MONTHYEARML0522304032005-08-10010 August 2005 Technical Specification Pages Extension of Reactor Trip System and Reactor Trip Device Functional Test Intervals Project stage: Other ML0520101792005-08-10010 August 2005 Issuance of Amendment Extension of Reactor Trip System and Reactor Trip Device Functional Test Intervals Project stage: Approval ML0522904762005-08-30030 August 2005 TMI, Unit 1 - Correction of Errors in Amendment No. 255 Extension on Reactor Trip System and Reactor Trip Device Functional Test Intervals Project stage: Other 2005-08-10
[Table View] |
|
---|
Category:Letter
MONTHYEARRS-24-097, Notice of Intent to Pursue Subsequent License Renewal for Three Mile Island Nuclear Station, Unit 12024-10-23023 October 2024 Notice of Intent to Pursue Subsequent License Renewal for Three Mile Island Nuclear Station, Unit 1 ML24256A0422024-10-0404 October 2024 Updated Post-Shutdown Decommissioning Activities Report, Rev. 6 ML24240A1692024-09-18018 September 2024 Cy 2023 Summary of Decommissioning Trust Fund Status ML24242A3032024-09-0909 September 2024 Letter - Three Mile Island Station, Unit 2, Issuance of Amendment No. 68, Historic and Cultural Resources IR 05000320/20240012024-08-28028 August 2024 TMI-2 Solutions, LLC, Three Mile Island Nuclear Station, Unit 2 - NRC Inspection Report Nos. 05000320/2024001 and 05000320/2024002 ML24240A2222024-08-27027 August 2024 Response to Request for Additional Information for the TMI-2 Post-Shutdown Decommissioning Activities Report, Rev. 6 ML24220A2742024-08-15015 August 2024 Request for Additional Information Clarification Call Regarding Three Mile Island Station, Unit 2, Amended Post-Shutdown Decommissioning Activities Report, Rev. 6 ML24135A3292024-08-0909 August 2024 Amendment No 68, Historic and Cultural Resources Cover Letter IR 07200077/20240012024-06-18018 June 2024 Constellation Energy Generation, LLC, Three Mile Island Nuclear Station, Unit 1 - NRC Inspection Report No. 07200077/2024001 ML24157A3672024-06-13013 June 2024 Updated Post-Shutdown Decommissioning Activities Report Request for Additional Information Transmittal Letter ML24135A1972024-06-13013 June 2024 – Exemption from Select Requirements of 10 CFR Part 73 (EPID L-2023-LLE-0091 (Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting)) ML24151A6482024-06-0303 June 2024 Changes in Reactor Decommissioning Branch Project Management Assignments for Some Decommissioning Facilities ML24120A3242024-05-24024 May 2024 TMI-2 Email to Fws RS-24-055, 2023 Corporate Regulatory Commitment Change Summary Report2024-05-17017 May 2024 2023 Corporate Regulatory Commitment Change Summary Report ML24121A2472024-04-29029 April 2024 And Three Mile Island, Unit 2 - 2023 Occupational Radiation Exposure Annual Report ML24120A2552024-04-29029 April 2024 Annual Radiological Environmental Operating Report ML24113A0212024-04-18018 April 2024 (TMI-2), Supplement to Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation RS-24-002, Constellation Energy Generation, LLC - Annual Property Insurance Status Report2024-04-0101 April 2024 Constellation Energy Generation, LLC - Annual Property Insurance Status Report ML24092A0012024-03-28028 March 2024 (TMI-2), Decommissioning Trust Fund Annual Report ML24065A0042024-03-28028 March 2024 Submittal of 2023 Aircraft Movement Data Annual Report ML24088A0122024-03-28028 March 2024 Notification of Amended Post-Shutdown Decommissioning Activities Report (PSDAR) in Accordance with 10 CFR 50.82(a)(7), Revision 6 ML24085A2152024-03-25025 March 2024 (TMI-2) - Annual Notification of Property Insurance Coverage RS-24-023, Report on Status of Decommissioning Funding.2024-03-22022 March 2024 Report on Status of Decommissioning Funding. ML24052A0602024-03-20020 March 2024 – Exemption from Select