Text

TABLE OF CONTENTS 3.5.5 Trisodium Phosphate (TSP) .. ................... 3.5.5-1 3.6 CONTAIN14ENT SYSTEMS ........... . ........................ 3.6.1-1 3.6.1 Containment ............... .. .. .. .. .. .. .. .. 3.6.1-1 3.6.2 Containment Air Locks ....................... .... . 3.6.2-1 3.6.3 Containment Isolation Valves ....................... 3.6.3-1 3.6.4 Containment Pressure ................................ 3.6.4-1 3.6.5 Containment Air Temperature ............... .. 3.6.5-1 3.6.6 Containment Spray and Cooling Systems .............. 3.6.6-1 3.6.7 Deleted 3.6.8 Iodine Removal System (IRS) ..... ?......... .. 3.6.8-1 3.7 PLANT SYSTEMS .......................................... 3.7.1-1 3.7.1 Main Steam Safety Valves (MSSVs)................... 3.7.1-1 3.7.2 Main Steam Isolation Valves (MSIVs) ................ 3.7.2-1 3.7.3 Auxiliary Feedwater (AFW) System................... 3.7.3-1 3.7.4 Condensate Storage Tank (CST) ...................... 3.7.4-1 3.7.5 Component Cooling (CC) System.. ......... 3.7.5-1 3.7.6 Service Water (SRW) System ......................... 3.7.6-1 3.7.7 Saltwater (SW) System .................. . . 3.7.7-1 3.7.8 Control Room Emergency Ventilation System (CREVS) .. 3.7.8-1 3.7.9 Control Room Emergency Temperature System (CRETS) .. 3.7.9-1 3.7.10 Emergency Core Cooling System (ECCS) Pump Room Exhaust Filtration System (PREFS) ............. 3.7.10-1 3.7.11 Spent Fuel Pool Exhaust Ventilation System (SFPEVS) ..... .. . ,. .. .. .. .. .. .. 3.7.11-1 3.7.12 Penetration Room Exhaust Ventilation System (PRESS) ....................................... 3.7.12-1 3.7.13 Spent Fuel Pool (SFP) Water Level .................. 3.7.13-1 3.7.14 Secondary Specific Activity ........................ 3.7.14-1 3.7.15 Main Feedwater Isolation Valves (MFIVs) ............ 3.7.15-1 3.7.16 Spent Fuel Pool (SFP) Boron Concentration ........... 3.7.16-1 3.7.17 Spent Fuel Pool (SFP) Storage ...................... 3.7.17-1 3.8 ELECTRICAL POWER SYSTEMS ............................... 3.8.1-1 3.8.1 AC Sources-Operating . . ................ ........ . 3.8.1-1 3.8.2 AC Sources-Shutdown ............... ........... . 3.8.2-1 3.8.3 Diesel Fuel Oil .................................... 3.8.3-1 3.8.4 DC Sources-Operating ........ ............................. 3.8.4-1 3.8.5 DC Sources-Shutdown ............................... 3.8.5-1 3.8.6 Battery Cell Parameters ............................ 3.8.6-1 3.8.7 Inverters-Operating ............................... 3.8.7-1 CALVERT CLIFFS - UNIT 1 iii Amendment No. 262 CALVERT CLIFFS - UNIT 2 Amendment No. 239

PAM Instrumentation 3.3.10 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME C. One or more Functions C.1 Restore one 7 days with two required indication channel to indication channels OPERABLE status.

inoperable.

D. Required Action and D.1 Enter the Condition Immediately associated Completion referenced in Time of Condition C Table 3.3.10-1 for not met. the channel.

E. As required by E.1 Be in MODE 3. 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> Required Action D.1 and referenced in AND Table 3.3.10-1.

E.2 Be in MODE 4. 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> F. As required by F.1 Initiate action in Immediately Required Action D.1 accordance with and referenced in Specification 5.6.7.

Table 3.3.10-1.

CALVERT CLIFFS - UNIT 1 3.3.10-2 Amendment No. 262 CALVERT CLIFFS - UNIT 2 Amendment No. 239

PAM Instrumentation 3.3.10 SURVEILLANCE REQUIREMENTS


NOTE------------__ - _

These Surveillance Requirements apply to each PAM instrumentation Function in Table 3.3.10-1.

SURVEILLANCE FREQUENCY SR 3.3.10.1 Perform CHANNEL CHECK for each required 31 days indication channel that is normally energized.

SR 3.3..10.2 Deleted SR 3.3.10.3 -------------------NOTE-------------------

Neutron detectors, Core Exit Thermocouples, and Reactor Vessel Level Monitoring System are excluded from CHANNEL CALIBRATION.

Perform CHANNEL CALIBRATION on each 24 months indication channel.

CALVERT CLIFFS - UNIT 1 3.3.10-3 Amendment No. 262 CALVERT CLIFFS - UNIT 2 Amendment No. 239

PAM Instrumentation 3.3.10 Table 3.3.10-1 (page 1 of 2)

Post-Accident Monitoring Instrumentation CONDITIONS REQUIRED REFERENCED FROM INDICATION REQUIRED ACTION FUNCTION CHANNELS E.1

1. Wide Range Logarithmic Neutron Flux 2 F
2. Reactor Coolant Outlet Temperature 2 F
3. Reactor Coolant Inlet Temperature 2 F
4. RCS Subcooled Margin Monitor N/A
5. Reactor Vessel Water Level 2 G
6. Containment Water Level (wide 2 F range) 2
7. Containment Pressure F
8. Containment Isolation Valve 2 per F Position penetration flow path((b
9. Containment Area Radiation (high 2 range)
10. Pressurizer Pressure (wide range) 2 F I
11. Steam Generator Pressure 2 per steam F I generator
12. Pressurizer Level 2 F I
13. Steam Generator Water Level (wide 2 per steam F I range) generator CALVERT CLIFFS - UNIT 1 3.3.10-4 Amendment No. 262 CALVERT CLIFFS - UNIT 2 Amendment No. 239

PAM Instrumentation 3.3.10 Table 3.3.10-1 (page 2 of 2)

Post-Accident Monitoring Instrumentation CONDITIONS REQUIRED REFERENCED FROM INDICATION REQUIRED ACTION FUNCTION CHANNELS E.1

14. Condensate Storage Tank Level 2 F I.
15. Core Exit Temperature-Quadrant 1 2() F I
16. Core Exit Temperature-Quadrant 2 2(W) F I
17. Core Exit Temperature-Quadrant 3 2(" F I
18. Core Exit Temperature-Quadrant 4 2() F I
19. Pressurizer Pressure (low range) 2 F I

'a) Not required for isolation valves whose associated penetration is isolated by at least one closed and de-activated automatic valve, closed manual valve, check valve with flow through the valve secured, blind flange, or equivalent.

(b) Only one position indication channel is required for penetration flow paths with only one installed control room indication channel.

') A channel consists of two or more core exit thermocouples.

CALVERT CLIFFS - UNIT 1 3.3.10-5 Amendment No. 262 CALVERT CLIFFS - UNIT 2 Amendment No. 239