Final as Administered Scenarios for Byron Initial Examination - Dec 2003
ML040140787
Person / Time
Site: Byron  Constellation icon.png
Issue date: 12/01/2003
From: Foss T
Exelon Generation Co
To:
Office of Nuclear Reactor Regulation
References
50-454/03-301, 50-455/03-301
Download: ML040140787 (102)


Text

Byron 2003-301 Scenario 03-1 Simulation Facility Byron Scenario No. 1 Operating Test No. 2003-301 Examiners:

Applicant:

SRO RO BOP Initial Conditions:

IC-21, 100% power, BOL, equilibrium Xenon, steady state Turnover: 100% power. 1A Containment Spray Pump (CS) is OOS for a pump bearing replacement. 1C Heater Drain pump (HD) is OOS for an alignment and vibration problem. Annunciator 1-4-C5 alarmed 5 minutes ago.

Event No.

Malf. No.

Event Type*

Event Description Preload RP02A&B CS01A FW35C ED06D M RO SRO BOP M BOP Failure of RTB A&B to auto and manually open. (can be opened locally) 1A CS pump OOS Failure of CS to Actuate on Hi-3 Cnmt Press. Train B CS must be manually started from the MCR 1C HD pump OOS 6.9KV Breaker 1591 fails to ABT.

Preload (preload note)

C RO SRO 1SI8801A will not auto open nor open from the MCB 1SI8801B will not open automatically. Will open manually from MCB Turnover ED025 open C SRO Failure of DC input to Instrument inverter 113 1

N BOP SRO Ramp down turbine power to 1000 Mwe at directed MW/min 1

R RO SRO Lower reactor power using rods and/or boration.

2 RX21A 2500 I RO SRO 1PT-455 Controlling Pressurizer Pressure channel fails high (over 30 second ramp) 3 RX03E, 0 I BOP SRO Steam Flow Transmitter 1FT-532 (input to controlling channel) fails low over 3 minute ramp 4

RD09, 8 C RO SRO Automatic rod motion fails at 8 step per minute.

5 ED05D M BOP RO SRO SAT feed breaker to bus 159 trips opens, no ABT. Loss of RCS flow (Loop 1D) ATWS 6

RP02A,B M RO BOP SRO Reactor Trip Breakers fail to open / ATWS 7

TH06 M RO BOP SRO LOCA inside containment. Leads to high-3 containment pressure 8

preload C BOP RO SRO Failure of CS to auto actuate.

  • (N)ormal, (R)eactivity (I)nstrument, (C)omponent, (M)ajor Transient

Byron 2003-301 2

Scenario 03-1 SCENARIO OVERVIEW The Unit 1 is at 100% power. 1C HD pump is OOS for alignment and vibration problems. 1A CS Pump is OOS for a pump bearing replacement. Just prior to turnover annunciator 1-4-C5 BUS 113 INVERTER TROUBLE alarmed the SRO is directed to evaluate the alarm and determine Technical Specification 3.8.7 condition A applies. Restore the inverter to operable status within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. Ramp unit to 1000 MW.

Following clearly observable plant response from the reactivity changes, the controlling Pressurizer pressure channel (1PT-455) will fail high, causing Pressurizer PORV (1RY-455A) and Pressurizer spray valves to open, decreasing actual RCS pressure. The RO will diagnose the pressure malfunction from alarms, meter indications, and decreasing Pressurizer pressure. The RO must close the PORV or PORV block valve to stop the pressure decrease. Manual action will also be required to close the Pressurizer spray valves which will open due to the master pressure controller demand. The SRO will implement and direct actions of 1BOA INST-2, FAILED INSTRUMENT CHANNEL Attachment B to select an operable controlling channel and restore automatic pressurizer pressure control, trip required bistables, and identify Technical Specification Action requirements 3.3.1 Reactor Trip System Instrumentation Conditions E and K - trip channel within 6 hrs., 3.3.2 Engineered Safety Feature Actuation System Instrumentation Condition D - trip channel within 6 hrs., 3.3.4 Remote Shutdown System Condition A - Restore within 30 days, 3.4.1 DNB Limits Condition A -

Restore DNB within 2 hrs.

Following completion of actions for controlling Pressurizer pressure channel (1PT-455) failing high, the 1C S/G controlling steam flow channel (1FT-532) will fail low, resulting in indications of decreased steam flow and initial closing of 1C S/G Feedwater regulating valve to attempt to match feed flow with steam flow. S/G level will decrease and manual control of the feedwater regulating valve will be required to maintain normal level. The crew will perform the actions of 1BOA INST-2, FAILED INSTRUMENT CHANNEL-Attachment H.

After the unit is stabilized following the Steam Flow channel malfunction, breaker 1592 trips causing a loss of 6.9KV Bus 159. No ABT to the Unit Auxiliary Transformer (UAT) will occur, resulting in a loss of the 1D RCP. The Reactor Protection System will sense the loss of RCS flow and generate a reactor trip signal. The Reactor will fail to trip (ATWS), requiring manual rod insertion due to auto rod speed failed at 8 steps per minute, and emergency boration.

1BFR S.1, RESPONSE TO NUCLEAR POWER GENERATION / ATWS will be entered. After dispatching an operator to locally trip Unit 1 reactor, the reactor trip breakers will be opened only after placing the steam dumps in Off/Reset per step 7 of BFR S.1.

After the Reactor is tripped, a LOCA of 500 gpm occurs. The size of the LOCA will require SI actuation, cold leg injection valves 1SI8801A&B will fail to open. 1SI8801B must be opened manually from the MCB. The LOCA will increase to 400,000 GPM over 2 minutes after 1SI8801B is open.

CS will fail to automatically occur at the high-3 pressure setpoints. Manual action by the crew will be required to actuate train B of CS, either while performing the actions of 1BEP-0 or the SRO may elect to perform 1BFR Z.1, RESPONSE TO HIGH CONTAINMENT PRESSURE The scenario ends with completion of Step 6 of 1BEP-1 or Step 6 1BEP ES-1.3 Scenario EPlan classification is MS-3 Critical Tasks

1. FR-S.1--C Insert negative reactivity into the core by manually inserting RCCAs before completing step 4 of 1BFR-S.1
2. FR-S.1--A Manually trip the main turbine in 1BFR-S.1
3. EP-0--I Manually initiate high head injection flow via 1SI8801B before exiting 1BEP-0
4. EP-0--E:

Manually actuate at least the minimum required compliment of containment cooling equipment before an extreme (red path) challenge develops to the containment CSF

Byron 2003-301 3

Scenario 03-1 SIMULATOR OPERATOR NOTES:

Simulator Setup:

IC-21, 100% power. Hang YELLOW risk placard.

Ensure Delta I limits and Delta I band are correct for IC.

Ensure Steam Flow Channel 1FT-532 is select as controlling channel on 1C SG Take 1A CS pump OOS. Control switch to PULL OUT. Hang Tag Hang Tags on 1CS007A, 1CS019A, 1CS001A, 1CS009A Take 1C HD pump OOS. Control switch to PULL OUT. Hang Tag.

With the simulator running, in an expert window type cae d:\\byron\\2003_demos\\nrc1a.cae Ensure the following appear on the summary popup:

mf rp02a Failure of Reactor Trip Breakers to open in Auto and Manual mf rp02b Failure of Reactor Trip Breakers to open in Auto and Manual mf cs01a Failure of 1A CS Pump mf fw35c Failure of 1C HD pump mf ed06d Breaker 1591 fails to ABT rf ed053i open Breaker for 1SI8801A When used with the light overrides it appears the Valve is closed and energized.

If operators are dispatched to de-energize and open this valve, then use the Overrides to de-energize the valve, but do NOT open 1SI8801A.

or zlo1si880101 on 1SI8801A close light on or zlo1si8801A1 on 1SI8801A close light on rf rp75 out 1SI8801B will not auto stroke open on an SI 1CV8105 will not auto close 1B AFW pump LO pump wont auto start will not affect scenario as the AF Pump will still auto start rf ed062a open Breaker for1CS007A rf ed053m open Breaker for 1CS019A rf ed053a open Breaker for 1CS001A rf ed053b open Breaker for 1CS009A rf ed071g open Breaker for 1CS007B rf ed025 open DC Bus 111 feed to Inverter 113 or zdi1cs001a cls 1CS001A CS to close or zlo1cs007b1 on 1CS007B close light on Ensure the following triggers are setup:

Trigger 3 cs:7bxb.eq.1.and. zdi1cs007b(2).eq.1 command: mrf ed071g close trigger 4 csv1cs007b.gt.0.1 command dor zlo1cs007b1 This will require the candidate to place the 1B CS pump to PTL, wait 30 seconds and open 1CS007B then restart 1B CS Pump to establish flow to containment.

Trigger 6 siv1si8801b.eq. 1 command mmf th06a 400000 120

Byron 2003-301 4

Scenario 03-1 Preload Annunciator 1-4-C5 Failure of DC input to inverter 113 Acknowledge on request actions to prepare for placing inverter 113 on CVT.

Event 1 Load Ramp to 1000 Mwe As SM acknowledge ramp initiation.

As Radiation Protection/Chemistry acknowledge sample requirements for power change > 15% in one hour.

Event 2 Pressurizer Pressure Channel 1PT-455 failure high (2500#) (When RO in position to respond)

IMF RX21A, 2500 over 30 second ramp Initiate malfunctions after load ramp complete and with concurrence of lead examiner.

Role Play as U-2 assist/extra NSO to accomplish bistable tripping.

Acknowledge all info passed as SM, WEC, and maintenance.

Perform the following to trip Pressurizer channel bistables:

On SDG RX10:

Open Protection Cabinet Door #1 RX020 OPEN Pzr Press Hi Trip PB455AC1-153 BS-1 RX032 TRIP Pzr Press Lo Trip PB455C C1-153 BS-4 RX034 TRIP Pzr Lo Press SI PB455DC1-153 BS-3 RX035 TRIP Pzr Press P-11 PB455B C1-153 BS-2 RX033 TRIP On SDG RX4:

OTDT Trip TB411CC1-124 BS-3 RX013 TRIP OTDT Runback TB411DC1-124 BS-4 RX135 TRIP Protection Cab #1 Close Door RX020 CLOSE Event 3 Steam Flow Transmitter 1FT-532 (controlling channel) fails LOW Insert malfunction to fail 1C SG controlling steam flow channel, 1FT-532 LOW (RX03E, 0 180 second ramp) on SDG RX16 after bistables for Pressurizer channel 1PT-455 are tripped. or at the lead examiners cue.

Event 4 Automatic Rod Motion fails at 8 Step per Minute (RD09, 8)

Insert Rod Speed Failure Malfunction (RD09, 8) immediately prior to inserting the Loss of Bus 159 Event 5 Loss of Bus 159 and ATWS Initiate Major Accident sequence after the actions are completed for the failed steam flow transmitter, or at the lead examiners cue.

Event 6 Reactor Trip Breakers fail to open (ATWS)

The ATWS malfunction(s) are in Pre-load. If directed as a local operator to open the unit 1 reactor trip breakers prior to stream dumps being placed in OFF/RESET, wait until after the steam dumps have been placed in OFF/RESET. otherwise wait 1 minute then DELETE malfunctions RP02A and RP02B and modify Remote Functions RP01 & RP02 to TRIP to open the Reactor Trip Breakers Acknowledge direction to perform step 10c if 1BFR S.1 as NLO Acknowledge the call for the STA to monitor Status Trees.

Acknowledge all info passed to the SM, WEC, and maintenance.

Insert LOCA malfunction (TH06C, 500 gpm) at step 15 of BFR S.1

Byron 2003-301 5

Scenario 03-1 Event 7 LOCA inside Cnmt. Leads to failure of Hi-3 automatic actuations Ensure trigger set up to increase LOCA size upon 1SI8801B opening.

If asked for ETR on 1A CS, report 2-4 hours is optimistic.

Acknowledge direction to trip Control Room Vent fans as NLO Wait 2 minutes and report Control Room Vent fans have been tripped Acknowledge direction to energize SVAG valves per 1BEP 0 step 16b After CAEPs have finished running, report the SVAG valves have been energized USE CAEP bep0step16b2a to energize valves.

INSTRUCTOR NOTE: As STA, do NOT report on any status until AFTER containment pressure has decreased below 20 psig.

Event 8 Failure of CS to automatically actuate The failure of CS to auto actuate is in the Pre-load. Operators will manually align the CS system for operation.

Comments:

Byron 2003-301 6

Scenario 03-1 Scenario No:

03-1 Event No.

1 Event

Description:

Ramp down turbine and reactor power to 1000 MWe.

Time Position Applicants Actions or Behavior CUE Turnover. 100% power. 1A Containment Spray Pump (CS) is OOS for a pump bearing replacement. 1C Heater Drain pump (HD) is OOS for an alignment and vibration problem. Ramp Unit to 1000 Mwe @

5MW/min Annunciator:

1-4-C5 BUS 113 INVERTER TROUBLE Note: A portion of the power increase preparations may have been performed in the briefing room US Refer to Tech Specs, and determine the following:

 3.8.7 Electrical Power Systems Inverters-Operating Condition A - Restore inverter in 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

Implement actions of 1BGP 100-4, rev 25, step F.1 (OR per 1BGP 100-4T2)

US Direct load reduction to 1000 MWe at 5 MW/min

 Initiate load swing instruction sheet, 1BGP 100-4T2

 Contact Chemistry and HP for load change >15% in one hour

 Perform Reactivity Briefing CREW Review applicable Prerequisites, Precautions, Limitations and Actions of 1BGP 100-4

Comments:

Byron 2003-301 7

Scenario 03-1 Scenario No:

03-1 Event No.

1 Event

Description:

Ramp down turbine and reactor power to 1000 MWe.

Time Position Applicants Actions or Behavior RO Verify rod position and boron concentration Initiate boration, if required. (BOP CV-6)

 Determine required boric acid volume

 Effects of previously performed borations

 Boration / Dilution tables IF BATCH addition desired:

 Determine the desired change in RCS Tave

 Determine required gallons of boric acid to change Tave IF Calculated addition desired:

 Determine required gallons of boric acid to increase RCS boron as desired NOTE: The remaining steps will be performed for either method of boration

 Determine required boric acid flow rate

 Set 1FK-110 BA Flow Control to desired boration rate (may leave at current value if Batch method used)

 Set 1FY-0110 BA Blender Preset Counter to desired volume.

 Place MAKE-UP MODE CONT SWITCH to stop position

 Set MODE SELECT to bor position

 Place MAKE-UP MODE CONT SWITCH to start

 Verify proper operation of valves and BA transfer pump (1CV110B open, 1CV110A throttles open, Boric Acid Pump running, Boric Acid flow indicated on recorder.)

BOP Initiate turbine load reduction:

 Depress LOAD RATE MW/MIN

 Enter desired value for rate (5 MW/min)

 Depress ENTER

 Depress REF

 Enter desired final turbine loading (1000 MW)

 Depress ENTER

 When ready to begin load decrease, depress GO

 Verify load reduction occurring RO/BOP Monitor reactor power and load decrease

 Monitor Nuclear instruments, Tave, I, Pressurizer press/level

 Monitor MWe, turbine loading, EHC

Comments:

Byron 2003-301 8

Scenario 03-1 Scenario No:

03-1 Event No.

1 Event

Description:

Ramp down turbine and reactor power to 1000 MWe.

Time Position Applicants Actions or Behavior RO During Boration:

 Monitor VCT level and pressure

 Monitor Boric Acid blender counter

 Verify boration stops at preset value NOTE: Following clearly observable plant response from the reactivity changes and with the concurrence of the lead examiner, the next event may be initiated.

Comments:

Byron 2003-301 9

Scenario 03-1 Scenario No:

03-1 Event No.

2 Event

Description:

PT-455 Controlling Pressurizer Pressure Channel fails high Time Position Applicants Actions or Behavior CUE Annunciators:

1-12-B2 PZR PORV OR SAF VLV OPEN 1-12-C6 PZR PORV DSCH TEMP HIGH 1-12-D2 PZR PRESS CONT DEV HIGH PORV 1RY455A OPEN Position indicating light lit.

1PI-455 Indicating 2500 psig.

Pressurizer pressure decreasing RO Diagnose/Announce Pressurizer pressure transmitter failure, 1RY455A and Pressurizer sprays open:

 Determine Pressurizer pressure is decreasing, identify open PORV and spray valves

 Stop the Depressurization o Place Master Pressurizer pressure controller in manual and decrease o Close 1RY455A o Close 1RY8000A

 Manually:

o Close spray valves.

o Control Master Pressurizer pressure controller US Implement and direct actions of 1BOA INST-2 OPERATION WITH A FAILED INSTRUMENT CHANNEL, ATTACHMENT B, PZR PRESSURE CHANNEL FAILURE:

 Identify failed Pressurizer pressure channel 1PT455

 Get acknowledgements from RO and BOP.

 Recognize Technical Specification entry for DNB LCO

 Inform SM of plant status, evaluate for E-Plan.

 Direct WEC to write WR, CR, and get maintenance involved.

 Direct holding the ramp and boration US

 Briefs Unit 1 NSO and Unit 2 assist NSO on bistable tripping.

Comments:

Byron 2003-301 10 Scenario 03-1 Scenario No:

03-1 Event No.

2 Event

Description:

PT-455 Controlling Pressurizer Pressure Channel fails high Time Position Applicants Actions or Behavior RO Perform actions of 1BOA INST-2 as directed:

 Determine Pressurizer Pressure not normal

 Take Manual Control to restore Pressure.

 Determine Operable Channel not selected

 Place the Master Pressurizer Pressure Controller in Manual

 Control Pressurizer Pressure

 Select an operable channel.

 Check Pressurizer PORVs, Spray Valves and Heaters:

 PORVS Closed.

 Pressurizer Spray valves normal. If not, then manually control.

 Pressurizer Heaters normal.

 Check Pressurizer Pressure Control in automatic:

 1RY455A returned to automatic.

 1RY456 in automatic.

 Sprays in automatic (after operable channel selected for control).

 Master Pressurizer Pressure Controller in automatic.

 Select operable channels to Recorders:

 Pressurizer Pressure.

 Loop DeltaT.

 Coordinates bistable tripping:

o Places colored dots on bistable, indications, and annunciators.

o Maintains communications with NSO tripping bistables.

RO/BOP Ensures the following Bistables are tripped: (May wait to trip bistables, have 6 hrs to complete)

 PB455A

 PB455C

 PB455D

 PB455B

 TB411C

 TB411D

 Checks Pressurizer Pressure > 1930 psig and P-11 permissive is NOT Lit (Bypass Permissive 3.3).

BOP Perform actions as directed:

 Assist RO in monitoring panels and parameters.

 Investigate BARs.

 Make phone calls as directed to WEC and maintenance.

 Control load ramp

Comments:

Byron 2003-301 11 Scenario 03-1 Scenario No:

03-1 Event No.

2 Event

Description:

PT-455 Controlling Pressurizer Pressure Channel fails high Time Position Applicants Actions or Behavior US Refer to Tech Specs, and determine the following:

 3.3.1 Reactor Trip System Instrumentation Conditions E and K - trip channel within 6 hrs.

 3.3.2 Engineered Safety Feature Actuation System Instrumentation Condition D - trip channel within 6 hrs.

 3.3.4 Remote Shutdown System Condition A - Restore within 30 days

 3.4.1 DNB Limits Condition A - Restore DNB within 2 hrs.

NOTE: after completion of all actions and TS determination for the Pressurizer Instrument failure, and with the concurrence of the lead examiner, the next event may be initiated

Comments:

Byron 2003-301 12 Scenario 03-1 Scenario No:

03-1 Event No.

3 Event

Description:

Steam Flow Transmitter FT-532 (controlling channel) fails low Time Position Applicants Actions or Behavior CUE Annunciators:

1-15-C3 SG 1C FLOW MISMATCH STM FLOW LOW 1-15-C9 SG 1C LEVEL DEVIATION HIGH LOW 1FI-532 indication reading low 1FW530 throttling closed FW flow decreasing SG level decreasing below program BOP/US Identify/report steam flow channel 1FT-532 failure

 Take manual control of 1FW530 and increase feed flow above steam flow to restore level as necessary.

 Balance feed flow with steam flow to stabilize level as necessary.

