ML031400023

From kanterella
Jump to navigation Jump to search
Transmittal of the Latest Revision for Farley Emergency Plan Implementing Procedure 8.0
ML031400023
Person / Time
Site: Farley  
Issue date: 05/02/2003
From: Hudspeth J
Southern Nuclear Operating Co
To: Mcknight J
Document Control Desk, Office of Nuclear Reactor Regulation
References
FNP-197-DC FNP-0-EIP-8.0, Rev 101
Download: ML031400023 (30)


Text

- 'Southern Nuclear Operating Company, Inc.

Post Office Drawer 470 Ashford, Alabama 36312 Date: May 2, 2003 Energy to Sert?e Your WVord' FNP-197-DC Director, Office of NRC Att: Document Control Desk C/O Jim McKnight US Nuclear Regulatory Commission Washington, DC 20555

Dear Sir:

ENCLOSED IS THE LATEST REVISION FOR FARLEY NUCLEAR PLANT EMERGENCY PLAN IMPLEMENTING PROCEDURE 8.0.

FNP-0-EIP-8.0 REVISION 101 NON-EMERGENCY NOTIFICATIONS (I COPY)

PLEASE REPLACE YOUR COPY WITH THE ATTACHED REVISED COPY.

IF YOU HAVE ANY QUESTIONS, PLEASE CALL ME AT 334-899-5156 EXTENSION 3439.

Sincerely, Joey Hudspeth Document Control Supervisor CD/00 I1 Rtype:A4. 19 St

0 4 / 2 8 / 0 3 : 1 0 : 3 6

.N y

lr

-, I FNP-0-EIP-8.0 March 17, 2003 Version 101 FARLEY NUCLEAR PLANT EMERGENCY PLAN IMPLEMENTING PROCEDURE FNP-0-EIP-8.0 S

A F

E T

y NON-EMERGENCY NOTIFICATIONS R

E L

AT E

D

- PROCEDURE USAGE REQUIREMENTS PER FNP-0-AP-6 SECTIONS Continuous Use Reference Use ALL Information Use Approved:

Nuclear Plant General Manager Date Issued

- f - M_j UNCONTROLLED COPY CAUTION: This copy is rt mantelned cuffent Do not use ia a Safety Hoklasd AcMty.

i o4/28/03 8:10:36

04/28/03 8:10:36 Q t A

E D FNP-0-EIP-8.0 LIST OF EFFECTIVE PAGES PROCEDURE CONTAINS NUMBER OF PAGES Table of Contents...........

1 Body...........

14 Table 1............

1 Table 2.9 Figure 2

Version 101 Page of

04/28/03 8:10:36 SHA.RED NON-EMERGENCY NOTIFICATIONS TABLE OF CONTENTS FNP-0-EIP-8.0 Section Title 1.0 Purpose 2.0 References 3.0 General 4.0 Notification Means 5.0 Notifications For EIP-l 1, "Handling Of Injured Personnel" 6.0 Notification For EIP-13, "Fire Emergencies" 7.0 One-Hour Technical Specifications Deviation Reports [OCFR50.72(b)(1)]

8.0 One-Hour Special Nuclear Material Control and Accountability Manual, (10CFR72.74) 9.0 One-Hour Reportable Safeguards Events, IOCFR73, Appendix G 10.0 Four-Hour Reports [IOCFR50.72(b)(2)]

11.0 Four Hour Radioactive Material Reports [(IOCFR20.2201 or 2202)]

12.0 Eight-Hour Reports [(IOCFR50.72(b)(3)]

13.0 Security Quarterly Log 14.0 Fitness-For-Duty-Events (1 OCFR26.73) 15.0 Miscellaneous Notifications 16.0 48-Hour Reports [OCFR50.9(b)]

17.0 Additional Emergency Support Manager Notification 18.0 EPA Notification 19.0 Transportation Accidents TABLE I REFERENCES TABLE 2 SECURITY REPORTABIL1TY MATRIX FIGURE 1 FNP EVENT NOTIFICATION FORM Page 1 of 1 Page 1

1 1

2 3

4 5

.5 5

6 7

8 10 11 11 12 12 13 14 Version 101 I

04/28/03 8:10:36 A R E D FNP-0-EIP-8.0 NON-EMERGENCY NOTIFICATIONS 1.0 Purpose This procedure delineates the 48-hour or less reporting requirements for events that occur at the plant that do not result in the declaration of an emergency classification.

2.0 References See Table 1.

3.0 General 3.1 For declared emergencies, reporting requirements are described in FNP-0-EIP-9.0. A fire or personnel injury may require notifications from both procedures.

3.2 Prior to using this procedure to make a non-emergency report, determine if emergency declaration is required, using FNP-0-EIP-9.0.

3.3 Farley Nuclear Plant is required to notify the NRC Operations Center via the Emergency Notification System of the non-emergency events specified in paragraphs 7.0, 10.0, and 12.0 that occurred within three years of the date of discovery.

3.4 Notification Responsibility. In the event of certain occurrences at Farley Nuclear Plant, several off-site authorities must be notified. It is the responsibility of plant officials to make the notifications to the appropriate authorities. The plant officials responsible for official notifications are:

Shift Supervisor Operations Shift Superintendent Emergency Director 3.5 The On-Call Emergency Director (ED) will be informed by the Operations Shift Superintendent (OSS) of any notification required by this procedure. The OSS is responsible for notifying the ED and the Emergency Support Manager (ESM)/SNC Duty Manager for those situations listed in this procedure that require them to be notified. Notification of the ESM/SNC Duty Manager may be done by the ED if agreed to by the ED and the OSS at time of notification. The ED will determine if the Recovery Manager (RM)/EOF Manager needs to be informed of the notification immediately. If the RM/EOF Manager is to be notified immediately, the ED will make the notification or direct the OSS to do so.

Version 101

-1

04/28/03 8:10:36 C`JH R iD FNP-0-EIP-8.0 3.6 Incident Notification Form, Figure 1, will be used for transmitting Non-Emergency and Security Notifications to the NRC Operations Center (NRCOC).

3.7 Communication equipment operating instructions are located in FNP-0-EIP-8.3.

Plant personnel who are familiar with the use of the equipment are not required to have the procedure with them when using the equipment.

