Final Status Survey Final Report Phase V t'l-00t1,bC December 2006
CYAPCO FINAL STATUS SURVEY RELEASE RECORD CENTRAL PENINSULA SURVEY UNIT 9530-0001 Prepared By:
FSS Engineer Reviewed By.
S Engin r
Approved By: _____
Technical Support Manager Date:
/Q,'ý1/6 Date:
43 1(.
Date: 1/-*& /96 Revision 0
CENTRAL PENINSULA SURVEY UNIT 9530-000 1 RELEASE RECORD TABLE OF CONTENTS
- 1.
SURVEY UNIT DESCRIPTION..............................3
- 2.
CLASSIFICATION BASIS..................................................
3
- 3.
DATA QUALITY OBJECTIVES (DQO) 5
- 4.
SURVEY DESIGN............................................................
8 5..
SURVEY IMPLEMENTATION..........................................
11I
- 6.
SURVEY RESULTS........................................................
12
- 7.
QUALITY CONTROL.....................................................
15
- 8.
INVESTIGATIONS AND RESULTS....................................
16
- 9.
REMEDIATION AND RESULTS........................................
16
- 10. CHANGES FROM THE FINAL STATUS SURVEY PLAN.......... 16
- 11. DATA QUALITY ASSESSMENT (DQA)...............................
16
- 12. ANOMALIES................................................................
17
- 13. CONCLUSION..........................................
...... 17
- 14. ATTACHMENTS...........................................................
18 14.1 - Figures (6 pages including cover) 14.2 Attachment 2 - Scan Results (3 pages including cover) 14.3 Attachment 3 - Laboratory Data (84 pages including cover) 14.4 Attachment 4-DQA Results (13 pages including covers)
TOTAL 124 Revision I
CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD SURVEY UNIT DESCRIPTION Survey Unit 9530-0001 (Central Peninsula) is designated as Final Status Survey (FSS) Class 2 and consists of 5,753 m2 (1.4 acres) of uninhabited open land located approximately 2,294 feet from the reference coordinate system benchmark used at Haddam Neck Plant (HNP) (see Attachment 1). The survey unit is bounded by land Survey Unit 9530-0004. The survey unit is relatively level open space in the middle of the peninsula.
The restoration of the peninsula for FSS has removed most surface interference in the survey unit; however, there are some trees and bushes remaining in the area.
The reference coordinates associated with this survey unit are E013 through E018 by S095 through S109 (refer to License Termination Plan (LTP) Section 5.4.4).
The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may not be part of this survey unit.
The boundary of the survey unit was defined using a Global Positioning System (GPS) based on the Connecticut State Plane System North American Datum (NAD) 1927.
- 2.
CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10, "Survey Unit Classification. " The historical information, scoping analyses and characterization results provided sufficient data to designate Survey Unit 9530-0001 as Class 2 in August 2006.
The "Classification Basis Summaty" conducted for Survey Unit 9530-0001 consisted of:
a) A review of the 10CFR50.75 (g) (1) database, b) A review of the "Initial Characterization Report" and the "Historic Site Assessment Supplement,"
c) Historic and current survey records review, d) Visual inspections and a "walkdown."
A review of the 10CFR50.75(g)(1) database report identified two documents associated with this survey unit.
a) Event PIR 80-37: Contamination was documented to be present in an area outside the restricted area. Small areas of low-level contamination were found on the facility grounds through a routine survey in a normally non-radioactive area.
b) Event PIR 89-35: Contamination was identified in the 115 kV switchyard moat (Structure 111, refer to Connecticut Yankee (CY)
Drawing SK-16112-10032 sheet 2.
The source of the contamination was the discharge of approximately fifty (50) gallons of radioactive liquid using an unmonitored, unmarked drain line in the Spent Fuel Building.
Once identified, decontamination was performed in the Revision 0 3
CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD switchyard moat and an outfall area outside the Radiologically Controlled Area (RCA). However, a plant survey performed on 2/28/89 shows that some of the radioactive material was deposited along the unpaved road in this survey unit. The survey also documents that the area was excavated and surveyed when the condition was identified.
The survey documents that count rates using portable beta detection instrumentation were less then one hundred corrected counts per minute above background (100 ccpm).
A review of the "Initial and Supplemental Characterization Reports" as well as the previous "Classification Basis Summaries" provided no additional information pertinent to classification.
The survey unit had undergone FSS in the fall of 2004 and release records documenting the satisfactory completion of the FSS objectives were in preparation.
In 2006, utilities were being removed as part of the decommissioning effort on the Upper Peninsula.
Construction debris including Asbestos Containing Material (ACM) was identified and remediated. In addition to the ACM, several-objects were also identified that had detectable radioactivity. Two pieces of angle iron were located in a water utility trench in adjacent Survey Unit 9530-0004. Most of the work involved two areas adjacent to Survey Unit 9530-0001. Some of the excavated spoils from these areas were temporarily stored in Survey Unit 9530-0001 during the investigation. Based on the potential to change the final radiological status of the survey unit, another FSS was considered prudent to define the as-left radiological condition.
Soil samples were collected in 2006 to establish the radiological condition of the surface and subsurface area following removal of soil. Cs-137 was the only gamma emitting radionuclide reported in concentrations with the potential for exceeding the screening criteria. Therefore, the previous FSS data and statistical parameters were used for the survey design. Statistical quantities from the previous FSS survey are provided in Table 1.
Minimum Observed Concentration (pCi/g):
6.39E-02 Maximum Observed Concentration (pCi/g):
3.15E-01 Mean (pCi/g):
1.61E-01 Median (pCi/g):
1.15E-0I Standard Deviation (pCi/g):
9.16E-02 Revision 0 4
CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD The FSS Engineer performed a visual inspection and walk-down during August 2006 to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions.
This survey area is affected by existing groundwater (reference CY memo ISC.06-024) which will be a source of dose from residual radioactivity, as discussed in Section 3 under the Data Quality Objectives.
Based upon the historical information and the results of radiological surveys performed during characterization, it was concluded that there was a low probability for residual radioactivity to be present in this survey unit in concentrations greater than the Operational Derived Concentration Guideline Levels (DCGLs) justifying a final survey unit classification of Class 2 (refer to Section 3).
- 3.
DATA QUALITY OBJECTIVES (DQO)
FSS design and planning used the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5.1 -11, "Preparation of Final Status Survey Plan, " and the "Multi-Agency Radiation Survey and Site Investigation Manual" (MARSSIM). A summary of the main features of the DQO process are provided herein.
The DQO process incorporated hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is technically known as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection. In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would indicate that residual activity within the survey unit does not exceed the release criteria. Therefore, the survey unit does satisfy the primary objective of the FSS plan.
The primary objective of the FSS plan was to demonstrate that the level of residual radioactivity in Survey Unit 9530-0001 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).
A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity. This is done through the development of DCGLs. The DCGLs represent average levels of radioactivity above background levels and are presented in terms of surface or mass activity concentrations. Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL), existing Revision 0
-5 Revision 0 5
CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD groundwater radioactivity and future groundwater radioactivity that will be contributed by building basements and footings..
The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity.
Equation I shows the mathematical relationship between the three (3) components and the total dose.
Equation 1 HTotal--Hsoii+H-ExistngGw +HFutuzreGW The total dose under the LTP criteria is twenty-five (25) mrem/yr TEDE from all three (3) components.
The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for CY is nineteen (19) mrem/yr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from soil must be reduced when using the existing and future groundwater dose values discussed above.
This survey area is affected by existing groundwater (reference CY memo ISC 06-024).
Therefore, the dose contribution from existing groundwater is bounded by two (2) mrem/yr TEDE.
This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no buried concrete foundations or footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater, the third dose component is, therefore, zero (0) mrem/yr TEDE.
Equation 2 19 mrem/yrTotal = 17 mrem/yrsoil + 2 mremnyrExisting GW+ 0 mremlyrFutureGW The allowable dose for soil in this survey unit is seventeen (17) mremryr TEDE as shown by Equation 2 above.
The concentration of residual radioactivity resulting in seventeen (17) mrem/yr TEDE is designated as the Operational DCGL, and has been established for the radionuclides of concern as provided in Table 2.
Revision 0 6
CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD
- -*:a
! e-uc ieSeli*Bse eSl iOpeatio naIIW.CG~s*h*
H-3 4.12E+02 2.80E+02 1.65E+01 C-14 5.66E+00 3.85E+00 2.26E-01 Mn-54 1.74E+01 1.18E+01 6.96E-01 Fe-55 2.74E+04 1.86E+04
- 1. 1 OE+03 Co-60 3.81E+00 2.59E+00 1.52E-01 Ni-63 7.23E+02 4.92E+02 2.89E+01 Sr-90 1.55E+00 1.05E+00 6.20E-02 Nb-94 7.12E+00 4.84E+00 2.85E-01 Tc-99 1.26E+O1 8.57E+00 5.04E-01 Ag-108m 7.14E+00 4.86E+00 2.86E-01 Cs-134 4.67E+00 3.18E+00 1.87E-01 Cs-137 7.91E+00 5.38E+00 3.16E-0I Eu-152 1.01E+01 6.87E+00 4.04E-01 Eu-154 9.29E+00 6.32E+00 3.72E-01 Eu-155 3.92E+02 2.67E+02 1.57E+01 Pu-238 2.96E+O 1 2.01E+01 1.1 8E+00 Pu-239/240 2.67E+01 1.82E+01 1.07E+00 Pu-241 8.70E+02 5.92E+02 3.48E+O1 Am-24 1 5) 2.58E+01 1.75E+0O1 1.03E+00 Cm-243/244 2.90E+01 1.74E+01
- 1. 1 6E+00 (1) Bold indicates those radionuclides considered to be Hard-to-Detect (HTD)
(2) The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to 25 mrem/yr TEDE (3) The Operational DCGL is equivalent to 17 mrem/yr TEDE (4) The required MDC is equivalent to I mrem/yr TEDE (5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD); the preferred result is the alpha spectroscopy's when both analyses are performed Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability.
Soil samples were collected in 2006 to establish the radiological condition of the surface and subsurface area following removal of soil.
Cs-137 was the only gamma emitting radionuclide reported in concentrations with the potential for exceeding the screening criteria.
The previous FSS data and statistical parameters were used for the survey design and are provided in Table 1.
Instrument DQOs included a verification of the ability of the survey instrument to detect the radiation(s) of interest relative to the DCGL. Survey instrument Revision 0 7
Revision 0 7
CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD response checks were required prior to issue and after the instrument had been used. Control and accountability of survey instruments was required to assure the quality and prevent the loss of data.
As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. Results reported as less than Minimum Detectable Concentration (MDC) were not accepted for FSS. Sample report summaries included unique sample identification, analytical
- method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.
- 4.
SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards, Guidance for preparing FSS plans is provided in Procedure RPM 5.1-11, "Preparation of Final Status Survey Plans".
The FSS plan uses an integrated sample design that combines scanning surveys and sampling which can be either random or biased.
The DQO process determined that Cs-137 would be the radionuclide of concern in survey unit 9530-0001 (refer to Section 3). Other radionuclides identified during this FSS would be evaluated to ensure adequate survey design.
Surrogate DCGLs were not required for this survey unit based the previous FSS of this survey unit and via screening under LTP Section 5.4.7.2, "Gross Activity DCGLs".
Radionuclide screening or de-selection is a process where an individual radionuclide or aggregates may be considered insignificant.and eliminated from the FSS. The criteria for de-selection are concentrations less than 5% for individual radionuclides and less than 10% for aggregates.
The Elevated Measurement Comparison (EMC) did not apply to this survey unit since it is a Class 2 area and discrete, elevated areas of contamination were not expected.
The Sign Test was selected as the non-parametric statistical test. The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation.
This approach was conservative since it included background Cs-137 as part of the sample set.
The number of soil samples for FSS was determined in accordance with Procedure RPM 5.1-12, "Determination of the Number of Surface Samples for Final Status Survey." The Lower Bound, of the Gray Region. (LBGR) was set in accordance with Procedure RPM 5.1-11 to 5.26 to maintain the relative shift (A/c) in the range of 1 and 3. The resulting Adjusted Relative Shift was 2.0. A Prospective Power Curve was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of the MARSSIM in support of the decommissioning license termination rule (10 CFR 20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design.
Revision 0 8
Revision 0 8
CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD The survey design specified fifteen (15) surface soil samples for non-parametric statistical testing and two (2) samples at biased locations.
- The grid pattern and locations of the soil samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, "Identifying, and Marking Surface Sample Locations for Final Status Survey."
Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A systematic triangular grid pattern with a random starting point was selected for sample design, which is appropriate for a Class 2 area.
Judgmental sampling was included as a feature of this survey design to account for any anomalies potentially identified in the field.
Sample locations were identified using AutoCAD-LT, a commercially available plotting software package with coordinates consistent with* the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 3.
9530-0001-OOIF 235541.75 670285.43 9530-0001-002F 235541.75 670353.87 9530-0001-003F 235541.75 670422.31 9530-0001-004F 235541.75 670490.75 9530-0001-005F 235482.48 670388.09 9530-0001-006F 235482.48 670456.53 9530-0001 -007F 235482.48 670524.97 9530-0001-008F 235482.48 670593.41 9530-0001-009F 235423.21 670490.75 9530-0001-O10F 235423.21 670559.19 9530-0001-01 IF 235423.21 670627.63 9530-0001-012F 235423.21 670696.07 9530-0001-013F 235423.21
- 670764.51 9530-0001-014F 235363.93 670661.85 9530-0001-015F 235363.93 670730.29 9530-0001-016F 235442.18 670580.76 9530-0001-017F 235463.77 670617.68 Procedure RPM 5.
1-11 specifies that 5% of the samples are required to be selected for HTD analysis. Two (2) soil samples, or about 10% of the number of samples that would be used for non-parametric statistical testing were Revision 09 9
CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD randomly selected for HTD radionuclide analysis using the Microsoft Excel "RANDBETWEEN" function. Each sample was sent off-site for a full suite analysis of the HTD radionuclides specified in the LTP, Table 2-12, "Radionuclides Potentially Present at Haddam Neck Plant" and as provided in Table 2.
The implementation of quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey," included the collection of two (2) soil samples for "split sample" analysis by the off-site laboratory. These locations were selected randomly using the Microsoft Excel "RANDBETWEEN" function. The number of quality control soil samples was about 10% of fifteen (15) samples.
The LTP specifies that scanning will be performed along with a combination of systematic and judgmental measurements (samples) for a Class 2 land area and should cover between 10% to 100% of the area.
The fraction of. scanning coverage was determined during the DQO process with the total amount and location(s) based on the likelihood of finding elevated activity during FSS.
Based on the historical site assessment, the characterization data available, and the use of the survey unit to store spoils from remediation, it was determined that scanning was required in three (3) separate areas. The total surface area to be scanned was approximately 15% of the survey unit. A map of the scan grid locations is provided in Attachment 1.
For this Class 2 survey unit, the "Investigation Level" for area scanning and soil sample measurement results are those levels specified in LTP, Table 5-8. Table 4 provides a synopsis of the survey design.
Survey Unit Land Area 5,753 m2 Based on AutoCAD-LT Type 1 and Type 2 errors were 17 0.05, sigma was 0.092 pCi/g, Number of Measurements (15 systematic grid) the LBGR was adjusted to 5.2 (2 biased) to maintain Relative Shift in the range of I and 3 Grid Spacing 21.0 m Based on triangular grid Administratively set to achieve Operational DCGL 5.38 pCi/gCs-137 17 mrem/yr TEDE ()
The Operational DCGL meets Soil Investigation Level 5.38 pCi/g Cs-I137 the LTP criteria for a Class 2 survey unit Revision 0 10 Revision 0 10
CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD
-TAble 4S rnossutees Des ar Feature Dýsi-rieia-Bsi Scan Survey Area Approximately 15%
The LTP requires >10% area Coverage of the area coverage for Class 2 survey units Detectable over Administratively set to achieve Scan Investigation Level background 17 mrem/yr TEDE (
(1) The allowable dose for soil in this survey unit is 17 mrem/yr TEDE as the bounding dose from existing and future groundwater has been established based on field data (reference CY memo ISC 06-024)
- 5.
SURVEY IMPLEMENTATION Final status survey field activities were conducted under Work Plan and Inspection Record (WP&IR) 2006-0038.
The WP&IR package included a detailed FSS plan, job safety analysis, job planning checklist and related procedures for reference.
Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey. The "Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.
Three (3) scan areas were established that constituted approximately 15% of the surface area of Survey Unit 9530-0001.
Grid lines, one meter wide, were painted on the ground of each of the three (3) scan areas. A background survey was performed around the survey unit and it was determined that, using a Eberline E-600 with a SPA-3 sodium iodide detector, background ranged from 6,200 counts per minute (cpm) up to 8,100 cpm.
The scan areas were established and each area was scanned for elevated readings (see Attachment 2 for all scan results). Scanning was performed with an Eberline E-600 using a SPA-3 sodium iodide detector.
The E-600 was operated in the rate-meter mode and used with audio response. The probe was positioned as close to the ground as possible and was moved at a scan speed of about 0.5 meters per second.
Approximately 15% of the survey unit was scanned.
Measurement locations were identified in North American Datum (NAD) 1927 coordinates using GPS coordinates; sample locations were identified and marked with a surveyor's flag or paint for identification.
At each sample location, a one (1) meter radius around the sample flag or paint mark was scanned for elevated radiation levels.
Fifteen (15) surface soil samples were collected and packaged in accordance with Haddam Neck Plant (HNP) Procedure RPM 5.1-3, "Collection of Sample Media for Final Status Survey" and FSS design.
Samples were controlled, transported, stored, and transferred to the off-site laboratory using Chain-of-Custody (COC) protocol in accordance with Procedure RPM 5.1-5, "Chain of Custody for Final Status Survey Samples."
Revision 0 I1I
CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD Two (2) samples (9530-0001-003F and 9530-0001-008F) were randomly selected for HTD radionuclide analysis.
The implementation of survey specific quality control measures included the collection of two (2) samples (9530-0001-006F and 9530-0001-014F) for "split sample" analysis.
- 6.
SURVEY RESULTS All field survey activities were conducted between September 8, 2006 and September 15, 2006.
The sample locations identified in the FSS plan were scanned over approximately a one (1) meter radius for elevated radiation levels.
Table 5 provides an overview of the scan results for sample measurement locations.
Scan results are provided in Attachment 2.
Ta:ible, 5 -Scan Results:for $Ample Me6asuremenit ocations.
. "Hihs Log g
% Action Level
'(2 Measurement.
Reading "
ri'
>Action Level.
Location e§.
1 6.74 8.48 NO 2
7.06 10.4 NO 3
6.55 9.25 NO
.4 8.62 8.70 NO 5
7.77 8.72 NO 6
7.53 8.63 NO 7
8.41 8.40 YES 8
7.87 9.60 NO 9
7.18 8.74 NO 10 7.87 8.93 NO 11 7.44 8.57 NO 12 7.47 8.81 NO 13 7.26 8.48 NO Revision 0 12 Revision 0 12
CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD
- k.
Ta~ble 5-Sca~nResults for Sampl!*Measurement Locations Sample Highest Logged' A to ee Measurement Reading jcio eel Action Level
)
14 7.17 8.88 NO 15 8.45 9.29 NO 16 8.27 8.70 NO 17 7.86 9.42 NO (1) The action level is based on a measurement above ambient background in accordance with the FSS plan (2) The FSS plan requires movement of the sample measurement location to the area within the 1 meter radius yielding the response above the action level Three (3) areas, that comprised approximately 15% of the total surface area for the survey unit, were scanned for elevated radiation levels.