 Take manual control of Master FW Pump Speed controller to establish adequate Feedwater pump Delta P US Implement and direct actions of 1BOA INST-2, OPERATION WITH A FAILED INSTRUMENT CHANNEL, Attachment H STEAM FLOW CHANNEL FAILURE:

 Get acknowledgements from RO and BOP.

 Inform SM of plant status, evaluate for E-Plan.

 Direct WEC to write WR, CR, and get maintenance involved.

 Direct holding load decrease BOP Perform actions as directed:

 Check affected SG levels normal. IF NOT:

 Place FRV in Manual

 Verify/establish adequate Feedwater pump Delta P

 Restore level to a stable condition.

 Select operable Steam flow channel

 Establish automatic level control

 Verify Steam Pressure channels normal

 Verify/restore Feedwater speed control in automatic RO Assist BOP as required to identify failed instrument channel and stabilize SG levels Monitor RCS and stabilize changing parameters resulting from feed flow/steam flow imbalance:

 RCS Tave

 Pzr Pressure

 Boration

 Load decrease

Comments:

Byron 2003-301 13 Scenario 03-1 Scenario No:

03-1 Event No.

3 Event

Description:

Steam Flow Transmitter FT-532 (controlling channel) fails low Time Position Applicants Actions or Behavior NOTE: Following the actions for the failed Steam flow channel and with the concurrence of the lead examiner, the next event may be initiated.

Comments:

Byron 2003-301 14 Scenario 03-1 Scenario No:

03-1 Event No.

4,5,6 Event

Description:

Loss of 6.9 KV Bus 159 no ABT resulting in a partial Loss of Flow ATWS. During ATWS Auto Control rod speed fails to 8 spm.

Time Position Applicants Actions or Behavior CUE Annunciators:

1-20-A6 BUS 159 Fd BRKR 1592 TRIP 1-20-D6 BUS 159 VOLT LOW 1-13-A2 RCP BUS UNDERVOLTAGE RX TRIP ALERT 1-13-D3 RCP 1D BRKR OPEN OR LOW FLOW ALERT 1-13-E3 RCP TRIP 1-11-A4 OPDT RX TRIP 1-11-C5 RCP LOW FLOW ABOVE P8 RX TRIP No voltage on Bus 159:

Loop 1D RCS flow coasting down Inward rod motion demanded at only 8 steps per minute.

CREW Diagnoses loss of Bus 159, 1D RCP, and RED First Out dictating need for Reactor Trip, but failure of Automatic Trip to occur.

US Implement and direct actions of 1BEP-0 "REACTOR TRIP OR SAFETY INJECTION" RO/BOP Perform immediate operator actions of 1BEP-0 Determine the reactor is not tripped:

 Rod bottom lights not lit

 Reactor trip & bypass breakers not open

 Neutron flux not decreasing Manually attempt to trip reactor with both switches at:

 1PM05J

 1PM06J RO Identify/report that reactor trip breakers did not open.

US Implement and direct actions of 1BFR-S.1 "RESPONSE TO NUCLEAR POWER GENERATION/ATWS"

 Contact WEC for STA duties NOTE: Crew may dispatch operator to locally open reactor trip breakers at any time.

Comments:

Byron 2003-301 15 Scenario 03-1 Scenario No:

03-1 Event No.

4,5,6 Event

Description:

Loss of 6.9 KV Bus 159 no ABT resulting in a partial Loss of Flow ATWS. During ATWS Auto Control rod speed fails to 8 spm.

Time Position Applicants Actions or Behavior RO Perform immediate operator actions of FR-S.1:

 Verify reactor is not tripped

 Rod Bottom lights not lit

 Reactor trip breakers not open; Bypass breakers open (not racked in)

 Neutron flux not decreasing from Post Trip.

 Manually attempt to trip reactor with both switches at:

 1PM05J

 1PM06J RO

[CT]

FR-S.1--C Insert control rods at 48 spm in Manual. (automatic is failed to 8 spm)

BOP

[CT]

FR-S.1--A Verify turbine trip

 Turbine throttle valves not closed

 Turbine governor valves not closed

 Manually trip turbine Check AFW Pumps Running

 AFW Pump run lights not lit

 Manually start AFW pumps RO/BOP Initiate Emergency Boration of RCS

 Check at least one centrifugal charging pump running

 Open 1CV8104

 Start boric acid transfer pump

 Check emergency boration flow - GREATER THAN 30 GPM

 Verify charging flow - GREATER THAN 30 GPM RO Check Pressurizer pressure - Less than 2335 psig BOP Verify Containment Ventilation Isolation

 Group 6 Containment Vent Isolation monitor lights lit

Comments:

Byron 2003-301 16 Scenario 03-1 Scenario No:

03-1 Event No.

4,5,6 Event

Description:

Loss of 6.9 KV Bus 159 no ABT resulting in a partial Loss of Flow ATWS. During ATWS Auto Control rod speed fails to 8 spm.

Time Position Applicants Actions or Behavior RO Verify reactor subcritical

 PR channels < 5%

 IR channels SUR < 0 Determine the power is still above 5% and continue with steps of 1BFR-S.1.

BOP Isolate Steam Dumps

 Place steam dump BYPASS INTERLOCK switches to OFF/RESET for both trains.

NOTE: Reactor trip breakers will be locally opened after dumps are in OFF/RESET.

CREW Check trips have occurred

 Reactor trip.

 Turbine trip BOP Check SG levels

 Level in at least one SG > 10% if not, verify > 900 gpm AFW flow

 Control feed flow to maintain SG levels between 10% (31% adverse) and 50%

 Check SG blowdown isolation valves closed: 1SD002A-H RO Verify all dilution path valves closed

 Reactor Makeup dilution valves 1CV111A and 1CV111B closed

 Verify BTRS Mode Selector in off

 Dispatch operator to locally check valves closed per 1BFR S.1 step 10c CREW Stop reactivity insertion from RCS cooldown

 RCS temperature not decreasing in uncontrolled manner

 SG pressure, none decreasing in uncontrolled manner RO Check CETCs < 1200F NOTE: 500 gpm LOCA will start here RO Verify reactor subcritical

 PR channels < 5%

 IR channels SUR < 0

Comments:

Byron 2003-301 17 Scenario 03-1 Scenario No:

03-1 Event No.

7,8 Event

Description:

LOCA / Failure of CS to actuate Time Position Applicants Actions or Behavior CUE Annunciators:

1-1-A2 CNMT DRAIN LEAK DETECT FLOW HIGH Pressurizer pressure decreasing Pressurizer level decreasing Containment pressure increasing US Implement and direct the actions of 1BEP-0 REACTOR TRIP OR SAFETY INJECTION o

Get acknowledgements from RO and BOP.



Informs SM of plant status for evaluation of E-Plan RO Perform Immediate Actions of 1BEP-0 Verify reactor trip

 Rod bottom lights lit

 Reactor trip and bypass breakers open

 Flux decreasing BOP Verify Turbine tripped

 All throttle valves closed

 All governor valves closed Verify 4KV ESF Busses energized

 Bus 141 bus alive light lit

 Bus 142 bus alive light lit CREW Determine SI needed/actuated:

 SI First Out Annunciator lit (1-11-B/C/D/E1)

 SI ACTUATED lit (1-BP-4.1)

 SI Equipment actuated

 Manually Actuate SI CREW (If manual SI not previously performed) Recognize and respond to conditions requiring a Safety Injection in accordance with 1BEP-0 REACTOR TRIP OR SAFETY INJECTION, Step 4:

 Pressurizer pressure cannot be maintained > 1829 psig

 Pressurizer level cannot be maintained > 4%

 Manually initiate SI

Comments:

Byron 2003-301 18 Scenario 03-1 Scenario No:

03-1 Event No.

7,8 Event

Description:

LOCA / Failure of CS to actuate Time Position Applicants Actions or Behavior BOP/US Verify Feedwater isolation:

 FW pumps tripped

 Isolation monitor lights lit

 FW discharge valves (1FW002A/B/C) closed RO/US NOTE: 1SI8801B may be opened at this point while verifying pump alignments (CT on page 20)

Verify ECCS pumps running:

 CV pumps

 SI pumps

 RH pumps BOP/US Verify Containment Conditions:

 RCFC Accident Mode lights lit (Group 2)

 Phase A lights lit (Group 3)

 Containment Ventilation lights lit (Group 6)

BOP/US Verify the following:

 AFW Aligned:

 1A and 1B AFW pumps running

 1AF013A-H open

 1AF005A-H throttled

 1A and 1B CCW pumps running

 1A and 1B SX pumps running

 Main Steam isolation valves and Main Steam isolation bypass valves isolated when Containment pressure

>8.2 psig NOTE: RCP Trip criteria may be met at this point RO/BOP Determine if RCPs meet trip criteria

 Controlled cooldown not in progress

 RCS pressure <1425 psig

 High head SI flow indicator (1FI-917) >100 gpm or SI pump discharge flow >200 gpm

 Trip RCPs

Comments:

Byron 2003-301 19 Scenario 03-1 Scenario No:

03-1 Event No.

7,8 Event

Description:

LOCA / Failure of CS to actuate Time Position Applicants Actions or Behavior BOP/US

[CT]

EP-0E NOTE: This sequence may not happen until the size of the LOCA is increased.

Check If Containment Spray required:

 Containment pressure > 20 psig

 Group 6 lights NOT lit Identifies/reports B Train of CS not operating properly

 Manually actuates both switches for CS and Phase B actuation at 1PM05J and 1PM06J

 Determines manual actuation unsuccessful. Performs Attachment B. (Train A CS is OOS)

 1CS001B open

 1CS007B closed

 Places 1B CS pump PULL OUT

 Verify TEST switch to normal

 Opens 1CS007B after 30 second time delay

 Restarts 1B CS pump

 Verify 1CS019B open

 Verify 1CS010B open

 Verify 1 CS pump running

 Phase B lights Lit

 Stop All RCPs

 Verifies Eductor Suction flow > 15 gpm (1FI-CS014)

 Verifies CS Additive flow > 5 gpm (1FI-CS016)

BOP Align SX Cooling Towers

 All eight riser valves open

 0SX163A thru 0SX163H

 All four Hot Water Basin Bypass valves closed

 0SX162A thru 0SX162D

 All eight SX Cooling Tower Fans running in high speed.

BOP Verify Total AFW flow:

 AFW flow > 500 gpm

 SG levels maintained between 10% (31% Adverse) and 50%

 SG levels not increasing in an uncontrolled manner

Comments:

Byron 2003-301 20 Scenario 03-1 Scenario No:

03-1 Event No.

7,8 Event

Description:

LOCA / Failure of CS to actuate Time Position Applicants Actions or Behavior RO

[CT]

EP-0--I Verify ECCS valve alignment

 Group 2 Cold Leg Injection monitor lights lit - OPEN 1SI8801B

 Align SVAG Valve power switches and dispatch NLO to energize breakers ECCS Operations:

 High Head SI flow > 100 gpm

 RCS pressure < 1700 psig

 SI pump flow > 200 gpm

 RCS pressure < 325 psig o

RH pump flow > 1000 gpm Pressurizer PORV relief path available:

 At least one block valve energized

 PORV in automatic

 Associated block valve open BOP Verify Main Generator Trip:

 Output Breakers open

 PMG Breaker open EDGs running

 1SX169A and B open

 Dispatch operator for local check of EDG operation Examiners note: US and RO will likely continue in 1BEP-0 while BOP is performing the next 3 ventilation steps:

Comments:

Byron 2003-301 21 Scenario 03-1 Scenario No:

03-1 Event No.

7,8 Event

Description:

LOCA / Failure of CS to actuate Time Position Applicants Actions or Behavior BOP Verify Control Room ventilation aligned for emergency operations:

 Dispatch NLO to trip VV supply fans

 Operating VC train equipment running

 Supply fan

 Return fan

 M/U fan

 Chilled water pump

 MCR chiller 0A running

 Operating VC train dampers

 M/U fan outlet damper not full closed 0VC24Y

 VC train M/U filter light lit

 Operating VC train Charcoal Adsorber aligned for train A

 0VC43Y closed

 0VC21Y open

 0VC22Y open

 Control Room pressure greater than +0.125 inches water on 0PDI-VC038 BOP Verify Auxiliary Building ventilation aligned

 Two inaccessible filter plenums aligned

 Plenum A fan 0VA03CB running

 Damper 0VA023Y open

 Damper 0VA436Y closed

 Plenum C fan 0VA03CF running

 Damper 0VA072Y open

 Damper 0VA438Y closed BOP Verify FHB ventilation aligned

 Train B fan 0VA04CB running

 0VA055Y open

 0VA062Y open

 0VA435Y closed RO/US Check Pressurizer sprays & PORVs closed

 Normal spray valves closed 1RY455B and 1RY455C

 PORVs closed 1RY455A and 1RY456

Comments:

Byron 2003-301 22 Scenario 03-1 Scenario No:

03-1 Event No.

7,8 Event

Description:

LOCA / Failure of CS to actuate Time Position Applicants Actions or Behavior CREW Maintain RCS temperature control

 With any RCP running, RCS Tave stable at or trending to 557 degrees F.

 With No RCP running, RCS Cold Leg temperature stable at or trending to 557 degrees F.

CREW Check status of RCPs

 Determine if RCPs are running.

 Check if RCPs should be stopped:

 ECCS flow-high head > 100 gpm; or SI pump > 200 gpm.

 RCS pressure < 1425 psig.

 Controlled cooldown NOT in progress, nor previously initiated.

 Stop All RCPs.

BOP/CREW Check Secondary Pressure Boundaries are intact

 No SG pressure decreasing in uncontrolled manner

 No SG completely depressurized BOP/CREW Check SG tube intact

 No abnormal secondary radiation BOP/CREW Check RCS intact

 Containment area radiation monitors > alert alarm setpoints

 Containment pressure > 3.4 psig

 Containment sump level lights lit US Implement and direct actions of 1BEP-1, LOSS OF REACTOR OR SECONDARY COOLANT o Get acknowledgements from RO and BOP.

 Informs SM of plant status for evaluation of E-Plan RO Check RCPs

 No RCPs running

Comments:

Byron 2003-301 23 Scenario 03-1 Scenario No:

03-1 Event No.

7,8 Event

Description:

LOCA / Failure of CS to actuate Time Position Applicants Actions or Behavior BOP Check SG Secondary pressure boundaries intact

 No SG Pressure decreasing uncontrollably

 No SG completely depressurized Check intact SG levels

 Narrow range levels > 10% (31% Adverse)

 Control Intact SG levels to 10% (31% Adverse) to 50% NR level

 Narrow range levels NOT increasing in uncontrolled manner Check Secondary Radiation levels normal

 No abnormal secondary radiation RO Check Pressurizer PORVs and isolation valves:

 PORV Isolation valves open and energized

 1RY8000A

 1RY8000B

 PORVs closed

 1RY455A

 1RY456 CREW Check if ECCS flow should be reduced:

 RCS Subcooling not acceptable

 Secondary heat sink acceptable

 RCS pressure decreasing

 Pzr Level <12%

Determine ECCS flow should NOT be reduced.

NOTE: Scenario Termination criteria is completion of step 6 of 1BEP-1 or step 6 1BEP ES-1.3 Scenario EPlan classification is MS-3 US Implement and direct actions of 1BEP ES-1.3, TRANSFER TO COLD LEG RECIRCULATION when RWST level < 46% (Actions on page 25)

Comments:

Byron 2003-301 24 Scenario 03-1 Scenario No:

03-1 Event No.

7,8 Event

Description:

LOCA / Failure of CS to actuate Time Position Applicants Actions or Behavior NOTE: At some time Containment pressure may rise to an ORANGE Path condition (without CS pumps running). If so, performance of 1BFR Z.1 RESPONSE TO HIGH CONTAINMENT PRESSURE may be required. Actions are covered below. CUE will be provided by the STA after monitoring the BSTs.

US Implement and direct as advised by the STA the actions of 1BFR-Z.1, RESPONSE TO HIGH CONTAINMENT PRESSURE.

o Get acknowledgements from RO and BOP.

 Inform SM of plant status for evaluation of E-Plan BOP Verify Containment isolations

 Phase A Group 3 lights lit

 Containment Ventilation Group 6 lights lit Check if Containment Pressure has increased to > 20 psig (1PR-937 or 1PI-CS934 thru 937)

 Stop all RCPs (previously completed)

Verify CS alignment: (previously complete for B Train)

US/BOP Verify Group 6 Phase B isolation lights lit (previously completed)

Verify RCFCs running in accident mode (Group 2 lights lit).

Verify Main Steam Isolation

 Main Steam isolation valves and Main Steam isolation bypass valves closed. (previously completed)

Determine NO SGs are faulted:

 No Steam Generator pressure decreasing in an uncontrolled manner

 No Steam Generator completely depressurized Return to step and procedure in effect.

Comments:

Byron 2003-301 25 Scenario 03-1 Scenario No:

03-1 Event No.

7,8 Event

Description:

LOCA / Failure of CS to actuate Time Position Applicants Actions or Behavior NOTE: ACTIONS FOR 1BEP ES-1.3, TRANSFER TO COLD LEG RECIRCULATION BOP/RO Perform actions of 1BEP ES-1.3 as directed:

Check CC pumps 2 running Open CC to RH Heat exchanger isolation valves

 1CC9412A and 1CC9412B Check CC flows to RH Heat exchanger

 >5000 gpm Verify adequate Containment sump level

 Bottom 4 lights lit Align RH pump suctions to Containment sumps:

 Place control switches for SVAG valves 480 bus feeds in close

 Check Both RH pumps running

 Check open 1SI8811A and 1SI8811B

 Close 1SI8812A and 1SI8812B Check SI and CV pumps in injection mode:

 SI pumps both running

 Cold Leg Injection valves (1SI8801A/B) open Align SI and CV pumps for Cold Leg Recirculation:

 Dispatch operator to energize 1SI8806 and 1SI8813

 Verify CV pump 1A miniflow isolation valves closed

 1CV8111 and 1CV8114

 Close SI pump miniflow isolation valves

 1SI8814, 1SI8920, and 1SI8813 when power restored

 Close RH Heat exchanger Discharge Cross ties

 1RH8716A and B

 Open SI and CV pump suction header Cross ties

 1SI8807A and B, and 1SI8924

 Check 1A RH pump running

 Open 1CV8804A

 Check 1B RH pump running

 Open 1SI8804B Start ECCS pumps as necessary (NOTE: Scenario may be terminated at this point)

1 Simulation Facility Byron Scenario No. 1a Operating Test No. 2003-301 Examiners:

Applicant:

SRO RO BOP Initial Conditions:

IC-21, 100% power, BOL, equilibrium Xenon, steady state Turnover: 100% power. 1A Containment Spray Pump (CS) is OOS for a pump bearing replacement. 1C Heater Drain pump (HD) is OOS for an alignment and vibration problem. Annunciator 1-4-C5 alarmed 5 minutes ago.

Event No.

Malf. No.

Event Type*

Event Description Preload RP02A&B CS01A FW35C ED06D M RO SRO BOP M BOP Failure of RTB A&B to auto and manually open. (can be opened locally) 1A CS pump OOS Failure of CS to Actuate on Hi-3 Cnmt Press. Train B CS must be manually started from the MCR 1C HD pump OOS 6.9KV Breaker 1591 fails to ABT.

Preload (preload note)

C RO SRO 1SI8801A will not auto open nor open from the MCB 1SI8801B will not open automatically. Will open manually from MCB Turnover ED025 open C SRO Failure of DC input to Instrument inverter 113 1

N BOP SRO Ramp down turbine power to 1000 Mwe at directed MW/min 1

R RO SRO Lower reactor power using rods and/or boration.

2 RX21A 2500 I RO SRO 1PT-455 Controlling Pressurizer Pressure channel fails high (over 30 second ramp) 3 RX03E, 0 I BOP SRO Steam Flow Transmitter 1FT-532 (input to controlling channel) fails low over 3 minute ramp 4

RD09, 8 C RO SRO Automatic rod motion fails at 8 step per minute.

5 ED05D M BOP RO SRO SAT feed breaker to bus 159 trips opens, no ABT. Loss of RCS flow (Loop 1D) ATWS 6

RP02A,B M RO BOP SRO Reactor Trip Breakers fail to open / ATWS 7

TH06 M RO BOP SRO LOCA inside containment. Leads to high-3 containment pressure 8

preload C BOP RO SRO Failure of CS to auto actuate.

