SUBJECT:

CLINTON POWER STATION - INTEGRATED INSPECTION REPORT 05000461/2025001

Dear David Rhoades:

On March 31, 2025, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Clinton Power Station. On April 17, 2025, the NRC inspectors discussed the results of this inspection with Andy Krukowski and other members of your staff. The results of this inspection are documented in the enclosed report.

No findings or violations of more than minor significance were identified during this inspection.

This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.

Sincerely, Robert Ruiz, Chief Reactor Projects Branch 1 Division of Operating Reactor Safety Docket No. 05000461 License No. NPF-62

Enclosure:

As stated

Inspection Report

Docket Number:

05000461

License Number:

NPF-62

Report Number:

05000461/2025001

Enterprise Identifier:

I-2025-001-0063

Licensee:

Constellation Nuclear

Facility:

Clinton Power Station

Location:

Clinton, IL

Inspection Dates:

January 01, 2025, to March 31, 2025

Inspectors:

T. Hartman, Senior Project Engineer

A. Muneeruddin, Senior Resident Inspector

J. Murphy, Illinois Emergency Management Agency

J. Steward, Senior Resident Inspector

Approved By:

Robert Ruiz, Chief

Reactor Projects Branch 1

Division of Operating Reactor Safety

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting an integrated inspection at Clinton Power Station, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors. Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.

List of Findings and Violations

No findings or violations of more than minor significance were identified.

Additional Tracking Items

None.

PLANT STATUS

Unit 1 began the inspection period at rated thermal power (RTP). On March 8, 2025, Unit 1 lowered reactor power to 72 percent RTP to perform a planned control rod sequence exchange, and settle testing on two control rods, 52-21 and 04-37. Following completion of the sequence exchange and settle testing on March 9, 2025, the unit was returned to RTP and continued to operate at or near RTP for the remainder of the inspection period.

INSPECTION SCOPES

Inspections were conducted using the appropriate portions of the inspection procedures (IPs)in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2515, Light-Water Reactor Inspection Program - Operations Phase. The inspectors performed activities described in IMC 2515, Appendix D, Plant Status, observed risk significant activities, and completed on-site portions of IPs. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.

REACTOR SAFETY

71111.01 - Adverse Weather Protection

Impending Severe Weather Sample (IP Section 03.02) (1 Sample)

(1) The inspectors evaluated the adequacy of the overall preparations to protect risk-significant systems from impending severe weather, specifically a cold weather alert with significant amount of snow greater than 5 inches on January 3, 2025.

71111.04 - Equipment Alignment

Partial Walkdown Sample (IP Section 03.01) (3 Samples)

The inspectors evaluated system configurations during partial walkdowns of the following systems/trains:

(1)standby liquid control train B on March 18, 2025 (2)residual heat removal train A on March 20, 2025 (3)division 2 battery and direct current distribution system on March 31, 2025

71111.05 - Fire Protection

Fire Area Walkdown and Inspection Sample (IP Section 03.01) (5 Samples)

The inspectors evaluated the implementation of the fire protection program by conducting a walkdown and performing a review to verify program compliance, equipment functionality, material condition, and operational readiness of the following fire areas:

(1) Fire Areas D-4(a) and D 4(b); division 3 diesel generator and day tank room on January 29, 2025
(2) Fire Areas 737' service building grade floor and 722' service building basement on February 3, 2025
(3) Fire Area A-3(f) 781' - 790' auxiliary building division 2 switchgear on March 18, 2025
(4) Fire Area A-2(h); 737' auxiliary building east outside of reactor water cleanup pump (RWCU) B room on March 18, 2025
(5) Fire Area A-2(b); residual heat removal train A pump and heat exchanger room on March 20, 2025

Fire Brigade Drill Performance Sample (IP Section 03.02) (1 Sample)

(1) The inspectors evaluated the onsite fire brigade training and performance during an announced fire drill outside the RWCU B Pump Room, 737' auxiliary building east on March 18, 2025.

71111.11Q - Licensed Operator Requalification Program and Licensed Operator Performance

Licensed Operator Performance in the Actual Plant/Main Control Room (IP Section 03.01) (1 Sample)

(1) The inspectors observed and evaluated licensed operator performance in the control room during a planned downpower to 72 percent RTP for rod settle testing on control rods 04-37 and 52-21, and a control rod sequence exchange on March 8, 2025.

Licensed Operator Requalification Training/Examinations (IP Section 03.02) (1 Sample)

(1) The inspectors observed and evaluated licensed operator requalification training performance in the simulator on February 4, 2025.

