MONTHYEARML1011601822010-04-16016 April 2010 St. Lucie Unit 1 License Amendment Request for Extended Power Uprate Project stage: Request L-2010-181, Withdrawal of Extended Power Uprate License Amendment Request2010-08-13013 August 2010 Withdrawal of Extended Power Uprate License Amendment Request Project stage: Withdrawal ML1035604192010-11-22022 November 2010 St. Lucie, Unit 1 - Transmittal of Affidavits from Westinghouse, Areva and Caldon Ultrasonica Technology Center Re License Amendment Request for Extended Power Uprate Project stage: Request L-2010-302, License Amendment Request for Extended Power Uprate2010-12-15015 December 2010 License Amendment Request for Extended Power Uprate Project stage: Request ML1107302822011-02-25025 February 2011 St. Lucie, Unit 2 - License Amendment Request for Extended Power Uprate, Attachment 2; Supplemental Environmental Report Project stage: Supplement ML1107302992011-02-25025 February 2011 St. Lucie, Unit 2 - License Amendment Request for Extended Power Uprate, Attachment 5; Licensing Report Project stage: Request ML1107301162011-02-25025 February 2011 St. Lucie, Unit 2 - License Amendment Request for Extended Power Uprate Project stage: Request ML1105906632011-03-0909 March 2011 Acceptance for Review of License Amendment Request for Extended Power Uprate Project stage: Acceptance Review ML1110100982011-04-19019 April 2011 Request for Additional Information Regarding License Amendment Request for Extended Power Uprate Project stage: RAI ML1113200042011-05-12012 May 2011 EPU - Supplemental Information Needed for Acceptance of Requested Licensing Action Amendment Project stage: Acceptance Review ML11153A0482011-05-27027 May 2011 St. Lucie Plant, Unit 1 - Information Regarding Areva LOCA and Non-LOCA Methodologies Provided in Support of the License Amendment Request for Extended Power Uprate Project stage: Request NRC-2011-0128, St. Lucie, Unit 1 - Notice of Consideration of Issuance of Amendment to Facility Operating License, and Opportunity for a Hearing and Order Imposing Procedures for Documents Access to Sensitive Unclassified Nonsafeguards Information2011-06-0202 June 2011 St. Lucie, Unit 1 - Notice of Consideration of Issuance of Amendment to Facility Operating License, and Opportunity for a Hearing and Order Imposing Procedures for Documents Access to Sensitive Unclassified Nonsafeguards Information Project stage: Approval ML11119A0852011-06-0202 June 2011 Notice of Consideration of Issuance of Amendment to Facility Operating License, and Opportunity for a Hearing and Order Imposing Procedures for Documents Access to Sensitive Unclassified Nonsafeguards Information Project stage: Other ML11119A0842011-06-0808 June 2011 Transmittal Letter - Notice of Consideration of Issuance of Amendment to Facility Operating License and Opportunity for a Hearing and Order Imposing Procedures for Document Access to Sensitive Unclassified Non Safeguards Information Project stage: Other ML11173A1042011-06-23023 June 2011 Acceptance for Review of License Amendment Request for Extended Power Uprate Project stage: Acceptance Review ML12037A1472011-07-21021 July 2011 NRR E-mail Capture - Efh Species for St. Lucie Project stage: Request L-2011-273, Information Regarding Anticipated Transients Without Scram (ATWS) Provided in Support of the Extended Power Uprate License Amendment Request2011-07-22022 July 2011 Information Regarding Anticipated Transients Without Scram (ATWS) Provided in Support of the Extended Power Uprate License Amendment Request Project stage: Request L-2011-314, Response to NRC Accident Dose Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request2011-08-12012 August 2011 Response to NRC Accident Dose Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request Project stage: Request NRC-2011-0190, St. Lucie Nuclear Plant, Units 1 and 2 - Federal Register Notice - Notice of Consideration of Issuance of Amendment to Facility Operating License, and Opportunity for a Hearing and Order Imposing Procedures for Document Access to SUNSI2011-08-26026 August 2011 St. Lucie Nuclear Plant, Units 1 and 2 - Federal Register Notice - Notice of Consideration of Issuance of Amendment to Facility Operating License, and Opportunity for a Hearing and Order Imposing Procedures for Document Access to SUNSI Info Project stage: Approval ML11208B6442011-08-26026 August 2011 Federal Register Notice - Notice of Consideration of Issuance of Amendment to Facility Operating License, and Opportunity for a Hearing and Order Imposing Procedures for Document Access to SUNSI Information Project stage: Other ML11208B6422011-09-0101 September 2011 Transmittal Letter - Notice of Consideration of Issuance of Amendment to Facility Operating License, and Opportunity for a Hearing and Order Imposing Procedures for Document Access to SUNSI Information Project stage: Other ML1123602302011-09-0202 September 2011 Request for Concurrence on List of Species with Essential Fish Habitat in the Vicinity of the St. Lucie Plant, Units 1 and 2 Project stage: Other L-2011-360, Response to NRC Accident