Initial Examination 2009-301 Final RO Written Exam
ML090780607
Person / Time
Site: Oconee  
Issue date: 03/13/2009
From:
Division of Nuclear Materials Safety III
To:
References
Download: ML090780607 (79)


Text

'RO AN~WeR

\\~e'{

I I

Q#

Item #

Topic KEY

~

49 0

50 0

51 0

52 C

53 B

54 0

55 A

56 0

57 B

58 C

59 A

60 D

61 A

62 B

63 0

64 B

65 C

66 C

67 D

68 C

69 A

70 B

71 B

72 B

73 B

74 8

75 0

'RQ Af\\\\SW~ 'Lrr'{

'?~ lJ\\f \\\\) £t) R0

~EFttGl:1\\I G&~

List of RO Exam Attachments

  1. 17 AP/31Al17001034 Encl. 5.1 Generator Capability Curve - pgs 1 & 3 of 3
  1. 73 ARG for 1SA-03/ 8-6 (FIRE ALARM) which comes from OP/1/A/61 01/003

- pgs 1-7 and pgs 26 & 27

  1. 75 OP/O/A/1108/001 Enclosure 4.39 (page 1 only with action notes removed)

ES-401 Name:

Date: 03/13/2009 Region: II Start Time: 0900 Site:( ';eclfic Rervtr'ritten Examination Cover Sheet

u. S. Nuclear Regulatory Commission Site-Specific RO Written Examination Applicant Information Facility/Unit: Oconee 1, 2, 3 Reactor Type: BW Finish Time: 1500 Instructions Form ES-401-7 Use the answer sheets provided to document your answers. Staple this cover sheet on top of the answer sheets. To pass the examination you must achieve a final grade of at least 80.00 percent. Examination papers will be collected 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> after the examination starts.

Applicant Certification All work done on this examination is my own. I have neither given nor received aid.

Applicanfs Signature Results Examination Value Applicant's Score Applicant's Grade Points Points

_____ Points

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 1 Unit 1 initial conditions:

Reactor power = 100%

Current conditions:

Both Main FDWPs tripped Reactor power = 46%

decreasing All Main Turbine Stop Valves are open The generator breakers are closed (PCB-20 & PCB-21)

Based on the current conditions, which ONE of the following would be the required initial operator actions?

A. Manually insert control rods and initiate Emergency Boration B. Manually insert control rods and ensure both channels of AMSAC have actuated C. Place both EHC pumps in pull-to-Iock and initiate Emergency Boration D. Place both EHC pumps in pull-to-Iock and ensure both channels of AMSAC have actuated

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 2 Unit 2 initial conditions:

Mode 3 Startup in progress RCS temperature =350°F stable RCS Pressure = 1250 psig slowly decreasing Pressurizer Level =292 inches stable Quench Tank Level = 84 inches increasing Quench Tank pressure =5 psig slowly increasing The PORV is leaking Based on the above conditions, which ONE of the following describes the expected PORV tail pipe temperature (OF) and is the Pressurizer level exceeding the TS limit?

A. 265 / no B. 265 / yes C. 228 / no D. 228 / yes

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 3 Unit 1 initial conditions:

Reactor power = 100%

Current conditions:

SBLOCA 1A and 1B SG Levels at the LOSCM setpoint TBVs in AUTO and CLOSED Based on the above conditions, which ONE of the following combinations of parameters describes the indications that boiler-condenser mode heat transfer has been established?

RCS primary water level is

/ SG Pressures will A. below the SG secondary water level/increase until the TBV setpoint is reached B. below the SG secondary water level/decrease until SG pressure stabilizes at Tsat for the ReS temperature C. above the SG upper tube sheet / increase until the TBV setpoint is reached D. above the SG upper tube sheet / decrease until SG pressure stabilizes at Tsat for the RCS temperature

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 4 Unit 1 conditions:

RCS Pressure =200 psig decreasing HPI Flow in 1A Header =750 gpm HPI Flow in 1B Header =490 gpm Based on the conditions above, which ONE of the following describes the required operator actions to protect the HPI pumps?

A. Throttle HPI flows in BOTH 1A & 1B headers to <475 gpm per pump B. Throttle HPI flow in ONLY 1A header to <750 gpm C. Throttle HPI flows in BOTH 1A & 1B headers to <950 gpm combined D. Throttle HPI flow in ONLY 1B header to <475 gpm

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 5 Unit 1 initial conditions:

Reactor power =65%

1LPSW-6 (UNIT 1 RCP COOLERS SUPPLY) fails closed Current conditions:

AP/16 (Abnormal RCP Operation) in progress RCP Temperatures:

1A1 Upper Guide 182QF Bearing Temp Radial Bearing 219QF Temp 182 185Q Based on the above conditions, which ONE of the following is required per AP/16?

A. Manually trip the Reactor and stop ALL RCPs B. Manually trip the Reactor and stop RCPs 1A2 & 1B1 ONLY C. Stop RCP 1A2 ONLY and verify FDW re-ratios properly D. Stop RCP 1B1 ONLY and verify FDW re-ratios properly

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 6 Unit 1 plant conditions:

Time = 0400 Reactor power = 1000/0 1A HPI Pump operating 1B HPI Pump in AUTO Time =0401 1SA-2/C-2 (HP Injection Pump Disch Header Pressure Low) actuated 1SA-2/B-2 (HP Rep Seal Inlet Header Flow High/Low) actuated RCS makeup flow erratic and low 1A HPI Pump amps cycling Time = 0405 AP/14 (Loss Of Normal HPI Makeup and/or RCP Seal Injection) in progress Operators just completed Step 3.3, for stopping all HPI pumps Based on the conditions above, which ONE of the following describes the pump used to restore RCS makeup and the suction source used as directed by AP/14?

A. 1B HPI pump / BWST B. 1B HPI pump / LOST C. 1C HPI Pump / BWST O. 1C HPI Pump / LOST

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 7 Unit 1 initial conditions:

Normal LPI decay heat removal in service Current conditions:

Loss of offsite power occurs Power restored via CT-4 1A and 1B LPI Pumps not available Based on the above conditions, which ONE of the following describes the requirements to start the 1C LPI Pump to restore decay heat removal?

