rBook 3 of 18-1 hill
-A 4
'~*~
U Final Status Survey Final Report Phase VI Appendix A2 Survey Unit Release Record 9304-0002, Southwest Protected Area Grounds February 2007
CYAPCO FINAL STATUS SURVEY RELEASE RECORD SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 K-Prepared By:
K-t
'ý'S-e5*
FSS Engineer U
Reviewed By:
A S Engineer Approved By:
A-7 Technical Support Manager Date: /c-/b-C)C Date:
t4~r(
Date:
/
/
Revision 0
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD TABLE OF CONTENTS
- 1.
SURVEY UNIT DESCRIPTION......................................................
3
- 2.
CLASSIFICATION BASIS................................................................
3
- 3.
DATA QUALITY OBJECTIVES (DQO)..........................................
6
- 4.
SU RV EY D ESIGN.............................................................................
9
- 5.
SURVEY IMPLEMENTATION.......................................................
12
- 6.
SU RVEY RESU LTS........................................................................
13
- 7.
QUALITY CONTROL....................................................................
20
- 8.
INVESTIGATIONS AND RESULTS.............................................
20
- 9.
REMEDIATION AND RESULTS..................................................
20
- 10. CHANGES FROM THE FINAL STATUS SURVEY PLAN......
21
- 11. DATA QUALITY ASSESSMENT (DQA)......................................
21
- 12. A N O M A LIE S....................................................................................
22
- 13. CO N CLU SION................................................................................
22
23 14.1 Attachment 1 - Figures (6 pages including cover) 14.2 Attachment 2 - Scan Results (4 pages including cover) 14.3 Attachment 3 - Laboratory Results (84 pages including cover) 14.4 Attachment 4-DQA Results (16 pages including covers)
TOTAL 133 Revision 0
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD SURVEY UNIT DESCRIPTION Survey Unit 9304-0002 (Southwest Protected Area Grounds) is designated as Final Status Survey (FSS) Class 1 and consists of 1,268 m2 (0.313 acres) of uninhabited open land located approximately four hundred twenty (420) feet from the reference coordinate system benchmark used at Haddam Neck Plant (HNP)
(see Attachment 1).
The survey unit is bounded by Survey Unit 9306-0000, a Class 2 survey unit, on the east side and by Survey Unit 9304-0001, a Class 2 survey unit, on the three remaining sides. The survey unit is comprised of predominantly flat disturbed open land that gently slopes from east to west toward the Connecticut River.
The reference coordinates associated with this survey unit are E004 through E006 by S067 through S068. Section 5.4.4 of the License Termination Plan (LTP) identifies the requirement for a reference coordinate system for FSS. The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may not be part of this survey unit. The boundary of the survey unit was defined using a Global Positioning System (GPS) based on the Connecticut State Plane System North American Datum (NAD) 1927.
- 2.
CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10, "Survey Unit Classification." The historical information, scoping analyses and characterization results provided sufficient data to designate Survey Unit 9304-0002 as Class 1 in August 2006.
The "Classification Basis Summary" conducted for Survey Unit 9304-0002 consisted of:
a) A review of the 10CFR50.75 (g) (1) database, b) A review of the "Initial Characterization Report" and the "Historic Site Assessment Supplement,"
c) Historic and current survey records review, d) Visual inspections and a "walkdown."
A review of the 10CFR50.75(g)(1) database report identifies twenty-four (24) documents associated with or relating to this survey area.
Two (2) of the twenty-four (24) documents identified pertain to the current radiological conditions of this survey unit at the time of this report.
a) HP 98-493: Analyses of Samples Taken east of the Intake Screen House-Bus 10 Modification. - Four (4) asphalt and seven (7) soil samples to a depth of two (2) feet were collected due East of the Screen House. The samples were analyzed on-site by gamma spectroscopy.
Revision 0 3
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD The results indicate that no plant derived radionuclides were present at quantities above detection limits.
b) HP 99-111 Analysis of Samples Taken for Proposed Trench from Screen House to Security Building (PAP). - Four (4) asphalt and ten (10) soil samples to a depth of two (2) feet were collected due East of the Screen House.
The samples were analyzed on-site by gamma spectroscopy.
The results indicate that no plant derived radionuclides were present at quantities above detection limits.
In May of 2006, while performing a Radiological Assessment of Survey Area 9304 during removal of Circulating Water piping system, soil was removed from the area and was staged in piles around the west-northwest edge of the excavation. Survey and sampling was being performed on the removed soil at selected, and accessible, locations along the base of the piles.
Survey and sampling was conducted under SSWP 06-03-002. On May 9, 2006 an area of elevated activity was identified on a pile by direct scan measurement using an E-600 with a SPA-3 probe. The maximum response was 168,000 counts per minute (cpm) according to the survey.
The locations were evaluated, and Cs-137 was confirmed to be present.
A sample was collected (9304-0000-037RACR) and analyzed using gamma spectroscopy. The results indicated that the Cs-137 activity present in the sample was 897 pCi/g and the Cobalt-60 (Co-60) activity present in the sample was 9.51 pCi/g. The area of the pile was remediated until no further elevated activity was identified.
Subsequent sampling confirmed the remediation was successful in removing residual activity.
Based on the levels of activity and the fact that a remediation was conducted in the area, Survey Unit 9304-0002, a Class 1 Survey Unit, was established around the area of remediation to ensure that the proper level of FSS surveys and sampling were conducted in accordance with the LTP.
A review of the "Initial and Supplemental Characterization Reports" as well as the previous "Classification Basis Summaries" provided no additional information pertinent to classification.
A characterization survey plan was initiated and executed by Site Closure personnel, in August 2006, to determine existing conditions and obtain radiological data for Final Status Survey (FSS).
Six (6) samples were collected within Survey Unit 9304-0002 and analyzed on-site using gamma spectroscopy.
Five (5) of the six (6) sample results were determined to be less than the established criteria for detection (i.e., a radionuclide is considered to be detected if the result is greater than two standard deviations of uncertainty).
One sample, sample number 9304-02-005, was above the criteria for detection.
The sample concentration was 0.056 pCi/g for Cs-137 and 0.036pCi/g for Co-60 or 2.7% of the Operational Derived Concentration Revision 0 4
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD Guideline Level (DCGL).
The Cs-137 levels were consistent with those concentrations in soil as determined from off-site locations as documented by Health Physics Technical Support Document (TSD)
BCY-HP-0063, "Background Cs-137 Concentration in Soil." Characterization results showed Cs-137 and Co-60 to be the isotopes of concern for FSS planning purposes (refer to Table 1).
Table 1 -
Basic Statistical Quantities for Cesium-137 and Cobalt-60 from the Characterization Survey Parameter Cs-137 (pCi/g)
Co-60 (pCi/g)
Minimum Value:
-1.30E-02
-1. 18E-02 Maximum Value:
5.59E-02 3.56E-02 Mean:
1.31E-02 6.53E-03 Median:
1.1 9E-02 4.42E-03 Standard deviation:
2.60E-02 1.77E-02 Note: The Operational DCGLs are 4.75 pCi/g for Cs-137 and 2.29 pCi/g for Co-60; these are used in conjunction with the unity rule to achieve 15 mrem/yr Total Effective Dose Equivalent (TEDE)
Additionally, sample number 9304-02-003C was analyzed by the off-site laboratory for Hard-To-Detect (HTD) radionuclides.
Material Service Requisition (MSR) number 06-1083 was generated to cover the analysis of the samples at the approved off-site laboratory.
The results of the HTD sample analysis indicated that there were no sample results above the established criteria for detection (i.e., a result greater than two standard deviations of uncertainty).
The FSS Engineer performed a visual inspection and walk-down during August 2006 to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions.
This survey area is affected by both existing and future groundwater (reference CY memo ISC 06-024) which will be a source of dose from residual radioactivity, as discussed in Section 3 under the Data Quality Objectives.
Based upon the historical information and the results of radiological surveys performed during characterization, it was concluded that there was a low probability for residual radioactivity to be present in this survey unit in concentrations greater than the Operational DCGLs, justifying a final survey unit classification of Class 1 (refer to Section 3).
Revision 0 5
Revision 0 5
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD
- 3.
DATA QUALITY OBJECTIVES (DQO)
FSS design and planning used the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5.1-11, "Preparation of Final Status Survey Plan, " and the "Multi-Agency Radiation Survey and Site Investigation Manual" (MARSSIM). A summary of the main features of the DQO process are provided herein.
The DQO process incorporated hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is technically known as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection. In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would indicate that residual activity within the survey unit does not exceed the release criteria.
Probabilistic sampling is a preferred method to select a sample so that each item in the population being studied has a known likelihood of being included in the sample.
The primary objective of the Final Status Survey Plan (FSSP) was to demonstrate that the level of residual radioactivity in Survey Unit 9304-0002 did not exceed the release criteria as specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).
A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity. This is done through the development of Derived Concentration Guideline Levels (DCGLs).
The DCGLs represent average levels of radioactivity above background levels and are presented in terms of surface or mass activity concentrations. Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL), existing groundwater radioactivity and future groundwater radioactivity that will be contributed by building basements and footings.
The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity.
Equation 1 shows the mathematical relationship between the three (3) components and the total dose.
Equation 1 H Total H Soil + HExistingGW + HFutureGW Revision 0 6
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD The total dose under the LTP criteria is twenty-five (25) mrem/yr TEDE from all three components.
The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for CY is nineteen (19) mrem/yr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from soil must be reduced when using the existing and future groundwater dose values discussed above.
This survey area is affected by existing groundwater (reference CY memo ISC 06-024). Therefore, the dose contribution from existing groundwater is two (2) mremlyr TEDE.
This survey unit is considered impacted by future groundwater radioactive contamination, as there are buried concrete foundations or footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024).
The dose contribution from future groundwater, the third dose component is, therefore, two (2) mrem/yr TEDE.
Equation 2 19 mrem/yrrot, = 15 mrem/yrsoil + 2 mrem/yrExisting GW+ 2 mrem/yrFutureGW The allowable dose for soil in this survey unit is fifteen (15) mrem/yr TEDE as shown by Equation 2 above. The concentration of residual radioactivity resulting in fifteen (15) mrem/yr TEDE is designated as the Operational DCGL, and has been established for the radionuclides of concern as provided in Table 2.
Revision 0 7
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD Table 2 - Radionuclide Specific Base Case Soil DCGL, Operational DCGLs and Required Minimum Detectable Concentrations Base Case Soil Operational DCGL Required Radionuclide pig(3 (1)
DCGL (pCi/g) (3)
MDC (pCi/g) (2)
(pCi/g) (4)
H-3 4.12E+02 2.47E+02 1.65E+01 C-14 5.66E+00 3.40E+00 2.26E-01 Mn-54 1.74E+01 1.04E+01 6.96E-01 Fe-55 2.74E+04 1.64E+04
- 1. 1OE+03 Co-60 3.81E+00 2.29E+00 1.52E-01 Ni-63 7.23E+02 4.34E+02 2.89E+01 Sr-90 1.55E+00 9.30E-01 6.20E-02 Nb-94 7.12E+00 4.27E+00 2.85E-01 Tc-99 1.26E+01 7.56E+00 5.04E-01 Ag-108m 7.14E+00 4.28E+00 2.86E-01 Cs-134 4.67E+00 2.80E+00 1.87E-01 Cs-137 7.91E+00 4.75E+00 3.16E-01 Eu-152 1.01E+01 6.06E+00 4.04E-01 Eu-154 9.29E+00 5.57E+00 3.72E-01 Eu-155 3.92E+02 2.35E+02 1.57E+01 Pu-238 2.96E+01 1.78E+01 1.18E+00 Pu-239/240 2.67E+01 1.60E+01 1.07E+00 Pu-241 8.70E+02 5.22E+02 3.48E+01 Am-241 (5) 2.58E+01 1.55E+01 1.03E+00 Cm-243/244 2.90E+0 1 1.74E+01 1.16E+00 (1)
(2)
(3)
(4)
(5)
Bold indicates those radionuclides considered to be hard to detect The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to 25 mrem/yr TEDE.
The Operational DCGL is equivalent to 15 mrem/yr TEDE.
The required MDC is equivalent to 1 mrem/yr TEDE.
Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD). The preferred result is the alpha spectroscopy's when both analyses are performed.
Revision 0 8
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability.
Six (6) samples were collected and analyzed during characterization as discussed in Section 2. The samples were collected through systematic sampling over a simple grid design.
One characterization sample was analyzed for Hard to Detect (HTD) radionuclides.
Cs-137 was found to be the predominate radionuclide of concern.
Co-60 was included in the survey design based on historical information. The mean and variability of Cs-137 and Co-60 in soil in this survey unit was determined during characterization and are provided in Table 1.
Instrument DQOs included a verification of the ability of the survey instrument to detect the radiation(s) of interest relative to the DCGL. Survey instrument response checks were required prior to issue and after the instrument had been used. Control and accountability of survey instruments was required to assure the quality and prevent the loss of data.
As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. Results reported as less than Minimum Detectable Concentration (<MDC) were not accepted for FSS. Sample report summaries included unique sample identification, analytical
- method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.
- 4.
SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in Procedure RPM 5.1-11, "Preparation of Final Status Survey Plans".
The FSSP uses an integrated sample design that combines scanning surveys and sampling which can be either random or biased.
Characterization sampling was used to determine concentration variability. The samples were collected through systematic sampling over a simple grid design.
The DQO process determined that Cs-137 and Co-60 would be the radionuclides of concern in 9304-0002 (refer to Section 3).
The sum of fractions or unity rule was used with the individual Operational DCGLs because multiple radionuclides (Cs-137 and Co-60) are considered in the survey design.
Other radionuclides identified during FSS were evaluated to ensure adequate survey design.
Surrogate DCGLs were not required for this survey unit based on process knowledge from FSS of nearby adjacent areas and via screening under LTP Section 5.4.7.2, "Gross Activity DCGLs".
Radionuclide screening or de-selection is a process where an individual radionuclide or aggregates may be considered insignificant and eliminated from the FSS.
The criteria for de-selection are concentrations less than 5% for individual radionuclides and less than 10% for aggregates.
Revision 0 9
Revision 0 9
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD The Elevated Measurement Comparison (EMC) count rate equivalent was determined to be 3,178 cpm above background, in accordance with Procedure RPM 5.1-11.
The Sign Test was selected as the non-parametric statistical test. The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation.
This approach was conservative since it included background Cs-137 as part of the sample set.
The number of soil samples for FSS was determined in accordance with Procedure RPM 5.1-12, "Determination of the Number of Surface Samples for Final Status Survey." The Lower Bound of the Gray Region (LBGR) was set in accordance with Procedure RPM 5.1-11 to 4.7 to maintain the relative shift (A/5) in the range of 1 and 3.
The resulting Relative Shift was 2.0.
A Prospective Power Curve was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of the MARSSIM in support of the decommissioning license termination rule (10 CFR 20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design.
Survey design specified fifteen (15) surface soil samples for non-parametric statistical testing.
The grid pattern and locations of the soil samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, "Identifying, and Marking Surface Sample Locations for Final Status Survey."
Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A systematic triangular grid pattern with a random starting point was selected for sample design, which is appropriate for a Class 1 area.
Judgmental sampling was included as a feature of this survey design to account for any anomalies potentially identified in the field.
Sample locations were identified using AutoCAD-LT, a commercially available plotting software package with coordinates consistent with the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 3.
Revision 0 10
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD Table 3 -
Sample Measurement Locations with Associated GPS Coordinates Designation Northing Easting 9304-0002-001IF 236374.55 668548.03 9304-0002-00IFS 9304-0002-002F 236374.55 668515.51 9304-0002-003F 236346.39 668499.25 9304-0002-004F 236318.22 668482.98 9304-0002-004FS 9304-0002-005F 236318.22 668515.51 9304-0002-006F 236346.39 668531.77 9304-0002-007F 236346.39 668564.29 9304-0002-008F 236318.22 668548.03 9304-0002-009F 236290.06 668531.77 9304-0002-OIOF 236261.89 668548.03 9304-0002-011F 236290.06 668564.29 9304-0002-012F 236318.22 668580.55 9304-0002-013F 236318.22 668613.07 9304-0002-014F 236290.06 668596.81 9304-0002-015F 236261.89 668580.55 Although Procedure RPM 5.1-11 only specified that 5% of the samples are required to be selected for HTD analysis, two (2) soil samples or 13% of the number of samples that would be used for non-parametric statistical testing were randomly selected for HTD radionuclide analysis using the Microsoft Excel "RANDBETWEEN" function. Each sample was sent off-site for a full suite analysis of the HTD radionuclides specified in the LTP, Table 2-12, "Radionuclides Potentially Present at Haddam Neck Plant" and as provided in Table 2.
The implementation of quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey," included the collection of two (2) soil samples for "split sample" analysis by the off-site laboratory. These locations were selected randomly using the Microsoft Excel "RANDBETWEEN" function.
Two (2) sample locations were identified as requiring split samples to be collected and analyzed.
Revision 0 11 Revision 0 11
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD Based on the LTP requirements for a Class 1 land area, the total surface area to be scanned was 100% of the survey unit. A map of the scan grid is provided in.
For this Class 1 survey unit, the "Investigation Level" for area scanning and soil sample measurement results are those levels specified in LTP, Table 5-8. Table 4 provides a synopsis of the survey design.
Table 4 -
Synopsis of the Survey Design Feature Design Criteria Basis Survey Unit Land Area 1,268 m2 Based on AutoCAD-Lt and Visual Sample Plan calculations Type 1 and Type 2 errors were 0.05, sigma was 0.045 pCi/g, Number of Measurements 15 the LBGR was adjusted to 4.66 to maintain Relative Shift in the range of 1 and 3 Grid Spacing 9.88 m Based on triangular grid 4.75 pCi/g Cs-137 Administratively set to achieve Operational DCGL 2.29 pCi/g Co-60 15 mrem/yr TEDE (1)
Slv 4.75 pCi/g Cs-137 The Operational DCGL meets Soil Investigation Level pCi/g Co-60 the LTP criteria for a Class 1 survey unit The LTP requires 100% area Scan Survey Area 100% of the area coverage for Class 1 Survey Coverage Units.
>DCGLEMC Administratively set to achieve Scan Investigation Level (or 3,178 cpm 15 mremlyr TEDE above background)
(1) The allowable dose for soil in this survey unit is 15 mrem/yr TEDE as the bounding dose from existing and future groundwater has been established based on field data (reference CY memo ISC 06-024.)
- 5.
SURVEY IMPLEMENTATION Final status survey field activities were conducted under Work Plan and Inspection Record (WP&IR) 2006-0038.
The WP&IR package included a detailed FSSP, job safety analysis, job planning checklist and related procedures for reference. Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey.
The "Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.
Revision 0 12
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD Scan surveys were performed on 100% of the surface area of Survey Unit 9304-0002.
Grid lines, one meter wide, were painted on the ground of the entire survey unit. A background survey was performed around the survey unit and it was determined that the range of background measurements, using an Eberline E-600 with a SPA-3 sodium iodide detector.
