ML070120546

From kanterella
Jump to navigation Jump to search
Final Status Survey Final Report Phase III, Rev 1, Appendix A4 Survey Unit Release Record 9527-0003, East Mountain Side
ML070120546
Person / Time
Site: Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 09/18/2006
From:
Yankee Atomic Electric Co
To:
NRC/FSME
References
9527-0003, CY-06-128
Download: ML070120546 (138)


Text

Book 1 of 12 Final Status Survey Final Report Phase III Connecticut Yankee Atomic Power Company Haddam Neck Plant Haddam, Connecticut February 2006 Book 5 of 8 Final Status Survey Final Report Phase III Appendix A4 Survey Unit Release Record 9527-0003, East Mountain Side Revision 1, September 2006

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0003 RELEASE RECORD Revision 1 TABLE OF CONTENTS

1.

SURVEY UNIT DESCRIPTION........................................................... 3

2.

CLASSIFICATION BASIS.................................................................... 3

3.

DATA QUALITY OBJECTIVES (DQO).............................................. 5

4.

SURVEY DESIGN................................................................................. 8

5.

SURVEY IMPLEMENTATION.......................................................... 11

6.

SURVEY RESULTS............................................................................ 12

7.

QUALITY CONTROL......................................................................... 16

8.

INVESTIGATIONS AND RESULTS................................................. 17

9.

REMEDIATION AND RESULTS....................................................... 17

10. CHANGES FROM THE FINAL STATUS SURVEY PLAN............. 17
11. DATA QUALITY ASSESSMENT (DQA).......................................... 18
12. ANOMALIES....................................................................................... 18
13. CONCLUSION..................................................................................... 18
14. ATTACHMENTS................................................................................. 19 14.1 Attachment 1 - Figures (7 pages including cover) 14.2 Attachment 2 - Sample and Statistical Data (111 pages including covers)

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0003 RELEASE RECORD Revision 1 3

1.

SURVEY UNIT DESCRIPTION Survey Unit 9527-0003 (East Mountain Side) is designated as Final Status Survey (FSS) Class 2 and consists of 8,200 m2 (2.03 acres) of uninhabited open land located approximately 0.16 miles from the reference coordinate system benchmark used at Haddam Neck Plant (HNP) (see Attachment 1, Figure 1).

The survey unit is bounded by an unpaved road on the north (called north as oriented with the north to south flow of the Connecticut River) side, a fence to the east and south, and a partial fence to the west. The survey unit comprises wooded terrain with some steep rock ledge and rock outcroppings within the interior.

The soil of this survey unit meets the requirements for unrestricted release as a Class 2 survey unit under the criteria and requirements of the HNP License Termination Plan (LTP).

The reference coordinates associated with this survey unit are E014 through E022 by S067 through S076 (refer to License Termination Plan (LTP) Section 5.4.4). The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may not be part of this survey unit. The boundary of the survey unit was defined using a Global Positioning System (GPS).

2.

CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10, Survey Unit Classification. The historical information, scoping analyses and characterization results provided sufficient data to designate Survey Unit 9527-0003 as Class 2 in September 2005.

The Classification Basis Summary conducted for Survey Unit 9527-0003 consisted of:

a) A review of the 10CFR50.75 (g) (1) database, b) A review of the Initial Characterization Report and the Historic Site Assessment (HSA) Supplement, c) Historic and current survey records review, d) Visual inspections and a walkdown.

A review of the 10CFR50.75 (g) (1) database report identifies six (6) documents associated with or relating to this survey area.

a) Event PIR 80-37: Contamination was documented to be present in an area outside the restricted area. Small areas of low-level contamination were found on the facility grounds through routine survey in a normally non-radioactive area. The areas were cleaned up in 1980.

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0003 RELEASE RECORD Revision 1 4

b) Radiological Assessment Branch (RAB) memo NE-83-RA-1374 (September 1983): Results of a contamination survey outside the southeast RCA boundary has identified plant related activity in an adjacent survey area to 9527. According to the memo the source could have been the events described by PIR 80-37.

c) Adverse Condition Report ACR 97-0994: Soil sample analysis identified plant related radioactivity on hillside east of plant (in another survey unit of 9527).

d) Scoping Survey Report 1998: Results of scoping samples performed for decommissioning characterization data. Cesium-137 was the predominate radionuclide found in this survey unit during the scoping survey. No other plant-related radionuclides were identified in this survey unit.

e) Event CR 05-0244: Tank farm material with low-level fixed contamination was found on the East Mountain Side in another survey unit of 9527. The single piece of tent material was found in Survey Unit 9527-0005 along the fence and about five hundred fifty (550) feet from the nearest boundary of 9527-0003.

f) Memo ISC 05-045: Periodic surveillance following final status survey.

Surveillance is required periodically by the LTP to ensure the radiological condition does not significantly change from the FSS results. The memo documents no negative change in the radiological status.

A review of the Initial and Supplemental Characterization Reports as well as the previous Classification Basis Summaries provided no additional information pertinent to classification.

Characterization was performed by Site Closure personnel in April 2005 to determine existing conditions and obtain radiological data for Final Status Survey (FSS). The reported concentrations of Cs-137 found in the soil were statistically consistent with those concentrations in wooded areas determined from off-site locations as documented by Health Physics Technical Support Document (TSD) BCY-HP-0063, Background Cs-137 Concentration in Soil. The average concentration was 0.653 pCi/g which was slightly lower than expected; however, one (1) sample reported Cs-137 at a concentration of 1.18 pCi/g. The basic statistical quantities (i.e., mean, standard deviation, median) for Cs-137 and Co-60 are provided in Table 1.

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0003 RELEASE RECORD Revision 1 5

Table 1 - Basic Statistical Quantities for Cs-137 and Co-60 from the Characterization Survey Parameter Cs-137 (pCi/g)

Co-60 (pCi/g)

Minimum Value:

3.11E-01

-6.84E-03 Maximum Value:

1.18E+00 1.29E-01 Mean:

6.53E-01 2.17E-02 Median:

6.46E-01 1.28E-02 Standard Deviation:

2.52E-01 3.29E-02 The FSS Engineer performed a visual inspection and walkdown during September 2005 to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions.

The final designation was Class 2 based on historical information (HSA Supplement and LTP Table 2.10 and 2.11B) and characterization survey data which resulted in the expectation that no FSS sample would be reported in a concentration that that would exceed the LTP criteria.

3.

DATA QUALITY OBJECTIVES (DQO)

FSS design and planning used the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5.1-11, Preparation of Final Status Survey Plan, and the Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM). A summary of the main features of the DQO process are provided herein.

The DQO process incorporated hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is technically known as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection. In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would satisfy the release criteria objective of the FSS. Probabilistic sampling is a preferred method to select a sample so that each item in the population being studied has a known likelihood of being included in the sample. Probabilistic sampling might include simple random sampling where every sample has the same chance of being included, or systematic random sampling where samples are arranged in some order and a random starting point is selected.

The primary objective of the Final Status Survey Plan (FSSP) was to demonstrate that the level of residual radioactivity in Survey Unit 9527-0003 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0003 RELEASE RECORD Revision 1 6

A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity. This is done through the development of Derived Concentration Guideline Values (DCGLs). The DCGLs represent average levels of radioactivity above background levels and are presented in terms of surface or mass activity concentrations. Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL), existing groundwater radioactivity and additional future groundwater radioactivity from building basements and footings.

The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity. Equation 1 shows the mathematical relationship between the three (3) components and the total dose.

Equation 1:

HTotal=HSoil + HExisting GW + HFuture GW The total dose under the LTP criteria is 25 mrem/yr TEDE from all three components. The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for Connecticut Yankee (CY) is 19 mrem/yr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from soil must be reduced when using the existing and future groundwater dose values discussed above.

This survey unit is affected by existing groundwater (reference CY memo ISC 06-024 and the Final Status Survey Final Report Phase III). The dose contribution from existing groundwater is bounded at 2 mrem/yr TEDE based on field data.

This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no concrete foundations or footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater, the third dose component, is therefore 0 mrem/yr TEDE.

Equation 2:

19 mrem/yrTotal=17 mrem/yrSoil+2 mrem/yrExisting GW+0 mrem/yrFuture GW The allowable dose for soil in this survey unit is 17 mrem/yr TEDE as shown by Equation 2 above. The concentration of residual radioactivity resulting in 17 mrem/yr TEDE is designated as the Operational DCGL, and has been established for the radionuclides of concern as provided in Table 2. Note, the

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0003 RELEASE RECORD Revision 1 7

survey design used a much smaller value for investigation than the Operational DCGL provided by Table 2 to conservatively account for the contribution to the total dose from existing and future groundwater which had not been established at the time of planning the FSS.

Table 2 - Radionuclide Specific Base Case Soil DCGL, Operational DCGLs and Required Minimum Detectable Concentrations Radionuclide (1)

Base Case Soil DCGL (pCi/g) (2)

Operational DCGL (pCi/g) (3)

Required MDC (pCi/g) (4)

H-3 4.12E+02 2.80E+02 1.65E+01 C-14 5.66E+00 3.85E+00 2.26E-01 Mn-54 1.74E+01 1.18E+01 6.96E-01 Fe-55 2.74E+04 1.86E+04 1.10E+03 Co-60 3.81E+00 2.59E+00 1.52E-01 Ag-108m 7.14E+00 4.86E+00 2.86E-01 Ni-63 7.23E+02 4.92E+02 2.89E+01 Sr-90 1.55E+00 1.05E+00 6.20E-02 Nb-94 7.12E+00 4.84E+00 2.85E-01 Tc-99 1.26E+01 8.57E+00 5.04E-01 Cs-134 4.67E+00 3.18E+00 1.87E-01 Cs-137 7.91E+00 5.38E+00 3.16E-01 Eu-152 1.01E+01 6.87E+00 4.04E-01 Eu-154 9.29E+00 6.32E+00 3.72E-01 Eu-155 3.92E+02 2.67E+02 1.57E+01 Pu-238 2.96E+01 2.01E+01 1.18E+00 Pu-239/240 2.67E+01 1.82E+01 1.07E+00 Pu-241 8.70E+02 5.92E+02 3.48E+01 Am-241 (5) 2.58E+01 1.75E+01 1.03E+00 Cm-243/244 2.90E+01 1.97E+01 1.16E+00 (1) Bold indicates those radionuclides considered to be Hard to Detect (HTD)

(2) The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to 25 mrem/yr TEDE (3) The Operational DCGL is equivalent to 17 mrem/yr TEDE (4) The required MDC is equivalent to 1 mrem/yr TEDE (5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD). The preferred result is the alpha spectroscopys when both analyses are performed.

Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability. Characterization was performed in April 2005 as discussed in Section 2. Cesium-137 was found to be the predominate radionuclide of concern. Cobalt-60 was included in the

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0003 RELEASE RECORD Revision 1 8

survey design based on the 1997 scoping survey results. The basic statistical quantities (i.e., mean, standard deviation, median) for Cs-137 and Co-60 are provided in Table 1.

Instrument DQOs included a verification of the ability of the survey instrument to detect the radiation(s) of interest relative to the DCGL. Survey instrument response checks were to be performed before issue and after the instrument had been used. Control and accountability of survey instruments was to be maintained to assure the quality and prevent the loss of data.

Laboratory DQOs and analysis results were to be reported as actual calculated results. Results reported as less than Minimum Detectable Concentration

(<MDC) would not be accepted for FSS. Sample report summaries were to include unique sample identification, analytical method, radionuclide, result, and uncertainty of two standard deviations, laboratory data qualifiers, units, and the required and observed MDC.

4.

SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. To assist the FSS Engineers when preparing survey plans for FSS, guidance is provided in Procedure RPM 5.1-11, Preparation of Final Status Survey Plans. By design, the FSSP meets the ALARA criteria for soils as specified in Chapter 4 of the LTP. The FSSP uses an integrated sample design that combines scanning surveys and sampling which can be either random or biased.

Characterization was performed by Site Closure personnel in April 2005 to determine existing conditions and obtain radiological data for Final Status Survey (FSS). The DQO process determined that Cs-137 and Co-60 would be the radionuclides of concern (refer to Section 3). The sum of fractions or unity rule would be used with the individual Operational DCGLs because multiple radionuclides (Cs-137 and Co-60) were considered in the survey design. Other radionuclides identified during FSS would be evaluated to ensure adequate survey design and compliance with the unity rule.

Surrogate DCGLs were not required for this survey unit based on process knowledge from FSS of nearby adjacent areas and via screening under LTP Section 5.4.7.2, Gross Activity DCGLs. Radionuclide screening or de-selection is a process where an individual radionuclide or aggregate may be considered insignificant and eliminated from the FSS. The criteria for de-selection are concentrations less than 5% for individual radionuclides and less than 10% for aggregates.

The Elevated Measurement Comparison (EMC) did not apply to this survey unit since the survey unit is a Class 2 and discrete, elevated areas of contamination were not expected.

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0003 RELEASE RECORD Revision 1 9

The Sign Test was selected as the non-parametric statistical test. The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation. This approach was conservative since it included background Cs-137 as part of the sample set.

The number of soil samples for FSS was determined in accordance with Procedure RPM 5.1-12, Determination of the Number of Surface Samples for Final Status Survey. The Lower Bound of the Gray Region (LBGR) was set in accordance with Procedure RPM 5.1-11 to 0.79 to maintain the relative shift

(/) in the range of 1 and 3. A Prospective Power Curve was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of the MARSSIM in support of the decommissioning license termination rule (10 CFR 20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design. Survey design specified fifteen (15) surface soil samples for non-parametric statistical testing.

The grid pattern and locations of the soil samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, Identifying, and Marking Surface Sample Locations for Final Status Survey. Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A systematic triangular grid pattern with a random starting point was selected for sample design, which is appropriate for a Class 2 area.

Sample locations were identified using AutoCAD-Lt, a commercially available plotting software package with coordinates consistent with the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 3.

Table 3 -Sample Measurement Locations with Associated GPS Coordinates Designation Northing Easting 9527-0003-001F 237066.59 669086.55 9527-0003-002F 236929.20 669086.55 9527-0003-003F 236860.50 669046.89 9527-0003-004F 236860.50 669126.21 9527-0003-005F 236791.81 669007.23 9527-0003-006F 236791.81 669086.55 9527-0003-007F 236791.81 669165.88 9527-0003-008F 236723.11 669126.21 9527-0003-009F 236723.11 669205.54 9527-0003-010F 236723.11 669284.86 9527-0003-011F 236654.41 669165.88 9527-0003-012F 236654.41 669245.20 9527-0003-013F 236654.41 669324.52 9527-0003-014F 236585.72 669284.86 9527-0003-015F 236585.72 669364.19

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0003 RELEASE RECORD Revision 1 10 A minimum of two (2) judgmental or biased samples were to be collected at locations selected by FSS Supervision based on professional judgment and observation during characterization and walkdowns to determine areas having the potential for residual radioactivity (e.g., runoff and collection, area disturbance). The number of judgmental samples represented 13% percent of the number of samples that would be used for non-parametric statistical testing.

Although Procedure RPM 5.1-11 only specified that 5% of the samples be selected for HTD analysis, three (3) soil samples or 20% of the number of samples that would be used for non-parametric statistical testing were randomly selected for HTD radionuclide analysis using the Microsoft Excel RANDBETWEEN function. Each sample would be sent off-site for a full suite analysis of the HTD radionuclides specified in the LTP, Table 2-12, Radionuclides Potentially Present at Haddam Neck Plant.

The implementation of survey specific quality control measures as referenced by Procedure RPM 5.1-24, Split Sample Assessment for Final Status Survey, included the collection of two (2) soil samples for split sample analysis by the off-site laboratory. These locations were selected randomly using the Microsoft Excel RANDBETWEEN function. The number of quality control soil samples was determined to be 10% of fifteen (15) samples, rounded up to the next whole number.

The LTP specifies that scanning will be performed in a combination of systematic and judgmental measurements for a Class 2 land area and cover 10%

to 100% of the area. The fraction of scanning coverage was determined during the DQO process with the total amount and location(s) based on the likelihood of finding elevated activity during FSS. Approximately 25% of the survey unit was to be scanned based on the characterization survey and sampling results.

For this Class 2 survey unit, the Investigation Level for area scanning and soil sample measurement results are those levels specified in LTP, Table 5-8, Investigation Levels. Note, the survey design used a much smaller value for investigation than the Operational DCGL provided by Table 2 to conservatively account for the contribution to the total dose from existing and future groundwater which had not been established at the time of planning the FSS.

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0003 RELEASE RECORD Revision 1 11 Table 4 - Synopsis of the Survey Design (1)

Feature Design Criteria Basis Survey Unit Land Area 8,200 m2 Based on AutoCAD-Lt and Visual Sample Plan calculations Number of Measurements 15 Type 1 and Type 2 errors were 0.05, sigma was 0.103 pCi/g, the LBGR was adjusted to 0.79 to maintain Relative Shift in the range of 1 and 3, Relative Shift was 2 Grid Spacing 25.1 Based on triangular grid Interval Spacing 21.7 Based on triangular grid Design DCGL 2.53 pCi/g Cs-137 1.52 pCi/g Co-60 To achieve 8 mrem/yr TEDE Operational DCGL 5.38 pCi/g Cs-137 2.59 pCi/g Co-60 To achieve 17 mrem/yr TEDE (2) to demonstrate compliance with Equation 2 of this Release Record Scan Survey unit Coverage Approximately 25%

of the area The LTP requires >10% area coverage for Class 2 Survey Units Soil Investigation Level 2.53 pCi/g Cs-137 1.52 pCi/g Co-60 The Operational DCGL meets the LTP criteria for a Class 2 survey unit Scan Investigation Level Detectable over background The LTP specifies investigation at the MDCSCAN for a Class 2 survey unit when the MDCSCAN is greater than the Operational DCGL (1) The survey design used a much smaller value for investigation than the Operational DCGL provided by Table 2 as the total dose from existing and future groundwater had not been established at the time of planning the FSS (2) The allowable dose for soil in this survey unit is 17 mrem/yr TEDE as the bounding dose from existing and future groundwater has been established based on field data (reference CY memo ISC 06-024 and the Final Status Survey Final Report Phase III)

5.

