JAFP-06-0164, JAFNPP - Site Audit Request - Oct 2006 SPDES Discharge Monitoring Report

From kanterella
(Redirected from ML063630304)
Jump to navigation Jump to search
JAFNPP - Site Audit Request - Oct 2006 SPDES Discharge Monitoring Report
ML063630304
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 11/21/2006
From: Peter Dietrich
Entergy Nuclear Northeast, Entergy Nuclear Operations
To:
Office of Nuclear Reactor Regulation, State of NY, Dept of Environmental Conservation
jmm7
References
JAFP-06-0164
Download: ML063630304 (21)


Text

Entergy Nuclear Northeast Entergy Nuclear Operations, Inc.

James A. Fitzpatrick NPP Enter--- P.O. Box 110 Lycoming, NY 13093 Tel 315 349 6024 Fax 315 349 6480 November 21, 2006 Pete Dietrich Site Vice President - JAF

.JAFP-06-0164 New York State Department Of Environmental Conservation B3ureau of Watershed Compliance Programs 625 Broadway 4th Floor Albany, NY 12233-3506

SUBJECT:

JAMES A. FITZPATRICK NUCLEAR POWER PLANT SPDES REPORT FACILITY ID #NY0020109 Gentlemen:

Attached is the James A. FitzPatrick Nuclear Power Plant State Pollutant Discharge Elimination System Discharge Monitoring Report (DMR) for the month of October 2006.

If you have any questions, please contact Mr. Michael Rodgers, P.E. of the plant staff at 315-349-6571.

.DIE SITE VICE P IDENT - JA PD/Mjbh Attachments:

1) NOTES
2) Wastewater Facility Operations Report
3) Discharge Monitoring Report (DMR)

Xc: Gillette, F. (NYSDEC-Region 7)w/att Oswego Co. Dept of Health (OCDOH)w/att Nutter, V. (WPO)w/att RMS (JAF)w/att Buckley, R. (M-ECH-30)w/att

ENTERGY NUCLEAR OPERATIONS, INC.

JAMES A. FITZPATRICK NUCLEAR POWER PLANT MONTH OF OCTOBER 2006 SPDES REPORT

- NOTES --

SPO~rS NY0020109

1. In agreement with the Region 7 Water Engineer, a DMR for sanitary wastes (discharge number 012-A) and an appropriate monthly Wastewater Facility Operation Report Is being submitted In lieu of Form 92-15-7.
2. In accordance with section 5.13 of the 1999 NELAC Manual the following SPDES analyses are subcontracted as follows:

0 O'Brien & Gore Laboratories, Inc. (Lab ID# NY 00034): Oil and Grease (00556) 0 Life Science Laboratories, Inc. (Lab ID# NY 01042): Sewage Treatment Plant Effluent:

- Biological Oxygen Demand (BOD-5) (00310)

- Total Suspended Solids (00530)

- Fecal Coliform (74055)

92-15-7 (7/91)-27c NEW YORK STATE DEPARTMENT OF ENVIROMENTAL CONSERVATION WAaTEWATER FACILITY OPERATION REPORT FOR TWP UflMTSJ DIVISION OF WATER Page I at I f'l /*,k *,AEB

  • AA*

SWEASET PiEIPERIT No. NY--0020Ja JaEsWATE FACIL17Y NPEAMEO FACILUlY NAM REOR FOR T---- MONTH. OF Ot b~er 200 Fitzpatrick Wastewater Treatment Plant Entergy Nuclear FACILITY OWNER FftzpatrickLLC Fw=bm~&(312-24&1=0) 268 LakeFACILrrV LOCATION NY 13093 Road Lycoming, VOLUME OF WASWATER TEMPERATURE (oC.) pH (S.U) Sids ____B.O.D.s (mg/i) Effluent Flow No. Flow Avg Influent Effluent Influent Date Effluent Effluent SS Effluent TSS Influent Effluent Fecal Coliform MGD MGD Grab Grab Grab CL2 Grab Grab MI/L Grab Mg/L Grab Grab Col/100 ml Mg/L avg 1 Sun I 00 - 1_ U_ 7T" 77-2 Mon 0.- 0.4_-"

-8. - 7.3 <0 1.3 4

3 TUG Wed 0.01_j____.

T77___

a Thiu-r 9.7 1__ 7.1 <0.0.

2 . -- -- T i 33.0 6 Fri- 0.013 - - - /-< ---

1.~3 7 sat 8.7--6.< 1--" -*

a Sun 18.7 T.9 .1 0.__

9 Men 0__00___18.5 -7.0 <0T -0.5____

-. -- F - 7.1_

10 Tuee 'T _

-.- -9.

11 Wed 0.1

-51.

-T -.

12 Thur -T-u

- .u . -~w 113 -I .... I'*J 7"*n nR 14 1 Sat U.I.W 0013 0.

1M X ULU ir* J 1.0

  • q I-.- -

15 016 82.

1M I 71.

Sun 81. 7.2 16 1]4 Mon 0 IIr *J=l 17 Tue f48172 I

<0.

5.0 3 o.3 18 Wed _ 0.0_ 17 -18.8 7.3 1~ - _ _

19 - Thur 0.01__77 20 Fri__ -~-UX-

-9. 7.

21 Sat (T.07r- -827.-

22 Sun 2 -.

1- __

-. 7.

23 Men 1_0.009 T7.6 1]0-_

24 Tug .'t - _

__ _ _ ____ _ 7.4 - 7.3 -

25 1Wed -- ni 26 r 1 u.UI5 1/?

~1I ~J., 73 . <0.

Z_ 1292010 0.01--:~3-- 1 I Z 7"4 27 28 I 1 1 72-- -1 -3 0 1- - -7.-

16.8 29 U.U- - -

cOT T- -.-

30 I. 7F 1

- 1TE4'.'-S" lt*.3 7.2 1----___

.5 *I *.~

Minimum Minimum Minimum Minimum Total 0.222 0.0 16.3 0.0 6.6 Maximum Maximum Maximum Maximum Maxdmum Maximum SPDES SPDES SPDES Maximum 0.025 0.0 7.4 0.1 3 /v <4 30.0 1.6

___- IF 197 . 7.4 0.1 130d/avg Average -.

0.0072

~ I &

i Vim 1829 .