Manual reset of Load Shed is and starting of 1C LPI Pump is allowed after a minimum of secon"ds.

A. NOT required / 5 B. required / 5 C. NOT required / 30 D. required / 30

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 8 Unit 1 initial conditions:

Reactor power = 100%

NR RCS Pressure Channel "A" failed low NR RCS Pressure Channel "8" = 2155 psig stable NR RCS Pressure Channel "C" = 2158 psig stable NR RCS Pressure Channel "D" =2162 psig stable NR RCS Pressure Channel "E" =2148 psig stable Current conditions:

NR RCS Pressure Channel "E" failed low Based on the conditions above, which ONE of the following describes the impact on pzr Heaters and the response of the unit over the next 30 minutes?

ASSUME NO OPERATOR ACTION All pzr Heater controlled from the Unit 1 control room are...

A.

"ON" / Reactor will automatically trip B.

"ON" /

Reactor will NOT automatically trip C. NOT "ON" / Reactor will automatically trip D. NOT "ON" / Reactor will NOT automatically trip

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 9 Unit 3 initial conditions:

Reactor Power =95°10 decreasing RCS Pressure = 2455 psig increasing Tavg =598°F increasing Pressurizer level = 355 inches increasing Current conditions:

Reactor Power =4°1o decreasing RCS Pressure =2735 psig (maximum reached) decreasing Tavg =596°F decreasing Pressurizer level =365 inches decreasing Based on the conditions above, which ONE of the following describes whether or not the RCS Pressure safety limit has been exceeded and the bases for the safety limit?

The TS RCS Pressure Safety Limit has

. This Safety Limit A. been exceeded / ensures RCS pressure is maintained below 110°10 of design pressure to prevent RCS pressure boundary failure B. been exceeded / ensures that RCS pressure remains in the assumed range used in the analysis for reactivity accidents including slow rod withdrawal C. NOT been exceeded / ensures RCS pressure is maintained below 110°10 of design pressure to prevent RCS pressure boundary failure D. NOT been exceeded / ensures that RCS pressure remains in the assumed range used in the analysis for reactivity accidents including slow rod withdrawal

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 10 Unit 1 plant conditions:

Reactor Power =29%

decreasing Primary to secondary leakage in 1A SG pzr level = 160 inches decreasing ALL HPI Pumps running 1HP-26 and 1HP-27 open 1HP-5 closed Based on the conditions above, which ONE of the following describes whether 1RIA-59

& 1RIA-60 may be used to determine the SG Tube Leak Rate and what method will be used to shutdown per the EOP SGTR Tab?

1RIA-59 & 1RIA-60 __ to determine the SG Tube Leak Rate and the __

A. may be used / reactor is NOT required to be manually tripped B. may be used / reactor is required to be manually tripped C. may NOT be used / reactor is NOT required to be manually tripped D. may NOT be used / reactor is required to be manually tripped

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 11 Unit 1 conditions:

Reactor Tripped Main Turbine Control Valves are ALL closed Main Turbine Stop Valves 1 &3 (1 MS-1 05 & 103) are both open Based on the conditions above, which ONE of the following describes the action required (if any) and the reason action is (or is not) required?

A. No action is required / ALL Control Valves being closed isolates the Main Steam supply to the Main Turbine and prevents a post trip overcooling due to excessive steam flow.

B. No action is required / ALL Control Valves being closed isolates the Main Steam supply to the Main Turbine to prevent turbine damage from overspeeding following a generator trip from 100%

power.

C. Place both EHC Pumps in PULL TO LOCK / ALL Stop Valves must be closed to ensure the Main Steam Lines are isolated from each other to prevent a main steam line break from affecting both SGs.

D. Place both EHC Pumps in PULL TO LOCK / ALL Stop Valves must be closed to ensure the steam chest delta T requirements are not exceeded.

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 12 Unit 1 initial conditions:

Reactor power = 100%

Current conditions:

Station Blackout (power has NOT been restored)

RCS Temperatures 2 minutes after trip Tc = 550°F Th = 556°F CETCs = 558°F SG Pressures = 1010 psig stable Based on the conditions above, which ONE of the following describes the response of the RCS heat removal parameters during the transition but prior to establishing natural circulation?

RCS Tcold CETCs A. Increasing Increasing B. Decreasing Stable C. Stable Increasing D. Decreasing Increasing

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 13 Unit 1 initial conditions:

LBLOCA occurred 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> ago RCS Pressure = 30 psig 1A & 1B LPI Pumps are running Current conditions:

1KVIA is de-energized 1SA-181A-3 RVLIS/ICCM/RG 1.97 Train A Trouble actuated Based on the conditions above, which ONE of the following describes the impact on the LPI system instrumentation and what alternate indication can be used to determine the status of the LPI pumps?

A. LPI HDR 1A INJ FLOW (gpm) is Blank I 1A LPI Pump amps and breaker indicating lights B. LPI HDR 1A INJ FLOW (gpm) is Blank I 1A LPI HDR flow computer point (OAC)

C. LPI HDR 1B INJ FLOW (gpm) is Blank I 1B LPI Pump amps and breaker indicating lights D. LPI HDR 1B INJ FLOW (gpm) is Blank I 1B LPI HDR flow computer point (OAC)

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 14 Plant conditions:

Unit 1, 2, &3 Vital DC systems are aligned normally 1CA Battery Charger fails - output voltage = 0 VDC 1CA Battery voltage = 120 VDC 1DCB Bus voltage

= 123 VDC Unit 2 DCAlDCB Bus voltage = 125 VDC Unit 3 DCAlDCB Bus voltage = 127 VDC Based on the above conditions, which ONE of the following will supply power to 1DIA panelboard?

ASSUME NO OPERATOR ACTIONS A. 1CA Battery B. Unit 3 DC Bus C. 1DCB Bus D. Unit 2 DC Bus

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 15 Unit 3 initial conditions:

Reactor power = 100%

Current conditions:

LPSW header pressure =20 psig increasing Based on the above conditions, which ONE of the following describes the status of statalarm 3SA-9/C3 (LPSW Low Press RB Aux Cooler Isolation) and if the RBACs isolate, how is LPSW flow restored?