Dose Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request2011-09-0202 September 2011 Response to NRC Accident Dose Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request Project stage: Request L-2011-397, Unusual or Important Environmental Event - Reportable Fish Kill2011-09-20020 September 2011 Unusual or Important Environmental Event - Reportable Fish Kill Project stage: Request L-2011-389, Response to NRC Reactor Systems Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request2011-09-22022 September 2011 Response to NRC Reactor Systems Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request Project stage: Request L-2011-383, Response to NRC Containment and Ventilation Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request2011-09-22022 September 2011 Response to NRC Containment and Ventilation Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request Project stage: Request L-2011-410, Environmental Protection Plan Report 316(b) Related Documentation2011-09-30030 September 2011 Environmental Protection Plan Report 316(b) Related Documentation Project stage: Request L-2011-404, Response to NRC Accident Dose Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request2011-10-0505 October 2011 Response to NRC Accident Dose Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request Project stage: Request L-2011-422, Response to NRC Reactor Systems Branch and Nuclear Performance Branch Request for Additional Information and Supplemental Information Regarding Extended Power Uprate License Amendment Request2011-10-10010 October 2011 Response to NRC Reactor Systems Branch and Nuclear Performance Branch Request for Additional Information and Supplemental Information Regarding Extended Power Uprate License Amendment Request Project stage: Supplement L-2011-450, Submittal of Final Revised Industrial Wastewater Facility Permit No. FL0002208, and Environmental Protection Plan Report2011-10-20020 October 2011 Submittal of Final Revised Industrial Wastewater Facility Permit No. FL0002208, and Environmental Protection Plan Report Project stage: Request L-2011-448, Response to NRC Reactor Systems Branch and Nuclear Performance Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request2011-10-31031 October 2011 Response to NRC Reactor Systems Branch and Nuclear Performance Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request Project stage: Request L-2011-466, Revision to Extended Power Uprate License Amendment Request Proposed Technical Specification 5.6, Design Features - Fuel Storage - Criticality2011-11-0404 November 2011 Revision to Extended Power Uprate License Amendment Request Proposed Technical Specification 5.6, Design Features - Fuel Storage - Criticality Project stage: Request L-2011-467, Response to NRC Accident Dose Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request2011-11-14014 November 2011 Response to NRC Accident Dose Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request Project stage: Request L-2011-493, Response to NRC Reactor Systems Branch and Nuclear Performance Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request2011-11-23023 November 2011 Response to NRC Reactor Systems Branch and Nuclear Performance Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request Project stage: Request L-2011-524, Response to NRC Steam Generator Tube Integrity and Chemistry Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request2011-12-27027 December 2011 Response to NRC Steam Generator Tube Integrity and Chemistry Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request Project stage: Request ML11332A0212011-12-28028 December 2011 Federal Register Notice - Draft Environmental Assessment and Draft Finding of No Significant Impact Related to the Proposed Extended Power Uprate Project stage: Request ML11332A0202011-12-28028 December 2011 Transmittal Letter - Draft Environmental Assessment and Draft Finding of No Significant Impact Related to the Proposed Extended Power Uprate Project stage: Draft Other L-2011-533, Response to NRC Reactor System Branch and Nuclear Performance Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request2011-12-29029 December 2011 Response to NRC Reactor System Branch and Nuclear Performance Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request Project stage: Request L-2011-566, Response to NRC Instrumentation & Controls Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request2012-01-14014 January 2012 Response to NRC Instrumentation & Controls Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request Project stage: Request L-2011-532, Response to NRC Reactor Systems Branch and Nuclear Performance Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request2012-01-14014 January 2012 Response to NRC Reactor Systems Branch and Nuclear Performance Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request Project stage: Request L-2011-565, Response to NRC Instrumentation & Controls Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request2012-01-14014 January 2012 Response to NRC Instrumentation & Controls Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request Project