The entire survey unit was scanned for elevated readings (see Attachment 2 for all scan results).
Scanning was performed with an Eberline E-600 using a SPA-3 sodium iodide detector. The E-600 was operated in the rate-meter mode and used with audio response. The probe was positioned as close to the ground as possible and was moved at a scan speed of about 0.5 meters per second.
Measurement locations were identified in North American Datum (NAD) 1927 coordinates using GPS; fixed sample measurement locations were identified and marked with a surveyor's flag or paint for identification. At each fixed sample measurement location, a one (1) meter radius around the sample flag or paint mark was scanned for elevated radiation levels.
Fifteen (15) surface soil samples were collected and packaged in accordance with Haddam Neck Plant (HNP) Procedure RPM 5.1-3, "Collection of Sample Media for Final Status Survey" and FSS design.
Samples were controlled, transported, stored, and transferred to the off-site laboratory using Chain-of-Custody (COC) protocol in accordance with Procedure RPM 5.1-5, "Chain of Custody for Final Status Survey Samples."
Two (2) samples (9304-0002-005F and 9304-0002-008F) were randomly selected for HTD radionuclide analysis by the off-site laboratory.
The implementation of quality control measures included the collection of two (2) samples (9304-0002-00IF and 9304-0002-004F) for "split sample" analysis.
- 6.
SURVEY RESULTS All field survey activities were conducted between August 18 and August 22, 2006.
On August 18, 2006, the area was scanned in accordance with the Final Status Survey Plan (FSSP). Two (2) elevated measurement locations were identified during scanning. Two (2) judgmental or biased samples were collected at the elevated measurement locations.
The samples collected at elevated measurement locations were 9304-0002-016F and 9304-0002-017F.
A map identifying all of the sample locations is provided in Attachment 1.
The seventeen (17) fixed sample measurement locations identified in the FSS plan were scanned over approximately a one (1) meter radius for elevated radiation levels. Table 5 provides an overview of the scan results for fixed sample measurement locations. All scan results are provided in Attachment 2.
Revision 0 13
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD Table 5 -
Scan Results for Sample Measurement Locations Sample Highest Logged Action Level (1)
Measurement Reading (kcpm)
> Action Level (2)
Location (kcpm) 1 10.0 10.8 NO 2
10.2 11.5 NO 3
9.1 10.6 NO 4
8.9 10.7 NO 5
11.1 12.2 NO 6
8.4 10.6 NO 7
8.9 10.9 NO 8
10.7 11.0 NO 9
10.7 11.4 NO 10 10.1 12.2 NO 11 10.9 12.2 NO 12 11.8 12.2 NO 13 10.2 11.9 NO 14 10.6 13.2 NO 15 9.6 11.7 NO 16 62.9 17.7 YES(3) 17 150 14.1 YES(3)
(1) The action level is based on a measurement above ambient background in accordance with the FSSP.
(2) FSS sample plans require movement of the sample measurement location to the area within the 1 meter radius yielding the response above the action level.
(3) Judgmental sample location identified during scanning as an elevated measurement location.
Table 6 provides an overview of the scan area survey. All scan results are provided in Attachment 2.
Revision 0 14 Revision 0 14
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD Table 6 - Scan Area Results Highest Elevated Row Logged Action Level
>Action Reading Investigation Number Reading (kcpm) ()
Level (2)
Identification Sample (kcpm)
(3) 1 10.1 10.9 NO NA NA 2
9.4 10.0 NO NA NA 3
8.5 9.7 NO NA NA 4
8.5 10.9 NO NA NA 5
8.8 10.7 NO NA NA 6
8.3 10.8 NO NA NA 7
10.1 11.6 NO NA NA 8
9.9 11.3 NO NA NA 9
9.0 12.6 NO NA NA 10 8.4 10.8 NO NA NA 11 9.2 12.1 NO NA NA 12 9.7 12.3 NO NA NA 13 10.0 12.6 NO NA NA 14 10.0 13.4 NO NA NA 15 10.4 12.3 NO NA NA 16 9.1 12.2 NO NA NA 17 10.2 12.0 NO NA NA 18 10.6 11.6 NO NA NA 19 10.1 13.0 NO NA NA 20 10.7 12.8 NO NA NA 21 9.8 12.6 NO NA NA 22 9.5 12.0 NO NA NA 23 9.4 11.7 NO NA NA 24 10.8 11.7 NO NA NA 25 11.0 13.2 NO NA NA 26 11.2 12.7 NO NA NA 27 10.8 12.5 NO NA NA Revision 0 15 Revision 0 15
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD Table 6 -
(continued)
Highest Elevated Row Logged Action Level
>Action Reading Investigation Number Reading (kcpm) ()
Level (2)
Identification Sample (kcpm)
(3) 28 11.6 12.8 NO NA NA 29 11.7 12.7 NO NA NA 29 58.9 12.7 YES 9304-02-ER-01-29-1 9304-0002-016F 30 10.7 12.6 NO NA NA 31 12.4 13.5 NO NA NA 32 11.3 12.8 NO NA NA 33 11.5 13.9 NO NA NA 33 17.3 13.9 YES 9304-02-ER-01-33-1 9304-0002-017F 34 10.2 12.9 NO NA NA 35 11.1 12.1 NO NA NA 36 11.2 13.0 NO NA NA 37 13.2 14.2 NO NA NA 38 11.1 12.1 NO NA NA 39 11.1 13.8 NO NA NA 40 10.8 12.0 NO NA NA 41 11.6 12.2 NO NA NA 42 11.5 13.1 NO NA NA 43 11.5 14.5 NO NA NA 44 10.9 12.9 NO NA NA 45 10.3 13.5 NO NA NA 46 10.8 11.7 NO NA NA 47 10.4 11.6 NO NA NA (1)
(2)
The action level is based on a measurement above ambient background.
Elevated areas were determined to be NORM, refer to Section 8.
Two (2) judgmental or biased samples were collected at elevated measurement locations identified above.
The samples collected at elevated locations were 9304-0002-016F and 9304-0002-017F.
The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories (GEL), LLC, Charleston, South Carolina.
The laboratory analyzed the fifteen (15) samples collected for non-parametric Revision 0 16
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD statistical testing, the associated duplicates, and the two (2) biased samples using gamma spectroscopy. Gamma spectroscopy analysis was performed to the required MDCs. Gamma spectroscopy results identified some radionuclides meeting the established criteria for detection (i.e., a result greater than two standard deviations uncertainty).
Cs-137 was identified in two (2) of the fifteen (15) samples collected for non-parametric statistical testing. Co-60 was also identified in two (2) of the fifteen (15) samples collected for non-parametric statistical testing.
The mean of the gamma spectroscopic analysis results for the samples indicated that Cs-137 was present at levels that are similar to the concentrations of Cs-137 found in soil at off-site locations within the vicinity of the HNP as presented in the Health Physics TSD BCY-HP-0063. The mean of the gamma spectroscopic analysis results for the samples indicated that Co-60 was present at very low levels in two (2) samples and at levels below the established detection limit, of 2G, in the remaining thirteen (13) samples collected and analyzed for non-parametric testing.
A summary of the results of the fifteen (15) samples collected for non-parametric statistical testing is provided in Table 7.
Table 7 - Summary of Soil Sample Results Cs-137 Co-60 Sample Number pCi/g pCi/g 9304-0002-001F 1.59E-02 8.81E-03 9304-0002-002F
-8.36E-03 1.30E-02 9304-0002-003F
-3.16E-03
-7.74E-05 9304-0002-004F 8.31E-03 2.53E-02 9304-0002-005F 7.01E-03 1.23E-03 9304-0002-006F 9.55E-03 5.27E-03 9304-0002-007F 1.68E-02
-6.86E-03 9304-0002-008F 1.27E-03
-1.06E-03 9304-0002-009F
-8.14E-03
-2.82E-03 9304-0002-01 OF
-2.18E-03
-2.71 E-03 9304-0002-011F 2.79E-03
-2.76E-03 9304-0002-012F 1.07E-02 2.42E-02 9304-0002-013F 4.38E-02 2.22E-02 9304-0002-014F 2.40E-02 1.20E-02 9304-0002-015F 3.11E-02 1.57E-02 Revision 0 17
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD The "sum-of-fractions" or "unity rule" is the mathematical test used to evaluate compliance with radiological criteria for license termination when more than one radionuclide has been determined to be potentially present. The unity rule is:
Equation 3 Cl
+
C 2 C__
DCGLI DCGL2
- DCGL, Where:
Cn = concentration of radionuclide n and DCGLn = DCGL of radionuclide n.
The results of the unity rule calculation for the radionuclides of concern in the statistical sample population for Survey Unit 9304-0001 are provided in Table 8 below.
Table 8-Results of Unity Calculation for Surface Soil Samples Comprising the Statistical Sample Population Fraction of the Operational Sample Number DCGL(1) (2)
Unity Cs-137 Co-60 9304-0002-001F 9304-0002-002F 9304-0002-003F 9304-0002-004F 0.011 0.011 9304-0002-005F 9304-0002-006F 9304-0002-007F 9304-0002-008F 9304-0002-009F 9304-0002-OIOF 9304-0002-01 IF 9304-0002-012F 0.011 0.011 9304-0002-013F 0.009 0.009 Revision 0 18
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD Table 8 -
Results of Unity Calculation for Surface Soil Samples Comprising the Statistical Sample Population Fraction of the Operational Sample Number DCGL(') (2)
Unity Cs-137 Co-60 9304-0002-014F 9304-0002-015F 0.007 0.007 (1)
The Operational DCGL from Table 2 is 4.75 pCi/g for Cs-137 and 2.29 pCi/g for Co-60 to achieve fifteen (15) mrem/yr TEDE respectively.
(2)
- indicates that the radionuclide was not positively detected in the sample The off-site laboratory also processed two (2) samples for HTD analysis as required by the sample plan.
The requested analyses included alpha spectroscopy, gas proportional counting, and liquid scintillation depending on the radionuclide and the measurement method. All analyses met the required MDC.
Table 8 lists the results for those HTD radionuclides meeting the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty) in one sample.
As previously stated in Section 4 of this report, the criteria for de-selection of a radionuclide is a concentration that is less than 5% of the Operational DCGL for individual radionuclides and less than 10% of the Operational DCGLs for aggregates. The HTD radionuclides identified in Table 8 meet the criteria for de-selection since their ratios are 2.2% for Cm-243/244, 2.1% for Pu-241, and 1.3% for Ni-63 with an aggregate total of 5.8%.
Therefore, Cm-243/244, Pu-241, and Ni-63 will not be considered in the final dose determination for this survey unit Table 9 - Hard-to-Detect Sample Results Cm-243/244 Pu-241 Ni-63 Fraction Fraction Fraction Sample Activity of Activity of Activity of (pCi/g)
DCGLop (pCi/g)
DCGLop (pCi/g)
DCGLop (1)
(1)
(1) 9304-0002-005F 3.75E-01 2.20E-02 1.1OE+O1 2.1OE-02 9304-0002-008F 9.11 E+00 1.30E-02 (1)
The Operational DCGL from Table 2 is 17.4 pCi/g for Cm-243/244, 522 pCi/g for Pu-241, and 723 pCi/g for Ni-63.
(2)
- indicates that the radionuclide was not positively detected in the sample Revision 0 19 Revision 0 19
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD Two (2) judgmental samples were collected at locations selected by FSS Supervision based on professional judgment and observation.
Gamma spectroscopy analysis was performed by the off-site laboratory to the required MDC. None of the samples exceeded 3% of the Operational DCGL. No further action or investigations were required (see Table 9).
Table 10 -
Judgmental or Biased Sample Results Fraction of the Sample Number (pCi/g)
(pCi/g)
Operational 9304-0002-016F 6.31E-02 1.77E-02 0.021 9304-0002-017F 2.92E-02
-1.01E-02 0.006 (1) The Operational DCGLs from Table 2 are 4.75 pCi/g for Cs-137 and 2.29 pCi/g for Co-60 and are used in conjunction with the unity rule
- 7.
QUALITY CONTROL The off-site laboratory processed the split samples and performed gamma spectroscopy analysis. Two (2) samples, or 13% of the total number of samples selected for Non-Parametric analysis, were split and analyzed by an off-site laboratory. The data were evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 as detailed in HNP Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey." There was unacceptable agreement between field split results for Cs-137 and Co-60 which was due to very low levels of activity reported that were generally approaching or below instrumentation detection limits. Assessment of the QC Split Samples was performed by using the reported results for NORM which resulted in acceptable agreement.
The sample analysis vendor, GEL maintains quality control and quality assurance plans as part of normal operations.
Refer to Attachment 3 and for data and data quality analysis results.
- 8.
INVESTIGATIONS AND RESULTS No investigations were conducted.
- 9.
REMEDIATION AND RESULTS Historically, no radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit as a result of the FSS. Health Physics TSD BCY-HP-0078, "ALARA Evaluation of Soil Remediation in Support of Final Status Survey, " determined that remediation beyond that required to meet the release criteria to be unnecessary and that the remaining residual radioactivity in soil was ALARA.
Revision 0 20
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD
- 10.
CHANGES FROM THE FINAL STATUS SURVEY PLAN No changes were made to the FSS plan.
- 11.
DATA QUALITY ASSESSMENT (DQA)
The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "Data Quality Assessment, " for completeness and consistency.
The sampling design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs. The evaluation of the Sign Test results demonstrates that the survey unit passes the unrestricted release criteria, thus, the null hypothesis is rejected.
Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 1.
The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation). The standard deviation was slightly less than the value used for the survey design. This would indicate that the number of samples collected was sufficient to meet the Operational DCGL. The mean and median values are well below the Operational DCGL as applied through the use of the unity rule. Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power.
Therefore, the survey unit meets the unrestricted release criteria with adequate power as required by the DQOs.
For Cs-137, the range of the data, about three (3) standard deviations, was not a particularly large variation considering that the levels were essentially at existing environmental levels where such variation is to be expected.
The difference between the mean and median was 17% of the standard deviation which indicates some skewness in the data.
The data was represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot indicates a positive skewness as confirmed by the calculated skew of 0.91.
For Co-60, the range of the data, about three (3) standard deviations, was not a particularly large variation considering that the levels were at extremely low levels where such variation is to be expected. The difference between the mean and median was 29% of the standard deviation which indicates a small skewness in the data. The data was represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot shows a positive skewness as confirmed by the calculated skew of 0.47.
All data, assessments, and graphical representations are provided in Attachment 4.
Revision 0 21
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD
- 12.
ANOMALIES The anomalies associated with the poor agreement range between the field splits were presented in Section 7. The source of the disagreement for Cs-137 and Co-60 is likely due to the extremely low levels of activity being reported and the statistical uncertainties associated with the comparison of very small numbers.
GEL, the off-site laboratory reported one (1) Nonconformance Report (NCR) relating to the sample analysis for this survey unit. The analyst did not scan the samples into the batch prior to analysis. However, the samples did remain in their custody at all times. The error has been corrected and the analyst has been instructed on the proper procedures. This NCR did not affect the sample results for this survey unit.
No other anomalies were noted.
- 13.
CONCLUSION Survey Unit 9304-0002 has met the final DQOs of the FSS plan. The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved. Elevated Measurement Comparison and remediation were not required.
The sample data passed the Sign Test. The null hypothesis was rejected. The Retrospective Power Curve generated using COMPASS shows adequate power was achieved. The survey unit was properly designated as Class 1.
The dose contribution from soil is 0.08 mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.
This survey area is affected by existing groundwater (reference CY memo ISC 06-024); therefore, the dose contribution from existing groundwater is two (2) mrem/yr TEDE.
This survey unit is also considered impacted by future groundwater radioactive contamination, as there are underground foundations and footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024); therefore, the dose contribution from future groundwater is two (2) mremlyr TEDE.
The average total dose from residual radioactivity in this survey unit, including exposures from the three (3) components as described in Section 3, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity, will not exceed 4.08 mrem/yr TEDE.
Therefore, Survey Unit 9304-0002 is acceptable for unrestricted release.
Revision 0 22
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD
- 14.