SURVEY IMPLEMENTATION Final status survey field activities were conducted under Work Plan and Inspection Record (WP&IR) 2005-0054. The WP&IR package included a detailed FSSP, job safety analysis, job planning checklist and related procedures for reference. Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey. The Daily Survey Journal was used to document field activities and other information pertaining to the FSS.

Survey activities occurred September 1 through September 9, 2005.

The scan areas were marked out and scanned for elevated readings (see for Scan Area Results). Scanning was performed with an

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0003 RELEASE RECORD Revision 1 12 Eberline E-600 using a SPA-3 sodium iodide detector. The E-600 was operated in the rate-meter mode and used with audio response. The probe was positioned as close to the ground as possible and was moved at a scan speed of about 0.5 meters per second.

Using GPS coordinates, sample measurement locations were identified and marked with a surveyors flag for identification. At each sample measurement location, a one (1) meter radius around the sample flag was scanned for elevated radiation levels.

Fifteen (15) surface soil samples were collected and packaged in accordance with Haddam Neck Plant (HNP) Procedure RPM 5.1-3, Collection of Sample Media for Final Status Survey and FSS design. Samples were controlled, transported, stored, and transferred to the off-site laboratory using Chain-of-Custody (COC) protocol in accordance with Procedure RPM 5.1-5, Chain of Custody for Final Status Survey Samples.

Three (3) samples (9527-0003-003F, 9527-0003-007F and 9527-0003-010F) were randomly selected for HTD radionuclide analysis by the off-site laboratory.

Two (2) biased soil samples (9527-0003-016F and 9527-003-017F) were taken. These samples were analyzed using gamma spectroscopy by the off-site laboratory.

The implementation of survey specific quality control measures included the collection of two (2) samples (9527-0003-008F and 9527-0000-011F) for split sample analysis by the off-site laboratory.

6.

SURVEY RESULTS The seventeen (17) sample measurement locations identified in the FSS plan were scanned about a one (1) meter radius for elevated radiation levels. Table 5 provides an overview of the scan area survey. Scan area results are provided in.

Table 5-Scan Area Results for Sample Measurement Locations Sample Measurement Location Highest Logged Reading (kcpm)

Action Level (1)

(kcpm)

> Action Level (2) 1 13.3 14.4 No 2

16.3 17.6 No 3

20.2 20.3 No 4

21.0 25.5 No 5

28.5 38.7 No 6

41.5 44.7 No 7

19.8 22.0 No 8

38.4 44.4 No

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0003 RELEASE RECORD Revision 1 13 Table 5-Scan Area Results for Sample Measurement Locations Sample Measurement Location Highest Logged Reading (kcpm)

Action Level (1)

(kcpm)

> Action Level (2) 9 18.7 20.4 No 10 19.1 22.4 No 11 36.0 40.8 No 12 18.6 22.3 No 13 18.2 21.7 No 14 17.6 21.1 No 15 16.7 18.8 No 16 33.3 42.1 No 17 27.5 30.1 No (1) The action level is based on a measurement above ambient background (2) Samples are collected from the location within the boundaries of the scan yielding a response above the action level Twenty-two (22) areas were scanned for elevated radiation levels. Several elevated areas were identified. Table 6 provides an overview of the scan area survey. Scan area results are provided in Attachment 2.

Table 6-Scan Area Results Scan Area Highest Logged Reading (kcpm)

Action Level (1)

(kcpm)

Elevated Reading Identification (2)

Investigation Sample 1

16.2 18.0 None - no elevated areas identified None 2

17.3 18.0 None - no elevated areas identified None 3

19.0 20.0 None - no elevated areas identified None 4

20.5 23.0 None - no elevated areas identified None 5

20.5 23.7 None - no elevated areas identified None 6

19.8 29.5 None - no elevated areas identified None

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0003 RELEASE RECORD Revision 1 14 Table 6-Scan Area Results Scan Area Highest Logged Reading (kcpm)

Action Level (1)

(kcpm)

Elevated Reading Identification (2)

Investigation Sample 7

23.5 25.3 None - no elevated areas identified None 8

21.6 30.3 None - no elevated areas identified None 9

38.0 41.3 None - no elevated areas identified None 10 54.1 54.7 ER-02-15-1 9527-0003-018F 11 21.3 21.7 None - no elevated areas identified None 12 19.5 21.0 None - no elevated areas identified None 13 19.0 21.5 None - no elevated areas identified None 14 20.4 20.5 None - no elevated areas identified None 15 19.2 28.3 None - no elevated areas identified None 16 18.2 20.2 None - no elevated areas identified None 17 15.8 16.7 SC-03-10-0 None (3) 18 16.5 18.3 None - no elevated areas identified None 19 18.1 20.0 None - no elevated areas identified None 20 20.1 26.2 None - no elevated areas identified None

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0003 RELEASE RECORD Revision 1 15 Table 6-Scan Area Results Scan Area Highest Logged Reading (kcpm)

Action Level (1)

(kcpm)

Elevated Reading Identification (2)

Investigation Sample 21 21.1 31.6 None - no elevated areas identified None 22 35.5 42.5 None - no elevated areas identified None (1) The action level is based on a measurement above ambient background (2) ER and SC are abbreviations associated with the barcodes used in the field where ER stands for Elevated Reading and SC refers to Scan (3) Refer to Section 8 for additional detail The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories, LLC, Charleston, South Carolina. The laboratory analyzed the fifteen (15) samples taken for non-parametric statistical testing, the associated duplicates, and the biased samples using gamma spectroscopy. Gamma spectroscopy analysis was performed to the required MDC. Gamma spectroscopy results identified radionuclides other than Cs-137 and Co-60 meeting the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty). All could be de-selected or excluded using the 5% and 10% rule described in Section 4.

Cesium-137 was identified in all of the fifteen (15) samples. The average gamma spectroscopy results for Cs-137 were slightly higher than the concentrations of Cs-137 found in soil at off-site locations within the vicinity of the HNP as presented in the Health Physics TSD BCY-HP-0063.

None of the samples exceeded 37% of the Operational DCGL. Sample analysis did not require further investigation. A summary of the sample results is provided in Table 7.

Table 7-Summary of Soil Sample Results Sample Number Cs-137 pCi/g Co-60 pCi/g Fraction of the Operational DCGL (1) 9527-0003-001F 6.09E-01 1.55E-02 0.119 9527-0003-002F 5.75E-01 7.25E-03 0.110 9527-0003-003F 8.41E-01 3.86E-02 0.171 9527-0003-004F 1.83E+00 6.03E-02 0.363 9527-0003-005F 3.61E-01 2.23E-02 0.076 9527-0003-006F 5.09E-01 2.26E-03 0.095 9527-0003-007F 6.35E-01 1.53E-02 0.124 9527-0003-008F 1.62E+00 4.03E-02 0.317 9527-0003-009F 8.04E-01 0.00E+00 0.149

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0003 RELEASE RECORD Revision 1 16 Table 7-Summary of Soil Sample Results Sample Number Cs-137 pCi/g Co-60 pCi/g Fraction of the Operational DCGL (1) 9527-0003-010F 1.28E+00 2.73E-02 0.248 9527-0003-011F 1.21E+00 4.53E-02 0.242 9527-0003-012F 9.49E-01 3.90E-02 0.191 9527-0003-013F 1.69E+00 5.26E-02 0.334 9527-0003-014F 9.92E-01 2.94E-02 0.196 9527-0003-015F 5.50E-01 3.11E-02 0.114 (1) The Operational DCGLs from Table 2 are 5.38 pCi/g for Cs-137 and 2.59 pCi/g for Co-60 and are used in conjunction with the unity rule to achieve 17 mrem/yr TEDE The off-site laboratory also processed three (3) samples for HTD analysis as required by the sample plan. The requested analyses included alpha spectroscopy, gas proportional counting, and liquid scintillation depending on the radionuclide and the measurement method. All analyses met the required MDC. Table 8 lists the results for those radionuclides meeting the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty) in more than one sample. Table 8 lists the results for the HTD radionuclides that could not be de-selected based on either the 5% and 10%

rules.

Table 8-Hard-to-Detect Sample Results Sample Sr-90 (pCi/g)

C-14 (pCi/g)

Tc-99 (pCi/g)

Fraction of the Operational DCGL (1) 9527-0003-003F 3.82E-03 1.25E-01 3.96E-01 8.23E-02 9527-0003-007F 1.60E-02

-4.21E-02 2.01E-01 2.78E-02 9527-0003-010F 2.42E-02 1.09E-01 6.04E-01 1.22E-01 (1) The Operational DCGLs are 1.05 pCi/g for Sr-90, 3.85 pCi/g for C-14 and 8.57 pCi/g for Tc-99 used in conjunction with the unity rule Two (2) biased samples were collected at locations selected by FSS Supervision based on professional judgment and observation. Gamma spectroscopy analysis was performed by the off-site laboratory to the required MDC. None of the samples exceeded 24% of the Operational DCGL. No further action or investigations were required (see Table 9).

Table 9-Biased Sample Results Sample Number Cs-137 pCi/g Co-60 pCi/g Fraction of the Operational DCGL(1) 9527-0003-016F 1.12E+00 8.85E-02 0.242 9527-0003-017F 1.21E+00 2.31E-03 0.226 (1) The Operational DCGLs from Table 2 are 5.38 pCi/g for Cs-137 and 2.59 pCi/g for Co-60 and are used in conjunction with the unity rule to achieve 17 mrem/yr TEDE

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0003 RELEASE RECORD Revision 1 17

7.

QUALITY CONTROL The off-site laboratory processed the split samples and performed gamma spectroscopy analysis. Thirteen percent (13%) of the samples were selected for analysis, which exceeds the 5% minimum required by the LTP. The data were evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 as detailed in HNP Procedure RPM 5.1-24, Split Sample Assessment for Final Status Survey. There was acceptable agreement between field split results.

The sample analysis vendor, General Engineering Laboratories, LLC, Charleston, South Carolina, maintains quality control and quality assurance plans as part of normal operation. Refer to Attachment 2 for data and data quality analysis results.

8.

INVESTIGATIONS AND RESULTS One (1) localized area was found to verifiably exceed the investigation level during the scan area survey. A sample was collected from that location and was analyzed on-site using gamma spectroscopy. The analysis results for Cs-137 and C-60 are shown in Table 10.

Table 10- Confirmatory Sample Results Sample Number Cs-137 pCi/g Co-60 pCi/g Fraction of the Operational DCGL(1) 9527-0003-18F 9.91E-01 7.84E-02 0.214 (1) The Operational DCGLs from Table 2 are 5.38 pCi/g for Cs-137 and 2.59 pCi/g for Co-60 and are used in conjunction with the unity rule to achieve 17 mrem/yr TEDE Additional scanning was performed in one (1) small location in February 2006 to obtain additional data relevant to the DQOs. The scanning was performed over an area of about six hundred square feet (600 ft2). No elevated readings were identified.

9.

REMEDIATION AND RESULTS Historically, no remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to or as a result of the FSS. Health Physics TSD BCY-HP-0078, ALARA Evaluation of Soil Remediation in Support of Final Status Survey, determined that remediation beyond that required to meet the release criteria to be unnecessary and that the remaining residual radioactivity in soil was ALARA.

10.

CHANGES FROM THE FINAL STATUS SURVEY PLAN The survey was designed to 8 mrem/yr TEDE which was conservative and necessary at the time of FSS planning. It is no longer required as the total dose from existing and future groundwater has been established. The dose for soil used to demonstrate compliance with the LTP criteria is 17 mrem/yr TEDE as discussed in Section 2 of this Release Record.

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0003 RELEASE RECORD Revision 1 18 Three HTD radionuclides were reported in concentrations exceeding either the 5% and 10% rule for de-selection. Therefore, the individual Operational DCGLs for these radionuclides were included into sample design to demonstrate compliance with the unity rule and ensure adequate survey design in accordance with the DQOs. The result of the COMPASS computer run showed adequate power for the revised survey design. The revised survey design maintained the original fifteen (15) surface soil samples for non-parametric statistical testing.

11.

DATA QUALITY ASSESSMENT (DQA)

The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, Data Quality Assessment, for completeness and consistency.

The sampling design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs. The Sign Test shows that the survey unit passes FSS.

Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 2.

The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation).

The range of the data, about 2.9 standard deviations, was not unusually large.

The difference between the mean and median was 14% of the standard deviation. The difference is enough to indicate skewness in the data. The data was represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot shows slight positive skewness as confirmed by the calculated skew of 0.5 and some bimodality probably due to the differences in terrain and the collection of runoff.

All data, assessments, and graphical representations are provided in Attachment

2.
12.

ANOMALIES No anomalies were noted.

13.

CONCLUSION Survey Unit 9527-0003 has met the final DQOs of the FSS. The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved. Elevated Measurement Comparison and remediation was not required.

The sample data passed the Sign Test. The null hypothesis was rejected.

Graphical representation of data indicates significant positive skewness as that is probably due to the differences in terrain and the collection of runoff. The

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0003 RELEASE RECORD Revision 1 19 Retrospective Power Curve generated using COMPASS shows adequate power was achieved. The survey unit was properly designated as Class 2.

The dose contribution from soil is less than 3 mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.

This survey unit is affected by existing groundwater (reference CY memo ISC 06-024 and the Final Status Survey Final Report Phase III). The dose contribution from existing groundwater is bounded at 2 mrem/yr TEDE based on field data.

This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no concrete foundations or footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater, the third dose component, is therefore 0 mrem/yr TEDE.

14.

ATTACHMENTS 14.1 Attachment 1 - Figures 14.2 Attachment 2 - Sample and Statistical Data

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0003 RELEASE RECORD Figures (6 pages)

Feet 0

27 54

Feet 0

27 54

Feet 0

27 54

Feet 0

27 54

Feet 0

27 54

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0003 RELEASE RECORD Sample and Statistical Data

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0003 RELEASE RECORD a Sample Data (81 Pages)

TABLE OF CONTENTS General Narrative............................................................. 1 Chain of Custody..............................................................4 Cooler Receipt Checklist.................................................. 8 Radiological Analysis....................................................... 11 Sample Data Summary................................................25 Quality Control Data.....................................................68

Page 1 of 77

Page 2 of 77

Page 3 of 77

Page 4 of 77

Page 5 of 77

Page 6 of 77

Page 7 of 77

Page 8 of 77

Page 9 of 77

Page 10 of 77

RADIOLOGICAL ANALYSIS Page 11 of 77

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

SDG MSR#05-2244 Method/Analysis Information Product:

Alphaspec Am241, Cm, Solid ALL FSS Analytical Method:

DOE EML HASL-300, Am-05-RC Modified Prep Method:

Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:

Dry Soil Prep Analytical Batch Number:

467822 Prep Batch Number:

463017 Dry Soil Prep GL-RAD-A-021 Batch Number:

463013 Sample ID Client ID 145417017 9527-0003-003-F 145417018 9527-0003-007-F 145417019 9527-0003-010-F 1200948302 Method Blank (MB) 1200948303 145417017(9527-0003-003-F) Sample Duplicate (DUP) 1200948304 145417017(9527-0003-003-F) Matrix Spike (MS) 1200948305 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-011 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 145417017 (9527-0003-003-F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information Page 12 of 77

All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. An NCR was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Alphaspec Pu, Solid-ALL FSS Analytical Method:

DOE EML HASL-300, Pu-11-RC Modified Prep Method:

Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:

Dry Soil Prep Analytical Batch Number:

467823 Prep Batch Number:

463017 Dry Soil Prep GL-RAD-A-021 Batch Number:

463013 Sample ID Client ID 145417017 9527-0003-003-F 145417018 9527-0003-007-F 145417019 9527-0003-010-F 1200948313 Method Blank (MB) 1200948314 145417017(9527-0003-003-F) Sample Duplicate (DUP) 1200948315 145417017(9527-0003-003-F) Matrix Spike (MS) 1200948316 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-011 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Page 13 of 77

Designated QC The following sample was used for QC: 145417017 (9527-0003-003-F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Sample 1200948314 (9527-0003-003-F) was recounted due to high negative area.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. An NCR was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Pu241, Solid-ALL FSS Analytical Method:

DOE EML HASL-300, Pu-11-RC Modified Prep Method:

Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:

Dry Soil Prep Analytical Batch Number:

467827 Prep Batch Number:

463017 Dry Soil Prep GL-RAD-A-021 Batch Number:

463013 Sample ID Client ID 145417017 9527-0003-003-F 145417018 9527-0003-007-F 145417019 9527-0003-010-F 1200948317 Method Blank (MB) 1200948318 145417017(9527-0003-003-F) Sample Duplicate (DUP) 1200948319 145417017(9527-0003-003-F) Matrix Spike (MS) 1200948320 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 7.

Calibration Information:

Page 14 of 77

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 145417017 (9527-0003-003-F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. An NCR was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Gamma,Solid-FSS GAM & ALL FSS Analytical Method:

EML HASL 300, 4.5.2.3 Prep Method:

Dry Soil Prep Analytical Batch Number:

463112 Prep Batch Number:

463010 Sample ID Client ID 145417001 9527-0003-008-F 145417002 9527-0003-008-FS 145417003 9527-0003-011-F 145417004 9527-0003-011-FS Page 15 of 77

145417005 9527-0003-012-F 145417006 9527-0003-013-F 145417007 9527-0003-014-F 145417008 9527-0003-015-F 145417009 9527-0003-016-F 145417010 9527-0003-017-F 145417011 9527-0003-001-F 145417012 9527-0003-002-F 145417013 9527-0003-004-F 145417014 9527-0003-005-F 145417015 9527-0003-006-F 145417016 9527-0003-009-F 145417017 9527-0003-003-F 145417018 9527-0003-007-F 145417019 9527-0003-010-F 1200936934 Method Blank (MB) 1200936935 145417001(9527-0003-008-F) Sample Duplicate (DUP) 1200936936 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 10.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 145417001 (9527-0003-008-F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Page 16 of 77

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. An NCR was not generated for this SDG.