<0 1.

4f9 71 I 0 Signature: 4 4 ( Date: 11/01/2006

NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) r-wma-sm~md DISCHARGE MONITORING REPORT (DMR)"

'ERM rTfEE NAMEIADDRESS PIwikW&FadIlyNawJLoomrkJ iDolffawit) Page I lAME: ENTERGY NUCLEAR FITZPATRICK DUR MALILG ZIP CODE: 13093 U)RESS: 268 LAKE ROAD EAST MAJOR PERMIT NUMBER DISCARGE NUMBER LYCOMING, NY ¶3093 (SUBR07)

ACIUTY: ENTERGY NUCLEAR FITZPATRICK MONITORING PERIOD CLARIFIER SLOWDOWN

.OCATION: 268 LAKE ROAD EAST IYEARI I DO IIEAI Mo I DAY AYI Extenmal Oullal LYCOMING, NY 13093

'rTTN:T A SULLIVAN FROM I Lo TO  ! No Dam kdaoirt["-

)WIENMh AND EJIPLANAnON OF ANY VIOLATIONS (R~kMf~ AN ullaetuasu hwe)

4. Penn 3mo-1 (Fev.wAM Pmwbm eituon may be used

NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) FOMAWA DISCHARGE MONITORING REPORT (OUR) *0 Na 20i4OOX~

ERMII"EE NAMEIADDRESS Plnwg FadlyAWmeLoiatk Un#DX/ Pap 2 lAME: ENTERGY NUCLEAR FITZPATRICK OMR UAILG MP CODE: 13093 QDDRESS: 268 LAKE ROAD EAST NYO=109 0MI MAJOR LYGOMING, NY '13093 (SUBRO')

'ACILITY: ENTERGY NUCLEAR FITZPATRICK OILNJATER SEPARATOR MONITORING PERIOD

.OCATION: 268 LAKE ROAD EAST Exdnmal Ou"i LYCOMING, NY 13093 YVEAM MO SDAY ,- IVMEJARI MO IDAYI FROM j06 '10 01 TOW 0 3 No ." uImiir[]

k'T'N:T A SULLIVAN QUAUTY OR CONCENTRATION NO. aTY PARAMETER ., QUANTITY OR LOADING VALUE VALUE UNITS VALUE VALUE ULion SAMPLE MEASUREMENT

-ffmuntGross REQUIREMENT :0 *  : _,_ .___N_ -U ids, total un~ap~d SAMPLE MEASUREMENT 05301 0PERMT 41 77y~

  • iffluent Grou REUIEMN MI ________ - -W'J*Ai.s v.gi ___$

SAMPLE

)I &gnmu MEASUREMENT 0556 1 0 PERMIT VV.X ....-

ffiiuent Gmos REQUIREMENT ~ ~ _______ ______ ______ g NAME.TITLE PR..WAL EJC.IEVE*FiFICER DATETELEPHO SITE/VITCE PRENSIPAD.*C'IEN OFFICERfftpww *,*,*,*,,,,,I-,*p&RVTW,*--Cron ad,=--,-,,, . F TELPJO .

P. DIETRICH ft WAWA"..

TYD OR PRIEDK T mo DAY

)MMETU AND EPLANATION OF ANY VIOLATIO* (Asdins all asldmmfit two)

I ADOITONAL GRAS SAMPLE SHALL BEWAKEN DURNG ANY DISCHARGE FROM THE FLY ASH HOPPEFL A Form NMI-lRQv.O1O1M Previnuk odflnne -.-

NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

FaiA-S DISCHARGE MONITORING REPORT (DMR) OW mmaO4&C4W

,ERMFrTEE NAME/AWDORESS 0Mdah FaWMlm4.nCkm n1tmw' U

Page 3 lAME:

WDORESS:

ENTERGY NUCLEAR FITZPATRICK 298 LAKE ROAD EAST I N0Ez9 c r Da MAILING ZIP CODE: 13093 LYCOMING, NY 13095 Ij PERMINUBER I ISHAGEg NUMBlfERI MAJOR

'ACILITY: ENTERGY NUCLEAR FITZPATRICK (SUBROT)

MONITORING PERIOD OCATION: 268 LAKE ROAD EAST i SEDIMENT CONTAINMENT POND LYCOMING, NY 13093 YEAR I[ DAY I IYEARI MO DAY Exarns OuiDa tT1N:T A SULWVAN FROM1 1 10 1o' TO E06_ 10 31 1 N. Dat hliilatoC)-'

AOQUNTIIj OR LOADING PARAMETER QUALITY OR CONCENTRATION OF ANKm TYPE t: 43 VALUE VALUE UNITS VALUE VALUE VALUE UNITS low not * -ME ASUREMEN%,T SAMPLE 18000aONCEl 18000 gal/d ...

DOSS IN 0 0 IRATCH rALTD PERMIT  : i .sr',..rr Rowed Increase, REURMN

  • L SA12 ..... ~,.d W t r .. .

Ads. total suspended >~

ONCE/

)530 IN 0 PERMIT 4AMPLE 47.7 mg/L

. . .0. *fl 0 AI lowed Incrl_*ease REQUIREMENT +*,<,s*-

  • % e..4c3&4. .-

ata*l

..*M *. , .. EASAMPLE.

_SUREM ENT "" .. _ <O L _

)545 IN 0

<0-' 00 AT U rGR A AR PERMIT v9 lowed Incease REUIEMN 1fW

~ *~' ~ ~ m.~*

at&____

si.,

AM PRINCIPAL EXECUTIVE OFFICER

-ITLE mjS md iit US i .IAa m sE DIATE,

£TýEVIICE PRESIDENT Idm m~resW

  1. IkVICW, v kabk maa w -~uwa:5 aaisI m maMdh WAUai tgW 31m 342-3840 06 11 120 uiv rEeo TYPED OR IRf morm AND EXPULNATM A P O nnOlATo AoN v menmn. a2 mdaemvea hWrm) iere were five batch discharges from this outfall during this reporting period.