ATTACHMENTS 14.1 Attachment 1 - Survey Unit Location Map 14.2 Attachment 2 - Scan Results 14.3 Attachment 3 - Laboratory Results 14.4 Attachment 4 - DQA Results Revision 0 23 Revision 0 23
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD ATTACHMENT 1 (FIGURES)
Revision 0
-S
- )
K' f
W-UE1J&14 im Am-IConnecticut Yankee Atomic Power Company Site Map With Reference To Survey Unit 9304-0002
9304-0002
= Sampleat Elevated Scan Location 5
11 00 400 009 10 05 15 9304-0001 Connecticut Yankee Atomic Power Company 9304-0002 FINAL STA TUS SUR VEY SAMPLE LOCATIONS
9304-0002 Alk A 0.016
-0.008 U.Ul'/
04 0.063 04 0.0 z 0.010 0.01114 &0.029 Mr:;&
I
-0.003 00 0.008
=&amleat Elevated Scan Location Note:
Cesium-137 residts aV given in p Ci/g 0.007 0.001
-0.008 0.003 00
-0.002 0.024 0
0.031 9304-0001 Connecticut Yankee Atomic Power Company Date By FIGURE 3 9304-0002 Final Status Survey Design October R.Massengill Cesium-137Posting Plot I
2006IR.Massel
9304-0002 AO a
0.009 0.013fo
-U.UU07
&30.022 04 0.018 0.024 0 &-0.010 0.005 A"
I
-0.001 0
0.025 6
0.001 -0.001 00
-0.003
-0.003 00
-0.003 001 0.012 0.016
= Smplat Locaton Not:
Cobalt-60 resudts am giv in p Mig
-I-l 9304-0001 I
Connecticut Yankee Atomic Power CompanyDaeB FIGURE 4 9304-0002 Final Status Survey Design Cobalt-60 Posting Plot October2006 R.Massengill
9304-0002 Le~gend
= SCAN AREA 9304-0001 eY Connecticut Yankee Atomic Power Company 9304-0002 Final Status Survey Scan Area
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD ATTACHMENT 2 (SCAN RESULTS)
FSS SURVEY UNIT 9304-0002 (CLASS 1 AREA)
SURVEY AREA SCAN DATA Survey Location Log Date Log Time Reading AL
>AL E-600 SIN Probe SIN 9304-02-BC-01-01-0 8/18/2006 10:44:00 9.49E+03 1105 1012 9304-02-SC-01-01-0 8/18/2006 10:47:00 1.01 E+04 1.09E+04 1105 1012 9304-02-BC-01-02-0 8/18/2006 10:35:00 8.69E+03 1105 1012 9304-02-SC-01-02-0 8/18/2006 10:44:00 9.44E+03 1.OOE+04 1105 1012 9304-02-BC-01-03-0 8/18/2006 10:30:00 8.38E+03 1105 1012 9304-02-SC-01-03-0 8/18/2006 10:34:00 8.51E+03 9.69E+03 1105 1012 9304-02-BC-01-04-0 8/18/2006 10:25:00 9.53E+03 1105 1012 9304-02-SC-01-04-0 8/18/2006 10:28:00 8.53E+03 1.09E+04 1105 1012 9304-02-BC-01-05-0 8/18/2006 10:21:00 9.31EE+03 1105 1012 9304-02-SC-01-05-0 8/18/2006 10:24:00 8.77E+03 1.07E+04 1105 1012 9304-02-BC-01-06-0 8/18/2006 10:16:00 9.43E+03 1105 1012 9304-02-SC-01-06-0 8/18/2006 10:20:00 8.32E+03 1.08E+04 1105 1012 9304-02-BC-01-07-0 8/18/2006 10:12:00 1.02E+04 1105 1012 9304-02-SC-01-07-0 8/18/2006 10:15:00 1.01E+04 1.16E+04 1105 1012 9304-02-BC-01-08-0 8/18/2006 10:07:00 9.85E+03 1105 1012 9304-02-SC-01-08-0 8/18/2006 10:11:00 9.94E+03 1.13E+04 1105 1012 9304-02-BC-01-09-0 8/18/2006 10:03:00 1.11EE+04 1105 1012 9304-02-SC-01-09-0 8/18/2006 10:06:00 9.02E+03 1.26E+04 1105 1012 9304-02-BC-01-10-0 8/18/2006 9:58:00 9.45E+03 1105 1012 9304-02-SC-01-10-0 8/18/2006 10:02:00 8.42E+03 1.08E+04 1105 1012 9304-02-BC-01-11-0 8/18/2006 9:51:00 1.06E+04 1105 1012 9304-02-SC-01-11-0 8/18/2006 9:55:00 9.24E+03 1.21E+04 1105 1012 9304-02-BC-01-12-0 8/18/2006 9:45:00 1.08E+04 1105 1012 9304-02-SC-01-12-0 8/18/2006 9:50:00 9.65E+03 1.23E+04 1105 1012 9304-02-BC-01-13-0 8/18/2006 10:24:00 1.11E+04 1117 1001 9304-02-SC-01-13-0 8/18/2006 10:27:00 1.OOE+04 1.26E+04 1117 1001 9304-02-BC-01-14-0 8/18/2006 10:28:00 1.18E+04 1117 1001 9304-02-SC-01-14-0 8/18/2006 10:31:00 1.OOE+04 1.34E+04 1117 1001 9304-02-BC-01-15-0 8/18/2006 10:34:00 1.08E+04 1117 1001 9304-02-SC-01-15-0 8/18/2006 10:36:00 1.04E+04 1.23E+04 1117 1001 9304-02-BC-01-16-0 8/18/2006 10:38:00 1.07E+04 1117 1001 9304-02-SC-01-16-0 8/18/2006 10:40:00 9.12E+03 1.22E+04 1117 1001 9304-02-BC-01-17-0 8/18/2006 10:41:00 1.05E+04 1117 1001 9304-02-SC-01-17-0 8/18/2006 10:44:00 1.02E+04 1.20E+04 1117 1001 9304-02-BC-01-18-0 8/18/2006 10:45:00 1.02E+04 1117 1001 9304-02-SC-01-18-0 8/18/2006 10:48:00 1.06E+04 1.16E+04 1117 1001 9304-02-BC-01-19-0 8/18/2006 10:49:00 1.15E+04 1117 1001 9304-02-SC-01-19-0 8/18/2006 10:52:00 1.01 E+04 1.30E+04 1117 1001 9304-02-BC-01-20-0 8/18/2006 10:53:00 1.13E+04 1117 1001 9304-02-SC-01-20-0 8/18/2006 10:56:00 1.07E+04 1.28E+04 1117 1001 9304-02-BC-01-21-0 8/18/2006 10:58:00 1.11 E+04 1117 1001 9304-02-SC-01-21-0 8/18/2006 11:01:00 9.79E+03 1.26E+04 1117 1001 9304-02-BC-01-22-0 8/18/2006 11:02:00 1.05E+04 1117 1001 9304-02-SC-01-22-0 8/18/2006 11:04:00 9.54E+03 1.20E+04 1117 1001 9304-02-BC-01-23-0 8/18/2006 11:06:00 1.03E+04 1117 1001 9304-02-SC-01-23-0 8/18/2006 11:08:00 9.41E+03 1.17E+04 1117 1001 9304-02-BC-01-24-0 8/18/2006 11:09:00 1.03E+04 1117 1001 9304-02-SC-01-24-0 8/18/2006 11:12:00 1.08E+04 1.17E+04 1117 1001 9304-02-BC-01-25-0 8/18/2006 11:19:00 1.17E+04 1117 1001 9304-02-SC-01-25-0 8/18/2006 11:21:00 1.1OE+04 1.32E+04 1117 1001 1/31/2007 K:\\Survey Alea Records\\9304\\FSSP\\SAMPLE RESULTS\\AREA AND FIXED LOCATION SCAN TABLES.xIs
FSS SURVEY UNIT 9304-0002 (CLASS 1 AREA)
SURVEY AREA SCAN DATA Survey Location Log Date Log Time Reading AL
>AL E-600 SIN Probe SIN 9304-02-BC-01-26-0 8/18/2006 11:23:00 1.1 2E+04 1117 1001 9304-02-SC-01-26-0 8/18/2006 11:26:00 1.12E+04 1.27E+04 1117 1001 9304-02-BC-01-27-0 8/18/2006 11:27:00 1.10E+04 1117 1001 9304-02-SC-01-27-0 8/18/2006 11:30:00 1.08E+04 1.25E+04 1117 1001 9304-02-BC-01-28-0 8/21/2006 9:53:00 1.13E+04 1105 1012 9304-02-SC-01-28-0 8/21/2006 9:57:00 1.16E+04 1.28E+04 1105 1012 9304-02-BC-01-29-0 8/18/2006 9:22:00 1.12E+04 1117 1001 9304-02-SC-01-29-0 8/18/2006 9:33:00 1.17E+04 1.27E+04 1117 1001 9304-02-ER-01-29-1 8/18/2006 9:47:00 5.89E+04 1.27E+04
+
1117 1001 9304-02-BC-01-30-0 8/18/2006 9:34:00 1.11E+04 1117 1001 9304-02-SC-01-30-0 8/18/2006 9:40:00 1.07E+04 1.26E+04 1117 1001 9304-02-BC-01-31-0 8/18/2006 9:41:00 1.19E+04 1117 1001 9304-02-SC-01-31-0 8/18/2006 9:45:00 1.24E+04 1.35E+04 1117 1001 9304-02-BC-01-32-0 8/18/2006 9:48:00 1.13E+04 1117 1001 9304-02-SC-01-32-0 8/18/2006 9:53:00 1.13E+04 1.28E+04 1117 1001 9304-02-BC-01-33-0 8/18/2006 9:57:00 1.23E+04 1117 1001 9304-02-SC-01-33-0 8/18/2006 10:07:00 1.15E+04 1.39E+04 1117 1001 9304-02-ER-01-33-1 8/18/2006 10:32:00 1.73E+05 1.39E+04
+
1117 1001 9304-02-BC-01-34-0 8/18/2006 10:08:00 1.14E+04 1117 1001 9304-02-SC-01-34-0 8/18/2006 10:12:00 1.02E+04 1.29E+04 1117 1001 9304-02-BC-01-35-0 8/18/2006 10:13:00 1.06E+04 1117 1001 9304-02-SC-01-35-0 8/18/2006 10:16:00 1.11E+04 1.21E+04 1117 1001 9304-02-BC-01-36-0 8/18/2006 10:19:00 1.15E+04 1117 1001 9304-02-SC-01-36-0 8/18/2006 10:22:00 1.12E+04 1.30E+04 1117 1001 9304-02-BC-01-37-0 8/18/2006 8:44:00 1.26E+04 1105 1012 9304-02-SC-01-37-0 8/18/2006 8:48:00 1.32E+04 1.42E+04 1105 1012 9304-02-BC-01-38-0 8/18/2006 8:49:00 1.06E+04 1105 1012 9304-02-SC-01-38-0 8/18/2006 8:53:00 1.11E+04 1.21 E+04 1105 1012 9304-02-BC-01-39-0 8/18/2006 8:54:00 1.22E+04 1105 1012 9304-02-SC-01-39-0 8/18/2006 8:59:00 1.11E+04 1.38E+04 1105 1012 9304-02-BC-01-40-0 8/18/2006 9:00:00 1.05E+04 1105 1012 9304-02-SC-01-40-0 8/18/2006 9:09:00 1.08E+04 1.20E+04 1105 1012 9304-02-BC-01-41-0 8/18/2006 9:10:00 1.07E+04 1105 1012 9304-02-SC-01-41-0 8/18/2006 9:14:00 1.16E+04 1.22E+04 1105 1012 9304-02-BC-01-42-0 8/18/2006 9:16:00 1.16E+04 1105 1012 9304-02-SC-01-42-0 8/18/2006 9:20:00 1.15E+04 1.31E+04 1105 1012 9304-02-BC-01-43-0 8/18/2006 9:21:00 1.29E+04 1105 1012 9304-02-SC-01-43-0 8/18/2006 9:25:00 1.15E+04 1.45E+04 1105 1012 9304-02-BC-01-44-0 8/18/2006 9:26:00 1.14E+04 1105 1012 9304-02-SC-01-44-0 8/18/2006 9:30:00 1.09E+04 1.29E+04 1105 1012 9304-02-BC-01-45-0 8/18/2006 9:31:00 1.199E+04 1105 1012 9304-02-SC-01-45-0 8/18/2006 9:36:00 1.03E+04 1.35E+04 1105 1012 9304-02-BC-01-46-0 8/18/2006 10:54:00 1.04E+04 1105 1012 9304-02-SC-01-46-0 8/18/2006 10:57:00 9.75E+03 1.19E+04 1105 1012 9304-02-BC-01-47-0 8/18/2006 10:59:00 1.02E+04 1105 1012 9304-02-SC-01-47-0 8/18/2006 11:02:00 1.01 E+04 1.1 6E+04 1105 1012 1/31/2007 K:\\Survey 2
a Records\\9304\\FSSP\\SAMPLE RESULTS\\AREA AND FIXED LOCATION SCAN TABLES.xIS
FSS SURVEY UNIT 9304-0002 (CLASS 1 AREA)
FIXED SAMPLE LOCATION SCANS Survey Location Log Date Log Time Reading AL
>AL E-600 S/N Probe SIN 9304-02-BL-00-01-0 8/21/2006 10:04:00 9.41 E+03 1105 1012 9304-02-SL-00-01-0 8/21/2006 10:06:00 1.OOE+04 1.08E+04 1105 1012 9304-02-BL-00-02-0 8/21/2006 10:16:00 1.01E+04 1105 1012 9304-02-SL-00-02-0 8/21/2006 10:20:00 1.02E+04 1.15E+04 1105 1012 9304-02-BL-00-03-0 8/21/2006 10:28:00 9.21E+03 1105 1012 9304-02-SL-00-03-0 8/21/2006 10:30:00 9.09E+03 1.06E+04 1105 1012 9304-02-BL-00-04-0 8/21/2006 10:38:00 9.36E+03 1105 1012 9304-02-SL-00-04-0 8/21/2006 10:40:00 8.90E+03 1.07E+04 1105 1012 9304-02-BL-00-05-0 8/21/2006 10:51:00 1.07E+04 1105 1012 9304-02-SL-00-05-0 8/21/2006 10:54:00 1.11 E+04 1.22E+04 1105 1012 9304-02-BL-00-06-0 8/21/2006 11:03:00 9.19E+03 1105 1012 9304-02-SL-00-06-0 8/21/2006 11:05:00 8.44E+03 1.06E+04 1105 1012 9304-02-BL-00-07-0 8/21/2006 11:13:00 9.50E+03 1105 1012 9304-02-SL-00-07-0 8/21/2006 11:16:00 8.94E+03 1.09E+04 1105 1012 9304-02-BL-00-08-0 8/21/2006 11:20:00 9.62E+03 1105 1012 9304-02-SL-00-08-0 8/21/2006 11:23:00 1.07E+04 1.10E+04 1105 1012 9304-02-BL-00-09-0 8/21/2006 13:15:00 9.94E+03 1105 1012 9304-02-SL-00-09-0 8/21/2006 13:17:00 1.07E+04 1.14E+04 1105 1012 9304-02-BL-00-10-0 8/21/2006 13:26:00 1.07E+04 1105 1012 9304-02-SL-00-10-0 8/21/2006 13:29:00 1.01E+04 1.22E+04 1105 1012 9304-02-BL-00-11-0 8/21/2006 13:37:00 1.07E+04 1105 1012 9304-02-SL-00-11-0 8/21/2006 13:39:00 1.09E+04 1.22E+04 1105 1012 9304-02-BL-00-12-0 8/21/2006 13:45:00 1.07E+04 1105 1012 9304-02-SL-00-12-0 8/21/2006 13:48:00 1.18E+04 1.22E+04 1105 1012 9304-02-BL-00-13-0 8/21/2006 13:51:00 1.04E+04 1105 1012 9304-02-SL-00-13-0 8/21/2006 13:53:00 1.02E+04 1.19E+04 1105 1012 9304-02-BL-00-14-0 8/21/2006 13:58:00 1.17E+04 1105 1012 9304-02-SL-00-14-0 8/21/2006 14:00:00 1.06E+04 1.32E+04 1105 1012 9304-02-BL-00-15-0 8/21/2006 14:05:00 1.03E+04 1105 1012 9304-02-SL-00-15-0 8/21/2006 14:07:00 9.56E+03 1.17E+04 1105 1012 9304-02-BL-00-16-0 8/21/2006 14:14:00 1.59E+04 1105 1012 9304-02-SL-00-16-0 8/21/2006 14:15:00 6.29E+04 1.77E+04
+
1105 1012 9304-02-BL-00-17-0 8/21/2006 14:26:00 1.25E+04 1105 1012 9304-02-SL-00-17-0 8/21/2006 14:27:00 1.50E+05 1.41E+04
+
1105 1012 1/31/2007 K\\,urvey Area Reoords\\9304\\FSSP\\SAMPLE RESULTS\\AREA AND FIXED LOCATION SCAN TABLES.xls
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD ATTACHMENT 3 (LABORATORY DATA)
General Narrative 1
CASE NARRATIVE For CONNECTICUT YANKEE RE: Soil PO# 002332 Work Order: 170544 SDG: MSR#06-1174 September 6, 2006 Laboratory Identification:
General Engineering Laboratories, LLC Mailing Address:
P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address:
2040 Savage Road Charleston, South Carolina 29407 Telephone Number:
(843) 556-8171 Summary:
Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL) in Charleston, South Carolina on August 30, 2006. All sample containers arrived without any visible signs of tampering or breakage. The chain of custody contained the proper documentation and signatures.
The laboratory received the following sample(s):
Sample ID Client Sample ID 170544001 9304-0002-OOIF 170544002 9304-0002-00IFS 170544003 9304-0002-002F 170544004 9304-0002-003F 170544005 9304-0002-004F 170544006 9304-0002-004FS 170544007 9304-0002-006F 170544008 9304-0002-007F 170544009 9304-0002-009F GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP INC.
P.O. Box 30712 - Charleston, SC 29417 ° 2040 Savage Road (29407)
Phone (843) 556-8171 ° Fax (843) 766-1178 ° www.gel.com 2
170544010 170544011 170544012 170544013 170544014 170544015 170544016 170544017 170544018 170544019 9304-0002-01OF 9304-0002-01 IF 9304-0002-012F 9304-0002-013F 9304-0002-014F 9304-0002-015F 9304-0002-016F 9304-0002-017F 9304-0002-005F 9304-0002-008F Items of Note:
There are no items of note.
Case Narrative:
Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are listed below by analytical parameter.
Analytical Request:
Seventeen soil samples were analyzed for FSSGAM.
Two soil samples were analyzed for FSSALL.
Internal Chain of Custody:
Custody was maintained for the sample(s).
Data Package:
The enclosed data package contains the following sections: Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.
I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.
Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.
RO. Box 30712 - Charleston, SC 29417
- 2040 Savage Road (29407)
Phone (843) 556-8171
- Fax (843) 766-1178 ° www.gel.com 3
List of current GEL Certifications as of 06 September 2006 State Alaska Arizona Arkansas California...
Colorado Connecticut Dept. of Navy EPA Florida/NELAP - -
Georgia Idaho Illinois Indiana Kansas Kentucky Maryland Massachusetts Michigan Nevada New Jersey New York North Carolina North Carolina Drinking W
.orth Dakota Oklahoma Pennsylvania Certification UST-062 AZ0668 88-0651 42D0904046 01 I5ICA.
GenEngLabs PH-0o69 NFESC 413 WG-15J1 E87 156 E87156 (FL/NELAP)
N/A 200029 C-SC-01 E-10332
/
90129 270 M-SCO12 9903 SC12 C02B 233............. I 45709 R-158 9904 68-48 5 I
South Carolina 10120001/10585001/10120002 Tennessee 02934-Texas TX213-2006A U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont N/A Virginia 00151 Washington C223 4
Chain of Custody And Supporting Documentation 5
Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Chain of Custody Form N.2006 -@6-/9-Connecticut Yankee Atomic Power Company Co.
362 Injun Hollow Road, East Hampton, CT 06424 J 71O544/
860-267-2556 1405440/
Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:
Comments:
Jack McCarthy 860-267-3924 Media Sample Container Code Type Size-Analytical Lab (Name, City, State):
Code
&Type General Engineering Laboratories Code 2040 Savage Road Charleston, SC 29407 ATT: Cheryl Jones (843-556-8171)
Priority: [] 30 D. E 14 D. 7] 7 D.
Other:
Sample Designation Date Time Comment, Preservation Lab Sample ID 9304-02-001F 8/21/06 U
TS G
BP X
- 9304-02-001FS 8/21/06 1 3 i TS G
BP X
9304-02-002F 8/21/06 lauy TS G
BP X
K 9304-02-003F 8/21/06 TS G
BP X
9304-02-004F 8/21/06 I0lo4T TS G
BP x
9304-02-004FS 8/21/06 TS G
BP X
O\\
9304-02-005F 8/21/06 1 ODS TS G
BP X
9304-02-006F 8/21/06 110-7 TS G
BP X
9304-02-007F 8/21/06 1 iao TS G
BP X
9304-02-008F 8/21/06 1V);(
TS G
BP x
NOTES: PO #: 002332 MSR #: 66 -/I 7 tV
[
LTP QA D Radwaste QA D Non QA Samples Shipped Via:
Internal Co tainer Z] Fed Ex Temp.: J4 Deg. C 0] Hand Custody Sealed?
Y 9-N El l) Reli ui, dBy(
l Date/Time
- 2) eceiv d By Date/Time Custody Seal Intact?
