Tech Spec Pages for Amendment Nos. 177 and 164 Regarding TS 3.3.3.6, Accident Monitoring Instrumentation,
ML071430251
Person / Time
Site: South Texas  
Issue date: 06/13/2007
From:
NRC/NRR/ADRO/DORL/LPLIV
To:
Donohew J N, NRR/DORL/LP4, 415-1307
Shared Package
ML071430225 List:
References
TAC MD0934, TAC MD0935
Download: ML071430251 (2)


Text

V/)

0

-1 C:

-3.

Cr.

a-:'

3 3

CD CD 03 3 CD. CD AC INSTRUMENT

1. Containment Pressure
2. Reactor. Coolant Outlet Temperature-T HOT (Wide Range)
3. Reactor Coolant Inlet Temperature-T COLD (Wide Range)
4. Reactor Coolant Pressure - Wide Range and Extended Range
5. Pressurizer Water Level
6. Steam Line Pressure
7. Steam Generator Water Level -

Narrow Range

8. Steam Generator Water Level -

Wide Range

9. Refueling Water Storage Tank Water Level
10. Auxiliary Feedwater Storage Tank Water Level
11. Auxiliary Feedwater Flow
12. Reactor Coolant System Subcooling Margin Monitoring TABLE 3.3-10 CIDENT MONITORING INSTRUMENTATION TOTAL MINIMUM NO. OF CHANNELS CHANNELS OPERABLE ACTION 43 4

.1 4 (1/loop) 4 (1/loop) 4 4

3 4

1 4/steam generator 4/steam generator 4 (1/steam generator) 1/steam generator 1/steam generator 4

35 35 37 43 43 43 35 37 37 35 36 I

3 3

1 1

4 (1/steam generator) 2 4

1

TABLE 3.3-10 (Continued)

ACTION 35-a.

ACTION STATEMENTS With the number of OPERABLE channels one less than the Minimum Channels Operable requirement, restore the inoperable channel to OPERABLE status within 30 days or submit a Special Report within the next 14 days describing the preplanned alternate method of monitoring, the cause of the inoperability, and the plans and schedule for restoring the instrumentation channels of the Function to OPERABLE status.

b.

With the number of OPERABLE channels two or more less than the Minimum Channels Operable requirement, restore one or more of the inoperable channels such that at least three channels are in OPERABLE status within 7 days, or be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

ACTION 36 - a.

With the number of OPERABLE channels one less than the Total Number of Channels requirements, restore one inoperable channel to OPERABLE status within 7 days, or be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

b.

With the number of OPERABLE channels less than the Minimum Channels Operable requirements, restore at least one inoperable channel to OPERABLE status within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />, or be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

ACTION 37 - a.

With the number of OPERABLE channels one less than the Total Number of Channels requirements, restore the inoperable channel to OPERABLE status within 31 days, or be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

b.

With the number of OPERABLE channels two less than the Total Number of Channels requirement, restore at least one inoperable channel to OPERABLE status within 7 days, or be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

c.

With the number of OPERABLE channels less than the Minimum Channels Operable requirement, restore at least one inoperable channel to OPERABLE status within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> or be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

SOUTH TEXAS - UNITS 1 & 2 3/4 ý-70 Unmit 1 Amendment No. 177.1