3.8 Emergency phone numbers are located in FNP-0-EIP-8. 1.

3.9 The plant notification roster, which contains the home addresses and phone numbers of the plant staff, is located in FNP-0-EIP-8.2.

3.10 The On-Call Memo contains the phone number and beeper number of all members of the plant staff who are on call. This memo is located at the front of the Emergency Phone Directory, FNP-0-EIP-8. 1.

3.11 If the NRCOC is being notified, notify the NRC resident in association with that notification. Notify the NRC resident at other times when it is deemed appropriate by the ED or on shift supervision. The notification of the resident has no specific time requirement.

4.0 Notification Means 4.1 The NRCOC shall be contacted by use of the FTS Emergency Notification System (ENS) for notifications required in one hour, four hours, or eight hours of the occurrence or event.

4.2 Phone numbers for use on the FTS ENS are located on labels on the ENS phones or can be found in FNP-0-EIP-8. 1.

4.3 For ENS failures, any other FTS phone located in the TSC and the EOF can be used to contact the NRCOC by dialing the same numbers as listed on the ENS phones.

Refer to FNP-0-EIP-8. 1 for phone locations.

4.4 For ENS or FTS failures, any commercial phone line can be used to contact the NRCOC by accessing an outside line, dialing I, and then the phone number as listed on the ENS phones.

4.5 Other agencies or individuals can be contacted by using the commercial phones. The phone numbers are located in FNP-0-EIP-8. 1.

Version 101 04/28/03 8:10:36 E D FNP-0-EIP-8.0 5.0 Notifications for EIP-I 1, "Handling of Injured Personnel" NOTE:

During a declared emergency the Emergency Director will direct all of the EIP-1l1 notifications. When there is no declared emergency the OSS should continue with the ED notifications until the ED arrives on site or otherwise relieves the OSS of the responsibility.

5.1 Ensure all required FNP-0-EIP-1 1.0, Guideline 1, notifications are completed.

5.2 Notify the Emergency Support Manager/ SNC Duty Manager 5.3 Notify the Recovery Manager/EOF Manager if required by the On-Call ED.

5.4 Notify office of Alabama Radiation Control if a radiation casualty is to be transported to an off-site medical facility.

5.5 Notify the NRC, per step 12.5, if the injury requires the transport of a radioactively contaminated person to an off-site medical facility. If the NRCOC is being notified, notify the NRC resident in conjunction with that notification.

5.6 Occupational Safety and Health Administration (OSHA) shall be notified within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> after learning of a single fatality or in-patient hospitalization of three or more employees as a result of a single work related accident. This requirement applies to any fatality or hospitalization that occurs within 30 days of the work related accident.

The OSHA phone number is located in FNP-0-EIP-8. 1.

Report the establishment name, contact name and phone number, number of individuals involved, location, time, and a brief description of the incident.

5.7 Refer to the following steps if a transportation accident is involved with an injury or fatality:

Step 10.4 Step 17.4 Step 17.7 Step 19.0 5.8 Rtefer to the following step if radiation overexposure has occurred or is suspected.

Step 11.2 5.9 If the NRC has not been notified of the event for other reasons refer to step 14.0 for possible additional notification requirements.

Version 101 04/28/03 8:10:36 S H A R E D~_1k, 1

FNP-0-EIP-8.0 6.0 Notification for EIP-13, "Fire Emergencies" i

CAUTION:

A PLANT FIRE MAY REQUIRE AN EMERGENCY DECLARATION, DEPENDING ON WHAT EQUIPMENT HAS FAILED.

NOTE:

During a declared emergency, the Emergency Director will direct all of the EIP-13 notifications. When there is no declared emergency the OSS should continue with the ED notifications until the ED arrives on site or otherwise relieves the OSS of the responsibility.

NOTE:

Notifications are required for all plant fires including small fires and hydrogen vent stack fires. EXCEPTION: Notifications are not required for intentionally set fires at the Fire Training Facility.

6.1 The OSS shall ensure the following are notified:

6.1.1 Plant Fire Brigade if needed.

6.1.2 When requesting support for Dothan Fire Department (DFD) to FNP, provide the responder with the route to take to the site to avoid unnecessary radiological exposure, if applicable.

6.1.3 Dothan Fire Department, if needed. Call DFD and request that DFD call back to verify the request for assistance. When DFD calls, verify the need for assistance.

6.1.4 Plant Security, if the fire involves breaches of plant security or if off-site agencies are to be escorted on-site.

6.1.5 The On-Call Emergency Director.

6.1.6 The Plant Fire Marshall, or in the event the Fire Marshall cannot be reached, Engineering Support supervision.

6.1.7 When requesting support from Air Products to FNP, provide the responder with the route to take to the site to avoid unnecessary radiological exposure, if applicable.

6.1.8 Air Products, if the emergency involves a liquid hydrogen tank, a liquid oxygen tank, or associated use systems.

6.2 The ED shall notify:

6.2.1 Appropriate portions of the Plant Emergency Organization.

Version 101 04/28/03 8:10:36

-H E

FNP-0-EIP-8.0 6.2.2 Emergency Support Manager/SNC Duty Manager, if PCB transformers are involved in the fire-related incident. Provide ESM/SNC Duty Manager with appropriate Enviromnental Protection Agency notification information from FNP-0-EIP-13.0.

6.2.3 NRC (notification to be made as required by appropriate emergency classification.) If the NRCOC is being notified, notify the NRC resident in conjunction with that notification.

NOTE:

See Step 8.0 for One-Hour Special Nuclear Material Reports. See Step 9.0 for One-NOTE:

Hour Reportable Safeguards Events.

7.0 One-Hour Technical Specifications Deviation Report [IOCFR 50.72(b)(1)].

If not reported as a declaration of an emergency class per FNP-0-EIP-9.0, the NRC Operation Center and the Emergency Support Manager/SNC Duty Manager shall be notified by the OSS or the Emergency Director within one hour of the occurrence of: any deviation from the plant's Technical Specifications authorized pursuant to 10CFR50.54(x) (i.e., a deviation from Technical Specifications dictated by emergency conditions. (Figure 1 will be used): [OCFR 50.72(b)(1)]

Notify the NRC resident in conjunction with this notification.