Additional Comments The relative percent difference for Bi-214 and Ra-226 failed precision requirements for duplicate 1200936935 (9527-0003-008-F). However, when the relative error ratio is calculated for both isotopes (1.85444 for each) precision is demonstrated.

Qualifier information Qualifier Reason Analyte Sample UI Data rejected due to interference.

Europium-155 145417015 Manganese-54 145417005 145417017 UI Data rejected due to low abundance.

Cesium-134 145417001 145417007 145417008 145417009 145417010 145417014 145417015 145417016 145417017 Cobalt-60 1200936935 145417016 Europium-155 145417008 Niobium-94 145417003 Silver-108m 145417014 UI Data rejected due to no valid peak.

Americium-241 145417002 Cobalt-60 145417002 Potassium-40 1200936934 Method/Analysis Information Product:

GFPC, Sr90, solid-ALL FSS Analytical Method:

EPA 905.0 Modified Prep Method:

Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:

Dry Soil Prep Analytical Batch Number:

467346 Prep Batch Number:

463017 Dry Soil Prep GL-RAD-A-021 Batch Number:

463013 Sample ID Client ID 145417017 9527-0003-003-F 145417018 9527-0003-007-F 145417019 9527-0003-010-F 1200947126 Method Blank (MB) 1200947127 145495001(9802-0000-001RA-SBIV) Sample Duplicate (DUP) 1200947128 145495001(9802-0000-001RA-SBIV) Matrix Spike (MS) 1200947129 Laboratory Control Sample (LCS)

Page 17 of 77

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 9.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 145495001 (9802-0000-001RA-SBIV).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples 1200947126 (MB) and 1200947127 (9802-0000-001RA-SBIV) were recounted due to a negative result greater than three times the error.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. An NCR was not generated for this SDG.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Tc99, Solid-ALL FSS Analytical Method:

DOE EML HASL-300, Tc-02-RC Modified Page 18 of 77

Analytical Batch Number:

464785 Sample ID Client ID 145417017 9527-0003-003-F 145417018 9527-0003-007-F 145417019 9527-0003-010-F 1200941136 Method Blank (MB) 1200941137 145417018(9527-0003-007-F) Sample Duplicate (DUP) 1200941138 145417018(9527-0003-007-F) Matrix Spike (MS) 1200941139 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 12.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 145417018 (9527-0003-007-F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. An NCR was not generated for this SDG.

Qualifier information Page 19 of 77

Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Fe55, Solid-ALL FSS Analytical Method:

DOE RESL Fe-1, Modified Prep Method:

Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:

Dry Soil Prep Analytical Batch Number:

464797 Prep Batch Number:

463017 Dry Soil Prep GL-RAD-A-021 Batch Number:

463013 Sample ID Client ID 145417017 9527-0003-003-F 145417018 9527-0003-007-F 145417019 9527-0003-010-F 1200941150 Method Blank (MB) 1200941151 145258021(9801-0000-Z2X 3-04) Sample Duplicate (DUP) 1200941152 145258021(9801-0000-Z2X 3-04) Matrix Spike (MS) 1200941153 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 145258021 (9801-0000-Z2X 3-04).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Page 20 of 77

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. An NCR was not generated for this SDG.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Ni63, Solid-ALL FSS Analytical Method:

DOE RESL Ni-1, Modified Prep Method:

Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:

Dry Soil Prep Analytical Batch Number:

464799 Prep Batch Number:

463017 Dry Soil Prep GL-RAD-A-021 Batch Number:

463013 Sample ID Client ID 145417017 9527-0003-003-F 145417018 9527-0003-007-F 145417019 9527-0003-010-F 1200941154 Method Blank (MB) 1200941155 145258021(9801-0000-Z2X 3-04) Sample Duplicate (DUP) 1200941156 145258021(9801-0000-Z2X 3-04) Matrix Spike (MS) 1200941157 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 7.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 145258021 (9801-0000-Z2X 3-04).

QC Information Page 21 of 77

All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. An NCR was not generated for this SDG.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

LSC, Tritium Dist, Solid-HTD2,ALL FSS Analytical Method:

EPA 906.0 Modified Analytical Batch Number:

467508 Sample ID Client ID 145417017 9527-0003-003-F 145417018 9527-0003-007-F 145417019 9527-0003-010-F 1200947551 Method Blank (MB) 1200947552 145495003(9802-0000-003RA-SBIV) Sample Duplicate (DUP) 1200947553 145495003(9802-0000-003RA-SBIV) Matrix Spike (MS) 1200947554 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 10.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information Page 22 of 77

The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 145495003 (9802-0000-003RA-SBIV).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples 1200947553 (9802-0000-003RA-SBIV) and 1200947554 (LCS) were recounted due to low/high recovery.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. An NCR was not generated for this SDG.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint C14, Solid All,FSS Analytical Method:

EPA EERF C-01 Modified Analytical Batch Number:

464786 Sample ID Client ID 145417017 9527-0003-003-F 145417018 9527-0003-007-F 145417019 9527-0003-010-F 1200941140 Method Blank (MB) 1200941141 145417017(9527-0003-003-F) Sample Duplicate (DUP) 1200941142 145417017(9527-0003-003-F) Matrix Spike (MS) 1200941143 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Page 23 of 77

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 145417017 (9527-0003-003-F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. An NCR was not generated for this SDG.

Qualifier information Manual qualifiers were not required.

Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.

The following data validator verified the information presented in this case narrative:

Reviewer:______________________________________________________________________________

Page 24 of 77

SAMPLE DATA

SUMMARY

Page 25 of 77

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report YANK001 Connecticut Yankee Atomic Power Co.

Client SDG: MSR#05-2244 GEL Work Order: 145417 Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

    • Indicates the analyte is a surrogate compound.

This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by The Qualifiers in this report are defined as follows:

    • Indicates the analyte is a surrogate compound.

< Result is less than amount reported.

> Result is greater than amount reported.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

P The response between the confirmation and the primary columns is >40% Different.

R Sample results are rejected.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Lab-specific qualifier-please see case narrative, data summary package or contact your project manager for details.

Y QC Samples were not spiked with this compound.

Z Paint Filter qualifier: Particulates passed through the filter. No free liquids were observed.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

for Page 26 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier AnalystDate Time Gamma,SolidFSS GAM & ALL FSS 463112 2340 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium228 Americium241 Bismuth212 Bismuth214 Cesium134 Cesium137 Cobalt60 Europium152 Europium154 Europium155 Lead212 Lead214 Manganese54 Niobium94 Potassium40 Radium226 Silver108m Thallium208 10/04/05 MJH1 U

UUI U

U U

U U

U U

0.0951 0.0435 0.240 0.057 0.0369 0.032 0.0355 0.0778 0.0855 0.0706 0.0416 0.0528 0.0342 0.0293 0.233 0.057 0.030 0.031 DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417001 TS 07SEP05 14SEP05 95270003008F YANK01204 Project:

YANK001 Client ID:

Client 0.969 0.0305 0.605 1.13 0.00 1.62 0.0403 0.0406 0.0161 0.0816 0.894 1.11 0.018 0.00549 9.17 1.13 0.00168 0.323

+/0.286

+/0.051

+/0.546

+/0.178

+/0.064

+/0.180

+/0.040

+/0.0963

+/0.122

+/0.0838

+/0.119

+/0.192

+/0.0408

+/0.0351

+/1.13

+/0.178

+/0.0371

+/0.083 362 Injun Hollow Road Notes:

The Qualifiers in this report are defined as follows :

Sample ID:

Receive Date:

Client Sample ID:

Matrix:

Collect Date:

Collector:

Moisture:

Batch

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

12.4%

0.202 0.089 0.504 0.119 0.0773 0.067 0.0756 0.161 0.184 0.145 0.0857 0.110 0.0717 0.0613 0.511 0.119 0.0622 0.0648 The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GLRADA021 09/15/05 463010 1501 TC1 Method Description Analyst Date Time Prep Batch M

The following Analytical Methods were performed Method Description

+/0.280

+/0.050

+/0.535

+/0.174

+/0.0627

+/0.176

+/0.0392

+/0.0944

+/0.120

+/0.0821

+/0.117

+/0.188

+/0.040

+/0.0344

+/1.11

+/0.174

+/0.0364

+/0.0813 TPU Uncertainty Vol. Recv.:

1 EML HASL 300, 4.5.2.3 1

LC MDA Page 27 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Parameter Result Units Qualifier AnalystDate Time DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417001 95270003008F YANK01204 Project:

YANK001 Client ID:

362 Injun Hollow Road Sample ID:

Client Sample ID:

Batch E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

M TPU Uncertainty Vol. Recv.:

LC MDA The above sample is reported on a dry weight basis.

Page 28 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier AnalystDate Time Gamma,SolidFSS GAM & ALL FSS 463112 2341 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium228 Americium241 Bismuth212 Bismuth214 Cesium134 Cesium137 Cobalt60 Europium152 Europium154 Europium155 Lead212 Lead214 Manganese54 Niobium94 Potassium40 Radium226 Silver108m Thallium208 10/04/05 MJH1 UUI U

UUI U

U U

U U

U 0.0722 0.0317 0.165 0.0439 0.0285 0.0242 0.0227 0.064 0.0748 0.0567 0.0347 0.0471 0.0247 0.021 0.189 0.0439 0.0228 0.0226 DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417002 TS 07SEP05 14SEP05 95270003008FS YANK01204 Project:

YANK001 Client ID:

Client 0.989 0.00 1.06 0.936 0.0318 1.37 0.00 0.0433 0.0337 0.0449 0.959 1.05 0.00751 0.00932 8.47 0.936 0.0146 0.353

+/0.230

+/0.0476

+/0.348

+/0.147

+/0.033

+/0.132

+/0.0781

+/0.0785

+/0.088

+/0.0672

+/0.128

+/0.166

+/0.0289

+/0.0267

+/1.09

+/0.147

+/0.0283

+/0.0792 362 Injun Hollow Road Notes:

The Qualifiers in this report are defined as follows :

Sample ID:

Receive Date:

Client Sample ID:

Matrix:

Collect Date:

Collector:

Moisture:

Batch

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

10.7%

0.156 0.0651 0.353 0.0926 0.0604 0.0511 0.0498 0.133 0.162 0.116 0.0717 0.0979 0.0525 0.0445 0.423 0.0926 0.0475 0.0479 The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GLRADA021 09/15/05 463010 1501 TC1 Method Description Analyst Date Time Prep Batch M

The following Analytical Methods were performed Method Description

+/0.225

+/0.0467

+/0.341

+/0.144

+/0.0324

+/0.130

+/0.0766

+/0.0769

+/0.0863

+/0.0658

+/0.125

+/0.162

+/0.0283

+/0.0261

+/1.07

+/0.144

+/0.0277

+/0.0776 TPU Uncertainty Vol. Recv.:

1 EML HASL 300, 4.5.2.3 1

LC MDA Page 29 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Parameter Result Units Qualifier AnalystDate Time DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417002 95270003008FS YANK01204 Project:

YANK001 Client ID:

362 Injun Hollow Road Sample ID:

Client Sample ID:

Batch E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

M TPU Uncertainty Vol. Recv.:

LC MDA The above sample is reported on a dry weight basis.

Page 30 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier AnalystDate Time Gamma,SolidFSS GAM & ALL FSS 463112 2341 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium228 Americium241 Bismuth212 Bismuth214 Cesium134 Cesium137 Cobalt60 Europium152 Europium154 Europium155 Lead212 Lead214 Manganese54 Niobium94 Potassium40 Radium226 Silver108m Thallium208 10/04/05 MJH1 U

U U

U U

U UUI U

0.0506 0.0875 0.113 0.0271 0.0181 0.0167 0.015 0.0423 0.0446 0.0491 0.0275 0.0292 0.0135 0.0132 0.114 0.0271 0.0136 0.0142 DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417003 TS 07SEP05 14SEP05 95270003011F YANK01204 Project:

YANK001 Client ID:

Client 0.712 0.0335 0.553 0.961 0.0267 1.21 0.0453 0.0158 0.0344 0.0798 0.882 1.08 0.0148 0.00 14.9 0.961 6.080E 05 0.276

+/0.141

+/0.105

+/0.241

+/0.0854

+/0.0348

+/0.0631

+/0.0377

+/0.0497

+/0.0582

+/0.0672

+/0.0611

+/0.0915

+/0.0184

+/0.0227

+/0.786

+/0.0854

+/0.0161

+/0.0354 362 Injun Hollow Road Notes:

The Qualifiers in this report are defined as follows :

Sample ID:

Receive Date:

Client Sample ID:

Matrix:

Collect Date:

Collector:

Moisture:

Batch

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

9.88%

0.107 0.180 0.238 0.0569 0.0379 0.0348 0.0322 0.0877 0.0953 0.101 0.0566 0.0607 0.0285 0.0277 0.250 0.0569 0.0284 0.0299 The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GLRADA021 09/15/05 463010 1501 TC1 Method Description Analyst Date Time Prep Batch M

The following Analytical Methods were performed Method Description

+/0.138

+/0.103

+/0.236

+/0.0837

+/0.0341

+/0.0619

+/0.0369

+/0.0487

+/0.0571

+/0.0658

+/0.0599

+/0.0896

+/0.018

+/0.0222

+/0.770

+/0.0837

+/0.0158

+/0.0347 TPU Uncertainty Vol. Recv.:

1 EML HASL 300, 4.5.2.3 1

LC MDA Page 31 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Parameter Result Units Qualifier AnalystDate Time DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417003 95270003011F YANK01204 Project:

YANK001 Client ID:

362 Injun Hollow Road Sample ID:

Client Sample ID:

Batch BD Results below the MDC or low tracer recovery.

E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

M TPU Uncertainty Vol. Recv.:

LC MDA The above sample is reported on a dry weight basis.

Page 32 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier AnalystDate Time Gamma,SolidFSS GAM & ALL FSS 463112 1126 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium228 Americium241 Bismuth212 Bismuth214 Cesium134 Cesium137 Cobalt60 Europium152 Europium154 Europium155 Lead212 Lead214 Manganese54 Niobium94 Potassium40 Radium226 Silver108m Thallium208 10/10/05 MJH1 U

U U

U U

U U

U U

0.0568 0.0209 0.134 0.0308 0.0251 0.0175 0.0242 0.0441 0.0579 0.0339 0.0215 0.032 0.0176 0.0168 0.139 0.0308 0.0166 0.0165 DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417004 TS 07SEP05 14SEP05 95270003011FS YANK01204 Project:

YANK001 Client ID:

Client 0.658 0.00577 0.408 0.833 0.0478 1.05 0.0425 0.025 0.0209 0.0679 0.782 0.949 0.032 0.0126 11.6 0.833 0.000114 0.259

+/0.183

+/0.0245

+/0.264

+/0.139

+/0.0319

+/0.110

+/0.0258

+/0.0554

+/0.0732

+/0.0626

+/0.100

+/0.127

+/0.0276

+/0.0196

+/1.10

+/0.139

+/0.0193

+/0.0613 362 Injun Hollow Road Notes:

The Qualifiers in this report are defined as follows :

Sample ID:

Receive Date:

Client Sample ID:

Matrix:

Collect Date:

Collector:

Moisture:

Batch

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

10.9%

0.122 0.043 0.285 0.0653 0.0528 0.0371 0.0518 0.092 0.125 0.0701 0.0448 0.0668 0.0376 0.0356 0.313 0.0653 0.0347 0.0351 The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GLRADA021 09/15/05 463010 1501 TC1 Method Description Analyst Date Time Prep Batch M

The following Analytical Methods were performed Method Description

+/0.179

+/0.024

+/0.258

+/0.136

+/0.0312

+/0.108

+/0.0253

+/0.0543

+/0.0718

+/0.0613

+/0.098

+/0.125

+/0.027

+/0.0192

+/1.08

+/0.136

+/0.0189

+/0.060 TPU Uncertainty Vol. Recv.:

1 EML HASL 300, 4.5.2.3 1

LC MDA Page 33 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Parameter Result Units Qualifier AnalystDate Time DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417004 95270003011FS YANK01204 Project:

YANK001 Client ID:

362 Injun Hollow Road Sample ID:

Client Sample ID:

Batch E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

M TPU Uncertainty Vol. Recv.:

LC MDA The above sample is reported on a dry weight basis.

Page 34 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier AnalystDate Time Gamma,SolidFSS GAM & ALL FSS 463112 1127 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium228 Americium241 Bismuth212 Bismuth214 Cesium134 Cesium137 Cobalt60 Europium152 Europium154 Europium155 Lead212 Lead214 Manganese54 Niobium94 Potassium40 Radium226 Silver108m Thallium208 10/10/05 MJH1 U

U U

U U

U UUI U

U 0.0806 0.0308 0.160 0.0403 0.0277 0.025 0.0317 0.054 0.0775 0.049 0.0302 0.0385 0.0211 0.021 0.193 0.0403 0.0195 0.0243 DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417005 TS 07SEP05 14SEP05 95270003012F YANK01204 Project:

YANK001 Client ID:

Client 0.726 0.0206 0.634 0.838 0.0404 0.949 0.039 0.0194 0.0401 0.0508 0.703 0.854 0.00 0.0065 8.19 0.838 0.0211 0.274

+/0.200

+/0.0365

+/0.391

+/0.136

+/0.0433

+/0.108

+/0.034

+/0.0715

+/0.0925

+/0.0589

+/0.0905

+/0.140

+/0.0448

+/0.0256

+/1.12

+/0.136

+/0.0229

+/0.0645 362 Injun Hollow Road Notes:

The Qualifiers in this report are defined as follows :

Sample ID:

Receive Date:

Client Sample ID:

Matrix:

Collect Date:

Collector:

Moisture:

Batch

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

9.95%

0.175 0.0635 0.346 0.0861 0.0594 0.0531 0.0685 0.114 0.169 0.102 0.0629 0.0811 0.0458 0.0449 0.438 0.0861 0.0411 0.0516 The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GLRADA021 09/15/05 463010 1501 TC1 Method Description Analyst Date Time Prep Batch M

The following Analytical Methods were performed Method Description

+/0.196

+/0.0358

+/0.383

+/0.133

+/0.0425

+/0.105

+/0.0334

+/0.0701

+/0.0907

+/0.0577

+/0.0887

+/0.137

+/0.0439

+/0.0251

+/1.10

+/0.133

+/0.0224

+/0.0632 TPU Uncertainty Vol. Recv.:

1 EML HASL 300, 4.5.2.3 1

LC MDA Page 35 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Parameter Result Units Qualifier AnalystDate Time DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417005 95270003012F YANK01204 Project:

YANK001 Client ID:

362 Injun Hollow Road Sample ID:

Client Sample ID:

Batch E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

M TPU Uncertainty Vol. Recv.:

LC MDA The above sample is reported on a dry weight basis.

