ML081190221
| ML081190221 | |
| Person / Time | |
|---|---|
| Site: | Susquehanna |
| Issue date: | 04/18/2008 |
| From: | Susquehanna |
| To: | Gerlach R Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| Download: ML081190221 (123) | |
Text
Apr.
18, 2008 Page 1
of 4
MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2008-17298 USER INFORMATION:
GERLACH*ROSE M EMPL#:028401 CA#:
0363 Address: NUCSA2 Phone#:
254-3194 TRANSMITTAL INFORMATION:
TO:
GERLACH*ROSE M LOCATION:
USNRC 04/18/2008 FROM:
NUCLEAR RECORDS DOCUMENT CONTROL CENTER (NUCSA-2)
THE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU.
HARDCOPY USERS MUST ENSURE THE DOCUMENTS PROVIDED MATCH THE INFORMATION ON THIS TRANSMITTAL.
WHEN REPLACING THIS MATERIAL IN YOUR HARDCOPY MANUAL, ENSURE THE UPDATE DOCUMENT ID IS THE SAME DOCUMENT ID YOU'RE REMOVING FROM YOUR MANUAL.
TOOLS FROM THE HUMAN PERFORMANCE TOOL BAG SHOULD BE UTILIZED TO ELIMINATE THE CHANCE OF ERRORS.
ATTENTION:
"REPLACE" directions do not affect the Table of Contents, Therefore no TOC will be issued with the updated material.
TRMl -
TECHNICAL REQUIREMENTS MANUAL UNIT 1 REMOVE MANUAL TABLE OF CONTENTS DATE: 04/13/2008 ADD MANUAL TABLE OF CONTENTS DATE: 04/17/2008 CATEGORY:
DOCUMENTS TYPE: TRMI A60(
Apr.
18, 2008 Page 2
of 4
ID:
TEXT 2.2 REMOVE:
REV:5 ADD:
REV:
6 CATEGORY:
DOCUMENTS TYPE: TRM1 ID:
TEXT 3.1.3 REMOVE:
REV:3 ADD:
REV:ý4 CATEGORY:
DOCUMENTS TYPE: TRM1 ID:
TEXT 3.10.4 ADD:
REV: 2 REMOVE:
REV:.1 CATEGORY:
DOCUMENTS TYPE: TRMI ID:
TEXT 3.12.2 ADD:
REV: 4 REMOVE:
REV:3 CATEGORY:
DOCUMENTS TYPE: TRM1 ID:
TEXT 3.2.1 ADD:
REV: 9 REMOVE:
REV:8 CATEGORY:
DOCUMENTS TYPE: TRMI ID:
TEXT 3.3.9 REMOVE:
REV:2
Apr.
18, 2008 Page 3
of 4
ADD:
REV: 3 CATEGORY:
DOCUMENTS ID:
TEXT 3.4.4 REMOVE:
REV:1 ADD:
REV: 2 CATEGORY:
DOCUMENTS ID:
TEXT B3.10.4 REMOVE:
REV:0 TYPE:
TRMI1 TYPE: TRMI ADD:
REV:
1 CATEGORY:
ID:
TEXT REMOVE:
DOCUMENTS TYPE: TRMI B3.3.9 REV:2 ADD:
REV: 3 CATEGORY:
DOCUMENTS ID:
TEXT B3.6.3 ADD:
REV: 2 TYPE: TRMI REMOVE:
REV:1 CATEGORY:
ID:
TEXT REMOVE:
DOCUMENTS LOES REV:44 TYPE: TRMI ADD:
REV: 45 CATEGORY:
DOCUMENTS TYPE: TRMI
Apr.
18, 2008 Page 4
of 4
ID:
TEXT TOC ADD:
REV:
15 REMOVE:
REV:14 ANY DISCREPANCIES WITH THE MATERIAL PROVIDED, CONTACT DCS @ X3107 OR X3136 FOR ASSISTANCE.
UPDATES FOR HARDCOPY MANUALS WILL BE DISTRIBUTED WITHIN 3 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.
PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON COMPLETION OF UPDATES.
FOR ELECTRONIC MANUAL
- USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.
SSES MANUAL Manual Name:
TRI Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1 Table Of Contents Issue Date:
0 Procedure Name TEXT LOES
Title:
LIST OF EF:
'4/17/2008 FECTIVE SECT Rev Issue Date 45 04/17/2008 IONS 15 04/17/2008 Change ID Change Number TEXT TOC
Title:
TABLE OF CONTENTS TEXT 1.1 0
11/18/2002
Title:
USE AND APPLICATION DEFINITIONS TEXT 2.1 1
02/04/20'05
Title:
PLANT PROGRAMS AND SETPOINTS PLANT PROGRAMS TEXT 2.2
Title:
TEXT 3.0
Title:
6
/04/17,/200/8/
PLANT PROGRAMS AND SETPOINTS] INSTRUMENT TRIP 7
7./
SETPOINT TABLE LDCN 4414 3,,
05/02/2007 TECHNICAL REQUIREMENT FOR OPERATION (TRO)
APPLICABILITY & SURVEILLANCE (TRS)
APPLICABILITY TEXT 3. 1.1 1
11/09/2007
Title:
REACTIVITY CONTROL SYSTEMS ANTICIPATED TRANSIENT WITHOUT SCRAM ALTERNATE ROD INJECTION-,(ATWS-ARI)
INSTRUMENTATION TEXT 3.1.2 0
11/18/2002
Title:
REACTIVITY-CONTROL SYSTEMS CONTROL ROD DRIVE (CRD)
HOUSING SUPPORT TEXT 3.1.3 4
04/17/2008
Title:
REACTIVITY CONTROL SYSTEMS CONTROL ROD BLOCK INSTRUMENTATION TEXT 3.1.4 0
11/18/2002
Title:
REACTIVITY CONTROL SYSTEMS CONTROL ROD SCRAM ACCUMULATORS INSTRUMENTATION &
CHECK VALVE TEXT 3.2.1 9
04/17/2008
Title:
CORE OPERATING LIMITS REPORT (COLR)
Page 1 of 15 Report Date: 04/17/08 Page 1 of.15 Report Date: 04/17/08
SSES MANUAL Manual Name:
TRM1 Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.3.1 0
11/18/2002
Title:
INSTRUMENTATION RADIATION MONITORING INSTRUMENTATION TEXT 3.3.2 2
11/09/2007
Title:
INSTRUMENTATION SEISMIC MONITORING INSTRUMENTATION TEXT 3.3.3 2
11/09/2007
Title:
INSTRUMENTATION METEOROLOGICAL MONITORING INSTRUMENTATION TEXT 3.3.4 4
11/09/200.7
Title:
INSTRUMENTATION TRM POST-ACCIDENT MONITORING INSTRUMENTATION TEXT 3.3.5 0
11/18/2002
Title:
INSTRUMENTATION THIS PAGE INTENTIONALLY LEFT BLANK 0
TEXT 3.3.6
Title:
INSTRUMENTATION 2
10/19/2005 TRM ISOLATION ACTUATION INSTRUMENTATION TEXT 3.3.7 1
11/09/2007
Title:
INSTRUMENTATION MAIN TURBINE OVERSPEED PROTECTION SYSTEM TEXT 3.3.8 1
10/22/2003
Title:
INSTRUMENTATION TRM RPS INSTRUMENTATION TEXT 3.3.9 3
04/17/2008
Title:
OPRM INSTRUMENTATION CONFIGURATION TEXT 3.3.10 1
12/14/2004
Title:
INSTRUMENTATION REACTOR RECIRCULATION PUMP MG TEXT 3.3.11 1
10/22/2003
Title:
INSTRUMENTATION MVP ISOLATION INSTRUMENTATION TEXT 3.4.1 1
04/26/2006
Title:
REACTOR COOLANT SYSTEM REACTOR COOLANT SYSTEM SET STOPS CHEMISTRY Page 2 of 15 Report Date:.04/17/08 Page 2 of i__55 Report Date:.04/17/08
SSES MANUAL Manual Name:
TRMI Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.4.2
Title:
REACTOR TEXT 3.4.3
Title:
REACTOR TEXT 3.4.4
Title:
REACTOR TEXT 3.4.5
Title:
REACTOR TEXT 3.5.1 0
11/18/2002 COOLANT SYSTEM STRUCTURAL INTEGRITY 1
11/09/2007 COOLANT SYSTEM HIGH/LOW PRESSURE INTERFACE LEAKAGE MONITORS 2
04/17/2008 COOLANT SYSTEM REACTOR RECIRCULATION FLOW AND ROD LINE LIMIT 1
04/26/2006 COOLANT SYSTEM REACTOR VESSEL MATERIALS 1
02/04/2005
Title:
EMERGENCY CORE COOLING AND RCIC ADS MANUAL INHIBIT TEXT 3.5.2 1
11/09/2007
Title:
EMERGENCY CORE COOLING AND RCIC ECCS AND RCIC SYSTEM MONITORING INSTRUMENTATION TEXT 3.5.3 0
11/18/2002
Title:
EMERGENCY CORE COOLING AND RCIC LONG TERM NITROGEN SUPPLY TO ADS TEXT 3.6.1 0
11/18/2002
Title:
CONTAINMENT VENTING OR PURGING TEXT 3.6.2 0
11/18/2002
Title:
CONTAINMENT SUPPRESSION CHAMBER-TO-DRYWELL VACUUM BREAKER POSITION INDICATION TEXT 3.6.3 0
11/18/2002
Title:
CONTAINMENT SUPPRESSION POOL ALARM INSTRUMENTATION TEXT 3.6.4 0
11/18/2002
Title:
CONTAINMENT PRIMARY CONTAINMENT CLOSED SYSTEM BOUNDARIES P
TEXT 3.7.1 0
11/18/2002
Title:
PLANT SYSTEMS EMERGENCY SERVICE WATER SYSTEM (ESW)
SHUTDOWN Page3 of i__55 Report Date: 04/17/08
SSES MANTJML Manual Name:
TRM1 Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.7.2
Title:
PLANT TEXT 3.7.3.1
Title:
PLANT TEXT 3.7.3.2
Title:
PLANT TEXT 3.7.3.3
Title:
PLANT TEXT 3.7.3.4
Title:
PLANT TEXT 3.7.3.5
Title:
PLANT 0
11/18/2002 SYSTEMS ULTIMATE HEAT SINK (UHS)
AND GROUND WATER LEVEL S1 04/26/2006 SYSTEMS FIRE SUPPRESSION WATER SUPPLY SYSTEM 2
04/26/2006 SYSTEMS SPRAY AND SPRINKLER SYSTEMS 2
SYSTEMS C02 SYSTEMS 08/18/2005 04/26/2006 SYSTEMS HALON SYSTEMS 1
04/26/2006 SYSTEMS FIRE HOSE STATIONS TEXT 3.7.3.6
Title:
PLANT SYSTEMS 1
04/26/2006 YARD FIRE HYDRANTS AND HYDRANT HOSE HOUSES TEXT 3.7.3.7
Title:
PLANT TEXT 3.7.3.8
Title:
PLANT TEXT 3.7.4
Title:
PLANT TEXT 3.7.5.1
Title:
PLANT TEXT 3.7.5.2
Title:
PLANT 1
04/26/2006 SYSTEMS FIRE RATED ASSEMBLIES 6
11/09/2007 SYSTEMS FIRE DETECTION INSTRUMENTATION 1
04/26/2006 SYSTEMS SOLID RADWASTE SYSTEM LDCN 3503 0
11/18/2002 SYSTEMS MAIN CONDENSER OFFGAS HYDROGEN MONITOR 0
11/18/2002 SYSTEMS MAIN CONDENSER OFFGAS EXPLOSIVE GAS MIXTURE Page 4 of 15 Report Date: 04/17/08 Page 4 of
__55 Report Date: 04/17/08
SSES MANUAL Manual Name:
TRM1 Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.7.5.3
Title:
PLANT SYSTEMS
- 1.
04/26/.2006 LIQUID HOLDUP TANKS TEXT 3.7.6 1
03/01/2005
Title:
PLANT SYSTEMS ESSW PUMPHOUSE VENTILATION TEXT 3.7.7 1
01/31/2008
Title:
PLANT SYSTEMS MAIN CONDENSER OFFGAS PRETREATMENT LOGARITHMIC RADIATION MONITORING TEXT 3.7.8 4
06/21/2007
Title:
PLANT SYSTEMS SNUBBERS TEXT 3.7.9 1
08/28/2006
Title:
PLANT SYSTEMS CONTROL STRUCTURE HVAC TEXT 3.7.10 1
12/14/2004
Title:
PLANT SYSTEMS SPENT FUEL STORAGE POOLS (SFSPS)
TEXT 3.8.1
Title:
ELECTRICAL PROTECTIVE TEXT 3.8.2.1
Title:
ELECTRICAL CONTINUOUS TEXT 3.8.2.2
Title:
ELECTRICAL AUTOMATIC 1
02/04/2005 POWER PRIMARY CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT DEVICES 2
11/09/2007 POWER MOTOR OPERATED VALVES (MOV)
THERMAL OVERLOAD 2
12/14/2004 POWER MOTOR OPERATED VALVES (MOV)
THERMAL OVERLOAD PROTECTION PROTECTION TEXT 3.8.3 0
11/18/2002
Title:
ELECTRICAL POWER DIESEL GENERATOR (DG)
MAINTENANCE ACTIVITIES TEXT 3.8.4 0
11/18/2002
Title:
ELECTRICAL POWER 24 VDC ELECTRICAL POWER SUBSYSTEM TEXT 3.8.5 0
11/18/2002
Title:
ELECTRICAL POWER. DEGRADED VOLTAGE PROTECTION Page 5 of 15 Report Date: 04/17/08 Page 5 of
.15 Report Date: 04/17/08
SSES MANUAL Manual Name:
TRMI Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3-8.6 0
11/18/2002
Title:
ELECTRICAL POWER EMERGENCY SWITCHGEAR ROOM COOLING TEXT 3.8.7 0
12/14/2006
Title:
BATTERY MAINTENANCE AND MONITORING PROGRAM TEXT 3,9.1.
0 11/18/2002
Title:
REFUELING OPERATIONS DECAY TIME TEXT 3.9.2 0
11/18/2002
Title:
REFUELING OPERATIONS COMMUNICATIONS TEXT 3.9.3 0
11/18/2002
Title:
REFUELING OPERATIONS REFUELING PLATFORM TEXT 3,10.1 1
04/26/2006
Title:
MISCELLANEOUS SEAL SOURCE CONTAMINATION TEXT 3,10.2 2
08/08/2006
Title:
MISCELLANEOUS SHUTDOWN MARGIN TEST RPS INSTRUMENTATION TEXT 3,10.3 1
04/26/2006
Title:
.MISCELLANEOUS INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI)
TEXT 3.10.4 2
04/17/2008
Title:
MISCELLANEOUS LEADING EDGE FLOW METER (LEFM)
TEXT 3,11.1.1 1
04/26/2006
Title:
RADIOACTIVE EFFLUENTS LIQUID EFFLUENTS CONCENTRATION TEXT 3.11.1.2 1
04/26/2006
Title:
RADIOACTIVE EFFLUENTS LIQUID EFFLUENTS DOSE TEXT 3.11.1.3 1
04/26/2006
Title:
RADIOACTIVE EFFLUENTS LIQUID WASTE TREATMENT SYSTEM Page 6 of 15 Report Date: 04/17/08 Page 6,
of 1_55 Report Date: 04/17/08
SSES MANUAL Manual Name:
TRMI Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.11.1.4
Title:
RADIOACTIVE TEXT 3.11.1.5
Title:
RADIOACTIVE TEXT 3.11.2.1
Title:
RADIOACTIVE TEXT 3.11.2.2
Title:
RADIOACTIVE TEXT 3.11.2.3
Title:
RADIOACTIVE FORM TEXT 3.11.2.4
Title:
RADIOACTIVE TEXT 3.11.2.5
Title:
RADIOACTIVE TEXT 3.11.2.6
Title:
RADIOACTIVE TEXT 3.11.3
Title:
RADIOACTIVE TEXT 3.11.4.1
Title:
RADIOACTIVE TEXT 3.11.4.2
Title:
RADIOACTIVE TEXT 3.11.4.3
Title:
RADIOACTIVE EFFLUENTS
.EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS 1
12/14/2004 LIQUID RADWASTE EFFLUENT MONITORING INSTRUMENTATION 2
05/02/2007 RADIOACTIVE LIQUID PROCESS MONITORING INSTRUMENTATION 3
04/26/2006 DOSE RATE 1
04/26/2006 DOSE NOBLE GASES 1
04/26/2006 DOSE -
11/18/2002 GASEOUS RADWASTE TREATMENT SYSTEM EFFLUENTS EFFLUENTS 3
11/14/2006 VENTILATION EXHAUST 3
05/02/2007 RADIOACTIVE GASEOUS TREATMENT SYSTEM EFFLUENT MONITORING INSTRUMENTATION EFFLUENTS EFFLUENTS EFFLUENTS EFFLUENTS 1
04/26/2006 TOTAL DOSE 4
08/08/2006 MONITORING PROGRAM 2
04/26/2006 LAND USE CENSUS
- 1.
04/26/2006 INTERLABORATORY COMPARISON PROGRAM Page 7 of 15 Report Date: 04/17/08 Page 7 of
.15 Report Date: 04/17/08
SSES MANUAL Manual Name:
TRMI Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.12.1 0
11/19/2002
Title:
'LOADS CONTROL PROGRAM CRANE TRAVEL-SPENT FUEL POOL STORAGE POOL TEXT 3.12.2 4
04/17/2008
Title:
LOADS CONTROL PROGRAM HEAVY LOADS REQUIREMENTS TEXT 3.12.3 0
11/19/2002
Title:
LOADS CONTROL PROGRAM LIGHT LOADS REQUIREMENT TEXT B3.0 3
05/02/2007
Title:
APPLICABILITY BASES TECHNICAL REQUIREMENT FOR OPERATION (TRO) APPLICABILITY TEXT B3.1.1 1
11/09/2007
Title:
REACTIVITY CONTROL SYSTEMS BASES ANTICIPATED TRANSIENT WITHOUT SCRAM ALTERNATE ROD INJECTION (ATWS-ARI)
INSTRUMENTATION TEXT B3.1.2 0
11/19/2002
Title:
REACTIVITY CONTROL SYSTEMS BASES CONTROL ROD DRIVE *(CRD) HOUSING SUPPORT TEXT B3.1*.3 3
03/31/2006
Title:
REACTIVITY CONTROL SYSTEMS BASES CONTROL ROD BLOCK INSTRUMENTATION TEXT B3.1.4 0
11/19/2002
.Title:
REACTIVITY CONTROL SYSTEMS BASES.CONTROL ROD.SCRAM ACCUMULATORS INSTRUMENTATION AND CHECK VALVE TEXT B3.2.1 0
11/19/2002
Title:
CORE OPERATING LIMITS BASES CORE OPERATING LIMITS REPORT (COLR)
TEXT B3.3.1 0
11/19/2002
Title:
INSTRUMENTATION BASES RADIATION MONITORING INSTRUMENTATION TEXT B3.3.2 1
11/09/21007
Title:
INSTRUMENTATION BASES SEISMIC MONITORING INSTRUMENTATION TEXT B3.3.3 2
11/09/2007
Title:
INSTRUMENTATION BASES METEOROLOGICAL MONITORING INSTRUMENTATION Page 8 of 1_55 Report Date: 04/17/08
SSESMANUAL Manual Name:
TRMI Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.3.4 3
11/09/2007
Title:
INSTRUMENTATION BASES TRM POST ACCIDENT MONITORING (PAM)
INSTRUMENTATION TEXT B3.3.5 2
11/09/2007
Title:
INSTRUMENTATION BASES THIS PAGE INTENTIONALLY LEFT BLANK TEXT B3.3.6 3
10/19/2005
Title:
INSTRUMENTATION BASES TRM ISOLATION ACTUATION INSTRUMENTATION TEXT B3.3.7
Title:
INSTRUMENTATION BASES 1
11/09/2007 MAIN TURBINE OVERSPEED PROTECTION SYSTEM TEXT B3.3.8 1
10/22/2003
Title:
INSTRUMENTATION BASES TRM REACTOR PROTECTION SYSTEM (RPS)
INSTRUMENTATION TEXT B3.3.9
Title:
OPRM INSTRUMENTATION 3
04/17/2008 TEXT B3.3.10
Title:
INSTRUMENTATION TEXT B3.3.11
.Title:
INSTRUMENTATION TEXT B3.4.1
Title:
11/19/2002 BASES REACTOR RECIRCULATION PUMP MG SET STOPS 1
10/22/2003 BASES MVP ISOLATION INSTRUMENTATION 0
11/19/2002 SYSTEM BASES REACTOR COOLANT SYSTEM CHEMISTRY TEXT B3.4.2 0
11/19/2002
Title:
REACTOR COOLANT SYSTEM BASES STRUCTURAL INTEGRITY TEXT B3.4.3 1
11/09/2007
Title:
REACTOR COOLANT SYSTEM BASES HIGH/LOW PRESSURE INTERFACE LEAKAGE MONITOR TEXT B3.4.4 0
11/19/2002
Title:
REACTOR COOLANT SYSTEM BASES REACTOR RECIRCULATION FLOW AND ROD LINE LIMIT Page9 of i_55 Report Date: 04/17/08
SSES MANUAL Manual Name:
TRMI Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.4.5 0
11/19/2002
Title:
REACTOR COOLANT. SYSTEM BASES REACTOR VESSEL MATERIALS TEXT B3.5.1 0
11/19/2002
Title:
ECCS AND RCIC BASES ADS MANUAL INHIBIT TEXT B3.5.2 1
11/09/2007
Title:
ECCS AND RCIC BASES ECCS AND RCIC SYSTEM MONITORING INSTRUMENTATION TEXT B3.5.3 1
11/09/200.7
Title:
ECCS AND RCIC BASES LONG TERM NITROGEN SUPPLY TO ADS TEXT B3.6.1 0
11/19/2002
Title:
CONTAINMENT BASES VENTING OR PURGING TEXT B3.6.2 0
11/19/2002
Title:
CONTAINMENT BASES SUPPRESSION CHAMBER-TO-DRYWELL VACUUM BREAKER POSITION INDICATION TEXT B3.6.3 2
04/17/2008
Title:
CONTAINMENT BASES SUPPRESSION POOL ALARM INSTRUMENTATION LDCN 3933 TEXT B3.6.4 1
12/14/2004
Title:
CONTAINMENT BASES PRIMARY CONTAINMENT CLOSED SYSTEM BOUNDARIES TEXT B3.7.1 0
11/19/2002
Title:
PLANT SYSTEMS BASES EMERGENCY SERVICE WATER SYSTEM (SHUTDOWN)
TEXT B3.7.2 0
11/19/2002
Title:
PLANT SYSTEMS BASES ULTIMATE HEAT SINK (UHS)
GROUND WATER LEVEL TEXT B3.7.3.1 2
01/07/2008
Title:
PLANT SYSTEMS BASES FIRE SUPPRESSION WATER SUPPLY SYSTEM TEXT B3.7.3.2 2
04/26/2006
Title:
PLANT SYSTEMS BASES SPRAY AND SPRINKLER SYSTEMS
.Page i__0 of
.__55 Report Date: 04/17/08
SSES MANUAL Manual Name:
TRM1 Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.7.3.3
Title:
PLANT TEXT B3.7.3.4
Title:
PLANT TEXT B3.7.3.5
Title:
PLANT TEXT B3.7.3.6
Title:
PLANT TEXT B3.7.3.7
Title:
PLANT TEXT B3.7.3.8
Title:
PLANT TEXT B3.7.4
Title:
PLANT TEXT B3.7.5.1
Title:
PLANT TEXT B3.7.5.2
Title:
PLANT TEXT B3.7.5.3
Title:
PLANT TEXT B3.7.6
Title:
PLANT SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES SYSTEMS BASES 0
11/19/2002 C02 SYSTEMS 1
04/26/2006 HALON SYSTEMS 1
04/26/2006 FIRE HOSE STATIONS
.1 04/26/2006 YARD FIRE HYDRANTS AND HYDRANT 0
11/19/2002 FIRE RATED ASSEMBLIES 1
01/12/2004 FIRE DETECTION INSTRUMENTATION 0
11/19/2002.