8.0 One-Hour Special Nuclear Material Control and Accountability Manual, (IOCFR72.74)

The OSS or Emergency Director shall notify the NRC Operations Center and Emergency Support Manager/SNC Duty Manager within one hour of occurrence of any of the following:

Notify the NRC resident in conjunction with this notification.

8.1 Any accidental criticality (IOCFR72.74.a).

8.2 Any loss of licensed special nuclear material as defined in Reference 10 (IOCFR72.74.a).

9.0 One-Hour Reportable Safeguards Events, OCFR73, Appendix G The OSS or the Emergency Director shall notify the NRC Operations Center and the Emergency Support Manager/SNC Duty Manager within one hour of the occurrence of the events classified as one hour in Table 2 (SECURITY REPORTABILITY MATRIX).

The Licensing Supervisor will prepare a follow-up written report per FNP-0-AP-30. The report shall be documented by completion of the applicable portions of Figure 1.

Notify the NRC resident in conjunction with this notification.

Version 101

-5

04/28/03 8:10:36 A Rlir j

3 FNP-0-EIP-8.0 10.0 Four-Hour 50.72 Reports [(1 OCFR50.72(b)(2)].

If not reported as a declaration of an emergency class or as a one hour non emergency report, the NRC Operations Center and Emergency Support Manager/SNC Duty Manager shall be notified by the OSS or the Emergency Director as soon as practical and in all cases within four hours of the occurrence of any of the following (Figure 1 will be used):

Notify the NRC resident in conjunction with this notification.

10.1 The initiation of any nuclear plant shutdown required by Technical Specifications.

[ 1 OCFR50.72(b)(2)(i)]

10.2 Any event that results or should have resulted in Emergency Core Cooling System (ECCS) discharge into the reactor coolant system as a result of a valid signal except when the actuation results from and is part of a pre-planned sequence during testing or reactor operation. [(1 OCFR50.72(b)(2)(iv)(A)].

10.3 Any event or condition that results in actuation of the reactor protection system (RPS) when the reactor is critical except when the actuation results from and is part of a pre-planned sequence during testing or reactor operation.

[1 OCFR50.72(b)(2)(iv)(B)]

I NOTE:

Paragraph 10.4 also satisfies section 4.1 of the FNP Environmental Protection l

Plan.

I 10.4 Any event or situation related to the health and safety of the public or onsite personnel or to protection of the environment, for which a news release is planned or notification to other government agencies has been or will be made.

[ I OCFR50.72(b)(2)(xi)1 Examples:

An onsite fatality - See section 5 for possible additional reporting requirements.

Inadvertent release of radioactively contaminated materials.

Notification of governmental agencies required by FNP-0-AP-60.

Version 101 04/28/03 8:10:36 STHARIED FNP-0-EIP-8.0 11.0 Four Hour Radioactive Material Reports [(10CFR20.2201 or 2202)].

If not reported as a declaration of an emergency class or as a one hour non emergency report, the NRC Operations Center and Emergency Support Manager/SNC Duty Manager shall be notified by the OSS or the Emergency Director as soon as practical and in all cases within four hours of the occurrence of any of the following (Figure 1 will be used):

Notify the NRC resident in conjunction with this notification.

11.1 Any loss or theft of licensed material in an aggregate quantity equal to or greater than 1000 times the quantity specified in Appendix C of 10CFR20 and under such circumstances that it appears that an exposure could result to persons in unrestricted areas. Immediate notifications made under this paragraph satisfies the requirements of paragraph a (1) of IOCFR20.2201.

NOTE:

Steps 11.2 and 11.3 are actually 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> notification requirements. The four hours notification requirements are approximately 5 times these values. Farley Nuclear Plant has taken the position that we will make the four hours notification if either limit is exceeded.

11.2 Any event involving licensed material that may have caused or threaten to cause an individual to receive any of the doses listed in the below table. Notifications made under this paragraph satisfy the requirements of paragraphs a (1) and b (1) of I OCFR20.2202. See section 5 for possible additional reporting requirements.

TOTAL EYE DOSE SHALLOW HOT PARTICLES (See Information EFFECTIVE DOSE DOSE Notice 90-48)

EQUIVALENT EQUIVALENT IN CONTACT NOT IN CONTACT WITH SKIN WITH SKIN TEDE LDE SKIN OR WHOLE BODY OR EXTREMITIES EXTREMITIES 15 REM 15 REM 50 REM 75 ci-hr 50 RAD 11.3 The release of radioactive material, inside or outside of a restricted area, so that, had an individual been present for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, the individual could have received an intake in excess of one occupational annual limit on intake (the provisions of this paragraph do not apply to locations where personnel are not normally stationed during routine operations, such as hot-cells or process enclosures). Notifications made under this

-paragraph satisfy the requirements of paragraphs a (2) and b (2) of 10CFR20.2202.

See section 5 for possible additional reporting requirements.

Version 101 I

04/28/03 8:10:36 Sk.. {A ED FNP-0-EIP-8.0 12.0 Eight-Hour Reports [(I OCFR50.72(b)(3)].

If not reported as a declaration of an emergency class or as a one hour or four hour non emergency report, the NRC Operations Center and Emergency Support Manager/SNC Duty Manager shall be notified by the OSS or the Emergency Director as soon as practical and in all cases within eight hours of the occurrence of any of the following (Figure 1 will be used):

Notify the NRC resident in conjunction with this notification.

12.1 Any event or condition that results in the condition of the nuclear power plant, including its principal safety barriers being seriously degraded.

[(l1OCFR50.72(b)(3)(ii)(A)]

12.2 Any event or condition that results in the nuclear power plant being in an unanalyzed condition that significantly degrades plant safety.

[(I OCFR50.72(b)(3)(ii)3(B)]

12.3 Any event or condition that results in valid actuation of any of the systems listed below except when the actuation results from and is part of a pre-planned sequence during testing or reactor operation. [(1 OCFR50.72(b)(3)(iv)(A)]

(I) Reactor protection system (RPS) including reactor trip. Actuation of the RPS when the reactor is critical is reportable under step 10 as a four hour report.

(2) General containment isolation signals affecting containment isolation valves in more than one system or multiple main steam isolation valves (MSIVs).

(3) Emergency core cooling systems (ECCS) including: high-head and low-head injection systems.