Requirements of 10 CFR Part 73 (EPID L-2023-LLE-0061 (Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting)) ML24074A3922024-03-14014 March 2024 Response to Request for Additional Information for the TMI-2 Post-Shutdown Decommissioning Activities Report, Rev. 5 ML24075A0062024-03-14014 March 2024 List of Threatened and Endangered Species That May Occur in Your Proposed Project Location or May Be Affected by Your Proposed Project ML24073A2312024-03-13013 March 2024 And Three Mile Island Nuclear Station, Unit 2 - Management Change ML24044A0092024-02-12012 February 2024 License Amendment Request – Three Mile Island, Unit 2, Historic and Cultural Resources Review, Response to Request for Additional Information IR 05000320/20230042024-02-0707 February 2024 TMI-2 Solutions, LLC, Three Mile Island Nuclear Station, Unit 2 - NRC Inspection Report 05000320/2023004 ML24038A0222024-02-0505 February 2024 Achp Letter on Section 106 Programmatic Agreement Participation IR 05000289/20230062024-01-29029 January 2024 Constellation Energy Generation, LLC, Three Mile Island Nuclear Station, Unit 1 - NRC Inspection Report No. 05000289/2023006 ML23342A1242024-01-0909 January 2024 Independent Spent Fuel Storage Installation Security Inspection Plan ML23325A1092024-01-0505 January 2024 Review of the Management Plan for Three Mile Island Station, Unit No. 2, Debris Material ML23354A2062023-12-20020 December 2023 (TMI-2), Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation ML23354A2112023-12-20020 December 2023 Response to Request for Additional Information for the TMI-2 Post-Shutdown Decommissioning Activities Report, Rev. 5 IR 05000320/20230032023-11-28028 November 2023 TMI-2 Solutions, LLC, Three Mile Island Nuclear Station, Unit 2, NRC Inspection Report No. 05000320/2023003 ML23243A9082023-08-29029 August 2023 SHPO Letter to TMI-2 Regarding Section 106 Activities IR 05000320/20230022023-08-17017 August 2023 TMI-2 Solutions, LLC, Three Mile Island Nuclear Station, Unit 2 - NRC Inspection Report 05000320/2023002 ML23216A1782023-08-14014 August 2023 Consultation Letter to Steve Letavic for TMI-2 IR 05000289/20230052023-08-14014 August 2023 Constellation Energy Generation, LLC, Three Mile Island Nuclear Station, Unit 1 - NRC Inspection Report 05000289/2023005 ML23216A1772023-08-14014 August 2023 Consultation Letter to Rebecca Countess for TMI-2 ML23216A1732023-08-14014 August 2023 Consultation Letter to Christine Turner for TMI-2 ML23216A1742023-08-14014 August 2023 Consultation Letter to David Morrison for TMI-2 ML23216A1752023-08-14014 August 2023 Consultation Letter to Joanna Cain for TMI-2 ML23221A1402023-08-0808 August 2023 (TMI-2), Response to Requests for Additional Information for the TMI-2 Post-Shutdown Decommissioning Activities Report, Rev. 5 ML23213A2342023-08-0101 August 2023 Submittal of Defueled Safety Analysis Report and Decommissioning Quality Assurance Plan ML23200A1882023-07-31031 July 2023 TMI-2 Correction Letter Amendment 67 ML23209A7632023-07-28028 July 2023 Letter from PA SHPO to TMI-2 Solutions on Cultural and Historic Impacts of Decommissioning ML23192A8272023-07-10010 July 2023 TMI-2 Solutions, LLC - Response to SHPO Request for Additional Information for Er Project 2021PR03278.006, TMI-2 Decommissioning Project ML23167A4642023-07-0505 July 2023 Letter - TMI-2- Exemption 10 CFR Part 20 Append G Issuance 2024-09-09
[Table view] Category:License-Operating (New/Renewal/Amendments) DKT 50