Form 3220-1 (eAwIM)l PinIom .Uaonu nwy be used

NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

OW NM 30404004 DISCHARGE MONITORING REPORT (DMR)

RMITrEE NAME/ADORESS (dutS Fadc1yNamnewLoam WwDW)rQ Page 4 kME: ENTERGY NUCLEAR FITZPATRICK DIM MAILMG ZIP CODE: 13093

)DRESS: 268 LAKE ROAD EAST MAJOR LYCOMING, NY 13093 (SUBR07)

LCIUTY: ENTERGY NUCLEAR FITZPATRICK ICATION: 288 LAKE ROAD EAST MONITORING PERIOD I SANITARY WASTES ExrnSal Outll A DAYMO DA V, YE MO I DAY Me Det hdlstlEO LYCOMING, NY 13093 PROM 06 110 01 TO [ 06 110 1 31 flN:T A SULLIVAN QUANTITY OR LOADING QUALITY OR CONCENTRATIONEX SAMPLE -

PARAMETER EX OF____ ANA_____ TYPE___

VALUE VALUE UNITS VALUE VALUE VALUE UNITS

-wrt SAMPLE 0 DAILY INSTAN SMEASUREMENT 25000 gal/d ...........

)0m51 0 fluent Gross PERMIT RE UIE EN..........~4~

.*4*; * ,,0000 ...  :.  : 4, 9 r:;

~ 4 A44~4454'$'

~w

r%

l

" " - SAMPLE ..... ONCE/

D, day 20 dg. C MEASURMEENT .... C4 <4 mg/L 0 QWT1 "AR

)31010 -

fluent Gross PERMIT "r . .**P:.f:*rE 49xt.W< . ' ,*">  : ."

_____________ .___REQUIREMENT 9 ~~ a[, Dow"s8w. th*V?~ n SAMPLE MEASUREMENT "--" 6.6 7.4 SU. 0 AILY ;GRAB 9400 10 PERMIT ... "4  :  :: 4 "9 ' 9'2 fluent Gross toa-upne

'ks REUIEMN SAMPLE... o*

, ~- ,~%I LaL. ,,4 CI ww_____

SSUPLEMNT -19.0 33.0 Mg/L 0 NTH--

I.-

c: T& 4 O. . *- j""4 9%:  :

Mw 10 PERMIT A 'i fluent Gross REQUIREMENTI"  ;:.: ::k:ýi: _ _ __ _ - .;:*:so: .:0

'--, Settie .SAMPLE MEASUREMENT "" "_ 0.1 mL/L 0 AILY GRAB

)54510 PERMIT *X X... ti .. .... . "

fluent Gross _'_

___________,_'_,__ RE..EM N

____________ _ _ _ _ _ _ _ _ ______ ____________  ! * -* . * . ' *: *.: .* , ; * *.:. ,;4 . -.. .4 4 9*.),"*;

.... ...4 REOIRME_ k -- -i -,11M4 hkrine, WWd rakdu* SAMPLE MEASUREMENT - __r . . . .4 . . .. . . 1.8 mg/L 0 . .AILY

. . ' . . . . GRAB 10601 0 PERMIT . §i::*.

' 4..',"'4"v .Pa"...

fluentGrossREQUI1REMENT x :s~o: ... ' tMnt

316form, feoad genead SAMPLE NCEI iMEASUREMENT "" 30 30 1/100] 0 ONRCE 10 5 1 0 P ER MIT , . *. ' / . i o.i, . - ...* ', . .f..

.'..t,.

fluent Gross REQUIREMENT 1I4O*44.WC 1199.4.Q nL ' yM z,,,-v,,

  • -..-'-**, .- "-*-' ,z=,':-w,,,- S- TELHO- DAT-

?4AMEFTITLE PRINCIPAL EXECUTIVE OFFICER DATE DIETRLICH ITE VICE PRESIDENT

,,..--u~ea pn ntan h, *,

s u,-b,,s.m,-*,.*"

teom aww X m sano ow-casAoE 315 342-3840 06 11 20 TY PED OR PRINTE A90r AMS "M umA NO DAY

)MMENTS AND EXPLANATMO OF ANT YCOLATINM (Rhlsmnc an utamctmnds harm)

A Form 3130-1 (RevAQIMfI PrewlOUs odID" umr-' """~%4h44W

NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

FOIMANA DISCHARGE MONITORING REPORT (DMR) 10 Nm 2040400 ERMITTEE NAM/ADORESS ,wAFadaytam9L AlN IDwzn Palp 5 lAME: ENTERGY NUCLEAR FITZPATRICK S NY002DI09 * .... 026A ODDRESS: 268 LAKE ROAD EAST PERMff~u. NUBR [ =01SCHARuEUMBER I DMR MALING ZIP CODE: 13093 LYCOMING, NY 13093 MAJOR

'ACIUTY: ENTERGY NUCLEAR FITZPATRICK (SUBR07)

OCATION: 268 LAKE ROAD EAST MONITORING PERIOD DIESEL GEN. OIL/WATER SEPARATE LYCOMING, NY 13093 IYEARI MO IDAY I EARI MO IDAYI External Oulall LTrN:T A SULLIVAN FROM 1 06 10 01 TO1 06 10 1 31 ND Data kmdIaata[j

....x:.4*4.r.;.:

QUANTITY OR LOADING NO. pm my SAMPLE QUALITY OR CONCENTRATION

.  : VALUE VALUE UNITS VALUE VALUE VALUE UNITS low rate SAMPLE MEASUREMENT 0056 1 0 PERMIT '

Ifluent Gross REQUIREMENT ...... - -- .

' , , ... jgalld . . ,.... . .. . ...