  • (N)ormal, (R)eactivity (I)nstrument, (C)omponent, (M)ajor Transient

Byron 2003-301 2

Scenario 03-1 SCENARIO OVERVIEW The Unit 1 is at 100% power. 1C HD pump is OOS for alignment and vibration problems. 1A CS Pump is OOS for a pump bearing replacement. Just prior to turnover annunciator 1-4-C5 BUS 113 INVERTER TROUBLE alarmed the SRO is directed to evaluate the alarm and determine Technical Specification 3.8.7 condition A applies. Restore the inverter to operable status within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. Ramp unit to 1000 MW.

Following clearly observable plant response from the reactivity changes, the controlling Pressurizer pressure channel (1PT-455) will fail high, causing Pressurizer PORV (1RY-455A) and Pressurizer spray valves to open, decreasing actual RCS pressure. The RO will diagnose the pressure malfunction from alarms, meter indications, and decreasing Pressurizer pressure. The RO must close the PORV or PORV block valve to stop the pressure decrease. Manual action will also be required to close the Pressurizer spray valves which will open due to the master pressure controller demand. The SRO will implement and direct actions of 1BOA INST-2, FAILED INSTRUMENT CHANNEL Attachment B to select an operable controlling channel and restore automatic pressurizer pressure control, trip required bistables, and identify Technical Specification Action requirements 3.3.1 Reactor Trip System Instrumentation Conditions E and K - trip channel within 6 hrs., 3.3.2 Engineered Safety Feature Actuation System Instrumentation Condition D - trip channel within 6 hrs., 3.3.4 Remote Shutdown System Condition A - Restore within 30 days, 3.4.1 DNB Limits Condition A -

Restore DNB within 2 hrs.

Following completion of actions for controlling Pressurizer pressure channel (1PT-455) failing high, the 1C S/G controlling steam flow channel (1FT-532) will fail low, resulting in indications of decreased steam flow and initial closing of 1C S/G Feedwater regulating valve to attempt to match feed flow with steam flow. S/G level will decrease and manual control of the feedwater regulating valve will be required to maintain normal level. The crew will perform the actions of 1BOA INST-2, FAILED INSTRUMENT CHANNEL-Attachment H.

After the unit is stabilized following the Steam Flow channel malfunction, breaker 1592 trips causing a loss of 6.9KV Bus 159. No ABT to the Unit Auxiliary Transformer (UAT) will occur, resulting in a loss of the 1D RCP. The Reactor Protection System will sense the loss of RCS flow and generate a reactor trip signal. The Reactor will fail to trip (ATWS), requiring manual rod insertion due to auto rod speed failed at 8 steps per minute, and emergency boration.

1BFR S.1, RESPONSE TO NUCLEAR POWER GENERATION / ATWS will be entered. After dispatching an operator to locally trip Unit 1 reactor, the reactor trip breakers will be opened only after placing the steam dumps in Off/Reset per step 7 of BFR S.1.

After the Reactor is tripped, a LOCA of 500 gpm occurs. The size of the LOCA will require SI actuation, cold leg injection valves 1SI8801A&B will fail to open. 1SI8801B must be opened manually from the MCB. The LOCA will increase to 400,000 GPM over 2 minutes after 1SI8801B is open.

CS will fail to automatically occur at the high-3 pressure setpoints. Manual action by the crew will be required to actuate train B of CS, either while performing the actions of 1BEP-0 or the SRO may elect to perform 1BFR Z.1, RESPONSE TO HIGH CONTAINMENT PRESSURE The scenario ends with completion of Step 6 of 1BEP-1 or Step 6 1BEP ES-1.3 Scenario EPlan classification is MS-3 Critical Tasks

1. FR-S.1--C Insert negative reactivity into the core by manually inserting RCCAs before completing step 4 of 1BFR-S.1
2. FR-S.1--A Manually trip the main turbine in 1BFR-S.1
3. EP-0--I Manually initiate high head injection flow via 1SI8801B before exiting 1BEP-0
4. EP-0--E:

Manually actuate at least the minimum required compliment of containment cooling equipment before an extreme (red path) challenge develops to the containment CSF

Byron 2003-301 3

Scenario 03-1

Byron 2003-301 4

Scenario 03-1 SIMULATOR OPERATOR NOTES:

Simulator Setup:

IC-21, 100% power. Hang YELLOW risk placard.

Ensure Delta I limits and Delta I band are correct for IC.

Ensure Steam Flow Channel 1FT-532 is select as controlling channel on 1C SG Take 1A CS pump OOS. Control switch to PULL OUT. Hang Tag Hang Tags on 1CS007A, 1CS019A, 1CS001A, 1CS009A Take 1C HD pump OOS. Control switch to PULL OUT. Hang Tag.

With the simulator running, in an expert window type cae d:\\byron\\2003_demos\\nrc1a.cae Ensure the following appear on the summary popup:

mf rp02a Failure of Reactor Trip Breakers to open in Auto and Manual mf rp02b Failure of Reactor Trip Breakers to open in Auto and Manual mf cs01a Failure of 1A CS Pump mf fw35c Failure of 1C HD pump mf ed06d Breaker 1591 fails to ABT rf ed053i open Breaker for 1SI8801A When used with the light overrides it appears the Valve is closed and energized.

If operators are dispatched to de-energize and open this valve, then use the Overrides to de-energize the valve, but do NOT open 1SI8801A.

or zlo1si880101 on 1SI8801A close light on or zlo1si8801A1 on 1SI8801A close light on rf rp75 out 1SI8801B will not auto stroke open on an SI 1CV8105 will not auto close 1B AFW pump LO pump wont auto start will not affect scenario as the AF Pump will still auto start rf ed062a open Breaker for1CS007A rf ed053m open Breaker for 1CS019A rf ed053a open Breaker for 1CS001A rf ed053b open Breaker for 1CS009A rf ed071g open Breaker for 1CS007B rf ed025 open DC Bus 111 feed to Inverter 113 or zdi1cs001a cls 1CS001A CS to close or zlo1cs007b1 on 1CS007B close light on Ensure the following triggers are setup:

Trigger 3 cs:7bxb.eq.1.and. zdi1cs007b(2).eq.1 command: mrf ed071g close trigger 4 csv1cs007b.gt.0.1 command dor zlo1cs007b1 This will require the candidate to place the 1B CS pump to PTL, wait 30 seconds and open 1CS007B then restart 1B CS Pump to establish flow to containment.

Trigger 6 siv1si8801b.eq. 1 command mmf th06a 400000 120

Byron 2003-301 5

Scenario 03-1 Preload Annunciator 1-4-C5 Failure of DC input to inverter 113 Acknowledge on request actions to prepare for placing inverter 113 on CVT.

Event 1 Load Ramp to 1000 Mwe As SM acknowledge ramp initiation.

As Radiation Protection/Chemistry acknowledge sample requirements for power change > 15% in one hour.

Event 2 Pressurizer Pressure Channel 1PT-455 failure high (2500#) (When RO in position to respond)

IMF RX21A, 2500 over 30 second ramp Initiate malfunctions after load ramp complete and with concurrence of lead examiner.

Role Play as U-2 assist/extra NSO to accomplish bistable tripping.

Acknowledge all info passed as SM, WEC, and maintenance.

Perform the following to trip Pressurizer channel bistables:

On SDG RX10:

Open Protection Cabinet Door #1 RX020 OPEN Pzr Press Hi Trip PB455AC1-153 BS-1 RX032 TRIP Pzr Press Lo Trip PB455C C1-153 BS-4 RX034 TRIP Pzr Lo Press SI PB455DC1-153 BS-3 RX035 TRIP Pzr Press P-11 PB455B C1-153 BS-2 RX033 TRIP On SDG RX4:

OTDT Trip TB411CC1-124 BS-3 RX013 TRIP OTDT Runback TB411DC1-124 BS-4 RX135 TRIP Protection Cab #1 Close Door RX020 CLOSE Event 3 Steam Flow Transmitter 1FT-532 (controlling channel) fails LOW Insert malfunction to fail 1C SG controlling steam flow channel, 1FT-532 LOW (RX03E, 0 180 second ramp) on SDG RX16 after bistables for Pressurizer channel 1PT-455 are tripped. or at the lead examiners cue.

Event 4 Automatic Rod Motion fails at 8 Step per Minute (RD09, 8)

Insert Rod Speed Failure Malfunction (RD09, 8) immediately prior to inserting the Loss of Bus 159 Event 5 Loss of Bus 159 and ATWS Initiate Major Accident sequence after the actions are completed for the failed steam flow transmitter, or at the lead examiners cue.

Event 6 Reactor Trip Breakers fail to open (ATWS)

The ATWS malfunction(s) are in Pre-load. If directed as a local operator to open the unit 1 reactor trip breakers prior to stream dumps being placed in OFF/RESET, wait until after the steam dumps have been placed in OFF/RESET. otherwise wait 1 minute then DELETE malfunctions RP02A and RP02B and modify Remote Functions RP01 & RP02 to TRIP to open the Reactor Trip Breakers Acknowledge direction to perform step 10c if 1BFR S.1 as NLO Acknowledge the call for the STA to monitor Status Trees.

Acknowledge all info passed to the SM, WEC, and maintenance.

Insert LOCA malfunction (TH06C, 500 gpm) at step 15 of BFR S.1

Byron 2003-301 6

Scenario 03-1 Event 7 LOCA inside Cnmt. Leads to failure of Hi-3 automatic actuations Ensure trigger set up to increase LOCA size upon 1SI8801B opening.

If asked for ETR on 1A CS, report 2-4 hours is optimistic.

Acknowledge direction to trip Control Room Vent fans as NLO Wait 2 minutes and report Control Room Vent fans have been tripped Acknowledge direction to energize SVAG valves per 1BEP 0 step 16b After CAEPs have finished running, report the SVAG valves have been energized USE CAEP bep0step16b2a to energize valves.

INSTRUCTOR NOTE: As STA, do NOT report on any status until AFTER containment pressure has decreased below 20 psig.

Event 8 Failure of CS to automatically actuate The failure of CS to auto actuate is in the Pre-load. Operators will manually align the CS system for operation.

Comments:

Byron 2003-301 7

Scenario 03-1 Scenario No:

03-1 Event No.

1 Event

Description:

Ramp down turbine and reactor power to 1000 MWe.

Time Position Applicants Actions or Behavior CUE Turnover. 100% power. 1A Containment Spray Pump (CS) is OOS for a pump bearing replacement. 1C Heater Drain pump (HD) is OOS for an alignment and vibration problem. Ramp Unit to 1000 Mwe @

5MW/min Annunciator:

1-4-C5 BUS 113 INVERTER TROUBLE Note: A portion of the power increase preparations may have been performed in the briefing room US Refer to Tech Specs, and determine the following:

 3.8.7 Electrical Power Systems Inverters-Operating Condition A - Restore inverter in 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

Implement actions of 1BGP 100-4, rev 25, step F.1 (OR per 1BGP 100-4T2)

US Direct load reduction to 1000 MWe at 5 MW/min

 Initiate load swing instruction sheet, 1BGP 100-4T2

 Contact Chemistry and HP for load change >15% in one hour

 Perform Reactivity Briefing CREW Review applicable Prerequisites, Precautions, Limitations and Actions of 1BGP 100-4

Comments:

Byron 2003-301 8

Scenario 03-1 Scenario No:

03-1 Event No.

1 Event

Description:

Ramp down turbine and reactor power to 1000 MWe.

Time Position Applicants Actions or Behavior RO Verify rod position and boron concentration Initiate boration, if required. (BOP CV-6)

 Determine required boric acid volume

 Effects of previously performed borations

 Boration / Dilution tables IF BATCH addition desired:

 Determine the desired change in RCS Tave

 Determine required gallons of boric acid to change Tave IF Calculated addition desired:

 Determine required gallons of boric acid to increase RCS boron as desired NOTE: The remaining steps will be performed for either method of boration

 Determine required boric acid flow rate

 Set 1FK-110 BA Flow Control to desired boration rate (may leave at current value if Batch method used)

 Set 1FY-0110 BA Blender Preset Counter to desired volume.

 Place MAKE-UP MODE CONT SWITCH to stop position

 Set MODE SELECT to bor position

 Place MAKE-UP MODE CONT SWITCH to start

 Verify proper operation of valves and BA transfer pump (1CV110B open, 1CV110A throttles open, Boric Acid Pump running, Boric Acid flow indicated on recorder.)

BOP Initiate turbine load reduction:

 Depress LOAD RATE MW/MIN

 Enter desired value for rate (5 MW/min)

 Depress ENTER

 Depress REF

 Enter desired final turbine loading (1000 MW)

 Depress ENTER

 When ready to begin load decrease, depress GO

 Verify load reduction occurring

Comments:

Byron 2003-301 9

Scenario 03-1 Scenario No:

03-1 Event No.

1 Event

Description:

Ramp down turbine and reactor power to 1000 MWe.

Time Position Applicants Actions or Behavior RO/BOP Monitor reactor power and load decrease

 Monitor Nuclear instruments, Tave, I, Pressurizer press/level

 Monitor MWe, turbine loading, EHC RO During Boration:

 Monitor VCT level and pressure

 Monitor Boric Acid blender counter

 Verify boration stops at preset value NOTE: Following clearly observable plant response from the reactivity changes and with the concurrence of the lead examiner, the next event may be initiated.

Comments:

Byron 2003-301 10 Scenario 03-1 Scenario No:

03-1 Event No.

2 Event

Description:

PT-455 Controlling Pressurizer Pressure Channel fails high Time Position Applicants Actions or Behavior CUE Annunciators:

1-12-B2 PZR PORV OR SAF VLV OPEN 1-12-C6 PZR PORV DSCH TEMP HIGH 1-12-D2 PZR PRESS CONT DEV HIGH PORV 1RY455A OPEN Position indicating light lit.

1PI-455 Indicating 2500 psig.

Pressurizer pressure decreasing RO Diagnose/Announce Pressurizer pressure transmitter failure, 1RY455A and Pressurizer sprays open:

 Determine Pressurizer pressure is decreasing, identify open PORV and spray valves

 Stop the Depressurization o Place Master Pressurizer pressure controller in manual and decrease o Close 1RY455A o Close 1RY8000A

 Manually:

o Close spray valves.

o Control Master Pressurizer pressure controller US Implement and direct actions of 1BOA INST-2 OPERATION WITH A FAILED INSTRUMENT CHANNEL, ATTACHMENT B, PZR PRESSURE CHANNEL FAILURE:

 Identify failed Pressurizer pressure channel 1PT455

 Get acknowledgements from RO and BOP.

 Recognize Technical Specification entry for DNB LCO

 Inform SM of plant status, evaluate for E-Plan.

 Direct WEC to write WR, CR, and get maintenance involved.

 Direct holding the ramp and boration US

 Briefs Unit 1 NSO and Unit 2 assist NSO on bistable tripping.

Comments:

Byron 2003-301 11 Scenario 03-1 Scenario No:

03-1 Event No.

2 Event

Description:

PT-455 Controlling Pressurizer Pressure Channel fails high Time Position Applicants Actions or Behavior RO Perform actions of 1BOA INST-2 as directed:

 Determine Pressurizer Pressure not normal

 Take Manual Control to restore Pressure.

 Determine Operable Channel not selected

 Place the Master Pressurizer Pressure Controller in Manual

 Control Pressurizer Pressure

 Select an operable channel.

 Check Pressurizer PORVs, Spray Valves and Heaters:

 PORVS Closed.

 Pressurizer Spray valves normal. If not, then manually control.

 Pressurizer Heaters normal.

 Check Pressurizer Pressure Control in automatic:

 1RY455A returned to automatic.

 1RY456 in automatic.

 Sprays in automatic (after operable channel selected for control).

 Master Pressurizer Pressure Controller in automatic.

 Select operable channels to Recorders:

 Pressurizer Pressure.

 Loop DeltaT.

 Coordinates bistable tripping:

o Places colored dots on bistable, indications, and annunciators.

o Maintains communications with NSO tripping bistables.

RO/BOP Ensures the following Bistables are tripped: (May wait to trip bistables, have 6 hrs to complete)

 PB455A

 PB455C

 PB455D

 PB455B

 TB411C

 TB411D

 Checks Pressurizer Pressure > 1930 psig and P-11 permissive is NOT Lit (Bypass Permissive 3.3).

Comments:

Byron 2003-301 12 Scenario 03-1 Scenario No:

03-1 Event No.

2 Event

Description:

PT-455 Controlling Pressurizer Pressure Channel fails high Time Position Applicants Actions or Behavior BOP Perform actions as directed:

 Assist RO in monitoring panels and parameters.

 Investigate BARs.

 Make phone calls as directed to WEC and maintenance.

 Control load ramp US Refer to Tech Specs, and determine the following:

 3.3.1 Reactor Trip System Instrumentation Conditions E and K - trip channel within 6 hrs.

 3.3.2 Engineered Safety Feature Actuation System Instrumentation Condition D - trip channel within 6 hrs.

 3.3.4 Remote Shutdown System Condition A - Restore within 30 days

 3.4.1 DNB Limits Condition A - Restore DNB within 2 hrs.

NOTE: after completion of all actions and TS determination for the Pressurizer Instrument failure, and with the concurrence of the lead examiner, the next event may be initiated

Comments:

Byron 2003-301 13 Scenario 03-1 Scenario No:

03-1 Event No.

3 Event

Description:

Steam Flow Transmitter FT-532 (controlling channel) fails low EVENT NOT USED FOR THIS CREW Time Position Applicants Actions or Behavior CUE Annunciators:

1-15-C3 SG 1C FLOW MISMATCH STM FLOW LOW 1-15-C9 SG 1C LEVEL DEVIATION HIGH LOW 1FI-532 indication reading low 1FW530 throttling closed FW flow decreasing SG level decreasing below program BOP/US Identify/report steam flow channel 1FT-532 failure

 Take manual control of 1FW530 and increase feed flow above steam flow to restore level as necessary.

 Balance feed flow with steam flow to stabilize level as necessary.

 Take manual control of Master FW Pump Speed controller to establish adequate Feedwater pump Delta P US Implement and direct actions of 1BOA INST-2, OPERATION WITH A FAILED INSTRUMENT CHANNEL, Attachment H STEAM FLOW CHANNEL FAILURE:

 Get acknowledgements from RO and BOP.

 Inform SM of plant status, evaluate for E-Plan.

 Direct WEC to write WR, CR, and get maintenance involved.

 Direct holding load decrease BOP Perform actions as directed:

 Check affected SG levels normal. IF NOT:

 Place FRV in Manual

 Verify/establish adequate Feedwater pump Delta P

 Restore level to a stable condition.

 Select operable Steam flow channel

 Establish automatic level control

 Verify Steam Pressure channels normal

 Verify/restore Feedwater speed control in automatic RO Assist BOP as required to identify failed instrument channel and stabilize SG levels Monitor RCS and stabilize changing parameters resulting from feed flow/steam flow imbalance:

 RCS Tave

 Pzr Pressure

 Boration

 Load decrease

Comments:

Byron 2003-301 14 Scenario 03-1 Scenario No:

03-1 Event No.

3 Event

Description:

Steam Flow Transmitter FT-532 (controlling channel) fails low EVENT NOT USED FOR THIS CREW Time Position Applicants Actions or Behavior NOTE: Following the actions for the failed Steam flow channel and with the concurrence of the lead examiner, the next event may be initiated.

Comments:

Byron 2003-301 15 Scenario 03-1 Scenario No:

03-1 Event No.

4,5,6 Event

Description:

Loss of 6.9 KV Bus 159 no ABT resulting in a partial Loss of Flow ATWS. During ATWS Auto Control rod speed fails to 8 spm.

Time Position Applicants Actions or Behavior CUE Annunciators:

1-20-A6 BUS 159 Fd BRKR 1592 TRIP 1-20-D6 BUS 159 VOLT LOW 1-13-A2 RCP BUS UNDERVOLTAGE RX TRIP ALERT 1-13-D3 RCP 1D BRKR OPEN OR LOW FLOW ALERT 1-13-E3 RCP TRIP 1-11-A4 OPDT RX TRIP 1-11-C5 RCP LOW FLOW ABOVE P8 RX TRIP No voltage on Bus 159:

Loop 1D RCS flow coasting down Inward rod motion demanded at only 8 steps per minute.