stage: Request L-2011-441, Response to NRC Reactor Systems Branch and Nuclear Performance Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request2012-01-18018 January 2012 Response to NRC Reactor Systems Branch and Nuclear Performance Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request Project stage: Request L-2011-534, Response to NRC Reactor System Branch and Nuclear Performance Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request2012-01-18018 January 2012 Response to NRC Reactor System Branch and Nuclear Performance Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request Project stage: Request L-2012-012, Response to NRC Reactor Systems Branch and Nuclear Performance Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request2012-01-21021 January 2012 Response to NRC Reactor Systems Branch and Nuclear Performance Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request Project stage: Request L-2012-009, Response to NRC Reactor System Branch and Nuclear Performance Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request2012-01-21021 January 2012 Response to NRC Reactor System Branch and Nuclear Performance Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request Project stage: Request L-2012-043, Comment (1) of Richard L. Anderson, on Behalf of Florida Power & Light, Regarding Draft Environmental Assessment and Draft Finding of No Significant Impact Related the Proposed Extended Power Uprate2012-01-30030 January 2012 Comment (1) of Richard L. Anderson, on Behalf of Florida Power & Light, Regarding Draft Environmental Assessment and Draft Finding of No Significant Impact Related the Proposed Extended Power Uprate Project stage: Draft Other ML12044A1272012-02-13013 February 2012 Comment (2) from Edward W. Johnson Opposing Ncr Permit Approval for St. Lucie 1 & 2 Project stage: Request L-2012-059, Response to NRC Mechanical and Civil Engineering Branch (Emcb) Request for Additional Information Regarding Extended Power Uprate License Amendment Request2012-02-29029 February 2012 Response to NRC Mechanical and Civil Engineering Branch (Emcb) Request for Additional Information Regarding Extended Power Uprate License Amendment Request Project stage: Request L-2012-075, Response to NRC Mechanical and Civil Engineering Branch (Emcb) Request for Additional Information Regarding Extended Power Uprate License Amendment Request2012-03-0606 March 2012 Response to NRC Mechanical and Civil Engineering Branch (Emcb) Request for Additional Information Regarding Extended Power Uprate License Amendment Request Project stage: Request L-2012-100, Response to NRC Reactor Systems Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request2012-03-0606 March 2012 Response to NRC Reactor Systems Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request Project stage: Request 2011-05-27
[Table View] |
|
---|
Category:Letter type:L
MONTHYEARL-2024-010, Point Units 3 and 4, Seabrook, Duane Arnold, and Point Beach Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3)2024-01-25025 January 2024 Point Units 3 and 4, Seabrook, Duane Arnold, and Point Beach Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3) L-2024-004, Relief Request (RR) 7, Proposed Alternative in Accordance with 10 CFR 50.55a(z)(1) Extension of Inspection Interval for Reactor Pressure Vessel Welds from 10 to 20 Years2024-01-18018 January 2024 Relief Request (RR) 7, Proposed Alternative in Accordance with 10 CFR 50.55a(z)(1) Extension of Inspection Interval for Reactor Pressure Vessel Welds from 10 to 20 Years L-2024-002, Withdrawal of Proposed Alternative to American Society of Mechanical Engineers (ASME) Operation and Maintenance (OM) Code for the Auxiliary Feedwater (AFW) 2C Pump2024-01-0808 January 2024 Withdrawal of Proposed Alternative to American Society of Mechanical Engineers (ASME) Operation and Maintenance (OM) Code for the Auxiliary Feedwater (AFW) 2C Pump L-2023-173, Quality Assurance Topical Report (FPL-1) Revision 30 Update2023-12-15015 December 2023 Quality Assurance Topical Report (FPL-1) Revision 30 Update L-2023-179, Unusual or Important Environmental Event - Turtle Mortality2023-12-14014 December 2023 Unusual or Important Environmental Event - Turtle Mortality L-2023-168, License Amendment Request Supplement to Revision 2 for the Technical Specifications Conversion to NUREG-1432 Revision 52023-12-12012 December 2023 License Amendment Request Supplement to Revision 2 for the Technical Specifications Conversion to NUREG-1432 Revision 5 L-2023-155, Supplement to Response to Request for Additional Information, Revised NextEra Common Emergency Plan, and Revised Site-Specific Emergency Plan Annexes Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-06542023-11-28028 November 2023 Supplement to Response to Request for Additional Information, Revised NextEra Common Emergency Plan, and Revised Site-Specific Emergency Plan Annexes Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, L-2023-162, Response to 50.69 2nd Round of Rals2023-11-21021 November 2023 Response to 50.69 2nd Round of Rals L-2023-131, Subsequent License Renewal Application - Second Annual Update2023-09-28028 September 2023 Subsequent License Renewal Application - Second Annual Update L-2023-136, Supplement to License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors2023-09-26026 September 2023 Supplement to License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors L-2023-122, Corrections to the 2022 Annual Radiological Environmental Operating Report2023-09-20020 September 2023 Corrections to the 2022 Annual Radiological Environmental Operating Report L-2023-127, Correction to the 2022 Annual Radioactive Effluent Release Report2023-09-18018 September 2023 Correction to the 2022 Annual Radioactive Effluent Release Report L-2023-113, Correction to the 2020 Annual Radiological Environmental Operating Report2023-09-14014 September 2023 Correction to the 2020 Annual Radiological Environmental Operating Report L-2023-118, Response to Request for Additional Information Regarding License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors2023-09-11011 September 2023 Response to Request for Additional Information Regarding License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors L-2023-108, Report of 10 CFR 50.59 Plant Changes2023-09-11011 September 2023 Report of 10 CFR 50.59 Plant Changes L-2023-112, Corrections to the 2021 Annual Radioactive Effluent Release Report2023-09-0606 September 2023 Corrections to the 2021 Annual Radioactive Effluent Release Report L-2023-107, Technical Specification Bases Control Program Periodic Report of Bases Changes TS 6.8.4.j.42023-09-0606 September 2023 Technical Specification Bases Control Program Periodic Report of Bases Changes TS 6.8.4.j.4 L-2023-114, Proposed Turkey Point Units 6 and 7; Seabrook Station; Point Beach Units 1 and 2 - Official Service List Update2023-08-17017 August 2023 Proposed Turkey Point Units 6 and 7; Seabrook Station; Point Beach Units 1 and 2 - Official Service List Update L-2023-098, and Point Beach Units 1 and 2 - Response to Request for Additional Information Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 22023-08-0707 August 2023 and Point Beach Units 1 and 2 - Response to Request for Additional Information Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 2 L-2023-105, Preparation and Scheduling of Operator Licensing Examinations2023-08-0303 August 2023 Preparation and Scheduling of Operator Licensing Examinations L-2023-099, Pump Relief Request 10 (PR-10), One-Time Request for an Alternative to the American Society of Mechanical Engineers (ASME) Operation and Maintenance (OM) Code for the Auxiliary Feedwater (AFW) 2C Pump2023-07-26026 July 2023 Pump Relief Request 10 (PR-10), One-Time Request for an Alternative to the American Society of Mechanical Engineers (ASME) Operation and Maintenance (OM) Code for the Auxiliary Feedwater (AFW) 2C Pump L-2023-102, Relief Request PSL2-15-RR-01, Proposed Alternative to ASME Section XI Code Examination Requirements for Reactor Vessel Bottom Area and Piping in Covered Trenches2023-07-26026 July 2023 Relief Request PSL2-15-RR-01, Proposed Alternative to ASME Section XI Code Examination Requirements for Reactor Vessel Bottom Area and Piping in Covered Trenches L-2023-097, Subsequent License Renewal Application Revision 1 - Supplement 62023-07-13013 July 2023 Subsequent License Renewal Application Revision 1 - Supplement 6 L-2023-076, In-Service Inspection Program Owner'S Activity Report (OAR-1)2023-07-11011 July 2023 In-Service Inspection Program Owner'S Activity Report (OAR-1) L-2023-087, Florida Power & Light/Nextera Energy, Results of the Safety Culture Program Effectiveness Review, March 20, 2023 (ADAMS Accession No. ML22340A452)2023-06-29029 June 2023 Florida Power & Light/Nextera Energy, Results of the Safety Culture Program Effectiveness Review, March 20, 2023 (ADAMS Accession No. ML22340A452) L-2023-082, Subsequent License Renewal Application Revision 1, Supplement 52023-06-14014 June 2023 Subsequent License Renewal Application Revision 1, Supplement 5 L-2023-074, Addendum to 2021 Decommissioning Funding Status Reports / Independent Spent Fuel Storage Installation Ctsfsi) Financial Assurance Update2023-06-0202 June 2023 Addendum to 2021 Decommissioning Funding Status Reports / Independent Spent Fuel Storage Installation Ctsfsi) Financial Assurance Update L-2023-071, NextEra Energy Quality Assurance Topical Report (FPL-1) Revision 29 and Florida Power and Light Company Quality Assurance Program Description for 10 CFR Part 52 Licenses (FPL-2) Revision 11, Annual Submittal2023-05-22022 May 2023 NextEra Energy Quality Assurance Topical Report (FPL-1) Revision 29 and Florida Power and Light Company Quality Assurance Program Description for 10 CFR Part 52 Licenses (FPL-2) Revision 11, Annual Submittal L-2023-059, Subsequent License Renewal Application - Aging Management Requests for Additional Information (RAI) Set 4 Supplemental Response2023-04-21021 April 2023 Subsequent License Renewal Application - Aging Management Requests for Additional Information (RAI) Set 4 Supplemental Response L-2023-055, 2022 Annual Environmental Operating Report2023-04-12012 April 2023 2022 Annual