MONTHYEARML24242A3022024-09-0909 September 2024 Enclosure - Three Mile Island Station, Unit 2, Amendment No 68 for Historic and Cultural Resources ML24135A3282024-08-0909 August 2024 License Amendment No 68 for Historic and Cultural Resources ML24135A3292024-08-0909 August 2024 Amendment No 68, Historic and Cultural Resources Cover Letter ML22189A1962022-08-30030 August 2022 Enclosure 1 - Three Mile Island, Unit 2 - Approval of License Amendment No. 65, TMI-2 Solutions Change of License Condition 2.C.(2) ML22234A2212022-08-25025 August 2022 Enclosure - Revised License Amendment No. 305 with Corrections ML22081A2322022-04-19019 April 2022 Enclosure 1 - Amendment No. 304 to Renewed License No. DPR-50 ML22074A0262022-04-0707 April 2022 Enclosure 1 - TMI-1 Amendment No. 303 ISFSI Only Emergency Plan ML22021B6592022-02-0101 February 2022 Issuance of Amendments Related to Order Approving Transfer of Licenses (EPID L-2022-LLM-0000) (Letter) ML22031A2762022-02-0101 February 2022 Issuance of Indemnity Agreement Amendments-Enclosure 2 ML22021B6602022-02-0101 February 2022 Issuance of Amendments Related to Order Approving Transfer of Licenses (EPID L-2022-LLM-0000)-Enclosure 1 ML20352A3812020-12-18018 December 2020 TMI-2 License Transfer Conforming Amendment ML20297A6272020-12-0404 December 2020 Issuance of Amendment No. 301 Removal of Cyber Security Plan License Condition ML20297A6352020-12-0303 December 2020 Issuance of Amendment No. 300 Deletion of Permanently Defueledt Technical Specification 3/4.1.4, Handling of Irradiated Fuel with Fuel Handling Building Crane ML20261H9252020-12-0202 December 2020 Issuance of Amendment No. 299 for Unit 1 Permanently Defueled Emergency Plan and Emergency Action Level Scheme Changes ML20279A3702020-12-0202 December 2020 Enclosure 2, Attachment 1: TMI-2 LTA Draft Conforming Amendment ML20279A3672020-12-0202 December 2020 Enclosure 2: TMI-2 Draft License Transfer Application La ML20134H9402020-07-0808 July 2020 Issuance of Amendments Revising the High Radiation Area Administrative Controls ML20021A0702020-04-0606 April 2020 Issuance of Amendments to Delete License Conditions for Decommissioning Trusts ML19211D3172019-08-29029 August 2019 Issuance of Amendment No. 297 Defueled Technical Specifications and Revised License Conditions ML19065A1142019-04-18018 April 2019 Issuance of Amendment No. 296 for Unit 1 Changes to Emergency Plan for Post-Shutdown and Permanently Defueled Condition ML18305B4192018-12-14014 December 2018 Issuance of Amendment No. 295 Changes to Technical Specifications Sections 1.0, Definitions, and 6.0, Administrative Controls, for Permanently Defueled Condition ML18206A2822018-08-0202 August 2018 Issuance of Amendments to Relocate the Staff Qualification Requirements ML17233A1382017-10-0505 October 2017 Three Mile Island Nuclear Station, Unit 1 - Issuance of Amendment 293 Re: Changes to Technical Specifications 5.4.2, 6.1.2, and 6.2.2 (CAC No. MF9462) ML17137A3932017-06-23023 June 2017 Three Mile Island Nuclear Station, Units 1 And 2 Issuance of Amendment Re: Changes to the Emergency Plan Related to Staffing (CAC No. MF8147) ML17055A6472017-05-0808 May 2017 Brunswick, Catawba, McGuire, Shearon Harris, and H. B. Robinson - Issuance of Amendments to Revise Technical Specifications to Adopt TSTF-522, Revision 0 (CAC Nos. MF8422, MF8423, MF8424, MF8425, MF8426, MF8427, MF8428, and MF8429) ML17079A0402017-03-21021 March 2017 Three Mile Island Nuclear Station, Unit 1 - Correction to License Page 4 Re: Issuance of Amendment No. 289 Dated October 1, 2015 (CAC No. MF6504) ML15225A1582015-10-0101 October 2015 Issuance of Amendment for Temporary Restoration of the Borated Water Storage Tank Cleanup and Recirculation Operation (TAC No. 6504) ML15153A2822015-07-30030 July 2015 Issuance of Amendments Revising the Completion Date for Milestone 8 of the Cyber Security Plan (TAC Nos. MF4728, MF4729, MF4730, MF4731, MF4732, MF4733, MF4734, MF4735, MF4736, MF4737, MF4738, MF4739, MF4740 ML15141A0582015-07-28028 July 2015 Issuance of Amendments Regarding Emergency Action Level Schemes (TAC