~t/-zq/ot tCj I S-v El~c
~Other
- 3) Relfnquished By Date/Time
- 4) Receive'ý By U Date/Time
-7 16c, 5"37 99o(#
YV N El Bill of Lading #
- 5) Relinquished By Date/Time
- 6) Received By Date/Time
Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-00 1 Major Chain of Custody Form N.20-00 Connecticut Yankee Atomic Power Company No. 2006-00507 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning
-Analyses Requested l'b-O U*
'On ly"'
Contact Name & Phone:
Comm**fies:"
Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)
General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0
843 556 8171. Attn. Cheryl Jones
"/)
Priority: D30 D. Z 14 D. [
7 D. 0 3D.
Container Sample Size-Sample Designation Date Time Media Type
&Type Comment, Preservation Lab sample ID Code Code Code 9304-02-009F L
TS G
BP X
9304-02-OIOF
- 1) I l d L
}"
TS G
BP X
9304-02-01IF
[,/?i/L
/IYI, TS G
BP X
9304-02-012F j
j/
TS G
BP X
9304-02-013F TS G
BP X
9304-02-014F T172 7
ULb' TS G
BP X
9304-02-01SF S/d t4fb
/lyl, TS G
BP x
VI~
4 I
1----+-~---l
+-~
I NOTES: PO #:002332 MSR: 06-t7q SSWP# NA Z LTP QA E] Radwaste QA D Non QA Samples Shipped Via:
Internal Container SFed ExTm.:
Dg D] ups D Hand Custody-Sealed?
YEV/ NO 0 I) Rer qui By Date/Time
- 2) ecei d By Date/Time
'.Cstody Seal oI~j/~.
j~o el~I~c Y
L[E Other Intact?..
quished By Date/Time
- 4) Receiv d By Date/Time 7'7, 5"1;7 9o1,"
Ye",
Bill of Lading #
- 5) Relinquished By Date/Time
- 6) Received By Date/Time
Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 1 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00509 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:
Comments:
Jack McCarthy 860-267-3924 Media Sample Container Code Type Size-Analytical Lab (Name, City, State):
Code
&Type Code On Site Counting Facility Priority: 1 30 D. M 14 D. 1] 7 D.
Other:
V_
Sample Designation Date Time Comment, Preservation Lab Sample ID 9304-02-016F 8/21/06 JL,2)*
TS G
1LM X
19304-02-017F 8/21/06 Y
-/3r TS G
1LM X
NOTES: PO #: 002332 MSR #:
[D Radwaste QA 11 Non QA Samples Shipped Via:
Internal Container El Fed Ex Temp.: '7/7 Deg. C D ups
[
Hand Custody Sealed?
Y 1-1 N E
- 1) Re*
-edRceive y
ate/Time Custody Seal Intact?
Re2 n
,0eu 2-a/i e
E] Other 3)Jlinquis ed By Date/Time
- 4) Received'1y Date/Time Bll't5"7_?7 of(,
Y D N
L n
Bill of Lading #
- 5) Relinquished By Date/Time
- 6) Received By Date/Time
Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SoW-OOI Figure 1. Sample Check-in List Date/Time Received':
tZ0 0
9 I~
5 SDG#:
>(
Work Order Number:
D054o5q A Shipping Container ID: 1 OQ6I 0
31 Chain of Custody#. 4CQI(-
9O
- 1.
Custody Seals ori shipping container intact?.*
Yes [,f No [ ]
- 2.
Custody Seals dated and signed?
Yesj [] No k].
- 3.
Chain-of-Custody record present?
Yes yrNo"°
.4.
Cooler temperature e
O 3
'C a_
- 5.
Vermiculite/packing materials is:
Wet [ J Dry t*
6.I Number of samples in shipping container:.
- 7.
Sample holding times exceeded?
Yes [
No []
.8.. Samples have:'
_...ztape
-hazard labels
. _2._::custody seals...
i appropriate'sample labels
- 9. Samples are-
" *iin good condition
-"_leaking
-broken
-have air bubbles
- 10.
Were any anomalies identified in sample receipt?
- 11.
- Description of anomalies (include sample numbers):
Yes
]No Telephoned to:
,./
By
.0,_
_By-
. -9
SAMPLE RECEIPT & REVIEW FORM 0
PM use only Client: ( *
%40A--
1);I SDG/ARCOC/Work Order:
(7/0,5 I Date Received.
Z) Pt PM(A) Review (ensure non-confor g items are resolved prior to signing): I Sample Receipt Criteria Comments/Qualifiers (Required for Non-Conforming is)
I Shipping containers received intact Circle Applicable: seals broken damaged container leaking con er other (describe) and sealed?
Samples requiring cold Circle Coolant #
ice bags blue ice ice none other describe) 2 preservation within (4 +/- 2 C)?
_Record preservation method.
3 Chain of custody documents included with shipment?
4 Sample containers intact and Circle Applicable: seals bro damaged container leaking container other (describe) sealed?
Samples requiring chemical Sample ID's co mners affected and observed pH:
5 preservation at proper pH?
6 VOA vials free of headspace Sam ID's and containers affected:
(defined as < 6mm bubble)?
Are Encore containers present?
7 (If yes, immediately deliver to VOA laboratory)
Samples received within holding 1
Id's and tests affected:
8time?
.... */
on COC ma ID's Sample ID's and containers affected:
on bottles?_________
-Date & time on C match date Sample ID's affected:
10 & time on boes?
Number "containers received Sample ID's affected:
11 mat number indicated on COC?
1 C form is properly signed in
- relinquished/received sections?
14 Air Bill,Tracking #'s, &
Additional Comments b la'n Q
w
"* 'RSO RAD Receipt #
-- *If> x2 area background is observed on samples identified as "non-Suspected Hazard Information S
Sa Ud I regulated/non-radioactive", contact the Radiation Safety group for further
_____________________fit investigation.
A RadiologicalClassification?
/
Maximum Counts Observed*:
ffl')
&.()
,t,4 T PCB Regulated?
Comments:
Shipped as DOT Hazardous C Material? If yes, contact Waste
/
Hazard Class Shipped:
Manager or ESH Manager.
UN#:
PM (or PMA) review of Hazard classification: _
Initials Date:
-A"o__ci d.t.I V
I
CONNECTICUT YANKEE RE: Soil PO# 002332 Work Order: 170543 SDG: MSR#06-1172 170543001 170543002 170543003 170543004 170543005 170543006 170543007 170543008 170543009 170543010 170543011 170543012 170543013 170543014 170543015 170543016 170543017 170543018 170543019 170543020 170543021 9304-0001-00IF 9304-0001-002F 9304-0001-002FS 9304-0001-003F 9304-0001-004F 9304-0001-005F 9304-0001-009F 9304-0001-OIOF 9304-0001-01OFS 9304-0001-01 IF 9304-0001-012F 9304-0001-014F 9304-0001-015F 9304-0001-016F 9304-0001-017F 9304-0001-018F 9304-0001-019F 9304-0001-020F 9304-0001-021F 9304-0001-008F 9304-0001-013F 11
RADIOLOGICAL ANALYSIS 12
Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)
Work Order 170544 Method/Analysis Information Product:
Alphaspec Am241, Cm, Solid ALL FSS Analytical Method:
DOE EML HASL-300, Am-05-RC Modified Prep Method:
Dry Soil Prep GL-RAD-A-021 Method:
Analytical Batch Number:
Prep Batch Number:
Dry Soil Prep GL-RAD-A-021 Batch Number:
Ash Soil Prep Dry Soil Prep 564247 563877 563875 Sample ID 170544018 170544019 1201173419 1201173420 1201173421 1201173422 Client ID 9304-0002-005F 9304-0002-008F Method Blank (MB) 170543020(9304-0001-008F) Sample Duplicate (DUP) 170543020(9304-0001-008F) Matrix Spike (MS)
Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
13
Quality Control (QCQ Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 170543020 (9304-0001-008F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Batch was cleaned-up and recounted due to Thorium interference.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Manual Integration No manual integrations were performed on data in this batch.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Qualifier Reason Analyte Sample X
Results may be biased high due to Thorium Americium-241 170544018 inteference in the sample.
170544019 1201173420 Curium-243/244 170544018 Method/Analysis Information 14
Product:
Alphaspec Pu, Solid-ALL FSS Analytical Method:
DOE EML HASL-300, Pu-I I-RC Modified Prep Method:
Dry Soil Prep GL-RAD-A-021 Method:
Analytical Batch Number:
Prep Batch Number:
Dry Soil Prep GL-RAD-A-021 Batch Number:
Ash Soil Prep Dry Soil Prep 564258 563877 563875 Sample ID 170544018 170544019 1201173423 1201173424 1201173425 1201173426 Client ID 9304-0002-005F 9304-0002-008F Method Blank (MB) 170543020(9304-0001-008F) Sample Duplicate (DUP) 170543020(9304-0001-008F) Matrix Spike (MS)
Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-011 REV# 14.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (OC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 170543020 (9304-0001-008F).
QC Information 15
All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Sample 1201173423 (MB) was recounted due to a negative result greater than three times the error.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Manual Integration No manual integrations were performed on data in this batch.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product:
Liquid Scint Pu241, Solid-ALL FSS DOE EML HASL-300, Pu-I I-RC Modified Analytical Method:
Prep Method:
Dry Soil Prep GL-RAD-A-021 Method:
Analytical Batch Number:
Prep Batch Number:
Dry Soil Prep GL-RAD-A-021 Batch Number:
Ash Soil Prep Dry Soil Prep 564259 563877 563875 16
Sample ID Client ID 170544018 9304-0002-005F 170544019 9304-0002-008F 1201173427 Method Blank (MB) 1201173428 170543020(9304-0001-008F) Sample Duplicate (DUP) 1201173429 170543020(9304-0001-008F) Matrix Spike (MS) 1201173430 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 170543020 (9304-0001-008F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from 17
referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Manual Integration No manual integrations were performed on data in this batch.
Additional Comments Additional comments were not required for this sample set.
Gualifier information Manual qualifiers were not required.
Method/Analysis Information Product:
Analytical Method:
Prep Method:
Analytical Batch Number:
Prep Batch Number:
Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived EML HASL 300, 4.5.2.3 Dry Soil Prep 563988 563875 18
Sample ID 170544001 170544002 170544003 170544004 170544005 170544006 170544007 170544008 170544009 170544010 170544011 170544012 170544013 170544014 170544015 170544016 170544017 170544018 170544019 1201172834 1201172835 1201172836 Client ID 9304-0002-001F 9304-0002-001 FS 9304-0002-002F 9304-0002-003F 9304-0002-004F 9304-0002-004FS 9304-0002-006F 9304-0002-007F 9304-0002-009F 9304-0002-01 OF 9304-0002-01 IF 9304-0002-012F 9304-0002-013F 9304-0002-014F 9304-0002-015F 9304-0002-016F 9304-0002-017F 9304-0002-005F 9304-0002-008F Method Blank (MB) 170543021(9304-0001-013F) Sample Duplicate (DUP)
Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 12.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Ouality Control (0C) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 170543021 (9304-0001-013F).
QC Information 19
All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments The duplicate and the sample 1201172835 (9304-0001-013F)did not meet the relative percent difference requirement for Bi-214 and Ra-226, but they do meet the relative error ratio requirement with a value of 1.79394.
Qualifier information Qualifier Reason Analyte Sample U'
UI U'
Data rejected due to high peak-width.
Data rejected due to interference.
Data rejected due to low abundance.
Bismuth-212 Europium-155 Cesium-134 170544007 170544014 170544015 170544002 170544005 170544006 170544007 170544009 170544012 170544013 170544014 170544018 170544003 Silver-108m 20
Method/Analysis Information Product:
GFPC, Sr90, solid-ALL FSS Analytical Method:
EPA 905.0 Modified Prep Method:
Dry Soil Prep GL-RAD-A-021 Method:
Analytical Batch Number:
Prep Batch Number:
Dry Soil Prep GL-RAD-A-021 Batch Number:
Ash Soil Prep Dry Soil Prep 564153 563877 563875 Sample ID 170544018 170544019 1201173179 1201173180 1201173181 1201173182 Client ID 9304-0002-005F 9304-0002-008F Method Blank (MB) 170544018(9304-0002-005F) Sample Duplicate (DUP) 170544018(9304-0002-005F) Matrix Spike (MS)
Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (0C) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC 21
The following sample was used for QC: 170544018 (9304-0002-005F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product:
Liquid Scint Tc99, Solid-ALL FSS Analytical Method:
Analytical Batch Number:
Sample ID 170544018 170544019 1201173840 1201173841 1201173842 1201173843 DOE EML HASL-300, Tc-02-RC Modified 564445 Client ID 9304-0002-005F 9304-0002-008F Method Blank (MB) 170544018(9304-0002-005F) Sample Duplicate (DUP) 170544018(9304-0002-005F) Matrix Spike (MS)
Laboratory Control Sample (LCS) 22
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (Q0 Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 170544018 (9304-0002-005F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
23
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product:
Liquid Scint Fe55, Solid-ALL FSS Analytical Method:
DOE RESL Fe-1, Modified Prep Method:
Dry Soil Prep GL-RAD-A-021 Method:
Analytical Batch Number:
Prep Batch Number:
Dry Soil Prep GL-RAD-A-021 Batch Number:
Ash Soil Prep Dry Soil Prep 564451 563877 563875 Sample ID 170544018 170544019 1201173858 1201173859 1201173860 1201173861 Client ID 9304-0002-005F 9304-0002-008F Method Blank (MB) 170543020(9304-0001-008F) Sample Duplicate (DUP) 170543020(9304-0001-008F) Matrix Spike (MS)
Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (OC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
24
Designated QC The following sample was used for QC: 170543020 (9304-0001-008F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product:
Liquid Scint Ni63, Solid-ALL FSS Analytical Method:
DOE RESL Ni-1, Modified Prep Method:
Dry Soil Prep GL-RAD-A-021 Method:
Analytical Batch Number:
Prep Batch Number:
Dry Soil Prep GL-RAD-A-021 Batch Number:
Ash Soil Prep Dry Soil Prep 564452 563877 563875 25
Sample ID Client ID 170544018 9304-0002-005F 170544019 9304-0002-008F 1201173872 Method Blank (MB) 1201173873 170543020(9304-0001-008F) Sample Duplicate (DUP) 1201173874 170543020(9304-0001-008F) Matrix Spike (MS) 1201173875 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 170543020 (9304-0001-008F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from 26
referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product:
Analytical Method:
Analytical Batch Number:
Sample ID 170544018 170544019 1201173844 1201173845 1201173846 1201173847 LSC, Tritium Dist, Solid-HTD2,ALL FSS EPA 906.0 Modified 564447 Client ID 9304-0002-005F 9304-0002-008F Method Blank (MB) 170544018(9304-0002-005F) Sample Duplicate (DUP) 170544018(9304-0002-005F) Matrix Spike (MS)
Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 13.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
27
Designated QC The following sample was used for QC: 170544018 (9304-0002-005F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Samples 1201173846 (9304-0002-005F) and 1201173847 (LCS) were recounted due to low/high recovery.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. The following NCR was generated for this SDG:
NCR 356177 was generated due to Container scanning event for custody missed. 1. Container scanning event for custody missed: The analyst did not scan the samples intot he batch prior to analysis, however the samples did remain in their custody at all times. 1. The error has been corrected and the analyst has been instructed on proper scanning procedures. Reporting results Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product:
Liquid Scint C14, Solid AI1,FSS Analytical Method:
EPA EERF C-01 Modified Analytical Batch Number:
564449 28
Sample ID Client ID 170544018 9304-0002-005F 170544019 9304-0002-008F 1201173848 Method Blank (MB) 1201173849 170544019(9304-0002-008F) Sample Duplicate (DUP) 1201173850 170544019(9304-0002-008F) Matrix Spike (MS) 1201173851 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 170544019 (9304-0002-008F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Sample 1201173849 (9304-0002-008F) was recounted due to a negative result greater than three times the error.
Miscellaneous Information:
NCR Documentation 29
Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Oualifier information Manual qualifiers were not required.
Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.
Review Validation:
GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.
The following data validator verified the information presented in this case narrative:
Reviewer/Date:
U
.91"4 30
General Engineering Laboratories Form GEL-NCR Rev. 06/05 NCR Report No.:
356177 Revision No.:
1 COMPANY - WIDE NONCONFORMANCE REPORT Mo.Day Yr.
Division:
Quality Criteria:
Type:
08-SEP-06 Radiochemistry Specifications Process Instrument Type:
Test / Method:
Matrix Type:
Client Code:
LSC EPA 906.0 Modified Solid YANK Batch ID:
Sample Numbers:
564447 See Below Potentially affected work order(s)(SDG): 170543(MSR#06-1172),170544(MSR#06-1174),170683 Application Issues:
Container scanning event for custody missed Specification and Requirements NRG Disposition:
Nonconformance
Description:
- 1. Container scanning event for custody missed: The analyst did not scan
- 1. The error has been corrected and the analyst has been instructed on the samples intot he batch prior to analysis, however the samples did proper scanning procedures. Reporting results remain in their custody at all times.
Originator's Name:
Kenshalla Oston Quality Review:
Data Validator/Group Leader:
Melanie Aycock 08-SEP-06 08-SEP-06 Director:
Page 1 31
SAMPLE DATA
SUMMARY
32
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.
Client SDG: MSR#06-1174 GEL Work Order: 170544 The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier ND The analyte concentration is not detected above the detection limit.
The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.
Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.
This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.