The areas were scanned in accordance with the FSS plan on September 15, 2006.
One (1) elevated measurement location was identified during scanning. A confirmatory sample was collected at the elevated measurement location.
The sample collected at the elevated measurement location was denoted as 9530-0001-018F.
A map identifying all of the sample locations is provided in Attachment 1.
Table 6 provides an overview of the scan area survey. Scan results are provided in Attachment 2.
.~,K*,*-'Table6-ScanArea Results..,,>U,.<
Highest Eleva.ed SScan Logged Action Level Elevated Ivesti**
tion
..Area, Reading K
(kcpm)
Reading
()
"Sample k....,..., w.Identification (2)
None - no 1
7.38 8.93 elevated areas None identified 2
10.6 7.98 ER-02-01-1 9530-0001-018F None - no 3
6.99 7.73 elevated areas None identified (1) The action level is based on a measurement above ambient background (2) ER is an abbreviation associated with the barcodes used in the field where ER stands for Elevated Reading The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories, LLC, Charleston, South Carolina.
The laboratory analyzed the fifteen (15) samples collected for non-parametric statistical testing, the associated field splits, the two (2) biased samples, and the one (1) confirmatory sample using gamma spectroscopy. Gamma spectroscopy analysis was performed to the required MDCs.
Gamma spectroscopy results identified some radionuclides meeting the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty).
Revision I 13 Revision I 13
CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD Cs-137 was identified in fourteen (14) of the fifteen (15) samples collected for non-parametric statistical testing.
Cs-137 was the primary radionuclide confirming the DQOs. The mean of the gamma spectroscopic analysis results for the sample population indicated that Cs-137 was present at levels lower than the concentrations of Cs-137 found in soil at off-site locations within the vicinity of the HNP as presented in the Health Physics TSD BCY-HP-0063.
A summary of the fifteen (15) samples collected for non-parametric statistical testing results is provided in Table 7.
S.
ti ` IS----
KsiinplNumnber, 9 1 1.30E-01 0.024 9530-0001 -001F 1.30E-01 0.024 9530-0001-002F 1.27E-01 0.024 9530-0001-003F 2.59E-01 0.048 9530-0001-004F 1.31E-01 0.024 9530-0001-005F 4.85E-02 0.009 9530-0001-006F 1.21 E-01 0.022 9530-0001-007F 1.34E-01 0.025 9530-0001-008F 1.33E-01 0.025 9530-0001-009F 6.41E-02 0.012 9530-0001-O1OF 1.34E-01 0.025 9530-0001-011 F 1.06E-01 0.020 9530-0001-012F 8.50E-02 0.016 9530-0001-013F 7.29E-02 0.014 9530-0001-014F 5.47E-02 0.010 9530-0001-015F 4.15E-02 0.008 (1) The Operational DCGL from Table 2 is 5.38 pCi/g for Cs-137 to achieve 17 mrem/yr TEDE The off-site laboratory also processed two (2) samples for HTD analysis as required by the, sample plan.
The requested analyses included alpha spectroscopy, gas proportional counting, and liquid scintillation depending on the radionuclide and the measurement method. All analyses met the required MDC.
Revision 0 14 Revision 0 14
CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD As previously stated in Section 4 of this report, the criteria for de-selection of a radionuclide is a concentration that is less than 5% of the Operational DCGL for individual radionuclides and less than 10% of the Operational DCGLs for aggregates. Sr-90 and Pu-238 were the only HTDs, which by analysis, met the criteria for detection (i.e., a result greater than two standard deviations uncertainty).
The highest result for both Sr-90 and Pu-238 was <1% of the Operational DCGL.
uRA-90P238
- 40.
- a on Operationa 9530-0001-003F 8.33E-03 0.008
-1.10E-01
-0.005 9530-0001-008F 2.67E-03 0.003 1.02E-01 0.005 (1) The Operational DCGL from Table 2 is 1.05 pCi/g for Sr-90 and 20.1 pCi/g for Pu-238 to achieve 17 mnrern/yr TEDE Two (2) biased samples were collected at locations selected by FSS Supervision based on professional judgment and observation. Gamma spectroscopy analysis was performed by the off-site laboratory to the required MDC.
"Table NUJden-o Ria'"
m'- -..
u""".
Ojiik'-4aV inaI CL' 9530-0001-016F 9.61E-02 0.018 9530-0001-017F 1.82E-01 0.034 (1) The Operational DCGL from Table 2 is 5.38 pCi/g for Cs-137 to achieve 17 mrem/yr TEDE
- 7.
QUALITY CONTROL The off-site laboratory processed the split samples and performed gamma spectroscopy analysis. Thirteen percent (13%) of the samples were selected for analysis, which exceeds the 5% minimum required by the LTP. The data were evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 as detailed in HNP Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey." There was acceptable agreement between field split results for Cs-137 at location 9530-0001-006.
However, Cs-137 was not detected in sufficient quantities in the field split results at location 9530-0001-014 to evaluate in accordance with procedure. Evaluation using the reported results for K-40 resulted in acceptable agreement between the field split results at location 9530-0001-014.
The sample analysis vendor, General Engineering Laboratories, LLC, maintains quality control and quality assurance plans as part of normal operation. Refer to for data and data quality analysis results.
Revision 0 15 Revision 0 15
CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD
- 8.
INVESTIGATIONS AND RESULTS One (1) confirmatory sample was collected in scan area 2 at a location exhibiting elevated scan readings. The sample is denoted as shown in Table 6, with the sample result shown in Table 10 below.
-A A
9530-0001-018F 1.67E-01 0.031 (1) The Operational DCGL from Table 2 is 5.38 pCi/g for Cs-137 to achieve 17 mrem/yr TEDE
- 9.
REMEDIATION AND RESULTS Historically, no radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to or as a result of the FSS. Health Physics TSD BCY-HP-0078, "ALARA Evaluation of Soil Remediation in Support of Final Status Survey, " determined that remediation beyond that required to meet the release criteria is unnecessary and that the remaining residual radioactivity in soil was ALARA.
- 10.
CHANGES FROM THE FINAL STATUS SURVEY PLAN No changes were made to the FSS plan.
- 11.
DATA QUALITY ASSESSMENT (DQA)
The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "Data Quality Assessment," for completeness and consistency.
The sampling design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs. The evaluation of the Sign Test results demonstrates that the survey unit passes the unrestricted release criteria, thus, the null hypothesis is rejected.
Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 2.
The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation). The mean and median values are well below the Operational DCGL when used in conjunction with the unity rule.
Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power. Therefore, the survey unit meets the unrestricted release criteria with adequate power as required by the DQOs.
Revision 0 16 Revision 0 16
CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD For Cs-137, the range of the data, about four (4) standard deviations, was not a particularly large variation considering that the levels were essentially at existing environmental levels where such variation is to be expected.
The difference between the mean and median was -21% of the standard deviation which indicates some skewness in the data.
The data was represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot indicates positive skewness as confirmed by the calculated skew of 1.3.
All data, assessments, and graphical representations are provided in Attachment 4.
- 12.
ANOMALIES No anomalies were noted.
- 13.
CONCLUSION Survey Unit 9530-0001 has met the final DQOs of the FSS plan. The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved. Elevated Measurement Comparison and remediation was not required.
Cs-137 was used for statistical testing to determine the adequacy of the survey unit for FSS.
The sample data passed the Sign Test. The null hypothesis was rejected.
The Retrospective Power Curve generated using COMPASS shows adequate power was achieved. The survey unit is properly designated as Class 2.
The dose contribution from soil is less than I mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.
This survey area is affected by existing groundwater (reference CY memo ISC 06-024); therefore the dose contribution from existing groundwater is bounded at two (2) mremlyr TEDE.
This survey unit is not considered impacted by future groundwater radioactive contamination, as there are underground structures, systems or components containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024); therefore, thedose contribution from future groundwater is zero (0) mrem/yr TEDE.
The average total dose from residual radioactivity in this survey unit, including exposures from the three (3) components as described in Section 3, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity, will not exceed 3 mrem/yr TEDE.
Therefore, Survey Unit 9530-0001 is acceptable for unrestricted release.
Revision 0' 17 Revision 0 17
CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD
- 14.
ATTACHMENTS 14.1 Attachment 1 - Figures 14.2 Attachment 2 - Scan Results 14.3 Attachment 3 - Laboratory Results 14.4 Attachment 4 - DQA Results Revision I 18
CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD ATTACHMENT 1 (FIGURES)
so 01, RefO Ce Northlng -
2
,/1
% AN IA j-CONNE02ICU*T RERJ Connecticut Yankee Atomic Power Company L.Y Site Map With Reference To Survey Unit 9530-0001
13 12 4
11 15 Legend
" Wet Land
= Smp e Location 3
14 10 Notes 9
5 0
37.5 65 I Feet Notes Coordinates are in NAD27 Connecticut State Plane System
/
.*~<....\\
-a Connecticut Yankee Atomic Power Company Survey Unit 9530-0001 Final Status Survey Design
0.08 0.13 Legend
=Wet Lnd 0.04 0.10 0.13 Notes 0.06 0.13 0.12 0
37.5 65 SFet Notes Reported Cs.137 conc*ntratiott in PCI.g Connecticut Yankee Atomic Power Company Survey Unit 9530-0001 Final Status Survey Cs-137 Posting Plot
Scan Area 2 Legend
= Wet Land Scan Area
= Sample Location Scan Area 3 Note 0
37.5 65 Ij Fý"
Scan Area I Bakmudane from 6.2 kcp. to deter-ined by an x
~E-600 with SPA-3 7
- Probed
.7 Referto Table 6for scan ara results Connecticut Yankee Atomic Power Company Date: October2006 Created by: J. McCarthy Survey Unit 9530-0001 Final Status Survey Scan Areas' Revision: 0
Scan Area 2 Legeno
=wet
= r Land aArea lpe Location Notes 37.5 65 I~~=;
Few Notes Refer to Table 9 for biased Scan Area 1 Connecticut Yankee Atomic Power Company Survey Unit 9530-0001 Biased and Con firmatory Samples
CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD ATTACHMENT 2 (SCAN RESULTS)
Survey Release Record Sample Location Scan Results Survey Unit 9530-0001 Sample Name 9530-01-SL-00-01-0 9530-01-SL-00-02-0 9530-01-SL-00-03-0 9530-01-SL-00-04-0 9530-01-SL-00-05-0 9530-01-SL-00-06-0 9530-01-SL-00-07-0 9530-01-SL-00-08-0 9530-01-SL-00-09-0 9530-01-SL-00-10-0 9530-01-SL-00-.11-0 9530-01-SL-00-12-0 9530-01-SL-00-13-0 9530-01-SL-00-14-0 9530-01-SL-00-15-0 9530-01-SL-00-16-0 9530-01-SL-00-17-0 9530-01-ER-02-01-1 (1)
Background
7270 9080 7980 7470 7490 7410 7190 8300 7510 7680 7350 7570 7270 7640 8020 7470 8140 6800 Action Level cIPM) 8488 10441 9256 8704 8726 8639 8401 9601 8748 8931 8574 8812 8488 8888 9299 8704 9428 7978 Results Above Log Date Log Time E600 SIN Probe S/N (CPM) 6740 7060 6550 8620 7770 7530 8410 7870 7180 7870 7440 7470 7260 7170 8450 8270 7860 10600 AL 9/8/2006 9/8/2006 9/8/2006 9/8/2006 9/8/2006 9/8/2006
+
9/8/2006 9/12/2006 9/14/2006 9/12/2006 9/12/2006 9/12/2006 9/14/2006 9/14/2006 9/14/2006 9/12/2006 9/12/2006 10:05:00 10:08:00 10:16:00 10:25:00 10:32:00 10:38:00 11:01:00 8:04:00 8:06:00 8:17:00 8:24:00 8:28:00 8:01:00 7:55:00 7:58:00 10:27:00 10:17:00 1116 1116 1116 1116 1116 1116 1116 1116 1105 1116 1116 1116 1105 1105 1105 1116 1116 1006
'1006 1006 1006 1006 1006 1006 1006 1012 1006 1006 1006 1012 1012
- 1012, 1006 1006 1012
+
9/15/2006 11:28 AM 1105 (1) Elevated reading corresponds to confirmatory sample location 9530-0001-018 AL - Action Level
Survey Release Record Scan Area Results Survey Unit 9530-0001 9530-0001 SCAN AREA 1 Sample Name
Background
(CPM) 9530-01-SC-01-01-0 6220 9530-01-SC-01-02-0 7390 9530-01-SC-01-03-0 7300 9530-01-SC-01-04-0 7680 9530-01-SC-01-05-0 7240 Action Level (CPM) 7346 8618 8520 8931 8455 Results 6860 7220 7330 7380 6970 Above AL Lon Date Log Time E600 SIN Probe SIN 9/15/2006 9/15/2006 9/15/2006 9/15/2006 9/15/2006 8:20:00 8:26:00 8:32:00 8:37:00 8:43:00 1105 1105 1105 1105 1105 1012 1012 1012 1012 1012 9530-0001 SCAN AREA 2 9530-01-SC-02-01-0 6
9530-01-ER-02-01-1 6
9530-01 -SC-02-02-0 7:
9530-01-SC-02-03-0 71 9530-01 -SC-02-04-0 8
9530-01-SC-02-05-0 74 9530-01-SC-02-06-0 7,
9530-0001 SCAN AREA 3 9530-01 -SC-03-01 -0 6
9530-01-SC-03-02-0 6:
9530-01-SC-03-03-0 6
9530-01 -SC-03-04-0 6
9530-01-SC-03-05-0 6
9530-01 -SC-03-06-0 6
9530-01 -SC-03-07-0 6:
9530-01 -SC-03-08-0 6
800 800 240 030 120 600 480 7978 7978 8455 8227 9407 8845 8715 6150 10600 6120 6430 6200 7740 6530 9/15/2006
+
9/15/2006 9/15/2006 9/15/2006 9/15/2006 9/15/2006 9/15/2006 9:57:00 11:28:00 10:09:00 10:16:00 10:20:00 10:24:00 10:28:00 1105 1105 1105 1105 1105 1105 1105 1012 1012 1012 1012 1012 1012 1012 710 390 550 790 480 570 560 710 7880 7532 7706 7967 7630 7727 7717 7880 6690 6770 6280 6630 6600 6990 6210 6780 9/15/2006 9/15/2006 9/15/2006 9/15/2006 9/15/2006 9/15/2006 9/15/2006 9/15/2006 10:48:00 10:51:00 10:54:00 10:56:00 10:58:00 11:01:00 11:03:00 11:06:00 1105 1105 1105 1105 1105 1105 1105 1105 1012 1012 1012 1012 1012 1012 1012 1012 AL - Action Level
CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD ATTACHMENT 3 (LABORATORY DATA)
General Narrative 1
CASE NARRATIVE For CONNECTICUT YANKEE RE: Soil PO# 002332 Work Order: 172114 SDG: MSR#06-1276 September 27,2006 Laboratory Identification:
General Engineering Laboratories, LLC Mailing Address:
P.O. Box 30712 Charleston. South Carolina 29417 Express M/lail Delivery and Shippin :Address-2040 Savage Road Chareston, Sou. h Carolina 29407 Telephone Number:
(843) 556-8171 Summary:
Sample receipt The sample(s) For this Project arrived at General Engineering Laboratories, LLC, (GEL) in Charleston, South Carolina on September 20, 2006. All sample containers arrived without any visible signs of tampering or breakage. The chain of custody contained the proper documentation and signatures.
The laboratory received the following sample(s):
Sample ID Client Sample ID 172114001 9530-0001-OOSF 172114002 9530-0001-010F 172114003 9530-0001-0.1 IF 172114004 9530-0001-012F 172114005 9530-0001-016F 172114006 9530-0001-017F 172114007 9530-0001-01 8F 172114008 9530-0001-00 IF 172114009 9530-0001-002F GENE-RAL FH'GINEERIr'G LABORATORIES, LLC a Member of THE GEL GROUP INC.
P.O. Box 30712
- Charleston, SC 29417 - 2040 Savage Road (29407)
Phone (843) 556-8171 - Fax (843) 766-1178
- www.gel.com
172114010 172114011 172114012 172114013 172114014 172114015 172114016 1.72114017
[72114018 172114019 172 114020 9530-0001-003F 9530-0001-004F 9530-0001-005F 9530-0001-006F 9530-0001-006FS 9530-0001-007F 9530-0001-009F 95-30-0001-013F 9530-0001-014F 9530-0001-014FS 9530-0001-015F Items of Note:
There are no items of note.
Case Narrative:
Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures. Any technical or.administrative problems during analysis, data review, and reduction:are.listed below by analytical parameter.
Analytical Request:
Eighteen soil samples were analyzed for FSSGAM.
Two soil samples were analyzed for FSSALL.
Internal Chain of Custodvi Custody was maintained for the sample(s).
Data Package:
The enclosed data package contains the following sections: Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.
I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data packagehas been authorized by the Laboratory Manager or a designee, as verified by the following signature.
Cheryl Jones Project Manager GENERAt ENGINEERING LABORATORIES. LLC a Member of THE GEL GROUP, INC.
P.O. Box 30712
- Charleston, SC 29417
- 2040 Savage Road (29407)
.Phone (843) 556-8171
- Fax (843) 766-1178 - www.gel.com
List of current GEL Certifications as of 26 September 2006 Slate Alaska Arizona Arkansas California
" " Colorado Connecticut DepL of Navy Florida/NELAP Georeia Hawaii illnois Indiana Kansas Kentucky Louisiana.
Maryiand Massachusetts Michigan Nevada New Jersey New Mexico New York North C0aroina North Carolina Drinking W
......... UST-062
-- 89-0651 015 IICA GenEngLabs PH--0169 NF-SC 413 WG/15.
E87 156 E87156(FL*. ELAP)
N/A
- N/A
- 200029 C-SC-0I E-10332 90129 03046 270.
" M-SCo12 9903 SCi2
.".. scbo0 FL NELAP E8*
7 156 11501 233 45709 North Dakota R-158 Oklahoma 9904 Pennsylvania 68-00485 South Carolina 10120001/1058500101.:2000" Tennessee
- 02934 Texas TX213-2006A Texas NELAP T104704235-06-TX U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont VT87 156 Virginia Washington 00151 C*
.4 i -------
4
m Chain of Custody And upporting Documentation 5
Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00565 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:
Comments:
Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)
General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0
843 556 8171. Attn. Cheryl Jones Priority:] 30 D. Z 14 D.] 7 D. 0.3 D.
I
.. Il [I]
Container j
-n Sample Size-Sample Designation Date Time Media Type
&Type.
Comment, Preservation Lab Sample ID Code Code Code 9530-0001-008F 9-/2-44 o0,0io TS G
BP X.
v'9530-0001-01OF 5-/Z-rz coP/7 TS G
BP X
9530-0001-01IF oZ*
TS G
BP X
9530-0001-012F
,--jzo*
.+/-9/
TS G
BP X
9530-0001-016F
/0Z lo TS G
BP X
9530-0001-017F I-..z-oC
/0/3 TS G
BP X
Th NOTES: PO #: 002332 MSR #: 06- /276 SSWP# NA Z LTP QA...-
Radwaste QA
[-l Non QA Samples Shipped.Via:
Z Fed EX.