A. Actuated / Automatically when LPSW pressure returns above setpoint B. Actuated / Manually after depressing LPSW LOW PRESS DIG CH 1 AND 2 pushbuttons C. Not Actuated / Automatically when LPSW pressure returns above setpoint D. Not Actuated / Manually after depressing LPSW LOW PRESS DIG CH 1 AND 2 pushbuttons

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 16 Unit 1 initial conditions:

Reactor power = 100%

Instrument Air Pressure decreasing AP/22 (Loss of Instrument Air) initiated Current conditions:

Instrument Air pressure =61 psig decreasing FDW Pump ~P OAC alarms actuate 1A & 1B Main FDW Pump speeds are both increasing Based on the above conditions, which ONE of the following describes the actions required by AP/22?

A. Commence a plant shutdown. If at any time two or more CRD temperatures are

>180 QF, then trip the reactor.

B. Commence a plant shutdown. If at any time SG level approaches main FDW pump trip criteria, then trip the reactor.

C. Manually trip the reactor. Manually trip both main FDW pumps.

D. Manually trip the reactor. Take both FDW Masters to Hand and decrease demand to zero.

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 17 Unit 3 plant conditions:

A voltage disturbance is occurring AP/34 (Degrade Grid) initiated Power Factor is leading Generator Mwe = 800 Generator Hydrogen pressure = 60 psig Generator output voltage = 18.3 kV Based on the above conditions, which ONE of the following is the limit on MVARs in accordance with the Generator Capacity Curve?

REFERENCE PROVIDED A.325 B. 375 C. 410 D.550

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 18 Unit 1 plant conditions:

Loss of Heat Transfer exists due to the loss of ALL FDW sources HPI Forced Cooling in progress RCS pressure =2210 psig slowly decreasing pzr Level = 380 inches increasing Core SCM = 56°F increasing Based on the conditions above, which ONE of the following correctly completes the statement below regarding HPI throttling and the parameter/trend used to determine if the criteria for HPI throttling is met?

HPI flow be throttled because A. may NOT / RCS pressure is decreasing B. may NOT / CETCs are increasing C. may / pzr Level is increasing D. may / CETCs are decreasing

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 19 Unit 3 initial conditions:

Reactor power =100%

SASS is in MANUAL ALL PZR level Channels =220 inches pzr Level Channel 3 is selected Current conditions:

PZR temperature channel IIBII fails LOW Which ONE of the following describes how Standby Shutdown Facility (SSF) pzr Level indication will be initially affected by the above temperature failure and how will 3HP-120 respond to the failure?

SSF pzr Level indication will initially and 3HP-120 will A. decrease / be unaffected B. stay the same / be unaffected C. decrease / open D. stay the same / open

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 20 Plant initial conditions:

Unit 1 in MODE 6 De-fuel in progress Unit 2 in MODE 5 Unit 1 &2 RB Purge Fans running 1RIA-3 (Fuel Transfer Canal Wall) = 1.4 mr/hr 1RIA-6 (Spent Fuel Pool) = 1.72 mr/hr Current conditions:

1RIA-3 (Fuel Transfer Canal Wall) = 1.5 mr/hr 1RIA-6 (Spent Fuel Pool) = 15.2 mr/hr Based on the above conditions, which ONE of the following describes REQUIRED operator actions?

A. Stop Unit 1 RB Purge Fan and start a SFP Filtered exhaust fan.

B. Start ALL Outside Air Booster Fans and stop Unit 1 RB Purge Fan.

C. Stop Unit 2 RB Purge Fan and start a SFP Filtered exhaust fan.

D. Start ALL Outside Air Booster Fans and close ALL containment penetrations

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 21 Unit 1 plant conditions:

A Steam Generator Tube Rupture has occurred in the 111 BII SG ALL RCPs operating Which ONE of the following sets of parameters will result in the least amount of primary to secondary leakage?

RCS temperature is of.

RCS pressure is psig.

RCS Temp

/

RCS pressure A. 520

/

831 B. 532

/

890 C.540

/

987 0.552

/

1095

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 22 Unit 3 plant conditions:

Reactor power = 100 Main condenser vacuum = 28" Hg decreasing slowly Based on the above conditions, which ONE of the following describes the highest vacuum (inches Hg) at which a MANUAL Reactor Trip would be required per 3AP/27 (Loss of Condenser Vacuum)?

A.25 B. 22 C.20 D. 19

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 23 Unit 1 initial conditions:

Mode 6 Fuel assemblies are being loaded into the core All four SR Nls in service SR 1NI-1 and SR 1NI-3 are the designated Nls for Fuel Handling Current conditions:

Power supply to SR 1NI-1 fails (0 vdc)

Based on the above conditions, which ONE of the following describes the impact on fuel movement?

Fuel movement...

A. may continue because two SR Nls remain in service.

B. may continue because one of the designated SR Nls is still in service.

C. is required to be stopped until another SR NI is designated because other Nls are procedurally allowed to be designated.

D. is required to be stopped and cannot be resumed until SR 1NI-1 is returned to service because other Nls are NOT procedurally allowed to be designated.

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 24 Unit 3 initial conditions:

SBLOCA EOP ICC tab is in progress No ECCS injection sources are available 3RC-4 (PORV Block) is closed Current conditions:

3A &3B HPI pumps operating Conditions require the opening of 3RC-4 and establishing PORV flow to the Quench Tank Based on the above conditions, which ONE of the following describes actions required to operate 3RC-4 and the reason for establishing flow to the Quench Tank?

Position 3RC-4 switch to...

A. OPEN / increase HPI injection flow B. OPEN / elimination of non-condensable gases C. OPEN AND depress OPEN PERMIT / increase HPI injection flow D. OPEN AND depress OPEN PERMIT / elimination of non-condensable gases

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 25 Unit 3 plant conditions:

Control Room Evacuation complete due to a non-fire event ASDP has been "manned" Following indications are observed at the ASDP:

Turbine Header Pressure = 1011 psig and slowly decreasing TBVs demand is 12°k in Automatic and decreasing RCS T Hot = 560°F and slowly decreasing pzr Level = 140 inches increasing SG SU levels = 48 inches and increasing ALL RCPs are operating Based on the conditions above, which ONE of the following correctly describes the action(s) required (if any) per AP/8 (Loss of Control Room)?