Nos. MF4232-MF4251) ML15090A5842015-07-28028 July 2015 Issuance of Amendments Technical Specifications to Modify Reactor Coolant System Pressure Isolation Check Valve Maximum Allowable Leakage Limits ML15121A5892015-06-30030 June 2015 Issuance of Amendment Regarding Technical Specifications Task Force (TSTF) Traveler-523, Generic Letter 2008-01, Managing Gas Accumulation, Revision 2, Using the Consolidated Line Item Improvement Process ML14330A3002014-12-30030 December 2014 Issuance of Amendment to Eliminate Certain Technical Specifications Reporting Requirements ML14226A9402014-12-24024 December 2014 Issuance of Amendments Regarding the Emergency Plan Definition of Annual Training (TAC Nos. MF3003, MF3004, MF3005, MF3006, MF3007, MF3008.. ML13325A0232013-12-13013 December 2013 Issuance of Amendment Revision to the Pressure and Temperature Limit Curves and the Low Temperature Overpressure Protection Limits ML12209A3922012-09-0404 September 2012 Issuance of Amendment Revision to Steam Generator Program Inspection Frequencies and Tube Sample Selection ML1210804372012-05-0707 May 2012 Issuance of Amendment Administrative Technical Specification Changes ML1123605812011-09-14014 September 2011 Issuance of Amendment Maximum Allowable Power with Inoperable Main Steam Safety Valves ML1121504862011-08-22022 August 2011 Issuance of Amendment Relocation of Equipment Load List from Technical Specifications to Updated Final Safety Analysis Report ML1118613412011-08-10010 August 2011 Issuance of License Amendments Regarding Exelon Cyber Security Plan ML1031200692011-01-12012 January 2011 Issuance of Amendment Request to Relocate Surveillance Frequencies to a Licensee Controlled Program ML0927407912010-05-27027 May 2010 Issuance of Amendment Technical Specification Changes to Reflect Control Rod Drive Control System Upgrade ML1003204932010-03-11011 March 2010 License Amendment Technical Specification Changes Adopting TSTF-490-A, Revision 0, Deletion of E-Bar Definition and Revision to Reactor Coolant System Specific Activity Technical Specification ML0927104102009-10-22022 October 2009 Enclosure 1 - Exelon Generation Company, LLC - Renewed Facility Operating License ML0927104012009-10-22022 October 2009 Issuance of Renewed Facility Operating License No. DPR-50 for Three Mile Island, Unit 1 ML0923105302009-09-15015 September 2009 Issuance of Amendment Technical Specification Changes to Reflect Steam Generator Replacement ML0911100852009-05-0101 May 2009 Enclosure 1- Gpu Nuclear, Inc. Three Mile Island Nuclear Station, Unit 2 Docket No. 50-320- Amendment to Facility Possession- Only License ML0835002172009-03-23023 March 2009 Issuance of Amendments Related to Removal of References to NRC Generic Letter 82-12 ML0828203692009-02-24024 February 2009 Issuance of Amendment Deletion of Technical Specifications for Review and Audit, and Additional Administrative Changes ML0827705682009-01-0808 January 2009 Unit 1, Issuance of Conforming Amendments Direct Transfer of Facility Operating License to Exelon Generation Co., LLC ML0827500552008-12-23023 December 2008 Draft Amendment to Facility Operating License 2024-09-09
[Table view] |
Text
August 30, 2005 Mr. Christopher M. Crane President and Chief Executive Officer AmerGen Energy Company, LLC 4300 Winfield Road Warrenville, IL 60555
SUBJECT:
THREE MILE ISLAND NUCLEAR STATION, UNIT NO. 1 - CORRECTION OF ERRORS IN AMENDMENT NO. 255 RE: EXTENSION OF REACTOR TRIP SYSTEM AND REACTOR TRIP DEVICE FUNCTIONAL TEST INTERVALS (TAC NO. MC4903)
Dear Mr. Crane:
On August 10, 2005, the Nuclear Regulatory Commission (NRC) staff issued the subject Amendment No. 255 to Facility Operating License No. DPR-50 for the Three Mile Island Nuclear Station, Unit 1, in response to your application dated October 20, 2004.
