MONTHYEARJAFP-05-0005, December 2004 Monthly Operating Report for James A. Fitzpatrick Nuclear Power Plant2005-01-12012 January 2005 December 2004 Monthly Operating Report for James A. Fitzpatrick Nuclear Power Plant JAFP-04-0186, November 2004 Monthly Operating Report for James A. FitzPatrick2004-12-0707 December 2004 November 2004 Monthly Operating Report for James A. FitzPatrick JAFP-04-0181, October 2004 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant2004-11-10010 November 2004 October 2004 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant JAFP-04-0166, September 2004 Monthly Operating Report for James a FitzPatrick Nuclear Power Plant2004-10-11011 October 2004 September 2004 Monthly Operating Report for James a FitzPatrick Nuclear Power Plant JAFP-04-0150, August 2004 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant2004-09-14014 September 2004 August 2004 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant JAFP-04-0122, July 2004 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant2004-08-0606 August 2004 July 2004 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant JAFP-04-0100, June 2004 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant2004-07-12012 July 2004 June 2004 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant JAFP-04-0086, May 2004 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant2004-06-14014 June 2004 May 2004 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant JAFP-04-0066, April 2004 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant2004-05-0707 May 2004 April 2004 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant JAFP-04-0035, February 2004 Monthly Operating Report for James a FitzPatrick2004-03-10010 March 2004 February 2004 Monthly Operating Report for James a FitzPatrick JAFP-04-0024, January 2004 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant2004-02-12012 February 2004 January 2004 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant JAFP-04-0004, December 2003 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant2004-01-12012 January 2004 December 2003 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant JAFP-03-0169, November 2003 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant2003-12-0808 December 2003 November 2003 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant JAFP-03-0154, October 2003 Monthly Operating Report for James a FitzPatrick2003-11-0707 November 2003 October 2003 Monthly Operating Report for James a FitzPatrick JAFP-03-0139, September 2003 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant2003-10-14014 October 2003 September 2003 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant JAFP-03-0130, August 2003 Monthly Operating Report for James a FitzPatrick Nuclear Power Plant2003-09-15015 September 2003 August 2003 Monthly Operating Report for James a FitzPatrick Nuclear Power Plant JAFP-03-0115, July 2003 Monthly Operating Report for James A. FitzPatrick2003-08-12012 August 2003 July 2003 Monthly Operating Report for James A. FitzPatrick JAFP-03-0097, June 2003 Monthly Operating Report for James A.Fitzpatrick Nuclear Power Plant2003-07-0909 July 2003 June 2003 Monthly Operating Report for James A.Fitzpatrick Nuclear Power Plant JAFP-03-0083, May 2003 Monthly Operating Report for James A. Fitzpatrick Nuclear Power Plant2003-06-12012 June 2003 May 2003 Monthly Operating Report for James A. Fitzpatrick Nuclear Power Plant JAFP-03-0067, April 2003 Monthly Operating Report for James A. Fitzpatrick Nuclear Power Plant2003-05-15015 May 2003 April 2003 Monthly Operating Report for James A. Fitzpatrick Nuclear Power Plant JAFP-03-0068, March 2003 Monthly Operating Report for James A. FitzPatrick, Revision 12003-05-14014 May 2003 March 2003 Monthly Operating Report for James A. FitzPatrick, Revision 1 JAFP-03-0050, March 2003 Monthly Operating Report for James A.Fitzpatrick Nuclear Power Plant2003-04-14014 April 2003 March 2003 Monthly Operating Report for James A.Fitzpatrick Nuclear Power Plant JAFP-03-0043, February 2003 Monthly Operating Report for James A. FitzPatrick2003-03-17017 March 2003 February 2003 Monthly Operating Report for James A. FitzPatrick JAFP-03-0022, January 2003 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant2003-02-14014 February 2003 January 2003 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant JAFP-03-0004, December 2002 Monthly Operating Report for James A.Fitzpatrick Nuclear Power Plant2003-01-15015 January 2003 December 2002 Monthly Operating Report for James A.Fitzpatrick Nuclear Power Plant JAFP-02-0225, October 2002 Monthly Operating Report for FitzPatrick, Rev 12002-12-12012 December 2002 October 2002 Monthly Operating Report for FitzPatrick, Rev 1 JAFP-02-0226, November 2002 Monthly Operating Report for James A.Fitzpatrick Nuclear Power Plant2002-12-12012 December 2002 November 2002 Monthly Operating Report for James A.Fitzpatrick Nuclear Power Plant JAFP-02-0211, October 2002 Monthly Operating Report for James A. FitzPatrick2002-11-12012 November 2002 October 2002 Monthly Operating Report for James A. FitzPatrick JAFP-02-0199, September 2002 Monthly Operating Report for James A. FitzPatrick2002-10-14014 October 2002 September 2002 Monthly Operating Report for James A. FitzPatrick JAFP-02-0186, August 2002 Monthly Operating Report for James a FitzPatrick Nuclear Power Plant2002-09-13013 September 2002 August 2002 Monthly Operating Report for James a FitzPatrick Nuclear Power Plant JAFP-02-0164, July 2002 Monthly Operating Report for James A. FitzPatrick2002-08-12012 August 2002 July 2002 Monthly Operating Report for James A. FitzPatrick JAFP-02-0142, June 2002 Monthly Operating Report for James A. FitzPatrick2002-07-15015 July 2002 June 2002 Monthly Operating Report for James A. FitzPatrick JAFP-02-0126, May 2002 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant2002-06-13013 June 2002 May 2002 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant JAFP-02-0107, April 2002 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant2002-05-13013 May 2002 April 2002 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant JAFP-02-0086, March 2002 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant2002-04-15015 April 2002 March 2002 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant JAFP-02-0064, Revised November 2001 Monthly Operating Report for James A. FitzPatrick2002-03-15015 March 2002 Revised November 2001 Monthly Operating Report for James A. FitzPatrick JAFP-02-0063, February 2002 Monthly Operating Report for FitzPatrick Nuclear Power Plant2002-03-15015 March 2002 February 2002 Monthly Operating Report for FitzPatrick Nuclear Power Plant JAFP-02-0036, January 2002 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant2002-02-14014 February 2002 January 2002 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant JAFP-02-0008, December 2001 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant2002-01-15015 January 2002 December 2001 Monthly Operating Report for James A. FitzPatrick Nuclear Power Plant 2005-01-12
[Table view] |
Text
Entergy Nuclear Northeast Entergy Nuclear Operations, Inc.