The operator must take...

A. NO actions the plant is responding as expected.

B. manual control of TBVs to stabilize SG Pressure.

C. manual control and cycle 3B HPI pump to stabilize pzr level.

D. manual control of FDW Startup Control Valves and lower SG levels.

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 26 Boron precipitation is primarily a concern for a leg rupture. Failure to initiate the Boron Dilution flow path when required would challenge the ability to A. hot /

prevent boron stratification in the cold leg to ensure a restart event does not occur when the cold leg volume enters the core.

B. hot / ensure boron does not concentrate in the core and block the long term core cooling flow path C. cold / prevent boron stratification in the cold leg to ensure a restart event does not occur when the cold leg volume enters the core.

D. cold / ensure boron does not concentrate in the core and block the long term core cooling flow path

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 27 Unit 1 initial conditions:

Reactor power = 100%

ACB-3 closed Current conditions:

Switchyard Isolation RCS pressure = 1146 psig stable All SCM =21°F increasing Keowee Unit 2 emergency locked out Based on the above conditions, which ONE of the following describes the first procedure required to be performed by an RO after EOP IMAs and Symptoms Check are complete?

A. Enclosure 5.1 (ES Actuation)

B. Enclosure 5.2 (Placing RB Hydrogen Analyzers In Service)

C. Enclosure 5.5 (Pressurizer and LOST Level Control)

O. Enclosure 5.38 (Restoration of Power)

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 28 Unit 1 plant conditions:

Unit 1 startup in progress 1A1 and 1B1 RCPs are operating Based on the above conditions, which ONE of the following describes a condition that would prevent 1A2 RCP from starting?

B. RCP Oil Lift Pressure = 700 psig C. HPI Seal Injection flow rate = 28 gpm D. Total Component Cooling flow =554 gpm

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 29 Unit 1 initial conditions:

Reactor power = 100%

Current conditions:

1TE de-energized Based on the above conditions, which ONE of the following describes the status of the listed HPI components?

A. 1B HPI pump de-energized 1HP-26 energized B. 1B HPI pump de-energized 1HP-27 de-energized C. 1C HPI pump de-energized 1HP-26 de-energized D. 1C HPI pump de-energized 1HP-27 energized

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 30 Unit 3 plant conditions:

Reactor power = 100%

Aligning of 3B LPI Train for BWST recirc is in progress Based on the above conditions, which ONE of the following describes a condition that must be met prior to operating 3LP-42 (LPI RETURN TO BWST) in accordance with OP/3/A/1104/004 (Low Pressure Injection System)?

An individual is required to be designated to...

A. close 3LP-42 in the event of an Engineered Safeguards actuation.

B. close 3LP-42 in the event of an LPI piping overpressure condition.

C. throttle 3LP-42 to ensure adequate LPI pump NPSH is maintained.

D. throttle 3LP-42 to ensure LPI pump minimum flow requirements are met.

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 31 Which ONE of the following events and failures will result in fuel/clad damage?

ASSUME NO OPERATOR ACTION A. MSLB with a failure of ES Channels 1 &2 B. MSLB with a failure of ES Channels 3 & 4 C. SBLOCA with a failure of ES Channels 1 &2 D. SBLOCA with a failure of ES Channels 3 &4

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 32 Unit 1 initial conditions:

Loss of all Feedwater HPI forced cooling initiated Quench Tank pressure =50 psig increasing RCS activity indicates no fuel failures present Current conditions:

Quench Tank pressure =3 psig stable Which ONE of the following describes the containment response to the above conditions?

A. RB Normal sump level rises. 1RIA-47 radiation level increases B. RB Normal sump level rises. 1RIA-47 radiation level remains constant C. RB Normal sump level remains constant. 1RIA-47 radiation level increases D. RB Normal sump level remains constant. 1RIA-47 radiation level remains constant

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 33 Which ONE of the following describes the interlock associated with the High Pressure Injection (HPI) valves (HP-1 and HP-2) and Component Cooling (CC) valves (CC-1 and CC-2) for the Letdown Coolers?

The interlock...

A. isolates the Letdown Cooler if letdown temperature reaches interlock setpoint.

B. ensures CC flow is established before letdown flow.

C. prevents over-rating the CC system cooling capacity.

D. ensures letdown flow is secured after CC flow.

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 34 Which ONE of the following states the automatic OPEN setpoints (psig) for 1RC-1 (pzr Spray) and 1RC-66 (PORV) in Mode 1?

1RC-1 1RC-66 A. 2205 2450 B. 2205 2500 C. 2255 2450 D. 2255 2500

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 35 Unit 2 initial conditions:

Reactor power =100%

Feedwater transient occurs Current conditions:

Reactor power = 65%

stable pzr level = 250" slowly decreasing RCS pressure = 2195 psig (highest reached) slowly decreasing pzr temperature =627QF Based on the current conditions, which ONE of the following describes the status of the pzr heaters and the yellow dot on the OAC PIT display?

A. All pzr heaters are "OFF"

/

yellow dot is "0N" the blue saturation line B. All pzr heaters are "OFF"

/

yellow dot is "LEFT" of the blue saturation line C. Some pzr heaters are "ON" / yellow dot is "ON" the blue saturation line D. Some pzr heaters are "ON" / yellow dot is IILEFT" of the blue saturation line

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 36 Unit 2 plant conditions:

Reactor power = 100%

I&E technicians went to the wrong unit and incorrectly removed the HI TEMPERATURE TRIP bistable from the 2B RPS Channel Based on the above conditions, which ONE of the following describes the affect on the Reactor Protection System?

2B RPS Channel is and the associated CRD Breaker.is A. Tripped / Closed B. Tripped / Open C. Not Tripped / Closed D. Not Tripped / Open

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 37 Unit 3 initial conditions:

Reactor power = 100%

38 HPI Pump in service Current conditions:

Reactor tripped due to S8LOCA ES Digital Channels 1, 3, and 5 failed to automatically actuate 8ased on the above conditions, which ONE of the following lists the safety related components that will be in their ES condition?