Page 36 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier AnalystDate Time Gamma,SolidFSS GAM & ALL FSS 463112 1159 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium228 Americium241 Bismuth212 Bismuth214 Cesium134 Cesium137 Cobalt60 Europium152 Europium154 Europium155 Lead212 Lead214 Manganese54 Niobium94 Potassium40 Radium226 Silver108m Thallium208 10/10/05 MJH1 U

U U

U U

U U

U 0.0709 0.0322 0.149 0.0365 0.0244 0.0208 0.0207 0.0579 0.0647 0.0516 0.034 0.0424 0.0206 0.0184 0.188 0.0365 0.0206 0.0208 DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417006 TS 07SEP05 14SEP05 95270003013F YANK01204 Project:

YANK001 Client ID:

Client 0.750 0.0235 0.740 0.748 0.0254 1.69 0.0526 0.0203 0.0197 0.0256 0.783 0.919 0.00172 0.0149 10.8 0.748 0.00858 0.282

+/0.195

+/0.0415

+/0.358

+/0.122

+/0.0281

+/0.149

+/0.0498

+/0.0689

+/0.0804

+/0.060

+/0.109

+/0.157

+/0.0283

+/0.0236

+/1.13

+/0.122

+/0.024

+/0.0571 362 Injun Hollow Road Notes:

The Qualifiers in this report are defined as follows :

Sample ID:

Receive Date:

Client Sample ID:

Matrix:

Collect Date:

Collector:

Moisture:

Batch

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

10.3%

0.152 0.0658 0.318 0.0772 0.0518 0.0441 0.0451 0.120 0.140 0.106 0.0701 0.0881 0.0439 0.039 0.415 0.0772 0.0429 0.0438 The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GLRADA021 09/15/05 463010 1501 TC1 Method Description Analyst Date Time Prep Batch M

The following Analytical Methods were performed Method Description

+/0.191

+/0.0406

+/0.351

+/0.120

+/0.0275

+/0.146

+/0.0488

+/0.0675

+/0.0788

+/0.0588

+/0.107

+/0.154

+/0.0277

+/0.0231

+/1.11

+/0.120

+/0.0235

+/0.056 TPU Uncertainty Vol. Recv.:

1 EML HASL 300, 4.5.2.3 1

LC MDA Page 37 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Parameter Result Units Qualifier AnalystDate Time DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417006 95270003013F YANK01204 Project:

YANK001 Client ID:

362 Injun Hollow Road Sample ID:

Client Sample ID:

Batch E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

M TPU Uncertainty Vol. Recv.:

LC MDA The above sample is reported on a dry weight basis.

Page 38 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier AnalystDate Time Gamma,SolidFSS GAM & ALL FSS 463112 1201 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium228 Americium241 Bismuth212 Bismuth214 Cesium134 Cesium137 Cobalt60 Europium152 Europium154 Europium155 Lead212 Lead214 Manganese54 Niobium94 Potassium40 Radium226 Silver108m Thallium208 10/10/05 MJH1 U

UUI U

U U

U U

U U

0.055 0.0961 0.111 0.0287 0.0208 0.0158 0.0206 0.0419 0.0441 0.0541 0.0274 0.0316 0.0172 0.0144 0.153 0.0287 0.0152 0.016 DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417007 TS 07SEP05 14SEP05 95270003014F YANK01204 Project:

YANK001 Client ID:

Client 0.990 0.0764 0.654 1.05 0.00 0.992 0.0294 0.0465 0.014 0.0463 0.986 1.22 0.00829 0.0133 11.8 1.05 0.00581 0.294

+/0.152

+/0.115

+/0.314

+/0.107

+/0.0292

+/0.0632

+/0.0293

+/0.0508

+/0.056

+/0.0604

+/0.0658

+/0.0953

+/0.021

+/0.017

+/0.760

+/0.107

+/0.0178

+/0.0431 362 Injun Hollow Road Notes:

The Qualifiers in this report are defined as follows :

Sample ID:

Receive Date:

Client Sample ID:

Matrix:

Collect Date:

Collector:

Moisture:

Batch

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

12%

0.116 0.198 0.234 0.060 0.0435 0.0331 0.0435 0.0871 0.0945 0.111 0.0564 0.0655 0.0362 0.0303 0.330 0.060 0.0316 0.0334 The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GLRADA021 09/15/05 463010 1501 TC1 Method Description Analyst Date Time Prep Batch M

The following Analytical Methods were performed Method Description

+/0.149

+/0.113

+/0.308

+/0.105

+/0.0286

+/0.062

+/0.0287

+/0.0498

+/0.0549

+/0.0592

+/0.0645

+/0.0934

+/0.0206

+/0.0167

+/0.745

+/0.105

+/0.0174

+/0.0422 TPU Uncertainty Vol. Recv.:

1 EML HASL 300, 4.5.2.3 1

LC MDA Page 39 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Parameter Result Units Qualifier AnalystDate Time DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417007 95270003014F YANK01204 Project:

YANK001 Client ID:

362 Injun Hollow Road Sample ID:

Client Sample ID:

Batch E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

M TPU Uncertainty Vol. Recv.:

LC MDA The above sample is reported on a dry weight basis.

Page 40 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier AnalystDate Time Gamma,SolidFSS GAM & ALL FSS 463112 1202 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium228 Americium241 Bismuth212 Bismuth214 Cesium134 Cesium137 Cobalt60 Europium152 Europium154 Europium155 Lead212 Lead214 Manganese54 Niobium94 Potassium40 Radium226 Silver108m Thallium208 10/10/05 MJH1 U

UUI U

U U

UUI U

U U

0.0444 0.0518 0.109 0.0279 0.0192 0.0131 0.0155 0.0381 0.0433 0.048 0.0229 0.0265 0.0157 0.0129 0.124 0.0279 0.013 0.0146 DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417008 TS 07SEP05 14SEP05 95270003015F YANK01204 Project:

YANK001 Client ID:

Client 0.959 0.00712 0.583 1.04 0.00 0.550 0.0311 0.0257 0.0316 0.00 1.02 1.07 0.000186 0.00168 11.7 1.04 0.000447 0.286

+/0.173

+/0.0584

+/0.297

+/0.142

+/0.0342

+/0.0676

+/0.0179

+/0.0466

+/0.0585

+/0.0814

+/0.104

+/0.130

+/0.0193

+/0.0157

+/0.975

+/0.142

+/0.0158

+/0.0485 362 Injun Hollow Road Notes:

The Qualifiers in this report are defined as follows :

Sample ID:

Receive Date:

Client Sample ID:

Matrix:

Collect Date:

Collector:

Moisture:

Batch

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

11.4%

0.0939 0.106 0.228 0.0581 0.0399 0.0274 0.0328 0.0788 0.0918 0.0981 0.047 0.0549 0.0328 0.0269 0.268 0.0581 0.027 0.0305 The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GLRADA021 09/15/05 463010 1501 TC1 Method Description Analyst Date Time Prep Batch M

The following Analytical Methods were performed Method Description

+/0.170

+/0.0573

+/0.291

+/0.139

+/0.0336

+/0.0662

+/0.0176

+/0.0456

+/0.0573

+/0.0798

+/0.102

+/0.128

+/0.0189

+/0.0154

+/0.955

+/0.139

+/0.0155

+/0.0476 TPU Uncertainty Vol. Recv.:

1 EML HASL 300, 4.5.2.3 1

LC MDA Page 41 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Parameter Result Units Qualifier AnalystDate Time DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417008 95270003015F YANK01204 Project:

YANK001 Client ID:

362 Injun Hollow Road Sample ID:

Client Sample ID:

Batch E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

M TPU Uncertainty Vol. Recv.:

LC MDA The above sample is reported on a dry weight basis.

Page 42 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier AnalystDate Time Gamma,SolidFSS GAM & ALL FSS 463112 1713 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium228 Americium241 Bismuth212 Bismuth214 Cesium134 Cesium137 Cobalt60 Europium152 Europium154 Europium155 Lead212 Lead214 Manganese54 Niobium94 Potassium40 Radium226 Silver108m Thallium208 10/10/05 MJH1 U

UUI U

U U

U U

U 0.071 0.0882 0.157 0.0395 0.0276 0.0208 0.0203 0.0553 0.0636 0.0621 0.0311 0.0418 0.0199 0.0192 0.153 0.0395 0.0209 0.0206 DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417009 TS 07SEP05 14SEP05 95270003016F YANK01204 Project:

YANK001 Client ID:

Client 0.833 0.0183 0.479 0.752 0.00 1.12 0.0885 0.00156 0.0179 0.0755 0.922 0.816 0.0077 0.0045 10.6 0.752 0.0187 0.257

+/0.210

+/0.103

+/0.325

+/0.113

+/0.0389

+/0.0873

+/0.0523

+/0.065

+/0.0746

+/0.071

+/0.0748

+/0.120

+/0.0256

+/0.0239

+/0.994

+/0.113

+/0.0236

+/0.0583 362 Injun Hollow Road Notes:

The Qualifiers in this report are defined as follows :

Sample ID:

Receive Date:

Client Sample ID:

Matrix:

Collect Date:

Collector:

Moisture:

Batch

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

6.49%

0.155 0.182 0.338 0.084 0.0587 0.0445 0.0456 0.116 0.141 0.128 0.0648 0.0876 0.0432 0.041 0.356 0.084 0.0439 0.0441 The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GLRADA021 09/15/05 463010 1501 TC1 Method Description Analyst Date Time Prep Batch M

The following Analytical Methods were performed Method Description

+/0.206

+/0.101

+/0.319

+/0.111

+/0.0381

+/0.0856

+/0.0512

+/0.0637

+/0.0732

+/0.0696

+/0.0733

+/0.118

+/0.025

+/0.0234

+/0.974

+/0.111

+/0.0232

+/0.0572 TPU Uncertainty Vol. Recv.:

1 EML HASL 300, 4.5.2.3 1

LC MDA Page 43 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Parameter Result Units Qualifier AnalystDate Time DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417009 95270003016F YANK01204 Project:

YANK001 Client ID:

362 Injun Hollow Road Sample ID:

Client Sample ID:

Batch E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

M TPU Uncertainty Vol. Recv.:

LC MDA The above sample is reported on a dry weight basis.

Page 44 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier AnalystDate Time Gamma,SolidFSS GAM & ALL FSS 463112 1714 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium228 Americium241 Bismuth212 Bismuth214 Cesium134 Cesium137 Cobalt60 Europium152 Europium154 Europium155 Lead212 Lead214 Manganese54 Niobium94 Potassium40 Radium226 Silver108m Thallium208 10/10/05 MJH1 U

UUI U

U U

U U

U U

0.0711 0.0906 0.160 0.0398 0.0285 0.0221 0.0248 0.0587 0.0716 0.0646 0.0323 0.0383 0.0228 0.0221 0.201 0.0398 0.020 0.0196 DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417010 TS 07SEP05 14SEP05 95270003017F YANK01204 Project:

YANK001 Client ID:

Client 0.991 0.0558 0.741 0.948 0.00 1.21 0.00231 0.0249 0.0408 0.0411 1.01 1.10 0.0154 0.0397 12.0 0.948 0.00558 0.308

+/0.226

+/0.101

+/0.311

+/0.140

+/0.0437

+/0.117

+/0.030

+/0.0685

+/0.0828

+/0.0742

+/0.119

+/0.160

+/0.0264

+/0.0404

+/1.25

+/0.140

+/0.0245

+/0.0566 362 Injun Hollow Road Notes:

The Qualifiers in this report are defined as follows :

Sample ID:

Receive Date:

Client Sample ID:

Matrix:

Collect Date:

Collector:

Moisture:

Batch

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

7.26%

0.153 0.187 0.340 0.0842 0.0602 0.0469 0.0539 0.123 0.155 0.133 0.0669 0.0802 0.0485 0.0465 0.444 0.0842 0.0419 0.0417 The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GLRADA021 09/15/05 463010 1501 TC1 Method Description Analyst Date Time Prep Batch M

The following Analytical Methods were performed Method Description

+/0.222

+/0.0989

+/0.304

+/0.138

+/0.0429

+/0.114

+/0.0294

+/0.0671

+/0.0811

+/0.0727

+/0.117

+/0.156

+/0.0259

+/0.0396

+/1.22

+/0.138

+/0.0241

+/0.0554 TPU Uncertainty Vol. Recv.:

1 EML HASL 300, 4.5.2.3 1

LC MDA Page 45 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Parameter Result Units Qualifier AnalystDate Time DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417010 95270003017F YANK01204 Project:

YANK001 Client ID:

362 Injun Hollow Road Sample ID:

Client Sample ID:

Batch E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

M TPU Uncertainty Vol. Recv.:

LC MDA The above sample is reported on a dry weight basis.

Page 46 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier AnalystDate Time Gamma,SolidFSS GAM & ALL FSS 463112 1715 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium228 Americium241 Bismuth212 Bismuth214 Cesium134 Cesium137 Cobalt60 Europium152 Europium154 Europium155 Lead212 Lead214 Manganese54 Niobium94 Potassium40 Radium226 Silver108m Thallium208 10/10/05 MJH1 U

U U

U U

U U

U U

0.0658 0.113 0.137 0.0318 0.0231 0.0187 0.0195 0.0482 0.0548 0.0572 0.0278 0.0363 0.0203 0.0167 0.176 0.0318 0.0158 0.0169 DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417011 TS 06SEP05 14SEP05 95270003001F YANK01204 Project:

YANK001 Client ID:

Client 1.05 0.0926 0.904 1.13 0.0397 0.609 0.0155 0.025 0.0391 0.0512 1.21 1.25 0.00598 0.0014 12.6 1.13 0.00077 0.352

+/0.216

+/0.139

+/0.312

+/0.150

+/0.0261

+/0.0773

+/0.0223

+/0.0659

+/0.0709

+/0.0651

+/0.130

+/0.152

+/0.0257

+/0.0233

+/1.29

+/0.150

+/0.0187

+/0.0626 362 Injun Hollow Road Notes:

The Qualifiers in this report are defined as follows :

Sample ID:

Receive Date:

Client Sample ID:

Matrix:

Collect Date:

Collector:

Moisture:

Batch

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

13.6%

0.140 0.233 0.291 0.0672 0.0488 0.0394 0.0424 0.100 0.119 0.118 0.0574 0.0754 0.043 0.0353 0.385 0.0672 0.0331 0.0358 The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GLRADA021 09/15/05 463010 1501 TC1 Method Description Analyst Date Time Prep Batch M

The following Analytical Methods were performed Method Description

+/0.212

+/0.136

+/0.306

+/0.147

+/0.0255

+/0.0758

+/0.0218

+/0.0646

+/0.0695

+/0.0638

+/0.128

+/0.149

+/0.0252

+/0.0228

+/1.26

+/0.147

+/0.0184

+/0.0614 TPU Uncertainty Vol. Recv.:

1 EML HASL 300, 4.5.2.3 1

LC MDA Page 47 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Parameter Result Units Qualifier AnalystDate Time DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417011 95270003001F YANK01204 Project:

YANK001 Client ID:

362 Injun Hollow Road Sample ID:

Client Sample ID:

Batch E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

M TPU Uncertainty Vol. Recv.:

LC MDA The above sample is reported on a dry weight basis.

Page 48 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier AnalystDate Time Gamma,SolidFSS GAM & ALL FSS 463112 1715 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium228 Americium241 Bismuth212 Bismuth214 Cesium134 Cesium137 Cobalt60 Europium152 Europium154 Europium155 Lead212 Lead214 Manganese54 Niobium94 Potassium40 Radium226 Silver108m Thallium208 10/10/05 MJH1 U

U U

U U

U U

U U

0.0871 0.0429 0.210 0.0495 0.0397 0.0274 0.0286 0.0722 0.0794 0.0687 0.0389 0.0548 0.0274 0.0276 0.244 0.0495 0.0262 0.0275 DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417012 TS 06SEP05 14SEP05 95270003002F YANK01204 Project:

YANK001 Client ID:

Client 1.33 0.0426 1.42 1.18 0.0815 0.575 0.00725 0.0393 0.067 0.0639 1.19 1.20 0.000401 0.025 10.7 1.18 0.00536 0.398

+/0.307

+/0.0522

+/0.557

+/0.173

+/0.0591

+/0.0805

+/0.034

+/0.088

+/0.101

+/0.0805

+/0.159

+/0.171

+/0.0377

+/0.0322

+/1.23

+/0.173

+/0.0312

+/0.0833 362 Injun Hollow Road Notes:

The Qualifiers in this report are defined as follows :

Sample ID:

Receive Date:

Client Sample ID:

Matrix:

Collect Date:

Collector:

Moisture:

Batch

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

8.13%

0.189 0.088 0.448 0.105 0.0837 0.0584 0.0628 0.151 0.174 0.141 0.0808 0.114 0.0588 0.0585 0.544 0.105 0.055 0.0584 The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GLRADA021 09/15/05 463010 1501 TC1 Method Description Analyst Date Time Prep Batch M

The following Analytical Methods were performed Method Description

+/0.300

+/0.0511

+/0.546

+/0.169

+/0.0579

+/0.0788

+/0.0333

+/0.0863

+/0.0986

+/0.0789

+/0.156

+/0.168

+/0.0369

+/0.0315

+/1.20

+/0.169

+/0.0305

+/0.0816 TPU Uncertainty Vol. Recv.:

1 EML HASL 300, 4.5.2.3 1

LC MDA Page 49 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Parameter Result Units Qualifier AnalystDate Time DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417012 95270003002F YANK01204 Project:

YANK001 Client ID:

362 Injun Hollow Road Sample ID:

Client Sample ID:

Batch E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

M TPU Uncertainty Vol. Recv.:

LC MDA The above sample is reported on a dry weight basis.

