MONTHYEARML24256A0282024-09-12012 September 2024 2024 Hatch Requal Inspection Corporate Notification Letter NL-23-0930, Application to Revise Technical Specifications to Adopt TSTF-591, Revise Risk Informed Completion Time (RICT) Program2024-09-11011 September 2024 Application to Revise Technical Specifications to Adopt TSTF-591, Revise Risk Informed Completion Time (RICT) Program NL-24-0337, Interim 10 CFR 21.21(a)(2) Report Regarding Operation Technology, Inc., ETAP Software Error in Transient Stability Program2024-09-0909 September 2024 Interim 10 CFR 21.21(a)(2) Report Regarding Operation Technology, Inc., ETAP Software Error in Transient Stability Program ML24249A1362024-09-0404 September 2024 EN 57304 - Westinghouse Electric Company, LLC, Final Report - No Embedded Files. Notification of the Potential Existence of Defects Pursuant to 10 CFR Part 21 NL-24-0334, 0 to the Updated Final Safety Analysis Report, Technical Specifications Bases Changes, Technical Requirements Manual Changes, License Renewal 10 CFR 54 .37(b) Changes, 10 CFR 50.59 Summary Report & Revised Nrc2024-09-0303 September 2024 0 to the Updated Final Safety Analysis Report, Technical Specifications Bases Changes, Technical Requirements Manual Changes, License Renewal 10 CFR 54 .37(b) Changes, 10 CFR 50.59 Summary Report & Revised Nrc IR 05000321/20240912024-08-27027 August 2024 NRC Investigation Report 2-2023-003 and NOV - NRC Inspection Report 05000321/2024091 and 05000366/2024091 IR 05000321/20240052024-08-26026 August 2024 Updated Inspection Plan for Edwin I. Hatch Nuclear Plant, Units 1 and 2 - Report 05000321/2024005 and 05000366/2024005 NL-24-0313, Application to Revise Technical Specifications Surveillance Requirements to Increase Safety/Relief Valves Setpoint Response to Request for Additional Information2024-08-23023 August 2024 Application to Revise Technical Specifications Surveillance Requirements to Increase Safety/Relief Valves Setpoint Response to Request for Additional Information IR 05000321/20240022024-08-0808 August 2024 Edwin I Hatch Nuclear Plants, Units 1 and 2 – Integrated Inspection Report 05000321-2024002 and 05000366-2024002 NL-24-0290, Response to Request for Additional Information Related to Request for Specific Exemption2024-07-26026 July 2024 Response to Request for Additional Information Related to Request for Specific Exemption NL-24-0276, Post-Audit Supplement to License Amendment Request to Revise Renewed Facility Operating Licenses to Adopt an Alternative Seismic Method for Categorization of Structures, Systems, and Components2024-07-26026 July 2024 Post-Audit Supplement to License Amendment Request to Revise Renewed Facility Operating Licenses to Adopt an Alternative Seismic Method for Categorization of Structures, Systems, and Components NL-24-0261, 10 CFR 50.46 ECCS Evaluation Model Annual Report for 20232024-07-19019 July 2024 10 CFR 50.46 ECCS Evaluation Model Annual Report for 2023 ML24198A1252024-07-16016 July 2024 Edwin I Hatch Nuclear Plant Units 1 - 2 Notification of Conduct of Title 10 of the Code of Federal Regulations 50 NL-24-0260, Inservice Inspection Program Owner’S Activity Report (OAR-1) for Refueling Outage 1R312024-07-0909 July 2024 Inservice Inspection Program Owner’S Activity Report (OAR-1) for Refueling Outage 1R31 NL-24-0240, Reactor Core Isolation Cooling (RCIC) System Inoperable Due to Mispositioned Link2024-07-0303 July 2024 Reactor Core Isolation Cooling (RCIC) System Inoperable Due to Mispositioned Link NL-24-0237, Incorrectly Installed Temporary Modification Results in Multiple Conditions Prohibited by Plant Technical Specifications2024-07-0303 July 2024 Incorrectly Installed Temporary Modification Results in Multiple Conditions Prohibited by Plant Technical Specifications NL-24-0143, Proposed Alternative to Use ASME Code Case N-752, Risk-Informed Categorization and Treatment for Repair/ Replacement Activities in2024-06-27027 June 2024 Proposed Alternative to Use ASME Code Case N-752, Risk-Informed Categorization and Treatment for Repair/ Replacement Activities in NL-24-0239, Response to Apparent Violation in NRC Inspection Report 05000321, 366/2024090: EA-23-1392024-06-17017 June 2024 Response to Apparent Violation in NRC Inspection Report 05000321, 366/2024090: EA-23-139 ML24163A0532024-06-14014 June 2024 Audit Plan - Alternative