CREW Diagnoses loss of Bus 159, 1D RCP, and RED First Out dictating need for Reactor Trip, but failure of Automatic Trip to occur.

US Implement and direct actions of 1BEP-0 "REACTOR TRIP OR SAFETY INJECTION" RO/BOP Perform immediate operator actions of 1BEP-0 Determine the reactor is not tripped:

 Rod bottom lights not lit

 Reactor trip & bypass breakers not open

 Neutron flux not decreasing Manually attempt to trip reactor with both switches at:

 1PM05J

 1PM06J RO Identify/report that reactor trip breakers did not open.

US Implement and direct actions of 1BFR-S.1 "RESPONSE TO NUCLEAR POWER GENERATION/ATWS"

 Contact WEC for STA duties NOTE: Crew may dispatch operator to locally open reactor trip breakers at any time.

Comments:

Byron 2003-301 16 Scenario 03-1 Scenario No:

03-1 Event No.

4,5,6 Event

Description:

Loss of 6.9 KV Bus 159 no ABT resulting in a partial Loss of Flow ATWS. During ATWS Auto Control rod speed fails to 8 spm.

Time Position Applicants Actions or Behavior RO Perform immediate operator actions of FR-S.1:

 Verify reactor is not tripped

 Rod Bottom lights not lit

 Reactor trip breakers not open; Bypass breakers open (not racked in)

 Neutron flux not decreasing from Post Trip.

 Manually attempt to trip reactor with both switches at:

 1PM05J

 1PM06J RO

[CT]

FR-S.1--C Insert control rods at 48 spm in Manual. (automatic is failed to 8 spm)

BOP

[CT]

FR-S.1--A Verify turbine trip

 Turbine throttle valves not closed

 Turbine governor valves not closed

 Manually trip turbine Check AFW Pumps Running

 AFW Pump run lights not lit

 Manually start AFW pumps RO/BOP Initiate Emergency Boration of RCS

 Check at least one centrifugal charging pump running

 Open 1CV8104

 Start boric acid transfer pump

 Check emergency boration flow - GREATER THAN 30 GPM

 Verify charging flow - GREATER THAN 30 GPM RO Check Pressurizer pressure - Less than 2335 psig BOP Verify Containment Ventilation Isolation

 Group 6 Containment Vent Isolation monitor lights lit

Comments:

Byron 2003-301 17 Scenario 03-1 Scenario No:

03-1 Event No.

4,5,6 Event

Description:

Loss of 6.9 KV Bus 159 no ABT resulting in a partial Loss of Flow ATWS. During ATWS Auto Control rod speed fails to 8 spm.

Time Position Applicants Actions or Behavior RO Verify reactor subcritical

 PR channels < 5%

 IR channels SUR < 0 Determine the power is still above 5% and continue with steps of 1BFR-S.1.

BOP Isolate Steam Dumps

 Place steam dump BYPASS INTERLOCK switches to OFF/RESET for both trains.

NOTE: Reactor trip breakers will be locally opened after dumps are in OFF/RESET.

CREW Check trips have occurred

 Reactor trip.

 Turbine trip BOP Check SG levels

 Level in at least one SG > 10% if not, verify > 900 gpm AFW flow

 Control feed flow to maintain SG levels between 10% (31% adverse) and 50%

 Check SG blowdown isolation valves closed: 1SD002A-H RO Verify all dilution path valves closed

 Reactor Makeup dilution valves 1CV111A and 1CV111B closed

 Verify BTRS Mode Selector in off

 Dispatch operator to locally check valves closed per 1BFR S.1 step 10c CREW Stop reactivity insertion from RCS cooldown

 RCS temperature not decreasing in uncontrolled manner

 SG pressure, none decreasing in uncontrolled manner RO Check CETCs < 1200F NOTE: 500 gpm LOCA will start here RO Verify reactor subcritical

 PR channels < 5%

 IR channels SUR < 0

Comments:

Byron 2003-301 18 Scenario 03-1 Scenario No:

03-1 Event No.

7,8 Event

Description:

LOCA / Failure of CS to actuate Time Position Applicants Actions or Behavior CUE Annunciators:

1-1-A2 CNMT DRAIN LEAK DETECT FLOW HIGH Pressurizer pressure decreasing Pressurizer level decreasing Containment pressure increasing US Implement and direct the actions of 1BEP-0 REACTOR TRIP OR SAFETY INJECTION o

Get acknowledgements from RO and BOP.



Informs SM of plant status for evaluation of E-Plan RO Perform Immediate Actions of 1BEP-0 Verify reactor trip

 Rod bottom lights lit

 Reactor trip and bypass breakers open

 Flux decreasing BOP Verify Turbine tripped

 All throttle valves closed

 All governor valves closed Verify 4KV ESF Busses energized

 Bus 141 bus alive light lit

 Bus 142 bus alive light lit CREW Determine SI needed/actuated:

 SI First Out Annunciator lit (1-11-B/C/D/E1)

 SI ACTUATED lit (1-BP-4.1)

 SI Equipment actuated

 Manually Actuate SI CREW (If manual SI not previously performed) Recognize and respond to conditions requiring a Safety Injection in accordance with 1BEP-0 REACTOR TRIP OR SAFETY INJECTION, Step 4:

 Pressurizer pressure cannot be maintained > 1829 psig

 Pressurizer level cannot be maintained > 4%

 Manually initiate SI

Comments:

Byron 2003-301 19 Scenario 03-1 Scenario No:

03-1 Event No.

7,8 Event

Description:

LOCA / Failure of CS to actuate Time Position Applicants Actions or Behavior BOP/US Verify Feedwater isolation:

 FW pumps tripped

 Isolation monitor lights lit

 FW discharge valves (1FW002A/B/C) closed RO/US NOTE: 1SI8801B may be opened at this point while verifying pump alignments (CT on page 20)

Verify ECCS pumps running:

 CV pumps

 SI pumps

 RH pumps BOP/US Verify Containment Conditions:

 RCFC Accident Mode lights lit (Group 2)

 Phase A lights lit (Group 3)

 Containment Ventilation lights lit (Group 6)

BOP/US Verify the following:

 AFW Aligned:

 1A and 1B AFW pumps running

 1AF013A-H open

 1AF005A-H throttled

 1A and 1B CCW pumps running

 1A and 1B SX pumps running

 Main Steam isolation valves and Main Steam isolation bypass valves isolated when Containment pressure

>8.2 psig NOTE: RCP Trip criteria may be met at this point RO/BOP Determine if RCPs meet trip criteria

 Controlled cooldown not in progress

 RCS pressure <1425 psig

 High head SI flow indicator (1FI-917) >100 gpm or SI pump discharge flow >200 gpm

 Trip RCPs

Comments:

Byron 2003-301 20 Scenario 03-1 Scenario No:

03-1 Event No.

7,8 Event

Description:

LOCA / Failure of CS to actuate Time Position Applicants Actions or Behavior BOP/US

[CT]

EP-0E NOTE: This sequence may not happen until the size of the LOCA is increased.

Check If Containment Spray required:

 Containment pressure > 20 psig

 Group 6 lights NOT lit Identifies/reports B Train of CS not operating properly

 Manually actuates both switches for CS and Phase B actuation at 1PM05J and 1PM06J

 Determines manual actuation unsuccessful. Performs Attachment B. (Train A CS is OOS)

 1CS001B open

 1CS007B closed

 Places 1B CS pump PULL OUT

 Verify TEST switch to normal

 Opens 1CS007B after 30 second time delay

 Restarts 1B CS pump

 Verify 1CS019B open

 Verify 1CS010B open

 Verify 1 CS pump running

 Phase B lights Lit

 Stop All RCPs

 Verifies Eductor Suction flow > 15 gpm (1FI-CS014)

 Verifies CS Additive flow > 5 gpm (1FI-CS016)

BOP Align SX Cooling Towers

 All eight riser valves open

 0SX163A thru 0SX163H

 All four Hot Water Basin Bypass valves closed

 0SX162A thru 0SX162D

 All eight SX Cooling Tower Fans running in high speed.

BOP Verify Total AFW flow:

 AFW flow > 500 gpm

 SG levels maintained between 10% (31% Adverse) and 50%

 SG levels not increasing in an uncontrolled manner

Comments:

Byron 2003-301 21 Scenario 03-1 Scenario No:

03-1 Event No.

7,8 Event

Description:

LOCA / Failure of CS to actuate Time Position Applicants Actions or Behavior RO

[CT]

EP-0--I Verify ECCS valve alignment

 Group 2 Cold Leg Injection monitor lights lit - OPEN 1SI8801B

 Align SVAG Valve power switches and dispatch NLO to energize breakers ECCS Operations:

 High Head SI flow > 100 gpm

 RCS pressure < 1700 psig

 SI pump flow > 200 gpm

 RCS pressure < 325 psig o

RH pump flow > 1000 gpm Pressurizer PORV relief path available:

 At least one block valve energized

 PORV in automatic

 Associated block valve open BOP Verify Main Generator Trip:

 Output Breakers open

 PMG Breaker open EDGs running

 1SX169A and B open

 Dispatch operator for local check of EDG operation Examiners note: US and RO will likely continue in 1BEP-0 while BOP is performing the next 3 ventilation steps:

Comments:

Byron 2003-301 22 Scenario 03-1 Scenario No:

03-1 Event No.

7,8 Event

Description:

LOCA / Failure of CS to actuate Time Position Applicants Actions or Behavior BOP Verify Control Room ventilation aligned for emergency operations:

 Dispatch NLO to trip VV supply fans

 Operating VC train equipment running

 Supply fan

 Return fan

 M/U fan

 Chilled water pump

 MCR chiller 0A running

 Operating VC train dampers

 M/U fan outlet damper not full closed 0VC24Y

 VC train M/U filter light lit

 Operating VC train Charcoal Adsorber aligned for train A

 0VC43Y closed

 0VC21Y open

 0VC22Y open

 Control Room pressure greater than +0.125 inches water on 0PDI-VC038 BOP Verify Auxiliary Building ventilation aligned

 Two inaccessible filter plenums aligned

 Plenum A fan 0VA03CB running

 Damper 0VA023Y open

 Damper 0VA436Y closed

 Plenum C fan 0VA03CF running

 Damper 0VA072Y open

 Damper 0VA438Y closed BOP Verify FHB ventilation aligned

 Train B fan 0VA04CB running

 0VA055Y open

 0VA062Y open

 0VA435Y closed RO/US Check Pressurizer sprays & PORVs closed

 Normal spray valves closed 1RY455B and 1RY455C

 PORVs closed 1RY455A and 1RY456

Comments:

Byron 2003-301 23 Scenario 03-1 Scenario No:

03-1 Event No.

7,8 Event

Description:

LOCA / Failure of CS to actuate Time Position Applicants Actions or Behavior CREW Maintain RCS temperature control

 With any RCP running, RCS Tave stable at or trending to 557 degrees F.

 With No RCP running, RCS Cold Leg temperature stable at or trending to 557 degrees F.

CREW Check status of RCPs

 Determine if RCPs are running.

 Check if RCPs should be stopped:

 ECCS flow-high head > 100 gpm; or SI pump > 200 gpm.

 RCS pressure < 1425 psig.

 Controlled cooldown NOT in progress, nor previously initiated.

 Stop All RCPs.

BOP/CREW Check Secondary Pressure Boundaries are intact

 No SG pressure decreasing in uncontrolled manner

 No SG completely depressurized BOP/CREW Check SG tube intact

 No abnormal secondary radiation BOP/CREW Check RCS intact

 Containment area radiation monitors > alert alarm setpoints

 Containment pressure > 3.4 psig

 Containment sump level lights lit US Implement and direct actions of 1BEP-1, LOSS OF REACTOR OR SECONDARY COOLANT o Get acknowledgements from RO and BOP.

 Informs SM of plant status for evaluation of E-Plan RO Check RCPs

 No RCPs running

Comments:

Byron 2003-301 24 Scenario 03-1 Scenario No:

03-1 Event No.

7,8 Event

Description:

LOCA / Failure of CS to actuate Time Position Applicants Actions or Behavior BOP Check SG Secondary pressure boundaries intact

 No SG Pressure decreasing uncontrollably

 No SG completely depressurized Check intact SG levels

 Narrow range levels > 10% (31% Adverse)

 Control Intact SG levels to 10% (31% Adverse) to 50% NR level

 Narrow range levels NOT increasing in uncontrolled manner Check Secondary Radiation levels normal

 No abnormal secondary radiation RO Check Pressurizer PORVs and isolation valves:

 PORV Isolation valves open and energized

 1RY8000A

 1RY8000B

 PORVs closed

 1RY455A

 1RY456 CREW Check if ECCS flow should be reduced:

 RCS Subcooling not acceptable

 Secondary heat sink acceptable

 RCS pressure decreasing

 Pzr Level <12%

Determine ECCS flow should NOT be reduced.

NOTE: Scenario Termination criteria is completion of step 6 of 1BEP-1 or step 6 1BEP ES-1.3 Scenario EPlan classification is MS-3 US Implement and direct actions of 1BEP ES-1.3, TRANSFER TO COLD LEG RECIRCULATION when RWST level < 46% (Actions on page 25)

Comments:

Byron 2003-301 25 Scenario 03-1 Scenario No:

03-1 Event No.

7,8 Event

Description:

LOCA / Failure of CS to actuate Time Position Applicants Actions or Behavior NOTE: At some time Containment pressure may rise to an ORANGE Path condition (without CS pumps running). If so, performance of 1BFR Z.1 RESPONSE TO HIGH CONTAINMENT PRESSURE may be required. Actions are covered below. CUE will be provided by the STA after monitoring the BSTs.

US Implement and direct as advised by the STA the actions of 1BFR-Z.1, RESPONSE TO HIGH CONTAINMENT PRESSURE.

o Get acknowledgements from RO and BOP.

 Inform SM of plant status for evaluation of E-Plan BOP Verify Containment isolations

 Phase A Group 3 lights lit

 Containment Ventilation Group 6 lights lit Check if Containment Pressure has increased to > 20 psig (1PR-937 or 1PI-CS934 thru 937)

 Stop all RCPs (previously completed)

Verify CS alignment: (previously complete for B Train)

US/BOP Verify Group 6 Phase B isolation lights lit (previously completed)

Verify RCFCs running in accident mode (Group 2 lights lit).

Verify Main Steam Isolation

 Main Steam isolation valves and Main Steam isolation bypass valves closed. (previously completed)

Determine NO SGs are faulted:

 No Steam Generator pressure decreasing in an uncontrolled manner

 No Steam Generator completely depressurized Return to step and procedure in effect.

Comments:

Byron 2003-301 26 Scenario 03-1 Scenario No:

03-1 Event No.

7,8 Event

Description:

LOCA / Failure of CS to actuate Time Position Applicants Actions or Behavior NOTE: ACTIONS FOR 1BEP ES-1.3, TRANSFER TO COLD LEG RECIRCULATION BOP/RO Perform actions of 1BEP ES-1.3 as directed:

Check CC pumps 2 running Open CC to RH Heat exchanger isolation valves

 1CC9412A and 1CC9412B Check CC flows to RH Heat exchanger

 >5000 gpm Verify adequate Containment sump level

 Bottom 4 lights lit Align RH pump suctions to Containment sumps:

 Place control switches for SVAG valves 480 bus feeds in close

 Check Both RH pumps running

 Check open 1SI8811A and 1SI8811B

 Close 1SI8812A and 1SI8812B Check SI and CV pumps in injection mode:

 SI pumps both running

 Cold Leg Injection valves (1SI8801A/B) open Align SI and CV pumps for Cold Leg Recirculation:

 Dispatch operator to energize 1SI8806 and 1SI8813

 Verify CV pump 1A miniflow isolation valves closed

 1CV8111 and 1CV8114

 Close SI pump miniflow isolation valves

 1SI8814, 1SI8920, and 1SI8813 when power restored

 Close RH Heat exchanger Discharge Cross ties

 1RH8716A and B

 Open SI and CV pump suction header Cross ties

 1SI8807A and B, and 1SI8924

 Check 1A RH pump running

 Open 1CV8804A

 Check 1B RH pump running

 Open 1SI8804B Start ECCS pumps as necessary (NOTE: Scenario may be terminated at this point)

Byron 2003-301 1

Scenario 03-2 Simulation Facility Byron Scenario No. 2 Operating Test No. 2003-301 Examiners:

Applicant:

SRO RO BOP Initial Conditions:

IC-18, 75% power, steady state, BOL.

Turnover: Ramp to full power requested by Electric Operations. 1A Motor driven FW is out of service due to breaker cubicle work.

Event No.

Malf. No.

Event Type*

Event Description Preload RF RP64 OUT RF RP71 OUT RF RP95 OUT RF RP97 OUT FW43 MS01A 75 MS01B 80 MS01C 60 MS01D 90 FW45E, 100 Override ZDI1AF013E AUTO C BOP C BOP C RO BOP SRO C BOP C BOP SRO 1B Auxiliary Feedwater pump fails to auto start, can be manually started.

1A Auxiliary Feedwater pump fails to auto or manually start.

All Main Steam isolation valves fail partially open, no closure available.

1AF005E potentiometer fails to 100% demand.

1AF013E stuck open.

1 R RO SRO N BOP Raise Reactor Power using rods and dilution Ramp up turbine power from 75% to full power.

2 RX29A 65 PN0610 on C BOP SRO Steam Generator 1A Feedwater regulating valve Controller card failure resulting in manual control of Feedwater regulating valve 3

3A RX13A, 0 I RO SRO N BOP 1LT-459, Controlling Pressurizer level channel fails low.

Restore Letdown 4

CV09, 50 C RO SRO 1TCV-130A modulates closed 5

MS04D, 100 C BOP SRO 1MS018D, 1D SG PORV fails open.

6 CC03B CC01C CC02A I BOP SRO Component Cooling (CC) Surge Tank level transmitter level tree leak results in auto makeup and 1B CC pump trip with failure of 1A CC pump auto start on low header pressure.

7 MS07A, 2.0 (Pre-loaded)

M BOP RO SRO 1A SG Steam line break (2 MLB/HR) inside containment. 4 faulted steam generators.

All MSIVs fail to Close. Stuck open 8

1A and 1B AFW pumps fail to Start C BOP SRO Pre-loaded. 1A Auxiliary Feedwater pump fails to start. 1B Auxiliary Feedwater pump can only be manually started.

Byron 2003-301 2

Scenario 03-2

  • (N)ormal, (R)eactivity (I)nstrument, (C)omponent, (M)ajor Transient

Byron 2003-301 3

Scenario 03-2 SCENARIO OVERVIEW The scenario begins with the plant at 75% power and a ramp to full power @ 5 MW/Min is requested via the turnover. The turnover includes information that the 1A Motor driven FW pump is out of service for breaker cubicle work.

After the requested reactivity change, 1A Steam Generator Feedwater regulating valve 1FW510 controller will experience a card failure requiring the operator to manually control. The operators will need to monitor 1A feedwater flow during the requested load change and the rest of the scenario. The BOP will diagnose the failure and manually control the 1A S/G feed regulating valve.

Following the failure of 1A SG regulating valve controller failure, a failure of the controlling channel of Pressurizer level will occur causing letdown to isolate. The crew will respond by diagnosing the failure of the level channel and entering and performing the actions of 1BOA INST-2 Attachment C, OPERATION WITH A FAILED INSTRUMENT - PRESSURIZER LEVEL CHANNEL FAILURE. An alternate controlling level channel will be selected, letdown will be restored, and the crew will take actions to restore pressurizer level to the program value. Bistables will be tripped for the failed channel, and Technical Specifications will be investigated. LCO 3.3.1 condition K will apply. Maintenance will investigate as requested.

Following the restoration of letdown and bistable tripping, the transmitter for 1TI-130 Letdown heat exchanger outlet temperature controller fails low causing actual letdown temperature to increase resulting in a high temperature diversion around the mixed bed demineralizers. Manual control of the temperature controller is available and will be necessary to restore letdown temperature to normal. Annunciator response procedures will be referenced to respond to the failure.

When manual control of the letdown temperature control valve is selected, a 1D S/G PORV controller failure will cause the 1D S/G PORV to open. RCS Tave will decrease possibly causing control rod motion in the outward direction. The crew will investigate and diagnose the inadvertent PORV failure. Emergency closure of the PORV will be available from the control room and the PORV may be locally isolated if directed by the crew. The SRO will determine Technical Specification 3.7.4 applies.

