Farley Inspection / Activity Plan 09/01/2008 - 12/31/2009 Inspection Type Inspection Activity Planned Dates Start End No. of Staff on Site Title Unit Number Page 1 of 2 09/02/2008 17:49:49 Report 22 2

PB2TI176

- EMERGENCY DIESEL GENERATOR MARGIN Generic Safety Inspectio Emergency Diesel Generator Tech Spec Surveillance Requirements Re: Endurance & Margin Testing 07/07/2008 09/30/2008 1, 2 2515/176 IP 1

PSB1-EP

- EVENT FOLLOW-UP Baseline Inspections Followup of Events and Notices of Enforcement Discretion 08/19/2008 09/05/2008 1, 2 71153 IP 1

PB2-SUP

- EMERGENCY DIESEL GENERATOR EXHAUST VIO Supplemental Program Supplemental Inspection For One Or Two White Inputs In A Strategic Performance Area 09/22/2008 09/26/2008 1

95001 IP 4

OL EXAM

- INITIAL EXAM PREP Not Applicable FARLEY/NOVEMBER 2008 EXAM AT POWER FACILITIES 09/29/2008 10/03/2008 1

V23288 2

PSB1-RP

- RADIATION PROTECTION OCCUPATIONAL WK1 Baseline Inspections Access Control to Radiologically Significant Areas 10/20/2008 10/24/2008 1, 2 7112101 IP Baseline Inspections ALARA Planning and Controls 10/20/2008 10/24/2008 1, 2 7112102 IP Baseline Inspections Radioactive Material Processing and Transportation 10/20/2008 10/24/2008 1, 2 7112202 IP Baseline Inspections Occupational Exposure Control Effectiveness 10/20/2008 10/24/2008 1, 2 71151-OR01 IP Baseline Inspections RETS/ODCM Radiological Effluent 10/20/2008 10/24/2008 1, 2 71151-PR01 IP 1

EB3-ISI

- UNIT 2 - INSERVICE INSPECTION Baseline Inspections Inservice Inspection Activities - PWR 10/27/2008 10/31/2008 2

7111108P IP 4

OL EXAM

- INITIAL EXAM - WEEK 1 Not Applicable FARLEY/NOVEMBER 2008 EXAM AT POWER FACILITIES 10/27/2008 10/31/2008 1

V23288 4

OL EXAM

- INITIAL EXAM - WEEK 2 Not Applicable FARLEY/NOVEMBER 2008 EXAM AT POWER FACILITIES 11/03/2008 11/07/2008 1

V23288 2

PSB1-RP

- RADIATION PROTECTION OCCUPATIONAL WK2 Baseline Inspections Access Control to Radiologically Significant Areas 11/03/2008 11/07/2008 1, 2 7112101 IP Baseline Inspections ALARA Planning and Controls 11/03/2008 11/07/2008 1, 2 7112102 IP Baseline Inspections Radioactive Material Processing and Transportation 11/03/2008 11/07/2008 1, 2 7112202 IP Baseline Inspections Occupational Exposure Control Effectiveness 11/03/2008 11/07/2008 1, 2 71151-OR01 IP Baseline Inspections RETS/ODCM Radiological Effluent 11/03/2008 11/07/2008 1, 2 71151-PR01 IP 1

EB3TI172

- REACTOR COOLANT SYSTEM DISSIMILIAR METAL Generic Safety Inspectio Reactor Coolant System Dissimiliar Metal Butt Welds 11/17/2008 11/21/2008 1, 2 2515/172 IP 5

EB7-PIR

- PROBLEM IDENTIFICATION AND RESOLUTION Baseline Inspections Identification and Resolution of Problems 12/01/2008 12/05/2008 1, 2 71152B IP Baseline Inspections Identification and Resolution of Problems 12/15/2008 12/19/2008 1, 2 71152B IP 2

EB3-HS

- HEAT SINK Baseline Inspections Heat Sink Performance 12/01/2008 12/05/2008 1, 2 7111107B IP 3

PB2TI171

- B.5.B PHASE 2&3 Generic Safety Inspectio Verification of Site Specific Implementation Of B.5.b Phase 2 & 3 Mitigating Strategies 12/08/2008 12/12/2008 1, 2 2515/171 IP This report does not include INPO and OUTAGE activities.

This report shows only on-site and announced inspection procedures.