Environmental Operating Report L-2023-041, Annual Radiological Environmental Operating Report for Calendar Year 20222023-04-0404 April 2023 Annual Radiological Environmental Operating Report for Calendar Year 2022 L-2023-051, Report of 10 CFR 50.59 Plant Changes2023-04-0404 April 2023 Report of 10 CFR 50.59 Plant Changes L-2023-021, Units, 1 and 2, Turkey Point, Units 3 and 4, Seabrook Station and Point Beach, Units 1 and 2 - Decommissioning Funding Status Reports / Independent Spent Fuel Storage Installation (ISFSI) Financial Assurance Update2023-03-28028 March 2023 Units, 1 and 2, Turkey Point, Units 3 and 4, Seabrook Station and Point Beach, Units 1 and 2 - Decommissioning Funding Status Reports / Independent Spent Fuel Storage Installation (ISFSI) Financial Assurance Update L-2023-042, Periodic Update of Population Data within 10 and 50 Miles of the Plant2023-03-27027 March 2023 Periodic Update of Population Data within 10 and 50 Miles of the Plant L-2023-026, Subsequent License Renewal Application - Aging Management Requests for Additional Information Set 42023-03-27027 March 2023 Subsequent License Renewal Application - Aging Management Requests for Additional Information Set 4 L-2023-028, and Point Beach Units 1 and 2, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications2023-03-27027 March 2023 and Point Beach Units 1 and 2, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications L-2023-025, Fleet Relief Request (Frr) 23-01, Proposed Alternative to ASME Section XI Authorizing Implementation of ASME Code Case N-752-12023-03-15015 March 2023 Fleet Relief Request (Frr) 23-01, Proposed Alternative to ASME Section XI Authorizing Implementation of ASME Code Case N-752-1 L-2023-029, and Point Beach Units 1 and 2 Nuclear Property Insurance - 10 CFR 50.54(w)(3)2023-03-10010 March 2023 and Point Beach Units 1 and 2 Nuclear Property Insurance - 10 CFR 50.54(w)(3) L-2023-039, Cycle 27 Core Operating Limits Report2023-03-0707 March 2023 Cycle 27 Core Operating Limits Report L-2023-032, 2022 Annual Radioactive Effluent Release Report2023-02-28028 February 2023 2022 Annual Radioactive Effluent Release Report L-2023-038, 2022 Annual Operating Report2023-02-28028 February 2023 2022 Annual Operating Report L-2023-016, Radiological Emergency Plan - Revision 74 Report of Changes to Emergency Plan2023-02-15015 February 2023 Radiological Emergency Plan - Revision 74 Report of Changes to Emergency Plan L-2023-019, Annual Summary of Commitment Changes Implemented Without Prior NRC Notification for Calendar Year 20222023-02-15015 February 2023 Annual Summary of Commitment Changes Implemented Without Prior NRC Notification for Calendar Year 2022 L-2023-009, Owner'S Activity Report2023-01-31031 January 2023 Owner'S Activity Report L-2022-188, Unusual or Important Environmental Event - Turtle Mortality2022-12-19019 December 2022 Unusual or Important Environmental Event - Turtle Mortality L-2022-185, Turkey Points, Units 3 & 4; Seabrook Station; and Point Beach, Units 1 and 2 - Supplement to License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 22022-12-0909 December 2022 Turkey Points, Units 3 & 4; Seabrook Station; and Point Beach, Units 1 and 2 - Supplement to License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 2 L-2022-175, Application to Adopt 10 CPR 50.69, 'Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors2022-12-0202 December 2022 Application to Adopt 10 CPR 50.69, 'Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors L-2022-180, CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums2022-11-0909 November 2022 CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums L-2022-165, Subsequent License Renewal Application - Aging Management Request for Additional Information (RAI) 4.3.1-1a(second Round) - Class 1 Fatigue Response2022-10-26026 October 2022 Subsequent License Renewal Application - Aging Management Request for Additional Information (RAI) 4.3.1-1a(second Round) - Class 1 Fatigue Response L-2022-160, Station,, Point Beach Units 1 and 2, License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 22022-10-0404 October 2022 Station,, Point Beach Units 1 and 2, License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 2 2024-01-08
[Table view] |
Text
Florida Power &Light Company, 6501 South Ocean Drive, Jensen Beach, FL 34957 FPL. May 2, 2012 L-2012-199 10 CFR 50.90 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Re: ST. LUCIE PLANT, UNITS 1 AND 2-DRAFT ENVIRONMENTAL ASSESSMENT AND DRAFT FINDING OF NO SIGNIFICANT IMPACT RELATED TO THE PROPOSED EXTENDED POWER UPRATE (TAC NOS. ME5091 AND ME5843)
Docket ID: NRC-2011-0302 Docket Nos. 50-335 and 50-389 License Nos. DPR-67 and NPF-16
References:
(1) Richard L. Anderson (FPL) to U.S. Nuclear Regulatory Commission (L-2010-259),
"License Amendment Request for Extended Power Uprate," St. Lucie Unit 1, November 22, 2010, Accession No. ML103560419.
(2) Richard L. Anderson (FPL) to U.S. Nuclear Regulatory Commission (L-2011-021),
"License Amendment Request for Extended Power Uprate," St Lucie Unit 2, February 25, 2011, Accession No. ML110730116.
