NOC-AE-060019, Proposed Amendment to Technical Specification 6.8.3.j for One-Time Extension of Integrated Leakage Rate Test Interval to 20 Years

From kanterella
(Redirected from ML062910349)
Jump to navigation Jump to search
Proposed Amendment to Technical Specification 6.8.3.j for One-Time Extension of Integrated Leakage Rate Test Interval to 20 Years
ML062910349
Person / Time
Site: South Texas  
Issue date: 02/28/2006
From: Jordan T
South Texas
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
G25, NOC-AE-06001963, STI: 31976661
Download: ML062910349 (64)


Text

Nuclear Operating Company South TexasPro/ect E/etdc Gunerat/lg Sa.I1on P.O Box-289 Hhdvorth, Teas 7748)

February 28, 2006 NOC-AE-06001963 File No.: G25 1 OCFR50, Appendix J 1 OCFR50.90 U. S. Nuclear Regulatory Commission Attention: Document Control Desk One White Flint North 1155 Rockville Pike Rockville, MD 20852-2746 South Texas Project Units 1 & 2 Docket Nos. STN 50-498, STN 50-499 Proposed Amendment to Technical Specification 6.8.3.j for a One-Time Extension of the Integrated Leakage Rate Test Interval to 20 Years

Reference:

"Proposed Amendment to Technical Specification 6.8.3.j for a ClIange in 10CFR50 Appendix J Integrated Leakage Rate Test Interval," J. J. Sheppard to NRC Document Control Desk, dated August 2, 2001 (NOC-AE-01001115)

Pursuant to 10CFR50.90, the STP Nuclear Operating Company requests Nuclear Regulatory Commission review and approval of a proposed amendment to the South Texas Project Technical Specifications.

The South Texas Project previously received Nuclear Regulatory Commission approval of a one-time extension of the ten-year period of the performance-based leakage rate test program to 15 years for Type A tests, as requested in the referenced correspondence. This application requests an additional five years, for a total of twenty years between integrated leakage rate tests as a one-time extension.

Justification for the extension is based on the following:

" Probabilistic risk assessment demonstrates the increase in Large Early Release Frequency is less than 1.OE-07.

Previous test results show considerable margin.

Ongoing inspections show no structural degradation has occurred.

Future inspections will ensure identification of any structural degradation.

Containment venting confirms the structure as being low leakage.

The Electric Power Research Institute previously submitted for NRC review a technical report on the risk impact of extended integrated leak rate testing intervals. The NRC subsequently issued a request for additional information.

STPNOC provides as Attachment 4 responses to the questions as they relate specifically to the South Texas Project.

The South Texas Project Plant Operations Review Committee has reviewed the proposed amendment and recommended it for approval.

STI: 31976661 A 0 V7

NOC-AE-06001963 Page 2 of 3 In accordance with 10 CFR 50.91 (b), the South Texas Project is providing the State of Texas with a copy of this proposed amendment.

There are no commitments included in this request.

The South Texas Project requests feedback from the Nuclear Regulatory Commission no later than May 31, 2006, as to whether the proposal is viable for approval to support the Unit 2 outage currently scheduled for March 2007.

Although this request is neither exigent nor an emergency, prompt review by the Nuclear Regulatory Commission is requested.

If there are any questions, please contact either Mr. P. L. Walker at (361) 972-8392 or me at (361) 972-7902.

I state under penalty of perjury that the foregoing is true and correct.

Executed on T. J. Jordan Vice President, Engineering PLW Attachments: 1) Proposed Amendment to Technical Specification 6.8.3.j for a One-Time Extension of the Integrated Leakage Rate Test Interval to 20 Years

2) Reactor Containment Design and Construction
3) Application of Regulatory Guide 1.174, "An Approach For Using Probabilistic Risk Assessment In Risk-Informed Decisions On Plant-Specific Changes To The Licensing Basis"
4) Response to Request for Additional Information (RAI) Regarding EPRI Technical Report 1009325, "Risk Impact Assessment of Extended Integrated Leak Rate Testing Intervals"
5) Proposed Technical Specification Changes

cc:

(paper copy)

(electronic copy)

Bruce S. Mallett Regional Administrator, Region IV U. S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, Texas 76011-8064 Richard A. Ratliff Bureau of Radiation Control Texas Department of Health 1100 West 49th Street Austin, TX 78756-3189 Jeffrey Cruz U. S. Nuclear Regulatory Commission P. 0. Box 289, Mail Code: MN1 16 Wadsworth, TX 77483 C. M. Canady City of Austin Electric Utility Department 721 Barton Springs Road Austin, TX 78704 A. H. Gutterman, Esquire Morgan, Lewis & Bockius LLP Mohan C. Thadani U. S. Nuclear Regulatory Commission Steve Winn Michael A. Reed Texas Genco, LP C. Kirksey City of Austin J. J. Nesrsta R. K. Temple E. Alarcon City of San Antonio Jon C. Wood Matthews & Branscomb STI: 31976661

ATTACHMENT 1 PROPOSED AMENDMENT TO TECHNICAL SPECIFICATION 6.8.3.J FOR A ONE-TIME EXTENSION OF THE INTEGRATED LEAKAGE RATE TEST INTERVAL TO 20 YEARS STI: 31976661 NOC-AE-06001963 Page 1 of 30 SOUTH TEXAS PROJECT UNITS 1 AND 2 PROPOSED AMENDMENT TO TECHNICAL SPECIFICATION 6.8.3.J FOR A ONE-TIME EXTENSION OF THE INTEGRATED LEAKAGE RATE TEST INTERVAL TO 20 YEARS

1.0 INTRODUCTION

Pursuant to 1 OCFR50.90, the STP Nuclear Operating Company requests an amendment to South Texas Project Technical Specification 6.8.3.J extending the interval between integrated leakage rate (Type A) tests of the reactor containment buildings.

The proposed amendment will allow for a one-time extension of the interval between Type A tests from 15 years to 20 years for Unit 1 and Unit 2.

This one-time extension request is supported by the containment building construction characteristics and previous test history of the South Texas Project.

The containment structure demonstrated leak-tightness in previous Type A tests, and an ongoing need to relieve pressure differences demonstrates that leak-tightness continues. The effects of aging on the containment structure are considered and found to be minor for the proposed extension, especially in light of ASME Section XI IWE and IWL inspection requirements that would identify indications of aging.

In addition, an extensive risk assessment has been performed to determine the extent of changes in risk levels as a result of extending the interval to 20 years. Conservative assumptions are made in the likelihood of occurrence of factors that could reduce the leak-tightness of containment. Baseline values are determined for accident frequencies and population dose rates for the original test interval of three in ten years and used for comparison against longer test intervals. Similar comparisons are made for Large Early Release Frequency and Conditional Containment Failure Probability. Containment liner corrosion is treated as an increase in LERF and the population dose rate; however, its contribution was found to be negligible over the 20-year interval.

Even including the postulated occurrence of corrosion, the impact of the extension on large early release frequency and population dose rate is not significant.

This change will not affect any accident parameters discussed in the South Texas Project Updated Final Safety Analysis Report. Extending the schedule will not cause a significant change in risk, cause NRC safety limits to be exceeded, nor adversely impact the health and safety of the public.

2.0 BACKGROUND

10CFR50 Appendix J specifies the leakage rate test requirements for primary reactor containments. The test requirements ensure that: (a) leakage through containment or systems and components penetrating containment does not exceed allowable leakage rates specified in the Technical Specifications; and (b) integrity of the containment structure is maintained during its service life.

The South Texas Project has adopted Option B of Appendix J, which requires that integrated leakage rate testing be performed at periodic intervals based on performance of the containment system.

NOC-AE-06001963 Page 2 of 30

3.0 PROPOSED CHANGE

3.1 Description Technical Specification Section 6.8.3.j requires the following:

A program shall be established to implement the leakage rate testing of the primary containment as required by 10 CFR 50.54(o) and 10 CFR Part 50, Appendix J, Option B, as modified by approved exemptions. This program shall be in accordance with the guidelines contained in Regulatory Guide 1.163, "Performance-Based Containment Leak-Testing Program", dated September 1995.

The current ten-year interval between performance of the integrated leakage rate (Type A) test, beginning September 24, 1991, for Unit 2, and March 10, 1995, for Unit 1, has been extended to 15 years (a one-time change).

This proposed change in the current licensing basis is a one-time extension of the test interval from 15 years to 20 years. Approval of the one-time deferral of the integrated leakage rate test would be documented with the following replacement to Technical Specification 6.8.3.j:

The current interval between performance of the integrated leakage rate (Type A) test, beginning September 24, 1991, for Unit 2 and March 10, 1995, for Unit 1, has been extended to 20 years (a one-time change).

3.2 Purpose Approval of this request to defer the test will allow the South Texas Project to achieve a substantial cost savings by not performing the Type A test for an additional five years.

Estimated cost savings for each ILRT not performed are:

Test performance expense:

$350,000

" Schedule impact expense:

$3.15 million (The test requires three days to perform at an estimated cost of $1.05 million per day in power generation. This assumes that the Type A test is the sole reason for adding three days to the refueling outage duration.)

Total expense for each Type A test: $3.5 million

4.0 TECHNICAL ANALYSIS

4.1 Definitions An ILRT failure is defined in ANSI/ANS 56.8-2002 as one in which the Type A test performance requirements are not met.

The criterion for successful Type A test performance is based on the sum of the measured Type A test upper confidence limit and the as-left minimum pathway leakage rate from all Type B and Type C pathways isolated during the Type A test.

" The upper confidence limit is a calculated value constructed from test data that places a statistical upper bound on the true leakage rate (%/24 hours). NOTE -

the upper confidence limit in this standard is calculated at 95% confidence level.

The minimum pathway leakage rate is the minimum leakage rate that can be attributed to a penetration leakage path; e.g., the smaller of either the inboard or outboard barrier's individual leakage rates.

NOC-AE-06001963 Page 3 of 30 This sum is required to be less than La for a Type A test to pass the performance criterion.

4.2 Containment Integrity 4.2.1 Containment Structural Design The South Texas Project containment structure is a post-tensioned concrete cylinder with steel liner plates, hemispherical top and flat bottom. The cylindrical portion and the hemispherical dome of the Containment are pre-stressed by a post-tensioning system consisting of horizontal and vertical tendons. The purpose of the containment post-tensioning system is to provide additional strength to resist internal pressure during postulated design-basis accidents. Design details are provided in Attachment 2.

4.2.2 Margin of Safety The South Texas Project containment structure includes a substantial design margin for pressure. The design pressure for the building is 56.5 psig, but the calculated maximum pressure that could occur following a design basis accident is 41.2 psig. The resulting design margin is 37% [56.5/41.2 = 1.37]. The design margin of safety exceeds the 10%

design margin discussed in Chapter 6 of NUREG-0800, "Standard Review Plan."

4.2.3 Containment Venting During Operation During power operation, leaks of instrument air from air-operated valves inside containment pressurize the containment building. Changes in atmospheric conditions can also result in changes in the pressure differential between the exterior and interior of the Containment building.

The increase in the building internal pressure is reduced by periodic operation of the supplementary purge system. Needing to cycle the purge system during operation is tantamount to a periodic integrated pressure test of the containment at a low differential pressure. With a large pre-existing leak, this pressurization will not occur and operation of the containment purge system would not be necessary. As experienced by the South Texas Project, the supplementary purge system relieves a pressure differential 20 to 30 times in a given month.

The fact that the containment can be pressurized by leakage from air-operated valves and pressure variation due to temperature and barometric changes implies a lack of leak paths in the containment structure. This feature is a complement to visual inspection of the interior and exterior of the containment structure for those areas that may be inaccessible for visual examination.

4.2.4 Effects of Aging Results from previous tendon examinations show that the progression of tendon pre-stress loss is close to the predicted behavior. The IWL-3221.1 (b) limit for acceptability is 95% of the predicted value.

The most recent surveillance was completed in 2004.

Using regression analysis (NRC Information Notice 99-10, "Degradation of Prestressing Tendon Systems in Prestressed Concrete Containments," October 7, 1999), the trend lines for the four tendon groups indicate that pre-stress loss will remain in the acceptable range for the life of the plant.

Technical Specification Surveillance Requirement 4.6.1.6 requires that the structural integrity of the Containment tendons be verified in accordance with the Containment Post-Tensioning System Surveillance Program. The Program is in accordance with NOC-AE-06001963 Page 4 of 30 ASME Code Section XI, Subsection IWL, 1992 Edition with 1992 Addenda, as supplemented by 1 OCFR50.55a(b)(2)(viii).

4.2.5 Plant Modifications Implementation of plant modifications should not result in more than a minimal increase in the consequences of a malfunction of a structure, system, or component important to safety previously evaluated in the UFSAR.

Modifications altering the containment structure are infrequent and would be reviewed to ensure containment capabilities are not diminished.

The South Texas Project design change control program and the 10CFR50.59 process provide assurance that safety-significant modifications are reviewed appropriately.

4.2.6 Corrosion NRC Information Notice (IEN) 2004-09, "Corrosion of Steel Containment and Containment Liner," reported several events at other nuclear power plants in which the metal containment liner (or metal containment vessel) had experienced corrosion. The causes were varied, from wood inclusions behind the liner to standing water and degraded seals.

The NRC's discussions noted that 10 CFR 50.55a requires implementation of ASME Section XI subsections IWE and IWL. STP implements these requirements via OPGP03-ZE-0075 (ASME Section XI IWE Inservice Inspection Program Unit 1 and Unit 2) and OPGP03-ZE-0076 (ASME Section XI Visual Examination for IWE Containment Inspections):

OPGP03-ZE-0075 provides the overall programmatic direction, and OPGP03-ZE-0076 provides specific implementation instructions. The OPGP03-ZE-0076 instructions implement the IEN guidance.

The NRC in particular points out a concern associated with liner floor seal degradation.

The seal is inspected at the South Texas Project. Additionally, the containment floor concrete is slightly raised at the point of the buried seal to resist water intrusion. IEN 97-10 addressed the same subject. The response to this indicated satisfactory compliance due to the ILRT process and OPEP04-ZE-0001 (Structures Monitoring) which has been initiated for maintenance rule monitoring. The OPGP03-ZE-0075/76 procedures were not yet implemented at that time but were in the development process. OPGP03-ZE-0075 references IEN 97-10.

Reviewing the Corrective Action Program database for degradation events, only three such items were noted. All of these items were found as a result of inspections and did not affect function. One situation was noted as part of the review for IEN 97-10 in which a corrosion spot was found on a ceiling joint. The corrosion was minor. IEN 2004-09 does not appear to address new issues requiring additional types of inspection.

4.3 Inspections and Tests The South Texas Project has implemented an on-going program of containment inspection and testing using the revised schedule criteria made available in 1995.

4.3.1 ASME Section XI, Subsections IWE/IWL Inservice inspection of the South Texas Project Containment buildings is conducted in accordance with the requirements of Subsections IWE and IWL of the ASME Section XI code. Subsection IWE provides the rules and requirements for inservice inspection of NOC-AE-06001963 Page 5 of 30 penetration liners of Class CC pressure-retaining components and their integral attachments in light-water cooled plants.

There is no change to the schedule for these inspections as a result of this interval extension.

4.3.1.1 Identifying Visible Degradation Examinations pursuant to the requirements of Subsection IWE of ASME Section XI and the plant protective coatings program ensure continued integrity of the South Texas Project containment liner. Under Subsection IWE, inservice inspection examinations are performed that require visual examination of essentially 100% of the accessible surface area of the containment liner once per ISI period (three in 10 years). This examination is performed and documented by qualified individuals per Subsection IWE during refueling outages. The examination is performed either directly or remotely, depending upon the accessibility of the various areas. There have been no recordable indications of liner plate degradation at the South Texas Project.

Coating condition assessments conducted as part of the structure monitoring program provide additional assurance that containment liner flaws are identified. The structure monitoring program covers the baseline inspection and subsequent inspections conducted once each period.

The condition of the coatings inside containment is characterized by visual inspection. If localized areas of degraded coatings are identified, those areas are evaluated and scheduled for repair/replacement, as necessary.

The concrete surface, including coated areas, is visually examined under ASME Subsection IWL for evidence of conditions indicative of damage or degradation. Optical aids and artificial lighting may be used as necessary to ensure the assessment is sufficiently detailed.

