Summary of Preliminary Findings from the USGS/PG&E hazard studies for the Central Coastal California Region Seismicity data from the USGS: J. Hardebeck, Areo-magnetic data from V. Langenheim, Marine-magnetic data from J. Watt

Regional Seismicity Based on Local Velocity Model Double-difference Tomography (tomoDD):

- solves jointly for velocity model and earthquake locations

- absolute and relative arrival times

- improves both absolute and relative earthquake locations Earthquake Data:

- ~1400 earthquakes (exclude San Simeon aftershocks)

- ~26,000 P-wave and ~3000 S-wave absolute arrival times

- ~11,000 P-wave and ~5000 S-wave relative arrival times from waveform cross-correlation

Focal Mechanisms Ray tracing in 3D velocity model.

Black: good quality (A-C of Hardebeck & Shearer) single-event mechanisms.

G l

lit i

l t

Grey: lower quality single-event mechanisms, checked for reasonableness.

Red: composite mechanisms.

DCPP

Seismicity Comparison with raw (unprocessed) aeromagnetic data

Seismicity Comparison with raw (unprocessed) Marine Magnetic Data