SOLID RADWASTE SYSTEM 0
11/19/2002 MAIN CONDENSER OFFGAS HYDROGEN 0
11/19/2002 MAIN CONDENSER OFFGAS EXPLOSIVE 0
11/19/2002 LIQUID HOLDUP TANKS 1
03/01/2005 ESSW PUMPHOUSE VENTILATION 2
01/31/2008 HOSE HOUSES MONITOR GAS MIXTURE TEXT B3.7.7 W
Title:
PLANT SYSTEMS BASES MAIN CONDENSER OFFGAS PRETREATMENT LOGARITHMIC RADIATION MONITORING INSTRUMENTATION Page 11 of
.1_55 Report Date: 04/17/08
SSES MANUAL Manual Name:
TRM1 Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.7.8 3
06/21/2007
Title:
PLANT SYSTEMS BASES'SNUBBERS TEXT B3.7.9 1
12/14/2004
Title:
PLANT SYSTEMS BASES CONTROL STRUCTURE HVAC TEXT B3.7.10 1
12/14/2004
Title:
PLANT SYSTEMS BASES SPENT FUEL STORAGE POOLS TEXT B3.8.1
Title:
ELECTRICAL PROTECTIVE TEXT B3.8.2.1
Title:
ELECTRICAL CONTINUOUS TEXT B3.8.2.2
Title:
ELECTRICAL AUTOMATIC TEXT B3.8.3
Title:
ELECTRICAL TEXT B3.8.4
Title:
ELECTRICAL TEXT B3.8.5
Title:
ELECTRICAL TEXT B3.8.6
Title:
ELECTRICAL TEXT B3.8.7 1
.02/04/2005 POWER BASES PRIMARY CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT DEVICES 0
11/19/2002 POWER BASES MOTOR OPERATED VALVES (MOV)
THERMAL OVERLOAD 09/17/2004 POWER BASES MOTOR OPERATED VALVES (MOV)
THERMAL OVERLOAD PROTECTION PROTECTION 0
11/19/2002 POWER BASES DIESEL GENERATOR (DG)
MAINTENANCE 0
11/19/2002 POWER BASES 24 VDC ELECTRICAL POWER SUBSYSTEM 0
11/19/2002 POWER BASES DEGRADED VOLTAGE PROTECTION 1
02/04/2005 POWER BASES EMERGENCY SWITCHGEAR ROOM COOLING 0
12/14/2006 ACTIVITIES
Title:
BATTERY MAINTENANCE AND MONITORING PROGRAM TEXT B3..9.1 0
11/19/2002
Title:
REFUELING OPERATIONS BASES DECAY TIME Page 12 of 15 Report Date: 04/17/08 Page 12 of 15 Report Date: 04/17/.08
SSES MANUAL Manual Name:
TRM1 Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.9.2 0
Title:
REFUELING OPERATIONS BASES TEXT B3.9.3.
0
Title:
REFUELING OPERATIONS BASES 11/19/2002 COMMUNICATIONS 11/19/2002 REFUELING PLATFORM TEXT B3.10.1
Title:
MISCELLANEOUS 0
11/19/2002 BASES SEALED SOURCE CONTAMINATION TEXT B3.10.2 1
03/31/2006
Title:
MISCELLANEOUS BASES SHUTDOWN MARGIN TEST RPS INSTRUMENTATION TEXT B3.10.3 0
11/19/2002
Title:
MISCELLANEOUS BASES INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI)
TEXT B3.10.4 1
04/17/2008
Title:
MISCELLANEOUS BASES LEADING EDGE FLOW METER (LEFM)
TEXT B3.11.1.1
Title:
RADIOACTIVE TEXT B3.11.1.2
Title:
RADIOACTIVE TEXT B3.11.1.3
Title:
RADIOACTIVE TEXT B3.11.1.4
Title:
RADIOACTIVE TEXT B3.11.1.5
Title:
RADIOACTIVE EFFLUENTS EFFLUENTS 0
11/19/2002 BASES LIQUID EFFLUENTS CONCENTRATION 0
11/19/2002 BASES LIQUID EFFLUENTS DOSE 0
11/19/2002 EFFLUENTS BASES LIQUID WASTE TREATMENT SYSTEM 0
11/19/2002 EFFLUENTS BASES LIQUID RADWASTE EFFLUENT MONITORING INSTRUMENTATION 0
11/19/2002 EFFLUENTS BASES RADIOACTIVE LIQUID PROCESS MONITORING INSTRUMENTATION TEXT B3.11.2.1 1
Title:
RADIOACTIVE EFFLUENTS BASES 12/14/2004 DOSE RATE Page 13.
of 15 Report Date: 04/17/08 Page 13.
o f 15 Report Date: 04/17/08
SSES MANUAL Manual Name:
TRMI Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.11.2.2 0
11/19/2002
Title:
RADIOACTIVE EFFLUENTS BASES DOSE -
NOBLE GASES 0
TEXT B3.11.2.3
Title:
RADIOACTIVE EFFLUENTS PARTICULATES FORM TEXT B3.11.2.4
Title:
RADIOACTIVE EFFLUENTS 0
11/19/2002 BASES DOSE.-
11/19/2.002 BASES GASEOUS RADWASTE TREATMENT SYSTEM TEXT B3.11.2.5 4
11/14/2006
Title:
RADIOACTIVE EFFLUENTS BASES VENTILATION EXHAUST TREATMENT SYSTEM TEXT B3.11.2.6
Title:
RADIOACTIVE EFFLUENTS INSTRUMENTATION 1
01/27/2004 BASES RADIOACTIVE GASEOUS EFFLUENT MONITORING TEXT B3.11.3 0
11/19/2002
Title:
RADIOACTIVE EFFLUENTS BASES TOTAL DOSE TEXT B3.11.4.1 2
01/06/2006
Title:
RADIOACTIVE EFFLUENTS BASES MONITORING PROGRAM TEXT B3.11.4.2 0
11/19/2002
Title:
RADIOACTIVE EFFLUENTS BASES LAND USE CENSUS TEXT B3.11.4.3 0
11/19/2002
Title:
RADIOACTIVE EFFLUENTS BASES INTERLABORATORY COMPARISON PROGRAM TEXT B3.12.1 1
10/04/2007
Title:
LOADS CONTROL PROGRAM BASES CRANE TRAVEL-SPENT FUEL STORAGE POOL TEXT B3.12.2
Title:
LOADS CONTROL PROGRAM TEXT B3.12.3
Title:
LOADS CONTROL PROGRAM 0
11/19/2002 BASES HEAVY LOADS REQUIREMENTS 0
11/19/2002 BASES LIGHT LOADS REQUIREMENTS Page 14 of 15 Report Date: 04/17/08 Page 14 of
.15 Report Date: 04/17/08
SSES MANUAL Manual Name:
TRM1 Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 4.1
Title:
TEXT 4..2
Title:
TEXT 4.3
Title:
TEXT 4.4
Title:
TEXT 4.5
Title:
TEXT 4.6
Title:
TEXT 4.7
Title:
ADMINISTRATIVE ADMINISTRATIVE ADMINISTRATIVE ADMINISTRATIVE ADMINISTRATIVE ADMINISTRATIVE ADMINISTRATIVE 0
08/31/1998 CONTROLS ORGANIZATION 0
08/31/1998 CONTROLS REPORTABLE EVENT ACTION 0
08/31/1998 CONTROLS SAFETY LIMIT VIOLATION 0
08/31/1998 CONTROLS PROCEDURES & PROGRAMS 0
08/31/1998 CONTROLS REPORTING REQUIREMENTS 0
08/31/1998 CONTROLS RADIATION PROTECTION PROGRAM 0
08/31/1998 CONTROLS TRAINING Page 15 of 15 Report Date: 04/17/08 Page 15 of
.15 Report Date: 04/17/08
SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 15 TABLE OF CONTENTS (TECHNICAL REQUIREMENTS MANUAL)
SECTION TITLE PAGE 1.0 USE AND APPLICATION
................................. TRM/1.0-1 1.1 D efinitions.........................................................................................
T R M /1.0-2 2.0 P LA N T P R O G R A M S.......................................................................................
2.0-1 2.1 P la nt P rog ra m s..........................................................................................
2.0-1 2.2 Instrum ent Trip Setpoint Table..........................................................
TRM/2.0-5 3.0 A P P LIC A B ILITY.....................................................................................
T R M /3.0-1 3.0 TRO) - TR for Operation (TRO) Applicability........
TRM/3.0-1 3.0
ý(TRS) - TR Surveillance (TRS) Applicability.....................................
TRM/3.0-3 3.1 REACTIVITY CONTROL SYSTEMS.................................
............... TRM/3.1-1 3.1.1 Alternate Rod Injection......
TRM/3.1-1 3.1.2 CRD Housing Support.....................................
3.1-4 3.1.3 Control Rod Block Instrum entation..................... :...................................... 3.1-5 3.1.4 Control Rod Scram Accumulators Instrumentation and Check Valve
........ TRM/3.1-9 3.2 CORE OPERATING LIMITS REPORT...................................................
TRM/3.2-1 3.2.1 Core O perating Lim its Report.............................................................
TRM/3.2-1 3.3 INSTRUMENTATION.............................
...... TRM/3.3-1 3.3.1 Radiation Monitoring Instrumentation................................................
TRM/3.3-1 3.3.2 Seismic Monitoring Instrumentation...................................................
TRM/3.3-4 3.3.3 Meteorological Monitoring Instrumentation...................
TRM/3.3-7 3.3.4 TRM Post-Accident Monitoring Instrumentation.................................
TRM/3.3-9 3.3.5 Section Not Used TRM/3.3-12 3.3.6 TRM Containment Isolation Instrumentation......................................
TRM/3.3-13 3.3.7.
Turbine Overspeed Protection System..............................................
TRM/3.3-17 3.3.8 Section Not Used TRM/3.3-19 3.3.9 O PRM Instrum entation......................................................................
TRM/3.3-22 3.3.10 Reactor Recirculation Pump MG Set Electrical and M echanical Stops..............................................................................
T R M /3.3-23 3.3.11 MVP Isolation Instrumentation...........................
TRM/3.3-25 3.4 REACTOR COOLANT SYSTEM.............................................................
TRM/3.4-1 3.4.1 Reactor Coolant System Chemistry...................................................
TRM/3.4-1 3.4.2 S tructural Integrity......................................................................................
3.4-6 3.4.3 High/Low Pressure Interface Leakage Monitors.........................................
3.4-9 3.4.4 Reactor Recirculation Flow and Rod Line Limit.................................
TRM/3.4-12 3.4.5 Reactor Vessel Material Surveillances Program...............
TRM/3.4-13 SUSQUEHANNA - UNIT 1 TRM / TOC-1 EFFECTIVE DATE 03/27/2008
SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 15 TABLE OF CONTENTS (TECHNICAL REQUIREMENTS MANUAL)
SECTION TITLE PAGE 3.5 EMERGENCY CORE COOLING AND RCIC..........................................
TRMI3.5-1 3.5.1 A D S M anual Inhibit...........................................................................
T R M /3.5-1 3.5.2 ECCS and RCIC System Monitoring Instrumentation.................................
3.5-3 3.5.3 Long Term Nitrogen Supply to ADS...........................................................
3.5-6 3.6 CONTAINMENT.....
...................................... 3.6-1 3.6.1 V E NT IN G or P U R G IN G............................................................................
3.6-1 3.6.2 Suppression Chamber-to-Drywell Vacuum Breaker Position In d ic a tio n....................................................................................................
3.6 -2 3.6.3 Suppression Pool Alarm Instrumentation....................................................
3.6-3 3.6.4 Primary Containment Closed System Boundaries.............................
TRM/3.6-6 3.7 P LA N T S Y S T E M S...........................................................................................
3.7-1 3.7.1 Emergency Service Water System (Shutdown)..........................................
3.7-1 3.7.2 Ultimate Heat Sink and Ground Water Level..............................................
3.7-3 3.7.3.1 Fire Suppression Water Supply System............................................
TRM/3.7-4 3.7.3.2 Spray and Sprinkler Systems............................................................
TRM/3.7-8 3.7.3.3 C 0 2 S ystem s....................................................................................
T R M /3.7-12 3.7.3.4 H alon S ystem s..................................................................................
T R M /3.7-16 3.7.3.5 Fire H ose S tations..................... :........................................................ TR M /3.7-18 3.7.3.6 Yard Fire Hydrants and Hydrant Hose Houses..................................
TRM/3.7-22 3.7.3.7 Fire Rated Assemblies................................
TRM/3.7-24 3.7.3.8 Fire Detection Instrumentation..........................................................
TRM/3.7-26 3.7.4 Solid Radwaste System....................................................................
TRM/3.7-35 3.7.5.1 Main Condenser Offgas Hydrogen Monitor................................................
3.7-38 3.7.5.2 Main Condenser Explosive Gas Mixture.....................................................
3.7-39 3.7.5.3 Liquid Holdup Tanks.........................................................................
TRM/3.7-40 3.7.6 ESSW Pumphouse Ventilation..........................................................
TRM/3.7-41 3.7.7 Main Condenser Offgas Pretreatment Logarithmic Radiation Monitoring Instrumentation................................................................
TRM/3.7-42 3.7.8 S nubbers...........................................................................................
T R M /3.7-44 3.7.9 Control Structure HVAC....................................................................
TRM/3.7-50 3.7.10 Spent Fuel Storage Pools...............................................................
TRM/3.7-52 SUSQUEHANNA
- UNIT 1 TRM / TOC-2 EFFECTIVE DATE 03/27/2008 SUSQUEHANNA - UNIT 1 TRM /TOC-2 EFFECTIVE DATE 03/27/2008
SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 15 TABLE OF CONTENTS (TECHNICAL REQUIREMENTS MANUAL)
SECTION TITLE PAGE 3.8 ELECTRICAL POWER...........................................................................
TRM/3.8-1 3.8.1 Primary Containment Penetration Conductor Overcurrent Protective Devices............................................................................
TRM/3.8-1 3.8.2.1 Motor Operated Valves Thermal Overload Protection -
C o ntinuo us........................................................................................
T R M /3.8-5 3.8.2.2 Motor Operated Valves Thermal Overload Protection -
A uto m atic..........................................................................................
T R M /3.8-11 3.8.3 Diesel Generator (DG) Maintenance Activities......... *................................. 3.8-13 3.8.4 24VDC Electrical Power Subsystem..................................................
TRM/3.8-15 3.8.5 Degraded Voltage Protection............................................................
TRM/3.8-21 3.8.6 Emergency Switchgear Room Cooling.......................................................
3.8-24 3.8.7 Battery Monitoring and Maintenance Program..................................
TRM/3.8-26 3.9 REFUELING OPERATIONS............................................................................
3.9-1 3.9.1 D e ca y T im e...............................................................................................
3.9 -1 3.9.2 C om m unications........................................................................................
3.9-2 3.9.3 R efueling P latform......................................................................................
3.9-3 3.10 MISCELLANEOUS...................................................................................
TRM/3.10-1 3.10.1 Sealed Source Contamination.............................................................
TRM/3.10-1 3.10.2 MODE 5 Shutdown Margin Test RPS Instrumentation...............................
3.10-4 3.10.3 Independent Spent Fuel Storage Installation (ISFSI).........................
TRM/3.10-7 3.11 RADIOACTIVE EFFLUENTS..................................................................
TRM/3. 11-1 3.11.1.2 Liquid Effluents Concentration...........................................................
TRM/3.11-1 3.11.1.2 Liquid Effluents Dose........................................................................
TRM/3.11-4 3.11.1.3 Liquid Waste Treatment System.......................................................
TRM/3.11-6 3.11.1.4 Liquid Radwaste Effluent Monitoring Instrumentation................................
3.11-8 3.11.1.5 Radioactive Liquid Process Monitoring Instrumentation................... TRM/3.11-13 3.11.2.1 D ose R ate.................................
....................................................... T R M /3.11-17 3.11.2.2 Dose - Noble Gases.........................................................................
TRM/3.11-20 3.11.2.3 Dose - Iodine, Tritium, and Radionuclides in P articulate Form................................................................................
T R M /3.11-2 1 3.11.2.4 Gaseous Radwaste Treatment System.............................................
TRM/3.11-22 3.11.2.5 Ventilation Exhaust Treatment System..............................................
TRM/3.11-23 3.11.2.6 Radioactive Gaseous Effluent Monitoring Instrum entation...................................................................................
T R M /3.11-25 3.11.3 T otal D ose...........................................................................................
T R M /3.11-33 3.11.4.1 Monitoring Program.............................................................................
TRM/3.11-35 3.11.4.2 Land Use Census................................................................................
TRM/3.11-45 3.11.4.3 Interlaboratory Comparison Program..................................................
TRM/3.11-47 SUSQUEHANNA
- UNIT I TRM / TOC-3 EFFECTIVE DATE 03/27/2008 SUSQUEHANNA - UNIT 1 TRM / TOC-3 EFFECTIVE DATE 03/27/2008
SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 15 TABLE OF CONTENTS (TECHNICAL REQUIREMENTS MANUAL)
SECTION TITLE PAGE 3.12 LOADS CONTROL PROGRAM i................................
........................ TRM/3.12-1 3.12.1 Crane Travel - Spent Fuel StoragePool.................................................
TRM/3.12-1 3.12.2 Heavy Loads Requirements.................................................................. TRM/3.12-3 3.12.3 Light Loads Requirements.................................................................... TRM/3.12-5 4.0 ADMINISTRATIVE CONTROLS.....................................................................
4.0-1 4.1 O rg a n iza tio n...................................................................................................
4.0 -1 4.2 Reportable Event Action..................................................................................
4.0-2 4.3 Safety Limit Violation.......................................................................................
4.0-3 4.4 Procedures and Programs...............................................................................
4.0-4 4.5 Reporting Requirements..................................................................................
4.0-5 4.6 Radiation Protection Program..........................................................................
4.0-7 4.7 T ra in in g............................................................................................................
4.0 -8 SUSQUEHANNA
- UNIT I TRM / TOC-4 EFFECTIVE DATE 03/27/2008 SUSQUEHANNA - UNIT 1 TRM / TOC-4 EFFECTIVE DATE 03/27/2008
SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 15 TABLE OF CONTENTS (TECHNICAL REQUIREMENTS MANUAL)
SECTION TITLE PAGE B 3.0 A p p lica b ility................................................................................................
B 3.0-1 B 3.0 (TRO) - TR for Operation (TRO) Applicability.............................................
B 3.0-1 B 3.0 (TRS) - TR Surveillance (TRS) Applicability...............................................
B 3.0-9 B 3.1.1 A lternate Rod Injection.....................................................................
TRM/B 3.1-1 B 3.1.2 CRD Housing Support.......................................................................
TRM /B 3.1-4 B 3.1.3 Control Rod Block Instrumentation....................................................
TRM/B 3.1-5 B 3.1.4 Control Rod Scram Accumulators Instrumentation and Check Valve.....................................
....... TRM/B 3.1-8 B 3.2.1 Core Operating Limits Report (COLR)........................................................
B 3.2-1 B 3.3.1 Radiation Monitoring Instrumentation......................
TRM/B 3.3-1 B 3.3.2 Seismic Monitoring Instrumentation...................................................
TRM/B 3.3-2 B 3.3.3 Meteorological Monitoring Instrumentation........................................
TRM/B 3.3-3 B 3.3.4 TRM Post-Accident Monitoring Instrumentation...............
TRM/B 3.3-4 B 3.3.5 S ection Not Used..............................................................................
T RM /B 3.3-9 B 3.3.6 TRM Containment Isolation Instrumentation...............................................
B 3.3-10 B 3.3.7 Turbine Overspeed Protection System..............................................
TRM/B 3.3-14 B 3.3.8 Section Not Used.............................................................................
TRM /B 3.3-15 B 3.3.9 O PRM Instrum entation......................................................................
TRM /B 3.3-17 B 3.3.10 Reactor Recirculation Pump MG Set Electrical and Mechanical Stops.......
... TRM/B 3.3-18 B 3.3.11 MVP.Isolation Instrumentation...........................................................
TRM/B 3.3-20 B 3.4.1 Reactor Coolant System Chemistry............................................................
B 3.4-1 B 3.4.2 Structural Integrity........................................
B 3.4-2 B 3.4.3 High/Low Pressure Interface Leakage Monitors................................