(4) Auxiliary feedwater system.

(5) Containment heat removal and depressurization systems, including containment spray and fan cooler systems.

(6) Emergency ac electrical power systems, including emergency diesel generators (EDGs).

Version 101 04/28/03 8:10:36

[

FNP-0-EIP-8.0 12.4 Any event or condition that at the time of discovery could have prevented the fulfillment of the safety function of structures or systems that are needed to:

[(1 OCFR50.72(b)(3)(v)]

(1) Shut down the reactor and maintain it in a safe shutdown condition, (2) Remove residual heat, (3) Control the release of radioactive material, (4) Mitigate the consequences of an accident.

Events covered in this step may include:

1.

one or more procedural errors,

2.

equipment failures, 3

discovery of design, analysis, fabrication, construction, and/or procedural inadequacies.

However, individual component failures need not be reported pursuant to this step if redundant equipment in the same system was operable and available to perform the required safety function.

12.5 Any event requiring the transport of a radioactively contaminated person to an off-site medical facility for treatment [(10CFR50.72(b)(3)(xii)]. See step 5 for possible additional reporting requirements.

12.6 Any event that results in a major loss of emergency assessment capability, off-site response capability, or offsite communications capability.

[(I OCFR50.72(b)(3)(xiii)]

Examples:

12.6.1 Emergency Response Facilities (one of the following inaccessible or unusable and the facility cannot be restored within 75 minutes of being required [(I OCFR50.72(b)(3)(xiii)].

TSC EOF Version 101 g9

04/28/03 8:10:36 S 17iAE tA

-J FNP-0-EIP-8.0 12.6.2 Emergency communications facilities and equipment (one of the following inoperable for over one hour) [(I OCFR50.72(b)(3)(xiii)].

ENS (Refer to FNP-O-EIP-8.3 to report any FTS failure to the NRC to start repairs for the failed system.)

ENN, loss of ability to communicate with the State of Alabama (Dothan AND Montgomery)

ENN, loss of ability to communicate with the State of Georgia (Blakely AND Atlanta)

Microwave communications via Met Tower (total loss)

Land line communications via Ashford Phone Company and the Dothan Phone company (total loss) 12.6.3 Public Prompt Notification System [(I OCFR50.72(b)(3)(xiii)].

Tone alert radio system inoperable for one hour.

Siren control panel or repeater at Houston County Courthouse inoperable for one hour.

Simultaneous loss of Gordon, Ashford, and Columbia sirens for one hour.

Notification that the tone alert radio system or all three sirens have failed their functional test. If it is determined that the eight-hour report was not necessary, then a corrected report is to be made to the NRC.

On site and off-site equipment failures will be reported to Information Resources.

12.6.4 Emergency Assessment Capability [(I OCFR50.72(b)(3)(xiii)].

Loss of multiple plant monitors necessary for accident assessment (required to use action statement F or G of Post Accident Monitor Technical Specification 3.3.3 for four or more functions listed in table 3.3.1).

Loss of the SPDS system and other assessment equipment greater than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

Version 101 04/28/03 8:10:36 FNP-0-EIP-8.0 13.0 Security Quarterly Log. Security Supervision shall record certain events in the Reportable Safeguards Event Quarterly Log within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of occurrence. Security Supervision will periodically have a copy of Safeguards Event Quarterly Log entries transmitted to Document Control for retention.

Events that are to be recorded in the Security Quarterly Log are described in Table 2 (SECURITY REPORTABILITY MATRIX).

14.0 Fitness-For-Duty Events [10CFR26.73, NUREG-1385]. The OSS or the Emergency Director shall notify the NRC Operations Center and Emergency Support Manager/SNC Duty Manager within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of the occurrence of any of the following. The report shall be documented by completion of the applicable portions of Figure 1.

Notify the NRC resident in conjunction with this notification.

14.1 Sale, use or possession of illegal drugs within the protected area.

14.2 Commission of any of the following acts by a licensed operator, senior operator or supervisory employee (SNC or contractor).

14.2.1 Sale, use,-or possession of a controlled substance.

14.2.2 Confirmed positive test for a controlled substance.

14.2.3 Use of alcohol within the protected area.

14.2.4 Determination that the employee is unfit for scheduled work due to the consumption of alcohol.

14.3 Fitness-for-duty events shall be reported under 10CFR26.73 (9.3), rather than under 10CFR73.71 (9.1).

15.0 Miscellaneous Notifications 15.1 Reactor Trip Breaker Failures (Generic Letter 83-28 Commitment). Other circumstances requiring NRC notification within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> by commercial telephone.

15.1.1 Any failure of the UV trip attachment on either a reactor trip breaker or bypass breaker to open or close during functional testing or while in service.

15.1.2 Any failure of a reactor trip breaker or bypass breaker to open on demand, either in service or during surveillance testing by either the under voltage trip or the shunt trip.

Version 101 4/28/03 8:10:36 SH ARE D FNP-0-EIP-8.0 15.2 Overdue Nuclear Fuel Transport Vehicle (OCFR73.67).

The OSS shall notify the On-Call Reactor Engineer when a nuclear fuel transport vehicle is over four hours overdue, based on its scheduled arrival time. The On-Call Reactor Engineer will initiate a trace investigation to determine if the shipment is lost, stolen or diverted.

15.3 Inadvertent Siren/Tone Alert Radio Activation The OSS or Emergency Director shall notify the Houston County Emergency Management Agency (EMA) upon an inadvertent activation of the tone alert radio system, or an inadvertent activation of the Ashford, Columbia, or Gordon alert siren.

Refer to FNP-0-EIP-2.0 for additional requirements.

16.0 48-Hour Reports (10CFR50.9 (b)), Significant Event, Condition or Information)

If not reported under another paragraph of this procedure, the NRC Operations Center and Emergency Support Manager/SNC Duty Manager shall be notified by the OSS or the Emergency Director within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> (or within two working days) of an event, condition, or newly discovered information that has a significant implication for public health and safety (Figure 1 will be used). Such an event, condition, or new information is reportable under I OCFR50.9 (b) if it meets both of the following criteria:

Notify the NRC resident in conjunction with this notification.

