E-mail from D. Croulet of Entergy to Various, Regarding Monitoring Well Status - February 15, 2006-1700 Hours
ML061320212
Person / Time
Site: FitzPatrick 
(DPR-059)
Issue date: 02/16/2006
From: Croulet D
Entergy Nuclear Operations
To: Noggle J
NRC/RGN-I/DRS/PSB2
References
FOIA/PA-2006-0140
Download: ML061320212 (7)


Text

[ Jarmes i4oggle - FW: MONITORING WELL STATUS-FEBRUARY 15, 2006-1700 HOURS Page 1 From:

"Croulet, Donald" <dcroule@ entergy.com>

To:

"Conroy, Pat" <PConroy~entergy.com>, "Cox, Mark R" <mcox9Oentergy.com>,

"Bowman, Greg " <GBowm9O © cc--exsO3.prod.entergy.com>, "Janicki, John" <JJanick @ entergy.com>,

"'James Noggle"' <JDN@nrc.gov>, "'Timothy Rice"' <tbrice@gw.dec.state.ny.us>, "PRICE, ERNEST JR"

<EPRICE2@ entergy.com>, "Robert Oliveira (boliveira@ amnucins.com)" <boliveira @ amnucins.com>

Date:

2/16/06 6:57AM

Subject:

FW: MONITORING WELL STATUS-FEBRUARY 15, 2006-1700 HOURS From: Sachatello, Ronald Sent: Wednesday, February 15, 2006 4:55 PM To: Rutkoske, Michael; Skonieczny, John; Thiery, Al; Drake, Richard; Nuta, Dragos A; Bode, Paul M.;

Deeds, Paul; English, Christopher; Peters, James; Wilson, Daniel; Sandike, Steven; Kulaga, Joe; Morin, Kenneth; Croulet, Donald; Durfee, Michael; Hinrichs, Gary; Evers, Bob; Loope, Dennis; McMullin, Kathy; Burns, Thomas; Colville, Richard; Zolotas, William; Daniele, John C.; Colville, Howard J.; Halcomb John W; Bryant, Sandra; Quinn, Dennis; 'mbarvenik~gza.com'; 'David Winslow'; Tamburi, Robin M.

Cc: Axelson, William L; Mayer, Don; Sachatello, Ronald

Subject:

MONITORING WELL STATUS-FEBRUARY 15,2006-1700 HOURS

<<MONITORING WELL STATUS.doc>>

MW-32 Packer Testing in Progress MW-39 Developing well MW-40 Borehole geophysics in progress MW-41 Drilled 25' of 65' MW-46 Drilled to 30'

MONITORING WELL STATUS (Feb 15, 2006-0600 hours)

Well Number MW-111 MW-30 MW-31 MW-32 MW-33 MW-34 MW-35 MW-36 MW-37 Location Transformer Yard U-2 SFB MOB side walk U-2 SFB Alley Way Transformer Yard Transformer Yard Transformer Yard U-2 Turbine Bldg U-2 Turbine Bldg Status Baseline Sample PT In service In service In service In service In service In service In service Developed Next Step Sampled (02/07/06)

Continue to sample Install permanent Packer Most recent sample Sampled 02/07/06 Sampled 02/07/06 Sampled 02/07/06 Sampled 02/07/06 Sampled 02/07/06 Sampled 02/07/06 Sampled 02/10/06 Sampled 02/10/06 NEM to take samples Current Results (I

238,000 pCi/L Raw Water (no Packer)

Highest Packer Water:

Low Flow Samples:

33,100 pCi/L 17,700 pCi/L 214,OOOpCi/L 174,000 pCi/L 84,500 pCi/L 26' =20,000 pCi/L 41'=47,500 pCi/L 53'=22,400 pCi/L Eliphest Historical Value) 302,000 pCi/L (11/10/05) 399,000 pCi/L (1 1/18/05) 601,000 pCi/L (11/22/05) 511,000 pCi/L (02/07/06) 33,100 pCi/L (02/07/06) 17,700 pCi/L (02/07/06) 242,000 pCi/L (01/27/06) 212,000 pCi/L) (01/27/06) 104,000 pCi/l (01/27/06) 47,500 pCi/L (02/10/06)

MW-38 South U-3 Boundary In service Continue periodic sampling Split Sample MW-38 Results:

NY State Result: 701 pCi/l (12/08/05)

Fitzpatrick Result: 985 pCi/l (12/08/05)

Non Split-Fitzpatrick Results only Fitzpatrick Result: N.D.

(12/30/05)

Fitzpatrick Result: 1008 pCi/l (01/10/06)

Fitzpatrick Result: 758 pCi/L (01/19/06)

Fitzpatrick Result: 1,444 pCi/L( 01/25/06)

Well Number Location Status Next Step Current Results (Highest Historical Value)

MW-40 MW-48 MW-39 MW-46 MW-42 MW-47 MW-41 MW-45 MW-44 MW-51 Lot above Sewer Plant Furthest South Well Ul SFB IU3 RWST U-3 Transformer Yard U-I CTMTJU-2 Diesel Area West side of U-1 South of U-3 RWST U3 between Aux and SFB U3 North of SFB South, upgradient to MW-40 Well developed Well developed Well completed Drilled to 30' Needs to be relocated Vacuumed to 7' Drilled 25' of 65' Needs to be relocated Vacuumed to 7' Vacuuming in progress Count samples Count samples Develop well Complete well Begin drilling Complete well

CURRENT WELL STATUS Phase I Wells MW-30 MW-31 MW-32 MW-33 MW-34 MW-35 MW-36 MW-37 MW-38 Status Completed Completed Completed Completed Completed Completed Completed Completed Completed Phase II Wells Sequence (see note below)