Examinations of the containment and the containment tendons, were conducted at one, three, five, ten, and fifteen years following the initial post-tensioning operations for Unit 1, and for Unit 2. The containment concrete surface, including coated areas, is visually examined for areas of large spalling, severe scaling, D-cracking in an area of 25 ft 2 or more, other surface deterioration or disintegration, or significant grease leakage. No damage or degradation of the concrete surfaces was identified during the examinations.

4.3.1.2 Identifying Non-Visible Degradation In some cases, a complete inspection of a section of the containment liner is not possible due to its inaccessibility. Approximately 16% of the containment liner inner surface is inaccessible for inspection because it is embedded in concrete. For these cases, the condition of the liner is characterized based on an inspection of areas that are reasonably accessible to be used as representative samples.

4.3.1.3 Augmented Inspections Augmented inspections are required if containment surface areas are likely to experience accelerated degradation and aging. As described in IWE-1240, this includes areas subject to accelerated corrosion with no or minimal corrosion allowance, areas where absence or repeated loss of protective coatings has resulted in substantial corrosion or pitting, and areas subject to excessive wear from abrasion or erosion causing a loss of protective coatings, deformation, or material loss. The South Texas Project has not experienced such containment conditions that would require augmented inspection.

NOC-AE-06001963 Page 6 of 30 4.3.2 Previous Integrated Leakage Rate Tests Results from previous Type A tests at the South Texas Project confirm that the reactor containment structure is extremely low leakage and represents minimal risk of increased leakage. Continued performance of Type B and Type C tests minimizes the risk for direct communication with containment atmosphere across containment penetrations.

To date, three Type A tests, preoperational and operational, have been performed on Unit 1, and two Type A tests, preoperational and operational, have been performed on Unit 2.

There is considerable margin between these Type A test results and the Technical Specification 3.6.1.2 limit of 0.75 La, where La is equal to 0.3% by weight of the' containment air per day at the peak accident pressure.

These test results demonstrate that leakage for both containment buildings is low. Two different testing methods were employed in performing these tests: the total time leakage rate method and the mass point leakage rate method. The results of both test methods are shown in Table 1 for the Type A tests conducted to date at the South Texas Project.

Note that the test results do not exceed the acceptance limit of 0.225 weight % per day (0.75 La) used by the South Texas Project.

4.3.3 Local Leak Rate Testing The existing Appendix J Type B and Type C testing programs will not be modified by this amendment.

However, the South Texas Project has been exempted from special treatment 10CFR50 requirements (Reference 4) for low risk significant and non-risk significant components, including those for Appendix J Type C testing.

No credit is taken for the Type A test in determining the risk significance of the excluded components. Type B and Type C tests of components not included in the exemption from 10 CFR 50 are performed in accordance with Appendix J and the associated Technical Specifications.

A leakage rate determined by integrated leakage rate tests is the total of containment leakage and Type B and C test results. Penetrations exempted from Type C Appendix J testing are assigned a leak rate value of 'zero' although some leakage is permitted.

Treating the previous results of these Type C test as 'zero' artificially increases the assigned containment leakage rate to compensate. Consequently, the Type A leakage is actually lower than that reported.

4.4 Maintenance Rule 10 CFR 50.65(a)(1) requires, in part, that the holders of an operating license monitor the performance or condition of structures, systems, or components, as defined in 10 CFR 50.65(b), against licensee-established goals, in a manner sufficient to provide reasonable assurance that such structures, systems, or components are capable of fulfilling their intended functions. Appropriate corrective action shall be taken when the performance or condition of a structure, system, or component does not meet established goals.

Maintenance Rule baseline inspections were performed in March 1998. The inspection results indicate that the program meets the requirements of 1 OCFR50.65, "Requirements for Monitoring the Effectiveness of Maintenance at Nuclear Power Plants" [the Maintenance Rule].

The inspection determined that the program for monitoring the condition and effectiveness of structures is appropriate and meets the intent of the Maintenance Rule. The results of the inspection are documented in NRC Inspection Report 50-498/98-01; 50-499/98-01, dated June 16, 1998.

NOC-AE-06001963 Page 7 of 30 4.5 Defense-in-Depth Defense-in-depth is maintained by the robust containment design (which is not affected by the proposed change), on-going performance monitoring, and inspection activities.

The proposed change only affects the inspection interval and has no effect on containment design margins or isolation system capability.

On-going performance monitoring and inspection is described in Section 4:3.

Calculations of radionuclide release do not consider re-establishment of containment cooling following core damage.

Re-establishing containment cooling would both decrease the actual release rate and scrub fission products from the containment atmosphere.

4.6 Industry Operating Experience The South Texas Project has in place a group tasked with review and assessment of documentation of events that have occurred at other nuclear power plants.

Documentation of industry events issued by the Institute for Nuclear Operations and the Nuclear Regulatory Commission is included under this program. Type A, Type B, and Type C test and maintenance programs at the South Texas Project can be modified as necessary to implement changes resulting from reported industry experience.

4.7 Risk Assessment 4.7.1

Background

The South Texas Project Probabilistic Risk Assessment (PRA) is a full scope Level 2 analysis of Core Damage Frequency (CDF) and Containment Response including Large Early Release Frequency (LERF) and Small Early Release Frequency. The STP PRA satisfies current industry PRA standards (ASME RA-Sa-2003) and generally meets these requirements at a capability category 2 rating.

The scope of STP's PRA is sufficient for assessing the risk impact of extending the Type A test interval; LERF is the key figure-of-merit relative to containment performance under severe accidents. STP does not have a Level 3 Probabilistic Safety Assessment and therefore does not have plant-specific information on the population dose associated with the various EPRI accident classes. Consequently, dose analyses are determined from estimates from NUREG-1 150.

A template approach developed by the Nuclear Energy Institute (NEI), as documented in NEI correspondence dated November 13, 2001, was originally used to extend the test interval for the Type A test from 10 years to 15 years. This application presents the results of using South Texas Project Level 2 PRA results for the proposed five-year test interval extension from 15 years to 20 years.

Containment failure sequences in the South Texas Project PRA leading to radiation release are classified across six major categories. These categories are defined in Table 3 of this report.

Included in Table 3 are the frequencies for these release categories as determined in the South Texas Project PRA.

4.7.2 NUREG-1493 Determination of risk associated with containment leakage and extended inspection intervals is addressed by NUREG-1493, "Performance-Based Containment Leak-Test Program." NUREG-1493 includes the results of a sensitivity study performed to explore the risk impact of several alternate leak-rate test schedules. Alternative 6 from this study examined relaxing the Integrated Leakage Rate Test frequency from 3 in 10 years to 1 in NOC-AE-06001963 Page 8 of 30 20 years.

NUREG-1493 concludes that the' increased risk of population dose attributable to extending the test interval to 20 years would be imperceptible.

The estimated increase in risk is small because Type A tests identify only a few potential leakage paths that cannot otherwise be identified by Type B and C testing. Using best estimate data, NUREG-1493 concludes that the increase in population exposure risk to those in the vicinity of the five representative plants ranges from 0.02 to 0.16 %. This low impact on risk is attributable to:

" Effectiveness of Type B and C tests in identifying potential leak paths; Low likelihood of ILRT-identified leakage exceeding twice the allowable; and

" Insensitivity of risk to containment leak rate.

Given the insensitivity of population risk to containment leakage rates, and the small fraction of overall leakage that can be detected solely by Type A tests, the interval between integrated leakage rate tests can be increased without adverse effect on public risk.

4.7.3 Accident Classification Accidents are classified according to the EPRI methodology for use in the ILRT evaluation:

  • Class 1 Sequence:

All core damage accident progression bins are included for which the containment remains intact with negligible leakage.

Containment isolation is successful, and long-term containment heat removal capability is available via containment sprays or fan coolers.

" Class 2 Sequence:

All core damage accident progression bins are included for which a pre-existing leak is present due to failure to isolate the containment.

These sequences are dominated by failure to close containment isolation valves that are greater than 2 inches in diameter.

" Class 3 Sequence:

All core damage accident progression bins are included for which there is pre-existing leakage in the containment structure that exceeds normal leakage. These are then grouped into two categories of leakage: small (3A) and large (3B).

  • Class 4 Sequence:

All core damage accident progression bins are included for which a failure-to-seal containment isolation failure occurs for Type B test components. This failure is detected by Type B tests, and their frequency of

.occurrence is very low compared with the other classes. No further separate evaluation will be performed.

  • Class 5 Sequence:

All core damage accident progression bins are included for which a failure-to-seal containment isolation failure occurs for Type C test components. This failure is detected by Type C tests, and their frequency of occurrence is very low compared with the other classes. No further separate evaluation will be performed.

" Class 6 Sequence:

All core damage accident progression bins are included for which a failure-to-seal containment leakage occurs due to failure to isolate the containment. This group is similar to Class 2. This sequence is dominated by misalignment of containment isolation valves following a test/maintenance activity. This is typically failure to close a smaller containment isolation valve.

NOC-AE-06001963 Page 9 of 30

" Class 7 Sequence:

All core damage accident progression bins are included for which containment failure occurs due to severe accident phenomena.

The containment bypass contribution is determined by each plant's PRA.

Class 8 Sequence:

All core damage accident progression bins are included for containment bypass occurrences.

Table 2 provides a summary description of the accident classes as well as correlation of the equivalent STP major release categories to the applicable EPRI accident class number. Note that only accident classes 3A and 3B are affected by changes in Type A test frequency.

4.7.4 Large and Small Early Release Frequencies Large Early Release Frequency (LERF) is defined in the PSA Applications Guide (reference 7) as the exchange of a single containment volume before effective implementation of the offsite emergency response and public protective actions. In turn, public protective actions are generally assumed to be taken 2 to 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> following a core damage event.

Given the response measures in place after 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />, dose consequences of the release are assumed to terminate after 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />, instead of extending the full 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> used to establish the rate of the release. Exchange of a single containment volume within four hours corresponds to the equivalent of six full exchanges (600%) of the containment volume in 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. The South Texas Project has a Type A test acceptance criterion of 0.225% per day. Conservatively setting the ILRT acceptance criterion at 0.10% per day, the leakage rate becomes 6000 La per day, or 1000 La over four hours.

The potential for a Large Early Release lies in large containment isolation failures and phenomenological effects associated' with severe accidents.

The predominant mechanical contributor to the Large Early Release Frequency (LERF) is failure to isolate the large supplemental purge penetrations in the unlikely event that a containment atmosphere purge is in progress during the accident. This potential contributor would not be impacted by the proposed increased interval between tests.

Large pre-existing leaks in the reactor containment building are not modeled in the South Texas Project PRA. (See also the discussion in Section 4.2.3.)

The results show that the major contributors for LERF at STP, as well as at other pressurized water reactors, are dominated by sequences resulting from a phenomenon called Induced Steam Generator Tube Rupture. This occurs when the secondary side of the steam generators dries out after a core damage event while the primary side of the reactor coolant system remains intact at high pressure.

High temperature coolant circulates through the reactor coolant system, heating up the steam generator tubes to the point of failure. Core damage scenarios that involve loss of all station AC power (Station Blackout) are the primary cause of Induced Steam Generator Tube Rupture sequences. This pathway through the steam generators is not covered by the ILRT.

The Small Early Release Frequency represents the potential for a small pre-existing leak. A small containment leakage pathway present prior to core damage is the most important contributor to small early releases. The primary contribution is from station blackout scenarios, but a significant portion derives from pre-existing leaks in the containment building. The impact of this change in the test interval would be a negligible increase in the contribution for a Small Early Release Frequency.

NOC-AE-06001963 Page 10 of 30 4.7.5 Calculations 4.7.5.1 Assumptions

1) The risk associated with extending the ILRT interval has no impact on the core damage frequency of the plant.
2) The risk associated with extending the ILRT interval is affected only by the likelihood for pre-existing leaks in containment.

There is no impact on containment failure modes such as containment bypass due to interfacing system LOCA and SGTR events, and failure of containment isolation function.

3) EPRI Accident Classes 4, 5, and 6 are not affected by the change in the ILRT interval and are not included in this evaluation.
4) The probability of pre-existing leak in containment is a function of the time between the ILRTs.
5) The maximum containment leak rate for EPRI Class 1 sequences is La (Type A acceptable leakage) since a new Accident Class 3 has been included to account for increase leakage due to increase in Type A inspection interval.
6) The maximum containment leakage for Accident Class 3A is 25 La.
7) The maximum containment leakage for Accident Class 3B is 1000 La.
8) The population dose results from NUREG/CR-4551 for Zion (reference 6) are applicable to STP by scaling the parameter based on the thermal output of the plants and the plant-specific population densities in the surrounding areas of the plants.
9) The rate of occurrence of Type A leakage sources is constant.

4.7.5.2 Accident Class Frequency Class 1 These sequences apply to core damage events in which containment isolation is successful, and long term containment heat removal capability is available through containment spray or reactor containment fan coolers. The event frequency with an intact containment is based on the South Texas Project PRA.

Class 1 represents containment leakage less than La.

The frequencies of Class 1, Class 3A, and Class 3B comprise release category REL IV.

Therefore, the frequency for Class 1 events is related to the intact containment core damage frequency as follows:

(Frequency Class 1) = (REL IV) - (Freq Class 3A) - (Freq Class 3B)

For the South Texas Project, REL IV = 4.88E-06.

Frequencies of Class 3A and Class 3B are addressed under Class 3 below.

Class 2 The frequency of occurrence for a Class 2 event is determined from the South Texas Project PRA. The frequency is not affected by changes in the test interval. No further assessment is performed.

NOC-AE-06001963 Page 11 of 30 Class 3 This group is separated into Class 3A for small containment leaks, and Class 3B for large containment leaks. Their probabilities are based on data from industry Type A test data.

Probability Class 3A is the probability of small pre-existing containment leakage in excess of design allowable but less than 100 La. See Section 4.7.5.3.

Probability Class 3B is the probability of large pre-existing containment leakage exceeding 100 La. See Section 4.7.5.3.

Class 4 These failures are detected by Type B tests.

The frequency is very low and its contribution is insignificant relative to the other probabilities.

The frequency is not affected by changes in the test interval. No further assessment is performed.

Class 5 These failures are detected by Type C tests.

The frequency is very low and its contribution is insignificant relative to the other probabilities.

The frequency is not affected by changes in the test interval. No further assessment is performed.

Class 6 This is primarily misalignment of containment isolation valves following a test or maintenance. Other failures of this type are covered in Class 2. Probability for a Class 6 event is the probability of random failure of containment to isolate due to valve misalignment (failure modes not otherwise included in Class 2). The frequency is very low and its contribution is insignificant relative to the other probabilities. The frequency is not affected by changes in the test interval. No further assessment is performed.

Class 7 Containment failure can also occur as a result of severe accident phenomena. The frequency for this group is the sum of frequencies for accident sequences that lead to early containment failure and to late containment failure. The frequency is not affected by changes in the test interval. No further assessment is performed.

Class 8 The contribution from core damage sequences in which containment bypass occurs is determined using the plant-specific PRA. The frequency for this group is the sum of frequencies for interfacing loss of coolant accidents and for steam generator tube rupture with no isolation. The magnitude of a Class 8 release is also plant-specific and is expected to be much larger than a release from a leakage event. Class 8 releases are not affected by the condition of the containment structure. The frequency is not affected by changes in the test interval. No further assessment is performed.

4.7.5.3 Baseline Frequency Determination Baseline frequencies for the various accident classes were determined from the STP-specific PRA. These Values are listed under "Frequency" in Table 4. The leakage rates associated with EPRI Accident Classes 3A and 3B are taken from WCAP-15691, Revision 5 (Reference 1).

Class 3A releases are based on Type A test history which indicates that approximately 3% of leaks identified by Type A tests may not be detected by local leak rate tests.

NOC-AE-06001963 Page 12 of 30 Class 3A releases are conservatively estimated based on a leakage rate of 25 La. Class 3B release frequencies are approximated as containment leakage greater than 100 La.

In computing public dose, Class 3B radiological releases are conservatively based on leakage of 1000 La.

The probabilities for leakage for Class 3A and Class 3B are based on results from previous Type A tests.

