04 3.780E+04 3.310E+04 RB-89 1.230E+05 1.230E+05 1.230E+05 1.230E+05 1.230E+05 1.230E+05 1.480E+05 1,230E+05 SR-89 2.160E+04 2.160E+04 2.160E+04 2.160E+04 2.160E+04 2.160E+04 2.510E+04 2.160E+04 SR-90 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 SR-91 2.150E+06 2.150E+06 2.150E+06 2.150E+06 2.150E+06 2.150E+06 2.510E+06 2.150E+06 Appendix J Ri Infant Ground Plane Deposition - Page 1 of 3 9

0

9 January, 2010 Revision 52 Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

APPENDIX J R1 Infant Dose Factors for use in the Gaseous Dose Calculations Agegroup:

INFANT

'Pathway:

Ground Plane Deposition (GPD)

Units-*:.

m 2.mrem/yr / p.Ci/sec NUclide Bone

.Liver.

Thyroid. -

Kidney-'

Lung:.

Gilli Skin TotalBody SR-92 7.770E+05 7.770E+05 7.770E+05 7.770E+05 7.770E+05 7.770E+05 8.630E+05 7.770E+05 Y-90 4.490E+03

.4.490E+03 4.490E+03 4.490E+03 4.490E+03 4.490E+03 5.310E+03 4.490E+03 Y-91 1.070E+06 1.070E+06 1.070E+06 1.070E+06 1.070E+06 1.070E+06 1.210E+06 1.070E+06 Y-91M 1.000E+05 1.000E+05 1.000E+05 1.000E+05 1.OOOE+05 1.000E+05 1.160E+05 1.000E+05 Y-92 1.800E+05 1.800E+05 1.800E+05 1.800E+05 1.800E+05 1.800E+05 2.140E+05 1.800E+05 Y-93 1.830E+05 1.830E+05 1.830E+05 1.830E+05 1.830E+05 1.830E+05 2.510E+05 1.830E+05 ZR-95 2.450E+08 2.450E+08 2.450E+08 2.450E+08 2.450E+08 2.450E+08 2.840E+08 2.450E+08 ZR-97 2.960E+06 2.960E+06 2.960E+06 2.960E+06 2.960E+06 2.960E+06 3.440E+06 2.960E+06 NB-95 1.370E+08 1.370E+08 1.370E+08 1.370E+08 1.370E+08 1.370E+08 1.610E+08 1.370E+08 MO-99 3.990E+06 3.990E+06 3.990E+06 3.990E+06 3.990E+06 3.990E+06 4.630E+06 3.990E+06 TC-99M 1.840E+05 1.840E+05 1.840E+05 1.840E+05 1.840E+05 1.840E+05 2.1 10E+05 1.840E+05 TC-101 2.040E+04 2.040E+04 2.040E+04 2.040E+04 2.040E+04 2.040E+04 2.260E+04 2.040E+04 RU-103 1.080E+08 1.080E+08 1.080E+08 1.080E+08 1.080E+08 1.080E+08 1.260E+08*

1.080E+08 RU-105 6.360E+05 6.360E+05 6.360E+05 6.360E+05 6.360E+05 6.360E+05 7.210E+05 6.360E+05 RU-106 4.220E+08 4.220E+08 4.220E+08 4.220E+08 4.220E+08 4.220E+08 5.070E+08 4.220E+08 AG-110M 3.440E+09 3.440E+09 3.440E+09 3.440E+09 3.440E+09 3.440E+09 4.010E+09 3.440E+09 TE-125M 1.550E+06 1.550E+06 1.550E+06 1.550E+06 1.550E+06 1.550E+06 2.130E+06 1.550E+06 TE-127 2.980E+03 2.980E+03 2.980E+03 2.980E+03 2.980E+03 2.980E+03 3.280E+03 2.980E+03 TE-127M 9.160E+04 9.160E+04 9.160E+04 9.160E+04 9.160E+04 9.160E+04 1.080E+05 9.160E+04 TE-129 2.620E+04 2.620E+04 2.620E+04 2.620E+04 2.620E+04 2.620E+04 3.100E+04 2.620E+04 TE-129M 1.980E+07 1.980E+07 1.980E+07 1.980E+07 1.980E+07 1.980E+07 2.31 OE+07 1.980E+07 TE-131 2.920E+04 2.920E+04 2.920E+04 2.920E+04 2.920E+04 2.920E+04 3.450E+07 2.920E+04 TE-131M 8.030E+06 8.030E+06 8.030E+06 8.030E+06 8.030E+06 8.030E+06 9.460E+06 8.030E+06 TE-132 4.230E+06 4.230E+06 4.230E+06 4.230E+06 4.230E+06 4.230E+06 4.980E+06 4.230E+06 11-130 5.510E+06 5.510E+06 5.510E+06 5.510E+06 5.510E+06 5.510E+06 6.690E+06 5.510E+06 Appendix J Ri Infant Ground Plane Deposition - Page 2 of 3