(3) Tracy J. Orf (NRC) to Mano Nazar (FPL), "ST. LUCIE PLANT, UNITS 1 AND 2-DRAFT ENVIRONMENTAL ASSESSMENT AND DRAFT FINDING OF NO SIGNIFICANT IMPACT RELATED TO THE PROPOSED EXTENDED POWER UPRATE (TAC NOS. ME5091 AND ME5843)," December 28, 2011.
(4) Richard L. Anderson (FPL) to Cindy Bladey, Chief, Rules, Announcements, and Directives Branch (L-2012-043), ST. LUCIE PLANT, UNITS 1 AND 2-DRAFT ENVIRONMENTAL ASSESSMENT AND DRAFT FINDING OF NO SIGNIFICANT IMPACT RELATED TO THE PROPOSED EXTENDED POWER UPRATE (TAC NOS. ME5091 AND ME5843), January 30, 2012 Accession No. ML12037A063.
(5) Email from T. Orf (NRC) to C. Wasik (FPL), "St. Lucie 1/2 EPU environmental assessment question," April 18, 2012.
On November 22, 2010 [Reference 1] and February 25, 2011 [Reference 2], Florida Power & Light Company (FPL) submitted license amendment requests (LARs) to the Nuclear Regulatory Commission (NRC) requesting amendments to the St. Lucie Unit 1 and St. Lucie Unit 2 renewed operating licenses (DPR-67 and NPF-16), respectively, requesting authorization to increase licensed core thermal power and implement an Extended Power Uprate.
an FPL Group company
L-2012-199 Page 2 of 2 By letter dated December 28, 2011 [Reference 3], the NRC Office of Nuclear Reactor Regulation forwarded to FPL, a copy of the "Draft Environmental Assessment and Draft Finding of No Significant Impact Related to the Proposed License Amendment to Increase the Maximum Reactor Power Level" for St. Unit 1 and Unit 2. The NRC also forwarded a copy of this draft document to the Office of the Federal Register for publication.
By letter dated January 30, 2012 [Reference 4], FPL provided comments on the NRC's Draft Environmental Assessment and Draft Finding of No Significant Impact. FPL comment number 2 in the Reference 4 letter discussed an increase in the number of EPU construction workers over the number of EPU construction workers identified in the NRC's Environmental Assessment.
By email from the NRC Project Manager dated April 18, 2012 [Reference 5], additional information was requested by NRC staff regarding FPL's comment number 2 in the Reference 4 letter. The request for additional information (RAI) identified six questions.
The response to these six questions is provided in the attachment to this letter.
In accordance with 10 CFR 50.91 (b)(1), a copy of this letter is being forwarded to the designated State of Florida official.
Should you have any questions regarding this submittal, please contact Mr. Christopher Wasik, St. Lucie Extended Power Uprate LAR Project Manager, at 772-467-7138.
I declare under penalty of perjury that the foregoing is true and correct to the best of my knowledge.
Executed on o2-/"9,4 ,go I Sincerely, Richard L. An erson Site Vice President St. Lucie Plant Attachment (1) cc: Mr. William Passetti, Florida Department of Health, Bureau of Radiation Control
L-2012-199 Attachment Page 1 of 5 Response to NRC Request for Additional Information By letter dated January 30, 2012, FPL provided comments on the NRC's Draft Environmental Assessment and Draft Finding of No Significant Impact. FPL comment number 2 discussed an increase in the number of EPU construction workers over the number of EPU construction workers identified in the NRC's Environmental Assessment.
By email from the NRC Project Manager dated April 18, 2012, additional information was requested by NRC staff regarding FPL's comment number 2 in the January 30, 2012 FPL letter.
The request for additional information (RAI) identified six questions. The NRC's questions and FPL's responses are provided below.
In a comment submitted by FPL, the number of expected construction workers during the EPU was raised from a potential peak of 1,400 workers to a potential peak of 3,000 workers, with an estimated average number per outage of approximately 2,100. This new information raises a few questions in the areas of traffic, land use, and air quality. Please provide the NRC with the following information related to socioeconomic impacts:
Question I An estimate of the number of outages needed to implement the EPU, the expected length (days) of each EPU-related outage, and the average and peak numbers of workers expected at each individual outage.
Response
The St. Lucie Unit 1 and 2 EPU project will be executed over four refueling outages (two outages per unit) plus a mid-cycle implementation outage for Unit 1. Three of the four refueling outages have been completed and the fourth (Unit 2) is scheduled for fall of 2012 with an approximate duration of 113 days. In addition to the completed EPU refueling outages, Unit 1 will require a short "mid-cycle" outage of approximately 10 days in the summer of 2012 to implement the final EPU changes.
