MONTHYEARML0700303222007-01-0909 January 2007 Request for Additional Information License Amendment Request for Spent Fuel Pool Storage Capacity Project stage: RAI ML0635407392007-01-12012 January 2007 Individual Notice of Consideration of Issuance of Amendment to Facility Operating License and Opportunity for a Hearing in Conjunction with the Expansion of Spent Fuel Pool Storage Capacity Project stage: Other ML0635407342007-01-12012 January 2007 Letter to License Individual Notice of Consideration of Issuance of Amendment to Facility Operating License and Opportunity for a Hearing in Conjunction with the Expansion of Spent Fuel Pool Storage Capacity Project stage: Other ML0704502422007-02-27027 February 2007 Withholding from Public Disclosure, Table 4-1 of Hi (Holtec International)-2043224, MD3349 Project stage: Other ML0704502372007-02-27027 February 2007 Request for Withholding Information from Public Disclosure - Holtec International Project stage: Withholding Request Acceptance ML0704003662007-02-27027 February 2007 Request for Withholding Information from Public Disclosure - Global Nuclear Fuel - Americas, LLC 1/24/07 Affidavit Project stage: Withholding Request Acceptance ML0705902302007-03-0505 March 2007 Request for Additional Information - License Amendment Request Onsite Spent Fuel Storage Expansion Project stage: RAI ML0708201972007-03-15015 March 2007 H. Floyd Gilzow, State of Missouri Department of Natural Resources, Letter to C. Lyon, NRC, Cooper Nuclear Station - Request for Withholding Information from Public Disclosure Project stage: Withholding Request NLS2007012, Non-Proprietary Version of Response to Request for Additional Information Regarding License Amendment Request for Onsite Spent Fuel Storage Expansion2007-04-17017 April 2007 Non-Proprietary Version of Response to Request for Additional Information Regarding License Amendment Request for Onsite Spent Fuel Storage Expansion Project stage: Response to RAI NLS2007040, Affidavit Requesting Withholding from Public Disclosure Regarding Response to Request for Additional Information to Support NRC Review of License Amendment Request to Increase Capacity of Onsite Spent Fuel Storage at Cooper2007-05-0404 May 2007 Affidavit Requesting Withholding from Public Disclosure Regarding Response to Request for Additional Information to Support NRC Review of License Amendment Request to Increase Capacity of Onsite Spent Fuel Storage at Cooper Project stage: Response to RAI ML0714903152007-05-23023 May 2007 Response to Informal RAI Regarding Spent Fuel Pool Expansion Amendment Request Project stage: Other NLS2007056, Revised Page from Holtec International Non-Proprietary Report2007-07-26026 July 2007 Revised Page from Holtec International Non-Proprietary Report Project stage: Request ML0721300052007-08-28028 August 2007 Letter and Federal Register Notice of Environmental Assessment and Finding of No Significant Impact Onsite Spent Fuel Storage Expansion Project stage: Other ML0721300232007-09-0606 September 2007 License Amendment, Issuance of Amendment No. 227 Onsite Spent Fuel Storage Expansion Project stage: Approval 2007-04-17
[Table View] |
|
---|
Category:Letter type:NLS
MONTHYEARNLS2024006, Response to Nuclear Regulatory Commission'S Request for Additional Information for Relief Request RC3-022024-01-25025 January 2024 Response to Nuclear Regulatory Commission'S Request for Additional Information for Relief Request RC3-02 NLS2024007, Emergency Plan Implementing Procedure 5.7.1, Revision 732024-01-16016 January 2024 Emergency Plan Implementing Procedure 5.7.1, Revision 73 NLS2024003, 30 Day Report - Unauthorized Disassembly of Liquid Scintillation Detector2024-01-15015 January 2024 30 Day Report - Unauthorized Disassembly of Liquid Scintillation Detector NLS2024004, Annual Report of Changes and Errors in Emergency Core Cooling System Evaluation Models for 20232024-01-10010 January 2024 Annual Report of Changes and Errors in Emergency Core Cooling System Evaluation Models for 2023 NLS2023053, ISFSI, Supplement to Exemption Request from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation2023-11-30030 November 2023 ISFSI, Supplement to Exemption Request from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation NLS2023050, Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation2023-11-22022 November 2023 Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation NLS2023045, Application to Revise Technical Specifications to Adopt TSTF-374, Revision to Diesel Fuel Oil Testing Program2023-11-15015 November 2023 Application to Revise Technical