Seismic Method LAR ML24149A0492024-06-0404 June 2024 SNC Fleet - Regulatory Audit in Support of Review of the License Amendment Request to Revise TS 1.1, Use and Application Definitions, and Add New Technical Specification 5.5.21 and 5.5.17, Online Monitoring Program, NL-24-0148, Report of Changes to Emergency Plan and Summary of 50.54(q) Analysis2024-06-0404 June 2024 Report of Changes to Emergency Plan and Summary of 50.54(q) Analysis NL-24-0202, SNC Response to Regulatory Issue Summary 2024-01: Preparation and Scheduling of Operator Licensing Examinations2024-05-24024 May 2024 SNC Response to Regulatory Issue Summary 2024-01: Preparation and Scheduling of Operator Licensing Examinations IR 05000321/20240902024-05-15015 May 2024 NRC Inspection Report 05000321-2024090 and 05000366-2024090, Investigation Report 2-2023-003; and Apparent Violation NL-24-0191, Annual Radiological Environmental Operating Reports for 20232024-05-10010 May 2024 Annual Radiological Environmental Operating Reports for 2023 NL-24-0166, Manual Reactor Trip Due to Loss of Feedwater2024-05-0909 May 2024 Manual Reactor Trip Due to Loss of Feedwater NL-24-0195, Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times for Residual Heat Removal Service Water.2024-05-0707 May 2024 Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times for Residual Heat Removal Service Water. NL-24-0064, Units 1 & 2 and Hatch Nuclear Plant - Units 1 & 2 License Amendment Request to Revise Technical Specification 1.1 and Add Online Monitoring Program to Technical Specification 5.52024-05-0303 May 2024 Units 1 & 2 and Hatch Nuclear Plant - Units 1 & 2 License Amendment Request to Revise Technical Specification 1.1 and Add Online Monitoring Program to Technical Specification 5.5 NL-24-0165, Annual Non-Radiological Environmental Operating Reports and Annual Radioactive Effluent Release Reports for 20232024-04-25025 April 2024 Annual Non-Radiological Environmental Operating Reports and Annual Radioactive Effluent Release Reports for 2023 IR 05000032/20240112024-04-25025 April 2024 Notification of Edwin I. Hatch Nuclear Plant - Comprehensive Engineering Team Inspection (CETI) Baseline Inspection Report 0500032/2024011 and 05000366/2024011 NL-24-0157, Incorrectly Installed Temporary Modification Results in a Condition Prohibited by Plant Technical Specifications2024-04-24024 April 2024 Incorrectly Installed Temporary Modification Results in a Condition Prohibited by Plant Technical Specifications IR 05000321/20240012024-04-22022 April 2024 Integrated Inspection Report 05000321/2024001 and 05000366/2024001 NL-24-0026, Application to Revise Technical Specifications Surveillance Requirements to Increase Safety/Relief Valves Setpoint2024-04-19019 April 2024 Application to Revise Technical Specifications Surveillance Requirements to Increase Safety/Relief Valves Setpoint NL-24-0144, Primary Containment Penetration Exceeded Maximum Allowable Primary Containment Leakage Rate (La)2024-04-0909 April 2024 Primary Containment Penetration Exceeded Maximum Allowable Primary Containment Leakage Rate (La) NL-24-0115, Response to Request for Additional Information Exemption Requests for Physical.2024-04-0404 April 2024 Response to Request for Additional Information Exemption Requests for Physical. NL-24-0116, Nuclear Property Insurance Coverage as of April 1, 2024 and Licensee Guarantees of Payment of Deferred.2024-03-29029 March 2024 Nuclear Property Insurance Coverage as of April 1, 2024 and Licensee Guarantees of Payment of Deferred. NL-24-0062, Report of Changes to Emergency Plan and Summary of 50.54(q) Analysis2024-03-12012 March 2024 Report of Changes to Emergency Plan and Summary of 50.54(q) Analysis NL-24-0089, Correction of Technical Specification Omission2024-03-0909 March 2024 Correction of Technical Specification Omission ML24069A0012024-03-0909 March 2024 – Correction of Amendment No. 266 Regarding License Amendment Request Regarding Relocation of Specific Surveillance Frequencies to a Licensee-Controlled Program (TSTF-425, Revision 3) ML24047A0362024-03-0404 March 2024 Response to Hatch and Vogtle FOF Dates Change Request (2025) NL-24-0061, Cycle 32 Core Operating Limits Report Version 12024-03-0101 March 2024 Cycle 32 Core Operating Limits Report Version 1 IR 05000321/20230062024-02-28028 February 2024 Annual