For Class 3A, 5 tests out of 182 encountered containment leakage. Consequently, a mean estimate for the probability of leakage for Class 3A is given by:

Leakage Probability Class 3A = 5/182

= 2.75E-02 For Class 3B, there is no Type A test result that could be categorized as a large release (i.e., LERF). To estimate the leakage probability for Class 3B, Jeffery's non-informative prior distribution is applied. The leakage probability for Class 3B is given by:

Leakage Probability Class 3B = (n + A )/( N + B) n = the number of failure events (0)

N = the number of tests (182)

A = distribution parameter (0.5)

B = distribution parameter (1.0)

Leakage Probability Class 3B = 2.73E-03 The resulting frequency for small leaks is:

Frequency Class 3A = (Probability Class 3A) * (REL IV)

= (2.75E-02) * (4.88E-06)

= 1.34E-07 The resulting frequency for large leaks is:

Frequency Class 3B = (Probability Class 3B) * (REL IV)

= (2.73E-03) * (4.88E-06)

= 1.33E-08 Using these values, the adjusted frequency for a Class 1 leakage event is:

Frequency Class 1 (REL IV) - (Freq Class 3A) - (Freq Class 3B)

= 4.88E 1.34E 1.33E-08

= 4.73E-06 4.7.5.4 Effect on Frequency Calculating the impact of an extension assumes a constant rate of occurrence of Type A leakage points, and the potential for leakage is evenly distributed across the period of interest.

Relaxing the Type A test interval increases the average time that a leak detectable only by the Type A test can be present without having been detected. The increase is proportional to the increase in duration between containment tests. The historical data is based on tests performed three times in ten years.

Although this equates to a mean time between tests of 3.3 years (40 months), Type A tests are NOC-AE-06001963 Page 13 of 30 performed during refueling outages, which occur at 18-month intervals. Consequently, the test interval is assumed to be 3 years (36 months). Under Option B criteria, the test interval is 10 years, although currently the interval at the South Texas Project has a one-time extension out to 15 years.

Only Class 1, Class 3A, and Class 3B probabilities are affected by changes in the test interval. The increases in leak likelihood are directly proportional to the increase in time between Type A tests. Consequently, the factors for the various intervals are:

10 years:

120/36 = 3.33 15 years:

180/36 = 5.00 20 years:

240/36 = 6.67 The revised risk level is:

Revised Frequency = Baseline Frequency

  • Time Ratio For Class 3A as an example, the respective risk levels are:

10 years:

Revised Frequency = 1.34E-07

  • 3.33 = 4.46E-07 15 years:

Revised Frequency = 1.34E-07

  • 5.00 = 6.70E-07 20 years:

Revised Frequency = 1.34E-07

  • 6.67 = 8.94E-07 The calculated results for each accident class for each interval are given in Table 5. The baseline results are included for comparison.

4.7.5.5 Baseline Population Dose Rate Determination Because a Level 3 Probabilistic Safety Assessment has not been prepared for STP, STP-specific information on the population dose associated with the various accident classes is not available. The population dose for STP was estimated from the results given in NUREG/CR-4551 (reference 6) for Zion.

The population dose is weighted for each group by multiplying according to the frequency of the assigned accident class. The dose for each accident class is found by adding up the assigned frequency-weighted population dose contributions.

The corresponding population dose for STP for each of the accident classes (except 3A and 3B) is derived using a conversion factor based on the Zion and STP population demographics within a 50-mile radius and thermal power level of the plants.

The baseline doses for Accident Classes 3A and 3B are found by multiplying the Class 1 dose by the La for the associated accident class:

Class 3A dose = Class 1 dose

  • Class 3A leakage

= 1.57E+01

  • 25 La

= 3.93E+02 person-Rem Class 3B dose = Class 1 dose

  • Class 3B leakage

= 1.57E+01

  • 1000 La

= 1.57E+04 person-Rem For Class 3A as an 6xa mlle, the respective dose rate is:

NOC-AE-06001963 Page 14 of 30 Population Dose Rate = Class 3A Dose

  • Class 3A Frequency

= 3.93E+02

  • 1.34E-07

= 5.27E-05 person-rem/reactor-year The baseline population dose for each accident class is given in Table 4.

4.7.5.6 Effect on Population Dose Rate Population dose rate is the product of the dose associated with a given event class and the frequency at which it is expected to occur.

Dose Rate = Dose

  • Event Class Frequency For Class 3A as an example, the respective dose rates are:

10 years:

Population Dose Rate = 3.93E+02

  • 4.47E-07 = 1.76E-04 15 years:

Population Dose Rate = 3.93E+02

  • 6.71 E-07 = 2.63E-04 20 years:

Population Dose Rate = 3.93E+02

  • 8.95E-07 = 3.51 E-04 The change in population dose rate for a given frequency can be expressed as:

A Population Dose Rate = New Dose Rate - Baseline Dose Rate For Class 3A as an example, the respective changes in population dose rate (person-rem per reactor-year) are:

10 years:

A Population Dose Rate = 1.76E 5.27E-05 = 1.23E-04 15 years:

A Population Dose Rate = 2.63E 5.27E-05 = 2.1OE-04 20 years:

A Population Dose Rate = 3.51 E 5.27E-05 = 2.98E-04 The total frequency-weighted dose rate for a given interval is found by adding the results for each accident class. The results of calculations for each accident type for the various intervals are given in Table 5.

Included are assessments of the change from the baseline case in both real and relative terms. Note that changing the interval has no effect on dose rate for accident classes 2, 4, 5, 6, 7, and 8.

Table 5 shows the relative contribution of dose rate due. to ILRT-affected accident classes (1, 3A, and 3B) compared to the total population dose rate. The change in the percentage contribution for each Type A test interval is included.

4.7.5.7 Effect on Large Early Release Frequency (LERF)

Extending the Type A test interval may affect the risk that a core damage scenario, normally resulting in a small radioactive release from containment, could result in a large release due to an undetected leak path. Only Class 3 sequences (pre-existing leaks) have the potential to result in early releases. The frequencies of Class 3B sequences are used as a measure of LERF, and the change in LERF is determined by the change in Class 3B frequency. Therefore, the change in LERF is expressed as:

ALERF = (Frequency Class 3B) - (Frequency Class 3B baseline)

The baseline frequency for Class 3B events is 1.33E-08 as shown in 4.7.5.3. As the Type A test interval is extended, the probability for a large early release changes as follows:

NOC-AE-06001963 Page 15 of 30 10 years:

ALERF = 4.44E 1.33E-08 = 3.11E-08 15 years:

ALERF = 6.66E 1.33E-08 = 5.33E-08 20 years:

ALERF = 8.88E 1.33E-08 = 7.55E-08 Details are shown in Table 5.

4.7.5.8 Effect on Conditional Containment Failure Probability (CCFP)

CCFP is defined as the probability of containment failure given the occurrence of core damage. CCFP is calculated for a given Type A test interval by determining ;he ratio of probability of NO containment failure to the overall core damage frequency. CCFP is found for an interval by subtracting the calculated ratio from 1.0 (unity).

CCFP = 1 -(Frequency Class 1)/(Total CDF)

The baseline value is found using the baseline Class 1 frequency of 4.73E-6 and the total core damage frequency of 9.02E-06. The resulting baseline CCFP is 0.475.

CCFP is a measure of the likelihood of an intact containment being present at the time of an event. The likelihood decreases as the Type A test interval increases. The change from the baseline CCFP value for each extended Type A test interval is:

10 years:

ACCFP = [1 - 4.39E-06 / 9.02E-06] - 0.475 = 3.83E-02 15 years:

ACCFP = [1 - 4.14E-06 / 9.02E-06] - 0.475 = 6.60E-02 20 years:

ACCFP = [1 - 3.90E-06 I 9.02E-06] - 0.475 = 9.26E-02 Relative to the baseline CCFP of 0.475, the change in CCFP at 20 years is 19.5%. The progression of increase is nearly linear with the increasing interval. There is substantial margin remaining before the intact containment contribution to. containment failure probability is no longer significant.

Details are shown in Table 5.

4.7.5.9 Assessment of Containment Liner Corrosion Detectable Flaw Likelihood of a flaw developing in the containment liner as a result of corrosion is determined by dividing the number of observed flaws by the number of applicable plant years. The likelihood for occurrence of a liner flaw is determined by the following:

Containment Flaw Likelihood = (observed flaws) / (containment-years)

Over a period of 5.5 years following implementation of the containment inspection criteria beginning in 1996, visual inspection of 70 containment liners identified two instances of liner flaws. Consequently:

Containment Flaw Likelihood = 5.19E-03 (containment cylinder and dome)

This value is taken as the year 0, or base value for the South Texas Project. This result does not reflect differences that may result from the differing ages of the various plants reviewed. The South Texas Project is relatively young compared to other plants; consequently, this value is conservative for the South Texas Project.

Zero failures have been observed by the industry for the containment basemat area. To estimate the failure likelihood for this area, Jeffery's non-informative prior distribution is applied. The leakage likelihood is given by:

NOC-AE-06001963 Page 16 of 30 Basemat Leakage Likelihood = [(n + A) / (N + B)] / T n = the number of failure events (0)

N = the number of tests (70)

A = distribution parameter (0.5)

B = distribution parameter (1.0)

T = Elapsed Time (5.5 years)

Basemat Leakage Likelihood = 1.28E-03 For the 20-year interval, the number of observed flaws is assumed to double every five years.

Doubling every five years means an average annual increase in the failure occurrence of 14.9%.

This results in progressive increases in failure probability for the containment cylinder and dome sections and the containment basemat as follows:

CUMULATIVE FAILURE LIKELIHOOD INTERVAL DOME AND CYLINDER BASEMAT Start 5.19E-03 1.28E-03 3 years 9.05E-03 1.94E-03 5 years 1.04E-02 2.56E-03 10 years 2.08E-02 5.12E-03 15 years 4.15E-02 1.02E-02 20 years 8.30E-02 2.05E-02 The increase in flaw likelihood from 3 years to 20 years is the difference in the listed values. Consequently, for the dome and cylinder:

A Likelihood of detectable flaw = 8.30E 9.05E-03

= 7.40E-02 For the basemat:

A Likelihood of detectable flaw = 2.05E 1.94E-03

= 1.88E-02 Undetectable Flaw The increase in likelihood for non-detected, corrosion-induced containment leakage is the product of:

" The increase in flaw likelihood during the extended inspection interval; The likelihood of failure of visual inspection to detect the flaw; and

" The likelihood of a containment breach during a pressure increase given a liner flaw.

NOC-AE-06001963 Page 17 of 30 The increase in flaw likelihood was determined as above.

Previous instances of corrosion were discovered through visual inspection.

This evaluation assumes that for the cylinder and dome the probability of failure to detect an existing flaw is 10%. This includes 5% for failure to identify visible flaws and 5% to address non-visible flaws.

Non-visible flaws are those that have not completely penetrated through the containment dome/cylinder liner, but would be detected by a Type A test. For the containment basemat, the probability of failure to detect an existing flaw is 100%.

In determining the likelihood of a containment breach, the probability is assumed to increase logarithmically to 100% at the design pressure capacity of the containment, 141 psig (155.7 psia). The upper end pressure is consistent with the South Texas Project Level 2 PRA analysis. The likelihood for the lower end is assumed to be 0.1% at 5.3 psig (20 psia). Intermediate failure likelihoods are determined through logarithmic interpolation. The breach is assumed to occur at the Type A test pressure of 41.2 psig (55.9 psia), and the probability of failure at that pressure found through interpolation.

The likelihood values for the basemat are assumed to be one-tenth of those for the cylinder/dome analysis.

The change in likelihood is expressed as:

A Likelihood (Non-Detected) = F

  • V
  • B F = A Likelihood of detectable flaw V = Likelihood of failure of visual inspection to detect the flaw B = Likelihood of breach at ILRT pressure Using the change in the dome/cylinder value from 3 years to 20 years as an example:

F = 7.40E-02 V = 1.OOE-01 B = 6.5E-03 A Likelihood (Non-Detected) = 4.81 E-05 Similarly, for the basemat:

F = 1.88E-02 V = 1.OOE-00 B = 6.51E-04 A Likelihood (Non-Detected) = 1.22E-05 The total increase in likelihood is the sum of the calculated increase for the containment cylinder/dome and the basemat.

Likelihood (Non-Detected Leakage) = (Dome/Cylinder) + (Basemat) 10 years:

= 7.67E-06 + 2.07E-06 = 9.74E-06 15 years:

= 2.11 E-05 + 5.37E-06 = 2.65E-05 20 years:

2 a4.81 E-05 + 1.22E-05 = 6.03E-05 NOC-AE-06001963 Page 18 of 30 Table 6 presents the results of the analysis for the likelihood of non-detected containment leakage due to liner corrosion.

Results for 10 years and 15 years are included for comparison.

The risk from extending the Type A test interval from 3 in 10 years to one in 20 years is determined using the following considerations:

  • The risk associated with failure of the containment due to a pre-existing containment breach at the time of core damage (Class 3A and Class 3B).

" The risk associated with liner corrosion that could increase the likelihood a containment over-pressurization event becomes a large early release event.

The non-LERF containment over-pressurization failure frequency is the sum of frequencies for Class 1, Class 3A, and the late release contribution from Class 7 (REL II).

Non-LERF = (Freq Class 1) + (Freq Class 3A) + (Freq REL II) 10 years: Non-LERF = 4.39E-06 + 4.46E-07 + 1.38E-08 = 4.85E-06 15 years: Non-LERF = 4.14E-06 + 6.70E-07 + 1.38E-08 = 4.82E-06 20 years: Non-LERF = 3.90E-06 + 8.94E-07 + 1.38E-08 = 4.81 E-06 The increase in LERF due to corrosion-induced leakage becomes:

A LERF = (Likelihood Total Non-Detected) * (Non-LERF) 10 years: A LERF = 9.74E-06

  • 4.85E-06 = 4.73E-11 15 years: A LERF = 2.65E-05
  • 4.82E-06 = 1.28E-10 20 years: A LERF = 6.03E-05
  • 4.81 E-06 = 2.90E-10 EFFECT OF EXTENDING TYPE A TEST INTERVAL FROM 3 YEARS TO 20 YEARS Containment Change in Change in Liner Condition Large Early Release Frequency Person-rem per year Without Corrosion 8.88E 1.33E-08 = 7.55E-08 1.39E 2.09E-04 = 1.1 8E-03 With Corrosion 7.55E-08 + 2.90E-10 = 7.58E-08 1.18E-03 + 4.55E-06 = 1.18E-03 Detailed results are provided in Table 6.

4.7.6 Conclusion The effect of extending the Type A test interval to 20 years has been assessed in the areas of risk, population dose, large early release frequency, and conditional containment failure probability, with the addition implications of corrosion.

Although approved to follow a ten-year test interval, with the one-time use of 15 years currently in effect, this assessment takes the conservative approach of comparing the effects of the 20-year interval against those of the previous requirement of three tests in 10 years.

Using substantial conservatisms in the bases for the calculated values:

NOC-AE-06001963 Page 19 of 30 The calculated change in LERF as a result of the interval extension to 20 years, including the effects of postulated corrosion, is 7.58E-08. This compares to the 1.OE-07 used as the limit for significance of changes in risk. Changes less than 1.0E-7 are considered small per Regulatory Guide 1.174.

The calculated change in the population dose rate due to LERF as a result of the interval extension to 20 years, including the effects of postulated corrosion, is 1.1 8E-03 person-rem / reactor-year. This compares to the base case total dose rate of 1.42E-02. The relative increase from the base case total dose rate is 8.31%.

The calculated conditional containment failure probability as a result of the interval extension to 20 years increases from a probability of 0.475 to 0.567, a change of 9.26E-02, or 19.5%. While a failed containment concurrent with an event is more likely with a 20-year interval, the effect on the likelihood of an event, and on the consequences of an event, is insignificant.

The proposed changes will not alter assumptions relative to the mitigation of an accident or transient event, and will not adversely affect normal plant operation and testing. The proposed changes are consistent with the current safety analysis assumptions and with the Technical Specifications. The effects of lengthening the time between Type A tests are summarized in Table 5.

Overall plant risk due to containment leakage is relatively small, given the small probability of containment leakage itself. The predominant mechanical contributor to the Large Early Release Frequency is failure to isolate the large supplemental purge penetrations in the unlikely event that a purge is in progress during the accident. This contributor would not be impacted by this proposed change.

Test histories, structural capability of the containments, and risk assessments have established that:

Containment leakage rates are acceptable with considerable margin;

  • The structural integrity of containment is assured; and Risk impact in extending the Type A test interval to 20 years is negligible.

Postponement of Type A testing could increase the probability of occurrence of a small containment leak. This increased probability has been shown to result in a very small increase in the calculated population dose for the South Texas Project.

However, extension would not cause a significant change in risk, nor cause NRC safety goals to be exceeded.