TRM/B 3.4-4 B 3.4.4 Reactor Recirculation Flow and Rod Line Limit.................................
TRM/B 3.4-5 B 3.4.5 Reactor Vessel Material Surveillances Program.........................................
B 3.4-6 B 3.5.1 A D S M anual Inhibit...................................................................................
B 3.5-1 B 3.5.2 ECCS and RCIC System Monitoring Instrumentation........................
TRM/B 3.5-3 B 3.5.3 Long Term Nitrogen Supply to ADS..................................................
TRM/B 3.5-4 SUSQUEHANNA - UNIT 1 TRM /TOC-5 EFFECTIVE DATE 03/27/2008
SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 15 TABLE OF CONTENTS (TECHNICAL REQUIREMENTS MANUAL)
SECTION TITLE PAGE B 3.6.1 VENTING or PURGING....................................................................
TRM/B 3.6-1 B 3.6.2 Suppression Chamber-to-Drywell Vacuum Breaker Position In d ic a tio n..............................................................................
..................... B 3.6 -3 B 3.6.3 Suppression Pool Alarm Instrumentation...........................................
TRM/B 3.6-4 B 3.6.4 Primary Containment Closed System Boundaries.............................
TRM/B 3.6-6 B 3.7.1 Emergency Service Water System (Shutdown)..........................................
B 3.7-1 B 3.7'2 Ultimate Heat Sink and Ground Water Level..............................................
B 3.7-2 B 3.7.3.1 Fire Suppression Water Supply System.
TRM/B 3.7-3 B 3.7.3.2 Spray and Sprinkler Systems.............................................................
TRM/B 3.7-5 B 3.7.3.3 C 0 2 system s....................................................................................
T R M /B 3.7-7 B 3.7.3.4 H alon S ystem s......................... :........................................................ T R M /B 3.7-8 B 3.7.3.5 Fire Hose Stations.............................................................................
TRM/B 3.7-10 B 3.7.3.6 Yard Fire Hydrants and Hydrant Hose Houses..................................
TRM/B 3.7-11 B 3.7.3.7 Fire Rated Assemblies......................................................................
TRM/B 3.7-12 B 3.7.3.8 Fire Detection Instrumentation..........................................................
TRM/B 3.7-14 B 3.7.4 Solid Radwaste System....................................................................
TRM/B 3.7-15 B 3.7.5.1 Main Condenser Offgas Hydrogen Monitor................................................
B 3.7-17 B 3.7.5.2 Main Condenser Explosive Gas Mixture.....................................................
B 3.7-19 B 3.7.5.3 Liquid H oldup Tanks..................................................................................
B 3.7-20 B 3.7.6 ESSW Pumphouse Ventilation.........................................................
TRM/B 3.7-21 B 3.7.7 Main Condenser Offgas Pretreatment Logarithmic Radiation Monitoring Instrumentation................................................................
TRM/B 3.7-22 B 3.7.8 S nubbers...........................................................................................
T R M /B 3.7-24 B 3.7.9 Control Structure HVAC....................................................................
TRM/B 3.7-31 B 3.7.10 Spent Fuel Storage Pools.................................................................
TRM/B 3.7-33 B 3.8.1 Primary Containment Penetration Conductor Overcurrent P rotective D evices............................................................................
T R M /B 3.8-1 B 3.8.2.1 Motor Operated Valves Thermal Overload Protection -
C ontinuous........................................................................................
T R M /B 3.8-3 B 3.8.2.2 Motor Operated Valves Thermal Overload Protection -
A utom atic..........................................................................................
T R M /B 3.8-4 B 3.8.3 Diesel Generator (DG) Maintenance Activities...........................................
B 3.8-5 B 3.8.4 24VDC Electrical Power Subsystem...........................................................
B 3.8-6 B 3.8.5 Degraded Voltage Protection...........................................................
TRM/B 3.8-16 B 3.8.6 Emergency Switchgear Room Cooling..............................................
TRM/B 3.8-17 B 3.8.7 Battery Monitoring and Maintenance Program..................................
TRM/B 3.8-18 B.3.9.1 D e cay T im e................................................................................................
B 3.9-1 B 3.9.2 C om m unications........................................................................................
B 3.9-2 SUSQUEHANNA -
UNIT 1 TRM / TOC-6 EFFECTIVE DATE 03/27/2008 SUSQUEHANNA - UNIT 1 TRM / TOC-6 EFFECTIVE DATE 03/27/2008
SUSQUEHANNA STEAM ELECTRIC STATION TABLE OF CONTENTS (TECHNICAL REQUIREMENTS MANUAL)
PPL Rev. 15 SECTION B 3.9.3 B 3.10.1 B 3.10.2 B 3.10.3 B 3.11.1.1 B 3.11.1.2 B 3.11.1.3 B 3.11.1.4 B 3.11.1.5 B 3.11.2.1 B 3.11.2.2 B 3.11.2.3 B 3.11.2.4 B 3.11.2.5 B 3.11.2.6 B 3.11.3 B 3.11.4.1 B 3.11.4.2 B 3.11.4.3 B.3.12.1 B.3.12.2 B.3.12.3 TITLE PAGE Refueling Platform......................................................................................
B 3.9-3 Sealed Source Contamination....................................................................
B 3.10-1 MODE 5 Shutdown Margin Test RPS Instrumentation...................... TRM/B 3.10-2 Independent Spent Fuel Storage Installation (ISFSI).........................
TRM/B 3.10-4 Liquid Effluents Concentration....................................................................
B 3.11-1 Liquid Effluents Dose.................................................................................
B 3.11-4 Liquid W aste Treatment System................................................................
B 3.11-6 Liquid Radwaste Effluent Monitoring Instrumentation.................................
B 3.11-7 Radioactive Liquid Process Monitoring Instrumentation.................... TRM/B 3.11-10 Dose Rate.........................................................................................
TRM/B 3.11-12 Dose - Noble Gases...................................................................................
B 3.11-16 Dose - Iodine, Tritium, and Radionuclides in Particulate Form.........................................................................................
B 3.11-18 Gaseous Radwaste Treatment System.............................................
TRM/B 3.11-20 Ventilation Exhaust Treatment System..............................................
TRM/B 3.11-21 Radioactive Gaseous Effluent Monitoring Instrumentation.................................................................................
TRM/B 3.11-24 T o ta l D o se..................................................................................................
B 3.1 1-2 6 Monitoring Program...........................................................................
TRM/B 3.11-28 Land Use Census.......................................................................................
B 3.11-34 Interlaboratory Comparison Program................................................
TRM/B 3.11-36 Crane Travel - Spent Fuel Storage Pool...........................................
TRM/B 3.12-1 Heavy Loads Requirements.............................................................
TRM/B 3.12-2 Light Loads Requirements................................................................
TRM/B 3.12-3 TRM1 text TOC 4/8/05 SUSQUEHANNA - UNIT 1 TRM/TOC-7 EFFECTIVE DATE 03/27/2008 SUSQUEHANNA - UNIT 1 TRM /TOC-7 EFFECTIVE DATE 03/27/2008
SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 45 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)
Section Title TOC 1.0 2.0 3.0 3.1 TABLE OF CONTENTS USE AND APPLICATION Pages TRM / 1.0-1 through TRM / 1.0-3 PLANT PROGRAMS Page 2.0-1 Pages TRM / 2.0-2 and TRM / 2.0-3 Page TRM / 2.0-4 Page TRM / 2.0-5 Page TRM / 2.0-6 Page TRM / 2.0-7 Page TRM / 2.0-8 Pages TRM / 2.0-9 through TRM / 2.0-11 Page TRM / 2.0-12 Pages TRM / 2.0-13 and TRM / 2.0-14 Page TRM / 2.0-15 APPLICABILITY Page TRM / 3.0-1 Page TRM / 3.0-2 Page TRM / 3.0-3 Page TRM / 3.0-4 REACTIVITY CONTROL SYSTEMS Page TRM / 3.1-1 Pages TRM / 3.1-2 through TRM / 3.1-5 Page TRM / 3.1-6 Pages TRM / 3.1-7 and TRM / 3.1-8 Pages TRM / 3.1-9 and TRM / 3.1-9a Page TRM / 3.1-10 CORE OPERATING LIMITS REPORT Page TRM / 3.2-1 Pages TRM / 3.2-2 through TRM / 3.2-44 INSTRUMENTATION Pages TRM / 3.3-1 through TRM / 3.3-3 Page TRM / 3.3-4 and TRM / 3.3-5 Page TRM / 3.3-6 Page TRM / 3.3-7 Page 3.3-8 Page TRM / 3.3-9 Page TRM / 3.3-9a Page TRM / 3.3-10 Page TRM / 3.3-11 Page TRM / 3.3-1 la Page TRM / 3.3-12 Page TRM / 3.3-13 Effective Date 03/27/2008 10/04/2002 08/31/1998 01/28/2005 06/25/2002 04/02/1999 03/27/2008 03/22/2006 03/27/2008 11/15/2004 03/27/2008 11/15/2004 11/15/2005 01/10/2007 04/12/2007 03/15/2002 11/30/2005 10/31/2007 08/31/1998 03/22/2006 03/27/2008 02/18/1999 02/18/1999 07/07/1999 03/17/2008 07/16/1999 10/31/2007 08/31/1998 10/31/2007 08/31/1998 04/12/2007 12/17/1998 10/31/2007 06/02/2005 05/30/2006 03/30/2001 09/13/2005 3.2 3.3 SUSQUEHANNA - UNIT 1 TRM / LOES-1 EFFECTIVE DATE 03/27/2008
SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 45 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)
Section i Title 3.4 3.5 Page TRM / 3.3-14 Page TRM / 3.3-15 Page TRM / 3.3-16 Page TRM / 3.3-17 Page TRM / 3.3-18 Pages TRM / 3.3-19 through TRM /3.3-21 Page TRM / 3.3-22 Page TRM / 3.3-22a Pages TRM / 3.3-22b through TRM / 3.3-22d Page TRM / 3.3-23 Pages TRM / 3.3-24 and TRM / 3.3-25 Page TRM / 3.3-26 REACTOR COOLANT SYSTEM Page TRM / 3.4-1 Pages 3.4-2 through 3.4-5 Pages 3.4-6 through 3.4-9 Page TRM / 3.4-10 Page TRM / 3.4-11 Page TRM / 3.4-12 Page TRM / 3.4-13 EMERGENCY CORE COOLING AND RCIC Page TRM / 3.5-1 Pages 3.5-2 and 3.5-3 Pages TRM / 3.5-4 and TRM / 3.5-5 Pages 3.5-6 and 3.5-7 CONTAINMENT Pages 3.6-1 through 3.6-3 Page TRM / 3.6-4 Page 3.6-5 Pages TRM / 3.6-6 through TRM / 3.6-8 PLANT SYSTEMS Pages 3.7-1 through 3.7-3 Pages TRM / 3.7-4 and TRM / 3.7-5 Pages TRM / 3.7-6 through TRM / 3.7-8 Page TRM / 3.7-9 Page TRM / 3.7-10 Page TRM /3.7-11 Pages TRM / 3.7-12 and TRM / 3.7.13 Page TRM / 3.7-14 Pages TRM / 3.7-15 and TRM / 3.7-16 Page TRM / 3.7-17 Effective Date 12/14/1998 10/22/2003 06/27/2001 06/14/2002 10/31/2007 10/22/2003 03/27/2008 11/15/2004 03/22/2006 12/03/2004 05/16/2003 10/22/2003 03/31/2006 10/23/1009 08/31/1998 10/31/2007 08/31/1998 03/27/2008 03/31/2006 01/28/2005 08/31/1998 10/31/2007 08/31/1998 08/31/1998 01/07/2002 08/31/1998 12/31/2002 08/31/1998 03/31/2006 08/02/1999 03/31/2006 08/16/2005 12/29/1999 08/02/1999 08/09/2005 08/02/1999 03/31/2006 3.6 3.7 SUSQUEHANNA - UNIT 1 TRM / LOES-2 EFFECTIVE DATE 03/27/2008
SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 45 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)
Section Title Effective Date Page TRM / 3.7-18 Page TRM / 3.7-19 Pages TRM / 3.7-20 through TRM / 3.7-22 Pages TRM / 3.7-23 and TRM / 3.7-24 Pages TRM / 3.7-25 and TRM 3.7-26 Page TRM 3.7-27 Page TRM / 3.7-28 Page TRM / 3.7r29 Page TRM / 3.7-30 Pages TRM / 3.7-31 and TRM / 3.7-32 Page TRM / 3.7-33 Page TRM / 3.7-34 Page TRM / 3.7-34a Page TRM / 3.7-35 Pages TRM / 3.7-36 and TRM / 3.7-i37 Pages 3.7-38 and 3.7-39 Page TRM / 3.7-40 Pages TRM / 3.7-41 and TRM /.7-41a Page TRM / 3.7-42 Page 3.7-43 Pages TRM / 3.7-44 through TRM /13.7-46 Page TRM / 3.7-47 Page TRM / 3.7-48 Page TRM / 3.7-49 Page TRM / 3.7-50 Page TRM / 3.7-51 Page TRM / 3.7-52 Page TRM / 3.7-53 Page TRM / 3.7-54 ELECTRICAL POWER Page TRM / 3.8-1 Pages TRM / 3.8-2 through TRM / 3.8-4 Pages TRM / 3.8-5 and TRM / 3.8-6 Page TRM / 3.8-7 Pages TRM / 3.8-8 through TRM / 3.8-10 Page TRM / 3.8-11 Page TRM / 3.8-12 Pages 3.8-13 and 3.8-14 Pages TRM / 3.8-15 through TRM /3.8-17 Page 3.8-18 Page TRM / 3.8-19 Page 3.8-20 Pages TRM / 3.8-21 through TRM / 13.8-23 Pages 3.8-24 and 3.8-25 Pages TRM / 3.8-26 through TRM /3.8-29 08/02/1999 03/31/2006 08/02/1999 03/31/2006 08/02/1999 10/31/2007 11/29/2006 08/09/2005 08/25/2005 11/16/2001 01/09/2004 11/16/2001 10/05/2002 03/31/2006 02/01/1999 08/31/1998 03/31/2006 02/14/2005 01/30/2008 08/31/1998 10/05/2006 06/07/2007 10/05/2006 06/07/2007 03/09/2001 08/16/2006 12/03/2004 04/15/2003 07/29/1999 04/02/2002 01/28/2005 04/02/2002 10/31/2007 12/03/2004 09/03/2004 12/03/2004 08/31/1998 04/02/2002 08/31/1998 04/02/2002 08/31/1998 06/06/1999 08/31/1998 11/29/2006 3.8 SUSQUEHANNA - UNIT 1 TRM / LOES-3 EFFECTIVE DATE 03/27/2008
SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 45 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)
Section Title Effective Date 3.9 REFUELING OPERATIONS Pages 3.9-1 through 3.9-3 3.10 3.11 MISCELLANEOUS Page TRM / 3.10-1 Pages 3.10-2 and 3.10-3 Pages 3.10-2 and 3.10-3 Page TRM / 3.10-4 Pages TRM / 3.10-5 and TRM / 3.10-6 Page TRM / 3.10-7 RADIOACTIVE EFFLUENTS Page TRM / 3.11-1 Pages 3.11-2 and 3.11-3 Page TRM / 3.11-4 Page 3.11-5 Page TRM / 3.11-6 Pages TRM / 3.11-7 through TRM / 3.11-9 Page TRM / 3.11-10 Pages 3.11-11 and 3.11-12 Page TRM / 3.11-13 Page TRM / 3.11-14 Pages 3.11-15 and 3.11-16 Page TRM / 3.11-17 Page 3.11-18 Page TRM / 3.11-19 Pages TRM / 3.11-20 and TRM / 3.11-21 Page TRM / 3.11-22 Page TRM / 3.11-23 Page TRM / 3.11-24 Page TRM / 3.11-25 Pages TRM / 3.11-26 through TRM / 3.11-28 Page TRM / 3.11-29 Pages TRM / 3.11.30 through TRM / 3.11.32 Page TRM / 3.11-33 Page 3.11-34 Page TRM / 3.11-35 Pages TRM / 3.11-36 through TRM / 3.11-39 Pages 3.11-40 through 3.11-43 Page TRM / 3.11-44 Page TRM / 3.11-45 Page 3.11-46 Page TRM / 3.11-47 08/31/1998 03/31/2006 08/31/1998 08/31/1998 08/01/2006 03/22/2006 03/31/2006 03/31/2006 08/31/1998 03/31/2006 08/31/1998 03/31/2006 08/31/1998 12/03/2004 08/31/1998 04/12/2007 12/03/2004 09/01/1998 03/31/2006 08/31/1998 08/15/2005 03/31/2006 04/02/2002 11/14/2006 05/13/2005 04/12/2007 01/21/2004 12/03/2004 01/21/2004 03/31/2006 08/31/1998 03/31/2006 11/30/2005 08/31/1998 08/01/2006 03/31/2006 08/31/1998 03/31/2006 SUSQUEHANNA - UNIT 1 TRM / LOES-4 EFFECTIVE DATE 03/27/2008
SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 45 LIST OF!EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)
Section Title Effective Date 3.12 LOADS CONTROL PROGRAM I
Pages TRM / 3.12-1 through TRM / 3.12-3 Page TRM / 3.12-4 Page TRM / 3.12-5 02/05/1999 03/14/2008 02/05/1999 08/31/1998 4.0 ADMINISTRATIVE CONTROLS Pages 4.0-1 through 4.0-8 SUSQUEHANNA -UNIT 1 TRM / LOES-5 EFFECTIVE DATE 03/27/2008
SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 45 LIST OFEFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)
Section Title B 3.0 B3.1 B 3.2 B 3.3 APPLICABILITY BASES Pages TRM / B 3.0-1 through TRM / B 3.0-3 Page TRM / B 3.0-4 Pages TRM / B 3.0-5 and TRM / B 3.0-6 Page TRM / B 3.0-7 Pages TRM / B 3.0-8 through TRM / B 3.0-10 Pages TRM / B 3.0-11 and TRM / B 3.0-12 Pages TRM / B 3.0-13 and TRM / B 3.0-14 Page TRM / B 3.0-15 REACTIVITY CONTROL SYSTEMS BASES Page TRM / B 3.1-1 Pages TRM / B 3.1-2 and TRM / B 3.1-3 Page B 3.1-4 Page TRM / B 3.1-5 Pages TRM / B 3.1-6 and TRM / B 3.1-7 Page TRM / B 3.1-8 CORE OPERATING LIMITS BASES Page B 3.2-1 INSTRUMENTATION BASES Page TRM / B 3.3-1 Pages TRM / B 3.3-2 and TRM / B 3.3-2a Pages TRM / B 3.3-3 and TRM / B 3.3-3A Pages TRM / B 3.3-4 and TRM / B 3.3-5 Pages TRM / B 3.3-6 through TRM / B 3.3-9 Page B 3.3-10 Pages TRM / B 3.3-11 and TRM / B 3.3-12 Page TRM/ B 3.3-13 Page TRM / B 3.3-14 Page TRM / B 3.3-14a Page TRM / B 3.3-14b Pages TRM / B 3.3-15 and TRM / B 3.3-16 Page TRM / B 3.3-17 Pages TRM / B 3.3-17a through TRM / B 3.3-17c Page TRM / B 3.3-17d Pages TRM / B 3.3-17e and TRM / B 3.3-17f Pages TRM / B 3.3-18 and TRM / B 3.3-19 Page TRM / B 3.3-20 Page TRM / B 3.3-21 REACTOR COOLANT SYSTEM BASES Pages B 3.4-1 through B 3.4-3 Pages TRM / B 3.4-4 and TRM / B 3.4-4a Page TRM / B 3.4-5 Page B 3.4-6 Effective Date 08/31/1998 01/10/2007 08/31/1998 04/12/2007 08/31/1998 03/15/2002 11/30/2005 03/15/2002 07/13/1999 10/31/2007 08/31/1998 11/15/2005 03/22/2006 02/18/1999 08/31/1998 04/07/2000 10/31/2007 10/31/2007 05/30/2006 10/31/2007 08/31/1998 09/13/2005 12/03/2004 06/25/2002 10/31/2007 10/31/2007 10/22/2003 03/22/2006 03/22/2006 03/27/2008 03/22/2006 05/16/2003 10/22/2003 05/16/2003 B 3.4 08/31/1998 10/31/2007 10/15/1999 08/31/1998 SUSQUEHANNA - UNIT 1 TRM / LOES-6 EFFECTIVE DATE 03/27/2008 SUSQUEHANNA - UNIT 1 TRM / LOES-6 EFFECTIVE DATE 03/27/2008
SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 45 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)
'Section Title Effective Date B 3.5 B 3.6 B 3.7 ECCS AND RCIC BASES Pages B 3.5-1 and B 3.5-2 Pages TRM / B 3.5-3 through TRM / B 3.5-5 CONTAINMENT BASES Page TRM / B 3.6-1 Page TRM / B 3.6-2 Page B 3.6-3 Page TRM / B 3.6-4 Page TRM / B 3.6-5 Page TRM / B 3.6-6 Pages B.3.6-7 through TRM / B 3.6-11 PLANT SYSTEMS BASES Pages B 3.7-1 and B 3.7-2 Pages TRM / B 3.7*3 and TRM / B 3.7-3a Page TRM / B 3.7-4 Page TRM / B 3.7-5 Page TRM / B 3.7-6 Pages TRM / B 3.7-7 and TRM / B 3.7-7a Page TRM / B 3.7-8 Page TRM / B 3.7-9 Page TRM / B 3.7-10 Page TRM / B 3.7-10a Page TRM / B 3.7-11 Page TRM / B 3.7-11a Pages TRM / B 3.7-12 through TRM / B 3.7-14 Page TRM / B 3.7-14a Page TRM / B 3.7-14b Pages TRM / B 3.7-15 and TRM / B 3.7-16 Pages B 3.7-17 through B 3.7-20 Pages TRM / B 3.7-21 and TRM / B 3.7-21a Page TRM / B 3.7-22 and TRM / B 3.7-23 Pages TRM / B 3.7-24 through TRM / B 3.7-28 Pages TRM / B 3.7-29 and TRM / B 3.7-30 Pages TRM / B 3.7-30a and TRM / B 3.7-30b Page TRM / B 3.7-31 Page TRM / B 3.7-32 Page TRM / B 3.7-33 Page TRM / B 3.7-34 Page TRM / B 3.7-35 08/31/1998 10/31/2007 07/26/2001 02/01/1999 08/31/1998 03/27/2008 04/04/2007 12/03/2004 12/31/2002 08/31/1998 12/27/2007 03/31/2006 08/02/1999 03/31/2006 08/02/1999 08/02/1999 03/31/2006 08/02/1999 03/31/2006 08/02/1999 03/31/2006 08/02/1999 08/02/1999 01/09/2004 02/01/1999 08/31/1998 02/14/2005 01/30/2008 10/05/2006 06/07/2007 10/05/2006 12/03/2004 03/09/2001 04/15/2003 12/03/2004 07/05/2000 SUSQUEHANNA - UNIT 1 TRM / LOES-7 EFFECTIVE DATE 03/27/2008
SUSQUEHANNA STEAM ELECTRIC STATION PPL Rev. 45 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)
Section Title Effective Date B 3.8 B.3.9 ELECTRICAL POWER BASES Page TRM / B 3.8-1 Pages TRM / B 3.8-2 and TRM / B 3.8-2a Page TRM / B 3.8-3 Page TRM / B 3.8-3a Page TRM / B 3.8-4 Page TRM / B 3.8-4a Page TRM / B 3.8-5 Pages TRM / B 3.8-6 through TRM / B 3.8-16 Page TRM / B 3.8-17 Pages TRM / B 3.8-18 through TRM / B 3.8-24 REFUELING OPERATIONS BASES Pages B 3.9-1 through B 3.9-7 04/02/2002 01/28/2005 04/02/2002 04/02/2002 08/10/2004 04/02/2002 08/31/1998 04/02/2002 01/28/2005 11/29/2006 08/31/1998 08/31/1998 03/22/2006 08/23/1999 B 3.10 MISCELLANEOUS BASES Page B 3.10-1 Pages TRM / B 3.10-2 and TRM / B 3.10-3 Pages TRM / B 3.10-4 and TRM / B 3.10-5 B 3.11 RADIOACTIVE EFFLUENTS BASES Pages B 3.11-1 through B 3.11-9 Page TRM / B 3.11-10 Pages TRM/B 3.11-11 and TRM/B 3.11-11a Pages TRM/B 3.11-12 and TRM/B 3.11-13 Page TRM / B 3.11-14 Page TRM / B 3.11-15 Pages B 3.11-16 through B 3.11-19 Page TRM / B 3.11-20 Page TRM / B 3.11-20a Page TRM / B 3.11-21 Pages TRM / B 3.11-22 and TRM / B 3.11.23 Page TRM / B 3.11.23a Pages TRM / B 3.11-24 and TRM / B 3.11-25 Pages B 3.11-26 and B 3.11-27 Pages TRM / B 3.11-28 and TRM / B 3.11-29 Page TRM / B 3.11-30 Pages B 3.7-31 through B 3.7-35 Page TRM / B 3.11-36 B.3.12 LOADS CONTROL PROGRAM BASES Page TRM / B 3.12-1 Pages TRM / B 3.12-2 and TRM / B 3.12-3 08/30/1998 02/01/1999 04/07/2000 02/01/1999 12/03/2004 02/01/1999 08/30/1998 04/02/2002 04/02/2002 05/13/2005 11/14/2006 05/13/2005 01/21/2004 08/30/1998 11/30/2005 12/03/2004 08/30/1998 02/12/1999 09/19/2007 02/05/1999 TRM1 text LOES 04/08/2008 SUSQUEHANNA - UNIT 1 TRM / LOES-8 EFFECTIVE DATE 03/27/2008
Instrument Trip Setpoint Program PPL Rev. 6 2.2 2.0 PLANT PROGRAMS AND SETPOINTS 2.2 Instrument Trip Setpoint Table The Instrument Trip Setpoint Limits in Table 2.2-1 are the Trip Setpoint value limits that were contained in the Instrumentation Setpoint tables for protection systems and other functions important to safety that were included in the scope of the original Standard Technical Specifications. Actual instrument setpoints are established utilizing the Allowable Values specified in the Technical Specifications and Technical Requirements. Allowable Values are established in the Reference LCOs and TROs identified in this Table. TRO references are enclosed in square brackets.
