Another Phone Discussion Re. Check Valve Amendment
ML020250216
Person / Time
Site: Nine Mile Point 
(NPF-069)
Issue date: 01/23/2002
From: Tam P
NRC/NRR/DLPM/LPD1
To: Mackaman C
Constellation Nuclear
References
TAC MB3545
Download: ML020250216 (2)


Text

From:

Peter Tam To:

INTernet:leonardm@nimo.com; internet:mackamanc@nimo.com; internet:wolniakd@nimo.com; John Lehning Date:

1/23/02 10:03AM

Subject:

Another phone discussion re. check valve amendment (TAC MB3545)

Clyde:

We have two questions that we would like to discuss in a telecon with you. This e-mail does not formally request additional information, and does not convey a formal staff position. Thanks.

1. What indications are specified in procedure for operators to determine whether the motor-operated feedwater isolation valve should be closed? Is the outer feedwater check valve position indication currently used for this purpose? If so, what procedural changes would be made?
2. Please confirm or correct the staff's interpretation of the discussion of the IST testing of the outer feedwater check valves: The staff reviewer has interpreted that the normal cessation of feedwater flow during the shutdown progression is currently and is also proposed to be credited with the IST reverse-flow full-stroke valve disc exercise, and that verification of valve closure after this exercise, which is currently through the disc-position indication, is proposed to be through the Type C LLRT, which is normally performed at each refueling outage. Also, is the proposed IST method for the outer feedwater check valves analolgous to the current IST method for the inner feedwater check valves?

Peter S. Tam, Senior Project Manager Project Directorate I-1 Division of Licensing Project Management Office of Nuclear Reactor Regulation e-mail: pst@nrc.gov Tel.: 301-415-1451 Mail Envelope Properties (3C4ED0BC.501 : 10 : 20510)

Subject:

Another phone discussion re. check valve amendment (TAC MB3545)

Creation Date:

1/23/02 10:03AM From:

Peter Tam Created By:

PST@nrc.gov Recipients Action Date & Time nimo.com Transferred 01/23/02 10:03AM leonardm (INTernet:leonardm@nimo.com) mackamanc (internet:mackamanc@nimo.com) wolniakd (internet:wolniakd@nimo.com)

nrc.gov owf2_po.OWFN_DO Delivered 01/23/02 10:03AM JXL4 (John Lehning)

Opened 01/23/02 10:03AM Post Office Delivered Route nimo.com INTernet owf2_po.OWFN_DO 01/23/02 10:03AM nrc.gov Files Size Date & Time MESSAGE 2347 01/23/02 10:03AM Options Auto Delete:

No Expiration Date:

None Notify Recipients:

Yes Priority:

Standard Reply Requested:

No Return Notification:

None Concealed

Subject:

No Security:

Standard To Be Delivered:

Immediate Status Tracking:

Delivered & Opened