A Component Cooling (CC) Water surge tank level tree leak will result in low level indication causing automatic makeup from demineralized water and automatic trip of the 1B CC pump. The 1A CC pump will fail to automatically start requiring the operators to manually start the pump. The crew should identify the failure and dispatch an operator to locally isolate demineralized water makeup to the surge tank. Local surge tank level indication is available and the crew should instruct local operations to drain the surge tank to normal level and address operability concerns for 1B CC pump. The SRO will determine Technical Specification 3.7.7 applies.

A 1A S/G Steamline break inside of containment will occur requiring a safety injection. 1BEP-0, REACTOR TRIP OR SAFETY INJECTION will be entered. Containment pressure will exceed the Containment Spray actuation setpoint. Manual action will be required to start the 1B Auxiliary Feedwater pump. The 1A Auxiliary Feedwater pump will fail to start. A diagnosis of a Faulted S/G will cause transition to 1BEP-2, FAULTED SG ISOLATION. Further diagnosis will determine 4 faulted S/Gs exist due to failure of all Main Steam isolation valves to close and a transition to 1BCA-2.1, UNCONTROLLED DEPRESSURIZATION OF ALL S/Gs will be made. Depending on the timing, a transition to 1BFR Z.1, RESPONSE TO CONTAINMENT HIGH PRESSURE, may occur after exiting the Reactor Trip/Safety Injection procedure. Manual operator action will be required to throttle AFW flow to a minimum to the SGs. Local operator action will be required to throttle B Train AFW flow to the faulted 1A S/G due to a failure of the potentiometer and a stuck open isolation valve. Containment Spray may be terminated (depending on the amount of secondary water inventory remaining in the SGs and the RCS temperature) before reaching the LO-2 RWST setpoint for automatic swap over to the containment sump and an unnecessary injection of sump water into the RCS. NaOH addition to the CS water could be stopped due to the break being on a secondary system. If the LO-2 RWST level is reached, then the crew will transition to 1BEP ES-1.3, TRANSFER TO COLD LEG RECIRCULATION and then back to the procedure and step in effect. The crew will proceed to terminate the safety injection in 1BCA 2.1. Scenario termination is completion of step 8 of 1BCA-2.1 or Entry into 1BEP ES-1.3 Scenario EPlan classification is HU2 Critical Tasks E-0F Establish the minimum required AFW flow rate to the SGs before transition out of E-0, unless the transition is to FR-H.1, in which case the task must be initiated before RCPs are manually tripped per FR-H.1.

ECA-2.1---A Control the AFW flow rate to not less than 45 gpm per SG in order to minimize the RCS Cooldown rate before a severe (orange path) challenge develops to the integrity CSF.

Byron 2003-301 4

Scenario 03-2 SIMULATOR OPERATOR NOTES:

Simulator Setup:

Init IC 18, BOL, Xenon equilibrium, steady state.

Ensure 1B CC pump is running and 1A CC pump in standby With the simulator running, in an expert window type cae d:\\byron\\2003_demos\\nrc2.cae and verify the following:

Place 1A MFP control switch to Pull Out and hang tag.

RF RP64 OUT 1B AFW pump fails to auto start, can be manually started.

RF RP71 OUT RF RP95 OUT RF RP97 OUT IMF FW43 1A Auxiliary Feedwater pump fails to auto or manually start.

IMF MS01A 75, MS01B 80, MS01C 60, MS01D 90 open, no closure available.

IMF FW45E 100 1AF005E potentiometer fails at 100% demand.

IOR ZDI1AF013E AUTO 1AF013E stuck open.

Ensure Trigger 3 is setup as event zao1li676.lt. 0.15 command IMF CC01C trgset 4 "yp:mrx29a.eq. 1" command "imf pn0610 on" Event 1 Power ramp from 75% up to 100%.

As SM acknowledge ramp initiation.

As Radiation Protection/Chemistry acknowledge sample requirements for power change > 15% in one hour.

Event 2 Steam Generator 1A Feedwater regulating valve Controller card failure resulting in manual control of Feedwater regulating valve.

Acknowledge all info passed to the SM, WEC, and maintenance.

Trigger 4 will activate annunciator 1-4-A3. If dispatched to 1PA05J to investigate the Process I&C Cabinet Power Supply failure alarm report that no obvious problems are present.

Event 3 Controlling Pressurizer level channel fails low (1LT-459).

SDG:

RX6 Malf:

RX13A, 0 severity, no ramp.

Initiate at lead examiners cue.

Role play as U-2 assist and/or extra NSO to accomplish bistable tripping. Acknowledge all info passed to the SM, WEC, and maintenance.

SDG:

RX6 Cabinet door #1 Open RF RP20 OPEN Hi Level Trip LB459A C1-751 BS-1 RF RX029 TRIP Cabinet door #2 Close RF RP20 CLOSE Event 4 On line letdown heat exchanger (1A) Temperature transmitter for 1TI-130 fails low SDG:

CV2 and CC6 Initiate after Letdown temperature controller is placed back in automatic after event 3.

Malf:

CV09, 50 Intent is to cause operator to have to take manual control of the TCV-130 controller and restore letdown temperature without having to swap letdown heat exchangers. Manual control via the M/A station is available on this malfunction. Acknowledge all info passed to the SM, WEC, and maintenance. If dispatched as local operator, use first check and report no obvious problems at the valve. Valve appears to operate smoothly from local observation. Use Remote Function CC50 to reset Penetration Cooling alarm if dispatched.

Byron 2003-301 5

Scenario 03-2 Event 5 1D SG PORV 1MS018D, fails open.

SDG:

MS4 Initiate after letdown temperature is stabilized or at lead examiners cue.

Malf:

MS04D, 100, no ramp If dispatched to the controller box in the AEER, report no obvious problems. If dispatched to locally close 1MS019D, wait 5 minutes, use first check, and then use RF: MS54 CLOSE to close the isolation valve. Report 1MS019D closed when completed. Acknowledge all info passed to the SM, WEC, and maintenance. If asked, on-line risk is Yellow.

Event 6 Component Cooling (CC) Surge Tank level transmitter level tree leak results in auto makeup and 1B CC pump trip with failure of the 1A CC pump to auto start.

SDG: CC2 Malf: CC03B, 0 and CC01C and (CC02A at current value, preload)

Initiate event after actions for the Porv failure are complete or at lead examiners cue.

If dispatched as Aux NLO, report a leak on the level tree and local Surge tank levels indicate high and take actions as directed to isolate Demin water (WM) makeup to CC tank. The leak can be isolated.

If dispatched as Aux NLO, report that 1A CC pump is running normally.

Use Remote Function CC52 to close 1CC185, the manual isolation for demin water makeup to the CC surge tank 1CC183.

Acknowledge all info passed to the SM, WEC, and maintenance.

If directed,use first check, and use Remote Function CC15 to drain the surge tank If directed to isolate the leak report that you have closed 1CC9457A and 1CC9457B, level transmitter 676 isolation valves.

If directed to swap U0 CC pump to Bus 142 use remote functions CC42 RO and CC07 RI Event 7 Steam line break inside containment on 1A steamline.

Initiate events 7 and 8 after tech specs are investigated for the 1D SG PORV, or at the lead examiners cue.

Action:

SDG:

MS1 Malf:

MS07A, 2.0 Mlb/hr Acknowledge all info passed to SM, WEC, and others regarding reactor trip and SI and procedure transitions.

Acknowledge direction to trip Control Room Vent fans as NLO and monitoring of DG operations Wait 2 minutes and report Control Room Vent fans have been tripped Acknowledge direction to energize SVAG valves per BEP 0 step 16b After CAEPs have finished running, report the SVAG valves have been energized USE CAEP bep0step16b2a to energize valves.

Role play as STA when asked and monitor the Status Trees. Pay particular attention to the Containment Status Tree as the intent of the scenario is reach the Hi-3 setpoint. Actions in EP-0 will ensure Containment Spray is going, however if monitoring the Status Trees identifies an Orange path, report it to the US as usage rules apply.

If dispatched as local operators to check/investigate equipment, report as follows for the requested actions:

All running equipment is operating properly.

1A Auxiliary Feedwater Pump Breaker has an over current flag on phase C. Bus 141, cub 8.

Need the floor plugs removed to get to the 1AF013E.

SDG:

FW13 Use RF: FW161 to position the hand wheel for 1AF005E as requested. (8.5 will ~ 45 gpm)

Maintenance will attempt to locally close any/all MSIVs (but will be unsuccessful).

Byron 2003-301 6

Scenario 03-2

Comments:

Byron 2003-301 7

Scenario 03-2 Scenario No:

03-2 Event No.

1 Event

Description:

Raise turbine load and reactor power.

Time Position Applicants Actions or Behavior CUE Turnover information includes request from Electric Operations for an increase in Unit 1 MW to full load (1260 MWe) to begin ASAP at 5 MWe/minute.

Note: A portion of the power increase preparations may have been performed in the briefing room US Implement actions of 1BGP 100-3

 Initiate load swing instruction sheet (1BGP 100-4T2 Boration Dilution Boundary Calculation).

o Contact Chemistry and Health Physics for load change > 15% in one hr.

 Inform SM of plant Status, and Electric Operations of ramp start.

CREW Review Applicable Precautions, Limitations and Actions.

RO Verify rod position and boron concentration.

Perform reactivity manipulation calculation to determine amount of RCS dilution and expected rod outward movement to maintain Delta I within the limits of BCB-1 Fig. 19.

Determine required dilution volume by:

o Effects of previously performed dilutions.

o Byron Boration Dilution Tables.

Initiate Dilution in accordance with BOP CV5:

IF BATCH addition desired:

 Determine the desired change in RCS Tave

 Determine required gallons of primary water to change Tave IF Calculated addition desired:

 Determine required gallons of primary water to decrease RCS boron as desired NOTE: The remaining steps will be performed for either method of dilution

 Determine required primary flow rate

 Place MAKE-UP MODE CONT SWITCH to stop position

 Set MODE SELECT to dil or alt dil position

 Set 1FK-111 PW/Total Flow Control to desired flow rate (may leave at current value if Batch method used)

 Set 1FY-0111 PW/Total Flow Preset Counter to desired volume.

 Place MAKE-UP MODE CONT Switch to start.

 Verify proper operation of valves (1CV111A opens, 1CV111B opens, PW flow indicated on recorder).

Comments:

Byron 2003-301 8

Scenario 03-2 Scenario No:

03-2 Event No.

1 Event

Description:

Raise turbine load and reactor power.

Time Position Applicants Actions or Behavior BOP Initiate turbine load increase:

 Verify the DEHC IMP IN, SPEED IN, and MW IN half of the pushbuttons are illuminated.

 Depress the LOAD RATE MW/MIN pushbutton.

 Enter the desired load rate (5 MW).

 Depress the ENTER pushbutton.

 Depress the REF pushbutton.

 Enter the desired MW on the REFERENCE DEMAND Window using the numbered pushbuttons (1120).

 Depress the ENTER pushbutton.

 Depress the GO pushbutton when directed by the US/RO.

 Verify load begins to increase.

o Monitor 1A SG Level RO Monitor power increase:

 Monitor Reactor power, Tave, and Delta I.

 Verify control rods automatically move to maintain Tave within + 1.0 degree F of Tref.

If Diluting:

 Monitor VCT level.

 Monitor PW/Total counter.

 Verify dilution auto stops at preset value.

 Return Reactor Makeup system to blended flow at current boron concentration.

Note: Following clearly observable plant response from the reactivity changes and lead examiners concurrence, the next event can be initiated.

Comments:

Byron 2003-301 9

Scenario 03-2 Scenario No:

03-2 Event No.

2 Event

Description:

Steam Generator 1A Feedwater regulating valve automatic control card failure Time Position Applicants Actions or Behavior CUE Annunciators:

1-4-A3 PROCESS I&C CAB PWR SUP FAILURE 1-15-A9 STEAM GENERATOR 1A LEVEL DEVIATION HIGH LOW Increased Feed Flow to 1A SG Increasing 1A SG Level BOP Diagnose/Recognize failure of 1A Feedwater regulating valve Auto Controller.

 Announce placing 1A Feedwater regulating valve Controller in manual.

 Manually control 1FW510 to stabilize/restore level.

 Dispatch operator to 1PA05J to check for failure lights per BAR 1-4-A3 US Diagnose/Acknowledge failure of 1A Feedwater regulating valve Auto Controller.

 Orders WEC to generate WR, CR, and get maintenance involved for repairs.

RO Monitors Reactor and Primary parameters for possible effects:

 Reactor power and Delta I.

 Tave and control rod motion.

 Reports status to US.

Assists BOP as directed by US:

o Reviews BARs.

Note: Following actions from the failed controller and lead examiners concurrence, the next event may be initiated.

Comments:

Byron 2003-301 10 Scenario 03-2 Scenario No:

03-2 Event No.

3 Event

Description:

1LT-459 Controlling Pressurizer level channel fails LOW.

Time Position Applicants Actions or Behavior CUE Annunciators:

1-12-A4 PZR LVL LOW HTRS OFF LTDWN SECURED 1-12-A5 PZR HTR TRIP 1-12-B4 PZR LEVEL CONT DEV LOW 1-12-C5 PZR PHASE LOSS OR REVERSAL 1-12-D5 PZR HTR SCR CLG FAN FAILURE 1LI-459 indicating 0%

US Diagnose/Acknowledge failure of 1LT-459, Controlling Pressurizer level channel and loss of letdown.

Implement and direct the actions of 1BOA INST-2 Attachment C, PRESSURIZER LEVEL CHANNEL FAILURE

 Identify failed Pressurizer level channel 1LT-459 o

Get acknowledgements from RO and BOP.

 Informs SM of plant status for evaluation of E-Plan o

Direct WEC to write WR, CR, and get maintenance involved.

o Evaluate holding the ramp and dilution o

Briefs RO and Unit 2 assist NSO on bistable tripping.

RO/US Diagnose failure of 1LT-459.

 Announce failure and loss of letdown flow.

Perform actions of 1BOA INST-2 Attachment C, PRESSURIZER LEVEL CHANNEL FAILURE as directed by US:

 Check Pressurizer level

 If not normal, take manual control (Pressurizer Master Level controller and/ or 1CV121) to restore level.

 Select operable channel (461/460, left position) for Pressurizer level control.

 Select operable channel to level recorder (ANY but 459, normally on 460).

 Verify Pressurizer level > 17%.

EXAMINERS NOTE: Tell the SRO to direct the BOP to restore letdown

 Check Letdown established

 Re-establishes Letdown IAW BOP CV-17, ESTABLISHING AND SECURING NORMAL AND RH LETDOWN FLOW

 Restores heaters to normal.

 Restores automatic level control (Pressurizer Master Level Controller and/or 1CV121).

 Coordinates bistable tripping (expected alarm 1-12-A3).

 LB459A

Comments:

Byron 2003-301 11 Scenario 03-2 Scenario No:

03-2 Event No.

3 Event

Description:

1LT-459 Controlling Pressurizer level channel fails LOW.

Time Position Applicants Actions or Behavior BOP Performs actions as directed by US/RO:

 Assist RO as directed by US/RO with panel monitoring.

 Investigate BARs.

o Hold/control ramp o

Monitor 1A SG Level RO/BOP Re-establishing Letdown per BOP CV-17:

 Verify close 1CV8149A,B, and C.

o Assumes CC is still aligned properly to Letdown HX.

 Place 1CC-130 in manual and raise demand to 20%.

 Place 1CV-131 in manual and raise demand to 20%.

 Verify open 1CV8401A/B

 Verify close 1CV381A

 Verify open 1CV381B

 Verify open 1CV8160 and 1CV8152

 Verify open 1CV8389A/B.

 Verify open 1CV459 and 1CV460.

 Verify open 1CV8324A/B and 1CV8389A/B.

 Verify open 1CV8149A/B/C as desired.

 Ensure 1CC-130 maintains temperature between 105 and 115 degrees F (1TI-130) and place in AUTO

 Adjust in manual 1CV121 to match charging with letdown while establishing Pressurizer at program level and place in automatic.

US Refer to Tech Spec

 3.3.1 Reactor Trip System Instrumentation Condition K - trip channel within 6 hrs.

 3.3.4 Remote Shutdown System Condition A - Restore within 30 days

 3.3.3 Post Accident Monitoring Instrumentation Condition B - Restore within 30 days NOTE: Following actions for failed Pressurizer level channel and lead examiners concurrence, the next event may be initiated.

Comments:

Byron 2003-301 12 Scenario 03-2 Scenario No:

03-2 Event No.

4 Event

Description:

Failure of 1TCV-130A to control temperature / modulates closed.

Time Position Applicants Actions or Behavior CUE Annunciators:

1-9-E2 LTDWN TEMP HIGH 1-2-D7 CNMT PEN CLG FLOW HIGH LOW 1-8-C5 LTDWN HX OUTLET TEMP HIGH Indicated Letdown Heat Exchanger outlet temperature decreasing (1TI-130)

Letdown Heat Exchanger outlet temperature controller 1TK-130 demand decreasing or 0%

1TCV-129 Diverts to VCT Note: Crew may enter 1BOA PRI-6 due to the high letdown temperature US Diagnose/Acknowledge failure of 1TI-130.

o Direct use of BARs.

o Direct manual control of Letdown Heat Exchanger outlet temperature controller 1TK-130 Controller to re-establish proper letdown cooling flow.

o Direct closing letdown orifice isolation valves o 1CV8149A o 1CV8149B o 1CV8149C

 Determine automatic control problem.

o Dispatch operator to locally check valve and reports status to crew.

o Contact Chemistry for Demin Effluent sample.

 Informs SM of status.

o Order WEC to generate WR, CR, and get maintenance involved for repairs RO Announce increasing letdown temperature trend and 1CC-130A closed.

o Dispatch operator to locally check valve and reports status to US.

 Verify High Temperature divert valve diverts letdown flow and reports to US.

o Take manual control of 1CC-130 and restores cooling flow.

o Reduce flow by closing letdown orifice isolation valves o 1CV8149A o 1CV8149B o 1CV8149C

 Verify 1-9-E2 clears.

 Determine automatic control problem and reports to US.

 Restore letdown flow to VCT when directed by US.

Comments:

Byron 2003-301 13 Scenario 03-2 Scenario No:

03-2 Event No.

4 Event

Description:

Failure of 1TCV-130A to control temperature / modulates closed.

Time Position Applicants Actions or Behavior BOP Review BARs Monitor control board indications.

o Hold/control ramp.

o Dispatch operator to locally check valve and reports status to US.

o Dispatch operator to reset containment penetration cooling flow low o

Monitor 1A SG Level o

Assist RO as directed by SRO NOTE: Following actions for failed temperature instrument and lead examiners concurrence, the next event may be initiated.

Comments:

Byron 2003-301 14 Scenario 03-2 Scenario No:

03-2 Event No.

5 Event

Description:

1MS018D, 1D SG PORV Fails OPEN.

Time Position Applicants Actions or Behavior CUE Indications:

RCS Tave decreasing Reactor power increasing Reactor power/ turbine power mismatch increasing Red PORV open position indication light lit.

LVDT meter indication increasing above 0%.

BOP Diagnoses 1D SG PORV open

 Determine SG pressure is below setpoint (1115 psig)

 Report failure to US.

Perform actions directed by US:

 Place PORV control switch to close.

o Report/Acknowledge SG 1D PORV TROUBLE annunciator (1-15-D10) as expected alarm.

 Report 1D SG PORV closed.

o Dispatch operator to AEER to PORV controller box.

o Dispatch operator to locally isolate 1MS018D by closing 1MS019D.

 Report status to US.

US Diagnose/Acknowledge failure of 1D SG PORV open and direct actions:

o Determine SG pressure < PORV setpoint.

o Dispatch operator to isolate PORV by closing 1MS019D.

 Inform SM of plant status.

o Order WEC to generate WR, CR, and get maintenance involved for repairs.

RO Diagnose/Acknowledge failure of 1D SG PORV OPEN.

Monitor Reactor and Primary parameters for effects and expected response:

o Reactor Power o

Tave, Delta I and rod motion.

o Assist as directed by US.

o Investigate BARs.