Instrumentation process setpoints for the listed subsystems and trip functions are set consistent with the Trip Setpoint Limit Column of Table 2.2-1. Actual setpoints are established in accordance with engineering procedures.
Alarm setpoints and other non-protection system trip settings as may be found in the Technical Specifications or in the Technical Requirements are not included in this table.
Reference NDAP-QA-1104 Setpoint Change Control SUSQUEHANNA - UNIT 1 TRM / 2.0-5 EFFECTIVE DATE 04/02/1999
Instrument Trip-Setpoint Program 2.2 PPL Rev. 6 TABLE 2.2-1 (Page 1 of 8)
INSTRUMENTATION SETPOINTS SYSTEM/REFERENCE LCO [TRO]
TRIP FUNCTION TRIP SETPOINT 2.2.1 Reactor Protection 2.2.1.1 3.3.1.1 Intermediate Range Monitor, Neutron Flux -
< 120/125 divisions of full scale High 2.2.1.2 3.3.1.1 Average Power Range Monitor, Neutron Flux
< 18% of RATED THERMAL POWER
- High (Setdown) 2.2.1.3 3.3.1.1 Average Power Range Monitor, Simulated 0.55 W+ 58.7%
Thermal Power - High, Two Loop Operation 2.2.1.4 3.3.1.1 Average Power Range Monitor, Simulated 0.55 (W-AW) + 5 8.7 %(b)
Thermal Power - High, Single Loop Operation 2.2.1.5 3.3.1.1 Average Power Range Monitor, Simulated
- 113.5% of RATED THERMAL Thermal Power - High, Clamp POWER 2.2.1.6 3.3.1.1 Average Power Range Monitor, Neutron Flux-
- _ 118% of RATED THERMAL High POWER 2.2.1.7 3.3.1.1 Reactor Vessel Steam Dome Pressure - High
- 1087 psig 2.2.1.8 3.3.1.1 Reactor Vessel Water Level - Low, Level 3
>13.0 inches (a) 2.2.1.9 3.3.1.1 Main Steam Isolation Valve - Closure
< 10% closed 2.2.1.10 This Section Not Used 2.2.1.11 3.3.1.1 Drywell Pressure - High
- < 1.72 psig 2.2.1.12 3.3.1.1 Scram Discharge Volume Water Level - High -
- 65 gallons Level Transmitter 2.2.1.13 3.3.1.1 Scram Discharge Volume Water Level - High -
< 61 gallons Float Switch 2.2.1.14 3.3.1.1 Turbine Stop Valve - Closure
< 5.5% closed 2.2.1.15 3.3.1.1 Turbine Control Valve Fast Closure, Trip
> 500 psig Oil Pressure - Low (continued)
(a) See Figure 2.2-1 (b) For Single loop operation, the value of AW = 8.7 SUSQUEHANNA - UNIT 1 TRM /2.,0-6 EFFECTIVE DATE 03/27/2008
Instrument Trip Setpoint Program 2.2 PPL Rev. 6 TABLE 2.2-1 (Page 2 of 8)
INSTRUMENTATION SETPOINTS SYSTEM/REFERENCE LCO [TRO]
TRIP FUNCTION TRIP SETPOINT 2.2.1.16 OPRM Instrumentation 2.2.1.16.1 3.3.1.1 Sp PBA Amplitude Trip See COLR -TRO 3.2 2.2.1.16.2 3.3.1.1 Np PBA Successive Confirmation Count Trip See COLR - TRO 3.2 2.2.1.16.3
[3.3.9]
TOL (E) Period Tolerance 0.10 sec 2.2.1.16.4
[3.3.9]
fc Conditioning Filter Cutoff Frequency 1.50 Hz 2.2.1.16.5
[3.3.9]
Tmin Oscillation Period Lower Time Limit 1.00 sec 2.2.1.16.6
[3.3.9]
Tmax Oscillation Period Upper Time Limit 3.50 sec 2.2.1.16.7
[3.3.9]
LPRMmin Minimum LRPMs/Cell Required for 2
Cell Operability 2.2.1.16.8
[3.3.9]
S1 Peak Threshold Setpoint/ABA & GRBA 1.20 2.2.1.16.9
[3.3.9]
S2 Valley Threshold Setpoint/ABA & GRBA 0.85 2.2.1.16.10
[3.3.9]
Smax Amplitude Trip Setpoint/ABA 1.50 2.2.1.16.11
[3.3.9]
DR3 Growth Rate Factor Setpoint/GRBA 1.60 2.2.2 Isolation Actuation Instrumentation 2.2.2.1 Primary Containment Isolation 2.2.2.1.1 3.3.6.1 Reactor Vessel Water Level Low, Level 3
> 13.0 inches(a) 2.2.2.1.2 3.3.6.1 Reactor Vessel Water Level Low Low, Level 2
> -38.0 inches(a) 2.2.2.1.3 3.3.6.1 Reactor Vessel Water Level Low Low Low,
> -129 inches(a)
Level 1 2.2.2.1.4 3.3.6.1 Drywell Pressure - High
< 1.72 psig 2.2.2.1.5 3.3.6.143.3.6]
SGTS Exhaust Radiation - High
- 23.0 mR/hr 2.2.2.1.6
[3.3.6]
Main Steam Line Radiation - High High
< 15 x full power background without hydrogen injection (continued)
(a) See Figure 2.2-1 SUSQUEHANNA - UNIT 1 TRM / 2.0-7 EFFECTIVE DATE 03/22/2006
Instrument Trip Setpoint Program 2.2 PPL Rev. 6 TABLE 2.2-1 (Page 3 of 8)
INSTRUMENTATION SETPOINTS SYSTEM/REFERENCE LCO
[TRO]
TRIP FUNCTION TRIP SETPOINT 2.2.2.2 2.2.2.2.1 2.2.2.2.2 2.2.2.2.3 2.2.2.2.4 2.2.2.2.5 2.2.2.3 2.2.2.3.1 2.2.2.3.2 2.2.2.3.3 2.2.2.3.4 2.2.2.3.5 2.2.2.3.6 2.2.2.3.7 2.2.2.3.8 2.2.2.4 2.2.2.4.1 2.2.2.4.2 2.2.2.4.3 2.2.2.4.4 2.2.2.4.5 2.2.2.4.6 2.2.2.4.7 2.2.2.4.8 2.2.2.4.9 Secondary Containment Isolation 3.3.6.2 3.3.6.2 3.3.6.2 3.3.6.2 3.3.6.2 Reactor Vessel Water Level - Low Low, Level 2 Drywell Pressure - High Refuel Floor High Exhaust Duct Radiation -
High Railroad Access Shaft Exhaust Duct Radiation - High Refuel Floor Wall Exhaust Duct Radiation -
High
> -38.0 inches(a)
- 1.72 psig
- 18 mR/hr
< 5 mR/hr
< 21 mR/hr Main Steam Line Isolation 3.3.6.1 3.3.6.1 3.3.6.1 3.3.6.1 3.3.6.1
[3.3.6]
[3.3.6]
Reactor Water Cleanup System 3.3.6.1 3.3.6.1 3.3.6.1 3.3.6.1
[3.3.6]
3.3.6.1
[3.3.6]
3.3.6.1
[3.3.6]
Reactor Vessel Water Level - Low Low Low, Level 1 Main Steam Line Pressure - Low Main Steam Line Flow - High Condenser Vacuum - Low Reactor Building Main Steam Line Tunnel Temperature - High This Section Not Used Reactor Building Main Steam Line Tunnel A Temperature - High Turbine Building Main Steam Tunnel Temperature - High Isolation Reactor Vessel Water Level - Low Low, Level 2 RWCU A Flow - High RWCU Flow - High RWCU Penetration Area Temperature - High RWCU Penetration Room Area A Temperature
- High RWCU Pump Area Temperature - High RWCU Pump Room Area A Temperature -
High RWCU Heat Exchanger Area Temperature -
High RWCU Heat Exchanger Room Area A Temperature - High
_>-129 inches(a)
> 861 psig
< 173 psid
> 9.0 inches Hg vacuum
< 1770F
< 99°F
< 197°F
>-38 inches(a)
< 59 gpm
< 462 gpm
< 1310F
<690F
< 147°F
_< 69°F
< 147°F
< 69°F (continued)
(a) See Figure 2.2-1 SUSQUEHANNA - UNIT 1 TRM / 2.0-8 EFFECTIVE DATE 03/27/2008
PPL Rev. 6 Instrument Trip Setpoint Program 2.2 TABLE 2.2-1 (Page 4 of 8)
INSTRUMENTATION SETPOINTS SYSTEM/REFERENCE LCO
[TRO]
TRIP FUNCTION TRIP SETPOINT 2.2.2.5 Reactor Core Isolation Cooling System Isolation 2.2.2.5.1 3.3.6.1 RCIC Steam Line A Pressure - High 2.2.2.5.2 3.3.6.1 RCIC Steam Supply Line Pressure - Low 2.2.2.5.3 3.3.6.1 RCIC Turbine Exhaust Diaphragm Pressure
- High 2.2.2.5.4 3.3.6.1 RCIC Equipment Room Temperature - High 2.2.2.5.5 3.3.6.1 RCIC Pipe Routing Area Temperature - High 2.2.2.5.6 3.3.6.1 RCIC Emergency Area Cooler Temperature -
High 2.2.2.5.7 3.3.6.1 Drywell Pressure - High 2.2.2.5.8
[3.3.6]
RCIC Equipment Room A Temperature - High 2.2.2.5.9
[3.3.6]
RCIC Pipe Routing Area A Temperature -
High 2.2.2.6 High Pressure Coolant Injection System Isolation
< 188 inches H 20
_> 60 psig
- 10.0 psig
< 167°F
< 167°F
< 1670F
< 1.72 psig
< 89OF
< 89OF 2.2.2.6.1 2.2.2.6.2 2.2.2.6.3 2.2.2.6.4 2.2.2.6.5 2.2.2.6.6 2.2.2.6.7 2.2.2.6.8 2.2.2.6.9 3.3.6.1 3.3.6.1 3.3.6.1 3.3.6.1 3.3.6.1 3.3.6.1 3.3.6.1
[3.3.6]
[3.3.6]
HPCI Steam Line A Pressure - High HPCI Steam Supply Line Pressure - Low HPCI Turbine Exhaust Diaphragm Pressure -
High HPCI Equipment Room Temperature - High HPCI Emergency Area Cooler Temperature -
High HPCI Pipe Routing Area Temperature - High Drywell Pressure - High HPCI Equipment Room A Temperature - High HPCI Pipe Routing Area A Temperature -
High ition Reactor Vessel Water Level - Low, Level 3 Reactor Vessel Steam Dome Pressure - High RHR Flow - High 2.2.2.7 Shutdown Cooling/System Isola
_ 370 inches H 20
> 104 psig
< 10 psig
< 167°F
< 167OF
< 167OF
< 1.72 psig
< 89OF
< 89 0F
> 13.0 inches(a)
< 98 psig
< 25,000 gpm
_>-129 inches(a)
< 1.72 psig
> 413, < 427 psig 2.2.2.7.1 2.2.2.7.2 2.2.2.7.3 2.2.3 3.3.6.1 3.3.6.1
[3.3.6]
ECCS Actuation 2.2.3.1 Core Spray System 2.2.3.1.1 3.3.5.1 2.2.3.1.2 2.2.3.1.3 3.3.5.1 3.3.5.1 Reactor Vessel Water Level - Low Low Low, Level 1 Drywell Pressure - High Reactor Vessel Steam Dome Pressure - Low injection permissive (continued)
(a) See Figure 2.2-1 SUSQUEHANNA - UNIT 1 TRM / 2.0-9 EFFECTIVE DATE 11/15/2004
Instrument Trip Setpoint Program 2.2 PPL Rev. 6 TABLE 2.2-1 (Page 5 of 8)
INSTRUMENTATION SETPOINTS 2.2.3.2 2.2.3.2.1 2.2.3.2.2 2.2.3.2.3 2.2.3.2.4 2.2.3.3 2.2.3.3.1 2.2.3.3.2 2.2.3.3.3 2.2.3.3.4 2.2.3.4 2.2.3.4.1 2.2.3.4.2 2.2.3.4.3 2.2.3.4.4 2.2.3.4.5 2.2.3.4.6 2.2.3.4.7 2.2.3.5 2.2.3.5.1 2.2.3.5.1.1 2.2.3.5.1.2 SYSTEM/REFERENCE LCO
[TRO]
LPCI Mode of RHR System 3.3.5.1 3.3.5.1 3.3.5.1 3.3.5.1 TRIP FUNCTION TRIP SETPOINT Reactor Vessel Water Level - Low Low Low, Level 1 Drywell Pressure - High Reactor Vessel Steam Dome Pressure - Low, injection permissive Reactor Vessel Steam Dome Pressure - Low, Recirculation Discharge Valve permissive
>-129 inches(a)
< 1.72 psig
>413, <427 psig
>236 psig, decreasing HPCI System 3.3.5.1 Reactor Vessel Water Level - Low Low, Level 2 3.3.5.1 Drywell Pressure - High 3.3.5.1
- Condensate Storage Tank Level - Low 3.3.5.1 Reactor Vessel Water Level - High, Level 8 Automatic Depressurization System (ADS) 3.3.5.1 Reactor Vessel Water Level - Low Low Low, Level 1 3.3.5.1 Drywell Pressure - High 3.3.5.1 ADS Timer 3.3.5.1 Core Spray Pump Discharge Pressure - High 3.3.5.1 Low Pressure Coolant Injection Pump Discharge Pressure - High 3.3.5.1 Reactor Vessel Water Level - Low, Level 3 Confirmatory 3.3.5.1 ADS Drywell Pressure Bypass Timer Loss of Power - ECCS Actuation 4.16kv ESS Bus Undervoltage (Loss of Voltage < 20%).
3.3.8.1 Bus Undervoltage 3.3.8.1 Time delay
Ž-38 inchesla)
- ý 1.72 psig
Ž36.0 inches above tank bottom
- 54 inches
Ž-129 inches
- 1.72 psig
- 102 seconds
>135, <155 psig
>121, 129 psig
Ž13 inches
- 420 seconds
>823.2, <ý856.8 Volts
>0.4, <ý0.6 seconds (continued)
(a) See Figure 2.2-1 SUSQUEHANNA - UNIT 1 TRM / 2.0-10 EFFECTIVE DATE 11/15/2004
Instrument Trip Setpoint Program 2.2 PPL.Rev. 6 TABLE 2.2-1 (Page 6 of 8)
INSTRUMENTATION SETPOINTS 2.2.3.5.2 2.2.3.5.2.1 2.2.3.5.2.2, 2.2.3.5.23 2.2.3.5.3.1 2.2.3.5.3.2 2.2.3.5.3.4 2.2.3.5.4 2.2.3.5.4.1 2.2.3.5.4.2 2.2.3.5.5 2.2.3.5.5.1 2.2.3.5.5.2 2.2.4 2.2.4.1 2.2.4.1 2.2.5 2.2.5.1 2.2.5.2 2.2.6 2.2.6.1 2.2.6.2 2.2.6.3 SYSTEM/REFERENCE LCO
[TRO]
TRIP FUNCTION 4.16kV ESS Bus Undervoltage (Degraded Voltage < 65%)
3.3.8.1 Bus Undervoltage 3.3.8.1 Time delay 4.16kV ESS Bus Undervoltage (Degraded Voltage, < 93%)
3.3.8.1 Bus Undervoltage 3.3.8.1 Time Delay (Non-LOCA) 3.3.8.1 Time Delay (LOCA) 480V ESS Bus 0B565 Undervoltage (Degraded Voltage, < 65%)
[3.8.5]
480V Basis
[3.8.5]
Time Delay 480V ESS Bus 0B565 Undervoltage (Degraded Voltage, < 92%)
[3.8.5]
480V Basis
[3.8.5]
Time Delay ATWS Alternate Rod Injection and Recirculation Pump Trip 3.3.4.2/[3.1.1]
Reactor Vessel, Water Level - Low Low, Level 2
.3.3.4.2/3.1.1]
Reactor Vessel Steam Dome Pressure - High End of Cycle Recirculation Pump Trip 3.3.4.1 Turbine Stop Valve-Closure 3.3.4.1 Turbine Control Valve - Fast Closure Reactor Core Isolation Cooling System Actuation 3.3.5.2 Reactor Vessel Water Level - Low Low, Level 2 3.3.5.2 Reactor Vessel Water Level - High, Level 8 3.3.5.2 Condensate Storage Tank Level - Low TRIP SETPOINT
> 2641.1, <2748.9 Volts
>2.7, < 3.3 seconds
>_ 3829.3, < 3906.7 Volts
> 4 minute, 30 seconds
< 5 minute, 30 seconds
> 9, _< 11 seconds
> 308.9, < 315.1 Volts
> 4.5, <5.5 seconds
> 437.6, <446.4 Volts
>_ 9, <11 seconds
>-38 inches(a)
< 1135 psig
< 5.5% closed
>_ 500 psig
>-38 inches(a)
< 54 inches(a)
> 36.0 inches above tank bottom (continued)
(a) See Figure 2.2-1 SUSQUEHANNA - UNIT 1 TRM / 2.0-11 EFFECTIVE DATE 11/15/2004
PPL Rev. 6 Instrument Trip Setpoint Program 2.2 TABLE 2.2-1 (Page 7 of 8)
INSTRUMENTATION SETPOINTS SYSTEM/REFERENCE LCO
[TRO]
TRIP FUNCTION TRIP SETPOINT 2.2.7 Control Rod Block 2.2.7.1 Rod Block Monitor 2.2.7.1.1 2.2.7.1.2 3.3.2 3.3.2 3.3.2 3.3.2 3.3.2 3.3.2 Low Power Range - Upscale Intermediate Power Range - Upscale High Power Range - Upscale Low Power Range Setpoint Intermediate Power Range Setpoint High Power Range Setpoint See COLR TRO 3.2 See COLR TRO 3.2 See COLR TRO 3.2 See COLR TRO 3.2 See COLR TRO 3.2 See COLR TRO 3.2 2.2.7.2 APRM 2.2.7.2.1 2.2.7.2.2 2.2.7.2.3 2.2.7.2.4 2.2.7.2.5
[3.1.3]
[3.1.3]
[3.1.3]
[3.1.3]
[3.1.3]
Simulated Thermal Power-High
- Two Loop Operation Simulated Thermal Power-High
- Single Loop Operation Simulated Thermal Power-High - Clamp Downscale Neutron Flux - High (Setdown) 0.55W + 54.2%
0.55 (W-AW) + 54.2% (c)
_<.108% of RATED THERMAL POWER
>_ 5% of RATED THERMAL POWER
< 12% of RATED THERMAL POWER 2.2.7.3 Source Range Monitors 2.2.7.3.1 2.2.7.3.2 2.2.7.4 2.2.7.4.1 2.2.7.4.2
[3.1.3]
[3.1.3]
Intermediate Range Monitors Upscale Downscale Upscale Downscale
< 2E5 cps
> 3.0 cps(b)
< 108/125 divisions of full scale
> 5/125 divisions of full scale
[3.1.3]
[3.1.3]
2.2.7.5 Scram Discharge Volume 2.2.7.5.1
[3.1.3]
Water Level - High
< 35.9 gallons 2.2.7.6 Reactor Coolant System Recirculation Flow 2.2.7.6.1
[3.1.3]
Upscale 114%
(continued)
(b) With a signal-to-noise ratio >2, or within the limits of Figure 2.2-2.
