May 23, 2019
SUBJECT:
DAVIS-BESSE NUCLEAR POWER STATION, UNIT 1NRC EMERGENCY
PREPAREDNESS INSPECTION REPORT 05000346/2019501
Dear Mr. Bezilla:
On April 18, 2019, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at your Davis-Besse Nuclear Power Station, Unit 1 and discussed the results of this inspection with Mr. B. Blair and other members of your staff. The results of this inspection are documented in the enclosed report.
The NRC inspectors did not identify any finding or violation of more-than-minor significance.
This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations, Part 2.390, Public Inspections, Exemptions, Requests for Withholding.
Sincerely,
/RA Gregory Roach Acting for/
David E. Hills, Acting Chief Operations Branch Division of Reactor Safety
Docket No. 05000346 License No. NPF-3
Enclosure:
Inspection Report 05000346/2019501
Inspection Report
Docket Number:
05000346
License Number:
Report Number:
Enterprise Identifier: I-2019-501-0015
Licensee:
FirstEnergy Nuclear Operating Co.
Facility:
Davis-Besse, Unit 1
Location:
Oak Harbor, OH 43449
Inspection Dates:
April 15, 2019, to April 18, 2019
Inspectors:
D. Chyu, Reactor Engineer
G. Hansen, Sr. Emergency Preparedness Inspector
S. Hedger, Emergency Preparedness Inspector
J. Rutkowski, Project Engineer
Approved By:
David E. Hills, Acting Chief
Operations Branch
Division of Reactor Safety
SUMMARY
The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting an Emergency Preparedness Inspection at Davis-Besse Nuclear Power Station, Unit 1 in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors. Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information. Findings and violations being considered in the NRCs assessment are summarized in the table below.
List of Findings and Violations
No findings or violations were identified.
Additional Tracking Items
None.
INSPECTION SCOPES
Inspections were conducted using the appropriate portions of the inspection procedures (IPs)in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html.
Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2515, Light-Water Reactor Inspection Program - Operations Phase. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.
REACTOR SAFETY
71114.01 - Exercise Evaluation
Inspection Review (IP Section 02.01-02.11) (1 Sample)
The inspectors evaluated the Biennial Emergency Plan Exercise. The exercise scenario simulated an event at the Davis-Besse Nuclear Power Station, Unit 1 that initiated with the declaration and notification of an Alert in response to damage to a safety system due to tornado activity in the vicinity of the plant on April 16, 2019. The scenario conditions simulated the escalation of the significance of the event, requiring the declaration of a Site Area Emergency, and then a General Emergency, as well as the development of Protective Action Recommendations that were communicated to the required state and local government agencies.
71114.08 - Exercise Evaluation Scenario Review
Inspection Review (IP Section 02.01 - 02.04) (1 Sample)
The inspectors reviewed and evaluated the proposed scenario for Biennial Emergency Plan Exercise on March 13,
OTHER ACTIVITIES - BASELINE
===71151 - Performance Indicator Verification
The inspectors verified licensee Performance Indicators submittals listed below:
Alert & Notification System Reliability (IP Section 02.14)===
January 2018 - December 2018
Drill/Exercise Performance (IP Section 02.12) (1 Sample)
January 2018 - December 2018
ERO Drill Participation (IP Section 02.13) (1 Sample)
January 2018 - December
INSPECTION RESULTS
No findings were identified.
EXIT MEETINGS AND DEBRIEFS
The inspectors verified no proprietary information was retained or documented in this report.
- On April 18, 2019, the inspectors presented the Emergency Preparedness inspection results to Mr. B. Blair and other members of the licensee staff.
DOCUMENTS REVIEWED
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
Corrective Action
Documents
CR-2017-04331
During the CANS Weekly Test conducted on 4/17/17,
all circuits are busy now messages were received
CR-2017-05010
2017 NRC Evaluated Exercise EP Drill Roll Up (Site Protection
Lessons Learned)
CR-2017-05030
EP-Drill: 2017 Evaluated Exercise TSC summary
CR-2017-06306
Continuing Trend in Site Protection for not Meeting Required
Timeline for ERO Pager Test
CR-2017-06382
NEI 99-01 Rev. 6 Bases document for HU3.2, CA6.1, and
SA9.1, Internal Flooding
CR-2017-06400
NEI 99-01 Rev. 6 Bases document information may result in
determination of Potential Loss of RCS, with RCS intact.
CR-2017-06973
Several individuals experienced issues calling into CANS
during June 27th call in drill.
CR-2017-07722
ERO on call responder did not call in for the weekly drill
CR-2017-08351
EP Drill 8-8-17 OSC performance summary
CR-2017-10357
EP Drill - Site protection performance
CR-2017-10537
EP Drill - Summary of dose assessment performance from
10/10/17 EP integrated drill
CR-2017-11279
MS-C-17-11-24: Emergency facility inventory issues
CR-2018-04604
EP Drill: May 15, 2018 Integrated Drill - TSC improvement
area for drill professionalism
CR-2018-04605
EP Drill: May 15, 2018, Integrated Drill - TSC improvement
area for critique performance
CR-2018-06805
Lessons learned when determining EAL applicability
CR-2019-01160
EP Drill - February 5, 2019, Integrated Drill Objective F.2 not
met for dose assessment
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
CR-2019-01161
EP Drill - February 5, 2019, Integrated Drill Objective F.5 not
met RMT air sampling
CR-2019-01162
EP Drill - February 5, 2019, Integrated Drill Objective F.10 not
met (RMT plume assessment)
CR-2019-01177
EP Drill - Failure to notify on-call ERO personnel within ten (10)
minutes of classification of an event that requires initial
activation
Procedures
Davis-Besse Nuclear Power Station Emergency Plan
DBRM-EMER-
1500B
Davis-Besse EAL Wallboards
NOP-LP-2001
Corrective Action Program
RA-EP-01500
Emergency Classification
RA-EP-01700
Alert
RA-EP-01800
Site Area Emergency
RA-EP-01900
General Emergency
RA-EP-02010
Emergency Management
RA-EP-02110
Emergency Notification
RA-EP-02220
Emergency Operations Facility Activation and Response
RA-EP-02240
Off Site Dose Assessment
RA-EP-02245
Protective Action Guidelines
RA-EP-02260
Radiological Controls in the DBAB
RA-EP-02320
Emergency Technical Assessment
Self-Assessments
SA-BN-2017-0547 May 2, 2017, Evaluated Exercise Report
05/22/2017
SA-BN-2018-1063 May 15, 2018, EP Integrated Drill Report
05/29/2018
SA-BN-2019-1344 September 25, 2018, Integrated Drill Report
01/31/2019
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
SA-BN-2019-1345 October 23, 2018, Integrated Drill Report
01/31/2019
SA-BN-2019-1381 February 5, 2019, EP Integrated Drill Performance
2/28/2019
SN-SA-2015-0037 May 5, 2015, Evaluated Exercise Self-Assessment
06/04/2015
71151
Miscellaneous
NOBP-LP-4012-54 Performance Indicator Data Sheets - Drill / Exercise
Performance
1st Quarter
2018 - 4th
Quarter 2018
NOBP-LP-4012-55 Performance Indicator Data Sheets - Emergency Response
Organization Participation
1st Quarter
2018 - 4th
Quarter 2018
NOBP-LP-4012-56 Performance Indicator Data Sheets - Alert Notification System
1st Quarter
2018 - 4th
Quarter 2018