Section 2 300-33 ft. Lapse Rate Wind Distributions 4/00 - 6100

ARTIFICIAL ISLAND 04/00-06/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE:

LE -1.9 DEG C/100M CLASS A WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0

0. 0 0.0
0. 0
0. 0 0.0 0.0
0. 0 0.0 0.0 0.0 0.0
0. 0
0. 0
0. 0 0

0 0

1 0

0 0

0 3

0 1

0 0

1 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 4

1 0

0 0

0 3

6 4

1 0

2 5

2 5

0 0.2 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.2 0.0 0.0 0.1 0.2

0. 1 0.2 0.0 4

0 0

1 0

0 2

4 0

0 0

0 3

4 5

10 0.2 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.0 0.0 0.0 0.0 0.1 0.2 0.2 0.5 1

0 0

0 0

0 0

0 0

0 0

0 0

0 0

1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 9

1 0

2 0

0 5

10 7

1 1

2 8

7 10 11 0.4 0.0 0.0 0.1

0. 0 0.0 0.2 0.5 0.3 0.0 0.0
0. 1 0.4 0.3 0.5 0.5 0

0.0 0

0.0 6

0.3 33 1.6 33 1.6 2

0.1 0

0.0 74 3.5 MEAN WIND SPEED:

12.4 MISSING:

0

ARTIFICIAL ISLAND 04/00-06/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE: -1.8 TO -1.7 DEG C/10OM CLASS B WIND SPEED GROUPS (MPH) 0.0-0. S 0.6-3.5 3.6-7.5

7. 6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0

0. 0 0.0
0. 0
0. 0 0.0
0. 0
0. 0 0.0
0. 0 0.0
0. 0
0. 0 0.0
0. 0 0.0 I

0 1

0 0

0 3

2 1

2 2

1 2

1 1

0 0.0 0.0 0.0 0.0 0.0 0.0

0. 1
0. 1 0.0
0. 1
0. 1 0.0 0.1 0.0 0.0 0.0 10 0

5 1

3 2

1 5

0 1

2 2

1 5

5 5

0.5 0.0 0.2 0.0

0. 1
0. 1 0.0 0.2 0.0 0.0
0. 1
0. 1 0.0 0.2 0.2 0.2 4

0 1

2 0

0 2

2 0

0 0

0 2

3 6

3 0.2 0.0 0.0 0.1 0.0 0.0 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.3 0.1 0

0 0

0 0

0 0

0 0

0 0

0 0

1 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

1 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 15 0

7 3

32 6

91 3

4 3

5 11 12 8

0.7 0.0 0.3

0. 1
0. 1
0. 1 0.3 0.4
0. 0 0.1 0.2
0. 1 0.2 0.5 0.6 0.4 0

0.0 0

0.0 17 0.8 48 2.3 25 1.2 1

  • 0.0 1

0.0 92 4.4 MEAN WIND SPEED:

11.0 MISSING:

1

ARTIFICIAL ISLAND 04/00-06/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE: -1.6 TO -1.5 DEG C/1OOM CLASS C WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5

18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0

0. 0
0. 0 0.0 0.0 0.0 0.0 0.0
0. 0
0. 0 0.0
0. 0 0.0 0.0 0.0 0.0 2

0 2

4 1

0 2

2 2

2 3

2 2

1 1

0

0. 1 0.0
0. 1 0.2 0.0 0.0
0. 1
0. 1
0. 1
0. 1
0. 1
0. 1 0.1 0.0 0.0 0.0 3

1 3

5 4

0 1

2 4

4 2

7 8

4 6

9 0.1

0. 0
0. 1 0.2 0.2
0. 0
0. 0
0. 1 0.2 0.2
0. 1 0.3 0.4 0.2 0.3 0.4 3

1 1

1 0

0 3

5 0

0 0

0 4

4 2

5 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.0 0.0 0.0 0.0 0.2 0.2 0.1 0.2 0

0 0

0 0

0 0

0 0

0 0

0 0

2 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0

0 0

.0 0

0 0

0 0

0 0

0 0

1 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 8

2 6

10 5

0 6

9 6

6 5

9 14 12 9

14 0.4

0. 1 0.3 0.5 0.2
0. 0 0.3 0.4 0.3 0.3 0.2 0.4 0.7 0.6 0.4 0.7 0

0.0 0

0.0 26 1.2 63 3.0 29 1.4 2

0.1 1

0.0 121 5.7 MEAN WIND SPEED:

10.3 MISSING:

5

ARTIFICIAL ISLAND 04/00-06/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T:

(300-33FT)

LAPSE RATE: -1.4 TO -0.5 DEG C/1OOM CLASS D WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 3

2 2

2 0

3 0

2 1

0 2

1 0

1 2

3

0. 1
0. 1
0. 1
0. 1
0. 0
0. 1
0. 0
0. 1
0. 0
0. 0
0. 1 0.0
0. 0 0.0
0. 1
0. 1 7

1 5 36 43 8

15 7

18 23 13 12 9

7 8

6 10 0.3 0.7 1.7 2.0 0.4 0.7 0.3 0.9 1.1 0.6 0.6 0.4 0.3 0.4 0.3 0.5 14 13 26 40 15 15 15 31 21 10 22 29 20 15 35 23 0.7 0.6 1.2 1.9 0.7 0.7 0.7 1.5

1. 0 0.5 1.0 1.4 0.9 0.7 1.7
1. 1 4

10 13 1 8 1

0 20 36 14 1 1 7

4 6

15 1 6 1 4 0.2 0.5 0.6 0.9 0.0 0.0 0.9 1.7 0.7 0.5 0.3 0.2 0.3 0.7 0.8 0.7 0

0 2

0 0

0 9

1 0

0 1

0 0

5 2

0 0.0

0. 0 0.1 0.0 0.0
0. 0 0.4 0.0
0. 0 0.0 0.0 0.0 0.0 0.2 0.1 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

1 1

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 28 40 79 103 24 33 51 88 59 34 44 43 33 45 62 50 1.3 1.9 3.7 4.9

1. 1 1.6 2.4 4.2 2.8 1.6 2.1 2.0 1.6 2.1 2.9
2. 4 816 38.6 0

0.0 24 1.1 237 11.2 344 16.3 189 8.9 20 0.9 2

0.1 MEAN WIND SPEED:

9.9 MISSING

43

ARTIFICIAL ISLAND 04/00-06/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE: -0.4 TO 1.5 DEG C/1OOM CLASS E WIND SPEED GROUPS (MPH) 0.0-0.5

0. 6-3. 5 3.6-7.5 7.6-12.5 12.6-18.5 18. 6-24. 5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT 0

0.0 SUM PERCENT 0

0.0 N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1

3 8

4 9

5 2

0 6

4 7

0 0

1 2

1 0.0

0. 1 0.4 0.2 0.4 0.2
0. 1 0.0 0.3 0.2 0.3
0. 0
0. 0 0.0
0. 1 0.0 19 20 23 36 23 15 15 14 15 24 34 20 15 14 27 25 0.9 0.9 1.1 1.7 1.1 0.7 0.7 0.7 0.7 1.1 1.6 0.9 0.7 0.7 1.3 1.2 4

2 5

1 0 10 6

20 17 21 48 34 24 9

13 18 10 0.2

0. 1 0.2 0.5
0. 5 0.3 0.9 0.8
1. 0 2.3 1.6
1. 1 0.4 0.6 0.9 0.5 0

0 0

0 0

0 20 1 0 5

9 8

2 1

2 1

4 0.0 0.0 0.0 0.0 0.0 0.0 0.9 0.5 0.2 0.4 0.4 0.1 0.0 0.1 0.0 0.2 0

0 0

0 0

3 0

3 14 0

0 0

0 1

0

0. 0
0. 0 0.0 0.0 0.0
0. 1
0. 0
0. 1 0.7 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

1 1

0 0

0 0

0 0

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 24 25 36 50 42 26 60 41 51 100 83 46

.25 30 49 40

1. 1
1. 2
1. 7 2.4 2.0 1.2 2.8 1.9 2.4 4.7 3.9 2.2 1.2 1.4 2.3 1.9 0

0.0 53 2.5 339 16.1 251 11.9 62 2.9 21 1.0 2

0.1 728 34.5 MEAN WIND SPEED:

8.1 MISSING

11

ARTIFICIAL ISLAND 04/00-06/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T:

(300-33FT)

LAPSE RATE:

1.6 TO 4.0 DEG C/1OOM CLASS F WIND SPEED GROUPS (MPH) 0.0-0.5 DIRECTION SUM PERCENT 0.6-3.5 SUM PERCENT 3.6-7.5 SUM PERCENT 7.6-12.5 SUM PERCENT 12.6-18.5 SUM PERCENT 18.6-24.5 SUM PERCENT GE 24.6 SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1

0 7

4 0

2 5

4 1

1 0

2 1

0 1

2

0. 0 0.0 0.3 0.2
0. 0
0. 1 0.2 0.2
0. 0
0. 0
  • 0. 0
0. 1 0.0
0. 0 0.0
0. 1 8

6 4

7 5

1 0 5

1 1 4

1 3 1 8 22 9

1 0 6

9 0.4 0.3 0.2 0.3 0.2 0.5 0.2 0.5 0.2 0.6 0.9 1.0 0.4 0.5 0.3 0.4 0

0 1

0 0 -

1 8

5 1 1 9

8 5

4 3

2 0.0 0.0 0.0

0. 0
0. 0 0.0 0.4 0.2 0.2
0. 5 0.4 0.4 0.2 0.2
0. 1
0. 1 0

0 0

0 0

0 4

4 2

1 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.2

0. 1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0
0. 0 0.0
0. 0
0. o
0. 0 0.0 0.0 0.0 0.0 0

0 0

0 0

.0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 9

6 12 1 15 13 22 24 12 26 27 32 15 14 10 13 0.4 0.3 0.6 0.5 0.2 0.6 1.0

1. 1 0.6 1.2 1.3 1.5 0.7 0.7 0.5 0.6 0

0.0 31 1.5 147 7.0 62 2.9 11 0.5 0

0.0 0

0.0 251 11.9 MEAN WIND SPEED:

6.5 MISSING

3

ARTIFICIAL ISLAND 04/00-06/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE:

GT 4.0 DEG C/1OOM CLASS G WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5

18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 1

0 0

0 0

2 0

0 0

0 0

0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0
0. 1 0.0
0. 0
0. 0
0. 0 0.0
0. 0 0

0 1

2 0

0 4

7 1

1 0

1 0

0 1

0 0.0 0.0 0.0

0. 1 0.0 0.0 0.2 0.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 7

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0

0. 0 0.0 0.3 0.0
0. 0 0.0 0.0 0.0
0. 0 0.0
0. 0 0.0 0

0 0

0 0

0 1

1 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0

0. 0
0. 0 0.0 0.0
0. 0 0.0 0.0 0.0 0.0
0. 0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0.0 0

0.0 1

0.0 2

0.1 1

0.0 0

0.0 12 0.6 8

0.4 1

0.0 3

0.1 0

0.0 1

0.0 0

0.0 0

0.0 1

0.0 0

0.0 30 1.4 0

0.0 3

0.1 18 0.9 7

0.3 2

0.1 0

0.0 0

0.0 MEAN WIND SPEED:

6.7 MISSING

0

ARTIFICIAL ISLAND 04/00-06/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

ALL STABILITY CLASSES WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5 12.6-18.5
18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 5

5 17 10 10 10 7

6 8

7 9

3 1

2 5

6 0.2 0.2 0.8 0.5 0.5 0.5 0.3 0.3 0.4 0.3 0.4

0. 1
0. 0
0. 1 0.2 0.3 37 41 67 93 37 40 36 54 49 55 70 55 35 35 42 44 1.8 1.9 3.2 4.4 1.8 1.9 1.7 2.6 2.3 2.6 3.3 2.6 1.7 1.7 2.0 2.1 35 17 40 56 32 24 55 66 55 75 69 72 48 43 72 49 1.7 0.8 1.9 2.7 1.5
1. 1 2.6 3.1 2.6 3.6 3.3 3.4 2.3 2.0 3.4 2.3 15 11 15 22 1

0 52 62 21 21 15 6

16 28 30 36 0.7 0.5 0.7 1.0 0.0 0.0 2.5 2.9 1.0 1.0 0.7 0.3 0.8 1.3 1.4 1.7 1

0 2

0 0

0 1 2 1

3 1 4 1

0 0

8 3

1 0.0 0.0 0.1 0.0 0.0 0.0 0.6 0.0 0.1 0.7 0.0 0.0 0.0 0.4 0.1 0.0 0

0 0

0 0

0 0

0 1

1 0

0 0

3 1

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 93 74 141 181 80 74 162 189 137 173 164 136 100 119 153 136 4.4 3.5 6.7 8.6 3.8 3.5 7.7 8.9 6.5 8.2 7.8 6.4 4.7 5.6 7.2 6.4 0

0.0 111 5.3 790 37.4 808 38.3 351 16.6 46 2.2 6

0.3 2112 100.0 MISSING HOURS:

72 MEAN WIND SPEED:

9.0

ARTIFICIAL ISLAND 04/00-06/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

DIRECTION VS SPEED ONLY WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5

3. 6-7.5
7. 6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 5

5 17 10 1 0 1 0 7

6 8

7 9

3 1

2 5

6 0.2 0.2 0.8 0.5 0.5 0.5 0.3 0.3 0.4 0.3 0.4

0. 1
0. 0
0. 1 0.2 0.3 37 41 67 93 37 40 36 54 50 55 70 55 35 35 42 44 1.7 1.9 3.2 4.4 1.7 1.9 1.7 2.5 2.4 2.6 3.3 2.6 1.7 1.7 2.0 2.1 35 137 4 0 5°6 32 24 5 5 66 5 5 7 5 69 72 48 4 5 72 49 1.7 0.8 1.9 2.6 1.5
1. 1 2.6 3.1 2.6 3.5 3.3 3.4 2.3 2.1 3.4 2.3 15 11 15 22 1

0 52 63 21 21 15 6

16 28 30 36 0.7 0.5 0.7 1.0 0.0 0.0 2.5 3.0 1.0 1.0 0.7 0.3 0.8 1.3 1.4 1.7 1

0 2

0 0

0 12 1

3 14 1

0 0

10 3

1

0. 0 0.0 0.1 0.0 0.0 0.0 0.6 0.0
0. 1 0.7 0.0 0.0 0.0 0.5 0.1 0.0 0

0 0

0 0

0 0

0 1

1 0

0 0

5 1

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.0 0.0 93 74 141 181 80 74 162 190 138 173 164 136 100 125 153 136 4.4 3.5 6.7 8.5 3.8 3.5 7.6 9.0 6.5 8.2 7.7 6.4 4.7 5.9 7.2 6.4 0

0.0 111 5.2 791 37.3 810 38.2 352 16.6 48 2.3 8

0.4 2120 100.0 MISSING HOURS:

64 MEAN WIND SPEED:

9.0

ARTIFICIAL ISLAND 04/00-06/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE:

LE -1.9 DEG C/1OOM CLASS A WIND SPEED GROUPS (MPH)

0. 0 -0. 5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

0. 0
0. 0 0.0
0. 0
0. 0 0.0
0. 0
0. 0
0. 0 0.0 0.0
0. 0 0.0
0. 0
0. 0
0. 0 0

0 0

0 0

0 0

0 1

1 0

0 0

1 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 2

1 1

0 0

0 4

3 5

1 0

0 4

1 3

0

0. 1
0. 0 0.0
0. 0
0. 0
0. 0 0.2
0. 1 0.2 0.0 0.0
0. 0 0.2 0.0
0. 1 0.0 3

1 0

0 0

0 1

6 0

0 0

0 2

1 7

2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.3 0.0 0.0 0.0 0.0 0.1 0.0 0.3 0.1 2

0 0

1 0

0 1

1 0

0 0

0 3

4 1

1 0

0. 1 0.0
0. 0
0. 0 0.0
0. 0 0.0
0. 0
0. 0 0.0
0. 0 0.0 0.1 0.2 0.0 0.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 7

0.3 2

0.1 1

0.0 1

0.0 0

0.0 0

0.0 6

0.3 10 0.5 6

0.3 2

0.1 0

0.0 0

0.0 9

0.4 7

0.3 11 0.5 12 0.6 74 3.4 0

0.0 0

0.0 3

0.1 25 1.1 23 1.1 23 1.1 0

0.0 MEAN WIND SPEED:

15.0 MISSING:

0

ARTIFICIAL ISLAND 04/00-06/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE: -1.8 TO -1.7 DEG C/1OOM CLASS B WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5
12. 6-18.5
18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0

0. 0
0. 0
0. 0 0.0 0.0 0.0 0.0
0. 0
0. 0
0. 0
0. 0
0. 0 0.0 0.0 0.0 1

0 0

0 0

0 2

3 1

2 0

2 0

1 1

0 0.0 0.0 0.0 0.0 0.0 0.0

0. 1
0. 1 0.0
0. 1 0.0 0.1 0.0 0.0 0.0 0.0 6

5 3

1 2

3 2

1 1

1 0

1 2

3 3

2 0.3 0.2

0. 1
0. 0
0. 1 0.1
0. 1 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 1

5 2

2 0

0 2

4 0

0 3

2 1

2 3

2 0.0 0.2

0. 1 0.1 0.0 0.0 0.1 0.2 0.0 0.0 0.1 0.1 0.0 0.1 0.1 0.1 1

1 0

1 0

0 2

0 0

0 0

0 0

3 4

1 0.0 0.0 0.0 0.0

0. 0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

2 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 9

11 5

4 2

3 8

8 2

3 3

5 3

11 11 5

0.4 0.5 0.2 0.2

0. 1
0. 1 0.4 0.4 0.1
0. 1 0.1 0.2
0. 1 0.5 0.5 0.2 0

0.0 0

0.0 13 0.6 36 1.7 29 1.3 13 0.6 2

0.1 93 4.3 MEAN WIND SPEED:

13.3 MISSING:

0

ARTIFICIAL ISLAND 04/00-06/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T:

(300-33FT)

LAPSE RATE: -1.6 TO -1.5 DEG C/1OOM CLASS C WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5

18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

o 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

0. 0 0.0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0 1

2 3

2 1

0 4

2 2

2 1

3 0

1 2

0 0.0

0. 1
0. 1
0. 1 0.0 0.0 0.2
0. I
0. 1
0. 1 0.0
0. 1 0.0 0.0
0. 1 0.0 4

3 3

5 3

0 2

2 1

5 2

4 5

0 2

5 0.2

0. 1
0. 1 0.2
0. 1 0.0
0. 1
0. 1
0. 0 0.2
0. 1 0.2 0.2
0. 0
0. 1 0.2 2

3 1

2 0

0 0

4 3

5 2

2 2

1 3

3 0.1 0.1 0.0 0.1 0.0 0.0 0.0 0.2 0.1 0.2 0.1 0.1 0.1 0.0 0.1 0.1 0

2 0

1 0

0 2

3 0

0 0

0 1

3 1

3 0.0

0. 1 0.0
0. 0 0.0 0.0
0. 1
0. 1 0.0 0.0 0.0 0.0 0.0
0. 1 0.0 0.1 0

0 0

0 0

0 1

0 0

0 0

0 0

3 0

0 0.0 0.0.

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 7

10 7

10 4

0 9

1 1 6

1 2 5

9 8

8 8

1 1 0.3 0.5 0.3 0.5 0.2

0. O 0.4 0.5 0.3 0.6 0.2 0.4 0.4 0.4 0.4 0.5 0

0.0 0

0.0 26 1.2 46 2.1 33 1.5 16 0.7 4

0.2 125 5.7 MEAN WIND SPEED:

MISSING:

12.5 1

ARTIFICIAL ISLAND 04/00-06/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE: -1.4 TO -0.5 DEG C/1OOM CLASS D WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5

18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 2

0 1

3 1

0 1

1 1

0 4

0 1

0 0

1

0. 1 0.0 0.0
0. 1 0.0
0. 0
0. 0 0.0 0.0 0.0 0.2 0.0 0.0 0.0 0.0 0.0 5

14 30 30 12 7

9 21 15 3

3 6

1 1

3 4

0.2 0.6 1.4 1.4 0.6 0.3 0.4 1.0 0.7 0.1

0. 1 0.3 0.0 0.0
0. 1 0.2 16 17 36 38 17 12 13 18 17 18 1 5 6

12 10 18 14 0.7 0.8 1.7 1.7 0.8 0.6 0.6 0.8 0.8 0.8 0.7 0.3 0.6 0.5 0.8 0.6 14 27 17 27 4

6 17 40 19 25 13 11 8

11 19 8

0.6 1.2 0.8 1.2 0.2 0.3 0.8 1.8 0.9 1.1 0.6 0.5 0.4 0.5 0.9 0.4 1

10 16 7

0 2

19 12 4

9 4

0 2

9 10 3

0.0 0.5 0.7 0.3 0.0

0. 1 0.9 0.6 0.2 0.4 0.2 0.0 0.1 0.4 0.5 0.1 0

0 4

0 0

0 12 1

0 0

1 0

0 7

2 1

0.0 0.0 0.2 0.0 0.0 0.0 0.6 0.0 0.0 0.0 0.0 0.0 0.0 0.3 0.1 0.0 38 68 104 105 34 27 71 93 56 55 40 23 2 4 38 52 31 1.7

3. 1 4.8 4.8 1.6
1. 2
3. 3 4.3 2.6 2.5 1.8
1. 1
1. 1 1.7 2.4 1.4 0

0.0 16 0.7 164 7.5 277 12.7 266 12.2 108 5.0 28 1.3 859 39.5 MEAN WIND SPEED:

12.8 MISSING:

0

ARTIFICIAL ISLAND 04/00-06/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE: -0.4 TO 1.5 DEG C/1OOM CLASS E WIND SPEED GROUPS (MPH) 0.0-0.5 DIRECTION SUM PERCENT 0.6-3.5 SUM PERCENT 3.6-7.5 SUM PERCENT 7.6-12.5 SUM PERCENT 12.6-18.5 SUM PERCENT

18. 6-24.5 SUM PERCENT GE 24.6 SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1

1 1

3 0

1 2

2 2

1 0

1 0

0 3

0

0. 0 0.0 0.0
0. 1
0. 0
0. 0
0. 1
0. 1
0. 1
0. 0
0. 0
0. 0
0. 0
0. 0
0. 1
0. 0 6

10 1 0 15 13 10 8

10 18 15 13 4

4 15 6

4 0.3 0.5 0.5 0.7 0.6 0.5 0.4 0.5 0.8 0.7 0.6 0.2 0.2 0.7 0.3 0.2 14 26 15 29 22 14 13 8

32 36 11 17 10 9

15 9

0.6 1.2 0.7 1.3 1.0 0.6 0.6 0.4 1.5 1.7

0. 5 0.8 0.5 0.4 0.7 0.4 4

S 4

10 0

5 19 10 29 4 8 18 8

2 10 1 4 8

0.2 0.2 0.2 0.5 0.0 0.2 0.9 0.5 1.3 2.2 0.8 0.4 0.1 0.5 0.6 0.4 0

2 0

0 0

1 1 8 1 1 3

8 6

2 1

1 2

3 0.0 0.1 0.0 0.0 0.0 0.0 0.8 0.5 0.1 0.4 0.3 0.1 0.0 0.0 0.1

0. 1 0

0 0

0 0

0 5

2 3

17 0

0 0

0 1

0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.1 0.1 0.8 0.0 0.0 0.0 0.0 0.0 0.0 25 44 30 57 35 31 65 43 87 125 48 32 17 35 41 24 1.1 2.0 1.4 2.6 1.6 1.4 3.0 2.0 4.0 5.7 2.2 1.5 0.8 1.6 1.9