(c) For single loop operation, the value of AW = 8.7 SUSQUEHANNA - UNIT 1 TRM / 2.0-12 EFFECTIVE DATE 03/27/2008
Instrument Trip Setpoint Program 2.2 PPL Rev.,6 TABLE 2.2-1 (Page 8 of 8)
INSTRUMENTATION SETPOINTS SYSTEM/REFERENCE LCO
[TRO]
TRIP FUNCTION TRIP SETPOINT 2.2.8 CREOASS 2.2.8.1 3.3.7.1 Main Control Room Outside Air Intake
< 5 mR/hr Radiation Monitor 2.2.8.1.1 3.3.7.1 Reactor Vessel Water Level - Low Low,
> -38.0 inches(a)
Level 2 2.2.8.1.2 3.3.7.1 Drywell Pressure - High
- 1.72 psig 2.2.8.1.3 3.3.7.1 Refuel Floor High Exhaust Duct Radiation
< 18 mR/hr
- High 2.2.8.1.4 3.3.7.1 Railroad Access Shaft Exhaust Duct
_5 mR/hr Radiation - High 2.2.8.1.5 3.3.7.1 Refuel Floor Wall Exhaust Duct Radiation
- 21 mR/hr
- High 2.2.9 Feedwater/Main Turbine Trip System Actuation 2.2.9.1 3.3.2.2 Reactor Vessel Level - High
- 54.0 inches(a) 2.2.10 MVP Isolation 2.2.10.1
[3.3.11]
Main Steam Line Radiation - High High
< 15 xfull power background without hydrogen injection (a) See Figure 2.2-1 SUSQUEHANNA - UNIT 1 TRM / 2.0-13 EFFECTIVE DATE 11/15/2004
Instrument Trip Setpoint Table 2.2 PPL Rev. 6 FIGURE 2.2-i REACTOR VESSEL WATERILEVEL SUSQUEHANNA - UNIT 1 TRM / 2.0-14 EFFECTIVE DATE 11/15/2004
Instrument Trip Setpoint Table PPL Rev. 6 2.2 Instrument Trip Setpoint Table 2.2 C/)
0 z
D 0
0, 3
2.8 2.6 2.4 2.2 2
1.8 1.6 1.4 1.2 1
0.8 0.6 0.4 0.2 0
Acceptable Not Acceptable
-r---
F-2 6
10 14 18 22 26 30 Signal-to-Noise Ratio Figure 2.2-2 Minimum SRM Trip Setpoint Versus Signal-to-Noise Ratio SUSQUEHANNA - UNIT 1 TRM / 2.0-15 EFFECTIVE DATE 11/15/2005
Control Rod Block Instrumentation 3.1.3 PPL Rev. 4 3.1 Reactivity Control Systems 3.1.3 Control Rod Block Instrumentation The control rod block instrumentation for each function in Table 3.1.3-1 shall be OPERABLE.
APPLICABILITY:
According to Table 3.1.3-1 ACTIONS
NOTE Separate condition entry is allowed for each channel CONDITION REQUIRED ACTION COMPLETION TIME A. One or more required A.1 Enter the Condition referenced Immediately channels inoperable, in Table 3.1.3-1for the channel.
B. As required by Required B.1 Place at least one inoperable 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> from discovery Action A.1 and referenced channel in the tripped of loss of trip in Table 3.1.3-1.
condition.
capability AND B.2 Place the inoperable channel 7 days in the tripped condition.
C. As required by Required C.1 Place the inoperable channel 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Action A.1 and referenced in the tripped condition.
in Table 3.1.3-1.
D. Required Actions and D.1 Suspend Control Rod Immediately Completion Time of withdrawal.
Conditions B or C not met.
SUSQUEHANNA - UNIT 1 3.1-5 EFFECTIVE DATE 08/31/1998
Control Rod Block Instrumentation 3.1.3 PPL Rev. 4 TECHNICAL REQUIREMENT SURVEILLANCE NOTES
- 1. Refer lto Table 3.1.3-1 to determine which TRSs apply for each Control Rod Block Function.
- 2. Neutron detectors may be excluded from CHANNEL CALIBRATION.
- 3. When a channel is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed for up to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> provided at least one other OPERABLE channel in the same trip system is monitoring that parameter.
SURVEILLANCE FREQUENCY TRS 3.1.3.1 Perform CHANNEL CHECK 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> TRS 3.1.3.2 ----------
NOTE For Function 1.a, not required to be performed when entering MODE 2 from MODE 1 until 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after entering MODE 2.
Perform CHANNEL FUNCTIONAL TEST 184 days TRS 3.1.3.3 Perform CHANNEL FUNCTIONAL TEST 7 days TRS 3.1.3.4 Perform CHANNEL FUNCTIONAL TEST 92 days TRS 3.1.3.5 Perform CHANNEL CALIBRATION 184 days NOTE Neutron detectors are excluded.
TRS 3.1.3.6 Perform CHANNEL CALIBRATION 24 months TRS 3.1.3.7 Perform LOGIC SYSTEM FUNCTIONAL TEST 24 months SUSQUEHANNA - UNIT 1 TRM / 3.1-6 EFFECTIVE DATE 03/22/2006
Control Rod Block Instrumentation 3.1.3 PPL Rev. 4 TABLE 3.1.3-1 (Page 1 of 2)
CONTROL ROD BLOCK INSTRUMENTATION APPLICABLE REQUIRED CONDITIONS MODES OR OTHER CHANNELS REFERENCED FROM SPECIFIED REQUIRED ACTION SURVEILLANCE ALLOWABLE FUNCTION CONDITIONS A.1 REQUIREMENTS VALUE
- 1. APRM
- a. Neutron Flux -
2, 5(a) 3 B
TRS 3.1.3.2
< 14% RTP I High (Setdown)
TRS 3.1.3.6
- b. Simulated Thermal 1
3 B
TRS 3.1.3.2 0.55W +
Power - High TRS 3.1.3.6 56.2%(b)
- c. Downscale 1
3 B
TRS 3.1.3.2
- d. Inop 1,2 3
B TRS 3.1.3.2 NA 5(a) 3 B
TRS 3.1.3.2 NA
- 2. Source Range Monitors
- a. Detector not full in 2(c) 3 B
- 5) 2 B
- b. Upscale 2 (d) 3 B
TRS 3.1.3.3
_< 3.3E5 cps TRS 3.1.3.6 TRS 3.1.3.7 52 B
TRS 3.1.3.3
< 3.3E5 cps TRS 3.1.3.6 TRS 3.1.3.7
- c. Inop 2(d) 3 B
- 50) 2 B
TRS 3.1.3.3 NA TRS 3.1.3.7 (continued)
(a)
(b)
(c)
(d)
(0)
When performing Shutdown Margin Demonstration per Technical Specification 3.10.8.
For single loop operation, the value of 11W = 8.7 When not automatically bypassed with SRM counts >_ 100 cps or the IRM channels on range 3 or higher.
When not automatically bypassed with IRM channels on range 8 or higher.
With any control rod withdrawn from a core cell containing one or more fuel assemblies.
SUSQUEHANNA - UNIT 1 TRM / 3.1-7 EFFECTIVE DATE 03/27/2008
Control Rod Block Instrumentation 3.1.3 PPL Rev. 4 TABLE 3.1.3-1 (Page 2 of 2)
CONTROL ROD BLOCK INSTRUMENTATION APPLICABLE REQUIRED CONDITIONS MODES OR OTHER CHANNELS REFERENCED FROM SPECIFIED REQUIRED ACTION SURVEILLANCE ALLOWABLE FUNCTION CONDITIONS A.1 REQUIREMENTS VALUE
- d. Downscale 2(e) 3 B
TRS 3.1.3.3
> 1.8 cps(f)
TRS 3.1.3.6 TRS 3.1.3.7 5(')0) 2 B
TRS 3.1.3.3
> 1.8 cps(f TRS 3.1.3.6 TRS 3.1.3.7
- a. Detector not full in 2, 50) 6 B
- b. Neutron Flux-2,50) 6 B
TRS 3.1.3.1
<110/125 High TRS 3.1.3.3 divisions of full TRS 3.1.3.5 scale TRS 3.1.3.7
- c. Inop 2, 50) 6 B
- d. Downscale 2(9) 50) 6 B
TRS 3.1.3.1 3/125 divisions TRS 3.1.3.3 of full scale TRS 3.1.3.5 TRS 3.1.3.7
- 4. Scram Discharge 1,2, 5 (h) 2 C
TRS 3.1.3.4
_< 36.5 gallons Volume Water Level -
TRS 3.1.3.6 High
- 5. Reactor Coolant System Recirculation Flow
- a. Upscale 1
3 C
TRS 3.1.3.2
- 117/125 TRS 3.1.3.6 divisions of full scale I
(e)
(0)
(g)
(h) 0I) ci)
When not automatically bypassed with IRMs on range 3 or higher.
With a signal-to-noise ratio _>2, or within the limits of TS Figure 3.3.1.2-1.
When not automatically bypassed with IRM channels on range* 1.
When more than one control rod is withdrawn. Not applicable to control rods removed per Technical Specification 3.10.5 or 3.10.6.
Not required when eight or fewer fuel assemblies (adjacent to the SRMs) are in the core.
With any control rod withdrawn from a core cell containing one or more fuel assemblies.
SUSQUEHANNA - UNIT 1 TRM / 3.1-8 EFFECTIVE DATE 03/27/2008
Core Operating Limits Report (COLR)
PPL Rev. 9 3.2.1 3.2 Core Operating Limits Report (COLR) 3.2.1 Core Operating Limits Report (COLR)
TRO 3.2.1 The Core Operating Limits specified in the attached COLR shall be met.
APPLICABILITY:
Specified in the referenced Technical Specifications.
ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Core Operating Limits not A.1 Perform action(s) described Specified in met.
in referenced Technical referenced Specification.
Technical Specifications.
TECHNICAL REQUIREMENT SURVEILLANCE SURVEILLANCE FREQUENCY N/A No associated Surveillances. Surveillances are implemented in the applicable Technical Specifications.
SUSQUEHANNA - UNIT 1 TRM / 3.2-1 EFFECTIVE DATE 7/07/1999
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 1 of 53 Susquehanna SES Unit 1 Cycle 16 CORE OPERATING LIMITS REPORT Nuclear Fuels Engineering March 2008 SUSQUEHANNA UNIT 1 TRM/3.2-2 EFFECTIVE DATE 03/17/2008
PPL Rev. 9 PL-NF-08-O01 Rev. 0 Page 2 of 53 CORE OPERATING LIMITS REPORT REVISION DESCRIPTION INDEX Rev.
Affected No.
Sections Description/Purpose of Revision 0
ALL Issuance of this COLR is in support of Unit 1 Cycle 16 operation.
FORM NFP-QA-008-2, Rev. 1 SUSQUEHANNA UNIT 1 TRM/3.2-3.
EFFECTIVE DATE 03/17/2008
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 3 of 53 SUSQUEHANNA STEAM ELECTRIC STATION Unit 1 Cycle 16 CORE OPERATING LIMITS REPORT Table of Contents 1.0 INTRO DUCTIO N....................................................................................................
4 2.0 D E FIN IT IO N S............................................................................................................
5 3.0 SHUTDOWN MARGIN...........................................................................................
6 4.0 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)
........... 7 5.0 MINIMUM CRITICAL POWER RATIO (MCPR)......................................................
9 6.0 LINEAR HEAT GENERATION RATE (LHGR).......................................................
24 7.0 ROD BLOCK MONITOR (RBM) SETPOINTS AND OPERABILITY REQ UIREM ENTS....................................................................................................
32 8.0 RECIRCULATION LOOPS - SINGLE LOOP OPERATION.................................... 34 9.0 POWER / FLOW MAP...........................................................................................
49 10.0 O PRM SETPO INTS................................................................................................
51 11.0 R EFER EN C ES............................................................................................................
52 SUSQUEHANNA UNIT 1 TRM/3.2-4 EFFECTIVE DATE 03/17/2008
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 4 of 53
1.0 INTRODUCTION
This CORE OPERATING LIMITS REPORT for Susquehanna Unit 1 Cycle 16 is prepared in accordance with the requirements of Susquehanna Unit 1, Technical Specification 5.6.5. As required by Technical Specifications 5.6.5, core shutdown margin, the core operating limits, RBM setpoints, and OPRM setpoints presented herein were developed using NRC-approved methods and are established such that all applicable limits of the plant safety analysis are met.
SUSQUEHANNA UNIT I TRMI3.2-5 EFFECTIVE DATE 03/1712008
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 5 of 53 2.0 DEFINITIONS Terms used in this COLR but not defined in Section 1.0 of the Technical Specifications or Section 1.1 of the Technical Requirements Manual are provided below.
2.1 The AVERAGE PLANAR EXPOSURE at a specified height shall be equal to the total energy produced per unit length at the specified height divided by the total initial weight of uranium per unit length at that height.
2.2 The PELLET EXPOSURE shall be equal to the total energy produced per unit length of fuel rod at the specified height divided by the total initial weight of uranium per unit length of that rod at that height.
2.3 FDLRX is the ratio of-the maximum LHGR calculated by the core monitoring system for each fuel bundle divided by the LHGR limit for the applicable fuel bundle type.
2.4 LHGRFACf is a multiplier applied to the LHGR limit when operating at less than 108 Mlbm/hr core flow. The LHGRFACf multiplier protects against both fuel centerline melting and cladding strain during anticipated system transients initiated from core flows less than 108 Mlbm/hr.
2.5 LHGRFACP is a multiplier applied to the LHGR limit when operating at less than 100%
rated power. The LHGRFACP multiplier protects against both fuel centerline melting and cladding strain during anticipated system transients initiated from partial power conditions.
2.6 MFLCPR is the ratio of the applicable MCPR operating limit for the applicable fuel bundle type divided by the MCPR calculated by the core monitoring system for each fuel bundle.
2.7 MAPRAT is the ratio of the maximum APLHGR calculated by the core monitoring system for each fuel bundle divided by the APLGHR limit for the applicable fuel bundle type.
2.8 OPRM is the Oscillation Power Range Monitor. The Oscillation Power Range Monitor (OPRM) will reliably detect and suppress anticipated stability related power oscillations while providing a high degree of confidence that the MCPR safety limit is not violated.
2.9 Np is the OPRM setpoint for the number of consecutive confirmations of oscillation half-cycles that will be considered evidence of a stability related power oscillation.
2.10
'Sp is the OPRM trip setpoint for the peak to average OPRM signal.
2.11 Fp is the core flow, in Mlbm / hr, below which the OPRM RPS trip is activated.
SUSQUEHANNA UNIT 1 TRM/3.2-6 EFFECTIVE DATE 03/17/2008
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 6 of 53 3.0 SHUTDOWN MARGIN 3.1 Technical Specification Reference Technical Specification 3.1.1 3.2 Description The SHUTDOWN MARGIN shall be equal to or greater than:
a) 0.38% Ak/k with the highest worth rod analytically determined OR b) 0.28% Ak/k with the highest worth rod determined by test Since core reactivity will vary during the cycle as a function of fuel depletion and poison bumup, Beginning of Cycle, (BOC) SHUTDOWN MARGIN (SDM) tests must also account for changes in core reactivity during the cycle. Therefore, the SDM measured at BOC must be equal to or greater than the applicable requirement from either 3.2.a or 3.2.b plus an adder, "R". The adder, "R", is the difference between the calculated value of maximum core reactivity (that is, minimum SDM) during the operating cycle and the calculated BOC core reactivity. If the value of "R" is zero (that is, BOC is the most reactive point in the cycle) no correction to the BOC measured value is required.
The SHUTDOWN MARGIN limits provided in 3.2a and 3.2b are applicable in MODES 1, 2,-3, 4, and 5. This includes core shuffling.
SUSQUEHANNA UNIT 1 TRM/3.2-7 EFFECTIVE DATE.03/17/2008
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 7 of 53 4.0 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR) 4.1 Technical Specification Reference Technical Specification 3.2.1 4.2 Description The APLHGRs for ATRIUMTM-10 fuel shall not exceed the limit shown in Figure 4.2-1.
The APLHGR limits in Figure 4.2-1 are valid for Main Turbine Bypass Operable and Inoperable, EOC-RPT Operable and Inoperable, and Backup Pressure Regulator Operable and Inoperable in Two Loop operation. The APLHGR limits for Single Loop operation are provided in Section 8.0.
SUSQUEHANNA UNIT 1 TRM/3.2-8 EFFECTIVE DATE 03/17/2008
a c-fl Cam
>1 a
-H 16.0 14.0 -
& 12.0 E
,.I
- t I
=*'
10.0-8.0 rn Ji SSES UNIT 1 CYCLE 16
.4 m------
4 I
I I
4 4
I 4
1 I
4 4
I 4
4 i
I l
4 I
i I
I I
4 1
4 4
4 4
4 I
e 1
4 4
41e 4
I 4
o I
4 I
e I
4 4
4 4
4 I
I I
I 4 I 4 I in n
4o 1
lu
,C nI I
C oI I
u I
t I
I n
4 1
1 4
1i1 4
1 4
1 1
I 1
I
.i I
I Lu A
-I u
0...
.5
'O,;
5 USEDIN DETERMINING MAPRAT 4.
0 C
I l C I
I C
i iC I
4 i
4 l
I I
i C
4 I
C I
I I
I I
iI 67000,6.9 C
n 4
I C
I C
II C
o I
C I
I C
I I
I C
C u
C 4
4 4
I C,
I I
i I
I
- ~~~~~~~~~~~~~~
I o
Iotn I
C C I I
4 I
I C
4 I
C 4
I I
I i
I 4
C I
C u
4 C
I o
I I
o o
I I
I 4
I
~
4 s
C 1
1 I
I I
Cn CI 4u 4
- I C
I a
C I
I l
I I
I i
I
.4 I
l C
C I
I 4
I I
C C
CCII I
I n
- C
'-m-m m
c-o F N-j-C C
6.0 4.0 r-(D o <
CD I 0
6
--3 co U1 6
0 10000 20000 30000 40000 50000 Average Planar Exposure (MWD/MTU)
AVERAGE PLANAR LINEAR HEAT GENERATION RATE LIMIT VERSUS AVERAGE PLANAR EXPOSURE TWO LOOP OPERATION ATRIUMTm-10 FUEL
- FIGURE 4.2-1 60000 70000
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 9 of 53 5.0 MINIMUM CRITICAL POWER RATIO (MCPR) 5.1 Technical Specification Reference Technical Specification 3.2.2, 3.3.4.1, 3.7.6, and 3.7.8 5.2 Description The MCPR limit is specified as a function of core power, core flow, average scram insertion time per Section 5.3 and plant equipment operability status. The MCPR limits for all fuel types (ATRIUMTM-10) shall be the greater of the Flow-Dependent or the Power-Dependent MCPR, depending on the applicable equipment operability status.
a)
Main Turbine Bypass I EOC-RPT / Backup Pressure Regulator Operable Figure 5.2-1: Flow-Dependent MCPR value determined from BOC to EOC Figure 5.2-2: Power-Dependent MCPR value determined from BOC to EOC b)
Main Turbine Bypass Inoperable Figure 6.2-3: Flow-Dependent MCPR value determined from BOC to EOC Figure 5.2-4: Power-Dependent MCPR value determined from BOC to EOC c)
EOC-RPT Inoperable Figure 5.2-5: Flow-Dependent MCPR value determined from BOC to EOC Figure 5.2-6: Power-Dependent MCPR value determined from BOC to EOC d)
Backup Pressure Regulator Inoperable Figure 5.2-7: Flow-Dependent MCPR value determined from BOC to EOC Figure 5.2-8: Power Dependent MCPR value determined from BOC to EOC The MCPR limits in Figures 5.2-1 through 5.2-8 are valid for Two Loop operation.
The MCPR limits for Single Loop operation are provided in Section 8.0.
SUSQUEHANNA UNIT 1 TRM/3.2-10 EFFECTIVE DATE 03/17/2008
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 10 of 53 5.3 Average Scram Time Fraction If the average measured scram times are greater than the Realistic Scram times listed in Table 5.3-1 then the MCPR operating limits corresponding to the Maximum Allowable Average Scram Insertion Time must be implemented.
Determining MCPR operating limits based on interpolation between scram insertion times-is not permitted. The evaluation of scram insertion time data, as it relates to the attached table should be performed per Reactor Engineering procedures.
SUSQUEHANNA UNIT 1 TRM/3.2-11 EFFECTIVE DATE 03/17/2008
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 11 of 53 Main Turbine Bypass / EOC-RPT I Backup Pressure Regulator Operable SUSQUEHANNA UNIT 1 TRM/3.2-12 EFFECTIVE DATE 03/17/2008
Cr)
Cr) m
.1
-H I.
2.2 2.1 2.0 1.9
-H N)
I.