El UPS El Hand
[l Other Rill nf.adinoam#
Internal Container Temp.: _
Deg.
C Custody Sealed?
YO3 NO Custody Seal Intact?
YO NO I) Relinquis.e Date/Time
- 2) Received By.
Date/Time
)
Relinquished B/2oe oR v
B
- 3) Relinquished By Date/Time
- 4) Received By..:*.
Date/Time
Health Physics Procedure GPP-GGGR-R51 04-003-Attachment B-CY-001 Major J2 Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-572 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:
Comments:
Jack McCarthy 860-267-3924 Media Sample Container Code Type Size.
Analyticat Lab (Name, City, State):
Code
&Type AnalyicalCode General Engineering Laboratories 2040 Savage Road Charleston, SC 29407 ATT: Cheryl Jones (843-556-8171)
Priority: E] 30 D. Z 14 D. [] 7 D.
Other:
Sample Designation Date Time Comment, Preservation Lab Sample ID 9530-0001-018F 9/15/06 1130 TS G
BP X
NOTES: PO #: 002332 MSR#: Z
[
Radwaste QA 0
Non QA Samples Shipped Via:
Internal Container Fed Ex Temp.:,9..Deg. C SUPS Hand Custody Sealed?
- 1) eli quished By D te/ ime
- 2) eiv Date/Time Custody Seal Intact?
cjD t / T me Other 3)R Iquished y
Date/Timrn
- 4) Received By Date/Time
__*_Y U
- 5)
R*eq eD/Time
-6)-
R(ev eill of LadingD
/
5)Relinquished By Date/Time
- 6) Received By Date/Time
Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Chain of C~ustody Form N.20-07 Connecticut Yankee Atomic Power Company Cu No. 2006-00575 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning
.Analyses Requested Lab Use Only Contact Name & Phone:
Comments:.
Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)
General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones C/)
Priority:
30 D. Z 14 D. El 7 D. El 3 D.
Container Sample.
Size-Sample Designation Date Time Media Type
&Type Comment, Preservation Lab Sample ID Code Code Code 9530-0001-OO1F 9/8/06 1006 TS G
BP X
,q 9530-0001-002F 9/8/06 1010 TS G
BP X
'/ 9530-0001-003F 9/8/06 1016 TS G
BP X
V 9530-0001-004F 9/8/06 1026 TS G
BP X
V 9530-0001-005F 9/8/06 1033 TS G
BP X
9530-0001-006F
.9/8/06 1039 TS G
BP X
9530-0001-006FS 9/8/06 1039 TS G
BP X
NOTES: PO #: 002332 MSR #: 06-iz7T SSWP# NA E. LTP QA El Radwaste QA
[
Non QA Samples Shipped Via:
Internal Container Z. Fed Ex Temp.: __ Deg.
'-UPS C
E li Hand Custody Sealed?
YE NO I) Relinquished-B Date/Time
- 2) Received By Date/Time Custody Seal 9z 0_1
/Zc M Other Intact?
- 3) Relinquished By Date/Time
- 4) Received By Date/Time Y D0 N 0 Bill of Lading
.5) Relinquished By Date/Time
- 6) Received By Date/Time
Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major
- Chain of Custody Form Connecticut Yankee Atomic Power Company Cod r
No. 2006-00576 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:
Comments:
Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)
General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones "
Priority: 1130 D. Z 14 D. [: 7 D. El 3 D.
Container.
Sample Size-C t
rL m
Sample Designation Date Time Media Type
&Type Comment, Preservation Lab Sample ID
____Code Code Code 9530-0001-007F
.9/8/06 1101 TS G
BP X
9530-0001-009F 9/8/06 1436 TS G
BP X
'/
9530-0001-013F 9/8/06 1413 TS G
BP X
"I 9530-0001-014F 9/8/06 1417 TS G
BP, X
9530-0001-014FS 9/8/06 1417.
TS G
BP X
9530-0001-015F 9/8/06 1402 TS G
BP X
NOTES: PO #: 002332 MSR #: 06-tZ76 SSWP# NA El LTP QA
[
Samples Shipped Via:
Internal Container Z Fed Ex Temp.: _1L Deg.
Lups.c El Hand Custody Sealed?
YO NEI
- 1) Reli d By Date/Time
- 2) Received By Date/Time Custody Seal
, /*"
Oth L*
other Intact?
- 3) Relinquished By Date/Time
- 4) Received By Date/Time Y
.3 N D Bill of Lading A
- 5) Relinquished By Date/Time
- 6) Received By Date/Time
Connecticut Yankee Statement of Work for Analytical Lab Services Figure 1. Sample Check-in List CY-ISC-SOW-O01 Date/Time Received:
C, SDG#:
M t7Z Work Order Number:
VI 2- ( I /
- ~
- r 0/8 Y/'q 23 1z Shipping Cdntainer ID: ?205 V
of IV/
V.
I.
Custody Seals. oni shipping container intac
- 2.
Custody Seals dated and signed?
- 3.
Chain-of-Custoly record present?
- 4.
Cooler temperature
- 5.
Vermiculite/packing materials is:
6.'
"Number of samples in shipping container:
- 7.
Sample holding times exceeded?
- 0 Y!e, 0 Chain of Custody # 2-ý06.-
0 Yes t TNo]
Yes.[-ý'o [1 Yes M4No I I Wet [I Dry j',<
Yes [INo
- 10.
Were any anomalies identified in sample receipt?
Yes [ ] No [tj" 11.,..Description of anomalies (include sample numbers):
Sample Custodian/Laboratory:,
Date: -Y I,_
Telephoned to:
On
.By D
11
Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)
Work Order 172114 Method/Analysis Information Product:
Alphaspec Am241, Cm, Solid ALL FSS Analytical Method:
DOE.EML HASL-300, Am-05-RC Modified
- Prep Method:
Dry Soil *Prep GL-RAD-A-02 ! Method:
Analytical. Batch Number:
Prep Batch Number:
Ash Soil Prep Dry Soil Prep 572120 570846 Dry Soil Prep.GL-RAD-A-021 Batch Number:..
570843 Sample ID 172114001 172114010 1201191303 1201191304
.1.201191305 1201191306 Client ID 9530-0001-008F 9530-0001-003F Method Blank (MB) 172114001(9530-0001-008F) Sample Duplicate (DUP) 172114001(9530-0001-008F) Matrix Spike (MS)
Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-0 1 REV# 14.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
12
Quality Control (OC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 172114001 (9530-0001-008F).
QC lnformation All of the QC.samples met the required acceptance limits.
Technical Information:
Holding Time..
All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-preplRe-analysis None of the samples in this sample setrequired reprep or reanalysis.
Miscellaneous.Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from
- referenced :SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Manual Integration.
No manual integrations were performed on data in this batch.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information 13
.Product:
Alphaspec Pu, Solid-ALL FSS Analytical Method:
Prep Method:
DOE EML HASL-300, Pu-I I-RC Modified Dry Soil Prep GL-RAD-A-021 Method:
Analytical Batch Number:
Prep Batch Number:
Dry Soil Prep GL-RAD-A-021 Batch Number:
Ash Soil Prep Dry Soil Prep 572121 570846 570843 Sample ID.
17211400.1 172-114010 120119130*7 1201191308 1201191309 1I201191310.
Client ID 9530-0001 -008F 9530-0001-003F Method Blank (MB) 172114001(9530-0001-008F) Sample Duplicate (DUP) 172114001(9530-0001-008F) Matrix Spike (MS)
Laboratory Control Sample.(LCS)
SOP Reference Procedure for preparation, analysis and reportingof analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP).The data discussed in. this narrative has been analyzed in accordance with GL-RAD-A-01 I REV# 14.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (OC) Information:.
Blank Information The blank volumeis representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 172114001 (9530-0001-008F).
QC Information All of the QC samples met the required acceptance limits.
14
Technical Information:
Holding Timae All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of thesamples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformancereports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Manual integration No manual integrations were performed on data in this batch.
Additional Comments Additional comments were not required for this. sample.set.
Oualifier information Manual qualifiers were not required.
Method/Analysis Information Product:
Liquid. Scint Pu241, Solid-ALL FSS Analytical Method:
DOE EML HASL-300, Pu-I I-RC Modified Prep Method:
Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:
Dry Soil Prep Analytical Batch Number:
572122 Prep Batch Number:
570846 Dry Soil Prep GL-RAD-A-021 Batch Number:
570843 15
Sample ID Client ID 1721.14001 9530-0001-008F 172114010 9530-0001-003F 1201191311 Method Blank (MB) 1201191312 172114001(9530-0001-008F) Sample Duplicate (DUP) 1201191313 172114001(9530-0001-008F) Matrix Spike (MS) 1201191314 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL=RAD-A-035 REV# 8.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met-Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
OUalitY Control (QCQ Information:
Blank Information The blank volume is representative of the sample volume in this hatch.
Designated QC The following sample was used for QC: 172114001 (9530-0001-008F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from 16
referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Manual Integration No manual integrations were performed on data in this batch.
Additional Comments Additional comments were not required for this sample set.
Qualifier information.
Manual qualifiers were not required.
Method/Analysis Information Product:
Analytical Method:
Prep Method:
Analytical Batch Number:
Prep Batch Number:
GammaSolid-FSS GAM & ALL FSS 226 Ingrowth Waived EML HASL 300, 4.5.2.3 Dry Soil Prep 574334 570843 17
Sample ID 172114001 172114002 172114003 172114004 172114005 172114006 172114007
.1721.14008
.172114009 172114010 172114011
.172114012 1721140.13 172114014 17211i4015 172114016.
172114017 172114018
.172114019
.17211.4020 12011.96533
.1201196534 1201196535 Client ID 9530-0001-008F 9530-0001-OIOF 9530-0001-01 IF 9530-0001-012F 9530-0001-016F 9530-0001-017F 9530-0001 -018F 9530-00017001 F 9530-0001-002F 9530-0001-003F 9530-0001-004F 9530-0001-005F 9530-0001-006F 9530-0001 w)06FS 9530-0001-007F 9530-0001-009F.
9530-0001-013F 9530-0001-014F 9530-0001-014FS 9530-0001-015F Method Blank (MB) 172114006(9530-00017 017F) Sample Duplicate (DUP)
Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP)- The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 12.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QC) Information:
Blank Information The blank volume is representative of the sa'mple" volume in this batch.
Designated QC The following sample was used for QC: 172114006 (9530-0001-017F).
18
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information.
All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis
.None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Infoirmation:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional conmments were not required for this sample set.
Qualifier information Qualifier UI Ul Reason Analyte Sample Data rejected due to interference.
Data rejected due.to low abundance.
Manganese-54 Cesium-134
.172114013 172114001 172114002 172114006 172114012 172114013 172114015 172114019 172114017 Cobalt-60 NiobiUm-94
. 1201196534 U1 Data rejected due to no valid peak.
Method/Analysis Information Bismuth-212 172114005 19
Product:
GFPC, Sr9O, solid-ALL FSS Analytical Method:
EPA 905.0 Modified Prep Method:
Dry Soil Prep GL-RAD-A-021 Method:
Analytical Batch Number:
Prep Batch Number:
Dry Soil Prep GL-RAD-A-021 Batch Number:
Ash Soil Prep Dry Soil Prep 571177 570846 570843 Sample ID 172114001 172114010 1201189312
- 12011893.13 120.1189314 1201 189315 Client ID.
9530-000 1 -008F 9530-0001-003F Method Blank (MB) 172114001(9530-0001-008F) Sample Duplicate (DUP)
.172114001(9530-0001-008F) Matrix Spike (MS)
Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with. GL-RAD-A-004 REV# 10.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
0uality Control (QC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
I Designated QC The following sample was used for QC: 172114001 (9530-0001-008F).
QC Information 20
All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample. Re-prep/Re-analysis.
None of the samples in this sample set required reprep or reanalysis.
Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.
- Miscellaneous Information:
NCR Documeentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Oualifier information Manual qualifiers were not required.
Method/Analysis Information
.Product:
Liquid Scint Tc99, Solid-ALL FSS Analytical Method:
DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number-:
570932 Sample ID Client ID 172114001 9530-0001-008F.
172114010 9530-0001-003F 1201188784 Method Blank (MB) 1201188785 172114001(9530-0001-008F) Sample Duplicate (DUP) 1201188786 172114001(9530-0001-008F) Matrix Spike (MS) 1201188787 Laboratory Control Sample (LCS) 21
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC asStandard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable.and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QC) Information:
Blank Information The blank volume isrepresentative of. the samplevolumes in this batch.
- Designated QC The following sample was used for QC:. 172114001 (9530-000.1-008F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis The batch was recounted due to a suspected blank false positive.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
22
Qualifier information Manual qualifirs were not required.
Method/Anatysis Information Product:
Analytical Method:
Liquid Scint Fe55, Solid-ALL FSS DOE RESL Fe-1. Modified Prep Method:
Dry Soil PrepGL-RAD-A-021 Method:
Analytical Batch Number:
Prep Batch Number:
Dry SoiIP'ep GL-RAD-A-021 Batch Number:
Ash Soil Prep Dry Soil Prep 570929 570846 570843 Sample ID 172114001 172114010.
1201188775 1201188776 1201188777 1201188778 Client ID
- 9530-o00l-008F
- 953070001-003F Method Blank (MB) 172114010(9530-000.1-003F) Sample Duplicate (DUP) 172114010(9530-0001-003F) Matrix Spike (MS)
Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating.Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting somuces were prepared in the same geometry as the calibration standards.
Oualitv Con trol WC) Information:
Blank Information The blank volume is representative of the sample volumes in this batch.
23
Designated QC The following sample was used for QC: 172114010 (9530-0001-003F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
PreparationInformation A
AIl preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Samples 1201.188775. (MB) and 1721 14001. (9530-0001-008F) were recounted due to the quench
'number being outside the calibration range.:
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may. deviate-from referenced.SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Oualifier information Manual qualifiers were not required.
Miethod/Analysis Information Product:
Liquid Scint Ni63, Solid-ALL FSS Analytical Method:
DOE RESL Ni-I, Modified Prep Method:
Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:
Dry Soil Prep Analytical Batch Numben.
570930 Prep Batch Number:
570846 Dry Soil Prep GL-RAD-A-021 Batch Number:
570843 24
Sample ID Client ID 172114001 9530-0001-008F 172114010 9530-0001-003F 1201188780 Method Blank (MB) 1201188781 172114010(9530-0001-003F) Sample Duplicate (DUP) 1201188782 172114010(9530-0001-003F) Matrix Spike (MS) 1201188783 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8..
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources Were prepared in the same geometry as the calibration -standards.
Quality Control (OC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample wasused for QC: 172114010 (9530-0001-003F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-preplRe-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from 25
referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product:
Analytical Batch Number.
Sample ID 172114001 172114010
- 1201.188788 1201188789
.1201188790
.9530-0001-008F 9530-0001-003F
.Method Blank (MB.)
172114001(9530-0001-008F) Sample Duplicate (DUP) 1721.14001(9530-0001-008.F) Matrix Spike (MS)
Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative hasbeen analyzed in accordance with GL-RAD-A-002 REV# 13.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
26
Designated QC
- The following sample was used for QC: 172114001 (9530-0001-008F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
- Holding Time.
All.sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-preplRe-analysis.:.
None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments.
Additional comments were not required for this sample set.:
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product:
Liquid Scint C14, Solid AII,FSS Analytical Method:
EPA EERF C-01 Modified Analytical Batch Number:
570934 Sample ID Client ID 172114001 9530-0001-008F 172114010 9530-000l-003F 1201188792 Method Blank (MB) 1201188793 172114010(9530-0001-003F) Sample Duplicate (DUP) 1201188794 172114010(9530-0001-003F) Matrix Spike (MS) 1201188795 Laboratory Control Sample (LCS) 27
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before.the expiration date(s).
Sample Geometry All counting souices were prepared in the same geometry as the calibration standards..
Quality Control (0C0 Information:"
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC
- The following sample was used for QC: 172114010 (9530-0001-003F).
QC Information All of the' QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information.
All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
28
Oualifier information Manual qualifiers were not required.
Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative..
Review Validation:
GEL requires all analytical data to be verified by a qualified data validator. In addition, all data
.designated for CLP or CLP-like packaging will receive a third level validation upon completion.of the data package.
The foflowing data. validator verified the information presented in this case narrative:
A AA.
lhlLa4n Reviewer/Date:
29
SAMPLE DATA
SUMMARY
30
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANK001 Connecticut Yankee Atomic Power Co.
Client SDG: MSR#06-1276 GEL Work Order: 172114 The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Analyte isa surrogate compound U
Analyte was analyzed for, but.not detected above the MfDL, MDA, or LOD.
UI Gamma SpectrOscopyiUncertain identification ND The analyte concentration is not detected abovc the detection limit.
The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.
Where the analytical method has been performed under NELAP certification, the analysis has met all of.. the.
requirements of the NELAC standard. unless qualified on the Certificate of Analysis.
This data. report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.
Reviewed by 31
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis
.Company:
Connecticut Yankee Atomic.Power Address:
362 Injun Hollow Rd East Hampton. Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils.PO# 0012332.
Report Date:
October 4, 2006 Client Sample ID:
9530.-0001408F Project:
YANKOI204 Sample ID:
172114001 Client lb:
YANK00 Matrix:
TS.
Vol. Recv.:
Collect Date:
2-SEP-06 Receive Date:
20-SEP-06 Collector:
Client Moisture:
.17.4%
Parameter Qualifier Result Uncertainty.
LC TPU MDA Units DF Analyst Date Time Batch Mt Rad Alpha Spec Analysis Aiphaspec Aiu24 1,. Cm, Solid ALL FSS Americium-241 1 U
0.08.64 Curium-242 U!
0.00
+
Curium-243/244 U
0.0664 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U
0.102 Pfutonium-239/240 U
.0.062 Liquid Scint P,241, Solid-ALL FSS Plutonium-241 U
.6.10 Rad Gamma Spec Analysis Gamao.Solid-FSS GAM & ALL FSS 226 Ingrowti Waived Actinium-228 0.837 Americium-241 U -0.00443 BismtIth-212 0.605 Bismuth-214 0.635 Cesium-134 Ut 0.00 Cesium-137 0.133 Cobalt-60 U
0.0125 Europium-152 U
-0.0255 H
Europium-154 U -0.0496 Europium-.155 U
0.0653 Lead-212 0.816 Lead-214 0.666 Manganese-54 U
0.0204 Niobitim-94 U
0.00376 Potassium-40 12.7 Radium-226 0.635 Silver-108m U 0.000126 Thallium-208 0.238 Rad Gas Flow Proportional Counting
+41-0.105
.1-0.0553 4/-0.0911 0.0409
+/-0.106 0.00 +/-0.0553 0.0334 +/-0.0915 0.153 0.0765.
0.138 0.118 0.101 pCi/g pCi/g 1-0.0996 0.0285
.+/-0.100
+/-0.077.
.ý0.0202. +/-0.0773
+/-8.99 7.27.