1. 1 0

0.0 18 0.8 161 7.4 280 12.9 194 8.9 58 2.7 28 1.3 739 34.0 MEAN WIND SPEED:

11.9 MISSING:

0

ARTIFICIAL ISLAND 04/00-06/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE:

1.6 TO 4.0 DEG C/1OOM CLASS F WIND SPEED GROUPS (MPH) 0.0-0. 5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE EN E E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 1
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0 3

2 2

2 7

6 2

7 2

1 3

6 1

2 0

0

0. 1
0. 1
0. 1
0. 1 0.3 0.3
0. 1 0.3
0. 1 0.0
0. 1 0.3 0.0
0. 1 0.0 0.0 3

6 1 0 5

6 4

4 7

3 12 9

14 11 10 4

8

0. 1 0.3
0. 5 0.2 0.3 0.2 0.2 0.3
0. 1 0.6 0.4 0.6 0.5 0.5 0.2 0.4 0

0 0-0 0

0 4

6 16 14 13 9

4 0

4 3

0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.3 0.7 0.6 0.6 0.4 0.2 0.0 0.2 0.1 0

0 0

0 0

0 3

4 1

1 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0

0. 1 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

.0 0

0 1

1 0

0 0

0 0

0 0

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 6

8 12 7

13 10 14 27 24 28 26 30 17 13 8

11 0.3 0.4 0.6 0.3 0.6 0.5 0.6 1.2

1. 1 1.3 1.2 1.4 0.8 0.6 0.4 0.5 0

0.0 8

0.4 46 2.1 116 5.3 73 3.4 9

0.4 2

0.1 254 11.7 MEAN WIND SPEED:

10.9 MISSING:

0

ARTIFICIAL ISLAND 04/00-06/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE:

GT 4.0 DEG C/1OOM CLASS G WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

1 0

0 0

0 0

0 0

0

0. 0 0.0
0. 0
0. 0 0.0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0 0.0 0.0 0

0 0

0 0

2 0

0 0

0 2

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0

0. 1 0.0 0.0 0.0 0.0 0.0 0

0 0

0 2

0 3

1 0

4 2

0 1

.1 0

0 0.0

0. 0
0. 0
0. 0
0. 1
0. 0
0. 1
0. 0
0. 0 0.2
0. 1 0.0
0. 0 0.0 0.0
0. 0 0

0 0

1 0

0 3

3 0

1 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 2

0 1

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0

0. 0
0. 0
0. 1
0. 0 0.0 0.0 0.0 0.0 0.0 0.0
0. 0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

1 2

2 8

5 1

5 4

0 1

1 0

0 0.0

0. 0
0. 0 0.0
0. 1
0. 1 0.4 0.2
0. 0 0.2 0.2 0.0
0. 0 0.0 0.0 0.0 0

0.0 1

0.0 4

0.2 14 0.6 8

0.4 3

0.1 0

0.0 30 1.4 MEAN WIND SPEED:

11.8 MISSING:

0

ARTIFICIAL ISLAND 04/00-06/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

ALL STABILITY CLASSES WIND SPEED GROUPS (MPH)

0. 0-0. 5 0.6-3.5 3.6-7.5
7. 6-12.5 12.6-18.5
18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 3

1 2

6 1

1 4

6 4

1 5

2 2

1 3

1 0.1

0. 0
0. 1 0.3 0.0 0.0 0.2 0.3 0.2 0.0 0.2
0. 1
0. 1 0.0
0. 1
0. 0 16 28 45 49 33 25 25 43 39 24 22 21 6

21 12 8

0.7 1.3 2.1 2.3 1.5 1.1

1. 1 2.0 1.8 1.1 1.0 1.0 0.3 1.0 0.6 0.4 45 58 68 78 52 33 41 40 59 77 39 42 45 34 45 38 2.1 2.7 3.1 3.6 2.4 1.5 1.9 1.8 2.7 3.5 1.8 1.9 2.1 1.6 2.1 1.7 24 41 24 42 4

11 46 73 67 93 49 32 19 25 50 26 1.1 1.9 1.1 1.9 0.2 0.5 2.1 3.4 3.1 4.3 2.3 1.5 0.9 1.1 2.3 1.2 4

15 16 10 0

3 47 31 9

18 10 2

7 20 18 20 0.2 0.7 0.7 0.5 0.0 0.1

2. 2 1.4 0.4 0.8 0.5 0.1 0.3 0.9 0.8 0.9 0

0 4

0 0

0 18 4

4 17 1

0 0

12 3

1 0.0 0.0*

0.2 0.0 0.0 0.0 0.8 0.2 0.2 0.8 0.0 0.0 0.0 0.6 0.1 0.0 92 143 159 185 90 73 181 197 182 230 126 99 79 113 131 94 4.2 6.6 7.3 8.5 4.1 3.4 8.3 9.1 8.4 10.6 5.8 4.6 3.6 5.2 6.0 4.3 0

0.0 43 2.0 417 19.2 794 36.5 626 28.8 230 10.6 64 2.9 2174 100.0 MISSING HOURS:

10 MEAN WIND SPEED:

12.3

ARTIFICIAL ISLAND 04/00-06/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

DIRECTION VS SPEED ONLY WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 0.0
0. 0 0.0 0.0 0.0 0.0 3

1 2

6 1

1 4

6 4

1 5

2 2

1 3

1

0. 1 0.0
0. 1 0.3
0. 0
0. 0 0.2 0.3 0.2
0. 0
  • 0.2
0. 1
0. 1 0.0
0. 1 0.0 16 28 45 49 33 25 25 43 39 24 22 21 6

21 12 8

0.7 1.3 2.1 2.2 1.5 1.1

1. 1 2.0 1.8 1.1 1.0 1.0 0.3 1.0 0.5 0.4 45 58 68 78 52 33 41 40 60 77 39 42 45 35 45 38 2.1 2.7 3.1 3.6 2.4 1.5 1.9 1.8 2.7 3.5 1.8 1.9 2.1 1.6 2.1 1.7 24 41 24 42 4

11 46 74 67 93 49 32 19 27 50 26 1.1 1.9 1.1 1.9 0.2 0.5 2.1 3.4 3.1 4.3 2.2 1.5 0.9 1.2 2.3 1.2 4

15 16 1 0 0

3 4 7 3 1 9

18 10 2

7 20 18 20 0.2 0.7 0.7 0.5 0.0

0. 1 2.2 1.4 0.4 0.8 0.5 0.1 0.3 0.9 0.8 0.9 0

0 4

0 0

18 4

4 17 1

0 0

1 6 3

1 0.0 0.0 0.2 0.0 0.0 0.0 0.8 0.2 0.2 0.8 0.0 0.0 0.0 0.7 0.1 0.0 92 143 159 185 90 73 181 198 183 230 126 99 79 120 131 94 4.2 6.6 7.3 8.5 4.1 3.3 8.3

9. 1 8.4 10.5 5.8 4.5 3.6 5.5 6.0 4.3 0

0.0 43 2.0 417 19.1 796 36.5 629 28.8 230 10.5

68.

3.1 2183 100.0 MISSING HOURS:

1 MEAN WIND SPEED:

12.4

ARTIFICIAL ISLAND 04/00-06/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T:

(300-33FT)

LAPSE RATE:

LE -1.9 DEG C/100M CLASS A WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0
0. 0 0.0 0.0
0. 0
0. 0 0

0 0

0 0

0 0

1 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 2

0 1

0 0

0 4

5 2

1 1

1 3

0 3

0 0.1 0.0 0.0 0.0 0.0 0.0 0.2 0.2 0.1 0.0 0.0 0.0 0.1 0.0 0.1 0.0 2

0 0

0 0

0 1

6 0

0 0

1 1

0 5

4 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.3 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.2 2

0 0

1 0

0 1

1 0

0 0

0 1

6 0

1 1

0. 1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.3 0.0 0.5 1

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 7

0.3 0

0.0 1

0.0 1

0.0 0

0.0 0

0.0 6

0.3 13 0.6 2

0.1 1

0.0 1

0.0 2

0.1 5

0.2 6

0.3 8

0.4 is 0.7 68 3.3 0

0.0 0

0.0 1

0.0 23 1.1 20 1.0 23 1.1 1

0.0 MEAN WIND SPEED:

15.8 MISSING:

6

ARTIFICIAL ISLAND 04/00-06/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE: -1.8 TO -1.7 DEG C/1OOM CLASS B WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0

0. 0
0. 0
0. 0
0. 0
0. 0 0.0
0. 0
0. 0
0. 0
0. 0 0.0
0. 0
0. 0
0. 0 0.0 0

0 0

0 0

0 0

3 2

0 1

1 1

1 1

1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1

0. 1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 3

1 2

1 2

3 3

0 0

1 1

1 1

3 3

4

0. 1 0.0 0.1
0. 0
0. 1 0.1
0. 1 0.0 0.0 0.0 0.0 0.0
0. 0 0.1
0. 1 0.2 1

4 2

0 0

2 1

4 0

0 1

4 1

2 1

6 0.0 0.2 0.1 0.0 0.0 0.1 0.0 0.2 0.0 0.0 0.0 0.2 0.0 0.1 0.0 0.3 1

0 1

0 0

0 2

0 0

0 0

0 0

3 5

3 0.0 0.0 0.0 0.0 0.0 0.0

0. 1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.1 0

0 0

0 0

0 0

0 0

0 0

0 0

2 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 5

5 5

1 2

5 6

7 2

1 3

6 3

11 10 14 0.2 0.2 0.2 0.0

0. 1 0.2 0.3 0.3
0. 1 0.0 0.1 0.3
0. 1 0.5 0.5 0.7 0

0.0 0

0.0 11 0.5 29 1.4 29 1.4 15 0.7 2

0.1 86 4.2 MEAN WIND SPEED:

14.2 MISSING:

7

ARTIFICIAL ISLAND 04/00-06/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND:

300 FT DELTA T:

(300-33FT)

LAPSE RATE: -1.6 TO -1.5 DEG C/1OOM CLASS C WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18. 5

18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0

0. 0
0. 0 0.0
0. 0
0. 0 0.0 0.0 0.0 0.0 0.0
0. 0 0.0 0.0 0.0
0. 0 0

3 2

1 1

2 3

1 1

3 0

4 0

3 2

0

0. 0 0.1
0. 1 0.0 0.0
0. 1
0. 1 0.0
0. 0 0.1 0.0 0.2 0.0
0. 1
0. 1 0.0 2

1 2

5 2

0 3

0 0

0 3

5 3

0 5

3 0.1 0.0 0.1 0.2

0. 1 0.0
0. 1 0.0 0.0 0.0
0. 1 0.2
0. 1
0. 0 0.2
0. 1 0

2 1

2 0

0 0

4 2

6 3

4 4

2 5

2 0.0 0.1 0.0 0.1 0.0 0.0 0.0 0.2 0.1 0.3 0.1 0.2 0.2 0.1 0.2 0.1 1

1 1

0 0

0 2

2 0

0 0

0 3

2 1

6 0.0 0.0 0.0 0.0 0.0 0.0

0. 1
0. 1 0.0 0.0 0.0 0.0 0.1
0. 1 0.0 0.3 0

0 0

0 0

0 2

0 0

0 0

0 0

4 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.0 0.0 3

7 6

8 3

2 10 7

3 9

6 13 10 11 13 11

0. 1 0.3 0.3 0.4
0. 1 0.1 0.5 0.3
0. 1 0.4 0.3 0.6 0.5 0.5 0.6 0.5 0

0.0 0

0.0 26 1.3 34 1.7 37 1.8 19 0.9 6

0.3 122 5.9 MEAN WIND SPEED:

13.3 MISSING:

4

ARTIFICIAL ISLAND 04/00-06/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T:

(300-33FT)

LAPSE RATE: -1.4 TO -0.5 DEG C/1OOM CLASS D WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1

0 2

0 1

0 2

3 0

1 2

1 1

0 1

1

0. 0
0. 0
0. 1
0. 0
0. 0
0. 0
0. 1
0. 1
0. 0
0. 0
0. 1
0. 0
0. 0
0. 0
0. 0
0. 0 1

5 2 3 1 3 8

4 141 1 9 7

2 4

4 4

5 4

3 0.0 0.2 1.1 0.6 0.4 0.2 0.5 0.9 0.3 0.1 0.2 0.2 0.2 0.2 0.2

0. 1 14 7

31 24 16 13 10 16 14 10 15 15 11 12 11 8

0.7 0.3 1.5 1.2 0.8 0.6 0.5 0.8 0.7 0.5 0.7 0.7 0.5 0.6 0.5 0.4 9

1 4 25 2 3 6

10 24 27 18 13 21 22 13 10 20 14 0.4 0.7 1.2 1.1 0.3 0.5 1.2 1.3 0.9 0.6 1.0 1.1 0.6 0.5

1. 0 0.7 3

14 12 11 0

0 15 10 9

8 7

6 2

15 22 7

0. 1 0.7 0.6 0.5 0.0
0. 0 0.7 0.5 0.4 0.4 0.3 0.3 0.1 0.7
1. 1 0.3 0

0 11 0

0 0

17 3

0 1

1 0

0 9

6 2

0.0 0.0 0.5 0.0 0.0 0.0 0.8 0.1 0.0 0.0 0.0 0.0 0.0 0.4 0.3 0.1 28 40 104 71 31 27 79 78 48 35 50 48 31 51 64 35 1.4

1. 9 5.1 3.4 1.5 1.3 3.8 3.8 2.3 1.7 2.4 2.3 1.5 2.5 3.1 1.7 0

0.0 16 0.8 117 5.7 227 11.0 269 13.1 141 6.8 50 2.4 820 39.8 MEAN WIND SPEED:

MISSING:

14.0 39

ARTIFICIAL ISLAND 04/00-06/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE: -0.4 TO 1.5 DEG C/1OOM CLASS E WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1

0 0

0 2

1 0

0 3

2 0

1 0

1 0

1 0.0 0.0 0.0

0. 0
0. 1
0. 0 0.0
0. 0
0. 1
0. 1 0.0
0. 0 0.0 0.0 0.0 0.0 3

2 4

1 3 6

8 3

S 7

5 3

5 5

2 5

2

0. 1
0. 1 0.2 0.6 0.3 0.4
0. 1 0.2 0.3 0.2 0.1 0.2 0.2 0.1 0.2 0.1 5

14 20 2 6 1 3 8

11 1 1 1 1 15 17 18 1 3 17 19 16 0.2 0.7

1. 0 1.3 0.6 0.4 0.5 0.5
0. 5 0.7 0.8 0.9 0.6 0.8 0.9 0.8 4

6 11 10 3

4 19 6

14 34 58 12 10 12 11 10 0.2 0.3 0.5 0.5 0.1 0.2 0.9 0.3 0.7 1.7 2.8 0.6 0.5 0.6 0.5 0.5 0

0 1

0 0

0 23 6

7 32 14 1

1 3

3 4

0.0 0.0 0.0

0. 0 0.0 0.0
1. 1 0.3 0.3 1.6 0.7
0. 0 0.0 0.1
0. 1 0.2 0

0 0

0 0

.0 8

3 1

23 3

1 0

0 3

0 0.0 0.0 0.0 0.0 0.0 0.0 0.4 0.1 0.0 1.1 0.1 0.0 0.0 0.0 0.1 0.0 13 22 36 49 24 21 64 31 43 111 95 38 29 35 41 33 0.6

1. 1 1.7 2.4 1.2
1. 0 3.1 1.5 2.1 5.4 4.6 1.8 1.4 1.7 2.0 1.6 0

0.0 12 0.6 78 3.8 234 11.4 224 10.9 95 4.6 42 2.0 685 33.3 MEAN WIND SPEED:

13.9 MISSING:

54

ARTIFICIAL ISLAND 04/00-06/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE:

1.6 TO 4.0 DEG C/100M CLASS F WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 SUM PERCENT 3.6-7.5 SUM PERCENT 7.6-12.5 SUM PERCENT 12.6-18.5 SUM PERCENT

18. 6-24.5 SUM PERCENT GE 24.6 SUM PERCENT DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUM PERCENT SUM PERCENT 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0
0. 0 0.0 0.0 0.0 0.0 0.0 I

0 0

0 0

0 0

1 2

0 0

2 0

0 0

1

0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. I
0. 0
0. 0
0. 1
0. 0
0. 0
0. 0
0. 0 0

1 1

1 1

1 2

2 5

1 1

3 0

0 2

0 0.0 0.0 0.0 0.0 0.0 0.0

0. 1
0. 1 0.2 0.0 0.0
0. 1 0.0 0.0
0. 1 0.0 5

1 4

6 6

8 4

3 3

2 1

3 2

6 5

3 0.2

0. 0 0.2 0.3 0.3 0.4 0.2
0. 1
0. 1
0. 1 0.0
0. 1
0. 1 0.3 0.2 0.1 2

4 9

0 0

0 2

2 6

13 17 20 13 12 5

5 0.1 0.2 0.4 0.0 0.0 0.0 0.1 0.1 0.3 0.6 0.8

1. 0 0.6 0.6 0.2 0.2 0

0 0

0 0

0 1

5 4

1 4 10 4

0 1

4 1

0.0 0.0 0.0

0. 0 0.0 0.0
0. 0 0.2 0.2 0.7 0.5 0.2 0.0 0.0 0.2 0.0 0

0 0

0 0

0 0

2 1

1 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 8

6 14 7

7 9

9 1 5 21 3 1 29 32 15 19 16 10 0.4 0.3 0.7 0.3 0.3 0.4 0.4 0.7

1. 0 1.5 1.4 1.6 0.7 0.9 0.8 0.5 0

0.0 7

0.3 21 1.0 62 3.0 110 5.3 44 2.1 4

0.2 248 12.0 MEAN WIND SPEED:

13.9 MISSING:

6

ARTIFICIAL ISLAND 04/00-06/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE:

GT 4.0 DEG C/1OOM CLASS G WIND SPEED GROUPS (MPH)

0. 0-0. 5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18. 6-24. 5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0 0.0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0 0.0 0.0 0

0 0

0 1

1 0

0 1

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

2 1

2 0

3 2

0 1

2 1

0 1

0 0.0

0. 0 0.0
0. 1
0. 0
0. 1 0.0
0. 1
0. 1 0.0 0.0
0. 1
0. 0 0.0
0. 0
0. 0 0

0 0

1 0

0 0

1 1

2 2

2 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

1 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

1 1

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0.0 0

0.0 0

0.0 3

0.1 2

0.1 3

0.1 0

0.0 6

0.3 5

0.2 2

0.1 3

0.1 4

0.2 1

0.0 0

0.0 1

0.0 0

0.0 30 1.5 0

0.0 0

0.0 3

0.1 15 0.7 9

0.4 1

0.0 2

0.1 MEAN WIND SPEED:

12.8 MISSING:

0

ARTIFICIAL ISLAND 04/00-06/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T:

(300-33FT)

ALL STABILITY CLASSES WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 3

0 2

0 3

1 2

4 S

3 2

4 1

I 1

3

0. 1 0.0
0. 1
0. 0
0. 1 0.0
0. 1 0.2
0. 2
0. 1
0. 1 0.2 0.0
0. 0 0.0
0. 1 4

11 30 28 17 16 19 31 23 11 9

17 10 11 14 6

0.2 0.5 1.5 1.4 0.8 0.8 0.9 1.5

1. 1 0.5 0.4 0.8 0.5 0.5 0.7 0.3 31 24 60 64 40 34 35 38 32 29 39 45 34 38 47 34 1.5 1.2 2.9 3.1 1.9 1.7 1.7 1.8 1.6 1.4 1.9 2.2 1.7 1.8 2.3 1.7 18 30 48 36 9

16 47 50 41 68 102 65 42 38 47 41 0.9 1.5 2.3 1.7 0.4 0.8 2.3 2.4 2.0 3.3 5.0 3.2 2.0 1.8 2.3 2.0 7

15 15 12 0

0 44 25 20 5 4 31 11 7

30 35 32 0.3 0.7 0.7 0.6 0.0 0.0 2.1 1.2 1.0 2.6 1.5 0.5 0.3 1.5 1.7 1.6 1

0 11 0

0 0

27 9

3 25 4

1 0

15 9

2 0.0 0.0 0.5 0.0 0.0 0.0 1.3 0.4 0.1 1.2 0.2 0.0 0.0 0.7 0.4 0.1 64 80 166 140 69 67 174 157 124 190 187 143 94 133 153 118 3.1 3.9 8.1 6.8 3.4 3.3 8.5 7.6 6.0 9.2 9.1 6.9 4.6 6.5 7.4 5.7 0

0.0 35 1.7 257 12.5 624 30.3 698 33.9 338 16.4 107 5.2 2059 100.0 MISSING HOURS:

125 MEAN WIND SPEED:

14.0

ARTIFICIAL ISLAND 04/00-06/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND:

300 FT DELTA T:

(300-33FT)

DIRECTION VS SPEED ONLY WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 3

0 2

0 3

1 2

4 5

3 2

4 1

1 1

3

0. 1
0. 0
0. 1
0. 0
0. 1
0. 0
0. 1 0.2 0.2
0. 1
0. 1 0.2
0. 0
0. 0 0.0 0. 1 4

11 30 28 17 16 19 31 23 11 9

17 10 11 14 6

0.2 0.5 1.5 1.4 0.8 0.8 0.9 1.5 1.1 0.5 0.4 0.8 0.5 0.5 0.7 0.3 31 24 60 64 40 34 35 38 33 29 39 45 34 38 47 34 1.5 1.2 2.9 3.1 1.9 1.6 1.7 1.8 1.6 1.4 1.9 2.2 1.6 1.8 2.3 1.6 18 30 48 36 9

16 47 51 41 68 102 65 43 38 47 41 0.9 1.5 2.3 1.7 0.4 0.8 2.3 2.5 2.0 3.3 4.9 3.1 2.1 1.8 2.3 2.0 7

15 1 5 12 0

0 44 25 20 54 31 11 7

30 35 32 0.3 0.7 0.7 0.6 0.0 0.0 2.1 1.2 1.0 2.6 1.5 0.5 0.3 1.5 1.7 1.5 1

0 11

'0 0

0 27 9

3 25 4

1 0

19 9

2 0.0 0.0 0.5 0.0 0.0 0.0 1.3 0.4 0.1 1.2 0.2 0.0 0.0 0.9 0.4 0.1 64 3.1 80 3.9 166 8.0 140 6.8 69 3.3 67 3.2 174 8.4 158 7.6 125 6.1 190 9.2 187 9.1 143 6.9 95 4.6 137 6.6 153 7.4 118 5.7 2066 100.0 0

0.0 35 1.7 257 12.4 625 30.3 700 33.9 338 16.4 111 5.4 MISSING HOURS:

118 MEAN WIND SPEED:

14.0

Section 3 300-33 ft. Lapse Rate Wind Distributions 7/00 - 9/00

ARTIFICIAL ISLAND 07/00-09/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE:

LE -1.9 DEG C/100M CLASS A WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0

0. 0
0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

6 5

4 2

0 0

1 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.3 0.2 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0

0 1

1 0

0 1

4 0

7 2

5 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.0 0.3

0. 1 0.2 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

3 0

0 0

0 1

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 1

1 0

0 1

13 5

11 4

5 1

1 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.6 0.2 0.5 0.2 0.2 0.0 0.0 0.0 0.0 0

0.0 0

0.0 18 0.8 21 1.0 0.2 0

0.0 0

0.0 43 2.0 MEAN WIND SPEED:

8.4 MISSING

0

ARTIFICIAL ISLAND 07/00-09/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE: -1.8 TO -1.7 DEG C/1OOM CLASS B WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 4