H HSAMPLE- MEASUREMENT 34o0 1 0 PERMIT <:r ***< *<<*

Ifluent Gross -  :..,.m .4**

REURMN - -

W4MM~81 SU4<y*<~i~IJy~

4 total Slid, SA- .usprhad MEASUREMENT -P 501 0 PERMIT ......... * . :

fluent Gross REUREMENT ~'~~<~ ~*-

a geaeSAMPLE ..

il& grease MEASUREMENT 5561 0 PERMIT 7 1 0*.....

fluent Gross REQUIREMENT L -:mL IAMEIMTE PIUNCPAL EXFGUTIVE OffiCER DAIN ITE VICE PRESIDENT = TU1NE1 CIPAL S.- arlO 315 342-3840: 06 11 20 TYPED OR PRINTE dNIAM OFACER OR AUm o WAMET AND EXPLIANATWO OF DNY VIOLATIONS OWssruOs aN mUnhastu~a haM)

Form, =20-1 (IsVAIMAS Preat esloetm" uu be Bm

NATIONAL POLWTANT DISCHARGE ELIMINATION SYSTEM (NPDES) ow w~ 804004 DISCHARGE MONITORING REPORT (OMR)

ERMITTEE NAMJEADORESS (knm9 Fa IAmiy cakn#UDJwermn Pgso 6 lAME: ENTERGY NUCLEAR FITZPATRICK N4Y002DIS 09 oMaL W IG ZI CODE: 13093 DORESS: 268 LAKE ROAD EAST MAJOR PERMIT NUMBER DISCHARGE NUMBERA LYCOMING, NY 13093 (SUBRO7)

ACIULTY: ENTERGY NUCLEAR FITZPATRICK OCATION: 268 LAKE ROAD EAST I MONITORING PDOA I ANTHRACITE FILTER BACKWASH Extoma Outid LYCOMING, NY 13093 YEAR i .o IDAYI IYEAI R MO DAY FROM 06 10 01 TO 0 10 31 No 0.8. b~kath{]

LTTN:T ASULLIVAN PA.R . TER QUANTITY OR LOADING QUALITY oR oNcENTRAION NSPE PARAME _____ EX OPAmfLtS Vm VALUE VALUE UNITS VALUE VALUE VALUE UNITS ids, total aupedd SAMPLE UNIS2.9 3.7 mg/L 0 EKLY GRAB 0530 20

___,_020 PERT .

-NPERMoTt_______________.________..____._______-

_________V_;Hr,;"fj

  • i*
    i*;
    :* -: **::* I.i:_ _ _*.;:::.:

i:~ _ _  :!:__.!::*i~*:'

_ .. * '::'" W-A L':;'::?*;* M.-  ::: * * * -. *:: .;i** .*

NAMEITITLE PRINCPAL EXECUTIVEi I

?. DIETRICIH 3ITE VICE PRESIDENT TYPED OR PWR=N MWENT AND EXPLANATION OF ANY VIOLATIONS (Rdmrncse .ll malfmsuont hwee)

FOFM =0-i (ROVAIM) PrOVIOUS 01OU"M M-1 hý

NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPOES)

DISCHARGE MONITORING REPORT (DMA) oo w~2040400 ERMITTEE NAME/ADORESS (kindw FmidjNanwdmLocal*Dm ILn#w P" 7 lAME: ENTERGY NUCLEAR FITZPATRICK PEI fNUMBER~og " IMAG NUMBE D)RESS: 268 LAKE ROAD EAST DMA MAILING ZIP CODE: 13M93 LYCOMING, NY 13093 MAJOR ACIUTY: ENTERGY NUCLEAR FITZPATRICK (SUBR07)

OCATION: 268 LAKE ROAD EAST MONITORING PERIOD WASTE NEUTRAUZATION TANK DIS.

LYCOMING, NY 13003 IYEAR MO DAY IYEAR MO I IDA Waml Ouft k*,'N:T A SULLIVAN FROM 06 10101 TO 06 10 31od No Dols lmdkmorQ PARAMETER *.*i;QUANTITY OR LOADING QUALITY OR CONCENTRATION SAMPE VALUE VALUE UNITS VALUE VALUE VALUE UNITS SAMPLE ..

MEASUREMENT ......... ONCE/

0400 IN 0 PERMIT -"

7.1 7.1 SU 0 kAq'*, PAR

,Jlowed Increase " "' " ,'" r" ' '

REQUIREMENT v.....................S olls, 10alsspende SAMPLE S ONCE!

0 .. __. .

DS IN0 MEASUEMENT ... 28.4 28.4 mg/L 01BATCH GB 050IN0PERMIT *e ~~ ~~ *. BATC 1, GRAB ilowed increase REQUIREMENT Iti k g4J'

_ _ _ _ _ *...., ~ - ~me Form =320-t (PVIMs.liS PrIimw euonh miy be used.

NATIONAL POLWTANT DISCHARGE ELIMINATION SYSTEM tNPDES) FarmApprun 0h ft 20404M"6 DISCHARGE MONITORING REPORT (DMR) iwn-rEE NAMEIADRESS 1kwhMbeFAdWyN.am&Lw~atkm Dfwt)"pa WME:

DORESS:

ENTERGY NUCLEAR FITZPATRICK 268 LAKE ROAD EAST II EMT N00210 jDSCAG UBR 001~EZ NME DUR MAILING ZIP CODE:

MAJOR 13093 LYCOMING, NY 13003 (SUBR07) kCILITY: ENTERGY NUCLEAR FITZPATRICK i LOW COND. WASTE SAMPLE TANK II .

MONITORING PERIOD

. . . . . II

)CATION: 268 LAKE ROAD EAST Exlema OuU TTN:T A SUWVAN LYGOMING, NY 13093 FROM 1 06 ,.10 To [ 06 lo J No Data kldluh.10qI!

~. :.OR LOADING

~: .~~'**~ O I~lMI~MFNO.~ aREQUeCy SAMPLE PARAMETER *. QUANTITY OR OUAITY 4WSLIII OR CONCENTRATION EX a.

OF ANALIS mALS YP TYPE S ,. VALUE VALUE UNITS VALUE VALUE VALUE UNITS acic SAMPLE MMoncURtana EA 'MENT ITT 0095 IN 0 PERMIT ,. ~ ~ I5 Jlowed Increase REQUIREMENT . .. _.__..___:____ ___....._....!__.-_-"_.... ..-

H AM PL E. .. . , .