+/-9.01 15.3 pCi/g
+I-0.199
+/-0.117
+/-0.281
+/-0.114
+/-0.0308
+/-0.0359 1-0.0201
/-0.0596
/-0.0802
/-0.0758
/-0.0879
+/-0.104 4-0.0255
+/-0.0207
+/-1.23
+/-0.114
+!-0.0199 F/-0.0479 0.0592 0.0646 0.150 0.0342 0.0246 0.0188 0.0184 0.0506 0.0523 0.0553
.0.0301 0.0355 0.0225 0.0176 0.159 0.0342 0.0171 0.0198
+1-0.199
+1-0.117
+/-0.281
+/-0.114
+/-0.0308
+/-0.0359
+/-0.0201
+/--0.0596
+/-0.0802
+/-0.0758
+1-0.0879
+/-0.104
+1-0.0255
+/-0.0207
+/-1.23
+1-0.114
+1-0.0199
+/-0.0479 0.129 0.133 0.319 0.0727 0.0522 0.0401 0.0407
.0.106 0.115 0-114 0.0625 0.0746 0.0478 0.0375 0.357 0.0727 0.0362 0.0419 0.0111 pCi/g pCi/g-pCiJlg pCi/g-pCilg pCi/g pCi/g pCi/9 pCi/g pCi/g-pC/g.
pCi/2 pCi/g1 pCi/g.
pCi/gz pCi/g pci/g-TCI 09/28/06 1156 572120 TCI 09/28/06 0935 572121 TCI 09/29/06 2158 572122 MJH1 10/02/06 0545 574334 Z
KSDI 09/29/06 2335 571177 f
DFAI 09/25/06 0210 570933 f
GFPC. Sr90, solid-ALL FSS Strontium-90 U
0.0(
Rad Liquid Scintillation Analysis LSC, Tritium Dist. Solid-HTD2,ALL FSS Tritium U
076
+/-0.00637 0.00516 +/-0.00637 5.59
+1-7.85 6.93
+/-7.85 14.8 pCL/g 32
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company.:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East. Hampton. Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils P0# 002332 Report Date:
October4,2006 Client Sample ID:
.Sample ID:
9530-0001 -08F 172114001 Proiect:
YANKO1204..
Client ID:
YANK001.
Vol.'Recv.:
Parameter Qualifier Result Uncertainty Rad Liquid Scintillation Analysis Liquid Stini C14, Solid AIl, FSS Carbon-14 U 0.005 33
+/--0.0803 Lquid Scint Fe55, Solid-ALL FSS Iron-55 U
3.66
+1-45.4
- Liquid Scin Ni63M Solid-ALL FSS Nickel-63 U
.4:44
+/-10.8 Liquid Scinr.Tc99, Solid-ALL FSS Technetium:m99.
U 0.0384
+/-0.285 LC TPU MiIDA Units DF Analyst Date Time Batch Mit 0.0671 +/-0.0803 31.9
+/-45.4 8.84
+/-] 0.8 0.238
+/-0.285 0.142
- 66.3 pCi/ga
- pCilg, AXD2 09/23/06 1427 570934 MXPI 10/03/06 0521 570929 1
MXPI 09/25/06 1618 570930 I
KXRI 091291u0 1617 570932 1
18.6.: :.
pCi/g 0.491 pCi/g.
The following Prep Methods were performed Method Description Analyst
" Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09/20/06 1528 570843 The following Analytical Methods were performed Method Description I
DOE EML HASL-300, Am-05-RC Modified 2
DOE EML HASL-300, Pu-I I-RC Modified 3
DOE EML HASL-300, Pu-I I-RC Modified 4
EML HASL 300,4.5.2.3 5
EPA 905.0 Modified 6
EPA 906.0 Modified 7
EPA EERF C-0I Modified 8
DOE RESL Fe-I, Modified 9
DOE RESL Fe-I, Modified 10 DOE RESL Ni-I, Modified I I DOE EML HASL-300, Tc-02-RC Modified 12 DOE EML HASL-30D, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%
Acceptable Limits Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL Fý GFPC. Sr90. solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS 92 102 96 89 74 (15%-125%)
(15%-125%)
(25%-125%)
(25%-125%)
(15%-125%)
33
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424-Report Date: October 4, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0001--008F Proiect:
YANKO 1204 Sample ID:
172114001 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU NIDA Units DF Analyst Date Time Batch Mt Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 73 (25%-125%)
Carrier/Tracer Recovery Liquid Scint.Tc99. Solid-ALL. FS 75 "
. (15%-125%)
Notes:
The Qualifiers in this report:are defined as follows:
A quality control analyle recovery is outside of specified acceptance criteria Result is less than value reported.
Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDCor tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MvIDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The abovc sample is reported on a dry weight basis.
34
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com*
Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: October 4, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530--)001-01 OF 1727114002 TS I2-SEP-.06 20-SEP--06 Client 20:6%
Proiect:
YANKO1204.
Client ID:.
YANKOO I Vol. Recv.:
Parameter Qualifier.
Result Uncertainty LC TPU MIDA Units DF Analyst Date Time Batch Mtr Rad Gamma Spec Analysis Ganuna.Solid-FSS GAM & ALL FSS 226 Ingrowth Waived.
- Actinium-228 Americium-24 I
" Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-209 0.708 U
-0.027 0.501 0.637 U1 0.00 0.134 U -0.00423 U
0.00262 U -0.00925 U
0.0469 0.825 0.745 U
0.00196 U
-0.004 13.4 0.637 U 0.000472 0-258
+--0.178.
+./-0.125
+÷-0.263
+/-0.0916
+/-0.0379
+/-0.0319
+/-0.0199
+/-0.0477
+/-0.0555
+/-0.0598
+/-0.0608
+/-0.0721
+/-0.0197
+/-0.0166
+/-0.858
+/-0.0916
+/-0.0173
+/-0.0406 0.0507 0.0897 0.114.
0.0323 0.0214 0.0163 0.0165 0.0407 0.0463 0.0524 0.0233 0.0279 0.0166 0.0139 0.155 0.0323 0.0145 0.0165
.+/-0.178
+/-0.125
+A-0.263
+/-0.0916
+/-0.0379
.4-0.0319
- +/-0.0199
+/-0.0477
+/-0.0555
+!-0.0598
+/-0.0608
+/-0.0721
+/-0.0197
+/-0.0166
+/-0.858
+/-0.0916
+/-0.0173
+/-0.0406 0.108 0.185 0.242 0.0675 0.0447 0.0343 0.0356:.
0.0849 0.0997 0.108 0.0484 0.0584 0.0351 0.0294 0.336 0.0675 0.0303 0.0347 pCij-pCi/0g pCi/g pCi/g0 pCilg pCi/g pCilg pCi/g pCilk pCL'g1 pCr/g0 pCi/so pCi/g" pCi/.g MJHI. 10/02/06 0545 574334 1
The following Prep Methods were perrormed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09/2-0/06 1536 570843 The following Analytical Methods were performed Method Description EML HASL 300,4.5.2.3 Notes:
The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 35
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4. 2006
Contact:
Mr. Jack McCarthy P'oject:
Soils PO# 002332 Client Sample ID:
9530-0001-010F Proiect:
YANK01204 Sample ID:
172114002 Client ID:
YANK001 Vol. Recv.:
Parmeter Qualifier Result Uncertainty LC TPU NDA Units DF Analyst Date Time Batch MI
>" Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Tar(get analyte was detected in the associated blank BD Results are either. below. the MDC or tracer recovery is low C
Analyte has been conFir-med by GC/MS analysis D
Results:are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed.for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy-Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +I-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
3'6
GENERAL ENGINEERING. LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd
Contact:
Project;.
East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date:
October 4, 2006 Client Sample]D:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0001-01 !F.
172114003
- TS I 12-SEP-06 20-SEP-06 Client 11.2%
Proiect:
YANKO 1204 Client ID:
YANK01 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MIDA Units DF Analyst Date Time Batch Mt, Rad Gamma Spec Analysis Ganuna Solid-FSS GCAM &ALL FSS 226 Ingrowth."
- . Waii'ed.
Actinium-228 0.816
+1-0.157
.Am.ericiuhim24l
-0.0165 '
0.0808 Bismuth-212 0.561
-+/-0.285 B ismuth-214 0-596
+/-0.0795 Cesium-134 U
0.0341
+/-0.0241 Cesium-137 0.106
+1-0.0332 Cobalt-60 U
0.0186
+/-0.019.
Europium-152.
U
-0.0191
+/--0.0484 Europium-154 U
0.00749
+/-0.0603 Europium-155 U
0.0765
+/-0.0734 Lead-212 0.826
+/-0.0624 Lead-2 14 0.717
+1-0.0882 Manganese-54 U
0.00106
+/-0.0198 Niobium-94 U
0.0268
+/-0.0248 Potassium-40 13.1
+/-0.809 Radium-226 0.596
+/-0.0795 Silver-108m U -0.00573
+/-0.0161 Thallium-208 0.259
+/-0.0534 0.0536 0.0626
.0.109 0.0286 0.0202 0.0155
- 0. 0171 0.0406 0.0501 0.0456 0.0286 0.0295 0.0169 0.0157 0.110 0.0286 0.0133 0.0162
.+-0. 157.
+/-0.0808
+/-0.285
+/-0.0795
+/-0.0241
+/-0.0332
+/-0.019
+/-0.0484
+/-0.0603
+/-0.0734
+1-0.0624
+/-0.0882
+/-0.0198
+/-0.0248
+/-0.809
+/-0.0795
+/-0.0161
+/-0.0534
- 0.11.5 "0129
- 0.234 0.0604 0.0426
" 0,033 0.037
.0.0851 0.108 0.0946 0.0591
" 0.0618 0.0358 0.0332 0.249 0.0604 0.0281 0.0341 pCi/g pCi/g pCL'gQ pCilg-pCi/ga pCi/g pCi/g1 pCi/g-pCi/g' pCiLR pCilg-pCui/.
pCilga pCi/g pCilcg pCi/8 pCi/g.
MJHI 10/02/06 05.45 574334 1
The following Prep Methods were per'ormed Method Description Analyst Dale Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09/20/06 1536 570843 The following Analytical Methods were performed Method Description I
EML HASL 300,4.5.23 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 37
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleslon SG 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power
- Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4, 2006
Contact:
Mr. Jack McCarthy Project::
Soils PO# 002332 ClientSampleID:
9530-0001-01 F Project:
YANK01204 Sample ID:
172114003 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty
'LC ThU rVDA Uniis DF Analyst Date Time Batch Mit Result is greater than value reported A
- TheTIC is a suspected aldol-condensationproduct B
Target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low.
C.
Analyte has been confirmed by GC/MS analysis UD R.esults. are'reported: from a diluted aliquotof the sample B
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or~more R
Sample results are rejected
.U Analyte wasartalyzed for, but not:detected above the MDL, MDA, or LOD.
UTI Gamma Spectroscopy-Uncertain identification X
ConsuftCase Narrative, Data Summary package, or Project Manager.concerning this qualifier
- Y QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
38
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address :.
362 Injun.Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy.
Project:
Soils.PO# 002332 Report Date: October 4,2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0001--012F 172114004 TS 12-SEP-06 20-SEP-06 Client 14.7%
Proiect:
Client ID:
Vol. Recv.:
YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date
.Time Batch Nit, Rad Gamma Spec Analysis GamnmaSoiid-FSS GAM &.ALL FSS 226 Ingrowth Waived Actinium-228 0.917.
Arriericium-241.
U
-0.308
- Bismuth-212
.. 0.617 Bismuth-214 0.567 Cesium-134 U
0.0476 Cesium-137 0.085
- Cobalh-60 U
0.00907 Europium-152 U
-0.108 Europium-154 U
-0.0462 Europium-155 U
0.00678 Lead-212 0.841 Lead-214 0.603 Manganese-54 U
0.0123 Niobium-94 U
-0.0179 Potassium-40 13.2 Radium-226 0.567 Silver-108m U
-0.0113 Thall ium-208 0.280
+/-0.182
+/-0.126
-/-0.267
+/-0.117
+/-0.0403
+/-0.0526
+/-0.0268
+/-0.0688
+/-0.0829
+/-0.0727
+1-0.0715
+/-0.0938
+/-0.026
+/-0.0268
+/-1.05
+/-0.117
+/-0.0237
+/-0.0515 0.0648 0.0856 0:151 0.0376 0.0263' 0.0245 0.0227 0.0511 0.0521 0.062 0.0325 0.0388 0.0225 0.0182 0.184 0.0376 0.0186 0.0206
..+-.-0..82
+/-0.126
+/-0.267
+/-0.117
+/-0.0403
- +/-0.0526
+/-0.0268
+!-0.0688
+/-0.0829
+/-0.0727.
+/-m.0715
- +/-0.0938
+/-0.026
+/-0.0268
+/-1.05
+/-0.117
+/-0.0237
+/-0.0515 0.140 0:176 0.322 0.0796 0.0557
.0.0515 0.0495
.0.107 0.116
.0.128
- 0.0672 0.0811 0.0478 0.0387 0.409 0.0796
.0.0391 0.0435 pCi/g6 pCilg_
pCilga Cui/
pCi/g6 pCi/g pCi/g0 pciig-pci/g' pCi/g pCi/g pCi/g-pCi/g1 pCi/g pCi/g-MJH.
10/02/06.0649 574334.
The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXMvl2 09/20/06 1536 570843 The following Analytical Methods were performed Method Description EML HASL 300,4.5.23 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance crileria Result is less than value reported 39
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0001-012F Project:
YANK01204 Sample TD:
172114004.
ClientID:
YANK001 Prme" et U
y
".P *Vol.
Recv.: "
Paamte Qallslierl Result Uncertainty LCS Tru l*,fA Units DFi Analyst Date Time Batch MbJ Result is greater than value reported A:.
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery.islow C
Analyte has been confirmed by GC/fvIS analysis.
D Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds Spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
5Ii Gamma Spectroscopy-Uncertain identification X
Consult Case Narrative, Data Summary package, or Project. Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +!-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
40
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd
Contact:
Project:
East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: October 4, 2006 Client.Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0001-016F 172114005 TS 1.2-SEP-06 20-SEP-06 Client 12.9%
P'oiect:
YANK01204 Client ID:
IYANK001..
Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA.
Units DF Analyst Date Time Batch Mt.
Rad Gamma Spec Analysis.
Gamnia.Solid-FSS GAM & ALL FSS.226 Ibgrowth*
Waived Actinium-7228 0.839
+1-0.188 Americium-241 U
0.0204
+/-0.0268..
Bismuth2) 12
-UI 0.00
+/-0.472 Bismuth-214 0.588
+/-0.106 Cesium-1 34 U
0.0533
+/-0.0306 Cesium-137
.0.0961
+1-0.0563..
0.00495
+/1=O.0235 Eufopium-152 U -0.00205
+/-0.0566 Europium-154 U
-0.0049
+/-0.0823 Europium-155 U
0.0338
+/-0.0444 Lead-212.
0.808
+/-0.0642 Lead-214 0.539
+/-0.0909 Manganese-54 U -0.00139
+/-0.023 Niobium-94 U
-0.0112
+/-0.0237 Potassium-40 11.8
+/-1.02 Radium-226 0.588
+/-0.106 Silver-108m U
0.00216
+/-0.0185 Thallium-208 0.276
+/-0.0541 0.0649 0.0234 0.148 0.0347 0.0266 0.0226 0.0201 0.0466 0.0681 0.0411 0.0262 0.0347 0.0188 0.019 0.184 0.0347 0.0162 0.0174
+1-0. 188
+/-010268
+/-0.472
+/-0.106
+/-0.0306
+/-0.0563:
- +/-0.0235
+/-0.0566 1/-0.0823
+/-0.0444
+/-0.0642
+4-0.0909
+/-0.023
+/-0.0237
+/-1.02
+/-0.106
+/-0.0185
+/-0.0541
- 0.142
-0.0484.
- 0.320 0.0744 0.0566 0.0481 0.0448 0.0983 0.149 0.0854 0.0546 0.0731 0.0407 0.0406 0.414 0.0744 0.0345 0.0375 pCi/g pCi/g-pCi/kg pCi1g pCi/0 pCi/g pCi/i pCi/g-pCi/_g pCi/g' p040g pCi/.g pCi/g-pCi/.g MJ HI 10/02/060650.574334 1
The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09120/06 1536 570843 The following Analytical Methods were performed Method Description EML HASL 300,4.5.2.3 Notes:
The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 41
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd..
East Hampton, Connecticut 06424 Report Date: October 4,2006
.Contact:
Mr..Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0001-016F Proiect:
YANKO 1204 Sample ID:
172114005 ClientID:
YANK01I Vol. Recv':
Parameter Qualifier Result Uncertainty LC TPU MIDA Units DF Analyst Date Time Batch Mt Result is.greaterthan value reported A
The TIC is a suspected aldol--condensation product B
Target analyte was detected in the associated blank
.:BD. Resuls are either below the MDC or tracer recovery. is low C.,.Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted. aliquot of the sample H
Analytical holding time was exceeded I
Value is estimated
.N/A Spikerecovery limits do not apply... Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy-Uncertain identification X
Consult.Case Narrative, Data Summary package, or Project. Manager concerning this qualifier Y
QC Samples were not spiked with this compound RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
42
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis of Analvsis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: October 4. 2006 Client Sample 1ID; Sample ID:
Matrix' Collect Date:
Receive Date:
Collector:
Moisture:
9530-0001-017F 172114006 TS.
12-SEP-06 20-SEP-06 Client 14.2%
Project:..
YANK01204 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units
- DF Analyst Date
- Time Batch Mt Rad Gamma SpecAnalysis
.Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waihed Actinium-228.
0.828
.+/-0.191 Arnericium-241 107 U
.+/-0.0746 Bismuth-212 0.881
+/-0.459 Bismuth-214 0.612
+/-0.130 Cesium-134 U1 0.00
+/-0.0376
" Cesium-137 0.182.
/-0.0483 Cobalt-60 U -0.00988
+/-0.0263 Europium-155.
U 0.0683
--- 0.0624 Europium-154 U
0.104
+/-0.0885 Europium-155 U
0.0308
+/-0.0643 Lead-212 0.882
+/--0.0991
" Lead-214 0.857
+/-0.131 Manganese-54 U 0.000152
+/-0.0265 Niobium-94 U
0.0279
+/-0.0215 Potassium-40 13.3
+/-1.37 Radium-226 0.612
+/-0.130 Silver-108m U -0.00885
+/-0.0202 Thallium-208 0.282
+/-0.0618 0.0683 0=0601 0.126 0.0327 0.028
. 0.02 1 0.0211 0.055 0.0671 0.0522 0.0264.
0.0339 0.022 0.0199 0.229 0.0327 0.0156 0.022
+1-0.191
+/-0.0746.
.+/-0.459
+/-0.130
+/-0.0376
+1/-0.0483.
+1-0.0263
.+/-0.0624
+/-0.0885
+/-0.0643
+/-0.0991
+/-0.131
+/-0.0265
+/-0.0215
+/-1.37
+/-0.130
+/-0.0202
+Y-0.0618 0.149
" 0.125 0.276 0.0707 0.0597 0.045.!
0.0471 0.116 0.148 0.109 0.0555 0.0721 0.0474 0.0426 0.507 0.0707 0.0335 0.0469 PCi/.g pCi/g-pCi/g0 pCi/g pCi'g-pKilg-pCi/.g PC~i/g!
PCii/.
pCi/g1 pCi/g1
- pCilg, pci/go PCi/g0 MJHI 10/02/060650 574334..
The follovwing Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021
.LXM2 09120/06 1536 570843 The following Analytical Methods were performed Method Description I
EML HASL 300,4.5.2.3 Notes:
The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 43
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4, 2006
Contact:
Mr. Jack.McCarthy Project:
Soils PO# 002332 Client SampleID:
9530-0001-017F Project:
YANKOJ204 Sample ID:..