0.2 0

0.0 0

0.0 3

0.1 3

0.1 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 2

0.1 1

0.0 2

0.1 0

0.0 4

0.2 7

0.3 5

0.2 0

0.0 9

0.4 4

0.2 0

0.0 1

0.0 2

0.1 3

0.1 0

0.0 0

0.0 4

0.2 3

0.1 0

0.0 0

0.0 5

0.2 7

0.3 0

0.0 0

0.0 2

0.1 1

0.0 2

0.1 0

0.0 0

0.0 0

0.0 3

0.1 0

0.0 2

0.1 1

0.0 2

0.1 0

0.0 4

0.2 4

0.2 0

0.0 1

0.0 39 1.8 40 1.8 14 0.6 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 5

0.2 6

0.3 1

0.0 0

0.0 1

0.0 1

0.0 5

0.2 16 0.7 13 0.6 6

0.3 7

0.3 12 0.5 5

0.2 3

0.1 5

0.2 8

0.4 94 4.3 0

0.0 MEAN WIND SPEED:

8.5 MISSING

0

ARTIFICIAL ISLAND 07/00-09/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE: -1.6 TO -1.5 DEG C/1OOM CLASS C WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

0. 0 0.0 0.0
0. 0 0.0
0. 0 0.0 0.0 0.0 0.0
0. 0
0. 0
0. 0 0.0 0.0 0.0 2

0 0

0 0

1 0

0 2

0 0

0 0

1 1

0

0. 1 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0. 1 0.0 0.0
0. 0
0. 0 0.0 0.0 0.0 130 3

0 0

2 0

3 170 7

9 7

4 2

4 6

11 0.5 0.1 0.0 0.0 0.1 0.0

0. 1
0. 5 0.3 0.4 0.3 0.2 O.1 0.2 0.3 0.5 f 2 7

2 0

3 8

3 2

5 7

5 2

4 0.5 0.3 0.0 0.0 0.1 0.0 0.1 0.4 0.1 0.1 0.2 0.3 0.2 0.1 0.2 1

1 0

0 0

0 0

4 1

1 1

2 3

0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.2 0

0.0 0

0.0 0

0.0 0

0.1 0

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 25 11 1

1 4

1 6

22 13 12 13 13 10 7

11 23 1.1 0.5 0.0 0.0 0.2 0.0 0.3 1.0 0.6 0.5 0.6 0.6 0.5 0.3 0.5 1.0 11 0.5 0

0.0 0.3 78 3.5 73 3.3 15 0.7 0

0.0 0

0.0 113 7.9 MEAN WIND SPEED:

7.9 MISSING

0

ARTIFICIAL ISLAND 07/00-09/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE: -1.4 TO -0.5 DEG C/1OOM CLASS D WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0
0. 0 0.0 0.0
0. 0 0.0 0.0 0.0 8

5 6

0 1

1 3

1 4

5 5

4 2

6 2

8 0.4 0.2 0.3 0.0 0.0

0. 0
0. 1
0. 0 0.2 0.2 0.2 0.2
0. 1 0.3
0. 1 0.4 44 25 35 21 14 13 9

29 36 35 22 17 22 17 13 23 2.0

1. 1 1.6 1.0 0.6 0.6 0.4 1.3 1.6 1.6 1.0 0.8 1.0 0.8 0.6 1.0 25 45 32 16 7

9 34 57 73 50 21 19 16 18 7

17 1.1 2.0

1. 5 0.7 0.3 0.4 1.5 2.6 3.3 2.3
1. 0
0. 9 0.7 0.8 0.3 0.8 9

13 2

1 1

0 3

39 25 6

2 1

7 5

2 1

0.4 0.6

0. 1 0.0 0.0 0.0
0. 1 1.8 1.1 0.3 0.1 0.0 0.3 0.2 0.1 0.0 0

0 0

0 0

0 0

3 1

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 86 88 75 38 23 23 49 129 139 96 50 41 47 46 24 49 3.9 4.0

3. 4
1. 7
1. 0 2.2
5. 9
6. 3 4.4
2. 3
1. 9 2.1
2. 1 1.1
2. 2 0

0.0 61 2.8 375 17.0 446 20.3 117 5.3 4

0.2 0

0.0 1003 45.6 MEAN WIND SPEED:

8.5 MISSING

3

ARTIFICIAL ISLAND 07/00-09/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE: -0.4 TO 1.5 DEG C/1OOM CLASS E WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 8

8 13 10 5

3 0

0 1

3 1

4 9

5 6

4 0.4 0.4 0.6 0.5 0.2 0.1 0.0 0.0 0.0

0. 1 0.0 0.2 0.4 0.2 0.3 0.2 39 23 17 24 17 17 6

10 11 22 32 19 20 21 41 31 1.8 1.0 0.8 1.1 0.8 0.8 0.3 0.5 0.5 1.0 1.5

0. 9
0. 9 1.0
1. 9 1.4 49 17 12 3

1 3

7 12 25 43 29 13 5

14 23 6

2.2 0.8 0.5

0. 1 0.0
0. 1 0.3 0.5 1.1 2.0 1.3 0.6 0.2 0.6 1.0 0.3 0

4 1

0 0

0 0

0 0

3 0

2 0

2 1

0 0.0 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 1 0.0 0.1 0.0
0. 1 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 96 52 43 37.

23 23 13 22 37 71 62 38 34 42 71 42 4.4 2.4 2.0 1.7 1.0 1.0 0.6 1.0 1.7 3.2 2.8 1.7 1.5

1. 9 3.2 1.9 0

0.0 80 3.6 350 15.9 262 11.9 13 0.6 1

0.0 0

0.0 706 32.1 MEAN WIND SPEED:

6.9 MISSING

3

ARTIFICIAL ISLAND 07/00-09/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE:

1.6 TO 4.0 DEG C/1OOM CLASS F WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 6

0.3 2

0.1 1

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 1

0.0 0

0.0 3

0.1 21 1.0 16 0.7 15 0.7 0

0.0 18 0.8 0

0.0 12 0.5 0

0.0 9

0.4 0

0.0 3

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 4

0.2 6

0.3 6

0.3 0

0.0 2

0.1 3

0.1 3

0.1 1

0.0 3

0.1 1

0.0 8

0.4 7

0.3 14 0.6 6

0.3 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 38 1.7 15 0.7 24 1.1 14 0.6 10 0.5 3

0.1 1

0.0 0

0.0 0

0.0 10 0.5 6

0.3 5

0.2 5

0.2 5

0.2 15 0.7 23 1.0 0

0.0 16 0.7 118 5.4 40 1.8 0.0 0

0.0 0

0.0 174 7.9 MEAN WIND SPEED:

6.0 MISSING

1

ARTIFICIAL ISLAND 07/00-09/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE:

GT 4.0 DEG C/1OOM CLASS G WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18. 5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1

4 3

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.2

0. 1 0.0 0.0 0.0 0.0
0. 0
0. 0 0.0 0.0 0.0
0. 0 0.0 0.0 0.0 0

0

.0 0

0 0

0 0

0 0

.0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1

4 3

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0.0 0

0.0 0.4 0

0.0 0

0.0 0

0.0 0

0.0 8

0.4 MEAN WIND SPEED:

5.9 MISSING

0

ARTIFICIAL ISLAND 07/00-09/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

ALL STABILITY CLASSES WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12. 5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT 19 0.9 116 5.3 106 4.8 10 0.5 13 0.6 73 3.3 72 3.3 18 0.8 25 1.1 74 3.4 46 2.1 3

0.1 12 0.5 57 2.6 21 1.0 1

0.0 7

0.3 42 1.9 11 0.5 1

0.0 5

0.2 33 1.5 13 0.6 0

0.0 4

0.2 20 0.9 46 2.1 5

0.2 1

0.0 59 2.7 88 4.0 51 2.3 7

0.3 68 3.1 105 4.8 26 1.2 9

0.4 76 3.5 111 5.0 10 0.5 6

0.3 73 3.3 60 2.7 3

0.1 8

0.4 47 2.1 54 2.5 5

0.2 12 0.5 49 2.2 28 1.3 13 0.6 13 0.6 46 2.1 35 1.6 10 0.5 9

0.4 70 3.2 42 1.9 5

0.2 15 0.7 83 3.8 44 2.0 2

0.1 SUM PERCENT SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 3

0.1 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

- 0.0 251 11.4 176 8.0 148 6.7 91 4.1 61 2.8 51 2.3 75 3.4 202 9.2 207 9.4 206 9.4 142 6.5 114 5.2 102 4.6 104 4.7 126 5.7 145 6.6 0

0.0 165 7.5 986 44.8 882 40.1 163 7.4 0.2 0

0.0 2201 100.0 MISSING HOURS:

7 MEAN WIND SPEED:

7.7

ARTIFICIAL ISLAND 07/00-09/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

DIRECTION VS SPEED ONLY WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18. 5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 19 0.9 116 5.3 106 4.8 10 0.5 0

0.0 13 0.6 73 3.3 72 3.3 18 0.8 0

0.0 25 1.1 74 3.4 46 2.1 3

0.1 0

0.0 12 0.5 57 2.6 21 1.0 1

0.0 0

0.0 7

0.3 42 1.9 11 0.5 1

0.0 0

0.0 5

0.2 33 1.5 13 0.6 0

0.0 0

0.0 4

0.2 20 0.9 46 2.1 5

0.2 0

0.0 1

0.0 59 2.7 88 4.0 51 2.3 0

0.0 7

0.3 68 3.1 105 4.8 26 1.2 0

0.0 9

0.4 76 3.5 111 5.0 10 0.5 0

0.0 6

0.3 73 3.3 60 2.7 3

0.1 0

0.0 8

0.4 47 2.1 54 2.5 5

0.2 0

0.0 12 0.5 49 2.2 28 1.3 13 0.6 0

0.0 13 0.6 46 2.1 35 1.6 10 0.5 0

0.0 9

0.4 70 3.2 42 1.9 5

0.2 0

0.0 15 0.7 83 3.8 44 2.0 2

0.1 0

0.0 165 7.5 986 44.8 882 40.1 163 7.4 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 3

0.1 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 5

0.2 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 251 11.4 176 8.0 148 6.7 91 4.1 61 2.8 51 2.3 75 3.4 202 9.2 207 9.4 206 9.4 142 6.5 114 5.2 102 4.6 104 4.7 126 5.7 145 6.6 0

0.0 2201 100.0 MISSING HOURS:

7 MEAN WIND SPEED:

7.7

ARTIFICIAL ISLAND 07/00-09/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T:

(300-33FT)

LAPSE RATE:

LE -1.9 DEG C/1OOM CLASS A WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0
0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0
0. 0 0.0 0.0 0.0 0

0 0

0 0

0 0

4 4

5 1

0 0

0 1

0 0.0 0.0 0.0

0. 0 0.0 0.0
0. 0 0.2 0.2 0.2
0. 0 0.0 0.0 0.0 0.0 0.0 0

1 1

0 0

1 5

0 3

6 2

1 0

0 0

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.0

0. 1 0.3
0. 1 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

2 0

1 1

2 1

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

1 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 1

1 0

0 1

12 4

9 8

4 2

0 1

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.5 0.2 0.4 0.4 0.2

0. 1 0.0 0.0 0.0 0

0.0 0

0.0 15 0.7 20 0.9 7

0.3 0.0 0

0.0 43 1.9 MEAN WIND SPEED:

9.9 MISSING

0

ARTIFICIAL ISLAND 07/00-09/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE: -1.8 TO -1.7 DEG C/1OOM CLASS B WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5

3. 6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 2

0 1

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 3

0 2

0 0

0 1

4 4

3 4

1 2

0 1

1

0. 1 0.0 0.1 0.0 0.0 0.0 0.0 0.2 0.2
0. 1 0.2 0.0
0. 1 0.0 0.0 0.0 4

1

.3 0

2 0

5 4

4 8

1 0

1 3

0.2 0.0

0. 1 0.0
0. 1 0.0 0.0 0.2 0.0 0.2 0.2 0.4 0.0 0.0 0.0
0. 1 2

1 1

0 0

0 5

5 0

0 1

2 1

2 2

0 0.1 0.0 0.0 0.0 0.0 0.0 0.2 0.2 0.0 0.0 0.0

0. 1 0.0
0. 1 0.1 0.0 0

0 0

0 0

0 1

1 0

0 0

0 0

1 2

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 9

2 6

0 2

0 8

15 7

7 10 11 4

3 6

4 0.4 0.1 0.3 0.0 0'. 1 0.0 0.4 0.7 0.3 0.3 0.5 0.5 0.2 0.1 0.3 0.2 0

0.0 3

0.1 26 1.2 38 1.7 22 1.0 5

0.2 0

0.0 94 4.3 MEAN WIND SPEED:

10.1 MISSING:

0

ARTIFICIAL ISLAND 07/00-09/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE: -1.6 TO -1.5 DEG C/lOOM CLASS C WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 6

0.3 13 0.6 0

0.0 2

0.1 8

0.4 0

0.0 0

0.0 4

0.2 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 1

0.0 1

0.0 0

0.0 0

0.0 2

0.1 2

0.1 1

0.0 11 0.5 3

0.1 1

0.0 3

0.1 1

0.0 0

0.0 5

0.2 4

0.2 1

0.0 6

0.3 5

0.2 0

0.0 6

0.3 3

0.1 0

0.0 3

0.1 1

0.0 0

0.0 3

0.1 2

0.1 1

0.0' 1

0.0 1

0.0 1

0.0 14 0.6 7

0.3 2

0.1 1

0.0 2

0.1 0

0.0 2

0.1 0

0.0 3

0.1 6

0.3 2

0.1 1

0.0 1

0.0 8

0.4 6

0.3 0

0.0 1

0.0 9

0.4 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 1

0.0 0

0.0 1

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 22 1.0 11 0.5 6

0.3 0

0.0 3

0.1 2

0.1 8

0.4 22 1.0 7

0.3 11 0.5

  • 13 0.6 18 0.8 10 0.5 5

0.2 4

0.2 31 1.4 0

0.0 7

0.3 64 2.9 54 2.4 44 2.0 0.2 0

0.0 173 7.8 MEAN WIND SPEED:

9.4 MISSING

0

ARTIFICIAL ISLAND 07/00-09/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T:

(300-33FT)

LAPSE RATE: -1.4 TO -0.5 DEG C/1OOM CLASS D WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7. 5 7.6-12.5

12. 6-18. 5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 4

0.2 5

0.2 4

0.2 2

0.1 0

0.0 1

0.0 3

0.1 1

0.0 1

0.0 5

0.2 3

0.1 5

0.2 2

0.1 2

0.1 3

0.1 5

0.2 19 0.9 33 1.5 11 0.5 11 0.5 34 1.5 23 1.0 15 0.7 38 1.7 27 1.2 18 0.8 18 0.8 12 0.5 6

0.3 8

0.4 5

0.2 2

0.1 16 0.7 2

0.1 1

0.0 18 0.8 30 1.4 19 0.9 44 2.0 54 2.4 19 0.9 31 1.4 39 1.8 22 1.0 42 1.9 28 1.3 20 0.9 32 1.4 19 0.9 9

0.4 21 1.0 10 0.5 14 0.6 21 1.0 11 0.5 17 0.8 8

0.4 9

0.4 13 0.6 10 0.5 10 0.5 16 0.7 22 1.0 3

0.1 0

0.0 8

0.4 6

0.3 1

0.0 0

0.0 0

0.0 5

0.2 17 0.8 3

0.1 2

0.1 1

0.0 1

0.0 0

0.0 1

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 3

0.1 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 67 3.0 81 3.7 90 4.1 51 2.3 19 0.9 21 1.0 60 2.7 135 6.1 94 4.3 99 4.5 75 3.4 46 2.1 48 2.2 37 1.7 36 1.6 47 2.1 0

0.0 46 2.1 221 10.0 396 17.9 293 13.3 46 2.1 4

0.2 1006 45.6 MEAN WIND SPEED:

10.7 MISSING:

0

ARTIFICIAL ISLAND 07/00-09/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE: -0.4 TO 1.5 DEG C/1OOM CLASS E WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 2

0.1 2

0.1 5

0.2 5

0.2 5

0.2 2

0.1 1

0.0 1

0.0 0

0.0 1

0.0 3

0.1 1

0.0 3

0.1 4

0.2 2

0.1 1

0.0 9

0.4 25 1.1 15 0.7 20 0.9 41 1.9 24 1.1 13 0.6 14 0.6 10 0.5 5

0.2 14 0.6 9

0.4 5

0.2 13 0.6 0

0.0 7

0.3 5

0.2 2

0.1 5

0.2 12 0.5 5

0.2 7

0.3 15 0.7 2

0.1 5

0.2 10 0.5 9

0.4 4

0.2 28 1.3 28 1.3 14 0.6 52 2.4 19 0.9 10 0.5 18 0.8 6

0.3 20 0.9 20 0.9 4

0.2 18 0.8 13 0.6 3

0.1 11 0.5 28 1.3 23 1.0 7

0.3 19 0.9 14 0.6 4

0.2 0

0.0 3

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 55 2.5 87 3.9 45 2.0 33 1.5 23 1.0 16 0.7 23 1.0 25 1.1 24 1.1 62 2.8 88 4.0 35 1.6 48 2.2 38 1.7 64 2.9 43 1.9 0

0.0 38 1.7 160 7.2 327 14.8 173 7.8 10 0.5 0.0 709 32.1 MEAN WIND SPEED:

10.0 MISSING:

0

ARTIFICIAL ISLAND 07/00-09/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE:

1.6 TO 4.0 DEG C/100M CLASS F WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

1 4

1 0

1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.2 0.0 0.0 0.0 2

2 2

4 7

6 7

1 0

0 0

1 3

2 2

0.1

0. 1
0. 1 0.2 0.3 0.3 0.3 0.0 0.0 0.0 0.0 0.0 0.0
0. 1
0. 1
0. 1 1.1 24 7

5 8

4 1

0 0

4 12 3

2 2

6 7

0.5 13 0.6 1.1 2

0.1 0.3 0

0.0 0.2 0

0.0 0.4 0

0.0 0.2 0

0.0 0.0 1

0.0 0.0 0

0 0

0.0 0

0.0 0.2 2

0.1 0.5 1

0.0 0.1 1

0.0 0.1 0

0.0 0.1 0

0.0 0.3 3

0.1 0.3 8

0.4 1

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 27 28 9

9 15 10 9

1 0

6 13 6

7 6

11 18 1.2 1.3 0.4 0.4 0.7 0.5 0.4 0.0 0.0 0.3 0.6 0.3 0.3 0.3 0.5 0.8 0

0.0 7

0.3 40 1.8 96 4.3 31 1.4 0.0 0

0.0 175 7.9 MEAN WIND SPEED:

9.6 MISSING

0

ARTIFICIAL ISLAND 07/00-09/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE:

GT 4.0 DEG C/1OOM CLASS G WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18. 5
18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0
0. 0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0

0. 0 0.0 0.0 0.0
0. 0
0. 0 0.0
0. 0 0.0 0.0 0.0 0.0
0. 0 0.0 0

0 0

2 0

0 0

0 0

0 0

0 0

0 0

0

0. 0 0.0
0. 0
0. 1 0.0 0.0 0.0 0.0 0.0
0. 0
0. 0
0. O 0.0
0. 0 0.0 0.0 0

0 4

2 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.2 0.1 0.0 0.0 0.0 0.0 0.0

0. 0
0. 0 0.0
0. 0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 4

4 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.2 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0.0 0

0.0 2

0.1 6

0.3 0

0.0 0

0.0 0

0.0 8

0.4 MEAN WIND SPEED:

9.0 MISSING

0

ARTIFICIAL ISLAND 07/00-09/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

ALL STABILITY CLASSES WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 7

0.3 7

0.3 9

0.4 7

0.3 5

0.2 4

0.2 4

0.2 3

0.1 4

0.2 6

0.3 8

0.4 7

0.3 9

0.4 7

0.3 6

0.3 8

0.4 39 1.8 86 3.9 43 1.9 5

0.2 35 1.6 108 4.9 51 2.3 8

0.4 32 1.4 71 3.2 40 1.8 9

0.4 29 1.3 40 1.8 21 1.0 1

0.0 19 0.9 31 1.4 7

0.3 0

0.0 16 0.7 25 1.1 4

0.2 0

0.0 16 0.7 35 1.6 44 2.0 7

0.3 46 2.1 72 3.3 69 3.1 20 0.9 35 1.6 43 1.9 50 2.3 3

0.1 39 1.8 85 3.8 60 2.7 4

0.2 45 2.0 111 5.0 42 1.9 1

0.0 27 1.2 55 2.5 29 1.3 2

0.1 40 1.8 46 2.1 23 1.0 1

0.0 41 1.9 25 1.1 14 0.6 2

0.1 29 1.3 46 2.1 39 1.8 2

0.1 40 1.8 58 2.6 34 1.5 2

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 3

0.1 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 180 8.2 209 9.5 161 7.3 98 4.4 62 2.8 49 2.2 109 4.9 210 9.5 136 6.2 194 8.8 207 9.4 120 5.4 119 5.4 89 4.0 122 5.5 143 6.5 0

0.0 101 4.6 528 23.9 937 42.4 570 25.8 67 3.0 5

0.2 2208 100.0 MISSING HOURS:

0 MEAN WIND SPEED:

10.3

ARTIFICIAL ISLAND 07/00-09/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

DIRECTION VS SPEED ONLY WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE EN E E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 7

0.3 39 1.8 86 3.9 43 1.9 5

0.2 0

0.0 7

0.3 35 1.6 108 4.9 51 2.3 8

0.4 0

0.0 9

0.4 32 1.4 71 3.2 40 1.8 9

0.4 0

0.0 7

0.3 29 1.3 40 1.8 21 1.0 1

0.0 0

0.0 5

0.2 19 0.9 31 1.4 7

0.3 0

0.0 0

0.0 4

0.2 16 0.7 25 1.1 4

0.2 0

0.0 0

0.0 4

0.2 16 0.7 35 1.6 44 2.0 7

0.3 0

0.0 3

0.1 46 2.1 72 3.3 69 3.1 20 0.9 0

0.0 4

0.2 35 1.6 43 1.9 50 2.3 3

0.1 0

0.0 6

0.3 39 1.8 85 3.8 60 2.7 4

0.2 0

0.0 8

0.4 45 2.0 111 5.0 42 1.9 1

0.0 0

0.0 7

0.3 27 1.2 55 2.5 29 1.3 2

0.1 0

0.0 9

0.4 40 1.8 46 2.1 23 1.0 1

0.0 0

0.0 7

0.3 41 1.9 25 1.1 14 0.6 2

0.1 0

0.0 6

0.3 29 1.3 46 2.1 39 1.8 2

0.1 0

0.0 8

0.4 40 1.8 58 2.6 34 1.5 2

0.1 0

0.0 101 4.6 528 23.9 937 42.4 570 25.8 67 3.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 3

0.1 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 180 8.2 209 9.5 161 7.3 98 4.4 62 2.8 49 2.2 109 4.9 210 9.5 136 6.2 194 8.8 207 9.4 120 5.4 119 5.4 89 4.0 122 5.5 143 6.5 5

0.2 2208 100.0 MISSING HOURS:

0 MEAN WIND SPEED:

10.3

ARTIFICIAL ISLAND 07/00-09/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE:

LE -1.9 DEG C/lOOM CLASS A WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 2