MEASUREMENT 0400 IN 0 PERMIT ~

ilowod Increase REýiEMN I____

Y- -MA(II~~~~- SUM~C-H SAMPLE MEASUREMENT ..... .

0400 P0 PERMIT 0`ý'WRMI :4 I"-`' z z' '*,*"1'P'"

eComments REQUIREMENT ~~- ~II ~ ~ ~ "bs laids, total msupendd SAMPLE_.. ..

MEASUREMENT _____ ___________________________

0w3 IN0 PERMIT w "  : a* * * - ' -

&owed Increase REQUIREMENT . . -'- togA v" .p,.""

NAMEFT1TLE PRINCIPAL E)ECUTIVE O R TLPO DATE P. DIETRICH 315 342-3840 066112 11 20 SITE VICE PRESIDENT31 .roATRE+11I-I ddv mskim*V---"* -.r~OFRCER CUTW* OR . 34380 NSR J ODA TYPED OR PRINTED NCf m IMIN A OMMENTB AND EXPLANATION OF ANY viOLATIO (Reem a anl .uns he-m)

CONDUCTMIY ISEQUAL TO OR LESsTHAN IOUMHOSJCM. THEN THE PH UMITIS (4.0 - 9.0). MONITORING OFCONDUCTIVIY is RQuiTNOAP.O PH UMIT is EXCEEDED. ENTER NODI 9' INPLAGE OF EASUREMENTWHEN PARAMETER IS NOT REQUIRED FORENTIRE MONrrIORING PERIOD.

1A Forml 310-1 (PevAlIOI Pmvkpms *Mtan* w~a im ue"s

NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) ow Na E20404O4 DISCI"RGE MONITORING REPORT (DMR)

ERMITTEE NAME/ADDRESS (Ifiud Fadmy*NamnLocikm lDrWWiQ Page 9 NY0020109 001F '

4AME: ENTERGY NUCLEAR FITZPATRICK DMR MAILING 12P CODE: 13093

%DWRESS: 268 LAKE ROAD EAST PERMIT NUMBER] IDISCHtARGE NUMBER MAJOR LYCOMING, NY 13093 (SUBRO7)

ACIUTY: ENTERGY NUCLEAR FITZPATRICK I ER MONITORING PERIODI BORATED WATER ISURVEIL. TEST.)

.OCATION: 268 LAKE ROAD EAST Exsmral Outlali LYCOMING, NY 13093 No Date IndloatarE FROM I 1 10 01 0 10 311d

,TTN:T A SULLIVAN NO. uauc SAMPLE PARAWT.ER.. .*: QUANTITY OR LOADING QUALITY OR CONCENTRATION VALUE VALUE UNITS VALUE VALUE VALUE UNITS Ro atS AMPLE . ... . .. .

IMFASUREMENT __ .-.

XK05 INO0 PERMIT ~~~

Mowed Incvaso REQUIREMENT ga*---r 3oron. total (as B) SAMPLE ............

MEASUREMENT _______-__ ___....................__............ ...... - -.-. -

MOM IN 0 PERMIT A~

MJowed Itbcias REQUIREMENT L. . .'-- ~ ______~~rgL____

NAMEMTTLE PROIPCAL EXECUTIVE OFFICER

1. DIETRICH 1ITE VICE PRESIDENT TYPED I IMENTB AND EXPilNATION OF ANY VIOLATIONS (Adurms all aflaclmal hsm) tForm I32O-1 4Agv.Mj) Plewlaus uitions may be ued.

NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

OWONt 2040-004 DISCHARGE MONITORING REPORT (OMR)

RMrrTEE NAME/MAORFSS (hdO FANdlWtLamotn UD#hr9mn Pagp 10 14NY002DI09 001 WME: ENTERGY NUCLEAR FITZPATRICK OMR MAILING ZIP CODE: ¶3093 DORESS: 268 LAKE ROAD EAST PERMITJNU ER I ISC H N ER MAJOR LYCOMING, NY 13093 (SUBR07)

ICIlUTY: ENTERGY NUCLEAR FITZPATRICK

)CATION: 268 LAKE ROAD EAST IYEAR I MONITORING PERIOD IDAY I SERVICE WATER Exmemal Outfall LYQOMING, NY 13003 Do I o IYEAR MOI 01 TO L_ ¶0 31DA No DfbasiO[

FROM P064 10 TTN:T A SULLIVAN

X S <CtNO. ntouie~vSAMPLE PARATE.IA QUANTITY OR LOADING QUALITY OR CONCENTRATION E NfLTM TYPE

<CX' 4, VALUE VALUE UNITS VALUE VALUE VALUE UNITS H SAMPLE MEASUREMENT ..... 7.8 8.4 SU 0 DAILY GRAB 0400 IN 0 Mowed Increase PERMIT  : f r.C  % 4,.# 4 .C"'<

REQUIREMENT ____ _____________

low, incndut o t teatent SAMPLE 27.5 54.0 , gal/d *... -U rrrr 0q .7 OMsINo PERMIT 'V.' V.t<*

Wowed Increase REUIEMN C << ,'<<""C"4 41t MgMaL aa MESRMN 0.07 mg/L 0 OCCURS GRAB

0080 IN0 PERMIT
. .: 4 t? 2.'* <<:C 4.40-< f

<S~~4<C<<

<X<(* 7 '. .t'*....

Wlowed Incemase REQUIREMENT '<<<*XC 7 n, C<C<4 44C

<"<<:"44 <i.. \,4'X'/'4".......

4XX<4 e4'b*.V

... 4<]L

<< nvjI.