US Refer to Tech Spec

 3.7.4 Steam Generator PORVs Condition A - Restore within 30 days o

3.6.3. Containment Isolation Valves (not applicable, PORV is in its isolation position.)

NOTE: Following actions for failed PORV and lead examiners concurrence, the next event may be initiated.

Comments:

Byron 2003-301 15 Scenario 03-2 Scenario No:

03-2 Event No.

6 Event

Description:

Component Cooling (CC) Surge Tank level transmitter level tree leak results in auto makeup and 1B CC pump trip with a failure of 1A CC pump to auto start. EVENT NOT USED - NOT NEEDED Time Position Applicants Actions or Behavior CUE:

Annunciators:

1-2-A5 CC SURGE TANK LEVEL HIGH/LOW 1-2-E4 CC SURGE TANK AUTO M/U ON 1-2-A4 CC PUMP TRIP 1B CC pump trip indication 1LI-676 indication at 0%

NOTE: 1BOA PRI-6, COMPONENT COOLING MALFUNCTION, may be referenced but is not written to address a CC surge tank level tree leak.

BOP/US Identify/report:

 CC Surge tank level low

 Automatic makeup with CC Surge tank demin water makeup valve 1CC183 open

 1B CC pump trip

 1A CC pump did not automatically start o

Refer to BARs CREW Determine CC Surge tank level tree leak.

o Dispatch operator to investigate

 Dispatch operator to locally isolate make-up from Demin Water.

 Directs operator to locally drain CC surge tank level to normal range as appropriate.

BOP Refer to BAR 1-2-E4 and manually control CC Surge tank level.

 Manually start 1A CC pump

 Dispatch operator to check 1A CC pump for proper operation.

US Refer to Tech Specs

 3.7.7 Component Cooling System Condition B - restore in 7 days (for 1B CC pump trip) o If the crew decides to conservatively declare the 1A CC pump inoperable until further information is available then LCO 3.0.3 would apply.

NOTE: Following local isolation of demin makeup, and lead examiners concurrence, the next event may be initiated.

Comments:

Byron 2003-301 16 Scenario 03-2 Scenario No:

2 Event No.

7 Event

Description:

1A SG Steam line break inside containment resulting in a Reactor trip, all MSIVs fail open, 4 faulted SGs.

Manual actions required to establish and control AFW flow.

Time Position Applicants Actions or Behavior CUE Annunciators:

1-1-A2 CNMT DRAIN LEAK DETECT FLOW HIGH 1-3-D4 CNMT PRESS HIGH 1-11-E1 CNMT PRESS HIGH SI/RX TRIP 1-15-A/B/C/D4 SG 1A/B/C/D LEVEL LOW 1-15-E4 P-4 FW ISOL Indications:

Containment pressure increasing RCS temperature decreasing Increased steam flow US/CREW Implement and direct the actions of 1BEP-0, REACTOR TRIP OR SAFETY INJECTION o

Get acknowledgements from RO and BOP.



Informs SM of plant status for evaluation of E-Plan o

Manually trip reactor or respond to Auto Trip o

Manually SI or respond to Auto SI RO Perform actions of 1BEP-0:

Verify reactor trip:

 Rod bottom lights Lit.

 Reactor trip and bypass breakers open.

 Neutron flux decreasing.

BOP Verify Turbine tripped

 All throttle valves closed

 All governor valves closed Verify 4KV ESF Busses energized

 Bus 141 bus alive light lit

 Bus 142 bus alive light lit RO Determine SI needed/actuated:

 SI First Out Annunciator lit (1-11-B/C/D/E1)

 SI ACTUATED lit (1-BP-4.1)

 SI Equipment actuated

 Manually Actuate SI

Comments:

Byron 2003-301 17 Scenario 03-2 Scenario No:

2 Event No.

7 Event

Description:

1A SG Steam line break inside containment resulting in a Reactor trip, all MSIVs fail open, 4 faulted SGs.

Manual actions required to establish and control AFW flow.

Time Position Applicants Actions or Behavior BOP Verify FW Isolation:

 FW pumps tripped.

 FW Isolation Monitor Lights lit.

 FW pumps discharge valves (1FW002A,B, and C) closed.

RO/US Check ECCS pumps running:

 Both CV pumps.

 Both RH pumps.

 Both SI pumps.

BOP/US Verify Containment Conditions:

 RCFC Accident Mode lights lit (Group 2)

 Phase A lights lit (Group 3)

 Containment Ventilation lights lit (Group 6)

BOP CT E-0--F Verify AFW SYSTEM:

o Report neither AFW pump auto started.

o Attempt start of Both AFW pumps.

 Manually Start 1B AFW pump.

o Report failure of 1A AFW pump to manually start (after attempt).

o Report 1B AFW pump was manually started (after attempt).

o Dispatch operator(s) to check 1A AFW pump and breaker to investigate failure to start.

o Dispatch operator(s) to check 1B AFW pump to ensure proper operation.

 1AF013E-H open (No running pump on Train A) o 1AF005E full open

 1AF005F-H throttled. (No running pump on Train A)

BOP Verify Pumps Running:

 1A CC pump.

o U0 CC pump

 Both SX pumps.

CREW Determine Steamline Isolation Required:

 Any SG pressure < 640 psig (or will become < 640 psig).

 Containment pressure approaching 8.2 psig or has exceeded 8.2 psig.

 Actuate Main Steam isolation (Both switches, and the individual MSIV switches) and verify Main Steam isolation bypasses closed.

Comments:

Byron 2003-301 18 Scenario 03-2 Scenario No:

2 Event No.

7 Event

Description:

1A SG Steam line break inside containment resulting in a Reactor trip, all MSIVs fail open, 4 faulted SGs.

Manual actions required to establish and control AFW flow.

Time Position Applicants Actions or Behavior Note: CS will eventually be required due to 4 SGs blowing down inside containment. When pressure exceeds 20 psig, then following step must be performed.

BOP Check if Containment Spray required:

 Containment pressure increased to > 20 psig

 Group 6 CS Monitor lights lit.

 Group 6 Phase B Isolation Monitor lights lit.

 Stop All RCPs.

 CS Eductor Suction Flow > 15 gpm (1FI-CS013 or 1FI-CS014).

 CS Eductor Additive Flow > 5 gpm (1FI-CS015 or 1FI-CS016).

BOP Align SX Cooling Towers

 All eight riser valves open



0SX163A thru 0SX163H

 All four Hot Water Basin Bypass valves closed



0SX162A thru 0SX162D

 All eight SX Cooling Tower Fans running in high speed Verify total AFW flow:

 > 500 gpm.

 Control feed flow to maintain narrow range SG levels 10% (31% Adverse) to 50%.

 Verify no SG level is increasing in an uncontrolled manner.

RO/BOP Verify ECCS Valve Alignment:

 Group 2 Cold Leg Injection lights lit.

o Reports Exceptions (1B CC pump, and 1A AFW pump)

 Align SVAG Valve power switches and dispatch NLO to energize breakers RO Verify ECCS Flow:

 High Head SI flow > 100 gpm o RCS pressure < 1700 psig o SI pump flow > 200 gpm

 RCS pressure > 325 psig

 RH pump flow < 1000 gpm RO Pressurizer PORV relief path available:



At least one block valve energized



PORV in automatic Associated block valve open

Comments:

Byron 2003-301 19 Scenario 03-2 Scenario No:

2 Event No.

7 Event

Description:

1A SG Steam line break inside containment resulting in a Reactor trip, all MSIVs fail open, 4 faulted SGs.

Manual actions required to establish and control AFW flow.

Time Position Applicants Actions or Behavior BOP Verify Generator Trip



OCB 3-4 open



OCB 4-5 open



PMG output breaker open BOP Verify DGs running



Both DGs running



1SX169A open



1SX169B open Examiners note: US and RO will likely continue in 1BEP-0 while BOP is performing the next 3 ventilation steps:

BOP Verify Control Room ventilation aligned for emergency operations:

 Dispatch NLO to trip VV supply fans

 Operating VC train equipment running

 Supply fan

 Return fan

 M/U fan

 Chilled water pump

 MCR chiller 0A running

 Operating VC train dampers

 M/U fan outlet damper NOT full closed 0VC24Y

 VC train M/U filter light LIT

 Operating VC train Charcoal Adsorber aligned for train A

 0VC43Y closed

 0VC21Y open

 0VC22Y open o

Control Room pressure greater than +0.125 inches water on 0PDI-VC038 BOP Verify Auxiliary Building ventilation aligned

 Two inaccessible filter plenums aligned

 Plenum A fan 0VA03CB running

 Damper 0VA023Y open

 Damper 0VA436Y closed

 Plenum C fan 0VA03CF running

 Damper 0VA072Y open

 Damper 0VA438Y closed

Comments:

Byron 2003-301 20 Scenario 03-2 Scenario No:

2 Event No.

7 Event

Description:

1A SG Steam line break inside containment resulting in a Reactor trip, all MSIVs fail open, 4 faulted SGs.

Manual actions required to establish and control AFW flow.

Time Position Applicants Actions or Behavior BOP Verify FHB ventilation aligned

 Train B fan 0VA04CB running

 0VA055Y open

 0VA062Y open

 0VA435Y closed RO Check Pressurizer sprays & PORVs closed



Normal spray valves closed 1RY455B and 1RY455C



PORVs closed 1RY455A and 1RY456 RO Maintain RCS Temperature Control:



With any RCP running, RCS Tave stable at or trending to 557 degrees F.



With No RCP running, RCS Cold Leg temperature stable at or trending to 557 degrees F.

BOP/RO If temperature is < 557 and decreasing, then perform the following:

 Stop dumping steam.

 Maintain total feed flow > 500 gpm until at least 1 SG is > 10 % (31% Adverse).

 Verify the following valves closed:



Steam Dump valves.



MS RHTR Shutoff valves (1MS009A-D).



MS RHTR S/U Purge Control Valves (1MS067A-D).



MFP turbine HP Stop valves.

Note: Containment pressure may have reached the spray initiation point, and the RCPs could be already stopped. If so, the diagnostic for a faulted SG will be performed and not all of the following steps will be necessary.

RO CHECK Status of RCPs:

 Determine if RCPS are running.

 Check if RCPS should be stopped:

 ECCS flow-high head > 100 gpm; or SI pump > 200 gpm.

 RCS pressure < 1425 psig.

 Controlled cooldown NOT in progress, nor previously initiated.

 Stop All RCPs.

CREW Determine faulted SG(s) exist:

 ALL SG pressure decreasing uncontrollably.

 Any SG completely depressurized.

Comments:

Byron 2003-301 21 Scenario 03-2 Scenario No:

2 Event No.

7 Event

Description:

1A SG Steam line break inside containment resulting in a Reactor trip, all MSIVs fail open, 4 faulted SGs.

Manual actions required to establish and control AFW flow.

Time Position Applicants Actions or Behavior CREW/US Implement and direct the actions of 1BEP-2, FAULTED STEAM GENERATOR ISOLATION:

 Announce transition to 1BEP-2 o Get acknowledgements from RO and BOP.

 Inform SM of plant status, evaluate for E-Plan.

 Request STA report to control room for Status Tree monitoring.

Examiners Note: The STA will monitor Status Trees when requested by the US/Crew. A challenge to Containment could be identified by the STA and he will make the recommendation to transition to and implement 1BFR-Z.1, Response to Containment High Pressure if containment pressure exceeds 20 psig, even if spray is already operating. Refer to page 20 for the evaluation of the crew when in 1BFR-Z.1.

BOP/RO Check Main Steam Isolation:



No Main Steam isolation valves closed



Main Steam bypass valves closed



Manually actuate Main Steamline isolation US Determine All Steam Generators are Faulted:



Check pressures in all SGs, and determine none are stable or increasing.

Implement and direct the actions of 1BCA-2.1 UNCONTROLLED DEPRESSURIZATION OF ALL SG



Announce Transition to 1BCA-2.1 o

Get acknowledgements from RO and BOP.



Inform SM of plant status, evaluate for E-Plan.

BOP Check Secondary Pressure boundary:

o Request maintenance assistance to close MSIVs.



Verify Main Steam isolation bypass valves all closed.



Check all SG PORVs Closed



Check FW Isolated to all SGs (FWI Monitor lights lit).



Check SG Blowdown Isolation and Sample valves all closed.

BOP/RO CT CA-2.1A.

Control Feed Flow to Minimize RCS Cooldown:



Determine cooldown rate in all RCS cold legs > 100 degrees F in any one hour.



Decrease feed flow to 45 gpm to each steam generator.



Report no control of feed flow to 1A Steam Generator.

o Set 1AF005E flow controller to 0%.

o Attempt to throttle 1AF013E



Dispatch operator to locally close 1AF005E.



Check Hot Leg temperatures stable or decreasing.

Comments:

Byron 2003-301 22 Scenario 03-2 Scenario No:

2 Event No.

7 Event

Description:

1A SG Steam line break inside containment resulting in a Reactor trip, all MSIVs fail open, 4 faulted SGs.

Manual actions required to establish and control AFW flow.

Time Position Applicants Actions or Behavior RO/BOP Check Status of RCPs



NO RCPs running Monitor AFW pump Suction Pressure:



1-3-E7 AF PUMP SX SUCT VLVS ARMED not lit.

RO Check Pressurizer PORVs and isolation valves:



PORV isolation valves 1RY8000A and 1RY8000B energized.



PORV 1RY455A and 1RY456 closed.



PORV isolation valves at least one open.

BOP/US Check Secondary radiation



Reset Phase A Isolation.



Request Chemistry to sample all SGs.



Check Secondary Radiation trends normal for plant conditions:



SJAE/GS Exhaust.



SG Blowdown Liquid.



Main Steamline Radiation.

CREW Determine RH pumps can be stopped:



Both RH pumps running with suction aligned to the RWST.



RCS pressure stable or increasing and > 325 psig.



Reset SI, and verify SI Actuated light not lit, and the AUTO SI BLOCKED light lit.



Stop RH pumps and place in standby.

Note: If CS is stopped in the next step, Containment pressure must be monitored for CS restart conditions (> 20 psig).

BOP/US Check if CS can be stopped:



Both CS pumps are running.



Reset CS signal.



Spray additive tank low 2 lights are not lit



Close 1CS019A and 1CS019B (per Caution prior to step 8, 1BCA-2.1).

Check Containment pressure < 15 psig.



If Containment pressure < 15 psig, stop both CS pumps.



If CS pumps stopped, Verify/Close 1CS019A and 1CS019B, and 1CS007A and 1CS007B.

Examiners Note: Scenario termination is completion of Step 8 of BCA-2.1 or Entry into BEP ES-1.3 Scenario EPlan classification is HU2

Comments:

Byron 2003-301 23 Scenario 03-2 Scenario No:

2 Event No.

7 Event

Description:

1A SG Steam line break inside containment resulting in a Reactor trip, all MSIVs fail open, 4 faulted SGs.

Manual actions required to establish and control AFW flow.

Time Position Applicants Actions or Behavior Note: The following is to be used whenever the crew implements 1BFR-Z.1, Response to High Containment Pressure.

US



Implement and direct the actions of 1BFR-Z.1:



Announces procedure transition o

Get acknowledgements from RO/BOP.



Informs SM of plant status and E-Plan evaluation.

RO/BOP Perform actions of 1BFR-Z.1 as directed:



Verify Containment isolation Phase A-Group 3 Containment isolation monitor lights lit.



Verify Containment Ventilation isolation-Group 6 Containment Vent isolation monitor lights lit.



Determines CS is required (Containment pressure has increased to > 20 psig).



Stops all RCPs if NOT previously stopped.

Comments:

Byron 2003-301 24 Scenario 03-2 Scenario No:

2 Event No.

7 Event

Description:

1A SG Steam line break inside containment resulting in a Reactor trip, all MSIVs fail open, 4 faulted SGs.

Manual actions required to establish and control AFW flow.

Time Position Applicants Actions or Behavior BOP o

Performs actions of 1BFR-Z.1 as directed:



Verifies proper CS system alignment:



CS suction valves open



1CS001A\\ 1CS009A, or 1CS001B\\ 1CS009B.



CS pump header isolation valves open



1CS007A and 1CS007B.



CS eductor spray additive valves open



1CS019A and 1CS019B.



CS eductor inlet flow control valves open



1CS010A and 1CS010B.



CS pumps running.



Group 6 Phase B lights Lit.



CS pump discharge flow > 200 gpm (1FI-CS011\\1FI-CS012)



CS eductor suction flow > 15 gpm (1FI-CS013\\ 1FI-CS-014).



CS eductor additive flow > 5 gpm (1FI-CS015\\ 1FI-CS016).



Reset CS signal.



Check Spray additive tank LO-2 lights



then closes 1CS019A and 1CS019B even if NOT lit per Caution prior to Step 3, 1BFR-Z.1 (Secondary Break only).

Align SX Cooling Towers

 All eight riser valves open



0SX163A thru 0SX163H

 All four Hot Water Basin Bypass valves closed



0SX162A thru 0SX162D

 All eight SX Cooling Tower Fans running in high speed



Verify RCFCs running in Accident Mode



Group 2 RCFC Accident Mode status lights lit.



Determines Main Steamline isolation necessary and manually actuates Main Steamline isolation and verifies Main Steam bypass valves closed. Reports all Main Steam isolation valves still open.

Comments:

Byron 2003-301 25 Scenario 03-2 Scenario No:

2 Event No.

7 Event

Description:

1A SG Steam line break inside containment resulting in a Reactor trip, all MSIVs fail open, 4 faulted SGs.

Manual actions required to establish and control AFW flow.

Time Position Applicants Actions or Behavior BOP CT:

CA-2.1A.

o Determine all SGs are faulted and controls AFW Flow:



Any SG pressure decreasing uncontrollably or completely depressurized.



Control AFW flow to 1B, 1C, and 1D SG at 45 gpm per SG by throttling 1AF005F, G, and H; or 1AF013F, G, and H.



Attempt Control of AFW to 1A SG via 1AF005E, and 1AF013E and reports no control available.

o Set potentiometer for 1AF005E to 0%.



Dispatches operator to locally throttle 1AF005E.



Checks FW isolated to all SGs



All FW Isolation Monitor lights lit.

US



Returns to step and procedure in effect:



Announces procedure transition and gets acknowledgements for RO and BOP.



Informs SM of Status.

Byron 2003-301 1

Scenario 03-2 Simulation Facility Byron Scenario No. 2a Operating Test No. 2003-301 Examiners:

Applicant:

SRO RO BOP Initial Conditions:

IC-18, 75% power, steady state, BOL.

Turnover: Ramp to full power requested by Electric Operations. 1A Motor driven FW is out of service due to breaker cubicle work.

Event No.

Malf. No.

Event Type*

Event Description Preload RF RP64 OUT RF RP71 OUT RF RP95 OUT RF RP97 OUT FW43 MS01A 75 MS01B 80 MS01C 60 MS01D 90 FW45E, 100 Override ZDI1AF013E AUTO C BOP C BOP C RO BOP SRO C BOP C BOP SRO 1B Auxiliary Feedwater pump fails to auto start, can be manually started.

1A Auxiliary Feedwater pump fails to auto or manually start.

All Main Steam isolation valves fail partially open, no closure available.

1AF005E potentiometer fails to 100% demand.

1AF013E stuck open.

1 R RO SRO N BOP Raise Reactor Power using rods and dilution Ramp up turbine power from 75% to full power.

2 RX29A 65 PN0610 on C BOP SRO Steam Generator 1A Feedwater regulating valve Controller card failure resulting in manual control of Feedwater regulating valve 3

3A RX13A, 0 I RO SRO N BOP 1LT-459, Controlling Pressurizer level channel fails low.

Restore Letdown 4

CV09, 50 C RO SRO 1TCV-130A modulates closed 5

MS04D, 100 C BOP SRO 1MS018D, 1D SG PORV fails open.

6 CC03B CC01C CC02A I BOP SRO Component Cooling (CC) Surge Tank level transmitter level tree leak results in auto makeup and 1B CC pump trip with failure of 1A CC pump auto start on low header pressure.

7 MS07A, 2.0 (Pre-loaded)

M BOP RO SRO 1A SG Steam line break (2 MLB/HR) inside containment. 4 faulted steam generators.

All MSIVs fail to Close. Stuck open 8

1A and 1B AFW pumps fail to Start C BOP SRO Pre-loaded. 1A Auxiliary Feedwater pump fails to start. 1B Auxiliary Feedwater pump can only be manually started.