5.0 REGULATORY ANALYSIS

5.1 No Significant Hazards Consideration The proposed Technical Specification revision extends the current interval for Type A testing. The current test interval would be extended on a one-time basis to 20 years from the preceding Type A test. Pursuant to 10CFR50.91, this analysis provides a determination that the proposed change to the Technical Specifications for a one-time extension of the interval for Integrated Leakage Rate Testing does not involve any significant hazards consideration as defined in 10CFR50.92.

NOC-AE-06001963 Page 20 of 30 The proposed change does not involve a significant increase in the probability or consequences of an accident previously evaluated.

The proposed extension to the Type A test interval will not increase the probability of an accident previously evaluated.

The Type A test interval extension is not a modification and the test interval extension is not of a type that could lead to equipment failure or accident initiation.

NUREG-1493 concluded that reducing the Type A test frequency to one per twenty years leads to a small increase in risk. Testing and inspection provide a high degree of assurance that the containment will not degrade in a manner detectable only by Type A testing.

Previous Type A tests at the South Texas Project demonstrate leakage does not exceed acceptance criteria, indicating a very leak-tight containment. Inspections required by the Maintenance Rule and ASME code are expected to identify indications of containment degradation that could affect leak tightness. The on-going need for pressure relief by periodic venting through the supplementary purge system confirms that containment integrity continues.

Consequently, extending the Type A test interval to 20 years does not involve a significant increase in the probability of occurrence or consequences of an accident.

" The proposed change does not create the possibility of a new or different kind of accident from any previously evaluated.

The proposed extension of the Type A test interval will not create the possibility of a new or different type of accident from any previously evaluated.

There are no physical changes being made to the plant and there are no changes in operation of the plant that could introduce a new failure mode, result in an accident, or affect mitigation of an accident.

  • The proposed change does not involve a significant reduction in the margin of safety.

The proposed extension of the Type A testing interval will not significantly reduce the margin of safety. The NUREG-1493 generic study of the effects of extending containment leakage testing found that a 20-year interval in Type A leakage testing results in an imperceptible increase in risk to the public. NUREG-1493 found that, generically, the design containment leakage rate contributes about 0.1 percent to the individual risk and that the increase in Type A test interval would have a minimal effect on this risk because 95% of the potential leakage paths are detected by Type B and C testing. The increase in LERF has been found to be less than 1.OE-07.

Deferral of Type A testing for the South Texas Project does not increase the level of public risk due to loss of capability to detect and measure containment leakage or loss of containment structural capability. Other containment testing methods and inspections will assure all limiting conditions of operation will continue to be met.

The potential for development of corrosion during the extended interval, but was determined to have an insignificant impact. The margin of safety inherent in existing accident analyses is maintained.

Based on the evaluation provided above, the South Texas Project concludes that the proposed change does not involve a significant hazards consideration and will not have a significant effect on safe operation of the plant.

Therefore, there is reasonable assurance that operation of the South Texas Project in accordance with the proposed revision to the Technical Specifications will not endanger the public health and safety.

NOC-AE-06001963 Page 21 of 30 5.2 Applicable Requirements 10 CFR 50, Appendix J, "Primary Reactor Containment Leakage Testing for Water-Cooled Power Reactors" Regulatory Guide 1.163, "Performance-Based Containment Leak-Test Program" 5.3 Analysis The testing requirements of 10CFR50, Appendix J, provide assurance that containment leak paths, including systems and components that penetrate the containment, do not exceed the allowable leakage values specified in the Technical Specifications.

Effective October 26, 1995, 10CFR50, Appendix J, was revised to allow licensees to choose containment leakage testing under Option A, "Prescriptive Requirements," or Option B, "Performance-Based Requirements." The South Texas Project complies with the criteria of Option B - Performance-Based Requirements. Adoption of the Option B performance-based containment leakage rate testing program did not alter the basic method by which Appendix J leakage rate testing is performed; however, it did alter the frequency of measuring primary containment leakage in Type A, B, and C tests.

Regulatory Guide 1.163 endorses NEI 94-01, Revision 0, "Industry Guideline for Implementing Performance-Based Option of 10 CFR 50, Appendix J," dated July 26, 1995 and prepared by the Nuclear Energy Institute. Exceptions to the requirements of Regulatory Guide 1.163 are allowed by 10CFR50, Appendix J, Option B,Section V.B, "Implementation," which states:

The Regulatory Guide or other implementing document used by a licensee, or applicant for an operating

license, to develop a performance based leakage-testing program must be included, by general reference, in the plant technical specifications. The submittal for technical specification revisions must contain justification, including supporting analyses, if the licensee chooses to deviate from methods approved by the Commission and endorsed in a regulatory guide.

Consequently, extending the interval requires a license change only and not an exemption from Option B.

NEI 94-01 provides methods acceptable to the NRC staff for complying with the provisions of Option B as described in Regulatory Guide 1.163. NEI 94-01 Revision 0 includes the criterion that Option B Type A testing be performed at a frequency of once per 10 years based on an acceptable performance history (i.e., two consecutive periodic Type A tests at least 24 months apart where the calculated performance leakage rate was less than 1.0 La) and consideration of the performance factors in NEI 94-01, Section 11.3. The test frequency is based upon a generic evaluation documented in NUREG-1493 (Reference 3).

NUREG-1493 states that reducing the Type A (ILRT) test frequency to 1 per 20 years leads to an imperceptible increase in risk.

The estimated increase in risk is small because a Type A test will identify only a few potential leakage paths that cannot otherwise be identified by Type B and C testing. Given the insensitivity of population risk to containment leakage rates, and the same fraction of leakage detected solely by Type A tests, the interval between integrated leakage rate tests can be increased with negligible effect on public risk.

NOC-AE-06001963 Page 22 of 30

6.0 ENVIRONMENTAL CONSIDERATION

10 CFR 51.22(b) specifies the criteria for categorical exclusion from the requirements for a specific environmental assessment per 10 CFR 51.21. The South Texas Project has evaluated the proposed amendment and determined that:

" The proposed amendment does not involve a significant hazards consideration.

As demonstrated in the No Significant Hazards Consideration Determination, the requested license amendment does not involve any significant hazards consideration.

" There is no significant change in the types or significant increase in the amounts of any effluent that may be released offsite.

The proposed amendment involves no change to the facility and does not involve any change in the manner of operation of any plant systems involving the generation, collection or processing of radioactive materials or other types of effluents.

Therefore, no increase in the amounts of effluents or new types of effluents would be created.

There is no significant increase in individual or cumulative occupational radiation exposure.

The requested license amendment involves no change to the facility and will not increase the radiation dose resulting from the operation of any plant system.

Furthermore, implementation of this proposed change will not involve work activities that could contribute to occupational radiation exposure. Therefore, there will be no increase in individual or cumulative occupational radiation exposure associated with this proposed change.

Accordingly, the proposed amendment meets the eligibility criteria for categorical exclusion set forth in 10 CFR 51.22(c)(9). Therefore, pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment is required to be prepared in connection with these proposed changes.

7.0 IMPLEMENTATION The South Texas Project requests feedback from the Nuclear Regulatory Commission no later than May 31, 2006, as to whether the proposal is viable for approval to support the Unit 2 outage currently scheduled for March 2007.

Although this request is neither exigent nor an emergency, prompt review by the Nuclear Regulatory Commission is requested.

8.0 REFERENCES

1.

Regulatory Guide 1.163, "Performance-Based Containment Leak-Test Program,"

September 1995

2.

American National Standard ANSI/ANS - 56.8 - 1994, "Containment System Leakage Testing Requirements"

3.

NUREG-1493, "Performance-Based Containment Leak-Test Program"

4.

"Safety Evaluation on Exemption Requests from Special Treatment Requirements of 10 CFR Parts 21, 50, and 100 (TAC Nos. MA6057 and MA6058)," dated August 3, 2001 NOC-AE-06001963 Page 23 of 30

5.

WCAP-15691, "Joint Applications Report for Containment Integrated Leakage Rate Test Interval Extension," Revision 5 (March 2004)

6.

NUREG/CR-4551, Volume 7, Revision 1, "Evaluation of Severe Accident Risks:

Zion, Unit 1," March 1993

7.

"PSA Applications Guide," EPRI, Palo Alto, CA (1995) (TR 105396)

NOC-AE-06001963 Page 24 of 30 TABLE 1 PREVIOUS TEST RESULTS Unit Date Test Pressure Acceptance Mass Point Total Time (psig)

Limit (%)

Leakage (%)

Leakage (%)

03/25/87 37.4 0.225 0.0320 0.0321 1

01/10/91 39.5 0.225 0.0668 0.1336 03/10/95 44.5 0.225 0.020 0.0139 09/27/88 38.3 0.225 0.034 0.034 2

09/23/91 44.6 0.225 0.0765 0.0681 NOC-AE-06001963 Page 25 of 30 TABLE 2 ACCIDENT CLASS INFORMATION Class No.

Description STP Mapping Class 1 Containment intact REL IV (not affected by ILRT frequency)

Class 2 Large Containment Isolation failures REL I (not affected by ILRT frequency)

Class 3A Small pre-existing leak in containment structure or liner, identifiable by ILRT (affected by ILRT frequency)

Class 3B Large pre-existing leak in containment structure or liner, identifiable by ILRT (affected by ILRT frequency)

Class 4 Small Isolation Failure - failure to seal

- Type B test REL IIA (not affected by ILRT frequencies)

Class 5 Small Isolation Failure - failure to seal

- Type C test REL IIA (not affected by ILRT frequencies)

Containment Isolation Failure -

Class 6 dependent failures personnel errors REL IIA (not affected by ILRT frequency, low frequency)

Class 7 Severe accident phenomena induces failures - early and late containment failures (not affected by ILRT frequency)

REL IB, II and Ill Containment Bypass -

SGTR and Class 8 Containment Bypass - SGTR and ISLOCA (not affected by ILRT frequency)

NOC-AE-06001963 Page 26 of 30 TABLE 3 MAJOR RELEASE CATEGORIES Name Definition Frequency (per year)

REL I Large early failure of containment -

1.59E-09 Containment Isolation Failure REL IA Large early failure of containment -

4.81 E-07 ISGTR and ISLOCA REL IB Large early failure of containment -

2.99E-08 Due to Severe Accident Phenomenon REL II Small early failure of containment 1.38E-08 REL IIA Small early failure of containment -

1.43E-06 Containment Isolation Failure REL III Late failure of containment -

2.18E-06 Due to Severe Accident Phenomenon REL IV No containment failure 4.88E-06 Total (Frequency per year) 9.02E-06 NOC-AE-06001963 Page 27 of 30 TABLE 4 BASELINE ACCIDENT CLASS INFORMATION Class No.

Description STP Mapping Frequency Leakage Population Dose, Population Dose Rate, person-rem person-rem/Rx-Year Class 1 No Containment Failure REL IV 4.73E-6 La 1.57E+01 7.43E-05 (not affected by changes to ILRT frequencies)

(REL IV Freq)

Value from Zion Dosel

  • Frequencyl minus (F3A + F3B)

Class 2 Large Containment Isolation Failures (failure-to-close)

REL I 1.59E-09 Value from Plant 1.61E+02 2.56E-7 (not affected by changes to ILRT frequencies)

Value from Plant PRA Value from Zion Dose2

  • Frequency2 PRA Class 3A Small Pre-existing Containment Leak 1.34E-07 25 La 3.93E+02 5.27E-05 (identifiable by ILRT; affected by ILRT frequency) 0.0275" (Class 1 dose for La) Dose3A* Frequency3A (REL IV Freq) 25 La Class 3B Large Pre-existing Containment Leak 1.33E-08 1000 La 1.57E+04 2.09E-04 (identifiable by ILRT; affected by ILRT frequency) 0.00273*

(Class 1 dose for La) Dose3B

  • Frequency3B (REL IV Freq)
  • 1000 La Class 4 Small Isolation Failure (failure-to-seal) (Type 8)

NA NA NA (not affected by ILRT frequencies)

Class 5 Small Isolation Failure (failure-to-seal) (Type C) 1.432-08 NA NA NA (not affected by ILRT frequencies)

Value from Plant PRA Class 6 Containment Isolation Failures NA NA NA (affected by ILRT frequency, low probability)

Class 7 Severe Accident Phenomena REL lB, II, and III 2.22E-06 Value from Plant 5.90E+03 1.31 E-02 (not affected by ILRT frequency)

Value from Plant PRA Value from Zion Dose7' Frequency7 I

PRA Class 8 Containment Bypassed REL IA 4.81E-07 Value from Plant 1.57E+03 7.55E-04 (not affected by ILRT frequency)

Value from Plant PRA Value from Zion Dose8

  • Frequency8 PRA Total CDF 9.02E-06 Total Dose Rate 1.42E-02 NOC-AE-06001963 Page 28 of 30 TABLE 5 EFFECTS OF INTERVAL CHANGE ON EVENT FREQUENCY AND POPULATION DOSE RATE Base Case (3 in 10 years) 10-Year Interval 15-Year Interval 20-Year Interval Class Population Dose**

Event Population Event Population Event Population Event Population Frequency Dose Rate***

Frequency Dose Rate***

Frequency Dose Rate***

Frequency Dose Rate***

1 1.57E+01 4.73E-06 7.43E-05 4.39E-06 6.89E-05 4.14E-06 6.50E-05 3.90E-06 6.12E-05 2

1.61 E+02 1.59E-09 2.56E-07 1.59E-09 2.56E-07 1.59E-09 2.56E-07 1.59E-09 2.56E-07 3A 3.93E+02 1.34E-07 5.27E-05 4.47E-07 1.76E-04 6.71E-07 2.63E-04 8.95E-07 3.51E-04 3B 1.57E+04 1.33E-08 2.09E-04 4.44E-08 6.79E-04 6.66E-08 1.05E-03 8.88E-08 1.39E-03 4

NA NA NA NA NA 5

NA 1.43E-06 NA 1.43E-06 NA 1.43E-06 NA 1.43E-06 NA 6

NA NA NA NA NA 7

5.90E+03 2.22E-06 1.31 E-02 2.22E-06 1.31E-02 2.22E-06 1.31E-02 2.22E-06 1.31E-02 8

1.57E+03 4.81E-07 7.55E-04 4.81E-07 7.55E-04 4.81E-07 7.55E-04 4.81E-07 7.55E-04 Total CDF Total Dose Rate 9.02E-06 1.42E-02 9.02E-06 1.48E-02 9.02E-06 1.52E-02 9.02E-06 1.57E-02 Change in Total Dose Rate from Base (rem) 6.06E-04 1.04E-03 1.47E-03 ILRT Fractional Contribution to Total Dose Rate 2.37E-02 6.36E-02 9.01E-02 1.15E-01 Change in ILRT Contribution to Total Dose Rate.9065-02 9.16E-02 LERF [Class 3B only]

1.33E-08 4.44E-08 6.66E-08 8.88E-08 Change in LERF from base 3.11E-08 5.33E-08 7.55E-08 Conditional Containment Failure Probability 0.475 0.513 0.541 0.568 Change in CCFP** from base 0.0382 0.0654 0.0927

  • This value is the change in the fraction of the total dose attributable to Classes 3A and 3B (those accident classes affected by change in ILRT surveillance interval) from the base dose.
    • Person-remn
      • Person-rem / Reactor-year NOC-AE-06001963 Page 29 of 30 TABLE 6 LINER CORROSION CASE COMPARISON Step Description Containment Containment Cylinder and Dome Basemat 86%

14%

Historical Liner Flaw Likelihood Failure Data:

Events: 2 Events: 0 Success Data:

2/(70"5.5) = 5.19E-03 0.5/((70+1 )*5.5) = 1.28E-03 Based on results from periodic visual inspections of containment surfaces for 70 steel-lined Containments over a 5.5-year period.

2 Age-Adjusted Liner Flaw Year Failure Year Failure Rate Likelihood Rate During a 20-year interval, 3

9.05E-03 3

1.94E-03 the assumed failure rate doubles every five years 5

1.04E-02 5

2.56E-03 (increasing 14.9% per year).

10 2.08E-02 10 5.12E-03 15 4.15E-02 15 1.02E-02 20 8.30E-02 20 2.05E-02 3

Change in Flaw Likelihood Between 3 and 10 Years 1.18E-02 3.18E-03 Between 3 and 15 Years 3.25E-02 8.26E-03 Between 3 and 20 Years 7.40E-02 1.88E-02 Uses age-adjusted liner flaw likelihood (Step 2).

Assumes failure rate doubles every five years.