Reviewed by 33
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date:
September 15, 2006 Client Sample ID:
9304-0002-OOIF Project:
YANK01204 Sample ID:
170544001 Client ID:
YANK001 Matrix:
Soil Vol. Recv.:
Collect Date:
21-AUG-06 Receive Date:
30-AUG-06 Collector:
Client Moisture:
5.39%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.675
+/-0.203 0.0819
+/-0.203 0.164 pCi/g MJH1 09/10/06 1502 563988 Americium-241 U
0.0358
+/-0.0434 0.0307 +/-0.0434 0.0614 pCi/g Bismuth-212 0.444
+/-0.285 0.171
+/-0.285 0.342 pCi/g Bismuth-214 0.597
+/-0.116 0.0419
+/-0.116 0.0838 pCi/g Cesium-134 U
0.024
+/-0.0298 0.0277 +/-0.0298 0.0553 pCi/g Cesium-137 U
0.0159
+/-0.0266 0.0245 +/-0.0266 0.049 pCi/g Cobalt-60 U
0.00881
+/-0.0345 0.0259 +/-0.0345 0.0518 pCi/g Europium-152 U
0.0442
+/-0.0483 0.0481 +/-0.0483 0.0961 pCi/g Europium-154 U
0.0239
+/-0.087 0.0755
+/-0.087 0.151 pCi/g Europium-155 U
0.0074
+/-0.0551 0.0494 +/-0.0551 0.0987 pCi/g Lead-212 0.693
+/-0.085 0.0295
+/-0.085 0.059 pCi/g Lead-214 0.643
+/-0.102 0.039
+/-0.102 0.078 pCi/g Manganese-54 U -0.00297
+/-0.0284 0.0209 +/-0.0284 0.0418 pCi/g Niobium-94 U
-0.0154
+/-0.0238 0.0198 +/-0.0238 0.0396 pCi/g Potassium-40 10.9
+/-1.04 0.234
+/-1.04 0.468 pCi/g Radium-226 0.597
+/-0.116 0.0419
+/-0.116 0.0838 pCi/g Silver-108m U
-0.0115
+/-0.0218 0.0182 +/-0.0218 0.0365 pCi/g Thallium-208 0.250
+/-0.0482 0.0195 +/-0.0482 0.039 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 08/30/06 1546 563875 The following Analytical Methods were performed Method Description I
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 34
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:
September 15, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9304-0002-OOIF Proiect:
YANK01204 Sample ID:
170544001 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch IN Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
35
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd
Contact:
Project:
East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: September 15, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9304-0002-001FS 170544002 Soil 21 -AUG-06 30-AUG-06 Client 5.13%
Project:
Client ID:
Vol. Recv.:
YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.678
+/-0.158 0.056
+/-0.158 0.112 pCi/g MJHI 09/10/06 1658 563988 Americium-241 U
0.0182
+/-0.0696 0.0564 +/-0.0696 0.113 pCi/g Bismuth-212 0.506
+/-0.234 0.129
+/-0.234 0.258 pCi/g Bismuth-214 0.572
+/-0.096 0.0306
+/-0.096 0.0612 pCi/g Cesium-134 UI 0.00
+/-0.0279 0.0205 +/-0.0279 0.0409 pCi/g Cesium-137 U
0.0245
+/-0.0316 0.0187 +/-0.0316 0.0373 pCi/g Cobalt-60 U
0.0139
+/-0.0196 0.0178 +/-0.0196 0.0356 pCi/g Europium-152 U
0.0427
+/-0.078 0.0434
+/-0.078 0.0868 pCi/g Europium-154 U
-0.0549
+/-0.0651 0.0494 +/-0.0651 0.0988 pCi/g Europium-155 U
0.0421
+/-0.0556 0.0508 +/-0.0556 0.101 pCi/g Lead-212 0.707
+/-0.0794 0.0271 +/-0.0794 0.0542 pCi/g Lead-214 0.610
+/-0.0923 0.0321 +/-0.0923 0.0641 pCi/g Manganese-54 U -0.00669
+/-0.0195 0.0165 +/-0.0195 0.0329 pCi/g Niobium-94 U -0.00231
+/-0.0176 0.0153 +/-0.0176 0.0306 pCi/g Potassium-40 11.4
+/-1.03 0.171
+/-1.03 0.341 pCi/g Radium-226 0.572
+/-0.096 0.0306
+/-0.096 0.0612 pCi/g Silver-108m U
-0.0138
+/-0.017 0.014
+/-0.017 0.0279 pCi/g Thallium-208 0.236
+/-0.0442 0.0142 +/-0.0442 0.0284 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 08/30/06 1546 563875 The following Analytical Methods were performed Method Description I
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
- g A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 36
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:
September 15, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9304-0002-OOIFS Project:
YANK01204 Sample ID:
170544002 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%
Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
37
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd
Contact:
Project:
East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: September 15, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9304-0002-002F 170544003 Soil 21-AUG-06 30-AUG-06 Client 5.38%
Proiect:
Client ID:
Vol. Recv.:
YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.818
+/-0.198 0.0582
+/-0.198 0.116 pCi/g MJHI 09/11/06 0828 563988 Americium-241 U 0.000923
+/-0.0732 0.058 +/-0.0732 0.116 pCi/g Bismuth-212 0.483
+/-0.303 0.133
+/-0.303 0.265 pCi/g Bismuth-214 0.612
+/-0.0992 0.034 +/-0.0992 0.0679 pCi/g Cesium-134 U
0.018
+/-0.0233 0.0213 +/-0.0233 0.0426 pCi/g Cesium-137 U -0.00836
+/-0.0227 0.0185 +/-0.0227 0.037 pCi/g Cobalt-60 U
0.013
+/-0.0232 0.0183 +/-0.0232 0.0365 pCi/g Europium-152 U
0.0263
+/-0.0662 0.0491
+/-0.0662 0.098 pCi/g Europium-154 U -0.00379
+/-0.0789 0.0608 +/-0.0789 0.121 pCi/g Europium-155 U
0.0654
+/-0.0695 0.0487 +/-0.0695 0.0973 pCi/g Lead-212 0.686
+/-0.0817 0.0278 +/-0.0817 0.0555 pCi/g Lead-214 0.648
+/-0.0951 0.035 +/-0.0951 0.070 pCi/g Manganese-54 U
0.0036
+/-0.0219 0.0192 +/-0.0219 0.0383 pCi/g Niobium-94 U
0.0118
+/-0.0191 0.0174 +/-0.0191 0.0348 pCi/g Potassium-40 11.4
+/-1.08 0.139
+/-1.08 0.278 pCi/g Radium-226 0.612
+/-0.0992 0.034 +/-0.0992 0.0679 pCi/g Silver-108m UI 0.00
+/-0.0296 0.0152 +/-0.0296 0.0304 pCi/g Thallium-208 0.230
+/-0.0438 0.0162 +/-0.0438 0.0323 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 08/30/06 1546 563875 The following Analytical Methods were performed Method Description I
EML HASL 300,4.5.2.3 Notes:
The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 38
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407- (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 15, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9304-0002-002F Project:
YANK01204 Sample ID:
170544003 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1 Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
39
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: September 15, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9304-0002-003F 170544004 Soil 21-AUG-06 30-AUG-06 Client 3.93%
Project:
Client ID:
Vol. Recv.:
YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch N' Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.753
+/-0.140 0.0503
+/-0.140 0.111 pCi/g MJHl 09/11/06 0927 563988 Americium-241 U
0.0553
+/-0.0789 0.0697 +/-0.0789 0.145 pCi/g Bismuth-212 0.476
+/-0.226 0.115
+/-0.226 0.251 pCi/g Bismuth-214 0.466
+/-0.0939 0.0318 +/-0.0939 0.0679 pCi/g Cesium-134 U
0.0381
+/-0.0291 0.0215 +/-0.0291 0.0461 pCi/g Cesium-137 U -0.00316
+/-0.0183 0.0156 +/-0.0183 0.0338 pCi/g Cobalt-60 U -7.740E-
+/-0.0179 0.0153 +/-0.0179 0.0348 pCi/g 05 Europium-152 U
0.00612
+/-0.0483 0.0414 +/-0.0483 0.0876 pCi/g Europium-154 U
0.0129
+/-0.0639 0.0564 +/-0.0639 0.124 pCi/g Europium-155 U 0.000165
+/-0.0506 0.0464 +/-0.0506 0.0964 pCi/g Lead-212 0.609
+/-0.0573 0.0246 +/-0.0573 0.0514 pCi/g Lead-214 0.607
+/-0.0855 0.0303 +/-0.0855 0.064 pCi/g Manganese-54 U
0.0223
+/-0.0179 0.0173 +/-0.0179 0.0373 pCi/g Niobium-94 U -0.00811
+/-0.0164 0.0135 +/-0.0164 0.0293 pCi/g Potassium-40 11.6
+/-0.913 0.135
+/-0.913 0.311 pCi/g Radium-226 0.466
+/-0.0939 0.0318 +/-0.0939 0.0679 pCi/g Silver-108m U -0.00366
+/-0.0149 0.0131 +/-0.0149 0.028 pCi/g Thallium-208 0.177
+/-0.0462 0.0171 +/-0.0462 0.0366 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI1 08/30/06 1546 563875 The following Analytical Methods were performed Method Description I
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 40
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 15, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9304-0002-003F Project:
YANK01204 Sample ID:
170544004 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A*
Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
41
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date:
September 15, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9304-0002-004F 170544005 Soil 21-AUG-06 30-AUG-06 Client 3.21%
Project:
Client ID:
Vol. Recv.:
YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1I Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.758
+/-0.170 0.0623
+/-0.170 0.135 pCi/g MJHI 09/11/06 1024 563988 Americium-241 U
0.0922
+/-0.106 0.0902
+/-0.106 0.187 pCi/g Bismuth-212 0.506
+/-0.275 0.121
+/-0.275 0.263 pCi/g Bismuth-214 0.552
+/-0,0891 0.0269 +/-0.0891 0.058 pCi/g Cesium-134 UI 0.00
+/-0.0271 0.0219 +/-0.0271 0.0469 pCi/g Cesium-137 U
0.00831
+/-0.0196 0.0175 +/-0.0196 0.0375 pCi/g Cobalt-60 U
0.0253
+/-0.0222 0.0202 +/-0.0222 0.0445 pCi/g Europium-152 U
-0.0134
+/-0.0538 0.045 +/-0.0538 0.0949 pCi/g Europium-154 U
0.0738
+/-0.0451 0.0522 +/-0.0451 0.116 pCi/g Europium-155 U
0.0703
+/-0.0546 0.0535 +/-0.0546 0.111 pCi/g Lead-212 0.652
+/-0.0609 0.0259 +/-0.0609 0.0542 pCi/g Lead-214 0.761
+/-0.0968 0.030 +/-0.0968 0.0635 pCi/g Manganese-54 U -0.00241
+/-0.0206 0.0171 +/-0.0206 0.0369 pCi/g Niobium-94 U
0.0106
+/-0.0173 0.0156 +/-0.0173 0.0335 pCi/g Potassium-40 11.0
+/-0.854 0.129
+/-0.854 0.300 pCi/g Radium-226 0.552
+/-0.0891 0.0269 +/-0.0891 0.058 pCi/g Silver-108m U
-0.0156
+/-0.0165 0.0137 +/-0.0165 0.0294 pCi/g Thallium-208 0.187
+/-0.0409 0.0158 +/-0.0409 0.0339 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 08/30/06 1546 563875 The following Analytical Methods were performed Method Description I
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 42
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:
September 15, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9304-0002-004F Proiect:
YANK01204 Sample ID:
170544005 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%
Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
43
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company :
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: September 15, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9304-0002-004FS 170544006 Soil 21-AUG-06 30-AUG-06 Client 3.03%
Proiect:
Client ID:
Vol. Recv.:
YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.574
+/-0.147 0.0692
+/-0.147 0.148 pCi/g MJH1 09/11/06 1024 563988 Americium-241 U
0.0183
+/-0.0795 0.0674 +/-0.0795 0.140 pCi/g Bismuth-212 0.309
+/-0.290 0.126
+/-0.290 0.270 pCi/g Bismuth-214 0.497
+/-0.0896 0.0293 +/-0.0896 0.0625 pCi/g Cesium-134 UI 0.00
+/-0.0299 0.0215 +/-0.0299 0.0456 pCi/g Cesium-137 U -0.00249
+/-0.0201 0.0174 +/-0.0201 0.037 pCi/g Cobalt-60 U
0.00133
+/-0.0188 0.0161 +/-0.0188 0.0359 pCi/g Europium-152 U
0.0114
+/-0.0518 0.0461 +/-0.0518 0.0967 pCi/g Europium-154 U
0.00293
+/-0.0637 0.0546 +/-0.0637 0.119 pCi/g Europium-155 U
0.0334
+/-0.055 0.0507
+/-0.055 0.105 pCi/g Lead-212 0.665
+/-0.0616 0.0256 +/-0.0616 0.0532 pCi/g Lead-214 0.609
+/-0.0859 0.0303 +/-0.0859 0.0639 pCi/g Manganese-54 U -0.00658
+/-0.0205 0.017 +/-0.0205 0.0365 pCi/g Niobium-94 U
-0.0153
+/-0.0173 0.0139 +/-0.0173 0.0298 pCi/g Potassium-40 10.3
+/-0.814 0.151
+/-0.814 0.339 pCi/g Radium-226 0.497
+/-0.0896 0.0293 +/-0.0896 0.0625 pCi/g Silver-108m U
0.0065
+/-0.0163 0.0144 +/-0.0163 0.0306 pCi/g Thallium-208 0.178
+/-0.0427 0.0175 +/-0.0427 0.0371 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 08/30/06 1546 563875 The following Analytical Methods were performed Method Description I
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 44
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 15, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9304-0002-004FS Project:
YANKO 1204 Sample ID:
170544006 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
45
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date:
September 15, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9304-0002-006F 170544007 Soil 21-AUG-06 30-AUG-06 Client 4.15%
Proiect:
Client ID:
Vol. Recv.:
YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.619
+/-0.171 0.0633
+/-0.171 0.137 pCi/g MJHI 09/11/06 1025 563988 Americium-241 U
-0.0339
+/-0.085 0.0741
+/-0.085 0.154 pCi/g Bismuth-212 UI 0.00
+/-0.302 0.123
+/-0.302 0.266 pCi/g Bismuth-214 0.477
+/-0,0795 0.0367 +/-0.0795 0.078 pCi/g Cesium-134 UI 0.00
+/-0.0469 0.0218 +/-0.0469 0.0468 pCi/g Cesium-137 U
0.00955
+/-0.0215 0.0195 +/-0.0215 0.0416 pCi/g Cobalt-60 U
0.00527
+/-0.0216 0.0192 +/-0.0216 0.0425 pCi/g Europium-152 U
-0.0287
+/-0.0563 0.0471 +/-0.0563 0.0993 pCi/g Europium-154 U
-0.0554
+/-0.0564 0.042 +/-0.0564 0.0953 pCi/g Europium-155 U
0.00655
+/-0.0541 0.0516 +/-0.0541 0.107 pCi/g Lead-212 0.641
+/-0.0603 0.0275 +/-0.0603 0.0573 pCi/g Lead-214 0.660
+/-0.0925 0.0338 +/-0.0925 0.0712 pCi/g Manganese-54 U
0.00406
+/-0.0232 0.0178 +/-0.0232 0.0385 pCi/g Niobium-94 U
0.0166
+/-0.0221 0.0153 +/-0.0221 0.0329 pCi/g Potassium-40 11.3
+/-0.916 0.152
+/-0.916 0.346 pCi/g Radium-226 0.477
+/-0.0795 0.0367 +/-0.0795 0.078 pCi/g Silver-108m U -0.00541
+/-0.0191 0.0159 +/-0.0191 0.0337 pCi/g Thallium-208 0.228
+/-0.0414 0.018 +/-0.0414 0.0385 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 08/30/06 1546 563875 The following Analytical Methods were performed Method Description I
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 46
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 15, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9304-0002-006F Proiect:
YANK01204 Sample ID:
170544007 Client ID:
YANK00I Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
47
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: September 15, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9304-0002-007F 170544008 Soil 21-AUG-06 30-AUG-06 Client 4.26%
Project:
Client ID:
Vol. Recv.:
YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.611
+/-0.138 0.061
+/-0.138 0.132 pCi/g MJHI 09/11/06 1026 563988 Americium-241 U
0.0231
+/-0.104 0.0713
+/-0.104 0.148 pCi/g Bismuth-212 0.351
+/-0.184 0.141
+/-0.184 0.302 pCi/g Bismuth-214 0.502
+/-0.0794 0.0338 +/-0.0794 0.0717 pCi/g Cesium-134 U
0.0371
+/-0.0272 0.0215 +/-0.0272 0.0459 pCi/g Cesium-I 37 U
0.0168
+/-0.0266 0.0178 +/-0.0266 0.0381 pCi/g Cobalt-60 U -0.00686
+/-0.0214 0.0173 +/-0.0214 0.0385 pCi/g Europium-152 U
-0.0104
+/-0.0497 0.0431 +/-0.0497 0.0909 pCi/g Europium-154 U
-0.014
+/-0.065 0.0539
+/-0.065 0.118 pCi/g Europium-155 U
0.0129
+/-0.054 0.0493
+/-0.054 0.102 pCi/g Lead-212 0.668
+/-0.0589 0.0242 +/-0.0589 0.0506 pCi/g Lead-214 0.519
+/-0.0803 0.0312 +/-0.0803 0.0658 pCi/g Manganese-54 U
0.0134
+/-0.0217 0.0195 +/-0.0217 0.0416 pCi/g Niobium-94 U
-0.015
+/-0.0196 0.016 +/-0.0196 0.0341 pCi/g Potassium-40 10.4
+/-0.868 0.169
+/-0.868 0.376 pCi/g Radium-226 0.502
+/-0.0794 0.0338 +/-0.0794 0.0717 pCi/g Silver-108m U -0.00476
+/-0.0175 0.0148 +/-0.0175 0.0313 pCi/g Thallium-208 0.170
+/-0.0567 0.0155 +/-0.0567 0.0331 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 08/30/06 1546 563875 The following Analytical Methods were performed Method Description I
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 48
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 15, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9304-0002-007F Proiect:
YANK01204 Sample ID:
170544008 Client ID:
YANKOO Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%
Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
49
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date:
September 15, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9304-0002-009F 170544009 Soil 21 -AUG-06 30-AUG-06 Client 4.23%
Project:
Client ID:
Vol. Recv.:
YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1\\
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.04
+/-0.171 0.0603
+/-0.171 0.130 pCi/g MJHI 09/11/06 1026 563988 Americium-241 U -0.00988
+/-0.0968 0.0825 +/-0.0968 0.170 pCi/g Bismuth-212 0.588
+/-0.225 0.138
+/-0.225 0.294 pCi/g Bismuth-214 0.690
+/-0.089 0.0307
+/-0.089 0.0655 pCi/g Cesium-134 UI 0.00
+/-0.0287 0.0239 +/-0.0287 0.0506 pCi/g Cesium-137 U -0.00814
+/-0.0216 0.018 +/-0.0216 0.0384 pCi/g Cobalt-60 U -0.00282
+/-0.0227 0.0191 +/-0.0227 0.0419 pCi/g Europium-152 U
-0.0135
+/-0.0538 0.0483 +/-0.0538 0.101 pCi/g Europium-154 U
-0.059
+/-0.0672 0.0519 +/-0.0672 0.114 pCi/g Europium-155 U
0.0604
+/-0.0587 0.0561 +/-0.0587 0.116 pCi/g Lead-212 1.00
+/-0.0664 0.0255 +/-0.0664 0.0531 pCi/g Lead-214 0.803
+/-0.0888 0.0337 +/-0.0888 0.0708 pCi/g Manganese-54 U
0.030
+/-0.0272 0.0183 +/-0.0272 0.0392 pCi/g Niobium-94 U
0.0119
+/-0.0173 0.0157 +/-0.0173 0.0335 pCi/g Potassium-40 17.0
+/-1.07 0.153
+/-1.07 0.344 pCi/g Radium-226 0.690
+/-0.089 0.0307
+/-0.089 0.0655 pCi/g Silver-108m U
-0.011
+/-0.017 0.0145
+/-0.017 0.0309 pCi/g Thallium-208 0.337
+/-0.0483 0.017 +/-0.0483 0.0361 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 08/30/06 1546 563875 The following Analytical Methods were performed Method Description I
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 50
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 15, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9304-0002-009F Project:
YANK01204 Sample ID:
170544009 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%
Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
51
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: September 15, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9304-0002-01OF 170544010 Soil 21-AUG-06 30-AUG-06 Client 5.58%