172.114006 Client.ID.:
YANKOOI VoL Recv.:
Parameter Qualilier Resuli Uncertainty 1LC TPU INEDA Units DF Analyst Date Time Batch Mt
>. Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte Was detected in the associated blank D
Results are. either below the MDC of tr-acer recovery is low
.. C.Analyte has been confirmed by GC/MSanalysis I:.
D Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated NIA Spike recovery limits do not.apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UT Gamma Spectroscopy-Uncertain identification X
Consult Case Narrative,.Data. Summary package, or Project Manager concerning this qualifier Y.
- QC Samples were notspiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
44
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company.:. Connecticut Yankee Atomic Power
- Address:
362 Injun HollowRd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date:
October 4, 2006 Client Sample ID:
Sample ID:
Matrix:.
Collect Date:
Receive Date:
Collector:
Moisture:
Parameter.
Qualifier Result Ur Rad Gamma Spec Analysis Gatnna, Sold-FSS GAM & ALL FSS 226 Ingrowt/i Wa~ied Actinium-228.
- 0.945 Americium-241 U
0.0923 Bismuth"212 0.675 Bismuth-214 0.732 Cesium-134 U
0.0349 Cesium-137 0.167
+
Cobalt-60 "U -0.00764.
Europium-152 U
-0.0133 Europium-1 54 U -0.00119 Europium-155 U.
0.063.
+
Lead-2 12 0.991 Lead-214 0.806 Manganese-54 I
U
-0.0134
+
Niobium-94 U
-0.0159 Potassium-40 13.2 Radium-226 0.732 Silver-108m U
0.0122
+
- Thallium-208 0.272 9530-0001-018F 172114007 TS 08-SEP-06 20-SEP-06 Client 14.8%
Proiect:
YANK01.204 Client ID:
YANKO
.I Vol. Recv.!
icertainty
'LC TPU MlDA Units DF Analyst Date Time Batch Mit
+/-0.238
+/-0.096
+/-0.431
+1-0.138 41-0.0373
-,"0.0399
-/-0.0307.
/-0.0753
-/-0.0954
/-0.0773
+/-0.113
+/-0.124
/1-0.0253 1/-0.0516
+/-1.34
+/-0.138
/-0.0263
+/-0.0551 0.0832 0.0737.
0.165 0.0413 0.0288 0.0254 0.0244 0.0589 0.0784 0.0658 0.0356
- 0.042 0.0203 0.0222 0.214 0.0413 0.0225 0.023
+1-0.238
+.1/-0.096
+/-J0.43 1
+/-0.138
+/-0.0373
+1-0.0399
+/-0.0307
+/-00753
+/-0.0954
+/-0.0773
+/-0.113
+/-0.124
+/-0.0253
+/-0.0516
+/-1.34
+/-0.138
+/-0.0263
+/-0.0551
.0.166.
0.147..
0.330 0.0825 0.0575 0.0507
- 0.0488-0.118 0.157 0.132 0.0712 0.084 0.0405 0.0443 0.428 0.0825 0.045 0.046
- PP./g pCi/i pCi/.0 pCi/g.
pCi/g-pci/g.
pCi/g2 pci/g.
pCil/2 pCi/g0 pCi/g-pCilg' pCi/g.
pci/g.
MJH1 10/02/06 065.9:574334 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A--021 LXM2 09/20/06 1536 570843 The following Analytical Methods were performed Method.
Description I
EML HASL 300,4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 45
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:. Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0001-018F Proiect:.
YANKO 1204 Sample ID:
172114007
.... Client ID:.
YANK001 Vol. Recv.:
Parameter Qualificr Result Unicuriainty LC TPU NIDA Units DF Analyst Date Time Batch Mvlt Result is greater than value reported A.
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results ate either below the MIDC or tracer recoverv is low
- C Analyte has been confirmied by GUMS analysisi D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, orLOD.
UI Gamma Spectroscopy-Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier
.Y QC Samples were not spiked with this compound.
A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
46
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:ý Soils PO# 002332 Report Date: October4,2006 Client Sample ID:
Sample ID:
Matrix:.
Collect Date:
Receive Date:
Collector; Moisture:
9530-0001-OOIF 172114008 TS 08-SEP--06 20-SEP-06 Client 12.9%
Proiect:
YANKO 1204.
ClientlD:
YANKOO0 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU NI.DA Units DF Analyst Date Time Batch Mt Rad Gamma Spec Analysis Gamnna Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.738
.+/-0.227 0.0713
+/-0.227 0.143 pCilg i.MHJ 10/02/06 0700 574334
.Ameficium-241 U
-.0.015
+/-0.104 0.0784
+/-0.104 0.157.
pCig Bismith-212 0.645
+/-0.283 0.170
+/-0.283 0.340 pCi/g BismuIth-214 0.502
+/-0.108 0.0376
+/-0.108 0.0751 pCi/g Cesium-134 U
0.0168
+/-0.0257 0.0246 +1--0.0257 0.0492 pCi/g Cesium-137
.0.130
+1-0.0406 0.0215 +/-0.0406 0.0429 pCilg Cobalt-60 U
0.0131
+/-0.025 0.0215.+/-0.025 0.0429 pCi/ga
.Europiurn-152 U
0.0626
+/-0.0822 0.0536 +/-0.0822 0.107 pCi/g Europium-1 54 U
0.0345
+/-0.0817 0.0713 +/-0.0817 0.143 pCi/g Europium-155 U
0.0739
+/-0.0872 0.0598 +/-0.0872 0.120 pCi/g.
Lead212..
1 0;685
+/-0.0908 0.0323 +/-0.0908
. 0.0646 pCi/g Lead-214 0.624
+/-0.109 0.0365
+/-0.109 0.0729 pCi/g Manganese-54 U
0.00591
+/-0.0242 0.0212 +/-0.0242 0.0423 pCi/g Niobium-94 U 0.000794
+/-0.0233 0.0194 +/-0.0233 0.0388 pCi/g Potassium-40 11.8
+/-1.22 0.190
+/-1.22 0.379 pCi/g Radium-226 0.502
+/-0.108 0.0376
+/-0.108 0.0751 pCi/g Silver-108m U
0.0163
+/-0.022 0.0196
+/-0.022 0.0392 pCi/g Thallium-208 0.217
+/-0.0523 0.0203 +/-0.0523 0.0407 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09/20/06 1536 570843 The following Analytical Methods were performed Method Description.
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 47
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:. Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4. 2006
Contact:
Mr. Jack McCarthy
- Project:
Soils PO# 002332 Client Sample ID:
9530-3001-001F Projec.
YANK01204 SamplelD:.-
172114008 Client LD:
YANK001" Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Resultis greater.than value reported A
The TIC is a suspected aidol-condensation product B
Target analyte was detected in the associated blank 13BD-Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by.GCIMS analysis.
D Resultsare reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated.
N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy-Uncertain identification X
Consult.CaseNarrative, Data Summary package, or Project Manager concerning this qualifier Y
QC. Samples were not spiked with this compound" A
RPD of sample and duplicate evaluated using +/-RI. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
48
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee. Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils P0# 002332 Report Date: October 4, 2006 Client Sample ID:
Sample ID:
Matrix:
CollectDate:
Receive Date:
Collector:
Moisture:
9530-0001-002F 172114009, TS 08-SEP-06 20-SE--06 Client 8.53%
Proiect:
YANKO 1204 Client ID:
YANK001 Vol. Recv.:
l'arameter Qualifier Result
'Uncertainty LC TPU llDA Units DF Analyst Date Time Batch MN Rad Gamma SpecAnalysis.-
Gamma Solid-FSS GAM.& ALL FSS 226 Ingrowtih Waived Actiniurn-228.
0.696
+/-4.268 0.114 +/-0.268 0.227.
pCi/g MJHIt f 10/02/06 0812 574334.
Americirium-241 U -0.00484
+1-0.0496 0.0407 +/-0.0496 0.0813 pCi/g Bismuth212.
0.561.
."--0.4449 0.204
+/-0.449 0.407 pCi/g Bismuth-214 0.653
+/-0.137 0.0605
+1-0.137 0.121 pCi/g Cesium-134 U
0.00964
+/-0.0411 0.0364 +/-0.0411 0.0727 pCi/g.
Cesium-137 0.127.
.. +/-0.0449..
0,0255 +/-0.0449 0.0509.
pCi/g.
U
-0.0357
...+/-0:0455 0.0329.j-/-0.0455.
0.0658 pCi/g.
Europium-152 U -0.0113.
+/-0.0985.
0.069 +/-0.0985 0.*138 pCi/g Europium-154 U
0.0778
+/-0.218 0.112
+/-0218 0.225 pCi/g Europium-155 U
0.0536.
+/-0.0919 0.0584 +1-0.0919 0.117 pCi/g Lead-2.12 0.696
+1-0.0999 0.0395 +1-0.099.9
.0.0789 pCilg Lead-214
.0.578
+/-0.122 0.0501
+/-0.122 0.100 pCiug Manganese-54 U
-0.0312
+/-0.0368 0.0284 +/-0.0368 0-0567 pCi/g Niobium-94 U
-0.0259
+/-0.0337 0.0271 +/-0.0337 0.0541 pCi/g Potassium-40 9.66
+/-1.29 0.190
+/-1.29 0.380 pCi/g Radium-226 0.653
+/-0.137 0.0605
+/-0.137 0.121 pCi/g Silver-108m U
0.02_83
+/-0.0287 0.0266 +1-0.0287 0.0531 pCi/g Thallium-208 0.277
+/-0.0706 0.0276 +/-0.0706 0.0552 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09/20/06 1536 570843 The folloing Analytical Methods were performed
- Method
..... Descriition.
EML HASL 300,4-5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 49
GENERAL ENGINEERING LABORATORIES., LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:
October 4, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530--0001-002F Project:
YANK01204 Sample ID:,.
172114009 Client D:
YANK00...
Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Result is greater than value reported A. The TIC is a suspected aldol-condensation product' B
Target analyte was detected in the associated blank BD Results are either below the. MDC or tracer recovery is low.
C Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of ihe sample H
Analytical holding time was exceeded J
Value is estimated
.N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sanmple results are rejected U
Analyte was analyzed for,.but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy-Uncertain identification X.
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples.were not spiked with this compound A RPD ofsample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
50
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - ww*w.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power
.Address 362. Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332.
Report Date: October 4, 2006 Client.Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector Moisture:
9530-0001--003F 1721140M0 TS 08-SEP-06 20-SEP-06 Client 14_3%
Proiect:
Client 1D:.
Vol. Recv.:
YANKO 1204 YANK0oI Parameter Qualifier Result Uncertainty LC.
TPU MDA Units DF Analyst. Date Time Batch Mt, Rad Alpha Spec Analysis Alphaspec.Am241, Cm, SolidALL FSS Americium-241 U
Ctirium-242 U
Curium-243/244 "
U 0:0467
.0.00
-0.0131
+1/0. 0757
+A-0.0582
+/-m0.0564:
0.0244 0.00 0.0346
+4-0.0759
+/-0.0582
+/10.0564 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U
-0.11 Plutonium-239/240 U
0.0343 Liquid Scint P1241, Solid-ALL FSS Plutonium-241 U
0.294 Rad Gamma Spec Analysis Gaonina, Solid-ESS GAM & ALL FSS 226 lngrowth Waived Actinium-228 0.714 Americium-241 U -0.0786 Bismuth-212 0.614 BismuIth-2 14 0.576 Cesium-134 U
0.0352 Cesium-137 0.259 Cobalt-60 U-0.000206 Europium-152 U
-0.021 Europium-154 U
0.00953 Europium-155 U
0.0328 Lead-212 0.849 Lead-214 0.582 Mlanganese-54 U
0.00343 Niobium-94 U
0.012 Potassium-40 12.6 Radium-226
-0.576 Silver-108m U
0-00762 Thallium-208 0.275 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U 0.00833
+
Rad Liquid Scintillation Analysis
+/-0.141 0.148
+/-0.141
+/-0.0774 0.0416 +/-0.0775
+/-9.99
.8.37
+/-9.99
+/-0.158.
+/-0. 119
+/-0.320
+/-0.109
+/-0.025 I
+/-0.0505
+/-0.0228
+1-0.0606
+/-0.0662
+1-0.0592
+/-0.0694
+/-0.102
+/-0.0221
+/-0.0206
+/-0.952
+/-0:109
+/-0.0187
+/-0.0532 0.0691 0.0887 0.151 0.0354 0.0238 0.0182 0.0191 0.0493 0.0569 0.055 0.0292 0.0344 0.0186 0.0183 0.143 0.0354 0.017 0.0172
- .,42.158
+/-0.119
+/-0.320
+/-0.109
+2-0.0-251
+1-0.0505
+1-0.02-28
+/-0.0606
+/-0.0662
+/-0.0592
+/-0.0694
+/-0.102
+/-0.02_2
+"-0.0206 44-0.952
-+1-0.109
+/-0.0187
+4-0.0532 0.123
- 0.0804 0.143, 0.369 0.156 17.6 0.150 0.185 0.325 0.0757 0.0511 0.0392 0.0429 0.104 0.126 0.114
...0:061' 0.0727 0.0404 0.0391 0.334 0.0757 0.0361 0.0371 0.0129 pCi/g pC~ilg pcilga pCilg pCi/g pCi/ga pCi/g.
pCilg pCilg pci/ga pCi/9 pC./g pCi/a PCi/g pCiig1 pCi/g9 pCiig1 pCLg pci/g' pCil~g TC I.
09/29/06 2214 572122. 2 MJHI 10/02/06 0918 574334 4
KSDI 09/29/06 2335 571177 5
DFAI 09/25/06 0226 570933 C
TCI 09/28/06 11.56 572120 I
TCI 09/28W06 0935 572121 I
LSC, Triti ni Dist, Solid-HTD2.ALL FSS Tritium U
-1.52
/-0.00781 0.00603 +1-0.00781
+/-6.64 5.67
+1-6.64 12.1 pcig 51
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: October 4, 2006 Client Sample ID:
Sample ID:
9530-0001--003F 172114010 Proiect:
YANK01204 Client ID-YANK001 Vol. Recv.:
Parameter UQaWfer Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch M1 Rad Liquid Scintillation Analysis Liquid Scint C14, Solid All, FSS Carbon U
0.00
+/-0.0813
.-0.0682 4/-0.0813 0.145 pCi/g AXD2 09/23/06 1509 570934 Liquid Scint Fe55, Solid-ALL FSS fron-55 U
.12.2
+/-25.2 17.2
+/-25.2 36.0 pCi/g MXPI 09/27/06 1330 570929 Liquid ScintNi63. Solid-ALL FSS Nickel-63 U
-5.95
+/-10.8
" 9.34
.+/-10.8
.19.6 pCilg "
XPI 09/25/06 1634 570930..
Liquid Scihir Tc99, Solid-ALL FSS Technetium-99 U -0.0782
+1-0.274.
0.232
+/-0.274 0.478 pCi/g "KXR I 09/29/06 1634 570932 1 The, following Prep Methods were performed 1MIethod Description..
Analyst Date Time Prep Batch*
Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09120/06 1536 570843 The followingAnalytical Methods ver-e performed Method Description I
DOE EML HASL-300, Am-05-RC Modified 2
DOE EML HASL-300, Pu-I l-RC Modified 3
DOE EML HASL-300. Pu-I l-RC Modified 4
EML HASL 300,4.52.3 5
EPA 905.0 Modified 6
EPA 906.0 Modified 7
EPA EERF C-0I Modified 8
DOE RESL Fe-I, Modified 9
DOE RESL Ni-I, Modified 10 DOE EML HASL-300, Tc-02-RC Modified I I DOE EML HASL-3(MTc--2-RC Modified Surrogate/Tracer recovery Test Recovery%
Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 96 (15%-125%)
Plutonium-242 Alphaspec Pu, Solid-ALL FSS 87 (15%-125%)
Carrier/Tracer Recovery Liquid Scint Pu24 I, Solid-ALL FE 84 (25%- 125%)
Carrier/Tracer Recovery GFPC, Sr9O, solid-ALL FSS 79 (25%-125%)
Carrier/Tracer Recovery Liquid Scint Fe55, Solid-All, FS 70 (15%-125%)
Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 74 (25%-125%)
52
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4, 2006
Contact:
Mr. Jack McCarthy
.-Project:
Soils PO# 002332 Client Sample ID:
9530-0001-003F Project:
YANKO 1204 Sample.ID:
1721.14010 Client ID; YANKO01.
Vol. Recv..
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch NIt Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 76 (15%-125%).
Notes:
The Qualifiers in this report are defined as follows S A quality control analyte recovery is outside of specified acceptance criteria
<. Result is less than value reported
- 5. Result is greater thanvalue reported
.A. The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MSanalysis D Results are reported from adiluted aliquot of the sample H
. Analytical holding time was exceeded J
Value is estimated
..N/A Spike recovery limits. do not apply. Sample concentration exceeds spike concentration by 4X or more R
- Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, orLOD.
UI Gamma Spectroscopy-Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +I-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
53
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address.:
362 Inju.n Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy.
.Project:
Soils PO# 002332 Report Date: October 4,2006 Client Sample ID:
9530-0001-004F Proiect:
YANK01204 Sample ID:
.172114011 ClientID:.
YANK001 Matrix:
TS Vol. Recv.:
Collect Date:
08-SEP-06 Receive Dare:
20-SEP-06 Collector:
Client Moisture:.
15.5%
Parameter Qualifier Result Uncertainty.
LC TPU MDA Units DF Analyst Date Time Batch.NMt.
Gaimta Solid-FSS GAM & ALL FSS 226 lIgrowth Waived
.Actinium-228.
1.02.
".Amcriciumm241.
U 0.000195 Bismuth-2 2 0.578 Bismuth-214 0.622 Cesium-134 U.
0.0251
.+
Cesium-137 0.131 Cobalt-60.
U.
0.0147
-+
Europium-152 U
-0.0169
+
Europium-154..
U.0.00939 4
" Europium-15-5 U
0.0221
-+
Lcad-212 0.985
+
Lead-214 0.689 Manganese-54 U
0.0214
+
Niobium-94 U -0.00774 Potassium-40 14.8 Radium-226 0.622 Silver-108m U
-0.0104 Thallium-208 0.264
+1-0.178
/--0.036
+/-0.394
+/-0.121
-/-0:0353 0.0653 1f-0.0291
-/-0.0581
-I-0.0825 0.0577
/--0.0757
+1-0.108
-/-0.0294
/-0.0236
+/-1.12
+/-0.121
+/-0.0227
/-0.0635 0.0716 0.0292 0.171 0.0425 0.0279 0.0215 0.026 0.0504 0.0707 0.0515 0.0308 0.0375 0.0259 0.0193 0.186 0.0425 0.0191 0.0208
- +/-0.178
+/-0.036
+/-0.394
+/-0.121
+/--m0.0353
+/-0:0653
+/-0.0291
+/-0.0581
.+/-0.0825
+/-0.0577
+/-0.0757
+/-0.108
+/-0.0294
+1-0.0236
+/-1.12
+/-0.121
+/-0.0227
+/-0.0635 0.156 0.0602 0.366 0.0903 0.0596 0.0462 0.057 0.106 0.155 0.107 0.0642 0.079 0.0553 0.0414 0.421 0.0903 0.0405 0.0446 pCi/1!
pCi/g" pCi/.g pCi/g0 pC4/g pCi/g0 pCi/g, pCi/ag pCi/g pCilg-pCilg.