4 2

5 0

0 0

1 0

0 0.0 0.0 0.0 0.0 0.0 0.0

0. 1 0.2
0. 1 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0

0

.0 1

0 0

2 4

0 6

2 1

0 0

0 0

0.0 0.0 0.0 0.0 0.0 0.0

0. 1 0.2 0.0 0.3
0. 1 0.0 0.0 0.0 0.0 0.0 0

0 0

1 0

0 2

0 0

4 0

4 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.2 0.0 0.2 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

1 0

0 0

0 1

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

2 0

0 6

9 2

15 2

5 1

1 0

0 0.0 0.0 0.0 0.1 0.0 0.0 0.3 0.4

0. 1 0.7 0.1 0.2 0.0 0.0 0.0 0.0 0

0.0 0

0.0 14 0.6 16 0.7 11 0.5 2

0.1 0

0.0 43 1.9 MEAN WIND SPEED:

10.5 MISSING:

0

ARTIFICIAL ISLAND 07/00-09/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE: -1.8 TO -1.7 DEG C/1OOM CLASS B WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

1 2

0 0

0 0

0 1

0 0.0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 1

3 2

5 3

0 2

0 2

1 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 1
0. 1 0.2 0.1 0.0 0.1 0.0 0.1 0.0 2

5

  • 0 0

2 0

3 3

2 4

4 6

0 1

1 7

0. 1 0.2 0.0
  • 0.0 0.1 0.0 0.1
0. 1 0.1 0.2 0.2 0.3 0.0 0.0 0.0 0.3 0

2 0

0 0

0 6

2 0

3 2

3 0

0 0

2 0.0 0.1 0.0 0.0 0.0 0.0 0.3

0. 1 0.0 0.1 0.1 0.1 0.0 0.0 0.0 0.1 0

0 0

0 0

0 3

1 0

0 0

0 2

3 2

0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 2

7 0

0 2

0 13 10 6

12 9

9 4

4 6

10 0.1 0.3 0.0 0.0 0.1 0.0 0.6 0.5 0.3 0.5 0.4 0.4 0.2 0.2 0.3 0.5 0

0.0 4

0.2 19 0.9 40 1.8 20 0.9 11 0.5 0

0.0 94 4.3 MEAN WIND SPEED:

10.8 MISSING:

0

ARTIFICIAL ISLAND 07/00-09/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE: -1.6 TO -1.5 DEG C/1OOM CLASS C WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1

0 0

0 0

0 1

1 2

0 1

0 0

1 1

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 4

1 0

0 2

2 4

7 4

4 6

5 3

3 7

6 0.2 0.0 0.0 0.0

0. 1
0. 1 0.2 0.3 0.2 0.2 0.3 0.2
0. 1 0.1 0.3 0.3 1 1 4

0 0

0 0

3 2

2 4

6 1

3 0

4 1 6 0.5 0.2 0.0 0.0 0.0 0.0 0.1

0. 1 0.1 0.2 0.3 0.0 0.1 0.0 0.2 0.7 1

4 1

1 1

1 7

1 3

0 4

4 5

0 6

5 0.0 0.2 0.0 0.0 0.0 0.0 0.3 0.0 0.1 0.0 0.2 0.2 0.2 0.0 0.3 0.2 0

0 0

0 0

0 1

1 0

1 0

3 0

0 0

1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 17 9

1 1

3 3

16 12 11 9

17 13 11 4

18 28 0.8 0.4 0.0 0.0 0.1 0.1 0.7 0.5 0.5 0.4 0.8 0.6 0.5 0.2 0.8 1.3 0

0.0 8

0.4 58 2.6 56 2.5 44 2.0 7

0.3 0

0.0 173 7.8 MEAN WIND SPEED:

10.0 MISSING:

0

I ARTIFICIAL ISLAND 07/00-09/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE: -1.4 TO -0.5 DEG C/1OOM CLASS D WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 4

0.2 4

0.2 1

0.0 0

0.0 1

0.0 3

0.1 3

0.1 4

0.2 4

0.2 2

0.1 1

0.0 4

0.2 4

0.2 3

0.1 3

0.1 4

0.2 7

0.3 27 1.2 18 0.8 6

0.3 29 1.3 38 1.7 11 0.5 29 1.3 19 0.9 11 0.5 10 0.5 14 0.6 4

0.2 7

0.3 6

0.3 1

0.0 11 0.5 12 0.5 7

0.3 22 1.0 41 1.9 17 0.8 35 1.6 54 2.4 19 0.9 31 1.4 35 1.6 16 0.7 28 1.3 39 1.8 12 0.5 25 1.1 22 1.0 11 0.5 13 0.6 11 0.5 13 0.6 19 0.9 8

0.4 15 0.7 11 0.5 9

0.4 11 0.5 11 0.5 8

0.4 12 0.5 35 1.6 8

0.4 7

0.3 16 0.7 3

0.1 2

0.1 0

0.0 0

0.0 15 0.7 15 0.7 6

0.3 10 0.5 1

0.0 4

0.2 3

0.1 6

0.3 3

0.1 2

0.1 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 2

0.1 4

0.2 1

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 64 2.9 93 4.2 63 2.9 37 1.7 18 0.8 29 1.3 92 4.2 126 5.7 96 4.3 95 4.3 61 2.8 43 1.9 47 2.1 44 2.0 36 1.6 62 2.8 0

0.0 45 2.0 173 7.8 343 15.5 342 15.5 93 4.2 10 0.5 1006 45.6 MEAN WIND SPEED:

11.9 MISSING:

0

ARTIFICIAL ISLAND 07/00-09/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE: -0.4 TO 1.5 DEG C/1OOM CLASS E WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18. 5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1

1 3

0 2

0 3

2 3

0 2

1 1

2 1

0.0 0.0 0.1 0.0

0. 1 0.0
0. 1
0. 1
0. 1 0.0
0. 1 0.0 0.0
0. 1 0.0 0.0

.7 1 0 6

4 5

4 4

5 10 6

5 1 0 1 9 1 5 5

5 0.3 0.5 0.3 0.2 0.2 0.2 0.2 0.2 0.5 0.3 0.2 0.5

0. 9 0.7 0.2 0.2 22 12

' 3 8

9 6

12 10 9

13 24 12 20 12 23 13

1. 0 0.5
0. 1 0.4 0.4 0.3 0.5 0.5 0.4 0.6
1. 1 0.5
0. 9 0.5 1.0 0.6 36 34 6

1 7 6

5 6

3 22 38 31 17 6

16 20 22 1.6 1.5 0.3 0.8 0.3 0.2 0.3

0. 1 1.0 1.7 1.4 0.8 0.3 0.7
0. 9 1.0 10 6

0 0

0 0

0 0

3 19 6

2 1

3 10 8

0.5 0.3 0.0 0.0 0.0 0.0 0.0 0.0 0.1

0. 9 0.3
0. 1 0.0 0.1 0.5 0.4 0

2 1

0 0

0 0

0 0

0 0

1 0

0 0

1 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 76 65 19 29 22 15 25 20 47 76 68 43 47 48 59 50 3.4 2.9

0. 9
1. 3 1.0 0.7 1.1
0. 9 2.1 3.4 3.1 1.9 2.1 2.2 2.7 2.3 0

0.0 23 1.0 120 5.4 208 9.4 285 12.9 68 3.1 5

0.2 709 32.1 MEAN WIND SPEED:

12.4 MISSING:

0

ARTIFICIAL ISLAND 07/00-09/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND; 300 FT DELTA T: (300-33FT)

LAPSE RATE:

1.6 TO 4.0 DEG C/1OOM CLASS F WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7. 5 7.6-12.5 12.6-18.5

18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0
0. 0 0.0
0. 0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 1

1 0

0 1

1 1

0 0

2 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0
0. 1 0.0 0.0 1

0 0

2 5

1 4

4 3

0 1

2 2

1 2

0 0.0 0.0 0.0 0.1 0.2 0.0 0.2 0.2 0.1 0.0 0.0 0.1 0.1 0.0 0.1 0.0 8

2 2

3 9

4 2

0 0

4 4

1 1

1 2

7 0.4 0.1

0. 1
0. 1 0.4 0.2
0. 1 0.0 0.0 0.2 0.2 0.0 0.0 0.0
0. 1 0.3 1 7 1 2 1

1 6

1 1

0 1

8 2

2 2

0 1 0 1 2 0.8 0.5 0.0 0.0 0.3 0.0 0.0 0.0 0.0 0.4 0.1 0.1 0.1 0.0 0.5 0.5 3

3 0

0 0

0 0

0 0

1 2

0 0

0 4

1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.2 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 29 17 3

6 21 7

7 4

5 14 10 5

5 4

1 8 20 1.3 0.8 0.1 0.3 1.0 0.3 0.3 0.2 0.2 0.6 0.5 0.2 0.2 0.2 0.8

0. 9 0

0.0 7

0.3 28 1.3 50 2.3 76 3.4 14 0.6 0

0.0 175 7.9 MEAN WIND SPEED:

12.4 MISSING:

0

ARTIFICIAL ISLAND 07/00-09/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE:

GT 4.0 DEG C/1OOM CLASS G WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7. 5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W-WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

2 3

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 3

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 3

2 3

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0.0 0

0.0 5

0.2 3

0.1 0

0.0 0

0.0 0

0.0 8

0.4 MEAN WIND SPEED:

7.9 MISSING

0

ARTIFICIAL ISLAND 07/00-09/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

ALL STABILITY CLASSES WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18. 5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

0. 0 0.0 0.0 0.0 0.0
0. 0
0. 0 0.0
0. 0
0. 0 0.0 0.0 0.0 0.0 0.0 0.0 6

5 4

0 4

4 7

8 12 3

5 5

5 8

6 5

0.3 0.2 0.2 0.0 0.2 0.2 0.3 0.4

0. 5
0. I 0.2 0.2 0.2 0.4 0.3 0.2 1 9 1 7 1 7 1 9 1 9 8

22 4 0 4 0 36 2 7 2 8 3 9 35 27 2 4

0. 9 0.8 0.8
0. 9
0. 9 0.4 1.0 1.8 1.8 1.6 1.2 1.3 1.8 1.6 1.2 1.1 70 52 37 22 27 21 44 54 44 59 65 34 43 25 41 78 3.2 2.4 1.7 1.0 1.2 1.0 2.0 2.4 2.0 2.7 2.9 1.5
1. 9 1.1
1. 9 3.5 72 90 27 34 19 19 63 60 61 92 61 41 21 25 44 49 3.3 4.1 1.2 1.5
0. 9
0. 9 2.9 2.7 2.8 4.2 2.8
1. 9 1.0 1.1 2.0 2.2 20 25 3

2 0

0 19 18 9

31 9

9 7

12 19 12 0.9 1.1 0.1 0.1 0.0 0.0

0. 9 0.8 0.4 1.4 0.4 0.4 0.3 0.5
0. 9 0.5 1

2 1

0 0

2 4

1 1

0 0

1 0

0 0

2 0.0 0.1 0.0 0.0 0.0 0.1 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 188 191 89 77 69 54 159 181 167 221 167 118 115 105 137 170 8.5 8.7 4.0 3.5 3.1 2.4 7.2 B.2 7.6 10.0 7.6 5.3 5.2 4.8 6.2 7.7 0

0.0 87 3.9 417 18.9 716 32.4 778 35.2 195 8.8 15 0.7 2208 100.0 MISSING HOURS:

0 MEAN WIND SPEED:

11.8

ARTIFICIAL ISLAND 07/00-09/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

DIRECTION VS SPEED ONLY WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 6

0.3 19 0.9 70 3.2 72 3.3 5

0.2 17 0.8 52 2.4 90 4.1 4

0.2 17 0.8 37 1.7 27 1.2 0

0.0 19 0.9 22 1.0 34 1.5 4

0.2 19 0.9 27 1.2 19 0.9 4

0.2 8

0.4 21 1.0 19 0.9 7

0.3 22 1.0 44 2.0 63 2.9 8

0.4 40 1.8 54 2.4 60 2.7 12 0.5 40 1.8 44 2.0 61 2.8 3

0.1 36 1.6 59 2.7 92 4.2 5

0.2 27 1.2 65 2.9 61 2.8 5

0.2 28 1.3 34 1.5 41 1.9 5

0.2 39 1.8 43 1.9 21 1.0 8

0.4 35 1.6 25 1.1 25 1.1 6

0.3 27 1.2 41 1.9 44 2.0 5

0.2 24 1.1 78 3.5 49 2.2 20 0.9 25 1.1 3

0.1 2

0.1 0

0.0 0

0.0 19 0.9 18 0.8 9

0.4 31 1.4 9

0.4 9

0.4 7

0.3 12 0.5 19 0.9 12 0.5 1

0.0 2

0.1 1

0.0 0

0.0 0

0.0 2

0.1 4

0.2 1

0.0 1

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 2

0.1 188 8.5 191 8.7 89 4.0 77 3.5 69 3.1 54 2.4 159 7.2 181 8.2 167 7.6 221 10.0 167 7.6 118 5.3 115 5.2 105 4.8 137 6.2 170 7.7 0

0.0 87 3.9 417 18.9 716 32.4 778 35.2 195 8.8 15 0.7 2208 100.0 MISSING HOURS:

0 MEAN WIND SPEED:

11.8

Section 4 300-33 ft. Lapse Rate Wind Distributions 10/00 - 12/00

ARTIFICIAL ISLAND 10/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE:

LE -1.9 DEG C/1OOM CLASS A WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

1 0

2 0

0 1

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 1 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 2

0 0

0 0

0 2

0 3

2 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0

0. 1 0.0 0.1 0.1 0

0 0

0 0

0 0

0 0

0 0

0 8

2 13 10 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.4 0.1 0.6 0.5 2

0 0

0 0

0 0

0 0

0 0

0 0

0 1

1 0.1 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 2

0 0

0 0

0 2

1 0

2 0

0 11 2

17 13 0.1 0.0 0.0 0.0 0.0 0.0

0. 1 0.0 0.0 0.1 0.0 0.0 0.5 0.1 0.8 0.6 0

0.0 0

0.0 4

0.2 9

0.4 33 1.6 4

0.2 0

0.0 50 2.4 MEAN WIND SPEED:

13.7 MISSING:

0

ARTIFICIAL ISLAND 10/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T:

(300-33FT)

LAPSE RATE: -1.8 TO -1.7 DEG C/1OOM CLASS B WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18.5
18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

0. 0 0.0 0.0 0.0
0. 0 0.0
0. 0
0. 0 0.0 0.0 0.0 0.0 0.0 0.0
0. 0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0
0. 0 0.0 3

1 0

0 0

0 0

2 2

3 0

3 3

3 5

4 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1

0. 1 0.0 0.1
0. 1 0.1 0.2 0.2 6

2

'I1 0

1 1

1 0

1 0

0 3

3 5

11 12 0.3

0. 1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0. 1 0.1 0.2 0.5 0.6 1

0 0

0 0

0 0

0 0

0 0

0 1 3 7

9 9

0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.6 0.3 0.4 0.4 1

0 0

0 0

0 0

0 0

0 0

0 0

0 4

2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 11 3

1 0

1 1

1 2

3 3

0 6

1 9 15 2 9 27 0.5 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.0 0.3

0. 9 0.7 1.4 1.3 0

0.0 0

0.0 29 1.4 47 2.2 39 1.8 7

0.3 0

0.0 122 5.8 MEAN WIND SPEED:

11.2 MISSING:

3

ARTIFICIAL ISLAND 10/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE: -1.6 TO -1.5 DEG C/1OOM CLASS C WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 3

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 8

0.4 4

0.2 1

0.0 6

0.3 7

0.3 0

0.0 2

0.1 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 1

0.0 4

0.2 0

0.0 3

0.1 3

0.1 1

0.0 2

0.1 2

0.1 0

0.0 4

0.2 1

0.0 0

0.0 4

0.2 4

0.2 0

0.0 6

0.3 6

0.3 9

0.4 3

0.1 4

0.2 6

0.3 4

0.2 11 0.5 11 0.5 4

0.2 5

0.2 6

0.3 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 2

0.1 3

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 14 0.7 13 0.6 3

0.1 0

0.0 1

0.0 0

0.0 1

0.0 5

0.2 10 0.5 4

0.2 5

0.2 8

0.4 23 1.1 15 0.7 30 1.4 15 0.7 0

0.0 0.2 49 2.3 52 2.5 34 1.6 7

0.3 1

0.0 147 7.0 MEAN WIND SPEED:

10.0 MISSING:

4

ARTIFICIAL ISLAND 10/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE: -1.4 TO -0.5 DEG C/1OOM CLASS D WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 1

5 1

3 5

1 1

5 7

2 2

1 1

2 3

8 0.0 0.2 0.0 0.1 0.2 0.0 0.0 0.2 0.3

0. 1
0. 1 0.0 0.0
0. 1
0. 1 0.4 1 7 1 5 22 1 6 1 5 7

1 0 1 5 1 5 1 7 9

1 4 1 2 1 9 1 1 1 4 0.8 0.7 1.0 0.8 0.7 0.3

0. 5 0.7 0.7 0.8 0.4 0.7 0.6 0.9 0.5 0.7

.9 6

I 4 8

2 0

5 15 20 9

5 11 48 38 46 23 0.4 0.3 0.2 0.4

0. 1 0.0 0.2 0.7
0. 9 0.4 0.2 0.5 2.3 1.8 2.2 1.1 1

0 0

0 3

1 1

4 2

1 0

1 4 5 55 51 21 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.2 0.1 0.0 0.0 0.0 2.1 2.6 2.4 1.0 0

0 0

0 0

0 0

0 0

0 0

2 12 7

7 0

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.6 0.3 0.3 0.0 0

0 0

0 0

0 0

0 0

0 0

0 1

1 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 28 26 27 27 25 9

17 39 44 29 16 29 119 122 118 66 1.3 1.2 1.3 1.3 1.2 0.4 0.8 1.8 2.1 1.4 0.8 1.4 5.6 5.8 5.6 3.1 0

0.0 48 2.3 228 10.8 249 11.8 186 8.8 28 1.3 0.1 741 35.1 MEAN WIND SPEED:

MISSING:

9.8 51

ARTIFICIAL ISLAND 10/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE: -0.4 TO 1.5 DEG C/1OOM CLASS E WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18. 5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE s

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 D

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 10 2

9 a

8 0

3 3

3 2

0 2

7 7

5 6

0.5

0. 1 0.4 0.4 0.4
0. 0
0. 1
0. 1
0. 1
0. 1 0.0
0. 1 0.3 0.3 0.2 0.3 38 25 17 28 17 7

14 8

9 8

9 22 21 25 44 33 1.8 1.2 0.8 1.3 0.8 0.3 0.7 0.4 0.4 0.4 0.4 1.0 1.0 1.2 2.1 1.6 45 2.1 5

0.2

  • 4 0.2 3

0.1 2

0.1 1

0.0 0

0.0 9

0.4 3

0.1 2

0.1 11 0.5 14 0.7 16 0.8 25 1.2 86 4.1 43 2.0 7

0 0

0 2

2 3

3 5

1 2

1 8

1 5

8 0.3 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.0 0.1 0.0 0.4 0.0 0.2 0.4 0

0 0

0 0

0 0

0 0

0 1

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 100 32 30 39 29 10 20 23 20 13 23 39 52 58 140 90 4.7 1.5 1.4 1.8 1.4 0.5

0. 9 1.1 0.9 0.6 1.1 1.8 2.5 2.7 6.6 4.3 0

0.0 75 3.6 325 15.4 269 12.7 48 2.3 1

0.0 0

0.0 718 34.0 MEAN WIND SPEED:

7.4 MISSING

20

ARTIFICIAL ISLAND 10/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE:

1.6 TO 4.0 DEG C/1OOM CLASS F WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 4

3 3

2 3

1 0

1 4

6 2

5 5

5 2

0.2

0. 1 0.1 0.1 0.1 0.0 0.0 0.0 0.2 0.0 0.3
0. 1 0.2 0.

0.2

0. 1 1 0 1 5 1 5 1 3 1 2 2

2 5

6 4

7 1 4 1 1 1 3 1 6 1 5 0.5 0.7 0.7 0.6 0.6 0.1

0. 1 0.2 0.3 0.2 0.3 0.7 0.5 0.6 0.8 0.7 1

3 0

0 0

1 0

1 2

6 1

1 6

10 0.0 0.1

0. 1 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0. 1 0.3 0.0
0. 0 0.3 0.5 0

0 0

0 0

0 3

0 3

0 0

7 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.1 0.0 0.0 0.3 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 15 21 20 15 15 3

6 6

14 6

15 29 17 19 27 27 0.7 1.0 0.9 0.7 0.7 0.1 0.3 0.3 0.7 0.3 0.7 1.4 0.8

0. 9 1.3 1.3 0

0.0 47 2.2 160 7.6 35 1.7 13 0.6 0

0.0 0

0.0 255 12.1 MEAN WIND SPEED:

MISSING:

5.9 16

ARTIFICIAL ISLAND 10/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE:

GT 4.0 DEG C/100M CLASS G WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5

3. 6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

1 1

1 2

0 0

0 0

0 1

1 2

1 0

0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 4

1 0 6

8 0

0 4

1 0

0 4

5 4

1 4

1 0.2 0.5 0.3 0.4 0.0 0.0 0.2 0.0 0.0 0.0 0.2 0.2 0.2 0.0 0.2 0.0 0

1 1

0 0

2 1

0 0

1 0

1 0

0 0

0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 5

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 1

4 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 4

1 2 8

9 2

0 12 6

0 0

6 6

7 2

4 1

0.2 0.6 0.4 0.4 0.1 0.0 0.6 0.3 0.0 0.0 0.3 0.3 0.3 0.1 0.2 0.0 0

0.0 10 0.5 52 2.5 7

0.3 5

0.2 5

0.2 0

0.0 79 3.7 MEAN WIND SPEED:

MISSING:

6.8 0

ARTIFICIAL ISLAND 10/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

ALL STABILITY CLASSES WIND SPEED GROUPS (MPH) 0.0-0.5 DIRECTION SUM PERCENT 0.6-3.5 SUM PERCENT 3.6-7.5 SUM PERCENT 7.6-12.5 SUM PERCENT

12. 6-18.5 SUM PERCENT 18.6-24.5 SUM PERCENT GE 24.6 SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 15 11 14 14 18 2

4 9

17 5

9 6

15 15 14 16 0.7 0.5 0.7 0.7

0. 9
0. 1 0.2 0.4 0.8 0.2 0.4 0.3 0.7 0.7 0.7 0.8 80 72 62 65 4 5 16 31 33 35 36 3 3 62 58 64 814 7 1
3. 8
3. 4 2.9 3.1 2.1 0.8 1.5 1.6 1.7 1.7 1.6 2.79 3.0 4.0 3.4 65 24 13 11 5

2 11 29 28 14 20 38 77 73 163 95 3.1 1.1 0.6 0.5 0.2

0. 1 0.5 1.4 1.3 0.7
0. 9 1.8 3.6 3.5 7.7 4.5 10 0

0 0

5 3

12 7

1 1 2

2 9

83 7 1 8 9 54 0.5 0.0 0.0 0.0 0.2 0.1 0.6 0.3 0.5 0.1

0. 1 0.4 3.9 3.4 4.2 2.6 4

0 0

0 0

0 1

4 0

0 1

2 1 3 9

1 5 3

0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.0 0.0 0.0 0.1 0.6 0.4 0.7 0.1 0

0 0

0 0

0 0

0 0

0 0

0 2

1 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 174 107 89 90 73 23 59 82 91 57 65 117 248 233 365 239 8.2 5.1 4.2 4.3 3.5

1. 1 2.8 3.9 4.3 2.7 3.1 5.5 11.7 11.0 17.3 11.3 0

0.0 184 8.7 847 40.1 668 31.6 358 17.0 52 2.5 3

0.1 2112 100.0 MISSING HOURS:

96 MEAN WIND SPEED:

8.6

ARTIFICIAL ISLAND 10/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

DIRECTION VS SPEED ONLY WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6'18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

  • 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 15 11 14 14 18 2

4 9

17 5

9 6

15 15 14 16 0.7 0.5 0.7 0.7

0. 9
0. 1 0.2 0.4 0.8 0.2 0.4 0.3 0.7 0.7 0.7 0.8 80 72 62 65 45 16 31 33 35 36 33 62 58 64 84 71 3.8 3.4 2.9 3.1 2.1 0.8 1.5 1.6 1.7 1.7 1.6 2.9 2.7 3.0 4.0 3.4 65 24 11 5

2 1 1 2 9 30 14 2 0 38 77 73 163 95 3.1 1.1 0.6 0.5 0.2

0. 1 0.5 1.4 1.4 0.7
0. 9 1.8 3.6 3.5 7.7 4.5 10 0

0 0

5 3

12 7

11 2

2 9

83 71 89 54 0.5 0.0 0.0 0.0 0.2 0.1 0.6 0.3 0.5

0. 1
0. 1 0.4 3.9 3.4 4.2 2.6 4

0 0

0 0

0 1

4 0

0 1

2 1 3 9

15 3

0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.0 0.0 0.0 0.1 0.6 0.4 0.7 0.1 0

0 0

0 0

0 0

0 0

0 0

0 2

1 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 174 107 89 90 73 23 59 82 93 57 65 117 248 233 365 239 8.2 5.1 4.2 4.3 3.5 1.1 2.8 3.9 4.4 2.7 3.1 5.5 11.7 11.0 17.3 11.3 0.0 184 8.7 847 40.1 670 31.7 358 16.9 52 2.5 3

0.1 2114 100.0 MISSING HOURS:

94 MEAN WIND SPEED:

8.6

ARTIFICIAL ISLAND 10/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS

-WIND: 150 FT DELTA T:

(300-33FT)

LAPSE RATE:

LE -1.9 DEG C/lOOM CLASS A WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0

0. D 0.0 0.0 0.0 0.0 0.0 0.0
0. 0 0.0 0.0 0

0 0

0 0

0 0

0 0

2 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 2

1 0

0 0

0 1

0 2

0 0.0

0. 0 0.0 0.0 0.0 0.0
0. 1 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0. 1 0.0 3

0 0

0 0

0 0

0 0

0 0

0 4

3 0

2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.1 0.0 0.1 1

0 0

0 0

0 0

0 0

0 0

0 2

4 4

2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.2 0.1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 1

2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 4

0 0

0 0

0 2

1 0

2 0

0 7

7 7

6 0.2 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.1 0.0 0.0 0.3 0.3 0.3 0.3 0

0.0 0

0.0 2

0.1 6

0.3 12 0.6 13 0.6 3

0.1 36 1.7 MEAN WIND SPEED:

17.0 MISSING:

14

ARTIFICIAL ISLAND 10/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE: -1.8 TO -1.7 DEG C/lOOM CLASS B WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 3

0.1 0

0.0 10 0.5 1

0.0 4

0.2 1

0.0 1

0.0 3

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 2

0.1 0

0.0 1

0.0 1

0.0 0

0.0 2

0.1 2

0.1 0

0.0 0

0.0 1

0.0 0

0.0 1

0.0 0

0.0 0

0.0 3

0.1 0

0.0 2

0.1 2

0.1 1

0.0 6

0.3 0

0.0 2

0.1 8

0.4 2

0.1 7

0.3 6

0.3 3

0.1 6

0.3 1

0.0 2

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 3

0.1 12 0.6 4

0.2 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 4

0.2 1

0.0 15 0.7 6

0.3 4

0.2 0

0.0 1

0.0 1

0.0 2

0.1 2

0.1 4

0.2 1

0.0 1

0.0 5

0.2 12 0.6 22 1.1 23 1.1 11 0.5 0

0.0 0

0.0 19 0.9 31 1.5 34 1.6 21 1.0 5

0.2 110 5.3 MEAN WIND SPEED:

13.8 MISSING:

15

ARTIFICIAL ISLAND 10/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE: -1.6 TO -1.5 DEG C/lOOM CLASS C WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0
0. 0 0.0
0. 0 0.0 0.0 0.0 1

0 0

0 0

0 0

0 1

0 3

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. I
0. 0 0.0 0.0
0. 0 0.0 I

2 5

0 0

0 0

0 0

3 3

3 4

2 3

4 0.0 0.1 0.2 0.0 0.0 0.0 0.0 0.0 0.0

0. I
0. 1
0. 1 0.2
0. I 0.1 0.2 5

9 5

0 1° 0

3 3

2 83 6

2 8

6 0.2 0.4 0.2 0.0 0.0 0.0

0. 1
0. 1
0. 1 0.0 0.0
0. 1 0.3
0. 1 0.4 0.3 2

1 0

0 0

0 0

0 1

3 0

2 1 0 2

2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0

0. 1 0.2 0.5
0. 1
0. 1 2

0 0

0 0

0 0

0 0

0 0

0 2

10 2

3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.5 0.1 0.1 0

0 0

0 0

0 0

0 0

0 0

0 0

4 3

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.1 0.0 11 12 10 0

1 0

3 3

4 7

7 8

16 28 1 8 I15 0.5 0.6 0.5 0.0

0. 0 0.0 0.1 0.1 0.2 0.3 0.3 0.4 0.8 1.4 0.9 0.7 0

0.0 5

0.2 30 1.5 55 2.7 27 1.3 19 0.9 7

0.3 143 6.9 MEAN WIND SPEED:

12.4 MISSING:

8

ARTIFICIAL ISLAND 10/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T:

(300-33FT)

LAPSE RATE: -1.4 TO -0.5 DEG C/lOOM CLASS D WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5

18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 1

3 2

0 2

1 1

2 5

2 0

2 2

1 1

2 0.0 0.1 0.1 0.0

0. 1 0.0 0.0
0. 1 0.2
0. 1 0.0
0. 1
0. 1 0.0 0.0
0. 1 10 9

20 7

15 6

5 14 7

9 7

5 9

1 0 6

13 0.5 0.4 1.0 0.3 0.7 0.3 0.2 0.7 0.3 0.4 0.3 0.2 0.4 0.5 0.3 0.6 1 3 6

1 2 1 5 1 3 2

1 2 1 0 10 1 8 1 7 12 17 2 7 1 0 1 0

0. 6
0. 3
0. 6
0. 7
0. 6
0. 1
0. 6
0. 5
0. 5
0. 9
0. 8
0. 6
0. 8 1.3
0. 5
0. 5 15 3

3 3

0 0

5 16 10 6

1 6

47 39 57 9

0.7 0.1 0.1

0. 1 0.0 0.0 0.2 0.8 0.5 0.3
0. 0 0.3 2.3
1. 9 2.8 0.4 1

0 0

0 2

0 1

2 0

0 1

1 20 53 39 14 0.0 0.0 0.0 0.0 0.1 0.0 0.0

0. 1 0.0 0.0 0.0 0.0 1.0 2.6 1.9 0.7 0

0 0

0 0

2 0

0 0

0 1

0 7

17 11 4

0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.3 0.8 0.5 0.2 40 21 37 25 32 11 24 44 32 35 27 26 102 147 124 52 1.9 1.0 1.8 1.2 1.5 0.5 1.2 2.1 1.5 1.7 1.3 1.3 4.9 7.1 6.0 2.5 0

0.0 27 1.3 152 7.4 204 9.9 220 10.6 134 6.5 42 2.0 779 37.7 MEAN WIND SPEED:

13.2 MISSING:

13

ARTIFICIAL ISLAND 10/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT(

LAPSE RATE: -0.4 TO 1.5 DEG C/lOOM CLASS E WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1

1 0

2 2

2 1

1 2

0 2

2 2

3 4

5 0.0 0.0 0.0 0.1 0.1

0. 1 0.0 0.0
0. 1
0. 0 0.1
0. 1
0. 1 0.1 0.2 0.2 5

6 8

1 5 9

1 3 7

5 8

6 3

3 1 0 9

1 1 6

0.2 0.3 0.4 0.7 0.4 0.6 0.3 0.2 0.4 0.3 0.1 0.1 0.5 0.4 0.5 0.3 24 21 20 14 16 4

8 6

2 10 13 19 26 32 44 16 1.2 1.0 1.0 0.7 0.8 0.2 0.4 0.3 0.1 0.5 0.6

0. 9 1.3 1.5 2.1 0.8 4 7 1 5 4

1 5

1 1

3 0

3 2

4 20 1 6 58 20 2.3 1

0.7 0

0.2 0

0.0 0

0.2 2

0.0 1

0.0 9

0.1 3

0.0 0

0.1 0

0.1 3

0.2 0

1.0 5

0.8 1

2.8 4

1.0 5

0.0 0.0 0.0 0.0

0. 1 0.0 0.4 0.1 0.0 0.0 0.1 0.0 0.2 0.0 0.2 0.2 0

0 0

0 0

0 5

0 0

1 3

1 1

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 78 43 32 32 34 21 31 18 12 20 26 29 64 61 121 52 3.8 2.1 1.5 1.5 1.6 1.0 1.5 0.9 0.6 1.0 1.3 1.4 3.1 2.9 5.9 2.5 0

0.0 30 1.5 124 6.0 275 13.3 200 9.7 34 1.6 11 0.5 674 32.6 MEAN WIND SPEED:

11.2 MISSING:

64

ARTIFICIAL ISLAND 10/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE:

1.6 TO 4.0 DEG C/100M CLASS F WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 3

2 2

0 1

0 0

0 1° 1

0 0

1 1

0.0 0.0

0. 1
0. 1
0. 1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0. 0
0. 0 0.0 3

2 1

3 7

2 1

4 5

5 1

4 5

5 7

5 0.1

0. 1 0.0
0. 1 0.3 0.1 0.0 0.2 0.2 0.2 0.0 0.2 0.2 0.2 0.3 0.2 6

6

'11 5

12 9

5 0

2 2

a 3

23 7

8 10 0.3 0.3 0.5 0.2 0.6 0.4 0.2 0.0

0. 1
0. 1 0.4
0. 1 1.1 0.3 0.4 0.5 SUM PERCENT 10 0.5 0

0.0 5

0.2 3

0.1 1

0.0 2

0.1 0

0.0 0

0.0 0

0.0 3

0.1 2

0.1 4

0.2 2

0.1 2

0.1 4

0.2 4

0.2 SUM PERCENT SUM PERCENT 0

0 0

0 0

0 1

0 0

0 1

1 7

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.3 0.0 0.0 0.0 0

0 0

0 0

0 4

2 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 19 8

20 13 22 13 12 6

7 10 13 13 37 14 20 20

0. 9 0.4 1.0 0.6 1.1 0.6 0.6 0.3 0.3 0.5 0.6 0.6 1.8 0.7 1.0 1.0 0

0.0 12 0.6 60 2.9 117 5.7 42 2.0 10 0.5 6

0.3 247 11.9 MEAN WIND SPEED:

10.2 MISSING:

24

ARTIFICIAL ISLAND 10/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T:

(300-33FT)

LAPSE RATE:

GT 4.0 DEG C/1OOM CLASS G WIND SPEED GROUPS (MPH) 0.0-0.5 DIRECTION SUM PERCENT 0.6-3.5 SUM PERCENT 3.6-7.5 SUM PERCENT 7.6-12.5 SUM PERCENT 12.6-'18.5 SUM PERCENT 18.6-24.5 SUM PERCENT GE 24.6 SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1

3 5

1 3

1 0

0 1

0 1

1 0

0 4

1 0.0 0.1 0.2 0.0

0. 1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.0 1

2 2

2 7

1 0

1 2

0 1

3 3

4 2

0.0 0.1 0.1 0.1 0.3 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.1 0.1 0.2 0.1 0

0 3

1 1

0 1

1 0

0 1

0 3

1 1

0 0.0 0.0

0. 1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0

0 0

0 0

0 1

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

9 1

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 3

5 140 4

1 1 2

2 1 1 4

0 3

2 6

4 9

3 0.1 0.2 0.5 0.2 0.5 0.1 0.1 0.5 0.2 0.0 0.1 0.1 0.3 0.2 0.4 0.1 0

0.0 0.0 22 1.1 32 1.5 13 0.6 1

0.0 10 0.5 79 3.8 MEAN WIND SPEED:

12.3 MISSING:

0

ARTIFICIAL ISLAND 10/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

ALL STABILITY CLASSES WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18. 5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 4

0.2 4

0.2 5

0.2 4

0.2 6

0.3 3

0.1 3

0.1 3

0.1 8

0.4 2

0.1 6

0.3 5

0.2 4

0.2 4

0.2 6

0.3 8

0.4 23 1.1 49 2.4 87 4.2 7

0.3 0

0.0 23 1.1 48 2.3 20 1.0 0

0.0 0

0.0 40 1.9 53 2.6 15 0.7 0

0.0 0

0.0 26 1.3 36 1.7 8

0.4 0

0.0 0

0.0 34 1.6 50 2.4 7

0.3 4

0.2 0

0.0 22 1.1 17 0.8 3

0.1 1

0.0 2

0.1 13 0.6 32 1.5 7

0.3 12 0.6 9

0.4 24 1.2 22 1.1 20 1.0 5

0.2 11 0.5 23 1.1 20 1.0 11 0.5 0

0.0 1

0.0 25 1.2 32 1.5 15 0.7 0

0.0 1

0.0 16 0.8 40 1.9 6

0.3 5

0.2 4

0.2 19 0.9 38 1.8 18 0.9 2

0.1 1

0.0 30 1.5 77 3.7 86 4.2 39 1.9 8

0.4 26 1.3 73 3.5 79 3.8 80 3.9 21 1.0 33 1.6 83 4.0 128 6.2 53 2.6 19 0.9 32 1.5 50 2.4 38 1.8 24 1.2 7

0.3 409 19.8 720 34.8 548 26.5 232 11.2 84 4.1 170 8.2 95 4.6 113 5.5 74 3.6 101 4.9 48 2.3 76 3.7 85 4.1 63 3.0 75 3.6 77 3.7 83 4.0 244 11.8 283 13.7 322 15.6 159 7.7 2068 100.0 0

0.0 75 3.6 MISSING HOURS:

140 MEAN WIND SPEED:

12.2

ARTIFICIAL ISLAND 10/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

DIRECTION VS SPEED ONLY WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 4

4 5

4 6

3 3

3 8

2 6

5 4

4 6

8 0.2 0.2 0.2 0.2 0.3

0. 1
0. 1
0. 1 0.4 0.1 0.3 0.2 0.2 0.2 0.3 0.4 23 23 4 0 26 34 22 13 2 4 23 25 1 6 1 9 30 26 33 32 1.1 1.1
1. 9 1.3 1.6 1.1 0.6 1.2 1.1 1.2 0.8
0. 9 1.4 1.3 1.6 1.5 49 48 53 36 50 17 32 22 21 32 40 38 77 73 83 50 2.4 2.3 2.6 1.7 2.4 0.8 1.5
1. 1 1.0 1.5
1. 9 1.8 3.7 3.5 4.0 2.4 87 20 15 8

7 3

7 20 1 2 1 5 6

1 8 86 7 9 128 38 4.2 1.0 0.7 0.4 0.3

0. 1 0.3 1.0 0.6 0.7 0.3
0. 9 4.2 3.8 6.2 1.8 7

0 0

0 4

1 12 5

0 0

5 2

39 80 53 24 0.3 0.0 0.0 0.0 0.2 0.0 0.6 0.2 0.0 0.0 0.2 0.1

1. 9 3.9 2.6 1.2 0

0 0

0 D

2 9

11 1

1 4

1 8

21 1 9 7

0.0 0.0 0.0 0.0 0.0 0.1 0.4 0.5 0.0 0.0 0.2 0.0 0.4 1.0 0.9 0.3 170 95 113 74 101 48 76 85 65 75 77 83 244 283 322 159 8.2 4.6 5.5 3.6 4.9 2.3 3.7 4.1 3.1 3.6 3.7 4.0 11.8 13.7 15.6 7.7 0

0.0 75 3.6 409 19.8 721 34.8 549 26.5 232 11.2 84 4.1 2070 100.0 MISSING HOURS:

138 MEAN WIND SPEED:

12.2

ARTIFICIAL ISLAND 10/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE:

LE -1.9 DEG C/100M CLASS A WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18. 5
18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

1 1

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0

  • 0 0

0 0

2 1

0 0

0 0

2 0

1 1

0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 2

1 3

4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.1 0.2 0

0 0

0 0

0 0

0 0

0 0

0 6

4 10 3

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.3 0.2 0.5 0.1 1

0 0

0 0

0 0

0 0

0 0

0 0

0 4

3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.1 1

0 0

0 0

0 2

1 0

1 1

0 10 5

18 1 1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.5 0.2 0.8 0.5 0

0.0 0

0.0 2

0.1 0.3 10 0.5 23 1.0 8

0.4 50 2.3 MEAN WIND SPEED:

19.1 MISSING:

0

ARTIFICIAL ISLAND 10/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE: -1.8 TO -1.7 DEG C/1OOM CLASS B WIND SPEED GROUPS (MPH) 0.0-0.5 DIRECTION SUM PERCENT 0.6-3.5 SUM PERCENT 3.6-7.5 SUM PERCENT 7.6-12.5 SUM PERCENT 12.6-18.5 SUM PERCENT 18.6-24.5 SUM PERCENT GE 24.6 SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0
0. 0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0

0. 0 0.0
0. 0 0.0
0. 0 0.0 0.0 0.0 0.0 0.0
0. 0 0.0 0.0 0.0 2

0 0

0 0

0 0

1 2

0 12 3

0 1

0. 1
0. 0 0.0 0.0 0.0 0.0 0.0 0.0
0. 1 0.0
0. 0
0. 1 0.1
0. 1
0. 0 0.0 3

0.1 4

0.2 0

3 0.1 0

0.0 0

0 0.0 0

0.0 0

0 0.0 0

0.0 0

0 0.0 1

0.0 0

0 0.0 1

0.0 0

2 0.1 0

0.0 0

1 0.0 0

0.0 0

2 0.1 0

0.0 0

1 0.0 0

0.0 0

0 0.0 0

0.0 0

1 0.0 2

0.1 2

1 0.0 4

0.2 11 3

0.1 4

0.2 10 12 0.5 5

0.2 6

5 0.2 11 0.5 6

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 1 0.5 0.5 0.3 0.3 1

0 0

0 0

0 0

0 0

0 0

0 0

0 7

2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.3 0.1 10 3

0 0

1 1

2 2

4 1

1 7

1 8 20 30 25 0.5

0. 1 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.0 0.0 0.3
0. 8 0.9 1.4 1.1 0

0.0 MEAN WIND SPEED:

15.5 MISSING:

0 0

0.0 14 0.6 34 1.5 32 1.5 35 1.6 10 0.5 125 5.7

ARTIFICIAL ISLAND 10/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE: -1.6 TO -1.5 DEG C/1OOM CLASS C WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-1B. 5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0 0.0
0. 0
0. 0
0. 0 0.0 0.0 0.0 0.0 0

1 0

0 0

0 0

1 0

1 0

I 1

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 1

4 1

0 0

0 0

1 0

2 3

5 2

4 4

0.0 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.1 0.2 0.2 2

.8

  • 2 0

1 0

3 3

1 2

1 6

6 1

8 12 0.1 0.4

0. 1 0.0 0.0 0.0 O.1
0. 1 0.0
0. 1 0.0 0.3 0.3 0.0 0.4 0.5 0

0 0

0 0

0 0

0 2

2 0

2 6

2 6

3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.0 0.1 0.3 0.1 0.3 0.1 0

0 0

0 0

0 0

0 0

0 0

1 9

6 4

3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.4 0.3 0.2 0.1 0

0 0

0 0

0 0

0 0

0 0

0 4

4 5

3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.2 0.2 0.1 3

13 3

0 1

0 3

5 3

6 3

13 31 15 27 25 0.1 0.6 0.1 0.0 0.0 0.0 0.1 0.2 0.1 0.3 0.1 0.6 1.4 0.7 1.2 1.1 0

0.0 5

0.2 28 1.3 56 2.6 23 1.0 23 1.0 16 0.7 151 6.9 MEAN WIND SPEED:

13.6 MISSING:

0

ARTIFICIAL ISLAND 10/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE: -1.4 TO -0.5 DEG C/1OOM CLASS D WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

0. 0 0.0
0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 4

4 2

2 0

0 6

4 3

2 3

1 2

2 1

1 0.2 0.2 0.1 0.1 0.0 0.0 0.3 0.2

0. 1 0.1 0.1 0.0 0.1 0.1 0.0 0.0 1 0

-7 9

9 1 2 6

6 5

5 6

4 5

9 1 2 6

6 0.5 0.3 0.4 0.4 0.5 0.3 0.3 0.2 0.2 0.3 0.2 0.2 0.4 0.5 0.3 0.3 9

7 8

11 14 4

8 11 8

13 17 12 15 19 3

0.4 0.3 0.4 0.5 0.6 0.2 0.4 0.5 0.4 0.6 0.8 0.5 0.7

0. 9
0. 1 7

3 3

6 1

2 7

1 6 1 1 1 3 1

7 57 36 38 0.3 0.1 0.1 0.3 0.0

0. 1 0.3 0.7 0.5 0.6 0.0 0.3 2.6 1.6 1.7 1

0 0

0 2

0 3

4 0

1 0

0 39 4 2 36 8

0.0 0.0 0.0 0.0 0.1 0.0 0.1 0.2 0.0 0.0 0.0 0.0 1.8 1.9 1.6 0.4 0

0 0

0 1

1 0

0 0

1 0

1 29 25 26 12 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1.3 1.1 1.2 0.5 31 21 22 28 30 13 30 40 27 36 25 26 151 136 110 58 1.4 1.0 1.0 1.3 1.4 0.6 1.4 1.8 1.2 1.6 1.1 1.2 6.9 6.2 5.0 2.6 17 0.8 14 0.6 0

0.0 37 1.7 117 5.3 176 8.0 222 10.1 136 6.2 96 4.4 784 35.7 MEAN WIND SPEED:

14.8 MISSING:

8

ARTIFICIAL ISLAND 10/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE: -0.4 TO 1.5 DEG C/1OOM CLASS E WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1

1 2

2 1

2 4

0 1

4 2

2 0

2 2

0 0.0 0.0 0.1 0.1 0.0 0.1 0.2 0.0 0.0 0.2

0. 1 0.1 0.0 0.1 0.1*

0.0 5

2 7

5 10 7

8 1

5 6

5 6

3 9

6 7

0.2 0.1 0.3 0.2 0.5 0.3 0.4 0.0 0.2 0.3 0.2 0.3 0.1 0.4 0.3 0.3 10 7

8 11 23 4

5 6

2 4

6 10 13 21 22 8

0.5 0.3 0.4 0.5 1.0 0.2 0.2 0.3

0. 1 0.2 0.3 0.5 0.6 1.0 1.0 0.4 40 21 6

1 6

3 4

2 7

11 20 28 25 80 35 1.8 1.0 0.3 0.0 0.3 0.1 0.2 0.2 0.1 0.3 0.5 0.9 1.3 1.1 3.6 1.6 21 0

0 0

2 0

4 3

1 1

6 4

14 4

49 19 1.0 0.0 0.0 0.0 0.1 0.0 0.2 0.1 0.0 0.0 0.3 0.2 0.6 0.2 2.2

0. 9 5

0 0

0 2

1 1 1 0

0 1

3 2

2 0

2 6

0.2 0.0 0.0 0.0 0.1 0.0 0.5 0.0 0.0 0.0 0.1 0.1 0.1 0.0 0.1 0.3 82 31 23 19 44 17 36 14 11 23 33 44 60 61 161 75 3.7 1.4 1.0