16.1 It is not reportable under any other NRC notification or updating requirement.

16.2 It has a significant implication for public health and safety or common defense and security. Significant means that:

16.2.1 It is relevant to the NRC in its regulatory capacity. Information relating solely to economics, labor relations or industrial safety may not be relevant to the NRC's nuclear safety role.

AND 16.2.2 It is material, in that it would have a tendency to influence the NRC on the issue of regulatory compliance.

17.0 Additional Emergency Support Manager/SNC Duty Manager Notifications To ensure that the appropriate company upper management positions receive timely reports concerning unusual significant events, the guidelines listed below shall be used.

The OSS (unless specifically relieved of such responsibility on an event-by-event basis by the Nuclear Plant General Manager or his alternate, who is designated at the time as the On-Call Emergency Director) shall verbally report the following events to the On-Call Emergency Support Manager/SNC Duty Manager:

Version 101 04/28/03 8:10:36 R E I

rDI.

Ei FNP-0-EIP-8.0 17.1 Any initiation of an event as outlined sections 7, 8, 9, 10, 11, 12 and 16 of this procedure (taken from 10CFR50, paragraph 50.72).

17.2 "Limiting conditions of operations" (LCOs), as contained in the Technical Specifications that could require unit shutdowns within the next twelve (12) hours.

17.3 Unscheduled shutdowns or power reductions to below 30%.

17.4 Serious personnel injuries. See section 5 for possible additional reporting requirements.

17.5 Events of high public or news media interest.

17.6 False siren activation.

17.7 Transportation incidents (49CFRI 71.15) involving radioactive materials or new fuel in which: (See step 5 for possible additional reporting requirements.)

17.7.1 A person is killed.

17.7.2 A person receives injuries requiring medical treatment.

17.7.3 Measurable property damage occurs to the carrier or to some other entity.

17.7.4 Fire, breakage, spillage, or suspected radioactive contamination occurs.

17.7.5 A continuing danger of life exists at the scene of the incident.

17.7.6 The Emergency Director determines that it is in SNC or APCo's best interest that off-site agencies be notified.

17.7.7 If unable to contact the Emergency Support Manager/SNC Duty Manager within four hours, the Emergency Director shall notify the Department of Transportation (DOT) and American-Nuclear Insurers (ANI).

17.8 Other events that are not exactly specified above, but which are considered at the time of the occurrence to be of possible concern to upper management.

18.0 EPA Notifications 18.1 Reporting of natural oil spills, synthetic oil spills and polychlorinated biphenyl (PCB) spills is addressed in-FNP-0-AP-60.

18.2 Reporting of releases, fires or explosions which involve hazardous wastes is addressed in FNP-0-AP-60.

18.3 Reporting of releases of hazardous substances or extremely hazardous substances (including radionuclides) is addressed in FNP-0-AP-60.

Version 101 04/28/03 8:10:36 P..R Ai FNP-0-EIP-8.0 INOTE:

Refer to step 17.7 of this procedure for other notification requirements.

19.0 Transportation accidents involving hazardous substances or extremely hazardous substances (including radioactive materials) - see section 5.0 for possible additional reporting requirements involving fatalities or hospitalization.

19.1 Ensure that the Department of Transportation/Coast Guard National Response Center has been notified in the event that hazardous materials cause one or more of the following (this is driver/carrier responsibility):

19.1.1 A person is killed.

19.1.2 A person receives injuries requiring hospitalization.

19.1.3 Estimated carrier or other property damage exceeds $50,000.

19.1.4 Fire, breakage, spillage, or suspected radioactive contamination occurs involving shipment of radioactive material.

19.1.5 Fire, breakage, spillage, or suspected contamination occurs involving shipment of etiologic agents (includes sewage and medical waste).

19.1.6 Continuing danger to life exists at the scene of the incident.

19.2 Notify the Emergency Director.

19.3 Notify the On-Call Environmental Supervisor (non-rad shipment) or On-Call HP Manager/Supervisor (rad shipment) to prepare a follow-up report per 49CFR17 1.15 and to assess whether APCo should provide support at the scene of the accident.

19.4 Notify the Emergency Support Manager/SNC Duty Manager and request that the ESM/SNC Duty Manager notify SNC Environmental Services to provide support.

Version 101 04l28/03 8:10:36 3 i {A 1FR ED FNP-0-EIP-8.0 TABLE 1 REFERENCES

1.

Joseph M. Farley Nuclear Plant Emergency Plan

2.

FNP-0-EIP-3.0, Duties of the Emergency Director

3.

FNP-0-EIP-9.0, Emergency Classification and Actions

4.

FNP-0-EIP-10.0, Evacuation and Personnel Accountability

5.

FNP-0-EIP-1 1.0, Handling of Injured Personnel

6.

FNP-O-EIP-13.0, Fire Emergencies

7.

FNP-0-AP-60, Oil Spill Prevention Control and Countermeasures Plan

8.

10CFR50.72, ENS Notification Criteria

9.

10CFR73.7 1, Reportable Safeguards Events

10.

FNP-0-SNM-O, Special Nuclear Material Control and Accountability Manual

11.

IOCFR50.9, Reporting Requirements (NS-88-0145)

12.

49CFR171.15, Hazardous Materials Incidents

13.

1 OCFR26, Fitness for Duty

14.

Reporting of Safeguards Events (USNRC Generic Letter 91-03)

15.

Enforcement Policy for Hot Particle Exposure (Information Notice 90-48)

16.

29CFR part 1904 - Reporting of Fatality or Multiple Hospitalization Incidents

17.

NUREG-1022 Event Reporting Guidelines

18.

Regulatory Guide 5.6.2, Nov. 1987, Reporting of Safeguards Events Page 1 of 1

04/28/03 v:36 iFr--EIP-8.0 TABLE 2 SECURITY REPORTABILITY MATRIX The time constraints to implement compensatory measures and initiate NRC reports typically start at the time the event occurs. If the exact time cannot be determined, the time of event discovery by on-site security management or an equivalent level of plant management will be used for initiating compensatory measures and event reporting. Events should be properly compensated within 10 minutes of discovery or within the time prescribed in the Security Plan. However, if extenuating circumstances prevent compensation within that time, the event need not be reported promptly provided there was no malevolent intent, nothing adverse resulted from the delay, and appropriate measures were taken to ensure necessary action in the future.