After issuance, the NRC staff noted a number of errors. The Docket No. was typed as "50-219" where it should be "50-289." The License No. was typed as "DPR-16" where it should be "DPR-50." In addition, there were a number of typographic errors involving punctuation marks, misused upper case, misspelled word, etc. Accordingly, we are re-issuing both pages of the amendment, and page 4 of the safety evaluation. This discovery of errors did not change the NRC's staff's conclusion on the subject amendment.
We apologize if these errors caused you any inconvenience.
Sincerely,
/RA/
Peter S. Tam, Senior Project Manager, Section 1 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-289
Enclosure:
As stated cc w/encl: See next page
August 30, 2005 Mr. Christopher M. Crane President and Chief Executive Officer AmerGen Energy Company, LLC 4300 Winfield Road Warrenville, IL 60555
SUBJECT:
THREE MILE ISLAND NUCLEAR STATION, UNIT NO. 1 - CORRECTION OF ERRORS IN AMENDMENT NO. 255 RE: EXTENSION OF REACTOR TRIP SYSTEM AND REACTOR TRIP DEVICE FUNCTIONAL TEST INTERVALS (TAC NO. MC4903)
Dear Mr. Crane:
On August 10, 2005, the Nuclear Regulatory Commission (NRC) staff issued the subject Amendment No. 255 to Facility Operating License No. DPR-50 for the Three Mile Island Nuclear Station, Unit 1, in response to your application dated October 20, 2004.
After issuance, the NRC staff noted a number of errors. The Docket No. was typed as "50-219" where it should be "50-289." The License No. was typed as "DPR-16" where it should be "DPR-50." In addition, there were a number of typographic errors involving punctuation marks, misused upper case, misspelled word, etc. Accordingly, we are re-issuing both pages of the amendment, and page 4 of the safety evaluation. This discovery of errors did not change the NRC's staff's conclusion on the subject amendment.
We apologize if these errors caused you any inconvenience.
Sincerely,
/RA/
Peter S. Tam, Senior Project Manager, Section 1 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-289
Enclosure:
As stated cc w/encl: See next page DISTRIBUTION:
PUBLIC PDI-1 R/F RLaufer PTam MOBrien OGC ACRS GHill(2) Bellamy, RI DLPM DPR TBoyce AHowe IAhmed Accession Number: ML052290476 OFFICE PD1-1/PM PD1-1/LA ODI-1/SC NAME PTam MO'Brien RLaufer DATE 8/26/05 8/26/05 8/30/05 OFFICIAL RECORD COPY
AMERGEN ENERGY COMPANY, LLC DOCKET NO. 50-289 l THREE MILE ISLAND NUCLEAR STATION, UNIT NO. 1 l AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 255 License No. DPR-50
- 1. The Nuclear Regulatory Commission (the Commission) has found that:
A. The application for amendment by AmerGen Energy Company, LLC (the l licensee), dated October 20, 2004, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B. The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C. There is reasonable assurance: (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D. The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E. The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
Corrected by letter dated August 30,2005 l
- 2. Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.c.(2) of Facility l Operating License No. DPR-50 is hereby amended to read as follows: l (2) Technical Specifications The Technical Specifications contained in Appendix A, as revised through l Amendment No. 255, are hereby incorporated in the license. The AmerGen Energy Company, LLC, shall operate the facility in accordance with the l Technical Specifications.
- 3. This license amendment is effective as of the date of issuance and shall be implemented within 60 days of issuance.
FOR THE NUCLEAR REGULATORY COMMISSION
/RA/
Richard J. Laufer, Chief, Section 1 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation
Attachment:
Changes to the Technical Specifications Date of Issuance: August 10, 2005 Corrected by letter dated August 30, 2005 l
to be essentially the same as reported for the Oconee RTS design group in BAW-10167A, Supplement 3, and the STI extension is found to be an insignificant contributor to system unavailability or core damage risk. The licensee evaluated the recent 10 years worth of relevant plant-specific RTB failure-to-trip data to establish RTS unavailability at TMI-1. The licensee reported that only one RTB failure-to-trip incident was identified. In this failure, only the undervoltage (UV) trip device failed during monthly testing of the RTB while the redundant shunt trip device (temporarily bypassed to perform UV device test) was operable to trip the RTB. This demand-related failure rate is consistent with the expected frequency of one UV trip device failure in 11 years assumed in BAW-10167A, Supplement 3. The licensee stated that the failure experience from TMI-1 since publication of the topical report does not contradict any of the assumptions or conclusions of BAW-10167A, Supplement 3, or the NRCs associated SE.