Catawba Nuclear Station Offsite Dose Calculation Manual (ODCM)

January, 2010 Revision 52 APPENDIX J RK Infant Dose Factors for use in the Gaseous Dose Calculations Agegroup' INFANT Pathway:

Ground Plane Deposition (GPD)

Units:

m 2.mrem/yr / tCi/sec "Niiclide "Bone Liver Thyroid Kidney Lung Gilli

Skin, Total Body 1-131 1.720E+07 1.720E+07 1.720E+07 1.720E+07 1.720E+07 1.720E+07 2.090E+07 1.720E+07 1-132 1.250E+06 1.250E+06 1.250E+-06 1.250E+06 1.250E+06 1.250E+06 1.470E+06 1.250E+06 1-133 2.450E+06 2.450E+06 2.450E+06 2.450E+06 2.450E+06 2.450E+06 2.980E+06 2.450E+06 1-134 4.470E+05 4.470E+05 4.470E+05 4.470E+05 4.470E+05 4.470E+05 5.300E+05 4.470E+05 1-135 2.530E+06 2.530E+06 2.530E+06 2.530E+06 2.530E+06 2.530E+06 2.950E+06 2.530E+06 CS-134

.6.860E+09 6.860E+09 6.860E+09 6.860E+09 6.860E+09 6.860E+09 8.OOOE+09 6.860E+09 CS-136 1.510E+08 1.510E+08 1.510E+08 1.510E+08 1.510E+08 1.510E+08 1.710E+08 1.510E+08 CS-137 1.030E+10 1.030E+10 1.030E+10 1.030E+10 1.030E+10 1.030E+10 1.200E+10 1.030E+10 CS-138 3.590E+05 31590E+05 3.590E+05 3.590E+05 3.590E+05 3.590E+05 4.100E+05 3.590E+05 BA-139 1.060E+05 1.060E+05 1.060E+05 1.060E+05 1.060E+05 1.060E+05 1.190E+05 1.060E+05 BA-140 2.050E+07 2.050E+07 2.050E+07 2.050E+07 2.050E+07 2.050E+07 2.350E+07 2.050E+07 BA-141 4.170E+04 4.170E+04 4.170E+04 4.170E+04 4.170E+04 4.170E+04 4.750E+04 4.170E+04 BA-142 4.490E+04 4.490E+04 4.490E+04 4.490E+04 4.490E+04 4.490E+04 5.11OE+04 4.490E+04 LA-140 1.920E+07 1.920E+07 1.920E+07 1.920E+07 1.920E+07 1.920E+07 2.180E+07 1.920E+07 LA-142 7.600E+05 7.600E+05 7.600E+05 7.600E+05 7.600E+05 7.600E+05 9.120E+05 7.600E+05 CE-141 1.370E+07 1.370E+07 1.370E+07 1.370E+07 1.370E+07 1.370E+07 1.540E+07 1.370E+07 CE-143 2.310E+06 2.3 1OE+06 2.3 1OE+06 2.3 1OE+06 -

2.3 1OE+06 2.3 1OE+06 2.630E+06 2.310E+06 CE-144 6.950E+07 6.950E+07 6.950E+07 6-.950E+07 6.950E+07 6.950E+07 8.040E+07 6.950E+07 PR-143 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 PR-144 1.830E+03 1.830E+03 1.830E+03 1.830E+03 1.830E+03 1.830E+03 2.110E+03 1.830E+03 ND-147 8.390E+06 8.390E+06 8.390E+06 8.390E+06 8.390E+06 8.390E+06 1.010E+07 8.390E+06 W-187 2.350E+06 2.350E+06 2.350E+06 2.350E+06 2.350E+06 2.350E+06 2.730E+06 2.350E+06 NP-239 1.710E+06 1.710E+06 1.710E+06 1.710E+06 1.710E+06 1.710E+06 1.980E+06 1.710E+06 Appendix J Ri Infant Ground Plane Deposition - Page 3 of 3