  • L*4WW IMMENT3 AND EXPLNATION OF ANY VIOLAI*O (Rslur AN mlaclmvda lieo)

EE FOOTNOTE F REGA*MG CHLCRINEAN PH

NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

DISCHARGE MONITORING REPORT (WibR) Owa ML 2l040.0=

'ERMITTEENAME/ADORESS (Nl k FadetyAnacaI IDtuo/ewnW Pap 11

%lAME:

WDORESS:

ENTERGY NUCLEAR FITZPATRICK 268 LAKE ROAD EAST PRITNUMBERo .0- hME DR MAILUNG ZIP CODE: 13093 LYCOMING, NY 13o03 MAJOR

  • ACILITY: ENTERGY NUCLEAR FITZPATRICK fSUBR07)

.0CATlON: 268 LAKE ROAD EAST IOUNITORING PERIOD REVERSE OSMOSIS LYCOMING, NY 13093 IYEAR MO DAYI IVARI MO ]DAY Exftnd Ou~d kTTN:T A SULLIVAN FROM 16 101I01 1 TO 0mo8 10 31 No Date hidaml.4 Ap * +i**;*::*::*!*.*!:i: QUANTITY OR LOADING PA~kEW QUALITY OR CONCENTRATION NO. FrAsuacy SAMPLE Ii VALUE TT OF TYP I

VALUE UNITS VALUE VALUE VALUE UNITS SAMPLE ...

MEASUREMENT 7.9 I D0400 INO PERMIT  :

8.0 SU 0 WEEKLY GRAB Ulowed Increase .

REQUI REMEN ... - :Rs m.Xv'

::::::::  :****..*¢. .
  • __-*:;; ....

lID OR -

,m

  • MENTWS AND EXP.A*NATON OF ANY YJO.ATION45 (ReueuwA all Wstumneuim here) k um 3a-1 m~v@mmm) prommnOdomMonma be u"ed

NATIONAL POLLUTANT DISCHARGE EUMINATION SYSTEM (NPOES) Fu0mApW~

OW W. 20404X04 DISCHARGE MONITORING REPORT (OUR)

RMOTEE NAME/ADDRESS (xfuid FadjtyNetocskinjUftwrw) Pag 12 NUBR I S NY002D109PRI I O1J AME: ENTERGY NUCLEAR FITZPATRICK OUR MAILING ZIP CODE: 13093 DDRESS: 268 LAKE ROAD EAST IE DISCHARGE NUMER MAJOR LYCOMING, NY 13093 (SUBFR7)

ACILITY: ENTERGY NUCLEAR FITZPATRICK EMERGENCY DIESEL NIC COOUNG MONITORING PERIOD OCATION: 288 LAKE ROAD EAST ExbmaW Oudali LYCOMING, NY 13093 i EAR I MO IoYI TIEARI MO IDAYI FROM 06 110101 ITO 06 10 131d No D@W hdimtoat kTTN:T A SULLIVAN NO. mwIuexCY SAMPLE PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION VALUE VALUE UNITS VALUE VALUE VALUE UNITS SAMPLE ,- ,

MEASUREMENT .... 7.8 8.4 SU 0 DAILY GRAB 0400 IN40 PERMIT ~-* '

dlowed Increase REQUIREMENT ___. - W ' ' . '. PPJ  ;., su . : ' .

s______________

u.________. .  :'

low, in conduit or thu treatment plant SAMPLE CONTIN-MEASUREMENT 0.09 0.18 Mgal/d ....... -_..... 0 UOUS CALCTD 00501N0 PERMIT '. flo...*: ml1 - ý . - .

Jlowed Increue REQUIREMENT dMWJ'A -' ..O.... M:aw .. .:: 5: ..- F.**

'*.' d.z*.

hons. tal reidul SAMPLE - CLRNTN MEASUREMENT _ "_ _________ 0.07 mg/L 0 OCCURS GRAB 0060 IN 0 PERMIT - M U;NI -

Mowed Increase REQUIREMENT _: ___: ____ýZ A:* .:._____:___: - .:

  • V".: . .:g. . -.

NAMEITITLE PRINCIPAL EXECUTIVE OFFICER d" b Mpodmmpmm d o 1.%W Fdtwa ma'7 1 ddw

  • ~~~~~= ' - - *- * * . ., ~ mH.--
  • D* I a Tv fI*5 3 15 3 4 2- 3 8 4 0 06 11 20

.. ',- U- F Al,.--F--O-.e

-m" - * --

ITE VICE PRESIDENT

)MMENTS AND EXPLANATION OF ANY VIOLATIONS llleoleunlmnlo -a slne two) helm)

IANMGHWRME, ARE REPEATEDVALUES OF"THEREPRESENTATIVEGRABAT001H. A and C Emergency Diesel Generators A FOrM &10-I fRav Bil-M) Pmv" att;n- -, - --- n

NATIONAL POLLUTANT DISCHARGE EUMINATION SYSTEM (NPDES)

DISCHARGE MONITORING REPORT (OMR) OW6 No. 204040004 ERMITTEE NAMIFEADDRESS (kxA1 FactftNmnwLamctm lD#%wV lAME:

S NY002DOLOC0 Page 13 ENTERGY NUCLEAR FITZPATRICK I PE~ffNUL-Rý DISCiHARGE NUMBER DMR MALING ZIP CODE: 13093 U)DRESS: 268 LAKE ROAD EAST LYCOMING, NY 13093 MAJOR

ACIUTY: ENTERGY NUCLEAR FITZPATRICK (SUBR07)

.OCATION: 268 LAKE ROAD EAST MONITORING PERIOD EMERGENCY DIESEL N/C COOUNG LYCOMING, NY 13093 IYEAR I MODAYI IYEARI MO IDAYI Exlemal Outilf I.1TN:T A SULLIVAN FRO 01 10 101 TO 106_ 10_ 31 No Doaa Iulicalor[

SOUANTI[T OR LOADING OR.

PARAMETER....... ... ____ _______ _______

QUALITY OR CONCENTRATION NQ uac SAMPLEC

___ EX OF, .____ TYPE VALUE VALUE UNITS VALUE VALUE VALUE UNITS d-H SAMPLE MEASUREMENT ....

)0400IN0

_7.8 8.4 SU 0 DAILY GRAB PERM1IT' I Wowed Increase________

.~

4

~,'~~* ýz'"

M ~ su ~ ~ '" ____

Io, i ~MEArSUREMENTnplat cic 0.14 0.23 Mgal/d _____

x005 IN 0

____0 UQUS CALCTD PERMIT Wowed Incrame REREME4I s~

moa .. J6 ZA~

Jý .N'

wwta

~hona. au SAMPLE

~t DSdUIMEASUREMENT .