Specifications to Adopt TSTF-374, Revision to Diesel Fuel Oil Testing Program NLS2023051, Response to Nuclear Regulatory Commission Request for Additional Information Regarding Application to Revise Technical Specifications to Adopt TSTF-551, Revise Secondary Containment Surveillance Requirements2023-10-10010 October 2023 Response to Nuclear Regulatory Commission Request for Additional Information Regarding Application to Revise Technical Specifications to Adopt TSTF-551, Revise Secondary Containment Surveillance Requirements NLS2023049, 10 CFR Part 21 Report Regarding HGA Relays2023-09-0606 September 2023 10 CFR Part 21 Report Regarding HGA Relays NLS2023029, License Amendment Request to Revise Technical Specifications to Support Inspection of Diesel Fuel Oil Storage Tanks2023-09-0606 September 2023 License Amendment Request to Revise Technical Specifications to Support Inspection of Diesel Fuel Oil Storage Tanks NLS2023047, Licensee Guarantees of Payment of Deferred Premiums2023-07-26026 July 2023 Licensee Guarantees of Payment of Deferred Premiums NLS2023033, 10 CFR 50.55a Relief Request RC3-022023-06-27027 June 2023 10 CFR 50.55a Relief Request RC3-02 NLS2023039, Preparation and Scheduling of Operator Licensing Examinations2023-06-0101 June 2023 Preparation and Scheduling of Operator Licensing Examinations NLS2023038, Nebraska Public Power District 2022 Financial Report2023-05-22022 May 2023 Nebraska Public Power District 2022 Financial Report NLS2023031, Annual Radiological Environmental Report2023-05-11011 May 2023 Annual Radiological Environmental Report NLS2023017, Application to Revise Technical Specifications to Adopt TSTF-551, Revise Secondary Containment Surveillance Requirements2023-05-0303 May 2023 Application to Revise Technical Specifications to Adopt TSTF-551, Revise Secondary Containment Surveillance Requirements NLS2023018, Application to Revise Technical Specifications to Adopt TSTF-580, Provide Exception from Entering Mode 4 with No Operable RHR Shutdown Cooling2023-05-0303 May 2023 Application to Revise Technical Specifications to Adopt TSTF-580, Provide Exception from Entering Mode 4 with No Operable RHR Shutdown Cooling NLS2023030, Annual Radioactive Effluent Release Report2023-04-27027 April 2023 Annual Radioactive Effluent Release Report NLS2023007, Technical Specification Bases Changes2023-04-17017 April 2023 Technical Specification Bases Changes NLS2023027, Annual Report of Individual Exposure Monitoring2023-04-13013 April 2023 Annual Report of Individual Exposure Monitoring NLS2023021, Quality Assurance Program Changes2023-04-10010 April 2023 Quality Assurance Program Changes NLS2023020, Decommissioning Funding2023-03-29029 March 2023 Decommissioning Funding NLS2023019, Property Insurance Coverage2023-03-23023 March 2023 Property Insurance Coverage NLS2023010, Inservice Inspection OAR-1 Owner'S Activity Report for Cooper Nuclear Station2023-02-0909 February 2023 Inservice Inspection OAR-1 Owner'S Activity Report for Cooper Nuclear Station NLS2023005, Annual Report of Changes and Errors in Emergency Core Cooling System Evaluation Models for 20222023-01-19019 January 2023 Annual Report of Changes and Errors in Emergency Core Cooling System Evaluation Models for 2022 NLS2022054, Preparation and Scheduling of Operator Licensing Examinations2023-01-0505 January 2023 Preparation and Scheduling of Operator Licensing Examinations NLS2022055, Emergency Plan, Revision 812023-01-0404 January 2023 Emergency Plan, Revision 81 NLS2022053, CNS-2022-11 Post Exam Submittal2022-11-22022 November 2022 CNS-2022-11 Post Exam Submittal NLS2022050, Notification of Revision to Cooper Nuclear Station Emergency Response Data System Data Point Library2022-11-0909 November 2022 Notification of Revision to Cooper Nuclear Station Emergency Response Data System Data Point Library NLS2022048, Management Change and Correspondence Update2022-11-0101 November 2022 Management Change and Correspondence Update NLS2022047, Core Operating Limits Report, Cycle 33, Revision 02022-10-14014 October 2022 Core Operating Limits Report, Cycle 33, Revision 0 NLS2022042, 10 CFR 50.59(d)(2) and 10 CFR 72.48(d)(2) Summary Report2022-10-0707 October 2022 10 CFR 50.59(d)(2) and 10 CFR 72.48(d)(2) Summary Report NLS2022037, Emergency Plan, Revision 80, Summary of 50.54(q) Analyses2022-08-18018 August 2022 Emergency Plan, Revision 80, Summary of 50.54(q) Analyses NLS2022035, Evacuation Time Estimate Report for Cooper Nuclear Station2022-08-16016 August 2022 Evacuation Time Estimate Report for Cooper Nuclear Station NLS2022031, Licensee Guarantees of