C~)
1.8 1.7 0
0-1.6 SSES UNIT I CYCLE 16 LEGEND CURVE A: MAXIMUM ALLOWABLE AVERAGE SCRAM INSERTION TIME CURVE B: REALISTIC AVERAGE SCRAM INSERTION TIME SAFETY ANALYSES ASSUME THAT FOUR BYPASS VALVES ARE OPERABLE PER SR 3.7.6.1 AND 3.7.6.2 USED IN DETERMINING MFLCPR (30,1.60)
ý( 3 )A (108,1.36)
REFERENCE:
T.S. 3.2.2
'1..
(83.4,1.34)
B (108.1.34) m m
CD) 00:
1.5 1.4 1.3 1.2
- u 16 00 0
0; 30 40 50 60 70 80 90 100 110 Total Core Flow (MLBIHR)
MCPR OPERATING LIMIT VERSUS TOTAL CORE FLOW MAIN TURBINE BYPASS / EOC-RPT / BACKUP PRESSURE REGULATOR OPERABLE TWO LOOP OPERATION (BOC TO EOC)
FIGURE 5.2-1
-D CA WJ
- u
m SSES UNIT 1 CYCLE 16 3.4 3.2 3.0 2.8 m
m c:)
0-
"17
-H7 m
1-I N)..
=~ 2.6 E
E 2.4 0 2.2 2.0 1.8 1.6 1.4 1.2 CD C-CD 20 30 40 50 60 70 80 so 100 Core Power (% RATED)
MCPR OPERATING LIMIT VERSUS CORE POWER MAIN TURBINE BYPASS I EOC-RPT I BACKUP PRESSURE REGULATOR OPERABLE TWO LOOP OPERATION (BOC TO EOC)
FIGURE 5.2-2
-u CD 03 0
03 CD C
-u,r-z-Il CO 0
C)O
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 14 of 53 Main Turbine Bypass Inoperable SUSQUEHANNA UNIT I TRM/3.2-15 EFFECTIVE DATE 03/17/2008
c/)
r-SSES UNIT I CYCLE 16 2.2 2.1 2.0 1.9 I
____I__.11 LEGEND CURVE A: MAXIMUM ALLOWABLE AVERAGE SCRAM INSERTION TIME CURVE B: REALISTIC AVERAGE SCRAM INSERTION TIME (30,1.95)
SAFETY ANALYSES ASSUME THAT TWO OR MORE BYPASS VALVES ARE INOPERABLE PER SR 3.7.6.1 OR 3.7.6.2
~1.8 0)
~1.6 USED IN DETERMINING MFLCPR K
m m
F--
m m
czH CA IQ 1.5 1.4 1.3 1.2
REFERENCE:
T.S. 3.7.6 and 3.2.
I _ _
5 (0
30 40 50 60 70 80 90 100 110 Total Core Flow (MLB/HR)
MCPR OPERATING LIMIT VERSUS TOTAL CORE FLOW MAIN TURBINE BYPASS INOPERABLE TWO LOOP OPERATION (BOC TO EOC)
FIGURE 5.2-3 CD 0M
- 0 z0 I-6I'5
m T-3.4 3.2 3.0 2.8 co) m~11
-n m
m
-H N:)
2.6 E
2.4 0 2.2 2.0 1.8 1.6 1.4 1.2 SSES UNIT I CYCLE 16 FLEGEND (23,3.19)
-CURVE A: MAXIMUM ALLOWABLE AVERAGE SCRAM INSERTION TIME (26,2.94)
CURVE B: REALISTIC AVERAGE SCRAM INSERTION TIME SAFETY ANALYSES ASSUME THAT TWO OR MORE BYPASS
_VALVES ARE INOPERABLE PER SR 3.7.6.1 OR 3.7.6.2
____USED IN DETERMINING MFLCPR (36,1.82)
A I3(94.46,1.44)_
]
REFERENCE:
T.S. 3.7.6 and 3.2.21
-u-u
(-
CD 20 30 40 50 60 Core Power (% RATED) 70 80 90 100 MCPR OPERATING LIMIT VERSUS CORE POWER MAIN TURBINE BYPASS INOPERABLE TWO LOOP OPERATION (BOC to EOC)
FIGURE 5.2-4 TD 0)
(0 (D~
CA 0
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 17 of 53 EOC-RPT Inoperable SUSQUEHANNA UNIT 1 TRM/3.2-18 EFFECTIVE DATE 03/17/2008
(AI SSES UNIT 1 CYCLE 16 2.2 2.1 2.0 4
4-4-
I I
II LEGEND CURVE A: MAXIMUM ALLOWABLE AVERAGE SCRAM INSERTION TIME CURVE B: REALISTIC AVERAGE SCRAM INSERTION TIME 1'
I-1.9 E 1.8 1.7 0.
0 1.6 1.5 SAFETY ANALYSES ASSUME THAT FOUR BYPASS VALVES ARE OPERABLE PER SR 3.7.6.1 AND 3.7.6.2 USED IN DETERMINING MFLCPR A
B
REFERENCE:
T.S. 3.3.4.1 and 3.2.2 (71.1,1.40)
(108,1.40)
I-(0 m
m m
m N) cx 1.4 1.3 1.2 30 40 50 60 70 80 90 100 110 Total Core Flow (MLB/HR)
MCPR OPERATING LIMIT VERSUS TOTAL CORE FLOW EOC-RPT INOPERABLE TWO LOOP OPERATION (BOC TO EOC)
FIGURE 5.2-5 0 CD F U3 00 6
01 0
C.0)
.- L
m
- 1 3.4 3.2 3.0 2.8 CD) m m
co mo g 2.6 E
2.4 d)
CLa.
o 2.2 0.
a.
S2.0 1.8 1.6 1.4 1.2 SSES UNIT 1 CYCLE 16 1
I I
I
.LEGEND 23,3.121 CURVE A: MAXIMUM ALLOWABLE AVERAGE SCRAM INSERTION TIME (26,2.94)
CURVE B: REALISTIC AVERAGE SCRAM INSERTION TIME SAFETY ANALYSES ASSUME THAT FOUR BYPASS VALVES ARE OPERABLE PER SR 3.7.6.1 AND 3.7.6.2 II "1
I 1
USED IN DETERMINING MFLCPR
~A
REFERENCE:
T.S. 3.3.4.1 and 3.2.21 (80,1.42)
(94.46,1.40)
-0 20 30 40 50 60 70 80 90 100 Core Power (% RATED)
MCPR OPERATING LIMIT VERSUS CORE POWER EOC-RPT INOPERABLE TWO LOOP OPERATION (BOC to EOC)
FIGURE 5.2-6 CD 0
0, CD 0
-v z
1"1 0
0 0
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 20 of 53 Backup Pressure Regulator Inoperable SUSQUEHANNA UNIT I TRM/3.2-:21 EFFECTIVE DATE 03/17/2008
- jcr, SSES UNIT 1 CYCLE 16 2.2 2.1 2.0 1.9 4
- 4.
4 IIII LEGEND CURVE A: MAXIMUM ALLOWABLE AVERAGE SCRAM INSERTION TIME CURVE B: REALISTIC AVERAGE SCRAM INSERTION TIME 4
- 4.
4
- 1 SAFETY ANALYSES ASSUME THAT FOUR BYPASS VALVES ARE OPERABLE PER SR 3.7.6.1 AND 3.7.6.2 r
-H CA)
N)
N)
N)
~1.8 S1.7 0.
0 1.6 m
m m1 m
c:)
CD)
'-S 1.5 1.4 1.3 1.2 USED IN DETERMINING MFLCPR (30,1.60)
REFERENCE:
T.S. 3.7.8 and 3.2.2 (79.3,1.36)
(108,1.36
"-u C-CD CD 30 40 50 60 70 80 90 100 110 Total Core Flow (MLB/HR)
MCPR OPERATING LIMIT VERSUS TOTAL CORE FLOW BACKUP PRESSURE REGULATOR INOPERABLE TWO LOOP OPERATION (BOC TO EOC)
FIGURE 5.2-7 CD 0
-CA W1 (D
C0
-vz 90 0
C/)
mC
-H 3.4 3.2 3.0 2.8 2.6 E
2.4 CL 0 2.2 L,) 2.0 1.8 1.6 1.4 1.2 SSES UNIT 1 CYCLE 16 II LEGEND (23,3.12)
CURVE A: MAXIMUM ALLOWABLE AVERAGE SCRAM INSERTION TIME (26,2.94)
CURVE B: REALISTIC AVERAGE SCRAM INSERTION TIME SAFETY ANALYSES ASSUME THAT FOUR BYPASS VALVES USED IN DETERMINING MFLCPR (3
.894
--.<A B.<
-FRFERNCE
- ..378ad32.1(44,.6 (8,. 5
-u Ct, CO 20 30 40 50 60 70 80 90 100 Core Power (% RATED)
MCPR OPERATING LIMIT VERSUS CORE POWER BACKUP PRESSURE REGULATOR INOPERABLE TWO LOOP OPERATION (BOC to EOC)
FIGURE 5.2-8 CD cn WD
.u CDI-z n6 co 0
50
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 23 of 53 Table 5.3-1 Average Scram Time Fraction Table For Use With Scram Time Dependent MCPR Operating Limits Control Rod Average Scram Time to Position (seconds)
Position 45 0.470 0.520 39 0.630 0.860 25 1.500 1.910 5
2.700 3.440 Average Scram Realistic Maximum Insertion Time Allowable
.SUSQUEHANNA UNIT 1 TRM/3.2-24 EFFECTIVE DATE 03/17/2008
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 24 of 53 6.0 LINEAR HEAT GENERATION RATE (LHGR) 6.1 Technical Specification Reference Technical Specification 3.2.3 and 3.7.6 6.2 Description The maximum LHGR for ATRIUMTM-10 fuel shall not exceed the LHGR limit determined from Figure 6.2-1. The LHGR limit in Figure 6.2-1 is valid for Main Turbine Bypass Operable and Inoperable, EOC-RPT Operable and Inoperable, and Backup Pressure Regulator Operable and Inoperable.
To protect against both fuel centerline melting and cladding strain during anticipated system transients initiated from reduced power and flow conditions, power and flow dependent LHGR limit multipliers are provided. The following figures are applicable to EOC-RPT Operable and Inoperable and Backup Pressure Regulator Operable and Inoperable:
a)
Main Turbine Bypass Operable Figure 6.2-2: Flow-Dependent LHGR Limit Multiplier Figure 6.2-3: Power-Dependent LHGR Limit Multiplier b)
Main Turbine Bypass Inoperable Figure 6.2-4: Flow-Dependent LHGR Limit Multiplier Figure 6.2-5: Power-Dependent LHGR Limit Multiplier The LGHR limit and LHGR limit multipliers in Figures 6.2-1 through 6.2-5 are valid for both Two Loop and Single Loop operation.
SUSQUEHANNA UNIT 1 TRM/3.2-25 EFFECTIVE DATE 03/17/2008
aSSES UNIT 1 CYCLE 16 1 6.0
'I II I
I III I
II I
I I
I I
I I
.,i l
l I.
I I
I I
II 1
1I i
i
,I I
I II II I
I I
I I
I a14.0
-.0 Z
0ii0,13.4 i:
0-*1
REFERENCE:
T.S. 3.2.3 i
.--- v USEIN DETERMINING FDLRX I
IISI I
Il 1
11CI 1...................
NA)
.2
- T CD-0 0 13
= =*
=:....
"~~.........
,1,
[
caD 6,0 CD C
E Pell l
l l
l lletE p
s r
(l l
Dl MTU
)
W (Dll l
l co C
i i
i i
i i
i i
i i
i i
i i
i iI I
II I
I I
I I
Il l
l, I
il l
l I
IIII*IIIIIIIIIIIIIIIIIIIIIIIIIIIII I
I 6.0R 62-1 1
1 11IIlI I
I l
l I
I I
liI I
I I
I I
I I
II I
I I
I I
I I
I I
Ia I
I5
.100
-I I
I I
I I
l l
l l
l l
l l
l l1 l
l l
1 1
I I P I
I I
I I
I I
I I
o I
I I
IIIII Il I
Ill l
l l
l l
l l
I I
Il l
i 4.0
+-l~l
-. ll.
l.....
.~ll l.................l.
dl l
llk llml 0
00 00 300 4000500 600 000800 Pele xpsre(WDMU)I I
I l
II I
IZ LIEAIHA GNEAIO RT LIMIT VESUPLETEXOUR I
iC ATR...IUM.
M...1.0..FUEL.
m I
=FIGURE 6.2-1
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 26 of 53 Main Turbine -Bypass Operable SUSQUEHANNA UNIT 1 TRM/3.2-27 EFFECTIVE DATE 03/17/2008
1.10 PT1 1.00 0.90 E-
- 0.80
-J N.)
co 0r 0.70 0.
0 0.60 4 SSES UNIT 1 CYCLE 16 I
I6 6
(75,1.00)
I A
T108,1.0SS MET ATFO R BY AS0AL E I
I I
I I
II IIIlI I
6 5
REFERENCE:
T.S. 3.2.3 and 3.7.
I I
I I
I I
I I
i I
IiI
- USED IN DETERMINING FDLRX i
I I
I I
I SrI 6
I i
S I
i i
I i
I I
6 I
i i
i e
I I
I I
I I
I I
i i
s P ~ I r*
i6fi i l l t l
l l
e I l
l 6
5 6
1 l
1 I
IIlI e
l l
t t e
t l
II I I I.
I e
. I I
I I
I i-I I
I I
I I
I I
Si...........
I I
I I
I I
I I
I I
I co r-CD m
-Ti
-TI"
-H 0.50-r'ri CA) 0.40
- 3 c=).
co*
0 40 50 60 70 80 90 100 110 Total Core Flow (MLB/hr)
(r
<0 I
(D Z
FLOW DEPENDENT LHGR LIMIT MULTIPLIER o -m MAIN TURBINE BYPASS OPERABLE 0
co UTM
- cn~
ATRIUM
-10 FUEL w
FIGURE 6.2-2
SSES UNIT I CYCLE 16 Q
1.10.
B".N.6
..4
- 4. 1 0).
1.00
.......i
.r 0
8 i
Ie REEENE T.S 3..
an 3..
- -T
-n 0.7 r
r ---
I "I
I..
AR OP R
B EP RSI...
N mn C-4 ir (26,0.49)i ii m
I I
I I
I I
I I
I I
I I
I-.
I I
I I
I I
I I
I i
IIII I
l I
I I
I I
lI,
,I I
i I
I I
I I
I I
I 0.40 20 30 40 50 60 70 80 90 100 CD Core Power (% RATED)
W CD ;
00
~CD
-Z POWER DEPENDENT LHGR LIMIT MULTIPLIER co MAIN TURBINE BYPASS OPERABLE 0
9 ATRIUMTM.10 FUEL FU62
- 1 i
l i
F IG R
6.ii2-3
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 29 of 53 Main Turbine Bypass Inoperable SUSOUEHANNA UNIT 1 TRM/3.2-30 EFFECTIVE DATE 03/17/2008
SSES UNIT 1 CYCLE 16 i i m
-r1 I--
N>
C) 00 I-
-J
.1-o 04.
r-r-1 I:
m CAo I.
N3 I-....- -
1.00 S(108,1.00)
SAFETY ANALYSES ASSUME THAT TWO OR MORE BYPASS VALVES ARE INOPERABLE PER SR 3.7.6.1 OR 3.7.6.2
REFERENCE:
T.S. 3.2.3 and 3.7.6 T..
- f..
L
."I 0.60............
I 4---..
USED IN DETERMINING FDLRX 94
.00....
0.0 I
I I
I i
- i.
I
- i.
s I
I I
I I
I
!I I
i I
/
I I
I i
o e
I o
I i
i a
I I
i I
i I
g I
i i
I II I
£ I
I I
I I
TI CO 30 40 50 60 70 80 90 100 110 Total Core Flow (MLBIHR) r--
CD Z
FLOW DEPENDENT LHGR LIMIT MULTIPLIER o
6 MAIN TURBINE BYPASS INOPERABLE M
0 ATRIUMTM1 0 FUEL 2
FIGURE 6.2-4
1SSES UNIT 1 CYCLE 16 1.00 NJ S
1 7
'(94.4.6,1.00) 0.7....................................
L.......
V A INO
.R BL P
SR 3...... O g.2(
C e 0. 0i i
i i
j J...
i CA
- (3630.71)
AFETY ANALSES ASSUME HAT TWO ORMORE BYPAS
REFERENCE:
T.S. 3.2.3 and 3.7.6..
0 CL S.
USED IN DETERMINING FDLRX m
m C=)
I I(26,O.49)
I I
I I
I I
I II II I
I I
I I
I I
I I
0.401 20 30 40 50 60 70 80 90 100 CDCore Power (% RATED)
)DT C)
I I
I i
iI lI lI II I
- k POWER DEPENDENT LHGR LIMIT MULTIPLIER c 1
- 3 MAIN TURBINE BYPASS INOPERABLE6 ATRIU
-0 FUELUMIlC FIGURE 6.2-5
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 32 of 53 7.0 ROD BLOCK MONITOR (RBM) SETPOINTS AND OPERABILITY REQUIREMENTS 7.1 Technical Specification Reference Technical Specification 3.3.2.1 7.2 Description The RBM Allowable Value and Trip Setpoints for; a)
Low Power Range Setpoint, b)
Intermediate Power Range Setpoint, c)
High Power Range Setpoint, e)
Low Power Range - Upscale, f)
Intermediate Power Range - Upscale, and g)
High Power Range - Upscale shall be established as specified in Table 7.2-1. The RBM setpoints are valid for Two Loop and Single Loop Operation, Main Turbine Bypass Operable and Inoperable, EOC-RPT Operable and Inoperable, and Backup Pressure Regulator Operable and Inoperable.
The RBM system design objective is to block erroneous control rod withdrawal initiated by the operator before fuel design limits are violated. If the full withdrawal of any control rod would not violate a fuel design limit, then the RBM system is not required to be operable. Table 7.2-2 provides RBM system operability requirements to ensure that fuel design limits are not violated.
SUSQUEHANNA UNIT 1 TRM/3.2-33 EFFECTIVE DATE 03/17/2008
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 33 of 53 Table 7.2-1 RBM Setpoints Function Allowable Nominal Trip Value(')
Setpoint Low Power Range Setpoint 28.0 24.9 Intermediate Power Range Setpoint 63.0 61.0 High Power Range Setpoint 83.0 81.0 Low Power Range - Upscale 123.4 123.0 Intermediate Power Range - Upscale 113.6 113.2 High Power Range - Upscale 110.6 110.2
(
Power setpoint function (Low, Intermediate, and High Power Range Setpoints) determined in percent of rated thermal power. Upscale trip setpoint function (Low, Intermediate, and High Power Range - Upscale) determined in percent of reference level.
Table 7.2-2 RBM System Operability Requirements Thermal Power MCPR (2,3)
(% of Rated)
- 2t 28 and < 90
< 1.76
-90 and < 95
< 1.47 (2)
Applicable to Main Turbine Bypass Operable and Inoperable, EOC-RPT Operable and Inoperable, and Backup Pressure Regulator Operable and Inoperable.
()
Applicable to both Two Loop andSingle Loop Operation.
SUSQUEHANNA UNIT I TRM/3.2-34 EFFECTIVE DATE 03/17/2008
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 34 of 53 8.0 RECIRCULATION LOOPS - SINGLE LOOP OPERATION 8.1 Technical Specification Reference Technical Specification 3.2.1, 3.2.2, 3.2.3, 3.3.4.1, 3.4.1, 3.7.6, and 3.7.8 8.2 Description APLHGR The APLHGR limit for ATRIUMTM-1 0 fuel shall be equal to the APLHGR Limit from Figure 8.2-1.
The APLHGR limits in Figure 8.2-1 are valid for Main Turbine Bypass Operable and Inoperable, EOC-RPT Operable and Inoperable, and Backup Pressure Regulator Operable and Inoperable in Single Loop operation.
Minimum Critical Power Ratio Limit The MCPR limit is specified as a function of core power, core flow, and plant equipment operability status. The MCPR limits for all fuel types (ATRIUMTM-10) shall be the greater of the Flow-Dependent or the Power-Dependent MCPR, depending on the applicable equipment operability status.
a)
Main Turbine Bypass / EOC-RPT / Backup Pressure Regulator Operable Figure 8.2-2: Flow-Dependent MCPR value determined from BOC to EOC Figure 8.2-3: Power-Dependent MCPR value determined from BOC to EOC b)
Main Turbine Bypass Inoperable Figure 8.2-4: Flow-Dependent MCPR value determined from BOC to EOC Figure 8.2-5: Power-Dependent MCPR value determined from BOC to EOC c)
EOC-RPT Inoperable Figure 8.2-6: Flow-Dependent MCPR value determined from BOC to EOC Figure 8.2-7: Power-Dependent MCPR value determined from BOC to EOC d)
Backup Pressure Regulator Inoperable Figure 8.2-8: Flow-Dependent MOPR value determined from BOO to EOO Figure 8.2-9: Power-Dependent MCPR value determined from BOC to EOC SUSQUEHANNA UNIT I TRH/3.2-35 EFFECTIVE DATE 03/17/2008
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 35 of 53 The MCPR limits in Figures 8.2-2 through 8.2-9 are valid only for Single Loop operation.
Linear Heat Generation Rate Limit The LHGR limits for Single Loop Operation are defined in Section 6.0.
RBM Setpoints and Operability Requirements The RBM setpoints and operability requirements for Single Loop Operation are defined in Section 7.0.
SUSQUEHANNA UNIT I TRM/3.2-36 EFFECTIVE DATE 03/11/2008
C--
.CD r-H ri-.
16.0 14.0 12.0.
.E
-j
,..1
- oc N)
.20~
0
- 1O.0 8.0 8.0_
0-n SSES UNIT 1 CYCLE 16 m
a
- r.
+.
I.
i a
I a
I a
n REFERENCE T.S.3.4.1 and 3.2.1 u
- a.
e o
USED IN DETERMINING MAPRAT S...............
a a
I a
InS S
a a
,n a
,.n I
I a
I.
.a
.a..a..
i I
a I
a 0.0,10.015000,10.0-:S I
S I
5 I
i I
a l
a I
a
- i i.2 t.l.....