- ____0.07 CLRMT 0060INO mg/L 0 OCCURS GRAB PERM11T 4w 77.7~~

~Mowed Increase REQU1IREMEN'T _______________

~u~i

_______jmf

)MUENTS AND EILANATION OF ANY VIOLATIONSl Irumsm ON dmtnefni her)

I AND CHLORINE ARE REPEATED VALUES OF THE REPRESEN'ATIVE GRAB AT 001H.

A Form 3320-1 (RevAM)0U Previous *=ton* nwV bo usin

NATIONAL POLUMTANT DISCHARGE ELIMtNATION SYSTEM (NPDIES FOmApB. -d ow tNm 20404004 DISCHARGE MONITORING REPORT (DMR)

RMITTEE NAMEIADDRESS (kndude FaciIy NwramWo Pop 14 if DNmiun)

I NYO002109 001 PERITHMBE l 01M OUR MAILING ZIP CODE: 13093 AME: EN-TERGY NUCLEAR FITZPATRICK DORESS: 268 LAKE ROAD EAST PERMTNUMBFAý DISCHARGE NUMBER MAJOR LYCOMING, NY 13093 (SUBR07)

CILUTY: ENTERGY NUCLEAR FITZPATRICK OCA'ION: 268 LAKE ROAD EAST I MONITORING PERIOD I OUTFAIL 001 ExlemmI Oullall IYEARI IOAY I MO IE 1 Mo LYCOMING, NY 13093 FROM O6 10° °01 1 TO 06 1 10 1 1 No Da- b,--I-t-o L1TN:T A SULLIVAN

...  : QUANITY OR LODING UAUTY OR COCENTATIO NO. unaogs~c SAMPLE PARAMETER O UAl~t"A I OR EL aONCENTsRATaMv IS PLE VALUE VALUE UNITS VALUE VALUE VALUE UNITS "mperaturo, watar dog. fahrenheit SAMPLE "__ tt*** 66.3 CONTIN-MEASUREMENT 66.3_ 90.7_ deF0_OU__CO 40011 10 PERMIT , .x;' -O9r'L ..... 'AmJ

.tfnuent Gross, __ :X__

__ __ __ _ __' F__

SAMPLE .0 AYB MEASUREMENT ..... 7.8 _ '-- 8.4 S] 0 DAILY RAB X)04 1 0 PERMIT ,... . . .. * ..........

.ffluent Gross RlQUfPEJ . . : * , ..

5& g-

)lm SAMPLE ONCE/

< 5.2 mg/L 0 MONTH GRAB EffluentGross REQUIREMENT .:::.

-,LAMTROL CT-1, TOTAL WATER MAUEMEN%__~~T MESAMPLE __ODI9__ _m_/L_ ,gIL NODI9 0 isHG 0__GRAB W4251 1 0 PER I zk m;- ,,, -,

Effluent Gross ______ wEUIEMNA-_______

SAMPLE - CONTIN-

low, conduitor h tment plant MEASUREMENT 175 570 gal/d _"__--_ 0 UOU; CALCTD A0050 10 PERMIT . "

Effluent Gross REQUIREMENTT L.,y.. __________.._ * , - , ' .  :

SAMPLE told-- .. _.MP.EWHEN hioRnne, tot0.2d U,_MENT ____._ m_-/L 0 DSCHG RAB 00601 0 PERMIT .

lot rate of adliCtic heat SAMPLE .

MtAtURtMENTo l 1.72 5.22 (BTU/hr 0 DAILY CALCTD 157520 PERMIT m' I ~ ~ ~~~

,ffluent Net REQUIREMENT ;'GZu I . I GHTYhr..'-:

u.::w .

NAMETIfTLE PRINCIPAL EXECUTIVE OFFICER DAd" P. DIETRICH Yom% 4b u6.,I 120 SITE VICE PRESIDENT . -- , --- OF06CER OR 315 315-342-384342-3840 06 11 T____4_W O__ RUTIVE -- RCE Rk O TYPED ON PRNTED 1, AUThORIM ZED T WiDR VM OD OMMENTS MAD EXPLANATION OF AMY VIOLATIONO (RMhueWn INt m1lacn1=01 hef) , -

ISCHARGEINTAJ(E TEMPERATURE DIFFERENCE &NET RATE OF ADDITION OF HEAT MAY EXCEED LIMIT BY 5% DUE TOTHERMOOYNAMIC RUCTUATION INTHE PRocES8 STEAM cYCLE. ENTER MODI UN PLAGE OF A EAsUREMENT WHEN A-ARAMETER DOES NOT APPLY DURING THE ENTIRE MONITORING PERKI).

DA 5.0.m £IMILI fu.. E ID Mam A- ~

-~..... --

  • NATIONAL POLWTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

OMB NIL amowdC DISCHARGE MONITORING REPORT (DMA)

'ERWITrEE NAME/ADDRESS (bi*l FaiYatyNM4rackbi tDIww4 Pap 15 0AME: ENTERGY NUCLEAR FITZPATRICK DM MAILNG ZIP COOE: 13093 WDDRESS: 266 LAKE ROAD EAST PERMIT NUMBER DISCHAGE NUMBER MAJOR I

LYCOMING, NY 13093 (SUBRO7)

FACILITY: ENTERGY NUCLEAR FITZPATRICK OCATION: 268 LAKE ROAD EAST

.EA MONITORING PERIO I OUTFALL 001 ExbmaI Ouaell LYCOMING, NY 13093 YEAR oI DAYI IYEAR IO I DOA FROM1 06 10 1 TO 06 10 31 NW DWAt k~dkatoIO IkTTN:T A SULLIVAN NO. Percy SAMPLE PARAMETER QUANTITY OR LOADING OUALITY OR CONCENTRATION oxi.was OF TYPE VALUE VALUE UNITS VALUE VALUE VALUE UNITS romp. itt. bownnI.m an SAMPLE _ , _ _ CONTIN-IREMENTAS-U EME,,,. 6.*5 25.3 degF 0 UOUSRCORDR 11576 2 0 ,. . OPERM L:* IT

-RE *.,, .;i :. : :*,,q::ii* '**** ::. ::;.:.i;*:

.  :.pf:

ffluent Not R. I MENT 4"?" ..... de dog.F .. .. ... . . .............. ..