0. 9 2.0 0.8 1.6 0.6 0.5 1.0 1.5 2.0 2.7 2.8 7.3 3.4 0

0.0 26 1.2 92 4.2 160 7.3 293 13.4 128 5.8 35 1.6 734 33.5 MEAN WIND SPEED:

14.3 MISSING:

4

ARTIFICIAL ISLAND 10/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE:

1.6 TO 4.0 DEG C/1OOM CLASS F WIND SPEED bROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 1

0 2

1 0

0 2

0 0

01 0

0 0.0 0.0 0.0 0.0

0. 1 0.0
0. 0
0. 0
0. 1 0.0 0.0 0.0
0. 0
0. 0 0.0 0.0 2

1 1

2 5

6 3

4 2

1 3

0 3

2 2

0.1 0.0 0.0

0. 1 0.2 0.3 0.1 0.2 0.1 0.0
0. 1 0.0
0. 1
0. 1
0. 1 0.0 7

3

' 2 3

3 8

3 1

2 1

0 5

11 10 6

9 0.3 0.1

0. 1
0. 1
0. 1 0.4
0. 1 0.0
0. 1 0.0
0. 0 0.2
0. 5 0.5 0.3 0.4 9

7 5

2 7

5 2

0 0

1 6

9 6

5 1 1 26 0.4 0.3 0.2

0. 1 0.3 0.2 0.1
0. 0 0.0 0.0 0.3 0.4 0.3 0.2 0.5 1.2 2

2 5

0 1

1 0

1 0

3 6

7 4

0 3

4 0.1 0.1 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.3 0.2 0.0 0.1 0.2 0

0 0

0 0

0 1

4 1

0 0

2 3

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.0 0.0 0.0 0.1 0.1 0.0 0.0 0.0 20 13 14 7

18 21 9

10 7

6 16 23 27 18 22 40

0. 9 0.6 0.6 0.3
0. 8 1.0 0.4 0.5 0.3 0.3 0.7 1.0 1.2 0.8 1.0 1.8 0

0.0 8

0.4 38 1.7 74 3.4 101 4.6 39 1.8 11 0.5 271 12.4 MEAN WIND SPEED:

13.6 MISSING:

0

ARTIFICIAL ISLAND 10/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE:

GT 4.0 DEG C/1OOM CLASS G WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5

18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 1

1 2

2 2

1 0

0 0

1 0

0 0

0 1

0.0 0.0 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

1

.3 3

3 2

1 0

1 0

2 1

2 3

0 0.0 0.0 0.1 0.1 0.1 0.1

0. 0 0.0 0.0 0.0 0.0
0. 1 0.0 0.1 0.1 0.0 1

2 0

0 2

5 0

1 0

1 0

2 2

3 4

2 0.0 0.1 0.0 0.0 0.1 0.2 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.1 0

1 2

0 0

0 0

1 1

0 2

0 3

0 0

0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.1 0.0 0.0 0.0 0

0 0

0 0

0 0

7 3

0 0

0 0

0 0

0 0.0 0.0

0. 0
0. 0
0. 0 0.0
0. 0
0. 3
0. 1
0. 0 0.0 0.0 0.0 0.0 0.0 0.0 2

5 7

5 7

8 1

9 4

3 3

4 6

5 7

3 0.1 0.2 0.3 0.2 0.3 0.4 0.0 0.4 0.2 0.1 0.1 0.2 0.3 0.2 0.3 0.1 0

0.0 0

0.0 12 0.5 22 1.0 25 1.1 10 0.5 10 0.5 79 3.6 MEAN WIND SPEED:

15.5 MISSING:

0

ARTIFICIAL ISLAND 10/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

ALL STABILITY CLASSES WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5

3. 6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 5

0.2 21 1.0 31 1.4 61 2.8 0

0.0 6

0.3 15 0.7 29 1.3 33 1.5 0

0.0 5

0.2 20 0.9 23 1.0 14 0.6 0

0.0 4

0.2 18 0.8 28 1.3 9

0.4 0

0.0 3

0.1 29 1.3 44 2.0 17 0.8 0

0.0 3

0.1 20 0.9 18 0.8 16 0.7 0

0.0 10 0.5 17 0.8 24 1.1 13 0.6 0

0.0 5

0.2 12 0.5 23 1.0 21 1.0 0

0.0 6

0.3 14 0.6 15 0.7 15 0.7 0

0.0 7

0.3 16 0.7 22 1.0 24 1.1 0

0.0 6

0.3 17 0.8 24 1.1 18 0.8 0

0.0 4

0.2 16 0.7 36 1.6 42 1.9 0

0.0 3

0.1 22 1.0 49 2.2 105 4.8 0

0.0 5

0.2 28 1.3 56 2.6 76 3.5 0

0.0 3

0.1 18 0.8 55 2.5 147 6.7 0

0.0 1

0.0 20 0.9 52 2.4 95 4.3 0

0.0 76 3.5 303 13.8 529 24.1 706 32.2 24 1.1 3

0.1 7

0.3 0

0.0 5

0.2 1

0.0 7

0.3 9

0.4 2

0.1 5

0.2 14 0.6 14 0.6 86 3.9 66 3.0 108 4.9 43 2.0 394 18.0 7

0.3 0

0.0 0

0.0 0

0.0 3

0.1 2

0.1 12 0.5 11 0.5 4

0.2 2

0.1 3

0.1 5

0.2 38 1.7 29 1.3 44 2.0 26 1.2 149 6.8 86 3.9 69 3.1 59 2.7 101 4.6 60 2.7 83 3.8 81 3.7 56 2.6 76 3.5 82 3.7 117 5.3 303 13.8 260 11.9 375 17.1 237 10.8 186 8.5 2194 100.0 MISSING HOURS:

14 MEAN WIND SPEED:

14.5

ARTIFICIAL ISLAND 10/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

DIRECTION VS SPEED ONLY WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 5

0.2 6

0.3 5

0.2 4

0.2 3

0.1 3

0.1 10 0.5 5

0.2 6

0.3 7

0.3 6

0.3 4

0.2 3

0.1 5

0.2 3

0.1 1

0.0 21 1.0 31 1.4 61 2.8 15 0.7 29 1.3 33 1.5 20 0.9

'23 1.0 14 0.6 18 0.8 28 1.3 9

0.4 29 1.3 44 2.0 17 0.8 20 0.9 18 0.8 16 0.7 17 0.8 24 1.1 13 0.6 12 0.5 23 1.0 21 1.0 14 0.6 16 0.7 15 0.7 16 0.7 22 1.0 24 1.1 17 0.8 24 1.1 18 0.8 16 0.7 36 1.6 42 1.9 22 1.0 49 2.2 105 4.8 28 1.3 56 2.6 76 3.5 18 0.8 55 2.5 147 6.7 20 0.9 52 2.4 95 4.3 24 1.1 3

0.1 7

0.3 0

0.0 5

0.2 1

0.0 7

0.3 9

0.4 2

0.1 5

0.2 14 0.6 14 0.6 86 3.9 66 3.0 108 4.9 43 2.0 7

0.3 0

0.0 0

0.0 0

0.0 3

0.1 2

0.1 12 0.5 11 0.5 4

0.2 2

0.1 3

0.1 5

0.2 38 1.7 29 1.3 44 2.0 26 1.2 149 6.8 86 3.9 69 3.1 59 2.7 101 4.6 60 2.7 83 3.8 81 3.7 57 2.6 76 3.5 82 3.7 117 5.3 303 13.8 260 11.8 375 17.1 237 10.8 0

0.0 76 3.5 303 13.8 530 24.1 706 32.2 394 17.9 186 8.5 2195 100.0 MISSING HOURS:

13 MEAN WIND SPEED:

14.5

Artificial Island Meteorological Monitoring System Joint Frequencies July - Sept 2001

ARTIFICIAL ISLAND 7/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE:

LE -1.9 DEG C/1OOM CLASS A WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18. 5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0

0. 0
0. 0 0.0
0. 0
0. 0
0. 0
0. 0 0.0 0.0
0. 0 0.0
0. 0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 0.0
0. 0 0.0 0.0
0. 0
0. 0 0.0 0.0 0.0 0

0 0

0 0

0 0

7 5

6 2

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.2 O.1 0.1
0. 0
0. 0
0. 0 0.0 0.0 0.0 0

0 1

1 0

0 3

4 0

7 2

5 2

0 3

2 0.0 0.0 0.0 0.0

0. 0 0.0 0.1
0. 1 0.0 0.2 0.0 0.1 0.0 0.0 0.1 0.0 0

0 0

0 0

0 0

3 0

0 0

0 9

2 1 3 1 0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.2 0.0 0.3 0.2 2

0 0

0 0

0 0

0 0

0 0

0 0

0 1

1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 2

0 1

1 0

0 3

14 5

13 4

5 12 3

17 1 3 0.0 0.0 0.0 0.0 o0:0 0.0

0. 1 0.3 0.1 0.3 0.1 0.1 0.3
0. 1 0.4 0.3 0

0.0 0

0.0 22 0.5 30 0.7 37 0.9 0.1 0

0.0 93 2.2 MEAN WIND SPEED:

11.3 MISSING:

0

ARTIFICIAL ISLAND 7/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY Cl.ASS WIND:

30 FT DELTA T: (300-33FT)

LAPSE RATE: -1.8 TO -1.7 DEG C/1OOM CLASS B WIND SPEE[) GROUPS (MPIJ) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18. 5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

0. 0 0.0 0.0 0.0 0.0
0. 0
0. 0
0. 0 0.0 0.0
0. 0 0.0 0.0 0.0
0. 0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0

0. 0 0.0
0. 0 0.0 0.0 0.0
0. 0
0. 0 0.0
0. 0
0. 0
0. 0
0. 0 0.0.

0.0 4

4 0

0 0

2 6

1 1 5

4 8

5 3

7 8

0.1

0. 1
0. 0 0.0 0.0
0. 0
0. 0
0. 1 0.3
0. 1
0. 1 0.2
0. 1
0. 1 0.2 0.2 10 5

1 0

2 2

7 5

3 3

10 4

5 12 16 0.2

0. 1
0. 0
0. 0
0. 0
0. 0
0. 0 0.2
0. 1
0. 1
0. 1 0.2
0. 1
0. 1 0.3 0.4 1

0 0

0 0

0 2

5 0

0 0

0 1 5 1 0 1 1 9

0.0 0.0 0.0 0.0 0.0 0.0

0. 0
0. 1 0.0
0. 0
0. 0 0.0 0.3 0.2 0.3 0.2 1

0 0

0 0

0 0

0 0

0 0

0 0

0 4

2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 16 9

2 0

2 2

6 18 1 6 9

7 1 8 2 4 1 8 34 35 0.4 0.2 0.0 0.0 0.0 0.0

0. 1 0.4 0.4 0.2 0.2 0.4 0.6 0.4 0.8 0.8 0

0.0 1

0.0 68 1.6 87 2.0 53 1.2 7

0.2 0

0.0 216 5.0 MEAN WIND SPEED:

10.0 MISSING:

3

ARTIFICIAL ISLAND 7/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE: -1.6 TO -1.5 DEG C/1OOM CLASS C WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 0.0 2

0 0

0 0

1 0

0 5

0 0

0 0

1 2

0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0
0. 0
0. 1 0.0 0.0 0.0
0. 0 0.0 0.0 0.0 18 9

2 0

3 0

4 11 10 11 1 1 8

8 7

10 15 0.4 0.2 0.0 0.0

0. I 0.0 0.1 0.3 0.2 0.3 0.3 0.2 0.2 0.2 0.2 0.3 16 14 2

1 2

0 3

12 6

4 6

11 11 6

15 16 0.4 0.3 0.0 0.0 0.0 0.0

0. I 0.3
0. 1
0. 1
0. 1 0.3 0.3 0.1 0.3 0.4 2

1 0

0 0

0 0

4 2

1 1

2 1 2 6

1 1 7

0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 1 0.0 0.0 0.0 0.0 0.3 0.1 0.3 0.2 1

0 0

0 0

0 0

0 0

0 0

0 1

2 3

0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0

0 0

0 0

0 0

0 0

0 0

0 1

0 0

0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 39 24 4

1 5

1 7

27 23 16 18 21 33 22 41 38

0. 9 0.6 0.1 0.0 0.1 0.0 0.2 0.6 0.5 0.4 0.4 0.5 0.8 0.5 1.0
0. 9 0

0.0 11 0.3 127 2.9 125 2.9 49 1.1 7

0.2 1

0.0 320 7.4 MEAN WIND SPEED:

8.8 MISSING

4

ARTIFICIAL ISLAND 7/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY Cl.ASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE: -1.4 TO -0.5 DEG C/1OOM CLASS D WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18. 5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

0. 0
0. 0 0.0
0. 0 0.0
0. 0
0. 0
0. 0 0.0
0. 0 0.0
0. 0
0. 0 0.0
0. 0 0.0 9

10 7

3 6

2 4

6 11 7

7 5

3 8

5 16 0.2 0.2 0.2

0. 1
0. 1
0. 0
0. 1
0. 1 0.3 0.2 0.2
0. 1
0. 1 0.2
0. 1 0.4 61 40 57 37 29 20 1 9 44 51 52 31 31 34 36 24 37 1.4
0. 9 1.3
0. 9 0.7 0.5 0.4
1. 0 1.2 1.2 0.7 0.7 0.8 0.8 0.6
0. 9 34 51 36 24 9

9 39 72 93 59 26 30 64 56 53 40 0.8 1.2 0.8 0.6 0.2 0.2

0. 9 1.7 2.2 1.4 0.6 0.7 1.5 1.3 1.2
0. 9 10 13 2

4 1

4 43 27 7

2 2

52 60 53 22 0.2 0.3

0. 0
0. 0 0.1 0.0
0. 1
1. 0 0.6 0.2 0.0 0.0 1.2 1.4 1.2 0.5 0

0 0

0 0

0 0

3 1

0 0

2 1 2 7

7 0

0. 0 0.0 0.0 0.0
0. 0 0.0
0. 0
0. 1 0.0 0.0
0. 0 0.0 0.3 0.2 0.2 0.0 0

0 0

0 0

0 0

0 0

0 0

0 1

1 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 114 114 102 65 48 32 66 168 183 125 66 70 166 168 142 115 2.6 2.6 2.4 1.5 1.1 0.7 1.5 3.9 4.2 2.9 1.5 1.6 3.8 3.9 3.3 2.7 0

0.0 109 2.5 603 14.0 695 16.1 303 7.0 32 0.7 2

0.0 1744 40.4 MEAN WIND SPEED:

9.0 MISSING

54

ARTIFICIAL ISLAND 7/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE: -0.4 TO 1.5 DEG C/1OOM CLASS E WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

1. 6-1 2. 5 12.6'18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0

0. 0
0. 0
0. 0
0. 0 0.0 0.0
0. 0 0.0 0.0 0.0
0. 0 0.0 0.0 18 10 22 18 13 3

3 3

4 5

1 6

1 6 12 11 10 0.4 0.2 0.5 0.4 0.3 0. 1 0. 1 0.1 0. 1 0. 1

0. 0
0. 1 0.4 0.3 0.3 0.2 77 48 34 52 34 24 20 18 20 30 41 41 41 46 85 64 1.8
1. 1 0.8 1.2 0.8 0.6 0.5 0.4 0.5 0.7 1.0 1.0
1. 0 1.1 2.0 1.5 94 22 16 6

3 4

7 21 28 45 40 27 21 39 109 49 2.2 0.5 0.4

0. 1
0. 1
0. 1 0.2 0.5 0.6 1.0
0. 9 0.6 0.5
0. 9 2.5 1.1 7

4 1

0 2

2 3

3 5

4 2

3 8

3 6

8 0.2

0. 1 0.0 0.0 0.0 0.0
0. 1 0.1 0.1
0. 1 0.0 0.1 0.2
0. 1 0.1 0.2 0

0 0

0 0

0 0

0 0

0 1

0 0

0 0

1

0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 O..

0 196 84 73 76 52 33 33 45 57 84 85 77 86 100 211 132 4.5

1. 9 1.7 1.8 1.2 0.8 0.8 1.0 1.3 1.9 2.0 1.8 2.0 2.3 4.9 3.1 0

0.0 155 3.6 675 15.7 531 12.3 61 1.4 2

0.0 0

0.0 1424 33.0 MEAN WIND SPEED:

7.1 MISSING

23

ARTIFICIAL. ISLAND 7/00-12/00 JOINTr DISTRIBUTION Of WIND DIRECTION AND SPEED BY ATM(Sl'ilERIC STABILITY ClASS WINI):

30 FT DEL.TA T:

(300-33FT)

LAPSE RATE:

1.6 TO 4.0 DEG C/1OOM CLASS F WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0

0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0 0.0 0.0
0. 0 5

3 9

4 4

1 4

6 2

6 6

5 5

0. 1
0. 1 0.2
0. 1 0.1 0.0
0. 0
0. 0
0. 1
0. 0
0. 1 0.0
0. 1
0. 1
0. 1
0. 1 31 30 33 25 21 5

2 5

6 8

13 16 14 16 24 29 0.7 0.7 0.8 0.6 0.5

0. I 0.0
0. I
0. I 0.2 0.3 0.4 0.3 0.4 0.6 0.7 17 3

2 0

0 0

0 7

2 9

2 2

13 16 0.4

0. 1 0.0
0. 0 0.0 0.0 0.0
0. 0
0. 0 0.2
0. 0 0.2 0.0
0. 0 0.3 0.4 0

0 0

0 0

0 3

0 3

0 0

7 0

0 0

0

0. 0
0. 0 0.0 0.0
0. 0
0. 0
0. I 0.0
0. 1 0.0
0. 0 0.2 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 53 36 44 29 25 6

7 6

1 4 1 6 21 34 22 24 42 50 1.2 0.8

1. 0 0.7 0.6
0. 1 0.2
0. 1 0.3 0.4 0.5 0.8 0.5 0.6 1.0 1.2 0

0.0 63 1.5 278 6.4 75 1.7 13 0.3 0

0.0 0.0 429 9.9 MEAN WIND SPEED:

6.0 MISSING

17

ARTIFICIAL ISLAND 7/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE:

GT 4.0 DEG C/1OOM CLASS G WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12. 5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0
0. 0
0. 0 0.0 0.0 0.0 0.0 0

1 1

1 2

0 0

0 0

0 1

2 1

0 0

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0
0. 0
0. 0.

0.0 5

1 4 9

8 0

0 4

1 0

0 4

5 4

4 1

0.1 0.3 0.2 0.2

0. 0 0.0
0. 1 0.0 0.0 0.0
0. 1
0. 1
0. 1 0.0
0. 1 0.0 0

1 1

0 0

0 2

1 0

0 1

0 1

0 0

0 0.0 0.0

0. 0
0. 0
0. 0 0.0
0. 0
0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 5

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0

0. 1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 1

4 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 5

16 11 9

2 0

12 6

0 0

6 6

7 2

4 1

0.1 0.4 0.3 0.2 0.0 0.0 0.3 0.1 0.0 0.0 0.1 0.1 0.2 0.0 0.1 0.0 0

0.0 10 0.2 60 1.4 7

0.2 0.1 5

0.1 0

0.0 87 2.0 MEAN WIND SPEED:

6.7 MISSING

0

ARTIFICIAL ISLAND 7/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T:

(300-33FT)

ALL STABILITY CLASSES WIND SPEED GROUPS (MPH) 0.0-0. 5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0
0. 0 0.0 0.0
0. 0 0.0 34 24 39 26 25 7

8 10 24 14 1 5 14 27 28 23 31 0.8 0.6

0. 9 0.6 0.6 0.2 0.2 0.2 0.6 0.3 0.3 0.3 0.6 0.6
0. 5 0.7 196 145 1 36 122 87 49 51 92 103 112 1 06 109 107 1 1 0 154 1 54 4.5 3.4 3.2 2.8 2.0 1.I 1.2 2.1 2.4 2.6 2.5 2.5 2.5 2.6 3.6 3.6 171 96 59 32 16 15 57 117 133 125 80 92 105 108 205 139 4.0 2.2 1.4 0.7 0.4 0.3 1.3 2.7 3.1 2.9 1. 9 2.1 2.4 2.5 4.8 3.2 20 18 3

1 6

3 17 58 37 12 5

14 96 81 94 56 0.5 0.4

0. 1 0.0 0.1
0. 1 0.4 1.3
0. 9 0.3
0. 1 0.3 2.2
1. 9 2.2 1.3 4

0 0

0 0

0 1

7 1

0 2

1 3 9

1 5 4

0.1 0.0

0. 0 0.0 0.0 0.0 0.0 0.2 0.0 0.0
0. 0 0.0 0.3 0.2 0.3 0.1 0

0 0

0 0

0 0

0 0

0 0

0 2

1 0

0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0
0. 0 0.0 0.0 0.0 0.0 0.0 425 283 237 181 134 74 134 284 298 263 207 231 350 337 491 384
9. 9 6.6 5.5
3. 1 1.7 3.1 6.6 6.9 6.1 4.8 5.4 8.1 7.8 11.4 8.9 0

0.0 349 8.1 1833 42.5 1550 35.9 521 12.1 57 1.3 3

0.1 4313 100.0 MISSING HOURS:

103 MEAN WIND SPEED:

8.1

ARTIFICIAL ISLAND 7/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

DIRECTION VS SPEED ONLY WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 34 24 39 26 25 7

8 10 24 14 15 14 27 28 23 31 0.8 0.6 0.9 0.6 0.6 0.2 0.2 0.2 0.6 0.3 0.3 0.3 0.6 0.6

0. 5 0.7 196 145 136 122 87 49 51 92 103 112 106 109 107 1 1 0 154 154 4.5 3.4 3.2 2.8 2.0 1. 1 1.2 2.1 2.4 2.6 2.5 2.5 2.5
2. 5 3.6 3.6 171 96 59 32 16 15 57 117 135 125 80 92 105 108 205 139 4.0 2.2 1.4 0.7 0.4 0.3 1.3 2.7 3.1 2.9
1. 9 2.1 2.4 2.5 4.8 3.2 20 18 3

1 6

3 17 58 37 12 5

14 96 81 94 56 0.5 0.4 0.1 0.0

0. 1'
0. 1 0.4 1.3
0. 9 0.3
0. 1 0.3 2.2
1. 9 2.2 1.3 4

0 0

0 0

0 1

7 1

0 1

2 13 9

15 4

0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.0 0.0 0.0 0.0 0.3 0.2 0.3

0. 1 0

0 0

0 0

0 0

0 0

0 0

0 2

1.

