ML082410693
Jump to navigation
Jump to search
| ML082410693 | |
| Person / Time | |
|---|---|
| Site: | Calvert Cliffs (DPR-053, DPR-069) |
| Issue date: | 08/28/2008 |
| From: | Calvert Cliffs, Constellation Energy Group, Nuclear Generation Group |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML082410667 | List: |
| References | |
| Download: ML082410693 (2) | |
Text
ATTACHMENT (2)
MARKED UP TECHNICAL SPECIFICATION PAGES Calvert Cliffs Nuclear Power Plant, Inc.
August 28, 2008
MSIVs 3.7.2 ACTIONS (continued)
CONDITION REQUIRED ACTION COMPLETION TIME D.
Required Action and D.1 Be in MODE 3.
6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time of Condition C AND not met.
D.2 Be in MODE 4.
12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> SURVEILLANCE REQUIREMENTS SR 3.7.2.1 SURVEILLANCE Verify closure time of each MSIV is
-41 FREQUENCY In accordance with the Inservice Testing Program CALVERT CL IFFS - UNIT 1 CALVERT CL IFFS - UNIT 2 3.7.2-2 Amendment No. 227 Amendment No. 201