IR 05000483/1988008

From kanterella
Jump to navigation Jump to search
Addendum to Insp Rept 50-483/88-08 Comparing Results of Analyses Performed on Liquid Spike & Monitor Tank Sample
ML20247K317
Person / Time
Site: Callaway 
Issue date: 07/21/1989
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML20247K287 List:
References
50-483-88-08, 50-483-88-8, NUDOCS 8907310510
Download: ML20247K317 (2)


Text

{{#Wiki_filter:- - _ _ _ - - _ _ _. _ .. % ~ I . .. - i . TABLE 2 U S NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT CONFIRMATORY MEASUREMENTS PROGRAM FACILITY: CALLAWAY FOR THE 2 OUARTER OF 1988


NRC-------

-LICENSEE---- ---LICENSEE NRC---- SAMPLE ISOTOPE RESULT ERROR RESULT ERROR RATIO RES T F SPIKED G BETA 1.7E-05 8.0E-07 1.8E-05 1.0E-06 1.1E 00 2.1E 01 A SR-89 5.4E-04 1.6E-05 5.5E-04 3.0E-05 1.OE 00 3.4E 01 A SR-90 3.3E-05 1.3E-06 2.BE-05 2.0E-06 B.5E-01 2.5E 01 A FE-55 7.1E-05 1.4E-06 6.4E-05 3.0E-06 9.0E-01 5.1E 01 A T TEST RESULTS: AsAGREEMENT DsDISAGREEMENT caCRITERIA RELAXED NANO COMPARISON I i l I s9073105{{ [[j,[3 bks 3 l PDR HDO FDC Q l i _ _ _ _ _ _ _ _ _ - _ - - _ - -. - - - - _. )

. 4-o ' '

. s ,

. & ATTACHMENT 1 . CRITERIA FOR COMPARING ANALYTICAL MEASUREMENTS , This attachment provides criteria for comparing results of capability tests , ' and verification measurements.

The criteria are based on an empirical relationship which combines prior experience and the accuracy needs of this program.

. - In these criteria, the judgment limits are variable in relation to the comparison of the NRC's value to its associated one sigma uncertainty.

As that ratio, referred to in this program as " Resolution", increases, the acceptability of a licensee's measurement should be more selective.

should be considered acceptable as the resolution decreases. Conversely, poorer agree The values in the ratio criteria may be rounded to fewer significant figures reported by the NRC Reference Laboratory, unless such rounding will result in a narrowed category of acceptance.

RESOLUTION RATIO = LICENSEE VALUE/NRC REFERENCE VALUE c5 Agreement <4 0.4 - 2.5 4-

0.5 - 2.0 8-

0.6 - 1.66 16 - 50 0.75 - 1.33 51 - 200 0.80 - 1.25 200 - 0.85 - 1.18 , Some discrepancies may result from the use of different equipment, techniques, and for some specific nuclides.

These may be factored into the acceptance criteria and identified on the data sheet.

.

e a _ - -. - _ - - _ _ - - - - - _. _ - -. _ _ _ _ - -. _ - - - _ }}