Other: CNRO-2007-00036, Updated Schedule for Submittal of Future License Renewal Applications for Entergy Plants, L-08-123, Drawing Lr 1-46-2, Rev. 5, Post DBA Hydrogen Analyzer System, ML080840484, ML080880015, ML081000332, ML081260535, ML081270036, W3F1-2008-0021, RAI Response to Amendment Request NPF-38-271 to Support Next Generation Fuel
|
MONTHYEARW3F1-2007-0037, License Amendment Request NPF-38-271 to Support Next Generation Fuel2007-08-0202 August 2007 License Amendment Request NPF-38-271 to Support Next Generation Fuel Project stage: Request W3F1-2007-0038, Emergency Core Cooling System Performance Analysis2007-08-0909 August 2007 Emergency Core Cooling System Performance Analysis Project stage: Request W3F1-2007-0045, Supplement to the ECCS Performance Analysis Submittal in Support of Next Generation Fuel - 1999 EM Optional Steam Cooling Model Justification2007-10-0404 October 2007 Supplement to the ECCS Performance Analysis Submittal in Support of Next Generation Fuel - 1999 EM Optional Steam Cooling Model Justification Project stage: Request CNRO-2007-00036, Updated Schedule for Submittal of Future License Renewal Applications for Entergy Plants2007-10-0404 October 2007 Updated Schedule for Submittal of Future License Renewal Applications for Entergy Plants Project stage: Other W3F1-2008-0004, Supplement to Amendment Request NPF-38-271 to Support Next Generation Fuel2008-01-17017 January 2008 Supplement to Amendment Request NPF-38-271 to Support Next Generation Fuel Project stage: Supplement ML0801701872008-01-17017 January 2008 Waterfor 3-2007-11-DRAFT Written Exam Review Project stage: Request W3F1-2008-0005, Request for Additional Information Related to Emergency Cooling System Performance Analysis2008-01-21021 January 2008 Request for Additional Information Related to Emergency Cooling System Performance Analysis Project stage: Request ML0801802842008-01-22022 January 2008 Request for Additional Information on the Revised Emergency Core Cooling System Performance Analysis Supporting the Next Generation Fuel Project stage: RAI ML0801600592008-02-0707 February 2008 Request for Additional Information Regarding Review of Supplemental Information to ECCS Performance Analysis in Support of Next Generation Fuel, Optional Spacer Grid Steam Cooling Transfer Model Project stage: RAI ML0803804332008-02-12012 February 2008 Request for Additional Information License Amendment Request to Modify TS 6.9.1.11.1, Core Operating Limits, TS 3.5.1, Safety Injection Tanks, & TS 3.6.1.5, Containment Air Temperature to Support Next Generation Fuel Project stage: RAI W3F1-2008-0006, RAI Response to Supplement to ECCS Performance Analysis Submittal in Support of Next Generation Fuel in Waterford 3 - 1999 EM Optional Steam Cooling Model Justification2008-03-0404 March 2008 RAI Response to Supplement to ECCS Performance Analysis Submittal in Support of Next Generation Fuel in Waterford 3 - 1999 EM Optional Steam Cooling Model Justification Project stage: Request W3F1-2008-0021, RAI Response to Amendment Request NPF-38-271 to Support Next Generation Fuel2008-03-10010 March 2008 RAI Response to Amendment Request NPF-38-271 to Support Next Generation Fuel Project stage: Other ML0808404842008-03-24024 March 2008 E-mail from Ronald L. Williams, Entergy, to N. Kalyanam, NRC, RAI Response to On-Going Processes to Support Next Generation Fuel Project stage: Other ML0810003322008-04-0303 April 2008 Drawing Lr 1-30-1, Rev. 5, River Water System Project stage: Other L-08-123, Drawing Lr 1-46-2, Rev. 5, Post DBA Hydrogen Analyzer System2008-04-0303 April 2008 Drawing Lr 1-46-2, Rev. 5, Post DBA Hydrogen Analyzer System Project stage: Other ML0808800142008-04-15015 April 2008 License Amendment 214, Request to Support Next Generation Fuel; Review and Approval of ECCS Performance Analysis; and Review and Approval of Supplement to ECCS Performance Analysis Project stage: Approval ML0808800152008-04-15015 April 2008 Tech Spec Pages for Amendment 214, Request to Support Next Generation Fuel; Review and Approval of ECCS Performance Analysis; and Review and Approval of Supplement to ECCS Performance Analysis Project stage: Other ML0812700362008-05-0909 May 2008 Tech Spec Page for Correction to Amendment 214 Request to Support Next Generation Fuel; Review & Approval of Revised ECCS Performance Analysis; & Review & Approval of Supplement to ECCS Performance Analysis Project stage: Other ML0812605352008-05-0909 May 2008 Correction to Amendment 214 Request to Support Next Generation Fuel; Review & Approval of Revised ECCS Performance Analysis; & Review & Approval of Supplement to ECCS Performance Analysis (Tac Nos. MD6299, MD6363, & MD6954) Project stage: Other ML21148A0522021-06-0808 June 2021 Correction to License Amendment 214 Request to Support Next Generation Fuel; Review and Approval of Revised ECCS Performance Analysis; and Review and Approval of Supplement to the ECCS Performance Analysis Project stage: Approval 2008-02-07
[Table View] |
Text
WATERFORD - UNIT 3 3/4 6-13 AMENDMENT NO. 199,
CONTAINMENT SYSTEMS AIR TEMPERATURE LIMITING CONDITION FOR OPERATION 3.6.1.5 Primary containment average air temperature shall be > 95°F* and < 120 °F.
APPLICABILITY: MODES 1, 2, 3, and 4.
ACTION:
a.
If the minimum containment average air temperature is less than 95°F* but greater than or equal to 90°F*, then within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> either restore containment air temperature to greater than or equal to 95°F or reduce the peak linear heat generation rate limit in accordance with the COLR. Otherwise, be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.
b.
If the minimum containment average air temperature is less than 90°F, then restore containment air temperature to greater than or equal to 95°F within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.
c.
If maximum containment average air temperature is greater than 120°F, then restore containment air temperature to less than or equal to 120°F within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.
SURVEILLANCE REQUIREMENTS 4.6.1.5 The primary containment average air temperature shall be the arithmetical average of the temperatures at any three of the following locations and shall be determined at least once per 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />s:
Location
- a. Containment Fan Cooler No. 1A Air Intake
- b. Containment Fan Cooler No. 1B Air Intake
- c. Containment Fan Cooler No. 1C Air Intake
- d. Containment Fan Cooler No. 1D Air Intake
- The minimum containment average air temperature limit is only applicable at greater than 70%
RATED THERMAL POWER.
214 Corrected by letter dated May 9, 2008