ASSUME NO OPERATOR ACTIONS A. 3A HPI Pump / 38 LPI Pump

8. 38 HPI Pump / 38 LPI Pump C. 3A HPI Pump / 3A LPI Pump D. 38 HPI Pump / 3A LPI Pump

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 38 Unit 1 initial conditions:

Reactor power = 50%

Current conditions:

LBLOCA occurs 1TC de-energized Based on the above conditions, which ONE of the following describes the status of the below listed Reactor Building Cooling Units five (5) minutes after ES actuates?

ASSUME NO OPERATOR ACTIONS 1A RBCU A. LOW B. LOW C. OFF D. OFF 1B RBCU LOW OFF LOW OFF

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 39 Unit 2 initial conditions:

Reactor Building Spray actuated Current conditions:

RB Pressure = 2 psig slowly decreasing Based on the above conditions, which ONE of the following describes the operation and any control room actions associated with resetting the RB Pressure Contact Buffers and ES Digital Channels 7 &8?

RB Pressure Contact Buffers and ES Digital Channels 7 & 8 A. automatically reset / must be reset manually B. automatically reset / automatically reset C. must be reset manually / must be reset manually D. must be reset manually / automatically reset

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 40 Unit 1 plant conditions:

SB LOCA has occurred EOP Enclosure 5.12 (ECCS Suction Swap to RBES) is in progress 1LP-19 & 1LP-20 (1 A &1B RX BLDG SUCTION) are OPEN 1LP-21 & 1LP-22 (1 A & 1B LPI BWST SUCTION) are OPEN RB pressure = 12 psig stable Based on the above conditions, which ONE of the following describes the suction source that is supplying the RB Spray pumps and the reason for the addition of caustic to the RBES?

A. BWST / to enhance iodine entrainment in RB Spray water B. BWST / to minimize hydrogen production from zirconium-water reaction C. RBES / to enhance iodine entrainment in RB Spray water D. RBES / to minimize hydrogen production from zirconium-water reaction

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 41 Unit 1 initial conditions:

Reactor Power = 100%

stable 1RIA-16 =14 mr/hr increasing 1RIA-17 =0.01 mr/hr stable 1RIA-59 = 12 gpm slowly increasing 1RIA-60 =5.8 E -3 gpd stable 1RIA-40 in alarm HIGH Current conditions:

Reactor power =45%

decreasing 1SA-8/E-1 0 "RM N-16 Primary to Secondary Tube Leak" actuated 1RIA-16 =21 mr/hr increasing 1RIA-17 =3.7 mr/hr increasing 1RIA-59 = 27.1 gpm increasing 1RIA-60 = 1.9 gpm increasing Based on the current conditions above, which ONE of the following describes the SG(s) with indications of a tube leak and the procedure that contains the required operator actions used to mitigate this event?

A. 1A SG ONLY / AP/31 (Primary to Secondary Leakage)

B. 1A SG ONLY / EOP SGTR Tab C. 1A & 1B SG / AP/31 (Primary to Secondary Leakage)

D. 1A & 1B SG / EOP SGTR Tab

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 42 Unit 2 initial conditions:

Reactor power =100%

Current conditions:

Feedwater Valve i1P controlling signal fails LOW ASSUME NO OPERATOR ACTIONS Based on the above conditions, which ONE of the following describes the Main Feedwater Pump Turbines (FWPTs) response and the required actions per AP/28 (ICS Instrument Failures)?

BOTH FWPTs speed

/ Place A. increases to HSS (high speed stop) / BOTH 2A &2B MAIN FDW PUMPs to Hand and lower speed to prevent tripping FWPs on high discharge pressure B. decreases to LSS (low speed stop) / BOTH 2A &2B MAIN FDW PUMPs to Hand and raise speed to prevent tripping the Reactor on high RCS pressure C. increases to HSS (high speed stop) / ALL Feedwater Control Valves (Main &

Startup) to Hand and adjust as necessary to restore stable plant conditions D. decreases to LSS (low speed stop) / ALL Feedwater Control Valves (Main &

Startup) to Hand and adjust as necessary to restore stable plant conditions

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 43 Unit 3 initial conditions:

04:00:00 Reactor power =70%

stable 3A Main Feed Pump suction pressure = 236 psig decreasing Current conditions:

04:01 :25 3A Main FDW Pump suction pressure =230 psig increasing Based on the current conditions, which ONE of the following describes the current status of the Main Feedwater pumps and the plant?

A. Both MFPs are operating / Plant runback in progress at 200/0/min B. Both MFPs are operating / Reactor power =70%

stable C. 3A MFP has tripped / Plant runback in progress at 200/0/min D. 3A MFP has tripped / Reactor power =65%

stable

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 44 Unit 1 initial conditions:

Reactor power = 100%

1TDEFWP is OOS Current conditions:

Both Main Feed Pumps trip 1A MDEFWP fails to start 1A SG level = 26 inches XSUR decreasing 1B SG level = 28 inches XSUR increasing

  • .9 (Extended EFDW Operation) is in progress 1FDW-313 and 1FDW-314 (1A & 1B EFDW LINE DISCH X-CONNs) open Based on the above conditions, which ONE of the following describes the maximum acceptable flowrate (gpm) allowed to each SG at the same time per EOP Rule 7?

A. 1A SG = 300 / 1B SG = 300 B. 1A SG =500 / 1B SG =450

c. 1A SG = 600 / 1B SG = 600 D. 1A SG = 100 / 1B SG = 600

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 45 Unit 1 plant conditions:

Reactor power = 100%

Pressurizer level =219 inches and stable 1B1 RCP parameters:

Lower seal cavity pressure = 900 psig decreasing Upper seal cavity pressure = 100 psig decreasing Seal Return flow = 1.1 gpm decreasing Seal Leakage flow = 0.9 gpm increasing Based on the above conditions, which ONE of the following 1B1 Rep seal(s) are failing?