Assessment Letter Edwin I. Hatch Nuclear Plant Units 1 and 2 - Nrc Inspection Report 05000321/2023006 and 05000366/2023006 NL-24-0067, 10 CFR 72.48(d)(2) Biennial Report2024-02-26026 February 2024 10 CFR 72.48(d)(2) Biennial Report NL-24-0051, License Amendment Request to Revise Renewed Facility Operating Licenses to Adopt an Alternative Seismic Method for Categorization of Structures, Systems, and Components2024-02-20020 February 2024 License Amendment Request to Revise Renewed Facility Operating Licenses to Adopt an Alternative Seismic Method for Categorization of Structures, Systems, and Components NL-24-0042, Response to Request for Additional Information Exemption Requests for Physical Barriers2024-02-13013 February 2024 Response to Request for Additional Information Exemption Requests for Physical Barriers NL-24-0033, Response to Question for Withholding Information from Public Disclosure Exemption Requests for Physical Barriers2024-02-0505 February 2024 Response to Question for Withholding Information from Public Disclosure Exemption Requests for Physical Barriers IR 05000321/20230042024-01-31031 January 2024 Integrated Inspection Report 05000321/2023004 and 05000366/2023004 ML24012A0652024-01-30030 January 2024 Exemption from Select Requirements of 10 CFR Part 73 (Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting) NL-24-0014, Revised Response to Request for Additional Information Regarding License Amendment Request to Relax the Required Number of Fully Tensioned Reactor Pressure Vessel Head Closure Studs in Technical.2024-01-30030 January 2024 Revised Response to Request for Additional Information Regarding License Amendment Request to Relax the Required Number of Fully Tensioned Reactor Pressure Vessel Head Closure Studs in Technical. IR 05000321/20233012024-01-17017 January 2024 – NRC Operator License Examination Report 05000321/2023301 and 05000366/2023301 2024-09-09
[Table view] Category:Safety Evaluation
MONTHYEARML23202A1122023-08-0202 August 2023 Units, 1 and 2; and Vogtle Units 1 and 2 - Request to Use a Provision of a Later Edition of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section XI ML23034A2462023-02-21021 February 2023 Audit Summary for License Amendment Request to Relax Required Number of Fully Tensioned Reactor Pressure Vessel Head Closure Studs ML22363A3932023-02-15015 February 2023 Issuance of Amendments Nos. 321 and 266, Regarding License Amendment Request to Revise the (National Fire Protection Association) NFPA-805 Fire Protection Program ML22346A1482023-02-0909 February 2023 Issuance of Amendments 320 and 265, Regarding LAR to Revise Technical Specifications to Adopt TSTF-208 and Administrative Correction for Duplicate Technical Specifications 3.4.10 ML22297A1462022-12-22022 December 2022 Issuance of Amendments Nos. 319 and 264, Regarding Revision to Technical Specifications to Adopt Risk-Informed Completion Times TSTF 505, Revision 2, Provide Risk-Informed Extended Completion Times RITS ML22293A0302022-11-0707 November 2022 Amendments 318 & 263 Issuance, Regarding LAR to Adopt TSTF-227, Revision to EOC-RPT Pump Actions, and TSTF-297, ATWS-RPT (EPID L-2021-LLA- 0227) ML22192A1172022-09-0202 September 2022 Issuance of Amendments Nos. 317 & 262, Regarding License Amendment Request to Revise Technical Specifications to Adopt TSTF-207-A, Completion Time for Restoration of Various Excessive Leakage Rates ML22192A1992022-08-19019 August 2022 Issuance of Amendments Nos. 316 and 261, Regarding Request to Adopt TSTF-580, Provide Exception from Entering Mode 4 with No Operable RHR Shutdown Cooling ML22101A0942022-05-20020 May 2022 Issuance of Amendments Nos. 315 and 260, Regarding Request to Eliminate Automatic Main Steam Line Isolation on High Turbine Building Area Temperature ML21349A5182022-02-0202 February 2022 Issuance of Amendments Regarding Revision to Technical Specifications to Adopt TSTF-554, Revise RCS Leakage ML21270A0862021-11-18018 November 2021 Issuance of Amendments Regarding Revision to Technical Specifications 5.7, High Radiation, Administrative Controls ML21264A6442021-09-24024 September 2021 Issuance of Amendment to Revise Technical Specification 3.7.2, Plant Service Water (Psw) System and Ultimate Heat Sink (UHS) (EPID L-2021-LLA-0164) (Emergency Circumstances) ML21217A0912021-09-21021 September 2021 SNC