NOC-AE-06001963 Page 30 of 30 4

Likelihood of Breach in Containment Given Liner Flaw The upper end pressure is consistent with the South Texas Project Level 2 PRA analysis. The likelihood for the lower end is assumed to be 0.1%. Intermediate failure likelihoods are determined through logarithmic interpolation.

The likelihood values for the basemat are assumed to be one-tenth of those for the cylinder/dome analysis.

(Note 1)

Pressure (psig)

Likelihood of Breach Pressure (psig)

Likelihood of Breach

+

+

20 58.9 (ILRT) 100 120 150 0.1%

=0.65%

12%

34%

100 20 58.9 (ILRT) 100 120 150

.01%

=0.065%

1.2%

3.4%

10%

5 Likelihood of Visual 10%

100%

Inspection Detection 5%

failure to identify Basemat cannot be visually Failure visual flaws plus 5%

inspected.

likelihood that the flaw is not visible (not through-cylinder but could be detected by ILRT) 6 Change in Likelihood of Not Detecting Containment Leakage 3 Years to 10 Years 7.67E-06 2.07E-06 3 Years to 15 Years 2.11E-05 5.37E-06 3 Years to 20 Years 4.81 E-05 1.22E-05 Product of results from steps 3, 4, and 5 Note 1: From the STP IPE, the median failure pressure for hoop failure is 162.8 psig with a O3c (standard deviation for a log-normal distribution) of 0.14. The median failure pressure for liner tear is 112.8 psig with a Oc of 0.2.

ATTACHMENT 2 REACTOR CONTAINMENT DESIGN AND CONSTRUCTION NOC-AE-06001963 Page 1 of 1 REACTOR CONTAINMENT DESIGN AND CONSTRUCTION Each South Texas Project containment building is a fully continuous, steel-lined, post-tensioned, reinforced concrete structure consisting of a vertical cylinder with a hemispherical dome, supported on a flat foundation mat.

The cylinder and dome are post-tensioned with high-strength unbonded wire tendons. The dimensions of the containment are:

150-foot inside diameter 239-1/4-foot inside height to the top of the dome 4-foot cylinder wall thickness 3-foot dome thickness.

18-foot mat thickness.

The top of the foundation mat is 41-1/4 feet below grade.

The entire inside face of the containment is a continuous welded steel liner plate provided to limit release of radioactive material into the environment. The nominal thickness of the liner is 3/8-inch. A 3/8-inch-thick plate is used on top of the foundation mat and is covered with a 24-inch concrete fill slab.

Increased plate thickness up to two inches is provided around all penetrations and for the crane girder brackets.

An anchorage system is provided to prevent instability of the liner.

For the dome, the anchorage system consists of meridional structural tees,,circumferential angles, and plates. A system of vertical and circumferential stiffeners is provided for the cylinder, using structural angles, channels, and plates.

Leak chase channels and angles are provided at the bottom liner seams which, after construction, are inaccessible for leak tightness examination due to the two-foot interior fill slab.

The cylindrical wall is reinforced with conventional steel reinforcing bars throughout the structure. The bars are placed in a horizontal and vertical pattern in each face of the cylinder wall. Additional bars are provided around penetrations and in the buttresses to resist local stress concentrations. Radial shear reinforcement is provided throughout, and tangential shear reinforcement is provided where required.

Reinforcement in the dome is provided in a meridional and circumferential pattern up to 45 degrees from the spring line, with the remaining area reinforced using a grid pattern. Reinforcement is provided on both faces of the dome wall.

Radial ties are provided both to resist radial shear and prevent de-lamination of the dome under pre-stressing.

The cylindrical portion and the hemispherical dome of the Containment are pre-stressed by a post-tensioning system consisting of horizontal and vertical tendons. Three buttresses equally spaced around the Containment provide anchor points for the horizontal tendons. The cylinder and the lower half of the dome are pre-stressed by horizontal tendons anchored 360 degrees apart, bypassing the intermediate buttresses. Each successive hoop is progressively offset 120 degrees from the one beneath it. The vertical U-shaped tendons are continuous over the dome, forming a two-way post-tensioning system for the dome. These tendons are anchored in a continuous gallery beneath the base slab which provides for installation and inspection of the vertical tendons.

The reinforced concrete containment structure is designed to resist loads imposed by external events such as wind, seismic activity, or tornado.

ATTACHMENT 3 APPLICATION OF REGULATORY GUIDE 1.174, "AN APPROACH FOR USING PROBABILISTIC RISK ASSESSMENT IN RISK-INFORMED DECISIONS ON PLANT-SPECIFIC CHANGES TO THE LICENSING BASIS" NOC-AE-06001963 Page 1 of 12 APPLICATION OF REGULATORY GUIDE 1.174, "AN APPROACH FOR USING PROBABILISTIC RISK ASSESSMENT IN RISK-INFORMED DECISIONS ON PLANT-SPECIFIC CHANGES TO THE LICENSING BASIS"

1.0 INTRODUCTION

The South Texas Project has completed a risk assessment of the proposed one-time extension of the containment Type A test interval to 20 years. The risk assessment follows the applicable guidelines of Regulatory Guide 1.174, "An Approach For Using Probabilistic Risk Assessment In Risk-Informed Decisions on Plant-Specific Changes to the Licensing Basis," on the use of Probabilistic Risk Assessment (PRA) findings and risk insights. The approach combined the Individual Plant Examination (IPE) results and findings to estimate plant risk on specific accident sequences impacted by Type A testing.

In implementing risk-informed decision-making, changes are expected to meet a key set of principles. These principles are:

Regulatory compliance; Defense-in-depth; Sufficient safety margins; Proposed increases in risk are small and their cumulative effects do not cause the NRC Safety Goals to be exceeded; and Performance-based implementation and monitoring strategies address uncertainties in analysis models and data and provide for timely feedback and corrective action.

The change in plant risk was evaluated based on the changes in the predicted person-rem/year frequency and Large Early Release Frequency (LERF).

The analysis examined plant-specific accident sequences in which the containment remains intact or the containment integrity is impaired. Specifically, the following were considered:

Core damage sequences in which the containment remains intact initially and in the long term (Class 1 sequences).

Core damage sequences in which containment integrity is impaired due to random isolation failures of plant components other than those associated with Type B or Type C test components; e.g., liner breach, or steam generator manway leakage (Class 3 sequences).

Core damage sequences in which containment integrity is impaired due to containment isolation failures of pathways left open following a maintenance test; e.g., valve failing to close following a valve stroke test (Class 6 sequences).

Accident sequences involving containment failure induced by severe accident phenomena (Class 7 sequences), containment bypass (Class 8 sequences),

large containment isolation failures (Class 2 sequences) and small containment isolation 'failure-to-seal' events (Class 4 and 5 sequences) are not included in this evaluation. These sequences are impacted by changes in Type B and C test intervals, not changes in the Type A test interval.

NOC-AE-06001963 Page 2 of 12 The steps taken to perform this risk assessment evaluation are as follows:

Quantification of the base-lined risk in terms of frequency per reactor-year for each of the eight accident classes presented.

Development of plant-specific person-rem dose (population dose) per reactor-year for each of the eight accident classes.

Evaluation of the risk impact of extending the Type A test interval one time to 20 years.

Determination of the change in risk in terms of LERF in accordance with Regulatory Guide 1.174.

2.0 SUBMITTAL CONTENT The following is provided as confirmation that the proposed licensing basis change is consistent with the key principles of risk-informed regulation in accordance with Regulatory Guide 1.174:

  • A description of how the proposed change will impact the current licensing basis.

See Attachment 1, Section 3.1.

" A description of the components and systems affected by the change, the types of proposed changes, the reason for the changes, and results and insights from an analysis of available data on equipment performance.

See Attachment 1, Sections 3.1, 3.2, and 4.7.

A tabulation of the current licensing basis accident parameters affected by the change and an assessment of the expected changes.

This change does not result in a change to the current licensing basis accident parameters.

  • A reevaluation of the licensing basis accident analysis and the provisions of 10 CFR Parts 20 and 100, if appropriate.

See Attachment 1, Section 4.7.5.

An evaluation of the impact of the change in licensing bases on the breadth or depth of defense-in-depth attributes of the plant.

See Attachment 1, Section 4.5.

Identification of how and where the proposed change will be documented as part of the plant's licensing basis (e.g., FSAR, TS, and license conditions).

See Attachment 1, Section 3.1 Section 2.2 of this attachment identifies assumptions developed to support this amendment request. No key assumptions (per RG 1.200T) were made in the PRA to perform this assessment.

  • Structures, systems, and components for which requirements should be increased.

Increased requirements are not necessary.

NOC-AE-06001963 Page 3 of 12 A description of the information to be provided as part of the plant's licensing basis (e.g., FSAR, TS, licensing condition).

See Attachment 1, Section 3.1.

The top events included in the STP Level 2 Containment Event Tree are presented in Table 1 of this attachment.

0 Components included in the STP PRA include all active components for the function modeled, and most passive components where failure could affect the system function. See Table 2 of this attachment.

A list of initiators considered and their frequencies, as well as the basis for excluding any initiators from the risk assessment.

See Attachment 1, Section 4.7.3.

A "Living PRA" program has been implemented at the South Texas Project to maintain the PRA in a state of readiness to provide a current, up-to-date assessment of the hardware and procedures that affect safety.

Procedures, guidelines, tools, and processes are put in place to allow the PRA to assess the current plant safety status.

The PRA is maintained by periodically updating it to reflect all relevant plant changes, new data, or improved understanding, thus monitoring over time the plant safety level and the relative importance of the various components supporting that level.

2.1 Appendix B The South Texas Project has developed a quality assurance plan for application to the PRA.

Included in the plan is provision for a qualified reviewer to perform technical reviews of PRA documents.

The reviewer checks the PRA document to assure technical adequacy of the work performed and to assure proper documentation.

Records of review comments and associated resolutions that are technical in nature and result in material changes to the PRA shall be maintained for the entire operating life of the plant.

2.2 Risk Assessment Methods The probabilistic safety assessment and its updates follow the procedures described in NUREG/CR-2300, "PRA Procedures Guide," January 1983, and approved plant procedures. NUREG-1150 identifies containment and severe accident issues, such as direct containment heating and induced steam generator rupture, that have been considered in the development and quantification of the containment event tree.

The analysis assumes:

The ILRT has no effect on the quantification of core damage frequency and large early release frequency.

The ILRT will only find "small holes" in containment, and therefore can be evaluated via Top Event 10 for small containment failure Level 2 analysis.

All other assumptions in STPRV42 are unaffected by this analysis and remain valid.

No credit is taken for operator action in the PRA model for releases from a failed containment. Associated risk is dominated by other event sequences which do require operator action.

NOC-AE-06001963 Page 4 of 12 Table 1: Model Name: STP RV42 Top Events for Event Tree: CET Top Event Description Name CDSQ TOGGLE FOR CORE DAMAGE SEQUENCES LBY BYPASS PRIOR TO VESSEL BREECH IS LARGE Li LARGE CONTAINMENT FAILURE PRIOR TO VESSEL BREECH LS INDUCED PORV LOCA PSC REACTOR COOLANT PUMP SEAL LOCA IS INDUCED STEAM GENERATOR TUBE RUPTURE IP INDUCED RCS HOT LEG OR SURGE LINE FAILURE BY CONTAINMENT BYPASSED PRIOR TO CORE DAMAGE

[1 CONTAINMENT FAIL PRIOR TO VESSEL BREECH CV CORE DAMAGE ARRESTED IN VESSEL R P RCS PRESSURE AT VESSEL BREACH AP ALPHA MODE FAILURE FOR CONTAINMENT HME HIGH PRESSURE MELT EJECTION (HPME)

C2 CONTAINMENT FAIL AT VESSEL BREECH L2 LARGE CONTAINMENT FAILURE AT VESSEL BREECH X2.

FAN COOLERS FAIL AT VESSEL BREECH DBC DEBRIS COOLED EX-VESSEL HE HYDROGEN BURN WITHIN 4 HOURS OF VESSEL BREECH CE CONTAINMENT FAILURE DUE TO EARLY BURN H3 LATE BURN OF COMBUSTIBLE GASES C3 LATE CONTAINMENT FAILURE DUE TO BURN XR FAN COOLERS FAIL AFTER LATE H2 BURN C4 CNTMT FAILURE DUE TO LONG TERM OVERPRESSURIZATION L4 LARGE LATE CONTAINMENT FAILURE NOC-AE-06001963 Page 5 of 12 Table 2: Model: STPRV42 Systems and Components System Top Event Name Description Major Components Class 1 E 120VAC INST 120V VITAL AC Instrument Inverter, distribution panel, regulating transformer, supply breakers Channel 1 AC1 INSTRUMENT CHANNEL I Channel 2 AC2 INSTRUMENT CHANNEL II Channel 3 AC3 INSTRUMENT CHANNEL Ill Channel 4 AC4 INSTRUMENT CHANNEL IV Class 1E 125VDC DA 125 VDC POWER TRAIN A - El All Battery, 2 battery chargers, distribution panels, supply breakers Class 1E 125VDC DB 125 VDC POWER TRAIN B - ElBtl Class 1E 125VDC DC 125 VDC POWER TRAIN C - El Cl 1 Class 1E 125VDC DD 125 VDC POWER TRAIN D - ElD1 1 Auxiliary Feedwa'ter AFWS AUXILIARY FEEDWATER SYSTEM Pump, flow control, isolation automatic valves, manual

.~,valves, AFWST, room cooling ýMD only)

Train A AFA AFW TRAIN A MD pump Train B AFB AFW TRAIN B MD pump Train C AFC AFW TRAIN C MD pump Train D AFD AFW TRAIN D TD pump, steam supply. No room cooling Component Cool ing Water CCWS COMPONENT COOLING WATER SYSTEM Pumps, heat exchangers, manual valvs in flow path, automatic valves with cooled system Train A KA CCW TRAIN A Train B KB CCW TRAIN B Train C KC COW TRAIN C CCW to Charging Pumps CHCL CCW COOLING TO CCPS MOVs, manual valves in flow path Train A CLA CCW COOLING TO CCP 1 A Train B CLB CCW COOLING TO CCP 1B CCW non-essential Isolation IN ISOLATION OF NON-ESSENTIAL CCW LOADS MOVs Containment Isolation Cl CONTAINMENT ISOLATION SYSTEM Active MOVs, AOVs, SOV, check valves.