A. Lower ONLY B. Upper ONLY C. BOTH Lower and Upper D. BOTH Middle and Upper

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 46 Unit 1 initial conditions:

Reactor power = 22%

power CT1 Amps = 2000 Central Switchyard is energizing the STBY Buses PCB 17 (OCONEE WHo STARTUP TRANS. CT1 TIE) is open for maintenance Current conditions:

Yellow Bus lockout occurs Based on the conditions above, which ONE of the following alignments will supply power to Unit 1's Main Feeder Buses?

A. 1T (Unit 1 Auxiliary Transformer)

B. CT-1 (Unit 1 Startup Transformer)

C. CT-4 (Keowee Underground to STBY Buses Transformer)

D. CT-5 (100KV line to STBY Buses)

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 47 Initial conditions:

Both Keowee Units generating to the grid at ~ 60 MWe ACB-4 closed Current conditions:

A SBLOCA occurs on Unit 2 When ES channels 1&2 actuate

- Keowee Unit #2 Emergency locks out

- Keowee Main Step-Up Transformer locks out Within thirty (30) seconds of these actions, which ONE of the following Keowee breaker combinations should exist?

A. ACB-1 open and ACB-2 closed B. ACB-1 closed and ACB-3 closed C. ACB-3 open and ACB-4 closed D. ACB-3 closed and ACB-4 open

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 48 Station initial conditions:

All three units Reactor power = 100 Current conditions:

All Unit's 4160v Main Feeder Busses are de-energized Unit 1, 2, and 3 EOP Blackout tabs in progress Based on the above conditions, which ONE of the following describes the required status of Unit 1 Essential Inverters per the EOP Enclosure 5.38 (Restoration of Power) and why?

Unit 1's Essential Inverters...

A. remain energized to provide power to ES channels.

B. remain energized to provide control power to 4160v.

C. are de-energized to prevent inverter damage.

D. are de-energized to extend available battery life.

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 49 Operators are preparing to synchronize KHU-2 to the grid per OP/O/A/11 06/019, Keowee Hydro At Oconee The operator notes the following indications:

Keowee 2 Line Volts = 13.8 kV Keowee 2 Output Volts = 15.4 kV Grid Frequency =60 cycles Keowee Frequency = 60.6 cycles Based on the above conditions, which one of the following describes the control that will be used to adjust the synchroscope indication and what is the response when ACB 2 is closed?

The will be used to adjust the synchroscope indication and A. UNIT 2 AUTO VOLTAGE ADJUSTER 1 ACB 2 will NOT receive a trip signal as a direct result of the line voltage differential.

B. UNIT 2 SPEED CHANGER MOTOR 1 after 5 seconds ACB 2 will receive a trip signal as a direct result of the line voltage differential C. UNIT 2 AUTO VOLTAGE ADJUSTER 1 after 5 seconds ACB 2 will receive a trip signal as a direct result of the line voltage differential D. UNIT 2 SPEED CHANGER MOTOR 1 ACB 2 will NOT receive a trip signal as a direct result of the line voltage differential

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 50 Which ONE of the following describes the operation of the Unit Vent Radiation Monitors RIA-45 and RIA-46 when the switchover acceptance range setpoint is reached?

RIA-45 will read and RIA-46 will provide A. offscale high

/ only alarm and unit vent radiation level indication.

B. offscale high / the same interlock functions that RIA-45 performs.

C. ZERO / only alarm and unit vent radiation level indication.

D. ZERO / the same interlock functions that RIA-45 performs.

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 51 Unit 1 initial conditions:

Reactor power =100 Current conditions:

A, B, and C LPSW pumps tripped AP/24, Loss of LPSW in progress Based on the above conditions, which ONE of the following conditions will result in EOP entry?

A. Pressurizer level =278 inches B. Anyone CRD stator temperature = 192 QF C. Any RCP Motor Stator temperature =265 QF D. Main Turbine journal bearing #9 vibration = 17 mils

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 52 Unit 3 initial conditions:

Reactor Power = 100%

3A LPSW Pump operating LPSW Line leak occurs Current conditions:

Unit 3 LPSW Pressure = 60 psig decreasing slowly Operating LPSW pump(s) amps slowly increasing Based on the conditions above, which ONE of the following describes the status of the Unit 3 LPSW Pumps and an appropriate action per AP/24 (Loss of LPSW)?

A. ONLY 3A LPSW pump is running / secure operating LPSW pump B. ONLY 3A LPSW pump is running / reduce LPSW loads as needed C. BOTH 3A and 3B LPSW pumps are running / reduce LPSW loads as needed D. BOTH 3A and 3B LPSW pumps are running / secure operating LPSW pumps

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 53 Initial conditions:

IA Pressure = 105 psig stable IA-2718 (Air Supply to Radwaste Facility) Open Radwaste Air pressure 78 psig (and stable)

Instrument air compressors are aligned as follows:

Primary IA compressor is Operating Backup IA compressors "A" and "B" in Standby 1 Backup IA compressor "C" in Standby 2 Auxiliary IA compressors in Auto Current conditions:

IA pressure decreased to 91 psig and is stable Based on the conditions above, which ONE of the following describes the status of IA components?

A. Only Auxiliary IA Compressors start B. Only Backup IA compressors "A" & "B" start

c. ALL Backup IA compressors start; Auxiliary IA Compressors start D. ALL Backup IA compressors start; IA-2718 (Air Supply to Radwaste Facility)

CLOSES

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 54 Unit 2 plant conditions:

Reactor power = 100%

RB pressure = 12.3 psia Based on the above conditions, which ONE of the following describes how RB pressure will be increased to within the limits per PT/2/A/0600/001 (Periodic Instrument Surveillance)?

A. 2PR-42 (RB Purge Disch to Unit Vent) will be opened and this alignment is limited to 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.

B. 2PR-42 (RB Purge Disch to Unit Vent) will be opened and this alignment is limited to 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.

C. 21A-90 (IA Pent Isolation) will be opened and this alignment is limited to 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.

D. 21A-90 (IA Pent Isolation) will be opened and this alignment is limited to 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 55 Unit 1 initial conditions:

Reactor Power = 1000/0 Reactor Building average temperature = 120°F stable RBCU Status:

1A - High Speed 1B - High Speed 1C - High Speed Current conditions:

Inadvertent ES Channel 5 actuation Based on the conditions above, which ONE of the following describes the response of RB Pressure and the RB high pressure limit per TS 3.6.4 (Containment Pressure)?