Fleet, Issuance of Amendments Regarding Revision to Emergency Plan to Change Staffing and Extend Staff Augmentation Times for Emergency Response Organization Positions ML21167A3152021-07-30030 July 2021 Issuance of Amendments Regarding Revision to Technical Specifications to Adopt TSTF-541, Rev.2, Add Exceptions to Surveillance Requirements for Valves & Dampers Locked in Actuated Position ML21161A2012021-06-22022 June 2021 Associated Independent Spent Fuel Storage Facilities - Reduction in Commitment to the Quality ML21109A3592021-04-22022 April 2021 Issuance of Amendment No. 254, Regarding Revision to Technical Specifications for One-Time Extension of Completion Times Related to Residual Heat Removal System (Emergency Circumstances) ML20294A0762020-12-0707 December 2020 Issuance of Amendments Nos. 308 and 253, Regarding Application to Revise Technical Specifications to Adopt TSTF-582, Reactor Pressure Vessel Water Inventory Control Enhancements ML20254A0752020-09-18018 September 2020 Safety Evaluation by the Office of Nuclear Reactor Regulation Related to Amendment No. 307 to Facility Operating License No. DPR-57 and Amendment No. 252 to Facility Operating License No. NPF-5 ML20202A0052020-09-15015 September 2020 Issuance of Amendments Nos. 306 and 251, Regarding the Application to Revise Technical Specifications to Adopt TSTF-568, Revise Appliciability of BWR/4 TS 3.6.2.5 and TS 3.6.3.2 ML20077J7042020-06-26026 June 2020 Issuance of Amendment Nos. 305 and 250, Regarding Adoption of 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems, and Components for Nuclear Power Reactors ML20066F5922020-06-11011 June 2020 Issuance of Amendments Nos. 304 and 249, Regarding License Amendment Request to Adopt NFPA-805 Performance Based Standard for Fire Protection for Light Water Reactor Electric Generating Plants (2001 Edition) ML20143A2332020-06-0303 June 2020 Relief Request for Deferral of ASME Boiler and Pressure Vessel Code, Section XI, Required Summary Report Submittal (EPID L-2020-LLR-0074 (COVID-19)) ML20034E8942020-02-11011 February 2020 Relief Request Gen-ISI-ALT-2019-01 for Proposed Alternative to Use of ASME Code Case N-831-1, Ultrasonic Examination in Lieu of Radiography for Welds in Ferritic or Austenitic Pipe Section XI, Division 1 ML19337C3222020-01-29029 January 2020 Issuance of Amendments Revision to Technical Specifications to Adopt TSTF-563 ML19239A2442019-11-19019 November 2019 Issuance of Amendments Regarding Revision to Technical Specification Requirements During Handling Irradiated Fuel and Core Alterations ML19267A0232019-11-13013 November 2019 Issuance of Amendments the Revision to Technical Specifications to Adopt TSTF-566, Revise Actions for Inoperable (Residual Heat Removal) RHR Shutdown Cooling Subsystems, Using Consolidated Line Item Improvement Process ML19212A0542019-09-20020 September 2019 Issuance of Amendments 299 and 244 Regarding Revision to Technical Specifications to Adopt Tstf-564, Safety Limit (Minimum Critical Power Ratio) MCPR ML19198A1042019-09-0404 September 2019 Issuance of Amendments Regarding Revision to Technical Specification 3.6.4.1 - Secondary Containment ML19177A1662019-07-0808 July 2019 Edwin Hatch Unit Nos. 1 and 2, Issuance of Amendments Regarding License Amendment Request to Correct Non-Conservative Technical Specification Allowable Values for the Condensate Storage Tank Low Level Transfer Function ML19091A2912019-04-30030 April 2019 Issuance of Amendments 296 and 241 to Revise Technical Specifications 3.6.2.5, Condition C, Residual Heat Removal Drywell Spray End State ML19064A7742019-04-26026 April 2019 Issuance of Amendments Regarding License Amendment Request to Revise Technical Specification 5.2.2.g and Update Emergency Plan Minimum on Shift Staff Tables ML19044A5552019-04-0303 April 2019 Safety Evaluation Regarding Implementation of Hardened Containment Vents Capable of Operation Under Severe Accident Conditions Related to Order EA-13-109 ML19064A0872019-03-0808 March 2019 Proposed Inservice Inspection Alternative HNP-ISI-ALT-05-08 ML19053A0932019-02-22022 February 2019 Issuance of Amendments to Revise Technical Specification 3.8.1, AC Sources - Operating (EPID L-2019-LLA-0026) (Emergency Circumstances) ML19035A5502019-02-0606 February 2019 Relief Request HNP ISI RR 05-02 Regarding Reactor Pressure Vessel Head Stud