PC if pCi/g pCi/g pCi/.g pCi/g pCi/g-MJHI 10/02/06 09i9 574334 1
The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD--A-021 LXM12 09/20/06 1536 570843 The following Analytical Methods wert performed M ethod Description EML HASL 300,4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is lessthan value reported 54
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -. (843) 556-8171 - www.gel.com Certificate of Analysis Company:.Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4, 2006
- Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
.9530--001-004F Project:
YANKO 1204 Sample ID:.
172114011.
Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDIA Units DF Analyst Date Time Batch Mt Result is greater than value reported A
The TIC is a suspected aldot-condensation produict B
Target analyte was detected in the associated blank-
-BD Results are either below the MDC or tracer recoveryis low C
Analyte has bein confirmed by GC/MS analysis.,
D Results are reported from a diluted aliquot of'the sample H
Analytical holding time was exceeded J
Value is estimated NIA Spike recoverylimits donot apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, butnot detected above the MDL, MDA, orLOD.
UI Gamma Spectroscopy-Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were notspiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
55
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis
.Company:
Connecticut Yankee Atomic Power.
Address :
362 Injun Hollow Rd
Contact:
'.Project:
East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332:
Report Date: October 4, 2006 Client Sample ID:
Sample lD:......
Matrix:
Collect Date:i Receive Dale:
Collector 9530-0001 -O05F 172114012 TS.
.08-SEP-06 20-SEP-06 Client I - o-Of Proiect:
YANKO 1204 Client l)D:
YANK001
.Vol. Recv:
Parameter Qualifier Result Uncertainty LC TPU MIDA Units DF Analyst Date Time Batch M1 Rad Gamma Spec Analysis Gamia, Solid FSS GAM &.ALL FSS 226 hJgrowvrh Waived Actinium-228
.0.486
+/-0.139 0.0523
+1-0.139
- 0. 114
- pCi/g..
MJHI 10/02/06 0919 574334 Americium-24 I U...-0.0773
+/-0.0839 0.0672 +/-0.0839
'0.139' pCi/g..
Bismuth212 0.380
+/40.185
'0.125
+/-0.185 0.268 pCilg Bismuth-214 0.475
+/-0.0791
- 0.0275 +/-0.0791 0.0589 pCi/g Cesium-134 Ui 0.00
+/-0.0296 0.021 +/-0.0296 0.0446 pCi/g Cesium-137 0.0485
+/-0.024 0.0172
+/-0.024 0.0367 pCi/g Cobalt-60 U
- --Q00 I.
+/-0-.0185.
0.0154 +/-0.0185 0.0343 pCi/g Europium-152 U
--0.0439
- +-/0.0462 0.039 +/-0.0462 0.0824 pClg" Europium-154 U
0.00551
+1-0.0535 0.0457 +/-0.0535 0.101 pCi/g.
Europium-155 U
0.0377
+/-0.0494 0.0463. +/-0.0494 0.096 pCfi/g Lead-212 0.626
+1-0.0591.
0.023 -4/-0.0591 0.0481.
pCi/g Lead-2 14 0.A62
+/-0.0792.
0.0295 +/-0.0792 0.0622 pCi/g Manganese-54 U -0.00439
+/-0.0218 0.0163 +/-0.0218 0.035 pCilg Niobium-94 U -0.00642
+/-0.0165 0.0134 +/-0.0165 0.0289 pCi/g Potassium-40 1 1.2
+/-0.824 0.153
+/-0.824 0.341 pCi/g Radium-226 0.475
+/-0.0791 0.0275 +/-0.0791 0.0589 pCi/g Silver-108m U -0.00535
+/-0.0152 0.013 +/-0.0152 0.0278 pCilg Thallium-208 0.225
+/-0.042 0.0121
+/-0.042 0.0262 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09/20/06 1536
.570843 The following Analytical Methods wetem Irformed Method
-Description.
I EML HASL 300, 4.523 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is otitside of specified acceptance criteria Result is less than value reported 56
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-81.71 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4, 2006
Contact:
Mr. Jack McCarthy Project:
Soils.PO# 002332.
Client Sample ID:
9530-0001-005F Project:
YANK01204 Sample.lD:
.172114012 Client.lD:
YANK001 Vol. Recv.:
rarameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Nit, Result is greater than value reported A : The TIC is a suspected aldol-condensation product.
B Target analyte was detected in the associated blank 1BD Resltis are eithera below the MDC or tracer recovery is low C.
Analyte has been confirmed by: GC/MS analysis' D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration. exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy-Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y. QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
57
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 556-8171'- www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332
.Report Date: October 4, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0001 -006F 172114013 TS 08-SEP-06 20-SEP-06 Client 11.7%
Project:.
YANK01204 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier. Result Uncertainty
'LC TPU.
MDA Units DF Analyst Date Time Batch Mi Rad Gamma Spec Analysis Gannna,Solid--FSS GAMI & ALL FSS 226 Ingrowth Waived Actinium-22
.0.680
+/-0.162
.0.0598
+0-0.162 0.129.
pCi/g MJHI 10/02/06 0920 574334 Americium-241 U
0.014.
+/-0.0793 0.0622 +1-0.0793 0.128 pCi/
Bismuth-212 0.558
+/-0.261
.0139
+/-0.261 0.298 pCi/g Bisrnuth-214 0.573
+/-0.0981 0.0327 +/-0.0981 0.0696 pCi/g Cesium-134 UI 0.00
+/-0.0311 0.0234 +/-0.0311 0.0496 pCilg Cesium-137 0.121
+/--0.0276 0.0199: +/-0.0276 0.0423:
pCig" Cobalt-60 U
0.00766
+/-0;0243 0.0.187+t-0.6243.
0.0413 pCi/g Europium-152 U
0.0263
+/-0.0669 0.0524.+/-0.0669 0.109 pCi/g Europium-154 U -0.00581 41-0.0716 0.0516 +/-0.0716 0.114 pCi/g Europium-155 U 0.00914
+/-0.0614 0.0537 +/-0.0614.
0.1.11
. pCi/g
.Lead-212 0.803
+1-0.0853 0.0278 +/-0.0853
.0.057.
pCilg
- Lead-214 0.584
+1-0.120 0.0342. +/-0.120 0.0718 pCi/g Manganese-54 Ut 0.00
+/--0.0294 0.0184 +/-0.0294 0.0394 pCilg Niobium-94 U -0.0003
+/-0.0202 0.017 +/-0.0202 0.0362 pCi/g Potassium-40 12.7
+/-1.14 0.118
+/-1.14 0.275 pCi/g Radium-226 0.573
+/-0.0981 0.0327 +/-0.0981 0.0696 pCilg Silver-108m U -0.00575
+/-0.0199 0.0169 +/-0.0199 0.0357 pCi/g Thallium-208 0.215
+/-0.0463 0.0168 +/-0.0463 0.0358 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 091220/06 1536 570843 The following Analytical Methods were performed Methlud Desciipti.n EML HASL 300,4.5.2.3 Notes:
The Qualifiers in thisreport are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 58
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address.:
362 Injun.Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4. 2006.
Contact:
Mr. Jack McCarthy
' Project:
Soils PO# 002332 Client Sample ID:
9530-0001-006F Project:
YANK01204 Sample ID:
172114013...
Client ID:
YANK001" Vol. Recv.:.
Parameter Qualifiler Result Uncertainty LC TPU iVHDA Units DF Analyst Date Time Batch Mt Result is greater than value. reported.
A The TICis a suspected aldol-condensation product B.Target analyte was. detected in the associated blank
.BD Results are either below the MDC or tracer.recovery is low C.
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample:
H Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits donot apply. Sample concentration exceeds spike concentration by 4X or more
.R" Sample results are rejected.
U Analyte Was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy-Uncertain identification X. Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
59
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton. Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332.
Report Date: October 4, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0001-006FS 117211.4014.
TS.
08-SEP-06 20-SEP-06 Client 11.7%
Project:
YANK01204 Client ID; YANKOOI Vol. Recv.:
Parameter Qualifier Result* Uncertainty LC TPU IlDA Units DF Analyst Date.
Time Batch Mt Rad Gamma Spec Analysis Ga,,,ia,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium -228 Americium-24l Bismuth --w?-
12 B ismuth-14 Cesium-134 Cesium-137
.Cobalt 60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214' Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.926 U
-0.0132 0.646
.0.585 U
0.0555
- .0.124 U
0.0178 U -0.00696 U
-0.0305 U
0.0424 0.684 0.642 U
0.0102 U
0.0207 12.7 0.585 U-0.000565 0.241
+/-0.246
+/-.0.03.96 S.+/-0.345
+/-0.128
+/-0.0388
+/-0.0454
+/-0.0345
+1-0.076
+/-0.0976
+/-0.0757
+/-0.0847
+/-0.132
+/-0.0367
+/-0.0303
+/-1.11
+/-0.128
+/-0-026
+/-0.0641 0.104 0.0331 0.1.96 0.052 0.0355 0.0307 0.0302.
0.0627 0.0786 0.0551 0.0486 0.0463 0.0272 0.0265 0.250 0.052 0.0227 0.0271
- +/-0.246
+1/-0.0396
+/-0.345
+/-0.128
+/-0.0388
+/-0.0454
+/-0.0345
+/-0.076
+/-0.0976
+1-0.0757
+/:0.0847
+1-0.132
+/-0.0367
+/-0.0303
+/-I.11
+/-0.128
+1-0.02_6
+/-0.0641
.. 0221.
..0.0683 0.418 0.110 0.0749
.0.0647 0.0655.
0.131 0.171 0.114 0.100 0.097 0.0581 0.056 0.551 0.110 0.0477 0.0573.
pCi/0g pCi/0g pCV.g pCif.g pCi/00
- pCilg, pCi/g pCi/g pCiN pCilg pCi/_
pCi/g0 pCi/g pCi/g-pCd/g MJHI 10102/06 0920.0574334 The following Prep Methods were perrormed Method
- Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09/220/06 1536 570843 The following Analytical Methods were performed Method
........ Description I
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
- ý A quality control analvle recovery is outside of specified acceptance criteria Result is less than value reported 60
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power.
Address :
362.njun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-000I--06FS Project:
YANK01204 Sample ID:
172114014.
ClientID:.
YANK001 Vol. Recv.:
Parametcr Qualifier Result Uncertainty LC TPU ivrvA Units DF Analyst Date Time Batch Nit, Result is greater than value reported.
A.- The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank'.
BD ResuIts are either below the MDC or tracer recovery is low C.
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U.
Analyte was analyzed for, but not detected abovethe MDL, NMA, or LOD.
UI Gamma Spectroscopy-Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y.
QC Sampleswere not spiked with this compound A
RPD ofsample and duplicate evaluated using +/-RL Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
61
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www:gel.com (CPrtfi-gft nf Ann]v ck
.L Company:
Connecticut YankeeAtomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002-332 Report Date: October 4. 2006 Client Sample ID:
Sample ID:
Matrix:
Collect.Date:
Receive Date:
Collector:
Moisture:
9530-0001-007F
.172114015 TS 08-SEP-06 20-SEP-06 Client.
14.1%
Proiect:
YANK0 1204 Client ID' YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF. Analyst Date Time Batch Mt Rad Gamma Spec Analysis GanmaSolid-FSS GAM &ALL FSS 226 Ingrowth Waived Actinium-2"28 0.645
+/-0.261 Americium=241 U
- 0.0595
+/-0.0378 BismLtth-212
'.0.977
+/-0.392.
Bismuth-2t4 0.605
+/-0.123 Cesium-134 Ul 0.00
+.-0.046 Cesium-137.
0.134
+/-0.0553 Cobalt-60 U
- 0.0203
+/-0.0343 Europium-I52 U
-0.0415
+/-70.0688 Europium-154 U
-0.0289
+/-0.104 Europium-155 U
.0.0877
+/-0.0987 Lead-212
. 0.881
+1-0.0767 Lead-214 0.585
+/-0.111 Manganese-54 U
0.0176
+/-0.0315 Niobium-94 U
-0.015
+/-0.0302 Potassium-40 13.4
+/-1.18 Radium-226 0.605
+/-0.123 Silver-108m U
0.00285
+/-0.0254 Thallium-208 0.274
+1-0.051 0.0854 0.0357
- 0.207 0.0471 0.0365 0.0297 0.0308.
0.0578 0.0839 0.0524 0.03. 8 0.0434 0.0274 0.024 0.185 0.0471 0.022 I 0.024
- +/-0.261
+/-0.0378
+1-mw&3392
+1-0.123
+/-0.046
+/-0.0553
+/-0.0343.
+/-0.0688
+/-0.104
+/-0.0987
+/-0.0767.
+/-0111
+/-0.0315
+/-0.0302
+/-1.18
+/-0.123
+/-0.0254
+/-0.051 0.187
' 0.0737 0.446 0.101 0.0777 0.0634
- .0.068 0.123 0.185
.0.109 0.0668 0.0917 0.0592 0.0515 0.434 0.101 0.0469 0.0517 pCi/ga pCi/g pCilg PCi/g pCVg.
pCi/g0 pCi/g pCi/g1 pCi/g pCi/g" pCilg pCi/g pCi/.g MJHI. :10/02/06 0921 574334 I
The following Prep Methods were perfoamed Miethod Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-02I LXM2.
09/20/06 1536 570843 The following Analytical Methods werrtprformed
'Method Description EML HASL 300,4.5-23 Notes:
The Qualifiers in this report are defi-ed as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 62
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-0001-007F Proiect:
YANK01204 Sample ID:
17211401.5 Client ID:
YANK001 Vol. Recv.:
Parameter Quauer Result Uncertainty LC TPU fvflIA Units DF Analyst Date Time Batch Mt, Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank-
- BD Results are either below the MvIDC or tracer recoyery is. low.
C Analyte has been confirmed by GCUMS analysis.
D Results are reported from a diluted aliquot of the. sample H
Analytical holding time was exceeded J
Value is estimated N/A. Spike recovery limits do not apply. Sample concent-ation exceeds spike concentration by"4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy-Uncertain identification X
Consult Case Narrative, Data Summary. package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL Ii Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
63
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certifivate of Ana1v.-id I
Company
.Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd
Contact:
Project:..
East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils POO 002332 Report Date: October 4, 2006 Client Sample lD:
Sample ID:.
Matrix:.
Collect Date:
Receive Date:
Collector Moisture:
9530-0001 -009F 172114016 TS.
08-SEP--06 20-SEP-06 Client 12.8%
Project:
YANK01204 Client ID:
YANK001 Vol. Recv.:
- Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Rad Gamma Spcc Analysis Gamnna,Solid-FSS GAM & ALL.FSS 226 Ingrowth Waived Actinitim-228.
0.853
+/-0.145 Americium-241 U
0.0188
+1-0.113 Bismuth-212 0.391 4/-0.278 Bismuth-214 0.511
+/-0.0924 Cesium-134 U
0.0232
+/-0.0242 Cesium-137 0.0641
+1-0.0413 Cobalt-60 U 0.00129
+1-0.0198 Europium-152.
U 0.0365
+/-0.0526 Europium-154 U -0.00251
+/-0.0619 Europium-155.
U 0.0286
+/-0.0599 Lead-212
.0.667
+/-0.0687 Lead-2l 4 0.626
+/-0.0869 Manganese-54 U
0.0317
+/-0.0253 Niobium-94 U -0.0013
+/-0.0177 Potassium-40 13.0
+/-0.831 Radium-226 0.511
+/-0.0924 Silver-108m U
0.0146
+/-0.0167 Thallium-208 0.217
+/-0.0483 0.0559 0.0925.
0.121 0.0314 0.0185 0.0188 0.0169 0.0423 0.0452 0.0534.
0.0337 0.0313 0.0153 0.0152 0.143 0.0314 0.015 0.0146
- +/--0..145
+/-0.113
+/-0.278
+/-0.0924
+/-0.0242
+/-0.0413
+/-0.0198
+/-0.0526
+/-0.0619
+/-0.0599
+/-0.0687
+/-0.0869
+/-0.0253
+/-0.0177
+/-0.831
+/-0.0924
+/-0.0167
+/-0.0483 0.120.
.0.192 0.257 0.0663 0.0394 0.0395 0.0368 0.0888 0.0987 0.111 0.0695 0.0656 0.0328 0.0321 0.315 0.0663 0.0315 0.0311 pqi/g pCi/g" pCi/g pCi/g.
pCilg pCi/g pCilg:
pCil/g pCi/g pCi/g pCilg pCilg pCil.g pCi/g pCi/g pCi/g pCi/g p~i/g MJHI 10/02/06092.1,57.4334.1 The following Prep Methods -were perfonned Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09r.0/06 1536 570843 The follo ieing Analytical Methods wert performed Niethod Description EMIL H-ASL 300,4.5.2-3 Notes:
The Qualifiers in this report are defined as follows:
A qtality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 64
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843).556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4, 2006
Contact:
Mr. Jack McCarthy'
.Project:
Soils PO# 002332.
Client Sample ID:
9530-000li-009F Proiect:
YANK01204 Sample ID:
.172114016 ClientlD:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MNDA Units DF Analyst Date Time Batch NIt Result i.s greater than value reported A
The TIC is a suspected.aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the TvIDC or tracer recovery is low C.
Analyte has been confirmed by GC/IMS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample restlts are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy-Uncertain identification X
Consult CaseNarrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
65
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton. Connecticut 06424 Contact.
Mr. lack McCarthy Project:
Soils PO# 002332 Report Date: October 4, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect*Date:.
Receive Date:
Collector:
Moisture:
- 9530-0001-013F 172114017 TS 08-SEP-06 20-SEP-06 Client 16.6%
Project:
Client ID:
Vol. Recv.:
YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived.
Actinium-228 0.740"
+/-0.127 0.0409
+/-0.127 0.0882 pCilg MJHI 1 10/02/06 0922 574334. 1 Americium-241 U. 0.00362
+/-0.0583 0.05 4+1-0.0583 0.109 pCi/g
" Bismuth-2l2.
0.387
+/-0.189 0.0995
+/-0.189 0212 pCi/g Bismuth-214 0.525
+/-0.0781 0.0268 +/-0.0781 0.0564 pCi/g Cesium-134 U
0.023
+/-0.022 0.017
+/-0.022 0.036 pCi/g
.0.0729
+/-0.0276 0.0153.../-0.0276.
0.0322
.pCi/g
.Cbalt-60 Ul 0.00.
41-0.0373.
0.0138 +1-0.0373 0.0301 pCilg
. Europium-152 U. -0.0476
+/-0.0396 " 0.0323 +/-0.0396 0.0679 pCi/g Europium-154 U 0.000881.
+/-0.0505 0.0419 +/-0.0505 0.0903 pCi/g Europium-1 55-I 0.0.16
+/-005.15 0.0458 +!-0.0515.
0.0945 pCi/g Lead-2 12 0.589
+-0.0732 0.0307 +/-ý.0732-0.0629 pCi/g Lead-214 0.570
+/-0.065 0.027
+/-0.065 0.0564 pCi/g Manganese-54 U
0.0012
+/-0.0157 0.0136 +/-0.0157 0.029 pCi/g Niobium-94 V -0.002299
+/-0.0143 0.0123 +/-0.0143 0.026 pCi/g Potassium-40 12.4
+/-0.724 0.106
+/-0.724 0.235 pCi/g Radium-226 0.525
+/-0.0781 0.0268 +/-0.0781 0.0564 pCi/g Silver-108m U
0.00791
+/-0.0139 0.0123 +/-0.0139 0.0259 pCi/g Thallium-208 0.218
+/-0.0361 0.0143 +/-0.0361 0.0301 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 I_,XIM2 09/20/06 1536 570843 The following Analytical Method were performed Method Description EML HASL 300,4.5.2.3 Notes:
The Qualifiers in this report are defined as follows A quality control analyle recovery is outside of specified acceptance criteria Result is less than value reported 66
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4, 2006
Contact:
Mr. Jack McCarthy
- Project:
SoilsPO#002332 Client Sample ID:
9530-0001-013F" Proiect:
YANK01204 SamplelD:
172114017 ClientID:
YANKO0 I Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank-
- ..BD Results are either below..the &DC or tracer recovery is low C:
Analyte has been confirmed by.GC/MS analysis..