RB Pressure will and the RB high pressure TS Limit is A. increase /

5 + 1.2 psig B. increase /
5 + 2.45 psig
c. decrease /
5 + 1.2 psig D. decrease /
5 + 2.45 psig

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 56 Unit 1 initial conditions:

RCS Cooldown is in progress RCS temperature =240°F RCS pressure = 260 psig PORV Setpoint Selector is in LOW RC LR PRESS ENABLE Switch is inadvertently placed in OFF Current conditions:

RCS pressure = 450 psig Based on the conditions given, which ONE of the following describes the operation of the PORV?

A. PORV will open if pressure reaches 2450 psig.

B. PORV will open if the LR PRESS ENABLE Switch is placed back in ON.

C. PORV will NOT open automatically OR manually D. PORV will NOT open automatically but can be opened manually

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 57 Unit 1 Power Range NI indications are as follows:

NI-5 = 98.7%

NI-6 = 99.2%

NI-7 = 99.3%

NI-8 = 98.8%

NI-9 = 99.1 %

Based on the conditions above, which ONE of the following NI signals will be supplying the input to the Unit 1 Chessell NI Chart Recorder?

A. NI-5 B. NI-6 C. NI-7 D. NI-9

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 58 Unit 1 initial conditions:

Reactor power = 40%

Current conditions:

Final Feedwater temperature controlling signal fails HIGH Based on the conditions above, which ONE of the following describes the initial plant response and the appropriate ICS station(s) used to stabilize the plant in accordance with AP/28 (ICS Instrument Failures)?

Actual Feedwater Flow will __. Place the Diamond Panel in Manual and in Hand.

A. decrease / 1A & 1B FDW Masters B. decrease / Steam Generator Master C. increase / 1A & 1B FDW Masters D. increase / Steam Generator Master

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 59 Which ONE of the following describes the Train A ICCM/RVLIS plasma display indication of CORE SCM for a superheated core and the Core Exit Thermocouples used to calculate this indication.

A. Reverse video with negative numbers I Average of the 5 highest of the 12 for that train of ICCM B. Red flashing negative numbers I Average of the 5 highest of the 12 for that train of ICCM C. Reverse video with negative numbers I Average of the 5 highest of the 24 qualified D. Red flashing negative numbers I Average of the 5 highest of the 24 qualified

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 60 Unit 1 initial conditions:

Reactor power = 100%

1KI is de-energized Current conditions:

Reactor trip Based on the conditions given, which ONE of the following describes the operation of the Turbine Bypass valves (TBVs)?

The TBVs...

A. fail closed.

B. fail to 50%

open.

C. will continue to function normally in Auto.

D. will be controlled manually from the control room.

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 61 Unit 1 initial conditions:

Mode 6 Defueling in progress 1RIA-6 (Spent Fuel Pool Area Monitor) =4 mr/hr stable Current conditions:

1RIA-6 monitor power supply fuse blows 1RIA-6 local reading = 0 mr/hr 1RIA-6 View Node indication is magenta Based on the conditions above, which ONE of the following describes the impact on fuel handling activities per OP/1/A/1502/007 (Operations Defueling/Refueling Responsibilities)?

Fuel Handling activities in the SFP may...

A. NOT continue until a replacement monitor is in place that is equivalent to 1RIA-6.

B. continue because only the SFP Portable Bridge monitor is required.

C. NOT continue until continuous RP coverage is present on the SFP Bridge.

D. continue provided RIA-41 (SFP Gas) is operable.

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 62 Unit 1 initial conditions:

Mode 6 Current conditions:

FTC Level = 20.9 ft (placard on FTC Wall) decreasing East fuel carriage is in the RB and empty West fuel carriage is in the SFP and empty Main Fuel Bridge in transit to the upender with a spent fuel assembly in the mast Section 40 (Fuel Transfer Canal Flooded) of AP/26 (Loss of Decay Heat Removal) initiated Based on the conditions above, which ONE of the following describes the first actions required to be taken in accordance with Section 40 (Fuel Transfer Canal Flooded)?

A. Place the fuel assembly into the East Upender and position the West Fuel Carriage to the RB B. Place the fuel assembly into the East Upender and position the East Fuel Carriage to the SFP C. Verify SF system aligned for refueling cooling mode and stop 2B SF cooling pump D. Close 1SF-1 and 1SF-2 (EastlWest Transfer Tube Isolations)

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 63 Unit 2 initial conditions:

Reactor power = 100%

stable Generator MWe = 890 Mwe Condenser vacuum = 28.5 inches Hg stable Current conditions:

Condenser vacuum = 24.5 inches Hg slowly decreasing AP-27 (Loss of Condenser Vacuum) in progress Based on the conditions above, which ONE of the following describes the impact on Reactor power and a required action in accordance with AP/27?

Reactor power wilL..

A. decrease / reduce power to decrease turbine exhaust steam load on condenser B. decrease / start and align the Main Vacuum Pumps to increase vacuum in the condenser C. remains approximately the same / reduce power to decrease turbine exhaust steam load on condenser D. remains approximately the same / start and align the Main Vacuum Pumps to increase vacuum in the condenser

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 64 Which ONE of the following describes the RIA status that will automatically terminate a Gaseous waste release on Unit 3 and the status of the Waste Gas Exhauster if it is running prior to the alarm?

A. 3RIA-37 (NORM WD Gas) AND 3RIA-38 (HIGH WD Gas) HIGH alarm actuated /

Waste Gas Exhauster stops automatically.

B. 3RIA-37 (NORM WD Gas) OR 3RIA-38 (HIGH WD Gas) HIGH alarm actuated /

Waste Gas Exhauster stops automatically.

C. 3RIA-37 (NORM WD Gas) AND 3RIA-38 (HIGH WD Gas) HIGH alarm actuated /

operator must manually stop the Waste Gas Exhauster.

D. 3RIA-37 (NORM WD Gas) OR 3RIA-38 (HIGH WD Gas) HIGH alarm actuated /

operator must manually stop the Waste Gas Exhauster.