Inservice Inspection Requirements ML19010A0092019-01-28028 January 2019 Issuance of Amendments to Revise Technical Specification 3.3.8.1, Loss of Power (LOP) Instrumentation ML19011A0102019-01-22022 January 2019 Proposed Alternative HNP-ISI-ALT-05-04 for the Implementation of BWRVIP Guidelines ML18320A0572018-11-30030 November 2018 Plant, Units 1 and 2 - Proposed Inservice Inspection Alternative GEN-ISI-ALT-2017-03, Code Case N-513-4 for Moderate Pressure ML18289A6192018-10-18018 October 2018 Proposed Inservice Inspection Alternative HNP-ISI-ALT-05-07 ML18222A2962018-08-29029 August 2018 Issuance of Amendments to Revise Technical Specification 3.7.7, ECCS - Operating (CAC Nos. MF9997 and MF9998; EPID L-2017-LLA-0263) ML18183A0732018-07-26026 July 2018 Unites 1, 2, 3, and 4; and Edwin I. Hatch Nuclear Plant, Unit Nos. 1 and 2(CAC Nos. MG0188, MG0189, MG0191, MG0192, MG0193, MG0194, and MG0195; EPID L-2017-LLA-0293) ML18163A1602018-06-15015 June 2018 Proposed Alternative RR-V-11, Extension of Main Steam Safety Relief Valve Test Interval ML18123A3682018-05-31031 May 2018 Issuance of Amendments to Adopt TSTF-542, RPV Water Inventory Control (CAC Nos. MF9662 and MF9663; EPID L-2017-LLA-0215) ML18102B0162018-04-16016 April 2018 Proposed Inservice Inspection Alternative HNP-ISI-ALT-05-05 (CAC Nos. MF9812 and MF9813; EPID L-2017-LLR-0053) ML18022A1072018-01-25025 January 2018 Inservice Inspection Alternative GEN-ISI-ALT-2017-02, Version 1.0, Regarding the Use of ASME Code Case N-789-1 (CAC Nos. MF9942, MF9943, MF9944, and MF9945; EPID L-2017-LLR-0059) ML17355A4402018-01-22022 January 2018 Issuance of Amendments to Revise TS 3.6.4.1, Secondary Containment (CAC Nos. MF9590 and MF9591; EPID L-2017-LLA-0216) ML17271A3072017-11-30030 November 2017 Issuance of Amendments to Revise Actions of TS 5.5.12, Primary Containment Leakage Rate Testing Program ML17279A0452017-10-26026 October 2017 Relief Requests ISI-RR-13, -14, -18, -19, -23, and -24 for Relief from Inservice Inspection Requirements ML17268A0442017-10-20020 October 2017 Relief Requests ISI RR 16, ISI-RR-17, ISI-44-21, and ISI-RR-22 for Relief from Inservice Inspection Requirements ML17208A2312017-08-29029 August 2017 Issuance of Amendments Regarding the Adoption of TSTF 500, DC Electrical Rewrite - Update to TSTF 360 2023-08-02
[Table view] |
Text
September 10, 2007 Mr. Dennis R. Madison Vice President - Hatch Edwin I. Hatch Nuclear Plant 11028 Hatch Parkway North Baxley, GA 31513
SUBJECT:
EDWIN I. HATCH NUCLEAR PLANT, UNIT NOS. 1 AND 2, ONE-TIME ONLY PROPOSED CONTINGENCY PLAN FOR USE DURING THE REPLACEMENT OF THE EXISTING MAIN STACK HIGH RANGE RADIATION MONITORS (TAC NOS. MD6129, MD6130)
Dear Mr. Madison:
By letter dated February 20, 2007, Southern Nuclear Operating Company (SNC), requested prior review by the Nuclear Regulatory Commission (NRC) staff of a proposed contingency plan to allow for a 6-day out-of-service time for the replacement of the main stack high range radiation monitors (MSHRMs) for the Edwin I. Hatch Nuclear Plant, Units 1 and 2 (HNP). SNC proposes to replace the existing MSHRMs at HNP with new functionally equivalent monitors. During this changeover, neither the existing nor new MSHRMs would be available. As a result, high range radiation monitoring of this potential accident release path would be unavailable for a period of about 7 days. SNC determined that this condition would decrease the effectiveness of the approved HNP Emergency Plan and applied for approval by the NRC staff. In its letter, SNC identified several contingencies for assessing releases should an accident occur during the period the MSHRMs are out of service. The NRC staff has completed a review of the proposed contingency plan and supporting documentation. The NRC staff has concluded that the proposed contingency plan maintains the effectiveness of the applicable emergency plan, and continues to meet the standards of Title 10 of the Code of Federal Regulations, Part 50, Section 50.47(b) and the requirements of Appendix E to Part 50. The NRC staffs conclusion is predicated to a large degree on the relatively short duration of the outage and the staffs expectation that SNC will make a best effort to minimize the duration of the outage to the extent practicable. The basis for the NRC staffs conclusion is contained in the enclosure.