For the recently completed Unit 1 outage, the average number of EPU workers was 750, with a peak of 1703 workers. This number of EPU workers is consistent with the total number of outage workers as estimated in FPL's letter dated January 30, 2012 (Reference 4 to this letter).
For the planned Unit 1 mid-cycle outage, FPL expects to require little to no additional staff. The average number of EPU workers expected during the upcoming Unit 2 outage is 1058, with a peak of 1439 EPU workers expected. Thus, the total number of expected outage workers for the upcoming Unit 2 outage would be bounded by the total number of workers from the recent Unit 1 outage.
Per discussion with staff on April 25, 2012, additional historical outage information is not required for this response.
L-2012-199 Attachment Page 2 of 5 Question 2 A description of how FPL handles traffic conditions during shift changes on South Ocean Drive (1A) during normal refueling outages (including outages for major component replacements in the past) and whether anything will be done to accommodate the heavier than normal outage traffic conditions during the EPU related outage(s).
Response
FPL has three normal and one overflow parking lots with individual entry/exit points. One of these four lots is reserved for FPL employees. During normal refueling outages, no specific changes are employed to the parking lots or entry/exit points except that a parking attendant is used in the lot reserved for FPL employees to redirect contractors and vendors.
FPL will typically attempt to stagger shift start and stop times to minimize any impact of oncoming or off going shift changes. During major component replacement outages in the past, FPL established satellite parking lots and used busses to transport workers from the lots to the site.
In addition, FPL employed sheriff's officers staged on the south and north ends of the site to monitor and control traffic on State Road AlA. FPL is using a similar approach during the EPU outages. Busses are being used to transport workers from satellite parking lots to the site and sheriff's officers are being staged on the south and north ends of the site to monitor and control traffic on State Road AMA, to accommodate the heavier than normal outage traffic conditions during the EPU - related outage(s).
Question 3 Provide a copy of the transportation analysis that FPL's comment claims supports a no-significant-impacts finding.
Response
The analysis that was performed by FPL to assess the traffic impacts that would result from a projected increase in the number of workers reporting to the St. Lucie site during the EPU and determination of no significant impact is provided in the table below. FPL's transportation analysis used the same analytical techniques and calculations that were provided in Section 4.6.2 of the St. Lucie Uprate Project Site Certification Application (SCA), except, the Level of Service (LOS) values cited are from the Florida Department of Transportation (FDOT) Quality/Level of Service Handbook, 2009 rather than the values from 2007. The 2009 Handbook LOS D values are slightly higher than those provided in the SCA.
L-2012-199 Attachment Page 3 of 5 FPL St. Lucie EPU Traffic Calculations Site 940116 Site 940719 Average Average LOS LOS D 2007 Baseline 5,212 4,497 4,855 4,855 B 22,2100 2012 Projected 5,811 5,014 5,413 5,413 B 22,200 2012 w/Uprates 6,978 6,181 6,580 6,580 B 22,200 1,167 1,167 1,167 1,167 Workers 1,400 1.2 per vehicle 1,167 Vehicles per day (with 50% North and 50% South)
Site 940116 Site 940719 Average Average LOS LOS D 2007 Baseline 5,212 4,497 4,855 4,855 8 22,200 2012 Projected 5,811 5,014 5,413 5,413 B 22,200 2012 w/Uprates 8,311 7,514 7,913 7,913 C or Better 22,200 2,500 2,500 2,500 2,500 Workers 3,000 1.2 per vehicle 2,500 Vehicles per day (with 50% North and 50% South)
LOS based on 2009 FOOT Quality/Level of Service Handbook Note: LOS C is >7,800 and </= to 15,600 LOS D is >15,600 and </= 22,200 Question 4 Descriptions of any onsite land use changes, including additional or expanded parking areas that may be needed to accommodate the expanded EPU-related construction workforce.
Response
During the EPU related refueling outages, FPL added two additional overflow parking areas/facilities as well as safe walk pathways, additional lighting and signage. Area 1 is located at the south end of the owner controlled area, north of the intake canal and just west of the current "overflow" lot. Area 1 is a vacant area that was prepared by grading and adding parking stops. Area 2 is located on the south side of the intake canal on the access road to the west property and recreation areas. Area 2 required some minor grubbing, grading and set-up to accommodate overflow parking. New lighting, safe walkways and signage were also required as well as establishing a shuttle bus service for transportation to the plant.