Version 101 Event Description System/Component Status Compensatory Measures Reportability Taken Within 10 Minutes of the Event Discovery A.

THREATS OR ACTS

10CFR73, ppendix G
1.

Any event in which a person has Theft or unlawful diversion of N/A One Hour report per step 9.0 committed or caused, or attempted to any special nuclear material at commit or cause, or has made a FNP or of nuclear fuel enroute to credible threat to commit or cause:

FNP

2.

Any event in which a person has Significant physical damage to N/A One Hour report per step 9.0 committed or caused, or attempted to either FNP unit, spent fuel pool commit or cause, or has made a or nuclear fuel transport vehicle credible threat to commit or cause:

to the extent that it cannot perforn its normal function I

Page of 9

04/28/03 8:iu:36 C.

FNi'-0-EIP-8.0 TABLE 2 SECURITY REPORTABILITY MATRIX Event Description System/Component Status Compensatory Measures Reportability Taken Within 10 Minutes of the Event Discovery B.

LOSS OF VA BARRIER SYSTEM/COMPONENT I OCFR73. Appe dix G

1.

VA Barrier(s) (1)

Physically/Forcibly Breached N/A One Hour report per step 9.0 and or Doors(s)

Design flaw or vulnerability Yes Log per step 12.0 in VA barrier No One Hour report per step 9.0

2.

Keycard and Alarned-Not Locked Yes Log per step 12.0 Alarmed Doors(s)

No One Hour report per step 9.0 Locked-Not Alarned Yes Log per step 12.0 No One Hour report per step 9.0 Not Alarmed-Not Locked Yes(2)

Log per step 12.0 No One Hour report per step 9.0

3.

Card Reader Failure allows unauthorized Yes Log per step 12.0 Failure access through door.

No One Hour report per step 9.0 C.

LOSS OF PA BARRIER SYSTEM/COMPONENT I OCFR73, Appendix G

1.

PA Barrier(s) (1)

Physically/Forcibly Breached N/A One Hour report per step 9.0 or Turnstiles(s)

Design flaw or vulnerability Yes Log per step 12.0 in PA barrier No One Hour report per step 9.0

2.

Turnstile(s)/PA Alarmed-Not Locked Yes Log per step 12.0 Entry Doors(s)

No One Hour report per step 9.0 Locked-Not Alarmed Yes Log per step 12.0 No One Hour report per step 9.0 Not Alarrned-Not Locked Yes Log per step 12.0 No One Hour report per step 9.0 Version 101 i

;

`

't 11 11

_i'

, _j 4

I I 1, A

1 'I" f

" I t,, _.

,.,

11.1-Page 2 of 9

C 04/28/03 8i nv:36 I.

.9

(

FNr-0-EIP-8.0 TABLE 2 SECURITY REPORTABILITY MATRIX Event Description System/Component Status Compensatory Measures Reportability Taken Within 10 Minutes of the Event Discovery D.

LOSS OF INTRUSION ALARM AND/OR ASSESSMENT CAPABILITIES 10CFR73, Appendi G

1.

Loss of Microwave or Infrared (one or Inoperable/ Out of Service due to Yes Log per step 12.0 more zones)

Failure/Maintenance/Repair/Test No One Hour report per step 9.0 ing

2.

Loss of CCTV Surveillance (one or Inoperable/ Out of Service due to Yes Log per step 12.0 more cameras/monitors)

Failure/Maintenance/Repair/

No One Hour report per step 9.0 Testing

3.

Loss of Remote Control Panel (RCP),

Keycard/Alarm or Zone Yes Log per step 12.0 Local Control Panel (LCP) or Node Inoperable/Out of Service due to No One Hour report per step 9.0 Panel (Total loss)

Failure/Maintenance/Repair/Test ing

4.

Loss of RCP, LCP, or Node Panel Keycard/Alarn or Zone Yes Log per step 12.0 (Partial)

Inoperable/Out of Service due to No One Hour report per step 9.0 Failure/Maintenance/Repair/

Testing

5.

Loss of both Inoperable/Out of Service due to Yes Log per step 12.0 computer processors Failure/Maintenance/Repair/Test No One Hour report per step 9.0 ing

6.

Loss of one computer processor Fail over to Backup Yes(2)

Log per step 12.0 No Log per step 12.0

7.

Loss of CAS/SAS Alternate Alarm Station operable N/A Log per step 12.0 Both Stations inoperable Yes Log per step 12.0 No One Hour report per ste 9.0

8.

Loss of PA lighting Inoperable/Out of Service due to Yes Log per step 12.0 (Total or Partial)

Failure/Maintenance/Repair/Test No One Hour report per step 9.0 ing Momentary Loss of PA lighting N/A Log per step 12.0 Version 101 Page 3 of 9

04/28/03 8u:lU36 f'

(VE FNlJ'0-EIP-8.0 TABLE 2 SECURITY REPORTABILITY MATRIX Event Description System/Component Status Compensatory Measures Reportability Taken Within 10 Minutes of the Event Discovery E.

LOSS OF POWER IOCFR73, Appendix G

1.

Loss of AC power Standby Power maintains Yes Log per step 12.0 (Total or Partial) integrity.

No One Hour report per step 9.0

2.

Loss of Standby Power during loss of Total power loss N/A One Hour report per step 9.0 power F.

LOSS OF LLEA COMMUNICATIONS I OCFR73, Appendix G

1.

Partial Loss At least one method of N/A Log per step 12.0 communicating operable

2.

Total Loss All on-site communications N/A One Hour report per step 9.0 capabilities Inoperable/Out of Service due to Failure/

Maintenance/Repair/Testing G.

INTERRUPTION OF NORMAL OPERATIONS OCFR73, App)endix G I.

Fire or Explosion of suspicious or N/A T

N/A One Hour report per step 9.0 unknown origin within the PA, including the Isolation Zone

2.

Suspicious explosive device N/A N/A One Hour report per step 9.0 discovered

3.

Confirmed unauthorized use of, or N/A N/A One Hour report per step 9.0 vandalism or tampering with machinery, components or controls, including the security system/components

4.

Credible bomb or extortion threat N/A N/A One Hour report per step 9.0

5.

Unsubstantiated bomb or extortion N/A N/A Log per step 12.0 threat

6.