D Results are reported from a diluted aliquot. of the sample H
Analytical holding time was exceeded J
Value is estimated S.N/A Spike recovery limits do not apply..'Saniple. concentration exceeds spike concentration by 4X or more R.. Sample results are:rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy-Uncertain identification
- X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +I-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
67
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut.Yankee AtomicPower Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: October 4.2006 Client Sample ID:1 Sample ID:
Matrix: -
Collect Date:
Receive Date:
Collector:
Moisture:
9530-0001--014F
.172114018 TS..
08-SEP-06 20-SEP-06 Client 13.6%
Protect:
Client ID:
..Vol. Recv.:
YANKO 1204 YANK.001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch MI Rad Gamma Spec Analysis.
Gmnrr,.Solid-FSS GAM & ALL FSS 226 Ingrowth."
Waived Actinium-228 0.770
+/-0.212 0.0859
+/-0.212 0.172 pCi/g MJHI '10/02/06 1023.574334 Americium:-241
- U 0.035
+/-0.04-0 0.0324
+4-0.040 0.0648 pci/.
Bismuth-2 12 0.700.
+/-0.298 0.205
+/-0.298 0.411 pCi/g Bismuth-214 0.596
+/-0.126 0.0446
+/-0.126 0.0892:
pCi/g Cesium-134 U
0.0156
+1-0.0351 0.0314 +1-0.0351 0.0628 pCilg Cesium-137
.0.0547
+1--0.0528
.0.0254 +/-AO.0528 0.0507 pCi/g.
U 0.00268
+/-0.0347 0.0291 +/-0.0347 0.0582 pCi/g Europium-152 U
-0.0696
+/-0.0936 0.0564 4/-0.0936 0.113 pCi/g Europium-154 U
-0.0999
+/-0.101 0.0729
+/-0.101 0.146 pCi/g Europium-155 U
0.00172
+/-0.0565 0.0492 +/-0.0565 0.0982 pCi/g.
Lead-212 0.657 0.086 0.0312
+!/-U0086 0.0623 pCi/g Lead-m214 0.609
"+/-0.10.7 0.0404
+/-:0.107 0.0808 pCi/g" Manganese-54 U
-0.0127
+/-0.0309 0.0214 +/-0.0309 0.0428 pCi/g Niobium-94 U
-0.0162
+/-0.0257 0.0211 +/-0.0257 0.0423 pCi/g Potassium-40 12.5
+/-1.31 0.251
+/-1.31 0.501 pCi/g Radium-226 0.596
+/-0.126 0.0446
+/-0.126 0.0892 pCi/g Silver-108m U
-0.017
+/-0.0234 0.0189 +/-0.0234 0.0378 pCi/g Thallium-208 0.202
+/-0.051 0.0228
+/-0.051 0.0456 pCi/g The following Prep Methods were perrormed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep.GL-RAD-A-021 LXM2
.09/2_0/06 1536 570843 The following Analytical Methodswere performed Mt hod Dcription I
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 68
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Reporn Date: October 4, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332.
Client Sample ID:
9530-0001-014F Project:
YANKO01204 Sample fl):
172.114018 Client ID:
YANKOO I Vol. Recv.:
Parameter Qualirier Result Uncertainty LC TPU NIDA Units DF Analyst Date Time Batch Mt Result is greater than value reported
.A The TIC is a suspected aldol-condensation product B
Target analyte was detected in theassociated blank BD Results are either below the MDC.or tracer recovery is.low..
C
. Analyte has been confirmed by GC/MS analysis D
Results arereported from a diluted aliquot of the sample H
Analytical holding time was exceeded J. Value is estimated N/A Spike recovery limits do not apply, Sample.concentration exceeds spike concentration by 4X or more R
Sample results.are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy-Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked withithis compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
69
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: -Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: October 4, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9530--0001-014FS
- 172_1.14019 TS 08-SEP-06 20-SEP-06 Client 13.5%
Project:
YANK01204 Client ID:
YANKOO0 VoL Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt, Rad Gamma Spec Analysis GamnnaSolid-FSS GAM & ALU FSS 226.ngrowith Waived Actinium-2298 0.724
+/-0.183.
-0.0361
+1-0.0949 Bismuth-212 0.449
+/-0.308 Bismuth-214 0.511
+/-0.103 Cesium-134 UI 0.00
+/-0.0439 Cesium-I137
.0.0729
+/-0.0406 Cobalt-60 U
0.00586
+/-0.0236 Europium-152 U
-0.0409
+/-0.0665 Europium-154 U
-0.0391
+/-0.0666 Europium-155 U
0.0598
+/-0.0586 Lead-212 0.781
+/-0.070 Lead-214 0.632
+/-0.0979 Manganese-54 U
0.00384
+/-0.0213 Niobium-94 U
0.0031
+/-0.0192 Potassium-40 12.2
+/-1.08 Radium-226 0.511
+/-0.103 Silver-10gm U
0.0222
+/-0.0184 Thallium-208 0.294
+/-0.0515 0.0614 0.0756 0.153 0.0328 0.0268 0.0199 0.0208 0.0458 0.0524 0.0541 0.0285 0.0363 0-0182 0.0165 0.139 0.0328 0.0175 0.0166
+/-0.183
+/-0.0949
+/-0.308
+/-0.103
+/-0.0439
+/-0.0406
+/-0.0236
+/-0.0665
+1-0.0666
+/-0.0586
+/-0.070
+/-0.0979
+/-0.0213
+/-0.0192
+/-1.08
+/-0.103
+/-0.0184
+/-0.0515
.0.135
- 0.157 0.330 0.0708 0.0572 0.0428 0.0465 0.0973 0.118 0.112 0.0597 0.0768 0.0397 0.0358 0.327 0.0708 0.0373 0.0359 pCi/.g PC/.
pCi/.g pCi/gO pCi/g pCV/g pCi/.g pCi/g-pCi/g" PCitg pCi/.g pCi/'g pCg~
pCi/g pCi/gO pCi/O pCi/.g MJH. 10/02/06. 1344 574334. 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09/10/06 1536 570843 The rullowing Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A qUality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 70
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID.:
9530-0001-014FS Protect:
YANKO 1204 Sample 1)D.
172114019 Client ID:
YANK00I Vol. Recv.:.
Parameter Qualifier Result Uncertainty LC ThU NInA Units DF Analyst Date Time Batch Mt Result is greater than value reported A
The TIC is a suspected aldol--.condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Anatyte has been confirmed by GC/MS analysis D
Results are reported from a dilutedaliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by. 4X or more R
Sample results are rejected.
U Analyte was analyzed for; but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case.Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked.with this compound A
.RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
71
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 -. www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy
.Project:
Soils PO# 002332 Report Date: October'4, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
- 9530-0001--015F
- 172114020 TS 08-SEP-06 20-SEP-06 Client 11.3%
Pro iect:
YANKO 1204 Client ID:
YANKOO1 Vol. Recv.:
Paramneter Qualifier Result Uncertainty.
LC TPU NIA Units DF Analyst Date Time Batch Mt Rad Gamma Spec Analysis
. Ganma.Solid-FSS GAM &.ALL FSS 226 higrowih':
.Waived..
Actinium-228
.0.644
+/"0.161 Ai-nericiumý-241 U
-0.0336
+1-0..109.
Bismutih-212 "0.569
+/-0.273 B ismuth-214 0.449
+/-0.0867 Cesium-134 U
0.0226
+/-0.0592 Cesium-137 0.0415
+1-0.0554 Cobalt-60 U
0.00214
+/-0.021 Europium-152 U
-0:0102.
+/-0.0545 Europium-154 U
-0.0195
+/-0.0706 Europium-155 U
.0.0685
+/-0.0967 Lead-2 12 0.695
"-/-0.065 Lead-2 14 0.496
-/-0.0794 Manganese-54 U
0.0025
+/-0.0231 Niobium-94 U 0.00735
+/-0.0205 Potassium-40 12.0
+/-0.924 Radium-226 0.449
+/-0.0867 Silver-t08m U
-0.0174
+/-0.0168 Thallium-208 0.218
+/-0.0517
.0:0631.
0.0844
' 0.122 0.0328 0.0218
.0.0185.
- 0.0179 0.0452 0.0576
..0.0485 0.0273 0.0352 0.0194 0.0179 0.137 0.0328 0.0136 0.0177
+/-/-0.161
.1*-109
+/-0.273
+/-0.0867
+/-0.0592
+/-0.0554
+/-0.021:
+1-0.0545
+/-0.0706
+/-0.0967
+1-0.065
+1-0.0794
+/-0.0231
+/-0.0205
+/-0.924
+/-0.0867
+/-0.0168
+/-0.0517 0.138 0.176
- 0.266 0.0703 0.0468
.0.0397 0.0403 0.0957 0.127 0.101 0.0571 0.0743 0.042 0.0383 0.318 0.0703 0.0293 0.0379 pCi/g2 pCi/g pCil.
pCig.1 pCi/g.
pCi/.0 pCi/gO pCilg pCi/g1 pCi/g.
pCi/gO pCi/gV MJHI 1.0/02/06 1345 574334 The foliowing Prep Methods were performed Method Description Analyst.
Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 09/20/06 1536 570843 The following Analytical Methods were performed Method Description I
EML HASL 300. 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 72
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 4, 2006 Contact.
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9530-00l-1-015F Project:
YANK01204 Sample ID:.
172114020 ClientID:
YANK001 Vol. Recv.:
Parameter QJualilher Result Uncertainty LC TPU vflfJA Units OF Analyst Date Time Batch Mt.
Result is greater than value reported A.
The TIC is a suspected akdol-condensation product; B..
Target analyte.was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed.by GC/MSanalysis D..
Results are reported from a diluted aliquot of the sample II Analytical holding time was exceeded J. Value is estimated N/A Spike recovery limits do not apply. Sampleconcentration exceeds spike concentration by 4X or more.
..R Sample results are.rejected U
Analyte was analyzed for, butnot detected above the MDL, MDA, orLOD.
UI Gamma Spectroscopy-Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Mvianager concerning this qualifier Y
QC Sarmples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
73
Fr QUALITY C.ONTRO.L DATA 74
GENERAL.ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com OC Summary Client:
Connecticut Yankee Atomic Power 362 Injun Hollow Rd Report Date: October 4, 2006 Page 1 of 9 East Hampton, Connecticut
Contact:
Mr. Jack McCarthy Workorder:
172114 Parmname Rad Alpha Spec Batch 572120 140-1"M.p
-Q.
QC Units RPD%.
REC%
Rage AnIst Date. Time QC1201191304 172114001 DUP Amnericium2
-.2.4 Curiiim-243/244, U
- 0.0864 Uncert:
+1-0.105 TPU:
+/-0.106 U
0.00 Uncert:
+/-0.0553 TPU:
+/-0.0553 U
0.0664 Uncert:
+i-0.0911 TPU:
+/-0.0915 QC.1201191306 Americium:241 Curittnn-242" Curium-243/244 QC1201191303 Americium-241
" LCS MB 11.4 Uncert:
TPU:
Uncert:
. TPU:
13.7 Uncert:
TPU:
Uncert:
TPU:
Uncerl:
TPU:
Unccrt:
TPU:
U 0.0286.
..*+1-0.0554
+/-0.0555 U
-0.0072
+/-0.0141
+1-0.0141 U
-0.00672
+/-0.0132
+/-0.0132
+1-I.20
+1-1.96.
U.
0.0299
+/-0.0586 41-0.0588
.14.4
+/- 1.28
+/-2.18 U
0.00455 4t-0.0226 4/-0.0227 U
0.00
+/-0.0581
+/-0.0581 U
-0.0704
+1-0.0436
+1-0.0445 pCi/g.
101 pCi/g 200 (0% - 100%)
pCi/g 245
.(0% -'100%)
pCi/g Ill. (75%-125%)
pCi/g pCi/g 105.( /a-125%)
(0% -. 100%)
TC1 09/28/06.11:56 Curium-242 Curium-243/244 QC1201191305 172114001 MS Amcricium-24 I Curium-242 Curitim-243/244.- *..
PCi/0 pCi/.g pCi/g PCi/g PCi/g 12.0 Uncen:
TPU Uncent:
TPU
-14.5---
Uncert:
TPU U
0.0864
+/-0.105
+/-0.106 U
0.00
+/-0.0553
+/-0.0553 U--
-- 0.0664.
+/-0.0911
+/-0.0915 U
12.9
+1-1.10 4/-I.85
-0.0126
+1-0.0175 410.0175
-14.4 W-1.16
+W-2.03 108 (75%-125%)
99---(75%:125%)-
Batch 572121 QCI201191308 172114001 DUP Plutonium-238 U
- 0.102 U
0.0358 pCi/g
- 96.
(0%- 100%)
TCI 09/28/06 11:56 75
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171. - www.gel.com QC Summary Workorder:
172114 Parmname Rad Alpha Spec Batch 572121 Page 2 of 9 Units RPD%
REC%
Range Anist Date Time NOM Sample Qual QCC Plutonium-239/240 QCI2011913.10 LCS Plutonium-238.
Plutonium-239/240 QCI1 O11913O7 MB Plutonium-238 Plutonium-239/240 QCI201191309 172114001 MS Plutonium-238 Plutonium-239/240
" Uncert:
+/-0.0996 TPU:
+1-0.100 U
0.062 Uncert:
.+-0.077 TPU:
+/-0.0773 Uncert:
TPU:
10.5 Uncert:
TPU:
Uncert:
TPU:
- Uncert:
TPU:
u 0.102 Uncert:
+/-0.0996 TPU:
+/-0.100 11.1 U
.0.062 Uncert:
+/-0.077 TPU:
+/-0.0773 U
6.10 Uncert:
+/-8.99 TPU:
+/-9.01
+/-0.0808
+/-0:0809 U
-0.0313
+/-0.0909
+/-0.091 U
0.0404
- ..+1-o.0758
+1-0.0759 11.2
+/-1.07
+/-1.73 U
0.00363
+1-0.114
+/-0.114 U
0.0618
+/-0.107
- +/-0.107 pCi/g
.608 (0%- 100%)
pCi/g pCilg pCi/g PC/-.
pCiug pCi/g pCi/g
..(75%-.125%)
107 (75%-125%)
09/28/06 11:56
.U 0.0976
+/-0.102
+1-0.103 11.9
+1-1.09
+/-1.79 (75%-125%)
09/28/06 11 -56 107.75%-125%)
Batch 572122 QCI201191312 172114001.DUP Plutonium-24 I QC020119t314 LCS Plutonium-24 I QC1.201191311 JOB Plutonium-241 QCI201191313 172114001 MS Plutoni.um-24 I Rad Gamma Spec Batch 574334 QC1201196534 1721t4006 DUP Actinittm-228 U
4.20
+/-8.54
+1-8.55 pCi/g 0
(0%- 100%)
TCI 132 Uncert:
TPU:
112
+1-12.9
+1-17.0 Uncert:
TPU:
144 U
Utwert:
I.- "iPU:
U 2.21
+/-8.86
+1-8.86 pCi/g pCilg pct/g.
85 (75%-125%)
09/29/06 23:34 09/30/06 00:06 09/29/06 23:18 09/29/06 23:50 6.10
+/-8.99
,+/-9.01 141
+ý-14.2 A-119.8.
98 (75%-125%)
0.828 Uncert:
+/-0.191 0.724
+/-0264 1-0264 PCi/g 13 (0% - 100%) MlJH 1I 10/02106 13:46 76
GENERAL ENGINEERING LABORATORIES, LLC
.2040 Savage Road Charleston SC 294(17 - (843) 556-8171 - wvvw.gel.com Workorder:
172114 Rad Gamma Spec Batch 574334 QC Summary Page 3 of 9 SampleQual QC Units RPD%
REC%
Range Anist Date Time NOM Americium-241 Bismuth-212 Bismuth 2 14 Cesium-134 Cesium-137 Cobalt-60 Eutopium-.152 Europium-154 Europium-155 TPU:
+4-0.191 U
-0.0107 U
0.00921 pCi/g 2710 Uncert:
+1-0.0746 0.0404 TPU:
+1-0.0746.
.1-0.0404 E0881 0.621 pCi/g 35 Unce i:
+/-0.459
+1-0284 TPU.
+/-0.459
+1-0.284
.0.612
- 0.719 pCi/g 16.
Uncert:
+/-0.130
+140.131 TPU:
+1-0.130
+14.131 UI 0.00 U
0.00367 pCi/g 184 Uncert:
+/-0.0376
+4-0.0364 TPU:
+/-0.0376
+/-0.0364 0.182' 0227 pCi/g 22 Uncert:
+/-0.0483
+140551 TPU:
+/-0.0483.
4-0.0551 U
-000988 u.-DW0503.
pCi/g 65 Uncert:-
+/-0.0263
+1/-.09-77..-
TPU:
+4-0.0263.
+1-0.0277 U
0.0683 U
-0.11.2 pCi/g 825 Uncert:
+/-0.0624
+1-0.0713 TPU:
+/-0.0624
+1-.0713 U
0.104 U
0.0469 pCi/g 76 Uncert:.
4*1-0.0885
+1-0.0793 TPU:
+/-0.0885
+1-0.0793 U
.0.0308 U
0.046 pCi/g 40 Uncert:
+1-0.0643
.+1.0.0633 TPU:
. +/-0.0643
+1-/40633 0.882 0:876 pCilg I
Uncert:
+1-0.0991
+b-=3 12 TPU:
+/-0.0991
+/4.0812 0.857 0.790 pCilg 8
Uncert:
+/-0.131
+1-0.136 TPU:
+1-0.131
+14-0:136
. U 0.000152 U
0.0209 pCi/g 197 Uncert:
+/-0.0265
+1-0_0328 TPU:
+/-0.0265
+/-0.0328 U
0.02P79 UI 0.00 pCi/g 132 Uncert:
+/4.U02.15
+/-A0533 TPU:
+/-0.0215
+/-0.0533 13.3 14.6 pCi/g 10 Uncert:
+1-1.37 4k 19 TPU:.
-W-14:1*37
.4-I19 0.612 Q319 pCi/g 16 Uncern:
+/4130 41-0.131 TPU:
+1-0.130 W4-0.131 U
-0.00885 U
-0.0074 pCi/g 18 Uncert:
+/-0.0202
+14L0243 (0%- 100%)
(0%- 100%)
(0%- 100 %)
(0%- 100%)
(0%- 100%)
(0%- (00%)
(0%- IO0%)
(0% - 100%)
(0% - 20%4)
(0% - 100%)
(0%- 100%)
(0% - 20%)
(0% - 10o%)
(0%- 100%)
Lead-2 12 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-10gmi 77
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Workorder:
1721:
Parmname
" Rad Ganmma Spec Batch.
574334 Thallium-208 OC Summary 14 Page 4 of 9 NOM Sample Qual QC Units RPD%
REC%
Range Anist Date Time
.Qia
.A~
TPU:
+1-0.02 0.282 Uncert:
+1-0.0618 TPU:
+/-0.0618.