Based on the above evaluation, the NRC staff finds the licensees justification for extending the TMI-1 reactor trip devices STI from monthly to quarterly sufficient. The licensees proposed extension is, therefore, acceptable.
3.3 Proposed TS Bases Changes The licensee also proposed to revise the associated TS Bases (contained on Page 4-2a and 4-2b of the TSs) associated with the above TS changes. The NRC staff reviewed the proposed changes and found the proposed changes to the TS Bases consistent with the proposed TS changes.
4.0 STATE CONSULTATION
In accordance with the Commission's regulations, the Pennsylvania State official was notified of l the proposed issuance of the amendment. The State official had no comments.
5.0 ENVIRONMENTAL CONSIDERATION
The amendment changes surveillance requirements. The NRC staff has determined that the amendment involves no significant increase in the amounts, and no significant change in the types, of any effluents that may be released offsite, and that there is no significant increase in individual or cumulative occupational radiation exposure. The Commission has previously issued a proposed finding that the amendment involves no significant hazards consideration, and there has been no public comment on such finding (69 FR 68181). Accordingly, the amendment meets the eligibility criteria for categorical exclusion set forth in 10 CFR 51.22(c)(9). Pursuant to 10 CFR 51.22(b) no environmental impact statement or environmental assessment need be prepared in connection with the issuance of the amendment.
Corrected by letter dated August 30, 2005 l
Three Mile Island Nuclear Station, Unit 1 cc:
Site Vice President - Three Mile Island Nuclear Director - Licensing and Regulatory Affairs Station, Unit 1 AmerGen Energy Company, LLC AmerGen Energy Company, LLC 200 Exelon Way, KSA 3-E P. O. Box 480 Kennett Square, PA 19348 Middletown, PA 17057 Rich Janati, Chief Senior Vice President - Nuclear Services Division of Nuclear Safety AmerGen Energy Company, LLC Bureau of Radiation Protection 4300 Winfield Road Department of Environmental Protection Warrenville, IL 60555 Rachel Carson State Office Building P.O. Box 8469 Vice President - Operations, Mid-Atlantic Harrisburg, PA 17105-8469 AmerGen Energy Company, LLC 200 Exelon Way, KSA 3-N Plant Manager - Three Mile Island Nuclear Kennett Square, PA 19348 Station, Unit 1 AmerGen Energy Company, LLC Vice President - Licensing and Regulatory Affairs P. O. Box 480 AmerGen Energy Company, LLC Middletown, PA 17057 4300 Winfield Road Warrenville, IL 60555 Regulatory Assurance Manager - Three Mile Island Nuclear Station, Unit 1 Regional Administrator AmerGen Energy Company, LLC Region I P.O. Box 480 U.S. Nuclear Regulatory Commission Middletown, PA 17057 475 Allendale Road King of Prussia, PA 19406 Ronald Bellamy, Region I U.S. Nuclear Regulatory Commission Chairman 475 Allendale Road Board of County Commissioners King of Prussia, PA 19406 of Dauphin County Dauphin County Courthouse Michael A. Schoppman Harrisburg, PA 17120 Framatome ANP Suite 705 Chairman 1911 North Ft. Myer Drive Board of Supervisors Rosslyn, VA 22209 of Londonderry Township R.D. #1, Geyers Church Road Vice President, General Counsel and Secretary Middletown, PA 17057 AmerGen Energy Company, LLC 2301 Market Street, S23-1 Senior Resident Inspector (TMI-1) Philadelphia, PA 19101 U.S. Nuclear Regulatory Commission P.O. Box 219 Middletown, PA 17057
Three Mile Island Nuclear Station, Unit 1 cc:
Dr. Judith Johnsrud National Energy Committee Sierra Club 433 Orlando Avenue State College, PA 16803 Eric Epstein TMI Alert 4100 Hillsdale Road Harrisburg, PA 17112 Correspondence Control Desk AmerGen Energy Company, LLC P.O. Box 160 Kennett Square, PA 19348 Manager Licensing - Three Mile Island Nuclear Station, Unit 1 Exelon Generation Company, LLC 200 Exelon Way, KSA 3-E Kennett Square, PA 19348 Associate General Counsel AmerGen Energy Company, LLC 4300 Winfield Road Warrenville, IL 60555