Mass demonstrations or civil N/A N/A One Hour report per step 9.0 disturbance near the site which may pose a threat to the facility G.

INTERRUPTION OF NORMAL OPERATIONS (Continued Next Page)

Page 4 of 9 Version 101

04/28/03 8:1u:36

(,

FNP-0-EIP-8.0 TABLE 2 SECURITY REPORTABILITY MATRIX Event Description System/Component Status Compensatory Measures Reportability Taken Within 10 Minutes of the Event Discovery G.

INTERRUPTION OF NORMAL OPERATIONS 10CFR73. Appendix G (Continued from previous age)

7.

An assault on the facility, regardless of N/A N/A One Hour report per step 9.0 whether perimeter penetration is achieved.

8.

Attempted or confirmed intrusion, or N/A N/A One Hour report per step 9.0 actual entry of an unauthorized individual into PA/VA

9.

Discovery of/or attempted malevolent N/A N/A One Hour report per step 9.0 introduction of weapons, explosives, or incendiary devices in/into the PA.

10.

Discovery of contraband inside the PA N/A N/A Log per step 12.0 that is not a significant threat.

NOTE:

FFD events wil be reported using step 14 of the main body of the procedure unless the requirements of Note 6 below are met.

The requirements of 10 CFR 26.73 are applicable to item 11 regarding controlled substances. See Note 6 below.

11.

Reasonable suspicion of illegal use, N/A N/A One Hour report per step 9.0 sale, possession, or introduction of controlled substances(s) on-site or other criminal acts involving personnel with unescorted access which may directly affect operations

12.

Suspension of Safeguards controls by N/A Yes Log per step 12.0 the Shift Superintendent during No One Hour report per step 9.0 Emergencies including a Security Emergency.

Version 101 I

Page of 9

C 04/28/03 8:iv:36

(

  • -i0-EIP-8.0 TABLE 2 SECURITY REPORTABILITY MATRIX Event Description Systen/Component Status Compensatory Measures Reportability Taken Within 10 Minutes of the Event Discovery H.

SECURITY FORCE PERSONNEL RELATED 10CFR73, Annendix G

1.

Unavailability of minimum number or N/A Yes Log per step 12.0 impending strike of Security No One Hour report per step 9.0 Personnel.

2.

Loss of Security Retrieved within one hour Yes Log per step 12.0 Weapon On-site No One Hour report per step 9.0

3.

Security Officer asleep on Post N/A Yes Log per step 12.0 No One Hour report per step 9.0 I.

PROCEDURAL RELATED FAILURE IOCFR73. Appendix G

1.

Loss or Theft of Safeguards N/A Yes One Hour report per step 9.0 Information which could Not significant or would not Log per step 12.0 SIGNIFICANTLY assist radiological assist sabotage

2.

Inadvertent/accidental removal of N/A Yes (4)

Log/Non-Event(5) security keys from PA No

3.

Discovery of intentionally falsified N/A N/A One Hour report per step 9.0 identification badges or key cards

4.

Unauthorized use of, unaccounted for, N/A Yes (4)

Log per step 12.0 lost, or stolen badge that could allow No One Hour report per step 9.0 unauthorized access to PAs or VAs

5.

Visitor without Escort N/A Yes Log/Non-Event(5)

No Log (5)

6.

Individual authorized only PA access N/A Yes Non-Event is incorrectly issued a badge granting No Log VA access (initial badge issue), but does not enter any VAs or does not enter any VAs with malevolent intent.

Version 101 Page 6 of 9

f 04/28/03 8S.iO:36 4

(

Ft4i--0-E1P-8.0 TABLE 2 SECURITY REPORTABILITY MATRIX Event Description System/Component Status Compensatory Measures Reportability Taken Within 10 Minutes of the Event Discovery J.

MISCELLANEOUS I.

Discovery of off-site criminal acts by N/A Yes Log per step 12.0 personnel with unescorted access No One Hour report per step 9.0 which could cause concern about their trustworthiness and reliability or a program weakness.

2.

Any criminal act by a licensee N/A Yes Log per step 12.0 employee committed offsite, which No One Hour report per step 9.0 receives media attention, and has the potential for affecting the radiological safety of licensee activities..

3.

Any other threatened attempted, or N/A Yes Log per step 12.0 committed act not previously defined No One Hour report per step 9.0 having potential for reducing Physical Security Effectiveness 4

Vehicle Barrier System Degradation N/A For short time period (not to Log per step 12.0 exceed 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />)

For longer time period (not to Log per step 12.0 exceed 30 days)

Version 101 Page 7 of 9

04/28/03 8 O:36 A.

(

(

E.0 TABLE 2 SECURITY REPORTABILITY MATRIX Event Description System/Component Status Compensatory Measures Reportability Taken Within 10 Minutes of the Event Discovery K

PARTIAL FAILURE OF ACCESS CONTROL PROGRAM

1.

A badged person inadvertently enters N/A Yes Log per step 12.0 the PA through a vehicle gate before No One Hour report per step 9.0 being searched.

2.

A badged person walks into a VA N/A N/A Log per step 12.0 behind another person without using a badge, if the improper entry was inadvertent or without malevolent intent.

3.

A person enters a VA to which he is N/A N/A Log per step 12.0 authorized unescorted access by inadvertently using a badge intended for another person who is authorized access to the area.

L.

INCOMPLETE PRE-EMPLOYMENT SCREENING RECORDS (to include falsification and willful omission from the screening application)

1.

Unescorted access of the individual N/A Reportability may need to be cancelled or suspended Requirements until the identified anomaly is resolved. If the licensee deternines Discovery of significant One Hour report per step 9.0 that unescorted access would have information, access is denied and been denied based on developed the event will be reported to the information that is viewed as NRC within 1-hour.

significant as outlined in Corporate Security Department (CSD - 3)

If less significant inforrnation, Log per step 12.0 Procedure, recorded in the security safeguards log within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

Version 101 d

Page 8 of 9

C.

4



04/28/03 8iu:36

(*j TABLE 2 SECURITY REPORTABILITY MATRIX FN -u-EIP-8.0 Version 101 NOTES (1)

Examples include floor or wall plugs, bisco seals, barriers in HVAC ducts, etc.

