MONTHYEARML23158A1952023-08-30030 August 2023 R. E. Ginna - Issuance of Amendments to Adopt TSTF-273-A, Revision 2, Safety Function Determination Program Clarifications ML23180A2362023-06-29029 June 2023 Correction of Errors on Technical Specification Pages ML22090A0862022-04-29029 April 2022 Amendments to Adopt TSTF-541,Rev.2,Add Exceptions to Surveillance Requirements for Valves,Dampers Locked in Actuated Position RS-22-049, Constellation Energy Generation, LLC, Supplemental Information to Correct Typographical Errors in Constellation'S Application to Revise Technical Specifications to Adopt TSTF-541 Revision 2, Add Exceptions to Surveillance Requirements for2022-04-0404 April 2022 Constellation Energy Generation, LLC, Supplemental Information to Correct Typographical Errors in Constellation'S Application to Revise Technical Specifications to Adopt TSTF-541 Revision 2, Add Exceptions to Surveillance Requirements for V ML22067A0772022-03-31031 March 2022 Correction of License Amendment Nos. 337 and 315 to Revise Response Time Testing Definition ML21347A0382022-01-13013 January 2022 Issuance of Amendments to Revise Reactor Coolant Leakage Requirements JAFP-21-0089, Application to Revise Technical Specifications to Adopt TSTF-541 Revision 2, Add Exceptions to Surveillance Requirements for Valves and Dampers Locked in the Actuated Position2021-09-27027 September 2021 Application to Revise Technical Specifications to Adopt TSTF-541 Revision 2, Add Exceptions to Surveillance Requirements for Valves and Dampers Locked in the Actuated Position ML19165A2472019-08-26026 August 2019 Issuance of Amendment Nos 330 and 308 Relocation and Consolidation the Emergency Operations Facility and Joint Information Center for the Calvert Cliffs Nuclear Power Plant ML18365A3732019-01-22022 January 2019 Issuance of Amendment Nos. 328 and 306 to Extend Completion Time of Required Action D.3 of Technical Specification 3.8.1 to 14 Days ML18270A1302018-10-30030 October 2018 Issuance of Amendment Nos. 326 and 304 to Add Risk-Informed Completion Time Program ML17129A5062017-05-12012 May 2017 Plants, Units 1 and 2 - Correction to Technical Specification Pages 1.1-2, 1.1-3, and 1.1-4 to Correct Errors Introduced During the Issuance of Amendment Nos. 286 and 263 ML15352A1642016-03-17017 March 2016 Calvert Cliffs, Units 1 & 2 and Independent Spent Fuel Storage Installation; Nine Mile, Units 1 & 2 and R. E. Ginna - Issuance of Amendments Regarding the Emergency Plan Requalification Training Frequency for Emergency Response Organization Personnel ML15279A1912015-12-30030 December 2015 Issuance of Amendment Revision to Pressurizer Safety Valve Technical Specifications ML15211A0052015-08-17017 August 2015 Amendment Adoption of TSTF-425, Relocate Specific Surveillance Frequencies to a Licensee Controlled Program ML15223B2502015-08-14014 August 2015 and Nine Mile Point Nuclear Station, Unit No. 2- Copy of License Amendment Nos. 313, 291, 118, and 150 ML15161A3802015-07-30030 July 2015 R. E. Ginna and Nine Mile Point, Unit 2 - Issuance of Amendments Regarding Implementation of Technical Specification Task Force Traveler 523, Generic Letter 2008-01, Managing Gas Accumulation (TAC Nos. MF4405 - MF4409) ML15133A1442015-07-23023 July 2015 Amendment Regarding New Technical Specification 3.7.18 for Atmospheric Dump Valves ML15154A6612015-07-16016 July 2015 Amendment License Amendment Request to Extend Containment Leakage Rate Test Frequency ML14307A8422015-01-14014 January 2015 Issuance of Amendment Regarding the Adoption of Technical Specification Task Force (TSTF) 426, Revision 5, Revise or Add Actions to Preclude Entry Into LCO (Limiting Condition of Operation) 3.0.3 ML14280A5222014-10-21021 October 2014 Amendment Enhancements to Diesel Generator