Farley Inspection / Activity Plan 09/01/2008 - 12/31/2009 Inspection Type Inspection Activity Planned Dates Start End No. of Staff on Site Title Unit Number Page 2 of 2 09/02/2008 17:49:49 Report 22 10 EB1-CDBI

- COMPONENT DESIGN BASIS INSPECTION Baseline Inspections Component Design Bases Inspection 01/12/2009 01/16/2009 1, 2 7111121 IP Baseline Inspections Component Design Bases Inspection 01/26/2009 01/30/2009 1, 2 7111121 IP Baseline Inspections Component Design Bases Inspection 02/09/2009 02/13/2009 1, 2 7111121 IP Baseline Inspections Component Design Bases Inspection 02/23/2009 02/27/2009 1, 2 7111121 IP 2

EB3-ISI

- UNIT 1 INSERVICE INSPECTION Baseline Inspections Inservice Inspection Activities - PWR 04/06/2009 04/10/2009 1

7111108P IP 1

EB3TI172

- REACTOR COOLANT SYSTEM DISSIMILIAR METAL Generic Safety Inspectio Reactor Coolant System Dissimiliar Metal Butt Welds 04/06/2009 04/10/2009 1

2515/172 IP 1

PSB1-RP

- RADIATION PROTECTION ACCESS (OUTAGE)

Other Routine Operation of an Independent Spent Fuel Storage Installation at Operating Plants 04/13/2009 04/17/2009 1, 2 60855.1 IP Baseline Inspections Access Control to Radiologically Significant Areas 04/13/2009 04/17/2009 1, 2 7112101 IP Baseline Inspections Occupational Exposure Control Effectiveness 04/13/2009 04/17/2009 1, 2 71151-OR01 IP 3

PSB1-RP

- RADIATION PROTECTION PUBLIC CORNERSTONE Baseline Inspections Radiation Monitoring Instrumentation and Protective Equipment 08/10/2009 08/14/2009 1, 2 7112103 IP Baseline Inspections Radioactive Gaseous and Liquid Effluent Treatment and Monitoring Systems 08/10/2009 08/14/2009 1, 2 7112201 IP Baseline Inspections Radiological Environmental Monitoring Program (REMP) And Radioactive Material Control Program 08/10/2009 08/14/2009 1, 2 7112203 IP 1

PSB1-EP

- EMERGENCY PREPAREDNESS INSPECTION Baseline Inspections Emergency Response Organization, Drill/Exercise Performance Indicator, Program Review 09/07/2009 09/11/2009 1, 2 2515/175 IP EP Baseline Inspection Alert and Notification System Testing 09/07/2009 09/11/2009 1, 2 7111402 IP EP Baseline Inspection Emergency Response Organization Augmentation Testing 09/07/2009 09/11/2009 1, 2 7111403 IP EP Baseline Inspection Emergency Action Level and Emergency Plan Changes 09/07/2009 09/11/2009 1, 2 7111404 IP EP Baseline Inspection Correction of Emergency Preparedness Weaknesses and Deficiencies 09/07/2009 09/11/2009 1, 2 7111405 IP Baseline Inspections Drill/Exercise Performance 09/07/2009 09/11/2009 1, 2 71151-EP01 IP Baseline Inspections ERO Drill Participation 09/07/2009 09/11/2009 1, 2 71151-EP02 IP Baseline Inspections Alert & Notification System 09/07/2009 09/11/2009 1, 2 71151-EP03 IP 5

PB7-PIR

- PROBLEM IDENTIFICATION AND RESOLUTION Baseline Inspections Identification and Resolution of Problems 11/02/2009 11/06/2009 1

71152B IP Baseline Inspections Identification and Resolution of Problems 11/16/2009 11/20/2009 1

71152B IP 3

OL EXAM

- INITIAL EXAM PREP Not Applicable FARLEY/NOVEMBER 2009 EXAM AT POWER FACILITIES 11/02/2009 11/06/2009 1

V23323 3

OL EXAM

- INITIAL EXAM - WEEK 1 Not Applicable FARLEY/NOVEMBER 2009 EXAM AT POWER FACILITIES 11/16/2009 11/20/2009 1

V23323 3

OL EXAM

- INITIAL EXAM - WEEK 2 Not Applicable FARLEY/NOVEMBER 2009 EXAM AT POWER FACILITIES 11/30/2009 12/04/2009 1

V23323 This report does not include INPO and OUTAGE activities.

This report shows only on-site and announced inspection procedures.