IR 05000020/2008203

From kanterella
(Redirected from ML083240145)
Jump to navigation Jump to search
IR 05000020-08-203, on 11/03/2008 Through 11/06/2008, Massachusetts Institute of Technology (Mit)
ML083240145
Person / Time
Site: MIT Nuclear Research Reactor
Issue date: 12/01/2008
From: Johnny Eads
Research and Test Reactors Branch B
To: Bernard J
Massachusetts Institute of Technology (MIT)
Voth M, NRR/ADRA/DPR/PRT, 415-1210
References
IR-08-203
Download: ML083240145 (17)


Text

ber 1, 2008

SUBJECT:

NRC INSPECTION REPORT NO. 50-020/2008-203

Dear Dr. Bernard:

This letter refers to the inspection conducted on November 3 through 6, 2008, at your research reactor facility. The inspection included a review of activities authorized for your facility. The enclosed report presents the results of that inspection.

Areas examined during the inspection are identified in the report. Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations of activities in progress. Based on the results of this inspection, no safety concern or noncompliance with NRC requirements was identified. No response to this letter is required.

In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRCs document system (ADAMS). ADAMS is accessible from the NRC Web site at (the Public Electronic Reading Room) http://www.nrc.gov/reading-rm/adams.html.

If you have any questions concerning this inspection, please contact Marcus H. Voth at 301-415-1210.

Sincerely,

/RA/

Johnny H. Eads, Branch Chief Research and Test Reactors Branch B Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No.: 50-020 License No.: R-37 Enclosure: NRC Inspection Report No. 50-020/2008-203 cc: See next page

Massachusetts Institute of Technology Docket No. 50-20 cc:

City Manager City Hall Cambridge, MA 02139 Department of Environmental Protection One Winter Street Boston, MA 02108 Director Radiation Control Program Department of Public Health 90 Washington Street Dorchester, MA 02121 Nuclear Preparedness Manager Massachusetts Emergency Management Agency 400 Worcester Road Framingham, MA 01702-5399 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611

December 1, 2008 Dr. John