Project:
Client ID:
Vol. Recv.:
YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.921
+/-0.221 0.0758
+/-0.221 0.161 pCi/g MJHI 09/11/06 1027 563988 Americium-241 U
0.0632
+/-0.150 0.0925
+/-0.150 0.190 pCi/g Bismuth-212 0.632
+/-0.394 0,154
+/-0.394 0.326 pCi/g B3ismuth-214 0.726
+/-0.0865 0.0364 +/-0.0865 0.0769 pCi/g Cesium-134 U
0.0179
+/-0.0305 0.0255 +/-0.0305 0.0538 pCi/g Cesium-137 U -0.00218
+/-0.0238 0.0206 +/-0.0238 0.0436 pCi/g Cobalt-60 U -0.00271
+/-0.0225 0.0183 +/-0.0225 0.0405 pCi/g Europium-152 U
0.0279
+/-0.0609 0.0535 +/-0.0609 0.112 pCi/g Europium-154 U
-0.0123
+/-0.103 0.0721
+/-0.103 0.155 pCi/g Europium-155 U
0.105
+/-0.0774 0.0629 +/-0.0774 0.129 pCi/g Lead-212 1.07
+/-0.0714 0.031 +/-0.0714 0.0641 pCi/g Lead-214 0.767
+/-0.0815 0.0404 +/-0.0815 0.0841 pCi/g Manganese-54 U
0.00481
+/-0.0236 0.0205 +/-0.0236 0.0437 pCi/g Niobium-94 U -0.00717
+/-0.0229 0.0194 +/-0.0229 0.041 pCi/g Potassium-40 18.2
+/-1.10 0.180
+/-1.10 0.398 pCi/g Radium-226 0.726
+/-0.0865 0.0364 +/-0.0865 0.0769 pCi/g Silver-108m U 0.000781
+/-0.021 0.0178
+/-0.021 0.0374 pCi/g Thallium-208 0.326
+/-0.0511 0.0202 +/-0.0511 0.0426 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 08/30/06 1546 563875 The following Analytical Methods were performed Method Description I
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 52
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 15, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9304-0002-OIOF Proiect:
YANK01204 Sample ID:
170544010 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1l Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
53
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analyvis Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date:
September 15, 2006 Client Sample ID:
9304-0002-01 IF Project:
YANK01204 Sample ID:
170544011 Client ID:
YANK001 Matrix:
Soil Vol. Recv.:
Collect Date:
21-AUG-06 Receive Date:
30-AUG-06 Collector:
Client Moisture:
3.94%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1 Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.08
+/-0.154 0.0509
+/-0.154 0.108 pCi/g MJH1 09/11/06 1027 563988 Americium-241 U
-0.0745
+/-0.139 0.0909
+/-0.139 0.188 pCi/g Bismuth-212 0.669
+/-0.219 0.110
+1-0.219 0.233 pCi/g Bismuth-214 0.630
+/-0.0788 0.0285 +/-0.0788 0.060 pCi/g Cesium-134 U
0.0357
+/-0.0311 0.0201
+/-0.0311 0.042 pCi/g Cesium-137 U
0.00279
+/-0.0196 0.0165 +/-0.0196 0.0346 pCi/g Cobalt-60 U -0.00276
+/-0.0182 0.0153 +/-0.0182 0.0332 pCi/g Europium-152 U
0.00275
+/-0.0446 0.0396 +/-0.0446 0.0828 pCi/g Europium-154 U -0.00394
+/-0.0583 0.0499 +/-0.0583 0.107 pCi/g Europium-155 U
0.0531
+/-0.0588 0.0549 +/-0.0588 0.113 pCi/g Lead-212 0.969
+/-0.0598 0.0246 +/-0.0598 0.0508 pCi/g Lead-214 0.753
+/-0.0824 0.0251
+/-0.0824 0.0527 pCi/g Manganese-54 U
0.0227
+/-0.0244 0.0149 +/-0.0244 0.0315 pCi/g Niobium-94 U
0.00322
+/-0.016 0.0142
+/-0.016 0.0298 pCi/g Potassium-40 17.6
+/-0.830 0.122
+/-0.830 0.268 pCi/g Radium-226 0.630
+/-0.0788 0.0285 +/-0.0788 0.060 pCi/g Silver-108m U
0.00513
+/-0.0157 0.0139 +/-0.0157 0.029 pCi/g Thallium-208 0.319
+/-0.038 0.0146
+/-0.038 0.0307 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 08/30/06 1546 563875 The following Analytical Methods were performed Method Description I
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 54
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:
September 15, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9304-0002-01IF Project:
YANK01204 Sample ID:
170544011 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%
Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UL Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
55
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date:
September 15, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9304-0002-012F 170544012 Soil 21-AUG-06 30-AUG-06 Client 5.14%
Proiect:
Client ID:
Vol. Recv.:
YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch IN Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.623
+/-0.185 0.042
+/-0.185 0.0898 pCi/g MJHI 09/11/06 1029 563988 Americium-241 U
0.0102
+/-0.0652 0.0544 +/-0.0652 0.112 pCi/g Bismuth-212 0.659
+/-0.223 0.0953
+/-0.223 0.203 pCi/g Bismuth-214 0.659
+/-0.086 0.0248
+/-0.086 0.0521 pCi/g Cesium-134 UI 0.00
+/-0.0289 0.0169 +/-0.0289 0.0354 pCi/g Cesium-137 U
0.0107
+/-0.0165 0.0144 +/-0.0165 0.0303 pCi/g Cobalt-60 U
0.0242
+/-0.0158 0.0137 +/-0.0158 0.0295 pCi/g Europium-152 U -0.00833
+/-0.0457 0.0351 +/-0.0457 0.0733 pCi/g Europium-154 U
-0.0139
+/-0.0503 0.0408 +/-0.0503 0.0875 pCi/g Europium-155 U
0.00435
+/-0.049 0.0439
+/-0.049 0.0905 pCi/g Lead-212 0.683
+/-0.0495 0.0217 +/-0.0495 0.0449 pCi/g Lead-214 0.662
+/-0.0725 0.0254 +/-0.0725 0.053 pCi/g Manganese-54 U
0.0123
+/-0.0166 0,0151 +/-0.0166 0.0317 pCi/g Niobium-94 U
0.00425
+/-0.0142 0,0127 +/-0.0142 0.0268 pCi/g Potassium-40 12.7
+/-0.722 0.127
+/-0.722 0.276 pCi/g Radium-226 0.659
+/-0.086 0.0248
+/-0.086 0.0521 pCi/g Silver-108m U -0.00212
+/-0.0134 0.0116 +/-0.0134 0.0243 pCi/g Thallium-208 0.264
+/-0.0342 0.0121 +/-0.0342 0.0255 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 08/30/06 1546 563875 The following Analytical Methods were performed Method Description I
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 56
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 15, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9304-0002-012F Project:
YANK01204 Sample ID:
170544012 Client ID:
YANKOOI Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%
Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
57
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: September 15, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9304-0002-013F 170544013 Soil 21-AUG-06 30-AUG-06 Client 3.94%
Project:
Client ID:
Vol. Recv.:
YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.747
+/-0.185 0.0859
+/-0.185 0.183 pCi/g MJHI 09/11/06 1039 563988 Americium-241 U
0.0204
+/-0.0351 0.0319 +/-0.0351 0.0655 pCi/g Bismuth-212 U
0.352
+/-0.306 0.179
+/-0.306 0.379 pCi/g Bismuth-214 0.586
+/-0.148 0.0447
+/-0.148 0.0941 pCi/g Cesium-134 UI 0.00
+/-0.0456 0.0303 +/-0.0456 0.0638 pCi/g Cesium-137 U
0.0438
+/-0.0358 0.0235 +/-0.0358 0.0497 pCi/g Cobalt-60 U
0.0222
+/-0.0284 0.0257 +/-0.0284 0.0557 pCi/g Europium-152 U
-0.0238
+/-0.0656 0.0546 +/-0.0656 0.114 pCi/g Europium-154 U
-0.0278
+/-0.0864 0.0704 +/-0.0864 0.152 pCi/g Europium-155 U
0.0512
+/-0.075 0.0485
+/-0,075 0.100 pCi/g Lead-212 0.582
+/-0.0781 0.0395 +/-0.0781 0.0814 pCi/g Lead-214 0.671
+/-0.0942 0.0388 +/-0.0942 0.0813 pCi/g Manganese-54 U
0.0267
+/-0.0273 0.0246 +/-0.0273 0.0521 pCi/g Niobium-94 U-0.000123
+/-0.0243 0.0207 +/-0.0243 0.0438 pCi/g Potassium-40 12.8
+/-1.03 0.215
+/-1.03 0.471 pCi/g Radium-226 0.586
+/-0.148 0.0447
+/-0.148 0.0941 pCi/g Silver-108m U -0.00186
+/-0.0214 0.019 +/-0.0214 0.040 pCi/g Thallium-208 0,254
+/-0.0532 0.0232 +/-0.0532 0.049 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 08/30/06 1546 563875 The following Analytical Methods were performed Method Description EML HASL 300,4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 58
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:
September 15, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9304-0002-013F Project:
YANKO 1204 Sample ID:
170544013 Client ID:
YANKOOI Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%
Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
59
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date: September 15, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9304-0002-014F 170544014 Soil 21-AUG-06 30-AUG-06 Client 3.65%
Project:
Client ID:
Vol. Recv.:
YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.978
+/-0.176 0.0653
+/-0.176 0.141 pCi/g MJH1 09/11/06 1040 563988 Americium-241 U
0.00324
+/-0.030 0.0241
+/-0.030 0.0497 pCi/g Bismuth-212 0.591
+/-0.302 0.145
+/-0.302 0.310 pCi/g Bismuth-214 0.681
+/-0.0898 0.0352 +/-0.0898 0.0747 pCi/g Cesium-134 UI 0.00
+/-0.0469 0.0262 +/-0.0469 0.0553 pCi/g Cesium-137 U
0.024
+/-0.0255 0.019 +/-0.0255 0.0406 pCi/g Cobalt-60 U
0.012
+/-0.0241 0.0213 +/-0.0241 0.0466 pCi/g Europium-152 U
-0.018
+/-0.0549 0.0452 +/-0.0549 0.095 pCi/g Europium-154 U
-0.075
+/-0.072 0.0531
+/-0.072 0.117 pCi/g Europium-155 UI 0.00
+/-0.0819 0.0366 +/-0.0819 0.076 pCi/g Lead-212 0.948
+/-0.062 0.0241
+/-0.062 0.0503 pCi/g Lead-214 0.858
+/-0.0956 0.0298 +/-0.0956 0.0629 pCi/g Manganese-54 U3.090E-05
+/-0.0245 0.0203 +/-0.0245 0.0434 pCi/g Niobium-94 U
0.00428
+/-0.0201 0.0172 +/-0.0201 0.0367 pCi/g Potassium-40 15.7
+/-1.00 0.163
+/-1.00 0.366 pCi/g Radium-226 0.681
+/-0.0898 0.0352 +/-0.0898 0.0747 pCi/g Silver-108m U
-0.0104
+/-0.0174 0.0148 +/-0.0174 0.0314 pCi/g Thallium-208 0.322
+/-0.0446 0.018 +/-0.0446 0.0384 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 08/30/06 1546 563875 The following Analytical Methods were performed Method Description 1
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 60
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 15, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9304-0002-014F Proiect:
YANK01204 Sample ID:
170544014 Client ID:
YANK001 Vol. Recv.:
Parameter.
Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%
Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
61
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date:
September 15, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9304-0002-015F 170544015 Soil 21 -AUG-06 30-AUG-06 Client 4.74%
Project:
Client ID:
Vol. Recv.:
YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.02
+/-0.199 0.0755
+/-0.199 0.151 pCi/g MJHI 09/11/06 1137 563988 Americium-241 U
0.0553
+/-0.0835 0.0665 +/-0.0835 0.133 pCi/g Bismuth-212 0.531
+/-0.343 0.149
+/-0.343 0.298 pCi/g B3ismuth-214 0.718
+/-0.113 0.0359
+/-0.113 0.0717 pCi/g Cesium-134 U
0.0277
+/-0.034 0.0233
+/-0.034 0.0466 pCi/g Cesium-I 37 U
0.0311
+/-0.0234 0.0214 +/-0.0234 0.0427 pCi/g Cobalt-60 U
0.0157
+/-0.0273 0.024 +/-0.0273 0.048 pCi/g Europium-152 U
-0.0301
+/-0.0664 0.0505 +/-0.0664 0.101 pCi/g Europium-154 U
0.023
+/-0.0748 0.0643 +/-0.0748 0.128 pCi/g Europium-155 UI 0.00
+/-0.100 0.055
+/-0.100 0.110 pCi/g Lead-212 0.841
+/-0.0955 0.0303 +/-0.0955 0.0606 pCi/g Lead-214 0.720
+/-0.110 0.0355
+/-0.110 0.071 pCi/g Manganese-54 U
0.00593
+/-0.0257 0.0202 +/-0.0257 0.0405 pCi/g Niobium-94 U
0.00263
+/-0.0211 0.0185 +/-0.0211 0.0369 pCi/g Potassium-40 14.8
+/-1.36 0.173
+/-1.36 0.346 pCi/g Radium-226 0.718
+/-0.113 0.0359
+/-0.113 0.0717 pCi/g Silver-108m U
0.00263
+/-0.0211 0.0182 +/-0.0211 0.0363 pCi/g Thallium-208 0.239
+/-0.0521 0.0206 +/-0.0521 0.0412 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 08/30/06 1546 563875 The following Analytical Methods were performed Method Description I
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 62
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 15, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9304-0002-015F Project:
YANK01204 Sample ID:
170544015 Client ID:
YANKOO Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch l%
Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
63
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd
Contact:
Project:
East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date:
September 15, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9304-0002-016F 170544016 Soil 21-AUG-06 30-AUG-06 Client 3.9%
Project:
Client ID:
Vol. Recv.:
YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.951
+/-0.208 Americium-241 U
0.0192
+/-0.110 Bismuth-212 0.457
+/-0.343 Bismuth-214 0.962
+/-0.128 Cesium-134 U
0.0371
+/-0.0268 Cesium-137 0.0631
+/-0.0344 Cobalt-60 U
0.0177
+/-0.0244 Europium-152 U
0.017
+/-0.0714 Europium-154 U
-0.0354
+/-0.0687 Europium-155 U
0.0401
+/-0.0679 Lead-212 0.808
+/-0.0931 Lead-214 1.03
+/-0.137 Manganese-54 U
0.0157
+/-0.0231 Niobium-94 U
-0.0132
+/-0.0215 Potassium-40 12.4
+/-1.23 Radium-226 0.962
+/-0.128 Silver-108m U
0.0118
+/-0.0207 Thallium-208 0.196
+/-0.0541 0.0667 0.0823 0.148 0.0366 0.0246 0.0206 0.0221 0.0557 0.0548 0.0614 0.0309 0.0371 0.0211 0.0173 0.177 0.0366 0.0186 0.022
+/-0.208
+/-0.110
+/-0.343
+/-0.128
+/-0.0268
+/-0.0344
+/-0.0244
+/-0.0714
+/-0.0687
+/-0.0679
+/-0.0931
+/-0.137
+/-0.0231
+/-0.0215
+/-1.23
+/-0.128
+/-0.0207
+/-0.0541 0.133 0.165 0.295 0.0731 0.0493 0.0411 0.0442 0.111 0.110 0.123 0.0618 0.0742 0.0421 0.0345 0.353 0.0731 0.0371 0.044 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/11/06 1137 563988 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 08/30/06 1546 563875 The following Analytical Methods were performed Method Description I
EML HASL 300, 4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 64
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:
September 15, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9304-0002-016F Project:
YANK0 1204 Sample ID:
170544016 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A%
Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
65
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date:
September 15, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9304-0002-017F 170544017 Soil 21-AUG-06 30-AUG-06 Client 3.54%
Project:
Client ID:
Vol. Recv.:
YANKO 1204 YANK001 Parameter C
Rad Gamma Spec Analysis
?ualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A*
Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.872
+/-0.325 Americium-241 U
0.098
+/-0.0815 Bismuth-212 0.791
+1-0.500 Bismuth-214 7.52
+/-0.808 Cesium-134 U
0.030
+/-0.0491 Cesium-137 U
0.0292
+/-0.0494 Cobalt-60 U
-0.0101
+/-0.050 Europium-152 U
-0.0955
+/-0.173 Europium-154 U
0.0231
+/-0.166 Europium-155 U
0.0411
+/-0.150 Lead-212 0.855
+/-0.125 Lead-214 7.69
+/-0.715 Manganese-54 U
-0.0178
+/-0.0532 Niobium-94 U
0.0572
+/-0.0425 Potassium-40 11.9
+/-1.34 Radium-226 7.52
+/-0.808 Silver-108m U
-0.0424
+/-0.0392 Thallium-208 0.309
+/-0.0831 0.138 0.0655 0.303 0.0692 0.044 0.039 0.0409 0.0986 0.121 0,095 0.054 0.0681 0.0383 0.0391 0.390 0.0692 0.0321 0.0327
+/-0.325
+/-0.0815
+/-0.500
+/-0.808
+/-0.0491
+/-0.0494
+/-0.050
+/-0.173
+/-0.166
+/-0.150
+/-0.125
+/-0.715
+/-0.0532
+/-0.0425
+/-1.34
+/-0.808
+/-0.0392
+/-0.0831 0.276 0.131 0.606 0.138 0.0879 0.078 0.0817 0.197 0.241 0.190 0.108 0.136 0.0766 0.0782 0.779 0.138 0.0642 0.0654 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 09/11/06 1138 563988 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 08/30/06 1546 563875 The following Analytical Methods were performed Method Description I
EML HASL 300,4.5.2.3 Notes:
The Qualifiers in this report are defined as follows:
A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 66
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:
September 15, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9304-0002-017F Project:
YANK01 204 Sample ID:
170544017 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%
Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
67
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company :
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date:
September 15, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9304-0002-005F 170544018 Soil 21-AUG-06 30-AUG-06 Client 4.45%
Project:
Client ID:
Vol. Recv.:
YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%
Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 X
Curium-242 U
Curium-243/244 X
Alphaspec Pu, Solid-ALL FSS Plutonium-238 U
Plutonium-239/240 U
Liquid Scint Pu24 1, Solid-ALL FSS Plutonium-241 U
Rad Gamma Spec Analysis 0.416 0.034 0.375
+/-0.254
+/-0.0903
+/-0.253 0.00 0.0402 0.0629
+/-0.261
+/-0.0904
+/-0.259 0.109 0.202 0.235 0.149 0.222 14.5 0.0251
+/-0.0665 0.0296 +/-0.0665
-0.0396
+/-0.0347 0.0661
+/-0.035 11.0
+/-8.81 6.91
+/-8.87 Gamma, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.862
+/-0.189 Americium-241 U
0.0475
+/-0.0916 Bismuth-212 0.376
+/-0.342 Bismuth-214 0.665
+/-0.098 Cesium-134 UT 0.00
+/-0.0369 Cesium-137 U
0.00701
+/-0.0214 Cobalt-60 U
0.00123
+/-0.0207 Europium-152 U
0.0143
+/-0.0598 Europium-154 U
-0.021
+/-0.077 Europium-155 U
0.0156
+/-0.0608 Lead-212 0.868
+/-0.0965 Lead-214 0.659
+/-0.0993 Manganese-54 U
0.014
+/-0.0222 Niobium-94 U -0.00488
+/-0.0191 Potassium-40 15.4
+/-1.29 Radium-226 0.665
+/-0.098 Silver-108m U
-0.0112
+/-0.0188 Thallium-208 0.317
+/-0.0522 Rad Gas Flow Proportional Counting 0.0691 0.0761 0.149 0.0348 0.0244 0.0188 0.0176 0.0511 0.0564 0.0554 0.0285 0.0364 0.018 0.0159 0.167 0.0348 0.0159 0.0177
+/-0.189
+/-0.0916
+/-0.342
+/-0.098
+/-0.0369
+/-0.0214
+/-0.0207
+/-0.0598
+/-0.077
+/-0.0608
+/-0.0965
+/-0.0993
+/-0.0222
+/-0.0191
+/-1.29
+/-0.098
+/-0.0188
+/-0.0522 0.138 0.152 0.298 0.0695 0.0487 0.0375 0.0352 0.102 0.113 0.111 0.0569 0.0727 0.036 0.0318 0.334 0.0695 0.0318 0.0354 0.0328 11.4 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 09/14/06 0931 564247 BXL1 09/10/06 0859 564258 BXLI 09/13/06 0941 564259 MJHI 09/11/06 1524 563988 GFPC, Sr90, solid-ALL FSS Strontium-90 U
0.
Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U
0105
+/-0.0185 0.014 +/-0.0185 1.53
+/-6.54 5.42
+/-6.54 KSDI 09/09/06 1605 564153 DFA1 09/05/06 1744 564447 68
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date:
September 15, 2006 Client Sample ID:
Sample ID:
9304-0002-005F 170544018 Project:
Client ID:
Vol. Recv.:
YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%
Rad Liquid Scintillation Analysis Liquid Scint C14, Solid All, FSS Carbon-14 U
-0.095
+/-0.0729 0.0628 +/-0.0729 0.128 pCi/g AXD2 09/06/06 0701 564449 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U
-7.85
+/-34.0 23.2
+/-34.0 48.2 pCi/g MXPI 09/08/06 2325 564451 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U
3.94
+/-7.34 6.02
+/-7.35 12.5 pCi/g MXPI 09/09/06 0319 564452 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U
0.128
+/-0.272 0.225
+/-0.272 0.463 pCi/g KXR1 09/06/06 1605 564445 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 08/30/06 1546 563875 The following Analytical Methods were performed Method Description I
DOE EML HASL-300, Am-05-RC Modified 2
DOE EML HASL-300, Pu-I 1-RC Modified 3
DOE EML HASL-300, Pu-I -RC Modified 4
EML HASL 300,4.5.2.3 5
EPA 905.0 Modified 6
EPA 906.0 Modified 7
EPA EERF C-01 Modified 8
DOE RESL Fe-1, Modified 9
DOE RESL Ni-1, Modified 10 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%
Acceptable Limits Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL F5 GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS 68 86 90 81 75 66 81 (15%-125%)
(15%-125%)
(25%-125%)
(25%-125%)
(15%-125%)
(25%-125%)
(15%-125%)
69
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 15, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9304-0002-005F Project:
YANK01204 Sample ID:
170544018 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A Notes:
The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
70
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company :
Connecticut Yankee Atomic Power Address:
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date:
September 15, 2006 Client Sample ID:
Sample ID:
Matrix:
Collect Date:
Receive Date:
Collector:
Moisture:
9304-0002-008F 170544019 Soil 21-AUG-06 30-AUG-06 Client 4.7%
Proiect:
Client ID:
Vol. Recv.:
YANK01204 YANK00O Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch IN Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 X
Curium-242 U
Curium-243/244 U
Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -I Plutonium-239/240 U
Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U
Rad Gamma Spec Analysis 0.421 0.0454 0.134
+/-0.257
+/-0.089
+/-0.164 0.00 0.00 0.0637
+/-0.263
+/-0.0891
+/-0.165 0.111 0.123 0.239 0.174 0.224 12.9 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXL1 09/14/06 0931 564247 BXLI 09/10/06 0859 564258 BXLI 09/13/06 0958 564259 0.00926
+/-0.0182 0.0346 +/-0.0182 0.0879
+/-0.135 0.0599
+/-0.135
-2.25
+/-7.22 6.16
+/-7.22 Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.902 Americium-241 U
0.043 Bismuth-212 0.625 Bismuth-214 0.610 Cesium-134 U
0.0406 Cesium-] 37 U
0.00127 Cobalt-60 U -0.00106 Europium-152 U -0.00421 Europium-154 U
0.0662 Europium-155 U -0.00259 Lead-212 0.756 Lead-214 0.723 Manganese-54 U
0.0269 Niobium-94 U -0.00728 Potassium-40 12.9 Radium-226 0.610 Silver-108m U
0.00253 Thallium-208 0.248 Rad Gas Flow Proportional Counting
+/-0.268
+/-0.0406
+/-0.369
+/-0.137
+/-0.035
+/-0.0295
+/-0.0351
+/-0.0852
+/-0.110
+/-0.0574
+/-0.0918
+/-0.116
+/-0.0305
+/-0.0274
+/-1.23
+/-0.137
+/-0.0238
+/-0.0567 0.0945 0.0334 0.182 0.0427 0.0304 0.026 0.0291 0.0607 0.0972 0.0504 0.0307 0.0417 0.0282 0.0235 0.237 0.0427 0.0207 0.0244
+/-0.268
+/-0.0406
+/-0.369
+/-0.137
+/-0.035
+/-0.0295
+/-0.0351
+/-0.0852
+/-0.110
+/-0.0574
+/-0.0918
+/-0.116
+/-0.0305
+/-0.0274
+/-1.23
+/-0.137
+/-0.0238
+/-0.0567 0.189 0.0668 0.364 0.0853 0.0608 0.0519 0.0582 0.121 0.194 0.101 0.0615 0.0834 0.0564 0.0469 0.473 0.0853 0.0414 0.0488 0.0248 10.6 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/11/06 1524 563988 GFPC, Sr90, solid-ALL FSS Strontium-90 U
-0.(
Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U
0042
+/-0.0116 0.0105 +/-0.0116 1.43
+/-6.09 5.05
+/-6.09 KSDI 09/09/06 1605 564153 DFAI 09/05/06 1815 564447 71
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Report Date:
September 15, 2006 Client Sample ID:
Sample ID:
9304-0002-008F 170544019 Project:
YANKO 1204 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1' Rad Liquid Scintillation Analysis Liquid Scint C14, Solid AII, FSS Carbon-14 U
-0.0997
+/-0.0966 0.0841 +/-0.0966 0.174 pCi/g AXD2 09/06/06 0833 564449 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U
34.3
+/-41.0 27.1
+/-41.0 56.4 pCi/g MXPI 09/08/06 2342 564451 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U
9.11
+/-7.52 5.98
+/-7.52 12.5 pCi/g MXPI 09/09/06 0351 564452 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U
-0.0655
+/-0.262 0.221
+/-0.262 0.456 pCi/g KXRI 09/06/06 1621 564445 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 08/30/06 1546 563875 The following Analytical Methods were performed Method Description 1
DOE EML HASL-300, Am-05-RC Modified 2
DOE EML HASL-300, Pu-I I-RC Modified 3
DOE EML HASL-300, Pu-I 1-RC Modified 4
EML HASL 300, 4.5.2.3 5
EPA 905.0 Modified 6
EPA 906.0 Modified 7
EPA EERF C-01 Modified 8
DOE RESL Fe-1, Modified 9
DOE RESL Ni-1, Modified 10 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%
Acceptable Limits Americium-243 Plutonium-242 Carrier/Tracer Recovery Carier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS 67 74 100 103 68 71 81 (15%-125%)
(15%-125%)
(25%-125%)
(25%-125%)
(15%-125%)
(25%-125%)
(15%-125%)
72
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:
Connecticut Yankee Atomic Power Address :
362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date:
September 15, 2006
Contact:
Mr. Jack McCarthy Project:
Soils PO# 002332 Client Sample ID:
9304-0002-008F Project:
YANK0 1204 Sample ID:
170544019 Client ID:
YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Notes:
The Qualifiers in this report are defined as follows A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A
The TIC is a suspected aldol-condensation product B
Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C
Analyte has been confirmed by GC/MS analysis D
Results are reported from a diluted aliquot of the sample H
Analytical holding time was exceeded J
Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R
Sample results are rejected U
Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y
QC Samples were not spiked with this compound A
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h
Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
73
QUALITY CONTROL DATA 74
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Client :
Connecticut Yankee Atomic Power 362 Injun Hollow Rd Renort Date: September 15, 2006 Page 1 of 9 East Hampton, Connecticut
Contact:
Mr. Jack McCarthy Workorder:
170544 Parmname NOM Sample Qual QC Units RPD%
REC%
Range Anist Date Time Rad Alpha Spec Batch 564247 QC1201173420 Americium-241 Curium-242 Curium-243/244 QC1201173422 Americium-241 Curium-242 Curium-243/244 QC1201173419 Americium-241 Curium-242 Curium-243/244 QC1201173421 Americium-241 170543020 DUP x
0.667 Uncert:
+/-0.335 TPU:
+/-0.348 U
0.082 Uncert:
+/-0.131 TPU:
+/-0.132 U
0.255 Uncert:
+/-0.223 TPU:
+/-0.226 LCS MB 13.0 Uncert:
TPU:
Uncert:
TPU:
15.7 Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
X 0.300
+/-0.218
+/-0.221 U
0.0236
+/-0.0939
+/-0.0939 U
0.0428
+/-0.120
+/-0.121 11.7
+/-1.25
+/-1.92 U
0.0188
+/-0.075
+/-0.075 12.5
+/- 1.30
+/-2.02 U
-0.0458
+/-0.0756
+/-0.0757 U
0.00
+/-0.0739
+/-0.0739 U
-0.00877
+/-0.0737
+/-0.0738 pCi/g pCi/g pCi/g 143 76 111 (0%- 100%)
(0% - 100%)
pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 90 (75%-125%)
80 (75%-125%)
(0%- 100%) BXLI 09/14/06 09:31 170543020 MS Curium-242 13.5 Uncert:
TPU:
Uncert:
TPU:
16.3 Uncert:
TPU:
x 0.667
+/-0.335
+/-0.348 U
0.082
+/-0.131
+/-0.132 U
0.255
+/-0.223
+/-0.226 U
12.8
+/-1.35
+/-2.10 0.0211
+/-0.084
+/-0.0841 14.8
+/- 1.45
+/-2.36 90 (75%-125%)
Curium-243/244 91 (75%-125%)
Batch 564258 QC1201173424 170543020 DUP Plutonium-238 U
-0.0353 U
-0.00766 pCi/g 129 (0%- 100%) BXLI 09/10/0608:59 75
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:
170544 Page 2 of 9 REC%
Range Anist Parnmame Rad Alpha Spec Batch NOM Sample Qual QC Units RPD%
Date Time 564258 Plutonium-239/240 QC1201173426 LCS Plutonium-238 Plutonium-239/240 QC1201173423 MB Plutonium-238 Plutonium-239/240 QC1201173425 170543020 MS Plutonium-238 Uncert:
+/-0.0346 TPU:
+/-0.0349 U
-0.025 Uncert:
+/-0.0854 TPU:
+/-0.0855 Uncert:
TPU:
12.0 Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
U
-0.0353 Uncert:
+/-0.0346 TPU:
+/-0.0349 12.5 U
-0.025 Uncert:
+/-0.0854 TPU:
+/-0.0855 u
-4.55 Uncert:
+/-7.51 TPU:
+/-7.51
+/-0.015
+/-0.015 U
-0.0306
+/-0.030
+/-0.0302 U
0.00736
+/-0.0558
+/-0.0558 9.86
+/-1.00
+/-1.39 U
0.0173
+/-0.107
+/-0.107 U
-0.0751
+/-0.0773
+/-0.0776 U
-0.0128
+/-0.0662
+/-0.0662 11.5
+/-1.14
+/-1.62 U
4.44
+/-8.58
+/-8.59 pCi/g 20 (0%- 100%)
(75%- 125%)
pCi/g pCi/g pCi/g pCi/g pCi/g PGi/g 09/10/06 08:59 82 (75%-125%)
09/11/06 16:09 (75%-125%)
09/10/06 08:59 Plutonium-239/240 92 (75%-125%)
Batch 564259 QC1201173428 170543020 DUP Plutonium-241 QC1201173430 LCS Plutonium-241 QC1201173427 MB Plutonium-241 QC1201173429 170543020 MS Plutonium-241 Rad Gamma Spec Batch 563988 QC1201172835 170543021 DUP Actinium-228 pCi/g 0
(0% - 100%) BXLI 137 Uncert:
TPU:
Uncert:
TPU:
139 U
Uncert:
TPU:
140
+/-14.1
+/-19.7 U
1.82
+/-7.33
+/-7.33 pCi/g pCi/g pCi/g 103 (75%-125%)
09/13/06 10:30 09/13/06 11:03 09/13/06 10:14 09/13/06 10:47
-4.55
+/-7.51
+/-7.51 127
+/-12.9
+/-17.6 91 (75%-125%)
1.07
+/-0.229 Uncert:
0.953
+/-0.197
+/-0.197 pCi/g 11 (0% - 100%) MJH1 09/11/06 15:13 76
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:
170544 Parmname Rad Gamma Spec Batch 563988 Page 3 of 9 Ran2e AnIst Date Time NOM Sample Qual OC Units RPD%
REC %
Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 TPU:
+/-0.229 u
0.0273 Uncert:
+/-0.0421 TPU:
+/-0.0421 0.437 Uncert:
+/-0.373 TPU:
+/-0.373 0.570 Uncert:
+/-0.128 TPU:
+/-0.128 u
0.0383 Uncert:
+/-0.0339 TPU:
+/-0.0339 U
-0.011 Uncert:
+/-0.0293 TPU:
+/-0.0293 u
-0.00163 Uncert:
+/-0.0332 TPU:
+/-0.0332 u
0.044 Uncert:
+/-0.0764 TPU:
+/-0.0764 u
-0.00651 Uncert:
+1-0.105 TPU:
+/-0.105 U
0.0206 Uncert:
+/-0.0595 TPU:
+/-0.0595 0.772 Uncert:
+/-0.093 TPU:
+/-0.093 0.680 Uncert:
+/-0.109 TPU:
+/-0.109 U
0.0306 Uncert:
+/-0.0338 TPU:
+/-0.0338 U -1.500E-05 Uncert:
+/-0.0317 TPU:
+/-0.0317 15.3 Uncert:
+/-1.23 TPU:
+/-1.23 0.570 Uncert:
+/-0.128 TPU:
+/-0.128 U
-0.00955 Uncert:
+/-0.0232 U
-0.0503
+/-0.0891
+/-0.0891 0.783
+/-0.404
+/-0.404 0.699
+/-0.103
+/-0.103 U
0.0429
+/-0.0346
+/-0.0346 U
-0.00779
+/-0.0221
+/-0.0221 U
0.0113
+/-0.0398
+/-0.0398 U
-0.0504
+/-0.0579
+/-0.0579 U
0.0217
+/-0.0705
+/-0.0705 U
0.0875
+/-0.0954
+/-0.0954 0.903
+/-0.0706
+/-0.0706 0.793
+/-0.103
+/-0.103 U
0.00764
+/-0.0225
+/-0.0225 U
0.00524
+/-0.0208
+/-0.0208 15.2
+/-0.985
+/-0.985 0.699
+/-0.103
+/-0.103 U
-0.00886
+/-0.0196 pCi/g 677 pCi/g 57 pCi/g 20 pCi/g 12 pCi/g 34 pCi/g 268 pCi/g 2980 pCi/g 371 pCi/g 124 pCi/g 16 pCi/g 16 pCi/g 120 pCi/g 201 pCi/g 0
pCi/g 20 pCi/g 7
(0%- 100%)
(0%- 100%)
(0% - 100%)
(0%- 100%)
(0%- 100%)
(0%- 100%)
(0%- 100%)
(0%- 100%)
(0%- 100%)
(0%- 20%)
(0% - 20%)
(0%- 100%)
(0%- 100%)
(0%- 20%)
(0%- 100%)
(0%- 100%)
Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m 77
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:
170544 Parmname Rad Gamma Spec Batch 563988 Page 4 of 9 REC%
Range Anist Date Time NOM Sample Qual QC Units RPD%
Thallium-208 QC1201172836 Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 TPU:
+/-0.0232 0.296 Uncert:
+/-0.0555 TPU:
+/-0.0555
+/-0.0196 0.365
+/-0.0516
+/-0.0516 pCi/g 21 (0%- 100%)
LCS Uncert:
TPU:
23.4 Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
9.58 Uncert:
TPU:
14.5 Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
U 0.434
+/-0.559
+/-0.559 25.1
+/-1.99
+/-1.99 U
0.574
+/-0.992
+/-0.992 U
0.168
+/-0.258
+/-0.258 U
0.0765
+1-0.150
+/-0.150 10.0
+/-0.520
+/-0.520 15.4
+/-0.671
+/-0.671 U
0.317
+/-0.314
+/-0.314 U
-0.0025
+/-0.308
+/-0.308 U
0.102
+/-0.323
+/-0.323 U
0.0975
+/-0.163
+/-0.163 U
0.389
+/-0.367
+/-0.367 U
0.006
+/-0.141
+/-0.141 U
-0.0639
+/-0.126
+/-0.126 U
0.0608 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 09/11/06 15:13 107 (75%-125%)
105 (75%-125%)
106 (75%-125%)
Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 78
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:
170544 Page 5 of 9 REC%
Range AnIst Date Time Parmname NOM Sample Qual QC Units RPD%
Rad Gamma Spec Batch 563988 Radium-226 Silver-108m Thallium-208 QC 120117 2834 Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 MB Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
+1-1.18
+/-1.18 U
0.168
+/-0.258
+/-0.258 U
0.0118
+/-0.107
+/-0.107 U
0.0723
+/-0.123
+/-0.123 U
-0.0134
+/-0.0482
+/-0.0482 U
-0.00197
+/-0.0344
+/-0.0344 U
-0.0714
+/-0.104
+/-0.104 U
0.00749
+/-0.0298
+/-0.0298 U
-0.00829
+/-0.012
+/-0.012 U
0.00138
+/-0.012
+/-0.012 U
-0.00523
+/-0.0135
+/-0.0135 U
0.012
+/-0.0345
+/-0.0345 U
-0.000749
+/-0.0385
+/-0.0385 U
-0.00474
+/-0.0292
+/-0.0292 U
-0.022
+/-0.0278
+/-0.0278 U
-0.0013
+/-0.030
+/-0.030 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g (75%-125%)
09/11/06 15:25 Lead-212 Lead-214 79
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:
170544 Parnmiame Rad Gamma Spec Batch 563988 Manganese-54 Page 6 of 9 REC %
Range Anlst NOM Sample Qual QC Units RPD%
Date Time Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 Rad Gas Flow Batch Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
Uncert:
TPU:
U 0.00461
+/-0.0114
+/-0.0114 U
-0.000174
+/-0.0116
+/-0.0116 U
-0.104
+/-0.181
+/-0.181 U
0.00749
+/-0.0298
+/-0.0298 U
-0.00225
+/-0.0114
+/-0.0114 U
0.0218
+/-0.0268