Containment Purge Isolation CP CONTAINMENT SUPPLEMENTAL PURGE ISOLATION AOVs, MOVs Containment Event Tree AP ALPHA MODE FAILURE FOR CONTAINMENT Containment Event Tree BY CONTAINMENT BYPASSED PRIOR TO CORE DAMAGE Containment Event Tree Cl CONTAINMENT FAIL PRIOR TO VESSEL BREECH NOC-AE-06001963 Page 6 of 12 System Top Event Name Description Major Components Containment Event Tree C2 CONTAINMENT FAIL AT VESSEL BREECH Containment Event Tree C3 LATE CONTAINMENT FAILURE DUE TO BURN CNTMT FAILURE DUE TO LONG TERM Containment Event Tree 04 OEPESRZTO OVERPRESSURIZATION Containment Event Tree CDSQ TOGGLE FOR CORE DAMAGE SEQUENCES Containment Event Tree CE CONTAINMENT FAILURE DUE TO EARLY BURN Containment Event Tree CV CORE DAMAGE ARRESTED IN VESSEL Containment Event Tree DBC DEBRIS COOLED EX-VESSEL Containment Event Tree H3 LATE BURN OF COMBUSTIBLE GASES Containment Event Tree HE HYDROGEN BURN WITHIN 4 HOURS OF VESSEL BREECH Containment Event Tree HME HIGH PRESSURE MELT EJECTION (HPME)

Containment Event Tree IP INDUCED RCS HOT LEG OR SURGE LINE FAILURE Containment Event Tree IS INDUCED STEAM GENERATOR TUBE RUPTURE Containment Event Tree Li LARGE CONTAINMENT FAILURE PRIOR TO VESSEL BREECH Containment Event Tree L2 LARGE CONTAINMENT FAILURE AT VESSEL BREECH Containment Event Tree L4 LARGE LATE CONTAINMENT FAILURE Containment Event Tree LBY BYPASS PRIOR TO VESSEL BREECH IS LARGE Containment Event Tree LS INDUCED PORV LOCA Containment Event Tree PSC REACTOR COOLANT PUMP SEAL LOCA Containment Event Tree RP RCS PRESSURE AT VESSEL BREACH Containment Event Tree X2 FAN COOLERS FAIL AT VESSEL BREECH Containment Event Tree XR FAN COOLERS FAIL AFTER LATE H2 BURN Chemical and Volume Control CH CHEMICAL VOLUME AND CONTROL SYSTEM (CVCS)

Centrifugal charging pumps, room cooling, valves, Letdown Isolation LI CVCS LETDOWN AND SEAL RETURN LINES ISOLATION MOVs and AOV Letdown Isolation LO LETDOWN LINE AND CONTAINMENT ISOLATION MOVs Positive Displacement Pump PD POSITIVE DISPLACEMENT CHARGING PUMP PDP, TSC diesel and electric power distribution Essential Chilled Water ECHS ESSENTIAL CHILLED WATER SYSTEM Chillers, pumps, room cooling, manual valves in flow path Train A ECA ECH TRAIN A Train B ECB ECH TRAIN B Train C ECC ECH TRAIN C Essential Service Water ECWS ESSENTIAL COOLING WATER SYSTEM

  • Pumps, MOVs, strainers, traveling screens, room cooing Train AI WA ECW TRAIN A Train BI WB ECW TRAIN B NOC-AE-06001963 Page 7 of 12 System Top Event Name Description Major Components Train C WC ECW TRAIN C Emergency Transformer EX EMERGENCY TRANSFORMER FEEDS AN El BUS Transformer, breakers and bus to 1 E buses Standby Transformer SXA UNIT 1 STANDBY TRANSFORMER Transformer, breakers to 1 E buses Standby Transformer SXB UNIT 2 STANDBY TRANSFORMER (SHUTDOWN)

Transformer, breakers to 1 E buses Unit Auxiliary Transformer UA UNIT AUXILIARY TRANSFORMER Transformer, breakers to non-1 E standby buses 13.8kV Bus F BF 13.8 KV BUS 1F Standby bus to ElA 13.8kV Bus G BG 13.8 KV BUS 1G Standby bus to E1B 13.8kV Bus H BH 13.8 KV BUS 1H Standby bus to EIC Class 1E AC Power EP4KV ESSENTIAL 4160V BUSES ElA, E1B, ElC 416OVswitchgear, 480V load centers, 480V MCCs, breakers, transformers Train A EA 4.16 KV BUS ElA Train B EB 4.16 KV BUS E1B Train C EC 4.16 KV BUS E1C Offsite Grid OG LOOP AFTER START OF EVENT Data Offsite Grid OGR RECOVERY OF OFFSITE POWER WITHIN 1 HOUR Data Condensate CND CONDENSATE SYSTEM - POST TRIP Feedwater FWS MAIN FEEDWATER SYSTEM - ATWS Feedwater MFS MAIN FEEDWATER SYSTEM - POST TRIP EAB HVAC DM SMOKE PURGE DAMPERS Air-operated dampers EAB HVAC EABHV EAB HVAC SYSTEM FAILS Fans, dampers Train A FA EAB HVAC TRAIN A FANS Train B FB EAB HVAC TRAIN B FANS Train C FC EAB HVAC TRAIN C FANS Instrument Air IAS INSTRUMENT AIR SYSTEM Air compressors, driers, receivers.

Loss of DC Train A DCAIN 125 VDC POWER TRAIN A - ElAll INITIATOR Initiating Event Loss of DC Train B DCBIN 125 VDC POWER TRAIN B - El Bl1 INITIATOR Initiating Event Loss of CCW - 1 Train LCCWlA LOCCW - ABRUN, CCWB=F, CCWC=F Initiating Event Loss of CCW - 1 Train LCCWlB LOCCW - BCRUN, CCWA=F, CCWC=F Initiating Event Loss of CCW - 1.Train LCCW1C LOCCW - ACRUN, CCWA=F, CCWB=F Initiating Event Loss of CCW - 2 Trains LCCW2A LOCCW - ABRUN, CCWC=F Initiating Event Loss of CCW - 2 Trains LCCW2B LOCCW - BCRUN, CCWA=F Initiating Event Loss of CCW - 2 Trains LCCW2C LOCCW - ACRUN, CCWB=F Initiating Event Loss of CCW - 3 Trains LOCCWA LOSS OF CCW - BCRUN, ALL SUPPORT Initiating Event NOC-AE-06001963 Page 8 of 12 System Top Event Name Description Major Components Loss of CCW - 3,Trains LOCCWB LOSS OF CCW - ACRUN, ALL SUPPORT Initiating Event Loss of CCW - 3Trains LOCCWC LOSS OF CCW - ABRUN, ALL SUPPORT initiating Event Loss of CR HVAC - 1 Train LCRV1A LOCRV - ABRUN, CRVB=F, CRVC=F Initiating Event Loss of CR HVAC - 1 Train LCRV1B' LOCRV - BCRUN, CRVA=F, CRVC=F Initiating Event Loss of CR HVAC - 1 Train LCRVlC LOCRV - ACRUN, CRVA=F, CRVB=F Initiating Event Loss of CR HVAC - 2 Trains LCRV2A LOCRV - ABRUN, CRVC=F Initiating Event Loss of CR HVAC - 2 Trains LCRV2B LOCRV - BCRUN, CRVA=F Initiating Event Loss of CR HVAC - 2 Trains LCRV2C LOCRV - ACRUN, CRVB=F Initiating Event Loss of CR HVAC - 3 Trains LOCRVA LOSS OF CRE HVAC - BCRUN, ALL SUPPORT Initiating Event Loss of CR HVAC - 3 Trains LOCRVB LOSS OF CRE HVAC - ACRUN, ALL SUPPORT Initiating Event Loss of CR HVAC - 3 Trains LOCRVC LOSS OF CRE HVAC - ABRUN, ALL SUPPORT Initiating Event Loss of EAB HVAC - 1 Train LEABlA LOEAB - ABRUN, EABB=F EABC=F Initiating Event Loss of EAB HVAC - 1 Train LEAB1B LOEAB - BCRUN, EABA=F EABC=F Initiating Event Loss of EAB HVAC - 1 Train LEABlC LOEAB - ACRUN, EABA=F EABB=F Initiating Event Loss of EAB HVAC - 2 Trains LEAB2A LOEAB - ABRUN, EABC=F Initiating Event Loss of EAB HVAC - 2 Trains LEAB2B LOEAB - BCRUN, EABA=F Initiating Event Loss of EAB HVAC - 2 Trains LEAB2C LOEAB - BCRUN, EABB=F Initiating Event Loss of EAB HVAC - 3 Trains LOEABA LOSS OF EAB HVAC - BCRUN, ALL SUPPORT Initiating Event Loss of EAB HVAC - 3 Trains LOEABB LOSS OF EAB HVAC - ACRUN, ALL SUPPORT Initiating Event Loss of EAB HVAC - 3 Trains LOEABC LOSS OF EAB HVAC - ABRUN, ALL SUPPORT Initiating Event Loss of ECW - 1 'Train LECWlA LOECW - ABRUN, ECWB=F, ECWC=F Initiating Event Loss of ECW - 1 Train LECWlB LOECW - BCRUN, ECWA=F, ECWC=F Initiating Event Loss of ECW - 1 Train LECWlC LOECW - ACRUN, ECWA=F, ECWB=F Initiating Event Loss of ECW - 2,Trains LECW2A LOECW - ABRUN, ECWC=F Initiating Event Loss of ECW - 2.Trains LECW2B LOECW - BCRUN, ECWA=F Initiating Event Loss of ECW - 2,Trains LECW2C LOECW - ACRUN, ECWB=F Initiating Event Loss of ECW - 3,Trains LOECWA LOSS OF ECW - BCRUN, ALL SUPPORT Initiating Event Loss of ECW - 3Trains LOECWB LOSS OF ECW; ACRUN, ALL SUPPORT Initiating Event Loss of ECW -3 Trains LOECWC LOSS OF ECW - ABRUN, ALL SUPPORT Initiating Event ISLOCA VSEOS INTERFACING LOCA THROUGH SI MAINT GENST GENERIC PLANNED MAINTENANCE MAINT STATE MAINTENANCE STATES NOC-AE-06001963 Page 9 of 12 System Top Event Name Description Major Components MAINT TYPE TYPE OF QUANTIFICATION, AVG CDF OR MAINT MAPPNG 81 TOP EVENT FOR PDS BINNING MAPPNG BRKS STEAM LINE BREAK FRACTION MAPPNG Ni SUMP RECIRCULATION MAPPNG N2 EARLY CORE DAMAGE MAPPNG N3 ISOLATION OF SECONDARY SIDE MAPPNG N4 RECOVERABLE SGTR SEQUENCES MSS MSIV MAIN STEAM ISOLATION MSIVs, turbine trip, MS PORVs, MSSVs MSS PORV SG PORVS MSS S$

ONE OF FIVE SG SRVS OPERATES MSS S2 FOUR OR MORE SG SRVS MSS SL STEAM GENERATOR ISOLATION (SGTR)

MSS TURBINE TRIP FUNCTION Operator Actions!

OD OPERATOR DEPRESSURIZES RCS Operator Actions OF OPERATOR ACTION TO CONTROL MFW - POST TRIP Operator Actions, OL OPER DEPRESSURIZE BY BLOWING DOWN SGS Operator Actions1 OT MANUAL TRIP OF REACTOR Operator Actions OX OPERATOR ALIGNS EMERGENCY TRANSFORMER QPDS O

QOPS QDPS SYSTEM APCs, power supplies Train A QA QDPS TRAIN A Train B QB QDPS TRAIN B Train C QC QDPS TRAIN C Train D QD QDPS TRAIN D RCFC CF REACTOR CONTAINMENT FAN COOLERS Fans, dampers Trains A and B Run CFAB RCFCS - STATE ABRUN Trains A and C Run CFAC RCFCS - STATE ACRUN Trains B and C Run CFBC RCFCS - STATE BCRUN Reactor Coolant System OB OPERATOR ACTION FOR BLEED AND FEED Primary PORVs, MOVs Reactor Coolant System PO PRIMARY PRESSURE RELIEF Primary PORVs, MOVs, Pzr PSVs Reactor Coolant System PPVl ONE OF TWO PZR PORVS FAILED - ATWS Primary PORVs, MOVs, Pzr PSVs Reactor Coolant System PPV2 TWO OF TWO PZR PORVS FAILED - ATWS Primary PORVs, MOVs, Pzr PSVs Reactor Coolant System PR PRIMARY PRESSURE RELIEF (FAILS) OPEN Primary PORVs, MOVs, Pzr PSVs NOC-AE-06001963 Page 10 of 12 System Top Event Name Description Major Components Reactor Coolant System PSV1 ONE OR MORE PZR PSV FAIL - ATWS Pzr PSVs Reactor Coolant System PSV2 TWO OR MORE PZR PSV FAIL - ATWS Pzr PSVs Reactor Coolant System SE RCPS SEAL INJECTION AND BARRIER COOLING Movs, CVs, manual valves Reactor Coolant System SP PRESSURIZER SPRAY SOVs Reactor Coolant System VI VESSEL INTEGRITY Recovery Actions OM DIESEL GENERATOR RECOVERY FACTOR Recovery Actions OR OPERATOR STARTS TRAIN WITH NO SIGNAL Recovery Actions OS HVAC RECOVERY - START SMOKE PURGE Recovery Actions RE RECOVERY FACTORS BASED ON SPLIT FRACTIONS Recovery Actions REAF RECOVERY OF THE TURBINE DRIVEN AFW PUMP Recovery Actions RPDS RECOVERY OF PDS Pumps, heat exchangers, fow control valves, manual Residual Heat Removal OC RESIDUAL HEAT REMOVAL SYSTEM valves R

HPumps, heat exchangers, fow control valves, manual Residual Heat Removal FIX RHR SYSTEM HEAT EXCHANGERS valves Reactor Protecti6n System ESFAS ESF ACTUATION SYSTEM Master and slave relays Train A IA ESFAS ACTUATION TRAIN A Train B IB ESFAS ACTUATION TRAIN B Train C IC ESFAS ACTUATION TRAIN C Reactor Protection System SSPS SOLID STATE PROTECTION SYSTEM Input signals, logic, power supplies Train R SPR SSPS TRAIN R Train S SPS SSPS TRAIN S Reactor Protection System AM AMSAC AMSAC System Reactor Protection System RT REACTOR TRIP SYSTEM Breakers Reactor Protection System UET UNFAVORABLE EXPOSURE TIME - ATWS Standby Diesel Generator DGX STANDBY DIESEL GENERATOR SYSTEM Diesel generators and support equipment SDG 11 GA STANDBY DIESEL GENERATOR 11 SDG 12 GB STANDBY DIESEL GENERATOR 12 SDG 13 GC STANDBY DIESEL GENERATOR 13 SEISMC SAC SEISMIC FAILURE 4160 VAC POWER SEISMC SAF SEISMIC FAILURE OF AFW SEISMC SCL SEISMIC FAILURE OF ECH SEISMC SCW SEISMIC FAILURE OF CCW NOC-AE-06001963 Page 11 of 12 System Top Event Name Description Major Components SEISMC SDC SIESMIC FAILURE OF 125 VDC POWER SEISMC SDG SEISMIC FAILURE OF SDGS SEISMC SEW SEISMIC FAILURE OF ECW SEISMC SIV SEISMIC FAILURE OF INVERTERS/BATTERY CHARGERS SEISMC SOG SEISMIC FAILURE OF THE OFFSITE GRID SEISMC SSS SEISMIC FAILURE OF SSPS/ESFAS Spet Fuel Pool Cooling SFC SPENT FUEL POOL COOLING SFP Pumps, heat exchangers Accumulators Al ACCUMULATOR SAFETY INJECTION Accumulators, MOVs, CVs Safety Injection System HI HIGH HEAD SAFETY INJECTION SYSTEM Pumps, MOVs, CVs

- HHSI Train A HA HIGH HEAD SAFETY INJECTION TRAIN A HHSI Train B HB HIGH HEAD SAFETY INJECTION TRAIN B

'HHSI Train C HC HIGH HEAD SAFETY INJECTION TRAIN C Safety Injection System HLEG SI HOT LEG RECIRCULATION MOVs, CVs Safety Injection System LHSI LOW HEAD SAFETY INJECTION SYSTEM Pumps, MOVs, CVs, RHR heat exchanger (flow path)

LHSI Train A LA LOW HEAD SAFETY INJECTION TRAIN A

  • LHSI Train B LB LOW HEAD SAFETY INJECTION TRAIN B LHSI Train C LC LOW HEAD SAFETY INJECTION TRAIN C Safety Injection System SICOM SAFETY INJECTION COMMON RWST, common valves Train A PA SI COMMON TRAIN A Train MOVs, CVs, room coolers Train B PB SI COMMON TRAIN B Train MOVs, CVs, room coolers Train C PZ SI COMMON TRAIN C Train MOVs, CVs, room coolers Safety Injection System SIREC SI RECIRCULATION COMMON SYSTEM Signal, RWST Level transmitters Train A RA SI RECIRCULATION TRAIN A Sump Isolation MOVs, pump miniflow Ovs Train B RB SI RECIRCULATION TRAIN B Sump Isolation MOVs, pump miniflow Ovs Train C RC SI RECIRCULATION TRAIN C Sump Isolation MOVs, pump miniflow Ovs Safety Injection System S138 SI COLD LEG INJECTION PATH CHECK VALVES CVs Train A S138A S138 PATH A Train B S138B S138 PATH B Train C S138C S138 PATH C Containment Spray system CSR CONTAINMENT SPRAY - RECIRCULATION Pumps, MOVs, manual valves, CVs, nozzles Containment Spray system WI CONTAINMENT SPRAY - INJECTION Pumps, MOVs, manual valves, CVs, nozzles Fire Protection Pumps FPD Fire Protection Supply Pumps, FWSTs

ATTACHMENT 4 RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION (RAI)

REGARDING EPRI TECHNICAL REPORT 1009325, "RISK IMPACT ASSESSMENT OF EXTENDED INTEGRATED LEAK RATE TESTING INTERVALS" NOC-AE-06001963 Page 1 of 13 RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION (RAI)

REGARDING EPRI TECHNICAL REPORT 1009325, "RISK IMPACT ASSESSMENT OF EXTENDED INTEGRATED LEAK RATE TESTING INTERVALS" Please address the issuet described below associated with the determination of the probability for an extremely large leak. Provide the entire community uncertainty distribution for the probability, including the mean and 95th percentile values for this distribution.

Section 6.0: Issues associated with the determination of probability for an extremely large leak have been identified by NRC staff based on independent calculations using a methodology that addresses these issues and uses the estimates of the four experts from the report. Using an alternate methodology, the staff obtained a mean value of 8.8E-3 for the probability of an extremely large leak (A > 100 La) in a large containment.