Page 50 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier AnalystDate Time Gamma,SolidFSS GAM & ALL FSS 463112 1716 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium228 Americium241 Bismuth212 Bismuth214 Cesium134 Cesium137 Cobalt60 Europium152 Europium154 Europium155 Lead212 Lead214 Manganese54 Niobium94 Potassium40 Radium226 Silver108m Thallium208 10/10/05 MJH1 U

U U

U U

U U

U U

0.0944 0.114 0.201 0.0544 0.0335 0.0308 0.029 0.0764 0.0716 0.076 0.0468 0.051 0.0283 0.0259 0.217 0.0544 0.0288 0.0305 DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417013 TS 06SEP05 14SEP05 95270003004F YANK01204 Project:

YANK001 Client ID:

Client 1.12 0.0318 1.03 0.980 0.0174 1.83 0.0603 0.0226 0.0517 0.0359 1.13 1.17 0.0159 0.0141 9.76 0.980 0.017 0.327

+/0.247

+/0.152

+/0.394

+/0.162

+/0.0402

+/0.124

+/0.0781

+/0.0987

+/0.094

+/0.0907

+/0.107

+/0.147

+/0.0383

+/0.0349

+/1.14

+/0.162

+/0.0361

+/0.0815 362 Injun Hollow Road Notes:

The Qualifiers in this report are defined as follows :

Sample ID:

Receive Date:

Client Sample ID:

Matrix:

Collect Date:

Collector:

Moisture:

Batch

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

19.1%

0.205 0.236 0.433 0.115 0.0715 0.0653 0.0642 0.160 0.160 0.157 0.0967 0.107 0.061 0.0553 0.496 0.115 0.0603 0.0645 The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GLRADA021 09/15/05 463010 1501 TC1 Method Description Analyst Date Time Prep Batch M

The following Analytical Methods were performed Method Description

+/0.242

+/0.149

+/0.386

+/0.158

+/0.0394

+/0.121

+/0.0765

+/0.0967

+/0.0921

+/0.0888

+/0.105

+/0.144

+/0.0376

+/0.0342

+/1.12

+/0.158

+/0.0354

+/0.0799 TPU Uncertainty Vol. Recv.:

1 EML HASL 300, 4.5.2.3 1

LC MDA Page 51 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Parameter Result Units Qualifier AnalystDate Time DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417013 95270003004F YANK01204 Project:

YANK001 Client ID:

362 Injun Hollow Road Sample ID:

Client Sample ID:

Batch E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

M TPU Uncertainty Vol. Recv.:

LC MDA The above sample is reported on a dry weight basis.

Page 52 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier AnalystDate Time Gamma,SolidFSS GAM & ALL FSS 463112 1716 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium228 Americium241 Bismuth212 Bismuth214 Cesium134 Cesium137 Cobalt60 Europium152 Europium154 Europium155 Lead212 Lead214 Manganese54 Niobium94 Potassium40 Radium226 Silver108m Thallium208 10/10/05 MJH1 U

UUI U

U U

U U

U UUI 0.0599 0.0753 0.134 0.0335 0.0219 0.0174 0.0201 0.0481 0.0551 0.0525 0.0267 0.0336 0.0167 0.0165 0.195 0.0335 0.0173 0.0198 DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417014 TS 06SEP05 14SEP05 95270003005F YANK01204 Project:

YANK001 Client ID:

Client 0.812 0.00449 0.571 0.597 0.00 0.361 0.0223 0.0671 0.00352 0.0657 0.852 0.847 0.0216 0.00176 9.82 0.597 0.00 0.271

+/0.204

+/0.0968

+/0.257

+/0.0979

+/0.0424

+/0.050

+/0.0215

+/0.0533

+/0.067

+/0.0554

+/0.0652

+/0.0929

+/0.0348

+/0.0197

+/0.883

+/0.0979

+/0.0392

+/0.0465 362 Injun Hollow Road Notes:

The Qualifiers in this report are defined as follows :

Sample ID:

Receive Date:

Client Sample ID:

Matrix:

Collect Date:

Collector:

Moisture:

Batch

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

5.26%

0.130 0.156 0.289 0.0713 0.0469 0.0373 0.0442 0.101 0.121 0.109 0.0556 0.0707 0.0363 0.0353 0.429 0.0713 0.0365 0.042 The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GLRADA021 09/15/05 463010 1501 TC1 Method Description Analyst Date Time Prep Batch M

The following Analytical Methods were performed Method Description

+/0.199

+/0.0949

+/0.252

+/0.096

+/0.0415

+/0.049

+/0.021

+/0.0522

+/0.0657

+/0.0542

+/0.0639

+/0.091

+/0.0341

+/0.0193

+/0.865

+/0.096

+/0.0384

+/0.0456 TPU Uncertainty Vol. Recv.:

1 EML HASL 300, 4.5.2.3 1

LC MDA Page 53 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Parameter Result Units Qualifier AnalystDate Time DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417014 95270003005F YANK01204 Project:

YANK001 Client ID:

362 Injun Hollow Road Sample ID:

Client Sample ID:

Batch E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

M TPU Uncertainty Vol. Recv.:

LC MDA The above sample is reported on a dry weight basis.

Page 54 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier AnalystDate Time Gamma,SolidFSS GAM & ALL FSS 463112 1717 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium228 Americium241 Bismuth212 Bismuth214 Cesium134 Cesium137 Cobalt60 Europium152 Europium154 Europium155 Lead212 Lead214 Manganese54 Niobium94 Potassium40 Radium226 Silver108m Thallium208 10/10/05 MJH1 U

UUI U

U U

UUI U

U U

0.0797 0.026 0.162 0.0391 0.028 0.0228 0.0232 0.0497 0.0709 0.0414 0.0294 0.0405 0.0252 0.019 0.192 0.0391 0.0191 0.0219 DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417015 TS 06SEP05 14SEP05 95270003006F YANK01204 Project:

YANK001 Client ID:

Client 0.965 0.00226 0.812 0.945 0.00 0.509 0.00226 0.0493 0.0277 0.00 1.11 1.00 0.020 0.00397 10.5 0.945 0.0101 0.331

+/0.255

+/0.0308

+/0.393

+/0.147

+/0.0471

+/0.0738

+/0.0284

+/0.0646

+/0.0904

+/0.0673

+/0.138

+/0.146

+/0.047

+/0.0261

+/1.13

+/0.147

+/0.0217

+/0.0702 362 Injun Hollow Road Notes:

The Qualifiers in this report are defined as follows :

Sample ID:

Receive Date:

Client Sample ID:

Matrix:

Collect Date:

Collector:

Moisture:

Batch

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

8.68%

0.172 0.0536 0.347 0.0832 0.0596 0.0485 0.0512 0.105 0.155 0.086 0.0612 0.0848 0.0538 0.0406 0.432 0.0832 0.0402 0.0464 The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GLRADA021 09/15/05 463010 1501 TC1 Method Description Analyst Date Time Prep Batch M

The following Analytical Methods were performed Method Description

+/0.250

+/0.0302

+/0.386

+/0.144

+/0.0461

+/0.0723

+/0.0278

+/0.0633

+/0.0886

+/0.0659

+/0.135

+/0.143

+/0.046

+/0.0255

+/1.10

+/0.144

+/0.0212

+/0.0688 TPU Uncertainty Vol. Recv.:

1 EML HASL 300, 4.5.2.3 1

LC MDA Page 55 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Parameter Result Units Qualifier AnalystDate Time DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417015 95270003006F YANK01204 Project:

YANK001 Client ID:

362 Injun Hollow Road Sample ID:

Client Sample ID:

Batch E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

M TPU Uncertainty Vol. Recv.:

LC MDA The above sample is reported on a dry weight basis.

Page 56 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Rad Gamma Spec Analysis Parameter Result Units Qualifier AnalystDate Time Gamma,SolidFSS GAM & ALL FSS 463112 1717 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Actinium228 Americium241 Bismuth212 Bismuth214 Cesium134 Cesium137 Cobalt60 Europium152 Europium154 Europium155 Lead212 Lead214 Manganese54 Niobium94 Potassium40 Radium226 Silver108m Thallium208 10/10/05 MJH1 U

UUI UUI U

U U

U U

U 0.0562 0.0989 0.127 0.0326 0.0222 0.0199 0.0212 0.0464 0.0472 0.0628 0.0294 0.0333 0.0187 0.0159 0.153 0.0326 0.0155 0.0181 DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417016 TS 06SEP05 14SEP05 95270003009F YANK01204 Project:

YANK001 Client ID:

Client 1.05 0.0271 0.876 0.947 0.00 0.804 0.00 0.00478 0.0154 0.0822 0.998 1.19 0.00369 0.0029 11.4 0.947 0.0235 0.263

+/0.178

+/0.129

+/0.385

+/0.0998

+/0.0391

+/0.057

+/0.0356

+/0.0539

+/0.0601

+/0.0685

+/0.0723

+/0.112

+/0.0224

+/0.0193

+/0.872

+/0.0998

+/0.0207

+/0.0517 362 Injun Hollow Road Notes:

The Qualifiers in this report are defined as follows :

Sample ID:

Receive Date:

Client Sample ID:

Matrix:

Collect Date:

Collector:

Moisture:

Batch

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

7.74%

0.120 0.205 0.269 0.0687 0.0467 0.0417 0.0453 0.0969 0.102 0.130 0.0608 0.0697 0.0396 0.0334 0.335 0.0687 0.0325 0.0381 The following Prep Methods were performed Dry Soil Prep Dry Soil Prep GLRADA021 09/15/05 463010 1501 TC1 Method Description Analyst Date Time Prep Batch M

The following Analytical Methods were performed Method Description

+/0.174

+/0.126

+/0.377

+/0.0978

+/0.0383

+/0.0559

+/0.0349

+/0.0528

+/0.0589

+/0.0671

+/0.0709

+/0.110

+/0.022

+/0.019

+/0.855

+/0.0978

+/0.0202

+/0.0507 TPU Uncertainty Vol. Recv.:

1 EML HASL 300, 4.5.2.3 1

LC MDA Page 57 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Parameter Result Units Qualifier AnalystDate Time DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417016 95270003009F YANK01204 Project:

YANK001 Client ID:

362 Injun Hollow Road Sample ID:

Client Sample ID:

Batch E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

M TPU Uncertainty Vol. Recv.:

LC MDA The above sample is reported on a dry weight basis.

Page 58 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Rad Alpha Spec Analysis Rad Gamma Spec Analysis Rad Gas Flow Proportional Counting Rad Liquid Scintillation Analysis Parameter Result Units Qualifier AnalystDate Time Alphaspec Am241, Cm, Solid ALL FSS Alphaspec Pu, SolidALL FSS Liquid Scint Pu241, SolidALL FSS Gamma,SolidFSS GAM & ALL FSS GFPC, Sr90, solidALL FSS LSC, Tritium Dist, SolidHTD2,ALL FSS Liquid Scint C14, Solid All,FSS 467822 467823 467827 463112 467346 467508 1538 1538 1047 1718 2222 1352 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Americium241 Curium242 Curium243/244 Plutonium238 Plutonium239/240 Plutonium241 Actinium228 Americium241 Bismuth212 Bismuth214 Cesium134 Cesium137 Cobalt60 Europium152 Europium154 Europium155 Lead212 Lead214 Manganese54 Niobium94 Potassium40 Radium226 Silver108m Thallium208 Strontium90 Tritium 10/08/05 10/08/05 10/11/05 10/10/05 10/06/05 10/11/05 BJB1 BJB1 BJB1 MJH1 EXW1 BXF1 U

U U

U U

U U

UUI U

U U

U UUI U

U U

U 0.0912 0.0524 0.0792 0.0563 0.184 7.45 0.0671 0.0717 0.155 0.0394 0.0269 0.0195 0.0243 0.0527 0.0636 0.0585 0.0302 0.0392 0.0195 0.0196 0.190 0.0394 0.019 0.0187 0.0102 5.14 DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417017 TS 06SEP05 14SEP05 95270003003F YANK01204 Project:

YANK001 Client ID:

Client 0.0905 0.0169 0.101 0.0365 0.133 5.83 1.15 0.0385 0.645 0.969 0.00 0.841 0.0386 0.0658 0.00216 0.0131 1.01 1.09 0.00 0.0047 11.0 0.969 0.00166 0.281 0.00382 0.611

+/0.131

+/0.0673

+/0.129

+/0.0824

+/0.123

+/8.59

+/0.229

+/0.0842

+/0.414

+/0.159

+/0.0326

+/0.111

+/0.0267

+/0.0746

+/0.0789

+/0.0712

+/0.118

+/0.155

+/0.0704

+/0.0239

+/1.13

+/0.159

+/0.0237

+/0.0618

+/0.0107

+/6.09 362 Injun Hollow Road Sample ID:

Receive Date:

Client Sample ID:

Matrix:

Collect Date:

Collector:

Moisture:

Batch 12.7%

0.259 0.193 0.235 0.190 0.444 15.5 0.143 0.148 0.328 0.0827 0.0566 0.0412 0.0521 0.110 0.137 0.121 0.0627 0.0818 0.0416 0.0412 0.414 0.0827 0.0397 0.0396 0.0212 10.7 M

+/0.131

+/0.0673

+/0.129

+/0.0825

+/0.124

+/8.62

+/0.225

+/0.0825

+/0.405

+/0.156

+/0.032

+/0.109

+/0.0261

+/0.0731

+/0.0773

+/0.0697

+/0.115

+/0.152

+/0.069

+/0.0234

+/1.11

+/0.156

+/0.0232

+/0.0606

+/0.0107

+/6.09 TPU Uncertainty Vol. Recv.:

1 2

3 4

5 6

LC MDA Page 59 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Rad Liquid Scintillation Analysis Parameter Result Units Qualifier AnalystDate Time Liquid Scint C14, Solid All,FSS Liquid Scint Fe55, SolidALL FSS Liquid Scint Ni63, SolidALL FSS Liquid Scint Tc99, SolidALL FSS 464786 464797 464799 464785 0752 0410 1931 0500 pCi/g pCi/g pCi/g pCi/g Carbon14 Iron55 Nickel63 Technetium99 09/22/05 09/24/05 09/24/05 09/27/05 SLN1 BXF1 BXF1 BXF1 U

U U

0.0873 34.4 7.12 0.168 DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417017 95270003003F YANK01204 Project:

YANK001 Client ID:

0.125 33.6 5.74 0.396

+/0.106

+/50.1

+/8.17

+/0.171 362 Injun Hollow Road Surrogate/Tracer recovery Recovery%

Test Acceptable Limits Sample ID:

Client Sample ID:

Batch Americium243 Plutonium242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, SolidALL FSS Liquid Scint Pu241, SolidALL FS GFPC, Sr90, solidALL FSS Liquid Scint Fe55, SolidALL FS Liquid Scint Ni63, SolidALL FS 94 100 89 65 79 94 (15%125%)

(15%125%)

(25%125%)

(25%125%)

(15%125%)

(25%125%)

0.177 71.0 14.9 0.348 The following Prep Methods were performed Ash Soil Prep Dry Soil Prep Ash Soil Prep, GLRADA021B Dry Soil Prep GLRADA021 09/16/05 09/15/05 463017 463013 1531 1456 TC1 TC1 Method Description Analyst Date Time Prep Batch M

The following Analytical Methods were performed Method Description

+/0.106

+/50.1

+/8.17

+/0.171 TPU Uncertainty Vol. Recv.:

1 2

3 4

5 6

7 8

9 10 DOE EML HASL300, Am05RC Modified DOE EML HASL300, Pu11RC Modified DOE EML HASL300, Pu11RC Modified EML HASL 300, 4.5.2.3 EPA 905.0 Modified EPA 906.0 Modified EPA EERF C01 Modified DOE RESL Fe1, Modified DOE RESL Ni1, Modified DOE EML HASL300, Tc02RC Modified 7

8 9

10 LC MDA Page 60 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Parameter Result Units Qualifier AnalystDate Time DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417017 95270003003F YANK01204 Project:

YANK001 Client ID:

362 Injun Hollow Road Notes:

The Qualifiers in this report are defined as follows :

Sample ID:

Client Sample ID:

Batch

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

Carrier/Tracer Recovery Liquid Scint Tc99, SolidALL FS 88 (15%125%)

M TPU Uncertainty Vol. Recv.:

LC MDA The above sample is reported on a dry weight basis.