Payment of Deferred Premiums2022-07-19019 July 2022 Licensee Guarantees of Payment of Deferred Premiums NLS2022005, Application to Revise Technical Specifications to Adopt TSTF-554, Revision 1, Revise Reactor Coolant Leakage Requirements2022-06-16016 June 2022 Application to Revise Technical Specifications to Adopt TSTF-554, Revision 1, Revise Reactor Coolant Leakage Requirements NLS2022025, Nebraska Public Power District Letter (NLS2022010) to U.S. Nuclear Regulatory Commission Dated April 5, 2022, Annual Report of Individual Exposure Monitoring2022-06-0606 June 2022 Nebraska Public Power District Letter (NLS2022010) to U.S. Nuclear Regulatory Commission Dated April 5, 2022, Annual Report of Individual Exposure Monitoring NLS2022016, Annual Radiological Environmental Report2022-05-10010 May 2022 Annual Radiological Environmental Report NLS2022020, Nebraska Public Power District, Cooper Nuclear Station, 2021 Financial Report2022-05-0202 May 2022 Nebraska Public Power District, Cooper Nuclear Station, 2021 Financial Report NLS2022014, Annual Radioactive Effluent Release Report2022-04-27027 April 2022 Annual Radioactive Effluent Release Report NLS2022010, Annual Report of Individual Exposure Monitoring2022-04-0505 April 2022 Annual Report of Individual Exposure Monitoring NLS2022009, Property Insurance Coverage2022-03-23023 March 2022 Property Insurance Coverage NLS2022011, Preparation and Scheduling of Operator Licensing Examinations2022-03-18018 March 2022 Preparation and Scheduling of Operator Licensing Examinations NLS2022004, Response to Nuclear Regulatory Commission'S Request for Additional Information Regarding Relief Request RR5-01, Revision 12022-02-0707 February 2022 Response to Nuclear Regulatory Commission'S Request for Additional Information Regarding Relief Request RR5-01, Revision 1 NLS2022003, Annual Report of Changes and Errors in Emergency Core Cooling System Evaluation Models for 20212022-01-20020 January 2022 Annual Report of Changes and Errors in Emergency Core Cooling System Evaluation Models for 2021 NLS2021067, ISFSI - Independent Spent Fuel Storage Installation Decommissioning Funding Plan2021-12-16016 December 2021 ISFSI - Independent Spent Fuel Storage Installation Decommissioning Funding Plan NLS2021069, Withdrawal of Application to Revise Technical Specifications to Adopt TSTF-551, Revise Secondary Containment Surveillance Requirements2021-12-15015 December 2021 Withdrawal of Application to Revise Technical Specifications to Adopt TSTF-551, Revise Secondary Containment Surveillance Requirements NLS2021066, Response to Nuclear Regulatory Commission'S Request for Additional Information Regarding Alternative Request RI5-02, Revision 32021-12-10010 December 2021 Response to Nuclear Regulatory Commission'S Request for Additional Information Regarding Alternative Request RI5-02, Revision 3 NLS2021065, Clarification of Response to Nuclear Regulatory Commission'S Request for Additional Information for Alternative Request RS-012021-12-0606 December 2021 Clarification of Response to Nuclear Regulatory Commission'S Request for Additional Information for Alternative Request RS-01 NLS2021056, Application to Revise Technical Specifications to Adopt TSTF-551, Revise Secondary Containment Surveillance Requirements2021-11-16016 November 2021 Application to Revise Technical Specifications to Adopt TSTF-551, Revise Secondary Containment Surveillance Requirements 2024-01-25
[Table view] |
Text
H Nebraska Public Power District Ahivays there when you need us NLS2007056 July 26, 2007 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555-0001
Subject:
Revised Page from Holtec International Non-Proprietary Report Cooper Nuclear Station, Docket No. 50-298, DPR-46
Reference:
Letter from Stewart B. Minahan, Nebraska Public Power District, to U.S. Nuclear Regulatory Commission, dated October 17, 2006,
Subject:
License Amendment Request to Revise Technical Specification - Onsite Spent Fuel Storage Expansion
Dear Sir or Madam:
The purpose of this letter is to provide to the Nuclear Regulatory Commission (NRC) a revised page from a non-proprietary version of a report by Holtec hIternational (HI). By letter dated October 17, 2006 (Reference), the Nebraska Public Power District (NPPD) submitted a license amendment request (LAR) to revise Cooper Nuclear Station (CNS) Teclmical Specification (TS) 4.3.3 to increase the capacity of the spent fuel storage pool. HI report HI-2043224, entitled "Licensing Report on the Wet Fuel Storage Capacity Expansion at Cooper Nuclear Station," was submitted to the NRC as part of that LAR.