71111.13 - Maintenance Risk Assessments and Emergent Work Control

Risk Assessment and Management Sample (IP Section 03.01) (1 Sample)

The inspectors evaluated the accuracy and completeness of risk assessments for the following planned and emergent work activities to ensure configuration changes and appropriate work controls were addressed:

(1)elevated risk (action green) associated with invoking risk informed completion time (RICT) for the failure of division 4 main steam line pressure low instrument atm, 1B21-N676D, during a division 3 system outage work week, per action request (AR) 4841842 on March 4, 2025

71111.15 - Operability Determinations and Functionality Assessments

Operability Determination or Functionality Assessment (IP Section 03.01) (6 Samples)

The inspectors evaluated the licensees justifications and actions associated with the following operability determinations and functionality assessments:

(1)loss of the continuous containment exhaust ventilation system due to a configuration control event per AR 4829091 on January 17, 2025 (2)unexpected trip of residual heat removal (RHR) pump B and RHR C waterleg pump per AR 4832418 on January 28, 2025 (3)division 1 diesel generator 12-cylinder engine failed to trip from the 16-cylinder engine per AR 04836219 on February 14, 2025 (4)unexpected main control room annunciator for low steam line pressure per AR 04841842 on March 6, 2025 (5)standby liquid control A pump gearbox low level per ARs 4846842 and 4847101 on March 27, 2025 (6)345 KV and 138 KV bus voltage spikes and resultant impact on offsite power source operability per AR 4841480 on March 27, 2025

71111.24 - Testing and Maintenance of Equipment Important to Risk

The inspectors evaluated the following testing and maintenance activities to verify system operability and/or functionality:

Post-Maintenance Testing (PMT) (IP Section 03.01) (9 Samples)

(1)suppression pool cleanup pump A corrective maintenance and return to service testing per work order (WO) 5587356 tasks 01, 02 and 05 on January 14, 2025 (2)replacement and testing of the 1WX020 handswitch, RWCU backwash outboard isolation valve hand switch following failure per WO 5615967-06, on January 30, 2025 (3)overspeed trip test of division 1 diesel generator, 12-cylinder and 16-cylinder engines following adjustment of the overspeed mechanism spring adjustment per WO 05351114, on February 13, 2025 (4)remote shutdown panel 24 vdc inverter 1C61-K002 replacement following failure and post-maintenance test per WO 5627633 tasks, 01, 02 and 03 on March 5, 2025 (5)division 3 diesel generator governor control switch replacement and post-maintenance test per WO 05546925-01, on March 7, 2025 (6)post-maintenance test of fuel pool cooling and cleanup supply inside containment isolation valve, 1FC037 following thrust verification and motor operated valve clean and inspect per WO 05095397-04, on March 11, 2025 (7)high pressure core spray waterleg pump, 1E22-C003 post-maintenance testing following sampling and replacement of pump oil per WO 5557291-02, on March 24, 2025 (8)control room ventilation train B per WOs 5374901 and 5150307, on March 27, 2025 (9)control room chiller train B per WOs 5160391-03, 5195326-02, 5554803-03 and

5375841-02, on March 31, 2025 Surveillance Testing (IP Section 03.01)

(1) B primary containment recombiner and valve operability test per WO 05388725-01 and CPS 9068.03, on February 18, 2025

Inservice Testing (IST) (IP Section 03.01) (1 Sample)

(1) RHR B & C waterleg pump inservice testing of a new waterleg pump per CPS 9058.02, following unexpected failure of the original waterleg pump on February 6, 2025

Diverse and Flexible Coping Strategies (FLEX) Testing (IP Section 03.02) (1 Sample)

(1)semiannual functional testing (unloaded) and annual performance testing (loaded) of FLEX diesel generator 2, 1FX01KB, per WOs 05602483 and 05604614, on February 12, 2025

71114.06 - Drill Evaluation

Additional Drill and/or Training Evolution (1 Sample)

The inspectors evaluated:

(1) field monitoring team annual training on March 13,

OTHER ACTIVITIES - BASELINE

===71151 - Performance Indicator Verification The inspectors verified licensee performance indicators submittals listed below:

IE01: Unplanned Scrams per 7000 Critical Hours Sample (IP Section 02.01)===

(1)

(1) Unit 1 (January 1, 2024, through December 31, 2024)

IE03: Unplanned Power Changes per 7000 Critical Hours Sample (IP Section 02.02) (1 Sample)

(1)

(1) Unit 1 (January 1, 2024, through December 31, 2024)

IE04: Unplanned Scrams with Complications (USwC) Sample (IP Section 02.03) (1 Sample)

(1)

(1) Unit 1 (January 1, 2024, through December 31, 2024)

INSPECTION RESULTS

No findings were identified.

EXIT MEETINGS AND DEBRIEFS

The inspectors verified no proprietary information was retained or documented in this report.