0 0

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 425 283 237 181 134 74 134 284 300 263 207 231 350 337 491 384 9.8 6.6 5.5 4.2 3.1 1.7 3.1 6.6 7.0 6.1 4.8 5.4 8.1 7.8 11.4 8.9 0

0.0 349 8.1 1833 42.5 1552 36.0 521 12.1 57 1.3 3

0.1 4315 100.0 MISSING HOURS:

101 MEAN WIND SPEED:

8.1

ARTIFICIAL ISLAND 7/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STA1I3LITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE:

LE -1.9 DEG C/l00M CLASS A WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

0. 0
0. 0
0. 0
0. 0 0.0
0. 0 0.0
0. 0 0.0
0. 0 0.0
0. 0
0. 0 0.0
0. 0
0. 0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0
0. 0 0.0 0.0 0

0 0

0 0

0 0

4 4

7 0

0 0

1 0

0.0 0.0 0.0

0. 0 0.0 0.0
0. 0
0. 1
0. 1 0.2 0.0
0. 0 0.0 0.0 0.0 0.0 0

0 1

0 0

3 6

0 3

6 2

2 0

2 0

0.0 0.0

0. 0 0.0 0.0
0. 0
0. 1
0. 1 0.0
0. 1
0. 1 0.0 0.0 0.0 0.0
0. 0 3

0 0

0 0

0 0

2 0

1 2

5 3

0 2

0.1

0. 0 0.0 0.0 0.0 0.0 0.0
0. 0
0. 0 0.0
0. 0 0.0 0.1 0.1 0.0 0.0 1

0 0

0 0

0 0

1 0

0 0

0 2

4 4

2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 1

2 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 4

0 1

1 0

0 3

1 3 4

1 1 8

4 9

7 8

6 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.3

0. 1 0.3 0.2 0.1 0.2 0.2 0.2 0.1 0

0.0 0

0.0 17 0.4 26 0.6 19 0.4 14 0.3 3

0.1 79 1.8 MEAN WIND SPEED:

MISSING:

13.2 14

ARTIFICIAL ISLAND 7/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE: -1.8 TO -1.7 DEG C/1OOM CLASS B WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE EN1E E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0
0. 0 0.0 0.0
0. 0
0. 0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 2

0 0

0 0

0 0

I

0. 0 0.0 0.0 0.0
0. 0 0.0 0.0 0.0
0. 0
0. 0
0. 0
0. 0
0. 0 0.0
0. 0
0. 0 6

3 0

0 0

5 6

3 S

4 0

3 4

0. I 0.0
0. I 0.0 0.0 0.0 0.0
0. I
0. 1
0. I
0. I
0. I
0. I 0.0
0. I 0.1 4

5 6

0 3

1 3

6 3

5 4

8 2

2 8

9

0. I
0. I
0. 1
0. 0 0.1
0. 0
0. I
0. I
0. 1
0. I
0. 1

().2 0.0 0.0 0.2 0.2 12 2

1 0

0 0

5 5

0 0

7 1 0 8

1 0.3 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.0 0.0

0. 0 0.1 0.2 0.2 0.2 0.0 2

0 0

0 0

0 1

0 0

0 0

3 3

1 3 6

0 0.0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0. 1 0.3 0.1 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 4

1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 24 8

10 0

3 1

10 17 11 8

11 16 16 25 29 15 0.6 0.2 0.2 0.0 0.1 0.0 0.2 0.4 0.3 0.2 0.3 0.4 0.4 0.6 0.7 0.4 0

0.0 3

0.1 45 1.1 69 1.6 56 1.3 26 0.6 5

0.1 204 4.8 MEAN WIND SPEED:

12.1 MISSING:

15

ARTIFICIAL ISLAND 7/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE: -1.6 TO -1.5 DEG C/lOOM CLASS C WIND SPEED GROUPS (MPH) 0.0-0.5 DIRECTION SUM PERCENT 0.6-3.5 SUM PERCENT 3.6-7.5 SUM PERCENT 7.6-12.5 SUM PERCENT 12.6'18.5 SUM PERCENT 18.6-24.5 SUM PERCENT GE 24.6 SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0

0. 0 0.0
0. 0 0.0 0.0 0.0
0. 0 0.0 0.0
0. 0 0.0
0. 0 0.0 0.0
0. 0 2

0 0

0 0

1 0

1 2

0 4

0 0

0 I

0.0 0.0 0.0 0.0

0. 0 0.0 0.0
0. 0 0.0 0.0
0. 1 0.0
0. 0 0.0
0. 0 0.0 7

4 5

0 1

1 2

11 3

8 9

9 7

5 4

18 0.2

0. 1
0. 1 0.0 0.0 0.0 0.0 0.3
0. 1 0.2 0.2 0.2 0.2
0. 1
0. 1 0.4 18 17 9

0 1

0 5

6 3

5 6

6 7

4 9

13 0.4 0.4 0.2 0.0

0. 0 0.0 0. 1 0. 1
0. 1
0. 1
0. 1
0. 1 0.2
0. 1 0.2 0.3 4

2 2

0 2

0 3

6 3

4 1

10 10 1 0 3

11

0. 1 0.0 0.0
0. 0 0.0 0.0
0. 1
0. 1
0. 1
0. 1 0.0 0.2 0.2 0.2
0. 1 0.3 2

0 0

0 0

0 1

1 0

1 0

1 2

1 0 2

3 0.0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.0
0. 1 0

0 0

0 0

0 0

0 0

0 0

0 0

4 3

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 1 0.1 0.0 33 23 1 6 0

4 2

11 25 11 18 20 26 2 6 33 22 46 0.8 0.5 0.4 0.0

0. 1 0.0 0.3 0.6 0.3 0.4 0.5 0.6 0.6 0.8 0.5 1.1 0

0.0 12 0.3 94 2.2 109 2.5 71 1.7 23 0.5 7

0.2 316 7.4 MEAN WIND SPEED:

10.8 MISSING:

8

ARTIFICIAL ISLAND 7/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T:

(300-33FT)

LAPSE RATE: -1.4 TO -0.5 DEG C/1OOM CLASS D WIND SPEED GROUPS (MPH)

0. 0-0. 5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 5

0.1 8

0.2 6

0.1 2

0.0 2

0.0 2

0.0 4

0.1 3

0.1 6

0.1 7

0.2 3

0.1 7

0.2 4

0.1 3

0.1 4

0.1 7

0.2 29 0.7 46 1.1 26 0.6 20 0.5 40 0.9 26 0.6 35 0.8 50 1.2 30 0.7 25 0.6 33 0.8 15 0.4 21 0.5 21 0.5 5

0.1 8

0.2 18 0.4 2

0.0 6

0.1 30 0.7 35 0.8 33 0.8 54 1.3 70 1.6 26 0.6 41 1.0 49 1.1 31 0.7 60 1.4 34 0.8 27 0.6 49 1.1 20 0.5 14 0.3 33 0.8 16 0.4 23 0.5 38 0.9 58 1.4 27 0.6 35 0.8 48 1.1 19 0.4 20 0.5 67 1.6 29 0.7 32 0.7 12 0.3 1

0.0 8

0.2 6

0.1 1

0.0 2

0.0 0

0.0 6

0.1 19 0.4 3

0.1 2

0.0 2

0.0 2

0.0 20 0.5 54 1.3 39 0.9 15*

0.4 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 2

0.0 3

0.1 0

0.0 1

0.0 0

0.0 1

0.0 0

0.0 7

0.2 17 0.4 11 0.3 4

0.1 107 2.5 102 2.4 127 3.0 76

1. 8 51 1.2 32 0.7 84 2.0 179 4.2 126 2.9 134 3.1 102 2.4 72 1.7 150 3.5 184 4.3 160 3.7 99 2.3 0

0.0 73 1.7 373 8.7 600 14.0 513 12.0 180 4.2 46 1.1 1785 41.7 MEAN WIND SPEED:

11.8 MISSING:

13

ARTIFICIAL ISLAND 7/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE: -0.4 TO 1.5 DEG C/1OOM CLASS E WIND SPEED GROUPS (MPH) 0.0-0.5 DIRECTION SUM PERCENT 0.6-3.5 SUM PERCENT 3.6-7.5 SUM PERCENT 7.6-12.5 SUM PERCENT

12. 6-18. 5 SUM PERCENT 18.6-24.5 SUM PERCENT GE 24.6 SUM PERCENT SUM PERCENT N

NNE NE EWE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

0. 0 0.0 0.0
0. 0 0.0
0. 0 0.0
0. 0 0.0 0.0 0.0 0.0
0. 0
0. 0 0.0 0.0 3

3 5

7 7

4 2

2 2

5 3

7 6

6

0. 1 0.1
0. I 0.2 0.2 0.1 0.0 0.0
0. 0
0. 0
0. 1
0. 1 0.2
0. 1
0. 1 14 26 21 20 14 20 12 12 13 10 17 13 30 27 22 13 0.3 0.6 0.5 0.5 0.3 0.5 0.3 0.3 0.3 0.2 0.4 0.3 0.7 0.6 0.5 0.3 49 62 34 28 29 9

20 21 12 38 65 37 46 45 72 35 1.1 1.4 0.8 0.7 0.7 0.2 0.5

0. 5 0.3 0.9 1.5
0. 9 1.1 1.1 1.7 0.8 62 39 14 10 5

3 6

5 9

31 21 10 24 19 81 34 1.4

0. 9 0.3 0.2
0. 1
0. 1
0. 1
0. 1 0.2 0.7 0.5 0.2 0.6 0.4
1. 9 0.8 5

0 3

0 2

1 9

3 0

1 3

0 6

1 4

6

0. 1 0.0
0. 1 0.0 0.0 0.0 0.2
0. 1 0.0 0.0 0.1 0.0 0.1 0.0 0.1 0.1 0

0 0

0 0

0 5

0 0

I 3

1 1

0 0

1 0.0 0.0 0.0 0.0 0.0 0.0

0. 1 0.0 0.0 0.0
0. 1 0.0 0.0 0.0 0.0 0.0 133 130 77 65 57 37 54 43 36 82 114 64 112 99 185 95 3.1 3.0 1.8 1.5 1.3
0. 9 1.3 1.0 0.8
1. 9 2.7 1.5 2.6 2.3 4.3 2.2 0

0.0 68 1.6 284 6.6 602 14.1 373 8.7 44 1.0 12 0.3 1383 32.3 MEAN WIND SPEED:

10.6 MISSING:

64

ARTIFICIAL ISLAND 7/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE:

1.6 TO 4.0 DEG C/1OOM CLASS F WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

1. 6-12. 5 12.6-18.5
18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0 0

0 3

2 2

0 0

0 0

2 4

1 2

0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 5

4 3

7 1 4 8

8 5

5 5

1 5

6 8

9 7

0.1

0. 1
0. 1 0.2 0.3 0.2 0.2
0. 1
0. 1
0. 1 0.0
0. 1
0. 1 0.2 0.2 0.2 17 30 18 10 20 13 6

0 2

6 20 6

25 9

14 17 0.4 0.7 0.4 0.2 0.5 0.3

0. 1
0. 0 0.0
0. 1 0.5
0. 1 0.6 0.2 0.3 0.4 23 2

5 3

1 2

0 0

5 3

5 2

2 7

1 2 0.5 0.0 O.1

0. 1 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.0 0.0 0.2 0.3 1

0 0

0 0

0 1

0 0

0 1

1 7

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.0 0.0 0.0 0

0 0

0 0

0 4

2 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.1I 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 46 36 29 22 37 23 21 7

7 16 26 19 44 20 31 38 1.1 0.8 0.7 0.5

0. 9 0.5 0.5 0.2 0.2 0.4 0.6 0.4 1.0 0.5 0.7
0. 9 0

0.0 19 0.4 100 2.3 213 5.0 73 1.7 11 0.3 6

0.1 422 9.9 MEAN WIND SPEED:

10.0 MISSING:

24

ARTIFICIAL ISLAND 7/00-12/00 JOINT [)ISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABIlITY CLASS WIND:

150 FT DELTA T: 1300-33FT)

LAPSE RATE:

GT 4.0 DEG C/looM CLASS G WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0

0. 0 0.0 0.0
0. 0 0.0
0. 0 0.0 0.0
0. 0 0.0 0.0 0.0 0.0 1

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0

0. 0
0. 0 0.0 0.0 0.0
0. 0 0.0
0. 0 0.0 0.0
0. 0 0.0 0.0 0.0 3

5 3

3 0

0 0

0 0

4

0. 0
0. 1
0. I
0. I
0. 1 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0. 0 0.0 0.1 0.0 2

6 7

1 0

1° 2

0 1° I

3 3

4 2

0.0 0.0

0. 1
0. 1 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0. I
0. 1
0. 1 0.0 0

0 3

1 0

1 0

1 0

3 1

1 0

0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0
0. 1 0.0 0.0 0.0 0

0 0

0 0

0 1

0 0

0 0

0 0

0 0

0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

9 1

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 3

5 1 4 8

11 I 1 2

11 0

3 2

6 4

9 3

0.1 0.1 0.3 0.2 0.3 0.0 0.0 0.3 0.1 0.0 0.1 0.0 0.1

0. 1 0.2 0.1 0

0.0 1

0.0 24 0.6 38 0.9 13 0.3 0.0 10 0.2 87 2.0 MEAN WIND SPEED:

12.0 MISSING:

0

ARTIFICIAL ISLAND 7/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

ALL STABILITY CLASSES WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7. 5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 11 0.3 62 1.4 13.5 3.2 130 3.0 12 0.3 0

0.0 0

0.0 11 0.3 58 1.4 156 3.6 71 1.7 8

0.2 0

0.0 0

0.0 14 0.3 72 1.7 124 2.9 55 1.3 9

0.2 0

0.0 0

0.0 11 0.3 55 1.3 76 1.8 29 0.7 1

0.0 0

0.0 0

0.0 11 0.3 53 1.2 81 1.9 14 0.3 4

0.1 0

0.0 0

0.0 7

0.2 38 0.9 42 1.0 7

0.2 1

0.0 2

0.0 0

0.0 7

0.2 29 0.7 67 1.6 51 1.2 19 0.4 12 0.3 0

0.0 6

0.1 70 1.6 94 2.2 89 2.1 25 0.6 11 0.3 0

0.0 12 0.3 58 1.4 63 1.5 61 1.4 3

0.1 2

0.0 0

0.0 8

0.2 64 1.5 117 2.7 75 1.8 4

0.1 1

0.0 0

0.0 14 0.3 61 1.4 151 3.5 48 1.1 6

0.1 4

0.1 0

0.0 12 0.3 46 1.1 93 2.2 47 1.1 4

0.1 1

0.0 0

0.0 13 0.3 70 1.6 123 2.9 109 2.5 40 0.9 8

0.2 0

0.0 11 0.3 67 1.6 98 2.3 93 2.2 82 1.9 21 0.5 0

0.0 12 0.3 62 1.4 129 3.0 167 3.9 55 1.3 19 0.4 0

0.0 16 0.4 72 1.7 108 2.5 72 1.7 26 0.6 8

0.2 0

0.0 176 4.1 937 21.9 1657 38.8 1118 26.1 299 7.0 89 2.1 350 8.2 304 7.1 274 6.4 172 4.0 163 3.8 97 2.3 185 4.3 295 6.9 199 4.7 269 6.3 284 6.6 203 4.7 363 8.5 372 8.7 444 10.4 302 7.1 4276 100.0 MISSING HOURS:

140 MEAN WIND SPEED:

11.2

ARTIFICIAL ISLAND 7/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY ClASS WIND:

150 FT DELTA T:

(300-33FT)

DIRECTION VS SPEED ONLY WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 11 0.3 62 1.4 135 3.2 130 3.0 0

0.0 11 0.3 58 1.4 156 3.6 71 1.7 0

0.0 14 0.3 72 1.7 124 2.9 55 1.3 0

0.0 11 0.3 55 1.3 76 1.8 29 0.7 0

0.0 11 0.3 53 1.2 81 1.9 14 0.3 0

0.0 7

0.2 38 0.9 42 1.0 7

0.2 0

0.0 7

0.2 29 0.7 67 1.6 51 1.2 0

0.0 6

0.1 70 1.6 94 2.2 89 2.1 0

0.0 12 0.3 58 1.4 64 1.5 62 1.4 0

0.0 8

0.2 64 1.5 117 2.7 75 1.8 0

0.0 14 0.3 61 1.4 151 3.5 48 1.1 0

0.0 12 0.3 46 1.1 93 2.2 47 1.1 0

0.0 13 0.3 70 1.6 123 2.9 109 2.5 0

0.0 11 0.3 67 1.6 98 2.3 93 2.2 0

0.0 12 0.3 62 1.4 129 3.0 167 3.9 0

0.0 16 0.4 72 1.7 108 2.5 72 1.7 12 0.3 8

0.2 9

0.2 1

0.0 4

0.1 1

0.0 19 0.4 25 0.6 3

0.1 4

0.1 6

0.1 4

0.1 40 0.9 82 1.9 55 1.3 26 0.6 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 2

0.0 12 0.3 11 0.3 2

0.0 1

0.0 4

0.1 1

0.0 8

0.2 21 0.5 19 0.4 8

0.2 350 8.2 304 7.1 274 6.4 172 4.0 163 3.8 97 2.3 185 4.3 295 6.9 201 4.7 269 6.3 284 6.6 203 4.7 363 8.5 372 8.7 444 10.4 302 7.1 0

0.0 176 4.1 937 21.9 1658 38.8 1119 26.2 299 7.0 89 2.1 4278 100.0 MISSING HOURS:

138 MEAN WIND SPEED:

11.2

ARTIFICIAL ISLAND 7/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T:

(300-33FT)

LAPSE RATE:

LE -1.9 DEG C/lO0M CLASS A WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0
0. 0
0. 0 0.0 0.0 o.0 0.0 0

0 0

0 0

0 2

4 2

6 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 1 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

1 0

0 4

5 0

6 2

1 2

0 1

1 0.0

0. 0
0. 0
0. 0 0.0
0. 0
0. 1
0. 1 0.0
0. 1 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

1 0

0 2

0 0

4 0

4 2

1 3

4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 1 0.0
0. 1 0.0 0.0 0.1 0.1 0

0 0

0 0

0 0

1 0

0 0

0 7

4 10 3

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.1 0.2

0. 1 1

0 0

0 0

0 0

0 0

0 0

0 0

0 4

3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 1

0 0

2 0

0 8

10 2

16 3

5 11 6

18 11 0.0 0.0

,0.0 0.0 0.0 0.0 0.2 0.2 0.0 0.4 0.1

0. 1 0.2 0.1 0.4 0.2 0

0.0 0

0.0 16 0.4 23 0.5 21 0.5 25 0.6 8

0.2 93 2.1 MEAN WIND SPEED:

15.1 MISSING:

0

ARTIFICIAL ISLAND 7/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPIIERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE: -1.8 TO -1.7 DEG C/1OOM CLASS B WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5

3. 6-7. 5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

0. 0
0. 0 0.0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0 0

0 0

0 0

0 0

2 0

0 0

0 0

0

0. 0 0.0 0.0
0. 0 0.0
0. 0
0. 0
0. 0 0.0
0. 0
0. 0
0. 0
0. 0
0. 0 0.0 0.0 2

0 0

0 0

0 4

4 2

3 2

2 0.0 0.0

0. 0
0. 0
0. 0
0. 0
0. 0
0. 1
0. 1
0. I
0. I
0. 0
0. I
0. 1 0.0 0.0 5

8 0

0 2

U 5

4 5

7 13 12 0.1 0.2

0. 0
0. 0
0. 0
0. 0
0. I
0. 1
0. 1
0. 1
0. I 0.2 0.0
0. 1 0.3 0.3 4

2 0

0 6

2 0

3 2

5 4

4 5

0.1 0.0 0.0 0.0 0.0

0. 0
0. 1 0.0 0.0
0. I
0. 0
0. 1
0. 1 0.1 0.1 0

0 0

0 0

0 3

0 0

0 0

2 13 13 8

6 0.0 0.0 0.0 0.0 0.0 0.0

0. 1 0.0 0.0 0.0 0.0 0.0 0.3 0.3 0.2 0.1 1

0 0

0 0

0 0

0 0

0 0

0 0

0 7

2 0.0 0.0 0.0 0.0

0. 0 0.0 0.0
0. 0 0.0
0. 0 0.0 0.0 0.0 0.0 0.2 0.0 12 1 0 0

0 3

1 15 12 10 13 10 1 6 22 24 36 35 0.3 0.2 0.0 0.0 O'. 1 0.0 0.3 0.3 0.2 0.3 0.2 0.4 0.5 0.5 0.8 0.8 13 0.3 0

0.0 4

0.1 33 0.7 74 1.7 52 1.2 46 1.0 10 0.2 219 5.0 MEAN WIND SPEED:

13.4 MISSING:

0

ARTIFICIAL ISLAND 7/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABII.TY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE: -1.6 TO -1.5 DEG C/100M CLASS C WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18. 5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 1

1 0

0 0

0 2

2 1

0 1

0.0

0. 0 0.0
0. 0
0. 0
0. 0 0.0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0 0.0
0. 0
0. 0 5

5 1

0 2

2 4

8 4

5 8

8 8

5 1 1 1 0 0.1

0. 1
0. 0
0. 0 0.0 0.0
0. 1 0.2
0. I
0. 1 0.2 0.2 0.2
0. 1 0.2 0.2 13 12 2

0 1

0 6

5 3

6 7

7 9

12 28 0.3 0.3 0.0

0. 0 0.0
0. 0
0. 1
0. 1
0. 1
0. 1 0.2 0.2 0.2
0. 0 0.3 0.6 1

4 1

1 7

2 4

6 1 1 2

1 2 8

0.0

0. 1 0.0 0.0 0.0 0.0 0.2 0.0
0. 1 0.0
0. 1
0. 1 0.2 0.0 0.3 0.2 0

0 0

0 0

0 1

0 0

1 4

9 6

4 4

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0
0. 1 0.2 0.1
0. 1
0. 1 0

0 0

0 0

0 0

0 0

0 0

0 4

4 5

3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 20 22 4

1 4

3 19 17 14 15 20 26 42 19 45 53 0.5 0.5 0.1 0.0

0. 1
0. 1 0.4 0.4 0.3 0.3 0.5 0.6 1.0 0.4 1.0 1.2 0

0.0 13 0.3 86 2.0 112 2.5 67 1.5 30 0.7 16 0.4 324 7.4 MEAN WIND SPEED:

11.6 MISSING:

0

ARTIFICIAL ISLAND 7/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33ET)

LAPSE RATE: -1.4 TO -0.5 DEG C/1OOM CLASS D WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12. 5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

0. 0 0.0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0
0. 0 0.0 0.0 0.0 0.0 8

8 3

2 1

3 9

8 7

4 4

5 6

5 4

S 0.2 0.2

0. 1
0. 0 0.0
0. 1 0.2 0.2 0.2
0. 1
0. 1
0. 1
0. 1
0. 1
0. 1
0. 1 1 7 1 3 20 2 0 16 7

1 3 22 24 22 1 6 1 6 22 27 1 7 18a 0.4 0.3 0.5

0. 5 0.4 0.2 0.3
0. 5
0. 5
0. 5 0.4 0.4 0.5 0.6 0.4 0.4 36 36 37 21 21 15 30 46 39 41 42 25 34 30 14 52 0.8 0.8 0.8
0. 5
0. 5 0.3 0.7 1.0
0. 9
0. 9 1.0 0.6 0.8 0.7 0.3 1.2 25 4 1 22 20 7

1 4 4 8 7 0 4 6 52 23 18 65 45 46 22 0.6

0. 9 0.5 0.5 0.2 0.3 1.1 1.6 1.0 1.2
0. 5 0.4 1.5 1.0 1.0 0.5 8

16 3

2 2

0 18 19 6

11 1

4 42 48 39 10 0.2 0.4

0. 1 0.0 0.0 0.0 0.4 0.4 0.1 0.2 0.0 0.1 1.0 1.1
0. 9 0.2 1

0 0

0 1

3 4

1 1

1 0

1 29 25 2 6 1 3 0.0 0.0 0.0 0.0 0.0 0.1

0. 1 0.0 0.0 0.0 0.0 0.0 0.7 0.6 0.6 0.3 95 114 85 65 48 42 122 166 123 131 86 69 198 180 146 120 2.2 2.6
1. 9
1. 5 1.1 1.0 2.8 3.8 2.8 3.0 2.0 1.6 4.5 4.1 3.3 2.7 0