Even though the staff estimate did not include the fatigue failure mode, the staff estimate is a factor of over 30 higher than the estimate given in the report (2.47E-4 from Table 6-1 of the EPRI report). Using the estimates of all six experts and including the fatigue failure mode may further increase the discrepancy between the estimate obtained and the estimate given in Table 6-1. The issues in the approach used in the EPRI report are described below:

a.

Since one leak size range for which expert opinion elicitation was performed was the extremely large leak size A > 100 La, the results of the expert elicitation should be used for that leak size only, instead of attempting a fit of the probability of a leak versus leak size to a Weibull distribution (Section 6.3). In other words, uncertainty distributions should be generated for the probability of the leak size range A > 100 La for each expert, and arithmetically average these uncertainty distributions. This becomes the community distribution, or aggregated distribution.

RESPONSE

The South Texas Project application does not use the expert elicitation approach.

Therefore, this request is not relevant to the South Texas Project application.

b.

The results for leaks greater than 100 La are based on a Weibull model (page 6-4). Because the Weibull is fitted to the estimated frequencies for small and medium leaks as well as large leaks, the estimated frequencies for large leaks are sensitive to the results for smaller leaks. In effect, the results for small and medium size leaks are extrapolated to large leaks. In view of the fact that there is no known relation between leak frequency and leak size, please provide the justification for using the Weibull distribution. In addition, use other distribution shapes to analyze the sensitivity of the results to the different distribution shapes.

RESPONSE

The South Texas Project application does not use the expert elicitation approach.

Therefore, this request is not relevant to the South Texas Project application.

c.

Each expert was asked to-provide his low, best, and high estimates (Sections 1 and 6. 2, pages 5-7 and 6-5). It is generally accepted that, in expert elicitation, the expert's "best estimate" refers to the median of the distribution. However, it is NOC-AE-06001963 Page 2 of 13 clear (page 6-5) that the expert's best estimate was treated as a mean. Please provide the guidance given to the experts as to the definition of the terms low, best and high estimates. Please describe the methods used to insure that the responses of the various experts had a common meaning. Please explain how the experts' inputs were interpreted in calculating the results.

RESPONSE

The South Texas Project application does not use the expert elicitation approach.

Therefore, this request is not relevant to the South Texas Project application.

d.

Tchebycheff's theorem (Section 6. 2, page 6-5) is used to derive a standard deviation from the low, best, and high estimates. However, even if the best estimate were the mean value, this theorem would give only a lower bound on the standard deviation. When Tchebycheff's theorem is used to estimate tail areas given the standard deviation, it is conservative, but when estimating the standard deviation given the tail areas, it is non-conservative. For example, for a normal distribution estimating the variance from the upper and lower 5 percent tails, the variance is estimated to be 0.27 times the true variance, and the estimated standard deviation is about half of the true standard deviation. Please justify the use of the Tchebycheff approximation.

RESPONSE

The South Texas Project application does not use the expert elicitation approach.

Therefore, this request is not relevant to the South Texas Project application.

e.

The EPRI report reduced the problem of fitting the probability of the leak rate size range to the leak rate to a linear regression problem. The estimates of the exceedance frequencies for the probabilities of leak rates of different sizes are dependent variables. The procedure of linearizing the problem requires approximations to be made in the treatment of the dependence of the variables.

Equations 6-19 (Section 6.3, page 6-7) are only valid if the errors in the Yi are linear functions of the errors in the Pk (i.e., it is assumed that a first order Taylor series expansion is an adequate approximation). These errors are in addition to the errors made by using Tchebycheff's theorem to estimate the variances of the Pk, and the errors made by assuming that the expert's best estimate is the mean of his uncertainty distribution.

RESPONSE

The South Texas Project application does not use the expert elicitation approach.

Therefore, this issue is not relevant to the South Texas Project application.

f.

A logit transformation of Q(a) is introduced, X=logit (Q), and X is assumed to be normally distributed (Section 6.3.4, page 6-8). It is difficult to see the justification for using a normal distribution for logit (Q). The minimization of D2, given in Equation 6-15 (Section 6.3.3, page 6-7) is consistent with assuming that the yJ have a joint normal distribution, with covariance matrix as given by Equation 6-

18. Then the most logically consistent approach would be to assume that the estimates bl, b2 of Equation 6-22 are jointly normally distributed, not that logit (Q) is normally distributed. Then ln(lnQ(a))is normally distributed. Please.

justify the assumption that Iogit(Q) is normally distributed.

NOC-AE-06001963 Page 3 of 13 Moreover, the uncertainty analysis approach is questionable because information on the uncertainty distributions for each expert are not included, except incorrectly by the use of Tchebycheff's theorem (Section 6, page 6-5, Equation 6-7). In addition, if the expert's best estimate corresponds, as is generally true, to the median and not mean, then the treatment of the best estimate as a mean is questionable.

RESPONSE

The South Texas Project application does not use the expert elicitation approach.

Therefore, this request is not relevant to the South Texas Project application.

g.

The EPRI report (Section 6. 6, page 6-10), notes that one expert used zero several times in the assignment of the probability of ILRT failure, and that zeros are difficult to treat in the statistical evaluation of expert opinion. This expert was not included in the community distribution, and therefore it was considered prudent to not include the highest expert as well. Although it seems that the expert who assigned zero to the probability of ILRT failure exhibited an extraordinary amount of overconfidence, there is no difficulty mathematically in including his results, when one uses only the estimates for the extremely large leak size range, and does not fit the probability of leak rates of different sizes to a Weibull distribution in the way done in the EPRI report. The reason for including this expert is that then there is no basis for discarding the estimates of the highest expert in the development of the community distribution.

Alternate Methodology: To eliminate these issues, the staff determined each expert's uncertainty distribution for the probability of an extremely large leak in the following way:

The expert's low, best estimate, and high probability estimates for the extremely large leak were fitted to a distribution, where the best estimate was taken as the median value of the distribution. A split lognormal distribution, truncated at the 99.9th percentile, was used and the remaining 0.1 percent of the distribution mass was placed at the 99.9th percentile. To define the bottom half of the distribution, the best estimate was used as the median value and the low estimate, treated as a 5 percent lower bound, was used for the second parameter defining the lognormal distribution. Similarly, the distribution for the upper part of the lognormal distribution was defined using the best estimate for the median value and the high estimate, treated as a 95 percent bound, was used for the other parameter. Then, the non-conservative errors from using the Tchebycheff distribution to estimate the variance are eliminated (Item d, above),

and the expert's best estimate is the median instead of the mean (Item g, above).

The low, best, and high estimates of the leak rate probability were given for only four experts, and the staff derived uncertainty distributions for only these four experts. The distributions for all six experts should be used (Item g, above).

The results were aggregated using Equation 6-29 of the EPRI report.

In principle, the issues in Section 6.3 of the EPRI report (Statistical Analysis of the Expert Elicitation Input) could be at least partially removed by using a non-linear least squares regression technique with a variety of functional forms of probability-of leak rate versus leak rate size.- Uncertainty distributions based on -

the split lognormal distribution with truncation could be used for the uncertainty in the expert's estimate of the leak rate of a specific size. However, when a variety NOC-AE-06001963 Page 4 of 13 of functional forms for the probability of leak rate vs. leak rate size are used, the uncertainties will likely be so large that there is no benefit from using this approach in comparison to the approach used by the staff (i.e., where the aggregate estimate of the probability of an extremely large leak is estimated by using only the experts estimates of the probability of an extremely large leak and no attempt is made to use a fit to a probability of leak rate vs leak rate size curve).

RESPONSE

The South Texas Project application does not use the expert elicitation approach.

Therefore, this request is not relevant to the South Texas Project application.

2.

Documentation is a key aspect of the expert elicitation process (per References 11 and 12 on EPRI report page 10-1). Only through documentation can the analysis and results be reviewed by others and provide a credible, defensible basis for the purposes of licensing. There is insufficient information provided in this report to conclude that the expert elicitation process is acceptable as conducted. As an example, the staff attempted to reproduce the EPRI results using the stated method in the report. The staff obtained different values in many cases. Please provide additional documentation regarding the basis for selection of the experts, the actual elicitation process, training provided to the experts, each individual expert's judgments and reasoning bases, and detailed calculations used to obtain the results documented in the report. (See Items 4, 5, 8, 10, 13, 18, 19, 32, and 33 below for additional details where documentation is requested.)

RESPONSE

The South Texas Project application does not use the expert elicitation approach.

Therefore, this request is not relevant to the South Texas Project application.

Report Summary

3.

Page v: The document is intended to be a demonstration that the "generic risk impact assessment for optimized ILRT intervals of up to 20 years" is very small for all containment designs and sites. However, the number of example calculations is very limited and biased and there is not enough evidence to support a conclusion that the assessments described are either representative or bounding for all designs and sites.

Provide additional justification and analyses to support a conclusion that the risk impact is very small for all containment types and sites.

RESPONSE

The risk impact assessment performed in support of this application is specific to the South Texas Project. Therefore, this request is not relevant to the South Texas Project application.

4.

Pages v and vi: It is stated that "there is a very small risk associated with the extension, provided that the performance bases and defense-in-depth are maintained." On page vi, it is stated that the expert panel also considered defense-in-depth approaches, such as alternative inspections that supplement the testing programs. Alternative means of leakage detection are briefly mentioned in Section 3.5, but do not appear to have been further pursued as part of-the risk study or expert elicitation process. Provide the -

following in this regard:

NOC-AE-06001963 Page 5 of 13 (1) A description of the performance bases and the defense-in-depth measures that are considered essential to assuring the very small risk associated with the extension; (2) Further details on the deliberations and conclusions of the expert panel in this area; and (3) An explanation of how safety principle 3 of Regulatory Guide 1.174 (related to the use of performance measurement strategies) would continue to be met if these bases/measures are not expected to be enhanced as part of the proposed extension of the ILRT interval (e.g., through use of indirect containment monitoring techniques or enhanced inspections as a condition of receiving the 20-year extension).

RESPONSE

(1) Performance bases are as described in Attachment 1, Section 4.3. Defense-in-depth against unidentified sources of containment leakage is addressed in Attachment 1, Section 4.5.

(2) The South Texas Project application does not use the expert elicitation approach.

Therefore, this request is not relevant to the South Texas Project application.

(3) Safety principle 3 of Regulatory Guide 1.174 ensures that a proposed change will maintain sufficient safety margins. Tests and inspections as adjuncts to the Type A tests to ensure performance requirements are satisfied are addressed in Attachment 1, Section 4.3.

Section 2: Problem Statement

5.

Section 2.2 (page 2-2): Please show the mathematical expressions for ALERF and A population-dose as a frequency-weighted sum over all accident classes rather than a simple product.

RESPONSE

Determination of ALERF is addressed in Attachment 1, Section 4.7.5.7.

Determination of A population dose rate is addressed in Attachment 1, Section 4.7.5.6.

6.

Section 2.2 (pacie 2-2): Footnote 1 defines an ILRT failure. A practical definition of ILRT failure is one which does not meet the Type A test performance criterion as defined in ANSI/ANS 56.2002. This definition should be used for risk-informed analysis. Please provide justification for using the less conservative definition of Footnote 1.

RESPONSE

The definition of "ILRT failure" provided in ANSI/ANS 56.8-2002, "Containment System Leakage Testing Requirements," is stated in Attachment 1, Section 4.1.

Section 3: ILRT Data Applicability

7.

Section 3 (page 3-1): The report states, "In fact, no failures that would result in a large early release have been found." There is no direct connection between ILRT failures and large early release. Early release is likely to occur under accident conditions which

- would generate high.pressures-or if the containment is not properly isolated. The ILRTs are performed at relatively low pressures and the duration of a test is articulated to NOC-AE-06001963 Page 6 of 13 ensure an essentially leak-tight containment. If ILRTs at DBA pressure indicate a leakage rate greater than 1 La to 10 La, it can be considered as a precursor to an early release under challenging accident pressures. (See Sandia Report SAND90-0119, "Insight into the Behavior of Nuclear Power Plant Containments During Severe Accidents.") This concept should be incorporated into the elicitation report.

RESPONSE

Results of previous Type A tests at the South Texas Project are addressed in, Section 4.3.2. There is no correlation made between ILRT failures and large early release. Large early release frequency is addressed in Section 4.7.4.

8.

Section 3 (page 3-1): The report states that "the testing data alone does not, without expert opinion, support the development of realistic values for the probability of a large containment leakage event."

a. Please explain why alternative statistical models beyond those identified in Table 3-1 can not be used to derive more realistic probability values (e.g., mean or 50 percentile values at some lower confidence level) in lieu of an expert elicitation process.
b. Also, provide a comparison of the probability values (for Class 3a and 3b leakage) obtained from the expert elicitation process with values derived from alternative statistical models or model assumptions (e.g., in the form of an expanded version of Table 3-1).

RESPONSE

a.

The South Texas Project application does not use the expert elicitation approach.

Therefore, this request is not relevant to the South Texas Project application.

b.

The South Texas Project application does not use the expert elicitation approach.

Therefore, this request is not relevant to the South Texas Project application.

9.

Section 3.1 (page 3-1): It is misleading to state: "The first ILRT survey was performed in early 1994-NUMARC/NEI," when NUREG/CR-4220 (June 1985): "Reliability Analysis of Containment Isolation System" provides an extensive database of isolation failures that occurred between 1965 and 1983 based on licensee event reports (LERs). NUREG-1273, "Technical Findings and Regulatory Analysis for GSI II.E.4.3, Containment Integrity Check," subsequently moderated the conservative bias of NUREG/CR-4220, and analyzed potential alternatives to ILRTs. Please provide justification for not using the combined database (old and new) and appropriate ILRT failure criterion (See Item 5) in the elicitation process and eventually in the risk-informed analysis.

RESPONSE

Test results from previous Type A tests at the South Texas Project are provided in, Section 4.3.2. Test data from other plants are not used in South Texas Project containment leak rate assessments. Therefore, this request is not relevant to the South Texas Project application.

Section 4: Expert Elicitation Process

10.

Section 4.1 (page 4-3), 4.4. and Table 4: Based on the credentials of the experts (Table o..

42 bf the-EPRIr~port),there Was onb expert irfprdba~bilistid risk as.essmenbt, thf6e in--

service inspection (ISI) and testing experts, and two containment leakage rate testing experts (one of which co-authored the report). Since most of the experts had little NOC-AE-06001963 Page 7 of 13 knowledge or experience in the field of containment leakage rate testing, training was provided during the meeting that may have influenced their proffered leakage rate probabilities. It is also stated (page 4-3) that "experts will be chosen for their knowledge of the mechanisms-that can result in containment leakage events, and therefore provide additional assurance that their judgment is only moderately significant to the overall result." Except for one expert from the NRC, the experts all have associations with industry rather than including experts from the National Laboratories or academic institutions. Please explain why there were not more containment leakage rate testing experts chosen for expert elicitation. Provide additional information and credentials to justify that the experts have expertise regarding the mechanisms that can result in containment leakage events (including relevant containment degradation mechanisms). Justify why the expert choices that were made would not lead to biased results, especially since the input from only four experts was used to determine the leakage rate probabilities.

RESPONSE

The South Texas Project application does not use the expert elicitation approach.

Therefore, this request is not relevant to the South Texas Project application.

11.

Section 4.3.2.1 (pagqe 4-3): The EPRI report notes that "the results of the expert elicitation process are very significant to the results of the analysis necessitating an assignment of a Degree II" importance (i.e., "highly contentious issue; very significant to the overall result of the analysis; and/or highly complex), but that this is mitigated by the availability of significant amounts of data. As a result, the issue was assigned a Degree II importance. Assigning the issue a Degree II importance appears to have enabled the use of a "technical integrator" approach, wherein the technical integrator plays the role of "evaluator." In contrast, assigning the issue a.Degree III importance would require the use of a "technical facilitator/integrator" approach, wherein multiple evaluators would be involved. One could argue the converse with regard to the availability of significant amounts of data, i.e., that there is insufficient data regarding large leakage events.

Please discuss the implications on the expert elicitation process and results if the issue were assigned a Degree III rather than Degree II degree of importance.

RESPONSE

The South Texas Project application does not use the expert elicitation approach.

Therefore, this request is not relevant to the South Texas Project application.

Section 5: Expert Elicitation Input

12.