Sincerely,
/RA/
Robert E. Martin, Senior Project Manager Plant Licensing Branch II-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-321 and 50-366
Enclosure:
Safety Evaluation cc w/encl: See next page
September 10, 2007 Mr. Dennis R. Madison Vice President - Hatch Edwin I. Hatch Nuclear Plant 11028 Hatch Parkway North Baxley, GA 31513
SUBJECT:
EDWIN I. HATCH NUCLEAR PLANT, UNIT NOS. 1 AND 2, ONE-TIME ONLY PROPOSED CONTINGENCY PLAN FOR USE DURING THE REPLACEMENT OF THE EXISTING MAIN STACK HIGH RANGE RADIATION MONITORS (TAC NOS. MD6129, MD6130)
Dear Mr. Madison:
By letter dated February 20, 2007, Southern Nuclear Operating Company (SNC), requested prior review by the Nuclear Regulatory Commission (NRC) staff of a proposed contingency plan to allow for a 6-day out-of-service time for the replacement of the main stack high range radiation monitors (MSHRMs) for the Edwin I. Hatch Nuclear Plant, Units 1 and 2 (HNP). SNC proposes to replace the existing MSHRMs at HNP with new functionally equivalent monitors. During this changeover, neither the existing nor new MSHRMs would be available. As a result, high range radiation monitoring of this potential accident release path would be unavailable for a period of about 7 days. SNC determined that this condition would decrease the effectiveness of the approved HNP Emergency Plan and applied for approval by the NRC staff. In its letter, SNC identified several contingencies for assessing releases should an accident occur during the period the MSHRMs are out of service. The NRC staff has completed a review of the proposed contingency plan and supporting documentation. The NRC staff has concluded that the proposed contingency plan maintains the effectiveness of the applicable emergency plan, and continues to meet the standards of Title 10 of the Code of Federal Regulations, Part 50, Section 50.47(b) and the requirements of Appendix E to Part 50. The NRC staffs conclusion is predicated to a large degree on the relatively short duration of the outage and the staffs expectation that SNC will make a best effort to minimize the duration of the outage to the extent practicable. The basis for the NRC staffs conclusion is contained in the enclosure.
Sincerely,
/RA/
Robert E. Martin, Senior Project Manager Plant Licensing Branch II-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-321 and 50-366
Enclosure:
Safety Evaluation cc w/encls: See next page DISTRIBUTION: Public RidsAcrsAcnwMailCenter RidsOgcRp LPL2-1 R/F SLavie, NSIR MNorris, NSIR RidsNrrDorlLpl2-1 (EMarinos) RidsNrrLAMO=Brien (hard copy) RidsNrrDorlDpr RidsNrrPMRMartin (hard copy) RidsRgn2Mail Center (SShaeffer)
Accession No. ML072470596 OFFICE NRR/LPL2-1/PM NRR/LPL2-1/LA NSIR/LIB/BC NRR/LPL2-1/BC NAME RMartin MO=Brien By memo dated EMarinos 08/29/2007 DATE 9/6/07 9/6/07 9/10/07 OFFICIAL RECORD COPY
SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION RELATED TO ONE-TIME ONLY PROPOSED CONTINGENCY PLAN FOR USE DURING THE REPLACEMENT OF THE EXISTING MAIN STACK HIGH RANGE RADIATION MONITORS SOUTHERN NUCLEAR OPERATING COMPANY, INC.
EDWIN I. HATCH NUCLEAR PLANT, UNIT NOS. 1 AND 2 DOCKET NOS. 50-321 AND 50-366
1.0 INTRODUCTION
By application dated February 20, 2007, (Agencywide Documents Access and Management System (ADAMS) Accession No. ML070510429), Southern Nuclear Operating Company, Inc.
(SNC, the licensee), requested prior review by the Nuclear Regulatory Commission (NRC) staff (staff) of a proposed contingency plan to allow for a 6-day out-of-service time for the replacement of the main stack high range radiation monitors (MSHRMs) for the Edwin I. Hatch Nuclear Plant, Units 1 and 2 (HNP). SNC proposes to replace the existing MSHRMs at HNP with new functionally equivalent monitors. During this changeover, neither the existing nor new MSHRMs would be available. As a result, high range radiation monitoring of this potential accident release path would be unavailable for a period of about 7 days. SNC determined that this condition would decrease the effectiveness of the approved HNP Emergency Plan and applied for approval by the NRC staff. In its letter, SNC identified several contingencies for assessing releases should an accident occur during the period the MSHRMs are out of service.
2.0 REGULATORY EVALUATION
The NRC staff reviewed the proposed revision against the following regulations and guidance.