The NRC Project Manager for CNS requested justification for designating as proprietary the discussion of the computer code LS-DYNA in Section 7.5 of the proprietary version of the HI report mentioned above. This request was coordinated with HI. In response, HI concunred with the NRC that this information had previously been made public, and therefore could not be designated as proprietary. HI has revised Section 7.5 of the proprietary and non-proprietary versions of the report. Enclosed is page 7-5 from the non-proprietary version of the report with the revised Section 7.5.
Should you have any questions regarding this matter, please contact me at (402) 825-2904.
Sincerely, David Van Der Kamp Acting Licensing Manager COOPER NUCLEAR STATION00 P.O Box 98 / Brownville, NE 68327-0098 Telephone: (402) 825-3811 / Fax: (402) 825-5211 www.nppd.com 1,
NLS2007056 Page 2 of 2
/IT Enclosure cc: Regional Administrator w/ Enclosure USNRC Region IV Cooper Project Manager w/ Enclosure USNRC - NRR Project Directorate IV-I Senior Resident Inspector w/ Enclosure USNRC - CNS Nebraska Health and Human Service w/ Enclosure Department of Regulation and Licensure NPG Distribution w/o Enclosure CNS Records w/ Enclosure
NLS2007056 Enclosure Page 1 of 2 Enclosure Revised Page 7-5 fiomn Holtec International report HI-2043224 (Non-proprietary)
"Licensing Report on the Wet Fuel Storage Capacity Expansion at Cooper Nuclear Station"
7.5 Mathematical Model In the first step of the solution process, the velocity of the dropped fuel assembly is computed for the condition of underwater free fall in the manner of the formulation presented in the above section. Table 7.5.1 contains the computed velocities for the various drop events. Note that fluid drag was conservatively neglected when calculating the impact velocities used in the finite element model.
In the second step of the solution, an elasto-plastic finite element model for each drop event is prepared with the Holtec QA validated computer code LS-DYNA .. .. ........................
S. .. ... .....
- .... --:7 . ...* ..... -- -- -5..'....... .. ....
To maximize the damage of the rack, the dropped fuel assembly, which includes the additional weight of the handling tool, is assumed to be rigid in all analyses.
. The physical properties of material types undergoing deformation in the postulated impact events are summarized in Table 7.5.2.
Holtec Report HI-2043224 7-5 Project No: 1406 SHADED AREAS DENOTE PROPRIETARY INFORMATION
ATTACHMENT 3 LIST OF REGULATORY COMMITMENTS© 0 ATTACHMENT 3 LIST OF REGULATORY COMMITMENTS',-!
Correspondence Number: NLS2007056 The following table identifies those actions committed to by Nebraska Public Power District (NPPD) in this document. Any other actions discussed in the submittal represent intended or planned actions by NPPD. They are described for information only and are not regulatory commitments. Please notify the Licensing Manager at Cooper Nuclear Station of any questions regarding this document or any associated regulatory commitments.
COMMITMENT COMMITTED DATE COMMITMENT NUMBER OR OUTAGE None i +
i +
I PROCEDURE 0.42 REVISION 21 PAGE 18 OF 25 1