Section 5.3 (pagqe 5-5): It is stated that the database of found degradations was included in the presentation, and that the effects of aging on potential containment failure modes was emphasized in the expert elicitation. Please provide a description of the technical content of the presentation, a copy of the slides/handouts from the meeting, and a characterization of the expert inputs regarding the significance of various degradation mechanisms to the probability of containment leakage derived from the expert elicitation process.

RESPONSE

The South Texas Project application does not use the expert elicitation approach, and was-n6ota pa.rticip.rift in-ih6 subj6cf p-r6cess.-The-r6fo-re, fhis r-equest is not relevant to the South Texas Project application.

NOC-AE-06001963 Page 8 of 13

13.

Section 5.5 (pages 5-6 and 5-7) and Section 6.2 (page 6-3): It is stated that the actual frequencies elicited from the experts were all relative to available data or to frequencies of smaller leaks. However, all of the results presented in the report are in terms of absolute frequencies. Please provide the raw elicitation inputs of the relative values provided by the experts. If "best," "low," and "high" relative values were elicited, please provide the guidance given to the experts as to the definition of these terms. Please describe how the relative values provided by the experts were used to calculate the absolute frequencies.

RESPONSE

The South Texas Project application does not use the expert elicitation approach.

Therefore, this request is not relevant to the South Texas Project application.

14.

Section 5.1 (page 5-7): Please explain why a multiplier of 2.5 (i.e., 10001400) was used rather than a multiplier of 5.5 (i.e., 1000 /182).

RESPONSE

The South Texas Project position is not dependent upon test results from other nuclear power plants. Use of a multiplier to normalize Type A test data from the industry in general is not necessary. Therefore, this request is not relevant to the South Texas Project application.

.Section 6: Expert Elicitation Results and Analysis

15.

Section 6.0 (and other sections): It is well-known that experts tend to underestimate the uncertainties of their subjective assessments. For example, a rule of thumb is that the actual coverage of an uncertainty interval is about a factor of two smaller than the nominal coverage. Thus, for almanac-type questions where the answers are known, only about half of the nominal 90% coverage intervals supplied by a panel of experts actually contain the correct answers. There is no discussion of this phenomenon in the report. Please explain why no adjustment was made to the expert responses to compensate for possible overconfidence.

RESPONSE

The South Texas Project application does not use the expert elicitation approach, and consequently is not influenced by subjective assessments of uncertainties. Therefore, this request is not relevant to the South Texas Project application.

16.

Section 6.1 (page 6-1): Separate input was collected for small containments and large containments. Please explain the decision for delineating based on containment size rather than containment type, especially since the applicability of various corrosion mechanisms or failure modes may be more a function of containment type than size. Please discuss the potential impact on results if the inputs were grouped based on containment type.

RESPONSE

The South Texas Project application is specific to its containment size and type.

Therefore, this request is not relevant to the South Texas Project application.

17.

Section 6.1 (page 6-2): The EPRI report states that "significant changes to failure modes were made by the-experts." It is hdt juitET dlear-Wvhibhfcilir *nddw-efe-nsidefed in '..

the expert elicitation process. One of the major failure modes that is relevant to the risk analysis is the corrosion of the bottom liner plate of concrete containments, and NOC-AE-06001963 Page 9 of 13 corrosion of the bottom head or plates of steel containments. These areas are not conducive to IS[ but an ILRT failure could indicate if any gross degradation is occurring.

The staff recognizes that no data is available to characterize the probability of such a failure. However, the elicitation process needs to consider the feasibility of such a failure mode in estimating the leakage rates. Please provide a summary of failure modes considered in the elicitation process.

RESPONSE

A summary of the failure modes considered in the review process for the South Texas Project is included in Attachment 1, Section 4.7.3. The South Texas Project application does not use the expert elicitation approach. Therefore, this request is not relevant to the South Texas Project application.

18.

Section 6.2 (pa-ge 6-2): Significant areas for deliberation were said to include: (1) the effects of aging on the containments and the resulting failure modes; (2) the fact that not all potential containment failure modes may appear in the current data; and (3) different containment types having the potential for different failure modes with potentially different failure rates. Please provide a discussion of the key points deliberated in each of these areas, and the view(s) of the expert group with regard to each key point. Include any views expressed by dissenting experts, including the two experts whose inputs were not used in developing the community distribution.

RESPONSE

The South Texas Project application does not use the expert elicitation approach.

Therefore, this request is not relevant to the South Texas Project application.

19.

Section 6.2 (page 6-2): Expert input was solicited for each of five containment failure modes: (1) construction errors or deficiency; (2) human error associated with testing or maintenance; (3) human error, design error, or other deficiency associated with modifications; (4) corrosion; and (5) fatigue. Based on the information provided in Section 2 and Appendix C, it is not possible to discern the key issues considered by each expert for each of the five failure modes, and ultimately, whether the experts were able to provide meaningful input for each of these failure modes. Please provide a brief description of the key issues considered by each expert for each of the five failure modes, and a characterization of their views regarding the relative importance of each failure mode to the overall failure probability.

RESPONSE

The South Texas Project application does not use the expert elicitation approach.

Therefore, this request is not relevant to the South Texas Project application.

20.

Section 6.2 (page 6-3): Corrosion is mentioned only briefly as a potential failure mode to be considered by the experts. In support of one-time, 15-year ILRT test interval extensions, licensees were requested to evaluate the potential contribution to large early release frequency (LERF) from shell/liner degradation mechanisms. Although the contribution from corrosion was typically less than 1 E-8 per year in these analyses, under alternative assumptions (e.g., relating to the increase in flaw likelihood, the likelihood of breach given a flaw, and likelihood of failure to detect a flaw developing from the liner back side) this contribution could be in the range of 5E-8 per year to 2E-7 per-year, and would be even greater for a 20-year interval extension. In this regard, please provide a quantitative evaluation of the potential impact of corrosion on NOC-AE-06001963 Page 10 of 13 LERF based on a 20-year interval extension and a methodology similar to that used in support of the one-time, 15-year test interval extensions.

RESPONSE, Section 4.7.5.9, provides the results of a quantitative evaluation of the potential impact of corrosion on LERF.

Section 7: Technical Approach

21.

Section 7.1 (page 7-4): Please further describe containment endstates/release modes that contribute to "Intact CDF." All CDF that does not lead to LERF/bypass (e.g., intermediate and late containment failures) should be considered for inclusion in this accident class. Additional guidance is also needed on whether/how events with containment sprays (for PWRs and BWRs) and suppression pools (for BWRs) are to be handled.

RESPONSE

"Intact CDF" is the frequency of an event with core damage consequence that does not have an associated leak route from containment. Containment endstates/release modes that contribute to "Intact CDF" are described in Attachment 1, Section 4.7.3. The South Texas Project application does not include special consideration for containment spray.

22.

Section 7.1 (page 7-4): The last sentence of the second bullet seems to indicate that the existing empirical data for small leaks has been disregarded and replaced by the probability developed by the expert elicitation process. Please explain why it is appropriate to supplant empirical data with the results of expert elicitation.

RESPONSE

The South Texas Project application does not use the expert elicitation approach.

Therefore, this request is not relevant to the South Texas Project application.

23.

Section 7.2 (page 7-4): The plant IPE or PRA are identified as possible sources for offsite dose estimates. Please expand this discussion to recognize that population dose estimates may have also been developed subsequent to the IPE, e.g., as part of the severe accident mitigation alternative analysis performed in support of license renewal. Plant-specific values can also be approximated based on offsite consequence analyses for similar plants, and appropriate scaling to account for site-to-site differences in meteorology and demography.

RESPONSE

A discussion of offsite dose estimates is provided in Attachment 1, Sections 4.7.5.5 and 4.7.5.6..

24.

Section 7.2 (page 7-4): A leak rate for Class 3b of 100 La is said to be conservative.

While 100 La may be conservative as a threshold for when a leak is considered to be large, it is non-conservative as the basis for quantifying the magnitude of a large leak.

As stated on page 3-2, a leakage of 600 %/day (or 600 to 6000 La) is more representative of a large early release. Accordingly, the doses for Class 3b should be assigned a value closer to 1000 La. Please justify the use of 100 La as conservative for Class 3b.

NOC-AE-06001963 Page 11 of 13

RESPONSE

The South Texas Project has selected a leak rate of 1000 La for Class 3B events when quantifying the magnitude of a large leak. See Attachment 1, Section 4.7.4.

25.

Section 7.5 (page 7-5): The change in probability of leakage detectable only by ILRT was determined by multiplying the baseline probability by the ratio of the new to the old test interval. Please justify this approach, since it presumes a constant containment degradation rate, which may not be reasonable over a 20-year test interval.

RESPONSE

The ratio of the new to the old test interval only considers the increase in risk due to the longer time that a flaw may go undetected. Attachment 1 Section 4.7.5.9 discusses the presumed containment degradation rate and assumes its progression is non-linear.

Section 8: Application of Technical Approach

26.

Section 8.1 (page 8-1): The hypothetical PWR CDF characteristics (i.e., breakdown of CDF by accident class) presented in Table 8-1 is not very representative of PWRs.

Specifically, in the example, 53% of the CDF is associated with a large release (Class 7 and 8) and only 47% of the CDF is associated with an intact containment. This will tend to understate the relative impact of the ILRT interval extension. (A more typical CDF breakdown would involve less than 10% early/bypass and 70 to 80% intact containment.) Please provide a justification for the basis of the example calculation or provide a calculation more representative of CDF characteristics to avoid biasing the results.

RESPONSE

The calculation results for the South Texas Project are based on CDF characteristics specifically for the South Texas Project.

27.

Sections 8.2 (pages 8-11): The doses presented in Table 8-1 for a hypothetical PWR are extremely large and not representative of values typically derived from PRA methods (as claimed on page 7-2). In general, dose values are expected to be on the order of 1 E+3 person-rem per event for Class 1, and on the order of 1 E+6 to 1 E+7 person-rem per event for Class 7 and 8. The dose values in Table 8-1 result in an annual population dose for the hypothetical plant of 68,000 person-rem per year, which is about three to four orders of magnitude greater than obtained from recent risk analyses submitted in support of license renewal, and is also 4 orders of magnitude greater than the value for the hypothetical BWR in Section 8.2. The example calculation should be based upon more representative dose values to avoid biasing the results. Finally, the sum of the population dose estimates for each accident class (presented as the "total" dose in Tables 8-1, 8-3, and 8-10) is not meaningful. The total dose is only meaningful if it is a probabilistically-weighted sum. Please delete reference to the "total doses".

RESPONSE

Dose values used in the calculations for the results in Attachment 1 are expected to be typical of the South Texas Project. Therefore, this issue is not relevant to the South Texas Project application.

NOC-AE-06001963 Page 12 of 13 The population dose estimates generated for Attachment 1, Section 4.7.5, are weighted by probability of occurrence for the selected Type A test intervals. Deletion of the reference should not be necessary.

28.

Section 8 5 (pagqe 8-6): The equation for A population dose does not yield the increase in population dose. Rather it yields the annual population dose (rate) corresponding to the extended test interval. Please express the A population dose as:

A population dose rate38 = population dose3a x [frequency3,, 1/10 - frequency 3a, 3/10].

RESPONSE

The change in population dose for the South Texas Project is determined for each accident class as described in Attachment 1, Section 4.7.5.6. The results are given in, Table 5.

29.

Section 8.6 (page 8-7): The information displayed in Table 8-6 (percentage values for each accident class) is not very useful for showing the impact of the ILRT extension on total population dose. Rather than reporting percentage values, please consider showing the population dose (per year) for each accident class, and the sum of these values over all accident classes in the table.

RESPONSE

Table 8-6 of the EPRI submittal gives the relative contributions of population dose over the accident classes for the various Type A test intervals. The South Texas Project application includes a table showing the projected population dose (per year) for each accident class, and the sum of the change in doses over all the accident classes in the table. See Attachment 1, Section 4.7.5.6 and Table 5.

Section 9: Results Summary and Conclusions

30.

Section 9 (page 9-1): The role of the EPRI report is unclear, i.e., whether it is intended to establish a methodology that can be used by licensees to support plant-specific license amendment requests to extend the ILRT test interval to 20 years, or whether it is intended to be a generic demonstration that the risk impact of extending the ILRT test interval to 20 years is very small for all containment designs and sites. The document appears to be oriented toward the former objective, and does not meet the latter intent for numerous reasons, including a very limited and biased number of example calculations, and the lack of any rationale or logic to support a conclusion that the assessments described are either representative or bounding for all designs and sites.

Please provide a detailed discussion of how the EPRI document is to be used by individual licensees and the NRC to support a permanent extension of the ILRT test interval to 20 years, including a description of any plant-specific analyses that would be required as part of plant-specific license amendment requests.

RESPONSE

The EPRI report is used only.for background information in developing the South Texas Project application.

B: Expert Elicitation Input Data

31.

Table B-2 (page B-3): If the experts supplied rationale for the probability estimates, pleaSe-supply-the documenhtatioh giVihn this ratindald. If the-reis-nb...........

documentation of the rationale, please justify the decision not to require such rationale to be documented.

NOC-AE-06001963 Page 13 of 13

RESPONSE

Table B-3 of the EPRI report provides results of expert elicitation for large containment with medium leakage pathway. The South Texas Project application does not use the expert elicitation approach. Therefore, this question is not relevant to the South Texas Project application.

C: Expert Elicitation Results

32.

Table C-5 (page C-7): In Table C-5, the aggregate upper bounds for La > 5 are all zero while the corresponding upper bounds for Experts A, D and E are all greater than zero.

Please explain how the entries in the tables in Section C were calculated.

RESPONSE

Table C-5 of the EPRI report provides results of statistical analysis of expert elicitation values for fatigue failure in large containments. The South Texas Project application does not use the expert elicitation approach. Therefore, this question is not relevant to the South Texas Project application.

33.

Figures C-1, C-2, and C-3 (pages C-15 and C-16): Page 7-3 indicates that the data used to develop these curves was "Detectable by ILRT Only (Failures)," but the data set used to produce Table 6-1 is not identified. Please identify whether the set of data used to produce these figures was based on "Total Degraded ILRTs" or "Detectable by ILRT Only (Failures)."

RESPONSE

Table 6-1 of the EPRI report presents expert elicitation results for leak size versus probability. The South Texas Project application does not use the expert elicitation approach. Therefore, this question is not relevant to the South Texas Project application.

ATTACHMENT 5 PROPOSED TECHNICAL SPECIFICATION CHANGES

ADMINISTRATIVE CONTROLS PROCEDURES AND PROGRAMS (Continued) j)

Containment Leakage Rate Testing Program A program shall be established to implement the leakage rate testing of the primary containment as required by 10 CFR 50.54(o) and 10 CFR Part 50, Appendix J, Option B, as modified by approved exemptions.

This program shall be in accordance with the guidelines contained in Regulatory Guide 1.163, "Performance-Based Containment Leak-Testing Program",

dated September 1995. The 6current :interval between perf ormance :of the ýintegrated 'leakage rate, (Tye"A) test, !beginning Se'ptember 24, 1991, for Unit 2 and March' 10,. 1995, for Unit 1, has been extended to 20 years (a one-time change)..

Peak calculated primary containment internal pressure for the design basis loss of coolant accident (LOCA), Pa is 41.2 psig.

The maximum allowable primary containment leakage rate, La, is 0.3% *of primary containment air weight per day.

Leakage rate acceptance criteria are:

a.

Primary containment overall leakage rate acceptance criterion is < 1.0 La.

During the first unit start-up following testing in accordance with this program, the leakage rate acceptance criteria are < 0.60 La for the combined Type B and Type C tests, and < 0.75 La as-left and < 1.0 La as-found for Type A tests.

b.

Air lock testing acceptance criteria for the overall air lock leakage rate is < 0.05 La when tested at > Pa.

The provisions of Surveillance Requirement 4.0.2 do not apply to the test intervals specified in the Containment Leakage Rate Testing Program.

The provisions of Surveillance Requirement 4.0.3 apply to the Containment Leakage Rate Testing Program.

k)

Configuration Risk Management Program (CRMP)

A program to assess changes in core damage frequency and cumulative core damage probability resulting from applicable plant configurations. The program should include the following:

1) training of personnel,
2) procedures for identifying plant configurations, the generation of risk profiles and the evaluation of risk against established thresholds; and
3) provisions for evaluating changes in risk resulting from unplanned maintenance activities.

SOUTH TEXAS - UNITS 1 & 2 6-18a Unit 1 -Amendment No. 84,85 Unit 2 - Amendment No. 74,-7-