Byron 2003-301 2

Scenario 03-2

  • (N)ormal, (R)eactivity (I)nstrument, (C)omponent, (M)ajor Transient

Byron 2003-301 3

Scenario 03-2 SCENARIO OVERVIEW The scenario begins with the plant at 75% power and a ramp to full power @ 5 MW/Min is requested via the turnover. The turnover includes information that the 1A Motor driven FW pump is out of service for breaker cubicle work.

After the requested reactivity change, 1A Steam Generator Feedwater regulating valve 1FW510 controller will experience a card failure requiring the operator to manually control. The operators will need to monitor 1A feedwater flow during the requested load change and the rest of the scenario. The BOP will diagnose the failure and manually control the 1A S/G feed regulating valve.

Following the failure of 1A SG regulating valve controller failure, a failure of the controlling channel of Pressurizer level will occur causing letdown to isolate. The crew will respond by diagnosing the failure of the level channel and entering and performing the actions of 1BOA INST-2 Attachment C, OPERATION WITH A FAILED INSTRUMENT - PRESSURIZER LEVEL CHANNEL FAILURE. An alternate controlling level channel will be selected, letdown will be restored, and the crew will take actions to restore pressurizer level to the program value. Bistables will be tripped for the failed channel, and Technical Specifications will be investigated. LCO 3.3.1 condition K will apply. Maintenance will investigate as requested.

Following the restoration of letdown and bistable tripping, the transmitter for 1TI-130 Letdown heat exchanger outlet temperature controller fails low causing actual letdown temperature to increase resulting in a high temperature diversion around the mixed bed demineralizers. Manual control of the temperature controller is available and will be necessary to restore letdown temperature to normal. Annunciator response procedures will be referenced to respond to the failure.

When manual control of the letdown temperature control valve is selected, a 1D S/G PORV controller failure will cause the 1D S/G PORV to open. RCS Tave will decrease possibly causing control rod motion in the outward direction. The crew will investigate and diagnose the inadvertent PORV failure. Emergency closure of the PORV will be available from the control room and the PORV may be locally isolated if directed by the crew. The SRO will determine Technical Specification 3.7.4 applies.

A Component Cooling (CC) Water surge tank level tree leak will result in low level indication causing automatic makeup from demineralized water and automatic trip of the 1B CC pump. The 1A CC pump will fail to automatically start requiring the operators to manually start the pump. The crew should identify the failure and dispatch an operator to locally isolate demineralized water makeup to the surge tank. Local surge tank level indication is available and the crew should instruct local operations to drain the surge tank to normal level and address operability concerns for 1B CC pump. The SRO will determine Technical Specification 3.7.7 applies.

A 1A S/G Steamline break inside of containment will occur requiring a safety injection. 1BEP-0, REACTOR TRIP OR SAFETY INJECTION will be entered. Containment pressure will exceed the Containment Spray actuation setpoint. Manual action will be required to start the 1B Auxiliary Feedwater pump. The 1A Auxiliary Feedwater pump will fail to start. A diagnosis of a Faulted S/G will cause transition to 1BEP-2, FAULTED SG ISOLATION. Further diagnosis will determine 4 faulted S/Gs exist due to failure of all Main Steam isolation valves to close and a transition to 1BCA-2.1, UNCONTROLLED DEPRESSURIZATION OF ALL S/Gs will be made. Depending on the timing, a transition to 1BFR Z.1, RESPONSE TO CONTAINMENT HIGH PRESSURE, may occur after exiting the Reactor Trip/Safety Injection procedure. Manual operator action will be required to throttle AFW flow to a minimum to the SGs. Local operator action will be required to throttle B Train AFW flow to the faulted 1A S/G due to a failure of the potentiometer and a stuck open isolation valve. Containment Spray may be terminated (depending on the amount of secondary water inventory remaining in the SGs and the RCS temperature) before reaching the LO-2 RWST setpoint for automatic swap over to the containment sump and an unnecessary injection of sump water into the RCS. NaOH addition to the CS water could be stopped due to the break being on a secondary system. If the LO-2 RWST level is reached, then the crew will transition to 1BEP ES-1.3, TRANSFER TO COLD LEG RECIRCULATION and then back to the procedure and step in effect. The crew will proceed to terminate the safety injection in 1BCA 2.1. Scenario termination is completion of step 8 of 1BCA-2.1 or Entry into 1BEP ES-1.3 Scenario EPlan classification is HU2 Critical Tasks E-0F Establish the minimum required AFW flow rate to the SGs before transition out of E-0, unless the transition is to FR-H.1, in which case the task must be initiated before RCPs are manually tripped per FR-H.1.

ECA-2.1---A Control the AFW flow rate to not less than 45 gpm per SG in order to minimize the RCS Cooldown rate before a severe (orange path) challenge develops to the integrity CSF.

Byron 2003-301 4

Scenario 03-2 SIMULATOR OPERATOR NOTES:

Simulator Setup:

Init IC 18, BOL, Xenon equilibrium, steady state.

Ensure 1B CC pump is running and 1A CC pump in standby With the simulator running, in an expert window type cae d:\\byron\\2003_demos\\nrc2.cae and verify the following:

Place 1A MFP control switch to Pull Out and hang tag.

RF RP64 OUT 1B AFW pump fails to auto start, can be manually started.

RF RP71 OUT RF RP95 OUT RF RP97 OUT IMF FW43 1A Auxiliary Feedwater pump fails to auto or manually start.

IMF MS01A 75, MS01B 80, MS01C 60, MS01D 90 open, no closure available.

IMF FW45E 100 1AF005E potentiometer fails at 100% demand.

IOR ZDI1AF013E AUTO 1AF013E stuck open.

Ensure Trigger 3 is setup as event zao1li676.lt. 0.15 command IMF CC01C trgset 4 "yp:mrx29a.eq. 1" command "imf pn0610 on" Event 1 Power ramp from 75% up to 100%.

As SM acknowledge ramp initiation.

As Radiation Protection/Chemistry acknowledge sample requirements for power change > 15% in one hour.

Event 2 Steam Generator 1A Feedwater regulating valve Controller card failure resulting in manual control of Feedwater regulating valve.

Acknowledge all info passed to the SM, WEC, and maintenance.

Trigger 4 will activate annunciator 1-4-A3. If dispatched to 1PA05J to investigate the Process I&C Cabinet Power Supply failure alarm report that no obvious problems are present.

Event 3 Controlling Pressurizer level channel fails low (1LT-459).

SDG:

RX6 Malf:

RX13A, 0 severity, no ramp.

Initiate at lead examiners cue.

Role play as U-2 assist and/or extra NSO to accomplish bistable tripping. Acknowledge all info passed to the SM, WEC, and maintenance.

SDG:

RX6 Cabinet door #1 Open RF RP20 OPEN Hi Level Trip LB459A C1-751 BS-1 RF RX029 TRIP Cabinet door #2 Close RF RP20 CLOSE Event 4 On line letdown heat exchanger (1A) Temperature transmitter for 1TI-130 fails low SDG:

CV2 and CC6 Initiate after Letdown temperature controller is placed back in automatic after event 3.

Malf:

CV09, 50 Intent is to cause operator to have to take manual control of the TCV-130 controller and restore letdown temperature without having to swap letdown heat exchangers. Manual control via the M/A station is available on this malfunction. Acknowledge all info passed to the SM, WEC, and maintenance. If dispatched as local operator, use first check and report no obvious problems at the valve. Valve appears to operate smoothly from local observation. Use Remote Function CC50 to reset Penetration Cooling alarm if dispatched.

Byron 2003-301 5

Scenario 03-2 Event 5 1D SG PORV 1MS018D, fails open.

SDG:

MS4 Initiate after letdown temperature is stabilized or at lead examiners cue.

Malf:

MS04D, 100, no ramp If dispatched to the controller box in the AEER, report no obvious problems. If dispatched to locally close 1MS019D, wait 5 minutes, use first check, and then use RF: MS54 CLOSE to close the isolation valve. Report 1MS019D closed when completed. Acknowledge all info passed to the SM, WEC, and maintenance. If asked, on-line risk is Yellow.

Event 6 Component Cooling (CC) Surge Tank level transmitter level tree leak results in auto makeup and 1B CC pump trip with failure of the 1A CC pump to auto start.

SDG: CC2 Malf: CC03B, 0 and CC01C and (CC02A at current value, preload)

Initiate event after actions for the Porv failure are complete or at lead examiners cue.

If dispatched as Aux NLO, report a leak on the level tree and local Surge tank levels indicate high and take actions as directed to isolate Demin water (WM) makeup to CC tank. The leak can be isolated.

If dispatched as Aux NLO, report that 1A CC pump is running normally.

Use Remote Function CC52 to close 1CC185, the manual isolation for demin water makeup to the CC surge tank 1CC183.

Acknowledge all info passed to the SM, WEC, and maintenance.

If directed,use first check, and use Remote Function CC15 to drain the surge tank If directed to isolate the leak report that you have closed 1CC9457A and 1CC9457B, level transmitter 676 isolation valves.

If directed to swap U0 CC pump to Bus 142 use remote functions CC42 RO and CC07 RI Event 7 Steam line break inside containment on 1A steamline.

Initiate events 7 and 8 after tech specs are investigated for the 1D SG PORV, or at the lead examiners cue.

Action:

SDG:

MS1 Malf:

MS07A, 2.0 Mlb/hr Acknowledge all info passed to SM, WEC, and others regarding reactor trip and SI and procedure transitions.

Acknowledge direction to trip Control Room Vent fans as NLO and monitoring of DG operations Wait 2 minutes and report Control Room Vent fans have been tripped Acknowledge direction to energize SVAG valves per BEP 0 step 16b After CAEPs have finished running, report the SVAG valves have been energized USE CAEP bep0step16b2a to energize valves.

Role play as STA when asked and monitor the Status Trees. Pay particular attention to the Containment Status Tree as the intent of the scenario is reach the Hi-3 setpoint. Actions in EP-0 will ensure Containment Spray is going, however if monitoring the Status Trees identifies an Orange path, report it to the US as usage rules apply.

If dispatched as local operators to check/investigate equipment, report as follows for the requested actions:

All running equipment is operating properly.

1A Auxiliary Feedwater Pump Breaker has an over current flag on phase C. Bus 141, cub 8.

Need the floor plugs removed to get to the 1AF013E.

SDG:

FW13 Use RF: FW161 to position the hand wheel for 1AF005E as requested. (8.5 will ~ 45 gpm)

Maintenance will attempt to locally close any/all MSIVs (but will be unsuccessful).

Byron 2003-301 6

Scenario 03-2

Comments:

Byron 2003-301 7

Scenario 03-2 Scenario No:

03-2 Event No.

1 Event

Description:

Raise turbine load and reactor power. EVENT NOT USED Time Position Applicants Actions or Behavior CUE Turnover information includes request from Electric Operations for an increase in Unit 1 MW to full load (1260 MWe) to begin ASAP at 5 MWe/minute.

Note: A portion of the power increase preparations may have been performed in the briefing room US Implement actions of 1BGP 100-3

 Initiate load swing instruction sheet (1BGP 100-4T2 Boration Dilution Boundary Calculation).

o Contact Chemistry and Health Physics for load change > 15% in one hr.

 Inform SM of plant Status, and Electric Operations of ramp start.

CREW Review Applicable Precautions, Limitations and Actions.

RO Verify rod position and boron concentration.

Perform reactivity manipulation calculation to determine amount of RCS dilution and expected rod outward movement to maintain Delta I within the limits of BCB-1 Fig. 19.

Determine required dilution volume by:

o Effects of previously performed dilutions.

o Byron Boration Dilution Tables.

Initiate Dilution in accordance with BOP CV5:

IF BATCH addition desired:

 Determine the desired change in RCS Tave

 Determine required gallons of primary water to change Tave IF Calculated addition desired:

 Determine required gallons of primary water to decrease RCS boron as desired NOTE: The remaining steps will be performed for either method of dilution

 Determine required primary flow rate

 Place MAKE-UP MODE CONT SWITCH to stop position

 Set MODE SELECT to dil or alt dil position

 Set 1FK-111 PW/Total Flow Control to desired flow rate (may leave at current value if Batch method used)

 Set 1FY-0111 PW/Total Flow Preset Counter to desired volume.

 Place MAKE-UP MODE CONT Switch to start.

 Verify proper operation of valves (1CV111A opens, 1CV111B opens, PW flow indicated on recorder).

Comments:

Byron 2003-301 8

Scenario 03-2 Scenario No:

03-2 Event No.

1 Event

Description:

Raise turbine load and reactor power. EVENT NOT USED Time Position Applicants Actions or Behavior BOP Initiate turbine load increase:

 Verify the DEHC IMP IN, SPEED IN, and MW IN half of the pushbuttons are illuminated.

 Depress the LOAD RATE MW/MIN pushbutton.

 Enter the desired load rate (5 MW).

 Depress the ENTER pushbutton.

 Depress the REF pushbutton.

 Enter the desired MW on the REFERENCE DEMAND Window using the numbered pushbuttons (1120).

 Depress the ENTER pushbutton.

 Depress the GO pushbutton when directed by the US/RO.

 Verify load begins to increase.

o Monitor 1A SG Level RO Monitor power increase:

 Monitor Reactor power, Tave, and Delta I.

 Verify control rods automatically move to maintain Tave within + 1.0 degree F of Tref.

If Diluting:

 Monitor VCT level.

 Monitor PW/Total counter.

 Verify dilution auto stops at preset value.

 Return Reactor Makeup system to blended flow at current boron concentration.

Note: Following clearly observable plant response from the reactivity changes and lead examiners concurrence, the next event can be initiated.

Comments:

Byron 2003-301 9

Scenario 03-2 Scenario No:

03-2 Event No.

2 Event

Description:

Steam Generator 1A Feedwater regulating valve automatic control card failure Time Position Applicants Actions or Behavior CUE Annunciators:

1-4-A3 PROCESS I&C CAB PWR SUP FAILURE 1-15-A9 STEAM GENERATOR 1A LEVEL DEVIATION HIGH LOW Increased Feed Flow to 1A SG Increasing 1A SG Level BOP Diagnose/Recognize failure of 1A Feedwater regulating valve Auto Controller.

 Announce placing 1A Feedwater regulating valve Controller in manual.

 Manually control 1FW510 to stabilize/restore level.

 Dispatch operator to 1PA05J to check for failure lights per BAR 1-4-A3 US Diagnose/Acknowledge failure of 1A Feedwater regulating valve Auto Controller.

 Orders WEC to generate WR, CR, and get maintenance involved for repairs.

RO Monitors Reactor and Primary parameters for possible effects:

 Reactor power and Delta I.

 Tave and control rod motion.

 Reports status to US.

Assists BOP as directed by US:

o Reviews BARs.

Note: Following actions from the failed controller and lead examiners concurrence, the next event may be initiated.

Comments:

Byron 2003-301 10 Scenario 03-2 Scenario No:

03-2 Event No.

3 Event

Description:

1LT-459 Controlling Pressurizer level channel fails LOW.

Time Position Applicants Actions or Behavior CUE Annunciators:

1-12-A4 PZR LVL LOW HTRS OFF LTDWN SECURED 1-12-A5 PZR HTR TRIP 1-12-B4 PZR LEVEL CONT DEV LOW 1-12-C5 PZR PHASE LOSS OR REVERSAL 1-12-D5 PZR HTR SCR CLG FAN FAILURE 1LI-459 indicating 0%

US Diagnose/Acknowledge failure of 1LT-459, Controlling Pressurizer level channel and loss of letdown.

Implement and direct the actions of 1BOA INST-2 Attachment C, PRESSURIZER LEVEL CHANNEL FAILURE

 Identify failed Pressurizer level channel 1LT-459 o

Get acknowledgements from RO and BOP.

 Informs SM of plant status for evaluation of E-Plan o

Direct WEC to write WR, CR, and get maintenance involved.

o Evaluate holding the ramp and dilution o

Briefs RO and Unit 2 assist NSO on bistable tripping.

RO/US Diagnose failure of 1LT-459.

 Announce failure and loss of letdown flow.

Perform actions of 1BOA INST-2 Attachment C, PRESSURIZER LEVEL CHANNEL FAILURE as directed by US:

 Check Pressurizer level

 If not normal, take manual control (Pressurizer Master Level controller and/ or 1CV121) to restore level.

 Select operable channel (461/460, left position) for Pressurizer level control.

 Select operable channel to level recorder (ANY but 459, normally on 460).

 Verify Pressurizer level > 17%.

EXAMINERS NOTE: Tell the SRO to direct the BOP to restore letdown

 Check Letdown established

 Re-establishes Letdown IAW BOP CV-17, ESTABLISHING AND SECURING NORMAL AND RH LETDOWN FLOW

 Restores heaters to normal.

 Restores automatic level control (Pressurizer Master Level Controller and/or 1CV121).

 Coordinates bistable tripping (expected alarm 1-12-A3).

 LB459A

Comments:

Byron 2003-301 11 Scenario 03-2 Scenario No:

03-2 Event No.

3 Event

Description:

1LT-459 Controlling Pressurizer level channel fails LOW.

Time Position Applicants Actions or Behavior BOP Performs actions as directed by US/RO:

 Assist RO as directed by US/RO with panel monitoring.

 Investigate BARs.

o Hold/control ramp o

Monitor 1A SG Level RO/BOP Re-establishing Letdown per BOP CV-17:

 Verify close 1CV8149A,B, and C.

o Assumes CC is still aligned properly to Letdown HX.

 Place 1CC-130 in manual and raise demand to 20%.

 Place 1CV-131 in manual and raise demand to 20%.

 Verify open 1CV8401A/B

 Verify close 1CV381A

 Verify open 1CV381B

 Verify open 1CV8160 and 1CV8152

 Verify open 1CV8389A/B.

 Verify open 1CV459 and 1CV460.

 Verify open 1CV8324A/B and 1CV8389A/B.

 Verify open 1CV8149A/B/C as desired.

 Ensure 1CC-130 maintains temperature between 105 and 115 degrees F (1TI-130) and place in AUTO

 Adjust in manual 1CV121 to match charging with letdown while establishing Pressurizer at program level and place in automatic.

US Refer to Tech Spec

 3.3.1 Reactor Trip System Instrumentation Condition K - trip channel within 6 hrs.

 3.3.4 Remote Shutdown System Condition A - Restore within 30 days

 3.3.3 Post Accident Monitoring Instrumentation Condition B - Restore within 30 days NOTE: Following actions for failed Pressurizer level channel and lead examiners concurrence, the next event may be initiated.

Comments:

Byron 2003-301 12 Scenario 03-2 Scenario No:

03-2 Event No.

4 Event

Description:

Failure of 1TCV-130A to control temperature / modulates closed. EVENT NOT USED Time Position Applicants Actions or Behavior CUE Annunciators:

1-9-E2 LTDWN TEMP HIGH 1-2-D7 CNMT PEN CLG FLOW HIGH LOW 1-8-C5 LTDWN HX OUTLET TEMP HIGH Indicated Letdown Heat Exchanger outlet temperature decreasing (1TI-130)

Letdown Heat Exchanger outlet temperature controller 1TK-130 demand decreasing or 0%

1TCV-129 Diverts to VCT Note: Crew may enter 1BOA PRI-6 due to the high letdown temperature US Diagnose/Acknowledge failure of 1TI-130.

o Direct use of BARs.

o Direct manual control of Letdown Heat Exchanger outlet temperature controller 1TK-130 Controller to re-establish proper letdown cooling flow.

o Direct closing letdown orifice isolation valves o 1CV8149A o 1CV8149B o 1CV8149C

 Determine automatic control problem.

o Dispatch operator to locally check valve and reports status to crew.

o Contact Chemistry for Demin Effluent sample.

 Informs SM of status.

o Order WEC to generate WR, CR, and get maintenance involved for repairs RO Announce increasing letdown temperature trend and 1CC-130A closed.

o Dispatch operator to locally check valve and reports status to US.

 Verify High Temperature divert valve diverts letdown flow and reports to US.

o Take manual control of 1CC-130 and restores cooling flow.

o Reduce flow by closing letdown orifice isolation valves o 1CV8149A o 1CV8149B o 1CV8149C

 Verify 1-9-E2 clears.

 Determine automatic control problem and reports to US.