Surveillance Requirements (Tac Nos. ME9832 and ME9833) ML14239A4912014-10-21021 October 2014 Issuance of Amendments Regarding the Adoption of Technical Specification Task Force 501-A, Revision 1, Relocate Stored Fuel Oil and Lube Oil Volume Values to Licensee Control (TAC Nos. ME9794-95) ML14153A5622014-05-30030 May 2014 Response to Request for Additional Information Regarding Enhancements to Diesel Generator License Amendment Request ML14091A2972014-04-0101 April 2014 Issuance of Amendments to Conform the Renewed Facility Operating Licenses and Materials License to Reflect the Direct Transfer of Operating Authority (TAC Nos. MF2584, MF2585, and L24780) ML13308A3872013-10-31031 October 2013 Application for Technical Specification Improvement to Adopt TSTF-510-A, Revision 2, Revision to Steam Generator Program Inspection Frequencies and Tube Sample Selection. ML13030A1332013-01-28028 January 2013 License Amendment Request Eliminate Second Completion Times Limiting Time from Discovery of Failure to Meet an LCO ML1134104612012-01-11011 January 2012 Amendment Technical Specification Task Force Traveler 487-A, Revision 1, Relocate DNB Parameters to the COLR ML1129406452011-12-20020 December 2011 Technical Specification Interpretation for Calvert Cliffs Nuclear Power Plant Units 1 & 2 on Limiting Condition for Operation (LCO) Applicability (LCO) 3.0.5 ML1103902242011-02-18018 February 2011 License Amendment, Transition from Westinghouse Nuclear Fuel to Areva Nuclear Fuel ML1030101702010-10-25025 October 2010 License Amendment Request: Revision of Limiting Condition for Operation 3.0.5 ML1026505292010-09-22022 September 2010 9/22/10 E-Mail to P. S. Furio from J. Goshen Calvert Amendment 9 Tech Specs Page 5 ML1026605642010-09-17017 September 2010 Technical Specification Bases, Revisions 38 & 39, Section B 3.8 - Electrical Power Systems ML1009700702010-04-0505 April 2010 License Amendment Request: Section 5.0, Administrative Controls, Personnel Title Revisions & Administrative Changes ML0933500992009-11-23023 November 2009 License Amendment Request - Transition from Westinghouse Nuclear Fuel to Areva Nuclear Fuel ML0827603842008-10-0101 October 2008 Attachment 2, Marked Up Tech Spec Pages for License Amendment Request: Reporting of Reactor Vessel In-Service Inspection Information and Analyses in Support of Code Relief Request for Extension of Reactor Vessel.. ML0824706232008-08-29029 August 2008 License Amendment Request: Appendix K Measurement Uncertainty Recapture - Power Uprate Request ML0824106932008-08-28028 August 2008 Attachment (2), Marked Up Technical Specification Pages for License Amendment Request: Application for Technical Specification Change TSTF-491 ML0824806762008-08-27027 August 2008 License Amendment Request: Replacement of the Trisodium Phosphate Buffer with a Sodium Tetraborate Buffer, Attachment (2) Markup of Technical Specifications Pages ML0821104652008-07-29029 July 2008 Technical Specifications, Amendment Regarding Control Room Habitability ML0816503472008-06-11011 June 2008 Additional Information Control Room Habitability ML0805303882008-03-24024 March 2008 Units, 1 and 2 - Tech Spec Pages for Amendments 285 and 262 Addition of Limiting Condition of Operation 3.0.8 for Inoperable Snubbers ML0732004702007-12-20020 December 2007 Tech Spec Pages for Amendment Nos. 283 and 260 Use of Lead Fuel Assemblies and Change to Core Operating Limits Report Analytical Methods ML0734706402007-12-13013 December 2007 Supplement to Application for Technical Specification Change to Add LCO 3.0.8 on the Inoperability of Snubbers Using the Consolidated Line Item Improvement Process ML0724202032007-08-29029 August 2007 Tech Spec Pages for Amendments 281 and 258 Implementation of Alternative Radiological