Status (Feb 15. 2006)

MW-39

  • MW-40
  • MW-48
  • MW-42
  • MW-46
  • MW-41 MW-43 MW-44 MW-45 MW-47 MW-49 MW-50 MW-51 MW-52 South of Unit 1 Fuel Storage Building Parking Lot above Sewerage Plant Furthest Southerly Property Boundary West of Unit 2 RWST West of Unit 3 PAB Sump South of Unit 3 RWST South of Unit 3 Tank Pit and RWST North of Unit 3 Fuel Storage Building Between Unit 3 Fuel Storage Building/PAB West of Unit 1 Fuel Storage Building West side of Unit 3 Discharge Canal East side of Unit 3 Disgharge Canal Southern property hill north of MW-40 Northern property boundary (developing)

(in service)

(in service)

(needs relocation)

(drilling)

(drilling)

(vacuumed-ready to drill)

(vacuumed-ready to drill)

(needs relocation (Vacuum completed)

(Ready to vacuum)

(Ready to vacuum)

(vacuumed-ready to drill)

(Location not established)

  • Note:

Wells numbering 39, 40, 48, 42, 46 are priority wells at this time and may be drilled, developed, and sampled in a changing sequence within this subset based on depth of well considerations, equipment setup options, engineering paperwork delivery, and development status.

RECENT INFORMATION:

(Activity in pCi/L)

MOST RECENT RESULTS (in nCiUL)

MW-30 511,000 (02/07/06)

MW-31 33,100 (02/07/06)

MW-32 17,700 (02/07/06)

MW-33 214,000 (02/07/06)

MW-34 174,000 (02/07/06)

MW-35 84,500 (02/0706)

MW-36 47,500 (at 41')

(02/10/06)

MW-ill 238,000 (02/07/06)

Algonquin Gypsum Trap Rock ND ND ND (02/04/06)

(02/04/06)

(02/04/06)

TREND INFORMATION DATE:

MW-30:

MW-31:

MW-32:

MW-33:

MW-34:

MW-35:

MW-ill:

MW-38:

11/22/05 12/13-16 464,000-601,000 12/19/05 12/30/05 01/06/06 4,061 142,000 199,000 220,000 189,000 63,900 121,000 147,000 159,000 42,300 76,000 80,500 95,400 296,000 192,000 212,000 113,000 Most recent Split Sample results: 985 (Fitzpatrick 12/08/0 Most recent Fitzpatrick results:

Not detected (Fitzpatrick 1,008 (Fitzpatrick 01/10/C 758 (Fitzpatrick 01/19/C 1,440 (Fitzpatrick 01/25/C 01/13/06 01/20/06 01/27/06 02/01/06 119,000-319,000 ( 1/30/06) 4,030 656-2,160 7910 221,000 3,720 7,110-11,110 well not available 232,000 226,000 242,000 250,000 131,000 211,000 212,000 224,000 97,800 104,000 38,700 51,300 199,000 119,000 Recounting 295,000 15))

701 State of New York (12/08/05)

Unit 2 Storm Drain Jan 19, 2006 (pCi/l)

Jan 24, 2006 Jan 30.2006 MH1 (U-2 riverfront)

ND MH2 (U-2 riverfront)

ND ND ND MH3 (North end of U-2 Turbine) 2,240 2,190 MH4 (Entrance to U2 Transformer Yard) 3,780 1,180 MIH5 (U-2 Aux Feed Bldg) 3,570 1,070 MH6 (U2 Transformer Yard) 18,600 50,500 MH7(U2 Transformer Yard) 3,840 7,300 MIH8 (12 Transformer Yard) 3,210 9,580 M112 (U2 Riverfront)

ND ND ND MH14 (U2 Riverfront)

ND ND CB 15 (U2 Riverfront)

ND ND Unit 3 Storm Drain Manholes taken Jan 19, 2006 (pCi/I):

A2 (Near U-3 RWST)

ND A4 (Near U-3 RWST) 1,190 A6 (Near U-3 RWST) 686 B5 (Entrance to 3 Transformer Yard) 3,320 El (Unit 3 Roadway to Security Post)

ND E2 (Unit 3 Roadway to Security Post)

ND E2B (Unit 3 Roadway to Security Post)

ND E3 (Unit 3 Roadway to Security Post)

ND E3A (Unit 3 Roadway to Security Post)

ND

TREND COMPARISON Unit 3 Storm Drain Locations 01/19/06 01/17/06 01/12/06 A2 U3 RWST ND A4 U3 RWST 1,190 A6 U3 RWST 686 B 1 U-3 Transformer Yard 5010 4530 B3 U-3 Transformer Yard 4650

~

6280 B4 U-3 Transformer Yard 3600 3180 B5 U-3 Transformer Yard 3,320 B6 U-3 Transformer Yard ND B7 U-3 Transformer Yard 2690 2510 B8 U-3 Transformer Yard ND Cl U-3 North of Service Bldg 867 997 D2 U-3 South of Service Bldg ND ND E4 U-3 Access Road to Command Post ND El U3 Access Road to Command Post ND E2 U3 Access Road to Command Post ND E2B U3 Access Road to Command Post ND E3 U3 Access Road to Command Post ND E3A U3 Access Road to Command Post ND E4A U-3 Access Road to Command Post ND E5 U-3 Access Road to U3 Command Post ND E5A U-3 Access Road to U3 Command Post ND E6 U-3 Access Road to U3 Command Post ND E7 U-3 Access Road to U3 Command Post ND