+"-0.0243 0.260
- +1-0.0691
+0.0691 pCilg 8
(0%-100%)
pCilg QCI201196535 Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60.
Europium-152 Europium-154 Europium-155 LCS Uncert:
TPU:
23.4..
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:.
Unceri:
TPU:
- 9.56 Uncert:
TPU:
14.4 Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
U
-0.0425
+1-0.520
+/-0.520 23.8
+1-1.09
+1-1.09 U
-0.416
+/-0.904
+/-0.904 U 0594
"+-0221
".-0221 U
0.0337
+1-0.137 "1-0.137 10.2
+/-0.440
"/-0.440 15.0.
- /-0.617
+/-G.617 U
-0.0589
-O0260
,14-260 U
0.123
+W-0 253
+/-0.253 U
0.0288 W1-0280
+1-0.280 U
0.0247 4-0.147
,-0.147 U
0,126 405190 414-190 U
-4137 4&!20 U
a0.018
+/-0.112 W/-0.112 U
0.273 Pci/k pCi/g pCi/g.
pCi/g pCilg-PCi/g pCi/g1 pCi/g-102 (75%-125%)
10/02/06 13:46 107 (75%-125%)
104 (75%-125%)
Uncert:
TPU:
Lead-212 Lead-214 Nlansnese-54 NioIbium-94 Potassium-40 Uriceri:
TPU:
uncert:
TPU:
Unceit:
TPU:
Uncert:
TPU:
78
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gei.com Workorder:
172114 Parmname Rad Gamma Spec Batch 574334 QC Summary Page 5 of 9 NOM N!
Sample QuaI_ _ _QC Units RPD%
REC%
Rang.e Anlst Date Time Tim Radium-226 Silvel -108m Thallium-208 QC201196533 MB Actinium-228 Americiumn-24 "
Bisrnuth-2 12 Bismuth-214 Cesium-134 Cesium-137 Uncert:
TPU:
Uncert:
TPU:
Uncer't:.
TPU:
Uncert:
TPU:
Uncet:
TPU:
- Uncert:
TPU:1
- Uncert:
TPU:
Unceii:
TPU:
Uncert:
TPU:.
Unceit:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Ucert:
TPU:
TPU:
Uncert:
TPU:
+1-0.940
+1-0.940 U
-0.0594
+/i-0221 4+-0.2 I U
0-0133
+/-0.0983
+1-0.0983 u
-0.0156
+1-0.108
+1-0.108 U
'0.0198
+/40.0496
+/-0.0496 U
0.0304
+1-0.0722 q/-0.0722 U
-0.0547
. 1-0.097
+1-0.097 U
0.0089
+/-0.0274.
+1-0.0274 U
0.0013
+/-0.0141
+/4-0141 U
-.0.,0185
+1-0.12'7
+/-140127 U
01)0854
+MD1.0131
+/A0.0131 U
0.0369
+1-0.0388
+/-0.0388 U
_{0L1458
+/-0,0366
+/-4.1Y366 U
-0.W598
+/1-03.42
+I-01J342 U
11@.49
+/41114M
+/-4-0456 U
0.00865
+1-0.0381
+/1.00381 pCi/g pCi/g-pCi/g pCi/.g pCi/g.
pCi/a-pci'8-pCi/g.
pci/g, (75%7-125%)
10/02/06 13:45 Cobalt-60 Europium-152 Europium-154 Europium-155
-Lead-212 Lead-214 79
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road. Charleston SC 29407 - (843) 556-8171 - www.gel.com Workorder:
172114 Rad Gamma Spec Batch 574334 Mianganese-54 Niobium-94 Potassium-40 Uncert:
S TPU:
Uncert:
TPU:
uncer:.
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
QC Summary Sample Qua.
QC__
U 0.00522
+/-0.0132 S+1-0.0132 U
. 0-0114
+1-0.00966.
+40.00966 U
0.0292
+/-0.282
+/-0.282 U
0.0089
+/-0.0274
+/-0.02-74 U
0.00301
+1-0.0115
+14):0115 U
0.0143 41-0.0139
+1-0.0139 Page 6 of 9 Units RPD%
REC%
Range Anlst Date Time pCi/g pCi/g pCi/g pCi/g.
pCi/g Radiuim-2 216 Silver-108m Thallium-208 Rad Gas Flow Batch 571177 QC1201189313 172114001 DUP Strontium-90 QCI[201189315 LCS Strontium-90 QC1201189312 MB Stlontium-90 QC1201189314 172114001 MS Strontium-90 Rad Liquid Scintillation Batch 570929 QC1201188776 172114010 DUP Iron-55 QCI201188778 LCS Iron-55 QC1201188775 MB hun-55 U
0.00276 Uncert:.
/-0.00637 TPU:
+/-0.00637 1.74 Uncert" TPU:
Uncerl.:
TPU:
U 0.00958
+0.00698
+/-0.00699 1.61
.4/-0.0822 4M0946 U
01)00716
+1-0.00594
+1-0.00594 1.63 0.0859
+1-0.0982 pCi/g 0
(0% - 100%) KSDI pCi/g.
pCi/g, pCi/g, "93 (75%-125%)
94 (75%-125%)
09/29/06 23:36 09/30/06 08:48 09/29/06 23:36 09/30/06 08:48 1.74 U
Uncert:
.TPU:
0.00276
+/-0.00637
+/-0.00637 U
12.2 tlncert:
+/-25.2 TPU:
+/-25.2 U
-0.391
+/-32.7
.1432.7 537
+1-45.3
+1-59.7 pCi/g 0
(0% - 100%) VIXPI 09/27/06 14:03 621 Uncern:
TPU:
pC-I/g 86 (75%-125%)
09127/06 14:36 10/03/06 05:37 U
22.8 pCi/g 80
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Workorder:
172114 Parmname Rad Liquid Scintillation Batch 570929 OC Summary Sample Qual ___QC NOM Page 7 of 9 Units RPD%
REC%
Range Anlst Date Time Uncert:
TPU:
QC0201188777 172114010 MS lron-55
+1-41.7
+/-41.7 667
+1-45.8
+/-64.5 699 U
Uncert:
TPU:
12.1
+1-25.2
+1-25.2.
pCi/g 95 (75%ý125%)
09/27/06 14:19 Batch 570930 QC1201188781 172114010. DUP Nickel-63 QC1201188783 Nickel-63 LCS U
-5.95 Uncert:
+/-10.8 TPU:
+/-10.8 512.
Uncert:
TPU:.
Uncert:
TPU:
QC1201188780 MB Nickel-63 QC1201188782 172114010 MS Nickel-63 U
- 2.04
+4-8.19
+/-8.19 427
+/-21.0
+/-25.0 U
4.54
+-/-10.3
+/-10.3 467
+--24.9
+/-29.5 pCi/g pCi/g pci/g.
83 (75%-1-5.%)
82 (75% 125%)
09/25/06 17:40 09/25/06 16:50 09/25106 17:23 pCi/g 0
(0%- 100%) VIXPI 09/25/06 17:07 571 U
Unceit:
TPU:
-5.95
+/-10.8
+/- 10.8 Batch 570932
. QC1201188785
.Technetitim-99 172114001 DUP
- u.
0.0384 Uncert:
+/-0.285 TPU:
+/-0.285 U
Q01201188787 LCS Technetiurn-99 0.0669
+/-0.286
+W-0286.
13.8
+/-0.523
+/-0.610 pCi/g 0
(0% - 100%) KXR I QC1201188784 Technetium-99 NIB QC1201188786 172114001 MS Technetium-99 12.7 Uncert:
TPU:
Uncert:
TPU:
13.1 U
Uncert:
TPU:
U Uncert:
TPU:
54.5 Uncert:
TPU:
U 0.0777
+1-0.247
+1-0.247 pCi/g pci/g 109 (75%-125%)
09/29/06 17:06 09/29/06 17:39 09/29/06 16:50 09/29/06 17:23 Batch 570933 0.0384
+/-0.285
+/-0.285
-5.59
+/-7.85
+/-7.85 QC1201188789 172114001 DUP Tritium QC1201188791 LCS Tritium U
13.4
",-0-575
-04651
-W-728
+/-7.28 49.4
+/-9.21
+1-9.25 103 (75%-125%)
- iig 0
(0% - 100%) DFAI 09/2_5/06 02:59 pCi/g 91 (75%-125%)
09/25/06 03:31 81
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Workorder:
172114 Parmname Rad Liquid Scintillation Batch 570933 QCI20H188788 MB Tritium QC1201.188790 :172114001 MS Tritium.
QC Summary Page 8 of 9 NOM Sample Qu.Il QC Units RPD%
REC%
Range Anlst Date Time Uncert:
TPU:
U 1.22
+/-6.42
+/-6.42 pCi/g PCi/
09/25/06 02:42 09/25/06 03:15 54.5 U
Uncer.
TPU:
-5.59
+/-7.85
+/-7.85 41.0
+/-8.97
+1-9.00 75 (75%-125%)
Batch
QC1201188794 172114010 MS Carbon-.14 U
0.00 Uncert:
+/-0.0813 TPU:
+/-0.0813 U
-0.026
+/-0.0763
+/-0.0763.
6.32
+/-0.448
+/-0.458.
pCi/g 0
(0% - 100%) 6,XD2 09/23/06 16:34 6.57
- Uncern:
TPU:
Uncers:
TPU:
7.05 U
Uncert:
TPU:
U
- -0.0391.
+/-0.0746
+1-0.0746 pCi/g pCi/g pCi/g 96 (75%-125%)
09/23/06 17:34 09/23/06 15:52 09/23/06 1.7:17
.0.00
+/-0.0813
+/-0.0813
. 6.69
+/-0.468
+/-0.479
.95 (75%-125%)
Notes:
The Qualifiers in this report are defined as follows:
A B
BD C
D H
J N/A
-R U
Ul X
Y A qttlity control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported The TIC is a suspected aldol-condensation product Target analyte was detected in the associated blank Results are either below the MDC or tracer recovery is low Analyte has been confirmed by.GC/lvlS analysis Results are reported from a diluted aliquot of the sample Analytical holding time was exceeded Value is estimated Spike recovery limits do not apply. Sample concentration exceeds spike concentralion by 4X or more
-Sample results-are rejected------------...
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
Gamma Spectroscopy--Uncertain identification Consult Case Nanative, Data Summary package, or Project Manager conceming this qualifier.
QC Samples were not spiked with this compound RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL 82
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:
172114 Page 9 of 9 parmna~me
_NOM Sample Qual C
Units RPD%
REC%
Range Artist Date Time A
"h Prepaiation or preservationholding time was.exceeded.
NIA indicates that spike recovery limits do not apply when sample concentration exceeds spike cone. by a factor of 4 or more.
- Indicates analyte is a surrogate compound.
A The Relative Percent Difference (RPD) obtained from the gample duplicate (DUP).is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (Rn). In cases.where either the sample or duplicate value is
.less than 5X.the RL,a control limit of+/- the.
R.L is used to evaluate the DUPresult.
For PS, PSD. and SDILT results, the values listed are the measured amounts, not final concentrations.
SWhere the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.
83
CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD ATTACHMENT 4 (DQA RESULTS)
CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD ATTACHMENT 4A (PRELIMINARY DATA REVIEW)
PRELIMINARY DATA REVIEW FORM Survey Unit:
Survey Unit Name:
Classification :
9530-0001 Central Peninsula 2
Survey Media:
Soil Type of Survey:
Final Status Survey Type of Measurement:
Radionuclide Specific fumber of Measurements :
15 BASIC STATISTICAL QUANTITIES Cs-137 Target Level (pCi/g):
5.38E+00 Minimum Value:
4.15E-02 Maximum Value:
2.59E-01 Mean:
1.09E-01 Median:
1.21E-01 Standard Deviation :
5.40E-02 Sample Identification 9530-0001-001F 9530-0001-002F 9530-0001-003F 9530-0001-004F 9530-0001-005F 9530-0001-006F 9530-0001-007F 9530-0001-008F 9530-0001-009F 9530-0001-OIOF 9530-0001-01 IF 9530-0001-012F 9530-0001-013F 9530-0001-014F 9530-0001-015F Reported Results Cs-137 Concentration (pCi/g) 1.30E-01 1.27E-01 2.59E-01 1.3 1E-01 4.85E-02 1.21E-01 1.34E-01 1.33E-01 6.41E-02 1.34E-01 1.06E-0 I 8.50E-02 7.29E-02 5.47E-02 4.15E-02 Detect?
+
+
+
+
+
+
+
+
+
+
+
+
+
+
Fraction of Target Level 0.024 0.024 0.048 0.024 0.009 0.022 0.025 0.025 0.012 0.025 0.020 0.016 0.014 0.010 0.008 J;F C te-i-ecvL ý("
/, // -Oe-1 of 1
CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD ATTACHMENT 4B (GRAPHICAL REPRESENTATION OF DATA)
FREQUI;NC.Y P1,OT FOR CESIUM-137 Survey Unit: 9530-0001 Survey Unit Name: Central Peninsula M4ean: 1.09E-0 I pCi/g Frequency Plot For Cs-137 10
(.)
Ca) 0*
4)
L.
LL 8
6 4
2 0
R~-------------
4.15E-02 9.33E-02 1.45E-01 1.97E-01 2.49E-01 3.01E-01 Upper End Value (pCilg)
Ir 'r r I Upper End Value 4.15E-02 9.33 E-02 1.45E-01 1.97E-01 2.49E-01 3A01E-01 Total:
Observation Frequency 8
0 0
15 Observation Frequency 7%
53%
0%
0%
7%
100%
Submitted by? ate.-
Review by/Dat 1o 1 of 1
. QUANTILE PLOT FOR CESIUM-137 Survey Unit:
9530-0001 Survey Unit Name: Central Peninsula Mean:
1.09E-01 pCi/g Quantile Plot For Cs-1 37 2.50E-01 K
0)
C-)
2.OOE Li 0-~ 1.50E-01 U 1.00E-01 5.O0E-02 0.00E-'00 i
M m
I.
UM 0
20 40 60 Percentage 80 100 Cs-137 4.15E-02 4.85E-02 5.47E-02 6.4 1E-02 7.29E-02 8.50E-02 1.06E-01 1.21E-01 1.27E-01 1.301I701 1.3 1 E-01 1.33 E-01 1.34E-01 1.34E-01 2.59E-01 Rank 2
2.
4 5
6 7
8 9
10 11 12 13 14 15 Percentage 3%
10%
17%
23%
30%
37%
43%
50%
57%
63%
70%
77%
83%
90%
97%
/
Submitted byDate/
Revie
.d by/Da z0 4 3 lo~a
CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD ATTACHMENT 4C (SIGN TEST)
Connecticut Yankee Decommissioning Project Health Physics Procedure GPP-GGGR-R5121-001 Attachment A, Rev CY-001 MAJOR Sign Test Calculation Sheet For A Single Radionuclide or Gross Activity Measurements Survey Area Number: 953 0 Survey Unit Number: 000 1 Survey Area Name: Central Peninsula Survey Area Number: 9530 Survey Unit Number: 0001 Survey Area Name: Central Peninsula WPIR#: 2006-0038 Classification: 2 Type I (ac error): 0.05 (N): 1.5 Radionuclide: Cs-137 DCGL: 5.38 Results (pCi/g)
DCGL - Results Sign 1.30E-01 5.25E+00 1
1.27E-01 5.25E+00 I
2.59E-01 5.12E+00 1
1.31E-01 5.25E+00 1
4.85E-02 5.33E+00 I
1.21E-01 5.26E1+00 1
1.34E-01 5.25E+00 I
1.33E-01 5.25E+00 1
6.41E-02 5.32E+00 I
1.34E-01 5.25E+00 1
1.06E-01 5.27E+00 8.50E-02 5.30E+00 I
7.29E-02 5.3 1E+00 5.47E-02 5.33E+00 I
4.15E-02 5.34E+00 Number of positive differences (S+): 15 Critical Value: I I Perfoe ried by:
.;kdef--
Independent Review by.
Survey Unit Meets Acceptance Criterion Date:.......
Date:
I Page 1 of I
CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD ATTACHMENT 4D (QC SPLIT RESULTS)
Health Physics Procedure 24265-000-GPP-GGGR-R5124-000-Rev.CY-000 Attachment A Health Physics Procedure 24265-000-GPP-GGGR-R5 1 24-000-Rev.CY-O00 Attachment A Split Sample Assessment Form Survey Area#: 9530 Survey Unit #: 0001 Survey Unit name: Central Peninsula Sample Plan or WPIR#: 2005-0038 SML#: 9530-0001-006 Sample
Description:
Comparison of split samples collected from sample measurement location #6 and analyzed using gamma spectroscopy by off-site Vendor Laboratory. The standard sample was 9530-0001-006F, the comparison sample was 9530-0001-006FS.
STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable Value Error Range Value Error Ratio (Y/N)
Cs-137 1.21E-1 1.38E-2 9
0.6-1.66 1,24E-I 2.27E-2 1.02 Y
Commentsiuorrecnve Actions: IN//A I able is provioed to snow acceptance criteria used to assess split samples.
Resolution Agreement Range 4-7 0.5-2.0 8-15 0.6-1.66 16-50 0.75-1.33 51 -200 0.80- 1.25
>200 0.85-1.18 Page 1 of I
Health Phvsics Procedure 24265-000-GPP-GGGR-R5124-000-Rev.CY-000 Attachment A Health Physics Procedure 24265-O0O-GPP-GGGR-R5 I 24-000-Rev.CY-000 Attachment A Split Sample Assessment Form Survey Area#: 9530 Survey Unit #: 0001 Survey Unit name: Central Peninsula Sample Plan or WPIR#: 2005-0038 SML#: 9530-0001-014 Sample
Description:
Comparison of split samples collected from sample measurement location #14 and analyzed using gamma spectroscopy by off-site Vendor Laboratory. The standard sample was 9530-0001-014F, the comparison sample was 9530-0001-014FS.
STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable Value Error Range Value Error Ratio (Y/N)
K-40 1.25E1 6.55E-1 191 0.8-1.25 1.22E1 5.40E-1 0.98 Y
Comments/Corrective Actions: Cs-137 was not detected in sufficient quantities to evaluate in accordance with procedure Table is provided to show acceptance criteria used to assess split samples.
Resolution 4-7 8-15 16-50 51 -200
>200 Agreement Range 0.5-2.0 0.6 - 1.66 0.75-1.33 0.80 - 1.25 0.85-1.18 C/
Page 1 of I
CENTRAL PENINSULA SURVEY UNIT 9530-0001 RELEASE RECORD ATTACHMENT 4E (COMPASS DQA WITH POWER CURVE)
-1, DQA Surface Soil Report Assessment Summary Site:
Planner(s):
Survey Unit Name:
Report Number:
Survey Unit Samples:
Reference Area Samples:
Test Performed:
Judgmental Samples:
Assessment
Conclusion:
9530-0001 FSS McCarthy Central Peninsula 1
15 0
Sign Test Result:
Not Performed 0
EMC Result.
Not Performed Reject Null Hypothesis (Survey Unit PASSES)
.Retrospective Power Curve 0.9 -4
=4-0.7
?, 0.6 4
=04 0.3
.- 0.2
= 0.1 P
0o 0
1 2
3 4
5 Soil Concentration (p Ci~g), including background Prospective Power 0
1-beta Actual Power LBGP.
Estimated Power DCGL I.
Retrospective Power 6
COMPASS v0..0.P 10/19/2006 Page1I