Source Term ML0712703712007-05-0202 May 2007 License Amendment Request Add LCO 3.0.9 on the Unavailability of Barriers Using the Consolidated Line Item Improvement Process ML0712002852007-04-25025 April 2007 Technical Specifications 3.1 and 3.2, Appendix B, Reporting Related to National Pollutant Discharge Elimination System (NPDES) Permit ML0708701102007-03-22022 March 2007 Request for Additional Information Regarding Implementation for Alternative Source Term ML0706103572007-02-27027 February 2007 License Amendment Request: Change to the Core Operating Limits Report Analytical Methods List ML0706104142007-02-27027 February 2007 License Amendment Request: Use of Lead Fuel Assemblies ML0703305992007-02-0101 February 2007 License Amendment Request: Revise Containment Sump Surveillance Requirement to Verify Strainer Integrity ML0632500502006-11-16016 November 2006 License Pages and Technical Specifications, Calvert Cliffs Units 1 & 2 2023-08-30
[Table view] |
Text
TABLE OF CONTENTS 3.5.5 Trisodium Phosphate (TSP) .. ................... 3.5.5-1 3.6 CONTAIN14ENT SYSTEMS ........... . ........................ 3.6.1-1 3.6.1 Containment ............... .. .. .. .. .. .. .. .. 3.6.1-1 3.6.2 Containment Air Locks ....................... .... . 3.6.2-1 3.6.3 Containment Isolation Valves ....................... 3.6.3-1 3.6.4 Containment Pressure ................................ 3.6.4-1 3.6.5 Containment Air Temperature ............... .. 3.6.5-1 3.6.6 Containment Spray and Cooling Systems .............. 3.6.6-1 3.6.7 Deleted 3.6.8 Iodine Removal System (IRS) ..... ?......... .. 3.6.8-1 3.7 PLANT SYSTEMS .......................................... 3.7.1-1 3.7.1 Main Steam Safety Valves (MSSVs)................... 3.7.1-1 3.7.2 Main Steam Isolation Valves (MSIVs) ................ 3.7.2-1 3.7.3 Auxiliary Feedwater (AFW) System................... 3.7.3-1 3.7.4 Condensate Storage Tank (CST) ...................... 3.7.4-1 3.7.5 Component Cooling (CC) System.. ......... 3.7.5-1 3.7.6 Service Water (SRW) System ......................... 3.7.6-1 3.7.7 Saltwater (SW) System .................. . . 3.7.7-1 3.7.8 Control Room Emergency Ventilation System (CREVS) .. 3.7.8-1 3.7.9 Control Room Emergency Temperature System (CRETS) .. 3.7.9-1 3.7.10 Emergency Core Cooling System (ECCS) Pump Room Exhaust Filtration System (PREFS) ............. 3.7.10-1 3.7.11 Spent Fuel Pool Exhaust Ventilation System (SFPEVS) ..... .. . ,. .. .. .. .. .. .. 3.7.11-1 3.7.12 Penetration Room Exhaust Ventilation System (PRESS) ....................................... 3.7.12-1 3.7.13 Spent Fuel Pool (SFP) Water Level .................. 3.7.13-1 3.7.14 Secondary Specific Activity ........................ 3.7.14-1 3.7.15 Main Feedwater Isolation Valves (MFIVs) ............ 3.7.15-1 3.7.16 Spent Fuel Pool (SFP) Boron Concentration ........... 3.7.16-1 3.7.17 Spent Fuel Pool (SFP) Storage ...................... 3.7.17-1 3.8 ELECTRICAL POWER SYSTEMS ............................... 3.8.1-1 3.8.1 AC Sources-Operating . . ................ ........ . 3.8.1-1 3.8.2 AC Sources-Shutdown ............... ........... . 3.8.2-1 3.8.3 Diesel Fuel Oil .................................... 3.8.3-1 3.8.4 DC Sources-Operating ........ ............................. 3.8.4-1 3.8.5 DC Sources-Shutdown ............................... 3.8.5-1 3.8.6 Battery Cell Parameters ............................ 3.8.6-1 3.8.7 Inverters-Operating ............................... 3.8.7-1 CALVERT CLIFFS - UNIT 1 iii Amendment No. 262 CALVERT CLIFFS - UNIT 2 Amendment No. 239
PAM Instrumentation 3.3.10 ACTIONS (continued)
CONDITION REQUIRED ACTION COMPLETION TIME C. One or more Functions C.1 Restore one 7 days with two required indication channel to indication channels OPERABLE status.
inoperable.