  • On April 17, 2025, the inspectors presented the integrated inspection results to A. Krukowski and other members of the licensee staff.

DOCUMENTS REVIEWED

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

E02-1DC06 sheet

25 VDC & Uninterruptible Power Supply Systems

AE

E02-1DC99 sheet

25V DC MCC & Distribution Panel 1B Alarms &

Instrumentation

AK

M05-1075 sheet 1

Residual Heat Removal

AZ

M05-1075 sheet 4

Residual Heat Removal

AG

Drawings

M05-1077 sheet

001

Standby Liquid Control

AC

3312.01

Residual Heat Removal

3312.01E001

Residual Heat Removal Electrical Lineup

3312.01V001

Residual Heat Removal Valve Lineup

17d

3314.01

Standby Liquid Control

3314.01E001

Standby Liquid Control Electrical Lineup

3314.01V001

Standby Liquid Control Valve Lineup

10b

3503.01

Battery and DC Distribution

71111.04

Procedures

3503.01E001

Battery and DC Distribution Electrical Lineup

1893.04M102

707-781 Auxiliary: RHR A Pump and Heat Exchanger

Room Prefire Plan

1893.04M113

737 Auxiliary: RWCU Pump B Room Prefire Plan

5a

1893.04M130

Div 2 Swichgear Prefire Plan

5b

1893.04M510

737 Diesel Generator: Div 3 Diesel Generator & Day Tank

Room Prefire Plan

6c

1893.04M810

2 Service Building: Basement Prefire Plan

2c

Fire Plans

1893.04M811

737 Service Building: Ground Level Prefire Plan

2a

Miscellaneous

25-04

Fire Drill Scenario Information

03/18/2025

71111.05

Procedures

OP-AA-201-003

Fire Drill Performance

Miscellaneous

212.01F003

Control Rod Settle Record

3005.01

Unit Power Changes

3304.01

Control Rod Hydraulic and Control

3304.02

Rod Control and Information System

23d

71111.11Q

Procedures

ESG-LOR-005

Clinton Power Station Licensed Operator Training Simulator

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

Exercise Guide (OBE 5)

NF-AB-720

Control Rod Sequence Package Preparation, Review,

Revision, and Implementation

Miscellaneous

PRA CL 122A

Paragon RICT Report

03/03/2025

ER-CL-600-2001

Clinton RICT System Guidelines

71111.13

Procedures

OP-AA-108-118

Risk Informed Completion Time

4844324,

4848108,

4848401,

4848398,

4847904

Various Issue Reports Written Against the Condition

03/27/2025

Corrective Action

Documents

ARs 4836501,

4836506, and

4836549

Various Issue Reports Written Against the Condition

2/14/2025

Engineering

Changes

29951

Engineering Change Notice of Division I, II, and III

Diesel Engine Overspeed Trip Range

2/05/1996

466341

Division 1 DG Overspeed Trip Test Evaluation

03/06/2025

Engineering

Evaluations

466673

Support Change to Expand 9082.01 Tap 2 Operating Range

03/27/2025

1005.09

EOP/Off-Normal Performance Aid Matrix

9e

ESOMS

Electronic Shift Operations Management System

Narrative Logs

03/24/2025

ESOMS

Electronic Shift Operations Management System

Narrative Logs

01/28/2025

TS

Clinton Technical Specifications

01/28/2025

Miscellaneous

UFSAR

Clinton Updated Final Safety Analysis Report

01/28/2025

5065.05

Alarm Panel 5065 Annunciators - Row 5

34e

5067.02

Alarm Panel 5067 Annunciators - Row 2

71111.15

Procedures

9082.01

Offsite Source Power Verification

2c

9058.02

RCIC/ECCS Water Leg Pump Comprehensive Testing

9061.01

Fuel Pool Cooling Valve Operability

48e

9068.03

Primary Containment Recombiner and Valve Operability

Test

71111.24

Procedures

9080.03

Diesel Generator 1C Operability - Manual and Quick Start

Operability

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

9080.31

Diesel Generator Individual Engine Overspeed Trip Test and

Adjustment

4c

Work Orders

WO 5602483

Flex - 1FX01KB DG Functional

2/18/2025

EP-AA-112-500-

F-06

Transfer of Radiological Samples to Radiological

Laboratories

D

EP-AA-112-F-05

Environmental Sample Collection Guidelines

D

Miscellaneous

N-AN-EP-G-10a

Field Team Dispatch and Control for NON-RP Personnel

71114.06

Procedures

EP-AA-112-500-

F-01

Field Monitoring Team Checklist

J

Miscellaneous

NEI 99-02

Regulatory Assessment Performance Indicator Guideline

71151

Procedures

71151

Performance Indicator Verification

01/01/2025