Page 61 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Rad Alpha Spec Analysis Rad Gamma Spec Analysis Rad Gas Flow Proportional Counting Rad Liquid Scintillation Analysis Parameter Result Units Qualifier AnalystDate Time Alphaspec Am241, Cm, Solid ALL FSS Alphaspec Pu, SolidALL FSS Liquid Scint Pu241, SolidALL FSS Gamma,SolidFSS GAM & ALL FSS GFPC, Sr90, solidALL FSS LSC, Tritium Dist, SolidHTD2,ALL FSS Liquid Scint C14, Solid All,FSS 467822 467823 467827 463112 467346 467508 1121 1538 1103 1718 2222 1424 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Americium241 Curium242 Curium243/244 Plutonium238 Plutonium239/240 Plutonium241 Actinium228 Americium241 Bismuth212 Bismuth214 Cesium134 Cesium137 Cobalt60 Europium152 Europium154 Europium155 Lead212 Lead214 Manganese54 Niobium94 Potassium40 Radium226 Silver108m Thallium208 Strontium90 Tritium 10/08/05 10/08/05 10/11/05 10/10/05 10/06/05 10/11/05 BJB1 BJB1 BJB1 MJH1 EXW1 BXF1 U

U U

U U

U U

U U

U U

U U

U U

U U

0.0792 0.0407 0.071 0.0358 0.143 7.51 0.0828 0.117 0.159 0.0464 0.0291 0.0239 0.0262 0.0659 0.0652 0.0725 0.042 0.0499 0.0266 0.0225 0.231 0.0464 0.0239 0.0254 0.0112 4.77 DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417018 TS 06SEP05 14SEP05 95270003007F YANK01204 Project:

YANK001 Client ID:

Client 0.0321 0.00856 0.0636 0.0239 0.0578 10.4 0.694 0.0606 0.774 0.756 0.0392 0.635 0.0153 0.0997 0.0209 0.0424 0.929 0.959 0.0157 0.0086 7.72 0.756 0.0113 0.268 0.016 2.79

+/0.0411

+/0.0719

+/0.110

+/0.0634

+/0.105

+/8.42

+/0.181

+/0.144

+/0.353

+/0.107

+/0.0319

+/0.0858

+/0.0299

+/0.109

+/0.0813

+/0.0873

+/0.097

+/0.151

+/0.0355

+/0.0264

+/0.928

+/0.107

+/0.0287

+/0.0662

+/0.0125

+/5.82 362 Injun Hollow Road Sample ID:

Receive Date:

Client Sample ID:

Matrix:

Collect Date:

Collector:

Moisture:

Batch 10.3%

0.243 0.178 0.226 0.157 0.371 15.6 0.179 0.242 0.347 0.0988 0.0624 0.0514 0.0577 0.139 0.145 0.150 0.0874 0.105 0.0571 0.0481 0.513 0.0988 0.0506 0.0541 0.0234 9.93 M

+/0.0414

+/0.072

+/0.110

+/0.0634

+/0.105

+/8.53

+/0.178

+/0.141

+/0.346

+/0.105

+/0.0312

+/0.0841

+/0.0293

+/0.107

+/0.0797

+/0.0856

+/0.0951

+/0.148

+/0.0348

+/0.0259

+/0.909

+/0.105

+/0.0282

+/0.0649

+/0.0125

+/5.82 TPU Uncertainty Vol. Recv.:

1 2

3 4

5 6

LC MDA Page 62 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Rad Liquid Scintillation Analysis Parameter Result Units Qualifier AnalystDate Time Liquid Scint C14, Solid All,FSS Liquid Scint Fe55, SolidALL FSS Liquid Scint Ni63, SolidALL FSS Liquid Scint Tc99, SolidALL FSS 464786 464797 464799 464785 0926 0427 1948 0517 pCi/g pCi/g pCi/g pCi/g Carbon14 Iron55 Nickel63 Technetium99 09/22/05 09/24/05 09/24/05 09/27/05 SLN1 BXF1 BXF1 BXF1 U

U U

U 0.0826 39.7 6.98 0.178 DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417018 95270003007F YANK01204 Project:

YANK001 Client ID:

0.0421 8.63 1.86 0.201

+/0.0977

+/59.0

+/8.21

+/0.170 362 Injun Hollow Road Surrogate/Tracer recovery Recovery%

Test Acceptable Limits Sample ID:

Client Sample ID:

Batch Americium243 Plutonium242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, SolidALL FSS Liquid Scint Pu241, SolidALL FS GFPC, Sr90, solidALL FSS Liquid Scint Fe55, SolidALL FS Liquid Scint Ni63, SolidALL FS 87 85 88 49 75 95 (15%125%)

(15%125%)

(25%125%)

(25%125%)

(15%125%)

(25%125%)

0.167 81.9 14.6 0.369 The following Prep Methods were performed Ash Soil Prep Dry Soil Prep Ash Soil Prep, GLRADA021B Dry Soil Prep GLRADA021 09/16/05 09/15/05 463017 463013 1531 1456 TC1 TC1 Method Description Analyst Date Time Prep Batch M

The following Analytical Methods were performed Method Description

+/0.0977

+/59.0

+/8.21

+/0.170 TPU Uncertainty Vol. Recv.:

1 2

3 4

5 6

7 8

9 10 DOE EML HASL300, Am05RC Modified DOE EML HASL300, Pu11RC Modified DOE EML HASL300, Pu11RC Modified EML HASL 300, 4.5.2.3 EPA 905.0 Modified EPA 906.0 Modified EPA EERF C01 Modified DOE RESL Fe1, Modified DOE RESL Ni1, Modified DOE EML HASL300, Tc02RC Modified 7

8 9

10 LC MDA Page 63 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Parameter Result Units Qualifier AnalystDate Time DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417018 95270003007F YANK01204 Project:

YANK001 Client ID:

362 Injun Hollow Road Notes:

The Qualifiers in this report are defined as follows :

Sample ID:

Client Sample ID:

Batch

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

Carrier/Tracer Recovery Liquid Scint Tc99, SolidALL FS 83 (15%125%)

M TPU Uncertainty Vol. Recv.:

LC MDA The above sample is reported on a dry weight basis.

Page 64 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Rad Alpha Spec Analysis Rad Gamma Spec Analysis Rad Gas Flow Proportional Counting Rad Liquid Scintillation Analysis Parameter Result Units Qualifier AnalystDate Time Alphaspec Am241, Cm, Solid ALL FSS Alphaspec Pu, SolidALL FSS Liquid Scint Pu241, SolidALL FSS Gamma,SolidFSS GAM & ALL FSS GFPC, Sr90, solidALL FSS LSC, Tritium Dist, SolidHTD2,ALL FSS Liquid Scint C14, Solid All,FSS 467822 467823 467827 463112 467346 467508 1121 1537 1120 1719 2222 2119 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Americium241 Curium242 Curium243/244 Plutonium238 Plutonium239/240 Plutonium241 Actinium228 Americium241 Bismuth212 Bismuth214 Cesium134 Cesium137 Cobalt60 Europium152 Europium154 Europium155 Lead212 Lead214 Manganese54 Niobium94 Potassium40 Radium226 Silver108m Thallium208 Strontium90 Tritium 10/08/05 10/08/05 10/11/05 10/10/05 10/06/05 10/09/05 BJB1 BJB1 BJB1 MJH1 EXW1 BXF1 U

U U

U U

U U

U U

U U

U U

U U

U 0.0356 0.00 0.0505 0.190 0.157 7.38 0.140 0.0527 0.339 0.0697 0.0482 0.0399 0.0422 0.0979 0.113 0.0872 0.0509 0.067 0.0352 0.031 0.367 0.0697 0.0334 0.0371 0.00775 4.63 DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417019 TS 06SEP05 14SEP05 95270003010F YANK01204 Project:

YANK001 Client ID:

Client 0.0932 0.0359 0.0163 0.0668 0.0361 2.67 1.25 0.0126 1.28 0.990 0.0502 1.28 0.0273 0.0819 0.0586 0.0823 1.40 1.32 0.0293 0.0253 12.6 0.990 0.00432 0.455 0.0242 5.11

+/0.111

+/0.0704

+/0.0649

+/0.153

+/0.131

+/8.66

+/0.392

+/0.0631

+/0.607

+/0.220

+/0.0657

+/0.155

+/0.0488

+/0.110

+/0.143

+/0.105

+/0.170

+/0.219

+/0.0457

+/0.0394

+/1.50

+/0.220

+/0.0417

+/0.117

+/0.00947

+/5.78 362 Injun Hollow Road Sample ID:

Receive Date:

Client Sample ID:

Matrix:

Collect Date:

Collector:

Moisture:

Batch 14.6%

0.156 0.0973 0.186 0.471 0.404 15.4 0.298 0.108 0.712 0.147 0.102 0.084 0.0909 0.204 0.243 0.180 0.106 0.140 0.0751 0.0658 0.800 0.147 0.070 0.0782 0.0163 9.67 M

+/0.112

+/0.0705

+/0.0649

+/0.153

+/0.131

+/8.67

+/0.385

+/0.0618

+/0.595

+/0.215

+/0.0644

+/0.152

+/0.0478

+/0.108

+/0.140

+/0.103

+/0.166

+/0.215

+/0.0448

+/0.0387

+/1.47

+/0.215

+/0.0409

+/0.115

+/0.00948

+/5.78 TPU Uncertainty Vol. Recv.:

1 2

3 4

5 6

LC MDA Page 65 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Rad Liquid Scintillation Analysis Parameter Result Units Qualifier AnalystDate Time Liquid Scint C14, Solid All,FSS Liquid Scint Fe55, SolidALL FSS Liquid Scint Ni63, SolidALL FSS Liquid Scint Tc99, SolidALL FSS 464786 464797 464799 464785 1100 0444 2005 0534 pCi/g pCi/g pCi/g pCi/g Carbon14 Iron55 Nickel63 Technetium99 09/22/05 09/24/05 09/24/05 09/27/05 SLN1 BXF1 BXF1 BXF1 U

U U

0.0808 36.7 7.22 0.177 DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417019 95270003010F YANK01204 Project:

YANK001 Client ID:

0.109 3.09 4.83 0.604

+/0.0981

+/54.3

+/8.34

+/0.189 362 Injun Hollow Road Surrogate/Tracer recovery Recovery%

Test Acceptable Limits Sample ID:

Client Sample ID:

Batch Americium243 Plutonium242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, SolidALL FSS Liquid Scint Pu241, SolidALL FS GFPC, Sr90, solidALL FSS Liquid Scint Fe55, SolidALL FS Liquid Scint Ni63, SolidALL FS 81 89 91 67 75 92 (15%125%)

(15%125%)

(25%125%)

(25%125%)

(15%125%)

(25%125%)

0.164 75.7 15.1 0.366 The following Prep Methods were performed Ash Soil Prep Dry Soil Prep Ash Soil Prep, GLRADA021B Dry Soil Prep GLRADA021 09/16/05 09/15/05 463017 463013 1531 1456 TC1 TC1 Method Description Analyst Date Time Prep Batch M

The following Analytical Methods were performed Method Description

+/0.0981

+/54.3

+/8.34

+/0.189 TPU Uncertainty Vol. Recv.:

1 2

3 4

5 6

7 8

9 10 DOE EML HASL300, Am05RC Modified DOE EML HASL300, Pu11RC Modified DOE EML HASL300, Pu11RC Modified EML HASL 300, 4.5.2.3 EPA 905.0 Modified EPA 906.0 Modified EPA EERF C01 Modified DOE RESL Fe1, Modified DOE RESL Ni1, Modified DOE EML HASL300, Tc02RC Modified 7

8 9

10 LC MDA Page 66 of 77

Certificate of Analysis GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Parameter Result Units Qualifier AnalystDate Time DF Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Company :

Haddam Neck Plant East Hampton, Connecticut 06424 October 13, 2005 Report Date:

Address :

Soils PO# 002332 Project:

145417019 95270003010F YANK01204 Project:

YANK001 Client ID:

362 Injun Hollow Road Notes:

The Qualifiers in this report are defined as follows :

Sample ID:

Client Sample ID:

Batch

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

Carrier/Tracer Recovery Liquid Scint Tc99, SolidALL FS 83 (15%125%)

M TPU Uncertainty Vol. Recv.:

LC MDA The above sample is reported on a dry weight basis.

Page 67 of 77

QUALITY CONTROL DATA Page 68 of 77

QC Summary GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Alpha Spec 467822 467823 Batch Batch Americium-241 Curium-242 Curium-243/244 Americium-241 Curium-242 Curium-243/244 Americium-241 Curium-242 Curium-243/244 Americium-241 Curium-242 Curium-243/244 Plutonium-238 Parmname Mr. Pete Hollenbeck

Contact:

Connecticut Yankee Atomic Power Client :

Haddam Neck Plant East Hampton, Connecticut October 13, 2005 Report Date:

Units pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Anlst Date Time BJB1 BJB1 10/08/05 10/11/05 15:38 14:16 QC

-0.0395

-0.00877

-0.0306 13.1

-0.00664 15.2

-0.0244

-0.0136 0.00 11.8 0.00 15.0

-0.0225 NOM Sample 0.0905 0.0169 0.101 0.0905 0.0169 0.101 0.0365 Range (0% - 100%)

(0% - 100%)

(0% - 100%)

(75%-125%)

(75%-125%)

(75%-125%)

(75%-125%)

(0% - 100%)

Qual U

U U

U U

U U

U U

QC1200948303 145417017 QC1200948305 QC1200948302 QC1200948304 145417017 QC1200948314 145417017 RPD%

REC%

104 99 92 96 12.6 15.3 12.8 15.7 DUP LCS MB MS DUP 145417 Workorder:

362 Injun Hollow Road U

U U

U U

U U

+/-0.131

+/-0.0673

+/-0.129

+/-0.131

+/-0.0673

+/-0.129

+/-0.046

+/-0.0172

+/-0.030

+/-1.17

+/-0.013

+/-1.26

+/-0.0544

+/-0.0189

+/-0.0544

+/-1.13

+/-0.0631

+/-1.27 Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

+/-0.131

+/-0.0673

+/-0.129

+/-0.131

+/-0.0673

+/-0.129

+/-0.0463

+/-0.0172

+/-0.0303

+/-1.97

+/-0.013

+/-2.22

+/-0.0545

+/-0.019

+/-0.0544

+/-1.82

+/-0.0631

+/-2.23 N/A N/A N/A N/A Page 1 of 9 Page 69 of 77

QC Summary GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Alpha Spec Rad Gamma Spec 467823 467827 463112 Batch Batch Batch Plutonium-239/240 Plutonium-238 Plutonium-239/240 Plutonium-238 Plutonium-239/240 Plutonium-238 Plutonium-239/240 Plutonium-241 Plutonium-241 Plutonium-241 Plutonium-241 Actinium-228 Parmname Units pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Anlst Date Time BJB1 MJH1 10/08/05 10/08/05 10/08/05 10/11/05 10/11/05 10/11/05 10/11/05 10/10/05 15:37 15:38 15:37 11:54 12:28 11:37 12:11 17:25 QC 0.0673 0.0182 10.3 0.0229

-0.113 0.0564 12.0

-1.87 101

-8.5 99.9 0.812 NOM Sample

-0.133 0.0365

-0.133

-5.83

-5.83 0.969 Range (0% - 100%)

(75%-125%)

(75%-125%)

(75%-125%)

(75%-125%)

(0% - 100%)

(75%-125%)

(75%-125%)

(0% - 100%)

Qual U

U U

U U

U U

QC1200948316 QC1200948313 QC1200948315 145417017 QC1200948318 145417017 QC1200948320 QC1200948317 QC1200948319 145417017 QC1200936935 145417001 RPD%

REC%

89 102 78 75 11.6 11.8 131 133 LCS MB MS DUP LCS MB MS DUP 145417 Workorder:

U U

U U

U

+/-0.0824

+/-0.123

+/-0.0824

+/-0.123

+/-8.59

+/-8.59

+/-0.286

+/-0.104

+/-0.0924

+/-0.122

+/-1.07

+/-0.0607

+/-0.108

+/-0.162

+/-1.26

+/-9.21

+/-12.1

+/-7.78

+/-12.0

+/-0.215 Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

+/-0.0825

+/-0.124

+/-0.0825

+/-0.124

+/-8.62

+/-8.62

+/-0.104

+/-0.0926

+/-0.122

+/-1.62

+/-0.0607

+/-0.109

+/-0.163

+/-1.94

+/-9.21

+/-17.7

+/-7.86

+/-17.4

+/-0.211 N/A N/A 18 Page 2 of 9 Page 70 of 77

QC Summary GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 463112 Batch Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Parmname Units pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Anlst Date Time QC

-0.0231 0.468 0.919 0.0135 1.55 0.00

-0.00881

-0.0262 0.0249 0.927 1.02 0.00343 0.0198 8.54 0.919

-0.00309 NOM Sample 0.0305 0.605 1.13 0.00 1.62 0.0403

-0.0406

-0.0161 0.0816 0.894 1.11 0.018 0.00549 9.17 1.13

-0.00168 Range (0% - 100%)

(0% - 100%)

(0% - 100%)

(0% - 20%)

(0% - 100%)

(0% - 100%)

(0% - 100%)

(0% - 100%)

(0% - 20%)

(0% - 20%)

(0% - 100%)

(0% - 100%)

(0% - 20%)

(0% - 100%)

(0% - 100%)

Qual U

U UUI U

U U

U U

U RPD%

REC%

145417 Workorder:

U UUI U

U U

U U

U U

+/-0.051

+/-0.546

+/-0.178

+/-0.064

+/-0.180

+/-0.040

+/-0.0963

+/-0.122

+/-0.0838

+/-0.119

+/-0.192

+/-0.0408

+/-0.0351

+/-1.13

+/-0.178

+/-0.0371

+/-0.146

+/-0.340

+/-0.139

+/-0.0296

+/-0.138

+/-0.0495

+/-0.0632

+/-0.0624

+/-0.065

+/-0.119

+/-0.156

+/-0.0229

+/-0.0181

+/-0.994

+/-0.139

+/-0.0213 Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

+/-0.280

+/-0.050

+/-0.535

+/-0.174

+/-0.0627

+/-0.176

+/-0.0392

+/-0.0944

+/-0.120

+/-0.0821

+/-0.117

+/-0.188

+/-0.040

+/-0.0344

+/-1.11

+/-0.174

+/-0.143

+/-0.333

+/-0.137

+/-0.0291

+/-0.135

+/-0.0485

+/-0.0619

+/-0.0611

+/-0.0637

+/-0.116

+/-0.153

+/-0.0225

+/-0.0178

+/-0.974

+/-0.137 N/A 26 21 148 4

42 N/A N/A 106 4

8 136 113 7

21 N/A Page 3 of 9 Page 71 of 77

QC Summary GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 463112 Batch Thallium-208 Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Parmname Units pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Anlst Date Time 10/10/05 11:27 QC 0.319 0.998 24.3 1.18 0.00375 0.194 10.1 15.2

-0.197 0.337

-0.148 0.295 0.014 0.182

-0.0783 0.0345 NOM Sample 0.323 Range (0% - 100%)

(75%-125%)

(75%-125%)

(75%-125%)

Qual U

U U

U U

U U

U U

U U

U QC1200936936 RPD%

REC%

100 107 107 24.4 9.39 14.3 LCS 145417 Workorder:

+/-0.083

+/-0.0622

+/-1.01

+/-0.972

+/-1.61

+/-0.370

+/-0.243

+/-0.628

+/-0.866

+/-0.426

+/-0.462

+/-0.465

+/-0.228

+/-0.305

+/-0.215

+/-0.179 Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

+/-0.0364

+/-0.0813

+/-0.0209

+/-0.061

+/-0.993

+/-0.952

+/-1.58

+/-0.363

+/-0.238

+/-0.616

+/-0.848

+/-0.418

+/-0.452

+/-0.456

+/-0.223

+/-0.299

+/-0.211

+/-0.176 1

Page 4 of 9 Page 72 of 77

QC Summary GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 463112 Batch Radium-226 Silver-108m Thallium-208 Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Parmname Units pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Anlst Date Time 10/10/05 17:19 QC 0.00375

-0.0313 0.0438 0.0454

-0.0224 0.0816 0.0459

-0.000772 0.00609 0.0144 0.000976 0.002

-0.0285 0.0217 0.022 NOM Sample Range (75%-125%)

Qual U

U U

U U

U U

U U

U U

U U

U U

QC1200936934 RPD%

REC%

MB 145417 Workorder:

+/-1.66

+/-0.370

+/-0.167

+/-0.205

+/-0.053

+/-0.075

+/-0.141

+/-0.0533

+/-0.0159

+/-0.0171

+/-0.00964

+/-0.0443

+/-0.0455

+/-0.037

+/-0.0413

+/-0.0318 Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

+/-1.63

+/-0.363

+/-0.164

+/-0.201

+/-0.0519

+/-0.0735

+/-0.138

+/-0.0523

+/-0.0156

+/-0.0167

+/-0.00945

+/-0.0434

+/-0.0446

+/-0.0362

+/-0.0405

+/-0.0312 Page 5 of 9 Page 73 of 77

QC Summary GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Rad Gas Flow Rad Liquid Scintillation 463112 467346 464785 Batch Batch Batch Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 Strontium-90 Strontium-90 Strontium-90 Strontium-90 Technetium-99 Technetium-99 Technetium-99 Parmname Units pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Anlst Date Time EXW1 BXF1 10/12/05 10/07/05 10/12/05 10/07/05 09/27/05 09/27/05 09/27/05 19:34 19:14 19:34 19:13 06:25 07:00 06:08 QC

-3.220E-05 0.00618 0.00 0.0459 0.00302 0.0256

-0.00366 1.21 0.00261 1.25 0.0721 11.3 0.194 NOM Sample

-0.00109

-0.00109 0.201 Range (0% - 100%)

(75%-125%)

(75%-125%)

(0% - 100%)

(75%-125%)

Qual U

U UUI U

U U

U U

U U

QC1200947127 145495001 QC1200947129 QC1200947126 QC1200947128 145495001 QC1200941137 145417018 QC1200941139 QC1200941136 RPD%

REC%

102 105 89 1.18 1.18 12.7 DUP LCS MB MS DUP LCS MB 145417 Workorder:

U U

U

+/-0.0095

+/-0.0095

+/-0.170

+/-0.0187

+/-0.015

+/-0.237

+/-0.0533

+/-0.0167

+/-0.0179

+/-0.0076

+/-0.0755

+/-0.00407

+/-0.117

+/-0.163

+/-0.432 Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

+/-0.0095

+/-0.0095

+/-0.170

+/-0.0183

+/-0.0147

+/-0.232

+/-0.0523

+/-0.0164

+/-0.0175

+/-0.0076

+/-0.0836

+/-0.00407

+/-0.123

+/-0.163

+/-0.513 N/A 0

Page 6 of 9 Page 74 of 77

QC Summary GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Liquid Scintillation 464785 464786 464797 464799 Batch Batch Batch Batch Technetium-99 Carbon-14 Carbon-14 Carbon-14 Carbon-14 Iron-55 Iron-55 Iron-55 Iron-55 Nickel-63 Nickel-63 Parmname Units pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Anlst Date Time SLN1 BXF1 BXF1 09/27/05 09/22/05 09/22/05 09/22/05 09/22/05 09/24/05 09/24/05 09/24/05 09/24/05 09/24/05 09/24/05 06:43 15:41 18:49 14:07 17:15 05:36 06:10 05:18 05:53 20:55 21:28 QC 11.5 0.0911 6.48

-0.0611 6.07

-7.41 698 20.3 737

-2.29 532 NOM Sample 0.201 0.125 0.125

-24.8

-24.8

-4.8 Range (75%-125%)

(0% - 100%)

(75%-125%)

(75%-125%)

(0% - 100%)

(75%-125%)

(75%-125%)

(0% - 100%)

(75%-125%)

Qual U

U U

U U

QC1200941138 145417018 QC1200941141 145417017 QC1200941143 QC1200941140 QC1200941142 145417017 QC1200941151 145258021 QC1200941153 QC1200941150 QC1200941152 145258021 QC1200941155 145258021 QC1200941157 RPD%

REC%

90 95 86 90 94 92 12.7 6.80 7.05 777 788 577 MS DUP LCS MB MS DUP LCS MB MS DUP LCS 145417 Workorder:

U U

U U

U U

+/-0.170

+/-0.106

+/-0.106

+/-49.7

+/-49.7

+/-7.84

+/-0.146

+/-0.466

+/-0.0952

+/-0.162

+/-0.0937

+/-0.171

+/-57.3

+/-74.7

+/-53.6

+/-75.1

+/-8.07

+/-23.8 Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

+/-0.170

+/-0.106

+/-0.106

+/-49.8

+/-49.8

+/-7.85

+/-0.146

+/-0.546

+/-0.0952

+/-0.191

+/-0.0937

+/-0.196

+/-57.3

+/-86.0

+/-53.6

+/-87.7

+/-8.07

+/-30.0 0

N/A N/A Page 7 of 9 Page 75 of 77

QC Summary GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Rad Liquid Scintillation 464799 467508 Batch Batch Nickel-63 Nickel-63 Tritium Tritium Tritium Tritium Parmname Units pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Anlst Date Time BXF1 09/24/05 09/24/05 10/10/05 10/13/05 10/10/05 10/13/05 20:38 21:11 04:53 02:10 04:21 01:38 QC 0.688 502 5.48 2.43 0.341 50.9 NOM Sample

-4.8 3.73 3.73 Range (75%-125%)

(0% - 100%)

(75%-125%)

(75%-125%)

Qual U

U U

QC1200941154 QC1200941156 145258021 QC1200947552 145495003 QC1200947554 QC1200947551 QC1200947553 145495003 Notes:

The Qualifiers in this report are defined as follows:

RPD%

REC%

86 80 76 582 3.03 67.2 MB MS DUP LCS MB MS 145417 Workorder:

B BD E

H J

U UI X

d h

Indicates the analyte is a surrogate compound.

Target analyte was detected in the sample as well as the associated blank.

Results below the MDC or low tracer recovery.

Concentration of the target analyte exceeds the instrument calibration range.

Analytical holding time exceeded.

Indicates an estimated value.

Target analyte was analyzed for but not detected above the MDL or LOD.

Uncertain identification for gamma spectroscopy.

Lab-specific qualifier-please see case narrative, data summary package or contact your project manager for details.

The 2:1 depletion requirement was not met for this sample Sample preparation or preservation holding time exceeded.

U U

U

+/-7.84

+/-6.27

+/-6.27

+/-8.18

+/-22.6

+/-5.58

+/-0.368

+/-0.435

+/-9.06 Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

Uncert:

TPU:

TPU:

TPU:

TPU:

TPU:

TPU:

+/-7.85

+/-6.27

+/-6.27

+/-8.18

+/-28.4

+/-5.58

+/-0.370

+/-0.435

+/-9.10 0

Page 8 of 9 Page 76 of 77

QC Summary GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Parmname Page 9 of 9 Units Anlst Date Time QC NOM Sample Range Qual RPD%

REC%

145417 Workorder:

N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

Page 77 of 77

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0003 RELEASE RECORD b Sample and Scan Area Data (9 Pages)

SAMPLE LOCATION SCANS 9527-0003 Log Date Log Time E600 S/N Probe S/N 12800 14415 13300 09/06/2005 2:19 PM 1109 1005 15800 17594 16300 09/06/2005 2:24 PM 1109 1005 18400 20336 20200 09/06/2005 2:27 PM 1109 1005 23300 25478 21000 09/06/2005 2:29 PM 1109 1005 36000 38708 28500 09/06/2005 2:32 PM 1109 1005 41800 44718 41500 09/06/2005 2:36 PM 1109 1005 20000 22018 19800 09/06/2005 2:46 PM 1109 1005 41500 44407 38400 09/07/2005 1:33 PM 1109 1005 18500 20441 18700 09/06/2005 2:49 PM 1109 1005 20400 22438 19100 09/06/2005 2:53 PM 1109 1005 38000 40782 36000 09/07/2005 1:30 PM 1109 1005 20200 22228 18600 09/07/2005 11:22 AM 1109 1005 19700 21703 18200 09/07/2005 11:16 AM 1109 1005 19100 21072 17600 09/07/2005 11:20 AM 1109 1005 16900 18755 16700 09/07/2005 11:18 AM 1109 1005 39300 42129 33300 09/07/2005 1:39 PM 1109 1005 27700 30075 27500 09/07/2005 1:42 PM 1109 1005 Survey Unit 9527-0003 Backgound (cpm)

Action Level (cpm)

Results (cpm)

Sample Name 9527-03-SL-00-01-0 9527-03-SL-00-02-0 9527-03-SL-00-03-0 9527-03-SL-00-04-0 9527-03-SL-00-10-0 9527-03-SL-00-11-0 9527-03-SL-00-12-0 9527-03-SL-00-05-0 9527-03-SL-00-06-0 9527-03-SL-00-07-0 9527-03-SL-00-08-0 Survey Release Record Scan Area Results 9527-03-SL-00-17-0 Above AL 9527-03-SL-00-13-0 9527-03-SL-00-14-0 9527-03-SL-00-15-0 9527-03-SL-00-16-0 9527-03-SL-00-09-0 AL - Action Level

9527-0003 SCAN AREAS 1 THROUGH 8 Log Date Log Time E600 S/N Probe S/N 14700 16430 14700 09/07/2005 8:25 AM 1105 1006 14600 16324 15100 09/07/2005 8:27 AM 1105 1006 14200 15901 14700 09/07/2005 8:29 AM 1105 1006 14600 16324 14800 09/07/2005 8:31 AM 1105 1006 14200 15901 15400 09/07/2005 8:36 AM 1105 1006 15200 16960 15800 09/07/2005 8:38 AM 1105 1006 15600 17383 15900 09/07/2005 8:39 AM 1105 1006 16200 18016 16200 09/07/2005 8:41 AM 1105 1006 16200 18016 15800 09/07/2005 8:42 AM 1105 1006 15200 16960 14400 09/07/2005 8:44 AM 1105 1006 15100 16854 15600 09/07/2005 8:46 AM 1105 1006 15000 16748 16100 09/07/2005 8:48 AM 1105 1006 15500 17277 15200 09/07/2005 8:51 AM 1105 1006 15200 16960 16400 09/07/2005 8:53 AM 1105 1006 14700 16430 15800 09/07/2005 8:55 AM 1105 1006 17200 19072 15500 09/07/2005 8:57 AM 1105 1006 18100 20020 15100 09/07/2005 8:58 AM 1105 1006 16200 18016 17300 09/07/2005 9:01 AM 1105 1006 19900 21913 16200 09/07/2005 9:02 AM 1105 1006 16400 18228 17000 09/07/2005 9:04 AM 1105 1006 19000 20967 15600 09/07/2005 10:35 AM 1105 1006 16800 18650 17200 09/07/2005 10:38 AM 1105 1006 19300 21283 16600 09/07/2005 10:40 AM 1105 1006 15300 17065 16600 09/07/2005 10:42 AM 1105 1006 18900 20862 14400 09/07/2005 10:47 AM 1105 1006 17500 19388 16400 09/07/2005 10:48 AM 1105 1006 16500 18333 15900 09/07/2005 10:50 AM 1105 1006 17100 18966 18500 09/07/2005 10:51 AM 1105 1006 18100 20020 15900 09/07/2005 10:53 AM 1105 1006 18100 20020 19000 09/07/2005 10:54 AM 1105 1006 17900 19809 16700 09/07/2005 11:05 AM 1105 1006 18900 20862 17400 09/07/2005 11:06 AM 1105 1006 19600 21598 17300 09/07/2005 11:08 AM 1105 1006 Survey Unit 9527-0003 Backgound (cpm)

Action Level (cpm)

Results (cpm)

Sample Name 9527-03-SC-01-01-0 9527-03-SC-01-02-0 9527-03-SC-01-03-0 9527-03-SC-01-04-0 9527-03-SC-01-05-0 9527-03-SC-01-06-0 9527-03-SC-01-07-0 9527-03-SC-01-08-0 9527-03-SC-01-09-0 9527-03-SC-01-10-0 9527-03-SC-01-11-0 9527-03-SC-01-12-0 9527-03-SC-01-13-0 9527-03-SC-01-14-0 9527-03-SC-01-15-0 9527-03-SC-01-16-0 9527-03-SC-01-17-0 9527-03-SC-01-18-0 9527-03-SC-01-19-0 9527-03-SC-01-20-0 9527-03-SC-01-21-0 9527-03-SC-01-22-0 9527-03-SC-01-23-0 9527-03-SC-01-24-0 9527-03-SC-01-25-0 9527-03-SC-01-26-0 9527-03-SC-01-27-0 9527-03-SC-01-28-0 9527-03-SC-01-29-0 9527-03-SC-01-30-0 9527-03-SC-01-31-0 9527-03-SC-01-32-0 9527-03-SC-01-33-0 Survey Release Record Scan Area Results Above AL AL - Action Level

9527-0003 SCAN AREAS 1 THROUGH 8 Log Date Log Time E600 S/N Probe S/N Survey Unit 9527-0003 Backgound (cpm)

Action Level (cpm)

Results (cpm)

Sample Name Survey Release Record Scan Area Results Above AL 17500 19388 18800 09/07/2005 11:10 AM 1105 1006 20500 22543 18400 09/07/2005 11:11 AM 1105 1006 18900 20862 19200 09/07/2005 11:13 AM 1105 1006 21100 23173 18500 09/07/2005 11:15 AM 1105 1006 19800 21808 19600 09/07/2005 11:16 AM 1105 1006 20900 22963 20500 09/07/2005 11:19 AM 1105 1006 20700 22753 20000 09/07/2005 11:21 AM 1105 1006 16600 18439 16400 09/07/2005 1:28 PM 1105 1006 18800 20757 18100 09/07/2005 1:30 PM 1105 1006 18300 20231 17200 09/07/2005 1:32 PM 1105 1006 16900 18755 17200 09/07/2005 1:38 PM 1105 1006 20100 22123 16200 09/07/2005 1:39 PM 1105 1006 18600 20546 17300 09/07/2005 1:41 PM 1105 1006 21600 23697 17800 09/07/2005 1:43 PM 1105 1006 17300 19177 18900 09/07/2005 1:45 PM 1105 1006 20900 22963 18200 09/07/2005 1:46 PM 1105 1006 21600 23697 20500 09/07/2005 1:48 PM 1105 1006 23600 25792 17800 09/07/2005 1:55 PM 1105 1006 25100 27361 18000 09/07/2005 1:57 PM 1105 1006 27200 29554 17500 09/07/2005 1:59 PM 1105 1006 24700 26943 17500 09/07/2005 2:00 PM 1105 1006 26900 29241 18400 09/07/2005 2:03 PM 1105 1006 28100 30492 19300 09/07/2005 2:04 PM 1105 1006 27900 30284 19500 09/07/2005 2:07 PM 1105 1006 25600 27883 19400 09/07/2005 2:10 PM 1105 1006 26700 29032 17200 09/07/2005 2:12 PM 1105 1006 27100 29449 19800 09/07/2005 2:14 PM 1105 1006 23200 25374 23500 09/07/2005 2:37 PM 1105 1006 25200 27466 20000 09/07/2005 2:39 PM 1105 1006 22700 24850 22100 09/07/2005 2:41 PM 1105 1006 25200 27466 22300 09/07/2005 2:42 PM 1105 1006 24100 26316 21700 09/07/2005 2:44 PM 1105 1006 25600 27883 20000 09/07/2005 2:45 PM 1105 1006 9527-03-SC-01-34-0 9527-03-SC-01-35-0 9527-03-SC-01-36-0 9527-03-SC-01-37-0 9527-03-SC-01-38-0 9527-03-SC-01-39-0 9527-03-SC-01-40-0 9527-03-SC-01-41-0 9527-03-SC-01-42-0 9527-03-SC-01-43-0 9527-03-SC-01-44-0 9527-03-SC-01-45-0 9527-03-SC-01-46-0 9527-03-SC-01-47-0 9527-03-SC-01-48-0 9527-03-SC-01-49-0 9527-03-SC-01-50-0 9527-03-SC-01-51-0 9527-03-SC-01-52-0 9527-03-SC-01-53-0 9527-03-SC-01-54-0 9527-03-SC-01-55-0 9527-03-SC-01-56-0 9527-03-SC-01-57-0 9527-03-SC-01-58-0 9527-03-SC-01-59-0 9527-03-SC-01-60-0 9527-03-SC-01-61-0 9527-03-SC-01-62-0 9527-03-SC-01-63-0 9527-03-SC-01-64-0 9527-03-SC-01-65-0 9527-03-SC-01-66-0 AL - Action Level

9527-0003 SCAN AREAS 1 THROUGH 8 Log Date Log Time E600 S/N Probe S/N Survey Unit 9527-0003 Backgound (cpm)

Action Level (cpm)

Results (cpm)