2.1 Regulations Paragraph (a)(1) to Title 10 of the Code of Federal Regulations (10 CFR), Part 50, Section 50.47, Emergency Plans, states that no operating license for a nuclear power reactor will be issued unless a finding is made by the NRC that the state of onsite and offsite emergency preparedness provides reasonable assurance that adequate protective measures can and will be taken in the event of a radiological emergency. Section 50.47 also establishes standards that must be met by the onsite and offsite emergency response plans for NRC staff to make a positive finding that there is reasonable assurance that adequate protective measures can and will be taken in the
event of a radiological emergency. One of these standards, Section 50.47(b)(9), stipulates that adequate methods, systems, and equipment for assessing and monitoring actual or potential offsite consequences of a radiological emergency condition are in use.Section IV.E to Appendix E, Emergency Planning and Preparedness for Production and Utilization Facilities, of 10 CFR Part 50 provides that emergency facilities and equipment have adequate provisions for determining the magnitude of and for continuously assessing the impact of the release of radioactive materials to the environment.
2.2 Guidance
- Appendix 1 to NUREG-0654/FEMA-REP-1, Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants (November 1980),
3.0 TECHNICAL EVALUATION
This evaluation is based on information provided in SNCs letter of February 20, 2007, including the attached 10 CFR 50.54(q) evaluation. SNC identified several contingencies for assessing releases should an accident occur during the period the MSHRMs are out of service. These included:
- 1. The main stack normal range monitors will remain in service and would be used as long as they remained on scale.
- 2. All monitors in the reactor building vents will remain in service during this period.
- 3. The drywell wide range monitors and the post-loss-of-coolant accident (LOCA) monitors will be available during this period and could be used for accident sequences, for which the releases would be monitored by these monitors.
- 4. Field monitoring teams would be dispatched in the event that the release exceeds the range of the normal range monitors.
- 5. The HNP dose assessment software is capable of performing assessments using readings from other in-plant monitors or the field monitoring results.
- 6. The HNP emergency action level scheme includes thresholds based on the various radiological effluent monitor indications, field monitoring team results, and various in-plant radiation monitors.
Although these contingency methods are available, the SNC 10 CFR 50.54(q) evaluation stated that the use of these contingency methods would not be effective as the MSHRMs since delays in emergency classifications, dose assessments, and protective action recommendations could occur. In considering whether the proposed outage would reduce the effectiveness of the HNP Emergency Plan, the staff considered the impact on the ability to perform the planning standard functions of onsite emergency response plans; Section 50.47(b)(4), emergency classification; Section 50.47(b)(9), assessment; and Section 50.47(b)(10), protective actions.
3.1 Emergency Classification With regard to emergency classification, the emergency action level (EAL) thresholds based on the MSHRMs would be unavailable for use in classification. Although effluent radiation monitor alarms may often be the first indication of an off-normal release or radioactive material to the environment at the unusual event and alert classification levels, this is not the case at the higher emergency classifications. Environmental releases of a magnitude that would be monitored by the unavailable MSHRMs are associated with events that involve core damage. There are several EAL thresholds associated with precursors to core damage (e.g., plant conditions that could lead to core damage if not corrected) or those that are associated with indications that core damage has occurred (e.g., drywell high range radiation monitors, in containment hydrogen monitors).
These other EAL thresholds would likely provide the basis for emergency declarations before the MSHRMs would have been on scale and well before there would be environmental radiation levels for the field teams to measure offsite. Also, the insights from severe accident analyses show that the more substantial environmental releases will occur via release pathways that are not monitored pathways. Since core damage would be identified by various precursor conditions, it is likely that the initial emergency declaration would not be a general emergency, and that the declaration would occur prior to the onset of a substantial release to the environment. As such, it is also likely that the emergency plan would be activated prior to the need to rely on the MSHRMs, and that the emergency response organization, including field monitoring teams would be available when a release comparable to the MSHRM range became imminent. Based on the above, the staff concludes that it is unlikely that the unavailability of the MSHRMs would, in and of themselves, preclude appropriate emergency classification and declaration, and subsequent protective action recommendations during the planned monitor outage.
3.2 Assessment With regard to assessment, including dose assessment, the MSHRMs are utilized for performing dose projections. These dose projections provide input to emergency classification decisions discussed above and protective action recommendations discussed below. The ability to perform dose assessments is considered to be an important emergency response function. However, as identified in the SNC letter and analysis, the HNP dose assessment capability can be driven by inputs other than the MSHRMs. Nonetheless, as SNC stated, the unavailability of these high range radiation monitors would limit the ability to directly monitor main stack release with magnitudes comparable to site area or general emergencies without incurring delay (e.g.,
dispatching field monitoring teams.) Such events involve substantial core damage which could be monitored by increased readings on the drywell wide range and other post-LOCA monitors. As was noted above, dose projections based on effluent monitor readings are possible only if the release is in progress and the release is via a monitored pathway. The insights from severe accident analyses show that the more substantial environmental releases will occur via release
pathways that are not monitored pathways. Assessment of plant conditions begins with the lowest emergency classification declared and continues as the plant conditions deteriorate further and the emergency classification is escalated. Except in the unlikely occurrence of an event that progresses immediately to a general emergency, the results of the ongoing assessments at lower classifications will drive other response actions, including the dispatch of field monitor teams or the alternate determination of release source terms, before the release magnitude would cause the MSHRMs to be on scale had they been available. Based on the above, the staff concludes that it is unlikely that the unavailability of the MSHRMs would, in of themselves, preclude performance of dose assessments during the planned monitor outage.