+/-0.0268 pCi/g pCilg pCi/g pCi/g pCi/g pCi/g 564153 QC1201173180 170544018 DUP Strontium-90 QC1201173182 LCS Strontium-90 QC1201173179 MB Strontium-90 QC1201173181 170544018 MS Strontium-90 Rad Liquid Scintillation Batch 564445 QC1201173841 170544018 DUP Technetium-99 QC1201173843 LCS Technetium-99 QC1201173840 MB Technetium-99 U
0.0105 Uncert:
+/-0.0185 TPU:
+/-0.0185 U
0.00952
+/-0.0141
+/-0.0141 1.50
+/-0.0897
+/-0.0997 pCi/g 10 (0% - 100%) KSDI 1.56 Uncert:
TPU:
Uncert:
TPU:
3.10 U
Uncert:
TPU:
U
-0.0136
+/-0.0252
+/-0.0252 pCi/g pCi/g pCi/g 97 (75%-125%)
09/09/06 16:05 09/09/06 16:05 09/09/06 16:05 09/09/06 16:05 0.0105
+/-0.0185
+/-0.0185 2.33
+/-0.163
+/-0.177 75 (75%-125%)
U 0.128 Uncert:
+/-0.272 TPU:
+/-0.272 U
0.0496
+/-0.251
+/-0.251 13.0
+/-0.501
+/-0.582 pCi/g pCi/g 0
(0% - 100%) KXRI 12.7 Uncert:
TPU:
103 (75%-125%)
09/06/06 17:59 09/06/06 18:32 09/06/06 17:43 U
0.0991 pCi/g 80
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:
170544 Page 7 of 9 Parmname Rad Liquid Scintillation Batch 564445 NOM Sample Qual QC Units RPD%
REC%
Range Anist Date Time Uncert:
TPU:
QC1201173842 170544018 MS Technetium-99
+/-0.243
+/-0.243 13.3
+/-0.540
+/-0.620 13.1 U
Uncert:
TPU:
0.128
+/-0.272
+/-0.272 pCi/g 102 (75%-125%)
09/06/06 18:15 Batch 564447 QC1201173845 170544018 DUP Tritium QC1201173847 LCS Tritium QC1201173844 MB Tritium QC1201173846 170544018 MS Tritium U
1.53 Uncert:
+/-6.54 TPU:
+/-6.54 U
0.760
+/-5.24
+/-5.24 pCi/g 0
(0%- 100%) DFAI 46.9 Uncert:
TPU:
Uncert:
TPU:
54.5 U
Uncert:
TPU:
44.3
+/-8.94
+/-8.98 U
-0.43
+/-4.67
+/-4.67 pCi/g pCi/g pCi/g 95 (75%-125%)
09/05/06 21:25 09/07/06 11:21 09/05/06 20:54 09/07/06 11:05 1.53
+/-6.54
+/-6.54 57.4
+/-10.7
+/-10.7 105 (75%-125%)
Batch 564449 QC1201173849 170544019 DUP Carbon-14 QC1201173851 LCS Carbon-14 QC1201173848 MB Carbon-14 QC1201173850 170544019 MS Carbon-14 U
-0.0997 Uncert:
+/-0.0966 TPU:
+/-0.0966 6.66 Uncert:
TPU:
Uncert:
TPU:
U
-0.0804
+/-0.108
+/-0.108 6.26
+/-0.258
+/-0.276 U
-0.0326
+/-0.102
+/-0.102 6.85
+/-0.273
+/-0.293 U
25.2
+/-35.2
+/-35.3 pCi/g 0
pCi/g pCi/g pCi/g 94 (75%-125%)
(0% - 100%) 'XD2 09/09/06 05:04 09/06/06 13:38 09/06/06 12:02 09/06/06 13:07 6.86 U
Uncert:
TPU:
-0.0997
+/-0.0966
+/-0.0966 100 (75%-125%)
Batch 564451 QC1201173859 170543020 DUP Iron-55 U
77.6 Uncert:
+/-70.0 TPU:
+/-70.2 pCi/g 0
(0% - 100%) \\1XPI 09/09/06 00:15 09/09/06 00:49 QC1201173861 LCS Iron-55 628 Uncert:
TPU:
652
+/-52.8
+/-66.0 pCi/g 104 (75%-125%)
81
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:
170544 Page 8 of 9 Range Anlst Parmname Rad Liquid Scintillation Batch 564451 NOM Sample Qual QC Units RPD %
REC %
Date Time QC1201173858 MB Iron-55 QC1201173860 170543020 MS Iron-55 Uncert:
TPU:
707 U
Uncert:
TPU:
U 9.45
+/-38.6
+/-38.6 pCi/g pCi/g 09/08/06 23:59 09/09106 00:32 77.6
+/-70.0
+/-70.2 734
+/-58.4
+/-74.2 104 (75%-125%)
Batch 564452 QC1201173873 170543020 DUP Nickel-63 QC1201173875 LCS Nickel-63 QC1201173872 MB Nickel-63 QC1201173874 170543020 MS Nickel-63 U
1.42 Uncert:
+/-6.33 TPU:
+/-6.33 U
7.28
+/-7.57
+/-7.57 pCi/g 0
(0% - 100%) "IXPI 512 Uncert:
TPU:
Uncert:
TPU:
594 U
Uncert:
TPU:
468
+/-15.7
+/-21.7 U
10.4
+/-7.87
+/-7.87 pCi/g pCi/g pCi/g 92 (75%-125%)
09/09/06 04:54 09/09/06 05:58 09/09/06 04:23 09/09/06 05:26 1.42
+/-6.33
+/-6.33 542
+/-20.8
+/-27.9 91 (75%-125%)
Notes:
The Qualifiers in this report are defined as follows:
A B
BD C
D H
J N/A R
U UI X
Y A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported The TIC is a suspected aldol-condensation product Target analyte was detected in the associated blank Results are either below the MDC or tracer recovery is low Analyte has been confirmed by GC/MS analysis Results are reported from a diluted aliquot of the sample Analytical holding time was exceeded Value is estimated Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more Sample results are rejected Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL 82
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:
170544 Page 9 of 9 Parmname NOM Sample Qual QC Units RPD%
REC%
Range Anist Date Time A
h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike cone. by a factor of 4 or more.
- Indicates analyte is a surrogate compound.
A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.
For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.
Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.
83
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD ATTACHMENT 4 (DQA RESULTS)
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD ATTACHMENT 4A (PRELIMINARY DATA REVIEW)
Health Physics Procedure GPP-GGGR-R512 1 -001 Attachment B Health Physics Procedure GPP-GGGR-R5 121-001 Attachment B Preliminary Data Review Form - Samples for the Sign Test Survey Unit:
Survey Unit Name:
Classification:
Survey Media:
Type of Survey:
Type of Measurement:
Number of Measurements:
Operational DCGL:
9304- 0002 Southwest Protected Area Grounds Fn Status Sunrvey Gross Measurerent 15
- iiiii~ ~ ~ii~ii!
!i1ii!!iliii:iiii:
BASIC STATISTICAL QUANTITIES Cs-137 Co-60 Minimum Value:
8.36-03
-,6.90, 63 Maximum Value:
- 4.3Ez02' 2.53E-02 Mean:
9.96E-0 3 7.43E-03 Median:
8.31E-03 5.27E-03 Standard Deviation:
1.46E-02 1..08E-02 Skew:
0.905 0.467 RADIONUCLIDE CONCENTRATION (pCi/g)
Co-60 Cs Identified?
Co Identified?
NUMBER Cs-137 Performed By:
Date:
t 0 G, Date:
Independent Review:
Health Physics Procedure GPP-GGGR-R5123-000-Rev.CY-00(
Health Physics Procedure GPP-GGGR-R5 I 23-000-Rev~CY-00(
Preliminary Data Review Form - Judgemental Samples Survey Unit:
Survey Unit Name:
Classification:
Survey Media:
Type of Survey:
Type of Measurement:
Number of Measurements:
Operational DCGL:
9304- 0002 Southwest Protected Area Grounds I
Soil Final Status Survey Gross Measurement w
BASIC STATISTICAL QUANTITIES Cs-137 Co-60 Minimum Value:
2.92E 1.6OlE Maximum Value:
1E-02, "1.77E-02 Mean:
4.62E-02 3.80E-03 Median:
4.62E-02 3.80E-03)
Standard Deviation:
2.40E-02
.1.97E-02 Operational DCGL 4l75E+/-00 2.29E+00[
RADIONUCLIDE CONCENTRATION (pCi/g)
Cs ID'ed?
Co-60 Co ID'ed Date:
Performed By:
Independent Review:
h93/4a-~
Date:
1//
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD ATTACHMENT 4B (GRAPHICAL REPRESENTATION OF DATA)
Health Physics Procedure GGGR-R5123-Rev.CY-00 I Attachment C Quantile Plot For Cobalt - 60 Survey Unit:
9304-0002 Survey Unit Name: Southwest Protected Area Grounds Mean:
7.431--03 pCi/g 0.
0 U
C*
0-U 3OOE-02 2.50E-02 2,OOE-02 1.50E-02 1.00E-02 5.OOE-03 0.QOE+0O
-5.OOE-03
, :1' 40 0
.* 2.0
- 60 80
-1.00E-02 L Percentage Co46 Rank Percentage 6.86E-03 1
3 %
-2.82E-03 2
10%
-276E-03 3
17 %
-2.71 E-03 4
23 %
--tOSE-O 5
30%
-7.4E-05 6
37 %
123E03 7
43 %
527EO3 8
50 %
.81.E-0 9 57 %
120E-02 10 63%
130E-02 11 70%
1.57E-02 12 77%
2.22E-2 13 83%
14 90%
2.53E-02 15 97 %
Prepared By:
A oI.
eP"-1,,
A Reviewed By:
2.*Ea7 Date:
/0 0 (,
Date:
///2*/-)
z{
Health Physics Procedure GGGR-R5123-Rev.CY-00 I Attachment C Health Physics Procedure GGGR-R5123-Rev.CY-OOI Attachment C Survey Unit:
Survey Unit Name:
Mean:
Quantile Plot For Cesium - 137 9304-0002 Southwest Protected Area Grounds 9.96E-03 pCi/g C0 I-C0UC 0
5.OOE-02 4.OOE-02 3.OOE-02 2.OOE-02 1.OOE-02 0.OOE+00
-1.OOE-02
-2.OOE-02 80 100 A-T*.,
.20 40 60 Percentage Rank Percentage 1
3%
2 10%
3 17%
4 23%
5 30%
6 37 %
7 43%
8 50%
9 57%
10 63%
11 70%
12 77 %
13 83%
14 90%
15 97%
Prepared By: Y'ot Reviewed By:.
Date:
/
C -"
(.
Date:
j/ 0
-3/41
Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Survey Unit:
Survey Unit Name:
Mean:
Frequency Plot For Cesium-137 9304-0002 Southwest Protected Area Grounds 0.013 pCi/g 0
CD 0r 146' U.
5 4
3 2
1 0
-0.010 0.000 0.010 0.020 0.030 0.040 Upper End Value (pCilg)
Upper End Observation Observation %
Value Frequency Frequency
-0.010 2
13%
0.000 4
27%
0.010 4
27%
0.020 3
20%
0.030 1
7%
0.040 1
7%
Total 15 100%
Prepared By:
Date:
iu -. '
I Reviewed By:
Reviewed-By:***
&"ece.r Date:
Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Cobalt-60 Survey Unit:
9304-0002 Survey Unit Name: Southwest Protected Area Grounds Mean:
0.008 pCi/g Cr T
LL 7
6 5
4 3
2 1
0 4,***ý S&
-0.010 0.000 0.010 0.020 0.030 0.040 Upper End Value (pCilg)
Upper End Value
-0.010 0.000 0.010 0.020 0.030 0.040 Total Observation Observation %
Frequency Frequency 1
7%
6 40%
4 27%
3 20%
1 7%
0 0%
15 100%
2
, K
-~
/~&~'4.
~
T'~1
-)
Prepared By:
Reviewed By: t FS"4
_2f_
Date:
o - " - (- (
Date:
/le/lz
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD ATTACHMENT 4C (SIGN TEST)
Health Physics Procedure GPP-GGGR-R512 1 -000 Attachment A, Rev. CY-00 I MAJOR Sign Test Calculation Sheet For Multiple Radionuclisdes Survey Unit Number: 9304-0002 Survey Unit Name: Southwest Protected Area Grounds WP&IR#: 2006-038 Classification: I I TYPE I (a error):0.05 I TYPE I (3 error):0.05 Radionuclides:
Operational DCGL (pCi/g):
Cs-137 Co-60 4.75 2.29 Results Cs-137 Results Co-60 Weighted Sum (W,)
DCGL-Result Sign 1.59E-02
-8.36E-03
-3.16E-03 8.3 1E-03 7.0 1 E-03 9.55E-03 1.68E-02 1.27E-03
-8.14E-03
-2.1 8E-03 2;79E-03 1.07E-02 4.38E-02 2.40E-02 3.11 E-02 8.81E-03 7.19E-03 1.30E-02 3.92E-03
-7.74E-05
-6.99E-04 2.53E-02 1.28E-02 1.23E-03 2.01E-03 5.27E-03 4.31E-03
-6.86E-03 5.41 E-04
-1.06E-03
- 1.96E-04
-2.82E-03
-2.95E-03
-2.7 IE-03
-1,64E-03
-2.76E-03
-6.18E-04 2.42E-02 1.28E-02 2.22E-02 1.89E-02 1.20E-02 1.03 E-02 i.57E-02
-1.34E-02 Number of Positive Differences (S+):
9.93E-01 9.96E-0 I 1.00E+00 9.87E-01 9.98E-0I 9.96E-0 I 9.99E-0 I 1.00E+00 1.00E+00 1.OOE+00 1.00E+00 9.87E-01 9.8 1E-01 9.90E401 9.87E-0 I 15 Critical Value:
13 Survey Unit:
Meets Acceptance Criterion Performed By:-, ]
t
- /
)"
/
Independent Review
,, 5.
S4x7e--Zý Date:
Date:
//2 7
1
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD ATTACHMENT 4D (QC SPLIT RESULTS)
Connecticut Yankee Decommissioning Project Health Physics Procedure 24265-000-GPR-GGGR-R5124-000 Attachment A Split Sample Assessment Form Survey Area fSurvey
~
2 Survey SreAra 9304 Suvy 0002 Suvy Southwest Proteted Area Grounds
- Unit Unit Name:
Sample Plan or WPIR#:
2006-038 SML #:
9304-0002-OI0FS Sample
Description:
Comparison of split samples collected from sample measurement location #02 and analyzed using gamma spectroscopy by an off-site vendor laboratory. The standard sample was 9304-0002-001F the comparison sample was 9304-0002-001 FS.
STANDARD iCOMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable (Y/N)
Value Error Range Value Error Ratio Cs-137 1.59E-02
.33E-02 1
NONE 24I5-02 15s8E-02 1.54 N/A Co-60 8.81E-03 1.3E-02 I
NONE
.39E-02 9.80E-03 1.58 N/A K-40 1.09E+01 5.20E-01 21 0.75 1.33 1.14E+01 5.15E-01 1.05 Y
Comments/Corrective Actions: Cs-137 & Co-60 are reported at Table is provided to show acceptance criteria used levels significantly below detection limits, a small variance in to assess split samples.
the reported activity for the samples could result in a low resolution and a corresponding unsatisfactory comparison ratio.
Resolution Agreement Range Guidance for sample agreement was developed from USNRC 4
7 0.50 2.00 Inspection Procedure 84750 which does not provide agreement 8
15 0.60 1.66 ranges for resolutions less than 4. Therefore, a statement of 16 50 0.75 1.33 acceptability in such cases is not appropriate.However, K-40 51 200 0.80 1.25 was found to be present at an acceptable level of agreement.
Therefore, no further action is warranted.
> 200 0.85 1.18 Performed By:
Date:
Reviewed By:
D,,
Date WPIR - Work Plan and Inspection Record SML - Sample Measurement Location designation Page I of I
Connecticut Yankee Decommissioning Project Health Physics Procedure 24265-000-GPR-GGGR-R5124-000 Attachment A Split Sample Assessment Form Survey 9304 Survey 0002 Survey Unit Southwest Protected Area Grounds Area#:
Unit #:
IName:
Sample Plan or WPIR#:
2006-038 SML #:
93040002-O04FS Sample
Description:
Comparison of split samples collected from sample measurement location #10 and analyzed using gamma spectroscopy by an off-site vendor laboratory. The standard sample was 9304-0001-010F, the comparison sample was 9304-0001-01 OFS.
STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable (Y/N)
Value Error Range Value Error Ratio Cs-137 8.3 1E-03 9.80E-03 I
NONE-
-2.49E-03 1.0O1E-02
-0.30 N/A C100 2.5311-02 1.11 E-02 2
NONE-1,3313-03 9.4013-03 0.05 N/A K-40 1.I1OEI01I 4.27E-01 26 0.75 -
1.33 1.03E+01 4.07E-01 0.94 Y
Comments/Corrective Actions: Cs-137 & Co-60 are repoqrted at Table is provided to show acceptance criteria used
.levels significantly below detection limits, a 4mall variance in to assess split samples.
the reported activity for the samples could result in a low resolution and a corresiponding unsatisfactory comparison ratio.
Resolution Agreement Range Guidance for sample agreement was developed from USNRC.
7 0.50 2.00 Inspection Procedure 84750 which does not provide agregement 8
15 0.60 1.66 ranges for resolutions less than 4. Therefore, a statement of 16 50 0.75 1.33 ascceptability in such cases is not appropriate.However. K-40 51 200 0.80 1.25 was found to be present at an acceptable level of agreement.>200.518 Therefore, no further action is warranted.,
0
.511 Performed By:
Date:
Reviewed By:
Date:
?'C WPIR - Work Plan and Inspection Record SML - Sample Measurement Location designation Page I of I
SOUTHWEST PROTECTED AREA GROUNDS SURVEY UNIT 9304-0002 RELEASE RECORD ATTACHMENT 4E (COMPASS DQA WITH POWER CURVE)
DQA Surface Soil Report Assessment Summary Site:
Planner(s):
Survey Unit Name:
Report Number:
Survey Unit Samples:
Reference Area Samples:
Test Performed:
Judgmental Samples:
Assessment
Conclusion:
CY-03 RWM Southwest Protected Area Grounds 1
15 0
Sign Test Result:
0 EMC Result:
Reject Null Hypothesis (Survey Unit PASSES)
Not Performed Not Performed Retrospective Power Curve I
U I-.
-I C,
I.
3d C
1 0ý9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 01 0
chill_--___
~
I-0.0 0.2 0.4 0.6 0.8 1.0 Unity Rule Sum-of:Ratios, includldg background Prospectve Power U
1-beta Actual Power LBGR Estimated Power DCGL Retrospective Power 1.2 COMPASS vI.0.0 10111/2006 Page I