D. Required Action and D.1 Enter the Condition Immediately associated Completion referenced in Time of Condition C Table 3.3.10-1 for not met. the channel.
E. As required by E.1 Be in MODE 3. 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> Required Action D.1 and referenced in AND Table 3.3.10-1.
E.2 Be in MODE 4. 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> F. As required by F.1 Initiate action in Immediately Required Action D.1 accordance with and referenced in Specification 5.6.7.
Table 3.3.10-1.
CALVERT CLIFFS - UNIT 1 3.3.10-2 Amendment No. 262 CALVERT CLIFFS - UNIT 2 Amendment No. 239
PAM Instrumentation 3.3.10 SURVEILLANCE REQUIREMENTS
NOTE------------__ - _
These Surveillance Requirements apply to each PAM instrumentation Function in Table 3.3.10-1.
SURVEILLANCE FREQUENCY SR 3.3.10.1 Perform CHANNEL CHECK for each required 31 days indication channel that is normally energized.
SR 3.3..10.2 Deleted SR 3.3.10.3 -------------------NOTE-------------------
Neutron detectors, Core Exit Thermocouples, and Reactor Vessel Level Monitoring System are excluded from CHANNEL CALIBRATION.
Perform CHANNEL CALIBRATION on each 24 months indication channel.
CALVERT CLIFFS - UNIT 1 3.3.10-3 Amendment No. 262 CALVERT CLIFFS - UNIT 2 Amendment No. 239
PAM Instrumentation 3.3.10 Table 3.3.10-1 (page 1 of 2)
Post-Accident Monitoring Instrumentation CONDITIONS REQUIRED REFERENCED FROM INDICATION REQUIRED ACTION FUNCTION CHANNELS E.1
- 1. Wide Range Logarithmic Neutron Flux 2 F
- 2. Reactor Coolant Outlet Temperature 2 F
- 3. Reactor Coolant Inlet Temperature 2 F
- 4. RCS Subcooled Margin Monitor N/A
- 5. Reactor Vessel Water Level 2 G
- 6. Containment Water Level (wide 2 F range) 2
- 7. Containment Pressure F
- 8. Containment Isolation Valve 2 per F Position penetration flow path((b
- 9. Containment Area Radiation (high 2 range)
- 10. Pressurizer Pressure (wide range) 2 F I
- 11. Steam Generator Pressure 2 per steam F I generator
- 12. Pressurizer Level 2 F I
- 13. Steam Generator Water Level (wide 2 per steam F I range) generator CALVERT CLIFFS - UNIT 1 3.3.10-4 Amendment No. 262 CALVERT CLIFFS - UNIT 2 Amendment No. 239
PAM Instrumentation 3.3.10 Table 3.3.10-1 (page 2 of 2)
Post-Accident Monitoring Instrumentation CONDITIONS REQUIRED REFERENCED FROM INDICATION REQUIRED ACTION FUNCTION CHANNELS E.1
- 14. Condensate Storage Tank Level 2 F I.
- 15. Core Exit Temperature-Quadrant 1 2() F I
- 16. Core Exit Temperature-Quadrant 2 2(W) F I
- 17. Core Exit Temperature-Quadrant 3 2(" F I
- 18. Core Exit Temperature-Quadrant 4 2() F I
- 19. Pressurizer Pressure (low range) 2 F I
'a) Not required for isolation valves whose associated penetration is isolated by at least one closed and de-activated automatic valve, closed manual valve, check valve with flow through the valve secured, blind flange, or equivalent.
(b) Only one position indication channel is required for penetration flow paths with only one installed control room indication channel.
') A channel consists of two or more core exit thermocouples.
CALVERT CLIFFS - UNIT 1 3.3.10-5 Amendment No. 262 CALVERT CLIFFS - UNIT 2 Amendment No. 239