Sample Name Survey Release Record Scan Area Results Above AL 22400 24536 21400 09/07/2005 2:47 PM 1105 1006 26400 28719 21100 09/07/2005 2:47 PM 1105 1006 22400 24536 22500 09/07/2005 2:49 PM 1105 1006 29400 31847 19100 09/07/2005 2:50 PM 1105 1006 31100 33617 21500 09/07/2005 2:52 PM 1105 1006 30500 32992 21200 09/07/2005 2:53 PM 1105 1006 29100 31535 21300 09/07/2005 2:55 PM 1105 1006 23600 25792 20100 09/07/2005 2:57 PM 1105 1006 32200 34761 20700 09/07/2005 2:58 PM 1105 1006 27900 30284 21600 09/07/2005 2:59 PM 1105 1006 28900 31326 20400 09/07/2005 3:01 PM 1105 1006 29800 32264 19000 09/07/2005 3:02 PM 1105 1006 26600 28928 18800 09/07/2005 3:03 PM 1105 1006 35000 37670 19800 09/07/2005 3:05 PM 1105 1006 9527-03-SC-01-67-0 9527-03-SC-01-68-0 9527-03-SC-01-69-0 9527-03-SC-01-70-0 9527-03-SC-01-71-0 9527-03-SC-01-72-0 9527-03-SC-01-73-0 9527-03-SC-01-74-0 9527-03-SC-01-75-0 9527-03-SC-01-76-0 9527-03-SC-01-77-0 9527-03-SC-01-78-0 9527-03-SC-01-79-0 9527-03-SC-01-80-0 AL - Action Level

9527-0003 SCAN AREA 9 THROUGH 16 Log Date Log Time E600 S/N Probe S/N 41800 44718 26700 09/08/2005 8:48 AM 1105 1006 34700 37358 27900 09/08/2005 8:50 AM 1105 1006 33800 36424 27800 09/08/2005 8:53 AM 1105 1006 37800 40575 29200 09/08/2005 8:55 AM 1105 1006 37300 40056 33300 09/08/2005 8:57 AM 1105 1006 38500 41300 29600 09/08/2005 9:00 AM 1105 1006 38300 41093 30800 09/08/2005 9:02 AM 1105 1006 38500 41300 38000 09/08/2005 9:05 AM 1105 1006 39500 42336 32600 09/08/2005 9:09 AM 1105 1006 45400 48441 37200 09/08/2005 9:13 AM 1105 1006 50500 53707 36500 09/08/2005 9:17 AM 1105 1006 48400 51540 32900 09/08/2005 9:21 AM 1105 1006 52800 56079 34200 09/08/2005 9:24 AM 1105 1006 49500 52675 42300 09/08/2005 9:29 AM 1105 1006 51500 54739 43100 09/08/2005 9:32 AM 1105 1006 09/09/2005 10:32 AM 1105 1006 9527-03-ER-02-15-1 51500 54739 54100 09/08/2005 1:26 PM 1105 1006 52700 55976 33100 09/08/2005 9:36 AM 1105 1006 51700 54945 37800 09/08/2005 9:38 AM 1105 1006 53900 57213 40900 09/08/2005 9:42 AM 1105 1006 52900 56182 41000 09/08/2005 9:47 AM 1105 1006 52500 55770 42300 09/08/2005 9:50 AM 1105 1006 19000 20967 18200 09/08/2005 10:06 AM 1105 1006 17700 19599 18700 09/08/2005 10:09 AM 1105 1006 18500 20441 18100 09/08/2005 10:11 AM 1105 1006 18900 20862 19500 09/08/2005 10:13 AM 1105 1006 19800 21808 17400 09/08/2005 10:15 AM 1105 1006 19400 21388 20300 09/08/2005 10:17 AM 1105 1006 20000 22018 19500 09/08/2005 10:19 AM 1105 1006 19700 21703 21300 09/08/2005 10:21 AM 1105 1006 19500 21493 18200 09/08/2005 10:25 AM 1105 1006 20100 22123 20300 09/08/2005 10:28 AM 1105 1006 19900 21913 18300 09/08/2005 10:44 AM 1105 1006 18800 20757 18400 09/08/2005 10:46 AM 1105 1006 Survey Unit 9527-0003 Backgound (cpm)

Action Level (cpm)

Results (cpm)

Sample Name 9527-03-SC-02-01-0 9527-03-SC-02-02-0 9527-03-SC-02-03-0 9527-03-SC-02-04-0 9527-03-SC-02-05-0 9527-03-SC-02-06-0 9527-03-SC-02-07-0 9527-03-SC-02-08-0 9527-03-SC-02-09-0 9527-03-SC-02-10-0 9527-03-SC-02-11-0 9527-03-SC-02-12-0 9527-03-SC-02-13-0 9527-03-SC-02-14-0 9527-03-SC-02-15-0 9527-03-SC-02-16-0 9527-03-SC-02-17-0 9527-03-SC-02-18-0 9527-03-SC-02-19-0 9527-03-SC-02-20-0 9527-03-SC-02-21-0 9527-03-SC-02-22-0 9527-03-SC-02-23-0 9527-03-SC-02-24-0 9527-03-SC-02-25-0 9527-03-SC-02-26-0 9527-03-SC-02-27-0 9527-03-SC-02-28-0 9527-03-SC-02-29-0 9527-03-SC-02-30-0 9527-03-SC-02-31-0 9527-03-SC-02-32-0 Survey Release Record Scan Area Results Above AL AL - Action Level

9527-0003 SCAN AREA 9 THROUGH 16 Log Date Log Time E600 S/N Probe S/N Survey Unit 9527-0003 Backgound (cpm)

Action Level (cpm)

Results (cpm)

Sample Name Survey Release Record Scan Area Results Above AL 19100 21072 17600 09/08/2005 10:48 AM 1105 1006 19000 20967 19500 09/08/2005 10:50 AM 1105 1006 19500 21493 18900 09/08/2005 10:52 AM 1105 1006 18400 20336 19200 09/08/2005 10:53 AM 1105 1006 19000 20967 18300 09/08/2005 10:58 AM 1105 1006 18400 20336 18500 09/08/2005 10:59 AM 1105 1006 18100 20020 17300 09/08/2005 11:01 AM 1105 1006 17100 18966 18100 09/08/2005 11:03 AM 1105 1006 19600 21598 17000 09/08/2005 11:05 AM 1105 1006 18200 20125 18300 09/08/2005 11:06 AM 1105 1006 19000 20967 17500 09/08/2005 11:07 AM 1105 1006 19600 21598 17400 09/08/2005 11:08 AM 1105 1006 18600 20546 18300 09/08/2005 11:10 AM 1105 1006 18300 20231 18800 09/08/2005 11:12 AM 1105 1006 17900 19809 18700 09/08/2005 11:13 AM 1105 1006 19500 21493 19000 09/08/2005 11:14 AM 1105 1006 17000 18861 18000 09/08/2005 11:15 AM 1105 1006 18100 20020 18800 09/08/2005 11:17 AM 1105 1006 19000 20967 18900 09/08/2005 1:56 PM 1105 1006 18500 20441 20400 09/08/2005 1:57 PM 1105 1006 18600 20546 18400 09/08/2005 1:59 PM 1105 1006 18500 20441 17300 09/08/2005 2:00 PM 1105 1006 17700 19599 17600 09/08/2005 2:02 PM 1105 1006 18200 20125 17900 09/08/2005 2:03 PM 1105 1006 17900 19809 17100 09/08/2005 2:05 PM 1105 1006 18200 20125 18900 09/08/2005 2:06 PM 1105 1006 18400 20336 17700 09/08/2005 2:07 PM 1105 1006 18200 20125 18800 09/08/2005 2:10 PM 1105 1006 26600 28928 19000 09/08/2005 2:13 PM 1105 1006 24800 27047 18000 09/08/2005 2:14 PM 1105 1006 26000 28301 17400 09/08/2005 2:16 PM 1105 1006 26600 28928 17800 09/08/2005 2:18 PM 1105 1006 27000 29345 18400 09/08/2005 2:19 PM 1105 1006 9527-03-SC-02-33-0 9527-03-SC-02-34-0 9527-03-SC-02-35-0 9527-03-SC-02-36-0 9527-03-SC-02-37-0 9527-03-SC-02-38-0 9527-03-SC-02-39-0 9527-03-SC-02-40-0 9527-03-SC-02-41-0 9527-03-SC-02-42-0 9527-03-SC-02-43-0 9527-03-SC-02-44-0 9527-03-SC-02-45-0 9527-03-SC-02-46-0 9527-03-SC-02-47-0 9527-03-SC-02-48-0 9527-03-SC-02-49-0 9527-03-SC-02-50-0 9527-03-SC-02-51-0 9527-03-SC-02-52-0 9527-03-SC-02-53-0 9527-03-SC-02-54-0 9527-03-SC-02-55-0 9527-03-SC-02-56-0 9527-03-SC-02-57-0 9527-03-SC-02-58-0 9527-03-SC-02-59-0 9527-03-SC-02-60-0 9527-03-SC-02-61-0 9527-03-SC-02-62-0 9527-03-SC-02-63-0 9527-03-SC-02-64-0 9527-03-SC-02-65-0 AL - Action Level

9527-0003 SCAN AREA 9 THROUGH 16 Log Date Log Time E600 S/N Probe S/N Survey Unit 9527-0003 Backgound (cpm)

Action Level (cpm)

Results (cpm)

Sample Name Survey Release Record Scan Area Results Above AL 29100 31535 17300 09/08/2005 2:21 PM 1105 1006 26000 28301 19200 09/08/2005 2:23 PM 1105 1006 27700 30075 17700 09/08/2005 2:25 PM 1105 1006 25900 28197 15800 09/08/2005 2:26 PM 1105 1006 27400 29762 18800 09/08/2005 2:28 PM 1105 1006 18300 20231 18200 09/08/2005 2:41 PM 1105 1006 17700 19599 17000 09/08/2005 2:43 PM 1105 1006 19500 21493 16300 09/08/2005 2:45 PM 1105 1006 17800 19704 17500 09/08/2005 2:46 PM 1105 1006 18400 20336 15900 09/08/2005 2:47 PM 1105 1006 17900 19809 17400 09/08/2005 2:50 PM 1105 1006 18900 20862 15600 09/08/2005 2:52 PM 1105 1006 15000 16748 15100 09/08/2005 2:54 PM 1105 1006 16400 18228 14900 09/08/2005 2:56 PM 1105 1006 15400 17171 16600 09/08/2005 2:59 PM 1105 1006 9527-03-SC-02-66-0 9527-03-SC-02-67-0 9527-03-SC-02-68-0 9527-03-SC-02-69-0 9527-03-SC-02-70-0 9527-03-SC-02-71-0 9527-03-SC-02-72-0 9527-03-SC-02-73-0 9527-03-SC-02-74-0 9527-03-SC-02-75-0 9527-03-SC-02-76-0 9527-03-SC-02-77-0 9527-03-SC-02-78-0 9527-03-SC-02-79-0 9527-03-SC-02-80-0 AL - Action Level

9527-0003 SCAN AREAS 17 THROUGH 22 Log Date Log Time E600 S/N Probe S/N 16000 17805 15200 09/08/2005 3:01 PM 1105 1006 16500 18333 13000 09/08/2005 3:03 PM 1105 1006 16600 18439 14900 09/08/2005 3:04 PM 1105 1006 15600 17383 16800 09/08/2005 3:05 PM 1105 1006 14600 16324 14800 09/08/2005 3:08 PM 1105 1006 15900 17700 14300 09/08/2005 3:09 PM 1105 1006 15000 16748 15800 09/08/2005 3:10 PM 1105 1006 14000 15689 15300 09/08/2005 3:12 PM 1105 1006 17800 19704 15600 09/08/2005 3:14 PM 1105 1006 13200 14840 14900

+

09/08/2005 3:16 PM 1105 1006 15500 17277 16300 09/09/2005 8:13 AM 1105 1006 15800 17594 15200 09/09/2005 8:15 AM 1105 1006 16500 18333 15600 09/09/2005 8:18 AM 1105 1006 16500 18333 16500 09/09/2005 8:20 AM 1105 1006 14700 16430 15500 09/09/2005 8:22 AM 1105 1006 16000 17805 15200 09/09/2005 8:24 AM 1105 1006 16300 18122 16500 09/09/2005 8:26 AM 1105 1006 16300 18122 14100 09/09/2005 8:28 AM 1105 1006 15000 16748 16000 09/09/2005 8:31 AM 1105 1006 17000 18861 14900 09/09/2005 8:32 AM 1105 1006 18800 20757 18000 09/09/2005 8:37 AM 1105 1006 18000 19915 16400 09/09/2005 8:38 AM 1105 1006 17500 19388 15800 09/09/2005 8:40 AM 1105 1006 18600 20546 16200 09/09/2005 8:42 AM 1105 1006 18400 20336 16900 09/09/2005 8:44 AM 1105 1006 18900 20862 16100 09/09/2005 8:46 AM 1105 1006 17800 19704 16200 09/09/2005 8:48 AM 1105 1006 17400 19283 15200 09/09/2005 8:50 AM 1105 1006 17800 19704 15900 09/09/2005 8:53 AM 1105 1006 18100 20020 18100 09/09/2005 8:54 AM 1105 1006 25100 27361 18800 09/09/2005 9:39 AM 1105 1006 24400 26629 17600 09/09/2005 9:40 AM 1105 1006 21600 23697 18100 09/09/2005 9:42 AM 1105 1006 Survey Release Record Scan Area Results Above AL 9527-03-SC-03-32-0 9527-03-SC-03-33-0 9527-03-SC-03-28-0 9527-03-SC-03-29-0 9527-03-SC-03-30-0 9527-03-SC-03-31-0 9527-03-SC-03-24-0 9527-03-SC-03-25-0 9527-03-SC-03-26-0 9527-03-SC-03-27-0 9527-03-SC-03-20-0 9527-03-SC-03-21-0 9527-03-SC-03-22-0 9527-03-SC-03-23-0 9527-03-SC-03-16-0 9527-03-SC-03-17-0 9527-03-SC-03-18-0 9527-03-SC-03-19-0 9527-03-SC-03-14-0 9527-03-SC-03-15-0 9527-03-SC-03-10-0 9527-03-SC-03-11-0 9527-03-SC-03-12-0 9527-03-SC-03-13-0 9527-03-SC-03-06-0 9527-03-SC-03-07-0 9527-03-SC-03-08-0 9527-03-SC-03-09-0 9527-03-SC-03-02-0 9527-03-SC-03-03-0 9527-03-SC-03-04-0 9527-03-SC-03-05-0 9527-03-SC-03-01-0 Survey Unit 9527-0003 Backgound (cpm)

Action Level (cpm)

Results (cpm)

Sample Name AL - Action Level

9527-0003 SCAN AREAS 17 THROUGH 22 Log Date Log Time E600 S/N Probe S/N Survey Release Record Scan Area Results Above AL Survey Unit 9527-0003 Backgound (cpm)

Action Level (cpm)

Results (cpm)

Sample Name 22600 24745 18900 09/09/2005 9:43 AM 1105 1006 25100 27361 16900 09/09/2005 9:45 AM 1105 1006 24300 26525 18000 09/09/2005 9:47 AM 1105 1006 24000 26211 20100 09/09/2005 9:48 AM 1105 1006 20000 22018 17400 09/09/2005 9:50 AM 1105 1006 24900 27152 17200 09/09/2005 9:52 AM 1105 1006 23300 25478 15700 09/09/2005 9:54 AM 1105 1006 26300 28614 19600 09/09/2005 9:56 AM 1105 1006 26600 28928 20000 09/09/2005 9:58 AM 1105 1006 29400 31847 19400 09/09/2005 10:00 AM 1105 1006 31300 33825 19200 09/09/2005 10:02 AM 1105 1006 31500 34033 19200 09/09/2005 10:04 AM 1105 1006 29200 31639 21100 09/09/2005 10:07 AM 1105 1006 30500 32992 18400 09/09/2005 10:08 AM 1105 1006 32200 34761 18500 09/09/2005 10:10 AM 1105 1006 30700 33201 20000 09/09/2005 10:11 AM 1105 1006 31800 34345 20200 09/09/2005 10:13 AM 1105 1006 39700 42544 35500 09/09/2005 10:53 AM 1105 1006 35100 37774 34400 09/09/2005 10:55 AM 1105 1006 39500 42336 28600 09/09/2005 10:57 AM 1105 1006 37300 40056 29400 09/09/2005 11:00 AM 1105 1006 36400 39123 35400 09/09/2005 11:02 AM 1105 1006 34900 37566 26800 09/09/2005 11:04 AM 1105 1006 33800 36424 32000 09/09/2005 11:07 AM 1105 1006 31200 33721 28500 09/09/2005 11:09 AM 1105 1006 32600 35177 25800 09/09/2005 11:11 AM 1105 1006 32800 35385 24700 09/09/2005 11:13 AM 1105 1006 9527-03-SC-03-58-0 9527-03-SC-03-59-0 9527-03-SC-03-60-0 9527-03-SC-03-54-0 9527-03-SC-03-55-0 9527-03-SC-03-56-0 9527-03-SC-03-57-0 9527-03-SC-03-50-0 9527-03-SC-03-51-0 9527-03-SC-03-52-0 9527-03-SC-03-53-0 9527-03-SC-03-46-0 9527-03-SC-03-47-0 9527-03-SC-03-48-0 9527-03-SC-03-49-0 9527-03-SC-03-44-0 9527-03-SC-03-45-0 9527-03-SC-03-40-0 9527-03-SC-03-41-0 9527-03-SC-03-42-0 9527-03-SC-03-43-0 9527-03-SC-03-36-0 9527-03-SC-03-37-0 9527-03-SC-03-38-0 9527-03-SC-03-39-0 9527-03-SC-03-34-0 9527-03-SC-03-35-0 AL - Action Level

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0003 RELEASE RECORD c Split Sample Assessment Forms (2 Pages)

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0003 RELEASE RECORD d Preliminary Data Forms (2 Pages)

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0003 RELEASE RECORD e Graphical Representation of Data (4 Pages)

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0003 RELEASE RECORD f Sign Test Calculation (1 Page)

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0003 RELEASE RECORD g COMPASS DQA Surface Soil Report with Retrospective Power Curve (4 Pages)