L-2012-199 Attachment Page 4 of 5 The additional parking facilities are located on previously disturbed areas of the plant site (e.g.,
existing dirt lot, recreation fields and areas immediately adjacent-to the access road). Prior to preparing the additional parking, FPL performed a survey of the area in accordance with the Site Conditions of Certification to identify potential impacts to threatened or endangered wildlife. EPU worked with plant Environmental Department personnel to ensure that any ecological and cultural resources were protected during the noted grubbing and grading activities. Permitting was not required. Best management practices have been employed to reduce fugitive emissions created by increased traffic in the unpaved overflow parking areas. Unpaved areas are routinely sprayed by a water truck to limit airborne dust created by traffic.
Question 5 A conformity assessment of the potential air quality effects from both the expected average of 2,100 commuting workers and the potential peak force of 3,000 workers.
Response
The projected increase in the number of construction workers that will be reporting to the St. Lucie plant during the EPU will be from 1,400 to 3,000 at the peak, with an increase in the average from 1,000 to 2,100. The increase will not change the conclusion provided in Section 4.5 of the St.
Lucie Uprate Project Site Certification Analysis that the project will not cause significant impacts to air quality in the vicinity of the St. Lucie plant.
Based on the traffic study performed for the project, the expected occupancy rate is 1.2 workers per vehicle or 20 percent of the workers carpool. As a result, 917 additional construction vehicles are estimated with a peak increase of 1,333. These workers would travel along State Road AlA traveling both north and south to the site.
The vehicles driven by construction workers will be traveling along State Road AlA to and from the St. Lucie plant, For vehicles, emissions of nitrogen oxides (NOx), carbon monoxide (CO), and volatile organic compounds (VOCs) are the primary air pollutants. NOx and VOCs are precursors of ozone; however, the potential impacts to air quality from ozone formation are not expected to be significant, nor exceed ambient air quality standards (AAQS) in the vicinity of the roadways or the St. Lucie plant site. The estimated emissions of NOx and VOCs would be less than 1000 grams/mile/day for the peak construction workers and average less than 650 grams/mile/day.
This level of air emissions would be negligible in the regional formation of ozone.
For CO, the estimated emissions would be less than 9,500 grams/mile/day for the peak construction workers and average less than 6,500 grams/mile/day. The AAQS for CO are 40,000 micrograms per cubic meter (ug/m 3) for a 1-hour average and 10,000 ug/m 3 for an 8-hour average (both standards not to be exceeded more than once per year). The direction of travel is primarily perpendicular to the primary wind direction. As a result any emissions will be dispersed laterally during travel. Using the average wind speed representative in the area the maximum increase in 1-hour CO concentration would be less than 100 ug/m 3 that is well less than AAQS. Given the short-term nature of the construction activities and limitation of worker travel, air emissions from construction activities and travel will cause very minor impacts to air quality in the vicinity of the St. Lucie plant boundary and along State Road AlA.
L-2012-199 Attachment Page 5 of 5 Vehicular traffic from the construction workers will result in emissions of particulate matter (PM) due to vehicles entering and leaving the St. Lucie plant. The entrance roads and the primary parking areas are paved, which minimizes dust emissions from vehicles entering the St. Lucie plant. Since much of the area used for construction parking and laydown is paved or over grass, fugitive emissions will be minimized. Paving and having grassed areas for parking is recognized as reasonable precautions by Florida Department of Environmental Protection (FDEP) Rule 62-296.320(4)(c) Florida Administrative Code in minimizing fugitive PM emissions. Even if all the additional construction workers travel and park in unpaved grassed areas, the annual PM emissions would be about 4 tons/year for the average increase in workers. The FDEP, for which its regulations are approved by EPA, recognizes in Rule 62-210.300(3)(b) F.A.C. that air emissions of less than 5 tons/year of PM do not require a permit and are considered insignificant.
As a result, the estimated fugitive PM emissions from the additional workers are not expected to significantly affect air quality.
Question 6 A determination whether this level of increase in outage-related traffic would not trigger air quality violations under the Clean Air Act.
Response
The temporary increase of air emissions resulting from outage related traffic will have a minimal impact on air quality and will not trigger air quality violations under the Clean Air Act. This is demonstrated by air monitoring data available in Palm Beach County located approximately 40 miles south of the St. Lucie plant. Palm Beach County has very similar meteorological conditions but is highly urbanized with a 2010 population of about 1.3 million [Florida Statistical Abstracts (FSA), 2011, University of Florida, Bureau of Economic and Business Research]. Air monitoring stations within the highly urbanized Palm Beach County demonstrate that the air quality in the County complies with the Ambient Air Quality Standards (AAQS) promulgated by EPA under the Clean Air Act and adopted by FDEP. This includes the air pollutant ozone for which vehicle emissions are precursors. In contrast, St. Lucie County is far less urbanized with a population of less than 0.3 million (FSA, 2011). In addition, there is an FDEP ozone monitoring station located approximately 3.3 miles northwest of the St. Lucie plant. Air quality observed at this St. Lucie County station is well less than the ozone AAQS.