0.0 82 1.9 290 6.6 519 11.8 564 12.8 229 5.2 106 2.4 1790 40.7 MEAN WIND SPEED:

13.2 MISSING:

8

ARTIFICIAL ISLAND 7/00-1?/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T:

(300-33FT)

LAPSE RATE: -0.4 TO 1.5 DEG C/1OOM CLASS E WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18. 5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0

0. 0
0. 0 0.0
0. 0 0.0 0.0 0.0
0. 0
0. 0 0.0
0. 0
0. 0
0. 0 0.0 2

2 5

2 3

2 2

4 4

3 14 3

0. 0
0. 0
0. I
0. 0
0. 1 0.0 0.2
0. 0

(. I

0. I
0. I
0. I 0.0
0. I
0. I
0. 0 12 1 2 13 9

15 1 1 12 6

15 12 10 16 22 24 11 1 2 0.3 0.3 0.3 0.2 0.3 0.2 0.3

0. 1 0.3 0.3 0.2 0.4 0.5
0. 5 0.2 0.3 32 19 1 1 19 32 1 0 17 16 1 1 17 30 22 33 33 45 21 0.7 0.4 0.2 0.4 0.7 0.2 0.4 0.4 0.2 0.4 0.'7 0.5 0.7 0.7
1. 0 0.5 76 55 12 18 12 8

10 7

24 45 42 37 34 41 100 57 1.7 1.2 0.3 0.4 0.3 0.2 0.2 0.2

0. 5 1.0 1.0 0.8 0.8
0. 9 2.3 1.3 31 6

0 0

2 0

4 3

4 20 12 6

15 7

59 27 0.7

0. 1 0.0 0.0
0. 0 0.0
0. I 0.1
0. 1 0.5 0.3
0. 1 0.3 0.2 1.3 0.6 5

2 1

0 2

1 1 1 0

0 1

3 3

2 0

2 7

0.1 0.0 0.0 0.0 0.0 0.0 0.2

0. 0 0.0 0.0
0. 1
0. 1
0. 0
0. 0
0. 0 0.2 158 96 42 48 66 32 61 34 58 99 101 87 107 109 220 125 3.6 2.2 1.0
1. 1 1.5 0.7 1.4 0.8 1.3 2.2 2.3 2.0 2.4 2.5 5.0 2.8 0

0.0 49 1.1 212 4.8 368 8.4 578 13.1 196 4.5 40 0.9 1443 32.8 MEAN WIND SPEED:

13.3 MISSING:

4

ARTIFICIAL ISLAND 7/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T:

(300-33FT)

LAPSE RATE:

1.6 TO 4.0 DEG C/1OOM CLASS F WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6 18.5 18.6-24.5 GE 24.6 SUM PERCENT IIIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0
0. 0 0.0
0. 0 0.0 0.0 0.0 0.0 0.0
0. 0 0

0 1

0 3

2 0

0 3

1 2

0 0

3 0

0 0.0 0.0 0.0 0.0

0. 1 0.0 0.0
0. 0
0. 1 0.0
0. 0 0.0 0.0
0. 1 0.0 0.0 3

1 1

4 1 0 7

7 8

5 1

4 2

5 3

4 1

0. 1
0. 0 0.0
0. 1 0.2 0.2 0.2 0.2
0. 1 0.0
0. 1 0.0
0. 1
0. 1
0. 1 0.0 15 S

4 6

12 12 5

1 2

S 4

6 12 1 1 8

16 0.3

0. 1
0. 1
0. 1 0.3 0.3
0. 1 0.0 0.0 0.1
0. 1
0. 1 0.3 0.2 0.2 0.4 26 19 6

3 13 6

3 0

1 9

8 11 8

5 21 38 0.6 0.4

0. 1 0.1 0.3
0. 1
0. 1 0.0 0.0 0.2 0.2 0.2 0.2
0. 1 0.5
0. 9 5

5 5

0 1

1 0

1 0

4 8

7 4

0 7

5 0.1 0.1 0.1 0.0

0. 0 0.0 0.0 0.0 0.0 0.1 0.2 0.2 0.1 0.0 0.2
0. 1 0

0 0

0 0

0 1

4 1

0 0

2 3

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 1 0.0 0.0 0.0 0.0
0. 1 0.0 0.0 0.0 4 9 30 17 13 39 28 1 6 14 12 20 26 28 32 22 40 60
1. 1 0.7 0.4 0.3
0. 9 0.6 0.4 0.3 0.3 0.5 0.6 0.6 0.7 0.5 0.9 1.4 0

0.0 15 0.3 66 1.5 124 2.8 177 4.0 53 1.2 11 0.2 446 10.1 MEAN WIND SPEED:

13.2 MISSING:

0

ARTIFICIAL ISLAND 7/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE:

GT 4.0 DEG C/100M CLASS G WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18. 5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0 0.0
0. 0
0. 0 0.0
0. 0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0
0. 0 0.0 0.0 0.0
0. 0 0.0 0.0 0.0 1

1 2

4 5

0 0

0 0

0 0

0 0.0 0.0 0.0 0.1 0.1 0.0 0.0 0.0

0. 0 0.0 0.0 0.0
0. 0 0.0 0.0 0.0 0

1 6

3 3

2 1

0 0

212 2

3 0

0.0 0.0 0.1 0.1

0. 1 0.0
0. 0 0.0 0.0 0.0
0. 0 0.0 0.0 0.0
0. 1 0.0 1

2 0

0 2

5 0

1 0

0 2

2 3

4 2

0.0 0.0 0.0 0.0 0.0 0.1

0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.1
0. 1 0.0 0

1 2

0 0

0 0

1 1

0 2

0 3

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0

0 0

0 0

0 0

7 3

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 2

5 10 7

10 B

1 9

4 3

3 4

6 5

7 3

0.0 0.1 0.2 0.2

0. 2 0.2 0.0 0.2
0. 1
0. 1
0. 1
0. 1
0. 1
0. 1 0.2 0.1 0

0.0 MEAN WIND SPEED:

14.8 MISSING:

0 0

0.0 17 0.4 25 0.6 25 0.6 10 0.2 10 0.2 87 2.0

ARTIFICIAL ISLAND 7/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

ALL STABILITY CLASSES WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18. 5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE EN E E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0

0. 0 0.0 0.0
0. 0 0.0 0.0 0.0
0. 0
0. 0
0. 0 0.0
0. 0 0.0 0.0 11 11 9

4 7

7 17 13 18 10 11 9

8 13 9

6 0.2 0.2 0.2

0. 1 0.2 0.2 0.4 0.3 0.4 0.2 0.2 0.2 0.2 0.3 0.2
0. 1 40 32 37 37 48 2 8 3 9 52 5 4 52 44 44 61 63 45 44 0.9 0.7 0.8 0.8 1.1 0.6
0. 9 1.2 1.2 1.2
1. 0 1.0 1.4 1.4
1. 0 1.0 101 81 60 50 71 39 68 77 59 81 89 70 92 81 96 130 2.3 1.8 1.4
1. 1 1.6
0. 9 1.5 1.7 1.3 1.8 2.0 1.6 2.1 1.8 2.2 3.0 133 123 41 43 36 35 76 81 76 116 79 83 126 101 191 144 3.0 2.8 0.9 1.0 0.8 0.8 1.7 1.8 1.7 2.6 1.8
1. 9 2.9 2.3 4.3 3.3 44 28 10 2

5 1

26 27 11 36 23 23 93 78 127 55 1.0 0.6 0.2 0.0

0. 1
0. 0 0.6 0.6 0.2 0.8 0.5 0.5 2.1 1.8 2.9 1.2 8

2 1

0 3

4 1 6 1 2 5

2 3

6 38 2 9 4 4 28 0.2 0.0 0.0 0.0 0.1

0. 1 0.4 0.3
0. 1
0. 0
0. 1 0.1
0. 9 0.7 1.0 0.6 337 277 158 136 170 114 242 262 223 297 249 235 418 365 512 407 6.3 3.6 3.1 3.9 2.6 5.5 6.0 5.1 6.7 5.7 5.3 9.5 8.3 11.6 9.2 0

0.0 163 3.7 720 16.4 1245 28.3 1484 33.7 589 13.4 201 4.6 4402 100.0 MISSING HOURS:

14 MEAN WIND SPEED:

13.2

ARTIFICIAL ISLAND 7/00-12/00 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

DIRECTION VS SPEED ONLY WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 11 0.2 40 0.9 10U 2.3 133 3.0 44 1.0 8

0.2 0

0.0 11 0.2 32 0.7 81 1.8 123 2.8 28 0.6 2

0.0 0

0.0 9

0.2 37 0.8 60 1.4 41 0.9 10 0.2 1

0.0 0

0.0 4

0.1 37 0.8 50 1.1 43 1.0 2

0.0 0

0.0 0

0.0 7

0.2 48 1.1 71 1.6 36 0.8 5

0.1 3

0.1 0

0.0 7

0.2 28 0.6 39 0.9 35 0.8 1

0.0 4

0.1 0

0.0 17 0.4 39 0.9 68 1.5 76 1.7 26 0.6 16 0.4 0

0.0 13 0.3 52 1.2 77 1.7 81 1.8 27 0.6 12 0.3 0

0.0 18 0.4 54 1.2 60 1.4 76 1.7 11 0.2 5

0.1 0

0.0 10 0.2 52 1.2 81 1.8 116 2.6 36 0.8 2

0.0 0

0.0 11 0.2 44 1.0 89 2.0 79 1.8 23 0.5 3

0.1 0

0.0 9

0.2 44 1.0 70 1.6 83 1.9 23 0.5 6

0.1 0

0.0 8

0.2 61 1.4 92 2.1 126 2.9 93 2.1 38 0.9 0

0.0 13 0.3 63 1.4 81 1.8 101 2.3 78 1.8 29 0.7 0

0.0 9

0.2 45 1.0 96 2.2 191 4.3 127 2.9 44 1.0 0

0.0 6

0.1 44 1.0 130 3.0 144 3.3 55 1.2 28 0.6 0

0.0 163 3.7 720 16.4 1246 28.3 1484 33.7 589 13.4 201 4.6 337 7.7 277 6.3 158 3.6 136 3.1 170 3.9 114 2.6 242 5.5 262 6.0 224 5.1 297 6.7 249 5.7 235 5.3 418 9.5 365 8.3 512 11.6 407 9.2 4403 100.0 MISSING HOURS:

13 MEAN WIND SPEED:

13.2

Section 1 300-33-ft. Lapse Rate Wind Distributions 1/00 - 3/00

APPENDIX B MPC DATA

APPENDIX F: Maximum Permissible Concentration (MPC) Values - Liquid Effluents The following radionuclide concentrations were obtained from 10 CFR 20 Appendix B. Table I. Column 2 as revised January 1. 1991 Table F-l: Maximum Permissible Concentrations Element Isotope Soluble Conc Insoluble Conc.

(PCi/ml)

(PCi/ml)

Actinium (89)

Ac-227 2E-6 3E-4 Ac-228 9E-5 9E-5 Americium (95)

Am-241 4E-6 3E-5 Am-242m 4E-6 9E-5 Am-242 I E-4 I E-4 Am-243 4E-6 3E-5 Am-244 5E-3 5E-3 Antimony (51)

Sb-122 3E-5 3E-5 Sb-124 2E-5 2E-5 Sb-125 IE-4 IE-4 Arsenic (33)

As-73 5E-4 5E-4 As-74 5E-5 5E-5 As-76 2E-5 2E-5 As-77 8E-5 8E-5 Astatine (85)

At-211 2E-6 7E-5 Barium (56)

Ba-131 2E-4 2E-4 Ba-140 3E-5 2E-5 Berkelium (97)

Bk-249 6E-4 6E-4 Bk-250 2E-4 2E-4 B3er Ihuliu (4)

Be-7 2E-3 2E-3 B3ismuth (83)

Bi-206 4E-5 4E-5 Bi-207 6E-5 6E-5 Bi-210 4E-5 4E-5 Bi-212 4E-4 4E-4 Bromine (35)

Br-82 3E-4 4E-5 Cadmium (48)

Cd-109 2E-4 2E-4 Cd-I 15m 3E-5 3E-5 Cd-1 15 31:-5 4E-5 Calcium (20)

Ca-45 9E-6 2E-4 Ca-47 5E-5 3E-5 Calilaornium (98)

Ci:249 41:-6 21E-5 Cf-250 I L-5 3E-5 Ct:251 4E-6 3E-5 Cf-252 7E-6 7E-6 Cl:253 I E-4 I E-4 Ct:254 I E-7 I E-7

Table F-I (Continued)

Element Isotope Soluble Conc.

Insoluble Conc.

(ACi/ml)

(jICi/ml)

Carbon (6)

C-14 8E-4 Ccrium (58)

Ce-141 9E-5 9E-5 Ce-143 4E-5 4E-5 Ce-144 I E-5 I E-5 Cesium (55)

Cs-131 2E-3 9E-4 Cs-I 34m 6E-3 I E-3 Cs-134 9E-6 4E-5 Cs-135 IE-4 2E-4 Cs-136 9E-5 6E-5 Cs-137 2E-5 4E-5 Chlorine (17)

CI-36 8E-5 6E-5 CI-38 4E-4 4E-4 Chromium (24)

Cr-51 2E-3 2E-3 Cobalt (27)

Co-57 5E-4 4E-4 Co-58m 3E-3 2E-3 Co-58 I E-4 9E-5 Co-60 5E-5 3E-5 Copper (29)

Cu-64 3E-4 2E-4 Curium (96)

Cm-242 2E-5 2E-5 Cm-243 5E-6 2E-5 Cm-244 7E-6 3E-5 Cm-245 4E-6 3 E-5 Cm-246 4E-6 3E-5 Cm-247 4E-6 2E-5 Cm-248 4E-7 I E-6 Cm-249 2E-3 2E-3 DN)sproslum (66)

Dy-165 4E-4 4E-4 Dy-166 4E-5 4E-5 Einsteinium (99)

Es-253 2E-5 2E-5 Es-254m 2E-5 2E-5 Es-254 I E-5 I E-5 Es-255 3E-5 3E-5 Frbium (68)

Er-169 9E-5 9E-5 Er-171 IE-4 IE-4 luropium (63)

Eu-152 (9.2 hrs) 6E-5 6E-5 Eu-152 (13 vrs) 8E-5 8E-5 Eu-154 2E-5 2E-5 Eu-155 2E-4 2E-4 Fermium (100)

Fm-254 IE-4 IE-4 Fm-255 3E-5 3E-5 Fm-256 9E-7 9E-7

Table F-I (Continued)

Element Isotope Soluble Conc.

Insoluble Conc.

(PCi/ml)

(PiCi/ml)

Fluorine (9)

F-18 8E-4 5E-4 Gadolinium (64)

Gd-153 2E-4 2E-4 Gd-159 8E-5 8E-5 Gallium (31)

Ga-72 4E-5 4E-5 Germanium (32)

Ge-71 2E-3 2E-3 Gold (79)

Au-196 2E-4 IE-4 Au-198 5E-5 5 E-5 Au-199 2E-4 2E-4 Hafnium (72)

Hf-181 7E-5 7E-5 Holmium (67)

Ho-166 3E-5 3E-5 Hydrogen (3)

H-3 3E-3 3E-3 Indium (49)

In-I 13m IE-3 IE-3 In-1 14m 2E-5 2E-5 In-I 15m 4E-4 4E-4 In-I 15 9E-5 9E-5 Iodine (53) 1-125 2E-7 2E-4 1-126 3E-7 9E-5 1-129 6E-8 2E-4 1-131 3E-7 6E-5 1-132 8E-6 2E-4 1-133 IE-6 4E-5 1-134 2E-5 6E-4 1-135 4E-6 7E-5 Iridium (77)

Ir-190 2E-4 2E-4 Ir-192 4E-5 4E-5 Ir-194 3E-5 3E-5 Iron (26)

Fe-55 8E-4 2E-3 Fe-59 6E-5 5E-5 Lanthanum (57)

La-140 2E-5 2E-5 Lead (82)

Pb-203 4E-4 4E-4 Pb-210 1 E-7 2E-4 Pb-212 2E-5 2E-5 Lutetium (71)

Lu-177 I E-4 I E-4 Manganese (25)

Mn-52 3E-5 3E-5 Mn-54 I E-4 I E-4 Mn-56 I E-4 I E-4 Mcrcury (80)

Hg-197m 2E-4 2E-4 Hg-197 3E-4 5E-4 Hg-203 2E-5 I E-4 Molybdenum (42)

Mo-99 2E-4 4E-5

Table F-I (Continued)

Element Isotope Soluble Conc.

Insoluble Conc.

(ACi/mi)

(ACi/mI)

Neodymium (60)

Nd-144 7E-5 8E-5 Nd-147 6E-5 6E-S Nd-149 3E-4 3E-4 Neptunium (93)

Np-237 3E-6 3E-5 Np-239 I E-4 I E-4 Nickel (28)

Ni-59 2E-4 2E-3 Ni-63 3E-5 7E-4 Ni-65 I E-4 I E-4 Niobium (41)

Nb-93m 4E-4 4E-4 Nb-95 I E-4 I E-4 Nb-97 9E-4 9E-4 Osmium (76)

Os-185 7E-5 7E-5 Os-191m 3E-3 2E-3 Os-191 2E-4 2E-4 Os-193 6E-5 SE-S Palladium (46)

Pd-103 3E-4 3E-4 Pd-109 9E-5 7E-5 Phosphorus (15)

P-32 2E-5 2E-5 Platinum (78)

Pt-191 IE-4 IE-4 Pt-193m IE-3 IE-3 Pt-193 9E-4 2E-3 Pt-197m 1 E-3 9E-4 Pt-197 1E-4 IE-4 Plutonium (94)

Pu-238 5E-6 3E-5 Pu-239 5E-6 3E-5 Pu-240 5E-6 3E-5 Pu-241 2E-4 I E-3 Pu-242 5E-6 3E-5 Pu-243 3E-4 3E-4 Polonium (84)

Po-210 7E-7 3E-5 Potassium (19)

K-42 3E-4 2E-5 Prascodymium(59 Pr-142 3E-5 3E-5 Pr-143 5E-5 5E-5 Promethium (61)

Pm-147 2E-4 2E-4 Pm-149 4E-5 4E-5 Protactinium(91)

Pa-230 2E-4 2E-4 Pa-231 9E-7 2E-5 Pa-233 I E-4 I E-4

Table F-I (Continued)

Element Isotope Soluble Conc.

Insoluble Conc.

(giCi/ml)

(pCi/ml)

Radium (88)

Ra-223 7E-7 4E-6 Ra-224 2E-6 5E-6 Ra-226 3E-8 3E-5 Ra-228 3E-8 3E-5 Rhenium (75)

Re-183 6E-4 3 E-4 Re-186 9E-5 5 E-5 Re-187 3E-3 2E-3 Re-188 6E-5 3E-5 Rhodium (45)

Rh-103m IE-2 IE-2 Rh-105 I E-4 I E-4 Rubidium (37)

Rb-86 7E-5 2E-5 Rb-87 I E-4 2E-4 Ruthenium (44)

Ru-97 4E-4 3E-4 Ru-103 8E-5 8E-5 Ru-105 IE-4 IE-4 Ru-106 IE-5 IE-5 Samarium (62)

Sm-147 6E-5 7E-5 Sm-151 4E-4 4E-4 Sm-153 8E-5 8E-5 Scandium (21)

Sc-46 4E-5 4E-5 Sc-47 9E-5 9E-5 Sc-48 3E-5 3E-5 Selenium (34)

Se-75 3E-4 3E-4 Silicon (14)

Si-31 9E-4 2E-4 Silver (47)

Ag-105 IE-4 IE-4 Ag-I 1lOm 3E-5 3E-5 Ag-I I I 4E-5 4E-S Sodium (11)

Na-22 4E-5 3E-S Na-24 2E-4 3E-5 Strontium (38)

Sr-85m 7E-3 7E-3 Sr-85 I E-4 2E-4 Sr-89 3E-6 3E-5 Sr-90 3E-7 4E-5 Sr-91 7E-5 5E-5 Sr-92 7E-5 6E-5 Sulfur (16)

S-35 6E-5 31E-4 Tantalum (73)

Ta-182 4E-5 4E-5

Table F-I (Continued)

Element Isotope Soluble Conc.

Insoluble Conc.

(PCi/ml)

(PCi/ml)

Technetium (43)

Tc-96m IE-2 IE-2 Tc-96 I E-4 5E-5 Tc-97m 4E-4 2E-4 Tc-97 2E-3 8E-4 Tc-99m 6E-3 3E-3 Tc-99 3E-4 2E-4 Tellurium (52)

Te-125m 2E-4 IE-4 Te-127m 6E-5 SE-5 Te-127 3E-4 2E-4 Te-129m 3 E-5 2E-5 Te-129 8E-4 8E-4 Te-131 m 6E-S 4E-5 Te-132 3E-5 2E-5 Terbium (65)

Tb-160 4E-5 4E-5 Thallium (81)

TI-200 4E-4 2E-4 TI-201 3E-4 2E-4 TI-202 I E-4 7E-5 TI-204 I E-4 6E-5 Thorium (90)

Th-227 2E-5 2E-5 Th-228 7E-6 I E-5 Th-230 2E-6 3E-5 Th-231 2E-4 2E-4 Th-232 2E-6 4E-5 Th-natural 2E-6 2E-5 Th-234 2E-5 2E-5 Thulium (69)

Tm-170 SE-S 5E-S

-- nTm-171 5E-4 5E-4 Tin (50)

Sn-1 13 9E-5 8E-5 Sn-124 2E-5 2E-5 Tungsten (74)

W-181 4E-4 3E-4 W-185 I E-4 I E-4 W-187 7E-5 6E-5 U ranium (92)

U-230 5E-6 5E-6 U-232 3E-5 3E-5 U-233 3E-5 3E-5 U-234 3E-5 3E-S U-IZJD 3E-5 IP-5; 3E-I U-236 U-238 U-240 U-natural 3E-S 3E-5 3E-I 4E-5 3E-5 3E-5 4E-5 3E-5 3E-5

Table F-I (Continued)

Element Isotope Soluble Conc.o Insoluble Conc.

(pCi/ml)

(PCi/ml)

Vanadium (23)

V-48 3E-5 3E-5 Ytterbium (70)

Yb-175 IE-4 IE-4 Yttrium Y-90 2E-5 2E-5 Y-91m 3E-3 3E-3 Y-91 3E-5 3E-5 Y-92 6E-5 6E-5 Y-93 3E-5 3E-5 Zinc (30)

Zn-65 IE-4 2E-4 Zn-69m 7E-5 6E-5 Zn-69 2E-3 2E-3 Zirconium (40)

Zr-93 8E-4 8E-4 Zr-95 6E-5 6E-5 Zr-97 2E-5 2E-5 Any single radio-3E-6 3E-6 nuclide not listed above with decay mode other than alpha emission or spontaneous fission and with radio - active half-life greater than 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> Any single radio-3E-8 3E-8 nuclide not listed above. which decays by alpha emission or spontaneous fission.

Notes:

1. II the ideniil\\ of an radionuclide is not known, the limiting values for purposes of this table shall be: 3E-8 pCi/mI.

2 I tihe identl)i and concentration of each radionuclide are known, the limiting values should be derived as follows: Determine.

ror each radionuclide in the mixture. the ratio between the quantity present in the mixture and the limit otherwise established in Appendix 13 for the specific radionuclide not in a mixture. The sum of such ratios for all the radionuclides in the mixture mi-a! not exceed I (i.e. "unity").