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 65 Unit 2 initial conditions:

Reactor power =100 Switchyard Isolate occurs Current conditions:

Unit 2 MFB 1 & 2 energized Based on the conditions above, which ONE of the following describes the suction supply to LPSW and when the LPSW pumps will restart?

Unit 1 &2 LPSW is supplied via the ECCW and LPSW pumps will restart

____ after power is restored?

A. first siphon

/ immediately B. second siphon

/ immediately C. first siphon

/ 10 seconds D. second siphon

/ 10 seconds

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 66 Which ONE of the following describes the requirements in OMP 1-02, Rules of Practice to ensure a Motor Operated Valve that acts as a throttle valve closes?

The switch must be placed in the CLOSED position and...

A. released when the OPEN indication light is off.

B. released as soon as the CLOSED indication light is lit.

C. held for a minimum of five seconds after the CLOSED indication light is lit.

D. held for a minimum of three seconds after.the CLOSED indication light is lit.

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 67 Unit 3 plant conditions:

Time: 0340 Night Shift RO makes an AUTOLOG entry Time: 0905 Day Shift RO reviewing the AUTOLOG identifies a mistake in the entry made at 0340 Based on the above conditions, which ONE of the following describes how the AUTOLOG entry is corrected per OMP 2-2 (Unit Logs)?

Unit AUTOLOG corrections may be made...

A. ONLY by the CR SRO by editing the original-entry.

B. by any member of the CR Team by editing the original entry.

C. ONLY by the CR SRO by making a late entry that references the original entry.

D. by any member of the CR Team by making a late entry that references the original entry.

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 68 Which ONE of the following activities is consistent with the conservative operating guidance contained in SOMP 1-2 (Reactivity Management)?

A. Manual rod withdrawal during a Feedwater transient to stop a temperature decrease caused by an instrument failure B. Manually increasing Feedwater flow to stop an RCS pressure increase caused by an RCS temperature increase C. Manually raising one Loop FDW demand while lowering the other Loop FDW demand to controll1Tcold following an RCP trip D. Manually increasing turbine demand to reduce Turbine Header Pressure and RCS temperature

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 69 In accordance with OMP 1-02 (Rules of Practice), which ONE of the following describes a condition which would allow Independent Verification of a single valve to be waived and the minimum level of approval required?

A. Dose received will be =14 mr for a single check Plant SRO B. Valve located in a room where the area dose rate = 878 mr/hr Plant SRO C. Dose received will be = 14 mr for a single check Operations Superintendent D. Valve located in a room where the area dose rate = 878 mr/hr Operations Superintendent

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 70 Which ONE of the following describes two (2) evolutions or tests that have pre-planned pre-job briefs per NSD 213 (Risk Management Process), Infrequently Performed Tests or Evolutions?

A. Unit 2 Mid-Loop Operations / Turbine Stop Valve Movement Test B. Unit 2 Mid-Loop Operations / Zero Power Physics Testing C. Placing a new demineralizer in service / Turbine Stop Valve Movement Test D. Placing a new demineralizer in service / Zero Power Physics Testing

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 71 Unit 3 plant conditions:

Spent Fuel Demineralizer Room dose rate =3000 MR/HR Based on the above condition, which ONE of the following describes the radiological posting requirements and the access controls for this area?

A. Locked High Radiation / area MUST be posted with a Yellow Flashing Light B. Locked High Radiation / entrance MUST be Locked or Guarded C. Very High Radiation / area MUST be posted with a Yellow Flashing Light D. Very High Radiation / entrance MUST be Locked or Guarded

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 72 Unit 1 plant conditions:

Reactor power = 100%

7 gpm primary to secondary leak in 1A SG AP/31 is in progress The SRO has directed the NEO to perform an action in the turbine building basement Based on the above conditions, which ONE of the following describes the location that will have the greatest increase in general area dose rates and the operators response if he receives a dose alarm in the area?

A. Powdex / Remain in the area and monitor dose B. Powdex / Immediately stop and leave the area C. TB Sump / Remain in the area and monitor dose D. TB Sump / Immediately stop and leave the area

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 73 Plant conditions:

All Units Reactor power =100%

1SA3/B-6 (Fire Alarm) actuated NEO reports flames and heavy smoke spreading to equipment and cable trays Fire location =Near the LPSW pumps, Column G30 Based on the above information, which ONE of the following locations is the affected SSF Risk Area(s) and the required action?

REFERENCE PROVIDED A. ALL Three Units / Trip ALL Three Units B. Unit 2 ONLY / Trip Unit 2 ONLY

c. ALL Three Units / Perform a controlled shutdown on all three units D. Unit 2 ONLY / Perform a controlled shutdown on Unit 2 ONLY

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 74 Unit 1 plant conditions:

Reactor tripped from 100%

power The following Statalarms actuate:

1SA-1/C-11 (ES Channel 7 Trip) 1SA-1 /0-11 (ES Channel 8 Trip) 1SA-2/C-4 (RC Pressurizer Level Emerg High/Low) 1SA-2/C-8 (AFIS Header A Initiated) 1SA-2/0-5 (HP LOST Level Interlock Initiated) 1SA-8/A-3 (FOWPT A Trip) 1SA-8/A-6 (FOWPT B Trip)

Based on the above conditions, which ONE of the following emergency procedures has the highest priority?

A. Enclosure 5.1 (ES Actuation)

B. Rule 5 (Main Steam Line Break)

C. Enclosure 5.5 (pzr and LOST Level Control)

O. Rule 3 (Loss of Main or Emergency Feedwater)

2009 NRC REACTOR OPERATOR EXAM 1 POINT Question 75 Unit 3 plant conditions LDST level =75 inches decreasing LDST pressure =35 psig stable Based on the above level and pressure trend, which ONE of the following describes the status of the HPI system and states the required action in accordance with OP/1108/001 (Curves and General Information)?

REFERENCE PROVIDED HPI is...

A. Operable 1 Initiate makeup to LDST B. Operable 1Depressurize LDST C. Inoperable 1 Initiate makeup to LDST D. Inoperable 1 Depressurize LDST