James A. Fitzpatrick NPP
- Entergy P.O. Box 110 Lycoming, NY 13093 Tel 315 349 6024 Fax 315 349 6480 T.A. Sullivan October 14, 2003 Site Vice President - JAF JAFP-03-0139 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Mail Station O-PI-17 Washington, DC 20555
SUBJECT:
James A. FitzPatrick Nuclear Power Plant Docket No. 50-333 September 2003 Monthly Operating Report
Dear Sir:
Enclosed is the Monthly Operating Report for the James A. FitzPatrick Nuclear Power Plant for the month of September 2003.
Should you have any questions concerning this report, please direct them to Mr. Mick I Baker, Thermal Performance Engineer, at (315) 349-6181.
Very truly yours, A T. A. SULLIVAN TAS:MB:dr Enclosure
cc: Regional Administrator U.S. Nuclear Regulatory Commission 475 Allendale Road-King of Prussia, PA 19406 Office of the Resident Inspector James A. FitzPatrick Nuclear Power Plant U.S. Nuclear Regulatory Commission P.O. Box 136 Lycoming, NY 13093 Mr. Guy Vissing, Project Manager Project Directorate I Division of Licensing Project Management U.S. Nuclear Regulatory Commission Mail stop OWFN 8C2 Washington, DC 20555 Mr. R. Toole ENN BWR SRC Operations Subcommittee Chairman 605 West Homer Street Ebensburg, PA 15931 Mr. Paul Eddy Public Service Commission Office of Electricity and the Environment 3 Empire Plaza Albany, NY 12223 JENG JAFP Files RMS (JAF)
ENTERGY NUCLEAR NORTHEAST JAMES A. FITZPATRICK NUCLEAR POWER PLANT OPERATING DATA REPORT REPORTING PERIOD: SEPTEMBER 2003 Docket No.: 50-333 Unit Name: FitzPatrick Date: October 2, 2003 Completed By : M. Baker Telephone: (315) 349-6181 APENDIX A - OPERATING DATA REPORT I. Design electrical rating (net MWE): 816
- 2. Maximum dependable capacity (gross MWE): 839 NO. DATA REQUESTED THIS YR-TO-DATE CUMULATIVE MONTH 3 Number of hours reactor was critical: 720.0 6365.0 187695.5 4 Hours generator on-line: 720.0 6227.9 182362.2 5 Unit reserve shutdown hours: 0.0 0.0 0.0 6 Net electrical energy generated (MWH): 581680.0 5105451.0 136045246.0 APPENDIX B - UNIT SHUTDOWNS NO. DATE TYPE DURATION REASON METHOD OFSSHUTTING CAUSEI
(*) IHOURS (I) DOWN TIHE REACTOR CORRECTIVE ACTIONS /
_ _____ ______ ___________ ________ (2) COM M ENTS N/A
(*) TYPE: (I) REASON: (2) METHOD:
F. FORCED A. Equipment failure (explain) 1. Manual S. SCHEDULED B. Maintenance or Test 2. Manual Trip/Scram C. Refueling 3. Automatic Trip/Scram D. Regulatory Restriction 4. Continuation E. Operator training/license examination 5. Other F. Administrative G. Operational error (explain)
H. Other (explain)
REPORTING PERIOD: SEPTEMBER 2003 Docket No.: 50-333 Unit Name: FitzPatrick Date: October 2, 2003 Completed By: M. Baker Telephone: (315) 349-6181 APPENDIX B - OPERATIONAL
SUMMARY
The FitzPatrick plant operated at or near rated power for the duration of the month of September 2003 with the exception of the following:
Note: This list does not include minor derates for rod pattern adjustments. (<20% reduction in average power level for the preceding 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />)
September 25, 2003 - 1740 While operating at 100% power the "B" reactor water recirculation (RWR) pump field breaker tripped resulting in reduced reactor coolant flow and reduction to approximately 60% power. Following repairs of the tach generator on the "B" RWR motor generator set, the plant returned to 100%
power on September 28, 2003 - 1710.