- l.
a i
a a
a al a
a a
a a s a
a a
I S
5 5
1 a
a I
a s
0.0,100.0::15000,10.0:
a i
o i
o l
1 1
i 1
1 I a
I e
i a a
I a
a 5
5 5
5 I
i a
67000,5.6 l
S Ia a
I aI I
I al I
I I
l U
I I...
l
- a.
a a
i a
a
.aI II I
a a
.I S I I
5 I
S a
s I
I I
S I
I I I
I l
ll a
l sO I
s l
I I
I I
I I
a i
a a
a sI aI I I
a a
l I
l l
i i
i i
.i i
i
=
i l
C-(0
'-r1 m
rni N) :
m I-+-
ra-N) 6.0 4.0 0
10000 20000 30000 40000 50000 Average Planar Exposure (MWDIMTU)
AVERAGE PLANAR LINEAR HEAT GENERATION RATE LIMIT VERSUS AVERAGE PLANAR EXPOSURE SINGLE LOOP OPERATION ATRIUMTM-10 FUEL FIGURE 8.2-1 60000 70000 W
cD r-CD "
C) -n 01 C)
C)
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 37 of 53 Main Turbine Bypass / EOC-RPT I Backup Pressure Regulator Operable SUSQUEHANNA UNIT I TRM/3.2-38 EFFECTIVE DATE 03/17/2008
L/)
ni
- 1 SSES UNIT I CYCLE 16 2.2 LEGEND CURVE A: MAXIMUM ALLOWABLE AVERAGE SCRAM INSERTION TIME CURVE B: REALISTIC AVERAGE SCRAM INSERTION TIME 2.1 t
1--
(30,2.02)
C.,
N)
CA) 2.0 E
.-1 1.9 0.
0ý u
1.8 SAFETY ANALYSES ASSUME THAT FOUR BYPASS VALVES ARE OPERABLE PER SR 3.7.6.1 AND 3.7.6.2 1I 1
t
~
I USED IN DETERMINING MFLCPR (D
t 4
+
4 4
m
-n C-)
m m
CA) c)
A B
i 1.7 t
4 4-(79.3,1. "7*1\\
.LI 4
- nI I
=
I
REFERENCE:
T.S. 3.4.1 and 3.2.21 (108,1.72) 1.6 300 40 50 60 70 80 90 100 110 Total Core Flow (MLB/HR)
MCPR OPERATING LIMIT VERSUS TOTAL CORE FLOW MAIN TURBINE BYPASS I EOC-RPT / BACKUP PRESSURE REGULATOR OPERABLE SINGLE LOOP OPERATION (BOC to EOC)
FIGURE 8.2-2 T ;u c~<
CD *
.0 C
-4, to
-D,I-z-n 6
Co 6
ILA Lf) 7-1 ->
I.
SSES UNIT I CYCLE 16 4.1 3.9 3.7 3.5
-o 3.3
--3.1 0,,
d-2.9 o.
0 cL2.7 2.5
-0 CD
-n
-P cP C)
P1m N) 2.3 2.1 1.9 1.7 20 30 40 50 60 70 80 90 100 Core Power (% RATED)
MCPR OPERATING LIMIT VERSUS CORE POWER MAIN TURBINE BYPASS I EOC-RPT / BACKUP PRESSURE REGULATOR OPERABLE SINGLE LOOP OPERATION (BOC to EOC)
FIGURE 8.2-3
-u (D
CO CO (0
2, CD 0
-u,I-z-nl 6
C)--x
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 40 of 53 Main Turbine Bypass Inoperable SUSQUEHANNA UNIT 1 TRM/3.2-41 EFFECTIVE DATE 03/17/2008
N, SSES UNIT I CYCLE 16 2.6 2.5 2.4 E2.3
.E 2.2 0.
0.
S2.1 I
I I
I (30,2.46)
Io EGEND URVE A: MAXIMUM ALLOWABLE AVERAGE SCRAM INSERTION TIME URVE B: REALISTIC AVERAGE SCRAM INSERTION TIME
.AFETY ANALYSES ASSUME THAT TWO OR MORE BYPASS VALVES ARE INOPERABLE PER SR 3.7.6.1 OR 3.7.6.2
'4ýý I
I USED IN DETERMINING MFLCPR t
1~
1~ ~~-I
-u (D
rn mD CD m0 2.0 1.9
REFERENCE:
T.S. 3.4.1, 3.7.6, and 3.2.2 1.8 30 40 50 60 70 80 90 100 110 Total Core Flow (MLBIHR)
MCPR OPERATING LIMIT VERSUS TOTAL CORE FLOW MAIN TURBINE BYPASS INOPERABLE SINGLE LOOP OPERATION (BOC to EOC)
FIGURE 8.2-4 0
-- h cn
- 0~
CD0; 0
L71 4.1 3.9 3.7 3.5
-H C~~)
3.3 E
n 3.1 2.9 CL a)a.
0 CL 2.7 2.5 SSES UNIT I CYCLE 16
(
3I I
I I
CURVE A: MAXIMUM ALLOWABLE AVERAGE SCRAM
( 6 INSERTION TIME CURVE B: REALISTIC AVERAGE SCRAM INSERTION TIME SAFETY ANALYSES ASSUME THAT TWO OR MORE BYPASS VALVES ARE INOPERABLE PER SR 3.7.6.1 OR 3.7.6.2 USED IN DETERMINING MFLCPR (36,2.29)
(60,2.06)
(94.46,2.06)-
-T
REFERENCE:
T.S. 3.4.1, 3.7.6, and 3.2.21
-U
-u I-CD Co CD c::
co 2.3 2.1 1.9 1.7 20 30 40 50 60 70 80 90 100 Core Power (% RATED)
MCPR OPERATING LIMIT VERSUS CORE POWER MAIN TURBINE BYPASS INOPERABLE SINGLE LOOP OPERATION (BOC to EOC)
FIGURE 8.2-5 CDi co
- 0 I-3 z-n 90 0,
0 0r
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 43 of 53 EOC-RPT Inoperable SUSQUEHANNA UNIT 1 TRM/3.2-44 EFFECTIVE DATE 03/17/2008
m 2.2 2.1 2.0 E
0-1.9 0
C, 1.8 SSES UNIT I CYCLE 16 LEGEND CURVE A: MAXIMUM ALLOWABLE AVERAGE SCRAM INSERTION TIME CURVE B: REALISTIC AVERAGE SCRAM INSERTION TIME (30,2.02)
SAFETY ANALYSES ASSUME THAT FOUR BYPASS VALVES ARE OPERABLE PER SR 3.7.6.1 AND 3.7.6.2 USED IN DETERMINING MFLCPR B
A (71.1,1.77)
(108,1.77)
REFERENCE:
T.S. 3.4.1, 3.3.4.1, and 3.2.2 m
-n m
CD)
C=)
00 1.7 C.0 (0
CI 1.6 30 40 50 60 70 80 90 100 110 Total Core Flow (MLB/HR)
MCPR OPERATING LIMIT VERSUS TOTAL CORE FLOW EOC-RPT INOPERABLE SINGLE LOOP OPERATION (BOC to EOC)
FIGURE 8.2-6
-a (0
(D ;0 (D
C SSES UNIT I CYCLE 16
(/)
Cl m 4.1 3.9 3.7 3.5 3.3 E
-J 3.1 CD 4-2.9 0.
.2.7 2.5
-U I--
<D CO
--t m-n C-)
CA) c:)
2.3 2.1 1.9 1.7 20 30 40 50 60 70 80 Core Power (% RATED)
MCPR OPERATING LIMIT VERSUS CORE POWER EOC-RPT INOPERABLE SINGLE LOOP OPERATION (BOC to EOC)
FIGURE 8.2-7 90 100
--h CA 01 01 CA)
- 0 -u z
Co 6I
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 46 of 53 Backup Pressure Regulator Inoperable SUSQUEHANNA UNITJ TRM/3.2-47 EFFECTIVE DATE 03/17/2008
S m
SSES UNIT I CYCLE 16 2.2 LEGEND CURVE A: MAXIMUM ALLOWABLE AVERAGE SCRAM INSERTION TIME CURVE B: REALISTIC AVERAGE SCRAM INSERTION TIME 2.1 (30,2.02) 00 2.0 E
- a 1.9 0
1.8 1.8 SAFETY ANALYSES ASSUME THAT FOUR BYPASS VALVES ARE OPERABLE PER SR 3.7.6.1 AND 3.7.6.2 USED IN DETERMINING MFLCPR m
m m
c:j)
NH CD) co (108,1.72).
(79.3,1.72)
F
REFERENCE:
T.S. 3.4.1, 3.7.8, and 3.2.2I II (0
1.7 1.6 30 40 50 60 70 80 90 100 110
- Total Core Flow (MLB/HR)
MCPR OPERATING LIMIT VERSUS TOTAL CORE FLOW BACKUP PRESSURE REGULATOR INOPERABLE SINGLE LOOP OPERATION (BOC to EOC)
FIGURE 8.2-8 CD
-P i 0
h3 cA)
CD z 0
0"-
(A (A
m I'
-H 4.1 3.9 3.7 3.5 3.3 E
.-J3.1 0,,
4-
- 2.9 0
CL 2.7 2.5
-H N,
SSES UNIT 1 CYCLE 16 I
I..
(23,3.91)
LEGEND
_-CURVE A: MAXIMUM ALLOWABLE AVERAGE SCRAM (26,3.68)
INSERTION TIME CURVE B: REALISTIC AVERAGE SCRAM INSERTION TIME SAFETY ANALYSES ASSUME THAT FOUR BYPASS VALVES
.ARE OPERABLE PER SR 3.7.6.1 AND 3.7.6.2
__USED IN DETERMINING MFLCPR
_,,.__(94.46,2.25)_
(60,2.25)
REFERENCE:
T.S. 3.4.1, 3.7.8, and 3.2.2I 0
(0 m
CD)
NJ 2.3 2.1 1.9 1.7 20 30 40 50 60 70 80 90 100 Core Power (% RATED)
MCPR OPERATING LIMIT VERSUS CORE POWER BACKUP PRESSURE REGULATOR INOPERABLE SINGLE LOOP OPERATION (BOC to EOC)
FIGURE 8.2-9 CT ;
(a0<
(D co 0
r'-
z"I, 0co C0 0-.
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 49 of 53 9.0 POWER / FLOW MAP 9.1 Technical Specification Reference Technical Specification 3.3.1.1 9.2 Description Monitor reactor conditions to maintain THERMAL POWER / core flow outside of Stability Regions I and II of the Power / Flow map, Figure 9.1.
If the OPRM Instrumentation is OPERABLE per TS 3.3.1.1, Region I of the Power / Flow map is considered an immediate exi! region.
If the OPRM Instrumentation is inoperable per TS 3.3.1.1, Region I of the Power
/ Flow map is considered an immediate scram region.
Region II of the Power / Flow map is considered an immediate exit region regardless of the operability of the OPRM Instrumentation.
SUSQUEHANNA UNIT 1 TRM/3.2-50 EFFECTIVE DATE 03/17/2008
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 50 of 53 120 120
Purpose:
UNIT 1
-*-r " -- *
Trip Setpolnt 110 STABILITYR-ION!
R R.A RMRd l
IF OPRM INOPERABLE IMEDIATE L-T el I
R loo SCFLAM IAW ON-178-002 a
IF OPRM OPERABLE IMMEDIATE 100 EXg r[AW ON-17"-002 rTI-MELLLA T
Boundary-.
STABILITY RE-GION It
- f.
T 1---
r 73MWt IMMEDIATELY EXIT lAW ON.178-90 REGION Bou__ary.
9 (AS deflnod In Attachment G to L
NDAP-QA-033}
IF ABOVE MELLLA BOUNDARY.
L0 IMMEDIATELY EXIT lAW ON-178-002
"-- Rod Line 80 1
i i
i
__I I t
I I I
/
J I
w
-- F 0-L L.
4
.2 i.i i
I I
i I i
[
RodLine di
-l rT T7 ri
-T-1
"-1 -1
'-~~~
-l
'r-I r' 7'-*- -1 L~~~~~1
-I
.L L
-1 L
1_j jL 60 i....
J,
-j LJ-L J;-_.--
L-
- L * -
,.... IJ...
~ ~
i L
J.j
.L L J...4 40 Natra Circulatio
_____'___50 i
I IRESTICT i
REGIO 30
-L-iJ 50 50.0 0010 1
2 30-l 40r
-60 70-n 80-r 0-100 110 (f
f S-%u Se sF GO-i 0 0-00T6 4Sh Unit 1 Cyl 1P erma
- Hower, ap0 USUHN I
1 E
TI D
7 30 1
Apopx W
aESRCE REIO0 TWOnePurnp If >ý3ý an 6%
30% Speed, thra poer co pl with 7
J-CO32.
M 20 2
neu 0
T:*
17 1...
1 T
-'-1 t
1 10 10 2
0 4
0
- 0 7
0 9
0 10
.Total Core Flow (Mlbn/hr)
(for SLO <75% Pump Speedl Use Form GO-100-009-2)
Figure 9.1 SSES Unit I Cycle 16 Power/ Flow Map SUSQUEHANNA UNIT 1 TRM/3.2-51 EFFECTIVE DATE 03/17/2008
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 51 of 53 10.0 OPRM SETPOINTS 10.1 Technical Specification Reference Technical Specification 3.3.1.1 10.2 Description Setpoints for the OPRM Instrumentation are established that will reliably detect and suppress anticipated stability related power oscillations while providing a high degree of confidence that the MCPR Safety limit is not violated. The setpoints are described in Section 2.0 and are listed below:
Sp
=
1.11 Np
=
15 Fp
=
60 Mlbm / hr SUSQUEHANNA UNIT I TRM/3.2-52 EFFECTIVE DATE 03/17/2008
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 52 of 53
11.0 REFERENCES
11.1 The analytical methods used to determine the core operating limits shall be those previously reviewed and approved by the NRC, specifically those described in the following documents:
- 1. XN-NF-81-58(P)(A), Revision 2 and Supplements 1 and 2, "RODEX2 Fuel Rod Thermal-Mechanical Response Evaluation Model," Exxon Nuclear Company, March 1984.
- 2. EMF-2361 (P)(A), Revision 0, "EXEM BWR-2000 ECCS Evaluation Model,"
Framatome ANP, May 2001.
- 3. EMF-2292(P)(A), Revision 0, "ATRIUMTM-10: Appendix K Spray Heat Transfer Coefficients," Siemens Power Corporation, September 2000.
- 4. XN-NF-84-105"(P)(A), Volume 1 and Volume 1 Supplements 1 and 2, "XCOBRA-T: A Computer Code for BWR Transient Thermal-Hydraulic Core Analysis," Exxon Nuclear Company, February 1987.
- 5. XN-NF-80-19(P)(A), Volume 1 and Supplements 1 and 2, "Exxon Nuclear Methodology for Boiling Water Reactors: Neutronic Methods for Design and Analysis," Exxon Nuclear Company, March 1983.
- 6. XN-NF-80-19(P)(A), Volumes 2, 2A, 2B, and 2C "Exxon Nuclear Methodology for Boiling Water Reactors: EXEM BWR ECCS Evaluation Model," Exxon Nuclear Company, September 1982.
- 7. XN-NF-80-19(P)(A), Volume 3 Revision 2 "Exxon Nuclear Methodology for Boiling Water Reactors Thermex: Thermal Limits Methodology Summary Description," Exxon Nuclear Company, January 1987.
- 8. XN-NF-80-19(P)(A), Volume 4, Revision 1, "Exxon Nuclear Methodology for Boiling Water Reactors: Application of the ENC Methodology to BWR Reloads," Exxon Nuclear Company, June 1986.
- 9. XN-NF-85-67(P)(A), Revision 1, "Generic Mechanical Design for Exxon Nuclear Jet Pump BWR Reload Fuel," Exxon Nuclear Company, Inc.,
September 1986.
- 10. ANF-524(P)(A), Revision 2 and Supplements 1 and 2, "Advanced Nuclear Fuels Corporation Critical Power Methodology for Boiling Water Reactors,"
November 1990.
- 11. NE-092-001A, Revision 1, "Licensing Topical Report for Power Uprate With Increased Core Flow," Pennsylvania Power & Light Company, December 1992 and NRC SER (November 30, 1993).
SUSQUEHANNA UNIT I TRM/3.2-53 EFFECTIVE DATE 03/17/2008
PPL Rev. 9 PL-NF-08-001 Rev. 0 Page 53 of 53
- 12. ANF-89-98(P)(A) Revision 1 and Supplement 1, nGeneric Mechanical Design Criteria for BWR Fuel Designs," Advanced Nuclear Fuels Corporation, May 1995.
- 13. EMF-2209(P)(A), Revision 2, "SPCB Critical Power Correlation," Framatome ANP, September 2003.
- 14. EMF-85-74(P)(A), Revision 0, Supplement I (P)(A) and Supplement 2(P)(A),
"RODEX2A (BWR) Fuel Rod Thermal-Mechanical Evaluation Model,"
Siemens Power Corporation, February 1998.
- 15. EMF-2158(P)(A), Revision 0, "Siemens Power Corporation Methodology for Boiling Water Reactors: Evaluation and Validation of CASMO-4/Microburn-B2," Siemens Power Corporation, October 1999.
- 16. EMF-CC-074(P)(A), Volume 4, Revision 0, "BWR Stability Analysis -
Assessment of STAIF with Input from MICROBURN-B2," Siemens Power Corporation, August 2000.
- 17. NEDO-32465-A, "BWROG Reactor Core Stability Detect and Suppress Solutions Licensing Basis Methodology for Reload Applications," August 1996.
- 18. ANF-913(P)(A), Volume 1 Revision 1 and Volume 1 Supplements 2, 3, and 4, "COTRANSA2: A Computer Program for Boiling Water Reactor Transient Analyses," Advanced Nuclear Fuels Corporation, August 1990.
- 19. ANF-1358(P)(A), Revision 3, "The Loss of Feedwater Heating Transient in Boiling Water Reactors," Framatome ANP, September 2005.
SUSQUEHANNA UNIT I TRM/3.2-54 EFFECTIVE DATE 03/17/2008
OPRM Instrumentation 3.3.9 PPL Rev. 3 3.3 Instrumentation 3.3.9 OPRM Instrumentation Configuration TRO 3.3.9 Oscillation Power Range Monitor (OPRM) supporting setpoints and settings shall be within the specified limits.
APPLICABILITY:
Thermal POWER >23% RTP ACTIONS NOTE-------
- 1.
Separate Condition entry is allowed for each channel CONDITION REQUIRED ACTION COMPLETION TIME A.
OPRM Setpoints and A.1 Enter the condition referenced in Immediately Settings not in accordance Table 3.3.9-1 for the parameter with Table 3.3.9-1 B.
As required by Required B.1 Declare affected OPRM channel Immediately Action A.1 and referenced inoperable.
in Table 3.3.9.1 C.
As required by Required C.1 Restore the OPRM Setpoints and 120 days Action A.1 and referenced Settings to within the specified in Table 3.3.9-1 limits.
OR C.2 Declare affected OPRM channel Immediately inoperable D.
Alternate method to detect D.1 Initiate monitoring to detect entry Immediately and suppress thermal into Conditions E,F, and/or G.
hydraulic instability oscillations required by LCO 3.3.1.1 Required Action 1.1.
(continued)
SUSQUEHANNA - UNIT 1 TRM / 3.3-22 EFFECTIVE DATE 03/27/2008
OPRM Instrumentation 3.3.9 PPL Rev. 3 ACTIONS (continued)
CONDITION REQUIRED ACTION COMPLETION TIME E.
--- NOTE-----
Only applicable as required by Required Action D.1 E.1 Place reactor mode switch in the Immediately
-Total core flow as a shutdown position.
function of THERMAL POWER within Region I of the Power Flow map as specified in the COLR.
OR Total core flow as a function of THERMAL POWER within Region II of the Power Flow map as specified in the COLR and less than 50% of required LPRM upscale alarms OPERABLE F. -
NOTE-----
Only applicable as required by Required Action D.1 and when in Region II of the Power Flow map as specified in the COLR.
F.1 Place the reactor mode switch in Immediately Two or more APRM readings oscillating with the shutdown position.
one or more oscillating
Ž10% of RTP peak-to-peak OR (continued)
SUSQUEHANNA - UNIT 1 TRM / 3.3-22a EFFECTIVE DATE 11/15/2004
\\
OPRM Instrumentation PPL Rev. 3 3.3.9 CONDITION REQUIRED ACTION COMPLETION TIME F. (continued)
Two or more LPRM upscale alarms activating and deactivating with a period >1 second and *5 seconds.
OR Sustained LPRM oscillations >10 W/cm 2 peak-to-peak with a period
Ž>1 second and *5 seconds.
G. - -------- NOTE ----------
Only applicable as required by Required Action D.1.
Total core flow as a G.1 Initiate action to restore total core Immediately function of THERMAL flow as a function of THERMAL POWER is within Region II POWER outside of Region II.
of the Power Flow map as specified in the COLR.
H. Less than 50% of the H.1 Post sign on the reactor control 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> required LPRM Upscale panel that less than 50% of the Alarms are OPERABLE LPRM Upscale Alarms are I
SUSQUEHANNA - UNIT 1 TRM / 3.3-22b EFFECTIVE DATE 03/22/2006
PPL Rev. 3 OPRM Instrumentation 3.3.9 TECHNICAL REQUIREMENT SURVEILLANCE SURVEILLANCE FREQUENCY
+/-
TRS 3.3.9.1
NO TE ----------------------------
Only required to be met when an alternate method to detect and. suppress thermal hydraulic instability oscillations is required by LCO 3.3.1.1 Required Action 1.1.
Verify total core flow as a function of THERMAL POWER is outside of Region I and II of the Power Flow map as specified in the COLR.
24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> TRS 3.3.9.2 Perform CHANNEL CALIBRATION on the LPRM 24 months Upscale alarm 24 months TRS 3.3.9.3 Verify OPRM parameter setpoints and settings are within limits SUSQUEHANNA - UNIT 1 TRM / 3.3-22c EFFECTIVE DATE 03/22/2006
OPRM Instrumentation 3.3.9 PPL Rev. 3 Table 3.3.9-1 OPRM SETPOINTS AND SETTINGS CONDITIONS REFERENCED FROM OPRM REQUIRED PARAMETER DESCRIPTION ACTION A.1 VALUE
- 1.