6110011 MID EXPLANATION OF MY VLI.ATIONS 00femfral-l llactuna'i twa)

CHARGEWTAKE TEMPERATURE DFFE
IENCE & NET RATE OF ADDITION OF HEAT MAY EXCEED LMIT BY 5% DUE TOTFWRMOYNAMIC I APIIRFUFMT APARAUF7EFR Do1S NOT APPLY DURING THF ENTIRE MONITORING PERIOD.

.WM4FN POrn, N2-1 IRWv*ARS) PvW4aua ejtlon MW be Us"

%~

NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) FOMAPPuved DISCHARGE MONITORING REPORT PDAR) 0W Nm 20404004 RMITEE NAMNEADDRESS (kwd Fad,*yNam tocufiui Dlffwmen) Pagp is WME: ENTERGY NUCLEAR FITZPATRICK SNY002oDo, ools . DMR MAILING ZIP CODE: 13093 DORESS: 268 LAKE ROAD EAST ,PERMIT NUMBER Lr3 KlCAGEE NUMBER J LYCOMING, NY 13093 MAJOR lCILUTY: ENTERGY NUCLEAR FITZPATRICK /- MO MONITORING PERIOD -DY (SUBR07)

WASTE NEUTRALIZATION TANK-ANN.

)CATION: 268 LAKE ROAD EAST LYCOMING, NY 13093 ],EARI . DAY I YEAR I MOA MO I External Oulltul TTN:T A SULLIVAN FROM1 0 111 101 TO 06 1 10 311 No Dan Indlout-o PARAMETER QUANTITY OR LOADING QUAUTY OR CONCENTRATION NO. moaue.cl SAMPLE o_ ________,_ VALUE O AWLYT TYPE VALUE

___________ V

_,UNITS__YPE VALUE VALUE UNITS VALUE VALUE VALUE UNITS

)Id&greas MEA LEURMN1- < 5.1 g/TL 0 GRAB 0556 IN0 PE I I. f 7..*

7*7*.7 7. *' *- 4 Jlowed Inclm RMUI.MN x.:~- R*-1 N g NAMEMTITLE PRINCIPAL EXECUTIVE OFFICER *wa yI*,A, o iuwa dm*,,,o,,"m,, I**_wm6W.DATE P. DIETRICH SITE VICE PRESIDENT 315 32-3840 06 11 20 PI NCIPAL EXEWTIVE OFf CER OR Im! mI 2 TYPED OR PR(mTED f- AG MOUMENTS MAD EXPLANATION OF ANY VIOLATIONS ll(hkusenmo alladechmens hsm)

NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

OMB N 2040-MG4 DISH4ARGE MONITORING REPORT (PMR)

'ERMITTEE NAME/ADORES (k/da. FadwyNvwncthm f#OkWw Pag 17 4AME: ENTERGY NUCLEAR FITZPATRICK NlY002109 IPERMIT NUMBER 001Yzzz P-DISCHARGE NUMBER]

DMA MAIUNG ZIP CODE: 13093 WDORESS: 268 LAKE ROAD EAST MAJOR LYCOMING, NY 13093 (SUBR07)

ACIUTY: ENTERGY NUCLEAR FITZPATRICK

.OCATION: 268 LAKE ROAD EAST I MONITORING MP1 D I CLARIFIER BLWDN ANNUAL SAMPLE Exlemal Oufaill LYCOMING, NY 13093 YVEAR, MO IDAYI IYEI DAY FROM 05 11 101 TO 06 1 10 311 No DaMa Indio[etw

'T"N:T A SULLIVAN NAMEMITLE PRINcWAL ExECUTrIE OFFICER a A P. DIETRICH =. D=ETRH h.,, . ..- ,* nt..am....,.1"-.l...'*.'. 's'9* %Orrio 315 342-3840 06 11 20 31TE VICE PRESIDENT ,

ps~tx*W*wfm~"0 l m-*e*I,,ee m*amq~r A*L EMZU _a OFCE o ORm "H.Amq W.0 go DAYE DAY TWPFD OR PRIUNTED AGE,

)MEONMS ND EXPLANATION OF ANY VIOLATIONS pjftmnroe sol alblumuns her.)

A Form &320-1 (PV.oMOIXPvedUo may be used WHboMp

FwmAWPMM NATIONAL POLLUTANT DISCHARGE EUMINATION SYSTEM (NPDES)

OW No. 204-OOO4 DISCHARGE MONITORING REPORT (DMR)

Pap 1is "MUnT-E NAME/ADORESS (#hcukFmdJyANDnmLoctoi D#W"n AME: ENTERGY NUCLEAR FITZPATRICK DMR MILdiG ZIP CODE: 1303 DDRESS: 268 LAKE ROAD EAST PERMIT NUMBER DISCHARGE NUMBER MAJOR LYCOMING, NY 13093 (SUBR07)

WCILITY: ENTERGY NUCLEAR FITZPATRICK aCATION: 268 LAKE ROAD EAST F  ? MONITORING PERIOD I ANTHRACITE FLR BKWSH-ANN. SAMP Exemai Outfal R EAR 1DAY MO 0I T 0IO 10 LYCOMING, NY 13093 O I o I 11 1 0° R 1 10o1 31 No Data hIodmtorEI

.TTN:T A SULLIVAN NAME/TITLE PRINCIPAL EXECUTIVE OFFICER Ea. DATE P. DIETRICH 315 342-3840 06 SITE VICE PRESIDENTpuaca 11 20 m= PIOLEftMFICRR MODAY TYPED OR PRINT ED.AE A ,n uachnma ham)

)MMENTs AND EXPLANATION OF ANY VYOLATION5 (RAlmncem all