 Restore letdown flow to VCT when directed by US.

Comments:

Byron 2003-301 13 Scenario 03-2 Scenario No:

03-2 Event No.

4 Event

Description:

Failure of 1TCV-130A to control temperature / modulates closed. EVENT NOT USED Time Position Applicants Actions or Behavior BOP Review BARs Monitor control board indications.

o Hold/control ramp.

o Dispatch operator to locally check valve and reports status to US.

o Dispatch operator to reset containment penetration cooling flow low o

Monitor 1A SG Level o

Assist RO as directed by SRO NOTE: Following actions for failed temperature instrument and lead examiners concurrence, the next event may be initiated.

Comments:

Byron 2003-301 14 Scenario 03-2 Scenario No:

03-2 Event No.

5 Event

Description:

1MS018D, 1D SG PORV Fails OPEN.

Time Position Applicants Actions or Behavior CUE Indications:

RCS Tave decreasing Reactor power increasing Reactor power/ turbine power mismatch increasing Red PORV open position indication light lit.

LVDT meter indication increasing above 0%.

BOP Diagnoses 1D SG PORV open

 Determine SG pressure is below setpoint (1115 psig)

 Report failure to US.

Perform actions directed by US:

 Place PORV control switch to close.

o Report/Acknowledge SG 1D PORV TROUBLE annunciator (1-15-D10) as expected alarm.

 Report 1D SG PORV closed.

o Dispatch operator to AEER to PORV controller box.

o Dispatch operator to locally isolate 1MS018D by closing 1MS019D.

 Report status to US.

US Diagnose/Acknowledge failure of 1D SG PORV open and direct actions:

o Determine SG pressure < PORV setpoint.

o Dispatch operator to isolate PORV by closing 1MS019D.

 Inform SM of plant status.

o Order WEC to generate WR, CR, and get maintenance involved for repairs.

RO Diagnose/Acknowledge failure of 1D SG PORV OPEN.

Monitor Reactor and Primary parameters for effects and expected response:

o Reactor Power o

Tave, Delta I and rod motion.

o Assist as directed by US.

o Investigate BARs.

US Refer to Tech Spec

 3.7.4 Steam Generator PORVs Condition A - Restore within 30 days o

3.6.3. Containment Isolation Valves (not applicable, PORV is in its isolation position.)

NOTE: Following actions for failed PORV and lead examiners concurrence, the next event may be initiated.

Comments:

Byron 2003-301 15 Scenario 03-2 Scenario No:

03-2 Event No.

6 Event

Description:

Component Cooling (CC) Surge Tank level transmitter level tree leak results in auto makeup and 1B CC pump trip with a failure of 1A CC pump to auto start. EVENT NOT USED Time Position Applicants Actions or Behavior CUE:

Annunciators:

1-2-A5 CC SURGE TANK LEVEL HIGH/LOW 1-2-E4 CC SURGE TANK AUTO M/U ON 1-2-A4 CC PUMP TRIP 1B CC pump trip indication 1LI-676 indication at 0%

NOTE: 1BOA PRI-6, COMPONENT COOLING MALFUNCTION, may be referenced but is not written to address a CC surge tank level tree leak.

BOP/US Identify/report:

 CC Surge tank level low

 Automatic makeup with CC Surge tank demin water makeup valve 1CC183 open

 1B CC pump trip

 1A CC pump did not automatically start o

Refer to BARs CREW Determine CC Surge tank level tree leak.

o Dispatch operator to investigate

 Dispatch operator to locally isolate make-up from Demin Water.

 Directs operator to locally drain CC surge tank level to normal range as appropriate.

BOP Refer to BAR 1-2-E4 and manually control CC Surge tank level.

 Manually start 1A CC pump

 Dispatch operator to check 1A CC pump for proper operation.

US Refer to Tech Specs

 3.7.7 Component Cooling System Condition B - restore in 7 days (for 1B CC pump trip) o If the crew decides to conservatively declare the 1A CC pump inoperable until further information is available then LCO 3.0.3 would apply.

NOTE: Following local isolation of demin makeup, and lead examiners concurrence, the next event may be initiated.

Comments:

Byron 2003-301 16 Scenario 03-2 Scenario No:

2 Event No.

7 Event

Description:

1A SG Steam line break inside containment resulting in a Reactor trip, all MSIVs fail open, 4 faulted SGs.

Manual actions required to establish and control AFW flow.

Time Position Applicants Actions or Behavior CUE Annunciators:

1-1-A2 CNMT DRAIN LEAK DETECT FLOW HIGH 1-3-D4 CNMT PRESS HIGH 1-11-E1 CNMT PRESS HIGH SI/RX TRIP 1-15-A/B/C/D4 SG 1A/B/C/D LEVEL LOW 1-15-E4 P-4 FW ISOL Indications:

Containment pressure increasing RCS temperature decreasing Increased steam flow US/CREW Implement and direct the actions of 1BEP-0, REACTOR TRIP OR SAFETY INJECTION o

Get acknowledgements from RO and BOP.



Informs SM of plant status for evaluation of E-Plan o

Manually trip reactor or respond to Auto Trip o

Manually SI or respond to Auto SI RO Perform actions of 1BEP-0:

Verify reactor trip:

 Rod bottom lights Lit.

 Reactor trip and bypass breakers open.

 Neutron flux decreasing.

BOP Verify Turbine tripped

 All throttle valves closed

 All governor valves closed Verify 4KV ESF Busses energized

 Bus 141 bus alive light lit

 Bus 142 bus alive light lit RO Determine SI needed/actuated:

 SI First Out Annunciator lit (1-11-B/C/D/E1)

 SI ACTUATED lit (1-BP-4.1)

 SI Equipment actuated

 Manually Actuate SI

Comments:

Byron 2003-301 17 Scenario 03-2 Scenario No:

2 Event No.

7 Event

Description:

1A SG Steam line break inside containment resulting in a Reactor trip, all MSIVs fail open, 4 faulted SGs.

Manual actions required to establish and control AFW flow.

Time Position Applicants Actions or Behavior BOP Verify FW Isolation:

 FW pumps tripped.

 FW Isolation Monitor Lights lit.

 FW pumps discharge valves (1FW002A,B, and C) closed.

RO/US Check ECCS pumps running:

 Both CV pumps.

 Both RH pumps.

 Both SI pumps.

BOP/US Verify Containment Conditions:

 RCFC Accident Mode lights lit (Group 2)

 Phase A lights lit (Group 3)

 Containment Ventilation lights lit (Group 6)

BOP CT E-0--F Verify AFW SYSTEM:

o Report neither AFW pump auto started.

o Attempt start of Both AFW pumps.

 Manually Start 1B AFW pump.

o Report failure of 1A AFW pump to manually start (after attempt).

o Report 1B AFW pump was manually started (after attempt).

o Dispatch operator(s) to check 1A AFW pump and breaker to investigate failure to start.

o Dispatch operator(s) to check 1B AFW pump to ensure proper operation.

 1AF013E-H open (No running pump on Train A) o 1AF005E full open

 1AF005F-H throttled. (No running pump on Train A)

BOP Verify Pumps Running:

 1A CC pump.

o U0 CC pump

 Both SX pumps.

CREW Determine Steamline Isolation Required:

 Any SG pressure < 640 psig (or will become < 640 psig).

 Containment pressure approaching 8.2 psig or has exceeded 8.2 psig.

 Actuate Main Steam isolation (Both switches, and the individual MSIV switches) and verify Main Steam isolation bypasses closed.

Comments:

Byron 2003-301 18 Scenario 03-2 Scenario No:

2 Event No.

7 Event

Description:

1A SG Steam line break inside containment resulting in a Reactor trip, all MSIVs fail open, 4 faulted SGs.

Manual actions required to establish and control AFW flow.

Time Position Applicants Actions or Behavior Note: CS will eventually be required due to 4 SGs blowing down inside containment. When pressure exceeds 20 psig, then following step must be performed.

BOP Check if Containment Spray required:

 Containment pressure increased to > 20 psig

 Group 6 CS Monitor lights lit.

 Group 6 Phase B Isolation Monitor lights lit.

 Stop All RCPs.

 CS Eductor Suction Flow > 15 gpm (1FI-CS013 or 1FI-CS014).

 CS Eductor Additive Flow > 5 gpm (1FI-CS015 or 1FI-CS016).

BOP Align SX Cooling Towers

 All eight riser valves open



0SX163A thru 0SX163H

 All four Hot Water Basin Bypass valves closed



0SX162A thru 0SX162D

 All eight SX Cooling Tower Fans running in high speed Verify total AFW flow:

 > 500 gpm.

 Control feed flow to maintain narrow range SG levels 10% (31% Adverse) to 50%.

 Verify no SG level is increasing in an uncontrolled manner.

RO/BOP Verify ECCS Valve Alignment:

 Group 2 Cold Leg Injection lights lit.

o Reports Exceptions (1B CC pump, and 1A AFW pump)

 Align SVAG Valve power switches and dispatch NLO to energize breakers RO Verify ECCS Flow:

 High Head SI flow > 100 gpm o RCS pressure < 1700 psig o SI pump flow > 200 gpm

 RCS pressure > 325 psig

 RH pump flow < 1000 gpm RO Pressurizer PORV relief path available:



At least one block valve energized



PORV in automatic Associated block valve open

Comments:

Byron 2003-301 19 Scenario 03-2 Scenario No:

2 Event No.

7 Event

Description:

1A SG Steam line break inside containment resulting in a Reactor trip, all MSIVs fail open, 4 faulted SGs.

Manual actions required to establish and control AFW flow.

Time Position Applicants Actions or Behavior BOP Verify Generator Trip



OCB 3-4 open



OCB 4-5 open



PMG output breaker open BOP Verify DGs running



Both DGs running



1SX169A open



1SX169B open Examiners note: US and RO will likely continue in 1BEP-0 while BOP is performing the next 3 ventilation steps:

BOP Verify Control Room ventilation aligned for emergency operations:

 Dispatch NLO to trip VV supply fans

 Operating VC train equipment running

 Supply fan

 Return fan

 M/U fan

 Chilled water pump

 MCR chiller 0A running

 Operating VC train dampers

 M/U fan outlet damper NOT full closed 0VC24Y

 VC train M/U filter light LIT

 Operating VC train Charcoal Adsorber aligned for train A

 0VC43Y closed

 0VC21Y open

 0VC22Y open o

Control Room pressure greater than +0.125 inches water on 0PDI-VC038 BOP Verify Auxiliary Building ventilation aligned

 Two inaccessible filter plenums aligned

 Plenum A fan 0VA03CB running

 Damper 0VA023Y open

 Damper 0VA436Y closed

 Plenum C fan 0VA03CF running

 Damper 0VA072Y open

 Damper 0VA438Y closed

Comments:

Byron 2003-301 20 Scenario 03-2 Scenario No:

2 Event No.

7 Event

Description:

1A SG Steam line break inside containment resulting in a Reactor trip, all MSIVs fail open, 4 faulted SGs.

Manual actions required to establish and control AFW flow.

Time Position Applicants Actions or Behavior BOP Verify FHB ventilation aligned

 Train B fan 0VA04CB running

 0VA055Y open

 0VA062Y open

 0VA435Y closed RO Check Pressurizer sprays & PORVs closed



Normal spray valves closed 1RY455B and 1RY455C



PORVs closed 1RY455A and 1RY456 RO Maintain RCS Temperature Control:



With any RCP running, RCS Tave stable at or trending to 557 degrees F.



With No RCP running, RCS Cold Leg temperature stable at or trending to 557 degrees F.

BOP/RO If temperature is < 557 and decreasing, then perform the following:

 Stop dumping steam.

 Maintain total feed flow > 500 gpm until at least 1 SG is > 10 % (31% Adverse).

 Verify the following valves closed:



Steam Dump valves.



MS RHTR Shutoff valves (1MS009A-D).



MS RHTR S/U Purge Control Valves (1MS067A-D).



MFP turbine HP Stop valves.

Note: Containment pressure may have reached the spray initiation point, and the RCPs could be already stopped. If so, the diagnostic for a faulted SG will be performed and not all of the following steps will be necessary.

RO CHECK Status of RCPs:

 Determine if RCPS are running.

 Check if RCPS should be stopped:

 ECCS flow-high head > 100 gpm; or SI pump > 200 gpm.

 RCS pressure < 1425 psig.

 Controlled cooldown NOT in progress, nor previously initiated.

 Stop All RCPs.

CREW Determine faulted SG(s) exist:

 ALL SG pressure decreasing uncontrollably.

 Any SG completely depressurized.

Comments:

Byron 2003-301 21 Scenario 03-2 Scenario No:

2 Event No.

7 Event

Description:

1A SG Steam line break inside containment resulting in a Reactor trip, all MSIVs fail open, 4 faulted SGs.

Manual actions required to establish and control AFW flow.

Time Position Applicants Actions or Behavior CREW/US Implement and direct the actions of 1BEP-2, FAULTED STEAM GENERATOR ISOLATION:

 Announce transition to 1BEP-2 o Get acknowledgements from RO and BOP.

 Inform SM of plant status, evaluate for E-Plan.

 Request STA report to control room for Status Tree monitoring.

Examiners Note: The STA will monitor Status Trees when requested by the US/Crew. A challenge to Containment could be identified by the STA and he will make the recommendation to transition to and implement 1BFR-Z.1, Response to Containment High Pressure if containment pressure exceeds 20 psig, even if spray is already operating. Refer to page 20 for the evaluation of the crew when in 1BFR-Z.1.

BOP/RO Check Main Steam Isolation:



No Main Steam isolation valves closed



Main Steam bypass valves closed



Manually actuate Main Steamline isolation US Determine All Steam Generators are Faulted:



Check pressures in all SGs, and determine none are stable or increasing.

Implement and direct the actions of 1BCA-2.1 UNCONTROLLED DEPRESSURIZATION OF ALL SG



Announce Transition to 1BCA-2.1 o

Get acknowledgements from RO and BOP.



Inform SM of plant status, evaluate for E-Plan.

BOP Check Secondary Pressure boundary:

o Request maintenance assistance to close MSIVs.



Verify Main Steam isolation bypass valves all closed.



Check all SG PORVs Closed



Check FW Isolated to all SGs (FWI Monitor lights lit).



Check SG Blowdown Isolation and Sample valves all closed.

BOP/RO CT CA-2.1A.

Control Feed Flow to Minimize RCS Cooldown:



Determine cooldown rate in all RCS cold legs > 100 degrees F in any one hour.



Decrease feed flow to 45 gpm to each steam generator.



Report no control of feed flow to 1A Steam Generator.

o Set 1AF005E flow controller to 0%.

o Attempt to throttle 1AF013E



Dispatch operator to locally close 1AF005E.



Check Hot Leg temperatures stable or decreasing.

Comments:

Byron 2003-301 22 Scenario 03-2 Scenario No:

2 Event No.

7 Event

Description:

1A SG Steam line break inside containment resulting in a Reactor trip, all MSIVs fail open, 4 faulted SGs.

Manual actions required to establish and control AFW flow.

Time Position Applicants Actions or Behavior RO/BOP Check Status of RCPs



NO RCPs running Monitor AFW pump Suction Pressure:



1-3-E7 AF PUMP SX SUCT VLVS ARMED not lit.

RO Check Pressurizer PORVs and isolation valves:



PORV isolation valves 1RY8000A and 1RY8000B energized.



PORV 1RY455A and 1RY456 closed.



PORV isolation valves at least one open.

BOP/US Check Secondary radiation



Reset Phase A Isolation.



Request Chemistry to sample all SGs.



Check Secondary Radiation trends normal for plant conditions:



SJAE/GS Exhaust.



SG Blowdown Liquid.



Main Steamline Radiation.

CREW Determine RH pumps can be stopped:



Both RH pumps running with suction aligned to the RWST.



RCS pressure stable or increasing and > 325 psig.



Reset SI, and verify SI Actuated light not lit, and the AUTO SI BLOCKED light lit.



Stop RH pumps and place in standby.

Note: If CS is stopped in the next step, Containment pressure must be monitored for CS restart conditions (> 20 psig).

BOP/US Check if CS can be stopped:



Both CS pumps are running.



Reset CS signal.



Spray additive tank low 2 lights are not lit



Close 1CS019A and 1CS019B (per Caution prior to step 8, 1BCA-2.1).

Check Containment pressure < 15 psig.



If Containment pressure < 15 psig, stop both CS pumps.



If CS pumps stopped, Verify/Close 1CS019A and 1CS019B, and 1CS007A and 1CS007B.

Examiners Note: Scenario termination is completion of Step 8 of BCA-2.1 or Entry into BEP ES-1.3 Scenario EPlan classification is HU2

Comments:

Byron 2003-301 23 Scenario 03-2 Scenario No:

2 Event No.

7 Event

Description:

1A SG Steam line break inside containment resulting in a Reactor trip, all MSIVs fail open, 4 faulted SGs.

Manual actions required to establish and control AFW flow.

Time Position Applicants Actions or Behavior Note: The following is to be used whenever the crew implements 1BFR-Z.1, Response to High Containment Pressure.

US



Implement and direct the actions of 1BFR-Z.1:



Announces procedure transition o

Get acknowledgements from RO/BOP.



Informs SM of plant status and E-Plan evaluation.

RO/BOP Perform actions of 1BFR-Z.1 as directed:



Verify Containment isolation Phase A-Group 3 Containment isolation monitor lights lit.



Verify Containment Ventilation isolation-Group 6 Containment Vent isolation monitor lights lit.



Determines CS is required (Containment pressure has increased to > 20 psig).



Stops all RCPs if NOT previously stopped.

Comments:

Byron 2003-301 24 Scenario 03-2 Scenario No:

2 Event No.

7 Event

Description:

1A SG Steam line break inside containment resulting in a Reactor trip, all MSIVs fail open, 4 faulted SGs.

Manual actions required to establish and control AFW flow.

Time Position Applicants Actions or Behavior BOP o

Performs actions of 1BFR-Z.1 as directed:



Verifies proper CS system alignment:



CS suction valves open



1CS001A\\ 1CS009A, or 1CS001B\\ 1CS009B.



CS pump header isolation valves open



1CS007A and 1CS007B.



CS eductor spray additive valves open



1CS019A and 1CS019B.



CS eductor inlet flow control valves open



1CS010A and 1CS010B.



CS pumps running.



Group 6 Phase B lights Lit.



CS pump discharge flow > 200 gpm (1FI-CS011\\1FI-CS012)



CS eductor suction flow > 15 gpm (1FI-CS013\\ 1FI-CS-014).



CS eductor additive flow > 5 gpm (1FI-CS015\\ 1FI-CS016).



Reset CS signal.



Check Spray additive tank LO-2 lights



then closes 1CS019A and 1CS019B even if NOT lit per Caution prior to Step 3, 1BFR-Z.1 (Secondary Break only).

Align SX Cooling Towers

 All eight riser valves open



0SX163A thru 0SX163H

 All four Hot Water Basin Bypass valves closed



0SX162A thru 0SX162D

 All eight SX Cooling Tower Fans running in high speed



Verify RCFCs running in Accident Mode



Group 2 RCFC Accident Mode status lights lit.



Determines Main Steamline isolation necessary and manually actuates Main Steamline isolation and verifies Main Steam bypass valves closed. Reports all Main Steam isolation valves still open.

Comments:

Byron 2003-301 25 Scenario 03-2 Scenario No:

2 Event No.

7 Event

Description:

1A SG Steam line break inside containment resulting in a Reactor trip, all MSIVs fail open, 4 faulted SGs.

Manual actions required to establish and control AFW flow.

Time Position Applicants Actions or Behavior BOP CT:

CA-2.1A.

o Determine all SGs are faulted and controls AFW Flow:



Any SG pressure decreasing uncontrollably or completely depressurized.



Control AFW flow to 1B, 1C, and 1D SG at 45 gpm per SG by throttling 1AF005F, G, and H; or 1AF013F, G, and H.



Attempt Control of AFW to 1A SG via 1AF005E, and 1AF013E and reports no control available.

o Set potentiometer for 1AF005E to 0%.



Dispatches operator to locally throttle 1AF005E.



Checks FW isolated to all SGs



All FW Isolation Monitor lights lit.

US



Returns to step and procedure in effect:



Announces procedure transition and gets acknowledgements for RO and BOP.



Informs SM of Status.