TOL (-)
Period Tolerance B
>0.10 and
<_0.30 sec
- 2.
fc Conditioning Filter Cutoff Frequency B
1.5 Hz
- 3.
Tmin Oscillation Period Lower Time Limit B
>1.0 and -<.2 sec
- 4.
Tmax Oscillation Period Upper Time Limit B
3.5 sec
- 5.
LPRMmin Minimum LRPMs/Cell Required for Cell B
_2 Operability
- 6.
S1 Peak Threshold Setpoint/ABA & GRBA C
21.10 and
<1.20
- 7.
S2 Valley Threshold Setpoint/ABA & GRBA C
>0.85 and
,50.95
- 8.
Smax Amplitude Trip Setpoint/ABA C
>1.30 and
-51.50
- 9.
DR3 Growth Rate Factor Setpoint/GRBA C
>1.30 and
-<1.60 SUSQUEHANNA - UNIT 1 TRM / 3.3-22d EFFECTIVE DATE 03/22/2006
Reactor Recirculation Flow and Rod Line Limit 3.4.4 PPL Rev. 2 3.4 Reactor Coolant System (RCS) 3.4.4 Reactor Recirculation Flow and Rod Line Limit TRO 3.4.4 Operating loop flow rate shall be < 50% of rated loop flow rate and the reactor shall be operating at a THERMAL POWER/core flow condition below the 70%
rod line shown in the Power Flow map specified in the COLR.
APPLICABILITY:
MODES 1, 2, 3, and 4 during recirculation pump start.
ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A
Requirements of the A. 1 Restore parameter(s) to Prior to recirculation TRO not met within limits pump start TECHNICAL REQUIREMENT SURVEILLANCE SURVEILLANCE FREQUENCY TRS 3.4.4.1 Verify the operating loop flow rate is Once within 15 minutes prior
<50% of rated loop flow rate and that the to each recirculation pump reactor is operating at a THERMAL start POWER/core flow condition below the 70%
rod line shown in the power flow map specified in the COLR.
SUSQUEHANNA UNIT 1 TRM / 3.4-12 EFFECTIVE DATE 03/27/2008
Leading Edge Flow Meter (LEFM) 3.10.4 PPL Rev. 2 3.10.4 Section not used THIS PAGE INTENTIONALLY LEFT BLANK SUSQUEHANNA - UNIT 1 TRM / 3.10-8 EFFECTIVE DATE 03/27/2008
Heavy Loads Requirements 3.12.2 PPL Rev. 4 3.12 Loads Control Program 3.12.2 Heavy Loads Requirements TRO 3.12.2 The Technical Specification Limiting Conditions of Operation and Technical Requirements for Operation listed in Table 3.12.2-1 shall be met.
APPLICABILITY:
During movement of heavy loads in the proximity of irradiated fuel.
ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.
The Conditions of A.1 Suspend movement of heavy Immediately TRO 3.12.2 are not met.
loads in the proximity of irradiated fuel.
TECHNICAL REQUIREMENT SURVEILLANCE SURVEILLANCE FREQUENCY TRS 3.12.2.1 Administratively verify that all requirements of Within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> prior to TRO are met.
commencing movement of heavy loads AND Every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> thereafter SUSQUEHANNA - UNIT 1 TRM / 3.12-3 EFFECTIVE DATE 02/05/1999
Heavy Loads Requirements PPL Rev. 4 3.12.2 TABLE 3.12.2-1 TRO 3.12.2 REQUIREMENTS
- a.
LCO 3.3.6.2(a)
- b.
LCO 3.3.7.1(b)
- c.
LCO 3.6.4.1(c)
- d.
LCO 3.6.4.2(c)
- e.
LCO 3.6.4.3(d)
- f.
LCO 3.7.3(d)
- g.
LCO 3.7.7(e)
- h.
LCO 3.8.2(')
- i.
- j.
LCO 3.8.8(')
- k.
LCO 3.9.6 (g)
I.
TRO 3.3.4(
- m.
TRO 3.7.1(h)
- n.
TRO 3.9.1(g' (a) One trip system with all associated channels OPERABLE (Functions 3, 4, 5, 6 and 8).
Note that the available trip system must support the Table 3.12.2-le required SGT subsystem.
(b)
One trip system with all associated channels OPERABLE (Functions 3, 4, 5, 6, 8 and 9).
Note that the available trip system must support the Table 3.12.2-1f required CREOAS subsystem.
(c) Zone III only.
(d) Minimum of one subsystem OPERABLE.
(e) Only required for movement of heavy load in the proximity of irradiated fuel in the spent fuel storage pool.
c Minimum of one Table 3.3.4-1 Function 4 channel OPERABLE.
(9) Only required for movement of heavy load in the proximity of irradiated fuel in the' Reactor Pressure Vessel with the Steam Separator removed.
(h) Two ESW pumps capable of supplying cooling to the required diesel generators.
(i) Necessary AC Sources and Distribution Systems OPERABLE to support equipment required to be OPERABLE by TRM Table 3.12.2-1.
SUSQUEHANNA - UNIT 1 TRM / 3.12-4 EFFECTIVE DATE 03/14/2008
OPRM Instrumentation PPL Rev. 3 B 3.3.9 B 3.3.9 OPRM Instrumentation BASES TRO The OPRM system configuration governs its operation in accordance with the licensing analysis. Several configuration parameters are intrinsic to the trip function safety setpoint bases or provide settings for defense-in-depth algorithm features that are not assumed in the basis for the protection system safety analysis (Reference 2, Reference 3).
Each of the setting values may be used as the process setpoint or device setting without further adjustment for uncertainties.
Setpoints and Settings Bases TOL(-)
Period Tolerance The specified range of values for the period tolerance has been demonstrated to provide continuous confirmations upon transition from stable reactor operation to a growing reactor instability. A range of values is provided to allow system tuning to avoid spurious alarms on period confirmations. Limiting the setpoint adjustment range provides assurance that the Period Based Detection Algorithm will provide sufficient confirmations for a growing instability.
Conditioning Filter Cutoff Frequency The specified value for the Conditioning Filter Cutoff Frequency has been demonstrated to provide continuous confirmations upon transition from stable reactor operation to a growing reactor instability. Setting minimizes impact on signal amplitude and provides assurance that the Period Based Detection Algorithm will provide sufficient confirmations for a growing instability.
Tmin Oscillation Period, Lower Time Limit Tmax Oscillation Period Upper Time Limit The Oscillation Period Time Limit parameters establish the range of detectable oscillation periods of OPRM cell signals for signal oscillations associated with reactor core thermal-hydraulic instability.
(continued)
SUSQUEHANNA - UNIT 1 TRM / B 3.3-17 EFFECTIVE DATE 03/22/2006
OPRM Instrumentation B 3.3.9 PPL Rev. 3 B 3.3.9 OPRM Instrumentation BASES TRO (continued)
LPRMmin This value determines the availability and resulting sensitivity of cells in the reactor core in the event of LPRM channel failures. The minimum LPRM per cell parameter is an assumption of the OPRM trip setpoint (Sp) basis calculation.
Amplitude and Growth Rate Based Algorithm Parameters S1 S2 Smax Peak Threshold Setpoint / ABA + GRBA Valley Threshold Setooint / ABA + GRBA Amplitude Trip Setpoint / ABA DR3 Growth Rate Factor Setpoint / GRBA These parameters calibrate the Amplitude and Growth Rate Based Algorithm, described in References 2 and 3, which provides an OPRM trip output to the Reactor Protection System. The OPRM design and licensing basis takes no credit for the Amplitude and Growth Rate Based Algorithm. The algorithm is provided as a defense-in-depth feature in the event of unanticipated power oscillations. These Amplitude and Growth Rate Based Algorithm Parameters are considered sufficient to provide backup protection and to avoid spurious trips by maximizing margin to expected operating conditions and transients.
ACTIONS The required actions assure that the system settings that support the Period Based Algorithm setpoint analysis, and those parameters that define the Amplitude and Growth Rate Based Algorithm are returned in a timely manner to the values assumed in the analysis (Reference 2, Reference 3) or that the affected channel is declared inoperable and the applicable Required Action of LCO 3.3.1.1 is then entered, or an alternate method to detect and suppress thermal hydraulic instability oscillations is employed.
(continued)
SUSQUEHANNA - UNIT 1 TRM / B 3.3-17a EFFECTIVE DATE 03/22/2006
OPRM Instrumentation B 3.3.9 PPL Rev. 3 B 3.3.9 OPRM Instrumentation BASES ACTIONS (continued)
Note 1 has been provided to modify the ACTIONS related to affected OPRM channels. Technical Specification Section 1.3, Completion Times, specifies that once a Condition has been entered, subsequent divisions, subsystems, components, or variables expressed in the Condition discovered to be inoperable or not within limits will not result in separate entry into the Condition. Technical Specification Section 1.3 also specifies that Required Actions of the Condition continue to apply for each additional failure, with Completion Times based on initial entry into the Condition. However, the Required Actions for affected OPRM channels provide appropriate compensatory measures. As such, a Note has been provided that allows separate Condition entry for each affected OPRM channel.
B.1 Several parameter settings are essential for the proper operation of the OPRM period-based trip algorithm. The permissible values of Period Confirmation Tolerance, Averaging Filter time constant, Conditioning Filter Cutoff Frequency, and minimum operable LPRM per cell parameters are limited by the setpoint basis calculations and system transient response analysis. The Minimum and Maximum Oscillation Period settings limit the algorithm window to the cell signal resonances that can be associated with unstable thermal-hydraulic conditions.
Because the ability of the OPRM channel to perform its safety function is affected by these parameter settings, the affected OPRM channel must be considered inoperable when these conditions are not met.
Operability is evaluated for each inoperable channel and Required Actions taken in accordance with LCO 3.3.1.1.
C.1 The design objective for the Amplitude and Growth Rate Based Algorithms is to provide automatic action to limit the size of these unanticipated oscillations, thereby preventing fuel cladding damage. Several parameter settings define the function of the Amplitude and Growth Rate Based Algorithm. The OPRM design and licensing basis takes no credit for the Amplitude and Growth Rate Based Algorithm, which is provided as a defense-in-depth feature in the event of unanticipated oscillations.
(continued)
SUSQUEHANNA - UNIT 1 TRM /, B 3.3-17b -
EFFECTIVE DATE 03/22/2006
OPRM Instrumentation PPL Rev. 3 B 3.3.9 B 3.3.9 OPRM Instrumentation BASES ACTIONS C.1 (continued)
Because the ability of the OPRM Channel to perform its safety function is not affected by these parameter settings, the affected OPRM Channel need not be immediately considered inoperable when these conditions are not met.
These parameters are to be maintained for conformance with the licensing requirement of a defense-in-depth feature in addition to the licensed OPRM trip function. This is corrected by returning the parameters to conformance within 120 days of identification.
Since the Amplitude and Growth Rate Based parameters affect only the defense-in-depth response within each channel, failure to maintain the proper parameters in the channel affects only the operability of that channel.
D. 1 This Action is to be taken if the Period Based Detection Algorithm trip function is not available in accordance with LCO 3.3.1.1, and initiation of an alternate method to Detect and Suppress thermal hydraulic instability oscillations is required by the referenced LCO Required Actions. The applicable Conditions are entered as required.
E. 1 As directed from Required Action D.1, this Action provides preemptive protection through Power/Flow Map operating restrictions When operating in Region I of the Power / Flow map specified in the COLR, or when operating in Region II of the Power / Flow map specified in the COLR with less than 50% of the required LPRM upscale alarms OPERABLE, the potential for thermal-hydraulic oscillations is greatly increased and sufficient margin may not be available for operator response to suppress potential thermal-hydraulic oscillations. Therefore, the reactor mode switch must be immediately placed in the shutdown position. Action is taken immediately to place the plant in a condition where any potential for thermal-hydraulic instabilities will be terminated.
Identification of which LPRMs are Upscale can be determined by a number of methods in the control room. The most commonly used method is visual and audible observance of the LPRM Upscale Annunciator and Alarm followed with identification of the individual LPRMs feeding the annunciation/alarm. Identification of individual LPRM Upscale is possible by observance of the various Operator display assemblies and control panel monitors.
(continued)
SUSQUEHANNA - UNIT 1 TRM / B 3.3-17c EFFECTIVE DATE 03/22/2006
OPRM Instrumentation PPL Rev. 3 B 3.3.9 B 3.3.9 OPRM Instrumentation BASES ACTIONS F. 1 (continued)
As directed from Required Action D.1, this Action provides guidance for Operator action in response to thermal-hydraulic instability oscillations.
When operating in Region Ii of the Power/Flow map specified in the COLR immediate response is necessary when there are indications that thermal hydraulic oscillations are occurring as defined in the CONDITION.
LPRM upscale alarms are required to detect reactor core thermal-hydraulic instability events. The criteria for determining which LPRM upscale alarms are required is based on assignment of these alarms to designated core zones. These core zones consist of the level A, B, and C alarms in 4 or 5 adjacent LPRM strings. The number and location of LPRM strings in each zone assure that with 50% or more of the associated LPRM upscale alarms OPERABLE sufficient monitoring capability is available to detect core wide and regional oscillations. Operating plant instability data is used to determine the specific LPRM strings assigned to each zone.
Identification of which LPRMs are Upscale can be determined by a number of methods in the control room. The most commonly used method is visual and audible observance of the LPRM Upscale Annunciator and Alarm followed with identification of the individual LPRMs feeding the annunciation/alarm. Identification of individual LPRM Upscale is possible by observance of the various Operator display assemblies and control panel monitors.
G.1 As directed from Required Action D.1, this Action provides guidance for Operator action in response to operation in conditions that may lead to thermal-hydraulic instability oscillations.
When operating in Region II of the Power/Flow map specified in the COLR, the potential for thermal-hydraulic oscillations is increased and sufficient margin may not be available for operator response to suppress potential thermal-hydraulic oscillations. Therefore, action must be initiated immediately to restore operation outside of Regions II of the Power/Flow map specified in the COLR. This can be accomplished by either decreasing THERMAL POWER with control rod insertion or increasing core flow by increasing recirculation pump speed. The starting of a recirculation pump will not be used as a means to exit the excluded Regions because the starting of a recirculation pump with the plant operating above the 70% rod line is prohibited due to potential instability problems.
(continued)
SUSQUEHANNA - UNIT 1 TRM / B 3.3-17d EFFECTIVE DATE 03/27/2008
OPRM Instrumentation PPL Rev. 3 B 3.3.9 B 3.3.9 OPRM Instrumentation BASES ACTIONS H. 1 (continued)
The LPRMs provide a capability to monitor power in selected locations of the reactor core. The LPRM Upscale Alarm Instrumentation provides information concerning local power oscillations. Condition F requires a reactor scram when operating in Region II of the Power/Flow map specified in the COLR with indications that thermal hydraulic oscillations are occurring. The number and location of LPRM strings in each zone assures that with 50% or more of the associated LPRM upscale alarms OPERABLE any power oscillations which could occur would be,detected and proper actions can be taken.
Identification of which LPRMs are Upscale can be determined by a number of methods in the control room. The most commonly used method is visual and audible observance of the LPRM Upscale Annunciator and Alarm followed with identification of the individual LPRMs feeding the annunciation/alarm. Identification of individual LPRM Upscale is possible by observance of the various Operator display assemblies and control panel monitors.
A sign is posted in the Control Room to ensure that plant operators are aware of the system condition if a plant transient results in the plant entering into the instability region.
TRS TRS 3.3.9.1 Required only when the OPRM trip function is not available, this TRS ensures the combination of core flow and THERMAL POWER are within required limits to prevent uncontrolled thermal hydraulic oscillations by ensuring the recirculation loops are within the limits established by the Power
/ Flow map specified in the COLR. At low recirculation flows and high reactor power, the reactor exhibits increased susceptibility to thermal-hydraulic instability. The Power/ Flow map specified in the COLR is based on guidance provided in References 7, 8, and 9 which also provided the guidance on how to respond to operation in these conditions. The 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Frequency is based on operating experience and the operators inherent knowledge of the current reactor status, including significant changes in THERMAL POWER and core flow to ensure the requirements are constantly met.
TRS 3.3.9.2 This TRS is to be performed at the specified Frequency to ensure that the LPRM Upscale Alarm Instrumentation are maintained OPERABLE.
(continued)
SUSQUEHANNA - UNIT 1 TRM / B 3.3-17e EFFECTIVE DATE 03/22/2006
OPRM Instrumentation B 3.3.9 PPL Rev. 3 B 3.3.9 OPRM Instrumentation BASES TRS TRS 3.3.9.3 (continued)
The parameter setpoint verification surveillance compares the desired settings and setpoints to the values contained in the processor memory.
This surveillance is required to assure that the settings are maintained in accordance with the setpoint analysis. The frequency is based on the OPRM CALIBRATION frequency per SR 3.3.1.1.18.
REFERENCES
- 1. NEDO-31960-A, BWROG Long Term Solution Licensing Methodology
- 2. NEDO-31960-A, Supp. 1, BWROG Long Term Solution Licensing Methodology
- 3. NEDO-32465-A, BWROG Reactor Stability Detect and Suppress Solutions Licensing Basis Methodology and Reload Applications
- 4. Deleted
- 5. Generic Letter 94-02, Long-Term Solutions and Upgrade Of Interim Operating Recommendations for Thermal-Hydraulic Instabilities in Boiling Water Reactors
- 6. LCO 3.3.1.1, Reactor Protection System (RPS) Instrumentation
- 7. GE Service Information Letter No. 380, "BWR Core Thermal Hydraulic Stability," Revision 1, February 10, 1984
- 8. Letter, L. A. England to M. J. Virgilio, "BWR Owner's Group Guidelines for Stability Interim Corrective Action," June 6, 1994
- 9. EMF-CC-074(P)(A), Volume 4, Revision 0, "BWR Stability Analysis:
Assessment of STAIF with Input from MICROBURN-B2," November 1999
- 10. NEDC-3241OP-A, "Nuclear Measurement Analysis and Control Power Range Neutron Monitor (NUMAC PRNM) Retrofit Plus Option III Stability Trip Function" SUSQUEHANNA - UNIT 1 TRM / B 8.3-17f EFFECTIVE DATE 03/22/2006
Suppression Pool Alarm Instrumentation PPL Rev. 2 B 3.6.3 B 3.6.3 Suppression Pool Alarm Instrumentation BASES TRO The function of the Suppression Pool Instrumentation is to provide continuous monitoring of the suppression pool temperature and level. This monitoring function supplements the Operator observations and periodic Technical Specification Surveillance Requirements which require observation of the monitored parameters.
The suppression pool alarm instrumentation is designed to warn the control room operator that a limit has been reached and some compensatory action may be required. The setpoints are chosen to be consistent with the limits defined in the Technical Specifications.
Each channel of suppression pool narrow range level instrumentation consists of a transmitter, indicator and alarm circuit. This TRO only requires the alarm function to be maintained. The indicator is not required to support this function but can be used to support the performance of TRS 3.6.3.1, "Channel Check," and can be used to perform Surveillance Requirement (SR) 3.6.2.2.1.
Each channel of suppression pool temperature consists of 8 temperature detectors, as described in the Basis for SR 3.6.2.1.1, associated indicators and alarm circuits. The four alarm functions, as specified in Table 3.6.3-1, are displayed by monitors located both on the electronic unit (TX-15751 for Div. I, TX-15752 for Div II) and on the main control board (TIAH-15751 for Div. I, TIAH-15752 for Div. II). The alarm displays on both the electronic unit and main control board must be surveilled. Annunciators, tripped by the plant computer at a calculated bulk pool temperature of 880F and by the electronic unit at or below the 105 0F, 11 0°F and 120°F limits, enhance the operator's monitoring capability but are not required to be surveilled. This TRO only requires the alarm function to be maintained. The indicators are not required to support this function but can be used to support the performance of TRS 3.6.3.1, "Channel Check" and can be used to perform SR 3.6.2.1.1.
ACTIONS The Actions are defined to ensure proper corrective measures are taken in response to the inoperable components.
(continued)
SUSQUEHANNA - UNIT 1 TRM / B 3.6-4 EFFECTIVE DATE 03/27/2008
Suppression Pool Alarm Instrumentation PPL Rev. 2 B 3.6.3 B 3.6.3 Suppression Pool Alarm Instrumentation BASES (continued)
TRS The TRSs are defined to be, performed at the specified Frequency to ensure that the Suppression Pool Alarm Instrumentation Function is maintained OPERABLE.
TRS 3.6.3.1 Performance of the CHANNEL CHECK ensures that a gross failure of instrumentation has not occurred. A CHANNEL CHECK is normally a comparison of the parameter indicated on one channel against a similar parameter on other channels. It is based on the assumption that instrument channels monitoring the same parameter should read approximately the same value. Significant deviations between instrument channels could be an indication of excessive instrument drift in one of the channels or something even more serious. A CHANNEL CHECK will detect gross channel failure; thus, it is key to verifying the instrumentation continues to operate properly between each CHANNEL CALIBRATION.
Agreement criteria which are determined by the plant staff based on an investigation of a combination of the channel instrument uncertainties, may be used to support this parameter comparison and include indication and readability. If a channel is outside the criteria, it may be an indication that the instrument has drifted outside its limit and does not necessarily indicate the channel is Inoperable.
TRS 3.6.3.2' A CHANNEL FUNCTIONAL TEST is performed on each required channel to ensure that the entire channel will perform the intended function.
The Frequency of 92 days is based on the reliability analysis of Reference 1.
REFERENCES (1)
EWR 365129, Evaluation of extending SPOTMOS alarm functional test from 31 days to 92 days.
SUSQUEHANNA - UNIT 1 TRM / B 3.6-5 EFFECTIVE DATE 04/04/2007
Leading Edge Flow Meter (LEFM)
B 3.10.4 PPL Rev. 1 B 3.10.4 Section not used BASES THIS PAGE INTENTIONALLY LEFT BLANK SUSQUEHANNA - UNIT 1 TRM / B 3.10-6 EFFECTIVE DATE 03/27/2008
Leading Edge Flow Meter (LEFM)
B 3.10.4 PPL Rev. 1 B 3.10.4 Section not used BASES THIS PAGE INTENTIONALLY LEFT BLANK SUSQUEHANNA - UNIT 1 TRM / B 3.10-7 EFFECTIVE DATE 03/27/2008