(2)

To be properly compensated, measures must be in place within 10 minutes of event discovery.

(3)

Events reportable under 50.72 or 50.73 do not require duplicate reports under 73.71 (4)

To be properly compensated, both invalidating the badge and initiating actions to ensure no unauthorized use of the badge must occur within 10 minutes of event discovery by on-site security personnel.

(5)

May be a loggable event depending on circumstances.

(6)

A significant FFD event must be reported under the provisions of 10 CFR 26.73, but need not be reported under 10 CFR section 73.71. FFD program performance data must be submitted under provisions of 10 CFR 26.7 1(d). In those rare cases where an event with safeguards significance is caused by an FFD event, the FFD aspects must be submitted to the NRC in accordance with 10 CFR Part 26, and the safeguards aspects reported in accordance with 10 CFR 73.71. When a telephone report is required by both rules, only one telephone call is needed to the Operations Center. In that case, a written report of the safeguards aspects must also be submitted within 30 days, as required by 10 CFR 73.71.

4 Page 9 of 9

SJHARED 04/28/03 8:10:36 FNP-0-EIP-8.0 FIGURE 1 FARLEY NUCLEAR PLANT EVENT NOTIFICATION FORM A.

EVENT DATE YY MM DD

/

/

B.

PERSON MAKING NOTIFICATION:

EOSHIFT SUPERINTENDENT EJOTHER C.

EVENT CLASSIFICATION (check appropriate block and list EIP paragraph #

[ ]I0 CFR 50.72 NON-EMERGENCY NOTIFICATION La 10 CFR20 RADIOACTIVE MATERIALS L10 CFR 50.9 (B) SIGNIFICANT EVENT, CONDITION OR INFORMATION

[1110 CFR 73, APP. G REPORTABLE SAFEGUARDS EVENT 010 CFR 26.73 FITNESS FOR DUTY EVENT L10 CFR 72 SPECIAL NUCLEAR MATERIAL CONTROL

]MISCELLANEOUS NOTIFICATIONS D.

Event Date and Time Discovery Date and Time Report Time Requirement

[] one hour

] four hour eight hour LI 24hour 0 48 hour5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> El Other_

Date and Time Report required (event date and time+report time requirement)

E.

Complete appropriate information on the NRC form 361 portion of this figure (last page of this figure) prior to contacting the NRC Operations center. Obtain the Event Notification Number (EN #) from the NRCOC and put that number at the indicated location at the top of the next page. The last page of the form may be faxed to the NRC if they desire.

F.

AGENCIES NOTIFIED

[OALABAMA RADIATION CONTROL

[]ALABAMA EMA EIHOUSTON COUNTY EMA OGEORGIA EMA

[]EARLY COUNTY EMA

[NRC OPERATIONS CENTER

]NRC RESIDENT

]EMERGENCY DIRECTOR ORECOVERY MANAGER OOPERATIONS MANAGER

[]EMERGENCY SUPPORT MANAGER CIOTHER:

PERSON NOTIFIED / TIME

/

/

/

/

/

/

/

I

/

/

/

/

G.

HAS A PRESS RELEASE BEEN MADE OR PLANNED? EIYES [ONO Version 101 Page of 2

LJHARLED, 04/28/03 8:10:36 FNP-0-EIP-8.0 FIGURE 1

-iIMILAR to NRC FORM 361 U.S. NUCLEAR REGULATORY COMMISSION OPERATIONS CENTER REACTOR PLANT EVENT NOTIFICATION WORKSHEET EN #

NRC OPERATION TELEPHONE NUMBER: PRIMARY -- 301-816-5100, BACKUPS - jlstl 301-951-0550 f2ndl 301-415-0550 and [3rdl 301-415-0553 NOTIFICATION TIME FACILITY OR ORGANIZATION UNIT NAME OF CALLER CALL BACK # ENS 700-221-0807 FARLEY NUCLEAR PLANT Comercial #

334.899-5156 EVENT TIME & ZONE EVENT DATE POWERIMODE BEFORE POWERlMODE AFTER EVENT CLASSIFICATIONS 1-Hr. Non-Emergency 10 CFR 50.72(bXl)

(v)(A)

Safe BID Capability AINA GENERAL EMERGENCY GEN/AAEC I

TS Deviabon ADEV (v)(B)

RHR Capability AINB SITE AREA EMERIGENCY SIT/AAEC 4-Hr. Non-Emergency 10 CFR 50.72(bX2)

(v)(C)

Control of Rad Release AINC ALERT ALEIAAEC (i)

TS Required SiD ASHU (v)(D)

Accident Mitigatio AIND UNUSUAL EVENT UNUIMEC (iv)(A)

ECCS Discharge to RCS ACCS (xii)

OffsJte Medical AMED 50.72 NON-EMERGENCY (see next columns)

(iv)(B)

RPS Actuation (scram)

ARPS (xdii)

Loss Comm/AsmtResp ACOM PHYSICALSECURITY (73.71)

DDDD (x)

Offsite Notificabon APRE

_ 60-Day Optional 10 CFR 50.73(aXl)

MATERIAL/EXPOSURE B?7? 8-r. Non-Emergency 10 CFR 50.72(b)(3)

Invalid Specified System Actuabon AINV FITNESS FOR DUTY HFIT (iI)(A)

Degraded Condition ADEG Other Unspecified Requirement (Identify)

OTHER UNSPECIFIED REOMT (see last column)

(ii)(B)

Unanalyzed Condition AUNA I

NONR INFORMATION ONLY NINF Specified System Actuation AESF I

NONR DESCRIPTION Include: Systems affected, actuabtons and their inibating signals. causes, effect of event on plant, actions taken or planned, etc. (Continue on back)

NOTIFICATIONS YES NO WILL BE ANYTHING UNUSUAL OR E YES (Explain above)

[

NO NRC RESIDENT

____NOT UNDERSTOOD?__________

STATE(s)

____DID ALL SYSTEMS LOCAL FUNCTION AS REQUIRED?

YES Ol NO (Explain above)

'THER GOV AGENCIES MODE OF OPERATION ESTIMATED ADDITIONAL INFO QhLBACK AEDIAPRESS RELEASE UNTIL CORRECTED:

RESTART DATE:

E YES O NO Version 101 Page 2 of 2