3.3 Protective Action Recommendations Finally, with regard to the capability to provide appropriate protective action recommendations (PARs) to offsite officials, the unavailability of the MSHRMs only affects PARs based on dose assessment results. PARs based on plant condition, including the default PAR associated with a general emergency, are unaffected by the monitor outage. A release of a magnitude warranting offsite protective actions is unlikely to occur in the absence of a degradation of the reactor coolant system, fuel, and containment fission product barriersplant conditions that could be identified by several other EAL thresholds. These thresholds would likely be met prior to the onset of the radioactivity release to the environment. Thus, at a minimum, the default PAR associated with a general emergency could be relayed to offsite officials. Extension of the default PAR might be based on dose assessment and/or field monitoring results and the delay in obtaining these data could impact the extension of the PARs. However, the staff concluded above that it would be unlikely that the unavailability of the MSHRMs would, in and of themselves, preclude performance of dose assessments during the planned monitor outage. Accordingly, based on the above, the staff concludes that it is unlikely that the unavailability of the MSHRMs would, in and of themselves, preclude protective action recommendations during the planned monitor outage.
4.0 CONCLUSION
The staff performed a technical and regulatory review of the proposed outage of the MSHRMs at HNP. The staff has determined, based on the considerations above, that: (1) there is reasonable assurance that the health and safety of the public will not be endangered by the planned monitor outage, (2) such activities will be conducted in compliance with the Commissions regulations, and (3) the proposed changes will not be inimical to the common defense and security or to the health and safety of the public. The staffs conclusion is predicated to a large degree on the relatively short duration of the outage and the staff expectation that SNC will make a best effort to minimize the duration of the outage to the extent practicable. This evaluation is applicable for a one-time only replacement of the existing MSHRMs.
5.0 REFERENCES
- 1. Letter from SNC to the NRC dated February 20, 2007, Replacement of Main Stack High Range Accident Radiation Monitors, ADAMS Accession No. ML070510429.
- 2. Emergency Planning and Preparedness for Nuclear Power Reactors, Regulatory Guide 1.101, Revision 4. ADAMS Accession No. ML032020276.
- 3. NUREG-0654, Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants, ADAMS Accession No. ML040420012.
- 4. NRC Information Notice 2005-19, Effect of Plant Configuration Changes on the Emergency Plan.
Principal Contributor: Michael Norris, NSIR/DPR Date: September 10, 2007
Edwin I. Hatch Nuclear Plant, Units 1 & 2 cc:
Mr. Dennis R. Madison Arthur H. Domby, Esq.
Vice President - Hatch Troutman Sanders Edwin I. Hatch Nuclear Nations Bank Plaza 11028 Hatch Parkway North 600 Peachtree St, NE, Suite 5200 Baxley, GA 31513 Atlanta, GA 30308-2216 Laurence Bergen Chairman Oglethorpe Power Corporation Appling County Commissioners 2100 E. Exchange Place County Courthouse P.O. Box 1349 Baxley, GA 31513 Tucker, GA 30085-1349 Mr. Jeffrey T. Gasser Mr. R. D. Baker Executive Vice President Manager - Licensing Southern Nuclear Operating Company, Inc.
Southern Nuclear Operating Company, Inc. P.O. Box 1295 P.O. Box 1295 Birmingham, AL 35201-1295 Birmingham, AL 35201-1295 Mr. K. Rosanski Resident Inspector Resident Manager Plant Hatch Oglethorpe Power Corporation 11030 Hatch Parkway N. Edwin I. Hatch Nuclear Plant Baxley, GA 31531 P.O. Box 2010 Baxley, GA 31515 Harold Reheis, Director Department of Natural Resources 205 Butler Street, SE., Suite 1252 Atlanta, GA 30334 Steven M. Jackson Senior Engineer - Power Supply Municipal Electric Authority of Georgia 1470 Riveredge Parkway, NW Atlanta, GA 30328-4684 Mr. Reece McAlister Executive Secretary Georgia Public Service Commission 244 Washington St., SW Atlanta, GA 30334